HomeMy WebLinkAboutPermit D14-0395 - INTERLINE - RAMPINTERUNE RAMP 1177 ANDOVER PARK E EXPIRED 09/26/15 D14-0395 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov DEVELOPMENT PERMIT 3523049097 Permit Number: D14-0395 1177 ANDOVER PARK W Project Name: INTERLINE RAMP Issue Date: 3/5/2015 Permit Expires On: 9/1/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: CWWA SOUTHCENTER 4 LLC PO BOX B-3879 C/0 EQUITY OFFICE MGMT LLC, CHICAGO, WA, 60690 DAVID KEHLE, ARCHITECT 1913 BONAIR DR SW , SEATTLE, WA, 98116 D M P CONST 3819 S 239TH ST , KENT, WA, 98032 DMPCO**065J1 OWNER FUNDED Phone: (206) 433-8997 Phone: (206) 824-8970 Expiration Date: 4/30/2015 DESCRIPTION OF WORK: CONSTRUCT EXTERIOR CONCRETE RAMP AND REMOVE EXISTING ASPHALT Project Valuation: $13,500.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: IIIB Electrical Service Provided by: TUKWILA FIRE SERVICE Fees Collected: $624.50 Occupancy per IBC: S-1 Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: 0370. VAS I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: NAM—atitild.J Print Name: l..h Date: l laOR This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: The special inspections and verifications for concrete construction shall be as required by IBC Chapter 17, Table 1705.3. 5: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 6: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 7: Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with the recommendations given in the soils report. Special inspection is required. 8: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 9: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 10: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 11: Preparation before concrete placement: Water shall be removed from place of deposit before concrete is placed unless a tremie is to be used or unless otherwise permitted by the building official. All debris and ice shall be removed from spaces to be occupied by concrete. 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: Prior to construction, all utilities in the vicinity shall be field located. NOTE: For City of Tukwila utility locates, call 811 or 1-800-424-5555. 14: Any material spilled onto any street shall be cleaned up immediately. 15: Temporary erosion control measures shall be implemented as the first order of business to prevent sedimentation off -site or into existing drainage facilities. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0301 CONCRETE SLAB 0201 FOOTING 0200 FOUNDATION WALL 4000 SI-CONCRETE CONST 4046 SI-EPDXY/EXP CONC 4035 SI-SOILS CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htth: vv.1ilkyitaw. A.uot Building Permit No. Project No. oic Date Application Accepted: Date Application Expires: 1I— 20 t 77 o (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: II 11 /4 ,jG2' 13g11G�I Tenant Name: 1u IGti Litie T�i'Fr PROPERTY OWNER Name: �1 6/6i'-�/ l u,� t I W 1ntw Address: 0,,I N v13r3171 f, 4 City:loam Ito State: Zi :ci CONTACT PERSON — person receiving all project communication Name: a,1vi_ btIh, Address: Ki t to4gyp .� "►! City we Staab&ZiFII Li Phone: fog* * p�Pq�' Fax:tote ... g 1 �� Emai1:aja e4tceliteAr&1%• %w GENERAL CONTRACTOR INFORMATION Company Name:� Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: King Co Assessor's Tax No.: l',7 t l 7 4 Suite Number: Floor: 1 New Tenant: 0 Yes ..No ARCHITECT OF RECORD Company Name:am Nue.i kaµl i. Architect Name: aila � _. lics Address: tc`ce1a pW City:t am., „ State • Zip: li te Phone:1 _ _ } 33 . 4 Fax: /lap_ tittto _g2,_1 o Email: 12bel „ Q 414441Qeiral. Com ENGINEER OF RECORD Company Name: (,-j'_ ovxv_itt Engineer Name: `t I`� { iaG a1 � Address: t City: # State7�6 • _lllopl8 Zipii1 Phone:. .4 4t ux: fop. wi .s2.13 Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW r'✓�,,19.27.095) Name: �ryr 5`jr ���i -` ,a'll Io r` Address: City: State: Zip: H:\Applications\ Forms -Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ Describe the scope of work (please provide detailed information): Existing Building Valuation: $ eftGi 1LU 2d Cpustrzuct. mit32 2,. Caw& Vlaiir a Verbie taroP16t,1" Will there be new rack storage? ❑ Yes yt.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing .*terier Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC l'Floor 181 / /' RRl-42 1 2nd Floor 3rd Floor Floors thou Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, rovide the following: Lot Area (sq ft): Ilo Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal o1w,n_` err lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 12r/ 147 1IiG 7 Compact: ° Handicap: Will there be a change in use? ❑ Yes No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: '0 Sprinklers ❑ Automatic Fire Alarm ❑ None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No 1f 'Yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line12011 Applicatons\Pemm Appliemion Revised - 8-9-n.doc Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES - Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 R OR . 0 RIZED AGENT: Signature: � Date: tZ'?A Print Name: �p14 �GHM Mailing Address: 141 (19 ftltie. t Z *8/ Day Telephone400- 3 4 - Os"t111tLo City State Zip H:\Applications\FomerApplications On Line\20l 1 Applications\pennit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $387.44 D14-0395 Address: 1177 ANDOVER PARK W Apn: 3523049097 $387.44 DEVELOPMENT $369.20 PERMIT FEE R000.322.100.00.00 0.00 $364.70 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $18.24 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R4749 R000.322.900.04.00 0.00 $18.24 $387.44 Date Paid: Thursday, March 05, 2015 Paid By: DMP CONSTRUCTION Pay Method: CHECK 4394 Printed: Thursday, March 05, 2015 10:26 AM 1 of 1 CI ® SYSTEMS DESCRIPTIONS ACCOUNT QUANTITY I PAID PermitTRAK $237.06 D14-0395 Address: 1177 ANDOVER PARK W Apn: 3523049097 $237.06 DEVELOPMENT $237.06 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R3864 R000.345.830.00.00 0.00 $237.06 $237.06 Date Paid: Tuesday, December 30, 2014 Paid By: DAVID EKEHLE, ARCHITECT Pay Method: CREDIT CARD 015854 Printed: Tuesday, December 30, 2014 12:19 PM 1 of 1 ��YPISYSTEMS INSPECTION RECORD Retain a copy with permit •SPEC ON NO. PERMIT NO. CITY OF OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Prohct: 6,q/PL114 Type Address: ' , 1177 it4.6ver Tczt)tcv Date Called: Special Instructions: 4_n4 --E 3,,Date Wa- 13- a.m. Pan. Requester: AO V K /66 Phone No: Iv0 Corrections required prior to approval. Approved per applicable codes. CA'A5kc‘ irS Vfr CtatOrbe=-4 Q r-dact-v- frt" ot 5 rcuf, COMMENTS: PrQ41 „AIM- (9, c Skaio ‘&.r Led Arik 56( (is k<....i inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit IN ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 PIM o Project:— c likfrer tc Kt itsv41) Type of Inspectipni f-t-a(AQ(ckitidp, wet (I 'Address: ( (77 tfrldover Aqui Date Called. Special Instructions: #405. AAA Date Wanted: .../ ir. -3 - >-( a.m. p.m. Requester: G-A4( CwA5f, Phane No' - 2-76 - 3 7._/ 7 Approved per applicable codes. Corrections required prior to approval. CO MENTS: $t cqr- P--- rtfeyg€1 Inspector: 410:44.000* REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection, INSPECTION RECORD Retain a copy with permit IN5P CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 poi-07n- Type of lnspction: frr- / Address: 1 ( 77 'WO ti eAr rartio. Date Called: Special Instructions: itif4 Date Wanted: 3-0 (7 --- a.m. P.m. Requester: PqAtAr rfr Phone No: ele6 — 7,76 — 37-A 7 VAI Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Lq,b ire,op-t ir&f CC:N te(C_ nspector: Date3 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. CT ENGINEERING INC. VELE COPY' n.�r*rr..A01ei) STRUCTURAL CALCULATIONS Tenant Improvement - Vehicular Ramp 1177 Andover Part West Tukwila, WA Architect: David Kehle Architect 180 Nickerson St. Suite 302 Seattle, WA 98109 (206)285-4512(V) (206) 285-0618(F) Scope of Work: New concrete ramp from exterior grade to floor slab, 4'-0" total raise. The side walls will be reinforced concrete, the ramp slab will be concrete on fill. Code: IBC Loads: Slab Structural Engineers 2012 edition 250 PSF (vehicular drive ways) REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 3 2015 Ci of Tukwila BUILDING DIVISION 12/29/2014 RECEIVED CITY OF TUKWILA DEC 3 0 2014 PEfMT CENTER C T ENGINEERING � INC. Project }1�WAA.c0 %,71 kevtNe,"V E'[z Oi�L Date: 1 2g t LI FAX; Client: Page Number: 1 (206) 285.0618 180 Nickerson St. Suite 302 Seattle, WA 98109 (204)285-4512 Structural Engineers Design Maps Summary Report Page 1 of 2 MN Design Maps Summary Report User -Specified Input Report Title Andover Park Mon December 29, 2014 15:54:49 UTC Building Code Reference Document 2012 International Building Code (which utilizes USGS hazard data available In 2008) Site Coordinates 47.445°N, 122.258°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/I11 