Loading...
HomeMy WebLinkAboutPermit D14-0321 - YITA LLC - STORAGE RACKSVITA LLC 1071 ANDOVER PARK E D14-0321 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 2623049106 1071 ANDOVER PARK E Project Name: YITA LLC DEVELOPMENT PERMIT Permit Number: D14-0321 Issue Date: 11/19/2014 Permit Expires On: 5/18/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: CBRE INC 20415 72ND AVE S #210 C/O STOCKBRIDGE CAPITAL GP, KENT, WA, 98032 MIKE SORENSON 1100 SW 7TH ST, RENTON, WA, 98057 NORTH WEST HANDLING SYSTEMS IN 1100 S.W. 7TH STEET, RENTON, WA, 98055 NORTHWH275JF SELF FUNDED BY YITA LLC Phone: (206) 818-4488 Phone: (206) 255-0500 Expiration Date: 10/9/2015 DESCRIPTION OF WORK: SUPPLY & INSTALL NEW AND USED RACKING. Project Valuation: $3,500.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: Type of Construction: Electrical Service Provided by: TUKWILA FIRE SERVICE Fees Collected: $291.30 Occupancy per IBC: Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2014 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: /7//,//7 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: c� // Print Name: GGP Date: (/ �✓ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 19: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 9: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 6: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 7: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 8: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 10: Maintain fire extinguisher coverage throughout. 13: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 12: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 14: Clearance between ignition sources, such as light fixtures, heaters and flame -producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 15: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.3.1) 16: Flue spaces shall be provided in accordance with International Fire Code Table 3208.3. Required flue spaces shall be maintained. 11: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 17: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 18: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 4046 SI-EPDXY/EXP CONC CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. -a)/ Qrd Project No. / Date Application Accepted: /Q /3 [ / 'i Date Application Expires: ('C((3//S (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: f � 7/ i5 d vL+r fl k . C Tenant Name: y , PROPERTY OWNER Name: G B R C— Address: a oilis 7ii S Si 712 9-1 v City: Kt A l..., State: w, ZipIs63 a CONTACT PERSON — person receiving all project communication` Name:io C reo_ 50 f) ./" 6 I k ,J0 Address: / 1 b 0 SW 7 . - City: tt� n State::t,4 Zip:9 57 Phone: a06.gig. l t W Fax: 7c/ i, i7' r ,�, [�„ 61 yj Email: W150('8nr0(#► € /2 L✓N.S,6Qr GENERAL CONTRACTOR INFORMATION Company Name:, ! ritit „ /es / ni! J (c�) ets �.. Address: 1(00 ✓ riiisy. City: 3a....4.State / , „4 G Zip:e p6�.7 «r\ l/� Phone: it 2,5-, a '05._66' Fax: y.eis., aa� 6ci,v� Contr RegNo. Exp ,etlOt'f G�w�t a7S� Date: /o%j' l S Tukwila Business License No.: 13,u S „ bet 9304 -1 King Co Assessor's Tax No.: Suite Number: ----' Floor: / New Tenant: Yes El _No RCHITECT OF RECORD Com Name: Architect Na Address: City: State: Zip: Phone: Fax: Em'. ENGINEER OF RECORD Company Name> Engineer Name: /`4 ©4 6 Address: W. .7 ;Ia.do ��V/. IprO City: C fa State:C4 Zip:/�4/ Phone: ga,02.yd... (0 Faxg,g_pia 3(f,/3 Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: cz_irc . k ki ��_ 10 Address: / i City: State: Zip: H:\Applications\Forms-Applications 0n Line\2011 Applications\Permit