Loading...
HomeMy WebLinkAboutPermit D14-0359 - BOEING #9-120 - ROOF HANDRAILBOEING #9-120 ROOF HANDRAIL 9725 E MARGINAL WAY S D14-0359 City of Tukwila Department of Community Development joJ 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 6 Phone:206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov Parcel No: Address: DEVELOPMENT PERMIT 0003400018 9725 E MARGINAL WAY S BLDG 9-120 Project Name: BOEING #9-120 ROOF HANDRAIL Permit Number: D14-0359 Issue Date: 12/9/2014 Permit Expires On: 6/7/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: THE BOEING COMPANY Address: PO BOX 3707 M/C46-88 , SEATTLE, WA, 98124 BOEING COMPANYTHE PO BOX 3707 M/C 20-00 PROPERTY TAX DEPT, SEATTLE, WA, 98124 JOHN S MURDOCH PO BOX 3707 M/C 89-14 , SEATTLE, WA, 98124 BOEING COMPANY, THE 100 N RIVERSIDE, M/C 5003-4027 , CHICAGO, IL, 60606-1596 BOEINC*294ML Phone: (253) 657-0868 Phone: (312) 544-2535 Expiration Date: 1/18/2015 DESCRIPTION OF WORK: INSTALL GUARDRAIL/HANDRAIL TO MATCH CURRENT SYSTEM Project Valuation: $18,700.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: IIB Electrical Service Provided by: TUKWILA FIRE SERVICE Fees Collected: $791.10 Occupancy per IBC: B Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE,VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: 1 hearby certify that 1 have read and •xamin•d this permit and know the same to be true and correct. All provisions of law and ordinances gov ning his work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws re• ulating construction or the performance of work. 1 am authorized to sign and obtain this developmen rermitI nd agree to the conditions attached to this permit. Signature: Print Nam Date: Z; This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMITCONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: Readily accessible access to roof mounted equipment is required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 4046 SI-EPDXY/EXP CONC Y CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No.��'' Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. ' Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION 9-izo King Co Assessor's Tax No.: OW ViO —00 (r Site Address: 9725 East Marginal Way So. Tenant Name: The Boeing Company Suite Number: 9-120 Floor: 3 PROPERTY OWNER Name: The Boeing Company - John S. Murdoch Address: P.O. Box 3707 M/C 46-88 City: Seattle State: WA Zip: 98124 CONTACT PERSON — person receiving all project communication Name: John S. Murdoch - The Boeing Company Address: P.O. Box 3707 M/C 46-88 City: Seattle State: WA Zip: 98124 Phone: (253) 740-0214 Fax: Email: john.s.murdoch@boeing.com GENERAL CONTRACTOR INFORMATION Company Name: The Boeing Company Address: P.O. Box 3707 M/C 46-88 City: Seattle State: WA Zip: 98124 Phone: (253) 740-0214 Fax: (253) 657-0858 Contr Reg No.: BOEINC*294ML E.xp Date: 01 /18/2015 Tukwila Business License No.: H:\AppIications\Forn-Applicationz On Litc12011 Applications\Pcrmil Application Revised - 8-9-11.doca Revised: August 2011 bh New Tenant: ❑ Yes. `'..No ARCHITECT OF RECORD Company Name: Z.G.F. Architect Name: Todd Stine Address: 925 4th Ave. Suite 2400 City: Seattle State: WA Zip: 98104 Phone: (206) 521-3430 Fax: Email: ENGINEER OF RECORD Company Name: Cofflnan Engineers Engineer Name: Emery S. Ojala Address: 1601 5th Ave Suite 900 City: Seattle State: WA Zip: 98101 Phone: (206) 623-0717 Fax. Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: The Boeing Company Address: P.O. Box 3707 M/C 46-88 City: Seattle State: WA Zip: 98124 Page 1 of 4 BUILDING PERMIT INFORMATION_- 206 431 3670 Valuation of Project (contractor's bid price): $ 18,700 Describe the scope of work (please provide detailed information): Install Guardrail/Handrail to match current system. Will there be new rack storage? ❑ Yes ls` Floor Existing Building Valuation: $ 50,000,000 ®.. No If yes, a separate permit and plan submittal will be required. Provide A11 Building Areas in Square Footage Below 180,170 Interior Remodel: Addition to '- • Existing:' °r Structure. 'Type of Coiisfruction per IBC II-B Type of "Occuparcy,per IBC, B 73,700 .3"'.Floor 73,700 Floors ...thm ` r Basement Accessory Structure* Attached Garage.': Detached Garage Attached Carport Detached Carport, CoveredDeck:. Uncovered Deck:. PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes m No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None 0 Other (specify) On Roof Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes I No If "yes', attach list of materials and storage locations on a separate 8-1/2 " x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of4 PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): D.N.A. Ca11 before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District - ❑ ...Tukwila ❑... Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate ❑ .. Highline ❑.. Valley View ❑ .. Renton ❑ ... Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic Svstem: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnicai Report ❑ ... Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) ❑ ... Hold Harmless — (SAO) ❑ ... Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑;...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ ...Total Cut cubic yards ❑ ...Total Fill cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements D. .Traffic Control ❑ ...Backtlow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size.. WO # ❑ ...Water Only Meter Size WO # ❑ ...Deduct Water Meter Size ❑ ...Sewer Main Extension Public ❑ Private ❑ ❑ ..Water Main Extension Public ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Applications\Foraa-Applications on Lii \2011 Applications\Persnit Application Revised - 8-9-11.docx Revised: August 201 I bh Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY • PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING'��1 cOTHO Z AGENT: — Signature! t Print Name: riV6 ewP�1Y John S. Murdoch - The Boeing Company Mailing Address: P.O. Box 3707 M/C 46-88 Date: 11/17/2018 Day Telephone: (253) 740-0214 Seattle WA 98124 City State Zip H:\Applications\Fortes-Applications On Line\2011 Applications\Permit Application Revised - g-9-11.docx Revised: August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $3,223.96 D14-0359 Address: 9725 E MARGINAL WAY S BLDG 9-120 Apn: 0003400018 $791.10 DEVELOPMENT $767.96 PERMIT FEE R000.322.100.00.00 0.00 $462.70 PLAN CHECK FEE R000.345.830.00.00 0.00 $300.76 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $23.14 TECHNOLOGY FEE R000.322.900.04.00 I 0.00 I $23.14 D14-0360 Address: 8701 E MARGINAL WAY S BLDG 14-01 Apn: 0007400033 $2,432.86 DEVELOPMENT $2,361.44 PERMIT FEE R000.322.100.00.00 0.00 $1,428.45 PLAN CHECK FEE R000.345.830.00.00 0.00 $928.49 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $71.42 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R3584 R000.322.900.04.00 0.00 $71.42 $3,223.96 Date Paid: Monday, November 17, 2014 Paid By: JOHN S MURDOCH Pay Method: CREDIT CARD 098246 Printed: Monday, November 17, 2014 4:23 PM 1 of 1 L9SYSTEMS -r INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter 8ivd,, #100, Tukwila. WA 98188 (206) 431-3670 permit Inspection Request Line (206) 438-9350 Project Type of npecton: / o e.