Loading...
HomeMy WebLinkAboutPermit D14-0306 - ANDRADE RESIDENCE - NEW SINGLE FAMILY RESIDENCEANDRADE RESIDENCE 13616 MILITARY RD S EXPIRED 04/27/16 D14-0306 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 1623049416 13616 MILITARY RD S ANDRADE RESIDENCE COMBOSFR PERMIT Permit Number: D14-0306 Issue Date: 3/12/2015 Permit Expires On: 2/10/2016 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: CAMERER JOHN M & SUSAN M 2301 VASHON AVE NE , RENTON, WA, 98059 IMAD BAHBAH 21620 84 AVE S #200 , KENT, WA, 98032 OWNER AFFIDAVIT ON FILE Lender: Name: A & E HOMES Address: 10925 SE 244 ST , KENT, WA, 98030 Phone: (253) 468-7696 Phone: Expiration Date: DESCRIPTION OF WORK: CONSTRUCT NEW 2448 SQ FT SINGLE FAMILY RESIDENCE WITH 602 SQ FT ATTACHED GARAGE AND108 SQ FT UNCOVERED DECK REVISION #1 TO ADD GAS PIPING, A GAS FIREPLACE AND A SECOND FURNACE (UPSTAIRS) TO SCOPE OF WORK Project Valuation: $340,603.78 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: V-B Electrical Service Provided by: TUKWILA FIRE SERVICE Fees Collected: $10,690.88 Occupancy per IBC: R-3 Water District: 125 Sewer District: NONE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 75 Fill: 75 Number: 0 1 No Permit Center Authorized Signature: Date: B7 - 2Lto ~4S I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit hd agre o the conditions attached to this permit. Signature: Date: Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 2: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 3: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 4: Adequate ground ladder access to rescue windows shall be provided. Landscape a flat, 12' deep by 4' wide area below each required rescue window. (City Ordinance #2435) 5: Maximum grade for all projects is 15% with a cross slope no greater than 5%. (City Ordinance #2435) 1: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 6: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 7: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 8: ***PUBLIC WORKS PERMIT CONDITIONS*** 9: The applicant or contractor must notify the Public Works Inspector at (206) 433-0179 upon commencement and completion of work at least 24 hours in advance. All inspection requests for utility work must also be made 24 hours in advance. 10: Permit is valid between the weekday hours of 7:00 a.m. and 5:00 p.m. only. Coordinate with the Public Works Inspector for any work after 5:00 p.m. and weekends. 11: Any material spilled onto any street shall be cleaned up immediately. 12: Temporary erosion control measures shall be implemented as the first order of business to prevent sedimentation off -site or into existing drainage facilities. 13: The site shall have permanent erosion control measures in place as soon as possible after final grading has been completed and prior to the Final Inspection. 14: The Land Altering Permit Fee is based upon an estimated cubic yards of cut and cubic yards of fill. If the final quantity exceeds this amount, the developer shall be required to recalculate the final quantity and pay the difference in permit fee prior to the Final Inspection. 15: From October 1 through April 30, cover any slopes and stockpiles that are 3H:1V or steeper and have a vertical rise of 10 feet or more and will be unworked for greater than 12 hours. During this time period, cover or mulch other disturbed areas, if they will be unworked more than 2 days. Covered material must be stockpiled on site at the beginning of this period. Inspect and maintain this stabilization weekly and immediately before, during and following storms. 16: From May 1 through September 30, inspect and maintain temporary erosion prevention and sediment at least monthly. All disturbed areas of the site shall be permanently stabilized prior to final construction approval. 17: Downspouts, driveway, patio and drainage from other impervious areas shall be collected in an on -site storm drain system. Drains shall be 4" minimum diameter, PVC schedule 40 or corrugated poly ethylene pipe with a minimum 1% slope for gravity discharge to location approved by the Public Works Department. Downspouts shall not connect to footing drains. Footing drain and downspouts may share a single discharge pipe downstream of the lowest footing drain. 18: Install yard drain(s) and perforated pipe along the driveway, as necessary to prevent on -site ponding of storm water runoff. 19: The house fire sprinkler system shall be designed by a Fire Sprinkler System Designer. Designer shall verify in writing to the Public Works Inspector that a 3/4-inch water meter and service line meets domestic water and fire flow requirements. If domestic water and fire flow requirements are not met, then a 1-inch water meter with a 1-inch service line is required. Refer to attached Public Works Details for 1" FIRE/DOMESTIC SERVICE and/or 1" FLOW -THROUGH SYSTEM. Coordinate with Public Works Project Inspector. 20: Prior to issuance of this permit, Transportation Impact Fee shall be paid in the amount of (based on calculation by Senior Transportation Engineer). 21: ***BUILDING PERMIT CONDITIONS*** 22: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 23: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 24: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 25: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 26: All wood to remain in placed concrete shall be treated wood. 27: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 28: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 29: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 30: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one-third and lower one-third of the water heater's vertical dimension. A minimum distance of 4-inches shall be maintained above the controls with the strapping. 31: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 32: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 33: Preparation before concrete placement: Water shall be removed from place of deposit before concrete is placed unless a tremie is to be used or unless otherwise permitted by the building official. All debris and ice shall be removed from spaces to be occupied by concrete. 34: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 35: ***MECHANICAL PERMIT CONDITIONS*** 36: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 37: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 38: Manufacturers installation instructions shall be available on the job site at the time of inspection. 39: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 40: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 41: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 42: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 43: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 44: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 45: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 46: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 47: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 48: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 49: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 50: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 51: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 52: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 53: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 5180 BACKFLOW - FIRE 1700 BUILDING FINAL** 0301 CONCRETE SLAB 5000 CURB, ACCESS, SDW 0610 ENERGY EFF CERT 5200 EROSION MEASURES 5210 EROSION MEASURES FNL 1400 FIRE FINAL 0201 FOOTING 0202 FOOTING DRAINS 0200 FOUNDATION WALL 0409 FRAMING 0708 GAS FIREPLACE INSERT 2000 GAS PIPING FINAL 0606 GLAZING 8004 GROUNDWORK 8004 GROUNDWORK 5040 LAND ALTERING 5040 LAND ALTERING 0502 LATH & GYPSUM 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 1900 PLUMBING FINAL 0101 PRE -CONSTRUCTION 1600 PUBLIC WORKS FINAL 5160 PUBLIC WORKS PRE -CON 0401 ROOF SHEATHING 0603 ROOF/CEILING INSUL 9002 ROUGH -IN GAS PIPING 0701 ROUGH -IN MECHANICAL 8005 ROUGH -IN PLUMBING 0602 SLAB/FLOOR INSUL 5090 STORM DRAINAGE 5090 STORM DRAINAGE 0412 UNDERFLOOR FRAMING 0601 WALL INSULATION 0413 WALL SHEATHING/SHEAR Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 1623049416 13616 MILITARY RD S ANDRADE RESIDENCE COMBOSFR PERMIT Permit Number: D14-0306 Issue Date: 3/12/2015 Permit Expires On: 9/8/2015 Owner: Name: Address: CAMERER JOHN M & SUSAN M 2301 VASHON AVE NE , RENTON, WA, 98059 Contact Person: Name: IMAD BAHBAH Address: 21620 84 AVE S #200 , KENT, WA, 98032 Contractor: Name: Address: License No: OWNER AFFIDAVIT ON FILE Lender: Name: A & E HOMES Address: 10925 SE 244 ST, KENT, WA, 98030 Phone: (253) 468-7696 Phone: Expiration Date: DESCRIPTION OF WORK: CONSTRUCT NEW 2448 SQ FT SINGLE FAMILY RESIDENCE WITH 602 SQ FT ATTACHED GARAGE AND108 SQ FT UNCOVERED DECK Project Valuation: $340,603.78 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: V-B Electrical Service Provided by: TUKWILA FIRE SERVICE Fees Collected: $10,624.38 Occupancy per IBC: R-3 Water District: 125 Sewer District: NONE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 75 Fill: 75 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: 1 Street Use: Water Main Extension: Water Meter: No -, Permit Center Authorized Signature Date: 0340-5 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development per t and agree to tie conditi.ns attached to this permit. Signature: Print Name: Date: 2►i 3 --(2 ^/5� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 2: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 3: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 4: Adequate ground ladder access to rescue windows shall be provided. Landscape a flat, 12' deep by 4' wide area below each required rescue window. (City Ordinance #2435) 5: Maximum grade for all projects is 15% with a cross slope no greater than 5%. (City Ordinance #2435) 1: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 6: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 7: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 8: ***PUBLIC WORKS PERMIT CONDITIONS*** 9: The applicant or contractor must notify the Public Works Inspector at (206) 433-0179 upon commencement and completion of work at least 24 hours in advance. All inspection requests for utility work must also be made 24 hours in advance. 10: Permit is valid between the weekday hours of 7:00 a.m. and 5:00 p.m. only. Coordinate with the Public Works Inspector for any work after 5:00 p.m. and weekends. 11: Any material spilled onto any street shall be cleaned up immediately. 12: Temporary erosion control measures shall be implemented as the first order of business to prevent sedimentation off -site or into existing drainage facilities. 13: The site shall have permanent erosion control measures in place as soon as possible after final grading has been completed and prior to the Final Inspection. 14: The Land Altering Permit Fee is based upon an estimated cubic yards of cut and cubic yards of fill. If the final quantity exceeds this amount, the developer shall be required to recalculate the final quantity and pay the difference in permit fee prior to the Final Inspection. 15: From October 1 through April 30, cover any slopes and stockpiles that are 3H:1V or steeper and have a vertical rise of 10 feet or more and will be unworked for greater than 12 hours. During this time period, cover or mulch other disturbed areas, if they will be unworked more than 2 days. Covered material must be stockpiled on site at the beginning of this period. Inspect and maintain this stabilization weekly and immediately before, during and following storms. 16: From May 1 through September 30, inspect and maintain temporary erosion prevention and sediment at least monthly. All disturbed areas of the site shall be permanently stabilized prior to final construction approval. 17: Downspouts, driveway, patio and drainage from other impervious areas shall be collected in an on -site storm drain system. Drains shall be 4" minimum diameter, PVC schedule 40 or corrugated poly ethylene pipe with a minimum 1% slope for gravity discharge to location approved by the Public Works Department. Downspouts shall not connect to footing drains. Footing drain and downspouts may share a single discharge pipe downstream of the lowest footing drain. 18: Install yard drain(s) and perforated pipe along the driveway, as necessary to prevent on -site ponding of storm water runoff. 19: The house fire sprinkler system shall be designed by a Fire Sprinkler System Designer. Designer shall verify in writing to the Public Works Inspector that a 3/4-inch water meter and service line meets domestic water and fire flow requirements. If domestic water and fire flow requirements are not met, then a 1-inch water meter with a 1-inch service line is required. Refer to attached Public Works Details for 1" FIRE/DOMESTIC SERVICE and/or 1" FLOW -THROUGH SYSTEM. Coordinate with Public Works Project Inspector. 20: Prior to issuance of this permit, Transportation Impact Fee shall be paid in the amount of (based on calculation by Senior Transportation Engineer). 21: ***BUILDING PERMIT CONDITIONS*** 22: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 23: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 24: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 25: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 26: All wood to remain in placed concrete shall be treated wood. 27: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 28: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 29: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 30: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one-third and lower one-third of the water heater's vertical dimension. A minimum distance of 4-inches shall be maintained above the controls with the strapping. 31: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 32: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 33: Preparation before concrete placement: Water shall be removed from place of deposit before concrete is placed unless a tremie is to be used or unless otherwise permitted by the building official. All debris and ice shall be removed from spaces to be occupied by concrete. 