Loading...
HomeMy WebLinkAboutPermit D14-0348 - NGUYEN YEN - TENANT IMPROVEMENTYEN NGUYEN 17035 SOUTHCENTER PKWY EXPIRED 06/07/15 D14-0348 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No: 2623049070 Permit Number: D14-0348 Address: 17035 SOUTHCENTER PKWY Issue Date: 11/26/2014 Permit Expires On: 5/25/2015 Project Name: YEN NGUYEN Owner: Name: KTM GROUP LLC Address: 223 TAYLOR AVE N #110 C/O METRO PROPERTY SVCS, SEATTLE, WA, 98115 Contact Person: Name: TR NGUYEN Phone: (206) 850-1244 Address: 2601 NE 12 ST, RENTON, WA, 98056 Contractor: Name: MTR CO INC Phone: (206) 850-1244 Address: 4228 S CHICAGO ST, SEATTLE, WA, 98118 License No: MTRCOCL862CM Expiration Date: 2/14/2016 Lender: Name: SELF FUNDED - YEN NGUYEN Address: DESCRIPTION OF WORK: TENANT IMPROVEMENT: NEW PLUMBING FOR SPA CHAIRS, NEW PORCELAIN FLOORING & NEW PAINT Project Valuation: $37,500.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: Type of Construction: VB Fees Collected: $1,363.32 Occupancy per IBC: B Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2014 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No Permit Center Authorized Signature: (L1V Date: f , t d—v,_" I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: s� / / Print Name: /L Date: 1(- (4 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 5: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 2: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 3: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 4: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 6: Maintain fire extinguisher coverage throughout. 7: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 8: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 10: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 9: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 11: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 15: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 13: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 12: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 17: An approved manual fire alarm system including audible/visual devices and manual pull stations is required for this project. The fire alarm system shall meet the requirements of Americans With Disabilities' Act (I.B.C.), N.F.P.A. 72 and the City of Tukwila Ordinance #2437. 18: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 16: All newfire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 19: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 20: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 21: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 14: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 24: ***BUILDING PERMIT CONDITIONS*** 25: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 26: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 27: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 28: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 29: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 30: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 31: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 32: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 33: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0502 LATH & GYPSUM CITY OF TU. ILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. Project No. Date Application Accepted: Date Application Expires: For o zee use on CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION , 7 0 3 s� c TA-Vs-xic Site Address: Tenant Name: PROPERTY OWNER Name: Address: -2) TeA-44tgr- Le 1•1*- 100 ? ,2, City: SA- -44-n State: w Zip:1 Q t 0 CONTACT PERSON - person receiving all project communication Name: -T-g_ r- �1.-t y Ai Address: 2 f �7 /�© r e 0-.1/4, 4/, �j City: State: Zip: Phone: =lbL_gco- I24F : Ldr Email: T,) M /,_ Ll ��'... 9,t Gz- b �-CYYz T GENERAL CONTRACTOR INFORMATION Company Name: MT R._ CO L L c_ Address: 4 2 Z 6' 5 . (-4.(cA-Pro ?r fErriery5E-: City: , State: Zip: ) 6,4 i 7—c_C {Ai A '? 2t e Phone: CC, Z Contr Reg No.: x ate: P�j 1 160f�L cC-M 2- 1z- /6 Tukwila Business License No.: King Co Assessor's Tax No.:: Suite Number: Floor: New Tenant: Q Yes No ARCHITECT OF RECORD Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: /6.