-A4 ' - i ' ,i • , p.. A Address: J c5 p;4-o35 Special Instructians: Date Caljed: /<J /L/\d, Date Wanted: _- 1- -/ p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: f}eJ)':I ?t/4() 7 \\ c Ins p&tor: 1 - •- Is L REINSPECTION FEE REQIJ1RED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Catt to schedule reinspection. FILE COPY Permit No..._._. BOEING 9-120 Siding Replacement Seattle, Washington Guard Rail at West Wall Parapet STRUCTURAL CALCULATIONS October 2014 CEI Project #13710 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 6 2014 City of Tukwila BUILDING DIVISION SEATTLE ANCHORAGE BAYAREA GUAM HONOLULU LOSANGELES SPOKANE 1601 FithAvenue 907.276.6664 510.251.9578 671.300.7531 808.687.8884 818.285.2650 509.328.2994 CpECEVED NW ;i 7 201'? PEAMfrc COFFMAN NGINEERS L.AS1 t NG ,re;iv=i:; res.as i E ,:;m:cn vs Dly -Del Suite 900 Seattle,WA 98101 206.623.0717 W E -ST 1Wv F&- MM LLAcc L S n p�-& l ESL ! io Off. 5 0 �f if 7 D ti ?.oi� # Cvt-o ' p P€ - p{tic�PosNL p;0E L r.9'' 0.4. t.•nti 74tc�c �K = l.�o (-(S I— 5't� �-W o - 'f 4sr-c,, . o.L(v tK'(isL$i (o.g) ! ! o S - F'T ). 2u-1 (Stitt\ 3 • Oj1" 7 �l5Sa COFFMAN N G INEERS — (o&c N (.- 9- ! 2-0 by dme tvf i�f ded ono. SEA-81204 t Htb� 1 M.. w�* = ZSo# aZ°*' &dos' •- 3.�� t-------�1 C c:• PoS r S ()O )QoS� � J &. its s Zx 2,� 34�, Ll t, J <, R f-,t S E- `i'K i C 1c t•.,*1 ( t F �t" - O. `I (U•�`i�` �'�( Kb Ls �} 2-?-so -F ) /boo di-F 1 0 F-? Er-C c )*J ( b( c . !.,_ (-- ZED o.(3.xz (3.15'� tt') -A x 114 (.-1J08-' �coFFMaN N G I NEERS vim+ (DE- N Fr 9—c-. by c..v bno. SEA•B120t 1 T r Mac TE�-�S � �•+ - -c. o.ave'' COFFMAN N G LNEERS by bi. '-U1L-r1 wwwi iwua Profls Anchor 2.4.9 Company Spedlier Address: Phone 1 Fax: E-Mail: Page: Pmjecit; Boeing 9-120 Sub -Project I Pos. No.: West Weli Guard ReA Date: 10/24/2014 1 Specifler's comment,: 1 Input data Anchor type and diameter: Effective embedment depth: Meteriai: Evaluation SeMce Report: issued i Vend: Proof Standoff Installation: ProfUe: Base materiel: Reinforcement: Kwik Bolt TZ - CS 518 (3118) h.r = 3.125 in., h,..,,, = 3.583 In. Carbon Steei ESR-191T 5/1R01315/112015 design method ACI 3181 AC193 - (Recommended plate thickness: not calculated) no profile cracked concmta, 2500, f' = 2500 psi; h = 5.000 in. tension: condition B, shear. condition B; no suppiementai splitting reinforcement present edge reinforcement: none or < No. 4 bar Seismic loede (cat. C, D, E, or F) no Geometry (ln j 8 Loading pb, in.lb] z tnpot dera and maid b mat b. dmdted for apnee.,.M.an, ei. a tkp as cns and br ptaa IM PROFIS Md+or ( c 3 Z000.2oae Hitti AG, FL4494 Sdtian IkOtl ie a reQlseet.d Tredenwk or H@9 A0. Sdieen �■III�TI www.hlltLus Company Specifler Address: Phone 1 Fax: E-Mall: I Page: Project Sub -Project 1 Pos. No.: Date: Profls Anchor 2.4.9 2 Boeing 9-120 West wall Guard Rall 10/24/2014 2 Load case!Resulting anchor forces Loed