Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D14-0296 - PIERCING PAGODA - KIOSK
PIERCING PAGODA 2800 SOUHCENTER MALL K-1042 D14-0296 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 9202470010 Permit Number: D14-0296 2800 SOUTHCENTER MALL UnitK-1042 Issue Date: 11/3/2014 Permit Expires On: 5/2/2015 Project Name: PIERCING PAGODA Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, PA, 92013 KARA KLINE 404 FURNACE ST, EMMAUS, PA, 18049 LAKEVIEW CONSTRUCTION INC PO BOX 308, PLEASANT PRAIRIE, WI, 53158 LAKEVCI072KC LESS THAN $5,000 Phone: (610) 657-6561 Phone: (414) 657-4222 Expiration Date: 1/13/2015 DESCRIPTION OF WORK: INSTALLATION OF 160 SF KIOSK Project Valuation: $4,500.00 Type of Fire Protection: Type of Construction: IIB Sprinklers: YES Fire Alarm: YES Fees Collected: $324.62 Occupancy per IBC: M Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2014 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: l l (. I hearby certify that I have read and :� ed this permit and know the same to be true and correct. All provisions of law and ordinances gov this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: //�j Print Name: /v/ / (< Date: r / V/41- This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: Post address on kiosk per approved Westfield standards. 9: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 12: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 13: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL CITY OF TUB-_ .ILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. Project No. Date Application Accepted: Date Application Expires: For olice use onl CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION ,foc King Co Assessor's Tax No.: t ?0 "l—QQ(,co Site Address: 2 S O 0 J e yip f 1 �' r1 e/-vt i c✓ /rv/( Suite Number: ?® 7 0 Floor: Lei Tenant Name: Pf e v . 11„� /- 0 q C / 3 if g New Tenant: ❑ Yes Al .. No PROPERTY OWNER Name: �t,Ti e r '4 1 p A Address G-/ City+-fsktrt` t., -/9 4•I Y 8' CONTACT PERSON - person receiving all project communication Name: kg, e 9 kill" c Address: '0, if. Pawl 9ce .T f City,rFr 14/ 4Gl.T State; A Zj 0le, Phooei 0 657 6 5 6/ Fax:: 8i 8 3 7 5. 3 0 2 5 Email: /. 9 gt RCO J g i, o e0 ` t o —, GENERAL CONTRACTOR INFORMATION Company Name: , Address: (® SL QCorpovofc DY Q0 0 Coy State Zi.3 i 5 3 "IC4.e.Q fro%% 4o 7 33`3 b Fax: Contr Reg No.:: 0/ 'rf 7 Fi 2 Exp Date: Tukwila Business License No.: D Im (,'jV 6� ARCHITECT OF RECORD Company Name: Ay. 1 frif j, ti 0 ii Architect Name: _. n rye- A/1' C 62-0 'tla Address: «5 1, Cvo-eg Rd q,3 City,_ o t;tt r� ✓vv[t State:A j0 Zip:9 / it 4 Phone3, if, it 15...2't0 0 Fax: if C PJI Email: ; rkgiZe Y 9 q rC v_ e ©fw.f ENGINEER OF RECORD /A Company Name: �1� Engineer Name: Address: City: State: Zip: r Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: fV, Address: City: State: Zip: H:\Applications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 1 of 4 BUILDING PERMIT INFORMAT 1— 206-431-3670 Valuation of Project (contractor's bid price): $ 5 0 0 Existing Building Valuation: $ 474 Describe the scope of work (please provide detailed information):�� fe-r l `c e eR�lJ )ifs. KIIO f K �ilp `-, %e_ Jqc c s1''z� .d7.1. Ce 1'4w'r [iron Will there be new rack storage? ❑ ....Yes ❑ ..No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1st Floor ' 0 0 0 l/ 0 E9 2 a ,� w //// 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) U7 PI 1e �s 1 Floor area of accessory dwelling: *For an Accessory dwelling, provide the following: / 4 0 Lot Area (sq ft): Floor area of principal dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 1" No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: C0Lee vL, 6y 144.0 f/ ❑ Sprinklers 0 Automatic Fire Alarm 0 None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. J)°v�u�r SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 PUBLIC WORKS PERMIT IN IMATION — 206-433-0179 Scope of Work (please provide detailed information): Ca11 before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila ❑ ...Water District # 125 ❑ .. Water Availability Provided Sewer District 0 .. Tukwila ❑ .. Sewer Use Certificate ❑... Highline ❑...Valley View ❑...Renton ❑ ... Sewer Availability Provided 0... Renton 0... Seattle Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34") ❑ .. Technical Information Report (Storm Drainage) ❑... Geotechnical Report ❑ .. Bond ❑... Insurance ❑... Easement(s) 0...Maintenance Agreement(s) Proposed Activities (mark boxes that applv): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - No Disturbance ❑ .. Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 ❑ .. Total Cut ❑ .. Total Fill cubic yards cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Permanent Water Meter Size (1) ❑ .. Temporary Water Meter Size (1) ❑ .. Water Only Meter Size ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) 0...Right-of-way Use - Profit for less than 72 hours 0...Right-of-way Use — Potential Disturbance El ... Work in Flood Zone ❑ ... Storm Drainage 0...Abandon Septic Tank ❑... Curb Cut 0...Pavement Cut 0...Looped Fire Line ❑ .. Sewer Main Extension Public ❑ .. Water Main Extension Public ❑...Grease Interceptor ❑... Channelization ❑...Trench Excavation 0...Utility Undergrounding WO # (2) " WO # (3) WO # (2) " WO # (3) WO # ❑ .. Deduct Water Meter Size Private 0 Private ❑ " WO# " WO# FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ .. Water ❑ .. Sewer 0 .. Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:Wpplications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 3 of 4 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Date: G% / 1 / Day Telephone:2-06-7 I- 9 9 I Mailing Address: 4 2-5 .4/74 1f rj ff' Spa If City State Zip H:\Applications\Forms-Applications 0n Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT I QUANTITY PermitTRAK PAID $202.22 D14-0296 Address: 2800 SOUTHCENTER MALL UnitK-1042 Apn: 9202470010 $202.22 DEVELOPMENT $192.80 PERMIT FEE R000.322.100.00.00 0.00 $188.30 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $9.42 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R3453 R000.322.900.04.00 0.00 $9.42 $202.22 Date Paid: Monday, November 03, 2014 Paid By: BEACH ELECTRIC Pay Method: CREDIT CARD 05549G Printed: Monday, November 03, 2014 12:35 PM 1 of 1 CSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PAID PermitTRAK $122.40 D14-0296 Address: 2800 SOUTHCENTER MALL Apn: 9202470010 $122.40 DEVELOPMENT $122.40 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R3063 R000.345.830.00.00 0.00 $122.40 $122.40 Date Paid: Friday, September 12, 2014 Paid By: BEACH ELECTRIC Pay Method: CASH Printed: Wednesday, September 17, 2014 2:45 1 of 1 AM CRWSYSTEMS CITY FORM NO 1 1912 ADOPTED BY DIVISION OF MUNICIPAL CORPORATIONS. Received of Date CITY OF TUKWILA TREASURER'S RECEIPT 47860 FOR By I-M*4 Dollars, TOTAL Lip DEPT {� OLYMPIC PRINTERS, INC. WHITE - Finance Dept. CANARY - Customer PINK - File a1 INSPECTION RECORD Retain a copy with permit INSP C ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: 'y.-y t E t. Q G \ D 4r Type of Inspection: t— I Q -A L— Address: Date Called: Special Instructions: ZIo``r t ... 1 0L/2. Date Wanted: 1‘ \ 5 (i -( in. -p.mK Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: "t C' t` evl k c.-Ak.„kcy iruAL Ifispe tor: t-S,, A Da`: II tI n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Cali to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Tve of Inspection: Address Suite #: � ) S.C.. M4tL Contact Person: Special Instructions: Phone No.: ,Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: /A- Date: / c`jf/(f Hrs.: l $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Address: Company Name: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 22"W x 28"H LED sign frame with clear acrylic cover, flush mounted Piercing chair (by other) Hinged ADA flip counter F-11 Carpet REVIEWED FOR CODE COMPLIANCE APPROVED k id OCT 0 7 2014 F Countertop o Cash Wrap City of Tukwila (BUILDING DIVISION 0-41/ 01, LED rope light around kick perimeter Front Isometric Black vinyl logo Showcase Exterior F-1 finish Showcase Interior F-3 finish 20"W x 9"H non -illuminated sign frame with clear acrylic cover, flush mounted LED Light Rails F-6 finish Ptin i Sign with raised letters F-9 finish (background) F-10 finish (letters), flush mounted Tall Pylon with spinner F-4 finish 1/4" thick laminated safety glass in F-4 finish extrusion 1/8" thick alumin ki e F-7 finishite..l�'u CITY OF TUKWILA SEP 12 2014 PERMIT CENTER Milford ENTERPRISES 450 Commerce Blvd. 215-538-2778 Quakertown, PA 18951 215-538-7026 Fax Scale: 1:64 Customer: Zales Description: 2014 Kiosks Westfield 10 x 16 File: Zales- PP- WF10x16 Kiosk Date: 10/15/2013 Rev: 7/16/2014 Drawn By: JT Sheet: 1 OF 7 Weight: This confidential document is the property of Milford Enterprises Inc and can not be reproduced either in full or in part without written approval of Milford Enterprises Inc. Revolving 3-sided showcase (by other) LED rope light around kick perimeter Rear Isometric Short Pylon F-4 finish 1/8" thick aluminum kick cover F-7 finish Showcase Exterior F-1 finish Showcase Interior F-3 finish 20"W x 9"H non -illuminated sign frame with clear acrylic cover, flush mounted Ivii1iord ENTERPRISES 450 Commerce Blvd. 215-538-2778 89 Quakertown, PA 18951 215-538-7026 Fax Scale: 1:64 Customer: Zales Description: 2014 Kiosks Westfield 10 x 16 File: Zales- PP- WF10x16 Kiosk Date: 10/15/2013 Rev: 7/16/2014 Drawn By: JT Sheet: 2 OF 7 Weight: This confidential document is the property of Milford Enterprises Inc and can not be reproduced either in full or in part without written approval of Milford Enterprises Inc. Hinged ADA flip counter (ADA Compliant with countertop at 34" A.F.F.) 26in 48in 16'-0" 48in 48in 24in 4 24.75in 37.125in ADA T-Shaped Space 7n 33in 2 2/3 L_-- 69.5in 29.118in • • 19in 26in 29.118in 24in ( 4 4 6 2/.? 10-5" 77in 26in l-- 24in Plan View 48in 48in 48in 8in 8in TOTAL WEDGE COUNT= 41 1/3 (does not include mini showcases that can be added or removed as needed) ri it ���rrr /% E0 �j ENTERPRISES 450 Commerce Blvd. 216538-2778 Quakertown, PA 18951 21b-538-7026 Fax Scale: 1:64 Customer: Zales Description: 2014 Kiosks Westfield 10 x 16 File: Zales- PP- WF10x16 Kiosk Date: 10/15/2013 Rev: 7/16/2014 Drawn By: JT Sheet: 3 OF 7 Weight: This confidential document is the property of Milford Enterprises Inc and can not be reproduced either in full or in part without written approval of Milford Enterprises Inc. 79in 1 3in 1 43in 40in 7in 86.099in 79in 24in Elevation A 85in Paroda 48in 7in 48in 48in 8in i-16in4-1 1.037in 79in 86.099in 63in 26in Elevation B 77in 24in None 12in 35in 79in 7in 26in Elevation C 37.125in 7in 33in 24in /r mid d ENTERPRISES 450 Commerce Blvd. 216-538-2778 Quakertown, PA 18951 215-538-7026 Fax Scale: 1:64 Customer: Zales Description: 2014 Kiosks Westfield 10 x 16 File: Zales- PP- WF10x16 Kiosk Date: 10/15/2013 Rev: 7/16/2014 Drawn By: JT Sheet: 4 OF 7 Weight: This confidential document is the property of Milford Enterprises Inc and can not be reproduced either in full or in part without written approval of Milford Enterprises Inc. 3 LED lights 5 LED lights 5 LED lights u 5 LED lights OVER HEAD LIGHTING PLAN 5 LED lights } 3 LED lights 3 LED lights NOTE: All arms are 46.5" long unless noted. (� J.,fjJj9j1f ENTERPRISES 450 Commerce Blvd. 215538-2778 Quakertown, PA 18951 216.ri38-7026 Fax Scale: 1:64 Customer: Zales2014 Description: Kiosks Westfield 10 x 16 File: Zales- PP- WF10x16 Kiosk Date: 10/15/2013 Rev: 7/16/2014 Drawn By: JT Sheet: 5 OF 7 Weight: This confidential document is the property of Milford Enterprises Inc and can not be reproduced either in full or in part without written approval of Milford Enterprises Inc. to power supply in comer to power supply in comer to power supply in comer IPog70,3. J LP4 FIRE EXTINGUISHER INSIDE LP2 PHONE Panel �°o'ri6op�'�F J r to power supply in comer —I to power supply in comer to power supply in comer —I ELECTRICAL PLAN Milford ENTERPRISES Scale: 1:64 Date: 10/15/2013 Drawn By: JT Customer: Zales Description: 2014 Kiosks Westfield 10 x 16 File: Zales- PP- WF10x16 Kiosk Rev: 7/16/2014 Sheet: 6 OF 7 Weight: 450 Commerce Blvd. 215-538-2778 Quakertown, PA 