Loading...
HomeMy WebLinkAboutPermit EL14-0034 - BOEING #9-120 - TENANT IMPROVEMENTBOEING #9-120 9725 EAST MARGINAL WY S ELi 4-0034 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 0003400018 9725 E MARGINAL 120 BOEING #9-120 ELECTRICAL PERMIT Permit Number: EL14-0034 WAY S BLDG 9- Issue Date: 2/3/2014 Permit Expires On: 8/2/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: BOEING COMPANY THE PO BOX 3707 M/C 20-00 PROPERTY TAX DEPT, SEATTLE, WA, 98124 BRIAN NEARY 2400 NW 80 ST, SUITE 118, SEATTLE, WA, 98117 Phone: (206) 937-6150 FOY INDUSTRIAL ELECTRIC CORP Phone: (206) 937-6150 Address: 2400 NW 80 ST STE 118 , SEATTLE, WA, 98117 License No: FOYINEC015CH Expiration Date: 2/7/2015 Lender: Name: Address: DESCRIPTION OF WORK: TENANT IMPROVEMENT REMODEL OF THE SECOND FLOOR SPACE. (2) NEW ELECTRICAL ROOMS, A MAIN ELECTRICAL ROOM AND A SATELLITE ELECTRICAL ROOM AND EQUIPMENT. NEW OFFICES THROUGHOUT AND A RAISED FLOOR SYSTEM ON THE SOUTH END OF THE SPACE. A NEW DATA CLOSET ON THE EAST END OF THE SPACE WITH OVERHEAD CABLE TRAY GOING THROUGHOUT THE SPACE Valuation of single family: $0.00 Valuation of mf/comm: $685,000.00 Type of Work: TENANT IMP Fees Collected: $9,811.68 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer Distric: TUKWILA SEWER SERVICE,VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Si gnature: la Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: V w,'116.— ' Hia +e �. Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Electrical Permit No. 1-�-1`- QQ 3 I Project No. Date Application Accepted: Date Application Expires: (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: Tenant Name: 9725 E. Marginal Way South The Boeing Compnay King Co Assessor's Tax No.: Suite Number:Bldg 9-120 Floor: PROPERTY OWNER Name: The Boeing Compnay Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: Brian Neary Address: 2400 NW 80th Street #118 City: Seattle State: WA Zip: 98117 Phone: (206) 937-6150 Fax: (206) 935-1163 Email: brian.n@foygroup.net 2nd New Tenant: ❑ Yes ❑✓ ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: Foy Group Address: 2400 NW 80th Street #118 City: Seattle State: WA Zip: 98117 Phone: (206) 937-6150 Fax: (206) 935-1163 Contr Reg No.: FOYINECOI5CH Exp Date: 02/07/2014 Tukwila Business License No.: 0100585 Valuation of Project (contractor's bid price): $ 685,000 Scope of Work (please provide detailed information): TI remodel of the 2nd floor space. 2 new electrical rooms, a main electrical room and a satellite electrical room and equipment. New offices throughout and a raised floor system on the south end of the space. A new data closet on the east end of the space with overhead cable tray going throughout the space. Will service be altered? j,g1 Yes ❑ No Adding more than 50 amps? A Yes ❑ No Type of Use: Industrial Type of work: ❑ New ❑ Service Change ❑ Remodel ❑✓ Tenant Improvement ❑ Low Voltage ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service ❑ Addition ❑ Generator Property Served by: ❑ Puget Sound Energy 7‘1\ Seattle City Light IIAApplications\Forms-Applications On Line \2011 Applications \Elecoical Permit Application Revised 1.9-I l.docx Revised: August 2011 bit Page I of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 O Manufactured/mobile home service $84.00 (excluding garage or outbuilding) O Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND T AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: Brian Ne Mailing Address: 2400 NW 80th Street #118 i 1:\Applications\Forms-Applications On Linc'20I I Applications\Electrical Pcmmit Application Revised 8-9-I1.docx Revised: August 201 1 bh Date: 01/14/2014 Day Telephone: (206) 937-6150 Seattle WA 98117 City State Zip Page 2 of 2 DESCRIPTIONS PermitTRAK Cash Register Receipt City of Tukwila ACCOUNT QUANTITY I PAID $8,911.68 E1.14-0034 Address:.9725 E MARGINAL WAY S BLDG 9-120 Apn: 0003400018 $8,911.68 ELECTRICAL $8,534.31 PLAN CHECK FEE R000.345.832.00.00 $986.86 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 $7,547.45 TECHNOLOGY FEE $377.37 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R793 R000.322.900.04.00 $377.37 $8,911.68 Date Paid: Thursday, January 16, 2014 Paid By: FOY GROUP Pay Method: CHECK 93128 Printed: Thursday, January 16, 2014 3:10 PM 1 of 1 RSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $292.50 EL14-0034 Address: 9725 E MARGINAL WAY S BLDG 9-120 Apn: 0003400018 $292.50 DEVELOPMENT $292.50 PERMIT REINSPECTION FEE TOTAL FEES PAID BY RECEIPT: R1101 R000.322.800.00.00 $292.50 $292.50 Date Paid: Thursday, February 06, 2014 Paid By: JERRY HJORTEN Pay Method: CREDIT CARD 316085 Printed: Thursday, February 06, 2014 11:59 AM 1 of 1 CRWSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT I QUANTITY PAID $900.00 EL14-0034 Address: 9725 E MARGINAL WAY S BLDG 9-120 Apn 0003400018 $900.00 ELECTRICAL $900.00 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R749 R000.345.832.00.00 $900.00 $900.00 Date Paid: Tuesday, January 14, 2014 Paid By: JERRY HJORTEN FOY INDUSTRIAL E Pay Method: CREDIT CARD 714174 Printed: Tuesday, January 14, 2014 3:47 PM 1 of 1 SYSTEMS (l INSPECTION RECORD AILI, 003 Retain a copy with permit `� INSPECTION NO. PERMIT NO. I CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: s351 �� ! io "fil 0- Type of Inspection:flitiAN Address: ?72C' �l/ ./ Date Called: -tea Special Instructions: E Date Wanted: 7io/ a.m p.m. Requester: r. Phone No: Approved per applicable codes. s COMMENTS: Corrections required prior to approval. C ,041(-'45 fl ,* (ri Inspector: Date: 001 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. /11,0edfski, /0 INSPECTION NO. INSPECTION -RECORD Retain a copy with permit 64- oo3,1 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Type of Inspection: ,�- Address: n7t- ( , n , Date Called: Date Wanted:61A- a.m m. Special Instructions: Requester: Phone No: JApproved per applicable codes. Corrections required prior to approval. COMMENTS: ticaJvL) 6.12. t,JOr1C J`' �Gr c,J0 i wolk.4.tn)t,, Date: oe fich, • REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: J INSPECTION RECORD kii1-00311 Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: i Det�� 1 1-( Type of Inspection: fr.) dV f, L - ra`VI Address: / 72 5,--(. ,i% . Date Called: Special Instructions: i Date Wanted: 6/05 p.m. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: QA, A / `f . �- /Ivy fj. eta -a“ ` txtl°T e,)4Feik.Nc,6, R0o15 Jr1 f PLt f6c,TT25 A4P Zt Gy R, s A-uDtiiolki- cpi' )IT 5Oo&t/77 J L C<A tJ r del 3/y i'' t-fhi-r iJt1 - A 1569 (coc Inspector: Date: 04/0 J4 t I REINSPECTION FEE REQUIRED. Prior to next inspection,- fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION"'RECORD Retain a copy with permit PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila; WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: �j- 7 / Type of Inspection: set, C Address?' rfAt_ Date Called: Special Instructions: Date Wanted: �/ Z� Cam p; .m. Requester: Phone No: ❑ Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: f - . ` CAtaltt7 A-t1ie5- W'6 a1,( C;, tA(2- o 4 b(siaJpiecli tAtlik U rJ ;1 r f r ckkw t r. tNcelEi., - PA)bc-c-.0,riM- t30,11)11t1 SJr�rrrt'o Inspector: i pibriv," Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSP CTION NO. PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: jam' of l �1ZQ Type of Inspecti 1115152Air Address: l/ g-t. Date Called: Special Instructions: Date Wanted: i./ 4a•r p.m. Requester: Phone No: DApproved per applicable codes. L�J Corrections required prior to approval. COMMENTS: c)f/ Musdli vim, LAffir syk Dr-Cfr,(44b So Jn+ A I.fkcr 4 C3 f ` t. Inspector: e. -**71,4 Date: 60/71)11/ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD r, Retain a copy with permit o cy INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: t / ARN it-7 (2,0 Type of Inspection: r otA4 ti IA/ Address: imttDate rms Called: Special Instructions: Date Wanted: I f,7 Requester: ri Phone No: 0 f? t Approved per applicable codes. Corrections required prior to approval. COMMENTS: kbr egiNi Inspector: frib ) r tec Date: r- REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit kei-093if PERMIT NO. I CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Permit Inspection Request Line (206) 431-2451 (206) 431-3670 Project: r-/� �� 1— 1 } Type of Inspection: `f,, . l �r Address: 7(vC� 11+. Date Called: Special Instructions: Date Wanted: / C7 a.m p.m - Requester: Phone No: ElApproved per applicable codes. El Corrections required prior to approval. COMMENTS: Ai\ - ?/)46A A-4.D yffrik.S ()fair 441) /4.-i--',„-pA416, Inspector: Date: di:111)41K\ �t(/oL REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit (titt —003 PERMIT NO. ' CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Nil 4- 7 Type of Inspection: AO l4 Address: ipie(Ittosi4Date Called: Special Instructions: Date Wanted: ,( 2l a.m p.m. Requester: ` Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: s50 ir5 AirZ Se 14kitsDND(Cco�D� Loggr Inspector: \711-664/J0\ Date: 02- Pit/ REINSPECTI©N FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION' RECORD Retain a copy with permit INSPECTION NO. Euq-Oo3y PERMIT NO. I CITY OF TUKWILA► BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project:k6/J41 ! Type of Inspection: Address: ?7Ae-6* ititivei Date Called: Special Instructions: Date Wanted: �8 a.m p.m. Requester: t Phone No: DApproved per applicable codes. Corrections required prior to approval. COMMENTS: - inA, ulwo Date: Qz r REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Retain a copy with permit 1 O0 INSPECTION NO. PERMIT N . Project / j (�_��� !7 Type of Inspection: . `s r Val + a Address: 41 Date Called: Special Ins ructions: ! Date Wanted: 2 /t� /( a.m: Requester: Phone No: Approved per applicable codes. D Corrections required prior to approval. COMMENTS: 1 YA-/ ci — t-JA14 tos/e-K, A- L_ide u4c pki-urgivil 61,1 Prt* ©1. t-rig5 / 5- Al ciu,40.3c)tku!_ ifTt( f j tom Inspector: Date: t i REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. t14-od31 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 INSPECTIONERECORD Retain a copy with permit Project: It t / 20 geetdc. Type of Inspection: %!"n i i 'J CC - Address: q7—Date Called: Special Instructions: Date Wanted: a ,* Requester:�� Phone No: 6 xi7 Y LiZ-- Approved per applicable codes. Corrections required prior to approval. COMMENTS: ?"( fry rels4(c3 ZFL- -kri tAT 01,15 t,fQad 46r4 ( % 3r Jprn/ EFcr" d[ Z (Slid � .� chi- . c, A, Date: 4d osit t t REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 1:131N3311W83d LOAD SUMMARY SUBSTATION 35 SUBSTATION No. 35 (480V-3PH-4W-1600A) MAX SINGLE DAY LOAD READING (NOTE 1) 199.20 kVA x 1.25 NEC DEMAND FACTOR = 249 kVA 249.00 kVA x 1.00 SEASONAL CORRECTION FACTOR = 249 kVA TOTAL NEC DEMAND LOAD NEW LOAD ADDED PANEL 2A7-1 600A BUS DUCT (NOTE 2) TOTAL LOAD ON SUBSTATION 35 (NEC DEMAND LOAD + NEW LOAD) 249.00 kVA 125.21 Kva 498.00 Kva 872.21 kVA 1049.13 AMPS AT 480V NOTES: 1. BUILDING LOAD CONSTANT DUE TO USAGE TYPE. LONGER DURATION LOAD READING WILL BE PROVIDED PRIOR TO PERMIT. 