Loading...
HomeMy WebLinkAboutPermit D14-0318 - KOTIS DESIGN EXPANSION - EXPANSIONKOTIS DESIGN EXPANSION 1165 ANDOVER PARK W D14-0318 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 3523049097 Permit Number: D14-0318 1165 ANDOVER PARK W Project Name: KOTIS DESIGN EXPANSION Issue Date: 10/22/2014 Permit Expires On: 4/20/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: CWWA SOUTHCENTER 4 LLC PO BOX B-3879 C/O EQUITY OFFICE MGMT LLC, CHICAGO, WA, 60690 DAVID KEHLE, ARCHITECT 1913 BONAIR DR SW , SEATTLE, WA, 98116 ALEXEEV CONSTRUCTION PO BOX 731152 , PUYALLUP, WA, 98373 ALEXECS934P9 CALWEST C/O KIDDER MATHEWS 631 STRANDER BLVD SUITE G , TUKWILA, WA, 98188 Phone: (206) 433-8997 Phone: (253) 230-4788 Expiration Date: 10/29/2015 DESCRIPTION OF WORK: REMOVE EXISTING FULL HEIGHT NON -BEARING DEMISING WALL. CONSTRUCT NEW FULL HEIGHT DEMISING WALL, CUT IN NEW 12' X 12' OPENING IN DEMISING WALL, CONSTRUCT NEW DRAFT CURTAIN AND OCCUPY SPACE FOR KOTIS Project Valuation: $52,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: IIIB Electrical Service Provided by: TUKWILA FIRE SERVICE Fees Collected: $1,712.06 Occupancy per IBC: S-1 Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2014 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: I I hearby certify that I have read and : ed this permit and know the same to be true and correct. All provisions of law and ordinances gove this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating con uction or the performance of work. I am authorized to sign and obtain this d ' attached to this permit. development permit and agree to Signature: Print Name: Date: (O .2� l 4 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8-feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 33: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 12: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 13: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 15: Maintain fire extinguisher coverage throughout. 16: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 17: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 18: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 19: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 20: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 21: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.6) 22: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 23: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1011.6.3) 24: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.3.1) 28: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 26: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 25: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 30: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 29: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 31: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 32: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 34: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 35: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 27: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 36: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 37: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0611 EMERGENCY LIGHTING 1400 FIRE FINAL 0409 FRAMING 0502 LATH & GYPSUM CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http: vv1vvv.iukvvila11.A.iov Building Permit No. b �'L(— 0 Project No. Date Application Accepted: r 0— �' 1 Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address:" ,CO9;> vt ,_ 2 ....`'1e' r ] Tenant Name: � exraftsw PROPERTY OWNER Name: castvti3.1,VI)140031 Address' m►uetz. 6Lm1_ Zip:co8° City:..151,4 State: wk CONTACT PERSON — person receiving all project communication �/�, Name:Y �4n 12641 Address:li Itio R*1302az og city:„ State . Zip:il6 Phone: A,,, . L36 q j•,citri'Fax: ft. Email:tKetikEG4heille4GA(Dm GENERAL CONTRACTOR INFORMATION Company Name: „s^ `�V Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: King Co Assessor's Tax No.: l'►61* 17'4' Floor: 1 New Tenant: ❑ Yes 74,,.No Suite Number: ARCHITECT OF RECORD Company Name:,2 64c %,.,_ _ _ i GrvA �j Architect Name: �lc4r/ �'�i Address: lQ to . kw la, 9y City ei t`1Y State Zip: a,8me Phone:/lwv_, .4 gt Fax: . W/0 ���'T $569 Email: ENGINEER OF RECORD Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: k ru 13, A" 4 Address: City: State: Zip: H:1ApplicatioI Worn -Applications On Line\2011 Applications \Remit Application Revised - 8-9-11.doa Revised: August 2011 bh Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ *LIM, Describe the scope of work (please provide detailed information): Existing Building Valuation: $ 1. oil Lual VOID*, : 5(wts4y,. FULL, I4E I4P i- go 4. t3r 414,E retPtiQi4c4 \Vow, ! Gut21.40 Fuu. 14641-11 OeMi,N144W4u:.1 Cot to LOW 1Z1 12 CiPeliwitt lit- Iitis144 Way., Co►ottaud1e►Y Awl-7 Citivtai I duoer64(74/AUE Co kvttg Will there be new rack storage? to Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC Ist Floor .39 aar, L� t 4 Ill• v3 sk 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling,, rovide the following: Lot Area (sq ft): Lk) urbuo Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard:P6 011141619 Compact: Handicap: Will there be a change in use? ❑ Yes 141,,No If "yes', explain: FIRE PROTECTION/HAZARDOUS MATERIALS: $....... Sprinklers Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety L1ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2011 Applications\Pemtit Application Revised - 8-9-11.doce Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGT.ON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW RIZED AGENT: Signature: `' Date: it I 14" Print Name: I 4U7. Nt1.6 Day Telephone: ' 43''3 4414 Mailing Address:'1,67tamale Piz H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised- 8.9-11.docx Revised: August 2011 bh tt(e VA• lll� City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT I QUANTITY I PAID PermitTRAK $66.50 D14-0318 Address: 1165 ANDOVER PARK W Apn: 3523049097 $66.50 DEVELOPMENT $66.50 ADDITIONAL PLAN REVIEW TOTAL FEES PAID BY RECEIPT: R6500 R000.345.830.00.00 1.00 $66.50 $66.50 Date Paid: Monday, October 26, 2015 Paid By: ADAN C GRANT Pay Method: CREDIT CARD 01445D Printed: Monday, October 26, 2015 2:50 PM 1 of 1 CP1_./ 1✓ SYSTEMS Cash Register Receipt City of Tukwila Receipt Number R3365 DESCRIPTIONS I ACCOUNT I QUANTITY PermitTRAK I PAID $1,059.17 D14-0318 Address: 1165 ANDOVER PARK W Apn: 3523049097 $1,059.17 DEVELOPMENT $1,008.95 PERMIT FEE R000.322.100.00.00 0.00 $1,004.45 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $50.22 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R3365 R000.322.900.04.00 0.00 $50.22 $1,059.17 Date Paid: Wednesday, October 22, 2014 Paid By: A C S LLC Pay Method: CREDIT CARD 022534 Printed: Wednesday, October 22, 2014 9:45 AM 1 of 1 CPWSYSTEMS DESCRIPTIONS PermitTRAK I ACCOUNT QUANTITY I PAID D14-0318 Address: 1165 ANDOVER PARK W Apn: 3523049097 $652.89 DEVELOPMENT $652.89 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R3207 R000.345.830.00.00 0.00 $652.89 $652.89 Date Paid: Wednesday, October 01, 2014 Paid By: DAVID KEHLE Pay Method: CREDIT CARD 035736 Printed: Wednesday, October 01, 2014 2:42 PM 1 of 1 SYSTEnAS INSPECTION RECORD I Retain a copy with permit a-V D( INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 4313 i%0PP-- Project: , , Icon 5 DeS/9/1-1 'Type of Insp on: c Addre/ / S ever f,?1, ate Cal ed7. Special Instructions: ,.-- Date Wanted:/ �. p.m. Requester: Phone No: �� (go 97 Approved per applicable codes, Corrections required prior to approval. COMMENTS: Firiz..-ALZ_ Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, feemust be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. cp INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431=3670 Permit Inspection Request Line (206) 438-9350 o3/' Project: \\ �- Kon5 1 1�v, / ,. Li pAivsi� �nCcu.I� Type f Inspectiohj C lt2 Address: //X 4 ti Ad6> Date Special Instructions: tsCIAIL ,() / 7�� Date Wanted: '7 30—/tom a.m. p.m. Reques r: Phone No: Z53 Zot 20(`/ ElApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: pcovLo ibkciulA Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of MI5: Address: WC Date Called: Special Instructions: ' Date Wanted: 1 ‘112011•1 ep P: • Requester: e I Phone No: 25 _ proved per applicable codes. Corrections required prior to approval. COMMENTS; Inspect;\ _ Date: —1/REINSFIiECTION FEE REQUIRED)Srior to next/ onspection. fee 4ust be • - i paid at/6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. paid / . INSPECTION NO. INSPECTION RECORD Retain a copy with permit olq-a18 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: f KCSTIC D StloP.! Type ofinspe tion: l iZi0trly 6 Address: � � 1 l � � Date Called: Special Instructions O}' NJ Date cyan i t ) t t 1 a� m? i ( p.m. Requester'- 1"E1 Phoo3- "1 3 3 ` qZ'-t 3 `t Approved per applicable codes. Corrections required prior to approval. COMMENTS: ins ectar:l Dec( REINS,PECTION FEE REQUIRED. Prior to n'xt inspection, fee must be paid,.t 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: I !! • (KoT+ S Type of Inspection: , C=4142C5 cirt ct►RJIA-L Address: %/ems it:‘P Suite #: Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: gq ✓= o S / ► i l .r n// a- OK-- 1 C4-7rwlorki roA La c..) I 1 6- t-tr l e /1 I f Ai-Pc-J.