Loading...
HomeMy WebLinkAboutPermit D14-0337 - CENTURYLINK - TENANT IMPROVEMENTCENTIJRYLINK 3355 S 120 PL D14-0337 LA °4v'��\rti City of Tukwila c, Department of Community Development =0 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 I90a Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No: 1023049082 Permit Number: D14-0337 Address: 3355 S 120TH PL BLDG 5 Issue Date: 11/14/2014 Permit Expires On: 5/13/2015 Project Name: CENTURYLINK Owner: Name: SABEY CORPORATION Address: 4TH FLOOR 12201 TUKWILA INTL BLVD, SEATTLE, DC, 98168 Contact Person: Name: ANDREW DUMART Phone: (202) 271-3003 Address: 730 ELEVENTH ST NW , WASHINGTON, DC, 20001 Contractor: Name: HITT CONTRACTING INC Phone: (703) 846-9000 Address: 2900 FAIRVIEW PK DR, FALLS CHURCH, VA, 22042 License No: HITTCI*999JB Expiration Date: Lender: Name: CENTURYLINK Address: 3355 S 120 PL, TUKWILA, WA, 98168 DESCRIPTION OF WORK: TENANT IMPROVEMENT TO REPLACE FLOORING, CEILING, AND ARCHITECTURAL FINISHES. Project Valuation: $1,200,000.00 Type of Fire Protection: Type of Construction: IA Sprinklers: YES Fire Alarm: YES Fees Collected: $15,956.02 Occupancy per IBC: B Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: 125 Sewer District: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2014 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: I hearby certify that I have read and a ed this permit and know the same to be true and correct. All provisions of law and ordinances gove : this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulati g construction or the performance of work. I am authorized to sign and obtain this development permits'. the conditions attached to this permit. Signature: Print Name: r;S D2/I11`r_ht,:k 1 Date: 11/4y/I41 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 20: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 23: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 13: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 14: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 15: Maintain fire extinguisher coverage throughout. 19: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 17: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 16: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 21: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 22: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 18: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 24: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 25: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** CITY OF TUKTM."`1A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** King Co Assessor's Tax No.: '(2.17014-- L+ Site Address: 3355 S 120th PI, Tukwila, Washington Tenant Name: CenturyLink Technology Solutions Suite Number: Floor: Pl Name: Sabey Corporation Address: 3355 South 120th Place City: Tukwila State: WA zip: 98168 Name: Andrew Dumart Address: 730 Eleventh Street, NW City: Washington State: DC Zip: 20001 Phone: (202) 271-3003 Fax: Email: adumart@mgac.com Company Name: II l.n 1CA(4 4, Address: 2900 State: t) Zip: Z2 0L1 z Phone: -70.3 9 Z 9 , ` 3 Fax: Contr Reg No.: t.y ,,r(�c r i Q n Tukwila Business License No.: �otc1ukt gGleca�l4 New Tenant: ❑ Yes ..No Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: Email: Company Name: Power Cool Engineers Engineer Name: Allen Ratliff Address: 321 Maple Lane, Suite 101 City: Blountville State: TN Zip: 37617 Phone: (423) 279-7840 Fax: (423) 279-7846 Email: aratliff@powercooleng.com Name: e tor ;;5 5 50.. h 12t54' ?fact Address: City: .7- State: W ' Zip: n 6 ( bQ) H:Wpplicationaorms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 1 of 4 BUILDING PERMIT INFORMATIO'206-43.1-3670: Valuation of Project (contractor's bid price): $ . of 41,2.00,.. Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Replacement of flooring, ceiling, architectural finishes and adding electrical equipment. Will there be new rack storage? ❑ Yes I u Floor I.. No If yes, a separate permit and plan submittal will be required. Provide All ,Building rAreas ::in, Square Footage Below Existing 188,298 Interior Remodel 4,920 Addition to Existing Structure: 'New. Type of `Construction per IBC �2" d;Floor 183,360 IA Type of Occupancy per 'IBC 3'1 Floor 183,360 13,669 Floors - thtu Basement Accessory: Structure* Attached Garage 'Detached Garage Attached Carport Detached Carport. `Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: EZ Sprinklers Z Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms-Applications On Line\201 I ApplicationsTermit Application Revised - 8-9-1I.