Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D14-0312 - ANDOVER PARK BUILDING 1 - REROOF
ANDOVER PARK BLDG 1 1206 ANDOVER PARK E EXPIRED 03/28/2015 D14-0312 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 3523049075 Permit Number: D14-0312 1206 ANDOVER PARK E BLDG 1 Issue Date: 9/29/2014 Permit Expires On: 3/28/2015 ANDOVER PARK BLDG 1 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: GRAY CAT COLLECTIVE LLC 1940 124TH AVE NE STE A101 C/O SHEPHARD COM REAL ESTATE, BELLEVUE, WA, 98005 BARRY BERENDSEN 7157 GUIDE MERIDIAN , LYNDEN, WA, 98264-9499 SCHOLTEN ROOFING, INC. 7157 GUIDE MERIDIAN , LYNDEN, WA, 98264-9499 SCHOLI*211K5 Expiration Date: 5/8/2015 Phone: (877) 398-7100 BUILDING OWNER Phone: (360) 398-8484 DESCRIPTION OF WORK: REMOVE EXISTING SINGLE -PLY OVER BUR AND RECOVER EXISTING BUR WITH FR10 STRIPSHEET AND FS .060 TPO MEMBRANE. Project Valuation: $117,230.00 Fees Collected: $2,834.32 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: Occupancy per IBC: M Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2014 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: L(jiL Dato ` )—Y 1/ I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development rmit and agree to the conditions attached to this permit. Signature: r�w Date: \—z 9 Print Name: AAC,..?.� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate shall be provided to the building inspector. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0103 PRE-REROOF r CITY OF TUL . ILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. P Project No. CA 714 H Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: Tenant Name: King Co Assessor's Tax No.: /eLoPc, cP)e gcts PROPERTYOWNER Name:�(y �I�l 6,6i/Ckk__ N q ebi vc. Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: I, `-� 'c no tt-fAeN 7 C?6 `lv. L Address: `7 15 // p City: I 0State: Vl/k Zip:&2 Phone: IiltA Fax: -71_'q�r `7I bO "6o-�q�_jz57 Email: 1 Y'vtV\rp n �O�r— N,KrAk AS .kn. A1- GENERAL CONTRACTOR INFORMATION Company Name: \ Vlp\--A,,,\ .�1 •^ C Address: i ////�y�► t \ r��, �1- _ City: Mate-; n , v`�„t". vVG� Zip plc-�61 I Phone: Fax:. 6 C7 ` 67�.3g�.-7InU -5 g.g.�1 Contr Reg No.: I x Date: - • Tukwila Business License No.: ;c2_27/01-1-101-c- Suite Number: Floor: New Tenant: ❑ Yes ❑ .. No ARCHITECT OF RECORD Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: Engineer Name: Address: City: S Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: r f D , ,(,, n _," t " V � Address: City: State: Zip: H:\Applications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12 docx Revised: February 2012 bh Page 1 of 4 BUILDING PERMIT INFORMAT — 206-431-3670 Valuation of Project (contractor's bid price): $ l ) i 7,0 , 56 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): , 1,y\C +„c. � � k 6\ 'w1 ,5 Jos D(.) Will there be new rack storage? ❑ ....Yes ❑ ..No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC lst Floor 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 0 No If 'Yes ', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 PUBLIC WORKS PERMIT OE ,MATION — 206-433-0179 Scope of Work (please provide detailed information): Ca11 before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila 0 ...Water District # 125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate ❑ ... Highline ❑ ...Valley View ❑ ... Renton ❑ ...Sewer Availability Provided 0... Renton 0... Seattle Septic System: O On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34") ❑ .. Technical Information Report (Storm Drainage) ❑ .. Bond 0... Insurance 0... Easement(s) Proposed Activities (mark boxes that apply): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - No Disturbance ❑ .. Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 ❑ .. Total Cut ❑ .. Total Fill cubic yards cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water ❑.. ❑.. ❑.. ❑.. ❑... Geotechnical Report 0... Maintenance Agreement(s) ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) 0... Right-of-way Use - Profit for less than 72 hours 0... Right-of-way Use — Potential Disturbance ❑... Work in Flood Zone ❑ ... Storm Drainage . Abandon Septic Tank . Curb Cut . Pavement Cut . Looped Fire Line 75 57 ❑ .. Permanent Water Meter Size (1) ❑ .. Temporary Water Meter Size (1) ❑ .. Water Only Meter Size ❑ .. Sewer Main Extension Public ❑ .. Water Main Extension Public 15 17 77 WO # WO # WO # Private 0 Private ❑ 0... Grease Interceptor ❑... Channelization ❑ ... Trench Excavation 0...Utility Undergrounding (2) " WO # (3) " WO # (2) " WO # (3) " WO # 0 .. Deduct Water Meter Size 73 FINANCE INFORMATION Fire Line Size at Property Line 0 .. Water ❑ .. Sewer ❑ .. Sewage Treatment Monthly Service Billing to: Name: Number of Public Fire Hydrant(s) Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H:Wpplications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 3 of 4 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Signature: Print Name: NER OR AUTHORIZED AG NT: r•Q Date: bt- - 1 .( Day Telephone: 36 D, 0 ` QC 7)/ 6 Mailing Address: City State Zip H:\Applications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT I QUANTITY PermitTRAK I PAID $2,834.32 D14-0312 Address: 1206 ANDOVER PARK E BLDG 1 Apn: 3523049075 $2,834.32 DEVELOPMENT $2,751.09 PERMIT FEE R000.322.100.00.00 0.00 $1,664.60 PLAN CHECK FEE R000.345.830.00.00 0.00 $1,081.99 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $83.23 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R3139 R000.322.900.04.00 0.00 $83.23 $2,834.32 Date Paid: Wednesday, September 24, 2014 Paid By: SCHOLTEN ROOFING INC Pay Method: CREDIT CARD 680735 Printed: Wednesday, September 24, 2014 8:38 1 of 1 AM CRWSYSTEMS BILE COIN FR-10/FR-504f1REARETARDANT SLIPSHEET ATLAS UPDATED: 05.16.2014 PRODUCT DATA SHEET DESCRIPTION: RECOMMENDED USES: INSTALLATION: STORAGE: WARRANTY AND LIMITATION OF LIABILITY: SLIP SHEET FR-10 and FR-50 fire retardant slipsheets enhance the overall fire performance of many conventional commercial roof systems, including metal roofs. RF-10 and FR-50 are coated -glass fiber mats specifically designed for installation over wood decks or certain combustible insulation. FR-50 incorporates a heavier gloss mat than FR-10 to provide enhanced fire performance. FR-10 and FR-50 are specifically formulated for use over wood decks or polystyrene insulation. The proprietary flame-retardant coating and glass -fiber mat provide protection against flame spread and flame penetration through the roof system. The slipsheet can also act as a barrier between chemically incompatible insulation and roof membranes. In addition, the sheet may be used in multiple layers to achieve certain Class A fire resistance ratings. Atlas Fire Retardant Slipsheets are lightweight, easy to handle and, therefore, quicker to install than thermal barriers or coverboards. The slipsheet should be rolled out, overlapping the side and end of the preceding sheet a minimum of two (2) inches. Consult the membrane manufacturer for specific application recommendations (e.g., slipsheet roll direction perpendicular to membrane roll). Mechanical attachment of the slipsheet is not needed in most applications. The patented coating generally provides enough weight to anchor the sheet until the membrane is installed. Mechanical or adhesive attachment may be necessary under windy conditions. Install only as much slipsheet as can be covered by the end of the day. Factory -applied packaging is intended solely for protection during transit. When stored outdoors or on the job site, the slipsheet rolls should be stocked on pallets at