Loading...
HomeMy WebLinkAboutPermit D14-0313 - LULULEMON RACKS - STORAGE RACKSLULULEMON RACKS 21 SOUTHCENTER MALL D14-0313 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No: 9202470130 Permit Number: D14-0313 Address: 21 SOUTHCENTER MALL Issue Date: 10/14/2014 Permit Expires On: 4/12/2015 Project Name: LULULEMON RACKS Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD, CA, 92013 Contact Person: Name: MELANI DANNENBERG Phone: (310) 263-3587 Address: 20521 EARL ST , TORRANCE, CA, 90503 Contractor: Name: R MILLER INC Phone: (425) 775-3822 Address: 1832198 AVE NE, STE 1, BOTHELL, WA, 98011 License No: RMILLMI871NH Expiration Date: 8/8/2015 Lender: Name: Address: DESCRIPTION OF WORK: INSTALLATION OF BACK OF HOUSE PIPP MOBILE STORAGE SYSTEM SHELVING Project Valuation: $10,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: IIB Fees Collected: $491.22 Occupancy per IBC: M Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2014 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: 1'' 0 1,(1 I hearby certify that I have read and exami ed this permit and know the same to be true and correct. All provisions of law and ordinances go ernin; this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit anjagree p the cAnditions attached to this permit. Signature: Print Name: vlV L�l 1 c� C�C�'' Date: I —„ I( This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: Clearance between ignition sources, such as light fixtures, heaters and flame -producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 13: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.3.1) 14: Flue spaces shall be provided in accordance with International Fire Code Table 3208.3. Required flue spaces shall be maintained. 9: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 8: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 18: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 10: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 15: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 16: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 4046 SI-EPDXY/EXP CONC CITY OF TUKr...:A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Building Permit No. Project No. Date Application Accepted: Date Application Expires: plq- ()11-t— com ) tt, (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 1 Site Address: 21 Southcenter Mall Tenant Name: Lululemon Athletica PROPERTY OWNER Name: Westfield Property Tax Department Address: PO Box 130940 City: Carlsbad State: CA Zip: 92013 CONTACT PERSON — person receiving all project communication Name: Melani Dannenberg . Address: 20521 Earl St. City: Torrance State: CA Zip: 90503 Phone: (310) 263-3587 Fax: Email: GENERAL CONTRACTOR INFORMATION Company Name: R. Miller, Inc. Address: 18321 98th Avenue NE, Suite 1 City: Bothell State: WA Zip: 98011 Phone: (425) 775-3822 Fax: (425) 977-4898 Contr Reg No.: RMILLMI871NH Exp Date: 08/08/2015 Tukwila Business License No.: bus — 0ap' i, 'l -o'D Suite Number: 748 Floor: New Tenant: VI Yes ❑..No ARCHITECT OF RECORD Company Name: /k"-. E /1 cm 5 Architect Name:/ `'� ` L ail • 0A4/LG/I b Cr.g..--, Address'ZC+SL E 4. City r r O.A C.C.,State: C zip: 616567 Phone:3,b.Z, 6 3.3yg7ax: Email: ENGINEER OF RECORD Company Name: Eclipse Engineering Engineer Name: Rolf Armstrong Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: H:\Applications\Forms-Applications On Line12011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 1 of 4 BUILDING PERMIT INFORMATIO'. E06-431-3670 Valuation of Project (contractor's bid price): $ I K Describe the scope of work (please provide detailed information): Installation of back of house Pipp Mobile Storage System shelving. Will there be new rack storage? m Yes Existing Building Valuation: $ 111.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC Vt Floor 3/ / 77 2nd Floor 3rd Floor Floors thni Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Floor area of accessory dwelling: O Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fortes-Applications On Line\2011 Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFO1 ATION — 206-433-0179 Scope of Work (please provide detailed information): Ca11 before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate ❑ .. Highline ❑...Valley View 0 .. Renton 0...Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) 0 ...Bond ❑ .. Insurance 0 .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer 0 ...Cap or Remove Utilities 0 ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑...Traffic Impact Analysis ❑ ... Hold Harmless — (SAO) ❑ ... Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use —Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage El .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line ❑ .. Grease Interceptor El .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding 0 ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size WO # 0 ...Deduct Water Meter Size ❑ ...Sewer Main Extension Public 0 Private 0 ❑ ...Water Main Extension Public 0 Private 0 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0 ...Water 0 ...Sewer 0 ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-1 Ldocx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER O AUTHORIZED AGENT: Signature: Print Name: Date: q• Z 3.r / 7 Day Telephone: 7-66 . 3 ta5 6/ Mailing Address: 1 S'3 Z I 7 v'- � l� � /'' z I B OA-1 W q.a ?> City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-I I.docx Revised: August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT I QUANTITY PermitTRAK PAID $491.22 D14-0313 Address: 21 SOUTHCENTER MALL Apn: 9202470130 $491.22 DEVELOPMENT $476.90 PERMIT FEE R000.322.100.00.00 0.00 $286.30 PLAN CHECK FEE R000.345.830.00.00 0.00 $186.10 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $14.32 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R3155 R000.322.900.04.00 0.00 $14.32 $491.22 Date Paid: Thursday, September 25, 2014 Paid By: R. MILLER INC. Pay Method: CHECK 12635 Printed: Thursday, September 25, 2014 9:07 AM 1 of 1 CRWSYSTEMS INSPECTION NO. Retain a copy with permit U 17-033 PERMIT NO. INSPECTION RECORD \ II CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-360 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection- " Address eM SUANCVAA4(4— Mg. /I Date Date Called: Special Instruchons: Cii(- 5 ivM. Date Wanted: a.m. Requeler, Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMME 17Lq cff Inspector: _.....----- DateLf 7 -iS REINSPE ON FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /VCR / 5 > V- 0/sue /'/5 -- !9-t ) .l J, I `._ ,n / /N ? I �r PERMIT NUMBERS D) C(— 0 313 CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: ` , ___(...4 / t.„,, ,r a., t-0--7.- - \ Type f Inspection: 1/4 Z---7P/e-yz_ / ,. . ,_ Address: Suite #: /� Contact Person: / / Special Instructions: Phone No.: Approved per applicable codes. /\ Corrections required prior to approval. COM{ M//wENTS: /}�f ,,/c//'' \ // 7;;:;. p//€ A. E '--"�/ l Y( — f L r , [�f `2`11,77 a� ?f % /� f — f 77 JJ P - W-'.