34: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 35: ***MECHANICAL PERMIT CONDITIONS*** 36: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 37: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 38: Manufacturers installation instructions shall be available on the job site at the time of inspection. 39: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 40: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 41: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 42: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 43: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 44: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 45: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 46: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 47: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 48: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 49: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 50: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 51: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 52: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 53: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 5180 BACKFLOW - FIRE 1700 BUILDING FINAL** 0301 CONCRETE SLAB 5000 CURB, ACCESS, SDW 0610 ENERGY EFF CERT 5200 EROSION MEASURES 5210 EROSION MEASURES FNL 1400 FIRE FINAL 0201 FOOTING 0202 FOOTING DRAINS 0200 FOUNDATION WALL 0409 FRAMING 0606 GLAZING 8004 GROUNDWORK 5040 LAND ALTERING 0502 LATH & GYPSUM 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 1900 PLUMBING FINAL 1600 PUBLIC WORKS FINAL 0401. ROOF SHEATHING 0603 ROOF/CEILING INSUL 0701 ROUGH -IN MECHANICAL 8005 ROUGH -IN PLUMBING 0602 SLAB/FLOOR INSUL 5090 STORM DRAINAGE 0412 UNDERFLOOR FRAMING 0601 WALL INSULATION 0413 WALL SHEATHING/SHEAR CITY OF TUI ILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Combination Permit No. 112-1 - 0 &ob Project No.: Date Application Accepted: Date Application Expires: (For office use only) COMBINATION PERMIT APPLICATION - NEW SINGLE FAMILY Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION «� 1 Y� Site Address: � � I/ 1 i Pkar .S PROPERTY OWNER /i, ' Name: /ds/ L—C Address: / eq .25 5 244.-).1 34, City: K-> State:(�t/� f Zip: 71036 CONTACT PERSON — person receiving all project communication sT R p / /f��t .,���� J/� Name: �/t1 A �I4G i //f�6 � 1r �'",i 1 Address: .240 U irk , SF a 240 City: �p„ . -- State: --- Zip: / 3 2 Phone: 3 ,_ ju Cate ���b Fax: Email: I'm ade i 4.6 a reA. fe , c GENERAL CONTRACTOR INFORMATION Company Name: 1€70 Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: King Co Assessor's Tax No.: /hZ3D ARCHITECT OF RECORD �/ Company Name: Hie r 1t=Q, Architect Name: jtoit2A/L 1 4 Address: ip. jb,e, c%'-(' Are " Ste` -z1:OD City: b•e , .. f -- State: 4_-- Zip: &23G Phone: g,5-3...460 ,7j_GI_ Fax. Email: ef @�/71�AL cfrd.,/j_e,7 ,caw) /l: ENGINEER OF RECORD Company Name: AI Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: I-,�Al, r .v.-- Addres . C : State: Zip: tl4 1- t 244 '7e2230 H:\Applications\Forms-Applications On Line\2011 Applications\Combination Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 4 PROJECT INFORMATION - Valuation of project (contractor's bid price): $ Scope of work (please prov'de detaile information): syf Si-- caerk /7.57.w 0 DETAILED BUILDING INFORAMTION - PROJECT FLOOR AREAS PROPOSED SQUARE FOO AGE Basement lst floor / 1 oQ 2nd floor /2-415 Garage carport ■ C(l/2.2. Deck - covered., uncovered VI` o Total square footage '3 / 9 Per City of Tukwila Ordinance No. 2327, all new single family homes are required to have an automatic fire sprinkler system installed in the home. Please contact the Tukwila Fire Department for more information - 206-575-4407. EQUIPMENT AND FIXTURES - INDICATE NUMBER OF EACH TYPE OF FIXTURE TO BE INSTALLED AS PART OF YOUR PROJECT. MECHANICAL: Value of mechanical work $ furnace <100k btu thermostat emergency generator Imo/ 000 PLUMBING: Value of plumbing/gas piping work $ 2. bathtub (or bath/shower combo) dishwasher 5- lavatory (bathroom sink) water heater (gas) appliance vent wood/gas stove fuel type: 4V j electric other mechanical equipment / 3, soy bidet floor drain sink lawn sprinkler system 1 gas ,..1614 ventilation fan connected to single duct water heater (electric) clothes washer shower water closet gas piping ou RECEIVED CITY OF TUKW LA AUG 17 2015 PERMIT ENTER H:\Applications\Porms-Applications 0n Line\2011 Applications\Combination Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 4 TUBLIC WORKS PERMIT INFO),_ ATION - Scope of work (please provide detailed information): Ca11 before you Dig: 811 Please refer to Public Works Bulletin #I for fees and estimate sheet. WATER DISTRICT ❑ .. Tukwila tgr..Water District #125 ❑ .. Letter of water availability provided ❑... Highline ❑ .. Renton SEWER DISTRICT ❑ .. Tukwila ...Valley View ❑... Renton ❑ .. Seattle ❑ .. Sewer use certificate 0 ...Letter of sewer availability provided SEPTIC SYSTEM: Ali t 0 .. On -site septic system — for on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. SUBMITTED WITH APPLICATION (MARK BOXES WHICH APPLY): Civil Plans (Maximum Paper Size — 22" X 34") ❑ .. Technical Information Report (Storm Drainage) ❑... Geotechnical Report ❑ ...Hold Harmless — (SAO) ❑ .. Bond 0...Insurance ❑... Easement(s) ❑... Maintenance Agreement(s) ❑ ...Hold Harmless — (ROW) PROPOSED ACTIVITIES (MARK BOXES THAT APPLY): ❑ .. Right -Of -Way Use - Potential disturbance0...Construction/Excavation/Fil1- Right -of -Way... ❑ -or- Non Right -of -Way.. 0 L Total Cut V .. Total Fill .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control Cubic Yards Cubic Yards ❑... Work In Flood Zone . Storm Drainage 0...Abandon Septic Tank 0...Curb Cut 0...Pavement Cut 0...Looped Fire Line ❑ .. Permanent Water Meter Size WO # ❑ .. Residential Fire Meter Size _ " WO # ❑ .. Deduct Water Meter Size ❑ .. Temporary Water Meter Size " WO # 31 X.. Trench Excavation .. Utility Undergrounding 0 ..Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Sewer Main Extension Public ❑ - or - Private 0 ❑ .. Water Main Extension Public ❑ - or - Private 0 FINANCE INFORMATION — THIS I FORMATION IS REQUIRED TO BE FILLED OUT WHEN REQUESTING WATER OR SEWER SERVICE Fire line size at property line _ #1 number of public fire hydrant(s) / [jai .. water U!. sewer ❑ .. sewage treatment MONTHLY SERVICE BILLING TO: Name: Day Telephone: Mailing Address: City State Zip WATER METER REFUND/BILLING: Name: Day Telephone: Mailing Address: City State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Combination Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES _ )PLICABLE TO ALL PERMITS IN THIS ,'P.LICATION — I, Value of construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed' and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. PROPERTY 0 R OR AUTHOR ' D AGENT - Signature: OV4- Signature: Date: Print Name: 40 134 / Lot k_ Day Telephone: - 76 / (Q Mailing Address: 771 %Nc F 5 1 City State Zip H:\Applications\Porms-Applications On Line\2011 Applications\Combination Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 4 of 4 BULLETIN A2 TYPE C PERMIT FEE ESTIMATE PLAN REVIEW AND APPROVAL FEES DUE WITH APPLICATION PW may adjust estimated fees PROJECT NAME 74 rI dT de- R-- PERMIT # IN14-0 30 �0 (@ l fo /6 1 L ["i/+12Y (L'A, S. If you do not prove a contractor bids or an engineer's estimate with your permit application, Public Works will review the cost estimates for reasonableness and may adjust estimates. 1. APPLICATION BASE FEE $250 (1) 2. Enter total construction cost for each improvement category: Mobilization �� 0. Erosion prevention Water/Sewer/Surface Water 3 S l.�si(�o Road/Parking/Access 0 Old A. Total Improvements ` 6 OV 3. Calculate improvement -based fees: B. 2.5% of first $100,000 of A. C. 2.0% of amount over $100,000, but less than $200,000 of A. D. 1.5% of amount over $200,000 of A. 4. TOTAL PLAN REVIEW FEE (B+C+D) 5. Enter total excavation volume cubic yards 7 cubic yards Enter total fill volume $ 2S'7r52 (4) Use the following table to estimate the grading plan review fee. Use the greater of the excavation and fill volumes. QUANTITY IN CUBIC YARDS RATE Up to 50 CY Free ./ 51 — 100 $23.50 101 — 1,000 $37.00 1,001 — 10,000 $49.25 10,001 — 100,000 $49.25 for 1ST 10,000, PLUS $24.50 for each additional 10,000 or fraction thereof. 100,001 — 200,000 $269.75 for I s' 100,000, PLUS $13.25 for each additional 10,000 or fraction thereof. 200,001 or more $402.25 for 1 s 1 200,000, PLUS $7.25 for each additional 10,000 or fraction thereof. GRADING Plan Review Fees $ 3, 5-0 (5) TOTAL PLAN REVIEW FEE DUE WITH PERMIT APPLICATION (1+4+5) $&% The Plan Review and Approval fees cover TWO reviews: 1) the first review associated with the submission of the application/plan and 2) a follow-up review associated with a correction letter. Each additional review, which is attributable to the Applicant's action or inaction shall be charged 25% of the Total Plan Review Fee. Approved 09.25.02 Last Revised 01/01/14 bi* 0300 RECEIVED CITY OF TUKWILA SEP 18 2014 PERMIT CENTER BULLETIN A2 TYPE C PERMIT FEE ESTIMATE PLAN REVIEW AND APPROVAL FEES DUE WITH APPLICATION PW may adjust estimated fees 6. Permit Issuance/Inspection Fee (B+C+D) $ '247 50 (6) 7. Pavement Mitigation Fee $_ AEt- The pavement mitigation fee compensates the City for the reduced life span due to removal of roadway surfaces. The fee is based on the total square feet of impacted pavement per lane and on the condition of the existing pavement. Use the following table and Bulletin 1B to estimate the p Approx. Remaining Years Pavement Overlay and Repair Rate (per SF of lane width) 20-15 (100%) $10.00 15-10 (75%) $7.50 10-7 (50%) $5.00 7-5 (33%) $3.30 5-2 (25%) $2.50 2-1 (10%) $1.00 0-1 $0.00 8. GRADING Permit Issuance/Inspection Fee Grading Permit Fees are calculated using the following table. Use the greater of the excavation and fill volumes from Item 5. QUANTITY IN CUBIC YARDS RATE 50 or less $23.50 J 51 —100 $37.00 101 — 1,000 $37.00 for lst 100 CY plus $17.50 for each additional 100 or fraction thereof. 1,001 — 10,000 $194.50 for lst 1000 CY plus $14.50 for each additional 1,000 or fraction thereof. 10,001 — 100,000 $325.00 for the 1st 10,000 CY plus $66.00 for each additional 10,000 or fraction thereof 100,001 or more $919.00 for lst 100,000 CY plus $36.50 for each additional 10,000 or fraction thereof. 9. Technology Fee (5% of 6+8) •, . Approved 09.25.02 Last Revised 01/01/14 • 2• $ Ito (7) (9) 1 4 BULLETIN A2 TYPE C PERMIT FEE ESTIMATE PLAN REVIEW AND APPROVAL FEES DUE WITH APPLICATION PW may adjust estimated fees 10. TOTAL OTHER PERMITS A. Water Meter — Deduct ($25) B. Flood Control Zone ($52.50 — includes Technology Fee) C. Water Meter — Permanent* D. Water Meter — Water only* — E. Water Meter — Temporary* * Refer to the Water Meter Fees in Bulletin Al (/a ) Total A through E $ 4-9) 11. ADDITIONAL FEES A. Allentown Water (Ordinance 1777) $ B Allentown Sewer (Ordinance 1777) $ C. Ryan Hill Water (Ordinance 1777) $ — D. Allentown/Foster Pt Water (Ord 2177) $ E. Allentown/Foster Pt Sewer (Ord 2177) $ F. Special Connection (TMC Title 14) $ , G. Duwamish $ �' H. Transportation Mitigation $ /O/� Sg I. Other Fees $ ((( ) Total A through I $ / 3 DUE WHEN PERMIT IS ISSUED (6+7+8+9+10+11) $ //3 ESTIMATED TOTAL PERMIT ISSUANCE AND INSPECTION FEE This fee includes two inspection visits per required inspection. Additional inspections (visits) attributable to the Permittee's action or inaction shall be charged $60.00 per inspection. WATER METER FEE /— Permanent and Water Only Meters Size (inches) Ins ation Cascade Water Alliance RCFC 01.01.2014 -12.3 4 Total Fee 0.75 $625 $6 05 $6630 1 $1125 ,012.50 $16,137.50 1.5 $2425 $3 , $32,450 2 $2825 $48,040 $50,865 $4425 $96,080 $100,505 4 $782 $150,125 $157,950 6 $ 25 $300,250 775 Approved 09.25.02 Last Revised 01/01/14 Temporary Meter 0.75" $300 2.5" $1,500 3 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT I QUANTITY I PAID PermitTRAK $66.50 D14-0306 Address: 13616 MILITARY RD S Apn: 1623049416 $66.50 DEVELOPMENT $66.50 ADDITIONAL PLAN REVIEW TOTAL FEES PAID BY RECEIPT: R6004 R000.345.830.00.00 1.00 $66.50 $66.50 Date Paid: Wednesday, August 26, 2015 Paid By: JOSE GARCIA GONZALES Pay Method: CREDIT CARD 756207 Printed: Wednesday, August 26, 2015 9:01 AM 1 of 1 [SYSTEMS Cash Register Receipt City of Tukwila Receipt Number R4810 DESCRIPTIONS I ACCOUNT I QUANTITY I PAID PermitTRAK $8,121.09 D14-0306 Address: 13616 MILITARY RD S Apn: 1623049416 $8,121.09 DEVELOPMENT $3,471.10 PERMIT FEE R000.322.100.00.00 0.00 $3,466.60 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 IMPACT FEE $2,348.00 FIRE R304.345.852.00.00 0.00 $922.00 PARK R104.345.851.00.00 0.00 $1,426.00 MECHANICAL $189.00 PERMIT FEE COMBOSFR R000.322.100.00.00 0.00 $189.00 PLUMBING $252.00 PERMIT FEE COMBOSFR R000.322.100.00.00 0.00 $252.00 PUBLIC WORKS $1,649.38 PERMIT ISSUANCE/INSPECTION FEE R000.342.400.00.00 0.00 $287.50 CONSTRUCTION PLAN REVIEW R000.345.830.00.00 0.00 $287.50 GRADING PLAN REVIEW R000.345.830.00.00 0.00 $23.50 GRADING PERMIT ISSUANCE R000.342.400.00.00 0.00 $37.00 TRAFFIC IMPACT FEE R104.345.840.00.00 0.00 $1,013.88 TECHNOLOGY FEE $211.61 TECHNOLOGY FEE R000.322.900.04.00 0.00 $211.61 TOTAL FEES PAID BY RECEIPT: R4810 $8,121.09 Date Paid: Thursday, March 12, 2015 Paid By: ANGEL ANDRADE Pay Method: CREDIT CARD 00554D Printed: Thursday, March 12, 2015 12:20 PM 1 of 1 CSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT I QUANTITY I PAID $2,503.29 D14-0306 Address: 13616 MILITARY RD S Apn: 1623049416 $2,503.29 DEVELOPMENT $2,253.29 PLAN CHECK FEE R000.345.830.00.00 0.00 $2,253.29 PUBLIC WORKS $250.00 BASE APPLICATION FEE TOTAL FEES PAID BY RECEIPT: R3086 R000.322.100.00.00 0.00 $250.00 $2,503.29 Date Paid: Thursday, September 18, 2014 Paid By: ANGEL ANDRADE Pay Method: CHECK 2679 Printed: Thursday, September 18, 2014 3:56 AM 1 of 1 C�VVSYSTEMS INSPECTION RECORD Retain a copy with permit CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 ,2c P ojearovi �� Type f Inspe lion: t _1.1 �ceta Address: . t754:016 4441V/cry JDate e. Cal Special- Instructions: 1 �" \ Date nt . a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 94�/ ,,7(arrr,0 Inspector: /\• L.. Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSP INSPECTION RECORD Retain a copy with permit NO. PERMIT NO. 0,6 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Pect: roA-Abode, Ai5 T A- Type of Inspection: C 4 (( r A dr s: I"t (3�0 /6 �tr �r f r A-i r6 Date Called: Special Instructions: AM Date Wanted: 15;'-76-LT a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit Pi ti-da0e PERMIT N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro'ecfc Cr /�' � Typ)t� ps7 tipo4) �j I� Ll1 Address: I31nIk Air(( taffy (Zd s. Date Called: Special Instructions: -� . -S Dat Wanted: a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: inspector: Date: ('oj- REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: A- k?t fr ,& Type f i p V4( ti vi , f0 if\ Address: I3� /1(((fr 1 7 / S5, Date Called: Speci�nstructions: p- / l� Date Wanted: t6 — f `- �.9 a.m. p.m. Requester: Phone No: Approved per applicable codes. EJ Corrections required prior to approval. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Fr INSPECTION RECORD 111 Retain a copywith permit INSP'�.N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Pr 'ect: ` r /' Type of It ection:ee s A r s� 6 1_0, red Date Called: Special Instructions: 4/44 Wanted Datei ^` l�r{ a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. OMMENTS: Inspector: Date? c REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 POI -o'er; Pr jec r r(�0 TYp IA k�� Address "`�l� . 136(6 A(1 / w rd Jae Date Called: Special nstructions: ,/y� 4> Date Wanted: 10." 1' 3 -15— a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: t I— c G(-- (Kg Ptirt- 6 (C. c frail 4 r bttk ( � f` Gz - O 2-) 5 Me-L5/ e-c-J: it) kg i 1 teef 6 i 1 (et le--- ' 0 <Ice,i,1 - Ce._, Aoki er- 4 4A44ces*ioetV4 111'45 $ fr,ce. 2.c-Yss 3 /ice 6e1- A i 1 , C ((i,- re_frt-fgdr o Pt Inspector: ere/ Date:to 3_/� REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ittilt tirade-- l Type of Inspection: Cot-tf e—J(Ctb A/36 (6 A ((( 1, Date Called: Special Instructions: Date Wanted: 0 —Cr a.m. p.m. Requester: Phone No: 4mMENTS: Approved per applicable codes. Corrections required prior to approval. Inspector: r( Date:l (5- REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. SI�'INSPECTION RECORD Retain a copy with permit SPEC NO. D/1-/-g36 b PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-935t t (y,ck3 Project: /� ej Type of Inspect �h: 4ts TT r-49,( ! ;( j . f Date Called: Special Instructions: " �j Date Wanted: �f �— 1 — / ! S a.m. p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. OMMENTS: Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 10 INSPECTION NO. INSPECTION RECORD Retain a copy with permit 1y-030G PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 t: Pro/btJ(L4c/geS i Type of Inspection: ParPart,c k -e CIA Address: 13()6 /14/14Atti Pd Date Called: Special Instructions: q� Iv '' ' Date Wanted: ly-lc-- a.m. p.m. Requester: � Phone No: I 1 ® Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Inspector: 414 Dat .. i( —J REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 1*(4, INSPECTION RECORD Retain a copy with permit INSP ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 1�i�1- 630� Project: /4K)/Y1-ASK /� I2eSrciu&av Type of Inspection: Po/xi\A Flk.v, c Address: / /� �� Date Called: Special Instructions: Q r 'in Date Wanted: 9-13- IS'- a.m. p.m. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: P e 9,9ifs ox- It, 65 Are/ 6 Aenot/ed Inspector: Date: -13-cs REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. /0J INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 D ILI — 030( Project: AvU M-Ps hi I sl c,e_ Type of Inspection: i'V)ec/, leer I((T Address: alai( gibliity Date Called: Special Instructions: Awe Date Wanted: /3-1 S' a.m. p.m. Requester: Phone No: ElApproved per applicable codes. El Corrections required prior to approval. COMMENTS: /1//4 Inspector: �'� i REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Dateg _ . INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 O3C Pro ect: ik itAt 12— �(�� d2eS Typ of Inspection: co r exl 11 Addrgss: 1L3('1(rM r 1 Date Called: Special Instructions: Ai''A 1I�Yt. Date Wanted: '7 ,. 2� 1S a.m. p.m. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspector: —1G( Date rZ1r /5 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. w1I INSPECTION RECORD Retain a copy with permit INSP ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Prot: i�J Type of inspection: LOAt1 Sh wlit- /ir Address: 13L 1(1 M i CtAtty t4:1 so Date Called: Special Instructions: /1141 Date Wanted: -7~ N 1' a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: , Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Z INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pject: rk `-ale ri-Qj Type of Inspection: r-c.�c(er (°att, Address: r3c(6 ticr((ftcfry i JO Date Called: Specia Instructions: it* Date Wanted: 1 (J� a.m. p.m. Reque er: Phone No: Approved per applicable codes. E Corrections required prior to approval. COMMENTS: ecve C> 4-mtC Z Y rc« 1/0 e C Ltd access Inspector: Date—3o REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. r INSPECTION RECORD Retain a copy with permit TION NO. Day-0 0 6 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro'ect: t Type of Inspection &-rottoCuliork Address: t 1" i;) A( Valy fciefOe Date Called: Special Instructions: �M Date Wanted: 6 - z3 - fS" a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Kco(cgoi cc*c_c_kok- Inspector: Date/ REINSPECTION FEE REQUIRED. Prior to next inspection, fete must be paid at 6300 Southcenter Blvd., Suite 100. Catt to schedute reinspection. 1)rY-4030� INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION INSPECTION RECORD Retain a copy with permit 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Pr ject: Type of Ins ektion: r 13 6s 16 A rfr p" ( (6 Date ailed: Special Instructions: ,r�1 4#1 Date Wanted: �f2i`Z—I(( � a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. OMMENTS: Inspector: Datg! _ 22 _ (� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. kcC rel:411INSPECTION RECORD Retain a copy with permit INSPECTIO P -1- 63 0,6 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206)e31-3670 Permit Inspection Request Line (206) 438-9350 F(.4.14sta •ate Project: Type of Lnspec oni t7 lity 'n°0 Address: e 36f6 At( (c1-Qry -b, Date Called: S ecial Instructions: r�„ti Date Wanted: 6 - i 7- (- a.m. p.m. Requester: Phone No: Approved per applicable codes. E Corrections required prior to approval. OM M ENTS: Inspector: Date 0 7` (.5� REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 1)14/-63c)k Prpjeqj dirc42— A-e—S TypeApi of Insction: f Pre---00 c., 'Address: r• ' 1 , t.0 /3A( ( rtrkVr q Jc' Date Called: ' Special Instructions: Date VVn e ED ( a.m. Pim Requester: 'Phone No: Approved per applicable codes. EJCorrections required prior to approval. OM ENTS: Inspector. Date:6 .cr REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedute reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER /S--S-13-) 6 3oh PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 4VP/24 i) e 2--P S Type of Inspection: yew ---' /2.1/ai,--0 Address: Suite #: /36Zv ,/f /ei c Contact Person: 7. Special Instructions: /3(/6 / Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: .6((-7) /4 ' ././n 5 ( //7 .4,-z / / Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: a 2 s - Date: / /2 -2 /— Hrs.: 2 6 / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Address: Company Name: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Prescriptive Energy Code Compliance for All Climate Zones in Washington 'Project Information Contact Information Authorized Representative Andrade Residence 'mad Bahbah / IHB Architects iftpt 253-468-7696 This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed. In addition, based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. �4't_-- Date All Climate Zones R-Valuea U-Factora Fenestration U-Factorb n/a 0.30 Skylight U-Factor n/a 0.50 Glazed Fenestration SHGCb.e n/a n/a Ceiling 49' 0.026 Wood Frame Wall9•'`•' 21 int 0.056 Mass Wall R-Value' 21/21h 0.056 Floor 309 0.029 Below Grade Wall° 10/15/21 int + TB 0.042 Slab° R-Value & Depth 10, 2 ft n/a able R402.1.1 and Table R402.1.3 Footnotes included on Page 2. COpy REVIEWED FOR CODE COMPLIANCE APPROVED NOV 17 2014 City of Tukwila BUILDING DIVISION Each dwelling unit in one and two-family dwellings and townhouses, as defined in Section 101.2 of the International Residential Code shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: 01. Small Dwelling Unit: 0.5 points Dwelling units less than 1500 square feet in conditioned floor area with Tess than 300 square feet of fenestration area. Additions to existing building that are less than 750 square feet of heated floor area. 22. Medium Dwelling Unit: 1.5 points Ali dwelling units that are not included in #1 or #3, including additions over 750 square feet. 03. Large Dwelling Unit: 2.5 points Dwelling units exceeding 5000 square feet of conditioned floor area. 04. Dwelling unit other than one and two-family dwellings and townhouses: Exempt As defined in Section 101.2 of the International Residential Code Table R406.2 Summary Option Description la Efficient Building Envelope la 0.5 • lb Efficient Building Envelope lb 1.0 lc Efficient Building Envelope lc 2.0 2a Air Leakage Control and Efficient Ventilation 2a 0.5 2b Air Leakage Control and Efficient Ventilation 2b 1.0 2c Air Leakage Control and Efficient Ventilation 2c 1.5 3a High Efficiency HVAC 3a 0.5 3b High Efficiency HVAC 3b 1.0 3c High Efficiency HVAC 3c 2.0 3d High Efficiency HVAC 3d 1.0 4 High Efficiency HVAC Distribution System 1.0 5a Efficient Water Heating 0.5 5b Efficient Water Heating 1.5 6 Renewable Electric Energy 0.5 0.5 0.5 ❑ RECEIVED ❑ CITY OF TUKWILA ❑ SEP 18 2014 ❑ PERMIT CENTER ❑� 0.5 *1200 kwh 0.0 Total Credits *Please refer to Table R406.2 for complete option descriptions http://www.energv.wsu.edu/Documents/Table 406 2 Energy Credits 2012 WSEC.pdf 1.50 h1J4 !)2M10 Table R402.1.1 Footnotes ror SI: 1 foot .= 304.8 mm, ci .= continuous insulation, int .= intermediate framing. a Revalues are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration. Exception: Skylights may excluded from glazed fenestration SHGC requirements in Climate Zones 1 through 3 where the SHGC for such skylights does not exceed 0.30. "10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R- 13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1. e There are no SHGC requirements in the Marine Zone. Basement wall insulation is not required in warm -humid locations as defined by Figure R301.1 and Table R301.1. g Reserved. h First value is cavity insulation, second is continuous insulation or insulated siding, so "13.+5" means R-13 cavity insulation plus R-5 continuous insulation or insulated siding. If structural sheathing covers 40 percent or less of the exterior, continuous insulation R-value shall be permitted to be reduced by no more than R-3 in the locations where structural sheathing is used to maintain a consistent total sheathing thickness. The second R-value applies when more than half the insulation is on the interior of the mass wall. For single rafter- or joist -vaulted ceilings, the insulation may be reduced to R-38. k Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. Log and solid timber walls with a minimum average thickness of 3.5 inches are exempt from this insulation requirement. Table R402.1.3 Footnote a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as specified in Section R402.1.3. Simple Heating System Size: Washington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This calculator will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. The glazing (window) and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. Please fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension Program at (360) 956-2042 for assistance. Project Information Anrade Residence Heating System Type: 0 All Other Systems Contact Information O Hea Pump To see detailed instructions for each section, place your cursor on the word "Instructions". Design Temperature Instructions Tukwila Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq.ft) Average Ceiling Height Instructions Average Ceiling Height (ft) Glazing and Doors Instructions Skylights instructions Insulation Attic Instructions 6 R-49 Single Rafter or Joist Vaulted Ceilings Instructions VS -elect R-Value Above Grade Walls (see Figure 1) Instructions Floors Instructions R-21 Intermediate 6 R-38 1-JJ Below Grade Walls (see Figure 1) Instructions Select R-value Slab Below Grade (see Figure 1) instructions Select conditioning Slab on Grade (see Figure 1) Instructions Select R-Value Location of Ducts Instructions • . Unconditioned Space I v ^ J a'svr�4aa wa�C �.. JJJ Figure 1. Above Grade Design Temperature Difference (AT) AT = Indoor (70 degrees) - Outdoor Design Temp 2,400 8.0 U-Factor X 0.30 U-Factor X 0.50 U-Factor X 0.026 U-Factor X No selection U-Factor X 0.056 U-Factor X 0.025 U-Factor X No selection Conditioned Volume 19,200 Area = UA 148.20 Area = UA Area = UA 30.81 Area UA Area UA 202.94 Area UA 32.25 Area UA th UA 494 1185' 3,624 1,290 F-Factor X Len No selection F-Factor X Length UA No selection — Sum of UA Duct Leakage Coefficient 1.10 Envelope Heat Load Sum of UA X AT Air Leakage Heat Load VolumeX 0.6XATX.018 46 414.20 19,053 Btu / Hour 9,539 Btu / Hour Building Design Heat Load 28,592 Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 31,451 Btu / Hour Ducts in unconditioned space: Sum of Budding Heat Loss X 1.10 Ducts in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 44,032 Btu / Hour Building and Duct Heat Loss X 1.40 for Forced Air Furnace Budding and Duct Heat Loss X 1.25 for Heat Pump (07/01/13) Window, Skylight and Door Schedule Project Information Contact Information Andrade Residence, Tukwila, WA !mad Bahbah / IHB Architects 253-468-7696 Exempt Swinging Door (24 sq. ft. max.) Exempt Glazed Fenestration (15 sq. ft. max.) Vertical Fenestration (Windows and doors) Component Description all doors Ref. U-factor Ref. U-factor 0.28 all windows 0.28 Width Height Qt. Feet inch Feet Inch Width Height Qt. Feet Inc' Feet Inch 6 3 6 a 11 4 3 8 Area UA 0.0 0.00 0.0 0.00 Area UA 120.0 33.60 374.0 104.72 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 Overhead Glazing (Skylights) Component Description Sum of Vertical Fenestration Area and UA Vertical Fenestration Area Weighted U = UA/Area Width Height Ref. U-factor Qt. Feet inch Feet Inch Sum of Overhead Glazing Area and UA Overhead Glazing Area Weighted U = UA/Area Total Sum of Fenestration Area and UA (for heating system sizing calculations) 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 494.0 138.32 Area 0.28 UA 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.00 494.0 138.32 { 1 City of Tukwila Department of Community Development 3/1/2016 IMAD BAHBAH 21620 84 AVE S #200 KENT, WA 98032 RE: Permit No. D14-0306 ANDRADE RESIDENCE 13616 MILITARY RD S Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 4/27/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 4/27/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: DI4-0306 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development December 5, 2014 IMAD BAHBAH 21620 84 AVE S #200 KENT, WA 98032 RE: Application No. D14-0306 ANDRADE RESIDENCE 13616 MILITARY RD S Dear IMAD BAHBAH: Jim Haggerton, Mayor Jack Pace, Director Permit application D14-0306 for the work proposed at ANDRADE RESIDENCE (13616 MILITARY RD S) has not been issued by the City of Tukwila Permit Center. Per the International Building, Residential, and Mechanical Codes as well as the Uniform Plumbing Code and/or the National Electric Code, every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire 03/18/2015. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is completed for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that your permit is not issued, we do not receive your written request for extension, or your request is denied your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, e-6W Bill Rambo Permit Technician File No: D14-0306 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development October 30, 2014 IMAD BAHBAH 21620 84 AVE S #200 KENT, WA 98032 RE: Correction Letter # 1 COMBOSFR Permit Application Number D14-0306 ANDRADE RESIDENCE - 13616 MILITARY RD S Dear IMAD BAHBAH, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: _. BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) Structural Drawings and structural calculations sheets by a registered engineer shall have a current signed stamp -seal. Architectural design sheets and documents by a registered architect shall also have a current signed stamp -seal. 5H7. JT -4?pi j 1'1j (BUILDING REVIEW NOTES) 1. On the site plan, provide a plan detail that shows a footing drain or a crawl space water -discharge system. A discharge system shall generally be separate from the roof drain system. The detail shall show size of discharge pit with pit specifications and dimensions or where the discharge pipe shall terminate to an approved culvert with screening. The intent is that groundwater will not accumulate in the crawl space. - tg9aip "4-/. D if 4+7. o Please address the comments_above in an itemize4format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, Bill Rambo Permit Technician File No. D14-0306 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development October 30, 2014 IMAD BAHBAH 21620 84 AVE S #200 KENT, WA 98032 RE: Correction Letter # 1 COMBOSFR Permit Application Number D14-0306 ANDRADE RESIDENCE - 13616 MILITARY RD S Dear IMAD BAHBAH, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) Structural Drawings and structural calculations sheets by a registered engineer shall have a current signed stamp -seal. Architectural design sheets and documents by a registered architect shall also have a current signed stamp -seal. (BUILDING REVIEW NOTES) 1. On the site plan, provide a plan detail that shows a footing drain or a crawl space water -discharge system. A discharge system shall generally be separate from the roof drain system. The detail shall show size of discharge pit with pit specifications and dimensions or where the discharge pipe shall terminate to an approved culvert with screening. The intent is that groundwater will not accumulate in the crawl space. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, Bill Rambo Permit Technician File No. D14-0306 f2n1) Qnnthrantor Rn,, o,,nril Cvito it1M • TL/nA/iln Wnehinrltnn Ok1RR a 7114_d?1_?/71) b v 711K_d21_2K/,S PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0306 DATE: 08/21/15 PROJECT NAME: ANDRADE RESIDENCE SITE ADDRESS: 13616 MILITARY RD S Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued X Revision # 1 after Permit Issued DEPARTMENTS: pro- (?)i Building Division • Public Works n Fire Prevention Structural n Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable _ (no approval/review required) DATE: 08/25/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09/22/15 Approved Corrections Required n Approved with Conditions n Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0306 DATE: 11/07/14 PROJECT NAME: ANDRADE RESIDENCE SITE ADDRESS: 13616 MILITARY RD S Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: PC1 prW CI • 113 'i Building Division Public Works n Fire Prevention Structural n Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 11/11/14 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 12/09/14 Approved Approved with Conditions Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: N61) (e40, St,o REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 TER PLAN REVIEW%ROUTING SLIP PERMIT NUMBER: D14-0306 DATE: 09/18/14 PROTECT NAME: ANDRADE RESIDENCE SITE ADDRESS: 1364t MILITARY RD S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 1\2_ Buildin -Division g k1'v\ plc lo:0i <<` Public Works Fire Prevention Structural n tanning Division1 ti Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 09/23/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 10/21/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only /�� CORRECTION LETTER MAILED: 10 _ 3 0' Departments issued corrections: Bldg' Fire ❑ Ping ❑ PW ❑ Staff Initials: we_ 12/18/2013 PROJECT NAME: AN r 'r` 2 SITE ADDRESS: MOl ve Mt i`I�1► it PERMIT NO: tJF O ORIGINAL ISSUE DATE: 121 I5 REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF t_ gi 9 -4 6.,-(it vt4 4 _,__,_INITIALS/ Summary of Revision: 4 . e AMtii artailv.,e, Ak 4je'-,. Received by: jobyyn REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) Date: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # 6 after Permit is Issued 1)-1---020r� Revision requested by a City Building Inspector or Plans Examiner Project Name: (l/eiti,S icx-�( CQ Project Address: l3 CD 1 (Q N\ t t `i--Gn ✓. f Contact Person: 'v„e-\ 01\,d'y'(c4 I Phone Number: c:91nG 9-7/ - 59 C/ Summary of Revision: CM OF TUKWH 4 ogRMlT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: ( I ---Entered in TRAKiT on City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: /1/7fri-- Plan Check/Permit Number: D 14-0306 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner RECEIVED CRY OF TUK IL :07 2014 PERMIT CENTUR Project Name: Andrade Residence Project Address: 13616 Military Rd S r� ! -7 Contact Person: /m I. 16 �/ 6 k Phone Number: /� / -6 0 l 6 Summary of Revision: .Sir 4,0 er 7L1 ti Lk_ oC -tx. rat Sheet Number(s): f L / 747 t) "Cloud" or highlight all areas of revision including dptepf revision e„...2c.„( Received at the City of Tukwila Permit Center by: ---Entered in TRAKiT on il'11' \applications\forms-applications on line\revision submittal Created: 8-13-2004 Revised: 3460 S 148rh suite 100 J _IE't t: Seattle, WA 98168 Phone: (206) 242-3236 Fax: (206) 242-1527 CERTIFICATE OF SEWER AVAILABILITY / NON AVAILABILITY C 1 1 Residential: $ 50.00 Cortunercial: $ 100.00 (Certificate of Sewer Availability OR C Certificate of Sewer Non -Availability Part A: (To Be Completed By Applicant) . Purpose of Certificate: , ... : . 07i Building Pemmit ❑ Preliminary Plat or PUR ❑ Short Division ❑ Rezone ❑ Other Proposed Use: ❑ Commercial Residential Single Family ❑ Residential Multi -Family D Other Applicant's Name EE ..,Z.YjyIV /tea /11-a A Phone Number igi53-'4Q3-7440 Property Address LI �( (-C1 /.. S. Tax Lot Number�4 4.4. 9 4 Legal Description (Attach Map and legal Description if Necessary ); anl2 Part B: (To be Completed fly Sewer Agency' 1 OR ❑ a. A Sewer Service will be provided by side sewer connection only to an existing `7 size sewer , 6N #re the the has -f site and sewer system the capacity to serve the proposed use, .. b. Sewer service will require an improvement to the sewer system of: ❑ CO ! feet of sewer trunk or lateral to reach the site; and/or (2) The construction of a collection system on the site and/or ❑ (3) Other (describe) I 2. Must be completed if 1. b above is checked C a. The sewer system improvement is in conformance with a County approved sewer comprehensive RE plan, CITY OF oft ( b. The sewer system improvement will require a sewer comprehensive amendment. 3. C a. The proposed project is within the corporate limits of the Dish'ict, or has been granted Boundary SE P Review Board approval for extension of service outside the District. OR C a. Annexation 01 BRB approval will be necessary to provide service. PERMIT 4, Service a. h. c. I hereby from the is subject to the following; Permit $ IOC) . C District Connection Charges due prior to connection: GFC: Si. I SEC: $ Unit $ `` Total $ (Subject to Change on January 1st) Either a in County/METRO Capacity Charg4WSSD or Midway S wer District Connection Charge may be clue upon connection to sewers. H_ Easements: 0 Ea emer ts. El Required 0 be equrred Other I certify that the above sewer agency information is true. This certification shall be valid for one year date of signature. ((qq {{11 t By ride €I EGS ��Pjr✓ �C•� �,etr Date %/I V020Iq EIVED TUKWILA 82014 ENTER Dep ent of c.,e; 6300 Southcenter Boulevard, Suite #100 Tukwila. Washington 98188 Phone: 206-431-3670 Web site: hnpi/www.TukwiiaWAgov Part A: To be completed by applicant Site address (att ch and legal descf iplion showing hydrant location and size of main): ; 71 S 67e/C, Owner information • Name: 14-#47 yo,,,,,es, :Name: Ateh) S4MatiA Address: /007.25 „/.4f77-1 Address: pjcp,g0 - _ 7 7Ve S 2.02 Phone: leo" _ 2,7 1.. 5c14/ '444 Phone: 0,5, ..... 46e This certificate is for the purposes of Residential Building Permit C.!ommercialandustrial Building Permit Agent/Contact Person 67g1,93e) O Preliminary Plat O Rezone 1$ Estimated number of service connections and water meter size(s): Vehicular distance from nearest hydrant to the closest point of -tructure is Area is served by (Water Utility District): Short Subdivision L Other .Date Part B: To be completed by water utility district I. The proposed project is within 2. No improvements required. 3. The improvements required to upgrade the water system to bring it into compliance with the utilities' compreh,:hsi.,,,i minimum flow requirements of the project before connection and to meet the State cross connection contro: SLviE L,.E A A)L A7 &Jgc T- r/ii er p 2 3/4'. ice d- .0K Ere--.4. /Use separate sheet if more room is heeded) 4. Based upon thc improvements listed above, water can be provided and will be available at the site with a flew of '2; 20 residual for a duration of 2 hours at a velocity of i 0 fps as documented by the attached calculations. 5. Water av ilability: rm- Acceptable service can be provided to this project -1 System is not capable of providing service to this project. I hereby certify that the above information is true and correct. Krt Agency/hone .55-17 5 Acceptable service cannot he provided to this project unless the improvements in Item B-2 are met. By 1-41,030 RECEIVED CITY OF TUKWILA SEP 1# 2014 pRMIT CENTER onft 7-1 5") 1. '. T"'r' ..a.✓...% 3;able or r a: ...fsr shall j ave ghvernmehtal r;, v_ li d tea, pro, the r equi''st of pia ie ty thor Warty. F:orther, no third ai u idL. r whether let er by agency or ovals r.`tnd isdiCtOri cant can utilize the i..._s .:e CErtifioate, ai.iictwater available to oiiiity service to , iB real property w ch is the ibjeott c f t; ... ez uficate, and the Y i - t .• may be � e exist :� applicant top service to such property. However, the issuance of this Certificate creates no contractual relationship between the District and the applicant or the City, and the issuance of this Certificate may not be relied upon and does•not constitute the District's guarantee that water utility service will be available to the real property at the time the applicant may apply to t# e District for such ser, ice. 4. Application for and the possible provision of District utility service to the real property which is the subject of this Certificate shall be subject to and conditioned upon the availability of water service to the real iy at the time of such application, as well as all application for utility service, including conservation, water restrictions, and other olic es and i'egulat on then i, i effect. 9- CITY OF TUKWILA Department of Community Development 630o Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-367o FAX (206) 431-3665 Permit Center/Building Division 206 431-367o Public Works Department 206 433-0179 Planning Division 206 431-367o AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON) ) ss. COUNTY OF KING ) , states as follows: [please print name] PERMIT NO: £I / 3° k 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number 1 g--, and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state lqw in any decision to engage an unregistered contractor to perform construgon work. LAURIE A. WERLE NOTARY PUBLIC STATE OF WASHINGTON G COMMISSION EXPIRES MAY 29, 2018 Owner/Owner's Agen Signed and sworn to before me this day of ina , 20 /$ . ,Q" PUBLIC in and for the State of Washington Residing at King Name as commissioned: , County Laurie A Werle My commission expires: 05/29/18 18.27.090 Exemptions. The registration provisions of this chapter do not apply to: 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile/manufactured home retail dealer or manufacturer licensed under chapter 46.7o RCW who shall warranty service and repairs under chapter 46.7o RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; io. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; ii. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile/manufactured home dealer or manufacturer who subcontracts the installation, set-up, or repair work to actively registered contractors. This exemption only applies to the installation, set-up, or repair of the mobile/manufactured homes that were manufactured or sold by the mobile/manufactured home dealer or manufacturer; 18. An entity who holds a valid electrical contractor's license under chapter 19.28 RCW that employs a certified journeyman electrician, a certified residential specialty electrician, or an electrical trainee meeting the requirements of chapter 19.28 RCW to perform plumbing work that is incidentally, directly, and immediately appropriate to the like -in -kind replacement of a household appliance or other small household utilization equipment that requires limited electric power and limited waste and/or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. * Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions. REVISIONS !o Ch"a pas shall be made to the scope of ° :y:c without prior approval of ' h.i tbvi!a Buitcling Division. T'" G >•fii! r4:.:Iuir a n-^, r p!s.n submittal p!2n rsyicsw f;.t UPPER FLOOR LINE HDU4 N ELEC. PANEL FILE CO »y Permit No. Fran review approval is subject to errors an:_t C,'.iiSjOns, A .=,p"Oval r'f Construction documents does (nL.: . °"z,_;r ize violation of any adopted code or ordinenc . cf a boats ad Field Co an, conditions is aduic,,,12d- ' City of Tukwila BUILDING DIVISION 40"0" 23'-0" (FOR GARAGE PORTAL FRAMING SEE DETAIL 11/ A7,01 HDU4 or STHD14 HDU4`or STHD14' Ili 5.r(i T1l''1 "rINB-Yf/ 11c1 eaclif41(IBEtxt-car I443 1 6,161• n 0:120" ran z 1-1/r (trig min 318 t1t / \\ 1 u c. edrpe :,pacnifj a8 a.e. laid spa bindiad ,,,STEP ON li :STEP DN -N Laundry CHUTE ABOVE Storage,' STEP DN: a1EPD''( HDU8 FURII Dv t0•-a ---�1 23'-0• Kitchen tl W. DBL. SINK j�f�-• - Patio i I ad) HU�12 • DECK ABOVE To S I EP:ON g. Foyer UPPER FLOOR LINE 6'-41/2" HOW- I 18'.SO. BOXED co{.. W/STONE VENEER PER DETAIL, I t /A7.0 - HT. .PER :ELEVATIONS Bedroom 2 PEI) SINK RAILING - Great Room r0J E SHELF 4,_7Y' 1 T-0' 40'-0' .Lo uiRED r .4 chanic: tactrics! ,glilumbin. as Pipi: of Tu', :i.r'!NG Di 1 24' G0'.C1 AWL ACCESS PANEL Main Floor Plan SCALE: 1J4"= 1'-0„ HiGH WALL. ZERO CLEARANCE F.P. W/ OUTSIDE AIR SUPPLY: PROVIDE E4' TYPE X GWB FOR I44OUR RATED ASSEMBLY UNDER STAIR. no VE n•I b 2v • DOOR SCHEDULE Q Mark Exposure Qtv NominalSiz. Door type Frame Remarks Width Height Thick. Mat i Fin. Mat- Fin- 1t in ft in in 100 EXT 1 3 0 6 8 13/4 sc. : sTN Uf0 sTN Entry door w/elite 101 EXT 1 3 a 6 8 13/4 SC PNT WD PNT W/Sett closing hardwr 102 EJfT 1 2 8 6 8 13/4 WO PNT WD PNT :Garage man door 103 EXT 3 6 a 6 8: - , VIN FACT VIN FACT Patio sliding door 104 EXT . d 16 0 7 0 - - - . _ Garage rall-up door 105 INT 8 2 6 . 6 8 13/8 ' WO PNT WD PNT 106 : INT i 1 2 8 6 8 13/8 WO - PNT.. WD r PNT 107 INT 2 (2)-2 4 6 a 13/8 WO PNT WO PNT French door w/ lite 108 INT 2. (2r2 6 6 8 13/8 WO PNT ' WD PNT Franch door 109 INT 2 (21-2 6 6 8' a 3/8 WO PNT WO PNT BY' Pass doors 110 INT' 1' (2)4 6 6 8 - WD PNT WO PNT Bl-fofddoors :(Pantry) GARAGE WALL - - BELOW LINE OF ROOF BELOW A4,0• r-t LJ 40'-0' WINDOW SCHEDULE 0 Nark: Qty Nominal Six Type Frame: Rating Ramada Width Height: Fin. U-Fact. Solar it In • .fb. .. A 1 1 3 5 0 FXD Entry skis lice 8 1 4 9 1 6 FXD a : t z 5 6- Transom above door- C 1 2 0 2 6 FXD Transom 0 2 2 a 5 0 FXD E 2. 26 40 SH F 9 3 0 4 0 SH G 5 3a 50 SH:: H 1... 4 a 3 6 SLDR Above double sink 1 1 4 a 4 0 FXD Above stair landing K 5 3 a 4 0 FXD At Great Rm popout L S• 3 a 2 6 FXD At Great Rmpayout M 2 4 a 3 U FXD Master Suite Ratite 2'-53-2' SHF 11.4' 5',63/4' M$Tj;4O, wrap to I ,notch tr a rif boa 'T Bedroom 3 -(rotd iftLF -- e 0. So" VANITY Bath CAB. W/ LAUNDRY CHUTE 3' EO 3•-5• 1 I'•5' Bedroom 4 T-81/2'. 109 1, RAILING -� 5',6• 11'4' ( Loft 10'-9' r-MSTCaa N _� Th5ru.•;-r= 22'40-ATTIC ACCESS PANEL 60'.a3TUUB ru SHWR ° 11RI3 R SHELF I _ I a: i ----- 9 SHF 1 5 I W.I.C. 5'-g 4 -if; 11 II 11 IP -tt 11= III 11 Ili Wl MSTC4O--- • Master Bath I I r1 /h.t1 .._,_:_ ,,per,_.- ,ILT.Srta WAW..." 3'-81/4• 11%0' 3 A4.0 0 _-_ >Ii H. A S. 6.-11' Master Suite Floor Plan General Notes. w4 HIGH WALL .---MSTC28 Open to Below 4 410 .1 faft16,5,74•111a is 13I idt/rsidfauftearTrlt agt°a is 1' ip_ I3'%6- 6•'73�4:. 4''13/4• L L. 3:-4Y2 3'-4.. 15..6` -. 40'-0' Upper Floor Plan SCALE: 1/4"-1'-0'° 1, All wtsioa and knNe dman(ons ara to to fare e'. mods -(Wass noted odrenviso on: plane) 2. wr0tan,lmoo&ens Lake pmredeece over seaMdtsrrenifats. 3 For. Korn times typesand tocadons sae (Moric4aid mechanical Oars, A, As loot GNslas are owasod toloradcannn. 5. Ad wets IO exterior, 9. Ad settler doors shad ha:opauNe ham italdo risnut rap of keys. 7: Soo refl rate) ceding plans tar stroke danctcrawlairman fan to atlms: 8. Gaieae calIfga to here one hyer of$4. type xGVte. 9, Preiide mra.:ha,drai at stairsa min of 1-1l2 away from wag. 10. Handrail ands Elias W aitur4GS rrshai tamlinxe lei novae peels or slily lerrrdna% 11. FIRE STOPS; Fins Hooking B required in ad Stud wale at cab's d loot Wares: The vortical i ts/arca tampon Elaetdnp alai not armed 10 it 12. AS tureand Stowe=; • ,smk stnwer Aow In 2.5 O.pp.n. • waterproof was loves... 70'. stare train blot • vapor barrier edged Gale: Walt Schedule wl 4 AP 27,206 Porn mw000 WALL:. 0W40.12sr WO STUDS 0I!' OA. StH^,LE TOP a 00T. PL: ... WITIE4' OWN EA 510E 1i(- ON GARAGE SCE) EKTEIe;R WOOd WAtt: (101.0.) 214 WOSTU05 gib r0A.. OVA OR omen 4.21 INSULATION WHERE SHOWN %osa SHEATHING MOISTURE BARMEN (TriE1q EXTERK'R Fc6Sli(SEE ELEV.) Li GA AGE W60 IPoc. sre'�a�sa' VAPOR HARRER OI. R•15 atSU.ATKr4 WHERE. S11C Mrs W OW SHEATHING MOIS11a1E BARRIER ITYVEIQ; EXTERKM Masts (SEE.ELEV.). w4 NIGH WATI 2 S..19194 11105 @ /e'O.C. WIRtp, STOPSAT VERT. 1e-O.0 MAX. Foe OTHER 162160 SEE:.gi EGRESS NOTE: ALL BEDROOM WINDOWS SHALL HAVE AN OPERABLE PANEL AT • LEAST 5.7s.f., SILL HEIGHTS SET AT 44' MAX. A.F.F. TYPICAL EXTERIOR WALL SI-MG: 7/16" OSB W/ 8d. @ 6`" o:c. EDGES &` 12" o.i . FIELD RECEIVED CITY OF TUKWILA AUG 2 1'2015 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED fj�►A�UG 2 5 2015 /i " City of Tukwila BUILDING DIVISION ARCHITECTS 21620 841h Ave. S. Ste: 200 Kent, WA 98032 (253) 468=7696 www.lhearchltects.com The droving.* nun pins sot firth an this says.. Imre:m at ofservicetut. turd shall:mtmia. the pm(xrty:.nf It111 Ahfiileet,.. Usc of this Unwind b limiI01 to a .alreiried pliljcel for poems named:hac,m: And Tor cnnswnion: or one building. Any usc.or -rcusc 1dsaid drawings i .trktly -prohibitedwithout_ wriecn. pcnnissirrn of 018 Arehirerts W' A2.0 Floor Plans rcv Kara, job farO 14-108 dude - November 7, 2014 urnwt. hy: : David Goretoy Tcvicwcdbvr Imed Bahbah' OME PLAN I �- • I i I • A l i 1 A. ._..__A._ 1 .�. 1 L 1..1__1. A...T_ �.... u 0 I A..�...a...,....1A_ i .ri. 1 i • 1 I -1 I i I l A - I i i 1 1 I i 1 i SEPARATE PERMIT REQUIRED FOR: JEechanical tectrtcat 0 Plumbing ❑ Gas Piping City of Tukwila BUILDING DIVISION I 1 II 1 ETA 1. _1 1 -.1--1 _ .!..._I__�. 1._.� 11__ 1 1 r IT "IIj 1 ..�.., .1. .11..1_..A... ...I... ...A,..-...� .1.. ...A_... A... _ A...,-- .. _ �...._.a..-:..� h._.r...i_.._1... `_.A..T.�...._l. _. i..._:`� i ` A_.,...A _...1: I�_A_ _..�_...I'a�.1... r 1 1 1 A_A 1 i _ 1� 1 1. 1 1 I 1 1 j .l - 1 1 I I . 1 1 1 11 1111 f I 1 1 I -r- Permit Set September 16, 2014 REVISIONS No changes shall be mr•,de to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. APR 27 216 PLANNING APPROVED • No changes can be madme plans without approval from the Planning Division of DCD Approved By: l J Date: 1.1_ 1 FILE COPY Permit No. DIL-Hmv(to Plan review approval is subject to errors and omissions. Approval of construction documents does not aui o;ize the violation of any adopted code or ordinance. Recoipt of approved Field Copy and conditions is cknowIedged: By: Date: 3b f f S� City of Tukwila BUILDING DIVISION These plans have been reviewed by the Public Works Department for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards or ordinances. The responsibility for the adequacy of the design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field inspection by the Public Works utilities inspector. Date: By: 10 f'1 /I� athl GENERAL A0.0 COVER SHEET / GENERAL NOTES A1.0 SITE PLAN A1.1 STORM DRAINAGE PLAN RESIDENTIAL A2.0 MAIN & UPPER FLOOR PLAN A3.0 EXTERIOR ELEVATIONS A3.1 EXTERIOR ELEVATIONS A4.0 BUILDING SECTIONS A5.0 WALL SECTIONS A5.1 WALL & STAIR SECTIONS A6.0 ROOF PLAN A7.0 DETAILS A7.1 DETAILS A8.0 REFLECTED CEILING PLAN S1.0 FOUNDATION & MAIN FLOOR FRAMING PLAN S1.1 UPPER FLOOR & ROOF FRAMING PLAN PROJECT DESCRIPTION 2-Story family dwelling with 4 bedrooms and 2 Y2 baths. An open Loft area upstairs with railing throughout, overlooking Foyer and Great Room with high ceilings. Pre -manufactured roof trusses. Residence is VB construction, fully sprinklered. Separate fire sprinkler permit to be submitted by sprinkler contractor. AREAS ROOM S.F. OTHER AREAS S.F. Main 1,200 Covered Entry Stoop 86 Upper 1,248 Deck 108 Total heated 2,448 Rear Conc. Patio 206 Garage & Shop 602 Total 3,050 RESIDENCE & PROJECT ADDRESS 13(pIP Military Rd S. Tukwila, WA 98168 PARCEL: TOTAL ACRES: - PROPERTY SETBACK NEW RESIDENCE CONFORMS TO ALL EXISTING SETBACK REQUIREMENTS PER APPROVED SHORT PLAT 20090626900006 Construction of home must comply with the following energy credit requirements: EFFICIENT BUILDING ENVELOPE la: Increase Fenestration U-factor to : U .= 0.28 Floor insulation shall be R-38 Conc slab shall have R-10 at perimeter and under entire slab AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2a: Reduce the tested air leakage to 4.0 air changes per hour maximum and whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code shall be met with a high efficiency fan (maximum 0.35 watts/cfm), not interlocked with the fumace fan ventilation systems. EFFICIENT WATER HEATING 5a: Electric water heater shall have a minimum EF of 0.93. and all showerhead and kitchen sink faucets installed in the house shall be rated at 1.75 GPM or less. All other lavatory faucets shall be rated at 1.0 GPM or less. 1. All work shall be in accordance with 2012 IRC and 2012 WSEC 2. All electrical work is under separate permit and shall be in accordance with 2012 IEC and state requirements. 3. All dimensions are to face of stud, UNO. 4. All exterior walls are 2x6 @ 16" oc w/ R-21 batt. 5. All interior walls are 2x4 @ 16" oc., unless noted otherwise 6. All lumber in contact with concrete shall be treated or grade shall be treated. 7. Fire Sprinkled throughout per NFPA 13D, under separate permit. ENERGY CODE NOTES This residential unit shall comply with the 51-11 R WAC, 2012 WSEC with State Amendments. The following items shall apply to this project. For entire list of energy code inspection requirements, see 2012 WSEC SINGLE FAMILY COMPLIANCE CHECKLIST. ENVELOPE COMPLIANCE PATH All relevant envelope and fenestration elements of project shall comply w/ table below per 2012 WSEC. SINGLE FAMILY AIM DUPLEXES GLAZING MAX: % OF FLOOR U-FACTOR-- VERTICAL U.FACTOR-Overhead {Skylights) DOOR U-VALUE CEILINGS: WITH ATTICS VAULTED's e below WALLS: ABOVE GRADE BELOW GRADE INTERIOR Or RIGID EXTERIOR. FLOOR: SLAB ON GRADE: tingmited .30 50 20 R-35 R-21 rNT" R-21 TB.. R-15 R-10 R-30 R-10 Intel -ma date Framing - R-10 •nsulated headers `• rt-5 Thermal Break f2equfred R-values are far wood frame assemUaes only EXHAUST FANS Intermittent /Continuous Kitchen fan 100 CFM / 25 CFM Bathroom fan 65 CFM / 20 CFM Laundry fan 65 CFM / 20 CFM REVIEWED FOR CODE COMPLIANCE APPROVED NOV 17 2014 eivi City of I u ifa BUILDING • I ISION WHOLE HOUSE FAN Whole house fan - Continuous Operation ONLY 70 CFM (2-4 bedrooms, <3000 SF) Whole house fan must be minimum Sone rating of 1.0 or lower. and must be labeled "Whole House Ventilation" and must be listed and labeled for continuous use". MECHANICAL Provide blower door and duct testing certificate from testing agency showing test results. Building leakage maximum = .00030. Duct leakage per calculated value on checklist. Provide programmable T-stat w/ 5-2 schedule. AIR BARRIERS Provide caulk/sealant at all joints, transitions In materials and penetrations of envelope. Window and door air leakage measures shall be met as follows: Exterior joints sealed, caulked, gasketed orweatherstripped. Standard air leakage is complete and installed In the following: 1) between sole plate/subfloors 2) wiring/plumbing/duct register penetrations 3) rim joists/mud sills (heated lower floors) 4) partition stud penetrations 5) around window/door frames LIGHTING 75% or more of all light fixtures must be high efficacy (lumen/watt ratio) - flourescent, screw in ok. Indoor lighting shall be 50% compact flourescent (pin or screw) or T-8 latnps or smaller. All flourescent tubes must be T-8 or smaller. Outdoor fixtures attached to building must be pin -based flourescent OR provide motion sensor and photo -cell daylight control. INSULATED HEADERS / BEAMS Provide rigid R-10 insulation in exterior headers where cavity occurs. Jee detail 12/1 A-6.1 RECEIVED CITY OF TUKWILA SEP 18 2014 PERMIT CENTER S 135th St. Tukwila i138th St. S 133rd St. SITE S-:140th St. 1 S 130th St. CP o- 75 EGISTERED iT�. .. :?;': STATE OF WASHINGTON ARCHITECT 21620 84th Ave. S. Ste. 200 Kent, WA 98032 (253) 468-7696 www.ihbarchitects.com The drawings and plans set forth on this set as instrument of service are, and shall remain, the property of Il-IB Architects. Use of this drawing is limited to a specified project for persons named hereon. And for