Loading...
HomeMy WebLinkAboutPermit D14-0309 - BOEING #2-010 - VAULT ENCLOSUREBOEING #2-1O 8123 E MARGINAL WAY S D14-0309 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 0001600020 Permit Number: D14-0309 8123 EAST MARGINAL WAY S Project Name: BOEING #2-010 Issue Date: 10/8/2014 Permit Expires On: 4/6/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BOEING COMPANY THE PO BOX 3707 M/C 20-00 PROPERTY TAX DEPT, SEATTLE, WA, 98124 JOHN MURDOCH PO BOX 3707 M/C 89-14 , SEATTLE, WA, 98124 BOEING COMPANY, THE 100 N RIVERSIDE, M/C 5003-4027 , CHICAGO, IL, 60606-1596 BOEINC*294ML THE BOEING COMPANY Phone: (253) 657-0868 Phone: (312) 544-2535 Expiration Date: 1/18/2015 DESCRIPTION OF WORK: INSTALL STEEL STUD AND GYPSUM BOARD ROOM FOR ELECTRICAL VAULT ENCLOSURE. Project Valuation: $100,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: Type of Construction: IIIB Fees Collected: $2,577.02 Occupancy per IBC: F-1 Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2014 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: I hearby certify that I have read and e provisions of law and ordinances gove amine ing t Date: V° fit this permit and know the same to be true and correct. All is work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or loc .ws re:ulating construction or the performance of work. I am authorized to sign and obtain this developm ermi :nd agree to the conditions attached to this permit. Signatur_� � ,f/!(i(,` VIC aJC..I / /&ifii Date: f / "y ° Q IL{i Print Name ©q5 itik.ccr# This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with the recommendations given in the soils report. Special inspection is required. 7: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 8: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 9: Special inspection for sprayed fire-resistant materials applied to structural elements and decks is required. Special inspections shall be based on the fire -resistance design as designated in the approved construction documents. 10: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8-feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 11: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 12: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 13: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 14: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 15: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 16: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 32: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 19: The total number of fire extinguishers required for an extra hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (4A 40 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 17: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 18: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 20: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 21: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 22: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 23: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 24: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 28: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 26: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 25: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 30: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 29: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 31: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 33: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 27: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 34: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 35: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 1 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Building Permit No. -01 � 0) 01 Blanket Permit No. A' °j " 0 Date Application Accepted: Date Application Expires: (For office use only) BLANKET PERMIT TENANT IMPROVEMENT APPLICATION **Please Print** FEES: For office use only Amount Receipt No. I Date Building Permit Fee $ I ' 2`j Plan Review Fee $ �jll542 F, 0' I State Building Surcharge $ 4.50 I f' ' 4641 lei 2 $ 116 tii SITE INFORMATION: Valuation of Construction: 14��.60 in Co Assessor's Tax No.: OD O I (i O — 002 I " l! fIV(1� J4L) Suite Number: ? /0 Floor: 1 '1E11' COW, Tenant Name: �� rV���',� W,����/ /l y / J c, A,� �d � �,�y� �^ Description of work: ..1I`+`�l Ai.