E.T apquest USGS-Provided Output Ss m 1.439 g S1 = 0.536 g SeaT ODe' Moines SMs SMi = 1.439 g 0.804 g East Renton':'S 4Htglilands`` C�• •Kenti iztfi+4i te21 . j a MaisQuest Sox = 0.959 g Sol = 0.536 g For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. MCER Response Spectrum 1.65 1.50 1,25 1.20 1.05 0,20 0.75 0.G0 0.45 0.30 0.15 0.00 0.00 0.20 0 a0 0 60 0 SO 1 00 1.20 L.40 1.60 Period, T (sec) 1.80 1 2.00 1.10 1.00 0.90 0.80 0.70 a 0.50 0.40 0.20 0.20 0.10 0.00 Design Response Spectrum 0.00 0.20 0.40 0.40 0.90 1.00 1.20 1.40 1.00 1.00 2.00 Period, T (sec) http://ehp2-earthquake.wr.usgs. gov/desigmnaps/us/summary.php?template=minimal&lati... 12/29/2014 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 R3 Envelope Summary ENV -SUM 2012 Washington State Energy Code Compliance Forms for Commercial. Groun R1 anti > 1 M•nru R2 & R3 Revised June 2013 Project Info Project Address 'r E.-, Mp . Date v2„2ci.14 1 I. 71 Ascriez. VatG,w - For Building Department Use - M! ton,„„,„ Applicant Name: aki Iv 1)E416 ,P'twKi 1� 1 Applicant Address: Alto ' �td pp ,A/ 'f Ali wWA "CI No i i e. Applicant Phone: ,A.. _ q- . Project Description ■ New Building ■ Addition V Alteration ■ Change of Occupancy/Conditioning Compliance Path ■ Prescriptive ■ Component Performance ■ Total Building Performance Occupancy Group 0 Commercial 0 Group R (R-1 & > 3 story R-2 and R-3) Climate Zone 0 Climate Zone 0 Climate Zone I1 ( See WSEC 301.1 for county list) Vertical Fenestration and Skylight Area Calculation If complying via the Prescriptive path, provide values for vertical fenestration, skylights, gross walls and roof. If complying via the Component Performance path, these values are auto- filled by the ENV-UA form and cannot be edited here. Total Vertical Gross Exterior Fenestration Above Grade % Vertical (rough opening) divided by Wall Area times 100 equals Fenestration X 100 Gross Exterior Total Skylight divided by Roof Area times 1QQequals % Skylight _ 1Oi cE-17_ l) Maximum Prescriptive Fenestration Area Vertical m",- %-ty,Vip LIAt11CL Fenestration "°�• ".,Iiil;`='D Skylights JAN 2 3 2015 t 50% Floor Area in DLZ 0 More than 50% of the floor area in daylight zone per C4 2.3.1. 1cii* r "1S r. .v Ol T(eV- , •, Semi -Heated Path `k�Lu1iyC, "' DiVi . --' 1 --. --� and has a max. heating system for requirements. other conditioned spaces- provide or Component Performance compliance spaces shall comply with ■ Project has semi -heated areas as defined per C402.1.4 • Applying wall exception to semi -heated areas 1. To be deemed semi -heated the area is heated but not cooled, output capacity between 3.4 - 8 Btuhlft2. Refer to C402.1.4 2. Semi -heated spaces shall be documented separately from separate compliance forms for each conditioned area type. 3. Semi -heated spaces may comply under the Prescriptive path. 4.Envelope elements separating semi -heated from other conditioned thermal envelope requirements for an exterior wall. Refrigerated Spaces freezer of Occupancy/Conditioning only. Compliance documentation for in the ENV -PRESCRIPTIVE form. Refer ❑ Walk-in cooler ■ Walk-in • Refrigerated Warehouse Cooler • Change Refrigerated spaces shall comply under the Prescriptive Path these areas may be combined with non -refrigerated areas Mixed Occupancy and/or Space Conditioning FIB E VED CITY OF TUKWIL A DES 3 0 2014 Project includes more than one occupancy type and/or level compliance forms may be required. Select all that apply to scope of space conditioning. Multiple of project: 0 Refrigerated Space 0 Low Energy* and compliance forms for ■ Commercial ■ Group R1 or >3 story R2/R3 0 Fully Conditioned ■ Semi -Heated ■ Group R2/R3 < 3 story "Low energy areas are exempt from all thermal envelope provisions these areas are not required. Refer to C101.5.2 for exemption. FibinvetiotwEF5 ewlvtict Nyetivfe tL'1 3cc 2012 Washington State Energy Code Compliance Formsfor Commercial, Group RI, and > 3 story R2 and R3 Interior Lighting Summary LGT-SUM 2012 Washington State Energy Code Compliance Forms for Commercial, Group RI, and > 3 story R2 and R3 Revised June 2013 Project Info Project Address iK1abige, arty _ , (f• Date ', I 'z . 