- / A , Yc il Address: / 7 D 3 7,,g6,,-,�',''41i14, City: i--(A %-wi ( Stat,eys._ H:Wpplications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 1 of 4 BUILDING PERMIT INFORMAT ¶ — 206-431-3670 Valuation of Project (contractor's bid price): $ 37 , Sot Existing Building Valuation: $ Describe the scope of work (please provide detailed information): N-I a-v.l lue vt) f,CD Q.o.;l i cel Will there be new rack storage? ❑ ....Yes (No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below 7--- Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1st Floor 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes e No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ii Sprinklers ❑ Automatic Fire Alarm 0 None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes gi. No If 'Yes ', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bb Page 2 of 4 PUBLIC WORKS PERMIT INi tMATION — 206-433-0179 Scope of Work (please provide detailed information): '7j 7"°- Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila ❑ ...Water District # 125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate ❑... Highline ❑ ...Valley View 0... Renton ❑ ...Sewer Availability Provided 0... Renton 0... Seattle Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which applv): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34") ❑ .. Technical Information Report (Storm Drainage) ❑ .. Bond ❑... Insurance 0... Easement(s) Proposed Activities (mark boxes that apply): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - No Disturbance ❑ .. Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ .. Total Cut ❑ .. Total Fill cubic yards cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation ❑... Geotechnical Report 0... Maintenance Agreement(s) ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) O ...Right-of-way Use - Profit for less than 72 hours ❑ ... Right-of-way Use — Potential Disturbance O ...Work in Flood Zone 0... Storm Drainage 0...Abandon Septic Tank 0... Curb Cut ❑... Pavement Cut El...Looped Fire Line Domestic Water ❑ .. Permanent Water Meter Size (1) ❑ .. Temporary Water Meter Size (1) ❑ .. Water Only Meter Size ❑ .. Sewer Main Extension Public ❑ .. Water Main Extension Public WO # WO # WO # Private ❑ Private ❑ 0... Grease Interceptor ❑... Channelization ❑ ... Trench Excavation ❑... Utility Undergrounding (2) " WO # (3) (2) " WO # (3) 0 .. Deduct Water Meter Size " WO# " WO# FINANCE INFORMATION Fire Line Size at Property Line 0 .. Water ❑ .. Sewer ❑ .. Sewage Treatment Monthly Service Billing to: Name: Number of Public Fire Hydrant(s) Day Telephone: Mailing Address: C Water Meter Refund/Billing: Name: Mailing Address: ri State Zip Day Telephone: City State Zip H:Wpplications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 3 of 4 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTI4,117AGENT: Signature: Print Name: 1-^ �✓ �j I 0Ye 0v Mailing Address: J__Cy 0 ( C I -2 - ity City Day Telephone: Date: /1- j - ftr ath G✓� gar — State Zip H:WpplicationskForms-Applications 0n Line\2012 Applications\Permit Application Revised - 2-7-I2.docx Revised: February 2012 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PAID PermitTRAK $1,911.60 D14-0348 Address: 17025 SOUTHCENTER PKWY Apn: 2623049070 $1,363.32 DEVELOPMENT $1,323.35 PERMIT FEE R000.322.100.00.00 0.00 $799.30 PLAN CHECK FEE R000.345.830.00.00 0.00 $519.55 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $39.97 TECHNOLOGY FEE R000.322.900.04.00 0.00 $39.97 M14-0203 Address: 17025 SOUTHCENTER PKWY Apn: 2623049070 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 0.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE I R000.322.900.04.00 0.00 I $8.51 PG14-0166 Address: 17025 SOUTHCENTER PKWY Apn: 2623049070 $326.96 PLUMBING $314.38 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $219.00 PLAN CHECK FEE R000.322.103.00.00 0.00 562.88 TECHNOLOGY FEE $12.58 TECHNOLOGY FEE R000.322.900.04.00 TOTAL FEES PAID BY RECEIPT: R3482 0.00 $12.58 $1,911.60 Date Paid: Wednesday, November 05, 2014 Paid By: YEN NGUYEN Pay Method: CHECK 1075 Printed: Wednesday, November 05, 2014 11:53 1 of 1 AM CSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO, PERMIT NO. 4,0 • CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd,, #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project Type of jpspectis Address: Date Called: Special Instructions: Date Wanted: Requester: gifApproved per applicable codes. Corrections required prior to approvaL COMMENTS: Inspector: Date:IL 14, REINSPECTIONfEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Stvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: Requester: Phone No: EjApproved per applicable codes. EJCorrections required prior to approval. COMMENTS: ,REINSPECTION FEE REQUIRED. Prior to next inspedion, fee must be v paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. FILE COPY Permit No. pli-komi Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: ILDING DIVI CO, LLC SEPARATE PERMIT REQUIRED FOR: Mechanical 14 Electrical Plumbing I Gas Piping City of Tukwila BUILDING DIVISION 2601 Ne 12th St. Renton,Wa 