�jj 12 L %� t' & C 5 J 5oM17 �►odeti1 �� t�: pace? VittOt7C Ehf&v l Site Address: Per the International Building Code — 2012 Edition Existing feet) Construction Area (square feet) Type of Construction perIBCI Type of Occupancy per Building Use 1�` Floor �j(ssqquarre t 1 [ I �Q�J •I0 9 r± j /I�BeC / F- l / ,-(f 2 r f k1 Y/5 N 2'd Floor 3'4 Floor Floors thru 1. Will there be any structural work? If yes, please describe: 2. Will there be new rack storage? 3. Will there be a change in use? ❑ If yes, please explain: ❑ Yes 0 No art pF113 P 2.3 2���► ❑ Yes IA No Yes ig No If yes, a separate permit and plan submittal will be required. CE B PEAS 4. Existing fire protection: Igt Sprinklers 0 .... Automatic Fire Alarm ❑ .... None 5. Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes $ No If yes, please explain: H:\Applications\Fomn-Applications On Line\2013 Applications\Blankct Permit Tl Application - 7-2013.does Revised: July 2013 bh Page 1 of 3 PROPERTY OWNER Name: Tile 0/����db 6or�t,j%�l1Y Address: m obx 3 I v if / - 4 e:iV State: 1 JA City:�l Zile( 2 i CONTACT PERSON — person receiving all project communication Name: fiat./ tAt eff CompanyNam�tte:lye AG(.Fic-K- ✓ Address: pO, 9 //(3 6 �(/ /et s ! '' ••1 City: 1 W State: (�%'"l, Zipge,Z(/ Phone 33)tl�JT�1(/- ( (��3)J7 a! Email: %O �: �-Atoirrichboetvil.Colvi ARCHITECT OF RECORD Name: &Mae l(t /t I�pLi,(- "C Company Name: £ Pr of /(h! 7 tIJi 3( �Q Address: /f:,)/ tr. Ave J�z,.., ` co City: � der State:A. Zip::Qggb( 1 O Phone: �Cfu�` ✓ �z;. v -11 7x: Email: GENERAL CONTRACTOR/INFORMATION Company Name: TR( f,/�/L.o &j/i !lw Address: pt Da ecy 37.07. Ilk ,I$ City: : State:w- Zip: qg (Zz.10 f!M9) 607 - 4303 Fax(23)657--ei3C6 Contr Reg No.: ROEmicieN At,Date: el i fie/ i Tukwila Business License No.: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name:7P/�. ti.6 f 1 y 6l�%a Address: gax 5101. €'qc ei -p1 City: �G a State:_ Jil)c Zip: ?SL241 I hereby certify that I have read and examined this application and know the same to be true and correct, and I am authorized under Blanket Pe Signatur ee No. to apply for and obtain this permit. 204 Print Nam&" (1( :J Hotectr i Organization: Voe(l4 & 6i OG 512111e F Day Telephone00) 61 .-00 Mailing Address: Pa Bb X 3 7O Mk- kL 05 -14 -"k(11( W 9g121/ H:\Applicatio sWoms-Applications On Lire\2013 Applications\ Blanket Permit T1 Application - 7-2013.docx Revised: July 2013 bh Date: City state Zip or( OFT SAP 2 3 "14 PERMIT CEDER Page 2 of 3 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us BLANKET PERMIT AGREEMENT — Temporary Inspection card Plan Review No.: t ) "1 1`- OS Date Issued: 2` 1 ' 004 Blanket Permit Agreement No.: '5PA I 3 r 1 Project Name: iqtft rI '3725 ,et r /) ( Ag P�tt, k M Site Address: Vi/H t7 S Che i CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE — 206-431-2451 "X" REQUIRED INSPECTIONS DATE APPROVED INSPECTOR INITIALS PLANS DATE DATE(S) CORRECTION NOTICE ISSUED ✓1. Framing 2. Insulation 3. Suspended Ceiling 4. Lath and gypsum board fastening DO NOT PROCEED BEYOND THIS POINT UNTIL THE BUILDING PERMIT IS ISSUED. PERMIT MUST BE PICKED UP WITHIN 24 HOURS OF NOTIFICATION THAT THE PERMIT IS READY. CONTRACTOR/APPLICANT BEGINS WORK AT THEIR OWN RISK PER THE TERMS OF THE BLANKET PERMIT AGREEMENT. INSPECTIONS: 1. FRAMING — After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 2. INSULATION — After framing approval, but before insulation of wallboard. Baffles must be installed to keep attic ventilation points clear. 3. SUSPENDED CEILING — Fasten diffusers, lights and seismic bracing. 