Loading...
HomeMy WebLinkAboutPermit D14-0388 - PHAN & NGUYEN RESIDENCE - REMODELPHAN & NGTJYEN RESIDENCE 4702 S 122"° ST D14-0388 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 3347401430 Permit Number: D14-0388 4702 S 122 ST Project Name: PHAN & NGUYEN RESIDENCE Issue Date: I `{ Permit Expires On:(0.j1 _.13 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: NGUYEN THUAN KIM THI 4702 S 122ND ST, TUKWILA, WA, 98178 SHARYN PARKER Phone: (206) 296-7437 7277 PERIMETER RD S , SEATTLE, WA, 98108 REGENCY NW CONSTRUCTION INC PO BOX 6429 , BELLEVUE, WA, 98008 REGENNC041J5 FAA (RANRIP) RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM, Phone: (425) 883-1301 Expiration Date: 3/2/2016 DESCRIPTION OF WORK: RENOVATION OF SINGLE-FAMILY HOME TO REDUCE NOICE INFILTRATION. THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TOT HE BUILDING FOOTPRINTS AND STRUCTURE INCLUDING REPLACEMENT OF WINDOWS WITH VINYL -FRAMED ACOUSTICAL WINDOWS, INSTALLATION OF SECONDARY ALUMINUM -FRAMED SLIDING GLASS STORM DOORS, INSTALLATION OF SWING -OUT ALUMINUM STORM DOORS, INSTALLATION OF CHIMNEY -TOP ACOUSTICAL DAMPERS AT FIREPLACES, AND ATTIC INSULATION. Project Valuation: $28,198.00 Type of Fire Protection: Sprinklers: Fire Alarm: , Type of Construction: VB Fees Collected: $1,129.22 Occupancy per IBC: R-3 Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: �Qk � Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Lee Cve9 7 Date: �2/-2 3/y This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0409 FRAMING 0606 GLAZING 0603 ROOF/CEILING INSUL CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. Project No. Date Application Accepted: Date Application Expires: t)k c(oHu (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: Tenant Name: -1✓2231 46th Ave. S. King Co Assessor's Tax No.: 0179000840 -fl02S 122 Suite Number: PROPERTY OWNER Name: (tMv 4Address:1 City: State: Zip: CONTACT PERSON — person receiving all project communication Name: Sharyn Parker Address: 7277 Perimeter Road South City: Seattle State: WA Zip: 98108 Phone: (206) 296-7437 Fax: (206) 269-7315 Email: Sharyn.Parker@kingcounty.gov GENERAL CONTRACTOR INFORMATION Company Name: not yet awarded Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Floor: New Tenant: ❑ Yes ..No ARCHITECT OF RECORD Company Name: SM Stemper Architects, PLLC 1 Architect Name: Timothy Fenlason Address: 4000 Delridge Way SW, Suite 200 City: Seattle State: WA Zip: 98106 Phone: (206) 624-2777 Fax: (206) 624-2973 Email: tfenlason@jonespayne.com ENGINEER OF RECORD Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: FAA (RANRIP) Residential Aircraft Noise Address: Remedy Improvements Program City: State: Zip: H:\Applications\Forms-Applications On Line\201 I Applications\Permit Application Revised - 8.9-I I.docx Revised: August 2011 bh Page 1 of 4 BUILDING PERMIT INFORMATI6r:—206-431-3670 Valuation of Project (contractor's bid price): $ 28,198 Describe the scope of work (please provide detailed information): Existing Building Valuation: $ Renovation of single-family home to reduce noise infiltration. This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: replacement of windows with vinyl -framed acoustical windows, installation of secondary aluminum -framed sliding glass storm doors, installation of swing -out aluminum storm doors, installation of chimney -top acoustical dampers at fireplaces and attic insulation. Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1st Floor 1,163 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: 1,163 Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? El Yes Compact: Handicap: O No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None 0 Other (specify) battery sm/CO Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes J No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. a\Applications\Forms-Applications On Line\201 I Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT IA vr:MATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District m ...Tukwila ❑...Water District #125 0 ...Water Availability Provided Sewer District ..• .Tukwila ❑ ...Sewer Use Certificate ❑...Valley View 0...Sewer Availability Provided ❑ .. Highline 0 .. Renton ❑ .. Renton ❑ .. Seattle Septic System: O On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which applv): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond 0 .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): 0 ...Right-of-way Use - Nonprofit for Tess than 72 hours 0 ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way 0 ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities O ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line 0 ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public 0 ❑ ...Water Main Extension Public 0 WO # WO # WO # Private 0 Private ❑ ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑...Deduct Water Meter Size t> FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer 0 ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES — INA Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR MWI1 IZED1 GENT: Signature: Date: Print Name: Titftothy FenlasDay Telephone: (206) 624-2777 Mailing Address: 4000 Delridge Way SW, Suite 200 ((f Seattle WA 98106 City State Zip H:Wpplications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PAID PermitTRAK $13,932.30 D14-0378 Address: 11664 44 AVE S Apn: 3347400690 $857.74 DEVELOPMENT $832.64 PERMIT FEE R000.322.100.00.00 0.00 $501.90 PLAN CHECK FEE R000.345.830.00.00 0.00 $326.24 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $25.10 TECHNOLOGY FEE R000.322.900.04.00 0.00 $25.10 D14-0379 Address: 4925 S 125TH ST Apn: 0179002840 $957.70 DEVELOPMENT $929.66 PERMIT FEE R000.322.100.00.00 0.00 $560.70 PLAN CHECK FEE R000.345.830.00.00 0.00 $364.46 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $28.04 TECHNOLOGY FEE R000.322.900.04.00 