% — ! `\ 1L 0 t4- r Je /7/ / +J /*s! 1l - //4 CcA 41 4 -•., - P c FCC / u' "% Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: -- ! � 4 Date: ,/ U % 2-4 y Hrs.: / 1' $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Address: Company Name: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 OTTO ROSENAU & ASSOCIATES, INC. October 23, 2014 California Special Inspections 44444 Buena Vista Way Lancaster, CA 93536 Geotechnical Engineering, Construction Inspection & Materials Testing 6747 M. L. King Way South, Seattle, Washington 98118-3216 USA Tel: (206) 725-4600 • Toll Free: (888) OTTO-4-US • Fax: (206) 723-2221 WBE W2F5913684 • WABO Registered Agency • Website: www.ottorosenau.com Project: Lulu Lemon Site Address: 21 Southcenter Mall, Tukwila ORA Job No.: 14-0708 FINAL REPORT \DI'-I0313 We herewith certify that we have completed the following special inspections. To the best of our knowledge, the work inspected was in conformance with the approved plans and specifications and the applicable workmanship provision of the building code. Our knowledge is limited to our reports. All typewritten reports have been sent to your office or are enclosed. All reports appear to be complete. This report should not be considered as a warranty for conditions and/or details of the building. Item(s) inspected: 1. Expansion anchor bolt installation Sincerely, OTTO ROSENAU & ASSOCIATES, INC. Susan Rosenau-Moser Vice President RECEIVED CITY OF TUKWILA MAR 2 3 2015 PERMIT CENTER OTTO ROSENAU & ASSOCIATES, INC. Geotechnical Engineering, Construction Inspection & Materials Testing PROPRIETARY ANCHOR MECHANICAL INSPECTION REPORT Job Number: 14-0708 Project: Lulu Lemon Store - Tukwila Address: 21 Southcenter Mall, Tukwila Inspector: Dwayne Helgeson Report Number: 242272 Permit Number: D14-0313 Client: California Special Inspections Address: 44444 Buena Vista Way, Lancaster Date: 10/15/14 Description/Location: Inspected the installation and torqueing of 3/8" KB-TZ Kwik Bolts at base of shelving system in stock room. Intended Use: Shelf anchor bolts Building Code & Year: 2012 IBC Size & Quantity: 3/8" (18 total) Anchor Style: // Expansion 0 Screw • Sleeve • Drop In Anchor ESR Number: 1917 Anchor Manufacturer: Hilti Anchor Type: KB-TZ Hole Diameter: 3/8" Hole Depth: 2 Yz' Required Embedment: 2''A" Anchor Length: 3" Concrete Thickness: N/A Concrete Strength: N/A Base Material: ►/ Normal Weight Concrete ■ Light Weight Concrete ■ CMU ■ Brick • Composite Deck Hole Cleaning: Compressed Air • Hand Pump ■ Other: ORA Torque Wrench ID: 5999 Torque: 40 ft-Ibs Drill Bit (ANSI B212.15): ►:/ Yes • No Weather: Indoors Ambient Temperature: 70°F Comments Work inspected was found to be done in accordance with the approved project documents. Reference Standard(s) Used: Copies to: X Client Engineer Owner Contractor Architect Building Dept. Others Technical Responsibility: Conforms X Does Not Conform RECEIVED CITY OF TUKWILA MAR 2 3 2015 PERMIT CENTER Jeff Rabe, Project Manager This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report, except in full, without written permission from our firm is strictly prohibited. Page 1 of 1 6747 M.L. King Way S., Seattle, Washington 98118 - Phone (206) 725-4600 or 1-888-OTTO-4-US - Fax (206) 723-2221 Form No.: ADMIN-87-02(Rev 05/13) ECLI PSE ECLIPSE -ENGINEERING . C O M ENGINEERING ..,. doorliiat May 9L.* Structural Calculations Steel Storage Racks By Pipp Mobile Storage Systems, Inc. PIPP PO #116788 SO #346584 Lululemon #10503 SEP 1 Westfield Southcenter Mall 21 Southcenter Mall - Space #748 Tukwila, Washington 98188 Prepared For: Pipp Mobile Storage Systems, Inc. 2966 Wilson Drive NW Walker, MI 49544 REVIEWED FOR CODE COMPCIANCE APPROVED OCT 09 2014 BUILDINGCity DIVISION RECEIVED CITY OF TUKWILA SEP 2 5 2014 PERMIT CENTER Please note: The calculations contained within justify the seismic resistance of the shelving racks, the fixed and mobile base supports, and the connection to the existing partition walls for both lateral and overturning forces as required by the 2012 International Building Code. These storage racks are not accessible to the general public. P114 o,t'3 MISSOULA WHITEFISH U3 West Mail. Stile B. M ssoula, MT 59802 Phone: (406) 721-5733 • Fax (406) 721.4988 1005 Baker Ave, Suite E, Whdefah. MT 59937 Phone: (406) 862-3715 • Fax 406862.3718 SPOKANE BEND 421 West Riverside Ave., Suite 421 Spokane, WA 99201 Phone: (509) 921.7731 • Fax (509) 921-5704 376SWBu6Dmre,Suite 8,Bend, 0R 97702 Phone: (541) 3899659 • Fax (541) 312.8708 ECLI PSE ENGINEERING LULULEMON #10503 9/10/2014 TUKWILA, WA Rolf Armstrong, PE Pipp Mobile STEEL STORAGE RACK DESIGN 2012 IBC & 2013 CBC - 2208 & A5CE 7-10 - 15.5.3 Design Vertical Steel Posts at Each Corner : plf:= Ib.ft 1 Shelving Dimensions: psf:= Ib•ft 2 Total Height of Shelving Unit- ht:= 9.00•ft pcf:= Ib.ft3 Width of Shelving Unit - w := 4.00.ft ksi := 1000.113. in 2 Depth of Shelving Unit - d := 1.25• ft kips := 1000• Ib Number of Shelves - N := 8 Vertical Shelf Spacing - S := 15.43. in Shelving Loads: Maximum Live Load on each shelf is 75 Ibs: Weight per shelf - Wt1 := 75• lb Load in psf - Wti LL; := w•d Design Live Load on Shelf- LL := LLB Dead Load on Shelf - DL := 2.50• psf Section Properties of Double Rivet 'L' Post : Wti = 75 lb LLi = 15• psf LL = 15. psf Modulus of Elasticity of Steel - E := 29000. ksi b := 1.5 in h:= 1.5•in Steel Yield Stress - Fy := 33• ksi ry := 0.47 in Section Modulus in x and y - S, := 0.04•in3 := 0.47. in Moment of Inertia in x and y - IX := 0.06. in4 t := 0.075. in Full Cross Sectional Area - Ap := 0.22• in2 h,:= 1.42 in bc:= 1.42.in Length of Unbraced Post - LX := S = 15.43• in Ly:= S = 15.43• in Lt:= S = 15.43• in Effective Length Factor- KX:= 1.0 Ky:= 1.0 Kt:= 1.0 Section Properties Continued: Density of Steel - psteel := 490. pcf Weight of Post - Wp := psteel. Ap. ht Wp = 6.74. lb Vertical DL on Post - Pd := DL• w• .25d• N + Wp Pd = 31.741b Vertical LL on Post- Pi := LL• w• .25. d• N Pi = 1501b Total Vertical Load on Post - Pp := Pd + Pi Pp = 181.74• Ib 1 ECLI PSE ENGINEERING LULULEMON #10503 9/10/2014 TUKWILA, WA Rolf Armstrong, PE Floor Load Calculations : Weight of Mobile Carriage: We := 0• lb Total Load on Each Unit: W:= 4. Pp + We W = 726.95 lb Area of Each Shelf Unit: Au := w•(d + 9in) Au = 8ft2 Floor Load under Shelf: PSF := W Au NOTE: SHELVING LIVE LOAD IS CONSISTENT WITH 100 psf REQ'D FOR RETAIL FLOOR LOADING PSF = 91• psf Find the Seismic Load using Full Design Live Load : ASCE-7 Seismic Design Procedure: Importance Factor- IE:= 1.0 Determine Ss and Si from maps - Ss := 1.458 51:= 0.544 Determine the Site Class - Class D Determine Fa and F, - Fa := 1.000 F,:= 1.500 Determine SMs and SM1 _ SMs := Fa: Ss SM1 := Fv. S1 SMs = 1.458 SM1= 0.816 Determine Sinand SDI _ SDS 3 • SMs SDI 3 • SM1 SDS = 0.972 SDI = 0.544 Structural System - Section 15.5.3 ASCE-7: 4. Steel Storage Racks Total Vertical LL Load on Shelf - Total Vertical DL Load on Shelf - R:= 4.0 Rp:= R WI:= LL•w•d S2o:= 2 ap := 2.5 Wp Wd := DL w• d + 4• N Seismic Analysis Procedure per ASCE-7 Section 13.3.1: Average Roof Height - hr := 20.0• ft Height of Rack Attachment- z:= 0•ft Seismic Base Shear Factor - Shear Factor Boundaries - 0.4•ap•SDs Vt:= 1 + 2• Rp hr) Ip Cd:= 3.5 Ip := 1.0 WI = 751b Wd = 15.871b (0-0" For Ground floor) Vt = 0.243 Vtmin 0.3• SDS• Ip Vtmin = 0.292 Vtmax := 1.6• SDS. Ip Vtmax = 1.555 Vt:= if(Vt > Vtmax, Vtmax, Vt) Vt:= if(Vt < Vtmin, Vtmin, Vt) Vt = 0.292 2 :ECLIPSE LULULEMON #10503 9110/2014 ENGINEERING TUKWILA,WA Seismic Loads Continued : For ASD, Shear may be reduced - Seismic DL Base Shear - DL Force per Shelf : Seismic LL Base Shear - LL Force per Shelf : 0.67 * LL Force per Shelf: v v := t = 0.208 p 1.4 Vtd := Vp• Wd• N = 26.441b Fd:=Vp•Wd=3.311b Vt1:= Vp• Wl• N = 124.971b F1:= Vp•W1= 15.621b F1.67:= 0.67.Vp•Wl = 10.471b Force Distribution per ASCE-7 Section 15.5.3.3: Operating Weight is one of Two Loading Conditions : Condition #1: Each Shelf Loaded to 67% of Live Weight Cumulative Heights of Shelves - H1:= 0.0•S+ 1.0.S+ 2.0.S+ 3.0•S+ 4.0.S+ 5.0•S+ 6.0•S+ 7.0•S Rolf Armstrong, PE H2:= 0 H:= H1 + H2 H = 36ft Total Moment at Shelf Base - Mt:= H• Wd + H. 0.67• W1 Mt = 2380.5 ft. lb Vertical Distribution Factors for Each Shelf - Total Base Shear- Vtotal := Vtd + 0.67• Nit' Vtotal = 110.171b Wd• 0.0• S + WI. 0.67.0.0• S Wd• 1.0. S + Wl• 0.67.1.0. S C1:= — 0 C2:= — 0.036 Mt Mt c3.