2. BUSDUCT LOAD COUNTED AT NAME PLATE RATING OF 600A. co c _ i Zp z yrrn L, -" C&: U c ►--' o Z m = 74 2 4 ELECTRICAL PANEL SCHEDULE SUB 35 Panel Designation 2A7-1 Panel Type Main Bkr Rating '800A Panel Rating 800A, 480V, 3 PH, 3W 35KAIC Ref. Dwg.No. 09-120-E4S35 Revision Engineer CEI/B.MAXWELL Location, bldg. 9-120.2 col. A/7 Date Installed Feeder Size (3)2-1/2" - 3#300kcmil & 1 #1/0G Fed From SUBSTATION NO. 35 - F2 Revised Ckt NEW PANEL Date Revised 12/05/13 Job Number 131174-00 Ckt 1a 3b 5c Breaker Type Frame Trip 100A 3P Wire Size #2 #2 #2 Load Served PANEL 2A7-2 Load Amps Ph A Ph B Ph C Location ELEC RM 21A6 ELEC RM 21A6 ELEC RM 21A6 7a 9b 11c 100A 3P #2 #2 #2 PANEL 2B2-2 VIA 75KVA TRANSF 67.1 63.5 ELEC RM 23A1 ELEC RM 23A1 ELEC RM 23A1 13a SPACE ONLY 15b SPACE ONLY 17c SPACE ONLY 19a 21b SPACE ONLY SPACE ONLY 23c SPACE ONLY 25a SPACE ONLY 27b SPACE ONLY 29c SPACE ONLY 31a SPACE ONLY 33b SPACE ONLY 35c SPACE ONLY 37a SPACE ONLY 39b SPACE ONLY 41c SPACE ONLY 2a 4b 6c 100A 100A 100A #2 #2 #2 PANEL 2A7-3 VIA 75KVA TRANSF 76.7 83.8 84.9 ELEC RM 21A6 ELEC RM 21A6 ELEC RM 21A6 8a SPACE ONLY 10b SPACE ONLY 12c SPACE ONLY 14a SPACE ONLY 16b SPACE ONLY 18c SPACE ONLY 20a SPACE ONLY 22b SPACE ONLY 24c SPACE ONLY 26a SPACE ONLY 28b SPACE ONLY 30c SPACE ONLY 32a SPACE ONLY 34b SPACE ONLY 36c SPACE ONLY 38a SPACE ONLY 40b SPACE ONLY 42c SPACE ONLY TOTAL 12/5/2013 2A7-1.XLS 149.9 150.9 148.4 ELECTRICAL PANEL SCHEDULE SUB 35 Panel Designation 2A7-2 Panel Type Main Bkr Rating 100A Panel Rating 225A, 480V, 3 PH, 3W 35KAIC Ref. Dwg.No. 09-120-E4S35 Revision Engineer CEI/B.MAXWELL Location, bldg. 9-120.2 col. A/7 Date Installed Feeder Size 1-1/4"-3#2 & 1#8G Fed From 2A7-1 Revised Ckt NEW PANEL Date Revised 12/5/2013 Job Number 131174-00 Ckt Breaker Type Frame Trip Wire Size Load Served Load Amps Ph A Ph B Ph C Location 1a 3b 5c 7a 9b 11c 20A 3P 20A 3P SPARE C.B. SPARE C.B. 13a SPACE ONLY 15b SPACE ONLY 17c SPACE ONLY 19a SPACE ONLY 21b SPACE ONLY 23c SPACE ONLY 25a SPACE ONLY 27b SPACE ONLY 29c SPACE ONLY 31a SPACE ONLY 33b SPACE ONLY 35c SPACE ONLY 37a SPACE ONLY 39b SPACE ONLY 41c SPACE ONLY 2a 4b 6c 20A 3P SPARE C.B. 8a 10b 12c 20A 3P SPARE C.B. 14a SPACE ONLY 16b SPACE ONLY 18c SPACE ONLY 20a SPACE ONLY 22b SPACE ONLY 24c SPACE ONLY 26a 28b 30c SPACE ONLY SPACE ONLY SPACE ONLY 32a SPACE ONLY 34b SPACE ONLY 36c SPACE ONLY 38a SPACE ONLY 40b SPACE ONLY 42c SPACE ONLY TOTAL 12/5/2013 2A7-2.XLS ELECTRICAL PANEL SCHEDULE SUB 35 Panel Designation 2A7-3 Location, bldg. 9-120.2 col. A 7 Panel Type Date Installed Main Bkr Rating 225A Feeder Size 2-1/2"-4#4/0 & 1#2G Panel Rating 225A, 208Y/120V, 3 PH, 4W Fed From 2A7-1 VIA 75KVA XFMR Ref. Dwg.No. Revision Engineer 10KAIC 09-120-E4S35 CEI/B.MAXWELL Revised Ckt NEW PANEL Date Revised 12/05/13 Job Number 131174-00 Ckt 1a 3b 5c Breaker Type Frame Trip 100A Wire Size #2 2A7-4 Load Served Load Amps Ph A Ph B 59.5 Ph C Location 75.0 72.0 7a 9b 11c 100A #2 2A7-5 62.5 60.0 61.0 13a SPACE ONLY 15b SPACE ONLY 17c SPACE ONLY 19a SPACE ONLY 21b SPACE ONLY 23c SPACE ONLY 25a SPACE ONLY 27b SPACE ONLY 29c SPACE ONLY 31a SPACE ONLY 33b SPACE ONLY 35c SPACE ONLY 37a SPACE ONLY 39b SPACE ONLY 41c SPACE ONLY 2a 4b 6c 100A #2 2A7-6 55.0 58.4 62.9 8a 10b 12c 100A SPARE C.B. 14a SPACE ONLY 16b SPACE ONLY 18c SPACE ONLY 20a SPACE ONLY 22b 24c SPACE ONLY SPACE ONLY 26a SPACE ONLY 28b SPACE ONLY 30c SPACE ONLY 32a SPACE ONLY 34b SPACE ONLY 36c SPACE ONLY 38a SPACE ONLY 40b SPACE ONLY 42c SPACE ONLY TOTAL 12/5/2013 2A7-3.XLS 177.0 193.4 195.9 ELECTRICAL PANEL SCHEDULE SUB 35 Panel Designation 2A7-4 Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer 100A 225A, 208Y/120V, 3 PH, 4W 10KAIC 09-120-E4S35 CEI/B.MAXWELL Location, bldg. 9-120.2 col. A/7 Date Installed Feeder Size 1-1/4"-4#2 & 1#8G Fed From 2A7-3 Revised Ckt NEW PANEL Date Revised 12/05/13 Job Number 131174-00 Ckt Breaker Type Frame Trip Wire Size Load Served Load Amps Ph A Ph B Ph C Location la THQB 20A #12 RECEPTACLES 6.0 OFF 21A5 3b THQB 20A #12 RECEPTACLES 6.0 OFF 21A5 5c THQB 20A #12 RECEPTACLES 6.0 OFF 24A5 7a THQB 20A #12 RECEPTACLES OFF 24A5 9b THQB 20A #12 RECEPTACLES 6.0 MANAGER 23A5 11c THQB 20A #12 RECEPTACLES 6.0 MANAGER 23A6 13a THQB 20A #12 RECEPTACLES 6.0 PRINTER 24A6 15b THQB 20A #12 PRINTER 6.0 PRINTER 24A6 17c THQB 20A #12 MONITORS 6.0 CONFERENCE 23A8 19a THQB 20A #12 MOTORIZED SHADES 10.0 CONF 23A8 21b THQB 20A #12 MONITORS CONF 23A8 23c THQB 20A #12 RECEPTACLES 7.5 CONF 23A8 25a THQB 20A #12 MONITORS 6.0 CONF 21A8 27b THQB 20A #12 RECEPTACLES 4.5 CONF 21A8 29c THQB 20A #12 RECEPTACLES 4.5 PHONES 22A7, 23A7 31a THQB 20A #12 RECEPTACLES 6.0 PLOTTER 2388 33b 35c 37a 39b THQB THQB THQB THQB 20A 20A 20A 20A #12 #12 #12 #12 PRINTER PLOTTER PROJECTOR PROJECTOR 6.0 12.0 6.0 12.0 PLOTTER 23B8 PLOTTER 23B8 CONF 23A8 CONF 23A8 41c THQB 20A #12 PROJECTOR 6.0 CONF 23A8 2a THQB 20A #12 RECEPTACLES 6.0 !.. 22A8, 22B8 4b THQB 20A #12 RECEPTACLES 6.0 22A8, 22B8 6c THQB 20A #12 RECEPTACLES 6.0 2188, 22B8 8a THQB 20A #12 RECEPTACLES 4.5 2168, 22A8, 22B8 10b THQB 20A #12 MONITORS 6.0 CORRIDOR 12c THQB 20A #12 RECEPTACLES 3.0 CORRIDOR 14a THQB 20A SPARE C.B. 16b THQB 20A #12 RECEPTACLES COLLAB 21C8 18c THQB 20A #12 RECEPTACLES 3.0 COLLAB 21C8 20a THQB 20A #12 RECEPTACLES 3.0 PHONE 22C4, 23C4 22b THQB 20A #12 REFRIGERATOR 6.0 COLLAB 21C8 24c THQB 20A #12 REFRIGERATOR 6.0 COLLAB 21C8 26a THQB 20A #12 MONITORS CONF 23A8 28b THQB 20A #12 AV CABINET 3.0 CONF 23A8 30c THQB 20A #12 RECEPTACLES 6.0 CONF 23A8 32a THQB 20A SPARE C.B. 34b THQB 20A SPARE C.B. 36c THQB 20A SPARE C.B. 38a THQB 20A SPARE C.B. 40b THQB 20A #12 RECEPTACLES 3.0 MAIN ELECT 23A6 42c THQB 20A SPARE C.B. TOTAL 12/5/2013 2A7-4.XLS 59.5 75.0 72.0 ELECTRICAL PANEL SCHEDULE SUB 35 Panel Designation 2A7-5 Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer 100A 225A, 208Y/120V, 3 PH, 4W 10KAI C 09-120-E4S35 CEI/B.MAXWELL Location, bldg. 9-120.2 col. A/7 Date Installed Feeder Size 1-1/4"-4#2 & 1#8G Fed From 2A7-3 Revised Ckt NEW PANEL Date Revised 12/05/13 Job Number 131174-00 Ckt Breaker Type Frame Trip Wire Size Load Served Ph Load Amps A Ph B I Ph C Location 1a THQB 20A #12 WORKSTATION 7.5 ?: OPEN OFF 21C7 3b THQB 20A #12 WORKSTATION OPEN OFF 21C7 5c THQB 20A #12 WORKSTATION 5.0 OPEN OFF 21C7 7a THQB 20A #12 WORKSTATION 5.0 OPEN OFF 21C7 9b THQB 20A #12 WORKSTATION OPEN OFF 21C7 11c THQB 20A #12 WORKSTATION 5.0 OPEN OFF 21C7 13a THQB 20A #12 WORKSTATION 5.0 OPEN OFF 21C7 15b 17c THQB THQB 20A 20A #12 #12 WORKSTATION WORKSTATION 5.0 5.0 OPEN OFF 21C7 OPEN OFF 21C7 19a THQB 20A #12 WORKSTATION 5.0 OPEN OFF 21C7 21 b THQB 20A #12 WORKSTATION 50 OPEN OFF 21C7 23c 25a 27b THQB THQB THQB 20A 20A 20A #12 #12 #12 WORKSTATION WORKSTATION WORKSTATION 5.0 5.0 5.0 OPEN OFF 21C7 OPEN OFF 2105 OPEN OFF 2105 29c THQB 20A #12 WORKSTATION 5.0 OPEN OFF 2105 31a THQB 20A #12 WORKSTATION 5.0 OPEN OFF 2105 33b THQB 20A #12 WORKSTATION 5.0 OPEN OFF 2105 35c THQB 20A #12 RECEPTS 3.0 COLUMN C5 37a THQB 20A SPARE C.B. COLUMN C5 39b THQB 20A SPARE C.B. COLUMN C5 41c THQB 20A SPARE C.B. COLUMN C5 2a THQB 20A #12 WORKSTATION 5.0 COLUMN B7 4b THQB 20A #12 WORKSTATION 5.0 COLUMN B7 6c THQB 20A #12 WORKSTATION 5.0 COLUMN B7 8a 10b 12c THQB THQB THQB 20A 20A 20A #12 #12 #12 WORKSTATION MONITORS WORKSTATION 5.0 5.0 5.0 COLUMN B7 COLUMN B7 COLUMN B7 14a THQB 20A #12 WORKSTATION 5.0 COLUMN B7 1 6b THQB 20A #12 WORKSTATION 5.0 COLUMN B7 18c THQB 20A #12 MONITORS 6.0 COLUMN B7 20a THQB 20A #12 WORKSTATION 5.0 COLUMN C6 22b THQB 20A #12 WORKSTATION 5.0 COLUMN C6 24c THQB 20A #12 MONITORS 6.0 COLUMN C6 26a THQB 20A #12 WORKSTATION 5.0 COLUMN C6 28b THQB 20A #12 WORKSTATION 5.0 COLUMN C6 30c THQB 20A #12 MONITORS 6.0 COLUMN C6 32a THQB 20A #12 WORKSTATION COLUMN C6 34b 36c 38a THQB THQB THQB 20A 20A 20A #12 #12 WORKSTATION MONITORS SPARE C.B. 5.0 5.0 COLUMN C6 COLUMN C6 COLUMN C5 40b THQB 20A SPARE C.B. COLUMN C5 42c THQB 20A SPARE C.B. COLUMN C5 12/5/2013 2A7-5.XLS TOTAL 62.5 60.0 61.0 ELECTRICAL PANEL SCHEDULE Panel Designation 2A7-6 Location, bldg. 9-120.2 Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer 100A 225A, 208Y/120V, 3 PH, 4W 10KAIC 09-120-E4S35 CEI/B.MAXWELL col. A/7 Date Installed Feeder Size SUB 35 1-1/4"-4#2 & 1#8G Fed From 2A7-3 Revised Ckt NEW PANEL Date Revised 12/05/13 Job Number 131174-00 Ckt Breaker Type Frame Trip Wire Size Load Served Load Amps Ph A Ph B Ph C Location 1a THQB 20A #12 MONITORS 6.0 PROJECT 22A5 3b 5c 7a THOB THQB THQB 20A 20A 20A #12 #12 #12 MONITORS RECEPTACLES MONITORS 6.0 6.0 6.0 PROJECT 22A6 22A5,22A6 PROJECT 21B5 9b THQB 20A #12 MONITORS 6.0 PROJECT 21 B6 11c THQB 20A #12 RECEPTACLES 6.0 21B5, 21B6 13a THQB 20A #12 RECEPTACLES RESTRM 21H7, 22H7 15b THQB 20A #12 RECEPTACLE RESTRM 21H7, 22H7 17c THQB 20A #12 DRINKING FOUNTAIN, AUTO VALVE RESTRM 21H7, 22H7 19a THQB 20A #12 RECEPTACLES 4.5 PROJECT 23B6 21b THQB 20A #12 MONITORS 6.0 PROJECT 23B6 23c THQB 20A #12 RECEPTACLES 4.5 PROJECT 2106 25a THQB 20A #12 MONITORS 6.0 PROJECT 2106 27b THQB 20A #12 RECEPTACLES 45 PROJECT 22C6 29c 31a 33b THQB THQB THQB 20A 20A 20A #12 #12 MONITORS SPARE C.B. INSTA-HOT 6.3 6.0 PROJECT 22C6 COLLAB 21C8 35c THQB 20A #12 WATER HEATER 13.8 COLLAR 21C8 37a THQB 20A #12 MICROWAVE 10.0 COLLAB 21C8 39b THQB 20A #12 MICROWAVE 10.0 COLLAR 21C8 41c THQB 20A #12 COFFEE MAKER 8.3 COLLAB 21C8 2a THQB 20A #12 AC2D4 - MECH EQUIPMENT 0.7 DATA RM 22D6 4b 2P 0.7 6c THQB 20A #12 CONDENSATE PUMP 1.0 DATA RM 22D6 8a THQB 20A #12 EF2B9 - MECH EQUIPMENT 5.8 MECH RM 24B8 10b THQB 20A #12 RECEPTACLE 1.5 MECH RM 24B8 12c THQB 20A #12 EF2A7 - MECH EQUIPMENT 5.8 MAIN ELEC 23A6 14a THQB 20A #12 METER CABINET 1.0 MAIN ELEC 23A6 16b THQB 20A #10 EFRH7 - MECH EQUIPMENT 8.4 18c THQB 20A #12 CMCS PANEL 2.5 ROOM 23A6 20a THQB 20A #12 RECEPTACLE -EQUIPMENT RACK 3.0 DATA RM 22D6 22b 24c THQB THQB 20A 20A #12 #12 RECEPTACLE -EQUIPMENT RACK RECEPTACLE -EQUIPMENT RACK 3.0 3.0 DATA RM 22D6 DATA RM 22D6 26a THQB 20A #12 RECEPTACLE -EQUIPMENT RACK 3.0 DATA RM 22D6 28b 30c THQB THQB 20A 20A #12 #12 RECEPTACLE -EQUIPMENT RACK RECEPTACLE -EQUIPMENT RACK 3.0 3.0 DATA RM 22D6 DATA RM 22D6 32a THQB 20A #12 RECEPTACLE -EQUIPMENT RACK 3.0 DATA RM 22D6 34b THQB 20A #12 RECEPTACLE -EQUIPMENT RACK 3.0 DATA RM 22D6 36c THQB 20A #12 RECEPTACLE -EQUIPMENT RACK 3.0 DATA RM 22D6 38a THQB 20A #12 RECEPTACLES 6.0 DATA RM 22D6 40b AHU RECEPTS & LTG 42c SPACE ONLY TOTAL 12/5/2013 2A7-6.XLS 55.0 58.4 62.9 ELECTRICAL PANEL SCHEDULE SUB 35 Panel Designation Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer 2B2-1 50A 225A, 480Y/277V, 3 PH, 4W 14kAIC 09-120-E4S35 CEI/B.MAXWELL Location, bldg. 9-120.2 col. B/2 Date Installed Feeder Size 1 "-4#6 & 1#8G Fed From 2F2-3 Revised Ckt NEW PANEL Date Revised 12/05/13 Job Number 131174-00 Ckt Breaker Type Frame Trip Wire Size Load Served Load Amps Ph A Ph B Ph C Location 1a THQB 20A #12 LIGHTING 10.6 NORHT OFFICES 3b THOB 20A #12 LIGHTING CORRIDORS 5c THQB 20A #12 LIGHTING 6.5 RECEPTTION 7a THQB 20A #12 LIGHTING 11.2 ........... ................ SOUTH OFFICES 9b 11c THQB THQB 20A 20A #12 #12 LIGHTING LIGHTING 4.2 12.1 SOUTH OFFICES OPEN OFFICE 13a THQB 20A #12 LIGHTING 4.2 OPEN OFFICE 15b THQB 20A #12 LIGHTING 14.3 OPEN OFFICE 17c THQB 20A #12 LIGHTING 2.8 HALLWAY 2107 19a THQB 20A SPAREC.B. 21b THQB 20A SPAREC.B. 23c THQB 20A #12 LIGHTING 3.3 EMERG 25a SPACE ONLY 27b SPACE ONLY 29c SPACE ONLY 31a SPACE ONLY 33b SPACE ONLY 35c SPACE ONLY 37a SPACE ONLY 39b SPACE ONLY 41c SPACE ONLY 2a THQB 20A SPARE C.B. 4b THQB 20A SPARE C.B. 6c THQB 20A SPARE C.B. 8a THQB 20A SPARE C.B. 10b THQB 20A SPARE C.B. 12c THQB 20A SPARE C.B. 14a THQB 20A SPARE C.B. 16b THQB 20A SPARE C.B. 18c THQB 20A SPARE C.B. 20a THQB 20A SPARE C.B. 22b THQB 20A SPARE C.B. 24c THQB 20A SPARE C.B. 26a SPACE ONLY 28b SPACE ONLY 30c SPACE ONLY 32a SPACE ONLY 34b SPACE ONLY 36c SPACE ONLY 38a SPACE ONLY 40b SPACE ONLY 42c SPACE ONLY TOTAL 12/5/2013 2B2-1.XLS 26.0 26.8 24.7 LCP-282-1 LOW VOLTAGE LIGHTING CONTROL PANEL LV. LTG. CONTROL POWER CKT. 100% CONSTRUCTION -12.05.2013 LOW VOLTAGE LIGHTING CONTROL PANEL LCP-282-1 PANEL NO. COLUMN LOCATION RELAY NO. CKT. NO. AREA CONTROLLED DWG. SWITCHING LOCATION I REMARKS 2B2-1 C/1-C/3 R1 5c LOBBY RIBBON 2E10 C/3 OVER RIDE 2B2-1 C/1-C/3 R2 5c LOBBY GENERAL 2E10 C/3 OVER RIDE 282-1 C/1-C/3 R3 5c LOBBY ACCENT 2E10 C/3 OVER RIDE 2B2-1 A/D-1/4 R4 3b GENERAL 2E10 C/3 OVER RIDE 2B2-1 A/D-5/9 R5 13a OPEN OFFICE WALL WASH 2E12 C/3 OVER RIDE 2B2-1 A/D-1/4 R6 3b OFFICE ASSISTANT 2E10 C/3 OVER RIDE 2B2-1 A/D-1/4 R7 5c EAST ACCENT WALL 2E10 C/3 OVER RIDE 2B2-1 A/D-1/4 R8 3b WEST CORRIDOR NORTH 2E10 C/3 OVER RIDE 2B2-1 A/D-1/4 R9 3b DAYLIGHT ZONE R28 2E10 C/3 DAYLIGHTING 2B2-1 A/D-1/4 R10 5c RECEPTION/WAITING 2E10 C/3 OVER RIDE 2B2-1 A/D-1/4 R11 5c LRG CONF CLOUD 2E10 C/3 OVER RIDE 2B2-1 A/D-1/4 R12 5c LRG CONF ACCENT 2E10 C/3 OVER RIDE 2B2-1 A/D-1/4 R13 3b OFFICE ASSISTANT 2E10 C/3 OVER RIDE 2B2-1 A/D-5/9 R14 15b SM CONF NORTH CLOUD 2E12 A/7,D/8 OVER RIDE 2B2-1 A/D-S/9 R15 15b SM CONF NORTH ACCENT 2E12 A/7,D/8 OVER RIDE 2B2-1 A/D-5/9 R16 15b SM CONF SOUTH CLOUD 2E12 A/7,D/8 OVER RIDE 2B2-1 A/D-5/9 R17 15b SM CONF SOUTH ACCENT 2E12 A/7,D/8 OVER RIDE 282-1 A/D-5/9 R18 15b WEST CORRIDOR SOUTH 2E12 A/7,D/8 OVER RIDE 2B2-1 A/D-5/9 R19 15b OPEN OFFICE NORTH 2E10, 2E12 AR,C/3,D/8 OVER RIDE 2B2-1 A/D-5/9 R20 11c OPEN OFFICE SOUTH 2E12 A/7,D/8 OVER RIDE 2B2-1 A/D-1/9 R21 EM/28b EMERGENCY LIGHTING 2E10, 2E12, 2E13 AUTO ON - OCC SENSOR OVER RIDE 2132-1 AID-1/4 R22 3b DAYLIGHT ZONE R22 2E10 C/3 DAYLIGHTING 282-1 A/D-5/9 R23 17c BOH CIRCULATION 2E12, 2E13 A/7,D/8 OVER RIDE 2B2-1 A/D-1/4 R24 5c LOBBY COLUMN ACCENT 2E10 C13 OVER RIDE 2B2-1 A/D-1/4 R25 5c WEST ACCENT WALL 2E10 C/3 OVER RIDE 262-1 R26 282-1 R27 2B2-1 R28 282-1 R29 262-1 R30 2B2-1 R31 2B2-1 R32 2B2-1 R33 2B2-1 R34 2B2-1 R35 2B2-1 R36 282-1 R37 2B2-1 R38 282-1 R39 2B2-1 R40 2B2-1 R41 2B2-1 R42 2B2-1 R43 262-1 R44 2B2-1 R45 262-1 R46 2B2-1 R47 2B2-1 R48 12/5/2013 Page 1 ELECTRICAL PANEL SCHEDULE SUB 35 Panel Designation 2B2-2 Location, bldg. 9-120.2 col. B/2 Panel Type Date Installed Main Bkr Rating 225A Feeder Size 2-1/2"-4#4/0 & 1#2G Panel Rating 225A, 208Y/120V, 3 PH, 4W Fed From 2A7-1 VIA 75KVA XFMR Ref. Dwg.No. Revision Engineer 10KAI C 09-120-E4S35 CEI/B.MAXWELL Revised Ckt NEW PANEL Date Revised 12/05/13 Job Number 131174-00 Ckt 1a 3b 5c Breaker Type Frame Irrip 100A Wire Size #2 2B2-3 Load Served Load Amps Ph A Ph B 63.0 Ph C Location 69.0 69.6 7a 9b 11c 100A #2 2B2-5 32.0 20.0 20.0 13a SPACE ONLY 15b SPACE ONLY 17c SPACE ONLY 19a SPACE ONLY 21b SPACE ONLY 23c SPACE ONLY 25a SPACE ONLY 27b SPACE ONLY 29c SPACE ONLY 31a SPACE ONLY 33b SPACE ONLY 35c SPACE ONLY 37a SPACE ONLY 39b SPACE ONLY 41c SPACE ONLY 2a 4b 6c 100A #2 2B2-4 73.8 65.8 57.0 8a 10b 12c 100A SPARE C.B. 14a SPACE ONLY 16b SPACE ONLY 18c SPACE ONLY 20a SPACE ONLY 22b