0.00 $28.04 D14-0380 Address: 12239 46TH AVE S Apn: 0179000830 $924.38 DEVELOPMENT $897.32 PERMIT FEE R000.322.100.00.00 0.00 $541.10 PLAN CHECK FEE R000.345.830.00.00 0.00 $351.72 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $27.06 TECHNOLOGY FEE R000.322.900.04.00 0.00 $27.06 D14-0381 Address: 12020 42ND AVE S Apn: 3347400290 $1,389.32 DEVELOPMENT $1,348.59 PERMIT FEE R000.322.100.00.00 0.00 $814.60 PLAN CHECK FEE R000.345.830.00.00 0.00 $529.49 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $40.73 TECHNOLOGY FEE R000.322.900.04.00 0.00 $40.73 D14-0382 Address: 12012 44TH AVE S Apn: 3347401060 $791.10 DEVELOPMENT $767.96 PERMIT FEE R000.322.100.00.00 0.00 $462.70 PLAN CHECK FEE R000.345.830.00.00 0.00 $300.76 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 Date Paid: Thursday, December 18, 2014 Paid By: PAMELA K KUEHL, KING COUNTY IN Pay Method: CREDIT CARD 015718 Printed: Thursday, December 18, 2014 12:17 PM 1 of 5 riiPPPFSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $13,932.30 D14-0382 Address: 12012 44TH AVE S Apn: 3347401060 $791.10 TECHNOLOGY FEE $23.14 TECHNOLOGY FEE R000.322.900.04.00 0.00 $23.14 D14-0383 Address: 11836 44TH AVE S Apn: 3347401015 $991.02 DEVELOPMENT $962.00 PERMIT FEE R000.322.100.00.00 0.00 $580.30 PLAN CHECK FEE R000.345.830.00.00 0.00 $377.20 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $29.02 TECHNOLOGY FEE R000.322.900.04.00 0.00 $29.02 D14-0384 Address: 13007 57TH AVE S Apn: 2137000020 $857.74 DEVELOPMENT $832.64 PERMIT FEE R000.322.100.00.00 0.00 $501.90 PLAN CHECK FEE R000.345.830.00.00 0.00 $326.24 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $25.10 TECHNOLOGY FEE R000.322.900.04.00 0.00 $25.10 D14-0385 Address: 12404 50TH PL S Apn: 0179002265 $1,311.30 DEVELOPMENT $1,272.86 PERMIT FEE R000.322.100.00.00 0.00 $768.70 PLAN CHECK FEE R000.345.830.00.00 0.00 $499.66 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $38.44 TECHNOLOGY FEE R000.322.900.04.00 0.00 $38.44 D14-0386 Address: 11608 40TH AVE S Apn: 7340600140 $1,545.38 DEVELOPMENT $1,500.06 PERMIT FEE R000.322.100.00.00 0.00 $906.40 PLAN CHECK FEE R000.345.830.00.00 0.00 $589.16 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $45.32 TECHNOLOGY FEE l R000.322.900.04.00 I 0.00 I $45.32 Date Paid: Thursday, December 18, 2014 Paid By: PAMELA K KUEHL, KING COUNTY IN Pay Method: CREDIT CARD 015718 Printed: Thursday, December 18, 2014 12:17 PM 2 of 5 1 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT I QUANTITY I PAID PermitTRAK $13,932.30 D14-0387 Address: 1223146 AVE S Apn: 0179000840 $724.46 DEVELOPMENT $703.28 PERMIT FEE R000.322.100.00.00 0.00 $423.50 PLAN CHECK FEE R000.345.830.00.00 0.00 $275.28 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $21.18 TECHNOLOGY FEE R000.322.900.04.00 0.00 $21.18 D14-0388 Address: 4702 5 122 ST Apn: 3347401430 $1,129.22 DEVELOPMENT $1,096.14 PERMIT FEE R000.322.100.00.00 0.00 $661.60 PLAN CHECK FEE R000.345.830.00.00 0.00 $430.04 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $33.08 TECHNOLOGY FEE R000.322.900.04.00 0.00 $33.08 M14-0222 Address: 11664 44 AVE 5 Apn: 3347400690 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 0.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 0.00 $8.51 M14-0223 Address: 12239 46 AVE S Apn: 0179000830 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 0.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 0.00 $9.00 M14-0224 Address: 4925 S 125TH ST Apn: 0179002840 $246.42 MECHANICAL $236.94 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $157.05 PLAN CHECK FEE R000.322.102.00.00 0.00 $47.39 Date Paid: Thursday, December 18, 2014 Paid By: PAMELA K KUEHL, KING COUNTY IN Pay Method: CREDIT CARD 015718 Printed: Thursday, December 18, 2014 12:17 PM 3 of 5 rJSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $13,932.30 M14-0224 Address: 4925 S 125TH ST Apn: 0179002840 $246.42 TECHNOLOGY FEE $9.48 TECHNOLOGY FEE R000.322.900.04.00 0.00 $9.48 M14-0225 Address: 12020 42ND AVE S Apn: 3347400290 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 0.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 0.00 $8.51 M14-0226 Address: 12012 44TH AVE S Apn: 3347401060 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 0.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 0.00 $9.00 M14-0227 Address: 11836 44TH AVE S Apn: 3347401015 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 0.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 0.00 $9.00 M14-0228 Address: 12404 50TH PL S Apn: 0179002265 $126.76 MECHANICAL $121.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $65.00 PLAN CHECK FEE R000.322.102.00.00 0.00 $24.38 TECHNOLOGY FEE $4.88 TECHNOLOGY FEE R000.322.900.04.00 0.00 $4.88 Date Paid: Thursday, December 18, 2014 Paid By: PAMELA K KUEHL, KING COUNTY IN Pay Method: CREDIT CARD 015718 Printed: Thursday, December 18, 2014 12:17 PM 4 of 5 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PAID PermitTRAK $13,932.30 M14-0229 Address: 13007 57TH AVE S Apn: 2137000020 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 0.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 0.00 $8.51 M14-0230 Address: 11608 40TH AVE S Apn: 7340600140 $258.96 MECHANICAL $249.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $166.70 PLAN CHECK FEE R000.322.102.00.00 0.00 $49.80 TECHNOLOGY FEE $9.96 TECHNOLOGY FEE R000.322.900.04.00 0.00 $9.96 M14-0231 Address: 1223146 AVE S Apn: 0179000840 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $147.40 PLAN CHECK FEE 8000.322.102.00.00 0.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 0.00 $9.00 M14-0232 Address: 4702 S 122 ST Apn: 3347401430 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 0.