- Fl:= Cr(Vtotal) = 0 Wd• 2.0• S + Wl• 0.67. 2.0. S Mt F3 C3' (Vtotal) = 7.871b = 0.071 Wd•4.0•S+ Wl•0.67.4.0.S C5.— = 0.143 Mt F5 C5'(Vtotal/ = 15.741b Wd•6.0.S+ Wl•0.67.6.0.S C7:= — 0.214 Mt F7:= C7.(Vtotal) = 23.611b Cl+C2+C3+C4+C5+C6+C7+C6= 1 C4:- F2:= C2.(Vtotal) = 3.931b Wd• 3.0• S + Wl• 0.67.3.0. S Mt F4:= C4'(Vtotal) = 11.81b — 0.107 Wd• 5.0. S + Wl• 0.67.5.0. S C6:— = 0.179 Mt F6:= C6' (Vtotal) = 19.671b Wd•7.0.S + Wl•0.67.7.0•S C8:= — 0.25 Mt F8:= C8.(Vtotal) = 27.541b 3 ECLI PSE ENGINEERING LULULEMON #10503 9/10/2014 TUKWILA, WA Rolf Armstrong, PE Force Distribution Continued : Condition #2: Top Shelf Only Loaded to 100% of Live Weight Total Moment at Base of Shelf - Total Base Shear- Wd• 0.0• S + 0• Wl• 0.0• S Cla:= — 0 Mta Mta Fla := C1a'(Vtotal2) = 0 Ftsa = Ctsa' (Vtotal2) = 42.06Ib Condition #1 Controls for Total Base Shear By Inspection, Force Distribution for intermediate shelves without LL are negligible. Moment calculation for each column is based on total seismic base shear. Column at center of rack is the worst case for this shelving rack system. Mta:= (N — 1)•S.Wd + (N — 1)•S•Wl = 818ft•Ib Vtotal2 Vtd + Fl Vtotal2 = 42.06Ib Wd•(N — 1)•S + W1•(N — 1)•S Ctsa :_ — 1 Column Design in Short Direction : Ms 4' 2'(Vtotal) = 17.71ft• lb Bending Stress on Column - fbx := M. SX 1 = 5.31. ksi Allowable Bending Stress - Fb := 0.6. Fy = 19.8. ksi Bending at the Base of Each Column is Adequate Deflection of Shelving Bays -worst case is at the bottom bay 3 :_ (Vtd + Vtl� S — 0.0266• in S = 579.2081 12• E. I, 0 At:= 0 (N — 1) = 0.1865•in O:= 0.05.ht= 5.4•in if(Ot < Da, "Deflection is Adequate" , "No Good") = "Deflection is Adequate" Moment at Rivet Connection: Shear on each rivet - 2 dr:= 0.25•in Vr:= Ms — 141.661b Ar:= dr — 0.0491•in2 1.5• in 4 Vr Stress on Rivet - f„ :_ = 2.89. ksi Ar Ultimate Stress on Rivet (SAE C1006 Steel) - Fur:= 47.9ksi Omega Factor (ASD) - S2r := 2.0 Allowable Stress on Rivet - Fvr:= 0.4• Fur 12r 1 = 9.58• ksi f Ratio of Allowable / Ultimate Stress - - = 0.3012 Fvr RIVET CONNECTION IS ADEQUATE FOR MOMENT CONNECTION FROM BEAM TO POST 4 ECLIPSE ENGINEERING Seismic Uplift on Shelves : Seismic Vertical Component: Vertical Dead Load of Shelf: LULULEMON #10503 9/10/2014 TUKWILA, WA Rolf Armstrong, PE Ev:= 0.2.Sos•(DL + LL)•w•d E„= 17.01lb D:= (DL + LL)•w•d D = 87.51b Note: since the shelf LL is used to generate the seismic uplift force, it may also be used to calculate the net uplift load. For an empty shelf, only the DL would be used, but the ratio of seismic uplift will be the same. Net Uplift Load on Shelf: Fu:=E„-0.6.D F„=-35.491b Note: This uplift Toad is for the full shelf. Each shelf will be connected at each comer. Number of Shelf Connections: Uplift Force per Corner: Nc:= 4 F„ Fuc:= N c Fuc = —8.8725 lb NOTE: Since the uplift force is negative, a mechanical connection is not required. 5 ECLIPSE ENGINEERING LULULEMON #10503 9110/2014 TUKWILA, WA Rolf Armstrong, PE Find Allowable Axial Load for Column : Allowable Buckling Stresses- 71.2 E — 265.56• ksi Kx Lx 12 r, ) Distance from Shear Center to CL of Web via X-axis t hc2 bc2 4• Ix 0ex : _ 0ex.x = 265.56 ksi ec = 1.2706• in Distance From CL Web to Centroid - xc := 0.649• in — 0.5• t x. = 0.6115• in Distance From Shear Center xo := xc + ec xo = 1.8821. in to Centroid - Polar Radius of Gyration - ro ]rx2 ry2 + xo2 ro = 1.996• in Torsion Constant - J:= 3 • (2• b• t3 + h• t3) J = 0.00063. in4 Warping Constant- CW:= t•b3•h2 2•h•t)C,= 0.0339in6 12 (3.b.t+ 6.b•t+ h•t ) Shear Modulus - G := 11300. ksi 1 0t _ Ap • ro (3 := 1- 7C2• EC 1 GJ+ Kr Lt) 2 IJ Fet := 21R [(ex+t)_I(ex+ (It) — 4• R. c'ex• Q] Elastic Flexural Buckling Stress - Allowable Compressive Stress - Factor of Safety for Axial Comp. - Qt = 54.6557. ksi 3 = 0.1109 Fet = 46.0616• ksi Fe := if(Fet < 6exFet, (rex) Fe = 46.0616• ksi Fn := if Fe > FY Fy• 1— Fy 1, F,1 Fe = 27.0894• ksi 2 4•Fe) J Sto := 1.92 6 �k - EC LI FS E LULULEMON #10503 9/1012014 ENGINEERING TUKWILA, WA Rolf Armstrong, PE Find Effective Area - Determine the Effective Width of Flange - Flat width of Flange - wf:= b — 0.5• t Flange Plate Buckling Coefficient - kf:= 0.43 Flange Slenderness Factor Xf:= 1.052 w f F n V"f t E Pr= (1- 0.22) 1 Xf J Xf Effective Flange Width - be := if(Xf > 0.673, pr Wf, wf) be = 1.1777• in Determine Effective Width of Web - FlatwidthofWeb- ww:= h — t w, = 1.425. in Web Plate Buckling Coefficient - kw := 0.43 wf = .1.4625• in Web Slenderness Factor - Effective Web Width - Effective Column Area - Nominal Column Capacity - Allowable Column Capacity - Check Combined Stresses - 72. E. Ix 'Dux:_ (Kx. Lx)2 Pcr Pax Magnification Factor - Combined Stress: Xf = 0.9561 Pf = 0.8052 Xw = 1.052 ww Fn \w = 0.9316 V "w t Pw •_ C1 _ 0.221 1 Pw = 0.8199 %w ) >�w he := if(xw > 0.673, pw.ww, ww) he = 1.1684• in A, := t•(he+ be) Ae = 0.176•in2 Pri := Ae. Fri Pn = 47661b Pn Pa:= Pa = 24831b Pm( = 7.21 x 1041b Pcr = 72130.2 lb a:= 1 - iioPp) Pcr ) Pp Cm fbx + = 0.302 Pa Fb•a a = 0.995 Cm := 0.85 MUST BE LESS THAN 1.0 Final Design: 'L' POSTS WITH BEAM BRACKET ARE ADEQUATE FOR REQD COMBINED AXIAL AND BENDING LOADS NOTE: Pp is the total vertical load on post, not 67% live load, so the design is conservative 7 1,•ECLIPSE ENGINEERING STEEL BASE Tension (Uplift) Force at Corner: Thickness of Angle: Width of Angle Leg: Distance out to Tension Design Moment on Angle: Allowable Bending Stress: Ultimate Tensile Strength of Clip: Effective Net Area of the Clip: LULULEMON #10503 9/10/2014 TUKWILA, WA Rolf Armstrong, PE CLIP ANGLE DESIGN - A1018 PLATE STEEL Force: T := 75• Ib to := 0.075• in ba := 1.25• in L:= 0.75.in M:= T•L= 4.6875ft•Ib Fb := 0.90. Fyp = 32.4. ksi Fup := 65• ksi Yield Stress of Angle Steel: 14 ga Foot Plate Fyp := 36• ksi Length of Angle Section: La := 1.375. in Section Modulus of Angle Leg: Bending Stress on Angle: Ratio of Allowable Loads: Gross Area of the Clip: Aec := Age — Eta. (0.375• in)] = 0.0656. in2 ba• ta2 Za:= 4 — 0.0018•in3 fb := Z = 32• ksi a fb — = 0.988 Fb Agc:= ba•ta = 0.0938.in2 Limiting Tensile Strength of Clip: Tcmax min[(0.90• Fyp• Age) , (0.75. Fup• AeC)1 = 3037.5 Ib 14 GA. ANGLE CLIP WILL DEFORM PRIOR TO ANCHOR PULLING OUT OF CONCRETE, BUT NOT WILL NOT TEAR COMPLETELY THROUGH, THEREFORE CLIPS ARE ADEQUATE. BEARING STRENGTH OF SCREW CONNECTIONS - AISC 37 Specified Yield Stress of Post - Width of Screw - 14 GA Thickness - Projected Bearing Area - Single Screw Fys:= 36ksi wss:= 0.25in tss:= 0.075in Abs wss• tss = 0.0188. in2 Nominal Bearing Strength - Rns := 1.8• Fys•Abs = 1215 Ib Omega for Bearing (ASD) S Phi for Bearing (LRFD) - Allowable Bearing Strength - Ras Rns. 'ks = 911.25 Ib Double Screw Fyd := 36ksi wsd := 0.50in tsd := 0.075in Abd:= wsd•tsd = 0.0375•in2 Rnd := 1.8• Fyd• Abd = 24301b cis := 2.0 (l)s:= 0.75 Rad Rnd• (1)s = 1822.5 Ib SCREW CONNECTION CAPACITIES (1/4"4 SCREW IN 14 GA STEEL): Converted to LRFD for comparison to 'Hilti' A.B. Single Screw Double Screw Allowable Tension - Tss Qs. (1)s. 328Ib Tsd fts- �s 6561b Ref Attached 'Scafco' Allowable Shear- Vss [s.43.s.866Ib Vsd �s.cbs• 1732Ib Table forV & T Values The allowable shear values for (1) 114" dia. screw exceeds the allowable bearing strength of the connection. Therefore, bearing strength govems for screw connection capacity. MUST BE LESS THAN 1.00 8 'tt.