1111 r ViCZN 14Vi For Building Depa ent Use • Applicant Name: V tiO oey,j.i cl Applicant Address: ibl Q Pa Ai rr PP. f 1t b, Applicant Phone: 3 . c Project Description Alteration • New Building • Addition • Plans Included Lighting Compliance Path 0 Lighting Power Density Calculations 0 Total Building Performance (if Total Building Performance then only LGT-CHK is required.) Interior Lighting Compliance Option 0 Building Area Method Q. Space -by -space Method Interior Lighting System Description Briefly describe lighting system type and features. Additions and Change of Space Use (C101.4.3 & C101.4.4) • Addition area or Change of Space Use area complies with all applicable provisions as stand alone project area or Change of Space Use area is combined with existing building lighting systems to demonstrate with all applicable provisions Building Area Method (LTG-INT-BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum and proposed (including existing if applicable) lighting wattage of Addition or Change of Use scope. Provide applicable lighting per C405.2 and commissioning of lighting controls per C405.13. • Addition compliance Provide allowed controls Alterations, Renovations and Repairs (C101.4.3.1) ❑ 60% or Provide allowed more of luminaires in space replaced Building Area Method (LTG-INT-BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum and proposed (including existing) lighting wattage of project scope 60% of luminaires in space replaced Space -by -space Method (LTG-1NT-SPACE) Compliance Form. Document existing total wattage in space and proposed existing) lighting wattage of project scope • Less than Provide (including ballast replacement within existing luminaires only — existing total interior building wattage not increased • Lamp and/or installed to serve added fixtures and/or fixtures relocated to new circuit applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific controls (C405.2.3), and commissioning of lighting controls per C405.13 • New wiring Provide application moved lighting panel all applicable lighting controls as noted for New Wiring, automatic time switch controls (C405.2.2.1), and commissioning of controls per C405.13. • • New or Provide lighting ❑ Space is reconfigured - luminaires unchanged or moved only Provide all applicable lighting controls as noted for New wring and commissioning of lighting controls per C405.13. No changes are being made to the interior lighting and space use not changed. City of Tukwila Department of Community Development 8/6/2015 DAVID KEHLE, ARCHITECT 1913 BONAIR DR SW SEATTLE, WA 98116 RE: Permit No. D14-0395 INTERLINE RAMP 1177 ANDOVER PK W Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 9/26/2015. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 9/26/2015, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D14-0395 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0395 DATE: 12/30/14 PROJECT NAME: INTERLINE RAMP SITE ADDRESS: 1177 ANDOVER PK W X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Att)Cd 1=3—'1 t-\)+-ts-- Building Division Fire Prevention ® Planning Division 110 Public Works n< e/ 14,0 - 1`) _ LIMINARY REVIEW: Not Applicable n (no approval/review required) Structural Permit Coordinator DATE: 01/01/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 01/29/15 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff initials: 12/18/2013 D M P CONST Home Inicio en Espanol Contact 'Search L&I Page 1 of 2 A-Z, Index Help My Secure MI Safety Claims & Insurance Workplace Rights Trades & Licensing 0Washington State Department of Labor & Industries D M P CONST Owner or tradesperson POTTS, DANNY M Principals POTTS, DANNY M, OWNER Doing business as D M P CONST WA UBI No. 601 540 788 3819 S 239TH ST KENT, WA98032 206-824-8970 KING County Business type Individual License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. DMPCO**065J1 Effective — expiration 04/21/1994— 04/30/2015 Bond Lexon Ins Co Bond account no. 9805486 $12,000.00 Received by L&I Effective date 04/19/2011 04/18/2011 Expiration date Until Canceled Bond history Insurance ........._..._._........ American States Insurance Co Policy no. 01 CG84177700 $1,000,000.00 Received by L&I Effective date 06/30/2014 07/02/2014 Expiration date 07/02/2015 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations .............. . ......................... No license violations during the previous 6 year period. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601540788&LIC=DMPCO**065J1&SAW= 03/05/2015 BUILDING AND SITE STATISTICS: SCOPE OF WORK: ENERGY CODE MIXED -USE, NON -SEPARATED USES (SECTION 601): TYPE OF CONSTRUCTION: 111-B (FULLY SPRINKLED) 501.3 IVO STORY, BUILDING IS SURROUNDED BY 60' OPEN SPACE ALL SIDES.