SPACE ONLY 24c SPACE ONLY 26a SPACE ONLY 28b SPACE ONLY 30c SPACE ONLY 32a SPACE ONLY 34b SPACE ONLY 36c SPACE ONLY 38a SPACE ONLY 40b SPACE ONLY 42c SPACE ONLY TOTAL 12/5/2013 2B2-2.XLS 168.8 154.8 146.6 ELECTRICAL PANEL SCHEDULE Panel Designation 2B2-3 Location, bldg. col. Date Installed Feeder Size Fed From Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer 100A 225A, 208Y/120V, 3 PH, 4W 10KAIC 09-120-E4S35 CEI/B.MAXWELL Revised Ckt Date Revised Job Number SUB 35 9-120.2 B/2 1-1 /4"-4#2 & 1#8G 2B2-2 NEW PANEL 12/05/13 131174-00 Ckt 1a Breaker Type Frame THQB Trip 20A Wire Size #12 Load Served SPARE C.B. Lo Ph A ad Amps Ph B I Ph C Location 3b THQB 20A #12 MOTORIZED SHADES 10.0 CONF 25A2 5c THQB 20A #12 MOTORIZED SHADES 10.0 OFF 26A2 7a THQB 20A #12 RECEPTACLES 9.0 25A1, 21A2, 26A2 9b 11c THQB THQB 20A 20A #12 #12 RECEPTACLES RECEPTACLES 9.0 9.0 25A1, 21A2, 26A2 25A1, 21A2, 26A2 13a THQB 20A #12 WALL MOUNTED MONITORS 6.0 CONF 25A2 15b THQB 20A #12 RECEPTACLES 4.5 CONF 25A2 17c 19a 21b THQB THQB THQB 20A 20A 20A #12 #12 #12 RECEPTACLES RECEPTACLES RECEPTACLES 6.0 6.0 7.5 21A3, 24A3 21A3, 24A3 21A3, 24A3 23c THQB 20A #12 REFRIGERATOR 5.6 PANTRY 22A1 25a THQB 20A #12 RECEPTACLES 6.0 PANTRY 22A1 27b THQB 20A #12 RECEPTACLES 6.0 HOTEL 23A1 29c THQB 20A #12 RECEPTACLES 7.5 HOTEL 24A1 31a THQB 20A #12 RECEPTACLES 6.0 22A2, 22B2 33b THQB 20A #12 RECEPTACLES 6.0 22A2, 22B2 35c THQB 20A #12 RECEPTACLES 7.5 21 B2, 22A2, 22B2 37a THQB 20A #12 MONITORS 6.0 21B2, 22B2 39b THQB 20A SPARE C.B. 41c THQB 20A SPARE C.B. 2a THQB 20A SPARE C.B. 4b THQB 20A #12 PRINTER 8.0 PLOTTER 22A3 6c THQB 20A #12 RECEPTACLES 3.0 OFF 23A3 8a THQB 20A #12 RECEPTACLES OFF ASSIST 23A3 10b THQB 20A #12 RECEPTACLES 4.5 PROJECT 23B3 12c THQB 20A #12 MONITORS 6.0 PROJECT 23B3 14a THQB 20A #12 RECEPTACLES 6.0 OFF 21B3 16b THQB 20A #12 MONITORS 6.0 OFF 21B3 18c THQB 20A #12 RECEPTACLES 9.0 PROJ 23A2, 24A2 20a THQB 20A #12 MONITORS 6.0 PROJ 23A2 22b THQB 20A #12 MONITORS 6.0 PROJECT 24B2 24c THQB 20A #12 RECEPTACLES 4.5 PROJECT 24B2 26a THQB 20A #12 MONITORS 6.0 ....,:... PROJECT 24A2 28b THQB 20A #12 FLOOR RECEPTS 3.0 25A2 30c THQB 20A SPACE ONLY 32a THQB 20A SPARE C.B. 34b THQB 20A SPARE C.B. 36c THQB 20A SPARE C.B. 38a THQB 20A SPARE C.B. 40b THQB 20A SPARE C.B. 42c THQB 20A SPARE C.B. TOTAL 12/5/2013 2B2-3.XLS 63.0 69.0 69.6 ELECTRICAL PANEL SCHEDULE SUB 35 Panel Designation 2B2-4 Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer 100A 225A, 208Y/120V, 3 PH, 4W 10KAIC 09-120-E4S35 CEI/B.MAXWELL Location, bldg. 9-120.2 col. B/2 Date Installed Feeder Size Fed From 1-1/4"-4#2 & 1#8G 2B2-2 Revised Ckt NEW PANEL Date Revised 12/05/13 Job Number 131174-00 Ckt Breaker Type Frame Trip Wire Size Load Served Load Amps Ph A Ph B Ph C Location 1a THQB 20A #12 PROJECTOR SCREEN 2.0 CONF 21B4 3b THQB 20A #12 MONITORS 6.0 CONF 21B4 5c THQB 20A #12 RECEPTACLES 4.5 CONF 21B4 7a THQB 20A #12 MONITORS 6.0 RECEPTION 22B3 9b THQB 20A #12 RECEPTACLES 6.0 RECEPTION 22B3 11c THQB 20A SPARE C.B. 13a THQB 20A SPARE C.B. 15b THQB 20A SPARE C.B. 17c THQB 20A SPARE C.B. 19a THQB 20A #12 RECEPTACLES 4.5 ... CONF 21C4 21b THQB 20A #12 MONITORS 6.0 CONF 21C4 23c THQB 20A #12 RECEPTACLES 1.5 RECEPTION 2263 25a THQB 20A #12 RECEPTACLES COLLAB 21 A4 27b THQB 20A #12 RECEPTACLES 6.0 COLLAB 21A4 29c THQB 20A #12 MONITORS 9.0 COLLAB 21A4 31a THQB 20A #12 DISH WASHER 10.0 PANTRY 22A1 33b THQB 20A #12 INSTA HOT 6.3 PANTRY 22A1 35c 37a THQB THQB 20A 20A #12 #12 MICROWAVE COFFEE MAKER 12.5 PANTRY 22A1 PANTRY 22A1 39b THQB 20A #12 MONITORS 6.0 PANTRY 22A1 41c THQB 20A #12 REFRIGERATOR PANTRY 22A1 2a THQB 20A #12 PROJECTOR 8.0 CONF 21B4 4b 6c THQB THQB 20A 20A #12 #12 PROJECTOR PROJECTOR 80 8.0 CONF 21B4 CONF 21B4 8a THQB 20A #12 MONITORS 6.0 CONF 21A1 10b THQB 20A #12 RECEPTACLES 4.5` CONF 21A1 12c THQB 20A #12 RECEPTACLES 4.5 CONF 21A1 14a THQB 20A #12 PROJECTOR 8.0 CONF 21A1 16b THQB 20A #12 PROJECTOR CONF 21A1 18c THQB 20A #12 MOTORIZED SHADES 8.0 CONF 21A1 20a THQB 20A #12 MONITORS ................ 9.0 LOBBY 23B2 22b THQB 20A #12 MONITORS 6.0`.! LOBBY 2362 24c THQB 20A #12 PROJECTOR 9.0 LOBBY 23B2 26a THQB 20A #12 MONITORS 6.0 CONF 21A1 28b THQB 20A #12 FLOOR MOUNTED RECEPTS CONF 21A1 30c THQB 20A SPARE C.B. 32a THQB 20A SPARE C.B. 34b THQB 20A SPARE C.B. 36c THQB 20A SPARE C.B. 38a THQB 20A SPARE C.B. 40b THQB 20A SPARE C.B. 42c THQB 20A SPARE C.B. TOTAL 12/5/2013 2B2-4.XLS 73.8 65.8 57.0 ELECTRICAL PANEL SCHEDULE Panel Designation 2B2-5 Location, bldg. 9-120.2 Panel Type Main Bkr Rating Panel Rating Ref. Dwg.No. Revision Engineer 100A 225A, 208Y/120V, 3 PH, 4W 10KAIC 09-120-E4S35 CEI/B.MAXWELL col. B/2 Date Installed Feeder Size SUB 35 1-1/4"-4#2 & 1#8G Fed From 2B2-2 Revised Ckt NEW PANEL Date Revised 12/05/13 Job Number 131174-00 Ckt Breaker Type Frame Trip Wire Size Load Served Load Amps Ph A Ph B Ph C Location la THQB 20 #12 WORKSTATION 5.0 3b THQB 20 #12 WORKSTATION 5.0 5c THQB 20 #12 WORKSTATION 5.0 7a THQB 20 #12 WORKSTATION 5.0 9b THQB 20 #12 WORKSTATION 5.0 11c THQB 20 #12 WORKSTATION 5.0 13a THQB 20 #12 MONITORS 6.0 15b THQB 20 SPARE C.B. 17c THQB 20 SPARE C.B. 19a THQB 20 SPARE C.B. 21b THQB 20 SPARE C.B. 23c THQB 20 SPARE C.B. 25a THQB 20 SPARE C.B. 27b THQB 20 SPARE C.B. 29c THQB 20 SPARE C.B. 31a THQB 20 SPARE C.B. 33b THQB 20 SPARE C.B. 35c THQB 20 SPARE C.B. 37a THQB 20 SPARE C.B. 39b THQB 20 SPARE C.B. 41c THQB 20 SPARE C.B. 2a THQB 20 #12 WORKSTATION 4b THQB 20 #12 WORKSTATION 5.0 6c THQB 20 #12 WORKSTATION 5.0' 8a THQB 20 #12 WORKSTATION 5.0 10b THQB 20 #12 WORKSTATION 5.0 12c 14a THQB THQB 20 20 #12 #12 WORKSTATION MONITORS 5.0 5.0 16b THQB 20 SPARE C.B. 6.0 18c THQB 20 SPARE C.B. 20a THQB 20 SPARE C.B. 22b THQB 20 SPARE C.B. 24c THQB 20 SPARE C.B. 26a THQB 20 SPARE C.B. 28b THQB 20 SPARE C.B. 30c THQB 20 SPARE C.B. 32a THQB 20 SPARE C.B. 34b THQB 20 SPARE C.B. 36c THQB 20 SPARE C.B. 38a THQB 20 SPARE C.B. 40b THQB 20 SPARE C.B. 42c THQB 20 SPARE C.B. TOTAL 12/5/2013 2B2-5.XLS 32.0 20.0 20.0 ELECTRICAL PANEL SCHEDULE SUB 75 Panel Designation 2F2-1 Panel Type GE Main Bkr Rating Panel Rating 800A, 480Y/277V, 3 PH, 4W 18k AIC Ref. Dwg.No. Revision Engineer 09-120-E4S75 B B. MAXWELL Location, bldg. 9-120.2 col. F/2 Date Installed Feeder Size (2)3.5"-3#300kCMIL & 1#1G Fed From SUBSTATION NO. 75 - F3 Revised Ckt 2a,4b,6c (SHOWN BOLD) Date Revised 12/05/13 Job Number J#131174-00 Ckt Breaker Type Frame Trip Wire Size Load Served Load Amps Ph A Ph B Ph C Location la 3b 5c 225A 3P #4/0 #4/0 #4/0 PANEL 2F2-2 • ROOM 24G2 ROOM 24G2 ROOM 24G2 7a 9b 11c 450A 3P PANEL 2F2-4 VIA 225KVA XFMR ROOM 24G2 ROOM 24G2 ROOM 24G2 13a SPACE ONLY 15b SPACE ONLY 17c SPACE ONLY 19a SPACE ONLY 21b SPACE ONLY 23c SPACE ONLY 25a SPACE ONLY 27b SPACE ONLY 29c SPACE ONLY 31a SPACE ONLY 33b SPACE ONLY 35c SPACE ONLY 37a SPACE ONLY 39b SPACE ONLY 41c SPACE ONLY 2a 4b 6c 70A 3P #4 #4 #4 PANEL 2F2-3 ROOM 24G2 ROOM 24G2 ROOM 24G2 8a SPACE ONLY 10b SPACE ONLY •• • 12c SPACE ONLY 14a SPACE ONLY 16b SPACE ONLY 18c SPACE ONLY .• . 20a SPACE ONLY 22b SPACE ONLY 24c SPACE ONLY 26a SPACE ONLY 28b SPACE ONLY 30c SPACE ONLY 32a SPACE ONLY 34b SPACE ONLY 36c SPACE ONLY 38a SPACE ONLY 40b SPACE ONLY 42c SPACE ONLY TOTAL 12/5/2013 2F2-1.XLS ELECTRICAL PANEL SCHEDULE Panel Designation 2F2-2 Panel Type GE ITEM Main Bkr Rating Panel Rating 225A, 480V, 3 PH, 3W 18kAIC Ref. Dwg.No. 09-120-E4S75 Revision Engineer B B. MAXWELL Location, bldg. 9-120.2 SUB 75 col. F/2 Date Installed Feeder Size 2.5"-3#4/0 & 1 #4G Fed From 2F2-1 /1 a,3b,5c Revised Ckt (SHOWN BOLD) Date Revised 12/05/13 Job Number J#131174-00 Breaker Type Ckt 1a 3b 5c 7a 9b 11c Frame THED THED Trip 150A 3P 90A 3P Wire Size #1/0 Load Served AHRG2 Ph Load Amps A Ph B jPh C 84.0 Location 3G2 #1/0 AHRG2 84.0 .. 3G2 #1/0 #3 AHRG2 AHRG4 58.0 84.0 3G2 3G5 #3 AHRG4 58.0 'i':;' 3G5 #3 AHRG4 58.0 3G5 13a 15b 17c THED 90A 3P #3 AHRF5 50.0 3F5 #3 AHRF5 50.0 3F5 #3 AHRF5 50.0 3F5 19a SPACE ONLY 21b SPACE ONLY 23c SPACE ONLY 25a 27b 29c 31a 33b 35c 37a 39b 41c 2a 4b 6c THED 20A 3P SPARE C.B. SPARE C.B. SPARE C.B. 8a 10b 12c THED 20A 3P SPARE C.B. SPARE C.B. SPARE C.B. 14a 16b 18c THED 20A 3P SPARE C.B. SPARE C.B. SPARE C.B. 20a SPACE ONLY 22b SPACE ONLY 24c SPACE ONLY 26a 28b 30c 32a 34b 36c 38a 40b 42c TOTAL 12/5/2013 2F2-2.XLS 192.0 192.0 192.0 ELECTRICAL PANEL SCHEDULE SUB 75 Panel Designation 2F2-3 Location, bldg. 9-120.2 col. F/2 Panel Type GE Date Installed Main Bkr Rating Feeder Size 1 1/4"-4#4 & 1#8 G 0 Panel Rating 225A, 480Y/277V, 3 PH, 4W Fed From 2F2-1/2a,4b,6c Ref. Dwg.No. Revision Engineer 09-120-E4S75 B B. MAXWELL Revised Ckt Q Date Revised 12/05/13 Job Number J#131174-00 Ckt la Breaker Type Frame THQB Trip 20A Wire Size #12 Load Served LIGHTS- ELEV LOBBY, LOBBY, VIEW RM #1 Ph Load Amps A Ph B I Ph C 9.1 Location 2ND FLOOR 3b THQB 20A #12 LIGHTS -OFFICES 6.0 2ND FLOOR 5c THQB 20A #12 LIGHTS-COORIDOR 4.1 2ND FLOOR 7a THQB 20A #12 LIGHTS - INNOVATION WORK SPACE 6.0 .............. 2ND FLOOR 9b THQB 20A SPARE C.B. 11c THQB 20A SPARE C.B. 13a THQB 20A SPARE C.B. 15b THQB 20A SPARE C.B. 17c THQB 20A SPARE C.B. 19a THQB 20A SPARE C.B. 21b THQB 20A SPARE C.B. 23c THQB 20A SPARE C.B. 25a THQB 20A SPARE C.B. 27b THQB 20A SPARE C.B. 29c THQB 20A SPARE C.B. 31a THQB 20A SPARE C.B. 33b THQB 20A SPARE C.B. 35c THQB 20A SPARE C.B. m Q 0 37a 39b 41c 50A #6 2B2-1 26.0 26.8 24.7 2a THQB 20A #12 LIGHTS-STOR, TOILETS, JANITOR 6.5 2ND FLOOR 4b THQB 20A #12 LIGHTS -VIEW RMS # 2,3,4,5 10.6 2ND FLOOR 0 THQB THQB THQB THQB THQB THQB THQB THQB THQB THQB THQB THQB THQB THQB THQB 12/5/2013 2F2-3.XLS 6c 8a 10b 12c 14a 16b 18c 20a 22b 24c 26a 28b 30c 32a 34b 36c 38a 40b 42c THQB THQB THQB THQB 20A #12 LTG - STOR, TOILTES, JANITOR 4.3 RESTROOMS 20A SPARE C.B. 20A SPARE C.B. 20A SPARE C.B. 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A SPARE C.B. SPARE C.B. SPARE C.B. SPARE C.B. SPARE C.B. SPARE C.B. SPARE C.B. SPARE C.B. SPARE C.B. SPARE C.B. SPARE C.B. SPARE C.B. SPARE C.B. SPARE C.B. SPARE C.B. TOTAL 47.6 43.4 33.1 STAND-BY EMERGENCY PANEL SCHEDULE SUB 28 Panel Designation XSK3 (OLD 8N) Location, bldg. 9-120.1 This panel feeds ADT Circuits -Notify Fire Department col. K3 Panel Type IEM 'PIE' Date Installed 1 /1 /1995 Main Bkr Rating 100A THED Feeder Size 2-1,4°C, 4-#2 Panel Rating 480Y/277V, 3PH, 4W, 60Hz, 225A Fed From XSE8/2abc Via 9-101 Ref. Dwg.No. 9-120-1E61 Revised Ckt 0 Revision C Date Revised 12/05/13 Engineer B. MAXWELL Job Number 131174-00 Ckt Breaker Type Frame Trip Wire Size Load Served Load Amps Ph A Ph B Ph C Location 1a THED 20 12 ADT.5kV X-FO ADT PNL @ B1 & C5, LTG -NW STAIRWAY 1st FLOOR 3b THED 20 12 LIGHTS 1st FLOOR 5c THED 20 12 SEC. ALARM IN 13C3, Lights Mech/Elec RM 1st FLOOR 7a THED 20 SPARE S 9b THED 20 SPARE 11c THED 20 SPARE 13a 15b 17c 19a 21b 0 23c 25a 27b THED-3P 29c 31a THED-3P THED-2P THED 30 40 20 20 10 10 10 4 4 4 8 8 PANEL XSK3A VIA 15 KVA XFMR PANEL XSC7 PANEL XSSUB#75 LOCATED INSIDE SUBSTATION #75 2p bkr takes 3p position SPARE K-3 C-7 OUTDR SUB AT E.5/9 33b THED 20 SPARE 35c 37a THED THED 20 20 SPARE SPARE 39b THED 20 SPARE 41c THED 20 SPARE 2a THED 20 12 SPARE 4b THED 20 12 SPARE 6c THED 20 12 SPARE 8a THED 20 12 SW STAIRWAY #4 LTG 10b THED 20 12 SQ D LOAD CNTR VIA 5kVA XFMR SECURITY F/3 12c THED 20 12 2nd FLR LTS & EXIT SIGN 14a 16b 18c THED-2P 30 10 10 120/240V PANEL X2K2 VIA 10 KVA 1 PH XFMR K-2 2ND FL 20a 22b 24c THED 20 8 8 8 FEEDS ADT PANEL PANEL XSJ8 VIA 15kVA XFMR 26a THED 20 10 2ND FLOOR EMERGENCY LIGHT 2.2 SECOND FLOOR 28b THED 20 10 2ND FLOOR EMERGENCY LIGHTS (EXIT & 24HR) 1.1 SECOND FLOOR 30c THED 20 SPARE 32a 34b THED THED 20 20 SPARE SPARE 36c THED 20 SPARE 38a THED 20 SPARE 4Db THED 20 SPARE 42c THED 20 SPARE OFF HOURS INSPECTION Reimbursement authorization/approval to conduct inspection activities during off hours. Date: /2-(' 141 Permit Number: [L i ci — Ov 31/ Requested By: HJ bcxce✓l Firm/Company:/ rt.)