„5 ECLI PSE ENGINEERING LULULEMON #10503 9/10/2014 TUKWILA, WA Rolf Armstrong, PE BOLT CONNECTION CAPACITIES (3/8" DIA. x 2" HILTI KB-TZ): Single Anchor Double Anchor Ref Attached 'HILTI' PROFIS calcs Tas:= 1051•Ib Tad:= 1993.lb for t/&TValues Allowable Tension Force - Allowable Shear Force - Vas := 1466• Ib Vad := 1938• Ib DETERMINE ALLOWABLE TENSION/SHEAR FORCES FOR CONNECTION: Single Anchor Double Anchor Allowable Tension Force- Tas:= min(Tas, Vss, Ras) = 911.25 Ib Tad := min(Tad, Vsd, Rad) = 1822.5 Ib Allowable Shear Force - Vas := min(Vas, Tss) = 4921b Vad:= min(Vad, Tsd) = 9841b USE: HILTI KB-TZ ANCHOR (or equivalent) - 318" x 2" long anchor installed per the requirements of Hilti to fasten fixed shelving units to existing concerete slab. Use 1/4" dia. screw to fasten base to 14 GA shelf member. 9 ECLI PSE ENGINEERING LULULEMON #10503 9/10/2014 TUKWILA, WA Rolf Armstrong, PE STEEL STORAGE RACK DESIGN - cont'd Find Overturning Forces : Total Height of Shelving Unit- Ht:= ht = 9 ft Width of Shelving Unit- w = 4ft Depth of Shelving Unit - d = 1.25ft WORST CASE Number of Shelves - N = 8 Vertical Shelf Spacing - S = 15.43. in Height to Top Shelf Center of G - htop:= Ht htop = 9ft Height to Shelf Center of G - ho:= (N + 1) S he = 5.7862.ft 2 From Vertical Distribution of Seismic Force previously calculated - Controlling Load Cases - Weight of Rack and 67% of LL - W := (Wd + 0.67. Wi)• N W = 528.95 Ib Seismic Rack and 67% of LL - V := Vtd + 0.67• V 1 V = 110.17 Ib Ma := Fl• 0.0• S + F2.1.0• S + F3.2.0• S + F4 3.0• S + F5.4.0• S + Fs• 5.0• S + F7• 6.0• S + F8.7.0• S Mb:= 0 0verturring Rack and 67% of LL - M := Ma + Mb = 708.32 ft. Ib Weight of Rack and 100% Top Shelf - Wa := Wd• N + Wi Wa = 201.95 Ib Seismic Rack and 100% Top Shelf - Va := Vtd + Fi Va = 42.06 Ib 0verturring Rack and 100% Top Shelf Ma := Vtd" ho + Fi htop Ma = 293.59 ft• Ib Controlling Weight - Wo:= if(W > Wa, W, Wa) Wo = 528.95 Ib Controlling Shear- Vo:= if(V > Va, V, Va) Vo = 110.171b Controlling Moment - Mat := if(M > Ma, M, Ma) Mot = 708.32 ft. Ib Wo Tension Force on Column Anchor- T := Mot — 0.60.— T = 407.971b d 2 Tmax:= if(T < 0• Ib, 0• Ib, T) Tmax = 407.971b V Shear Force on Column Anchor - Vmax:= o Vmax = 55.09 Ib 2 per side of shelving unit USE: HILTI KWIK BOLT TZ ANCHOR (or equivalent) - USE 3/8" 4 x 2" embed installed per the requirements of Hilti Combined Loading (Single ' Tmax 1 ' Vmax 1� Anchor / Screw) - Combined Loading (Double Anchor / Screw) - + = 0.16 <1.00 OKAY 2.0.7•Tas J 2.0.7•Vas ) Tmax + Vmax = 0.16 < 1.00 OKAY 1.0.7•Tad ) t1.0.7•Vad 5 C 3 10 ECLIPSE ENGINEERING LULULEMON #10503 9/10/2014 Connection from Steel Racks to Wall TUKWILA, WA Rolf Armstrong, PE Seismic Analysis Procedure per ASCE-7 Section 13.3.1: Average Roof Height- hr = 20ft Height of Rack Attachments - zb := z + ht zb = 9ft At Top for fixed racks connected to walls Seismic Base Shear Factor- Vt:= 0.4 ap Sos 1 + 2. zb Vt = 0.462 Rp hr) Ip Shear Factor Boundaries - Vtmin := 0.3• Sps• Ip Vtmin = 0.292 Vtmax : = 1.6• Sps• 1p Vtmax = 1.555 Vt:= if(Vt > Vtmax, Vtmax, Vt) Vt:= if(Vt < Vtmin, Vtmin, Vt) Vt = 0.462 Seismic Coefficient - Vt = 0.462 Number of Shelves - N = 8 Weight per Shelf - Wti = 751b Total Weight on Rack - WT := 0.667.4. Pp WT = 484.88 lb 0.7.Vt. WT Seismic Force at top and bottom - Tv := Tv = 78.35 lb 2 Connection at Top: Standard Stud Spacing - Sstud 16. in Width of Rack - w = 4ft Number of Connection Points - Nc:= max 2, floor w 111 N 3 c= on each rack Sttud JJJ Force on each connection point - Capacity per inch of embedment - TV Fe := N— Fc = 26.121b Ws := 135• lb— in F Required Embedment- ds:= c Ws For Steel Studs: Pullout Capacity in 20 ga studs - per Scafco ds = 0.193• in T20 := 84• lb For #10 Screw- per Scafco MIN #10 SCREW ATTACHED TO EXISTING WALL STUD IS ADEQUATE TO RESIST SEISMIC FORCES ON SHELVING UNITS. EXPANSION BOLT IS ADEQUATE BY INSPECTION AT THE BASE 11 ;ECLIPSE ENGINEERING LULULEMON #10503 9/1012014 TUKWILA, WA Rolf Armstrong, PE Pipp Mobile STEEL STORAGE RACK DESIGN 2012 IBC & 2013 CBC - 2208 & ASCE 7-10 - 15.5.3 Design Vertical Steel Posts at Each Corner : plf:= lb- ft 1 Shelving Dimensions: psf:= lb. ft— 2 Total Height of Shelving Unit - ht := 9.00• ft pcf := 11341 3 Width of Shelving Unit - w := 2.50• ft ksi := 1000• Ib• in 2 Depth of Shelving Unit - d := 1.50.ft kips := 1000• Ib Number of Shelves - N := 4 Vertical Shelf Spacing - S := 36.00. in Shelving Loads: Maximum Live Load on each shelf is 125 Ibs: Weight per shelf - Wtl := 125• Ib Load in psf - Wti w•d Design Live Load on Shelf- LL := LLi Dead Load on Shelf - DL := 2.50• psf Section Properties of Double Rivet 'L' Post : Wti = 1251b LLi = 33.3333. psf LL = 33.3333. psf Modulus of Elasticity of Steel - E := 29000• ksi b := 1.5 in h:= 1.5•in Steel Yield Stress - Fy:= 33• ksi ry:= 0.47 in Section Modulus in x and y - SX := 0.04. in3 rX := 0.47• in Moment of Inertia in x and y - IX := 0.06. in4 t := 0.075• in Full Cross Sectional Area - AP := 0.22• in2 hp := 1.42 in b� := 1.42• in Length of Unbraced Post- LX:= S = 36• in Ly:= S = 36• in Lt:= S = 36• in Effective Length Factor- KX:= 1.0 Ky:= 1.0 Kt:= 1.0 Section Properties Continued: Density of Steel - psteel := 490. pcf Weight of Post - Wp := psteel• Ap • ht Wp = 6.74. lb Vertical DL on Post - Pd := DL• w• .25d• N + Wp Pd = 16.11 lb Vertical LL on Post- Pi := LL•w• .25. d• N P1 = 1251b Total Vertical Load on Post - Pp := Pd + Pi Pp = 141.11 • Ib 12 ;ECLIPSE ENGINEERING LULULEMON #10503 9/10/2014 TUKWILA, WA Rolf Armstrong, PE Floor Load Calculations : Weight of Mobile Carriage: Wc:= 0• Ib Total Load on Each Unit: W := 4. Pp + W W = 564.45 lb Area of Each Shelf Unit: Au := w•(d + 9in) AU = 5.625ft2 Floor Load under Shelf: PSF := PSF = 100• psf Au NOTE: SHELVING LIVE LOAD IS CONSISTENT WITH 100 psf REQ'D FOR RETAIL FLOOR LOADING Find the Seismic Load using Full Design Live Load : ASCE-7 Seismic Design Procedure: Importance Factor- IE:= 1.0 Determine Ss and Si from maps - Ss := 1.458 51:= 0.544 Determine the Site Class - Class D Determine Fa and Fv, - Fa := 1.000 F,:= 1.500 Determine SMs and SM1 _ SMS := Fa• Ss SM1:= F�• S1 SMS = 1.458 SM1= 0.816 2 Determine SDs and SDI _ SDs 3 • SMS SDI 3 • SM1 SDS = 0.972 SDI = 0.544 Structural System - Section 15.5.3 ASCE-7: 4. Steel Storage Racks Total Vertical LL Load on Shelf - Total Vertical DL Load on Shelf - R:= 4.0 Rp:= R Wi:= LL•w•d S2p:= 2 ap:= 2.5 W Wd := DL w d + 4.— N Seismic Analysis Procedure per ASCE-7 Section 13.3.1: Average Roof Height - hr := 20.0.ft Height of Rack Attachment- z:= 0•ft Seismic Base Shear Factor - Shear Factor Boundaries - 0.4•ap•SDS z Vt:= C1 + 2• h r Rp Ip Vtmin := 0.3. SDS• Ip Vtmax := 1.6. SDS• Ip Vt := if(Vt > Vtmax , Vtmax , Vt) Vt:= if(Vt < Vtmin, Vtmin, Vt) Cd:= 3.5 Ip := 1.0 WI = 1251b Wd = 16.11lb (0'-0" For Ground floor) Vt = 0.243 Vtmin = 0.292 Vtmax = 1.555 Vt = 0.292 13 ECLIPSE ENGINEERING Seismic Loads Continued : LULULEMON #10503 911012014 TUKWILA, WA Rolf Armstrong, PE v For ASD, Shear may be reduced - Vp := t = 0.208 1.4 Seismic DL Base Shear - Vtd := Vp• Wd• N = 13.421b DL Force per Shelf : Fd := Vp• Wd = 3.361b Seismic LL Base Shear - Vtl := Vp• WI• N = 104.14 lb LL Force per Shelf : FI := Vp• WI = 26.041b 0.67 " LL Force per Shelf : FI.67 := 0.67. Vp• WI = 17.44Ib Force Distribution per ASCE-7 Section 15.5.3.3: Operating Weight is one of Two Loading Conditions : Condition #1: Each Shelf Loaded to 67% of Live Weight Cumulative Heights of Shelves - H1:= 0.0•S+ 1.0.S+ 2.0•S+ 3.0•S H2:= 0 H := H1 + H2 H = 18ft Total Moment at Shelf Base - Mt:= H. Wd + H• 0.67• WI Mt = 1797.52 ft. lb Vertical Distribution Factors for Each Shelf - Total Base Shear- Vtotal Vtd + 0.67• Vtl Vtotai = 83.21b Wd•0.0•S+ WI.0.67.0.0.S Wd. 1.0. S + WI.0.67.1.0•S C1:= = 0 C2:= — 0.167 Mt Mt F1 C1•(Vtotal) = 0 Wd•2.0•S + WI.0.67.2.0•S C3:= M — 0.333 t F3 C3•(Vtotal) = 27.731b c1+C2+C3+C4=1 F2 := C2 (Vtotal) = 13.871b Wd•3.0•S+ WI.0.67.3.0•S C4:— M = 0.5 t F4 C4•(Vtotal) = 41.61b 