18951 215-538-7026 Fax This confidential document is the property of Milford Enterprises Inc and can not be reproduced either in full or in part without written approval of Milford Enterprises Inc. Notes: * 1/4" thick laminated safety glass is typical in all cases. * Kiosk is manufactured from Duraflake FR which is a Class 1 rated fire retardent particleboard. * Hinged ADA flip counter (ADA Compliant with countertop at 34" A.F.F.) * All showcases will have an internal fluted polypropylene cover. FINISH SCHEDULE F-1 Exterior Finish Wilsonart #7970K-18 High Line F-2 Sollid Surface Avonite #F1-9117 Kokoura F-3 Interior Finish Panolam #S-402 Cabinet Almond F-4 Metal Finish Wilsonart #6257 Satin Brushed Aluminum F-5 Metal Finish Powder coat RAL #1001 Beige F-6 Metal Finish Powder coat Bengal Silver #SL060401 P3 F-7 Metal Finish Satin Natural Aluminum F-8 Acrylic 1/8" Mirror F-9 Acrylic Acrylite #1 RK31 Ivory (2145) F-10 Sintra 3mm Black F-11 Flooring Expressway Carpet tiles- MS-01 Mustang Oats LIGHTING SCHEDULE LAMP LOCATION LAMP TYPE QTY WATTS 77" Showcase 46.2W LED 1 46.2 48" Showcase 30.8W LED 6 184.8 33" Showcase 19.3W LED 1 19.3 Corner Spinner 92.4W LED 2 184.8 Pylon Sign illumination 25.8W LED 2 51.6 22" x 28" LED Snapframe 10W LED 1 10 Overhead Light Rail (3 Light) 4.2W LED 3 12.6 Overhead Light Rail (5 Light) 7W LED 4 28 Rope Light (0.52W/ ft) LED 50' 26 TOTAL WATTS: 563.3 TOTAL AMPS: 4.69 ELECTRICAL NOTES: 1. ALL SHOWCASES AND CENTER ISLAND ELECTRICAL EQUIPMENT AND WIRING PERFORMED IN THE MANUFACTURING FACILITY ARE U.L. LISTED AS AN ASSEMBLY. U.L. FILE #E136514 2. ELECTRICAL PANEL BOX AND BREAKERS ARE SUPPLIED BY MANUFACTURER. 15 AMP BREAKERS ARE SPECIFIED TO BE USED BY MANUFACTURER. 3. U.L. LISTED 12-2 MC CABLE WITH GROUND WIRE TO BE USED IN KIOSK. 4. ALL WIRING IN CABINETS TO PASS THROUGH A PRECUT HOLE IN THE SIDES OF THE CABINETS AND FASTENED TO CABINET WITH MC MIDGET CABLE STRAPS. 5. ALL ON -SITE ELECTRICAL FINAL CONNECTION OF PANEL BOX TO BE DONE BY A LOCAL LICENSED ELECTRICAL CONTRACTOR. 6. LANDLORD WILL FURNISH EMPTY CONDUIT FOR TELEPHONE AND CONDUIT WITH (1) ELECTRICAL CIRCUIT TO SPACE. LP PANEL SCHEDULE QTY Description L-1 L-2 BKR LP1/LP3 2-POLE 20 AMP MAIN DISCONNECT WITH RETAINER CLIP 20 LP2 2 CASH WRAP QUAD 300 15 LP4 10 CORNER DUPLEX OUTLETS/ POWER SUPPLIES 1500 15 LP5 15 LP6 15 LP7 15 LP8 15 LEG TOTALS 300 1500 AMP TOTALS 2.5 12.5 Milford ENTERPRISES 450 Commerce Blvd. 215-538-2778 Quakertown, PA 18951 215-538-7026 Fax Scale: 1:64 Customer: Zales Description: Kiosk- Piercing Pagoda File: Zales- PP- WF10x16 Kiosk Date: 10/15/2013 Rev: 7/16/2014 Drawn By: JT Sheet: 7 OF 7 Weight: This confidential document is the property of Milford Enterprises Inc and can not be reproduced either in full or in part without written approval of Milford Enterprises Inc. VV IISUI IdE L Technical Data Sheet PRODUCT NAME Wilsonart® Decorative Metals MANUFACTURER Wilsonart LLC 2400 Wilson Place P.O. Box 6110 Temple, TX 76503-6110 Toll -Free: 800-433-3222 Website: www.wilsonart.com PRODUCT OVERVIEW The Wilsonart® Decorative Metals collection offers sophisticated design options for decorative metal applications. Wilsonart® Decorative Metals are designed for interior use only and have a wide range of vertical, decorative signage, and accent banding applications. Common design applications are retail facilities, hotel and office lobbies, theaters, restaurants, and casework designs. This design line utilizes Galvalume® Steel and Aluminum for base metals. The unique difference from standard decorative metal designs is the wide range of color, tone, texturing, and sheen options. Colors include copper, silver, bronze, gold, grey, and blue -grey. Strips, swirls, and brush stroke looks add to the design options. Tonal variations in the Artisan Group and Metro Collection complete a full design palette. Final finish (sheen) for surfaces ranges from matte to high gloss. Standard metal sheet width is 48 inches. Sheets are available in 96 inch and 120 inch lengths. Certain patterns are limited to 96 inch lengths; refer to the Wilsonart Guide Specification 05 7000 - Decorative Metals for a listing of these patterns. The full line of aluminum Decorative Metals is available with an optional phenolic backer for flat surface (non -formed) applications. The Galvalume® Steel Decorative Metal product is not available with a phenolic backer. Wilsonart® Decorative Metals are bonded to installation substrates with Wilsonart® 950/951 and Wilsonart® 800/801 Contact Adhesives. TECHNICAL DATA Wilsonart® Decorative Metals are Class 1/A rated according to ASTM E 84 test procedures. SUSTAINABLE DESIGN LEED® 2009 potential credits can be obtained in the Commercial Interiors category for the following: • MR 4 Recycled Content • IEQ 4.1 Low -Emitting Materials • IEQ 4.4 Low -Emitting Materials Wilsonart® Decorative Metals are UL GREENGUARD Gold Certified for low chemical emissions. CERTIFICATIONS Wilsonart® Decorative Metals have achieved the following: UL 2818 GREENGUARD Gold Certified for low chemical emissions. NSF 51 Food Zone and FDA food contact compliance. FABRICATION Refer to Wilsonart Decorative Metals Fabrication Manual for detailed information. WARRANTY Wilsonart offers a 1 year Limited Warranty against material defects. Refer to the Wilsonart website for complete warranty information. CARE AND MAINTENANCE Refer to the Wilsonart website for care and maintenance instructions. CUSTOMER SERVICE For samples, literature, technical assistance, or questions, please call the toll -free Hotline at 800-433-3222, Monday through Friday, 8:00 am to 5:00 pm, CST or visit our website. Wilsonart® Decorative Metals Page 1 CI VI/ IISUI Id( L Technical Data Sheet REFERENCE SOURCES ASTM International www.astm.org Construction Specifications Institute (CSI) MasterFormat® Edition Numbers & Titles www.csinet.org/masterformat UL Environment business unit; Underwriters Laboratories, Inc. www.ul.com/environment UL GREENGUARD Indoor Air Quality Certification Programs www.GREENGUARD.org U.S. Green Building Council LEED® Green Building Rating