(8,51'i USES) UNLIMITED AREA AND UN SEPARATED USES ASSE55OR PARCEL NUM 3ER 9432'35114 LEGAL DESCRIPTION PARCEL B: 352304 91 POR OF SW 1/4 OF SE 1/4 OF SEC 26-23-4 4 FOR NW 1/4 OF NE 1/4 OF SEC 35-23-4 BEG AT NE COR OF NW 1/4 OF NE 1/4 SEC 35 TH N S1-44-08 W 30 FT TH N I-41-29 E ALG W LN OF ANDOVER PARK 111115.66 FT TH N 81-55-02 W 110.1 FT TO TPOB TH 5 81-55-02 E 4401 FT TH S 1-41-29 W 114.61 FT TO AN ANGLE PT THEREIN TH 51-51-39 W 662.19 FT TH N 81-55-02 W 4401 FT TH NLY IN A STRAIGHT LN 191 FT TO TPOB LESS WLY 216.6 FT EXISTING TENANT SPACE NO WORK _ 1}-.--H .-... •1f" -" 1 BUILDING CODE: ZONING: SITE AREA: APPROX EXISTING BLDG. (OFFICE 10,618, LIME 65232) TENANT SPACE: 1023 SP. OFFICE. AREA OF WORK: 300 SF. EXTERIOR. RAMP OCCUPANCY GROUPS AND LOADS: B (OFFICE) 1,810 SF. / 100 ■ S-1(WAREHOUSE) 16,544 SF. / 500 ■ TOTAL. OCCUPANTS IBC 2012 W/ WA STATE AMENDMENTS TUC (TUKWILA URBAN CENTER) 215,015 SF. (494 AC) 950550 SF. 10913 SF 13 OCCUPANTS 33 OCCUPANTS 52 OCCIPANTS TYPE OF CONSTRUCTION: III-5 (FULLY SPRINKLED) PARKING: NO CHANGES REQUIRED PARKING :OVERALL BUILDING OFFICE: 8,318.4 SF. a 3.0/1000 : 25.0 FACES RETAIL: 14,641.0 SF. a 2.5/1000 = 36.6 SPACES WHSE: 63,555.6 SF. a 1.0/2000 = 41.8 FACES 103 SPACES PARKING SPACES PROVIDED: NO CHANGES 125 EXISTING PARKING SPACES (NO CHANGE) AREA OF WORK TENANT AREALI =- INTERLINE EX DEMISING WALL TT' ® T V EXISTING TENANT SPACE NO WORK 11— - -R- — —rl-- -R- — —I1— — -H- 11---4F--U---H---U---1} AIII!l lIlir — —n— — -H- — —rl-- — -H- — —n- - -11-- +H---iI---H---il— INSTALL NEW EXTERIOR CONCRETE RAMP WITH SIDE WALLS IN FRONT OF EXISTING OVERHEAD DOOR. SEFE 4TE PERMITS: NOT REQUIRED OWNER CALWAEST kIDUSTRIAL HOLDINGS LLC C/O KIDDER MATHEWS 631 STRANDER BLVD., SUITE G TIKLIILA, WA 98188 PH: 253-893-1156 FX: 206-515-0121 V 0 - -H- - -il- -- -A- — —H — — A- — — --1J--1---11--— SITE PLAN SCALE: w = 30 FILE COPY Permit No. V I t O 46 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fie i t opy and coniitions is acknowledged: Date: luaNu City of Tukwila BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR: lid Mechanical El Electrical Plumbing al Gas Piping City of Tukwila BUZi,`y,^:,; , DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: n submittal may Revisions includell additional require add ional plan rev ew fees. andY S OT5TO5' W 797.00' V V EXISTING TENANT SPACE N0 WORK ❑I=I±=❑ ❑f❑I❑ ❑Z=I =❑ CIS=❑I❑ ELI= ❑I=I L❑ CIS=❑ID r--I---I--T- -�--i— i--r---i---1-- L_L-1—�—J--I—IL_ L—L—_L 1 VN l NO CHANGES TO BUILDING ENVELOPE NO CHANGES TO EXISTING LIGHTING. VICINITY MAP SCALE: N.T.S. BLDG E BLDG D Q a BLDG C % //B// LPG 6 BUILDING A ANDOVER PARK WEST 6) KEY SITE PLAN BCALE�NLB. SCALE: N.T.S. EXISTING TENANT SPACE NO WORK == SEP".26 2015 • REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 32015 Cit of Tukwila BUILDING DIVISION EXISTING TENANT SPACE NO WORK Star I 1l ber m Cry g Q E RECEIVED CITY OF TUKWILA DEC 3 0 2014 PERMIT CENTER piLVO3c S 0225 GVA 0 9 N DESCRIPTION 3 111 w 3 0 }- CO tb UJ 0- 0 g- CD m CNI N O) 0000 t�0 am- N co CO 00. w 0x. 0_� 0 co o _ ,r- rr Q? Z Ooo CO r-Q N—Mrn 0 C4 W z a a z 11 A PROPOSED TENANT IMPROVEMENT FOR ST BUSINESS SOUTHCENTER =1 EXISTING OFFICES NO CHANGES a . Jo J 0 ■ . EXISTING PAWING NO CHANGES EXISTING RESTROOMS NO CHANGES 1M INTERLINE 14W-0` ■ . ■ . ■ • NEW CONCRETE RAMP AREA OF WORT( GEE BLOW tP T-2 EX OFFICES NO CHANGE EX. WAREHOUSE ■ ■ DOCK HIGH DOCK HIGH EXISTING SHEAR WALL TO REMAIN 1111 C1-1AMP4 NO CHANGES . ��� _.- .Q-- II I) II II II I'I II A II II II a II II DOCK HIGH DOCK HIGH ic I X I • CONSTRUCT NEW DEMISING WALL LA EX. WAREHOUSE . 1169 EX. KOTIS NO C114NC ES . EXISTING ELECTRICAL EX. OFFICES NO CHANGE ■ EX. WAREHOUSE . R. Ix' LA 1161 EX. KOTIS NO CHANGES ■ . DOCK HIGH DRIVE 1 S 01°51'03" W 797.00' OCK HIGH DRIVE IN v ■ EXISTING SHEAR WALL TO REMAIN ■ X7LA • • DOCK HIGH V V EX. WAREHOUSE 1165 EXISTING KOTIS NO CI-1ANGE5 ■ . . LA IXI ILA oC 70 AGO' -^A---U------11---— II II II II II 1169 100 LP CCt1104 PATH OF TRAVEL t0 EXIT PA1HIU4Y 13 II II II II II 116-1 _1Ek_--_1_. `-�=a=_____ rII I I I I I I II II I I I I I II _______1:p===1====i=======tr_—=___ t#=====- 01165 21 OVERALL FLOOR PLAN: INTERLINE DEMO NORTH SCALE: inW:r-o. GoR-gva- JAB232r' city TulcwIla of BUILDING DIVISION .S '`.26 2005 I LI-- 0,3 9'5 -w* RECEIVED CITY OF TUKWILA DEC 3 0 2014 PEERIVET CENTER 0225 GVA DESCRIPTION r`O) rnIn 00 00 14-3 