� Inspection Information ��11 II Project Name: q A -Igo 5 1 C— Project Address/Location: ) %a'2 & ►Ac. 0 Requested Date for Inspection: 2-7-N ✓ Requested Time: 3 AM /® Contact Name: } (ic evi II Phone Number: P--0 (o 77—gt/ya Special Conditions for Consideration: Liee S1t,V'-dowy, ** Contractor will be charged a minimum for three (3) hour inspection time for any off -hours inspection work at $97.50 per hour (minimum total of $292.50). This is to be paid at the time of request. ** The undersigned, as an authorized representative of the above firm, hereby agrees to reimburse the City for its overtime inspections on the above referenced project. A separate invoice will be issued for all inspection time in excess of (3) hours. Signature: Printed Name: WSJ �iJo e^ Date: 02—f y CITY OF 11.90400u4 City Use Only: PERMITCENTER Approved: Disapproved: Paid: Receipt No: Date of Approval/Disapproval: Authorized Reviewer: ..27471// Remarks: H:\Permit Center Forms\Off Hours Inspection.docx PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL14-0034 PROJECT NAME: BOEING #9-120 DATE: 01/14/14 SITE ADDRESS: 9725 EAST MARGINAL WAY S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: () Ot`VI H Building Division IN Public Works Fire Prevention Structural Planning Division Permit Coordinator 1111 PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 01/16/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 02/13/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 FOY INDUSTRIAL ELECTRIC CODA Page 1 of 2 Washington State Department of iLabor & Industries FOY INDUSTRIAL ELECTRIC CORP Owner or tradesperson FOY, DONNY C Principals FOY, DONNY C SHAWN FOY DONNY FOY Doing business as FOY INDUSTRIAL ELECTRIC CORP WA UBI No. 601 930 924 2400 NW 80TH ST STE 118 SEATTLE, WA98117 206-937-6150 KING, County Business type Corporation Governing persons DONNYCHARLESFOY License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. FOYINEC015CH Effective — expiration 02/08/1999 — 02/07/2015 Designated administrator FOY, DONNY C License type Master Electrician Bond CBIC Bond account no. SD8393 Received by L&I 08/03/2001 Insurance No insurance accounts during the previous 6 year period. Savings No savings accounts during the previous 6 year period. ACTIVE License no. FOY**DC977D0 $4,000.00 Effective date 07/10/2001 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601930924&LIC=FOYINEC015CH&SAW= 02/03/2014 FILE fPy64 Permit No. "k1 i% ! • • PIN Wow Tapproval is subject toerrors and onisdons. Appr vi of construction documents does not authorize .:.:. iion of any adopted code or ordnance. Receipt ,proved Feld Copy oondlioneisaciarow1edded th tJ BY BUILDING DIVISION PROJECT SITE 7-127 KING COUNTY AIRPORT OFFICE CENTER (FAA) 99 FROM DOWNTOWN SEATTLE coo 0 EAST MARGINAL WAY CORPORATE PARK FROM SEATTLE—TACOMA AIRPORT 900 TUKWILA FRO KEN & A BURN BOEING DEVELOPMENTAL CENTER EXD 157 RV \\OVA \C 0\ C 20 DEVELOM-\TAB CENT 9725 EAST MARGINAL WAY SOUT TU-<WILA, WAS- NOTO\ 98108 AREA MAP BUILDING ADDRESS: 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 REVISIONS Chan • es shall be made to the scope of work without prior approval of Tukwila Building Division. NO r• Rsvisions will require a new plan submittal ay include additional plan review fees. NO SCALE 9-120 BUILDING LOCATION PROJECT SITE rc 0 NO SCALE \SEPARATE PERMIT REQUIRED FOR: %Mei:hardest a Elechical Plumbing Gas Piping City of Tukwila BUILDING" DML°4SION GENERAL NOTES CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED 8Y CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH WORK WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. I. VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO LEE LEI, 206-304-8415, AT BUILDING 9-51.2 AFTER COMPLETION OF WORK OF THIS CONTRACT. PROJECT CHECKLIST CHECK BOX S THESE DRAWINGS CONFORM TO THE I.B.C., I.F.C., I.M.C., I.P.C., N.E.C. AND THE WAC 51-20 AS ADOPTED OR AMENDED BY LOCAL ORDINANCES AND COMPLIANCE WITH CITY OF TUKWILA, WASHINGTON ZONING. S ROOMS LABELED PER OCCUPANCY PER I.B.C. TABLE 1004.1.2. • BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. Z NUMBER OF PRINTS REQUIRED FOR PERMIT PACKAGE: O 1. TENANT IMPROVEMENT (STRUCTURAL): ❑ 5 SETS OF ARCHITECTURAL DRAWINGS ❑ 5 SETS OF STRUCTURAL DRAWINGS ❑ 5 SETS OF STANDARD DETAILS ❑ 5 SETS OF ENGINEERING CALCULATIONS ❑ 5 SETS OF ENERGY CALCULATIONS ❑ 5 SETS OF CONSTRUCTION SPECIFICATIONS • 2. TENANT IMPROVEMENT (NON—STRUCTURAL): ® 4 SETS OF ARCHITECTURAL DRAWINGS ® 4 SETS OF STANDARD DETAILS ® 4 SETS OF ENERGY CALCULATIONS 13 4 SETS OF CONSTRUCTION SPECIFICATIONS O 3. MECHANICAL, 4 COMPLETE SETS. O 4. FIRE PROTECTION/SPRINKLERS, 3 COMPLETE SETS. S BRIEF PROJECT NARRATIVE: 23, 212 SF OFFICE TENANT IMPROVEMENT PROJECT ON 2ND FLOOR OF EXISTING 9-120 BUILDING IN TUKWILA. WA. NO CHANGE IN USE OR OCCUPANCY. PROJECT INCLUDES ENTRY/ RECEPTION, ENCLOSED OFFICES, MEETING ROOMS, OPEN OFFICE AREA AND A BREAK AREA. THE PROJECT ALSO INCLUDES NEW RESTROOMS AND REPLACEMENT OF 2ND FLOOR EXTERIOR WINDOWS ON WEST AND SOUTH SIDES OF BUILDING. EL DESIGN TEAM OWNER: BOEING DEVELOPMENT CENTER WAY SOUTH • r'*: •: MANN 3®o.I , 1. IEWED PLIANCE NFPA 70 SIC) JAN ti 1 111 /� FOR WITIF - NEC 2014 9725 EAST MARGINAL BOAFIAW ® TUKWILA, WASHING NSTRUCTION 0:LLEOE LEI, lee. IC (206) 304-8.) USER GROUP: USER: COMMERCIAL AIRLINE SERVICES (CAS) PROJECT NAME: AVIATION SERVICES INNOVATION CENTER ( DIRECTOR — MICHAEL SANDIFER ARCHITECTURAL: ZGF ARCHITECTS SEA 4TH AVENUE, SUITE 2400 SEATTLE, WA 98104 (206) 623-9414 CONTACT: GILBERT RECLA, gilbert.reclo@zgf.com STRUCTURAL,MECHANICAL, ELECTRICAL & PLUMBIN RENGNEERS City T• R 4'"dI�ILDJX •%Rvoila I V IISION STRUCTURAL EMERY COFFMAN 1601 5TH AVENUE, SUITE 900 MECHANICAL & PLUMBING: SEATTLE, WA 98101 ELECTRICAL: BEN MAXWELL, (206) 623-0717 MICHEL SOTURA, sot uro0coffman.com maxwell®coffman.com CODE SUMMARY ANALYSIST. OFOENANTOIMPROVEMENT SPEECIFC TOETHISCPROJECTFOR EXITING LAND USE CODE CITY OF TUKWILA, WASHINGTON BUILDING CODES * CITY OF TUKWILA ORDINANCES AND ZONING * 2012 INTERNATIONAL ENERGY * 2012 INTERNATIONAL BUILDING CODE (IBC) CONSERVATION/ WASHINGTON STATE * 2012 INTERNATIONAL FIRE CODE (IFC) ENERGY CODE * 2012 INTERNATIONAL MECHANICAL CODE (IMC) * ACCESSIBLE AND USABLE BUILDINGS * 2012 NATIONAL ELECTRICAL CODE (NEC) AND FACILITEIS WITH STATEWIDE * 2012 INTERNATIONAL PLUMBING CODE (IPC) ADMENDMENTS, ICC/ANSI A117.1-09 OCCUPANCY GROUP GROUP B, OFFICE CONSTRUCTION TYPE TYPE II —A, NON—COMBUSTIBLE EXISTING FLOOR AREAS: BUILDING FOOTPRINT 73,700 S.F. BUILDING GROSS 180,170 S.F. FIRST FLOOR 73,700 S.F. SECOND FLOOR 73,700 S.F. PENTHOUSE 32,770 S.F. AFFECTED AREA TENANT IMPROVEMENT OF APPROXIMATELY 27,633 SQUARE FEET BUILDING HEIGHT 55 FT. STORIES 3 OCCUPANT LOAD: NO CHANGES HANDICAPPED REQUIREMENTS BARRIER FREE FIRE PROTECTION FULLY AUTOMATIC, F/S CLASS 1 SPRINKLERS THROUGHOUT SEISMIC CATEGORY: DESIGN LOADS: ROOF — SNOW 25 PSF ROOF — LIVE 20 PSF FLOOR — OFFICE (LIVE) 150 PSF FLOOR — DEAD 20 PSF (PARTITION) FLOOR — MECHANICAL & STORAGE 125 PSF FLOOR — STAIRS AND CORRIDORS 150 PSF WIND LOADING 80 MPH, EXPOSURE C NUMBER OF EXITS: 4 TOTAL EXIT WIDTH REQUIRED: STAIRS= 148 INCHES DOORS= 111 INCHES EXIT WIDTH PROVIDED: STAIRS= 198 INCHES DOORS= 136 INCHES FIRE EXTINGUISHERS: TYPE: AMEREX MODEL 461, RATED 3A:40B:C, 6 LB CAPACITY. MAXIMUM TRAVEL DISTANCE TO EXTINGUISHER = 75 FEET. MAXIMUM FLOOR AREA PER EXTINGUISHER = 11,250 SF CITY OF TUKWILA BLANKET PERMIT # 13-001-BPA RECEIVED CITY OF TUKWIL JAN 1 4 2014 \t41. 00 3 y PERMIT CENTEi PHASE II CONSTRUCTION Ins A ZGF SYM REVISION e' APPROVED DATE 5YM REVISION 61 APPROVED DATE ORIG 9-120 FCS - SPL LABS 4I6054201-02 DLR CROUP DR/LS 07.12.07 D 9-120 AOE OFFICE MODERNIZATION J9131174-00 ZCF TS 10.1413 ce;i_AnstEirAvc ® ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN ZCF ARCHRECTS DATE 12.12.13 CHECKED TS EN SINELR CHECKED APPROVED APPROVED 12.12.13 SUBTDLE THEE TITLE SHEET CURRENT REV ON 1311 4-00 SYMBOL G DATE 12.12.13 SHEET GO 9-120 FCS - SPL LABS DCNJOT JJI6054201-D2 DLR GROUP LS/DR 07.25.07 -120 ASIC - 60% SUBMITTAL ISSUE 4131174-00 ZGF TS 1 0.31.13 RECORD DRAWING JJ 16054201-02 DLR GROUP LS 04.11.06 9-120 ASIC - 90% CO REVIEW JJ131174-00 ZGF TS 11.21.13 9-120 ASIC - EXTERIOR ENVELOPE OCT TS 10.01.13 G 9-120 ASIC - 100% CD ISSUE J#131174-00 OCT TS 12.12.13 9-120 ASIC - 60% SUBMITTAL ISSUE ZGF TS 10.04.13 APPROVED BY DEPT. DATE ARCHITECTURAL MASTER BUILDING 9-120 COL. DEV. CENTER. WA JOB NO. 131174-00 COMP NO. DWG NO. 09-120—GO POWER PLAN SYMBOLS LIGHTING GENERAL DEMOLITION NOTES GENERAL CONSTRUCTION NOTES ® PANELBOARD, 480Y/277V, 3 PHASE • PANELBOARD, 208Y/120V, 3 PHASE EQUIPMENT IDENTIFICATION "X" DENOTES EQUIPMENT NUMBER "Y" DENOTES HP OR KW RATING E ENCLOSED CIRCUIT BREAKER 0' DISCONNECT SWITCH, NON -FUSIBLE m' DISCONNECT SWITCH, FUSIBLE - MOTOR STARTER (COMBINATION) OR A TRANSFORMER (SIZE AS SHOWN, IN KVA) O OR C] JUNCTION BOX 4 460 VOLT MOTOR (SIZE AS NOTED) 4 115 VOLT MOTOR (SIZE AS NOTED) O TELEPHONE/POWER POLE 20A, 120V, I PHASE, DUPLEX, HUBBELL 5262 (2) 20 DUPLEX RECEPTACLES, HUBBELL 5262 CONDUIT NOT BURIED BURIED CONDUIT WIRING (UNDERGROUND & IN FLOOR SLAB) CONDUIT, UNDER RAISED FLOOR -/"\_/ FLEXIBLE METAL CONDUIT INDICATES PHASE CONDUCTOR (SIZE AS NOTED) INDICATES NEUTRAL CONDUCTOR 7/ \V INDICATES GROUND CONDUCTOR INDICATES ISOLATED GREEN GROUND CONDUCTOR CIRCUIT SOURCE PANEL/(2P OR 3P CKT), IP CKT \- ID6-1/(1,3,5),7 CONDUIT TURNS DOWN 0 CONDUIT TURNS UP CONDUIT ONLY D —E— EMERGENCY CIRCUIT COMMUNICATIONS Z TELEPHONE OUTLET - ROUGH -IN ONLY. SINGLE GANG J-BOX WITH I" C. TO ACCESSIBLE CEILING SPACE DATA OUTLET - ROUGH -IN ONLY. SINGLE GANG J-BOX WITH IY4" C CEILING SPACE Y VOICE/DATA OUTLET GROUNDING PROVIDE TO ACCESSIBLE 00 1' X 4' SURFACE FLUORESCENT LUMINAIRE CLASS 1, DIV 1, EXPLOSION PROOF, COPPER FREE ALUMINUM HOUSING, STAINLESS STEEL HARDWARE, HIGH IMPACT RESISTANT TEMPERED BOROSILLICATE GLASS GLOBES, ADJUSTABLE ALUMINUM SURFACE MOUNTING BRACKETS. 4' STRIP FLUORESCENT LUMINAIRE, COLD ROLLED STEEL HOUSING, BAKED WHITE ENAMEL FINISH, WIRE GUARDS FULL -CUTOFF WALL MOUNTED LUMINAIRE, DIE-CAST ALUMINUM HOUSING, WET LOCATION LISTED, PREMIUM POLYESTER POWDER COAT PAINT FINISH IN BRONZE LIGHT FIXTURE - FLUORESCENT WITH ALL BALLASTS ON EMERGENCY CIRCUIT Q- SELF CONTAINED, WALL MOUNTED EMERGENCY LIGHTING UNIT EXIT SIGN, WALL MOUNTED EXIT SIGN, CEILING MOUNTED FIXTURE IDENTIFICATION "X" DENOTES FIXTURE TYPE "ZZ" DENOTES FIXTURE WATTAGE Oi $,$3,$4 $LV, 2$L3/ , 4$Lv —LV--- GROUND CABLE (UNDERGROUND) & CABLE CONNECTION GROUND ROD CONNECTION 6 GROUND CABLE PIGTAIL —6— GROUND CONDUCTOR IN CONDUIT SUM FIRE ALARM MANUAL PULL STATION Ors FIRE SPRINKLER TAMPER SWITCH O FIRE SPRINKLER FLOW SWITCH [� FIRE SPRINKLER PRESSURE SWITCH REVISION APPROVED TOGGLE SWITCHES - LINE VOLTAGE, SINGLE POLE/ 3-WAY/ 4-WAY NUMBER OF SWITCHES UNDER COMMON PLATE AS INDICATED. LOW -VOLTAGE LIGHTING CONTROL SWITCHES. NUMBER OF SWITCHES UNDER COMMON PLATE AS INDICATED. LOW -VOLTAGE LIGHTING CONTROL WIRING. 3/C #18 AWG IN I/2"C UNLESS OTHERWISE NOTED. DIAGRAM SYMBOLS SINGLE LINE 1// / ID10-I 600 A M.L.O. 3 PH, 3 W DATE TRANSFORMER (DASHED LINE INDICATES ELECTROSTATIC SHIELD) FUSED SWITCH DISCONNECT SWITCH ID10-2 225 A M. BKR, 3 PH, 4 W 2 480:120 3 SAM 800:5 PANELBOARDS DISCONNECT SWITCH POTENTIAL TRANSFORMER QUANTITY & RATIO AS SHOWN CURRENT TRANSFORMER QUANTITY & RATIO AS SHOWN INTERLOCK K=KEY M=MECHANICAL E=ELECTRICAL AMMETER w/SWITCH VOLTMETER w/SWITCH WATTHOUR METER REVISION BA 1. CONDUIT AND WIRING SCHEDULED FOR DEMOLITION SHALL BE COMPLETELY STRIPPED AND REMOVED BACK TO THE SOURCE OR NEAREST ACCESSIBLE JUNCTION BOX. SCHEDULED TO REMAIN CONDUIT STUB UPS SHALL BE CUT OFF AND PLUGGED FLUSH WITH SLAB SURFACE, UON. 2. COORDINATE DISPOSITION OF REMOVED MATERIALS AND EQUIPMENT WITH THE BOEING REPRESENTATIVE. COPPER AND OTHER METALS SHALL BE SALVAGED TO BOEING. PLACE MATERIALS IN CONTAINERS PROVIDED BY BOEING. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DE -ENERGIZING ANY CIRCUITS OR EQUIPMENT REQUIRED FOR THIS DEMOLITION WORK. 4. COORDINATE AND SCHEDULE WITH THE BOEING CONSTRUCTION MANAGER ANY POWER, TELEPHONE, DATA, CMCS, PLANT PAGING, FIRE ALARM AND ADT CONTROLS SHUT DOWNS REQUIRED BY THIS DEMOLITION WORK AND, ALSO ENSURE THAT ADEQUATE TEMPORARY AND/OR REROUTING OF SERVICES ARE APPROVED TO AREAS NOT PART OF THIS DEMOLITION WORK, BUT WHICH ARE ADJACENT TO THE AREA(S) OF WORK AND WHICH WOULD BE AFFECTED BY A SHUT DOWN. THE CONTRACTOR SHALL FOLLOW THE BOEING STANDARD LOCKOUT/TAG OUT PROCEDURES THROUGHOUT ANY REQUIRED SHUT DOWN, DEMOLITION AND/OR TEMPORARY RECONNECTION PROCESS. 5. REMOVAL AND DISPOSAL OF ALL IDENTIFIED HAZARDOUS MATERIALS SHALL BE PERFORMED UNDER THE REQUIREMENTS OF BOEING SHEA, OSHA, EPA AND ANY OTHER AUTHORITY HAVING JURISDICTION IN APPLICABLE STATE, CITY AND LOCAL CODES. ABBREVIATIONS AFT AHC AL ATS AWG CB C.O. CRU DED DP EF EMT EPO EWC FACP FAR FATU FVNR GFI GND,G HP IMC LV M. BKR. MCC MLO NACB N.C. N.O. PH PNL PVC RF RMC RVNR SRP SRR SWBD SF ST THHN THWN UH WP XFMR APPROVED ABOVE FINISHED FLOOR ABOVE HUNG CEILING ALUMINUM AUTOMATIC TRANSFER SWITCH AMERICAN WIRE GAUGE CIRCUIT BREAKER CONDUIT ONLY COMPUTER ROOM UNIT DEDICATED DISTRIBUTION PANEL BOARD EXHAUST FAN ELECTRICAL METALLIC TUBING EMERGENCY POWER OFF ELECTRIC WATER COOLER FIRE ALARM CONTROL PANEL FIRE ALARM RELAY FAN TERMINAL UNIT FULL VOLTAGE, NON -REVERSING GROUND FAULT INTERRUPTER GROUND HORSEPOWER INTERMEDIATE METAL CONDUIT LOW VOLTAGE MAIN BREAKER MOTOR CONTROL CENTER MAIN LUGS ONLY NON -AUTOMATIC CIRCUIT BREAKER NORMALLY CLOSED NORMALLY OPEN PHASE PANEL POLY -VINYL CHLORIDE (CONDUIT) RETURN FAN REGID METALLIC CONDUIT REDUCED VOLTAGE, NON -REVERSING SMOKE REMOVAL PANEL SMOKE REMOVAL RELAY SWITCHBOARD SUPPLY FAN SHUNT TRIP CIRCUIT BREAKER HEAT -RESISTANT THERMOPLASTIC (WIRE INSULATION TYPE) MOISTURE- AND HEAT -RESISTANT THERMOPLASTIC (WIRE INSULATION TYPE) UNIT HEATER WEATHER PROTECTED TRANSFORMER DATE ORIG BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-00 BRM CEI 12.12.13 sitfirte7.k=irAvc. AL A. WORK INCLUDED: FURNISH LABOR, MATERIALS, EQUIPMENT AND TOOLS FOR COMPLETION OF ELECTRICAL SYSTEMS AND RELATED WORK AS INDICATED ON THE DRAWINGS. B. CODES AND ORDINANCES: WORK SHALL COMPLY WITH LOCAL ORDINANCES, AND SHALL CONFORM TO THE NEC. C. RECORD DRAWINGS: MAINTAIN UP TO DATE "AS -BUILT" DRAWINGS ON SITE AT ALL TIMES. CLEARLY INDICATE ON THESE DRAWINGS, IN RED PENCIL, THE LOCATIONS OF CONCEALED AND UNDERGROUND CONDUIT, AND DEVIATIONS TO THE CONTRACT DRAWINGS. D. WIRING DEVICES: SPECIFICATION GRADE AND UL-LISTED, BROWN COLOR WITH GALVANIZED DEVICE PLATES. E. CIRCUIT BREAKERS INSTALLED IN EXISTING PANEL BOARDS: THE SAME MANUFACTURER AND FRAME TYPE AS THOSE REQUIRED FOR THE EXISTING PANELBOARDS. RATINGS AND FRAME TYPES SHALL BE AS INDICATED ON DRAWING OR IN PANEL SCHEDULES. F. SUPPORTING DEVICES 1. FASTEN HANGER RODS. CONDUIT CLAMPS, AND OUTLET AND JUNCTION BOXES TO BUILDING STRUCTURE USING BEAM CLAMPS. 