a construction of one building. Any use or reuse of said drawings is strictly prohibited without written permission of 11IB Architects W U Z W CI (in ail OIJ CSa T- co -cy, aN rt ea < W 2 t0 fl ANDRAI A0.0 Cover Sheet revisions: FaI rr: I®��fE0 SEP. 22 2014 PUBLIC WOhf job No: 14-108 date: September 16, 2014 drawn by: David Goretoy A0•0 O 0 116.48' MIND IMMO 001011 109.95' MONO 01111.0 LOT 1 (E) BLDG OMNI- MEND (E) BLDG LINE OF CONC. PATIO AT GRADE 1 N 88°23'00" E 80.19' 1% LOT 2 . _ss LINE OF DECK ABOVE 80.19' S 88°23'00" W APPROVED OCT 07 1014 city r S Tukwila PUBLIC Works — — -I SS-- 28'-0" t w wIZ (n Y W mw N W om of w to Site Plan PIPE & DRAIN ROCK PER DETAIL 4/ A7.0 4" DIA. SOLID PVC OR ADS PIPE TO DRYWELL SCALE: 1" = 10'-0" FIN. GRADE 4" DIA. PERF. PIPE W/ FILTER FIBER WASHED ROCK (E) SCHOOL SITE 1w co cn i) O O B.O. DRYWELL J. SET BOT. OF TRENCH SO FT'G DRAIN HAS MIN. 1% DRAINAGE Dry Well Detail N.T.S. i Site Plan Notes 1. See sheet A1.1 for Storm Drainage Site Plan Legend r wfw � ri A 2% x PROPERTY CORNER PROPERTY LINE — INGRESS & EGRESS EASEMENT BUILDING SETBACKS PER APPROVED SHORT PLAT 20090626900006 SANITARY SEWER EASEMENT NEW BUILDING EXISTING BUILDING ASPHALT CONCRETE SLAB CRUSHED ROCK FENCE GRADE SLOPE DIRECTIONAL ARROW Site Plan Keyed Notes 0060000 10 11 12 13 14 15 16 17 18 REMOVE EXISTING TREE PAVED ASPHALT DRIVEWAY CONCRETE APRON EXISTING PAVED DRIVEWAY LAWN CONCRETE TO EXITING SIDE SEWER STUB HERE EXISTING UTILITY STUBS FROM STREET (WATER, GAS, POWER, TEL./CABLE). EXTEND TO HOUSE FROM THIS LOCATION CONCRETE STOOP 6' HIGH WOOD GATE 6' HIGH WOOD FENCE LANDSCAPING EXISTING 6' CHAIN LINK FENCE EXISTING WATER METER FOR LOT 2 EXISTING GRAVEL AREA EXISTING LANDSCAPE EXISTING FIRE HYDRANT 4" DIA. SOLID PIPE FROM FTG DRAINS 2' W. x 20' L. DRYWELL - SEE DETAIL 1/ A1.0 Impervious Area Calculations HOUSE & GARAGE FOOTPRINT 1,802 s.f. COVERED PORCH 86 s.f. CONCRETE PATIO 206 s.f. CONCRETE DRIVEWAY (APRON) 180 s.f. TOTAL IMPERVIOUS AREA: 3,522 s.f. REVIEWED FOR CODE COMPLIANCE APPROVED NOV 17 2014 City of Tukwila BUILDING DIVISION CORRECTION LTR# 1 APR 27 2018 RECEIVED CITY OF TUKWILA NOV 0 7 2014 PERMIT CENTER REGISTERED ITEM. STATE 01: WASHINGTON ARCHITECTS 21620 84th Ave. S. Ste. 200 Kent, WA 98032 (253) 468-7696 www.ihbarchitects.com The drawings and plans set forth on this set as instrument of service are, and shall remain, the property of 1HB Architects. Use of this drawing is limited to a specified project for persons named hereon. And for a construction of one building. Any use or reuse of said drawings is strictly prohibited without written permission of IHB Architects W 0 z W 0 v ♦ CU W� 00 � OCN Q � (Ci W flM 0 z revisions: City Review Comments 14-108 date: September 16, 2014 drawn by: David Goretoy reviewed by: 'mad Bahbah 0 0 --A `1. :fleet,: 4.* washed r Basic Dispersion Trench Section N.T.S. 1 A1.1 NTS Splash Block Detail N.T.S. N 88°23'00" E 80.19' I (E) (LAWN) / SCHOOL / SITE MINIM (E) BLDG Storm Drainage Plan SCALE: 1" = 10'-0" Dispersion Trench At Driveway N.T.S. A1.1 Site Plan Legend PROPERTY CORNER PROPERTY LINE — — — — INGRESS & EGRESS EASEMENT — BUILDING SETBACKS PER APPROVED SHORT PLAT 20090626900006 —x x 2% SANITARY SEWER EASEMENT NEW BUILDING LINE DISPERSION TRENCH ASPHALT CONCRETE SLAB CRUSHED ROCK FENCE GRADE SLOPE DIRECTIONAL ARROW DOWNSPOUT LOCATION SMALL YARD DRAIN 4" PVC TITE LINE BELOW GRADE VEGETATED FLOW PATH Site Plan Keyed Notes 0 0 0 0 0 0 BASIC DISPERSION TRENCH FOR DRIVEWAY, SEE DETAIL 1/ A1.1 BASIC DISPERSION TRENCH W/ YARD DRAIN FOR DOWNSPOUTS, SEE DETAIL 1/A1.1 COMBINE THE 3 DOWNSPOUTS NORTH SIDE OF HOUSE AND TITE-LINE TO DISPERSION TRENCH AS SHOWN. SPLASH BLOCK AND LEADER AT GRADE TO DOWNSPOUT, SEE DETAIL 2/ A1.1 ROOF AREA, TYPICAL DISPERSION TRENCH AT DRIVEWAY PER DETAIL 3/ A1.1 APPROVED OCT 07 2014 City of Tukwila PUBLIC Works REVIEWED FOR CODE COMPLIANCE APPROVED NOV 17 2014 City of Tukwila BUILDING DIVISION APR 27.201a RECEIVED CITY OF TUKWILA SEP 18 2014 PERMIT CENTER STATE Of WASHINGTON 21620 84th Ave. S. Ste. 200 Kent, WA 98032 (253) 468-7696 www.ihbarchitects.com The drawings and plans set forth on this set as instrument of service are, and shall remain, the property of IHB Architects. Use of this drawing is limited to a specified project for persons named hereon. And for a construction of one building. Any use or reuse of said drawings is strictly prohibited without written permission of IHB Architects a) 0) cc; "i33. o c E 0 et- dC revisions: job No: 14-108 date: September 16, 2014 drawn by: David Goretoy A1.1 rn cr UPPER FLOOR LINE 23'-0" (FOR GARAGE PORTAL FRAMING SEE DETAIL 11/A7.0) ELEC. ELEC. MTR PANEL FIFr'1-TAPED OIL; BOLLARD STEP DN STEP DN fIA9../QJ.0....d.L!i!.!.WAWi4li!il1lDT.lilili!i! J W. D. Laundry CHUTE ABOVE Storage STEP ON STEP DN.----- PE'X' GW: EIL., .............................. 40'-0" SHELVING Pantry Kitchen D.W. DBL. SINK r i!.!0...i s?i...451.1../.0..0.1. / W.!.!i!i!itli!i!i!.t.t..!i!i!i!i!i!vita 23'-0" DECK ABOVE 40'-0" STEP DN.. UPPER FLOOR LINE relelgtl1.1..LllWWi EQ. 18" SQ. BOXED COL. W/ STONE VENEER PER DETAIL 11/A7.0 - HT. PER ELEVATIONS CONCRETE STOOP Bedroom 2 PED. SINK RAILING ZERO CLEARANCE F.P. W/ OUTSIDE AIR SUPPLY HEARTH Great Room 24"x30" CRAWL ACCESS PANEL EQ. ROD & SHELF tilili!i!i!i!i!i!Qi!i!i!1►ZI Main Floor Plan SCALE: 1/4" = HIGH WALL 0 0 0) DOOR SCHEDULE 0 Mark E>tposure Qty Nominal Size Door Type Frame Remarks a s Width Height Thick. Mat. Fin. Mat. Fin. 100 EXT 1 3 0 6 8 13/4 SC STN WD I STN Entry door w/ lite 101 EXT E 1 3 0 6 8 13/4 SC PNT WD PNT W/ self closing hardwr 102 EXT 1 2 8 6 8 13/4 WD PNT WD PNT Garage man door 103 EXT 3 6 0 6 8 - VIN 1 FACT VIN € FACT Patio sliding door 104 EXT 1 16 0 7 0 - - l _ _ _ Garage roll -up door 105 INT 8 2 6 6 8 13/8 WD PNT WD PNT 106 INT 1 2 8 6 8 13/8 WD 1 PNT WD ! PNT 107 INT 2 (2)-2 4 6 8 13/8 WD ! PNT WD PNT French door w/ lite 108 INT ! 2 (2)-2 6 6 8 13/8 WD 1 PNT WD PNT French door 109 INT I 2 (2)-2 6 6 8 13/8 WD PNT WD j PNT By-pass doors 110 INT 1 (2)-2 6 6 8 - WD PNT WD E PNT Bi-fold doors (Pantry) GARAGE WALL BELOW LINE OF ROOF BELOW 40'-0" �J WINDOW SCHEDULE O Mark QtyNominal Size T yp e Frame Rating Remarks Width Height Mat. Fin. t u_ U-Fact. Solar A 1 1 3 5 0 FXD } > Entry side lite B . 1 4 9 1 6 FXD Transom above door C j 1 2 0 2 6 FXD Transom D 2 20 50 FXD E 12 2 6 4 0 SH F I 9 30 40 SH G 3 5 30 50 SH H 1 4 0 3 6 SLDR i Above double sink J 1 1 4 0 4 0 FXD 1 Above stair landing K 5 3 0 4 0 FXD At Great Rm popout L 5 3 0 2 6 FXD j At Great Rm popout M 2 4 0 3 0 FXD Master Suite Relite 111-9" 11'-5" 5.-" 11'-6" 6'-2/4" 5'-63/4" 0 O) N annnnn62666624 • • • • • • • • • • • • • • • • •� • • • • • •, 2'-53/2" 14.44444 EQ. hJ6.4666,L21 Bedroom 3 6'-1" 3'-8" 3'-5" EQ. Bedroom 4 7'-6/2" w1 GWB SHELF BELOW X N 00 404 .1L.. ROD & SHELF • 96" VANITY Bath CAB. W/ LAUNDRY CHUTE 3'-0" El 60" R.O. 60" x 30" TUB w/ SHWR °) • ROD & SHELF 4 5'-9" 4 9 SHF W.I.C. 5._9,. (V 109 0 Open to Below IvN 1, ,I R. & S. 22"x30" ATTIC ACCESS PANEL 60" R.O. L 6'-1" w1 ----r Linen RAILING — 5'-6" RAILING a 7" f 0 M DN VAULTED CEI Loft 10'-9" v 6'-11" SHF Aml 0 ti 4'-113/2" 3'-0" QMaster Bath N 110001 3-884" 'I 1'-0" v) 0 0 C4 11./its1i1...11.1.0!.!!i!i!11.1il.1•1!111.1.1.99.0411.1.. !1 7'-33/4" CV Master Suite o Deck 6'-10Y4 13'-6" 6-73 " 4 L. 4'-13/4" ♦ Open to Below GWB SHELF BELOW 3.-42.. 3.-42" 15'-6" 4'-71/4" .0.01411, • • 40'-0" Upper Floor Plan SCALE: 1/4" = 1'-0" Floor Plan General Notes 1. All outside and inside dimensions are to the face of studs (unless noted otherwise on plans.) 2. Written dimensions take precedence over scaled dimensions. 3. For light fixture types and locations see electrical and mechanical plans. 4. All floor finishes are exposed colored concrete. 5. All vents to exterior. 6. All exterior doors shall be openable from inside without use of keys. 7. See reflected ceiling plans for smoke detector and exhaust fan locations. 8. Garage ceilings to have one layer of %" type 'X' GWB. 9. Provide cont. handrail at stairs a min. of 1-1/2" away from wall. 10. Handrail ends shall be returned or shall terminate in newel posts or safety terminals 11. FIRE STOPS: Fire blocking is required in all stud walls at ceilings & floor levels. The vertical distance between blocking shall not exceed 10 ft. 12. All tubs and showers: • limit shower flow to 2.5 g.p.m. • waterproof wall to within 70" above drain inlet. • vapor barrier behind GWB Wall Schedule w1 w2 -1 INTERIOR WOOD WALL: (U.N.0.) 2x4 WD STUDS @ 16" O.C. SINGLE TOP & BOT. PL. WITH Y2" GWB EA. SIDE (5/e' ON GARAGE SIDE) EXTERIOR WOOD WALL: (U.N.0.) 2x6 WD STUDS @ 16" O.C. Y2 GWB 0/ VAPOR BARRIER 0/ R-21 INSULATION WHERE SHOWN 7/15" OSB SHEATHING MOISTURE BARRIER (TYVEK) EXTERIOR FINISH (SEE ELEV.) Iw31 GARAGE WALL: 2x4 WD STUDS @ 16" O.C. 5/8' GWB 0/ VAPOR BARRIER 0/ R-15 INSULATION WHERE SHOWN 7/g. OSB SHEATHING MOISTURE BARRIER (TYVEK) EXTERIOR FINISH (SEE ELEV.) w4 HIGH WALL 2x6 VERSA -STUDS @ 16" O.C. W/ FIRE STOPS AT VERT. 10' O.C. MAX FOR OTHER NOTES SEE W2 EGRESS NOTE: ALL BEDROOM WINDOWS SHALL HAVE AN OPERABLE PANEL AT LEAST 5.7 s.f., SILL HEIGHTS SET AT 44" MAX. A.F.F. REVIEWED FOR CODE COMPLIANCE APPROVED NOV 17 2014 City of Tukwila BUILDING DIVISION APR 27.2llia RECEIVED CITY OF TUKWILA SEP 18 2014 PERMIT CENTER REGISTERED 21620 84th Ave. S. Ste. 200 Kent, WA 98032 (253) 468-7696 www.ihbarchitects.com The drawings and plans set forth on this set as instrument of service are, and shall remain, the property of IHB Architects. Use of this drawing is limited to a specified project for persons named hereon. And for a construction of one building. Any use or reuse of said drawings is strictly prohibited without written permission of IFIB Architects W U z LU 0 W ct 0 z vJ 00 0) a 00 CO a 2 t0 n co O O LL N revisions: job No: 14-108 date: September 16, 2014 drawn by: David Goretoy A2.O 17'-3/" TOP PL. 9'-2" FIN. FLR 8'-13/" 8 TOP PL. 0'-0" FIN. FLR -0'-113/a " Eo 6" T&B 26'-3" O 6" T&B T.O.F. 17'-3/" TOP PL. 9'-2" FIN. FLR 8'-1 %" TOP PL. 0'-0" FIN. FLR -0'-113/4" TOP OF RIDGE Front Elevation - North SCALE: 1/4" = 1'-0" STEPS 12 Rear Elevation - South SCALE: 1/4" = 1'-0" Elevation Notes 1. All stone veneer, wood siding, trims, flashing, etc. to be installed per manuf. specifications. 2. For roof & drainage plan refer to Roof Plan 3. For more elevation datum marks refer to building and wall sections 4. Refer to Reflected Ceiling Plan for exterior light fixture locations 5. For window & door types and sizes refer to floor plans (assume window header height 6'-8" above finished floor U.N.O.) 6. All exposed DF or HF non -treated exterior timber framing shall be stained and weather sealed 7. All exterior trim and fascia to be 5/4 white -wood material. Elevation Keyed Notes REVIEWED FOR CODE COMPLIANCE APPROVED NOV 17 2014 City of Tukwila BUILDING DIVISION ASPHALT SHINGLES1 SEE SECTIONS AND DETAILS FOR FASCIA ROOF ASSEMBLY FOR GUTTER & DOWNSPOUT LOCATIONS SEE ROOF PLAN CEMENTITIOUS LAP SIDING, 6" EXPOSURE CEMENTITIOUS BOARD & BATTEN SIDING (BATTEN MAY BE CEDAR OR WHITE -WOOD) 12" BAND AT PERIMETER OF HOUSE AS SHOWN 4" VERTICAL TRIM, TYP. AT CORNERS 24" SQ. LOUVERED GABLE END VENT RIDGE VENT PER DETAIL ENTRY COLUMN. BASE DETAIL PER FINISHED GRADE LINE OF VAULTED CEILING (INSIDE) FIREPLACE EXHAUST TO OUTSIDE EXPOSED CONCRETE (MAINTAIN 6" MIN. ABOVE GRADE) 4" TRIM AT ALL WINDOWS & DOORS, U.N.O. ENTRY DOOR W/ SIDE LITE & TRANSOM ABOVE DECK & RAILING PER DETAILS ON SHEET A7.1 EXTERIOR WALL MOUNT LIGHT FIXTURE CULTURED STONE VENEER APR 2?. 2016 RECEIVED CITY OF TUKWILA SEP 1 g 2014 PERMIT CENTER 21620 84th Ave. S. Ste. 200 Kent, WA 98032 (253) 468-7696 www.ihbarchitects.com The drawings and plans set forth on this set as instrument of service are, and shall remain, the property of IHB Architects. Use of this drawing is limited to a specified project for persons named hereon. And for a construction of one building. Any use or reuse of said drawings is strictly prohibited without written permission of RIB Architects A3.0 Exterior Elevations revisions: job No: 14-108 date: September 16, 2014 drawn by: David Goretoy A3.0 TOP PL. 8'-8" BOT. OF DRMR BEAM 8'-1 %" TOP PL. FIN. FLR TOP OF RIDGE Right Elevation - West Left Elevation - East SCALE: 1/4" = 1'-0" Elevation Notes 1. All stone veneer, wood siding, trims, flashing, etc. to be installed per manuf. specifications. 