Application Revised - 8-9-I1.docx Revised: August 2011 bh Page 1 of 4 BUILDING PERMIT INFORMATION'— 206-431-3670 Valuation of Project (contractor's bid price): $ 31 G Describe the scope of work (please provide detailed information): Existing Building Valuation: $ cu pr f 1154 f /1 k AGf i €A (a ckt ,• P(24i€ 4l talc!' of ro..t✓r /l� e•y► � �rwj, k- S�P�(ett f >' l a it lx�.lJ., retckt,1' c0MM®AQt / r Will there be new rack storage? arCes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor 3 oao !ate 2nd Floor 1 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck 1 PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ' ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ��No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications''orms-Applications On Line \2011 Applications Permit Application Revised - 8.9.11.docx Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A13 I61t1ZED AGENT: Signature: Print Name: Mailing Address: ( 063 Slf/ 7 Date: 9/?'� Day Telephone: C6 R 1(11S7 Y City W, Zr9os7 State Zip H:\ApplicationsWorms-Applications On Linet2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PermitTRAK I PAID $291.30 D14-0321 Address: 1071 ANDOVER PARK E Apn: 2623049106 $291.30 DEVELOPMENT $282.86 PERMIT FEE R000.322.100.00.00 0.00 $168.70 PLAN CHECK FEE R000.345.830.00.00 0.00 $109.66 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $8.44 TECHNOLOGY FEE R000.322.900.04.00 0.00 TOTAL FEES PAID BY RECEIPT: R3224 $8.44 $291.30 Date Paid: Friday, October 03, 2014 Paid By: MICHAEL J SORENSON Pay Method: CREDIT CARD 015696 Printed: Friday, October 03, 2014 1:16 PM 1 of 1 C(SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO, PERMIT NO. Di Li -0 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 .91 Project 1 l -r A LI— Type of,tpspection: Address; to-7 1 AN144,t6Y P t.-- Date Date Called: ...„... Special Instructions: Date Wanted: 12 -1-1- 1 Li La,m. pm. 'Requester: 'Phone No: SApproved per applicable codes. Corrections required prior to approval. COMMENTS: r \ — 1 , A ---- See -C ,,,J A \ 1-e .-i- \r, ( (, 1 I , 7 ----, Int pectOr: Date: i v9-1 ‘1 1k-AA, _ - I Fr REI SPECTION FEE REQUIRED. Prior to next inspection. fee must be piid at 6300 Southcenter Blvd\ Suite 100. Call to schedule reinspection \./ i INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Type of Inspection: Address: Suite#: /67( �� f'(i' Contact Person: Special Instructions: Phone No.: 0(1 Approved per applicable codes. Corrections required prior to approval. COMMENTS: /4VC:: Ass - Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: A97 2) Date: / Z/. f / /( Hrs.: / . G $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Fireproofing Aggregates Shotcrete Concrete Masonry Asphalt Roofing P iling S teel S oils Wood December 1, 2014 File No. 14-677 Building Official City of Tukwila Building Department 6300 Southcenter Blvd., #100 Tukwila, WA 98188 Project: Address: Permit: Yita, LLC 1071 Andover Park E. D14-0321 A.A.R. TESTING LABORATORY, INC. CONSTRUCTION INSPECTIO"I AND MATERV.L TE£TI' 6 NATIONALLY ACCEPTED LABORATORY CITY OF rfv`�L' DEC 0 3 ?014 PERMIT CENTER This is to advise you that special inspections are completed on the above referenced project. The following inspection was required and a copy of our inspection report has already been forwarded to you. 1. Proprietary anchor bolt installation To the best of our knowledge all work inspected conformed to Tukwila Building Department approved plans, specifications, IBC and related codes and/or verbal or written instructions from the Engineer of Record. Sincerely, A.A.R. TESTING