am- N (0 (0 00 w zc 0L A PROPOSED TENANT IMPROVEMENT FOR: INTERLINE RAMP S o UTHC ENTER W xw 0 'N w2 0 0_' ctm —‹ Q, Z or mJ F-00 (oQ mw '-tern C:1Documents and Settings\AII Users\Dacuments\CAD1200210225 GVA-KM\Southcenter West Business Park11177 INTERLINE 12-02-141RAMPISD-1 T-1 ADD EXIT.rrwn T.1 19/ J9n1e.11.)7.10 ARA 0 NI 49'-5" EX. OFFICE EX. OFFICE -J EX. OPEN OFFICE 0 ■ EX. OFFICE ■ EXISTING OFFICE TO REMAIN 1$19 5F4i1/100• 19 OCC. SINGLE EXIT O 0 EX. RESTROOMS AREA CF WORK MEW C4 Ratio III UP • ■ EXISTING WAREHOUSE MD MANUFACTURING 11,36-1 SPARER OFFICE DEMO 0I/500= 35 OCC. TWO EXIT DUE TO TRAVEL DISTANCES ■ ■ NORTH EXISTING MAN DOOR WITH STAIRS ADJACENT EXISTING ASPHALT OVERALL FLOOR PLAN: INTERLINE RAMP PLAN NO CHANGES TO MEMOIR WACO EXISTING OVERHEAD DOOR WITH STEEL TUBE MULLION NEW CONCRETE RAMP WITH SIDE WALLS DOOR SC1-4EULE: EXISTING NO CHANGES El EX. 3'4' STOREFRONT ENTRY DOOR, PADDLE EXIT E23 EX. 3'XT N. MIL DOOR AND JAMB, LOCKSET (ISNIDE I-IANPLE TURNS FREELY TO EXIT) E2-6 EX. 8'XI0' DOCK 14ICN DOORS E1-13, EX. 3'X1' 5C WOOD DOOR AND UJOOD JAMB, LOCKSET OR LATCNSET 11 E14,15 EX. 3'X1' SC WOOD DOOR AND WOOD JAMB, PRIVACY LOCK E1, EX. PAIR 3'4V SC WOOD DOOR AND WOOD JAMB, LATCI-!SETS E18-21 EX. 3'4' SC WOOD DOORS AND UJOOD JAMB, TO BE REMOVED CONCRETE VERTICAL WALL REINFORCED, PAINTED, SACK AND FILL VOIDS, CHAMFER TOP 6" CONCRETE SLAB REINFORCED WITH 04'S AT 12" O.C. E.W. DOWEL TO SIDE WALL COMPACTED STRUCTURAL FILL MIN. 95% COMPACTION (ALTERNATE STRUCTURAL FOAM) PUNCH HOLDS OIR BREAK UP EXISTING ASPHALT UNDER RAMP WALL HEIGHT ABOVE RAMP IS 42" UNTIL GROUND LEVEL AND RAMP GET TO 30" THEN WALL TO GO TO If ABOVE, RAMP PROVIDE MEP HOLES AT 4' O.C. AT BASE OF CONCRETE WALLS PATCH BACK ASPHALT TO EXISTING ASPHALT AND TO WALL. PROVIDE LIQUID ASPHALT AT PATCH LINE NEW CCNCRE PE RAMP 6" SLAB WITH 4'8 AT 12" O.C. E.W WITH CONCRETE SIDES 10"-0" NORT1-4 INTERLINE RAMP BLOW UP PLAN SCALE: 1/8":1'-0' EXISTING TILT UP CONCRETE WALL WITH EXISTING OVERHEAD DOORS EXISTING OVERHEAD DOORS NEW CONCRETE RAMP WITH CONCRETE SIDE WALLS (42" ABOVE RAMP AT 30" OR ABOVE GRADE CHANGE, 12" ABOVE RAMP A1130" AT BELOW CONCRETE RAMP SURFACE - EXISTING ASPHALT PATCH AT NEW RAMP AND WALLS PUNCH THE EXISTING ASPHALT UNDER THE NEW RAMP, AND THEN IN FILL BENEATH THE RAMP WITH COMPACTED STRUCTURAL FILL OR RIGID FOAM STRRCTURAL BLOCKS .SER26 2i5 01/4.5 9 s REVIE\NED FOR CODE COMPLIANCE. JAB 2 3 2015 City of Tul( ►i1a BUILDING••ar DIVISION NECE VED CITY OF TUKWILA DEC 3 0 2014 0226 GVA W a w i I N w Q m LU DESCRIPTION } N 0) PO 03 00 N 00 N N w OX C A PROPOSED TENANT IMPROVEMENT FOR: INTERLINE S O UTHC E NTE R FRONT ELEVATION OF RAMP SCALE: 1/1",1'0" SECTION OF RAMP SCALE: 3/4°=11_0"� SIDE ELEVATION OF RAMP SCALE: I/4":I'-0" C:\Documents and Settinds\ARI Users\Documents\CAD12norAn225 (VA-KM1Snilthr antur Mutt N''ERcvni CENTER Rutinnee DsrI, ll77IAITCDI IAIC 49 An 4A CIAI1rten 4 T A A11,1 FVI•F 1 1000 GENERAL 3000 CONCRETE 1001 GENERAL REQUIREMENTS THE STRUCTURAL NOTES SUPPLEMENT THE PLANS AND SPECIFICATIONS. ANY 3001 REINFORCING STEEL REINFORCING STEEL DETAILING, FABRICATION, AND PLACEMENT SHALL BE PER ACI 318- 10'-0" THE DRAWINGS, NOTES, SPECIFICATIONS, SITE STEEL SHALL MEET THE FOLLOWING REQUIREMENTS: J' J' DISCREPANCY FOUND BETWEEN CONDITIONS, AND ARCHITECTURAL PLANS SHALL BE REPORTED TO THE ARCHITECT WHO SHALL CORRECT THE DISCREPANCY IN WRITING. ANY WORK COMPLETED AFTER DISCOVERY OF THE DISCREPANCY SHALL BE DONE AT THE CONTRACTOR'S RISK. REFER TO ARCHITECTURAL PLANS FOR OPENINGS, ARCHITECTURAL TREATMENTS, AND DIMENSIONS NOT SHOWN. CONSULT MECHANICAL PLANS FOR DUCTS, PIPES, ETC. NOT 11. REINFORCING ASTM A-615 DEFORMED BARS GRADE 40 (fy=40 KSI) FOR #3 BARS ONLY ASTM A-615 DEFORMED BARS GRADE 60 (fy=60 KSI) FOR #4 BARS AND LARGER ASTM A-706 DEFORMED BARS GRADE 60 (fy=60 KSI) FOR ALL WELDABLE BARS ASTM A-185 SMOOTH BAR (fy=60 KSI) FOR WELDED WIRE FABRIC. a 4 S1.0 —� allO►' 1 S1.0 �, SHOWN. THE CONTRACTOR SHALL PROVIDE BRACING AND SUPPORT REQUIRED FOR TEMPORARY CONSTRUCTION LOADS AND FOR STRUCTURAL COMPONENTS AS REQUIRED DURING ERECTION. ' BACKFILL BEHIND WALLS SHALL NOT BE PLACED UNTIL THE WALLS ARE PROPERLY SUPPORTED. REINFORCING FOR SLABS ON GRADE SHALL BE 6X6 W 1.4XW I.4 WELDED WIRE FABRIC UNLESS NOTED OTHERWISE. PROVIDE LAP SPLICES MINIMUM 36 BAR DIAME I'ERS. REINFORCING STEEL AT ALL WALLS, SLABS, AND FOOTINGS SHALL BE CONTINUOUS AROUND CORNERS ELSE CORNER BARS SHALL BE