least four inches above ground level and completely covered with a weatherproof covering such as a tarpaulin. Other than the aforementioned representations and descriptions, Atlas Roofing Corporation (hereafter, "Seller") makes no other representations or warranties as to the product sold herein. The Seller disclaims all other warranties, express or implied, including the warranty of merchantability and the warranty of fitness for a particular purpose. The Seller shall not be liable for any incidental or consequential damages including the cost of installation, removal, repair or replacement of this product, insulation and/or roof membrane, etc. The Buyer's remedies shall be limited exclusively to, at Seller's option, the repayment of the purchase price or resupply of product manufactured by Atlas in a quantity equal to that of the nonconforming product. Atlas distributors, agents, salespersons, or other independent representatives have no authority to waive or alter the above limitation of liability and remedies. TYPICAL COMBUSTIBLE DECK/METAL ROOF APPLICATION WOOD DECK METAL ROOFING FR SLIPSH STANDARD SIZES SQUARES PER ROLL COVERAGE W/2" LAP ET TYPICAL COMBUSTIBLE DECK APPLICATION SINGLE -PLY MEMBRANE FR SLIPSHEET - - MEMBRANE -- FASTENER - WOOD DECK EVI WWED FOR YPICAL COMBUSTIBLE DECK APPLICATION E COMPLIANCE APPROVED SEP 2 6 2014 SING MEM EXP EXTRUD City of Tukwila BUILDING DIVISION ROLL SIZE FR 10 10 SQUARES 9.64 SQUARES 48.25"x250' (1,000 sq. ft.) (964 sq. ft.) (1225.55mm x 76.2mm) 961bs. 4.2 SQUARES 4.02 SQUARES 48.00"x105' FR-50 801bs. (420 sq. ft.) (402 sq. ft.) (1219.2mm x 32m) IN -PLY RANE NDEDOR _-- POLYSTYRENE ULATION _ _ - -MEMBRANE FASTENER - --- - FR SLIPSHEET _ - THERMAL BARRIER (GYPSUM BOARD) TENSILE PROPERTIES MACHINE DIRECTION CROSS MACHINE DIRECTION TEST METHOD TAPPI T 1009 om-06 TAPPI T 1009 om-06 FR-10 37 lbs./in. 27 lbs./in. 46 lbs./in. FR-50 64 lbs./in. • Superior protection against flame spread and penetration. • Part of a "Class A" assembly oFeIiliQ)le decks and expanded polystyrene. CITY OF TUKWILA SEP 2 4 2014 PERMIT CENTER • A lightweight and easy -to -install roof system component. • Part of a "Class A" assembly over combustible and noncombustible decks and extruded polystyrene. DI1os1z 770-952-1442 • ATLAS ROOFING CORPORATION • 2000 RIVEREDGE PARKWAY, SUITE 800 • ATLANTA, GA • 30328 • WWW.ATLASROOFING.COM f VELC C ©Pir TECHNICAL INFORMATION SHEET }?,restone BUILDING PRODUCTS UltraPlyTM TPO Membrane Item Description Item Number 1 Roll Various Meets or exceeds ASTM D 6878. Product Information Description: Firestone UltraPlyTM TPO is a flexible Thermoplastic Polyolefin roofing membrane that is produced with polyester weft - inserted reinforcement. UltraPly TPO membrane meets or exceeds all requirements for ASTM D 6878 Specification. This heat weldable TPO membrane is available in 45 mil (1.14 mm) and 60 mil (1.52 mm) thicknesses. This reflective membrane is suitable for a variety of low -slope applications. Method of Application: 1. Substrates must be clean, dry, smooth, and free of sharp edges, fins, loose or foreign materials, oil, grease, and other materials that may damage the membrane. 2. All roughened surfaces that can damage the membrane shall be repaired as specified to offer a smooth substrate. 3. All surface voids greater than 1/4" (6.3 mm) wide shall be properly filled with an acceptable fill material. 4. Firestone UltraPly TPO membrane is installed as continuous roofing or waterproofing layer on the roof. Rolls are overlapped (side laps and end laps) prior to the heat welding of the seam areas. 