- S', J r Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 4. .c.- S Date: //7/// Hrs.:4/frt /,L,, v $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Address: Company Name: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 e) INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 1)16/- PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Type of Inspection: Address: /i 65- Suite #: fa_ 10 i,� Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: <-) P irJ1A-t- -`A?- i i0;4�- - I.)K -- 1. a 1%P `55 a ' \ i- 1 vet Ai _ P 4 P_A .0-e C - A Aid ! 'I"! e tU S / .P T'! `P"-74- .) gy } P-P foue /14-05 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Date: -7h S 7, c--`Hrs.: r $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Address: Company Name: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER el-'a3/ a PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Type Inspectio �•,. 4-e- A.J Address: )16 `7 ,A' Ai Suite #: Con ct Person: - Special Instructions: Phone No.: Approved per applicable codes. 'rrections required prior to approval. COMMENTS: 1 . d6 isd se At. Iv/,. cvoyi„ ue-rifi 1Vi ;' , 0v --_. PA.- o6 a` 7 - Li li D / Par !-g P -e t 1' (ALA Needs Shift Inspection: Serinklers: Fire Alarm: `, Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: /7r Sc Date: 2./ 21 i Hrs.: J $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance'Department: Call to schedule a reinspection. Billin Attn: 9 Address: Address Company Name: City: State: Zip: T.F.D. Form F.P. 113 Word/Inspection Record Form.Doc 3/14/14 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 R3 Envelope Summary ENV -SUM 2912 Washington State Energy Code Compliance Forms for Commercial. Group RI and a aretn, R2 & R3 Revised June 2013 Project Info Project Address kirc, 4NsiobJ ,e Date 10101114- I { (A' Ae2 at For Building �LE , at.. Department Use COPY Applicant Name: I2U 02 lik, I �wiiir Address: me ¢ 9! ftleV1 'flL t Applicant Phone: _Wco ,,eG 1* Project Description of OccupancylConditioning • New Building ■ Addition 44 Alteration ■ Change Compliance Path 0 Total Building Performance ■ Prescriptive ■ Component Performance Occupancy Group 0 Commercial 0 Group R (R-1 & > 3 story R-2 and R-3) Climate Zone • Climate Zone `-/ �✓ 0 Climate Zone (t ( See WSEC 301.1 for county list) Vertical Fenestration and Skylight Area Calculation If complying via the Prescriptive path, provide values for vertical fenestration, skylights, gross walls and roof. if complying via the Component Pe►fommance path, these values are auto- filled by the ENV-UA form and cannot be edited here. Total Vertical Gross Exterior Fenestration Above Grade % Vertical (rough opening) divided by Wall Area times 100 equals Fenestration �/ 1 �i� X 100 Gross Exterior Total Skylight divided by Roof Area times 100 equals % Skylight l lAt X 100 = Maximum Prescriptive Fenestration Area Vertical Fenestration REVIEWED FOP CODE COMPLIAN APPROVED OCT 15 2014 Skylights 50% Floor Area in DLZ 0 More than 50% of the floor area in daylight zone per C402.3.1.1 , Semi -Heated Path ❑ Project has semi -heated areas as defined per C402.1.4 and for requirements. other conditioned or Component City of Tukwila BUILDING DIVISi( • Applying wall exception to semi -heated areas 1. To be deemed semi -heated the area is heated but not cooled, output capacity between 3.4 - 8 Btuh/ft2. Refer to C402.1.4 2. Semi -heated spaces shall be documented separately from separate compliance forms for each conditioned area type. 3.Semi-heated spaces may comply under the Prescriptive path. 4.Envelope elements separating semi -heated from other conditioned thermal envelope requirements for an exterior wall. nas a max. neaung system spaces- provide Performance compliance spaces shall comply with Refrigerated Spaces freezer of Occupancy/Conditioning only. Compliance documentation for the ENV -PRESCRIPTIVE fora. Refer • Walk-in cooler 0 Walk-in • Refrigerated Warehouse Cooler • Change Refrigerated spaces shall comply under the Prescriptive Path these areas may be combined with non -refrigerated areas in Mixed Occupancy and/or Space Conditioning Project includes more than one occupancy type and/or level compliance forms may be required. Select all that apply to scope of space