LABORATORY, INC. ald&tc&x Kimberle Anderson President CC: NorthWest Handling Systems, Inc. -Tony Johnson, Mike Sorenson Tel: (425) 881-5812 Fax (425) 881-5441 0 7126 180th Ave. NE o P.O. Box 2523 • Redmond, WA 98073 Client: NorthWest Handling Systems, Inc. 1100 SW 7th St. Renton, WA 98055-2939 Contact: Tony Johnson Field Report ta'EgWeOfiRgM Report #: 060686 Project Number: 14-677 Permit#: D14 0321 y' Project Name: Yita, LLC Address: 1071 Andover Park E. Inspection Performed: Proprietary Anchors Date: 11/19/2014 Time: Temperature: Anchor bolts for pallet racks. Verified installation of Hilti KBTZ anchors 1/2 x 4 1/2" with 3 1/4" embed, torqued to 40 ft./lbs. All placed per plan. Distribution: CITY of TUKWI LA DEC 0 3 2014 PERMIT CENTER E3 Distribute Client ❑ Distribute Contractor O Distribute Engineer ❑ Distribute Owner ® Distribute Municipality ❑ Distribute Other O Distribute Architect ❑ Distribute Other Inspector: Trow, Michael Reviewed by: Michele Guerrini All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc. Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden FILE COPY NORTHWEST HAN DLI NG SYSTEMS, I N C. The Material Handling Experts 1100 SW 7th St Renton, WA 98055 (425) 255-0500 ph (425) 228-6946 fax ATTN: BUILDING DEPARTMENT AND FIRE DEPARTMENT RACK INFORMATION SUPPLEMENT SITE ADDRESS: 1071 Andover Park East TENANT NAME: Yita, LLC DATE: September 30, 2014 APPLICANT: Mike Sorenson / (206) 818-4488 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 15 2014 City of Tukwila BUILDING DIVISION 1. Load application and rack configuration drawings attached. 2. Attached plans and engineering detail the rack locations, dimensions, and specifications. 3. Stamped engineering calculations attached. 4. Inspections will be scheduled as instructed. 5. Vertical members of storage racks are designed and installed so that failure of one vertical member will not cause collapse of more than the bay or bays directly supported by that member. 6. Commodities stored in racks: LED light bulbs for automotive, marine, and motorcycle industries. Light bulbs stored in small cardboard packets within larger cardboard boxes. Boxes stored on wire mesh decks directly on racking. Not encapsulated. 7. Sprinkler System Information: Wet system: 150 psi static, 125 residual. 8. Building exits indicated on attached drawings. 9. Maximum product storage height: 13'. Overhead clearance: 16'. fhLt.:tiVED CITY OF TUKWILA OCT 0 3 2014 PERMIT CENTER DIy-0321 BY G. OHANIAN DATE. 9-27-14 SUBJECT RAdK DEIGN & ENGINEERING do. 412 WEOT BROADWAY, QUITE #204 dLENDALE, OA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO. 1 . RD-17588 JOB NO. STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: YITA, LLC 1071 ANDOVER PARK EAST TUKWILA, WA 98188 PER IBC 2012 EDITION STORAGE RACKS CAPACITY: 1800 # / LEVEL CALCS. 1 THRU 4 DRAWINGS: RD-17588 FILE COPY w.....r.{i JA. EXPIRES 12-26-15 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 15 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 0 3 2014 PERMIT CENTER Ptt4 oI BY G. OHANIAN DATE.9-27-14 SUBJECT RACK DEOIdN Sc EN(4INEERINC4 CO. 412 WEOT BROADWAY, QUITE #204 dLENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO. 2 JOB NO.. RD-17588 0 N 0 0 L. O BEAM 96" 11 11 1• 11 SEISMIC DESIGN SDSXI Rx1.4 XW CO 44" PALLET RACK SIDE VIEW Ix=1.8 Sx =.8 FY= 55 KS'. LOAD PER BEAM + 25% IMPACT LOAD (1.8 Kx.88)+(.9 Kx.25)— 1_8 — .9 K 2 BEAMS M= 82 =11"K S R= .4<.8 _ SxwL4 L 384.Ix.E=.4" <180 =.53" IBC 2012 AND RMI SPECS. S DS =0.96 (USGS WEB SITE, "SITE CLASS D") 1=1 NO PUBLIC ACCESS R=6 MOM. CONN. R=4 BRACED W=D.L.