2. For roof & drainage plan refer to Roof Plan 3. For more elevation datum marks refer to building and wall sections 4. Refer to Reflected Ceiling Plan for exterior light fixture locations 5. For window & door types and sizes refer to floor plans (assume window header height 6-8" above finished floor U.N.O.) 6. All exposed DF or HF non -treated exterior timber framing shall be stained and weather sealed 7. All exterior trim and fascia to be 5/4 white -wood material. Elevation Keyed Notes ASPHALT SHINGLES SEE SECTIONS AND DETAILS FOR FASCIA ROOF ASSEMBLY FOR GUTTER & DOWNSPOUT LOCATIONS SEE ROOF PLAN CEMENTITIOUS LAP SIDING, 6" EXPOSURE CEMENTITIOUS BOARD & BATTEN SIDING (BATTEN MAY BE CEDAR OR WHITE -WOOD) 12" BAND AT PERIMETER OF HOUSE AS SHOWN 4" VERTICAL TRIM, TYP. AT CORNERS 24" SQ. LOUVERED GABLE END VENT RIDGE VENT PER DETAIL ENTRY COLUMN. BASE DETAIL PER FINISHED GRADE LINE OF VAULTED CEILING (INSIDE) FIREPLACE EXHAUST TO OUTSIDE EXPOSED CONCRETE (MAINTAIN 6" MIN. ABOVE GRADE) 4" TRIM AT ALL WINDOWS & DOORS, U.N.O. ENTRY DOOR W/ SIDE LITE & TRANSOM ABOVE DECK & RAILING PER DETAILS ON SHEET A7.1 EXTERIOR WALL MOUNT LIGHT FIXTURE CULTURED STONE VENEER rREVIEWED F R CODE COMPLIANCE APPROVED NOV 17 2014 City of Tukwila BUILDING DIVISION APR 2.7.2016 RECEIVED CITY OF TUKWILA SEP 18 2014 PERMIT CENTER 21620 84th Ave. S. Ste. 200 Kent, WA 98032 (253) 468-7696 www.ihbarchitects.com The drawings and plans set forth on this set as instrument of service are, and shall remain, the property of IHB Architects. Use of this drawing is limited to a specified project for persons namcd hereon. And for a construction of one building. Any use or reuse of said drawings is strictly prohibited without written permission of IHB Architects revisions: job No: 14-108 date: September 16, 2014 drawn by: David Goretoy A3.1 BEYOND Foyer Great Room Bedroom 3 %' TYPE 'X' GWB CEIL., FIRE -TAPED ONLY 2 Car Garage Laundry Building Section SCALE: 1/4" = 1'-0" Dining iglattoet.to TOP PL. FIN. FLR' 8'-13/6" TOP PL. FIN. FLR Master Suite BEYOND Deck Patio Building Section SCALE: 1/4" = 1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED NOV 17 2014 City of Tukwila BUILDING DIVISION 17'-33/a" TOP PL. 9'-2" FIN. FLR 8'-13/a" TOP PL. 0'-0" FIN. FLR -0'-113/4" T.O.F. 1- I Master Suite 2 Car Garage L- J Building Section Stairs STAIR DETAILS SCALE: 1/4" = 1'-0" SIM. Building Section SCALE: 1/4" = 1'-0" A4.0 FP BEAM / HEADER PER FRAMING PLANS CONCRETE SLAB - SEE FND PLAN DOOR PER FLOOR PLAN DECK ASSEMBLY: 5/4" x 4" CEDAR DECKING 0/ FLUID APPLIED MEMBRANE 0/ PLYWOOD, FLASH AND SEAL AS REQ'D 2x JOISTS @ 16" O.C. FLOOR ASSEMBLY: 23/32" OSB T. & G. FLR'G, GLUE AND SCREW TJI JOISTS PER FRAMING PLAN (R-30 BATT INSUL. ABV. GARAGE ONLY) 1/2" GYP. BOARD (5/8" IN GARAGE AREA) CRAWLSCAPE FLOOR ASSEMBLY: 15/32" OSB T. & G. FLR'G, GLUE AND SCREW TJI JOISTS PER FRAMING PLAN R-30 BATT INSULATION REFER TO FLOOR FRAMING PLAN & DETAILS ON SHEET A7.1 SEE FLOOR FRAMING PLAN & DETAILS ON SHEET A7.0 FOUNDATION - SEE FOUNDATION PLAN FIREPLACE - PROVIDE 5/8" TYPE 'X' GWB BEHIND FIREPLACE. EXHAUST FAN TO OUTSIDE WALL WALL FURRING 2x GWB OR PLY NAILER - INSTALL WHERE NECESSARY CI OVERBUILD FRAMING PER FRAMING PLAN RB RIM BOARD PER FRAMING PLAN ROOF ASSEMBLY: FIBERGLASS / ASPHALT SHINGLES CLASS A 5" EXPOSURE 15# ROOFING FELT 15/32" APA RATED ROOF SHEATHING OR OSB PRE -MANUFACTURED TRUSSES (SEE ROOF FRAMING) R-49 BATT INSULATION 6 MIL VAPOR BARRIER Y" GYPSUM BOARD CEILING ENTRY ROOF ASSEMBLY: FIBERGLASS / ASPHALT SHINGLES CLASS A 5"EXPOSURE 15# ROOFING FELT 15/32" APA RATED ROOF SHEATHING OR OSB PRE -MANUFACTURED TRUSSES (SEE ROOF FRAMING) SOFFIT BOARD CEILING WND WINDOW PER FLOOR PLAN Wall Schedule w1 w2 INTERIOR WOOD WALL: (U.N.O.) 2x4 WD STUDS @ 16" O.C. SINGLE TOP & BOT. PL. WITH Y2" GWB EA. SIDE (% ON GARAGE SIDE) EXTERIOR WOOD WALL: (U.N.O.) 2x6 WD STUDS @ 16" O.C. Y2' GWB 0/ VAPOR BARRIER 0/ R-21 INSULATION WHERE SHOWN 746" OSB SHEATHING MOISTURE BARRIER (TYVEK) EXTERIOR FINISH (SEE ELEV.) w3 w4 GARAGE WALL: 2x4 WD STUDS @ 16" O.C. 5/8" GWB 0/ VAPOR BARRIER 0/ R-15 INSULATION WHERE SHOWN 7A6" OSB SHEATHING MOISTURE BARRIER (TYVEK) EXTERIOR FINISH (SEE ELEV.) HIGH WALL 2x6 VERSA -STUDS @ 16" O.C. W/ FIRE STOPS AT VERT. 10' O.C. MAX. FOR OTHER NOTES SEE W2 APR 2121316 RECEIVED CITY OF TUKWILA SEP 1 8 2014 PERMIT CENTER REGISTERED E 21620 84th Ave. S. Ste. 200 Kent, WA 98032 (253) 468-7696 www.ihbarchitects.com The drawings and plans set forth on this set as instrument of service are, and shall remain, the property of IHB Architects. Use of this drawing is limited to a specified project for persons named hereon. And for a construction of one building. Any use or reuse of said, drawings is strictly prohibited without written permission of THB Architects revisions: job No: 14-108 date: September 16, 2014 drawn by: David Goretoy GABLE END LOUVER 8'-8" BOT. OF DORMER BEAM BEYOND Wall Section SCALE: 1/2" = 1'-0" A5.0 TOP PL. 0'-0" FIN. FLR Wall Section SCALE: 1/2" = 1'-0" EAVE 17'-33/6" TOP PL. 9'-2" FIN. FLR 8'-13/" TOP PL. 0'-0" Wall Section SCALE 1/2" A5 0 2 = 11-0 FIN. FLR 12 FL2 Wall Section SCALE: 1/2" = 1'-0" OF RB WND Section Keyed Notes BEAM / HEADER PER FRAMING PLANS CONCRETE SLAB - SEE FND PLAN DOOR PER FLOOR PLAN DECK ASSEMBLY: 5/4" x 4" CEDAR DECKING 0/ FLUID APPLIED MEMBRANE 0/ PLYWOOD, FLASH AND SEAL AS REQ'D 2x JOISTS @ 16" O.C. FLOOR ASSEMBLY: 23/32" OSB T. & G. FLR'G, GLUE AND SCREW TJI JOISTS PER FRAMING PLAN (R-30 BATT INSUL. ABV. GARAGE ONLY) 1/2" GYP. BOARD (5/8" IN GARAGE AREA) CRAWLSCAPE FLOOR ASSEMBLY: 15/32" OSB T. & G. FLR'G, GLUE AND SCREW TJI JOISTS PER FRAMING PLAN R-30 BATT INSULATION REFER TO FLOOR FRAMING PLAN & DETAILS ON SHEET A7.1 SEE FLOOR FRAMING PLAN & DETAILS ON SHEET A7.0 FOUNDATION - SEE FOUNDATION PLAN Fp FIREPLACE - PROVIDE 5/8" TYPE 'X' GWB BEHIND FIREPLACE. EXHAUST FAN TO OUTSIDE WALL WALL FURRING 2x GWB OR PLY NAILER - INSTALL WHERE NECESSARY OVERBUILD FRAMING PER FRAMING PLAN RIM BOARD PER FRAMING PLAN ROOF ASSEMBLY: FIBERGLASS / ASPHALT SHINGLES CLASS A 5" EXPOSURE 15# ROOFING FELT 15/32" APA RATED ROOF SHEATHING OR OSB PRE -MANUFACTURED TRUSSES (SEE ROOF FRAMING) R-49 BATT INSULATION 6 MIL VAPOR BARRIER Y2" GYPSUM BOARD CEILING ENTRY ROOF ASSEMBLY: FIBERGLASS / ASPHALT SHINGLES CLASS A 5" EXPOSURE 15# ROOFING FELT 15/32" APA RATED ROOF SHEATHING OR OSB PRE -MANUFACTURED TRUSSES (SEE ROOF FRAMING) SOFFIT BOARD CEILING WINDOW PER FLOOR PLAN Wall Schedule w1 INTERIOR WOOD WALL: (U.N.O.) 2x4 WD STUDS @ 16" O.C. SINGLE TOP & BOT. PL. WITH Y2" GWB EA. SIDE (%" ON GARAGE SIDE) EXTERIOR WOOD WALL: (U.N.O.) 2x6 WD STUDS @ 16" O.C. Yz" GWB 0/ VAPOR BARRIER 0/ R-21 INSULATION WHERE SHOWN %a" OSB SHEATHING MOISTURE BARRIER (TYVEK) EXTERIOR FINISH (SEE ELEV.) w3 w4 GARAGE WALL: 2x4 WD STUDS @ 16" O.C. 5/8" GWB 0/ VAPOR BARRIER 0/ R-15 INSULATION WHERE SHOWN e" OSB SHEATHING MOISTURE BARRIER (TYVEK) EXTERIOR FINISH (SEE ELEV.) HIGH WALL 2x6 VERSA -STUDS @ 16" O.C. W/ FIRE STOPS AT VERT. 10' O.C. MAX FOR OTHER NOTES SEE w2 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 17 2014 City of Tukwila BUILDING DIVISION APR 2! 2f1S RECEIVED CITY OF TUKWILA SEP 1$ 2014 PERMIT CENTER 21620 84th Ave. S. Ste. 200 Kent, WA 98032 (253) 468-7696 www.ihbarchitects.com The drawings and plans set forth on this set as instrument of service are, and shall remain, the property of IHB Architects. Use of this drawing is limited to a specified project for persons named hereon. And for a construction of one building. Any use or reuse of said drawings is strictly prohibited without written permission of IHB Architects revisions: job No: 14-108 date: September 16, 2014 drawn by: David Goretoy 12 12 Wall Section SCALE: 1/2" = 1'-0" 17'-3%" TOP PL. 9'-2" FIN. FLR 8'-13/" TOP PL. 12 Wall Section SCALE: 1/2" = 1'-0" A5.1 17'-3%" tjie TOP PL. L4 Ik FOR DECK CONNECTION DETAILS REFER TO SHEET A7.1 3'-6" RAILING Wall Section SCALE: 1/2" = 1'-0" SIM. REVIEWED FOR CODE COMPLIANCE APPROVED NOV 17 2014 City of TuKwila BUILDING DIVISION 17'-33/" TOP PL. 9'-2" FIN. FLR 8'-13A" TOP PL. 0'-0" FIN. FLR i Wal l Section 4 SCALE: 1/2" = 1'-0" } Section Keyed Notes BEAM / HEADER PER FRAMING PLANS CONCRETE SLAB - SEE FND PLAN DOOR PER FLOOR PLAN DECK ASSEMBLY: FLUID APPLIED MEMBRANE 0/ PLYWOOD, FLASH AND SEAL AS REQ'D 2x JOISTS @ 16" O.C. FLOOR ASSEMBLY: 23/32" OSB T. & G. FLR'G, GLUE AND SCREW TJI JOISTS PER FRAMING PLAN (R-30 BATT INSUL. ABV. GARAGE ONLY) 1/2" GYP. BOARD (5/8" IN GARAGE AREA) CRAWLSCAPE FLOOR ASSEMBLY: 13/32" OSB T. & G. FLR'G, GLUE AND SCREW TJI JOISTS PER FRAMING PLAN R-30 BATT INSULATION FOUNDATION - SEE FOUNDATION PLAN REFER TO FLOOR FRAMING PLAN & DETAILS ON SHEET A7.1 SEE FLOOR FRAMING PLAN & DETAILS ON SHEET A7.0 FIREPLACE - PROVIDE 5/8" TYPE 'X' GWB BEHIND FIREPLACE. EXHAUST FAN TO OUTSIDE WALL WALL FURRING 2x GWB OR PLY NAILER - INSTALL WHERE NECESSARY OVERBUILD FRAMING PER FRAMING PLAN RIM BOARD PER FRAMING PLAN ROOF ASSEMBLY: FIBERGLASS / ASPHALT SHINGLES CLASS A 5" EXPOSURE 15# ROOFING FELT 15/32" APA RATED ROOF SHEATHING OR OSB PRE -MANUFACTURED TRUSSES (SEE ROOF FRAMING) R-49 BATT INSULATION 6 MIL VAPOR BARRIER %" GYPSUM BOARD CEILING ENTRY ROOF ASSEMBLY: FIBERGLASS / ASPHALT SHINGLES CLASS A 5" EXPOSURE 15# ROOFING FELT 15/32" APA RATED ROOF SHEATHING OR OSB PRE -MANUFACTURED TRUSSES (SEE ROOF FRAMING) SOFFIT BOARD CEILING WINDOW PER FLOOR PLAN Wall Schedule w1 w2 INTERIOR WOOD WALL: (U.N.O.) 2x4 WD STUDS @ 16" O.C. SINGLE TOP & BOT. PL. WITH Y" GWB EA. SIDE (%' ON GARAGE SIDE) EXTERIOR WOOD WALL: (U.N.O.) 2x6 WD STUDS @ 16" O.C. Y2"GWB 0/ VAPOR BARRIER 0/ R-21 INSULATION WHERE SHOWN %e" OSB SHEATHING MOISTURE BARRIER (TYVEK) EXTERIOR FINISH (SEE ELEV.) AT TOP AND BOT. STAIRS 7 TREADS @ 11" = 6'-5" 8 RISERS @ 67/6" = 4'-7" w3 rw7ti 4'-0 1/2" GARAGE WALL: 2x4 WD STUDS @ 16" O.C. 5/8" GWB 0/ VAPOR BARRIER 0/ R-15 INSULATION WHERE SHOWN %e OSB SHEATHING MOISTURE BARRIER (TYVEK) EXTERIOR FINISH (SEE ELEV.) HIGH WALL 2x6 VERSA -STUDS @ 16" O.C. W/ FIRE STOPS AT VERT. 10' O.C. MAX FOR OTHER NOTES SEE w2 NOTE: FOR OTHER STAIR & RAILING DETAILS REFER TO SHEET A7.1 Z 0 .53 2x8's 2x4 STRINGER LEDGER 2x4 STUDS @ 16" O.C. 1 1 2x4 KICK PLATE BLOCKING UNDER LANDING BEARING WALL APR2''It2016 4'-7" LANDING RECEIVED CITY OF TUKWILA SEP 18 2014 PERMIT CENTER tair Section SCALE: 1/2" = 1'-0" REGISTERED A:P ' I C: 21620 84th Ave. S. Ste. 200 Kent, WA 98032 (253) 468-7696 www.ihbarchitects.com The drawings and plans set forth on this set as instrument of service are, and shall remain, the property of IIIB Architects. Use of this drawing is limited to a specified project for persons named hereon. And for a construction of one building. Any use or reuse of said drawings is strictly prohibited without written permission of IHB Architects revisions: job No: 14-108 date: September 16, 2014 drawn by: David Goretoy 5:12 SLOPE TO DRAIN V-2" EAVE 9:12 SLOPE TO DRAIN 5:12 SLOPE TO DRAIN RIDGE 5:12 SLOPE TO DRAIN NOTE: SEE SHEET A1.1 FOR DOWNSPOUT TERMINATIONS TO STORM SYSTEM Roof Plan SCALE: 1/4" = 1'-0" ROOF DRAINAGE AREA: 337 DRAINAGE REQ'D: 0.94 SQ IN DRAINAGE PROVIDED: 6.0 SQ IN (1) 2X3 DS ROOF DRAINAGE AREA: 503 DRAINAGE REQ'D: 1.40 SQ IN DRAINAGE PROVIDED: 6.0 SQ IN (1) 2X3 DS ROOF DRAINAGE AREA: 280 DRAINAGE REQ'D: 0.78 SQ IN DRAINAGE PROVIDED: 6.0 SQ IN (1) 2X3 DS ROOF DRAINAGE AREA: 675 DRAINAGE REQ'D: 1.88 SQ IN DRAINAGE PROVIDED: 6.0 SQ IN (1) 2X3 D5 Roof Keyed Notes ASPHALT SHINGLES CLASS A, 5" EXPOSURE OVER 15# ROOFING FELT 4x4 MIN. GUTTER W/ HANGERS AS REQ'D 2x3 DOWNSPOUT W/ STRAPS TO WALL AS REQ'D GABLE END WALL ATTIC ACCESS PANEL PER DETAIL SOFFIT VENTING - SEE DETAIL RIDGE VENT PER DETAIL ROOF VENT W/ MIN. 49 SQ. IN. OF FREE AREA. (TYP. OF 4) ROOF ACCESS PANEL OR LADDER DIRECTIONAL SLOPE ARROW BUILDING OUTLINE GUTTER DOWNSPOUT RIDGE VENT FOR CODE COMPLIANCE APPROVED NOV 172014 BuLDNGDI DIVISION ROOF DRAINAGE AREA: 50 DRAINAGE REQ'D: 0.14 SQ IN DRAINAGE PROVIDED: 6.0 SQ IN (1) 2X3 DS ROOF DRAINAGE AREA: 300 DRAINAGE REQ'D: 0.83 SQ IN 4 DRAINAGE PROVIDED: 6.0 SQ IN (1) 2X3 DS Drainage Calculations APR 27,216 N.T.S. RECEIVED CITY OF TUKWILA SEP 18 2014 PERMIT CENTER 21620 84th Ave. S. Ste. 200 Kent, WA 98032 (253) 468-7696 www.ihbarchitects.com The drawings and plans set forth on this set as instrument of service are, and shall remain, the property of IHB Architects. Use of this drawing is limited to a specified project for persons named hereon. And for a construction of one building. Any use or reuse of said drawings is strictly prohibited without written permission of IHB Architects revisions: job No: 14-108 date: September 16, 2014 drawn by: David Goretoy A6.O VENT BLOCKING SIMPSON H1 @ EA. TRUSS ROOF FINISH PER PLAN FASCIA AT DIFFERENT ROOF SLOPE TO ALIGN ALUMN. GUTTER & DOWNSPOUT 5/4 FASCIA 2'-0" AT 5:12 SLOPE Y2' MAX. OVERHANG ON CAP Y4" BEAD OF SILICONE CAULKING SHT'G PER PLANS 2x BLOCKING @ RIDGE 9'-2" FIN. FLR. RIM BOARD PER PLAN TOP PL. 12 / 9 /12 7 5 PRE-ENG. TRUSSES TOP PL. R-49 BATT INSULATION BAFFLE WALL PER FLOOR PLANS 4r Eave Detail SCALE: 1" = 1'-0" SHINGLE CAP COR-A-VENT OR SIMILAR ACTIVE WEATHER FOIL ROOF UNDERLAYMENT PRE-ENG. TRUSS Ridge Vent Detail SCALE: 2" = 1'-0" WALL PER FLOOR PLANS FLOOR SYSTEM PER PLAN CONT. INSULATION AT FLOOR ENDS - TYP. Typical Floor End Detail o'-o" FIN. FLR. RIM BOARD PER FRM'G PLAN 2x6 TREATED SILL W/ A.B. @ 32" O.C. SLOPE GRADE FROM BUILDING 4" DIA. PERF. FND DRAIN CONT. TO DRAIN SYSTEM, TYP. WRAP DRAIN ROCK W/ FILTER FABRIC, TYP. SCALE: 1" = 1'-0" WALL PER FLOOR PLANS FLOOR SYSTEM PER PLAN WASHED ROCK - TYP. #4 CONT. AT TOP #4 DOWELS 12x6 AT 1-STORY 15x6 AT 2-STORY (2) #4 CONT. EU Typical Foundation Detail A7.0 6 MIL VAPOR BARRIER BEAM PER PLAN PRE-ENG. TRUSS NOTE: AT POPOUT AREA, BEAR TRUSSES ON BEAM ONLY. PROVIDE TRUSS CAPACITY TO ALLOW POPOUT FURRING ATTACHMENT WRAP SIMPSON LSTA30 AT EVERY HORIZ. 2x8 TO WALL STUDS BELOW 2x8 RIM SIMPSON H1 @ EA. TRUSS TO BEAM BELOW SIMPSON A34 AT TOP PL. TO RIM AND TO HORIZ. 2x8'S 2'-0" POPOUT SIMPSON H16-2 AT EVERY TRUSS TO TOP PLATE SIM. EAVE HORIZ. 2x8's @ 16" O.C., ALIGN W/ WALL STUDS BELOW AND FILL W/ INSUL. Wall Pop -out Detail SCALE: 1" = 1'-0" FLOOR SYSTEM PER PLAN CONCRETE FLOOR SLAB PER PLAN u WALL OR BEAM PER PLAN A7.0 WALL PER FLOOR PLANS INVERT JOIST HANGERS AT CANTILEVERED JOISTS TO RIM RIM BOARD PER FRAMING PLAN Cantilevered Floor Detail -Int. o,-o" FIN. FLR. CO SCALE: 1" = 1'-0" DOOR PER PLAN • FOR OTHER NOTES SEE DETAIL ON LEFT Foundation Detail At Garage 2'-0" 2'-0" 2'-0" Y2" PLYWOOD INSUL. BAFFLE NAILED TO BOTTOM OF TRUSS CHORD (4 SIDES) COMPRESSED WEATHERSTRIPPING AS REQ'D ONE HOUR: 3/4' FIRE RETARDANT PLYWOOD (FRT) AS REQ'D 1'-8" (X 2'-6") WOOD TRUSS INSULATION SAME AS ATTIC INSUL. 3" MIN. WOOD TRIM AT PERIMETER Attic Access Hatch REVIEWED FOR CODE COMPLIANCE APPROVED NOV 17 2014 City of Tukwila BUILDING DIVISION MAX, HEIGHT 0' i FASTEN SHEATHING TO HEADER wrat 8D COMMON OR GALVANIZED SOX "NAILS IN 3M G€ 1D PATTERN AS SHOWN AND. at C. IN ALL,. FRAMING (STUDS, 8LOCKINQ, AND SILLS) TYPy, MANUFACTURED STONE 3/4' MAX. PCL STONE VENEER MORTAR SCRATCH COAT METAL LATH 2 LAYERS OF GRADE "D" BUILDING PAPER OR 1 LAYER OF DUPONT TYVEK STUCCO WRAP SCALE: 1" = 1'-0" 2'-0" APPROX. VENEER POINTING MORTAR JOINT A7.0 2x TREATED MUD PL. W/ (2) "DIA. A.B. PER PLATE 4x4 POST BOXED FRAME W/ 2x'S AND SHT'G WRAP BRACE TOP OF BOXED FRAME TO 4x4 POST: 2x6 W/ 16d COMMONS Boxed Column Detail 10 EXTENT OF HEADE. pOueLE:. PORTAL FRAME (TWO SPACED EXTENT OF. HEADER SIN LE PORTAL FRAME (I' 4F GRA= WALL PANEL) TO 1a' FASTEN TOP PLATE TO HEADER WITH TWO ROWS OF'160 SINKEIR NAILS AT 3` O.C, TYR. 1000 LB STRAP OPPOSITE SHEATHING IYa". 