conditioning. Multiple of project: ❑ Refrigerated Space 0 Low Energy* RECEIVE[ CITY OF V K and compliance forms for nr+r n . ..,. [yl, Commercial ■ Group R1 or>3 story R2/R3 • Fully Conditioned ❑ Semi -Heated 0 Group R2/R3 < 3 story *Low energy areas are exempt from all thermal envelope provisions these areas are not required. Refer to C101.5.2 for exemption. dfliwiro filtit2'44 544"? biLl 03(8 E N ILA PERMIT CENTER 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Interior Lighting Summary LGT-SUM 012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Info Project Address. ( 1 , - ; Date cob l I Wq A4410,162 iil6i V6Ir For Building partment Use • 10 �j�'�},j.t e t Applicant Name: betide / t he Applicant Address: i jble,WPk �,\i r, dlr�'�► � v" Applicant Phone: n 4. Project Description Si Alteration • New Building ■ Addition • Plans Included Lighting Compliance Path 0 Lighting Power Density Calculations 0 Total Building Performance (If Total Building Performance then only LGT-CHK is required.) Interior Lighting Compliance Option 0 Building Area Method lJi Space -by -space Method Interior Lighting System Description Briefly describe lighting system type and features. ,�"" 140 C NC - kott/4¢ Additions and Change of Space Use (C101.4.3 & C101.4.4) • Addition area or Change of Space Use area complies with all applicable provisions as stand alone project area or Change of Space Use area is combined with existing building lighting systems to demonstrate with all applicable provisions Building Area Method (LTG-iNT-BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum and proposed (including existing if applicable) lighting wattage of Addition or Change of Use scope. Provide applicable lighting per C405.2 and commissioning of lighting controls per C405.13. 2 Addition compliance Provide allowed controls Alterations, Renovations and Repairs (C101.4.3.1) • 60% or more of luminaires in space replaced Building Area Method (LTG-INT-BLD) or Space -By -Space Method (LTG-iNT-SPACE) Compliance Fonn. Document maximum and proposed (including existing) lighting wattage of project scope Provide allowed 60% of luminaires in space replaced Space -by -space Method (LTG-INT-SPACE) Compliance Fonn. Document existing total wattage in space and proposed existing) lighting wattage of project scope • Less than Provide (including 0 Lamp and/or ballast replacement within existing luminaires only — existing total interior building wattage not increased installed to serve added fixtures and/or fixtures relocated to new circuit applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific controls (C405.2.3), and commissioning of lighting controls per C40513 • New wiring Provide application • New or moved lighting panel all applicable lighting controls as noted for New Wiring, automatic time switch controls (C405.2.2.1), and commissioning of controls per C405.13. Provide lighting reconfigured - luminaires unchanged or moved only all applicable lighting controls as noted for New wring and commissioning of lighting controls per C405.13. • Space is Provide -i No changes are being made to the interior lighting and space use not changed. City of Tukwila Department of Community Development 12/1/2015 DAVID KEHLE, ARCHITECT 1913 BONAIR DR SW SEATTLE, WA 98116 RE: Permit No. D14-0318 KOTIS DESIGN EXPANSION 1165 ANDOVER PARK W Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 1/26/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 1/26/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, I/ \Pp Rachelle Ripley Permit Technician File No: D14-0318 6300 Southcenter Boulevard Suite 11100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 davide arc tec September 24, 2015 City of Tukwila Building Division 6300 Southcenter Blvd. Suite 100 Tukwila, Washington 98188 Attn: Mr. Dave Larsen Kotis Design Re: Permit #D14-0318 Dear Dave, Kotis Design wants to move the exit pathway in the middle of their expansion from the South side of the old demising wall to the North side of the old demising wall. The exit illumination will be located at the new exit pathway as noted on the original permit. Adam Grant evidently tried to get it moved in the field and at the counter, but was told I needed to resubmit. I have flagged the change as rev 1 and clouded the area of change. I trust these will suffice for the revised permit. If you have any questions, please call. Since David Kehle DK/dk Cc: Adam Grant 0225km/cityletkotis09-24-15 1916 Bonair Drive S.W. Seattle, WA 98116 1:,VIS8ONY0a. D14- MB (206) 433-8997 fax (206) 246-8369 email: dkehle@dkehlearch.com City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director April 16, 2015 Andrea Hacker Kidder Mathews 631 Strander Blvd, Suite G Tukwila, WA 98188 RE: Request for Extension Permit Number D14-0318 Dear Ms. Hacker, This letter is in response to your written request for an extension to D14-0318. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit for an additional 180 days, through November 19, 2015. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, Bill Rambo Permit Technician File: Permit No. D14-0318 W:\Permit Center\Extension Letters\Permits\2014\D14-0318 Permit Extension #1.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 April 14, 2015 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 RE: Permit No. D14-0318 Kotis Design Expansion 1165 Andover Park W. To Whom It May Concern: mac' Kidder 1 Mathews RECEIVED APR152015 DV� O11A41 NT The purpose of this letter is to request an extension on the above referenced permit number. The work has been started, however additional fire and life safety work is required and has delayed the process due to the Landlords bidding requirements. The work is now anticipated to be complete by June 15th and we will call for final inspection prior to this date. Please contact me using the information on this letterhead should you have any questions. Sincerely, Andrea Hacker Property Manager Kidder Mathews Request for Extension # L Current Expiration Date: 5,1q-15-- `Ex, tension Request: LJ Approved for / g(] days Denied (provide explanation) Signature/Initials ACCREDITED fo; MANAGEMENT ..4" ORGANIZATION® 631 Strander Blvd, Suite G Tukwila, WA 98188 T 206.575.0765 F 206.575.0721 kiddermathews.com City of Tukwila Department of Community Development 4/1/2015 DAVID KEHLE, ARCHITECT 1913 BONAIR DR SW SEATTLE, WA 98116 RE: Permit No. D14-0318 KOTIS DESIGN EXPANSION 1165 ANDOVER PARK W Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 5/19/2015. Based on the above, you are hereby advised to: 1) Ca11 the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 5/19/2015, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D14-0318 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0318 DATE: 10/09/15 PROJECT NAME: KOTIS DESIGN SITE ADDRESS: 1165 ANDOVER PARK W Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # X Revision # 1 after Permit Issued DEPARTMENTS: Aw 10 \ Building Division Public Works 5 \b\(ejt9 tow Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 10/15/2015 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/12/2015 Approved Corrections Required n Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping 0 PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPS PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0318 DATE: 10/01/14 PROJECT NAME: KO-T-IS- DESIGN -EXPANSION SITE ADDRESS: 1165 ANDOVER PARK W X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division in N// Public Works p-M 4uc1 c0-10,114 Fire Prevention Structural ctL ite Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 10/02/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/30/14 Approved Corrections Required El (corrections entered in Reviews) Notation: Approved with Conditions Denied (ie: Zoning Issues) n n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PROJECT NAME: SITE ADDRESS: DI II�%v8.w Qle PERMIT NO: ID 14-05E13 ORIGINAL ISSUE DATE: REVISION LOG REVISION NO. DATE RECEIVED STAFF INIT S ISSUED DATE STAFF INITIALS I to-a-�5 t0-149-c " 1.4,0 Summary of Revision: 'A't l p ail i-e1% (4-A, in Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: i)14-- (3)`� ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # ( after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: Contact Perso k7 V iePok- Phone Number:" G2 , " Summary of Revision: (9,e Otcr ?ARO/ G . rcEIVED 1,svIliftp OCT 0 9 281E Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: dEntered in TRAKiT on I 0 " ALEXEEV CONSTRUCTION SVrg LLC Page 1 of 2 4:74:, Washington State Departrnent of Labor & Industries ALEXEEV CONSTRUCTION SVCS LLC Owner or tradesperson ALEXEEV, ALEXANDR A Principals ALEXEEV, ALEXANDR A, MANAGER ALYEKSYEYEV, OLEKSANDR, PARTNER/MEMBER (End: 10/14/2013) Doing business as ALEXEEV CONSTRUCTION SVCS LLC WA UBI No. 602 767 386 PO BOX 731152 PUYALLUP, WA98373 253-230-4788 PIERCE County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. ALEXECS934P9 Effective — expiration 10/29/2007-10/29/2015 Bond CBIC Bond account no. SF2145 Received by L&I 10/29/2007 Insurance Ohio Security Ins Co Policy no. BKS53146520 Received by L&I 10/13/2014 $12,000.00 Effective date 10/22/2007 Expiration date Until Canceled $1,000,000.00 Effective date 11/16/2013 Expiration date https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602767386&LIC=ALEXECS934P9&SAW= 10/22/2014 11 ■ ■ ■ ■ 1M INTERLINE NO CI-IA4NGES ■ ■ ■ ■ ■ ■ 1 EX. OFFICE NO C DRIVE It. v IRR fj EX. WAREHOUSE DOCK HIGH DOCK HIGH AREA OF EXP4NION FOR KOTIS I21'-3" S QT51'03" W 797.00' — EX. EXIt PATHWAY WITH EMERGENCY LIGHT! EXISTING SHEAR 11141\ N1/4 TO REMAIN 1111 CHAMP4 NO CHANGES ■ p. --11 11 _ I I I I I I I I I I I I I I I I III I I I I I I I I -- ".