PROVIDED. NOTED I— — f — — —I �- 6" CONCRETE WALL ,�►, THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL WORK COVER REQUIREMENTS SHALL BE AS FOLLOWS UNLESS OTHERWISE: (F1.10) S.J. (F1.10) INCLUDING BUT NOT LIMITED TO EXCAVATION, SHORING, AND OTHER WORK WITH ALL UTILITIES AND ADJACENT PROPERTIES. CALL THE UTILITY LOCATE SERVICE PRIOR TO CONCRETE CAST AGAINST EARTH ALL BAR SIZES 3" FORMED SURFACE EXPOSED TO EARTH OR WEATHER 2-#4 CONT. BOT. 3 S1.0 NEW RAMP 6" CONCRETE SLAB ANY WORK AT 1-800-424-5555. #5 AND SMALLER 1 1/2" 2" CHAMFER 6" CONCRETE SLAB b, L L J W/#4 0 12"OC EACH WAY 1002 CODE REQUIREMENTS RE PLAN FOR M r ALL DESIGN AND CONSTRUCTION SHALL CONFORM TO THE 2012 INTERNATIONAL REINFORCING STEEL SHALL BE ACCURATELY PLACED AND ADEQUATELY SECURED IN PLACE PRIOR TO CONCRETE PLACEMENT. REINFORCING STEEL SHALL NOT BE FIELD BENT EXCEPT AS NOTED IN THE DESIGN DRAWINGS: WELDING OF REINFORCING STEEL ASPHALT RE ARCH REINFORCING S J 1 (E) STEEL STAIRS BUILDING CODE AS ADOPTED BY THE LOCAL JURISDICTION. SHALL NOT BE PERMITTED WITHOUT PRIOR APPROVAL OF THE ENGINEER OF RECORD EXCEPT ON THE DESIGN DRAWINGS. r..............::_ _ - - - a AS NOTED M ... of (F2.9) �F2.9� r- 1003 DESIGN LIVE LOADS / DATA #4 0 18 O.C. 3100 CAST -IN -PLACE CONCRETE 2'-0" LIVE LOADS FLOOR RAMP SLAB 250 PSF CONCRETE CONSTRUCTION SHALL CONFORM TO THE AMERICAN CONCRETE INSTITUTE STANDARD ACI 318-11 `BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE". 1 -0 - - WIND DESIGN DATA BASIC WIND SPEED 110MPH (3 SECOND GUST) WIND IMPORTANCE FACTOR Iw = 1.0 WIND EXPOSURE EXPOSURE B TOPOGRAPHIC FACTOR Kt = 1.00 CEMENT AND CONCRETE SHALL CONFORM TO IBC SECTION 1903. ADMIXTURES SHALL BE APPROVED BY THE ENGINEER OF RECORD AND SHALL COMPLY WITH ACI 318-11 SECTION 3.6. CONCRETE EXPOSED TO FREEZING AND THAWING SHALL HAVE AN AIR ENTRAINING ADMIXTURE CONFORMING TO IBC SECTION 1904.2. THE USE OF WATER SOLUBLE CHLORIDE ION SHALL NOT BE USED. SCALE 3/4" =1'-0" (E) BUILDING 2 51.0 �- COMPONENT &SSURE CLADDING COEFFICIENT P(c)1= 25 P SF8 THE CONTRACTOR SHALL SUBMIT MIX DESIGNS TO ENGINEER OF RECORD FOR 1 T 1�/ fD CAL I C A L EXTERIOR ' (; SLAB EDGE WIND PRESSURE APPROVAL FOUR WEEKS PRIOR TO PLACING CONCRETE. MIX DESIGNS SHALL BE EARTHQUAKE DESIGN DATA SEISMIC IMPORTANCE FACTOR Ie = 1.0 OCCUPANCY CATEGORY II SPECTRAL RESPONSE ACCELERATIONS Ss = 1.49; S1 = 0.536 SITE CLASS SITE CLASS D REVIEWED FOR CONFORMANCE TO IBC SECTIONS 1904 AND 1905. CONCRETE MIX DESIGNS SHALL MEET THE FOLLOWING REQUIREMENTS: (1) 28 DAY STRENGTH fc [PSI] (2) MAX. WATER / CEMENT RATIO (3) MAX. SLUMP [IN] (4) AIR ENTRAINMENT SPECIAL INSPECTION REQUIRED MIN. 90 LB SACKS OF Ramp Foundation Plan SD1 = 0.536 [%] (5) (6) (2) #4 CONT. 1 ISSI L>' SPECTRAL RESPONSE COEFFICIENTS SDS = 0.959; SEISMIC DESIGN CATEGORY D 1004 GEOTECHNICAL INVESTIGATION CEMENT (7) LOCATION AND APPLICATION. (1) (2) (3) (4) (5) (6) (7) 3000 0.50 5 +/- 1 0 +/-1 YES 5 ALL CONCRETE ONE COMPRESSION TEST MINIMUM SHALL BE COMPLETED FOR EVERY 150 CUBIC YARDS #4x1 SET W/EPDXY 5" SLAB ...\\_— -8�� DOWEL 0 18,� OC N I E O CONCRETE WALL f (E) CONCRETE SLAB 7- SCALE: 1 /8" = 1'-O" REFER TO ARCHITECT FOR LOCATION OF RAMP. EARTHWORK AND FOUNDATIONS SHALL BE CONSISTENT WITH THE GEOTECHNICAL OR 5000 SQUARE FEET OF SURFACE AREA FOR EACH MIX DESIGN PLACED EACH DAY. A TEST SHALL BE THE AVERAGE STRENGTH OF TWO CYLINDERS MADE FROM THE SAME 8" L.-L L = = Foundation Schedule ENGINEERING RECOMMENDATIONS. ALL FOUNDATIONS SHALL BE FOUNDED ON SAMPLE AND TESTED AT THE SPECIFIED AGE. ADDITIONAL CYLINDERS MAY BE MADE \ i 1_:I 11:.. 1 COMPETENT NATIVE MATERIAL OR BY OTHER MEANS AS DEFINED B Y THE GEOTECHNICAL ENGINEER. FOR INFORMATION REGARDING POST TENSIONING, FORM REMOVAL STRENGTH DEVELOPMENT, OR OTHER PURPOSES. CONCRETE SHALL BE ACCEPTABLE IF: I MARK DEPTH WIDTH REINFORCING DETAILS 1. NO TEST FALLS 500 PSI BELOW THE SPECIFIED STRENGTH $ " (F1.10) CONT. ': 10" 1'-10" (2) #5 BOTTOM FOUNDATIONS SHALL BE SUPPORTED ON SPREAD FOOTINGS. ASSUMED ALLOWABLE 2. THE AVERAGE OF ALL SETS OF 3 CONSECUTIVE TESTS DOES NOT FALL BELOW BEARING CAPACITY IS 2,000 PSF. THE SPECIFIED STRENGTH. NOT THE ABOVE CRITERIA SHALL BE SUBJECT TO FURTHER COMPACTED STRUCTURAL FILL 4" _..._... (F2.9) 10" 2'-9" (3) #5 CONT. BOTTOM CONCRETE MEETING MIN. 95% COMPACTION I DESIGN PARAMETERS ARE AS FOLLOWS: ACTIVE EARTH PRESSURE (YIELDING) 35 PCF TESTING ATNO ADDITIONAL EXPENSE TO THE OWNER. (ALTERNATE STRUCTURAL FOAM) PASSIVE EARTH