case: Design loads Anchor reaeltons [fb] Tendon tome: (+Tension, -Compresslon) Anchor Tension force Shear force 1 25b0 1000 max. ooncrote compressive straln: max. concrete compresslve stress: muting tension force In (x/y) (O.000I0.000): resulting oompresslon force In (x/y) (0.000/0.000): 0 (lb] 3 Tenslon load Steel Strength* Pullout Strength• Concrete Breakout Strength*' • anchor having the highest loading 3.1 Steel Strength NM = ESR value 4 N.t,.t t N,- load N,- ]Ib] 2500 N/A 2500 *•enhor group (anchors In tension) refer to ICC-ES ESR-1917 ACI318-08 Eq.(D-1) Vartabes n A», II M•21 1 0.16 106000 calculeftons N« (Ibl 17170 Rssuttu Nr. (bl 17170 �0 4 N.I+bI Nu.Iibl 1�877 2500 Shear force x Shear force y 1000 0 -(mil -ill 0 (Ib) Capacltr (Ib) 1'181 NIA 3052 UBI izst1on Oµ - NJ+N„ N/A 82 Status OK N/A OK Input data and rawN mwt bra d+ed ed for apeam&t w5 toe d,* cmddcns and tar pW-bittyt PROFIS Mdror ( c ) 20012009 IAltf AO, FL-0494 Sdu-n I43d la a rapist -ad Tradan% k of 101 AG. Schram I-IlL.TI www.hifLus Company Specfer: Address: Phone 1 Fax: E-Mail: I Page: Project Sub -Project I Pos. No.: Date: Profis Anchor 2.4.9 3 Boeing 9-120 west wall Guard Ralf 10i24(2014 3.2 Concrete Breakout Strength N`e = (r�eO) Ww.N WaN Wa N Ne 0 N,a 2 N,. A eee ACI 318-08, PartD.5.2.1, Fig. RD.5.2.1(b) AN = 9 hw 1 WeaN = l 1 ) 51.0 3 hr Wed.N 0.7+0.3 (1 5h«)s 1.0 W =MAX(E,tc.c�)s1.0 Ne 'Ice Jt 'I h;rs Variables h,r (M-1 3.125 6.500 CalculaUone ANC M•�1 87.89 ResuNe Nth jib) 4696 ec N (in.] 0.000 ko 17 Aran M•�1 57.89 4.630 eel, jin.) 0.000 W.c1M 000 3052 ACI 318-08 Eq. (D-4) ACI 318-08 Eq. (D-1) ACI 318.08 Eq. (D-0) ACI 318.08 Eq. (D-e) ACI 318-08 Eq. (D-11) ACI 318.08 Eq. (D-13) ACI 318-08 Eq. (D-7) �.io1 8 .o000 4 (psij 2500 1.000 N1e pb) 2500 tod0 1.000 Ne (Ib1 4696 Input de9e ens bulb must be died d for II the ex tk+p ► pbwblkpA PROFIS Mdior 1 c ) 2003.2009liDO AO. FL9494 8doen 1.1011 b e npbbred Tademerk 00 Hitl AO, Sahan 1■■II�..TI www.hlltus Profis Anchor 2.4.9 Company Spedfer. Address: Phone 1 Fax E-Mail: 1 Page: 4 Project Boeing 9-120 Sub -Project 1 Pos. No.: West Wa11 Guard Rall Date: 10124/2014 4 Shear load Load Vr„ pb) Capacity;;V„ pb) Utllisagon v a VJ4V„ Status Steel Strength1000 5259 20 OK Steel fature (with lever armp WA WA NIA WA Pryout Strength" 1000 6574 18 OK Concrete edge tedlure In direction y+" 1000 4879 21 OK • anchor having the highest loading "anchor group (relevani anchors) 4.1 Steel Strength V„ = ESR value refer to iCC-ES ESR-1917 • V, 2 V,,, ACI 318-08 Eq. (D-2) Variables ^ A,.v P^•�1 iw (Ps11 1 0.16 106000 Catculatlons Va Pb1 8091 Ruulfs V„ [ib] ¢.s„r + V„ [ib] V(Ibj 8091 0.650 5259 1000 4.2 Pryout Strength VW v.d.N Vc.N Nb, gvcxvw Asee ACI 318-08, PartD.5.2.1, Fig. RD.5.2.1(b) AN,o = 9 h;r 1 W.�+s = 1 2 51.0 3 hw W,a$=0.7+0.3(,s1.0 W� N = MAX(, 1.0 csc ACI 318-08 Eq. (0-30) ACI 318-08 Eq. (0•2) ACI 318-08 Eq. (D-0) ACI 318-08 Eq. (0-9) ACI 318-08 Eq. (0-11) ACI 318-08 Eq. (D-13) ACI 318-08 Eq. (0-7) Variables h1 N+•1 ec1.N P^•1 ee2 N M•1 c. , P^•1 Z 3.125 0.000 0.000 8.000 1.000 8.500 17 1 2500 Calculetbns NN A, [M.nNb 2j As,,a ^•21 Is yIid.N yyrroc1.000 4898] 87.89 87.89 1.000 1.000 1.000 Results V[ib] • V,v [ib] Vs [ib] 9391 0.700 8574 1000 hipul d,b and »sulb neat b. drocked for a I.rnen1 wNh tlr..