�-•� _--- --_ --� --t'�- _-�—�-�--r.-yy....-- r--ti�.....� r—t1----..r.1 *---_-}I---_ tf-.n-.-_ --- -ow.- �. _ -id— _— r--,y- 1 I .........- -- -�- -' _' ..�.- -- LJ Ll !.J Ll l.J LLJ 11 �1�iJ L.! LJ y O \ EX STUD WALL, TRIM A5 NEEDED EX WALL FULL HEIGHT STUD WALL (PLYWOOD ES) ADD FALL HEIGHT STUDS AT JAME, (MIN 2 REQUIRED) ADD 5/8" DIA X 4" tITEN-HD AT END EXISTING PLATE —\ EXISTING SILL PLATE TRIM AS REM EX SLAB ELEVATION OF NEW OPENING SCALE: 1/4" = 1'-0" NAIL EXISTING PLYWOOD TO NEW STUDS AND 6X6 HEADER WITH UIdcotiloN AT 3" Q.C. 11 ■ DOCK HIGH s . i .NEW EXIT PATHWAY iWTH EMEI ENCY LIGHTING DOCK HIGH EXISTING ELECTRICAL Attoroir a/1- N -CONSTRUCT NEW DEMISING WALL XI EX. WARHOUSE ■ 11691`1$11 KOTIS - ...-..r- 01.1.- I 169 'T18 DOOR I/S� OAKlAr' SIC ON = DE c1 DOOR « LF COM"ION PAW OF TRAVEL TO EXIT PANAY a i i ■ EX. OFFICES NO cH4NGE X�IILA X�I OVE EASING DEMISING WALL EX. WAREHOUSE ■ 1161 NEUJ KOTE5 DOCK HIGH ■ ■ I DRIVE IN POCK HIGH DRIVE IN EXISTING SHEAR WALL TO REMAIN _. L... —_.- — _I�__—_.[1,.__—, — — .. _ — _ _ it — r — • 0 NORTH I Fx71 IEX. EXITPATHWAY WITH EMERGENCY LIGHTING EX .WAREHOUSE RI:MovE PORTION SHEAR FOR OPENING NEW 12'XI2' i i 165 EXISTING KOTIS l cHANGES ■ ono 0 �I•I II II I:I T_II II II �'II �_ II II _ FLOOR PLAN: KOTIS EXF4NSION SCALE: vie°,11-0" REV 09.15.14 1165 REVISIONS -, No changes shall hn r,c,drto the scope of work without pr;cr P p )rov t nt Thkw!l • • • • rff '_.i if`ri•^.f lra: .lU� C.i.''trl{:n i�r�')f ,:f; NOTE: EMERGENCY .LIGHTING. FACILITIES SHALL 13E .ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT I$ AT LEAST AN AVERAGE OF 1 FOOT-CANDLE AND A MINIMUM AT ANY .POINT QF 0.1 FOOT-CANDLE MEASURED ALONG TIE PATH OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS $1-IA,LL 1BE PERMITED TO DECLINE TO 0.6 FOOT-CANDLE AVERAGE AND A MINIMUM AT ANY POINT OF 0.0(0 FOOT-CANDLE AT THE END OF NE EMERCx4NCY LIGHTING TIME DURATION. A MAXIMUM -TO -MINIMUM ILLUMINATION UNIFORMITY RATIO OF 40 TO 1 SMALL NOT 5E EXCEEDED. FILE C3L Y • Permit No. l) 1- 066 Plan review approval is subject to errors an Approval et construction documents does r,e,, au tiorzo the violation of any adopted code or ordinance. Receipt of approved Field/opy id corer s is acknowledgod: 0225 GVA W 0 a 09-29-14 DESCRIPTION O CO SF'')APe"f ;� )21 Mechanical 12'Electricat ,Er Plumbing ,E1 Gas Piping C: f oafTuk��.fila By: Date: City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 0 9 2015 PERMIT CENTER VI$ION N01_ I 4 W H c74) 0 z E-4 w Cn H H 0 0 SOUTHCENTER 'S O c0 vfyw 1- z M� 0 oo (o‹ -(r)O) 0 REVIEVNE) FOR CODE CON'LIANCE APPRC iED OCT 21 201 • P1J City ofT kwila BUI�,OING DIVISION C:1Documents and Settings\Ali Users\Dacuments\CAD\200210225 GVA-KM\Southcenter West Business Park\KOTIS DESIGN 1165WEW EXPANSION\T-2 rev pathway 09-23-15.dwg, T-2 REV 10-09-15,10/81201511:30:14 AM MIXED —USE, NON-5EP4Ra4TED USES (SECTION 501): IBUILDING AND SITE STATISTICS: SCOPE OF WORK: ENERGY CODE TYPE OF CONSTRUCTION: III-5 (FULLY SPRINKLED) 5013 TWO STORY. 6UILDINCs IS SURROUNDED BY 60' OPEN SPACE ALL SIDES. (13,01 USES) ASSE55OR PARCEL NUMBER 943295114 LEGAL DESCRIPTION PARCEL B: 352304 91 POR CF SW 1/4 OF SE 1/4 OF SEC 26-23-4 4 POR NW 1/4 OF NE 1/4 OF SEC 35-23-4 BEG AT NE COR OF NW 1/4 OF NE 1/4 SEC 35 TH N 81-44-08 W 30 FT TH N I-41-29 E ALG W LN aF ANDOVER PARK W 115.66 FT TH N 81-55-02 W 110.1 FT TO TP08 TH S 81-55-02 E 440.1 Ft TH 8 1-41-29 W 114.81 FT TO AN ANGLE PT THEREIN TH S 1-51-39 W 682.19 FT TH N 81-55-02 W 440.1 FT TH NLY IN A STRAIGHT LN 191 FT TO TPOB LESS WLY 216b FT \\\ 2 CZ E--1 Ly f— EXISTING TENANT SPACE NO WORK BUILDING CODE: ZONING: SITE AREA: APPROX. EXISTING BLDG. (OFFICE 10;918, 111145E 85,232) TENANT SPACE: OFFICE: AREA OF WORK: IBC 2012 W/ WA STATE AMENDMENTS TUC (TUKWILA URBAN CENTER) 215,015 SF. (4.94 AC) 95,850 SF. son SF. 1,140 SF. 2,600 SR OCCUPANCY