4. LATH AND GYPSUM BOARD FASTENING — Prior to taping (I.B.C. Section 109.3.5 — Fire Rated Assemblies) 5. PLAN CHECK INSPECTION — Immediately after the Tenant Improvement Permit is picked -up by the applicant. Work may not proceed until the City inspector delivers the plans and new inspection card to the site. This inspection should be scheduled at the Permit Center when the permit is obtained. X Construction will not proceed past required inspections. X The Building Permit and approved plans shall be picked -up by the applicant within 24 hours of notification that the permit is ready. Failure to do so may result in a stop work order. X Construction may not deviate from that shown on the plans as submitted at time of application. X All corrections shall be made within three (3) days of notification by the Building Inspector. X No more than 30 days shall elapse between the last required inspection and the "Building Final." X Unauthorized occupancy and/or use of the remodeled area shall not occur until the Building Inspector completes the "Building Final," which takes place after the Building Permit and Permanent Inspection Card has been issued. X The City reserves the right to stop work at any time that in its judgment the work presents a safety problem, warrants a building permit prior to continuing work, is not proceeding according to approved plans, or otherwise would not qualify for consideration under the blanket permit process. X The following work is not covered under the blanket permit process. This work shall not start until approvals and permits are obtained through the applicable agencies, under their normal process: - Electrical City of Tukwila Building Department - 206-431-3670 Plumbing and Gas Piping City of Tukwila Building Department — 206-431-3670 Fire Protection City of Tukwila Fire Department — 206-575-4404 - Mechanical City of Tukwila Building Department — 206-431-3670 Rack Storage City of Tukwila Building Department — 206-431-3670 THIS IS A TEMPORARY INSPECTION CARD ONLY AND WILL BE REPLACED BY A PERMANENT INSPECTION CARD WHEN THE BUILDING PERMIT IS ISSUED. SEP 2 3 2014 PERMIT CENTER HAApplications\Fomu-Applications On Line\2010 Applications \8.2010 Blanket Permit Inspection Card.doc Created: 12-2008 Revised: 8-2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: lint:/Iwww•4ilkwilaWd.gov BLANKET PERMIT AGREEMENT — Architects Statement Plan Review No.: 1 0 Blanket Permit Agreement No.: peA I 2 - O ©Q I Project Name: y,IM% 35- e,,iTx/STltaa7) Site Address: 7756 eltsr 1 6/ Mt- tam' ) , 7ZA4ci A ,A fko8 Is any part of the work proposed under this application include 14 Yes 0 No structural work or affect structural components of the building? If yes, has the structural work been authorized by the Tukwila. Yes ❑ No Building Official to be included in this application? Does the proposed work comply with the requirements of Al Yes ❑ No the International Building Code (2012 Edition) Chapter 10, Means of Egress? If no, please explain: Will any special inspections be required per Chapter 17 Al Yes ❑ No in the International Building Code (2012 Edition)? 11 If yes, list specific inspections: Air /,J517tu k trot b - grc.rs deJ U6 itgeralmel eelJsrv2iActioi) Asa result of this proposal, does the parking meet the ❑ Yes No requirements of the Tukwila Zoning Code? If no, please explain deficiency: rIdtt 15 Ae Ci/Aa>t6 7?r i° •�69--- As A Zeersw-t of air S P*Poe m ARCHITECT/ENGINEER Signature o Print Name: Err r G 05?6IA Organization: Co iw4 'F..NO . Phone: Zito 602.f --0 7 r7 Mailing Address: lbot 5+"` Av6 sf'e R60 Wit•, rt- WAcity ggto l saw sEP 2 3 2 Vk ifeRtor H.AWpplbetlonsWerms•ApplintiomOnLiesi2013 ApplicetionMisoket Pe ndtArchitectStareaeoe-7-2013.docx (rated: 12.20011 D.4 .t• 7.71111 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT I QUANTITY PermitTRAK I PAID $2,577.02 D14-0309 Address: 7755 EAST MARGINAL WAY S Apn: 0001600020 $2,577.02 DEVELOPMENT $2,501.36 PERMIT FEE R000.322.100.00.00 0.00 $1,513.25 PLAN CHECK FEE R000.345.830.00.00 0.00 $983.61 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $75.66 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R3132 R000.322.900.04.00 0.00 $75.66 $2,577.02 Date Paid: Tuesday, September 23, 2014 Paid By: JOHN MURDOCH Pay Method: CREDIT CARD 043910 Printed: Tuesday, September 23, 2014 1:22 PM 1 of 1 CSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. A CITY OF TUKWILA BUILDING DIVISION 6300 Southcenterlvd,, #100, Tukwila. WA 98188 (206) 431-367C4 Permit Inspection Request Line (206) 438-9350 D tzt -030ci Project: \ 9.e A Ai, 2 - 1 (i) Type of inspection: gu--,le-)C.A(.,7 , NJ AL, Date COO: Mitivt_ Address: 1 '2- 3 ii-- „NAA.V-, i')k 1.