System www.usgbc.org Wilsonart Guide Specifications: 05 7500 - Decorative Metals www.wilsonart.com FILE ORGANIZATION File under the CSI MasterFormat® classification system. A common section number and title is: 05 7000 - Decorative Metals Wilsonart® Decorative Metals Page 2 Duraflake® FR Flakeboard PARTICLEBOARD Passion for Panels TM Flakeboard Duraflake® FR particleboard is the preferred solution for applications where fire safety is required. Duraflake® FR particleboard is a UL® approved, Class A/Class 1-rated fire retardant panel, which makes it suitable for interior, non-structural use when building codes and public safety requirements are important. Architects specify Duraflake® FR particleboard in restaurants, schools, hospitals, hotels, malls, airports, offices and public buildings. Duraflake®FR Particleboard Specifications (Albany, OR) APPLICATIONS • Elevator Cabs • Passenger Boarding Bridges • Architectural Woodwork • Wainscoting • Display Panels • Door Components • Furniture • Fixtures • Commercial Case Goods • Shelving • Cabinets • Countertops STORAGE AND HANDLING Duraflake® FR particleboard should never be stored or used outdoors. The indoor storage area should be clean, dry, well - ventilated, and free of dust, dirt or particles that could contaminate the particleboard. Store flat on stickers on a level, hard, dry surface. Constant relative humidity and temperature should be maintained. Before use, allow to stabilize to the same conditions as are expected after the panel is installed. Condition 48 to 72 hours prior to lamination. For more information, see Composite Panels Association Technical Bulletin: Storage and Handling of Particleboard and MDF. Excellent Machining and Low Tool Wear Consistent manufacturing processes and a well-balanced surface - to -core construction result in an easy -to -machine panel when sawing and routing. Wide Range of Products and Sizes Flakeboard Duraflake® FR particleboard is stocked at distributors across North America. Stocked lengths are 6', 8', 10' and 12'. Thicknesses range from 3'8" to 1'h", or metric units within this range. Standard widths range from 3' to 5'. Custom dimensions may be ordered up to 6' wide. Cut -to -size is also available. Finishes and Decorative Laminates Flakeboard Duraflake® FR particleboard is available from secondary manufacturers with a wide variety of wood veneers, high- and low-pressure laminates and thin roll laminates. PRODUCT USES FEATURES AND BENEFITS Strength and Dimensional Stability Douglas fir and other western softwood particles have proven dimensional stability, low linear expansion, and low thickness swell. Multi -layer construction of Duraflake® FR particleboard adds to the strength and stability of the finished product. Smooth Finishing Surface Fine particle distribution results in a smooth surface for laminating and finishing. Flakeboard Duraflake® FR particleboard is a high -quality, interior, non-structural panel made from Douglas fir and other western softwood particles, fire retardant chemicals and special formulas of resins and waxes. The flame retardant is distributed evenly throughout the panel, making it an effective Class A/Class 1 fire retardant particleboard. It can be drilled, routed, bullnosed, beveled and precision -machined without affecting the flame spread rating. Limitations • Duraflake® FR particleboard should be specified for interior use only and is not intended for use in exterior applications or damp conditions. Duraflake®FR Particleboard Specifications (Albany, OR) USAGE NOTES • Some laminates applied to Duraflake® FR particleboard may change the flame spread rating. • Standard available woodworking glues have been successfully used in lamination. However, some adhesives may have compatibility problems with the chemical system used to manufacture Duraflake® FR particleboard. Any adhesive should be tested for compatibility with the chemical system in Duraflake® FR particleboard prior to full-scale gluing. Questions should be directed to the glue supplier. • When using Duraflake® FR particleboard in wall systems, an integral vapor barrier must be a properly installed component of the wall in any of the following conditions: - The wall has an exterior side - The wall separates spaces conditioned unequally • Joints between panels to be designed to accommodate movement of up to .40 percent. Splined or articulated joints for reveals per AWI Section 500, 500A-G-4 `Joints and Transitions" or similar is suggested. TECHNICAL DATA Applicable Standard Tests • ASTM E 84 Standard Test for Surface Burning Characteristics of Building Materials • ASTM C 236 Guarded Hot Box Test • UL 723 Test for Surface Burning Characteristics of Building Materials Building Codes • ICC - International Code Council - 2000, 2003, 2006 International Building Code • NFPA - National Fire Protection Association - NFPA 101 Life Safety Code - NFPA 5000 Building Construction Safety Code Agency Approvals • California State Fire Marshall 2660-1627:100 • City of NewYork MEA 177-78-M • City of Los Angeles RR 24811 • City and County of San Francisco 6260W34.1B • City and County of Denver M-88-46 Underwriter's Laboratories, Inc. Classified Wood Particleboard Surface Burning Characteristics, UL 723 (Based on 100 for Untreated Red Oak) Flame Spread 20 Smoke Developed 25 See UL Classified Building Materials Index. Listed under Wood Particleboard. Thermal Conductivity (k) and Thermal Resistance (1 /k = R)' Thickness (in) 3'8 1/2 3/4 1 k= 0.54 0.62 0.55 0.69 R= 1.85 1.61 1.82 1.45 1.1i and k values obtained using ASTM C 236 "Thermal conductance and transmittance of built-up wall sections by means of thc'Guarded Hot Box' in t sus conducted by Northwest Testing Laboratories." Properties Grade Duraflake® FR Particleboard Thickness' (in) 318-3'4 13/16- 11/2 Specification Class A/Class 1 Flame Spread Class A/Class 1 Flame Spread Density (pcf) 47 - 50 44-47 MOR (psi) 1,600 1,600 MOE (psi) 300,000 250,000 Internal Bond (psi) 80 60 Face Screw Hold (Ib) 250 250 Edge Screw Hold (Ib) 225 175 Linear Expansion (%) 0.40 0.35 Thickness