14 ECLi FSE ENGINEERING LULULEMON #10503 9/10/2014 TUKWILA, WA Rolf Armstrong, PE Force Distribution Continued : Condition #2: Top Shelf Only Loaded to 100% of Live Weight Total Moment at Base of Shelf - Total Base Shear - Cia:= Wd•0.0•S+ 0.Wl•0.0•S —0 Mta Fla := Cia' (Utota12 = 0 Mta :=(N— 1)•S.Wd+(N— 1)•S•11111= 1270ft.Ib Vtotal2 Vtd + FI Utotal2 = 39.46Ib Ctsa Wd•(N — 1).S + W1•(N — 1)•S Mta Ftsa Ctsa' (Vtotal2) = 39.461b Condition #1 Controls for Total Base Shear By Inspection, Force Distribution for intermediate shelves without LL are negligible. Moment calculation for each column is based on total seismic base shear. Column at center of rack is the worst case for this shelving rack system. Column Design in Short Direction : Bending Stress on Column - Allowable Bending Stress - Ms: 4' 2'(Vtotal) = 31.2ft.Ib Fb := 0.6. Fy = 19.8• ksi fbX := Ms• SX 1 = 9.36• ksi Bending at the Base of Each Column is Adequate Deflection of Shelving Bays - worst case is at the bottom bay l 3 := (Vtd + VtIJ S — 0.2627• in S = 137.0378 12• E. IX Zt:= 0•(N — 1) = 0.7881•in Da := 0.05•ht= 5.4•in if(Ot < Da, "Deflection is Adequate" , "No Good") = "Deflection is Adequate" Moment at Rivet Connection: Shear on each rivet - 2 dr:= 0.25•in Vr:= Ms — 249.61b Ar:= dr — 0.0491.in2 1.5• in 4 Steel Stress on Rivet - Ultimate Stress on Rivet (SAE C1006 Steel) - Omega Factor (ASD) - Allowable Stress on Rivet - Vr fv:= —= 5.08•ksi Ar Fur:= 47.9ksi 12r:= 2.0 Fvr:= 0.4• Fur' fr 1 = 9.58. ksi f Ratio of Allowable 1 Ultimate Stress - - = 0.5308 Fvr RIVET CONNECTION IS ADEQUATE FOR MOMENT CONNECTION FROM BEAM TO POST 15 ECLI PS E LULULEMON #10503 9/10/2014 ENGINEERING TUKWILA, WA Rolf Armstrong, PE Seismic Uplifton Shelves : Seismic Vertical Component: Vertical Dead Load of Shelf: Ev:= 0.2•Sps•(DL + LL)•w•d D:= (DL+ LL)•w•d E„ = 26.1225 lb D = 134.3751b Note: since the shelf LL is used to generate the seismic uplift force, it may also be used to calculate the net uplift load. For an empty shelf, only the DL would be used, but the ratio of seismic uplift will be the same. Net Uplift Load on Shelf: Fu := E„ — 0.6• D Fu = —54.5025 lb Note: This uplift load is for the full shelf. Each shelf will be connected at each comer. Number of Shelf Connections: Uplift Force per Corner: Nc:= 4 Fu Fuc:= INC Fuc =—13.62561b NOTE: Since the uplift force is negative, a mechanical connection is not required. 16 ECLI PSE ENGINEERING LULULEMON #10503 9/1012014 TUKWILA, WA Rolf Armstrong, PE Find Allowable Axial Load for Column : Allowable Buckling Stresses - 7'2• E — 48.79• ksi Distance from Shear Center to CL of Web via X-axis t hc2 bc2 ec:= 4• Ix Qex 6ex.x = 48.79• ksi ec = 1.2706• in Distance From CL Web to Centroid - x := 0.649• in — 0.5• t x0 = 0.6115. in Distance From Shear Center xo := x. + eo xo = 1.8821. in to Centroid - Polar Radius of Gyration - ro := Jrx2 + ry2 + x02 ro = 1.996. in Torsion Constant - J:= 3 • (2• b• t3 + h• t3) J = 0.00063 • in4 Warping Constant - CW t• b3. h2 b. t + 2. h. t )CW = 0.0339• in6 12 (1313. 6•+ h.t ) Shear Modulus - G := 11300• ksi zrECl vt:= 1 G•J+ ot= 16.7003.ksi Ap•ra2 _ (Kt•Li) 2 J :=1— Fet 2R •L(°ex + at) — J(Crex + Qt)2 - 4• R• (Tex'v] Elastic Flexural Buckling Stress - Allowable Compressive Stress - Factor of Safety for Axial Comp. - Fe := if(Fet < 0ex, Fete Qex) F„:=ifFe>Fy,F• 1- 2 y 4•Fe) S2o := 1.92 3 = 0.1109 Fet = 12.7151 • ksi Fe = 12.7151 • ksi Fjl Fo= 12.7151•ksi 17 ECLI PSE ENGINEERING LULULEMON #10503 9110/2014 TUKWILA, WA Rolf Armstrong, PE Find Effective Area - Determine the Effective Width of Flange - Flat width of Flange - wf:= b - 0.5• t Flange Plate Buckling Coefficient- kf:= 0.43 Flange Slendemess Factor- %f:= 1.052 wf r'r) t r 0.22) 1 Pf:= 1- — \ Xf ) of Effective Flange Width - be := if(xf > 0.673, pf wf, wf) Determine Effective Width of Web - Flat width of Web- ww:= h - t Web Plate Buckling Coefficient - kw := 0.43 Web Slenderness Factor - Effective Web Width - Effective Column Area - Nominal Column Capacity - Allowable Column Capacity - Check Combined Stresses - i2• E. Ix Pcrx:= Kx• Lx)2 Pcr Pcrx Magnification Factor - Combined Stress: 1.052 ww Fn �w t E 0.22) 1 Pw:= 1- X„„ )Xw he := if(xw > 0.673, Pw•ww, Ae := t•(he + be) Pn:= Ae•Fn Pn := - 0 Pc,, = 1.33 x 104 lb Pcr = 13250.866 lb a:= 1- Pp) PC r ) Pp + Cm • fbx — 0.509 Pa Fb•a wf = 1.4625• in Xf = 0.6551 pf = 1.0139 be = 1.4625. in ww = 1.425• in %w = 0.6383 pw = 1.0267 ww) he = 1.425• in Ae = 0.2166•in2 Pe = 27541b Pa = 14341b a= 0.98 Cm := 0.85 MUST BE LESS THAN 1.0 Final Design: 'L' POSTS WITH BEAM BRACKET ARE ADEQUATE FOR REQD COMBINED AXIAL AND BENDING LOADS NOTE: PP is the total vertical Toad on post, not 67% live load, so the design is conservative 18 Tension (Uplift) Force at Corner: Thickness of Angle: Width of Angle Leg: Distance out to Tension Force: Design Moment on Angle: Allowable Bending Stress: Ultimate Tensile Strength of Clip: Effective Net Area of the Clip: ':ECLIPSE ENGINEERING LULULEMON #10503 9/10/2014 TUKWILA, WA Rolf Armstrong, PE STEEL BASE CLIP ANGLE DESIGN -A1018 PLATE STEEL Fyp : = 36• ksi T := 75• Ib to := 0.075. in ba := 1.25• in L := 0.75• in M:= T•L= 4.6875ft.Ib Fb := 0.90. Fyp = 32.4. ksi F„ p := 65. ksi Yield Stress of Angle Steel: 14 ga Foot Plate Length of Angle Section: La := 1.375• in Section Modulus of Angle Leg: ba• ta2 Za:= — 0.0018•in3 4 Bending Stress M on Angle: fb := — = 32. ksi Ratio of Allowable Loads: Gross Area of the Clip: Aec := Ago — [ta•(0.375• in)] = 0.0656. in2 Za fb — = 0.988 Fb MUST BE LESS THAN 1.00 Age := ba• to = 0.0938• in2 Limiting Tensile Strength of Clip: Tema, := mini(0.90. Fyp• Ago), (0.75. Fup• Aec)] = 3037.5 Ib 14 GA. ANGLE CLIP WILL DEFORM PRIOR TO ANCHOR PULLING OUT OF CONCRETE, BUT NOT WILL NOT TEAR COMPLETELY THROUGH, THEREFORE CLIPS ARE ADEQUATE. BEARING STRENGTH OF SCREW CONNECTIONS - AISC 37 Specified Yield Stress of Post - Width of Screw - 14 GA Thickness - Projected Bearing Area - Single Screw Fys:= 36ksi wss:= 0.25in tss:= 0.075in Abs wss• tss = 0.0188. in2 Nominal Bearing Strength - Rns 1.8. Fys• Abs = 12151b Omega for Bearing (ASD) & Phi for Bearing (LRFD) - Allowable Bearing Strength - Ras Rns• (1)s = 911.25 Ib Double Screw Fyd := 36ksi wsd := 0.50in tsd := 0.075in Abd:= Wsd•tsd = 0.0375•in2 Rnd := 1.8. Fyd• Abd = 24301b 12s:= 2.0 (1)s:= 0.75 Rad Rnd• ,ztos = 1822.5 Ib SCREW CONNECTION CAPACITIES (1/4"4:i SCREW IN 14 GA STEEL): Converted to LRFD for comparison to'Hilti' A.B. Single Screw Double Screw Allowable Tension - Tss Qs. ks• 3281b Allowable Shear- Tsd (131s•6561b Ref Attached'Scafco' Table for V & T Values Vss :_ Si,. (1)s. 8661b Vsd :_ �s (I)s• 1732Ib The allowable shear values for (1)1/4" dia. screw exceeds the allowable bearing strength of the connection. Therefore, bearing strength govems for screw connection capacity. 19 14 ECLI PSE ENGINEERING LULULEMON #10503 9/10/2014 TUKWILA, WA Rolf Armstrong, PE BOLT CONNECTION CAPACITIES (3/8" DIA. x 2" HILTI KB-TZ): Single Anchor Double Anchor Ref Attached 'HILTI' PROFIS calcs Tas := 1051• Ib Tad := 1993• Ib for V & T Values Allowable Tension Force - Allowable Shear Force - Vas := 1466• Ib Vad := 1938• Ib DETERMINEALLOWABLE TENSION/SHEAR FORCES FOR CONNECTION: Single Anchor Double Anchor Allowable Tension Force - Tas := min(Tas, Vss, Ras) = 911.25 Ib Tad := min(Tad, Vsd, Rad) = 1822.5 Ib Allowable Shear Force - Vas := min(Vas, Tss) = 4921b Vad := min(Vad, Tad) = 9841b USE: HILTI KB-TZ ANCHOR (or equivalent) - 318" x 2" long anchor installed per the requirements of Hilti to fasten fixed shelving units to existing concerete slab. Use 114" dia. screw to fasten base to 14 GA shelf member. 