98056 Phone: (425) 277-5432-Toll free:1-888-882-4488 - Fax: (425)255-5679 Space size: 1,400 sf 79" 114" 103" 97" 130' 87" 100" ,ap" Existing Restroom 32' Existing Breakroom Existing Sink New Waxing room New Waxing room #1 /' 32. Manicure Table Entrance Manicure Table L J Manicure Table Customer 20N20° Demising Wall Chair 205Q0" Chair 205(20' Chair 20fQ0' Demising Wall Pony Wall 26" tall Chair 205QA" Floor Plan 83" REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may -include additional plan review feed Job name: K&Y NAIL SPA Site address: 17035 SOUTHCENTER PARKWAY - TUKWILA Stacked W/D /water heater/ Electric water heater Spa chair 32'KTY Spa chair 32'x72 a 1 a 100" COMM WALL 20 GA GALV METAL TRACK 20 GA. GALV METAL TRACK SCREWED TO FLOOR WITH #8 LAG SCREWS @ 24' O.C. Metal Stud Bracing bar TYP. WALL FRAMING: S/8" TYPE 5C GYP. BOARD OVER METAL FRAMING 96" 20 GA. GALV 3-1/2' METAL STUDS ® 24" O.C. I.25" PLYWOOD TENANT IMPROVEMENT AS LISTED BELOW 1) Building 2 new rooms as shown on plan 5/8" Drywall on 3.5" Metal studs. @24"O.C. 2) Existing Ceiling (remain the same) 3) 11 New plumbing fixtures (by plumbing contractor permit separately) 4) Install one new exhaust fan 350cfm (permit separately) 5) Electrical permit separately by 6) New tile floor CORRECTION: 1- * Two waxing rooms are new. * Plumbing wall is new 26" tall. (p cover plumbing pipes) *A little back boxes are indicated for 110v outlets. 2- * The wall detail drawing was intended for waxing rooms. * The Plumbing wall is to install against the existing demising wall. (to be covered one side) * Each room has one 20 gage 2"x 4" metal stud Braced 45 degree with demising wall (main structure). 3-* Existing 24" x 48" ceiling panels are existing (no change) * Install one new Exhaust Fan 350cfm with 4 of the 8" inlet in the ceiling vertical dischage through roof. * No changes for existing ventilation in the bathroom. 4-* Total 11 of new Plumbing fixtures (9 spa chairs, 1 hand sink, and one Washer - Please see attached plumbing drawing) * Dryer exhaust with 4" metal duct traight up through roof. t • II FO ILIANRCE APPROVED NOV 2 0 2014 City of u t iia BUILDING i ISION i MTR CO, LLC 2601 Ne 12th St. Renton, Wa 98056 Phone: (425) 277-5432-Td hee:1-888-882 4488 - Far. (425)255-5679 Mumma; K&Y NAIL SPA SILI: 17035 SOUTHCENTER PARKWAY -TUKWILA REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 0 2014 CBUILDING Tukwila VISION Existing light panels 12 existing Light panels 24" x 48" No additional lights to be installed. Space size: 1,400 sf Existing Ceiling Light Plan Space size: 1,400 sf 8" gravity back draft damper makeup air (located on the West wall) y MTR CO, LLC 2601 Ne 12th St. Renton, Wa 98056 Phone: (425)277-5432- Toll free:1-888-882-4488 - Fax: (425)255-5679 E.) 8" metal ducting Inlet #1 Electric dryer Stacked W/D Electric water hex water heater 8" metal ducting Inlet #2 350 cfm fan (Exhaust vertically through roof) Inlet #3 Inlet #4 rt 4" Dryer exhaust (through rooftop) Job name: K&Y NAIL SPA Site address: 17035 SOUTHCENTER PARKWAY -TUKWILA REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 0 2014 City of Tukwila BUILDING DIVISION * Install one Broan 350 cfm Exhaust ventilation fan (Vertically Exhaust through roof top) * Electric clothing Dryer. Exhaust through roof top. * Opening 8" makeup air located on the West wall. MECHANICAL PLAN Exhaust minimum 10' from any air intake Roof line 10" Metal duct Ceiling 350 cfm fan (Exhaust vertically through roof) Mounting support to trusses 8" Metal duct t t t 8"inlet 8"inlet 8" inlet t 8" inlet K . Y NAIL 5 PA 5OoTuCektf Q P2ywA voaa_ tiSit 9(A61.144 Nor To SCA - S PA C 1PtLQ.S AU 2 FA) . EACH . 22 r. U . COLD NET t OLD 1 tier Nor LQ TO 5P °HA SEPARATE PERMIT AND APPROVAL REQUIRED -TV 9 kcy NAIL SCA 50011-1 CENTER_ Pki4,1,0 - WASTE L VENT- 'DIAGQAM , NOT TO SCALE 1H I5 Vf AWINC3 15 F02_ 5itIr tG CialtRAL LAY-OO i SNIR OAP ARMS Aim Level; bF SEPARATE PE'ilivilT AM: APPROVAL MIMED vvlkffri 4 '4 MACHINE oasis P I99.1 DETAIL, City of Tukwila Department of Community Development 5/1/2015 TR NGUYEN 2601 NE 12 ST RENTON, WA 98056 RE: Permit No. D14-0348 YEN NGUYEN 17035 SOUTHCENTER PKWY Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 6/7/2015. Based on the above, you are hereby advised to: 1) Ca11 the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 6/7/2015, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, ')A1P Bill Rambo Permit Technician File No: D14-0348 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development November 12, 2014 TR NGUYEN 2601 NE 12 ST RENTON, WA 98056 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D14-0348 YEN NGUYEN - 17035 SOUTHCENTER PKWY Dear TR NGUYEN, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) Structural Drawings and structural calculations sheets by a registered engineer shall have a current signed stamp -seal. Architectural design sheets and documents by a registered architect shall also have a current signed stamp -seal. (BUILDING REVIEW NOTES) 1. Provide additional information on the plan specifying which rooms are new, which walls are new with some sort of a legend. Plan shows little black boxes at different locations on perimeter walls. Please specify all elements for clarification. 