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT I1 )RMATION — 206-433-0179 Scope of Work (please provide detailed information): Ca11 before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila ❑ ...Water District # 125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate ❑ ... Highline 0 ...Valley View ❑ ... Renton 0 ...Sewer Availability Provided 0... Renton ❑... Seattle Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34") ❑ .. Technical Information Report (Storm Drainage) ❑ .. Bond 0...Insurance ❑... Easement(s) Proposed Activities (mark boxes that apply): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - No Disturbance ❑ .. Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ .. Total Cut ❑ .. Total Fill cubic yards cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water ❑• ❑• ❑. ❑• ❑ ... Geotechnical Report ❑...Maintenance Agreement(s) ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) ❑ ... Right-of-way Use - Profit for less than 72 hours CI...Right-of-way Use — Potential Disturbance ❑... Work in Flood Zone ❑ ... Storm Drainage .. Abandon Septic Tank .. Curb Cut .. Pavement Cut .. Looped Fire Line 73 ❑ .. Permanent Water Meter Size (1) ❑ .. Temporary Water Meter Size (1) ❑ .. Water Only Meter Size ❑ .. Sewer Main Extension Public 0 ❑ .. Water Main Extension Public 0 WO # WO # WO # Private 0 Private 0 ❑ ... Grease Interceptor ❑ ... Channelization 0...Trench Excavation O ...Utility Undergrounding (2) " WO # (3) (2) " WO # (3) ❑ .. Deduct Water Meter Size " WO# " WO# FINANCE INFORMATION Fire Line Size at Property Line 0 .. Water ❑ .. Sewer ❑ .. Sewage Treatment Monthly Service Billing to: Name: Number of Public Fire Hydrant(s) Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H:Wpplications\Forms-Applications 0n Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 Page 3 of 4 PERMIT APPLICATION NO1 — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER Olbt�p ORIZ1 LL GENT: Signature: it Print Name: /ILG I 04, V El41-%-I Mailing Address: 3 A40 ,° Date: Day Telephone: VS S 37 S 315 &- Ifs Tel 3?z) City State Zip H:\Applications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 .441111111111F- Page 4 of 4 Cash Register Receipt City of Tukwila Receipt Number R3565 DESCRIPTIONS I ACCOUNT I QUANTITY PermitTRAK I PAID $15,956.02 D14-0337 Address: 3355 S 120TH PL BLDG 5 Apn: 1023049082 $15,956.02 DEVELOPMENT $15,486.86 PERMIT FEE R000.322.100.00.00 0.00 $9,383.25 PLAN CHECK FEE R000.345.830.00.00 0.00 $6,099.11 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $4.50 TECHNOLOGY FEE $469.16 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R3565 R000.322.900.04.00 0.00 $469.16 $15,956.02 Date Paid: Friday, November 14, 2014 Paid By: HITT CONTRACTING INC. Pay Method: CHECK 70269281 Printed: Friday, November 14, 2014 12:33 PM 1 of 1 riLJ V SYSTEMS 1INSPECTION RECORD 11 Retain a copy with permit INSPECTIMr0. PERMIT NO. 6300 Southcenter Blvd,, #100, Tukwila. WA 98188 (206) 431-367 CITY OF TUKWILA BUILDING DIVISION Permit Inspection Request Line (206) 438-9350 P -0337 Project: I r Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: aApproved per applicable codes. COMMENTS: EJCorrections required prkr o approval. gcc xiL 04 c,r- 10*Iteaots- r/s-t4,14-1 inspector: Date:3 _1,3 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER D -b.;3-1 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Type of Inspection: Address: ' Suite #: 35 .,,C.ti,_ .S S. \2.c. Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Esc Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:' „*.,..-A- 3 Date: 3/4,/jc Hrs.: /. 6 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0337 DATE: 10/23/2014 PROJECT NAME: CENTURYLINK SITE ADDRESS: 3355 S 120 PL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: /0- 1 UDC, 10'' 111 Building Division Public Works ir114 Fire Prevention Structural /tv'' tO-M `(`/\ C' ('L A-P ® Planning Division Permit Coordinator n PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 10/28/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/25/14 Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) Esr Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 HITT CONTRACTING INC Page 1 of 2 Cli Washington State Department of Labor & Industries HITT CONTRACTING INC Owner or tradesperson HITT, BRETT R Principals HITT, BRETT R, PRESIDENT MALLAR, JAMES EDWARD, PRESIDENT UNTHANK, GARY WAYNE, SECRETARY Doing business as HITT CONTRACTING INC WA UBI No. 602 062 110 2900 FAIRVIEW PARK DR FALLS CHURCH, VA22042 703-846-9000 Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. HITTCCI863PM Effective — expiration 11/01/2014-11/01/2016 Bond Travelers Cas and Surety Co of America Bond account no. 400SD6231 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 02/27/2006 10/10/2014 Expiration date Until Canceled Bond history Insurance Hartford Fire Ins Co Policy no. 42CSEQU2291 $1, 000, 000.00 Received by L&I Effective date 10/10/2014 03/01/2014 Expiration date https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602062110&LIC=HITTCCI863PM&SAW= 11/14/2014