20 ECLIPSE ENNGINEERING. LULULEMON #10503 911012014 TUKWILA, WA Rolf Armstrong, PE STEEL STORAGE RACK DESIGN - cont'd Find Overturning Forces : Total Height of Shelving Unit- Ht:= ht = 9ft Width of Shelving Unit- w = 2.5ft Depth of Shelving Unit - d = 1.5ft WORST CASE Number of Shelves - N = 4 Vertical Shelf Spacing - S = 36. in Height to Top Shell Center of G - htop:= Ht htop = 9ft Height to Shelf Center of G - ho N + 1� S ho = 7.5.ft 2 From Vertical Distribution of Seismic Force previously calculated - Controlling Load Cases - Weight of Rack and 67% of LL - W := (Wd + 0.67. Wi)• N W = 399.45 Ib Seismic Rack and 67% of LL - V:= Vtd + 0.67• Vti V = 83.21b Ma := Fi• 0.0• S + F2.1.0• S + F3.2.0• S + F4.3.0• S Mb:= 0 Overturning Rack and 67% of LL - M := Ma + Mb = 582.4ft• Ib Weight of Rack and 100% Top Shelf - Wa := Wd• N + WI Wa = 189.45 Ib Seismic Rack and 100% Top Shelf - Va := Vtd + Fl Va = 39.46 Ib Overturning Rack and 100% Top Shelf - Ma := Vtd he + Fi• htop Ma = 335 ft. Ib Controlling Weight - Wo := if(W > Wa, W, Wa) Wo = 399.45 Ib Controlling Shear- V, := if(V > Va, V, Va) Vo = 83.21b Controlling Moment - Mot:= if(M > Ma, M, Ma) Mot = 582.4ft• Ib Tension Force on Column Anchor- T := Mot — 0.60• Wo T = 268.43 Ib per side of shelving unit d 2 Tmax:= if(T < 0• Ib, 0• Ib, T) Tmax = 268.43 Ib Vc Shear Force on Column Anchor - Vm,:= Vmax = 41.6Ib 2 USE: HILTI KWIK BOLT TZ ANCHOR (or equivalent) - USE 3/8"4 x 2" embed installed per the requirements of Hilti Combined Loading (Single Anchor / Screw) - Combined Loading (Double Anchor / Screw) - Tmax 1� 2.0.7•Tas) ' Vmax = 0.08 < 1.00 OKAY 2.0.7•Vas) ' ' 1� max + Vmax = 0.08 <1.00 OKAY �1.0.7•Tad ) 1.0.7•Vad) 3 21 3ECLIPSE ENGtNEER.ING LULULEMON #10503 9/10/2014 Connection from Steel Racks to Wall TUKWILA, WA Seismic Analysis Procedure per ASCE-7 Section 13.3.1: Average Roof Height - Height of Rack Attachments - Seismic Base Shear Factor - Shear Factor Boundaries - Seismic Coefficient - Number of Shelves - Weight per Shelf - Total Weight on Rack - Seismic Force at top and bottom - Connection at Top: Standard Stud Spacing - Width of Rack - Number of Connection Points - on each rack Force on each connection point - Capacity per inch of embedment - Rolf Armstrong, PE hr = 20ft zb := z + ht zb = 9 ft At Top for fixed racks connected to walls 0.4 ap• Sips zb Vt:= 1+2•— Vt=0.462 Rp hr ) Ip Vtmin := 0.3. Sips• I Vtmax 1.6• Sips• Ip Vt:= if(Vt > Vtmax, Vtmax, Vt) Vt:= if(Vt < Vtmin, Vtmin, Vt) Vt = 0.462 N=4 Wtl = 1251b WT:= 0.667.4. Pp 0.7. Vt. WT Tv:= 2 Sstud 16. in w = 2.5 ft Nc:= max 2, floor w 11 Sstud ))] Tv Fc: N— c Ws := 135• lb— in F Required Embedment- ds:= c Ws For Steel Studs: Pullout Capacity in 20 ga studs - per Scafco Vtmin = 0.292 Vtmax = 1.555 Vt = 0.462 WT = 376.49 lb Tv = 60.841b Ns = 2 F, = 30.421b ds = 0.225. in T20:= 84• lb For #10 Screw- per Scafco MIN #10 SCREW ATTACHED TO EXISTING WALL STUD IS ADEQUATE TO RESIST SEISMIC FORCES ON SHELVING UNITS. EXPANSION BOLT IS ADEQUATE BY INSPECTION AT THE BASE 22 Ecli se Engineering, Inc. LULULEMON #10503 Design Maps Summary Report • -n Iting Engineers TUKWILA, WA User -Specified Input Building Code Reference Document 2012 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.45858°N, 122.26123°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III 0 Vashon TRAMP HARBOR mapquest USGS-Provided Output SS = 1.458 g Si = 0.544 g SMS = 1.458 g SM1 = 0.816 g I 020141 1p SDS = 0.972 g SD1 = 0.544 g 09110/2014 MLG East Renton St Highlands 0 - AM ERICA 0 MapQuest For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. NICER Response Spectrum 1.65 1.50 1.35 1.20 1.05 0.90 y 0.75 0.60 0.45 0.30 0.15 0.00 0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 Period, T (sec) 2.00 Design Response Spectrum 1.10 1.00 0.90 0.80 0.70 0.60 tiM N 0.50 0.40 0.30 0.20 0.10 0.00 0.00 0.20 0.40 0.60 0.90 1.00 1.20 1.40 1.60 1.80 Period, T (sec) 2.00 Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. Consulting Engineers Thickness - Steel Components Steel Thickness Table 18 0.0179 27 0.0269 D20 0.0179 30EQD 0.0223 0.0296 0.0280 0.0329 43EQS 0.0380 43 0.0428 54 0.0538 68 0.0677 97 0.0966 118 0.1180 127 0.1270 30 33EQS 33 0.0188 0.0283 0.0188 0.0235 0.0312 0.0295 0.0346 0.0400 0.0451 0.0566 0.0713 0.1017 0.1242 0.1337 0.0843 0.0796 0.0844 0.0820 0.0781 0.0790 0.0764 0.0712 0.0712 0.0849 0.1069 0.1525 0.1863 0.2005 TUKWILA, WA 25 22 20-Drywall 20-Drywall 20 - Drywall 20-Structural 20 - Structural 18 18 16 14 12 10 - SSMA 10-SCAFCO 7�bfe Notes Minimum thickness represents 95 percent of the design thickness and is the minimum acceptable thickness delivered to the jobsite based on Section A2.4 of AISI S100-07. The tables in this catalog are calculated based on inside corner radii listed in this table. The inside corner radius is the maximum of/3, - t/2 or 1.5t, truncated after the fourth decimal place (t = design thickness). Centerline bend radius is calculated by adding half of the design thickness to listed corner radius. Screw Capacities 18 27 D20 30EQD 30 33E0S 33 43EQS 43 54 68 97 118 33 33 57 57 33 57 33 57 33 50 50 50 50 45 45 65 65 45 65 45 65 45 65 65 65 65 60 111 87 122 129 171 151 270 224 455 576 821 1003 127 50 65 1079 aab!e Notes General Product Information 43EQS 0.0400 57 65 639 1106 696 849 43 0,0451 33 45 601 864 544 663 54 0.0566 50 65 1188 1566 985 1202 68 0.0713 50 65 1562 1972 I 1241 1514 97 0.1017 50 65 1269 1269 - 1 118 0.1242 50 65 1550 1550 - 127 0.1337 50 1668 1668 Table Notes 1. Capacities based on AISI S100-07 Section E2.4 for fillet welds and E2.5 for flare groove welds. 2. When connecting materials of different steel thicknesses or tensile strengths, use the values that correspond to the thinner or lower yield material. 3. Capacities are based on Allowable Strength Design (ASD) and Include appropriate safety factors. 4. Weld capacities are based on either'/32" or Y" diameter E60 or E70 electrodes. For thinner materials, 0.030" to 0.035" diameter wire electrodes may provide best results. 5. Parallel capacity Is considered to be loading in the direction of the length of the weld. 6. For welds greater than 1", equations E2.4-1 and E2.4-2 must be checked. 7. For flare groove welds, the effective throat of weld is conservatively assumed to be less than 2t. B. *Flare grove weld capacity for material thicker than 0.10" requires engineering judgement to determine leg of welds (W, and W,). Allowable Screw Connection Capacity (Ibs per screw) r 33 66 39 71 46 76 52 81 60 50 122 59 131 69 139 78 150 90 48 95 57 102 66 109 75 117 87 60 133 71 143 82 152 94 164 108 55 141 65 151 76 161 86 174 100 75 187 89 201 103 214 117 231 136 61 164 72 177 84 188 95 203 110 102 295 121 317 140 338 159 364 184 79 244 94 263 109 280 124 302 144 144 496 171 534 198 570 225 613 261 181 684 215 755 250 805 284 866 328 259 976 307 1130 356 1285 405 1476 468 316 1192 375 1381 435 1569 494 1816 572 340 1283 404 1486 468 1689 532 1955 616 1. Capacities based on AISI 5100-07 Section E4. See table on page 5 for design thicknesses. 2. When connecting materials of different steel thicknesses or tensile strengths, use the lowest values. Tabulated values assume two sheets of equal thickness are connected. 3. Capacities are based on Allowable Strength Design (ASD) and include safety factor of 3.0. 