2. The one wall detail appears to show a new wall against an existing demising wall. The detail shows gyp board on both sides of that new wall. Is the intent to have that wall with gyp board on both sides and how will that be installed when against the other wall? It is assumed this is a plumbing wall. Provide clarification on the plan. Also show each new wall braced at the top in a detail. Walls shall be secured independent of the suspended ceiling grid. 3. Provide a reflective ceiling plan that shows existing lighting and any new lighting added or lighting relocated. Identify mechanical ventilation in the ceiling and any changes or additions to ventilation and fans. An energy code lighting budget form shall be required if additional lighting is to be installed. 4. Clearly identify all new plumbing fixtures on the floor plan. Specify if the stacked washer and dryer is new on the plan and show where the dryer shall exhaust to the outside with details for penetrations and locations of exhaust per mechanical code. This shall be included on the mechanical permit. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300.Snuthrvnter Rnnlvvnrd ,Suite d#lnn • Trikwiln Wnshinotnn 910RR • Phnnn 206-431-3670 • Fnr 7n6-431-3665 If you have any questions, I can be reached at 206-431-3655. Sincerely, Bill Rambo Permit Technician File No. D14-0348 6 nn.Cmithrontor Rnulvvnrd .Cuito #lnn • Tukwila Wnchinotnn 9RIRR a Pliny'', 91)6-d?1-?670 • Fnr 7n(,-d?1-?F(S °ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0348 PROJECT NAME: YEN NGUYEN DATE: 11/17/2014 SITE ADDRESS: 17035 SOUTHCENTER PKWY Original Plan Submittal X Response to Correction Letter # 1 Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural n Planning Division Permit Coordinator n PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 11/18/14 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 12/16/14 Approved n Approved with Conditions Corrections Required ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: \ir("' n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0348 DATE: 11/05/14 PROJECT NAME: YEN NGUYEN ri.60 S SITE ADDRESS: 49 SOUTHCENTER PKWY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: GOB L 1L-7- v\ Building Division OE I`OK 400 Public Works Fire Prevention Structural lA i1 �< H Planning Division Permit Coordinator 11 PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 11/06/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Corrections Required Denied (corrections entered in Reviews) ' (ie: Zoning Issues) DUE DATE: 12/04/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: / - 17 .. l Ly Plan Check/Permit Number: D 14-0348 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ctrEMED ro ruhrotriut .NOY 17 2014 Peniarcarrap Project Name: Yen Nguyen Project Address: 17035 Southcenter Pkwy Contact Person: %/2 NC-c iy6r✓ Phone Number: 2 b.0 ' s c - L 2 "( Summary of Revision: il� Q Cxn c.,5t^ r-P_ C--•fi y-, Z5 P-4. Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Zr Entered in TRAKiT on /02//cf \applications\forms-applications on Iine\revision submittal Created: 8-13-2004 Revised: MTR Co LLC Page 1 of 3 10 Washington State Department of Labor & Industries MTR Co LLC Owner or tradesperson Lougher, Robert F Principals Lougher, Robert F, PARTNER/MEMBER Lieu, Toan H, PARTNER/MEMBER Doing business as WA UBI No. 603 376 149 4228 S Chicago St SEATTLE, WA 98118 206-850-1244 KING County Business type Limited Liability Company Governing persons ROBERT F LOUGHER License Verify the contractors active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. MTRCOCL862CM Effective — expiration 02/14/2014— 02/14/2016 Bond Active. Meets current requirements. American Contractors Indem CO $12,000.00 Bond account no. 100241200 Received by L&I Effective date 02/14/2014 02/13/2014 Expiration date Until Canceled Insurance Contractors Bonding & Insuranc $1,000,000.00 Policy no. C11SK0519 Received by L&I Effective date 02/14/2014 02/13/2014 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603376149&LIC=MTRCOCL862CM&SAW= 11/26/2014