2. USE SELF -DRILLING ANCHORS OR EXPANSION ANCHORS ON CONCRETE SURFACES; SHEET METAL SCREWS IN SHEET METAL STUDS. 3. DO NOT FASTEN SUPPORTS TO PIPING, DUCTWORK, MECHANICAL EQUIPMENT, OR CONDUIT. 4. FABRICATE SUPPORTS FROM STRUCTURAL STEEL OR STEEL CHANNEL, RIGIDLY WELDED OR BOLTED TO PRESENT A NEAT APPEARANCE. USE HEXAGON HEAD BOLTS WITH SPRING LOCK WASHERS UNDER ALL NUTS. COLD GALVANIZE ENDS OF CUT CHANNEL IN EXTERIOR AND DAMP LOCATIONS. 5. INSTALL SURFACE MOUNTED CABINETS, ENCLOSURES, AND PANELS WITH A MINIMUM OF FOUR ANCHORS. PROVIDE STEEL CHANNEL SUPPORTS AND PROVIDE MINIMUM 1" GAP BETWEEN WALL AND EQUIPMENT. G. DEVICE MOUNTING HEIGHTS AND ORIENTATION 1. FACTORY AREAS: MOUNT DEVICES AT +48" ABOVE FINISHED FLOOR UNLESS OTHERWISE NOTED. IF IMMEDIATE AREA HAS DEVICES MOUNTED BELOW 48", CONTACT OWNER FOR RESOLUTION OF MOUNTING HEIGHT. 2. OFFICE AREAS: MOUNT DEVICES AT +18" ABOVE FINISHED FLOOR UNLESS OTHERWISE NOTED. IF IMMEDIATE AREA HAS DEVICES MOUNTED BELOW 18", CONTACT OWNER FOR RESOLUTION OF MOUNTING HEIGHT. 3. SWITCHES SHALL BE MOUNTED WITH OFF POSITION DOWN. 4. 120V STRAIGHT BLADE RECEPTACLES SHALL BE MOUNTED WITH GROUND BLADE AT BOTTOM. ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED DV DEPT. DATE DRAWN R. FROCCE R.NELKEU B. MAXWELL DATE 12.12.13 12.12.13 H. CIRCUIT IDENTIFICATION 1. PROVIDE SELF-ADHESIVE LABELS ON INTERIOR 120V RECEPTACLES, 120V & 277V LIGHT SWITCHES, DEVICES, BOXES AND JUNCTION BOXES, 480V RECEPTACLES, AND DISCONNECT SWITCHES. LABELS SHALL BE 3/8 INCH. BLACK LETTERS ON WHITE BACKGROUND. 2. PROVIDE NAMEPLATES ON ALL PANEL BOARDS, CONTROL PANELS, ETC., AND ALL EXTERIOR EQUIPMENT AND DEVICES, INSTALLED OR REVISED UNDER THIS CONTRACT. THIS INCLUDES THOSE NOT PHYSICALLY RELOCATED BUT RECIRCUITED. SECURE NAMEPLATES TO EQUIPMENT USING SCREWS OR WIRE LOOP. ADHESIVES ARE NOT ACCEPTABLE, USE ENGRAVED NAMEPLATES, 1" HIGH WHITE LAMINATED PLASTIC WITH Y" HIGH ENGRAVED BLACK LETTERS. 3. PROVIDE WIRE AND CABLE MARKERS ON EACH CONDUCTOR IN PANEL BOARD GUTTERS, PULL BOXES, OUTLET AND JUNCTION BOXES, AND AT ALL LOAD CONNECTIONS. IDENTIFY WITH BRANCH CIRCUIT OR FEEDER NUMBER AS INDICATED ON DRAWINGS. FOR CONTROL WIRING, IDENTIFY WITH WIRE NUMBER INDICATED ON THE SCHEMATIC OR INTERCONNECTION DIAGRAMS. USE CLOTH MARKERS, SPLIT SLEEVE OR TUBING TYPE 4. NAMEPLATES AND LABELS SHALL INDICATE PANEL AND CIRCUIT NUMBER EQUIPMENT IS SERVED FROM, (E.G. - "1G8/2abc" FOR CIRCUIT 2obc FROM PANEL 108) I. EXTERNAL STEEL 1. EXTERIOR GALVANIZED MATERIALS ARE NOT ALLOWED. REFER TO SPECIFICATION 260500. J. ALL NEW WIRING SHALL BE R12 THHN/THWN UNLESS OTHERWISE NOTED. REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JAN 3 1 2014 City of -Tukwila BUILDING DIVISION 9-120 ASIC 100% CD ISSUE RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER .COFFMAN SUBTITLE LEGEND, ABBREVIATIONS & NOTES NGINEERS 1601 F10n Avenue, Sulte 900 I Seattle, WABB101 Pn 206.62 .0111 i 1.. 706.624.3716 w1m,.,..e,n LASTING mum, l Neted CURRENT REVISION 131174-00 5'BOLORIG DATE 12.12.13 GINEER B. MAXWELL CHECKED APPROVED APPROVED 12.12.13 TITLE BOEING 9-120 ASIC OFFICE MODERNIZATION BUILDING 9-120 ELECTRICAL MASTER DEV. CENTER, WA SHEET E1 E* JOB MO. 131174-00 COMP NO. DWG No. 9-120-E LEGEND -far -- SPA REVISION -C 1S1 FLOOR -C. 394/0 & 192 C EPR FDR Alf- AN-IRA-TST-PL I APPROVED DATE 3C44/0 ARMORED CABLE IN TRAY W/ H0 BARE GRIND FDR-4 OVERHEAD OF 1st FLIT S'M 4'C FROM 2ND FLOOR DN OUTSIDE OF WALL (FDR-4) 4-C TO VAULT #6 (FOR 7) REVISION SUB 1175 MOE _— I L---J 4'C 314/0 EPR FDR-4 (SUB #11 2-4'C TO VAUL #B (I IN USE; FDR 3) I I II -r -T 111 11 1 2-4'C TO SUB 134 (1 IN USE; FDR-3) BR APPROVED DATE A BOEING 9-120 ASIC OFFICE MODERNICATION 13174-DO BRM CEI 12.12.13 4-4"C 10 VAULT 93 (2 IN SE; FOR-1 & FDR-4) ev 4-4-C TO VAULT 95 (2 IN USE; FDR-3 & FOR-7) 13.8kV FEEDER PLAN SCALE: 1/16"=1'—O" (:) e___AsrgrEzAf.c. 0 a a ACCEPTABILITY THIS DESIGN AND/DR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE RREIE ,EIEvo,s. ,r u= f1CGM'AEI[ DRAWN D. OTTEN CHECKED UNIT SUBSTATION PAD — TYPICAL PW ECR 0011S II a 14 sNLLI H lT-O'IOBO M35 NI REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JAN 31 2014 City of Tukwila BUILDING DIVISION_ HATE 09.04.13 0 GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES PROVIDE PENETRATION IN EXTERIOR WALL IN THE 1ST FLOOR CEILING SPACE. SEAL PENETRATION ONCE CONDUIT HAS BEEN INSTALLED. PROVIDE NEW MEDIUM VOLTAGE CABLES AND CONDUIT BETWEEN SUB 11 AND SUB 35. INTERCEPT EXISTING CONDUR AND EXTEND TO TERMINAL BOBEHIND SUB 35. CONDUIT 10 BE ROUTED TIGHT TO UNDERSIDE OF 2ND FLOOR SLAB. COORDINATE EXACT ROUTING WITH EXISTING DUCTWORK, PIPING MD OTHER EOUIPMENT IN THE CEILING SPACE. PROVIDECESS. 60'x60'oB'D PULL BOX. COORDINATE EXACT LOCATION WITH EXISTING CONDITIONS 10 ACCOMMODATE AC PROVIDE NEW CONDUIT WITH MEDIUM VOLTAGE CABLING SHOWN. CABLE TO BE SHIELDED, 15kV. MV-I05 WITH A 133% INSULATION LEVEL. PROVIDE EQUIPMENT GROUND CONDUCTOR SIZED 10 MATCH EXISTING. OKONITE / 115-23-3121 OR APPROVED EQUAL. PROVIDE 3M 0-1-III COLD SHRINK TERMINATION AT FOR EACH MEDIUM VOLTAGE CABLE AT TERMINATKIN POINT. CABLE SHIELD TO BE GROUNDED 10 EOUIPMENT GROUND BAR Al BOTH ENDS. ® PROVIDE NEW MEDIUM VOLTAGE CABLES AND CONDOR BETWEEN SUB 35 AND SUB 75. INTERCEPT EXISTING CONDOR COMING FROM TERMINAL BOX BEHIND SUB 35 AND EXTEND TO SUB 71. COORDINATENSTALLATION. CONDUIT ROUTING AND ACCESS TIMES THROUGH THIS SPACE WITH THE USER PRIOR TO I CAREFULLY COORDINATE MEDIUM VOLTAGE FEEDERS ROUTED DOWN THIS CORRIDOR WITH EXISTING BUSDUCT SO ACCESS TO BUSDUCT IS NO1 BLOCKED. ROUTE CONDUIT ON THE EXTERIOR OF THE EXISTING BUILDING PARALLEL TO OTHER CONDUITS, 9-120 ASIC 100% CD ISSUE SUBTITLE 13.8KV FEEDERS RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER ACOFFMAN NGINEERS 1601 Fhih Avenue, Suite BOO I Seattle, W A86101 Ph 204.423A717 11n]04.014]TTS raMnnram CURRENT REVISION 131174-00 �"NOL A DATE 12.12.13 NTINI EH CHECKED APPROVED APPROVED TITLE BOEING 9-120 ASIC OFFICE MODERNIZATION ELECTRICAL MASTER BUILDING 9-120 SHEET E2A E* JOB NO. COMP NO. 9-120—E2A mr ripe I, /INT SIM REVISION BY APPROVED DATE son EXIST. NW CORRIDOR 109 XH3/1a,10 (OLD 8N) REVISION Stairwell #1 - Northwest A SCALE: 1/4°=1' Br APPROVED 041E A REPLACE STAIRWELL LIGHTS 57791400 ESBRODK 02.26.06 B BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-00 BRM CEI 12.12.13 1E10 1E547 �BOE/A/6 LEVEL 2A 0 LEVEL 3A / \ REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JAN 31 2014 City of Tukwila BUILDING DIVISION REMOVAL MAR ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN DATE CHECKED I J 1 XH3/6 @ Column C-3 O CONSTRUCTION NOTES I> DEMOLISH EXISTING LIGHT FIXTURE AND ASSOCIATED WIRING AND CONDUIT. WIRING AND CONDUIT SERVING OTHER FIXTURES NOT BEING REMOVED TO REMAIN. EXISTING J-BOX AND ASSOCIATED WIRING TO REMAIN. EXISTING EXIT SIGN TO REMAIN. 9-120 ASIC 100% CD ISSUE SUBTRLE -StairwaysN01 NW RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER OFFNIAN NGINEERS 1eo1 PUS Avenue, Bulb ODD I Seattle, WA B8101 Pe MA:M.0M fax 200.02107n c ne LASTING m.,nla.au.w. CURRENT REVISION 131174-00 SYMBOL B DATE 12.12.13 TNDINEER CHECKED APPROVED APPROVED TnLE BOEING 9-120 ASIC OFFICE MODERNIZATION BUILDING 09-120 (DISCIPLINE) MASTER COL. X-X/X-X SITE STOAT 1E547R E* JOB NO. COMP NO. OWE NO. 09-120-1E547R SHIELD ROOM LIE LEGEND: ICC-8 ,ODOR C. 0R06FER 90 Al 51A RVAV No. B Al COL. E/1 BLOC. 9-101.I CED 10 FIEL• VERILY UK. POAER 044 OLD AL (00 BERG. POWER RUNNIER BW11O1 ELERC. P9AER PAL. 1OE1 I STAIRW.IV A COL . El. 9-WI LTD x} IX0n I100 C CL AN -I 25 // AK-I-25 250AT \ 300AT Y1 Y2 I100/70A 400A1 Y3 CALLE DO OW me 0PN or C ]OnY. • 0* 0 43WA *A 5N0A/laO v xOeV/lm 'S 10 30NV4 20. 2 ( 100 0 206V- 480V (So NJ-1-I 0 120/200V- 480V- 4e0 240/GLOP C co ISVVA 120/24WV- M 499 1—T r r BUS DUCT /1, 400A, 480/277V. 3PH• 3W - COL. H/3-7 MEZZANINE IM'S /120V 100A W H- J/4-5 LLOS ICAO I Ic'V/240V- 1 W TVs c, 4/0/1/ ev- ILJ148J m BLDC, 9-65 A AK-I-25 AK I-25 SPACE 300A1 Y4 YF5 INSTRUMENT IIF2 250A AK-1-25 IIF6 300A Ak--256001425 TIE IIF10 (44F2) 3WA AN-I-25 I IF14 (44F6) 400A AN-1-25 Sub 35 IIF3 IIF7 IIFII (44F7) 11E15 (44F3) MAIN 400A 300A TIE SPACE 300A 1600A AK-I-25 AK-I-25 ,4, 1600A Alb-1 26 Ak-I-OS AN-1-50 AA-I-50 1174 11E8 11E12 (44E2) 11716 (4474) Sub II of Sub 39 SPACE AN-I-25 SPACE AA-I-25 500A Al-1-25 SPACE AN -I -OS IIFI TIE 0 "504 11E5 1179 1600A IIFI) (44F9) 11E12 (4415) Alt -I -OS AR -I -ES 300A SPACE 600A SPACE Ak-I-25 AK-1-25 F10-17 & Sub 3: AN-I-25 AX-I OS SUBSTATION No. II 44, T ( Ak-I-25 300AT SPACE Y6 u L---L,bo ,SNVA J8 I] 420/208V- 80 J6 C. 3/4/0 n ( AK -I -ES 300A1 YF7 600A, 4 POLE B S DUCT TIE CKT SEE SHEET E4534 TO S.S. (35 A n 11H CC-9 cIX SCA = 18,500A n ( AK-1-50 1600AT SUBSTATION No. II V CAK_i 25 600AT 227 OLD IOU ( ISO ai rL AK -I E5 AK-I-25 AK-I-25 ( A -I-25 / AN-I-25 SPACE SPACE 1600AT ` 1600A1 6 300AT ‘....A.L1000KVA (7=563%) J,BKV LINE ffI FROM EAST MAIN SUBSTATION 86 BLOC. 9-60 COL E/5 TO PANEL 6P/(4.0 W W0 B100. SPARE Af 3 2001I50155 0 m Ill1 TER IL R AK- I - S PX -I -OS (/Ak-I-25 SPACE ` 500A1 600A1 \/ \ SPACE SPACE 0/2 Y8 Y9 Y Y YD YII Y12 Y13 Y4 TIE 'B' 11E•A' oww 44F2 8044F7 IXD 44re 0.044r9 OLD441-6 OLD 44Ft ro COMP. RM. D3-I n COP. PM OR 205. be x 1 15kVA 4sAVa •4AAAF AT- 306v/1041,1 44 IFW D 120/20. 480V H6 OLC1 P. N00A, I60/21N,3PN,SN COL. E/3-9 00 rost HEW ,20/208V- ew E1 u C (00 OLD 140/106V CLOT DES/YS 308 COL F/6 m m' C� k-I-25 Ak-I-OS SOOA7 SPACE u 30AvA 1501AT. IOU aI20/10aV- ( 4. C 08 AK-I-25 SPACE Y15 1716 YFI7 010 4413 00 4414 510 44rs SECOND FLOOR FIRST FLOOR GENERAL NOTES: 1.) ALL CONDUIT TO BE 1/2" EMT UNLESS OTHERWISE NOTED. 2.) ALL WIRE TO BE g12 1HWN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWNC COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS BOO VOLTS OR LESS. 120/208V 277/480V 'A" PHASE (LEFT BUS IN PANEL) BLACK BROWN PHASE (CENTER BUS IN PANEL) RED ORANGE 'C- PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY ECUIPMENT GROUND GREEN 4.) LARGE SIZE CONDUCTORS WHICH D0 NO1 HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) ALL UNUSED CONDUIT AND WE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSY/AY. 6.) FEEDERS 10 PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3 7.) DYMO LABEL ALL RECEPTACLES. JUNCTION BOXES. SNATCHES, ETC.. WITH CIRCUIT IDENTIFICATION. 8.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. REFERENCE DWGS. SEE DWG. 09-120-E5 2>SEE DWG. 09-YD-E4A CONSTRUCTION NOTES: REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JAN 31 2014 City of Tukwila BUILDING DIVISION_ FOR REFERENCE ONLY FACILITY DESIGN BY DATE RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER ACOFFMAN NSINEEKS 1001 PION Avenue, Suite 0001 Seattle, WA 90001 PA 24(1230717102o 2O6.004.5775 LASTING ,w.wl,..1w..« SYM REVISION BY APPROVED DATE REVISION BY APPROVED DATE AS -BUILT ERICKSON O6/01/95 c____AroweAfc. ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN D.R. CHESTERFIELD CHECKED DAYE 7/18/94 SUBTITLE ONE LINE DIAGRAM SUBSTATION 11 CUR ENT REVISION 131174-00 SYMBOL A DATE 12.12.13 ENOINETA R. ERICKSON SHEET E4S11 E* CHANGE BOARDER AISAKA 9-9-08 A BOEING 9-720 ASIC OFFICE MODERNIZATION 131174-D0 BRM CEI 12.12.13 APPROVED BY DEPT. DATE CHECKED 11/14/94 APPROVED J. VAVREK APPROVED N. MD -TA 11/14/94 11/14/94 TITLE BOEING 9-120 ASIC OFFICE MODERNIZATION BUILDING 9-120 ELECTRICAL MASTER DEV. CENTER, WA JOB NO. COMP NO. 9-120-E4S11 > I-I/4"-3g4 6 IgRG 480Y/2774 12C>I-I/4"-4g4 & Ig8C -• IIZ>•I-I/4''-4g4 & IOC TO TO 3B-8 3C-I �,E CIE UCT #4, 480/277V, 3PH, 4W 9,547A I-1/4'-3g2 & 1/80 1 SQUARE ION METER 2A7-2 225A 100A NCB 3PH 3W /2'-(I)g18AWG TSP-46' 32DAT IFI sv 2A7-1 800A NCB 3PH 3W I/2 (I)gIBAWG 1SP 75KVA 480- 2087/120V IT I/4"-314 & I18G 2A7-3 2A7-4 225A 225A 225A MEG 100A MCB 3PH 4W 3PH 4W ( YP) I.