+ 3 PALLET LOAD LOAD PER COL. = 3x1 .8 K -2 7 K 2 coL. P=.2DL+ (2.7KX0.75)=2.2K W=.2DL+ (2.7PLx0.67)= 2.0 K LONGIT..23 K V = .34K TRANS. LONGIT. SEISMIC O O 12K 1 6"K .07K 1.6"K = 2.6"K 05K 2.6"K= 13.3"K .23K BY G. OHANIAN DATE . 9-27-14 SUBJECT RAdK DE$I(N Sc ENdINEERIN(t dO. 412 WET BROADWAY, OUITE #204 LENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO 3 JOB NO. RD-17588 COLUMN ANALYSIS 3" x- —x t=.070" 1I� M U ' F 55 KSI Y= Ae=.62 I x=.95 Se=.6 rx=1.2 ry=1.1 KL=60x1.7 _85 rx 1.2 rL= 52 38 Y • Mn=Se.Fy=33 COMBINED STRESS RATIO Pex=n2E.lx=27 Qc=1.8 fZc.P+f2b.Cmx.M =.9<1 (KL) 2 Pn Mn.ax f2cP Ob=1.67 ax=1— Pex = .85 Cmx=.85 BASE PLATE ANCH. TENSION = 0 ANCHOR SHEAR = .12 K (1)-1/2"0 ANCHOR PER BASE PL., 3 1/4" EMB. HILT! KWIK BOLT—TZ ESR-1917 SPECIAL INSPECTION IS REQUIRED MOMENT AT BEAM CONNECTION 2 Fe=(KL)2=40 rx 2 F n=F Y(.658 A o )=31 KSI Pn= Fn .Ae = 18.0 K 2 2K .5x.07x1 x65=2.3 K BEARING CAPACITY OF COL. HOLE 2 6." 8.0 "K ® ® 8.0 ' 13.3' 7/16"525 RIVET A=.1 Fy=79KSI Pa = .1 x79x.4 = 3 K Ma = (2.3Kx4")+(1.1 Kx2") = 11.4"K 3 PIN CONN. CONN. MEND- .01 )(WI 2= 1.0"K M=8.0"K M=9.0"K SEISMIC TOTAL Ac=-\/Fy/Fe = 1.2 Ac<1.5 3"x4 1/2"x1/8" BASE PLATE N 3" BY G. OHANIAN DATE.9-27-14 SUBJECT RAdK DEOI(N Sc ENdINEERINd do. 412 WET BROADWAY, QUITE #204 LENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO 4 JOB NO.. RD-17588 OVERTURNING MoT=.34Kx2 x146"x0.66 =66 "K COL. MR = 2.2Kx44"= 97 "K NO UPLIFT LOAD TO DIAGONAL P=.34Kx2 x 54 =.9 K COL. 44 FY= 55 KSI Ae=.29 rx =.46 L= 54" P° = 2.9 K CHECK WELDS P°= (1_.01L)L.t.F° = 4.4K r2= 2.55 P� = 1.7Kx2 = 3.4K C2 SIDES CHECK SLAB 2200 _ 2.2 °' 1000 .34K 2.2x 144=317 V 317=18" M= (4'2 )2 x1000x 2 x12=844 "# s= 12x62 = 72 6 844 = 12 < 1.6 J 2500 =80 72 22K 22K IIx'I x I I `.l cV .34 K 0 44" TOP LEVEL LOADING 0 o W— O'2DL+'9LL 1.1 K LOAD PER COL. V= .19 K MoT=.19Kx2 x120"=45"K COL. MR = 1.1 Kx44" = 48"K BOTH SIDES TYP> 1 /8 V1.5" t 1/z. t=.06" TYP 2200# I ❑I ❑ 2 o 6" CONCRETE SLAB 2500 PSI. CONC. 1000 PSF. SOIL PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0321 DATE: 10/03/2014 PROJECT NAME: YITA LLC SITE ADDRESS: 1071 ANDOVER PK E X Original Plan Submittal Revision # Response to Correction Letter # Revision # before Permit Issued after Permit Issued DEPARTMENTS: G 10 'all BuildingDivision Public Works Fire Prevention Structural 41/41C. 10-13-121 ■ ❑ Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 10/07/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/04/14 Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Nr Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg D Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 NORTH WEST HANDLING SYS ,'`TC Page 1 of 2 Washington State Department of Labor & industries NORTH WEST HANDLING SYS INC Owner or tradesperson FRANCK, JAMES JEROME Principals FRANCK, JAMES JEROME, PRESIDENT KOSTY, CLARK RANDOLPH, TREASURER THOMAS, KEVIN A (End: 09/28/2011) Doing business as NORTH WEST HANDLING SYS INC WA UBI No. 600 051 641 1100 SW 7TH ST RENTON, WA98055-2939 425-255-0500 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. NORTHWH275JF Effective — expiration 04/06/1973-10/09/2015 Bond TRAVS Bond account no. 81 S103354822BCM Received by L&I 10/09/2001 Insurance Travelers Indemnity Co of Ame Policy no. Y6302C242044TIA14 Received by L&I 09/29/2014 Active. Meets current requirements. $12,000.00 Effective date 10/01/2001 Expiration date Until Canceled $1,000,000.00 Effective date 10/01/2014 Expiration date https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600051641 &LIC=NORTHWH275JF&SAW= 11/19/2014