5. Install the UltraPly TPO Roofing System in accordance with current Firestone UltraPly TPO specifications, details and workmanship requirements. Storage: REVIEWED FOR 'CODE COMPLIANCE • Store away from sources of punctures and physical damage. II.. APPROVED • Assure that structural decking will support the loads incurred by material when stored on rooftop. §Irde k Io q limitations should be specified by the project designer. 6 LUj4 • Store away from ignition sources as membrane will burn when exposed to open flame. Precautions: 1. Refer to Material Safety Data Sheets (MSDS) for safety information. 2. Exercise caution when lifting, moving, transporting, storing or handling membrane rolls to avoid sources o punctures and possible physical damage. 3. Contact your Technical Coordinator at 1-800-428-4511 for specific recommendations regarding chemical or waste product compatibility with Firestone UltraPly TPO Membrane. LEED® Information: Post Consumer Recycled Content: 0% Pre Consumer Recycled Content: 15% Manufacturing Location: Wellford, SC Tuscumbia, AL RECEIVED CITY OF TUKW11-A SEP 2 4 2014 City of Tukwila BUILDING DIVISION MIAMI WDE COUNTY APPROVED ICC-ES ESR-2831 APPROVED CCMC 13348-R PE Itareee E+R'ucts 'Sales: (800) 428-4442 1 Technical (800) 428-4511 1 www.firestonebpco.com S723-RFS-012 TIS # 201 Page 1 of 3 17114-051113.. TECHNICAL INFORMATION SHEET 'Firestone BUILDING PRODUCTS UltraPlyTM TPO Membrane Product Sizes Membrane Thickness: 0.045" (1.14 mm) Membrane Thickness: 0.060" (1.52 mm) Membrane Weight: 0.23 Ib/ft2 (1.1 kg/m2) Membrane Weight: 0.31 Ib/ft2 (1.5 kg/m2) Available Sizes Available Colors Available Sizes Available Colors 5' x 100' (1.5 x 30.5 m) White, Tan, Gray 5' x 100' (1.5 x 30.5 m) White, Tan, Gray 5' x 200' (1.5 x 61 m) White 5' x 200' (1.5 x 61 m) White 6' 2" x 100' (1.9 x 30.5 m) White, Tan, Gray 6' 2" x 100' (1.9 x 30.5 m) White, Tan, Gray 8' x 100' (2.4 x 30.5 m) White, Tan, Gray 8' x 100' (2.4 x 30.5 m) White, Tan, Gray 8' x 200' (2.4 x 61 m) White 8' x 200' (2.4 x 61 m) White 10' x 100' (3.0 x 30.5 m) White, Tan, Gray 10' x 100' (3.0 x 30.5 m) White, Tan, Gray 10' x 200' (3.0 x 61 m) White 10' x 200' (3.0 x 61 m) White 12' 4" x 100' (3.8 x 30.5 m) White, Tan, Gray 12' 4" x 100' (3.8 x 30.5 m) White, Tan, Gray 12'4"x200' (3.8x61 m) White 12'4"x200' (3.8x61 m) White Physical Properties (Meets or exceeds Pro a ASTM D 6878 Specification.) ASTM Standard Performance Typical Performance Typical Performance Minimum 45 mil 60 mil Overall Thickness: D 751 0.039" (1 mm) 0.045" (1.14 mm) ± 10% 0.060" (1.52 mm) ± 10% Coating over Scrim: D 7635 0.015" (0.38 mm) 0.017" (0.43 mm) 0.021" (0.53 mm) Breaking Strength: D 751, Grab Method 220 lbf (979 N) 340 lbf (1,512 N) 390 lbf (1,735 N) Elongation of Reinforcement Break: D 751, Grab Method 15% 25% 25% Tearing Strength: D 751 55 Ibf (245 N) 120 lbf (534 N) 120 lbf (534 N) Brittleness Point: D 2137 -40 °F (-40 °C) Pass Pass Ozone Resistance, No Cracks: D 1149 Pass (No Cracks) Pass Pass Properties After Heat Aging (Retained Values) (ASTM D 573 670 h at 240 °F (116 °C)): Breaking Strength: D 751, Grab Method 90% Minimum > 90% > 90% Elongation at Break: D 751, Grab Method 90% Minimum > 90% > 90% Tearing Strength: D 751 60% Minimum > 60% > 60% Weight of Change: ± 1% Maximum < 1 % < 1 % Linear Dimension Change:D 1204, 6 h at 158 °F (70 °C) ± 1 %Maximum < 1 % < 1 Water Absorption: D 471 ± 3% Maximum < 3% < 3% Physical Properties (Continued) S723-RFS-012 Firestone Building Products ( Sales: (800) 428-4442 I Technical (800) 428-4511 I www.firestonebpco.com TIS # 201 Page 2of3 1/8/2013 TECHNICAL INFORMATION SHEET 'Firestone BUILDING PRODUCTS UltraPlyTM TPO Membrane Property ASTM Standard Performance Typical Performance Typical Performance Minimum 45 mil Membrane 60 mil Membrane Weather Resistance, 80 °C Black Panel, no cracking, crazing when wrapped around a 3" mandrel and inspected at 7X magnification: G 155 10,800 kJ/m2 Minimum > 20,160 kJ/m2 > 20,160 kJ/m2 Puncture Resistance: FTM 101C, Method 2031 265 (1,180) 300 (1,300) Dynamic Puncture Resistance MD: D 5635 Pass (20 J) Pass (40 J) Dynamic Puncture Resistance CD: D 5635 Pass (35 J) Pass (50 J) Static Puncture Resistance: D 5602 Pass (25 kg) Pass (25 kg) Radiative Properties Cool Roof Rating Council (CRRC): Initial / 3 yr White Tan Gray. Solar Reflectance 0.79 / 0.68 0.61 / 0.55 0.34 / Pending Thermal Emittance 0.85 / 0.83 0.81 / 0.84 0.89 / Pending Solar Reflectance Index (SRI) 98 / 81 71 / 63 37 / Pending Rated Product ID 0008 Licensed Manufacturer ID 0608 Classification Production Line ENERGY STAR®: Initial / 3 yr White Tan Solar Reflectance 0.79 / 0.78* 0.60 / 0.54 Thermal Emittance 0.85 0.81 White membrane sample cleaned prior to age test. LEED® White Tan Gray Solar Reflectance — ASTM E 903 0.81 0.63 0.37 Thermal Emittance — ASTM E 408 0.95 0.95 0.95 Solar Reflectance Index (SRI) — ASTM E 1980 102 77 43 'Firestone CR C C,CN. un>tc<;arwi. CHARTER MEMBER ENERGY STAR is only valid in the United States Please contact your Firestone Roof Systems Advisor at 1-800-428-4511 for further information. This sheet is meant to highlight Firestone products and specifications and is subject to change without notice. Firestone takes responsibility for fumishing quality materials which meet published Firestone product specifications. Neither Firestone nor its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or resultant damages. Consult a competent structural engineer prior to installation if the structural soundness or structural ability to properly support a planned installation is in question. No Firestone representative is authorized to vary this disclaimer. 5723-RFS-012 Firestone Building Products 1 Sales: (800) 428-4442 I Technical (800) 428-4511 I www.firestonebpco.com TIS # 201 Page 3 of 3 1/8/2013 City of Tukwila Department of Community Development 2/2/2015 BARRY BERENDSEN 7157 GUIDE MERIDIAN LYNDEN, WA 98264-9499 RE: Permit No. D14-0312 ANDOVER PARK BLDG 1 1206-1210 ANDOVER PARK E Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 3/28/2015. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 3/28/2015, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D14-0312 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 ?ERM1T COORD COPY r PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0312 PROJECT NAME: ANDOVER PARK BLDG 1 DATE: 09/24/2014 SITE ADDRESS: 1206-1210 ANDOVER PK E X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: kT Aug' Building Division Public Works n Fire Prevention Structural AO- ct-g--ti-f 11 Planning Division Permit Coordinator ❑ PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 09/25/14 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) DUE DATE: 10/23/14 Approved with Conditions Denied ❑ (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 SCHOLTEN ROOFING INC Page 1 of 3 Wash ngtOn State Uepat to ent OI Labor & industries SCHOLTEN ROOFING INC Owner or tradesperson BERENDSEN, BARRY Principals BERENDSEN, BARRY UNREIN, RUSSELL E, PRESIDENT BERENDSEN, HENRY JR, VICE PRESIDENT ESHUIS, GALEN (End: 04/04/2013) SCHOLTEN, JACK (End: 04/04/2013) ESHUIS, MICHAEL G, VICE PRESIDENT (End: 04/04/2013) PARRIERA, JEREMY W, VICE PRESIDENT (End: 04/04/2013) Doing business as SCHOLTEN ROOFING INC WA UBI No. 600 087 488 7157 GUIDE MERIDIAN ROAD LYNDEN, WA98264-9499 360-398-8484 WHATCOM County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. SCHOLI*211 K5 Effective — expiration 05/25/1979— 05/08/2015 Bond WESTERN SURETY CO Bond account no. 9312917 Received by L&I 07/23/2004 Active. Meets current requirements. $12,000.00 Effective date 08/28/2004 Expiration date Until Canceled https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600087488&LIC=SCHOLI*211K5&SAW= 09/29/2014