---L '—'l =y- (3)2-I/2•-3g30DKCMIL 8 Ig1/0G Q 2-1/2' 41f /0 8 112G J I-I/4'-3g2 & IgAC /2°-(1)1IBAWG TSP - I-I/4'-3g2 8 Ig8C .I-I/4'-4g2 d IfOG A 9-120 RENOVATION RECORD DRAWING AK-I-25 800AT REVISION OLO IL D INSTALL POWER METER FEEDER SUB36-F4 COMBINED DLR D G E4A WITH OLD E4A 45KVA 480- 80Y/277V 22250 225A NCB 3PH 4WW 3PH BUS DUCT No. 3, 400A, 480V, 3PH ( AK-I-25 400AT Yr3 Jg16054201-02 Jg16054201-02 57671601 BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-D0 BY COFFMAN ES BROOK S.RUDELL BR APPROVED E. SWEET E. SWEET VAVREK AVREK CEI 30KVA 30KVA T II 0/208V a 120/208V 11 NORTH. EC I,4°-3g2 & If0G I-1/4-4g2I18 I/8G COL. B-C/2-9 ( 00 30-2 OUTDOOR OUTDOOR I/2°-(I)1118AWG TSP I I 75KVA© 2A1-6 480- 225A 100A MCB 3PH 4W 8 T 800 AF v DATE 07.12.07 05.15.08 05.22.08 07.25.0E 12.12.13 208Y/120V COL. C/I TD C/8 282-2 225A 225A MCB 3PH 4W 182-} 225A 100A MCB 3PH OW 2-I/2"- g4/0 8 Ig2G OLD 51 OLD 2IP SUBSTATION No. 35 COL. A/6 45KVA 480- I20/208V g s ( AK-I-25 400AT vV IF4 ( 16001 AK-1-50 V 282-4 225A 10DA MCB 3PH 4W ISO. GND. 2 5A 100A MCB 3PH 4W 2B2-I 225A 50A NCB 3PH 4W 225 3B-6 45KVA 1 140- 120/208V 3B-8.1 DATA CLOSET 31A6 FED FROM PNL 2F2-3 LOP 2BL-I BUS DUCT, COL. 8/2, 600A, 480V, 3PH, 3W 48O/277V I000KVA (Z=5.55%) 13.8KV LINE #1 FROM EAST MAIN SUBSTATION REVISION BY AP (KO (AV_I_25 400AT YF5 1%-(2)2V V N EEIG SPARE n (SPACE YF8 BUS DUCT COL C/I-7. 600A. 3PH, 4W 3Pj0N PNL. 3A6 F7 112.51(VA 4B0- 120/208V 2' C., 314/0 8 I14/0 G —' 6"x8"748" WIREWAY 200 J 3D/20 15KVA 0/208V PNL. 3H-7 B6-1 225A 150A MB 3PH 4W 208Y/120 V ( AK-I-25 600AT vV I F6 9-120 ASIC 100% CD ISSUE DALE g)i___AgursEzAwe 60/40 308VA n480- 120/208V r I • 45KVA _ J 100/80 30/20 D6 2 5A 150A NB 3PH OW 208Y/120 V I"C-(3)ft4 I"C-(3) 4 BUS DUCT TIE CIRCUIT TO SUB. STA No. II n ( AK-I-25 600AT ffOFFMAN N GIN E E R S 1601 FITS Avenue, 6ulie 9001 50MA, WA 68101 PA 200020A717110a 200.024.770 ommancom LASTING ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. TE --I200/200 0,' C „ 3g4/0 8 44/0 G S b NDITIONER 10RVA T 120/ 120 .I PNL. 3J6 2 FILTER 200Ar4 PNL. 3J-6 T PAL. 3J6.1 75KVA 480- 120/208V J 60/40 ANECHOIC CHAMBER ON ROOF THIRD FLOOR REVIEWNC1�+►k' COMPEL NFPA 70 - NEC JAN 31 2014 OR City of Tukwila DIVISION SEE SHEET E4S11 INSTRUMENTATION 35F1 35F5 35F2 35E6 MAIN 35E3 35511 CIT TIE 35E4 35F8 DRAWN COFFMAN cHECkED E. SWEET ONLale CHECIKED APPROVED JOHN J. VAVREK APPROVED RECEIVED Y OF TUKWIL JAN 1 4 2014 SUBSTATION ND. 35PERMIT CENTER COI. 4/6-1, BLOC. 9-120.I ALL ELECTRICAL EQUIPMENT. FEEDERS AND DEVICES SHOWN IN THIS ROOM ARE NEW. I> PROVIDE A #2 GROUNDING ELECTRODE CONDUCTOR FROM TRANSFORMER TO BUILDING GROUND SYSTEM. PROVIDE ARC FLASH AND COORDINATION STUDIES PER SPECIFICATION SECTION 260573 FOR ALL NEW EQUIPMENT INSTALLED OR EXISTING EQUIPMENT MODIFIED UNDER THIS PROJECT. I> FAULT CURRENT DOWN STREAM OF TRANSFORMER LESS THAN 10,000A ATE 05.23.07 05.23.07 07.16.07 UBTITLE TITLE ONE LINE DIAGRAM SUBSTATION 35 ,. LEGEND A LAAlI DRAW OUT AIR CKT. BRK. FUSED SWITCH 1000kVA TRANSFORMER 4".7R 13,8kV, 480/27N, 36 n • 208Y/120V PANEL 480Y/277V PANEL AUTOMATIC TRANSFER SWITCH BATTERY L a 11 TRANSFORMER /T r1_ 480V:208Y/120V, 3A I XXXXX> FAULT CURRENT GENERAL NOTES 1.) ALL CONDUIT TO BE I/2" EMT UNLESS OTHERWISE NOTED. 2.) ALL WIRE TO BE g12 THWN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR COOING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 60D VOLTS OR LESS. 120/208V 277/480V 'A" PHASE (LEFT BUS IN PANEL) BLACK BROWN 'B PHASE (CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4.) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK 10 SOURCE. INCLUDING PLUG-IN CIRCUS BREAKERS ON BUSWAY. 6.) DYMO LABEL ALL RECEPTACLES. JUNCTION BOXES. SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 7.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF 8 ) SOUARE D ENHANCED ENERCEPT METER CONSTRUCTION NOTES PROVIDE NEW 34-3W BUS PLUG. MANUFACTURER MAKE, MODEL AND PLC RATING TO MATCH EXISTING BUS PLUGS ON THE BUS DUCT. PROVIDE NEW FEEDER. PROVIDE NEW 480V PRIMARY 480Y/27N SECONDARY TRANSFORMER TO SERVE THE EXISTING LIGHTING PANEL. MOUNT TO SUIT FIELD CONDITIONS. U.O.N. ® REPLACE EXISTING MAIN BREAKER WITH NEW 100A MAIN BREAKER IN PANEL BOARD. AIC RATING TO MATCH EXISTING. 123%- BOEING 9-120 ASIC OFFICE MODERNIZATION ELECTRICAL MASTER BUILDING 9-120 Ro oN EAE BREAKER SETTING TO 1.OIn FLOOR MOUNT NEW TRANSFORMER NEXT TO EXISTING PANEL. COORDINATE EXACT LOCATION WITH EXISTING CONDITIONS. PROVIDE A #8 GROUNDING ELECTRODE CONDUCTOR FROM TRANSFORMER BUILDING GROUNDING LOOP. REPLACE SUBFEED BREAKER SERVING PANEL E6 WITH NEW 100A BREAKER. AIC RATING TO MATCH EXISTING. PROVIDE NEW 800A TRIP UNIT IN EXISTING SUBSTATION BREAKER. ABB PART NUMBER DEO800RP. PROVIDE NEW 70A MAIN CIRCUIT BREAKER PROVIDE NEW 800A DISTRIBUTION BOARD FULLY RATED FOR 35KAIC TO SERVE LEVEL 2 LOADS. REFER TO PANEL SCHEDULE FOR ADDITIONAL INFORMATION. COORDINATE EXACT TRANSFORMER LOCATION WITH BOEING AND EXISTING CONDITIONS. LENGTH OF TRANSFORMER SECONDARY CONDUCTORS TO COMPLY WITH NEC ART 240.2I(B). PROVIDE SQUARED ENHANCED ENERCEPT METERING CT'S FOR METERING OF PANELBOARD FEEDER. ENERCEPT CT'S TO INTERFACE WITH BUILDING METERING SYSTEM. PROVIDE 1/2" CONDUIT WITH (1)g 18AWG TWISTED SHIELDED PAIR RS-485 CABLE BETWEEN METERING DEVICES. BELDEN R1120A OR APPROVED EQUAL. DEV. CENTER, WA CURRENT REVISION 131174-00 BOL DATE 12.12.13 SHEET E4S35 OB NO. 6054201-02 CO 0. 09-120-E4S35 LEGEND: SPACE W/CELL KIT 5YM F1 I F2 SPACE 2F2-5 2F2-6 2F2-7 225A 225A 225A 208/120V 208/120V 206/120V RENSION BY APPROVED SUB #35 9-120.1 SPACE W/CELL KIT F4 I - 2N"-3#4/0 & 1((4 C �- (2 2N"-394/0 & 191 C 11 t 1 11 225 KVA �(Y Ti K4 3/0 _C DATE 5YM REVISION SUB #75 SPACE W/CELL KIT F5 I FOR 94 FDR 97 125E 900' 4" TRANSITE- (3) 1/C #350 MCM EP UNDER¢ROUND DUCT BANK 6 1500/2667KVA -48 Z= 5.75% I480Y /277V BY T 3200 AF 2560 AT J APPROVED F6 1 1600 AF 1 600AT j t DATE A SW HYDRAULIC LAB J #780018-00 ERICKSON WHR50N 7-17-98 REVISED BOARDER AISAKA 9-9-08 BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-DO BRIO CEI 12.12.13 F7 1600 AF 600AT IIy� 10,200A AVAILABLE PER SEATTLE CITY LIGHT ATTA 45 KVA 208Y/120 V FB 1600 AF 1200 Al j C9 200A MLO 3PH 3W w E p o tATT > Z= 6.24% F9 T 1600 AF 1200 AT �� z � o 34350 HB 600A MLO PH 3 320 FLA (TOP 2) 2)2 1/2"AL- 3)94/0 & (1)92 GND (TOP 2) XFMR BR 225A 15DA MB 3PH 4W g)Litinrzeirisfc® HAA Ar ThS PA, AhlT F9 200A MLO 3PH 4W 45 KVA C.1 F10 1 1600 AF 1200 AT F9-1 1200A MLO 3PH 3W ow zp At- 320 FLA (TYP 3) 2)2 1/2"AL-(3)94/0 & (1)93 GND a 8 60DA MO 3PH 3 208Y/120 V (TYP 3) ISOL XFMR 'TAT 481 EB 225A 5OA MB 3PH 5W ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN M. DITTMAR DATE 7-5-94 F11 a �Lv 1600 AF �) M 1200 AT , 320 FLA (1YP 3) F9-2 200A MLO 3PH 3W 2)2 1/2"AL- 3)44/0 & (1)93 GND TYP 3) RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER GENERAL NOTES: REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JAN 3 1 2014 City of Tukwila BUILDING DIVISION C• S R TIO IT S: INTERCEPT EXISTING CONDUIT PREVIOUSLY SERVING SUB 36 TIE BREAKER AND EXTEND TO PANEL 2F2-1. PROVIDE NEW CONDUCTORS AS SHOWN. d PROVIDE NEW FEEDER TO SERVE PANEL 2E2-3. PROVIDE NEW 480V:480Y/277V TRANSFORMER TO SERVE LIGHTING PANEL 2F2-3. PROVIDE #8 AWG GROUNDING ELECTRODE CONDUCTOR TO BUILDING GROUNDING LOOP. ®PROCURE FROM BOEING A REPLACEMENT 1200A TRIP SENSOR FOR EXISTING BREAKER. REPLACE SENSOR UNIT AND ADJUST 10 REDUCE LONG TIME TRIP SETTING TO 0.5X (600A). EXISTING PANEL TO REMAIN. PROVIDE A 50A-3P BREAKER IN EXISTING PANEL TO SERVE PANEL 282-1. PROVIDE NEW FEEDER. FEEDER CONDUCTORS 10 BE NO SHORTER THAN 295 FEET. PROVIDE NEW 70A-3P BREAKER 10 SERVE PANEL 2F2-3 VIA TRANSFORMER. PROVIDE NEW 225KVA, COPPER, K4 RATED TRANSFORMER WITH A 80 DEG C RISE AND CLASS 220 INSULATION. TRANSFORMER TO HAVE A MINIMUM IMPEDANCE OF 4.5%. REPLACE EXISTING PANEL BOARD INTERIOR WITH NEW IEM 225A MLO, 3PH 3W, 18kAIC RATED PANEL INTERIOR. PANEL TO HAVE BREAKERS, RATINGS AND OTHER FEATURES AS SHOWN IN PANEL SCHEDULE. 11` REUSE EXISTING FEEDERS. 9-120 ASIC 100% CD ISSUE SUBTITLE ONE LINE DIAGRAM SUBSTATION 75 COFFMAN NGINEERS 1E01 FR10 Avenue, suite 9001 Seattle, WA 98101 ph 100.611A717 I for 200024.3775 LAMING v..nle.e wu.w. CURRENT REVISION 131174-00 SYMBOL B DATE 12.12.13 N GINL hit R. ERICKSON CHECKED APPROVED J. VAVREK APPROVED N. MEHTA 11-16-94 11 /16/94 11/16/94 TITLE BOEING 9-120 ASIC OFFICE MODERNIZATION BUILDING 9-120 ELECTRICAL MASTER DEV. CENTER, WA SHEET E4S75 E* JOB NO. COMP NB. DWG NO. 9-120-E4S75 *OFFMAN N GINEERS 1601 Fifth Avenue, Sulle 900I Seattle, WA 08101 ph 206.623.0717 1.206.624.3775 LASTING w11.4,1 ,I..Mu,M . 9-120 ASI 100% CD ISSU se CONSTRUCTION NOTE SECURE AREA BOUNDRY. MINIMIZE OUANTRY OF CONDUIT PENETRATIONS AND SEAL ALL PENETRATIONS. VIEW STATION STORAGE 21E 1C=SmmSIN � liii! III11II!1iHO1IHIU IY:i► I I 8 � �,' 3 ii 1111111_ ■I■IIIL� i. o ■ImiiI l! F 1111t',:1 <A■111" GII■ [3 1_�I�II��J_� .may �IIIt1�.. �61ILIUMsJ■ III■��fd'31►�1.. 36 I�jR416e>.vem IC--- 3b p� INIIIIR IR1!!!■l 3b iLiimma■ F a ? R: ■IIIIO■ III �Pw i- 111111E II■ I. I;:/6" . _- 'L+J��V1�14_1 �71YG Yalm/�- 1 INIIIIIIII!'U 3b - INFil:l : NUM R' NM NMI IN O W■ 1_L'-..'JIB_ MPLIMITNI WARM 1■rf ;MBA; I11'€�11/a01 l ifflla■\ M illli11TEN 1IAJlIIIkN JI IJIIC?]iliLr Ii 1IA\IIIIi a. : ■!■EI■a111 I•RL"_!■■I I Ilfi■•II1E! INTUIT ili:11INI IIMIII�'.La:lq!! II■IIhII►% YII2 1�i■rI i 1111 L E i IINII!4'l!IIIVI:.! I MIMEO, "u. ■■li__ I,!� PROVIDE LUTRON GRAPHIK EYE OS 6 ZON SCENE CONTROLLER FOR CONFERENCE ROOM. COORDINATE WITH ARCHITECT TO DETERMINE EXACT LOCATION. REFER TO DETAIL 2/2E501, PROVIDE CONTACT CLOSURE MODULE TO INTERFACE GRAPHIK EYE WRH OCCUPANCY SENSOR. LUTRON IOSE-10. REFER TO DETAIL 2/2E501. PROVIDE ETHERNET/RS232 INTERFACE MODULE TO CONNECT GRAPHIK EYE TO AV SYSTEM. REFER TO DETAIL 2/2E501. PROVIDE NEW LIGHTING CONTROL PANEL FOR TIME CLOCK CONTROL OF GENERAL LIGHTING. DOUGLAS #PWEEO SERIES. REFER TO 3/2E501. REVISION 22 TI R22 .� Ilil� ■IIIIIIO■ Eins ImI110 ■ am EIlw !I ■irr ;a1 • tlIigllistilY� 3�ILlf111LeWE!i1�>.rove7Y7t\7.t11=.►,IdJ� li i4 ia• iald HEWN _7L ■IIrt: - imam !ERR: Li__ I' JjI r1_� incElli _� Ei'1r1IP,dRrrrr~IIl1I•I L`✓ai MAMI■1 \fIFin��■■Ill ail_►.=rl... �•�,la gill It1aCo111= !vm ill■III■it • pp IA kirwir I tatt41Sitrif*$404414 �rampumi Viti11 • s'1 r140,, ��11�.1��11 1�� �'w�111111,PJ1�, (R22 R9 PRIMARY ZONE SECONDARY ZONE PRIDE NEW LOW VOL AGE OVER -ID TWO (2) SWITCHES. 0 E (1) FOR CONTROL OF ACCENT LIGHTING (R7,R8,R1 I, R12,R21,R24,R25) AND ONE (I) FOR GENERAL LIGHTING (R4.R6,R9.R10, R13,R19,R21,R22). WIRING BACK TO LIGHTING CONTROL PANEL LCP-2B2-1. PROVIDE NEW PHOTOCELL TO CONTROL FUTURES WITH -IN THE PRIMARY AND SECONDARY DAYLIGHT ZONES. WATTSTOPPER OLS-301. REFER TO DETAIL 5/2E5E1, LUMINAIRES IN THE PRIMARY DAYLIGHTING ZONE MUST BE CONTROLLED SEPARATELY FROM THE LUMINAIRES IN THE SECONDARY ZONE. OR • STATION PROVIDE UL 924 FOR EGRESS LIGHTING. REFER 10 DETAIL 4/2E502. DATE INIER!I I / 26G • EM P-OVIDE NEW ROOM COM-6 ER 8 CEILING ABOVE SWITCH. SINGLE RELAY ON/OFF 0-102 DIMMING. WATTSTOPPER #LMRC-21D SERIES. REFER TO DETAIL 6/2E501. PROVIDE NEW DLM CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR. PROGRAM FOR AUTO-OFF/MANUAL ON. WATISTOPPER Ip'LMDC-100. PROVIDE NEW CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR FOR AFTER HOUR TURN ON OF L EGRESS LIGHTING. WATTSTOPPER #DT-300. PROVIDE NEW WALL MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR, WATTSTOPPER #D1-200. REVISION BY APPROVED R7 R1 R1 R2 1 --••• R2 11111111 431 II R1� R22 II® R2 3/2o u _rrnann..aron R2 0 V MI�1�.1�� EM Al�" 286 / b t` 2G2 202-11/12c R5 ANL L NA • t 0\\ R VETO E5�� VIEW ROOM 1 • ® 1 I!IIIWATAr 2-3/ 5,R6 2 V2: LCP /2G 0 m R3 E1//501 R4 I IX OOMIEW 2 F I,nn I mmam 2-3/R29.R30 •V 2 • • :/ R30 R30 • =m•w.=� RS I FRF4 le TLS11•-5 ., JD 0 • • 8 - r- I • • IV • �v R i L U2E10 E501 R9 VIEW ROOM 5 RB 2102 5 R9 m = L. R9 5 _029 R29 2G2-3/ R5,f{6 LEGEND I Ics I ©o O LIGHTING SCENE CONTROLLER PHOTOCELL CONTROLLER DAYLIGHT ZONE a DLM OCCUPANCY SENSOR 12 CEILING MOUNTED. WATTSTOPPER LMDC-100 D$D DLM SWITCH - DIMMING 4-BUTTON ["% D2$Oo.ObDLM SWITCH - DIMMING 5-BUTTON 12 $CK CONTROLLER KEYPAD SWITCH I DLM I PDSJ I LSMj DLM ROOM CONTROLLER 12 POWER/DATA SUPPLY PROGRAMMABLE LED CONTROLLER REFER TO 2E500 FOR FIXTURE SCHEDULE 1-@o ES I 2E11 WALL MOUNTED OCCUPANCY SENSOR CONTROLLING SWITCH LEG a WATTSTOPPER DT-200. ETHERNET SWITCH 11 0 COC NFPA O - NE JAN 3 1 2014 SEE 2E11 SEE 2E11 LCP 202-3/ P29.R30 R9 R9 1 R9 R9 f2C m LJR 2 SE GE SEE 2E11 2c 131/ _RI2 B2 1/17c W CP 282-1 RELAY 7 R2 2E12 (TYP) SECOND F GOR LIGHTING PLAN 23 SCALE: 1/8•' = 1•- EGRESS LIGHT TO REMAIN UNSWITCHED FOR SECURITY. 