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R3797 R000.322.900.04.00 0.00 $8.51 $13,932.30 Date Paid: Thursday, December 18, 2014 Paid By: PAMELA K KUEHL, KING COUNTY IN Pay Method: CREDIT CARD 015718 Printed: Thursday, December 18, 2014 12:17 PM 5 of 5 SYSTEMS t 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd,, #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 cp- q plq-0308 Project: itikd V‘filt Ile( edttece. 'Type of Inwectiop: 144 f ...../ Address:_'_ (1707- Ca lz7- cf •-(.. . Date Called: Special Instructions: 4/ii Date Wanted: 11-ts-- a.m. P.m. Requester: Phone No: EjApproved per applicable codes. EJCorrections required prior to approval. COMMENTS: Inspector: r Date: - REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6380 Southcenter Blvd.. Suite 100. Call to schedule reinspection PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0388 DATE: 12/17/14 PROJECT NAME: PHAN & NGUYEN RESIDENCE SITE ADDRESS: 4702 S 122 ST X Original Plan Submittal Revision # before Permit Issued Revision # after Permit Issued Response to Correction Letter # DEPARTMENTS: 9g' /YWt 1Y-('?rIL( Building Division Public Works Fire Prevention Structural n Planning Division Permit Coordinator n PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 12/23/14 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 01/20/14 Approved Approved with Conditions Corrections Required n Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: I31dg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 REGENCY NW CONSTRUCTIC \C Page 1 of 2 Washington State Department of (1) Labor & industries REGENCY NW CONSTRUCTION INC Owner or tradesperson FOOTE, BRIAN LEE Principals FOOTE, BRIAN LEE, PRESIDENT Doing business as REGENCY NW CONSTRUCTION INC WA UBt No. 601 696 917 PO BOX 6429 BELLEVUE, WA 98008 425-883-1301 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. REGENNC041J5 Effective — expiration 04/25/1996— 03/02/2016 Bond TRAVELERS CAS & SURETY CO Bond account no. 103713311 Received by L&I 02/19/2002 Insurance Navigators Ins Co Policy no. sf13cg101922700 Received by L&I 02/11/2014 Insurance history Savings Active. Meets current requirements. $12,000.00 Effective date 02/20/2002 Expiration date Until Canceled $1,000,000.00 Effective date 02/20/2013 Expiration date 02/20/2015 No savings accounts during the previous 6 year period. (1T TT'S 1 /1 /!1 T1 T 11T,l. T1. T 1-1 /T A 1 TC n.. ('1 A IX 1_ 11 /r1 '1 //1/11 A KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00869C13 BID PACKAGE M-45 3-53-0058-047 SCOPE OF WORK RENOVATION OF RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE EC44IICALEN10 THE CONTRACT MECHANICALTICUDES ALL INFORMATION IN TI-1E DRAWINGS AND INCLUDING BUT NOT LIMITED APPLICABLE YES NO 1. SELECTIVE REPLACEMENT OF EXISTING WINDOWS WiTH NEW VINYL -FRAMED ACOUSTICAL WINDOWS. X 2. CUT DOWN OF WINDOWS TO COMPLY WITH EGRESS REQUIREMENTS. X 3. INFILL OF EXISTING OPENINGS. X 4. SELECTIVE REPLACEMENT OF INTERIOR / EXTERIOR DOORS WTH NEW ACOUSTICAL DOORS. X 5. INSTALLATION OF STORM DOORS. X 6. INSTALLATION OF SECONDARY SLIDING GLASS DOORS. X 1. INSTALLATION OF SECONDARY SKYLIGHTS. X 8. INSTALLATION OF PET DOORS. X X 9. INSTALLATION OF FIREPLACE FRESH AIR VENT. 10. INSTALLATION OF CHIMNEY CAP. X 1I. REGULATED MATERIALS ABATEMENT. X 12. ATTIC VENT BAFFLES. X 13. INSTALLATION OF ATTIC INSULATION. X 14. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, BLENDING AIR UNIT AND ASSOCIATED DUCTING. X 15. INSTALLATION OF MECHANICAL VENTILATION EQUIPMENT, FURNACE MODIFICATION AND ASSOCIATED DUCTING. X I. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION CF MECHANICAL VENTILATION. X 11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF t ECHANICAL VENTILATION AND ARCHITECTURAL MODIFICATIONS. X 1S. INSTALLATION OF SMOKE DETECTORS. X 19. NEW ELECTRICAL PANEL / SERVICE. X 20. KNOB AND TUBE WIRING. X FILE COPY Permit No. b c3 8 8 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: Date: lam2 --23--7(7, City of Tukwila BUILDING DIVISION By: REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SEPARATE PERMIT REQUIRED FOR: CtlIGiechanicai Ilectrical CrPlumbing t as Piping City of Tukwila BUit~.)INO DIVISION SITE AND BUILDING INFORMATION JURISDICTION: Department of' Planning and Development City of Tukwila, WA APPLICABLE CODES: 2009 International Residential Code, International Fire Code, International Mechanical Code 3341401430 ZONING: SF1200 OCCUPANCY: (No Change) SINGLE FAMILY RESIDENCE CONSTRUCTION TYPE: (No Change) V B NON SPRINKLERED LEGAL DESCRIPTION: LOTS 21 AND 22, BLOCK 6, CD. HILLMAN'S MEADOW GARDENS ADDITION TO THE CITY OF SEATTLE, DIVISION NO. 1, ACCORDING TO THE PLAT THEREOF, RECORDED IN VOLUME 12 OF PLATS, PAGE 64, IN KING COUNTY, WASHINGTON. DRAWING INDEX 70.0 TITLE SHEET, PROJECT INFO. A1.0 FLOOR PLANS 4 NOTES A2.0 WINDOW TYPES, SCHEDULE 4 DETAILS A2.1 DOOR TYPES, SCHEDULE 4 DETAILS 422 MISCELLANEOUS DETAILS A23 WINDOW FLASHING DETAILS MID LEGENDS, SCHEDULES, ABBREV., GENERAL NOTES 4 DWG INDEX M2.0 MECHANICAL PLANS AND DETAILS E1,0 FLOOR PLANS AND NOTES PROJECT DIRECTORY KING COUNTY INTL. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA S8I08 Ph: 206. 263. 9233 Fax: 206.296.0190 Contact: Sharyn Parker E-mail: Sharyn.Parkerekingcounty.gov ARCHITECT: S.M. Stemper Architects PLL.C. 4000 Delrldge Way SW, Suite 200 Seattle, WA 98106 Ph: 206. 624. 2111 Fax: 206.624.2913 Contact: Jerry Osborn, Melody LeungE-mail: jerryesmstemper.com melodyesmstemper.com ACOUSTICAL ENGINEER SSA Acoustics 222 Etruria Street, Suite 100 Seattle WA 98109 Ph: 206. 839. 0819 Fax: 206. 539. 0524 Contact: Mohamed Alt Allaoua E-mail: mohamedessaacoustics.com MECHANICAL ENGINEER: The Greenbusch Group 1900 West Nickerson St., Suite 201 Seattle, WA 98119 Ph: 206. 318. 056e Fax: 206.318.0641 Contact: Dylan Turner E-mail: DylanTegreenbusc com ELECTRICAL ENGINEER: Tres West Engineers 2102 S. 42nd Street, Suite 301 Tacoma, WA 98409 Ph: 253. 412. 