Tolerance (in) +/- 0.005 +/- 0.005 Length and Width (in) +/- 1/16 +/- 1'16 Squareness (in) +/- 1/8 +/- lie I. Metric thickness available. The above properties arc based on averages of normal production.Testing for conformance to the above specifications must be done in accordance with procedures in the American National Standard for Particleboard (ANSI A208.1-1999). Warning: Particleboard is manufactured with urea -formaldehyde resin and may release formaldehyde in low concentrations. Formaldehyde can cause temporary eye and respiratory irritation and may aggravate respi- ratory conditions or allergies. Proper ventilation will reduce the risk of such problems. As with any building project, always wear proper eye, ear, and breathing protection and follow local building codes. A Material Safety Data Sheet is available upon request. P.O. Box 428, Albany, OR 97321 888.650.6302 or 541.928.3341, 541.928.4116 (fax) www flakeboard.com ENVIRONMENTALLY PREFERABLE PRODUCT CPA 2-06 Specifcation • Contains 100% Recycled/Recovered Wood Content • Conforms to both ANSI A208.1 Table A and HUD 24 CFR Part 3280 Formaldehyde Emission Requirements for Particleboard AN. COMPOSITE PANEL ASSOCIATION SECTION 06 05 60 DECORATIVE PLASTIC LAMINATE PART1 - GENERAL 1.1 SUMMARY A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section. B. Section Includes: 1. [Standard decorative laminate] [Solid color decorative laminate] [Metal laminates] [Fire rated decorative laminates] [Chemical resistant decorative laminate] [Wood surfacing decorative laminate] surfacing for finishing [casework] [millwork] [countertops] [toilet partitions] [walls] [<add surfaces to be finished>] as indicated, including accessories and trim needed for a complete installation. 1.2 RELATED WORK A. Work of this section is related to work specified in the following sections: 1. Division 6 Section "Finish Carpentry". 2. Division 6 Section "Interior Architectural Woodwork". 3. Division 10 Section " Toilet Partitions". 4. Division 12 Section ["Institutional Casework"] ["Residential Casework"] ["Laboratory Casework"]. 5. Division 16 Section ["Plumbing Fixtures"]. B. Allowances: Furnish the following under the allowances indicated as specified in Division 1 Section "Allowances": 1. [<Insert work to be included under an allowance>.] C. Alternates: Refer to Division 1 Section "Alternates" for description of Work in this Section affected by alternates. 1.3 REFERENCES A. Reference Standards: In addition to requirements, comply with applicable provisions of following for design, materials, fabrication, and installation of component parts: 1. NEMA LD3-1995. 1.4 SUBMITTALS A. Product Data: Manufacturer's technical literature for decorative plastic laminate material, adhesive for bonding plastic laminate, miscellaneous accessories and related components. B. Samples: 1. Decorative plastic laminates, 5 by 7 inches (125 by 175 mm), for each type, color, pattern, and surface finish [with 1 sample applied to core material] [and specified edge material applied to 1 edge]. C. Product [Schedule]: For decorative plastic laminate materials. [Use same designations indicated on Drawings.] Formica Guide Specifications DECORATIVE PLASTIC LAMINATE 06 05 60 - 1 27 March 2006 D. Informational Submittals: Submit following packaged separately from other submittals: 1. Manufacturer's written handling, storage and installation instructions. 1.5 QUALITY ASSURANCE A. Fabricator/Installer Qualifications: Company specializing in fabricating and installing decorative plastic laminate finished work with a minimum 3 years experience. B. Source Limitations: Obtain decorative plastic laminate materials through one source from a single manufacturer. C. Fire -Test -Response Characteristics: Provide decorative plastic laminate with the following surface - burning characteristics as determined by testing identical products per ASTM E 84 by UL or another testing and inspecting agency acceptable to authorities having jurisdiction: 1. Flame -Spread Index: 25 or less. 2. Smoke -Developed Index: 450 or less. D. Mockups: Build mockups to [verify selections made under sample Submittals and to demonstrate aesthetic effects][and qualities of materials and execution][set quality standard for fabrication and installation]. 1.6 DELIVERY, STORAGE AND HANDLING A. Deliver, store, handle, and protect materials in accordance with manufacturer's written instructions. 1. Provide protective coverings of suitable material. Take special precautions at corners. 1.7 SEQUENCING A. Coordinate sizes and locations of plumbing, cut-outs and other related Work specified in other Sections to ensure that interior architectural woodwork can be supported and installed as indicated. PART 2 - PRODUCTS 2.1 PRODUCTS AND MANUFACTURERS A. Acceptable Manufacturer: Formica Corp., 10155 Reading Road, Cincinnati, OH. 45241 (513-786-3400). 2.2 MATERIALS AND COMPONENTS A. Decorative Plastic Laminate: Manufacturers standard and custom decorative surface papers with melamine resins, bonded under heat and pressure to kraft paper backing sheet with phenolic resins. B. Standard Decorative Laminate — General Purpose Type [Decorative Laminate] [Cabinet Liner] [Backing Sheet]: 1. Grade: [Grade 10, HGS] [Grade 51, HGS] [Grade 12, HGP] [Grade 52, HGP] [VGP] [CLS] [BKL] [BKH]. 2. Thickness: [.048 Inches (1.2mm)] [.050 Inches (1.2mm)] [.039 Inches (1.0mm)] [.028 Inches (0.7mm)] [.020 Inches (0.5mm)] [.048 Inches (1.2mm)]. 3. Surface burning characteristics in accordance with ASTM E84. 4. Finish: 5. Colors and Patterns: [As indicated by manufacturer's designations] [Match Architect's samples] [As selected by Architect from manufacturer's full range]. C. Solid Color Decorative Laminate: 1. Grade: [Grade 41, HCS] [Grade 43, HCS]. 2. Thickness: [.051 Inches (1.3 mm)] [.062 Inches (1.6 mm)]. 3. Surface burning characteristics in accordance with ASTM E84. Formica Guide Specifications DECORATIVE PLASTIC LAMINATE 06 05 60 - 2 27 March 2006 4. Finish: 5. Colors and Patterns: [As indicated by manufacturer's designations] [Match Architect's samples] [As selected by Architect from manufacturer's full range]. D. Fire Rated [Decorative Laminate] [Cabinet Liner] [Backing Sheet]: 1. Grade: [HGF] [VGF] [BLF] [BCF]. 