13> PROVIDE NEW WALL MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR FOR AFTER HOUR TURN ON OF EGRESS LIGHTING. WATTSTOPPER #DT-200. PROVIDE NEW WALL DLM DIMMING SWITCH. REFER TO DETAIL 6/2E501. PROVIDE WALL MOUNTED ETHERNET CONTROLLER KEYP ' FOR LED ACCENT LUMINAIRES ABOVE CONFERENCE ROOMS. REFER TO DETAIL ON SHEET 2E502 FOR WIRING DIAGRAM. A 9-120 RENOVATION JBI 6054201 02 COFF AN SWEET 07.12.07 BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-00 BR CEI 12.12.13 9 120 RENOVATION A51 07. J$ I605420 02 COFF AN E. SWEET 09.21.07 RECORD DRAWING J$1605420 -02 COFF AN E. SWEET 05.15.08 ADD 4 LIGHTS W1641597 SAZAN/S TAE 05.22.13 RECEPTACLES N DIMMERS W1903392 ESBROOK TAE 05.22.13 cel_AnsrAE,Afc. B 0 City of .Tukwila � � V PROVIDE (1) POWER/DATA SUPPLY FOR CONTROL OF COLOR KINETICS LED ACCENT LUMINAIRES TO LOBBY. REFER TO DETAIL ON SHEET 2E50R FOR WIRING DIAGRAM. COLOR KINETICS 1PDS-6DCA-24V DMx/ETHERNET. 1; REFERENCE DRAWINGS 2E11 SEE 2E11 PROVIDE (7) POWER/DATA SUPPLY FOR CONTROL OF .WIRE 10 NEAREST REC PTACLE. COLOR KINETICS LED ACCENT LUMINAIRES ABOVE CONFERENCE ROOMS, REFER TO DETAIL ON SHEET EXTEND EXISTING EGRESS . COLOR KINETIC CIRCUIT AS SHOWN. RNET. LUMINAIRE TYPE El TO BE NIROLLER FOR CONTROL OF MOUNTED ON GYP CEIL G FOR T LUMINAIRES ABOVE INDIRECT LIGHTING OF 2E502 FOR WIRING DIAGRA #PDS-60CA 24V DMx/ETH PROVIDE PROGRAMMABLE C COLOR KINETICS LED ACCE 9� REFER CONFERENCE ROOMS. PRE PROGRAMMED WITH A SLOW CORRIDOR. ROOM. ROB FADE OVER A 10-HO R PERIOD, WITH WALL BOX CONTROLLER KEYPAD FOR NUAL OVERRIDE OF COLOR D>LED TAPE LICHT AT BO TOM OF EETEX008 GYP DESK_AND U 7 AT 110 DOUGLAS LIGHTING CONTROL SFTTINGS._BEFE WIRING DIAGRAM. COLOR KINETICS LIGHT SYSTEM MANAGER. COLOR KINETICS LED ACCENT FIXTURES TO BE CONTROLLED BY CONTROLLER KEYPAD. KEYPAD LOCATED NEXT TO OFFICE ASSISTANT 23A3. POWER SUPPLY AND PROGRAMMABLE CONTROLLER ARE LOCATED IN CEILING ABOVE CONFERENCE ROOM 21 B4, EXIT SIGN TO BE WIRED TO UN -SWITCHED CIRCUIT, LUMINAIRE TYPE W TO BE PROVIDED BY ELECTRICAL CONTRACTOR. REFER 10 LUMINAIRE SCHEDULE ON 2E500 FOR SPECIFICATION AND TYPICAL MODULE MOUNTING DETAIL. ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED TOP OF DESK. REFER 10 ARCHITECTURAL FOR MOUNTING DETAILS. LED TAPE TO BE MOUNTED AT TOP OF COLUMN. REFER TO ARCHITECTURAL FOR MOUNTING DETAILS. PROVIDE UNMANAGED 8-PORT INDUSTRIAL ETHERNET SWITCH MOUNTED ABOVE ACCESSIBLE CEILING SPACE. CIRCUIT 10 NEAREST 120V CIRCUO NTRON OR APPROVED EOUAL. PROVIDE 24VDC TRANSFORMER AS REQUIRED. DRAWN COFFMAN CHECKED E. SWEET NIINLIA CHECKED APPROVED JOHN J. VAVREK APPROVED 3/2E501. n>REFER TO 5/09-120-2E501 FOR PHOTO CELL WIRING DIAGRAM. 7> WATTSTOPPER DLM SYSTEM, REFER TO 6/2E501, 1-% iCOLOR KEYPAD. REFER TO 09-120-2E502. 1-i UL924 RELAY SERVED FROM NORMAL AND EGRESS CIRCUITS SHOWN REFER TO 09-120-2E501. [282-1/5c VIA LCP 2B2-1 RELAYS 1,R3,R7,R9,R10,R11,R12,R2' & 282-1/5c UNSWITCHED 16. REFER TO ARCHITECTURAL FOR LUMINAIRE MOUNTING DIMENSIc'NS 09-120-2E 50D 09-120-2E501 09-120-2E502 B8 108 m m m 410 H 20 55 m tlEk `EY JUL ACE1 WY WY Elk 0 0 1.) ALL CONDUIT TO BE 1/2" EMT U • ' 1. 1 2.) ALL WIRE TO BE #12 THWN UNLESS OTHERWISE NOTED 3.) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL I OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480 "A" PHASE LEFT BUS IN PANEL) BLACK BROWN "B" PHASE (CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EOUIPMENT GROUND GREEN 4.) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. EXIT SIGN LUMINAIRE IDENTIFICATION "X" DENOTES LUMINAIRE TYPE "Y" DENOTES TOTAL LUMINAIRE WATTAGE OCCUPANCY SENSOR - CEILING MOUNTED LINE VOLTAGE SWITCH SWITCH - OCCUPANCY SENSOR SWITCH - LOW VOLTAGE SWITCH - DIMMING RECESSED 1X4 FLUORESCENT LUMINAIRE PENDANT 8' LINEAR FLUORESCENT LUMINAIRE RECESSED FLUORESCENT DIRECTIONAL LUMINAIRE LED SPOT LUMINAIRE LED SPOT LUMINAIRE 4' SURFACE FLUORESCENT STRIP LUMINAIRE COLOR CHANGING LED COVE LUMINAIRE RECESSED LED DOWNLIGHT LED UNDERCABINET LUMINAIRE 4' SURFACE LINEAR FLUORESCENT LUMINAIRE LED TAPE LUMINAIRE RECESSED 8• DIRECT FLUORESCENT LUMINAIRE I RECESSED 16' DIRECT FLUORESCENT LUMINAIRE WALL MOUNTED LED LUMINAIRE PENDANT 24" DECORATIVE LED LUMINAIRE PENDANT 35" DECORATIVE LED LUMINAIRE WALL MOUNTED LINEAR FLUORESCENT LUMINAIRE PENDANT LED CYLINDER DOWNLIGHT PENDANT LINEAR FLUORESCENT INDIRECT/DIRECT I lu T O 6 1x8, PENDANT DIRECT LED LUMINAIRE 2x4, RECESSED DIRECT/INDIRECT LUMINAIRE 1x4 INDUSTRIALLUMINAIRE FLUORESCENT LU E FIXTURE ON EMERGENCY CIRCUIT 1x4, SURFACE MOUNT LENSED LUMINAIRE PENDANT DOWN LIGHT, NON DIMMING BALLAST RECESSED DOWN LIGHT, NON DIMMING BALLAST EAR SIGN 5.) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK �?_ ... _ IJ€ G N Y_sd4 �CI� SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSW''. 6.) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3 7.) DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION, 8.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF TO 2/09-120-2E501 FOR LIGHTING SYSTEM IN THIS PANEL. REFER TO DATE SUBTITLE 05.23.07 05.23.07 06.01.07 TLE SECOND FLOOR LIGHTING PLAN BOEING 9-120 ASIC OFFICE MODERNIZATION ELECTRICAL MASTER BUILDING 9-120 WILA 14 KEY PLAN SCALE NONE CURRE REVISION 131174-00 F 2.12.13 EFT JOB NO COMP NO. SEE 2E10 282-1/11c, VIA LCP 2B2-1 RELAYS R5,R14.R15,R16 R17,R18,R19,R20 SEE 2010 T L7E `a F,..��-�11IU1Il��► L ,�G R F2r ��2[y A , L1C,IMIMMAA E����I�f 117CMIEriaCER•i `•___ ____\O `IP � E'i rf Mill ! 1 '��I7s gat► iragagOkariviiinorwmi ZI 4i Walla � �l i i►© !+'� a 14111ari I111r11m�1 !Milli IBaal O grin Ili I ILoa�m Rl.56E■■. -I-.1IIWitt�I�-I■. '_■rii�ii�■�■■■. FLOOR PLAN Alb l II II SY REVISION APR 0 DATE SY RE ION APPROVED TE A BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-00 BR CEI 12.12.13 12c /Y['23 EM I'Ati J\R23 41% 1 �tC . E LI EFOWITH -F— NFP/00 NECCO�P� JAN 31?014 City Of .Tukwila BUILD1 , G DIVISION NE O E 17, 12c ,41 17c E 1 SEE 2E13 EM ROVIDE WATTSTOPPER LMLS-500 PHOTOCELL FOR DAYLIGHT pppmMINC OF PRIMARY AND SECONDARY DAYLIGHT ZONE. CONNEC TO 0LM ROOM CONTROLLER. FROVIDE LMSW-104 WALL SWITCH, CONNECT TO DLM ROOM CONTROLLER. ROVIDE WATTSTOPPER CORNER MOUNTED OCCUPANCY SENSOR PART LMDX-100. ROVIDE UL 924 RELAY TO ALLOW FOR EGRESS LIGHTS TO BE WITCH WITH ROOM SWITCH LEG C. 122> LUMINAIRE TYPE E1 TO BE MOUNTED ON GYP CEILING FOR INDIFECT LIGHTING OF CORRIDOR. ROVIDE (7) POWER/DATA SUPPLY FOR CONTROL OF COLOR INEIICS LED ACCENT LUMINAIRES ABOVE CONFERENCE ROOMS. EFER TO DETAIL ON SHEE1 2E205 FOR WIRING DIAGRAM. COLJR KINETIC #PDS-60CA 24V DMX/ETHERNET. LEGEND Ics 1 LIGHTING SCENE CONTROLLER PHOTOCELL CONTROLLING DAYLIGHT ZONE "a" o® OCCUPANCY SENSOR - CEILING MOUNTED WATTSTOPPER DI-300 LINE VOLTAGE SWITCH $os SWITCH - OCCUPANCY SENSOR $LV SWITCH - LOW VOLTAGE $D SWITCH - DIMMING DLM OCCUPANCY SENSOR 10 CEILING MOUNTED. WATTSTOPPER LMDC-100 D$D DLM SWITCH - DIMMING 4-BUTTON110 02$Da,DbDLM SWITCH - DIMMING 5-BUTTON 110 1 DLM I DLM ROOM CONIROLLER 0 WATTSTOPPER LMRC-210 TES REFER TO 2E500 FOR FIXTURE SCHEDULE ® PENDANT MOUNTED 277V EXIT LUMINAIRE �-{ WALL MOUNTED 277V EXIT LUMINAIRE ® 480/277V DISTRIBUTION PANEL Ida WALL MOUNTED OCCUPANCY SENSOR CONTROLLING SWITCH LEG a WATTSTOPPER DT-200. PROGRAMMABLE LED CONIROLLER ETHERNET SWITCH I LSMI I ES I CONSTRUCTION NOTES PROVIDE NEW CEILING MOUNTED DUAL 1ECHNOLOGY OCCUPANCY SENSOR FOR AFTER HOUR TURN ON OF EGRESS LIGHTING. WATTSTOPPER 0D1-300. PROVIDE NEW PHOTOCELL TO CON1ROL FIXTURES WITH -IN THE PRIMARY AND SECONDARY DAYLIGHT ZONES. WATTSTOPPER NLS-301. REFER TO DETAIL 5/E501. PROVIDE NEW LOW VOLTAGE OVERRIDE STATION WI1H TWO (2) SWITCHES. ONE FOR CONTROL OF ACCENT LIGHTING (R19,R20.821,R23) AND ONE FOR GENERAL LIGHTING(R14,R16,R18,R5,R15,R17,R21). WIRING BACK TO LIGHTING CONTROL PANEL LCP-2B2-1. I LUMINAIRES IN THE PRIMARY DAYLIGHTING ZONE MUST BE CONTROLLED SEPARATELY FROM THE LUMINAIRES IN THE SECONDARY ZONE. [' PROVIDE NEW ROOM CONTROLLER IN ACCESSIBLE CEILING ABOVE SWITCH. SINGLE RELAY ON/OFF 0-10V DIMMING. WATTSTOPPER OLMRC-210 SERIES. REFER TO DETAIL 6/2E501. © PROVIDE NEW OLM CEILING MOUNTED DUAL 1ECHNOLOGY OCCUPANCY SENSOR. PROGRAM FOR AUTO-OFF/MANUAL ON. WATTSTOPPER #LMDC-100. PROVIDE NEW WALL MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR. WATTSTOPPER 9DT-200. VIDE UNMANAGED 8-PORT INDUSTRIAL ETHERNET SWITCH NILU ABOVE ACDEJ5I1,ILL LLIDRG SHALL. CIRCU CIRCUIT NTRON OR APPROVED EQUAL. IRA REFERENCE DRAWINGS 09-120-2E500 09-120-2E501 09-120-2E502 RECEIVED CITY OF TUKWILA JAN 1 4 2014 COORDINATE FIXTURE LOCATION WITH EXISTING MECHANICAL EOUIPMENT. EGRESS LIGHT 10 REMAIN UNSWYCHED FOR SECURITY. COLOR KINETICS LED ACCENT LUMINAIRES TO BE CONTROLLED BY CONTROLLER KEYPAD. KEYPAD LOCATED NEXT TO OFFICE ASSISTANT 23A3. POWER/DATA SUPPLY AND PROGRAMMABLE CONTROLLER ARE LOCATED IN CEILING ABOVE CONFERENCE ROOM. PROVIDE NEW WALL DLM DIMMING SWITCH. REFER TO DETAIL 6/2E501. LUMINAIRE TYPE W TO BE PROVIDED 8Y ELECTRICAL CONTRACTOR. REFER TO LUMINAIRE SCHEDULE ON 2ESOD FOR SPECIFICATION AND TYPICAL MODULE MOUNTING DETAIL, PROVIDE NEW WALL MOUNTED OCCUPANCY SENSOR SWOCH. PROVIDE NEW CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR FOR AFTER HOUR 1URN ON OF EGRESS LIGHTING. WATTSTOPPER 9'D1-30D. PROVIDE LUTRON GRAPHIK EYE OS 6 ZONE SCENE CONTROLLER FOR CONFERENCE ROOM. COORDINATE WITH ARCHITECT TO DETERMINE EXACT LOCATION. REFER TO DETAIL 2/2E501. PROVIDE ETHERNET/RS232 INTERFACE MODULE TO CONNECT GRAPHIK EYE 10 AV SYSTEM. REFER TO DETAIL 2/2E501. WIRE TO RECEPTACLE BELOW. g,..___AWASFAEZAW* 9-120 ASIC 100% CD ISSUE ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED B PT. DATE DRAWN D.R. CHESTERFIELD CHECKED DA1E 5\25\93 SUBTITLE C C I 1 I 1 I I RECESSED 1X4 FLUORESCENT LUMINAIRE 8' LINEAR FLUORESCENT PENDANT LUMINAIRE RECESSED LINEAR FLUORESCENT WALL WASH LUMIN LED SPOT LUMINAIRE LINEAR FLUORESCENT FLOOD LUMINAIRE COLOR CHANCING LED COVE LUMINAIRE RECESSED LED DOWNLIGHT LUMINAIRE LED UNDERCABINET LUMINAIRE 4' SURFACE LINEAR FLUORESCENT LUMINAIRE 12' LINEAR FLUORESCENT WALL WASH LUMINAIRE RECESSED 8' DIRECT FLUORESCENT LUMINAIRE WALL MOUNTED LED LUMINAIRE RECESSED LINEAR FLUORESCENT TROFFER LINEAR DIRECT/INDIRECT LINEAR FLUORESCENT LINEAR DIRECT LINEAR FLUORESCENT GENERAL NOTES 1.) ALL CONDUIT TO BE 1/2" EMT UNLESS OTHERWISE NOTED. 2.) ALL WIRE TO BE #12 THWN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 60D VOLTS OR LESS. 120/208V 277/480V •'A•• PHASE (LEFT BUS IN PANEL) BLACK "B" PHASE (CENTER BUS IN PANEL) RED "C" PHASE (RIGHT BUS IN PANEL) BLUE NEUTRAL WHITE EOUIPMENT GROUND GREEN BROWN ORANGE YELLOW GRAY 4.) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE, 5.) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAY, 6.) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3 7.) DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC.. WITH CIRCUIT IDENTIFICATION. B.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. ) > WATTSTOPPER LMLS-500 PHOTOCELL. 110 > WATTSTOPPER DLM SYSTEM. REFER TO 6/2E501. => REFER TO 2/09-120-2E501 FOR LIGHTING SYSTEM IN THIS ROOM. [i WATTSTOPPER LMDX-100 OCCUPANCY SENSOR. r-i UL 924 RELAY, WIRE PER 4/2E501. 14.) REFER TO ARCHITECTURAL FOR ALL LUMINAIRE MOUNTING DIMENSIONS AND HEIGHTS. A OFFMAN NGINEERS 1801 Fifth Avenue, Bulte BOO Seattle, WA88101 pn 2013.03e.0117 11.. 20e.1 4.eT1e .AsnNo .....,I...t�+r. FLOOR PLAN 2E10 2E11 CURRENT REVISION 131174-00 SYMBOL 01 O DATE 2.12.13 CHECKED APPROVED APPROVED LE BOEING 9-120 ASIC OFFICE MODERNIZATION ELECTRICAL MASTER BLDG. 9-120.2 COL. A-F/5-9 D.C. SHEET 2E12 JOB NO. COMP N0. C N0. 9-120-2E12 55,1 SEE S- E i E 2E12 L R29 I FT R29 A!} REVISION SECOND FLOOR LIGHTING PLAN SCALE: 1/8" = 1' 0" BY APPROVED DATE SYM REVISION R29 R29 GEE- SEC 2E11 2E `=7jlibliiiimlimiriii� iTeliEurei Ilrililli IL* ...6; 'a9•UIU51:rJILSZC BY APPROVED LATE A 9-120 RENOVATION J416054201-02 COFFMAN E. SWEET 07.12.07 RECORD DRAWING Jff16054201-02 COFFMAN E. SWEET 05.15.08 BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-D0 BRM CET 12,12.13 0 'A R2D 02-3/0 OS 12c SE STAIR e#' 21J7 ION FOE/AW MIK I I RECESSED LINEAR FLUORESCENT WALL WASH LUMINAIRE O RECESSED LED DOWNLIGHT LUMINAIRE o- 4' SURFACE LINEAR FLUORESCENT LUMINAIRE REVIEWED FOR CONFpA NC NECK JAN 3 1 2014 JAN 3 1 2014 City of .Tukwila 31JILDING DIVISION ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN COFFMAN E.. SEU SWWEET 1NCMLLH SREESED APPROVED APPROVED DATE 05.23.07 05.23.07 LEGEND TYPE DESCRIPTION LAMPS MOUNTING 30-27UER #K'W-4-A-2- 32-277-SO F3218/356 SURFACE R LICMOLIER I'ES-O-G-X- 3W LED UNIVERSAL RC-C-N Cl I 1 x4, RECESSED INDUSTRIAL LUMINAIRE FIXTURE ON EMERGENCY CIRCUIT EXn SIGN LUMINNRE IDENTIFICATION "X" DENOTES LUMINAIRE TYPE Y DENOTES TOTAL LUMINAIRE WATTAGE OCCUPANCY SENSOR - CEILING MOUNTED WATTSTOPPER DT-300 SWITCH GENERAL NOTES 1.) ALL CONDUIT TO BE 1/2" EMT UNLESS OTHERWISE NOTED. 2.) ALL WIRE TO BE #12 THHN/THWN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/4BOV "A" PHASE (LEFT BUS IN PANEL) BLACK BROWN "B" PHASE (CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE CRAY EQUIPMENT GROUND GREEN 4.) LARGE SIZE CONDUCTORS WHICH D0 NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRLATELY COLORED TAPE. 5.) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAY. 6.) FEEDERS 10 PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3 7.) PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUO IDENTIFICATION. B.