3300 Fax: 253.412.3463 Contact: Brent Rollins E-mail: bcretreswest.com REGULATED MATERIALS: PBS Engineering and Environmental 2511 Eastlake Ave. E., Suite 100 Seattle, WA 95102 Ph: 206. 232. 9639 Fax: 206.162.4180 Contact: Tim Ogden E-mail: tim ogdenepbsenvcom DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washington St. *200 Boston, MA 02114 Contact: Tim Fenlason, Cynthia Maeda E-mail: tfenlasonejonespayne.com CMa eda a jon espa yne.com STRUCTURAL ENGINEER Peterson Strehle Martinson 2200 6th Ave, Suite 201 Seattle, WA 98121 Ph: 206. 622. 45130 Fax: 206.622.0422 Contact: Ron Martinson E-mail: ronmepsm-engineers.com R EVi EW.:. D FOR CODE COMPLIANCE APPROVED VICINITY MAP (NTS) DEC 19 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF t UKWILA, S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 024-2973 OCTOBER 16, 2013 0810.03.2586 0 QJ z 0 >- z z z 0 U 0 z AIP NUMBER MPROVEMENTS >- d W 2 W 0 z u_ 3-53-0058-047 DATE OCTOBER 16, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP PROJECT INFORMATION, DRAWING INDEX, DIRECTORY TO.O 0810.03.2586 PERMIT CENTER! DEC 1/2014 vi SPECIAL NOTES: I. CONTRACTOR MUST MAINTAIN EXISTING VENTS IN THE ATTIC SPACE THAT WERE PRESENT PRIOR TO CONSTRUCTION. 2. REFERENCE 2/A22 FOR SMOKE/ CARBON MONOXIDE DETECTOR INSTALLATION DETAIL. 3. SECURITY ALARM SYSTEM PRESENT. COORDINATE WIN HOMEOWNER FOR TEMPORARY DISCONNECTION AND RECONNECTION OF THE SECURITY SYSTEM PRIOR TO START OF WORK 4. THIS RESIDENCE HAS EXISTING DECORATIVE EXTERIOR TRIM. NEW TRIM TO MATCH EXISTING EXTERIOR TRIM PROFILE. REFERENCE 3/A22 FOR PHOTOS. GENERAL NOTES 1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE NE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:30 PM TO 8:30 AM EACH DAY. HOMEOWNERS WILL NAVE COMPLETE ACCESS TO NE RESIDENCE AND ROOMS IN NE RESIDENCE FOR WEEKENDS. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND/OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:30 AM AND 5:30 PM. 6. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 1. ADD SOLID WOOD BLOCKING AT WINDOWS. 8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. 9. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON NE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. 10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 11. ALL WORK AREAS SHALL BE BROOM -CLEANED AT THE END OF EACH WORK DAY. 12. WHERE SOFFITS AND/OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE -CONSTRUCT SHELVING IN COORDINATION WITH SOFFITS AND/OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH A5 CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH NE ADJACENT (E) FINISH COAT. 15. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 18. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION DETAIL ON MISCELLANEOUS DETAILS SHEET. IS. CONTRACTOR 15 TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 20. MAXIMUM POWER OUTAGE IS EIGHT HOURS. POWER MUST 8E PROVIDED AT RESIDENCE BEFORE 8:30 AM. 4 AFTER 5:30 PM. DECK HEAT 3 ` PUMP DININCx ROOM PORCH MAIN FLOOR PLAN 1/4" = 1' LIVING ROOM c PLAN KEYNOTES ODEMOLISH EXISTING WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF: WINDOW SCHEDULE. DEMOLISH EXISTING DOOR, FRAME, CASING, TRIM AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, TRIM, THRESHOLD AND OSTORM DOOR. REF: DOOR SCHEDULE. OREMOVE EXISTING LIGHT FIXTURE TO ALLOW SOFFIT INSTALLATION. COORDINATE WITH ELECTRICAL DOCUMENTS. ODEMOLISH EXTERIOR WALL ASSEMBLY: INSTALL FRESH AIR INTAKE GRILLE. REF: I/A22 FOR DETAIL. REF: MECHANICAL DOCUMENTS. OCOORDINATE INSTALLATION OF NEW THERMOSTAT WITH MECHANICAL DOCUMENTS. O DEMOLISH EXISTING WALL TO ACCOMMODATE MECHANICAL WORK REF: MECHANICAL DOCUMENTS. INSTALL NEW FRAMING AND WALL FINISH TO MATCH EXISTING CONSTRUCTION. EXTEND (E) DRIER EXHAUST VENT TO NORTH CORNER OF BUILDING. ENCLOSE NEW EXHAUST VENT EXTENSION WITH PRE -PAINTED OSHEET METAL FLASHING TO MATCH (E) CONDITIONS. INSTALL NEW SHEET METAL FLASHING PARALLEL WITH (E) EXTERIOR CRAWL SPACE COVER REF. 5/A22 FOR DETAIL. REF: MECHANICAL DOCUMENTS. ACCESS TO SITE AND PARKING I. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. 1'- LEGEND cui ACOUSTICAL WINDOW REFER TO WINDOW SCHEDULE ACOUSTICAL POOR/ STORM DOOR REFER TO DOOR SCHEDULE SECONDARY SLIDING GLASS STORM DOOR REFER TO DOOR SCHEDULE MECHANICAL GRILLE (E) KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REFER TO MECH. FOR UNIT PHOTO DETAIL EXTERIOR ELEVATION PHOTO VIEW NEW THERMOSTAT TIMER SWITCH FOR BLENDED AIR UNIT A. WEST ELEVATION B. NORTH ELEVATION C. EAST ELEVATION D. SOUTH ELEVATION mmrrrm 11WLLIJJ.W E K=1 -1- unnA u REVIEWED FOR CODE COMPLIANCE APPROVED GABLE END VENT BAFFIIE DEC 19 2014 ROOF VENT BAFFLE City of Tukwila BUILDING DIVISION KITCHEN EXHAUST BAFFLE FEATHER TEXTURED CEILING OVER AT A MIN. OF 24" FROM EDGE OF PATCHING. ° : '..; MATCH (E) TEXTURE AND PAINT ATTIC ACCESS PANEL :` =;-CEILING DEMOLITION FOR ATTIC PANEL ..• ; AND WHOLE HOUSE VENT INSTALLATION. ::1 REF. MECH. 4 ELECT. REF. GENERAL NOTE 11 ATTIC INSULATION ATTIC INSULATION DAM INSTALL BATTERY OPERATED SMOKE DETECTORS INSTALL BATTERY OPERATED SMOKE / CARBON MONOXIDE DETECTORS GAS METER RECEIVED CITY OF TUKW NEW SOFFIT CEILING PATCH WORK PERMIT CENT. DEC 1 7 2014 L.k. S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824-2777 • FAX (208) 824-2973 OCTOBER 16, 2013 0810.03.2586 O d ct 0 Ct J Z LJJ Z Z 0 U Z AIP NUMBER z w w 0 0 >- w w w 0 z U_ U Q J Q F- z w 0 ) w 3-53-0058-047 z 0 0 z Q DATE OCTOBER 16, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP FLOOR PLANS CX NOTES AI.O 0810.03.2586 WINDOW TYPES 1. DOUBLE HUNG 2. SLIDER WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE W x H TRIM FINISH INT./ EXT. REMARKS DETAIL SET ,4 DINING ROOM 1 2'-5" x 4'-0" STAIN/STAIN SAFETY GLAZING REQ'D 1/A2.0 B DINING ROOM 1 2'-5" x 4'-0" STAIN/STAIN SAFETY GLAZING REQ'D 1/A2.0 C BEDROOM I 1 2'-5" x 4'-0" STAIN/STAIN 1/A2.0 D BEDROOM I 1 2'-5" x 4'-0" STAIN/STAIN I/42.0 E BEDROOM 1 1 2'-5" x 4'-0" STAIN/STAIN I/42.0 F BEDROOM 2 2 3'-II" x 3'-II" STAIN/STAIN 1/42.0 G KITCHEN 2 3'-II" x 3'-II" STAIN/STAIN 2/A2.0 H LIVING ROOM 1 2'-5" x 4'-0" STAIN/STAIN 1/42.0 I LIVING ROOM 1 2'-5" x 4'-0" STAIN/STAIN I/42.0 J LIVING ROOM 1 2'-5" x 4'-0" STAIN/STAIN 1/A2.0 K LIVING ROOM 1 2'-5" x 4'-0" STAIN/STAIN 1/A2.0 L LIVING ROOM 1 2'-5" x 4'-0" STAIN/STAIN SAFETY GLAZING REQ'D 1/42.0 M LIVING ROOM 1 2'-5" x 4'-0" STAIN/STAIN SAFETY GLAZING REQ'D 1/A2.0 TYPICAL WINDOW SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. 3. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR WINDOWS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. 4. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING DETAIL 'A' ON WINDOW TYPES, SCHEDULE & DETAILS SHEET. PRE -PAINTED, GALV SHEET METAL FLASHING W END CLOSURE. COLOR TO BE SELECTED IN THE FIELD SLOPE I" min. 1 HEMMED EDGE I+ I E END CLOSURE (A) HEAD FLASHING DETAIL TYP. 3=l-0 CUTBACK (E) SIDING FOR INSTALLATION OF NEW WINDOW ASSEMBLY, TRIM, AND FLASHING. PAINT MODIFIED SIDING TO MATCH (E) SIDING. CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF -ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLASHING. TYP AT HEAD AND JAMBS, PRE -PRIMED, GALV SHEET METAL FLASHING W/ END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIPES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY CUTBACK (E) SIDING FOR INSTALLATION OF NEW WINDOW TRIMS AND REATTACHMENT OF (E) SIDING TO WINDOW OPENING FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL WINDOW / NAILING FLANGE OVER SELF ADHERING MEMBRANE PENETRATION FLASHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NALING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK NEW VERTICAL SIDING JOINTS 4 SET NAIL HEADS FLUSH. PAINT MODIFIED SIDING TO MATCH (E) SIDING TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAIL FLANGE (E) WOOD FRAME WALL CONSTRUCTION , • II WINDOW HEAD (E) GWB SELF ADHERING MEMBRANE TOUCH UP PAINT CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM WD. JAMB LINING SEALANT 4 BACKER ROD SHIM 4 FILL GAP W/ err INSULATION 24 GA. GALV. FLASHING OVER LAPPED MIN. 2" BY (E) SIDING. (E) GWB TOUCH UP PAINT WINDOW JAMB TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED CUTBACK (E) SIDING FOR INSTALLATION OF NEW WINDOW ASSEMBLY AND TRIM. REPLACE OR RE INSTALL SIDING. PAINT MODIFIED SIDING TO MATCH (E) SIDING 1 r'' 3/4" CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM IUD JAMB LINING SEALANT 5H1M 4 FILL GAP UJ/ BAiT INSULATION BACKER ROD 4 SEALANT WOOD SILL SOLID WOOD TRIM CONTINUOUS SEALANT, TYP. TOUCH UP PAINT WINDOW SILL 11) SELF -ADHERING MEMBRANE (E) GLIB T-111 SIDING/ WOOD PANELING - DETAIL SET 3"=1'-0" CUTBACK (E) SIDING FOR INSTALLATION OF NEW WINDOW ASSEMBLY, TRIM, AND FLASHING. PAINT MODIFIED SIDING TO MATCH (E) SIDING. CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF -ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) UJALL UNDERLAYMENT OVER PENETRATION FLASHING. TYP AT HEAD AND JAMBS. SET PRE -PAINTED, GALv SHEET METAL FLASHING W/ END CLOSURE UNDER SELF -ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD. REF HEAD FLASHING DETAIL A ON THIS SHEET. TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY PER SCHEDULE CUTBACK (E) SIDING FOR INSTALLATION OF NEW WINDOW TRIMS AND REATTACHMENT OF (E) SIDING TO WINDOW OPENING FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL WINDOW / NAILING FLANGE OVER SELF ADHERING MEMBRANE PENETRATION FLASHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) UJALL UNDERLAYMENT. CAULK NEW VERTICAL SIDING JOINTS 4 SET NAIL HEADS FLUSH. PAINT MODIFIED SIDING TO MATCH (E) SIDING TRIM- MATCH (E) TRIM. PRIME ALL. SIDES AND PAINT TO MATCH (E) TRIM. COLOR.TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY PER SCHEDULE (E) WOOD FRAME WALL CONSTRUCTION• ,` r WINDOW HEAD 0E11 ACOUSTICAL WINDOW ASSEMBLY PER SCHEDULE BACKER ROD 4 SEALANT TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED WINDOW NAILING FIN CUTBACK (E) SIDING FOR INSTALLATION OF NEW WINDOW ASSEMBLY AND TRIM. REPLACE OR RE INSTALL SIDING. PAINT MODIFIED SIDING TO MATCH (E) SIDING 5f)(5 (E) LAMINATE SELF ADHERING MEMBRANE CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM WD JAMB LINING BACKER ROD 4 SEALANT SHIM 4 FILL GAP W/ SATT INSULATION 24 GA. GALV. FLASHING OVER LAPPED MIN. 2" BY (E) SIDING. SELF ADHERING MEMBRANE (E) CABINETRY CONTINUOUS SEALANT, TYP. WINDOW JAMB I I WINDOW SILL SOLID WOOD TRIM WO. JAMB LINING BACKER ROD 4 SEALANT 13/4" SHIM 4 FILL GAP UJ/ BATT INSULATION BACKER 5I REVIEWED FO CODE COMPLIA APPROVED DEC 19 2014 ity of Tukwila DING DIVISI NCE ON WOOD SILL SOLID WOOD TRIM CONTINUOUS SEALANT, TYP. (E) LAMINATE SELF -ADHERING MEMBRANE (E) GLUE RECEIVED CITY OF TUKWI A DEC 1 7 2014 PERMIT CENTER T-111 SIDING/ LAMINATE AND CABINET - DETAIL SET 3"=1'-0" S.M.STEMPER ARCHITECTS. A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 OCTOBER 16, 2013 0810.03.2586 ce O a cc Z 0 Z w Z Z 0 0 0 Z MPROVEMENTS 0 Cw w w 0 z LL w 0 w AIP NUMBER 3-53-0058-047 DATE OCTOBER 16, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER M L&TF DRAWN LB&CP WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.2586 DOOR TYPES A FLUSH SCW HALF -LICE W/ 2 PANELS W/ SAFETY GLAZING B FLUSH SCW W/ SIX PANELS W/ OBSERVATION PORT C EXTERIOR SINGLE LEAF STORM W/ SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE W x H FINISH INT./ EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET 1 LIVING ROOM A 2'-8" x 6'-S" STAIN/ STAIN HUJ-1 / 626 DK-3 JUPITER LOCK-1 I/A2.1 2 KITCHEN B 2'-5" x 6'-8" STAIN/ STAIN HW-1 / 626 DK-3 JUPITER LOCK-1 2/A2.1 3 LIVING ROOM C 2'-8" x 6'-S" I/4,2.1 4 KITCHEN C 2'-5" x 6'-S" 2/A2.1 TYPICAL DOOR SCHEDULE NOTES 1. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER. 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. 