2. Thickness: [.048 Inches (1.2 mm)] [.032 Inches (0.8mm)] [.028 Inches (0.7mm)]. 3. Surface burning characteristics in accordance with ASTM E84 or UL723. 4. Finish: 5. Colors and Patterns: [As indicated by manufacturer's designations] [Match Architect's samples] [As selected by Architect from manufacturer's full range]. E. Chemical Resistant Decorative Laminate: 1. Grade: [Grade 25, "Post Forming Grade] 2. Thickness: 3. Surface burning characteristics in accordance with ASTM E84. 4. Finish: 5. Colors and Patterns: [As indicated by manufacturer's designations] [Match Architect's samples] [As selected by Architect from manufacturer's full range]. F. Metal Laminate: 1. Grade: [Grade 82] [Grade 83] [Grade 84] [Grade 85] [Grade 86]. 2. Thickness: [.025 Inches (0.7mm)] [.030 Inches (.08mm)] [.040 Inches (1.0mm)] [.050 Inches (1.3mm)] 3. Sheet Size: [4 Foot x 8 Foot] [4 Foot x 10 Foot] 4. Surface burning characteristics in accordance with ASTM E84. 5. Finish: 6. Colors and Patterns: [As indicated by manufacturer's designations] [Match Architect's samples] [As selected by Architect from manufacturer's full range]. G. Wood Surfacing Decorative Laminate: 1. Grade: [ALN] [ALP] [PREFINISHED]. 2. Sheet Size: [4 Foot x 8 Foot] [3 Foot x 8 Foot] 3. Colors and Patterns: [As indicated by manufacturer's designations] [Match Architect's samples] [As selected by Architect from manufacturer's full range]. H. Edges: [Grade HGS] [PVC tape, 0.018-inch (0.460-mm) minimum thickness, matching laminate in color, pattern, and finish] [PVC T-mold matching laminate in color, pattern, and finish] [PVC edge banding, 0.12 inch (3 mm) thick, matching laminate in color, pattern, and finish]. 2.3 ACCESSORY MATERIALS A. Adhesive for Bonding Plastic Laminate: [Unpigmented contact cement] [Contact cement] [PVA] [Urea formaldehyde] [Resorcinol]. Formica Guide Specifications DECORATIVE PLASTIC LAMINATE 06 05 60 - 3 27 March 2006 o PART 3 - EXECUTION 3.1 EXAMINATION AND PREPARATION A. Examine surfaces for conditions that would adversely affect decorative plastic laminate surfacing. 3.2 INSTALLATION A. General: Install decorative plastic laminate in accordance with manufacturer's written installation instructions, approved Submittals and requirements of [Division 6 Section "Finish Carpentry"] [Division 6 Section "Interior Architectural Woodwork"] [Division 10 Section " Toilet Partitions' [Division 12 Section [`institutional Casework"] ["Residential Casework'] ["Laboratory Casework']]. 1. Provide templates and rough -in measurements. 3.3 CLEANING AND PROTECTION A. Cleaning: 1. Clean decorative plastic laminate surfaces in accordance with manufacturer's instructions. B. Protection: 1. Do not permit construction near unprotected surfaces. END OF SECTION Formica Guide Specifications DECORATIVE PLASTIC LAMINATE 06 05 60 - 4 27 March 2006 Pionite° Standard Laminate Technical Bulletin Product Identification Three standard grades of Pionite laminate are suitable for most applications. General Purpose Type G48 is most often used in horizontal applications where high impact resistance and a durable, decorative surface is required. Postforming Type F39 is designed for manufacturing countertops and other horizontal surfaces where the laminate may be heated and rolled over the substrate edge to eliminate seams. Type F28 is designed for applications where impact resistance is less critical. Type F28 can also be postformed. Product Composition High pressure laminate is manufactured in a flat press by combining decorative papers saturated in melamine resin with phenolic -impregnated kraft layers at pressures exceeding the NEMA specification of 750 psi (5.17 MPa) and temperatures approaching 300° F (150 °C). The panels are trimmed to size and the backs are sanded to facilitate bonding. The thickness of the laminate is determined by the number of kraft layers used. The laminating process combines the durability of melamine resins with the aesthetics of decorative papers creating a surfacing material that has been the standard for well over forty years. Product Description Standard Nominal Sizes Type Thickness Width Length Colors G48 (in) (mm) 0.048 30, 36, 48, 60 1.2 762, 914, 1219, 1524 96, 120, 144 2438, 3048, 3658 All Solids, Patterns and Woodgrains F39 (in) (mm) 0.039 30, 36, 48, 60 1.0 762, 914, 1219, 1524 96, 120, 144 All Solids, Patterns 2438,3048,3658 and Woodgrains F28 (in) (mm) 0.028 30, 36, 48, 60 0.7 762, 914,1219,1524 96, 120, 144 All Solids, Patterns 2438, 3048, 3658 and Woodgrains Finish Options Code Finish Description N Suede Low gloss, textured finish, 12± 3 gloss units. G Goss A high gloss, smooth finish, 100 ± 10 gloss units. J Crystal Fine pebble grained finish with a medium gloss, 15 ± 3 gloss units. H Hi-Brite Smoothly textured furniture finish, 25 ± 5 gloss units. C Soft Leather A finely grained leather finish, 14 ± 3 gloss units. Available in widths of 48" and 60" only. L Embossed Deeply embossed leather finish, 5 ± 1 gloss units. Leather Manufactured in Limited Sizes. W Embossed Slate Deeply embossed slate finish, 7 ± I gloss units. Manufactured in Limited Sizes. Z Ashwood A fine wood finish with a cathedral grain, 18 ± 3 gloss units. NOTE: Gloss units measured with a 60 degree gloss meter. Typical Uses Pionite standard laminate is designed for either horizontal, vertical, or postforming applications. This laminate is seen on countertops, tables, vanities, interior doors, cabinets, contract fumiture, and retail store fixtures. Pionite Decorative Surfaces • A Subsidiary of Panolam Industries International Inc. One Pionite Road • Auburn, ME 04211-1014 • Phone: 800-PIONITE (746-6483) • 207-784-9111 • Fax: 207-784-0392 • www.pionite.com Fabrication Tips When working with Pionite, these techniques will produce a quality application. 1. Proper conditioning of the laminate, substrate, and backing sheet minimizes possible warping, shrinking, or expansion of assembled panels. Ideally, all components should be conditioned at 70° F to 75° F (21 °C to 25 °C) and 45 to 50 percent relative humidity for 48 hours prior to assembly. 