GIWUPS AND LOADS: B (OFFICE) 1,140 SR / 100 • 11 OCCUPANTS 5-1 (UAREHOUSE) 14b6i1 SF / 500 • 29 OCCUPANTS TOTAL OCCUPANTS • 40 OCCUPANTS TYPE OF CONSTRUCTION: III-B (FULLY SPRINKLED) PARKING REQUIRED PARKING :OVERALL BUILDING OFFICE: 8,318.4 SF. a 3.0/1000 : 25.0 SPACES RETAIL: 14,641.0 SF. a 2.5/1000 : 36.6 SPACES WHSE: 83,555.6 SF. a 1.012000 : 41.8 SPACES 103 SPACES PARKING SPACES PROVIDED 125 EXISTING PARKING SPACES (NO CHANGE) PLANNING APPROVED . No changes can be madeto these plans without approval from the Planning Division of DCD Approved By: C' ) Date: 10 -1—t NEW DEMISING WALL EXISTING TENANT SPACE NO WORK e — —1— — — —U— — AIUPS RC REMOVE EXISTING NON -BEARING RILL HEIGHT DEMISING LUAU., CONSTRUCT NEW RILL FIGHT NON -BEARING DEMISNG WALL, CONSTtaICT NEW DRAFT CURTAIN, CUT IN NEW 121X12' OENING IN SHEAR WAIL, AND OCR FOR KOTIS. SOKE VENTS WILL BE A SEPARATE PERMIT AS WELL AS RACK BY lENAN1. 5EPER4TE PERMITS PLUMBING, ELECTRICAL, HVAC, SMOKE VENTS, AND SPRINKLER ARE UNDER SEPERATE PERMITS. OWNER CALMEST INDUSTRIAL HOLDINGS LLC C/O KIDDER MATHEWS 631 STRANDER BLVD., SUITE G TUKWILA, WA 98188 PH: 253-893-1156 FX: 206-515-0121 AREAS OF WORK REMOVE EXISTING DEMISING WALL —41---11--fi---fl--fF-- TENANT AfREA 16 EXPANSION KOTIS SITE FLAN SCALE: i" = 30' SEPARATE PERMIT REQUIRED FOR: IMechanicai ,Electrical iumbing Was Piping City of Tukwila BUILDING DIVISION FILE COPY Penttt No. 18 Plan review approval Is sum to errors Approval of construction documents omissions, docu does not authorize the violation of any adopted • • is or ordinance. Receipt of approved Field +1and is acknowle dged: 8y: Date: City of Tukwila BUILDING DIVISION rNREVISIONS o changes shall be made to the scope of work without prior approval of 1 l Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 8 01'5iO3' W 797.00' NO CHANGES TO BUILDING ENVELOPE NO CHANGES TO DOING LIGHTING. SOUTH 1SDTH STREET i VICINITY MAP SCALE N.T.S. BLDG E BLDG BLDG C BUILDING A ANDOVER PARK WEST ry KEY SITE PLAN SCALE: N.T.S. EXISTING TENANT SPACE NO WORK TENANT AREA 21 EXISTING KOTIS 0 EXISTING TENANT SPACE NO WORK REVIEWED FOR ODE COMPLIANCE APPROVED OCT i 7 2014 City of Tukwila BUILDING DIVISION p Q z Q E RECEIVED TV OF TUKWILA OCT . 01 2014 .RMIT CENTER 0225 GV,4 w 2 DESCRIPTION 0 o(0 0 0 N N A PROPOSED TENANT IMPROVEMENT FOR: KOTIS DESIGN EXPANSION ST BUSINESS PARK SOUTHCENTER PARK WEST, O co 0 0_' 1rcn < z O - a J i— co (0 Q (3)W 0 =1 C:\Documents and Settings\AII Users\Documents\CAD\2002\0225 GVA-KM\Southcenter West Business Park\KOTIS DESIGN 1165\NEW EXPANSION\SD-1_T-1 ADD EXIT.dwg, ; ,, .n,� „MA„-. IL.,U.IN/ , lVI TYPICAL WALL FRAMING ATTACH BOTTOM TRACK TO CONC. FLOOR W/ POWDER DRIVEN ANCHORS, HILTI OR APPROVED I" EMBEDMENT AT 24" O.. UJ4LL TO 514E SCALE: 1-1/2" • 1'-0" 5/8" GYP. BD. CONC. SLAB ON GRADE + 1/2" SPACE GYP.BD. TO GYP. P. EA. SIDE ROOF STRUCTURE .11111010 HEAP DETAIL Den:ECT ION 6' DEEP LEG TRACK ATTACH TO G.L$. W/3 - 15/8" SCREWS a 2'-0" O:C. (DEEP LEG IS 3") STUDS PER SCHEDULE. 2'-0" O.C. NOT ATTACHED TO TRACK BUT LAPPED UP INSIDE 1". GYP.BD. ATTACHED TO STUD -NOT TO GLB OR TRACK- LAP 1 I/2" ON GLB SECTION GYP. BD JAM DETAIL SCALE: 1-1/2" . 1'-0" RAFT CURTAIN SCALE:3/4' • I'-0" 5/8" GYP BD. WRAP Ul/ MTL CORNERS 5/8" GYP BD. EACH SIDE BUILT UP ROOFING OVER PLYWOOD OF STRUCTURE FRAMING 1/2" GYP. BD. DRAFT CURTAIN FIRE TAPE ONLY - STEEL STUDS ALONG TOP AND BOTTOM EDGE (25 GA) 3 1/2" STEEL STUD BRACE AT 10' O.C. CONNECT TO BOTTOM TRACK AND PURLINS, STIFFENERS OR BEAMS AS REQUIRED SECTION SECTION DOUBLE DOME INSULATED SKYLIGHT/SMOKEVENT (U : 0.5e UJ/ INSULATED CURBING r SKYLIGHT CURB J SCALE 3/4" _ 11-0" RUN ROOFING UP AND OVER CANT AND CURB, COUNTER FLASH OVER ROOFING. MAKE WEATHER TIGHT. EX. RIGID INSULATION OVER PLYWOOD ROOF STRUCTURE ■ V V E15 ■ I X I V_ CONSTRUCT NEW RILL HEIGHT NON BEARING DEMISING WALL (WALL TYPE 24'-4" �a EX. RAMP IEXIT EX. OFFICES NO CHANGES 1,140 SF Jo ■ REMOVE EXISTING NON BEARING AND NON SHEAR FULL. HEIGHT DEMISING WALL PATCH FLOOR AND ROOF AS REQUIRED X� CONSTRUCT NEW CURTAIN WALL ON SIDE OF GLU LAM BEAM (SEE DETAIL 4/T-1) 123'-6" v EXISTING WAREHOUSE AND MANUFACTURING ■ 14,611 5F+I/500: 30 OCC. TWO EXIT DUE TO TRAVEL DISTANCES INSTALL 6 NEW SMOKE VENTS IN EXISTING ROOF, BY TENANT UNDER SEPARATE PERMIT ICE IXI ILA V EET I X I XI ■ • V V 0 EXISTING WAREHOUSE AND MANUFACTURING I4,S38 SFe1/500: 30 OCC. TWO EXIT DUE TO RACKS NO WORK IN WAREHOUSE CUT IN NEW I2'X12' OPENING IN AN EXISTING SHEAR WALL, SEE ELEVATION OF BOOR ING 1-1 0(4 r-, Jy d10 4%IL&S i S 14tar G„'"' SEE ELEVATION T-2 ■ FX II V. EX. DRAFT CURTAIN TO REMAI r ■ L—J EXISTING SMOKE VENTS IN EXISTING ROOF, XV. --- ---- --- I1 11 6,321 SF HIGH e100. 