4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK. 5. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING DETAIL 'A' ON DOOR TYPES, SCHEDULES & DETAILS SHEET. PRE -PAINTED, GALV SHEET METAL FLASHING WEND CLOSURE. COLOR TO BE SELECTED IN NE FIELD SLOPE HEMMED EDGE E N _J END CLOSURE HEAD FLASHING DETAIL TYP. 3 —1 -0 (E) WOOD FRAME WALL CONSTRUCTION EXISTING SOFFIT AND FRAME WOOD TRIM CONTINUOUS SEALANT BEHIND Z BAR FRAME 2" MN. STORM DOOR PER SCHEDULE CUT BACK (E) SIDING FOR INSTALLATION OF NEW DOOR TRIMS. LIFT (E) WALL UNDERLATENT AND INSTALL SELF ADHERING MEMBRANE PENETRATION FLASHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK NEW VERTICAL SIDING JOINTS 4 SET NAIL HEADS FLUSH. PAINT MODIFIED SIDING 10 MATCH (E) SIDING 24 GA. GALV. FLASHING OVER LAPPED MIN. 2" BY (E) SIDING. SELF ADHERING MEMBRANE CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE KERF FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER-S1RIPPING JAMB BEYOND WOOD DOOR PER SCI-EDULE DOOR SHOE 2" MN. DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP ExISTING FLOOR STRUCTURE SILL IN E3EAD OF SEALANT DOOR HEAD (E) WOOD PANELING CONT. SEALANT, TYP. SOLID WOOD TRIM SHIM 4 FILL GAP W/ BATT INSULATION WOOD FRAME KEIF FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE (E) WD. PANELING CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM SHIM 4 FILL GAF W/ BATT INSULATION DOOR PER SCHEDULE DOORJAMB it) 14 0 DOOR SILL T-111 SIDING/ WOOD PANEL - DETAIL SET 3"=1'-0" (E) WOOD FRAME WALL CONSTRUCTION • .r fr F.... r r EXISTING SOFFIT AND FRAME WOOD TRIM CONTINUOUS SEALANT BEHIND Z BAR FRAME 2" MIN. STORr1 DOOR PER SCHEDULE CUT BACK (E) SIDING FOR INSTALLATION OF NEW DOOR TRIMS. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE PENETRATION FLASHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK NEW VERTICAL SIDING JOINTS 4 SET NAIL HEADS FLUSH. PAINT MODIFIED SIDING TO MATCH (E) SIDING 24 GA. GALV. FLASHING OVER LAPPED MIN. 2" BY (E) SIDING. SELF ADI-ERING MEMBRANE CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE KERF FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER-STRIPPING es5 JAMB BEYOND "'�., '4 r J r• DOOR HEAD DOOR JAMB WOOD DOOR PER SCHEDULE DOOR SHOE 2" MIN. POOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE SILL IN BEAD OF SEALANT DOOR SILL (E) GWB CONt. SEALANT, TYP. SOLID WOOD TRIM SHIM 4 FILL GAP W/ BATT INSULATION 111000 FRAME KERF FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE TOUCH UP PAINT CONTINUOUS SEALANT, TYP. SOLID WOOD TRIM SHIM 4 FILL GAP W/ BATT INSULATION DOOR PER SCHEDULE REVIEWED FOR CODE COMPLIANCE APPROVED DEC 19 2014 City of Tukwila BUILDING DIVISION RECEIVED T-111 SIDING/ GWB PANEL - DETAIL SETTY OF MUM_ 3"= 1'-0" In1717 1 7 2014 S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 OCTOBER 16, 2013 0810.03.2586 ce 0 ce J Z 0 Z w z z 0 0 C� Z AIP NUMBER MPROVEMENTS >- 0 Cw w w O z U_ cn ce 3-53-0058-047 DATE OCTOBER 16, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP DOOR TYPES, SCHEDULE & DETAILS A2.1 CENTEP 0810.03.2586 (E) FRAMING CEILING/ SOFFIT AIR INTAKE DETAIL AT EXTERIOR 3"=1'-0" CUTBACK (E) SIDING FOR INSTALLATION OF VENT FIXTURE AND FLASHING. REPLACE OR RE INSTALL SIDING TO MATCH (E) SIDING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF -ADHERING MEMBRANE PENETRATION FLASHING. LAP (E) WALL UNDERLAYMENT OVER PENETRATION FLASHING. TYP AT HEAD AND JAMBS. PRE -PAINTED, GALV SHEET METAL FLASHING W/ FF. END CAPS UNDER SURFACE MOUNTED REGLET AND CAP FLASHING. PAINT COLOR TO BE SELECTED IN THE FIELD PAINT VENTILATION HOOD, COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION HOOD. REF. MECH.- PAINT INTERIOR W/ ACOUSTICAL DAMPING COMPOUND. SET IN BED OF SEALANT AT EXTERIOR TRIM REPLACEMENT SIDING (E) EXTERIOR WINDOW TRIM MATCH (E) EXTERIOR TRIM PROFILE (E) EXTEIOR WINDOW TRIM TYP. NTS EXISTING CEILING/ FLOOR/ ROOF STRUCTURE 14•-i u5ss CEILING BEST HERE ACCEPTABLE HERE 4"MIN NOTE: REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING. REMOVE ALL PANT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. E SIDE WALL DETECTOR INSTALLATION DETAIL TYP. } 3 = 1 - 0 DUCT DUCTS PER PLAN WITHIN SOFFIT RE: MECHANICAL 2x2 CONT. NAILER %" GUS- PAINT TO MATCH (E) TEXTURE 4 COLOR OF CEILING. SOFFIT DUCT DETAIL 11/2"=1'-0" (E) BUILDING EDGE PRE -PAINTED, 24 GA. GALV SHEET METAL FLASHING W/ FF. END CAP UNDER SURFACE MOUNTED REGLET AND CAP FLASHING. PAINT COLOR TO BE SELECTED IN THE HELD NEW EXHAUST PER MECH. (E) BOTTOM EDGE OF BUILDING (E) CRAWL SPACE COVER SLOPE ENCLOSE DUCTS TIGHTLY, OR TERMINATE EDGE W/ ADJ ARCHITECTURAL FEATURES PER PLAN. COORDINATE SOFFIT DIMENSIONS WITH MECHANICAL (E) IUD FRAME WALL ASSEMBLY EXHAUST EXTENSION/ FLASHING DETAIL REVIEWED FOR CODE COMPLIANCE APPROVED DEC 19 2014 City of Tukwila BUILDING DIVISION R :CEFVED CITY OF TUKWILA DEC 1 7 2014 S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824-2777 • FAX (206) 624-2973 OCTOBER 16, 2013 0810.03.2586 0 CL ce J Z Z W I-- Z Z O 0 C.9 Z AIP NUMBER MPROVEMENTS >- 0 w w w (!) 0 Z LL J F- w 0 (!) w 3-53-0058-047 0 F- 0 Z DATE OCTOBER 16, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP MISC. DETAILS A2.2 PERMIT CENTER 0810.03.2586 LIFT (E) WALL UNDERLAYMENT AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD BUTTERFLY COMERS, TYP. LAP SILL FLASHING MEMBRANE 2-1/2" OVER (E) BLDG. PAPER AT SILL. EXTEND I i" BEYOND RO. AT EA. END OF SILL. UNDERLAYMENT AT SILL NOTE: CUT (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. MEMBRANE FLASHING AT SILL (E) SHEATHING CUT SILL FLASHING MEMBRANE TO EDGE OF RO. AS SHOWN. ADHERE FLASHING MEMBRANE TO OUTSIDE FACE OF WALL SHEATHING 1i" MIN BUTTERFLY CORNER FLASHING SCALE: NTS LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD. (E) SIDING NOT SHOWN FOR CLARITY. MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. WINDOW NAIL FLANGE: EMBED WINDOW HEAD AND JAMB NAIL FLANGE IN SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING MEMBRANE AND WINDOW FLANGES. SEALANT SHOULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SHOULD FILL FLANGE NAIL HOLES. REMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE AT WINDOW SILL (E) WALL UNDERLAYMENT AT SILL. NOTE: CUT (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT 51-1OUN FOR CLARITY. 