- Special Instructions: a 60-- \J"-) 11- 1 CIttli -5 Pe 64 4-1/ e (X-', 0 7 Date Wanted: 1 - 2.. -)4. Requester: 'Phone No: j.._tp 6 —2 q 3 - c) (o i4 aiApproved per applicable codes. ElCorrections required prior to approval, COMMENTS: rr-,M Tto et,k, pC emire inspror: Date: 7-- 11144 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be • paid at 6300 Southcenter Blvd.. Suite 100, Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 F :(Z06) 431-3670 } Permit Inspection Request Line (206) 431-2451 91(4-fv1,00 Project: V9oLi ot, -t 2 -1:� Type of Inspection: Na I : ins, Address: 11 i ki %.)C Date Called: ` o 1 f, �— Special Instructions: JO¥' d cb Ct II 10— tc 9 -1 D hl'; V Otkl Date Wanted: , t! l Z a.mJ :m. Requester: ii Phone No: 1,11,0 A Approved per applicable codes. Corrections required prior to approval COMMENTS: ) / A...- l- / V (k_ / .-1.) r P- \K\ A -- Inspector: Date REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. w SEATTLE FIRE DEPARTMENT FIELD INSPECTOR'S FILE NOTES You must call at least 72 hours prior to inspection [206] 386-1443 Page No. 501i tea Date of Request / 0 " ZC-C- O.T. (l P.S. O.D. Date 1 0. 3f. l C- 1FINAL OK Address �f 7' 5 /%A i Amtz 6,0/ Building or Occupant goer k% Li -n1r 2 Atrz,c lL0c} Z - / o Floor No. 1 Total Floors PR No(s). Lig Z?j 5— Jl ( '- c-=-7z g- 1 —a ors 7-0 Cep IZA/S ❑ F/A ❑ R/H ❑ U/G ❑ F/P REQUIRES -3 7.< Reinspection Audibility Invoice ,Floor Correction(s) Needed Date OK M1W 1 hf Flo 2 _intE^ W oY ' f% /fir_.r tom- 7dal I Z- `f Test r Name, C6mpany, Phone, SCP & Expiration Date (-r'J SFD Inspector Name MAYES TESTING ENGINEERS, INC. October 21, 2014 City of Tukwila Building Department 6200 South Center Blvd Tukwila, WA 98188-8188 Attention: Building Official Re: Boeing Seattle Plant II Electrical Upgrades 7755 East Marginal Way S Tukwila, WA Project No. L14197 Gentlemen, Final Letter Permit No. D14-0309 Seattle Office 20775 Cedar Valley Road 5-110 Lynnviood, WA98036 ph425.7429360 fax425.745.1737 Tacoma Office 10029 S. Tacoma Way Sute E-2 Tacoma, WA98499 ph 253.584.3/"d0 fzer253584.3707 P► tgandORice 7911 NE 33rd Drive sine 190 Portland, CR97211 ph 533231.7515 fax 503281./Sly This is to inform you that registered special inspections have been completed for this project as per our reports, copies of which have been sent to you. Special inspection was provided for: • Reinforced Concrete • Epoxy Grouted Anchor Bolts • Epoxy Grouted Reinforcing Steel To the best of our knowledge, all work inspected was either performed in accordance with, or corrected to conform to, the city approved drawings, or engineer approved changes. We trust this provides you with the information that you require. Should you have any questions please call us at 425/742-9360. Sincerely, Mayes Testing Engineers, Inc. ,„(" a__ Michael S. Dolder, P.E. Vice President PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0309 DATE: 09/23/14 PROJECT NAME: BOEING #2-10 SITE ADDRESS: �3 E MARGINAL WAY S X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building DivisionliArt Public Works ❑ Fire Prevention Structural 111 Planning Division Permit Coordinator n • PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 09/25/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/23/14 Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping ❑ PW ❑ Staff Initials: 12/18/2013 BOEING COMPANY, THE Page 1 of 9 Washington State Department of Labor & Industries BOEING COMPANY, THE Owner. or tradesperson MCNERNEY, W (JAMES) Principals MCNERNEY, W (JAMES), PRESIDENT 'LOHR, MICHAEL, SECRETARY WOLTER, CHRISTOPHER, TREASURER READ, PAUL, SECRETARY (End: 02/07/2013) SHRONTZ, F A, SECRETARY (End: 02/07/2013) GIVAN, B E, SECRETARY (End: 02/07/2013) KING, C G, SECRETARY (End: 02/07/2013) BEIGHLE, D P, TREASURER (End: 02/07/2013) COLLINS, T J, TREASURER (End: 02/07/2013) BUDINICH, T M, TREASURER (End: 02/07/2013) WOODARD, R B, TREASURER (End: 02/07/2013) CRUZE, D D, TREASURER (End: 02/07/2013) CONDIT, P M, TREASURER (End: 02/07/2013) Doing business as BOEING COMPANY, THE WA UBI No. 178 005 030 100 N RIVERSIDE CHICAGO, IL60606-1596 312-544-2535 Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties https://secure.lni.wa.gov/verify/Detail.aspx?UBI=178005030&LIC=BOEINC*294ML&SAW= 10/08/2014