2. Always bond laminate to a suitable substrate such as medium to high density fiberboard, particleboard, or metals. It should not be glued directly to plaster walls, gypsum wallboard, or concrete. 3. Recommended adhesives include solvent or water -based contact cement, white glue (PVA), epoxy, and hot melt glue. Consult your adhesive supplier for specific application requirements. 4. The use of a backing sheet is recommended to minimize warpage. The thickness of the backing sheet should be relatively equal to the thickness of the decorative laminate on the face of the assembly. Technical Information Physical Properties TEST NEMA TYPICAL LD 3-1995 PIONITE Test VALUES Method G48 5. All saw blades and router bits used for cutting should be carbide tipped. Feed rate should be slow and tool speed should be high. To minimize the development of surface scratches caused by router bits, lubricating the laminate edge with a wax stick is recommended prior to tooling. 6. All edges of laminate should be filed smooth with file direction towards substrate to help prevent stress cracks and to minimize chipping. 7. Inside corners of cutouts for electrical outlets, sinks, etc., should have a minimum radius of 1/8" (3 mm) and be filed smooth. This reduces the likelihood of stress cracks. 8. When nails or screws must be used, it is advisable to first drill an oversized hole through the laminate. This reduces the likelihood of stress cracks. 9. See Pionite Postforming Technical Bulletin for postforming application tips. 10. All laminate is intended for interior use only, and should not be exposed to extreme humidity, continuous sunlight, or temperatures above 275° F (135 °C) for extended periods of time. NEMA STD. TYPICAL HGS PIONITE VALUES F39 NEMA STD. TYPICAL HGP PIONITE VALUES F28 NEMA STD. VGP Thickness (in.) (mm) 0.048 ± 0.003 0.048 ± 0.005 0.039 ± 0.005 0.039 ± 0.005 0.028 ± 0.003 0.028 ± 0.004 1.2 ± 0.08 1.2 ± 0.12 1.0 ± 0.08 1.0 0.12 0.711 ± 0.076 0.7 ± 0.1 Appearance 3.1 Complies Complies Complies Light Resistance 3.3 Slight effect Slight effect Slight effect Slight effect Slight effect Slight effect Cleanability Stain 1-10 Stain 11-15 3.4 13 No effect No effect 20 (max) No effect 13 20 (max) 8 20 (max) No effect No effect No effect No effect Moderate effect No effect Moderate effect No effect Moderate effect Boiling Water Resistance 3.5 No effect No effect No effect Slight effect No effect Slight effect High Temperature Resistance 3.6 No effect Slight effect No effect Slight effect No effect Slight effect Ball Impact Resistance Radiant Heat Resistance Dimensional Change Machine Direction Cross Direction Room Temperature Dimensional Stability Machine Direction Cross Direction (in.) (mm) (sec) 3.8 55 1397 3.10 200 50 (min.) 1270 (min.) 125 (min.) 35 889 165 30 (min.) 30 762 (min.) 762 20 (min.) 508 (min.) 100 (min.) 155 80 (min.) (%) (%) (%) (%) 3.11 0.25 0.70 3.12 .15 0.50 (max.) 0.90 (max.) .5 .40 .8 0.40 0.80 .16 .48 1.3 0.40 0.80 .18 .37 1.3 Wear Resistance (cycles) Formability (in) (mm) 3.13 700 400 (min.) 3.14 Not applicable Not applicable Not applicable Not applicable Blister Resistance (sec) 3.15 80 Not applicable 700 9/16 14 65 400 (min.) 700 5/8 (min.) 7/16 16 (min.) 11 400 (min.) 1/2 (min.) • 13 (min.) 55 (min.) 50 40 (min.) Pionitex Decorative Surfaces • A Subsidiary of Panolam Industries International Inc. One Pionite Road • Auburn, ME 04211-1014 • Phone: 800-PIONITE (746-6483) • 207-784-9111 • Fax: 207-784-0392 • www.pionite.com A n .? Fire Test Data High pressure decorative laminate is frequently used in installations governed by local fire codes. Buming characteristics of laminate are greatly influenced by the adhesive and substrate utilized. Listed below are typical flame spread index and smoke developed values for Pionite standard grade laminate. When specifying Class I or A rated laminate, refer to Pionite Fire Rated Technical Bulletin. ASTM E-84/UL723 "Standard Test Method for Surface Burning Characteristics of Building Materials" Type Sample Flame Configuration Spread Index Smoke Developed Values G48 Unbonded F39 F28 35 40 35 80 70 35 G48 F39 F28 Bonded* to Inorganic Cement Board 55 55 35 85 105 40 G48 Bonded* to 5/8" 160 F39 235 F28 160 Particleboard 110 140 160 G48 F39 F28 Bonded* to 5/8" Fire Rated Particleboard 95 110 80 95 130 75 *Bonded with Pioneer P19NF contact cement. All work should be designed, assembled, and installed in compliance with pertinent local fire codes. Codes and Certifications 1. U.S. Federal Motor Vehicle Safety Standard #302 "Flammability of Interior Materials." Pionite Type G48, F39, and F28 comply. 2. The City of New York, Dept. of Buildings, Materials and Equipment Acceptance Division approval codes are as follows: G48 - MEA 205-93-M F39 - MEA 206-93-M F28 - MEA 208-93-M 3. NSF -International Standard 35, "Laminated Plastics for Surfacing Food Service Equipment." Pionite Type G48, F39, and F28 comply. 4. American National Standards Institute/National Electrical Manufacturers Association (ANSI/NEMA), LD3-1995, "High - Pressure Decorative Laminate." Pionite Type G48, F39, and F28 comply. 5. MIL-P-17171E(SH), "High Pressure Decorative Laminate." Pionite G48 complies with Type I. 6. U.S. Federal Specification L-P-508H, "Plastic Sheet, Laminated, Decorative and Nondecorative." Pionite Type G48, F39, and F28 comply. 