4" TY INSTALL 24 GA. GALV. FLASHING OVER MEMBRANE FLASHING LAPPED MIN. 2" BY (E) SIDING ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES 4� WINDOW MEMBRANE INSTALLATION SCALE: NTS REMOVED EDGE OF (E) SIDING, SHOU.N D I AGRAMATI CALLY. (E) SIDING NOT SHOWN FOR CLARITY. LAY (E) WALL UNDERLAYMENT BACK DOWN OVER FLANGE FLASHING AT JAMBS r-- WHERE REG (E) WALL UNDERLAYr HEAD TO P FOR INSTAL HEAD FLAS MEMBRANE WINDOW T BEND ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. (E) SHEATHING UIRED, TRIM 'TENT AT REPARE LATION OF RING AND (FOLL•11 PS). L J HEAD FLASHING PREPARATION SCALE: NTS (E) WALL UNDERLAYMENT INSTALL SHT. METAL HEAD FLASHING UNDER (E) BLDG PAPER TRIMMED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. CUT JAMB FLASHING MEMBRANE TO EDGE OF WINDOW OPENING AS SHOWN. EXTEND 1-1/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL. ADHERE FLASHING MEMBRANE TO OUTSIDE FACE OF WALL SHEATHI1'G 2 1/2" TYP MEMBRANE FLASHING AT JAMB SCALE: NTS — INSTALL JAMB FLANGE FLASHING MEMBRANE OVER WINDOW NAILING FLANGE AND FLASHING. MEMBRANE FLASHING AT JAMB SCALE: NTS ALLOW 1/5" BETWEEN FL BOT. EDGE SIDING. HEAD FLASHING INSTALLATION LEARANCE WING AND (E) SCALE: NTS (E) WALL UNDERLAYMENT INSTALL HEAD 11/2" TYP 1 1/2" TYP MEMBRANE FLASHING AT HEAD CUT HEAD FLASHING MEMBRANE TO EDGE OF WINDOW OPENING AS SHOWN. EXTEND 1-1/2" BEYOND RO. AT HEAD AND JAMBS. ADHERE PENETRATION FLASHING MEMBRANE TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) SCALE: NTS FLANGE FLASHING MEMBRANE OVER WINDOW NAILING FLANGE AND FLASHING. L L J I WINDOW FLASHING INSTALLATION SCALE: NTS WOOD TRIM INSTALLATION SHEET METAL HEAD FLASHING (E) SIDING (E) BLDG. PAPER BENEATH SIDING SCALE: NTS INSTALL WD. TRIM. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. J CHANNEL TRIM REQUIRED FOR VINYL SIDING INSTALLATION. LEAVE I/4"-3/8" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. GENERAL NOTES: 1: MEMBRANE FLASHING IS SPECIFIED IN 01 62 00 AS "SELF ADHEARING MEMBRANE FLASHING" TYPICALLY REFERED TO AS "PEEL AND STICK" 2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5 AND 6" REFER TO MEMBRANE INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "1 AND 5" REFER TO SHEET METAL HEAD FLASHING. 5: DETAIL 9 REFERS TO WOOD TRIM AND CAULK JOINTS. TRIM TYPE WILL VARY DEPENDING ON (E) SIDING MATERIAL, FINAL TRIM FINISH SELECTED BY HOMEOWNER REVIEWED FOR CODE COMPLIANCE APPROVED DEC 19 2014 City of Tukwila BUILDING DIVISION D11,F(nssi RECEIVED CITY OF TUKWILA DEC 1 7 2014 PERM' CENTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 OCTOBER 16, 2013 MPROVEMENTS 0810.03.2586 AIP NUMBER 3-53-0058-047 DATE OCTOBER 16, 2013 ISSUED 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML&TF DRAWN LB&CP WINDOW FLASHING DETAILS A2.3 0810.03.2586 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG M FG NC NIC NFPA NG NO N TS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC SRC TDH TOD TPD TSP TYP V VD VTR W WB w/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS SEATTLE RESIDENTIAL CODE TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL XX ABBR DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW OR XX EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK 0 ROUND DUCT DIAMETER X/Y X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION Y/ A Q EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MECHANICAL PLANS AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOVIN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 4'-0" AFF. UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 10'-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 3'-0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. SYMBOL SG-X XXX ABBR DN DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DN DUCT OFFSET DOWN IN FLOW DIRECTION + UP I + UP S f >CI 0-0 041-. OR EQUIP ID# NG IyI • D 0 D"a VD RA/EA RG SA SA RA/EA SD DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE/DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL/ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION DESCRIPTION VOLTS PH 23 26 23 26 N/A 23 26 N/A - MOTOR OPERATED DAMPER 24 1 X X X 1,2 - THERMOSTAT 24 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH WALL CAP SCHEDULE MARK LOCATION CFM AIR VELOCITY FPM STATIC PRESSURE SIZE REMARKS WC-1 EXTERIOR 90 337 <.08"WG 7"0 1,2 REMARKS: 1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN 2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT A. OR APPROVED EQUAL GRILLE AND DIFFUSER SCHEDULE MARK CFM STATIC PRESSURE INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # REMARKS RG-1 I - <.OE" 24"x18" 24"x18" - 80 1,2,3,4,6,7 REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2 PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 3. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 4. BASIS OF DESIGN: PRICE A. OR APPROVED EQUAL. 5. BASIS OF DESIGN: SHOEMAKER A. OR APPROVED EQUAL. 6. PROVIDE WITH AN OPPOSED BLADE DAMPER 7. GRILLE SHALL BE RATED FOR 1200 CFM MIN. WITH CORE VELOCITY <500 FPM AND NC VALUE <20. FIELD VERIFY DIMENSIONS PRIOR TO ORDERING. WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.2586 1162 2 90 CFM 90 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51-51-1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION MIN VALUE NOTES ON ROOF OR ON EXTERIOR OF BUILDING R-8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR/CEILING R-8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R-8 1,3 IN CEMENT SLAB OR IN GROUND R-5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR/CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO UNCONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO CONDITIONED AIR. 3. REFER TO WASHINGTON STATE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. 