* iq ccnd lhi .. wrd br pIuuslbI,1 PROFIS Andror ( c J 2003.200e Hlftl AO, FL44e4 8chari Ht i is a r451& 4 7radamslc or Hptl AO. Schs.n www.hfltLus Profle Anchor 2.4.9 Company Spedfler Address: Phone 1 Fax: E-Mail: j Page: 5 Project Boeing 9-120 Sub -Project 1 Pos. No.: West Well Guard Raf Date: 10/24/2014 4.3 Con rsts ejdge fallure In dlrecllon y+ Vm — \ / Wsd.v Wav Wv WP.* V Vb +Vd,2V,� Ava see ACI 318-08, Part 0.6.2.1, Fig. RD.6.2.1(b) A4.5 c, 1 Wav= 1+2q F51.0 3c., W.d.v a 0.7 + 0.3(T_) S 1.0 WM1v+, 21.0 Vb a (7 (a) Vim) �. VTa c: a ACI 318-08 Eq. (D-21) ACI 31808 Eq. (D-2) ACI 318.08 Eq. (D-23) ACI 318-08 Eq. (D-28) ACI 318.08 Eq. (D-28) ACI 318.08 Eq. (D-29) ACI 318-08 Eq. (0-24) Variables c., nn•1 cn (n.1 ea„ P►+•1 Wav he Dn•1 6.000 6.000 0.000 1.000 5.000 I M.1 de Pn.1 fa [ps9 v 3.125 1.000 0.625 2500 2.000 Csiculatlons Ava [in•1 Aveo Dn.1 W.av Vb hb) 75.00 162.00 1.000 1000 .342 5811 Results V, nbl 4r. 4 Vm Ob1 V,, 11b1 6970 0.700 4879 1000 5 Combined tension and shear loads lltllizatlon j)Kv [%1 Status 0.819 0.205 5/3 79 OK 6 Warnings • Load re-dlsfrlbutlons on the anchors due to elastic detormatlons of the anchor plats are not considered. The anchor piste Is assumed to be sufnctenty stiff, in order not to be deformed when subjected to the loadingl • Condltlon A applies when supplementary relnforoement Is used. The m factor is increased for non -steel Design Strengths except Pullout Strength and Pryout strength. CondWon B applies when eupplementary relnforcement Is not used and for Pullout Strength and Pryout Strength. Refer to your local standard. • Refer to the manufacturer's product llterature for cleaning and Installatlon Instnxxlons. • Cheddng the trensfer of loads into the base rnatedal and the shear reslstance are requlred In acoordance with ACI 318 or the relevant standard) Fastening meets the design criteria! Input d w clod r.rfb mwt b. dr/dte0 (Or apresnm1 WIN me exMkg u m ams e d for p3aM4i PROF1S Andior ( c ) 2003-2005 H5t AO, F14454 $di i HOt Is e rs s..d Tredsnrt or H5 A0. Sd,esi I-HL. -I www.hlltLus Comp8n)r Spedtiier Addreas: Phona 1 Fax: E-Mall: I Page: Project Sub -Project 1 Poa. No.: Date: Profis Anchor 2.4.9 6 Boeing 9-120 west wall Guard Rall 10/24/2014 7 Installation data Anchor plate. steel: - Proflte: Hola diameter In the fbdure: - Plate thickness (Input): - Recommended plate tickness: - Cieantng: Manual cleaning of tha drilled hole according to Instruction Coordlnatss Mchor In. Anchor x y c. c., c c.y 1 0.000 0.000 6.000 - 60.000 6.000 Anchor type and diameter. Kwlk Bolt TZ - CS 5/8 (31/8) Inetaliation torque: 720.001 In.lb Hole diameter In the base matertal: 0.625 In. Hole depth In the base matertal: 3.750 In. Minimum thickness of the base matedal: 5.000 In. for use Is required. 8 Remarks; Your Cooperatlon Duties • Arty and all Infomratlon and data contained In tha Software concem solely the use of Hilti products and are based on the pdndpies, formulas and security regulations In accordance with Hltti's technical directions and operating, mounting and assemby Insbuctbns, ate., that must be strlctly complied with by tha user. All figures contained therein are average figures, and therefore use-spedtic teats are to be conducted prior to using the relevant Hlltl product The results of the catculatlons carded out by means of the Software are based essentlaly on the data you put In. Tharefore, you bear the sole responslblltty for the ebsence of arrors, tha completeness and the relevance of tha data to be put in by you. Moreover, you bear sole responsiblllty for heving the results of the calculation tedwd and deared by an expert, parrkulary wlth regard to compliance with appiicabta nouns and permits, prlor to using tham for your specific facility. The Software serves only as an aid to tnterpret nouns and pennNs without any guarentee as to tha absence of arrors, the correcbteas and the relevance of the results or sultablliy for a spec lflc eppllcation. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, of epplicabia, carry out the updates of the Software offered by Hilti on a regular basis.11 you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of tha Software In each case by carrying out manual updates via tha HINT Wabsite. Hlltl will not be liable for consequences, such as the recovery of bat or damaged data or programs, arising from a culpable breach of duty by you. bput de a snd nwuka nest be dsd�ad rar.are.nrnk win *be amm�ar and rar P PROFIS Mdwr( c) ZDO3.2005 HOtl A0 FL e4e4 adren I b b a •epWnd Tndsn t or Hie Aq 9dmn PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0359 DATE: 11/17/2014 PROJECT NAME: BOEING #9-120 ROOF HANDRAIL SITE ADDRESS: 9725 EAST MARGINAL WY S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: �5 Building Division Public Works Fire Prevention ® Planning Division Structural LI Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 11/18/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12/16/14 Approved Corrections Required n (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Stafflnitials: ivisrzoi3 BOEING COMPANY, THE Page 1 of 10 Washington State Departirpent of Labor & Industries BOEING COMPANY, THE Owner or tradesperson MCNERNEY, W (JAMES) Principals MCNERNEY, W (JAMES), PRESIDENT LOHR, MICHAEL, SECRETARY WOLTER, CHRISTOPHER, TREASURER READ, PAUL, SECRETARY (End: 02/07/2013) SHRONTZ, F A, SECRETARY (End: 02/07/2013) GIVAN, B E, SECRETARY (End: 02/07/2013) KING, C G, SECRETARY (End: 02/07/2013) BEIGHLE, D P, TREASURER (End: 02/07/2013) COLLINS, T J, TREASURER (End: 02/07/2013) BUDINICH, T M, TREASURER (End: 02/07/2013) WOODARD, R B, TREASURER (End: 02/07/2013) CRUZE, D D, TREASURER (End: 02/07/2013) CONDIT, P M, TREASURER (End: 02/07/2013) Doing business as BOEING COMPANY, THE WA UBI No. 178 005 030 100 N RIVERSIDE CHICAGO, IL60606-1596 312-544-2535 Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties https://secure.lni.wa.gov/verify/Detail.aspx?UBI=178005030&LIC=BOEINC*294ML&SAW= 12/09/2014 BOEING COMPANY, THE GENERAL License no. BOEINC*294ML Effective — expiration 07/13/1971— 01/18/2015 Bond FEDERAL INS CO Bond account no. 81312466 $12,000.00 Received by L&I Effective date 01114/2002 01/01/2002 Expiration date Until Canceled Insurance Ace American Insurance Company $10,000,000.00 Policy no. HD0G27337181 Received by L&I Effective date 10/02/2014 10/01 /2014 Expiration date 10/01 /2015 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts Page 2 of 10 No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID 700,216-00 Doing business as BOEING COMPANY THE Estimated workers reported N/A L&I account representative (360)902-4817 Self Insured. This business is certified to cover its own workers' comp costs. No premiums due. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=178005030&LIC=BOEINC*294ML&SAW= 12/09/2014