3R MIN. WIDTH 18`. FOR ONE STORY STRUCTURES MIN. WIDTH = 234* FOR USE Its THE FIRST OF TWO STORY STRUCT RE MIN 2x4 FRAMING 3/8* MIN. THICKNESS WOOD STRUCTURAL PANEL SHEATHING MIN.. 42001 B TIE -DOWN DEVICE. (EMI EDDEU 1P TO CONCRETE AND NAILED INTO FRAMING) SEE SECTION 230119,3.2. SCALE: 1" = 1'-0" A7.0 APR 2 7 2U'6 TYPICAL PORTAL FRAME CONSTRUCTION ;FORA PANEL SPLICE: gIF NEEDED), PANEL EDGES SHALL SE ICI'.EI , AND OCCUR` VATHIN 4" OF M1O HEIGHT. ONE ROW OF TYR SHEATFIINTi FRAMING.NAIUNC Ii REQUIRED. IF 2X4 SLOG ING IS U. ED, TH 12X4'S MUST BE NAILED TOGETHER WITH, 3181) SINKERS MIN 1000# TIE DOWN' DEVICE Garage Portal Frame Detail RECEIVED CITY OF TUKWILA NOV 07 2014 ,' PERMIT CENTER 21620 84th Ave. S. Ste. 200 Kent, WA 98032 (253) 468-7696 www.ihbarchitects.com The drawings and plans set forth on this set as instrument of service are, and shall remain, the property of IHB Architects. Use of this drawing is limited to a specified project for persons named hereon. And for a construction of one building. Any use or reuse of said drawings is strictly prohibited without written permission of 1HB Architects revisio ns: City Review Comments Nov. 6 2014 job No: 14-108 date: September 16, 2014 drawn by: David Goretoy reviewed by: 'mad Bahbah A7.0 SCALE: 1" = 1'10" A7.0 SCALE: 1" = 1'-0" A7.0 N.T.S. A7.0 guard posts may be located on either side of the outside joist guard post - (2)1/2" dia.Ihru- bolts and wasters 2" min. ii2" rain, and 5" max. 2" min. outside -joist stair guard is required for . . stairs with a total rise of 30** or more; see GUARD REQUIREMENTS for more information stair guard height 4" min. measured from nosing of step Openings for required guards on th sides of stain treads shall not .allow a sphere 4-3/8" to pass through. see FIGURE 24 for guard component attachment requirements SECTION *guard posts can be installed as shown in Figure 26 (between joists) if blocking is installed as shown Flow within 12" of each side of the post -.at First interior bay, provide 2x blocking at guard posts with hold-down anchors, attest blocking with 10d threaded nails top and bottom, each side Guard Post to Outside Joist Triangular opening shale not permit the passage of .a £" diameter sphere. Stair Guard Requirements 4x4 post, typical DO NOT NOTCH tnirtttar 2)12' t ru-bolts and washers N.T.S. ...r.."0'g ntaxrriurn spacing .,...... 2x6 or 5 4Ward • rail ca openings shall not allow the paste of a 4' diameter sphere N.T.S. rim joist or outside joist sloped joist hanger, a,. minimum download capacity of 625 Ibs see JOIST HANGERS for more requirements ATTACHMENT WITH HANGERS' Stair Stringer Attachment N.T.S. 2,. halt et, typical 2x4 top and bottom: attach to guard post with (2)8d threaded nails or (2)Ate wood screws 2 long on inside face attach ba ust rrs at top and bottom. with ( wood screw or (2)8d post from threaded nails with a54 omtosi diameter Railing Detail N.T.S. A7.1 lee FIGURE 24 for guard component attachment requirements rim joist hold-down anchor joist ----- minimum (2)1/2" diameter thru bolts and washers SECTION 2" min. 2-1/2" mirt. and 5 max: " min. hoid-down anchor s align guard post at joist lotions rim mist )l)ti hold-down anchor PLAN VIEW AT JOIST LOCATION PLAN VIEW BETWEEN JOISTS Guard Post to Rim Joist Fasten handra 1 fried per guard post MQUNTE TO GUARD nut ecttrer reoornmendatioit - " min. <2x blocking 4r to nosing' of stairs, typed `corrosion -resistant handrail hardware MOUNTED .ALL Handrail Mounting Types joists relit joist N.T.S. A7.1 secure decking to top of rim joist with 10d threaded nails or #10 x '; minimum wood screws a " o,c. —attach rim joist to end of oath joist With (3)10d threaded nails or () #1€ x 3" minimum wood stews End Deck Detail N.T.S. N.T.S. REVIEWED FOR CODE COMPLIANCE APPROVED NOV 17 2014 City of Tukwila BUILDING DIVISION A7.1 NONCIRCULAR CIRCU 1 311 J. '{3 Type 11 Perimeter: 4 - 4,4 14"_ min. .E tR RECESSED [R311.7.73 Type III Perimeter: >64" Handrail Grip Size floor sheathing nailing at. maximum on center to joist with bold down N.T.S. hold down or similar tension device Deck to House Connection N.T.S. APR 2 *. 201E .RECEIVED CITY OF TUKWILA SEP 18 2014 PERMIT CENTER STAT OF WASHINGTON ARCH I T c T S 21620 84th Ave. S. Ste. 200 Kent, WA 98032 (253) 468-7696 www.ihbarchitects.com The drawings and plans set forth on this set as instrument of service are, and shall remain, the property of IHB Architects. Use of this drawing is limited to a specified project for persons named hereon. And for a construction of one building. Any use or reuse of said drawings is strictly prohibited without written permission of IFIB Architects revisions: job No: 14-108 date: September 16, 2014 drawn by: David Goretoy A7.1 ELEC. MTR Storage 2 Car Garage %" TYPE 'X' GWB CEIL., FIRE -TAPED ONLY Laundry Dining Shop Kitchen Pantry Foyer Bedroom 2 Pwd Great Room Patio Main Floor Reflected Ceiling Plan SCALE: 1/4" = 1'-0" ROOF LINE BELOW Bedroom 3 Bath Master Bath Bedroom 4 ATTIC ACCESS PANEL Open to Below Linen Master Suite VAULTED DEL. Loft Open to Below Deck Upper Floor Reflected Ceiling Plan SCALE: 1/4" = 1'-0" RCP Notes 1. U.N.O. All ceilings are 8' high - coordinate with section sheets 2. Lighting not shown, Electrical permit under separate submittal RCP Legend (DI +co 110V SURFACE MOUNTED SMOKE DETECTOR-ICBO APPROVED SMOKE DETECTOR WITH CARBON MONOXIDE ALARM COMBO EXHAUST FANS (INTERMITTENT / CONTINUOUS) - KITCHEN FAN 100 CFM / 25 CFM (DOWNDRAFT EXHAUST IN RANGE) - BATHROOM FAN 65 CFM / 20 CFM - LAUNDRY FAN: CONTINUOUS OPERATION - WHOLE HOUSE FAN MIN. 70 CFM W/ A SONE RATING OF 1.0 OR LOWER (MAIN FLOOR GUEST BATH) ELECTRICAL PANEL & METER REVIEWED FOR CODE COMPLIANCE APPROVED NOV 17 2014 City of Tukwila BUILDING DIVISION APR 27.2016 .0.094ee40ri3: RECEIVED CITY OF TUKWILA SEP 1 2014 PERMIT CENTER REGISTERED A.ITEC` OF WASHINGTON HI TIS 21620 84th Ave. S. Ste. 200 Kent, WA 98032 (253) 468-7696 www.ihbarchitects.com The drawings and plans set forth on this set as instrument of service are, and shall remain, the property of IHB Architects. Use of this drawing is limited to a specified project for persons named hereon. And for a construction of one building. Any use or reuse of said drawings is strictly prohibited without written permission of IHB Architects revisions: job No: 14-108 date: September 16, 2014 drawn by: David Goretoy A8.0 BOLLARD 23'-0" 16'-2" TURNDOWN 18"x18"x6" CONC. PAD W/ (2) #4 BARS EA. WAY e {iee•°s•°or✓.F •fir•,:%a✓,[•'°:%•'•'q'o :✓ . ;°✓.y.'°. ✓✓. •h•,°f' O'"'•;a✓. o0 %°.✓'.ge••yP•'. '4`rFiogS' o✓ K...✓iA+.•. •.:.W3..4✓/A°•°•'.. . o va ...✓A .. °.❖.s. 'ra ;•,✓.Ae,•.•.s• 'ri •.C • ' 30" x 30" x 6" CONC. PAD W/ (3) #4 BARS EA. WAY W/ BLKOUT VfIREF 8°.0S1:11.ii 6'nSa',ss enilif&M goi.i qv aM,eepo•..,., 24" x 24" x 6" CONC. PAD W/ (2) #4 BARS EA. WAY 16" x 16" x 6" CONC. PAD W/ (2) #4 BARS EA. WAY 4'-8" NEC 250.52 Grounding Electrodes. A concrete encased grounding electrode is requir in all new concrete footings. The electrode shall consist of at least 20 feet of l" or larger reinforcement bar or Bare copper conductor not smaller than 4 AWG, and shall be located horizontally within that portion of a concrete foundation or footing that is in direct contact with the earth & encased by at least 2" of concrete. (NOTE: 20 foot rebar shall be one continuous piece tied alongside any vicinity footing rebar and shall protrude 8" min. above top of foundation wall near location of power panel.) Foundation Plan SCALE: 1 /4" = 1 `-0" IDENTIFY LOT LINES Lot lines shall be established on site and made visible to verify distance of building setbacks the from lot lines, at time of footing/foundation inspection, prior to pouring concrete. A survey may be required to verify lot lines. PLEASE NOTE: Setback(s) shall be calculated and measured from the buildings finish face or corner of the building nearest the property line and not necessarily measured from the exterior foundation. FLOOR SHEATHING 3 LAYOUT, PLACE LONG SPAN PERP. TO JOISTS OBELOW REVIEWED FOR CODE COMPLIANCE APPROVED NOV 17 2014 City of Tukwila` BUILDING DIVISI O VP Main Floor Framing Plan SCALE: 1 /4" = 1'-0" APR 212016 Foundation & Framing Notes 1. If no soils report is available, Assume minimum soil bearing capacity of 2000 psf, sandy loam and clay. Other soil conditions may require special provisions in foundation design. 2. All continuous foundation and footings are existing U.N.O. 3. All posts connected to concrete with Simpson CB or as noted 4. All wood within 1" of any concrete or within 6" of any exposed earth shall be of approved treated wood and/or shall have a protection barrier - see details. 5. Wall Sheathing: 7/16" OSB w/ 8d @ 6" o.c. panel edges, 12" o.c. field 6. Insure that all concentrated loads are continuous to foundation Legend tgl T.O.F. HDUX CONCRETE STEM WALL OVER FOOTING FOOTING LINE (STRIP FOOTING) CONTROUEXPANSION JOINT WOOD POST NEW CONCRETE PAD ELEVATION MARK DESIGNATOR (ALSO REFER TO ELEVATIONS AND SECTIONS) T.O.F. = TOP OF FOUNDATION WALL T.O.S. = TOP OF SLAB SLAB SLOPE DIRECTION ARROW INDICATES A HOLDOWN FLOOR JOIST Keyed Notes FOUNDATION CONTINUOUS FOOTING PER DETAIL 4/ A7.0 CONTROL JOINT, 24 TO 36 TIMES THE THICKNESS OF THE SLAB GARAGE FLOOR SLAB: 4" CONCRETE SLAB W/ 6x6x1Oga WWR AT MID -DEPTH 0/ 6 MIL VAPOR BARRIER 0/ 4" COMPACTED CRUSHED ROCK BASE 0/ UNDISTURBED NATIVE SUB -GRADE CONCRETE STOOP / SLAB: 4" CONC. SLAB 0/ 4" min. COMPACTED CRUSHED ROCK BASE FOUNDATION VENT 6" x 16" x 6" DEEP SLOPE CONCRETE SLAB AT 2% TO DRAIN (MAINTAIN 4" THICKNESS) POUR GARAGE CONC. SLAB OVER FOUNDATION TURNDOWN. MAINTAIN 4" min. THK 4" THICKENED SLAB, TURNDOWN 12" BELOW GRADE MAIN FLOOR FRAMING 0 11/2" VERSA -LAM RIM BOARD (MATCH DEPTH W/ FLOOR JOIST) 0 y32 T&G OSB SHEATHING W/ 8d @ 6" 0.C. EDGES, 12" 0.C. FIELD, GLUE & CREW CRAWLSPACE ACCESS BLOCKOUT AS REQUIRED PROVIDE BLOCKING BETWEEN JOISTS UNDERNEATH STAIR LANDING BEARING WALL Crawl Space Vent Area Calculations CRAWLSPACE AREA: 1,100 s.f. TOTAL VENTS = 7.33 s.f. / 0.67 s.f. = 11 VENTS Note: assuming vent size 16"x6" Sill Plate Anchorage 2. 3. 4. Sill plate shall be preservative pressure treated. Holes in sill plate shall be a min. of 1/32" to a max of 1/16'' larger than the bolt dia. Holes shall be treated with a 20% solution of copper naphthenate. 0 A MIN. OF (2) A.B. SHALL BE PROVIDED IN EACH SILL SECTION 0 SILL PLATE JOINT 0 ANCHOR BOLTS W/ 7" MIN. EMBED & 3"x3"x Y4" PLATE WASHER TYP. SEE STUD WALL CONST. SCHEDULE FOR SIZE & SPACING PROVIDE (1) A.B. EA. SIDE WHERE SILL PLATE IS BORDED, CUT OR NOTCHED MORE THAN Y3 THE PLATE WIDTH I I II II II RECEIVED CITY OF TUKWILA PERMIT CENTER REGISTER ARCHITECTS 21620 84th Ave. S. Ste. 200 Kent, WA 98032 (253) 468-7696 The drawings and plans set forth on this set as instrument of service are, and shall remain, the property of IHB Architects. Use of this drawing is limited to a specified project for persons named hcrcon. And for a construction of one building. Any usc or reuse of said drawings is strictly prohibited without written permission of IFIB Architects revisions: date: September 16, 2014 drawn by: David Goretoy ROOF SHEATHING LAYOUT, PLACE LONG SPAN PERP. TO TRUSSES 1'-0" RAKE FLOOR SHEATHING LAYOUT, PLACE LONG SPAN PERP. TO JOISTS FOR GARAGE PORTAL FRAMING SEE DETAIL 3Y8' x 10.5" GLB HDR 4X8 AT POPOUT Qy,6 AREA OPEN TO BELOW VA" x11/e"LVLJ 134"x117/8"LVL AREA OPEN TO BELOW 15'-6" WALL POPOUT AREA SEE SECTION RAILING POST TO BEAM, SEE SHEET A7.1 FOR CONNECTIONS STAIR LANDING: 2x8 FLOOR JOISTS OVER 2x4 WALL W/ STUDS @ 16" O.C. 0 Upper Floor Framing Plan SCALE: 1/4" = 1'-0" r *MOM NV 17 2014 pity of Tukwila OLIIL INO DIVISION 1'-2" 1. SAVE N. MI I MI 3Y8" x 9" GLB HDR MN I UM 1'-2" ir EAVE Roof Framing Plan SCALE: 1/4" = 1'-0" N Framing Notes 1. All manufactured trusses shall be designed for loads prescribed in the general notes. Truss shop drawings shall be submitted with construction documents for permit. Submittals shall bear engr. seal registered in this state and be available on site for inspection. 2. Connect all trusses and rafters to walls or beams with "Simpson" H1 ties, both ends U.N.O. 3. All beams connected to posts with Simpson PC, CC or as noted. 4. Final roof truss design to be submitted to engineer of record prior to construction. 5. The truss manufacturer shall provide the drawings for metal -plate -connected wood trusses. 6. TJI floor joist manuf. shall provide all TJI joist connections where applicable 7. HEADERS: U.N.O. on plans assume 6x8 DF#2 at 2x6 walls and 4x10 DF#2 at 2x4 walls Framing Legend imumImom HEADER (BELOW FLOOR / ROOF LEVEL) BEAM (AT FLOOR / ROOF LEVEL) WALL BELOW FLOOR ®® POINT LOAD (U.N.O. ASSUME 4X4 POST) SIMPSON HANGER BY JOIST / TRUSS MANUF. U.N.O. FLOOR JOIST PRE-ENGINEERED TRUSSES OVERBUILD FRAMING - RIDGE BOARD & 2x6 WOOD RAFTERS @ 24" O.C. E Framing Keyed Notes FLOOR FRAMING 117/3" TJI 110 FLOOR JOISTS @ 16" O.C. 117/" TJI 230 FLOOR JOISTS @ 12" O.C. TJI END BOCKING @ 24" O.C. 11/2" VERSA -LAM RIM BOARD (MATCH DEPTH W/ FLOOR JOIST) 2x12 WOOD STRINGERS (TYP. OF 3 PER STAIRCASE) INTERIOR BEARING WALL BELOW CRAWLSPACE BLOCKOUT 2x8 TREATED WOOD JOISTS @ 16" O.C. 2x12 FLOOR JOISTS AT 24" O.C. W/ HANGERS ROOF FRAMING PRE-ENG. TRUSSES @ 24" O.C. PRE-ENG. HIP TRUSSES @ 24" O.C. PRE-ENG. MONO TRUSSES @ 24" O.C. GABLE END TRUSS PRE-ENG. GIRDER TRUSS FOR TOP CHORD SLOPE — REFER TO ELEVATIONS & ROOF PLAN ROOF OVERBUILD FRAMING: 2x8 RIDGE BOARD W/ 2x6 RAFTERS @ 24" O.C. 0/ 2x8 BEARING PLATE, PLACE FLAT SIDE OVER PRE-ENG. TRUSSES W/ (2) 16d NAILS INTO EA. TRUSS TOP CHORD 2x OUTRIGGERS @ 24" O.0 ATTIC ACCESS PANEL PRE-ENG. KNEE TRUSSES @ 24" O.C. PRE-ENG. SCISSOR TRUSSES W/ 9:12 SLOPE TOP CHORD & 5:12 SLOPE BOT. CHORD APR 212010 RECEIVED CITY OF TUKWILA SEP 18 2014 PERMIT CENTER 415 REGISTERED A IJ . STATE OF WASHINUTUN SRC ITECT 21620 84th Ave. S. Ste. 200 Kent, WA 98032 (253) 468-7696 www.ihbarchitects.com The drawings and plans set forth on this set as instrument of service are, and shall remain, the property of IHB Architects. Use of this drawing is limited to a specified project for persons named hereon. And for a construction of one building. Any use or reuse of said drawings is strictly prohibited without written permission of IHB Architects revisions: job No: 14-108 date: September 16, 2014 drawn by: David Goretoy