1) THERMOSTAT HOURS OF OPERATION SET FURNACE THERMOSTAT TO OPERATE 1 OF EVERY 2 HOURS. MECHANICAL VENTILATION CALCULATION PER WAC 51-51, SECTION M1508.3 QF = QR / (&EGR X F) QR = (FROM TABLE 1508.2) 45_ &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2 QF = 45 / (1 X 1/2) = 90 CFM pARAre APp MI1�AND QED b3bob RECEIVED CITY OF TUKWILA DEC 17 2014 PERMIT CENTER S.M. STEMPER ARCHITECTS A Frol'mealonni Malted l,tobllfly Company 4000 DELRLBGE WAY SW SUITE 200 • SEATVLE, WA 90106 (206) 624-2777 • FAX (206) 624-2973 THE GREENBUSCH GROUP, INC ACOUSTICAL, AUGIO VIDEO do MECHANICAL ENGINEERING 1900 WEST N STREET SUITE 201 SEATTLE, WA 99119 (206) 370-0569 (209) 376-0041 FAX 0810 03.2586 0 z 0 H z w z 0 0 z se EDY IMPROVEMENTS w w O z W Ct AIP NUMBER 3-53-0058-047 TUKWILA WASHINGTON DATE 10/16/2013 ISSUED 100%, CD PROJECT ENGINEER DT PROJECT MANAGER DT DRAWN JA LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX EXTEND (E)EXHAUST VENT TO PROVIDE 10' MIN. HORIZONTAL SEPARATION FROM WC-1. ENCLOSE WITH PRE —PAINTED SHEET METAL FLASHING FOR VISUAL SCREENING. REFER TO ARCHITECTURAL. SEE BATH (E)SG (E)SG 1-- 0 0 vi Q BEDROOM BEDROOM 1 RELOCATE (E)LIGHT FIXTURE (E)SG CLOS. !. x eb< (E)SG PATIO WC-1 90 NEAT T RG-1 CUT & PATCH STUD WALL REQUIRED TO INSTALL RETURN AIR GRILLE. DINING ROOM SEE MAIN FLOOR MECHANICAL PLAN SCALE: 1/4" = 1'-0" ATTIC POC RG-1 —W FLOOR HEAT PUMP (E)SUPPLY MOD, INTERLOCK TO FURNACE, TYP KCHEN E (E)SG PATIO (E)SG LIVING ROOM (E)SG (E)SG x OUTSIDE AIR DUCT, SIZE AND ROUTE PER PLAN OUTSIDE AIR TO FURNACE ELEVATION SCALE: NONE (E)SIDING SHEET METAL FLASHING 2X2 BLOCKING WALL CAP 2X2 BLOCKING II II 2X BLOCKING HARD DUCT PER PLAN JOIST 2X BLOCKING NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL DETAIL DRAWINGS. WALL CAP DETAIL SCALE: NONE DRAWING NOTES: 1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM. 2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51-51 SECTION M1507.3.5.3. 3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY WAC 51-51, SECTION M1507.3.2.(CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY —CONSUMING APPLIANCES). COORDINATE FINAL TIME SETTING WITH PROJECT REPRESENTATIVE. 4. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK—OUT WORK HAS BEEN COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE FOLLOWING: A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING AIR UNIT SYSTEM(S) WITH NEW FILTERS. FLAG NOTES: CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. REVISE EXISTING WSEC RA03.1.1 COMPLIANT THERMOSTAT. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51-51 1507.3.2.5.8. MODIFY WIRING AS REQUIRED BY DRAWING NOTE #3. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4 FEET OF FURNACE RETURN INLET PER WAC 51-51 M1507.3.5.1. FIELD FABRICATE NEW RETURN AREA PLENUM. FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION. REMOVE OR RELOCATE (E) LIGHT FIXTURE. REFER TO ELECTRICAL. WALL WEATHER SEALANT 24 GA. MIN. PRE —PAINTED SHEET METAL. REFER TO ARCHITECTURAL DETAIL DRAWINGS. LAUNDRY EXHAUST GALVANIZED METAL STRAP LAUNDRY EXHAUST FLASHING SCALE: NONE 1 D') RECEIVED CITY OF TUKWILA, DEC 1 7 2014 PERM CENTER S.M. STEMPER ARCHITECTS A Protemional Limited Llebllily Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (200) 624-2777 FAX (206) 624-2973 • HE GREENBUSCH GROUP, INC 0006990410 ACOUSTIC/L. AUDIO VIDEO & MECHANICAL ENGINEERING 1000 WEST STREET SUITE 201 SEAM. WA 98116 (206) 376-0569 (206) 376-0641 FAX 0810.03.2586 ce 0 a ce 0 z Z LLI 1- 0 U 0 Z RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS AIP NUMBER 3-53-0058-047 DATE 10/16/2013 ISSUED 100% CD PROJECT ENGINEER DT PROJECT MANAGER DT DRAWN JA MECHANICAL PLANS AND DETAILS rr LEGEND ELECTRICAL SYMBOL DESCRIPTION SYMBOL DESCRIPTION G LIGHTING OR POWER PANEL EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. ® BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2"C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND. } INDICATES ISOLATED GROUND. 1111/ 111111 4 ❑' la ®D DAMPER CONNECTION - - - - NON -FUSED DISCONNECT SWITCH o MAST, WEATHERHEAD TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS BRANCH CIRCUIT HOME RUN SMOKE DETECTOR ELECTRICAL METER 1 TIMER OPERATED SWITCH E] AERIAL SERVICE CONDUCTORS, COORDINATE WITH U11LITY. 0 THERMOSTAT — - — CEILING MOUNTED FIRE ALARM -VISUAL STROBE LIGHT ® LINE VOLTAGE FIRE ALARM SMOKE/CARBON MONOXIDE DETECTOR ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8:00 AM TO 5:00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER 5: 00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH —IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. ELECTRICAL PLAN NOTES O PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE. O PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS. 0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING SPECIFICATIONS FOR SWITCH. � REMOVE AND RELOCATE EXISTING LIGHT FIXTURE TO ALLOW FOR INSTALLATION OF NEW SOFFIT. REFER TO ARCHITECTURAL DRAWINGS. RE -INSTALL FIXTURE AFTER SOFFIT INSTALLATION. INTERCEPT AND EXTEND WIRING AS REQUIRED. FIELD COORDINATE FOR BEST LOCATION OF FIXTURE. TO HEAT PUMP POWER SUPPLY TO HEAT PUMP DAMPER PIN NG ROOM MAIN FLOOR PLAN 1/4" = 1' iw l II 771 IV NG tea, NORTH RECER, ED CITY OF TUKWILA DEC 1 7 2014 SEPARATE PERMIT CENTER ERM►TAND APPROVAL REQUIRED S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 0810.03.2586 MPROVEMENTS >- 0 w w w 0 Z C.) W W AIP NUMBER 3-53-0058-047 DATE October 16, 2013 ISSUED 100% PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN SCM FLOOR PLANS NOTES E1.0 0810.03.2586