4. Where multiple fasteners are used, screws are assumed to have a center -to -center spacing of at least 3 times the nominal diameter (d) 5. Screws are assumed to have a center -of -screw to edge -of -steel dimension of at least 1.5 times the nominal diameter (d) of the screw. Load Paths All product load capacities are calculated per North American Specification for the Design of Cold Formed Steel Structural Members. The 2007 edition (here after referred to as simply "NASPEC"). Illustrations of load instructions are amongst their relative product load tables located throughout this catalog. Figure to the right demonstrates different types of load directions mentioned in this catalog. t. f = Out -of -plane lateral load t 12 = In -Plane lateral load = Direct vertical and uplift load 6. Tension capacity is based on the lesser of pullout capacity in sheet closest to screw tip, or pullover capacity for sheet closest to screw head (based on head diameter shown). Note that for all tension values shown in this table, pullover values have been reduced by 50 percent assuming eccentrically loaded connections that produce a non -uniform pull -over force on the fastener. 7. Higher values, especially for screw strength, may be obtained by specifying screws from a specific manufacturer. See manufacturer's data for specific allowable values and Installation instructions. CESCAFLO. Stvrl 5t,W Cangrwn_y Eclipse Engineering, Inc. LULULEMON #10503 Consulting Engineers TUKWILA, WA 1■■111IT1 09/10/2014 MLG www.hilti.us Profis Anchor 2.4.6 ECLIPSE ENGINEERING. INC. 1 Company: Specifier: Address: Phone I Fax: E-Mail: 541-389-96591 Page: Project: Sub -Project I Pos. No.: Date: 5/27/2014 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ - CS 3/8 (2) Effective embedment depth: hetact = 2.000 in.. hnom = 2.313 in. Material: Carbon Steel Evaluation Service Report: ESR-1917 Issued I Valid: 5/1/2013 15/1/2015 Proof: design method ACI 318-11 / Mech. Stand-off installation: - (Recommended plate thickness: not calculated) Profile: no profile Base material: cracked concrete. 2500. fc' = 2500 psi; h = 4.000 in. Installation: hammer drilled hole. installation condition: dry Reinforcement: tension: condition B. shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Seismic loads (cat. C. D. E. or F) Tension load: yes (D.3.3.4.3 (b)) Shear load: yes (D.3.3.5.3 (a)) Geometry [in.] & Loading [Ib, in.Ib] Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG. FL-9494 Schaan Hilti is a registered Trademark of Hilti AG. Schaan Eclipse Engineering, Inc. LULULEMON #10503 Consulting Engineers TUKWILA, WA 09/10/2014 MLG www.hilti.us Profis Anchor 2.4.6 ECLIPSE ENGINEERING. INC. 2 Company: Specifier: Address: Phone I Fax: E-Mail: 541-389-9659 Page: Project: Sub -Project I Pos. No.: Date: 5/27/2014 2 Proof I Utilization (Governing Cases) Design values [lb] Utilization Loading Proof Load Capacity ON 113v [%] Status Tension Pullout Strength 300 1107 28 / - OK Shear Steel Strength 200 1466 - / 14 OK Loading 1/1.1 Pv Utilization IN,v [%] Status Combined tension and shear loads 0.271 0.136 5/3 15 OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles. formulas and security regulations in accordance with Hilti's technical directions and operating. mounting and assembly instructions. etc.. that must be strictly complied with by the user. All figures contained therein are average figures. and therefore use -specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore. you bear the sole responsibility for the absence of errors. the completeness and the relevance of the data to be put in by you. Moreover. you bear sole responsibility for having the results of the calculation checked and cleared by an expert. particularly with regard to compliance with applicable norms and permits. prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors. the correctness and the relevance of the results or suitability for a specific application. You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular. you must arrange for the regular backup of programs and data and. if applicable. carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software. you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences. such as the recovery of lost or damaged data or programs. arising from a culpable breach of duty by you. Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG. FL-9494 Schaan Hilti is a registered Trademark of Hilti AG. Schaan Eclipse Engineering, Inc. LULULEMON #10503 Consulting Engineers TUKWILA, WA 09/10/2014 MLG www.hilti.us Profis Anchor 2.4.6 ECLIPSE ENGINEERING. INC. 1 Company: Specifier: Address: Phone I Fax: E-Mail: 541-389-96591 Page: Project: Sub -Project I Pos. No.: Date: 5/27/2014 Specifiers comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ - CS 3/8 (2) Effective embedment depth: hef,act = 2.000 in.. hnom = 2.313 in. Material: Carbon Steel Evaluation Service Report ESR-1917 Issued I Valid: 5/1/2013 15/1/2015 Proof: design method ACI 318-11 / Mech. Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.074 in. Anchor plate: Ix x ly x t = 3.000 in. x 6.500 in. x 0.074 in.; (Recommended plate thickness: not calculated) Profile: no profile Base material: cracked concrete. 2500. fo' = 2500 psi; h = 4.000 in. Installation: hammer drilled hole. installation condition: dry Reinforcement: tension: condition B. shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Seismic loads (cat. C. D. E. or F) Tension load: yes (D.3.3.4.3 (b)) Shear load: yes (D.3.3.5.3 (a)) Geometry [in.] & Loading [Ib, in.lb] w 8 5.5 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG. FL-9494 Schaan Hilti is a registered Trademark of Hilti AG. Schaan Eclipse Engineering, Inc. LULULEMON #10503 Consulting Engineers TUKWILA, WA i-u• rri 09/10/2014 MLG www.hilti.us Profis Anchor 2.4.6 ECLIPSE ENGINEERING. INC. 2 Company: Specifier: Address: Phone I Fax: E-Mail: 541-389-96591 Page: Project: Sub -Project I Pos. No.: Date: 5/27/2014 2 Proof I Utilization (Governing Cases) Design values [lb] Utilization Loading Proof Load Capacity pN / pv [%] Status Tension Pullout Strength 150 1107 14 / - OK Shear Concrete edge failure in direction x+ 200 1966 - / 11 OK Loading PN pv Utilization pN,v [%] Status Combined tension and shear loads 0.140 0.102 5/3 6 OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles. formulas and security regulations in accordance with Hilti's technical directions and operating. mounting and assembly instructions. etc.. that must be strictly complied with by the user. All figures contained therein are average figures. and therefore use -specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore. you bear the sole responsibility for the absence of errors. the completeness and the relevance of the data to be put in by you. Moreover. you bear sole responsibility for having the results of the calculation checked and cleared by an expert. particularly with regard to compliance with applicable norms and permits. prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors. the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular. you must arrange for the regular backup of programs and data and. if applicable. carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software. you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences. such as the recovery of lost or damaged data or programs. arising from a culpable breach of duty by you. TENSION LOAD & CAPACITY SHOWN ARE "PER ANCHOR" VALUES. SHEAR LOAD & CAPACITY SHOWN ARE "PER ANCHOR PAIR" VALUES. Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG. FL-9494 Schaan Hilti is a registered Trademark of Hilti AG. Schaan Eclipse Engineering, Inc. LULULEMON #10503 Consulting Engineers TUKWILA, WA 09/10/2014 MLG www.hilti.us Profis Anchor 2.4.6 ECLIPSE ENGINEERING. INC. Page: 1 Project: Sub -Project I Pos. No.: 541-389-9659 I Date: Company: Specifier: Address: Phone I Fax: E-Mail: 5/27/2014 Specifiers comments: 1 Input data Anchor type and diameter: KWIK HUS-EZ (KH-EZ) 3/8 (2 1/2) Effective embedment depth: hef.act = 1.860 in.. hnom = 2.500 in. Material: Carbon Steel Evaluation Service Report: ESR-3027 Issued I Valid: 8/1/2012 112/1/2013 Proof: design method ACI 318-11 / Mech. Stand-off installation: - (Recommended plate thickness: not calculated) Profile: no profile Base material: cracked concrete. 