PRESSURE 150 PCF (ALLOWABLE) CHAMFER ALL EXPOSED CORNERS PER THE ARCHITECTURAL PLANS OR % INCH IF NOT COEFFICIENT OF FRICTION 0.35 (ALLOWABLE) SOIL PROFILE SITE CLASS D SPECIFIED BY THE ARCHITECT. I 1005 REQUIRED SUBMITTAL PROCEDURES THE CONTRACTOR SHALL PROVIDE THE FOLLOWING SUBMITTALS TO THE ENGINEER OF 8000 POST INSTALLED ANCHORS — SIMPSON STRONG —TIE , I......... ; ; _ I : ,..._.. - RECORD FOR APPROVAL FOUR WEEKS PRIOR TO POUR OF CONCRETE OR FABRICATION. SHOP DRAWINGS SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT AND 8100 EPDXY ADHESIVE ANCHORS CONCRETE ENGINEER OF RECORD FOR APPROVAL PRIOR TO FABRICATION. IF SHOP EPDXY SPECIFIED IN THE DRAWINGS SHALL BE SIMPSON STRONG -TIE SET-XP EPDXY SCALE: 3/4" = t'-0" DRAWINGS DIFFER FROM THE APPROVED DESIGN DRAWINGS, NEW DESIGN DRAWINGS BEARING THE SEAL AND SIGNATURE OF A LICENSED ADHESIVE. ANCHOR ROD, THREADED ROD, OR REINFORCING DIAME 1'ER AND EMBEDMENT PER PLAN. AS A MINIMUM PERIODIC SPECIAL INSPECTION IS REQUIRED PER SECTION WASHINGTON STATE STRUCTURAL ENGINEER SHALL BE SUBMITTED SECTION 4.4 OF ESR-2508. ALONG WITH THE SHOP DRAWINGS TO THE APPROPRIATE JURISDICTION FOR APPROVAL PRIOR TO FABRICATION. SHOP DRAWINGS ARE REQUIRED FOR: CONCRETE REINFORCEMENT CONCRETE MIX DESIGN RE: SECTION 3100 REFER ARCH. R REMEO PL"CE ,0 Q 1006 CODE REQUIRED SPECIAL INSPECTIONS FOR TOP ;OF WALL ELEVATION �� 6" CONCRETE VERTICAL APPR°� JAA 3 2$315 THE CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE ALL INSPECTIONS REQUIRED BY THE LOCAL BUILDING DEPARTMENT. IN ADDITION TO INSPECTIONS REQUIRED BY THE LOCAL BUILDING DEPARTMENT, THE OWNER OR A REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE ACTING AS THE OWNER'S AGENT SHALL EMPLOY ONE OR MORE SPECIAL INSPECTORS TO PROVIDE INSPECTIONS FOR ITEMS NOTED IN IBC SECTION 1705. in TOP OF WALL • WALL REINFORCED, PAINTED, SACK AND FILL VOIDS, CHAMFER TOP 0{ i�%�Ii 1 ���� ITEMS REQUIRED; SOILS CONCRETE 0 SIM. \ - �i xit,/ ` ) EPDXY DOWELS 4' #4x2'-6" DOWEL 12"OC E TILT -UP ( ) SET W/EPDXY S 2615 CONCRETE WALL THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON EMPLOYED BY AN APPROVED AGENCY. THE SPECIAL INSPECTOR SHALL KEEP RECORDS OF INSPECTIONS AND FURNISH - - _- \ - _ =-_ = = �-_ \ _ • - (2) #4 CONT. .SEP, 2 THEM TO THE BUILDING OFFICIAL AND THE ENGINEER OF RECORD ON A REGULAR BASIS. 12"OC HORIZ. A FINAL REPORT DOCUMENTING REQUIRED SPECIAL INSPECTIONS AND THE CORRECTION OF ANY DISCREPANCIES SHALL BE PROVIDED PRIOR TO COMPLETION OF BUILDING #4 0 0 18"OC VERT. FINISHES. WHERE FABRICATION OF STRUCTURAL COMPONENTS AND ASSEMBLES IS BEING PERFORMED ON THE PREMISES OF A FABRICATOR'S SHOP, SPECIAL INSPECTION OF #5 -,.... " 1.«... "..'"'"'""i'"e" ' �� 19 -0 (E) OVERHEAD � DOORS THE FABRICATED ITEMS SHALL BE REQUIRED EXCEPT HERE THE FABRICATOR IS STRUCTURAL FILL " / 11 -0 REGISTERED AND APPROVED TO DO SUCH WORK WITHOUT SPECIAL INSPECTION IN ACCORDANCE WITH IBC SECTION 1704.2.2. PERIODIC INSPECTION ALLOWS INSPECTION AT INTERVALS NECESSARY TO CONFIRM THAT WORK REQUIRING SPECIAL INSPECTION IS COMPACTED MIN. 95% COMPACTION (ALTERNATE STRUCTURAL FOAM) PROVIDE WEEP HOLES 0 48 OC AT BASE OF CONCRETE WALL NEW / IN COMPLIANCE WITH REQUIREMENTS. CONTINUOUS SPECIAL INSPECTION REQUIRES PATCH BACK ASPHALT TO CONCRETE RAMP THAT THE INSPECTOR BE ONSITE AT ALL TIlVIES THAT WORK REQUIRING SPECIAL INSPECTION IS PERFORMED. PUNCH HOLES OR BREAK UP EXISTING ASPHALT UNDER RAMP _i_ EXISTING ASPHALT PROVIDE UQUID PATCH LINE. AND TO WALL. ASPHALT AT W/CONCRETE SIDE WALLS (42" ABOVE RAMP AT 30" OR ABOVE GRADE CHANGE, 12" ABOVE RAMP AT 30" AT BELOW). • -" -c-- r- - r 1 - - - -I I- I ( r —I 4 ; ASPHALT PATCH j-I- I-- . ,, 1 —0 " (E) AT NEW RAMP AND WALLS 6" CONCRETE RAMP _ BEYOND - - - - -I-_-I--_i_ , J - '� --� - "I #4x2 -6 DOWEL 10" \ t;-0; E — 1 1I I _ I I I I L L TO WALL BELOW =-- • ,' , \ - —1= —�--�-_ — —1 — — — _. —I _ �_�--� — ..L. - 1 �� T 1' T T I I r r 1 1-0�_ 1 ( I 1 I I �-==+— —--r--I-- —--I---I- — — ——t--�-- —t— SLAB ONLY - -4 -a -I -( -I -4 .__l -4 4- 4- 4- REINFORCING10" �� RE: SCHEDULE � RE SCHEDULE 6" 8" / RE: SCHEDULE / (E) FTG IVED/ PUNCH THE EXISTING ASPHALT UNDER THE NEW RAMP, RECEIVED SCALE: 3/4" = 1'-0" / AND THEN IN FILL BENEATH THE RAMP W/COMPACTED STRUCTURAL FILL OR RIGID FOAM STRUCTURAL BLOCKS. b SCALE 1/4" = 1'-0" CITY E?F li 4 .J 1.4 DEC 3 0 201 3 SECTION 4 SECTIONPERMIT CENTER 4 12/29/14 FILE: 14342S10 't PERMIT SUBMITTAL 4 ti O cp PLOT: 12/29/14 CAD: JMA ENGR: CJM z