7. International Organization for Standardization, ISO-4586, "Decorative High Pressure Laminates (HPL)." Pionite Type G48, F39, and F28 comply. Care and Maintenance Pionite decorative laminate provides a durable surface that is easy to maintain using ordinary care. To maintain the laminate's lasting beauty, cleaning with a solution of warm water and liquid dishwashing detergent is all that should be required in most cases. Stains may be removed with most non-abrasive household cleaners such as FORMULA 409®, FANTASTIK®, GLASS PLUS®, or WINDEX WITH AMMONIA D®. Light scrubbing with a soft bristled brush may be necessary to remove stains from the depth of the structure on some textured surfaces. If the stain persists, use a paste of baking soda and water and apply with a soft bristled brush. Light scrubbing for 10-20 strokes should remove most stains. Although baking soda is a low abrasive, excessive scrubbing or exerting too much force may damage the decorative surface, especially if it has a gloss finish. Stubborn stains that resist any of the above cleaning methods may require the use of undiluted household bleach. Apply the bleach to the stain and let stand no longer than 1 1/2 minutes. Rinse thoroughly with warm water and wipe dry. This step may be repeated if the stain appears to be going away and the color of the laminate has not been affected. WARNING: Prolonged exposure of the laminate surface to bleach will cause discoloration. Many commercially available products contain substances that may damage or discolor a laminate surface. ABRASIVE CLEANERS SHOULD NOT BE USED. Particular care should be used with any products labelled CAUTION or WARNING. Any questions or concems should be referred to the product's manufacturer or call 1-800-PIONITE. Do not allow harsh materials to remain in contact with the laminate surface. Examples of these are as follows: Toilet bowl cleaners Hydrogen Peroxide Oven cleaners Drain cleaners Metal cleaners and polishes Chlorine bleach Coffee pot cleaners Hard water stain removers Fruit and berry juice Tub and tile cleaners Formula 409 is a registered trademark for The Clorox Company of Oakland, CA 94612; Glass Plus and Fantastick are registered trademarks for The Dow Chemical Company of Indianapolis, IN 46268-0511; Windex is a registered trademark for S.0 Johnson & Sons INC. of Racine, WI 53403-5011 Pionite® Decorative Surfaces • A Subsidiary of Panolam Industries International Inc. One Pionite Road • Auburn, ME 04211-1014 • Phone: 800-PIONITE (746-6483) • 207-784-9111 • Fax: 207-784-0392 • www.pionite.com t ea Manufacturing Headquarters Pionite® Decorative Surfaces One Pionite Rd. P.O. Box 1014 Auburn, ME 04211-1014 (207) 784-9111 800-PIONITE (746-6483) www.pionite.com A Subsidiary of Panolam Industries International, Inc. Printed on recycled paper Limited Warranty Subject to the limitations set forth below, Pionite® Decorative Surfaces express- ly warrants that our products are reasonably free of defects in material and work- manship, and when properly handled and fabricated will conform, within accepted tolerances, to applicable manufacturing specifications as set forth in our technical brochure. This warranty shall extend to the original buyer for a period of twelve (12) months from the date of shipment of this product by Pionite® Decorative Surfaces, and shall not be assignable by the original buyer. This warranty does not cover damage resulting from accident, misuse, alteration, abuse or lack of reasonable care. Due to the variety of uses and applications to which this product may be put, and because the manufacturer has no control over the end products fabricated, the warranty set forth above is exclusive and in lieu of all other warranties, express or implied, in fact or by operation of law or otherwise, or arising by course of dealing or performance, custom or usage in the trade, including, without limitation, the implied warranties of fitness for a particular purpose and merchantility, and Pionite® Decorative Surfaces shall have no obligation or liability to any person or entity in connection with or arising from the furnishing, sale, instal- lation or repair, use or subsequent sale of any product supplied by i1. The buyer's sole and exclusive remedy for any noncompliance with the express warranty set forth above shall be limited to repair or replacement of the defective product, or, in the event that repair or replacement is not feasible, return of the product and refund of the purchase price. Under no circumstances shall the manufacturer be liable in excess of the purchase price of this product, in either tort or contract or otherwise, for any loss, damage or injury in connection with or arising from the purchase, use, or inability to use this product, or for any special, indirect, collateral, incidental, consequential or exemplary damages such as, but not limited to, loss of anticipated profits or other economic loss. Because some states do not allow the exclusion or limitation of incidental or consequential damages, this limitation may not apply to you. Retaining all documentation after purchasing laminate will significantly expe- dite claim resolution. SMPTB000-001 12/00 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0296 DATE: 09/12/2014 PROJECT NAME: PIERCING PAGODA SITE ADDRESS: 2800 SOUTHCENTER MALL, K-10/6 10E42 X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: �s ( gm-17 --` u Building Division gm N/i- �t Public Works Fire Prevention Planning Division ig Structural Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 09/16/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required n (corrections entered in Reviews) Notation: _'1_ Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 10/14/14 ❑ REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 LAKEVIEW CONSTRUCTION ITTt' Page 1 of 2 Washington State Department of Labor & Industries LAKEVIEW CONSTRUCTION INC Owner or tradesperson MOON, KENT ALAN Principals MOON, KENT ALAN, PRESIDENT SUNDAY, EUGENE R, PRESIDENT (End: 01/10/2011) Doing business as LAKEVIEW CONSTRUCTION INC WA UBI No. 601 447 862 10505 CORPORATE DR, #200 PLEASANT PRAIRIE, WI53158 414-657-4222 Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. LAKEVCI072KC Effective — expiration 05/03/1993— 01/13/2015 Bond TRAVELERS CAS & STY CO OF AMER Bond account no. 400MJ9662 $12,000.00 Received by L&I Effective date 02/17/2006 04/23/2006 Expiration date Until Canceled Insurance National Fire Ins of Hartford $1,000,000.00 Policy no. 5082945285 Received by L&I Effective date 12/31/2013 01/01/2012 Expiration date 01 /01 /2015 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601447862&LIC=LAKEVCI072KC&SAW= 11/03/2014