63 SF 32 SF•36SF 122' 124' ����� Q-----n-- _ �======__== __= __==_= ===za=-1- -ti I11 11 I•I 11 �II II • 11 11 II-------tr-------ri-- --- r_-m_—_11___________5r=__ __—tr______tr= PILED STOR 8,5SFHIC OF VENT, 3 AT 6100 • 84 SF OF VENT, 3 AT 32 SF•96SF SEPARATE STORAGE RACK PERMIT REQUIRED All rack storage fixtures over 5'-9" high shall be installed under the provisions of a separate storage rack building permit. All rack storage fixtures greater than 8-feet high shall have the method of anchorage/bracing designed by a professional engineer. Periodic special inspection is required in all cases during the anchorage of racks over 8-feet in height. Special inspection requirements shall be specified on the rack permit plan. NORTH OVERALL FLOOR PLAN: KOTIS EXPANSION DOOR SCHEDULE: E1,2,3 EX. 3'Xl' STOREFRONT ENTRY DOOR, PADDLE EXIT E2,5,6,1 EX. 3'Xl' H. MTL DOOR AND JAMB, LOCKSET (ISNIDE E8,S,11, EX. 8'X10' DOCK HIGH DOORS 13-16 E10,12 EX. 10'X12' DRIVE IN DOORS E11-21 EX. 3'X1' SC WOOD DOOR AND WOOD JAMB, LOCKSET 24-21 22,23 EX. 3'Xl' SC WOOD DOOR AND WOOD JAMB, PRIVACY 26,28 WALL SC1-1EULE: REVIEWED FOR CODE COMPLIANCE APPROVED OCT 15 2014 City of Tukwila BUILDING DIVISION HANDLE TURNS FREELY TO EXIT) OR LATCHSET LOCK RECEIVED CITY OF TUKWILA OCT 012014 PERMIT CENTER A NEW 6" X 18 GA. STEEL STUD AT 24" O.C. TO GLU LAM ABOVE, WITH 5/8" GYP BD EACH SIDE, AND HEAD DEFLECTION TRACK 0225 GVA U w 0 a a 3 w w 0 0 0 0 z 0 n. it 0 W 0 3 u1 } w 0 lY 0 u- m tp 0_ lY 0 u- 1' 61 61 A PROPOSED TENANT IMPROVEMENT FOR: KOTIS DESIGN EXPANSION ST BUSINESS SOUTHCENTER =1 0 C:\Documents and Settings\All Users\Documents\CAD\200210225 GVA-KM\Southcenter West Business Park\KOTIS DESIGN 11651NEW EXPANSION\SD-1 T-1 ADD EXIT.dwg(, ., ,-, .,...,, . , ._,.,.-, ,-, , ■ . . 11MM INTERLINE NO CII,ANGES . EX. OFFICE NO CHANGI DRIVE IN v RR RR EX. WAREHOUSE . DOCK HIGH DOCK HIGH V V V aroma OF XP4NSION FOR KOTIS I22'-3" `- EX. EXIT PATHWAY EME WITH RGENCY LIGHT( EXISTING SHEAR WA1 TO REMAIN `� 1111 CHAMF4 NO CHANGES . ----4L-----17-----A----A-----171-----A----A-----r7-----A----p- -_A---.-__.----- 11 mo__---._.._tr.---.-tr.--------------ti----------d----n-------------e- II--,.r----�-r 1111 ATO EX. SLAB II II II II II II II II II I1 11 I1 EX. STIR WALL, TRIM AS NEEDED EX. WALL FULL HEIGHT STUD WALL (PLYWOOD ES) ADD FULL HEIGHT STUDS AT JAMB (MIN 2 REQUIRED) ADD 5/8" DIA X 4" TITEN-HD AT END EXISTING PLATE EXISTING SILL PLATE TRIM AS REQU D If ®LEV4T1ON OF NEUJ OPENING SCALE: 1/4" = 1'-0" NAIL EXISTING PLYWOOD TO NEW STUDS AND 6X6 HEADER WITH 10dCONMON AT 3" O:C. . DOCK HIGH 211 NEW EXIT PATHWA• WITH EMERGENCY LIGHTING DOCK HIGH IXI 1y CONSTRUCT NEW DEMISING WALL EX. WAREHOUSE . i I I I 1169 NEUJ KO?If EXISTING ELECTRICAL DOCK HIGH DRIVE I S 01°51'03" W 797.00' DOCK HIGH DRIVE IN EX. OFFICES NO CHANGE . REMOVE EXISTING DEMISING WALL IxE EX. WAREHOUSE . 1161 NEUJ KOTIS X�I V. • 'r i \ \ I EXISTING SHEAR WALL I FX-I TO REMAIN V. IWITH EMERGENCY LIGHTM EX. EXIT PATHWAY DOCK HIGH . EX. WAREHOUSE . tt5 EXISTING KOTIS 1 CHANGES PORTION SHEAR FOR OPENING NEW I2'XI2' I . . 00 ----�----—_fl_ — II __ II II 1169 II 13 Io LF COMM PATH OF TRAVEL TO EXIT PATHWAY I 11 11 I1 II --t-----u---------d-----�,--- NORtN = = = = = = ======= =_= __= = = = =_• 1.1 11 II II 1I II II II 11 1I --I === =__= =_= ,=_==tF=_= ===—tp=__===tp==_ =_. 0 1165 21 FLOOR PLAN: KOTIS EXPANSION SCALE: 1/16"=1'-0" REv 09-15-14 NOTE: EMERGENCY LIGHTING FACILITIES SHALL 5E ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS AT LEAST AN AVERAGE OF 1 FOOT-CANDLE AND A MINIMUM AT ANY POINT OF 0.1 FOOT-CANDLE MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS SHALL 5E PERMITED TO DECLINE TO 0.6 FOOT-CANDLE AVERAGE AND A MINIMUM AT ANY POINT OF 0.06 FOOT-CANDLE AT THE END OF THE EMERGANCY LIGHTING TIME DURATION. A MAXIMUM -TO -MINIMUM ILLUMINATION UNIFORMITY RATIO OF 40 TO 1 SHALL NOT BE EXCEEDED. REVIEWED FOR CODE COMPLIANCE APPROVED OCT 15 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT . 01 2014 PERMIT CENTER 022r✓- CVA 0 a co DESCRIPTION H N N 0 0 A PROPOSED TENANT IMPROVEMENT FOR: KOTIS DESIGN EXPANSION <4 a ST BUSINESS S 0 UTHC ENTER PARK WEST, C:\Documents and Settings\All Users\Documents\CAD\2002\0225 GVA-KM\Southcenter West Business Park\KOTIS DESIGN 1165\NEW EXPANSION\SD-1 T-1 ADD EXIT.dwg, T-2 REV 09-15-14, 10/1/2014 12:10: PM