2500. fc' = 2500 psi; h = 4.000 in. Installation: hammer drilled hole. installation condition: dry Reinforcement: tension: condition B. shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Seismic loads (cat. C. D. E. or F) Tension load: yes (D.3.3.4.3 (b)) Shear load: yes (D.3.3.5.3 (a)) Geometry [in.] & Loading [Ib, in.Ib] gfi •,x Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG. FL-9494 Schaan Hilti is a registered Trademark of Hilti AG. Schaan Eclipse Engineering, Inc. LULULEMON 1110503 Consulting Engineers TUKWILA, WA 09110/2014 MLG www.hilti.us Profis Anchor 2.4.6 Company: Specifier: Address: Phone I Fax: E-Mail: ECLIPSE ENGINEERING. INC. 541-389-96591 Page: Project: Sub -Project I Pos. No.: Date: 2 5/27/2014 2 Proof I Utilization (Governing Cases) Design values [lb] Utilization Loading Proof Load Capacity pN / pv [%] Status Tension Concrete Breakout Strength 300 1051 29 / - OK Shear Pryout Strength 200 1509 - / 14 OK Loading PN pv Utilization pN,v [%] Status Combined tension and shear loads 0.285 0.133 5/3 16 OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! 4 Remarks; Your Cooperation Duties Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles. formulas and security regulations in accordance with Hilti's technical directions and operating. mounting and assembly instructions. etc.. that must be strictly complied with by the user. All figures contained therein are average figures. and therefore use -specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore. you bear the sole responsibility for the absence of errors. the completeness and the relevance of the data to be put in by you. Moreover. you bear sole responsibility for having the results of the calculation checked and cleared by an expert. particularly with regard to compliance with applicable norms and permits. prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors. the correctness and the relevance of the results or suitability for a specific application. You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular. you must arrange for the regular backup of programs and data and. if applicable. carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software. you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences. such as the recovery of lost or damaged data or programs. arising from a culpable breach of duty by you. Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG. FL-9494 Schaan Hilti is a registered Trademark of Hilti AG. Schaan Eclipse Engineering, Inc. LULULEMON #10503 Consulting Engineers TUKWILA, WA MILT' II 09/10/2014 MLG www.hilti.us Profis Anchor 2.4.6 ECLIPSE ENGINEERING 1 Company: Specifier: Address: Phone I Fax: E-Mail: 541-389-96591 Page: Project: Sub -Project I Pos. No.: Date: 5/27/2014 Specifiers comments: 1 Input data Anchor type and diameter: KWIK HUS-EZ (KH-EZ) 3/8 (2 1/2) Effective embedment depth: hetact = 1.860 in.. hnom = 2.500 in. Material: Carbon Steel Evaluation Service Report: ESR-3027 Issued I Valid: 8/1/2012 112/1/2013 Proof: design method ACI 318-11 / Mech. Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.074 in. Anchor plate: IX x 1, x t = 3.000 in. x 7.000 in. x 0.074 in.; (Recommended plate thickness: not calculated) Profile: no profile Base material: cracked concrete. 2500. fc' = 2500 psi; h = 4.000 in. Installation: hammer drilled hole. installation condition: dry Reinforcement: tension: condition B. shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Seismic loads (cat. C. D. E. or F) Tension load: yes (D.3.3.4.3 (b)) Shear load: yes (D.3.3.5.3 (a)) Geometry [in.] & Loading [Ib, in.Ib] Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG. FL-9494 Schaan Hilti is a registered Trademark of Hill! AG. Schaan Eclipse Engineering, Inc. LULULEMON #10503 Consulting Engineers TUKWILA, WA 09/10/2014 MLG www.hilti.us Profis Anchor 2.4.6 ECLIPSE ENGINEERING 2 Company: Specifier: Address: Phone I Fax: E-Mail: 541-389-96591 Page: Project: Sub -Project I Pos. No.: Date: 5/27/2014 2 Proof I Utilization (Governing Cases) Design values [lb] Utilization Loading Proof Load Capacity RN / [iv [%] Status Tension Concrete Breakout Strength 300 1993 16 / - OK Shear Concrete edge failure in direction x+ 200 1938 - / 11 OK Loading PN (iv Utilization !INN [%] Status Combined tension and shear loads 0.151 0.103 5/3 7 OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! 4 Remarks; Your Cooperation Duties Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles. formulas and security regulations in accordance with Hilti's technical directions and operating. mounting and assembly instructions. etc.. that must be strictly complied with by the user. All figures contained therein are average figures. and therefore use -specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore. you bear the sole responsibility for the absence of errors. the completeness and the relevance of the data to be put in by you. Moreover. you bear sole responsibility for having the results of the calculation checked and cleared by an expert. particularly with regard to compliance with applicable norms and permits. prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors. the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular. you must arrange for the regular backup of programs and data and. if applicable. carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software. you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences. such as the recovery of lost or damaged data or programs. arising from a culpable breach of duty by you. Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG. FL-9494 Schaan Hilti is a registered Trademark of Hilti AG. Schaan City of Tukwila Department of Community Development 3/2/2015 MELANI DANNENBERG 20521 EARL ST TORRANCE, CA 90503 RE: Permit No. D14-0313 LULULEMON RACKS 21 SOUTHCENTER MALL Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 4/22/2015. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 4/22/2015, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, �P Bill Rambo Permit Technician File No: D14-0313 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY Building Division Public Works PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0313 DATE: 09/25/2014 PROJECT NAME: LULULEMON RACKS SITE ADDRESS: 21 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 6 (M.3itt'l 1111 AWC 10'01° N Fire Prevention 1111 Structural n Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 09/30/14 Structural Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/28/14 Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 R MILLER INC Page 1 of 3 Washington State Department of Labor & Industries R MILLER INC Owner or tradesperson MILLER, ROBIN L Principals MILLER, ROBIN L, PRESIDENT MILLER, CAROL M, VICE PRESIDENT Doing business as R MILLER INC WA UBI No. 600 389 405 18321 98TH AVE NE STE 1 BOTHELL, WA98011 425-775-3822 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. RMILLMI871 NH Effective — expiration 08/08/2013— 08/08/2015 Bond Merchants Bonding Co (Mutual) Bond account no. WA28637 Received by L&I 08/08/2013 Insurance American Fire & Casualty Co Policy no. BKA52904719 Received by L&I 12/09/2013 $12,000.00 Effective date 07/31/2013 Expiration date Until Canceled $1,000,000.00 Effective date 01/01/2013 Expiration date https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600389405&LIC=RMILLMI871NH&SAW= 10/14/2014