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB, 9. VERIFY ROTATION OF ALL 3 PHASE MOTORS 10.) REFER 10 ARCHIECTURAL FOR ALL LUMINNRE MOUNTING DIMENSIONS AND HEIGHTS. 11.) REFER 10 9-120-2E500 FOR LUMINNRE SCHEDULE. REFERENCE DRAWINGS 9-120-2E500 CONSTRUCTION NOTES E> PROVIDE NEW LUMINNRES, WIRING AND CONTROLS AS SHOWN. RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER 9-120 ASIC 100% CD ISSUE SUBTITLE TITLE SECOND FLOOR LIGHTING PLAN BOEING 9-120 ASIC OFFICE MODERNIZATION ELECTRICAL MASTER BUILDING 9-120 COL. F-K/5-9 DEV. CENTER, WA KEY PLAN SCALE: NONE 0 8' 4' 0 4' 8' 16' SCALE: 1/8"=1'-0" &COFFMAN NGINEERS 1601 Finn Avenue, Sure BOO Seattle, WA 98101 In 206421011V I hx 206621.4115 wNmen,rom LASTING m .L.AANTLGA N CURRENT REVISION 131174-00 SYMBOL B DATE 12.12.13 SHEET 2E13 E* JOB NO. COMP No. 16054201-02 Dwc ND. 09-120-2E13 [7:>- PROJ SCREEN SHADES SHADES-' CD 282 MIR it OFFICE IRE OFFI 282-4 37o.39 10b 10b • rep snag COLLABORATION SPACE 2 12c I40 16b ANTRPlink 'Y Ii1 I ;;;yyy ' il 1.1 o,33b,3 L j.-.I MCI -"F��+�-' wpT •;I��I,r�•1 41c 39�„f NW STAIR C�!'�III 12�rYFYl Lam'II�IB�'�/'i�I�\ 21B1 1511 3/5c,7o,9 282-3/3b, 17c 190 21 ROOM 4o I6b 282-3/4b 6c,8o OFFIC S _ AN 282-4/250,27b29c R -----\-- CO JAN 31 7014 City of'Tukw{ Tukwila BUILDING DIVISION REV,. 80 APPROVED DATE FREIGHT ELEV. /23c.250,27b,29c /31.„3SATE LLIT E�f_ 37o ONO ' 4 4 4 33b LLCD I-ALLWAY SIC f4 0 282 3/ 22b,24c,260 10 DA/T2'AC R00M 22D6 1 i U D 282-4/70,96 RECEPTION 282-4/10,31,5c 282-4/247,4b,6c` 4c 1F2- 2B2-4/200,22b,24 9-120 ASIC 100% CD ISSUE JANITOR 22. oo ° LCD PUHBUTTON 1/ • (11)52 R 1118 BS>PUSHBUTTS 282-4/19o,21b.23c (TYP)1>. (TYP) 2B2-5/15b _J_ _J__ _I_ _111,4 2A7-4/20o SYM REVISION 80 APPROAD VIEW STATION STORAGE ptf 2E2-5/174,19°,2o, b 16b p 2F2-5/6c,80,1015 2F2-5/14°,166.1 Bc 10 2F21-5/10,36,5c #1 ,�I( q Ltrg ef:IkEg�l �'�T•_G71r .Lt 5 FS/20D DOWN TO.IE� SECUR 1ST. FLR. SEE 1E6D PANEL COFFEE BAR }t'w-10/320,346,.. 3 MR C 442480o C REN 90 15= 1Eb 3:t = 21b D. 7/Y j1 r IL91 E P jL91 u I I PLAN SCALE: 1/8" = 1.-0" D41E PROVIDE DOOR BELLS WO#834 B956 SANTOS VAVREK 2/24/09 9-120 RENOVATION RFI 158 JB16054201-02 COFFMAN E. SWEET 10.03.07 INSTALL POWER 9-120.2 LIGHTHOUSE 72879699 VAVREK VAVREK 02.24.12 9-120 RFI 080 416054201-02 COFFMAN E. SWEET 11.09.07 THEATER 1 4PLEX OUTLETS W1383372 "ME ESBROOK 11.12.12 RECORD DRAWING J111 6054201 - 02 COFFMAN E. SWEET 05.15.08 BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-00 BRM CEI 12.12.13 THEATER RECEPTACLE CHANCES J;)7915338 MOBERG VAVREK 10.20.013 DESIGN 110V OUTLET 4/8425298 VAVREK VAVREK 02.09.09 2F2-5/21b,23c,25o CEILING MTD.QD38o 1 Taw` assume -Anil II AIl11• ■T"- : ' 2F2-1 27 E 10/18c 2F2-I 1/7o,9b VIEW ROOM 5 I4o VIEW RO 2F2-5 1'�'i•',4c, •° 12F2-6/38 25G SEE 2E61 OA N1EW ROOM 2 - 1 2" (1) 2F2-II/20,41).8e 5 _ 2P2-11/5c 5 Sc ,; Sc CON ""�-:: - ...20o 13/20o DOWN b1s;Vi7 1ST. FLR. SEE IE60. Sc 2F2-9/226.24c.26o 2F2-9/ 4o,I6b.T8c.20o 2F2-9/6c,8G.10b 2F2-9/17c,190,20,4b 5c 212-9/21b,23c,25o t. , 6c C/l12AWG C CABLE 1E675° PR '+B 2F2-9/1o.36,5c 2F2-9/9b.11 ,13o,15b V V V V V V ", YY33'-S 3► PROVIDE CONNECTION TO UNDER CABINET WAT R HEATER. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR. x x x x x x x MOUNT RECEPTACLE AND AV BOX FOR POLE MOUNTED LCD MOUNTED IN UNISTRUT FRAMED WALL. ROUTE CONDUIT DOWN WITHIN UNISTRUT STRU URE 10 RECEPTACLE. COORDINATE EXACT LOCATION, MOUNTING HEIGHTS AND CONDUIT ROUTING WITH ARCHITECT AND ARCHITECTURAL WALL DETAILS. COORDINATE AV BOX LOCATIONS AND CONDUIT WITH AV DRAWINGS. PROVIDE OVERFLOOR RACEWAY FOR POWER AN DATA BELOW TABLE. SURFACE RACEWAY TO BE WIRE OLD OFR SERIES WITH RECEPTACLE. DATA AND AV MOUNTED IN UNDER TABLE OFR48-4 DEVICE X. COORDINATE WITH AV AND PROVIDE PARALLEL UNS OF OVERFLOOR RACEWAY AS RE UI ED ACCOMMODATE AV CABLING. COORDINATE EXACT ROUTING WITH ARCHITECT. PROVIDE POWER CONNECTION AND SWITCH FOR PROJECTOR SCREEN. INTERFACE WITH AV SYSTEM. COORDINATE WITH AV CONTRACTOR AND ARCHITECT FOR SWITCH QUANTITIES AND LOCATIONS. ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT, DATE DRAWN COFFMAN E. SWEET SWEET DATE 05.23.07 05.23.07 CONSTRUCTION NOTES JUNCTION BOXES FOR AV WITH CONDUIT BETWEEN BOXES AND CONDUIT FROM UPPER BOX TO ACCESSIBLE CEILING SPACE. COORDINATE BOX LOCATIONS WITH ARCHITECT PRIOR TO ROUGH -IN. REFER TO AV DRAWINGS FOR JUNCTION BOX AND CONDUIT SIZES AND LOCATIONS. PROVIDE CEILING MOUNTED RECEPTACLE FOR PROJECTOR. PROVIDE POWER CONNECTION AND BACKBOX FOR CONTROL PANEL (CP). COORDINATE WITH AV DRAWINGS FOR EXACT REQUIREMENTS AND LOCATION PRIOR TO ROUGH -IN. PROVIDE RECEPTACLE FOR WALL MOUNTED MONITORS. PROVIDE TWO -GANG 3;"D JUNCTION BOX WITH (1) 1Y2"C TO ACCESSIBLE CEILING SPACE FOR AV. COORDINATE BOX LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. PROVIDE POWER CONNECTION FOR MATRIX SWITCHER (MS). COORDINATE WITH AV CONTRACTOR FOR ADDITIONAL REQUIREMENTS. PROVIDE POWER CONNECTION AND SWITCH FOR MOTORIZED SHADES INTERFACE WITH AV SYSTEM. COORDINATE WITH AV CONTRACTOR AND ARCHITECT FOR SWITCH QUANTITIES AND LOCATIONS. MOUNT ABOVE COUNTER. COORDINATE EXACT HEIGHT WITH ARCHITECT. • MOUNT RECEPTACLE IN CREDENZA FOR AV EQUIPMENT. COORDINATE MOUNTING HEIGHT FOR EACH LCD RECEPTACLE WITH ARCHITECT PRIOR TO ROUGH -IN. PROVIDE CONDUIT BETWEEN ACCESSIBLE CEILING SPACE AND POKE THRU FOR AV. REFER TO AV DRAWINGS FOR CONDUIT SIZE AND ADDITIONAL REQUIREMENTS. PROVIDE RECEPTACLE SURFACE MOUNTED TO RECEPTION DESK FURNITURE. HOME RUN CONDUITS TO BE 3/4"C MINIMUM. PROVIDE 1"C WHERE #10 AWG CONDUCTORS ARE SHOWN. INSTALL HILTI PUTTY PADS ON ALL IN WALL BACKBOXES LOCATED IN CONFERENCE ROOMS, PROJECT ROOMS AND ANY OTHER ENCLOSED SPACES WITH LCD MONITORS. PROVIDE 1/2"C FROM JUNCTION BOX LOCATED ON THE SECURE SIDE OF THE DOOR TO CARD READER JUNCTION BOX. COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH SECURITY VENDOR. PROVIDE 1/2" CONDUIT FROM JUNCTION BOX ON THE SECURE SIDE OF THE DOOR TO THE REQUEST TO EXIT DEVICE AND ELECTRONIC STRIKE. COORDINATE EXACT LOCATIONS AND PATHWAY WITH SECURITY VENDOR. PROVIDE CONDUIT BACK TO SECURITY PANEL IN DATA ROOM 22D6. COORDINATE EXACT LOCATION WITH SECURITY VENDOR. PROVIDE PATHWAY AND ROUGH -IN FOR SECURITY DEVICES INSTALLED UNDER THIS PROJECT. COORDINATE EXACT DEVICE LOCATIONS AND TERMINATION POINTS WITH SECURITY CONTRACTOR. PROVIDE CONDUIT TO MAGNETIC HOLD OPEN FOR SECURITY WIRING. COORDINATE EXACT DEVICE LOCATION WITH SECURITY VENDOR. PROVIDE 1/2" CONDUIT TO JUNCTION BOX FOR EMERGENCY RELEASE. COORDINATE DEVICE LOCATION WITH SECURITY VENDOR. WALL MOUNTED LCD. TYPICAL FOR ALL HOTEL ROOMS, PROJECT ROOMS, AND CONFERENCE ROOMS. PROVIDE CONNECTION TO GRAFIK EYE SCENE CONTROLLER. PROVIDE WIREMOLD 8AT POKE-THRU WITH TWO DUPLEX RECEPTACLES. COORDINATE EXACT LOCATION WITH ARCHITECT. REFER TO AV DRAWINGS FOR LOCATIONS AND SIZES OF JUNCTION BOXES FOR AV CABLING AS WELL AS CONDUIT BETWEEN BOXES AND UP TO CEILING SPACES. SUBTITLE SECOND FLOOR 208Y/120V POWER PLAN LEGEND DUPLEX RECEPTACLE DOUBLE DUPLEX RECEPTACLE POKE THRU CEILING MOUNTED RECEPTACLE EQUIPMENT CONNECTION PEDESTAL DOUBLE DUPLEX RECEPTACLE CARD READER REDDEST 10 EXIT DEVICE ELECTRIC DOOR STRIKE MAGNETIC HOLD LOCK AV CONTROL PANEL AV MATRIX SWITCHER AV LCD BACK BOX AV JUNCTION BOX 2fLCD DUPLEX RECEPTACLE FOR LCD SM HORSE POWER RATED MANUAL STARTER SWITCH GENERAL NOTES I. ALL CONDUIT TO BE I/2" EMT UNLESS OTHERWISE NOTED. 2, ALL WIRE TO BE 112 THHN/THWN UNLESS OTHERWISE NOTED, 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS ADO VOLTS OR LESS. 120/208V 277/480V "A" PHASE (LEFT BUS IN PANEL) BLACK BROWN "B" PHASE (CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAY. 6. PERMANENTLY LABEL ALL RECEPTACLES. JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 7. INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. B. VERIFY ROTATION OF ALL 3 PHASE MOTORS. 9. COORDINATE CONDUIT ROUTING AND JUNCTION BOX LOCATION WITH ARCHITECTURAL REFLECTION CEILING PLANS. CONDUITS TO BE GROUPED TOGETHER AND ROUTED PARALLEL OR PERPENDICULAR 10 BUILDING LINES. ALL EXPOSED CONDUIT SHALL BE PAINTED TO MATCH THE SPACE IT IS INSTALLED IN. I0 > OVERFLOOR RACEWAY. WIREMOLD OFR SERIES. RECEIVED CITY OF TUKWILA JAN 1 4 2014 8' 4' 0 4' 8' 16' = I 11 SCALE: 1/8"=1'-0" ACOFFMAN NGINEERS 1601 Fifth Avenue, Sulle 900I Seattle, WA 98101 Ph 2066234M fax 400.6244770 effmNrmm LASTING w"n,w.r iw.w. CURRENT REVISION 131174-DO SYMBOL p DATE 12.12.13 ENGINEER CHECKED APPROVED APPROVED TITLE BOEING 9-120 ASIC OFFICE MODERNIZATION ELECTRICAL MASTER BUILDING 9-120 COL. A-F/1-5 DEV. CENTER, WA SHEET 2E60 E* J06 N0. DWG NO. 8348956 09-120-2E60 COMP N0. eve 41111 2F2- 6/38o SEE 2E60 3/4"C.O. 2F1-6/ 3/("C, 10112,112 CRD. 2F2F-6/lo,3b,5c,70,9b SEE 2EAD 1/2" (1) 2PR #18 2F2-10 2F2-11 - - 50, MEC 2F2-1I/190 480-208Y/120V REVISION 36 ' 2DA 4b 3C/#12 MC CABLE (6T(P) 2F2-1 /21b DIM DIM LCP 1F2-9 212- OOKVA 2F2- T 2F2- BY 25o 21'12,112G DED 20A 37c 3/4"C.O. 2F2-6/ 3/4'C, 10fI2,1% 2 GRD. 2F2-6/11c,13o, 5b,I7c,190 3/4"C, 6 12,2f10. 212-6/276,33a,35b, 3/4"C, 8112,112 2F2-6/320.346,3 3/4"C, 6112,21 2F2-6/2 F2-II/13o, 5b 2C3-2 38a,40b,42c 203-2/3}20,34b,36c 2C /26a,28b,30c iu (3 (T(Df 3, (3 2G3-1/35o 40b.42c 203-1 //3t5o,34b,3 c C3-1 26a,28b.30c 3 (3, (3) (3),. (3 12GRD. 7c GRD. c,38o '35b 2F2- 10/26o.286.30c XFMR, 120-24V 60" LCD 2F2-8/27.29 203-2 203-1 :5//iio:33g:4}51O 203-2/25a,27b,29c 2C3-2/1o.3b,5c 203-2/7a,9b 11c 2G3- 2/130.15b.17 203- 2/190.2 I b,23c 2C3-2/2Oo,22b.24c 2G3- 2/14o,16b,18 2C3-2/2a,4b.6c 203-2/8°,101,12c 3 20A(63 TYP) APPROVED DATE SYM 2 qq G3-/ 2G3 10 '��� oIDb,�a,3b /BTUcb.8c 4o 16b,1Bc b.24c REVISION 2F2-: 3/4"C, 2F277/2 2F2- 7/9b,11c,13o,15b /1o,3b,5c,7a. 8112112 CRD. 3/4"C, 6/12./1112 CRD. MOUNT RECEPTACLES TO CABLE TRAY I =_ 2F2-5/27b (SMOKE DAMPERS 1/2" (1) 2PR 118 28b 2G3 1/5c,70,9b.1 203-1/1 TO SEC DOOR BELL 2F2-10 2F2-1E :, 0 4F n' 8 2F2- 1D/2,4,5 20-1 15.17.19.21.23.25 I/2"C, 6110,110 2F2-10/21 PLAN VIEW E10 /1. /10 2F2- 7/17c,190,2a,4b 1A 2F2-7/6c,861Db,1 3/4"C, 811121112 ORE. 2F2-7/22$b,�4c,26o 3/4 C, 61112.112 CRD, 212-10/19 212-8/21,23.25 BY SCALE: 1 /8" = 1'-0" APPROVED DATE THEATER 2 DEDICATED CIRCUITS 22E2 W1903392 SAZAN/SL 05.20.13 9-120 RFI-080 J116054201-02 COFFMAN E. SWEET 11.09.07 BOEING 9-12D AOE OFFICE MODERNIZATION - PH1 131174-DO BRM CEI 12.12.13 H RECORD DRAWING PROVIDE DOOR BELLS J1116054201-02 WO#8348956 COFFMAN SANTOS E. SWEET VAVREK 05.15.08 2/24/09 9-120 RENOVATION ASI #05 J416054201-02 COFFMAN E. SWEET D8.29.07 THEATER 3 4PLEX OUTLETS W1383372 ESBROOK TAE 11.12.12 9-120 RFI 61 Jff160542D1-02 COFFMAN E. SWEET 09.21.07 INSTALL POWER 120-2 LIGHTHOUSE 12879699 VAVREK VAVREK 02.24.12 'MO 212-10/I 2F2-1D/17 2F2-110/23,25 01 ci._45,17EZAW ® X03-13a 2F FIRE SPRINKLER CONTROL CRCARD READER REXREQUEST TO EXIT DEVICE m ELECTRIC DOOR STRIKE EC W/ FAN O REVIEWED FOR CONFPA OC NECTH JAN 31 2014 City of Tukwila BUILDING DIVISION 0 AFOFFMAN NGINEERS 1601 Fifth Avenue, Sule BOO I Seattle, WA 98101 ph 200023.0717 110x 200134.3170 camm.nxon, DATING ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN COFFMAN DATE 05.23.07 2HEC ALL) E. SWEET 05.23.07 LEGEND it DUPLEX RECEPTACLE DOUBLE DUPLEX RECEPTACLE O POKE THRU t SPECIAL RECEPTACLE (NEMA L6-30R) POWER POLE CEILING MOUNTED RECEPTACLE NEMA 15-20R RECEPTACLE Cc) CHIME, SINGLE -STROKE, 24V EDWARDS #338-05 GENERAL NOTES I,) ALL CONDOR 70 BE 1/2" EMT UNLESS OTHERWISE NOTED. 2.) ALL WIRE TO 8E 112 THHN/THWN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480V "A" PHASE (LEFT BUS IN PANEL) BLACK BROWN "B' PHASE (CENTER BUS IN PANEL) RED ORANGE "C PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHRE CRAY EQUIPMENT GROUND GREEN 4.) LARCE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL DE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK 10 SOURCE, INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAY. 6.) PERMANENTLY LABEL ALL RECEPTACLES. JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 7.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 8.) VERIFY ROTATION OF ALL 3 PHASE MOTORS. ONS UC ION 0 S >PROVIDE 1/2"C FROM JUNCTION BOX LOCATED ON THE SECURE SIDE OF THE DOOR TO CARD READER JUNCTION BOX. COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH SECURITY VENDOR. RECEIVED CITY OF TUKWILA 2 «PROVIDE 1/2" CONDUIT FROM JUNCTION BOX ON THE SECURE SIDE OF THE DOOR TO THE REQUEST TO THE REQUEST TO EXIT DEVICE AND ELECTRONIC STRIKE. COORDINATE EXACT LOCATIONS AND PATHWAY WITH SECURITY VENDOR. PROVIDE CONDUIT BACK TO SECURITY PANEL AT GRIDLINE D3. .PROVIDE PATHWAY AND ROUGH —IN FOR SECURITY DEVICES INSTALLED UNDER THIS PROJECT. COORDINATE EXACT LOCATIONS AND TERMINATION POINTS WITH SECURITY CONTRACTOR. JAN 1 4 2014 PERMIT CENTER 9-120 ASIC 100% CD ISSUE SUBTITLE SECOND FLOOR 208Y/120V POWER PLAN O KEY PLAN SCALE: NONE 8' 4' 0 4' 8' 16' SCALE: 1/8"=1'-0" CURRENT REVISION 131174-00 SYMBOL M O 0 O DATE 12.12.13 ENGINEER ED APPROVED APPROVED TITLE BOEING 9-120 AOE OFFICE MODERNIZATION ELECTRICAL MASTER BUILDING 9-120 COL. F—K/1-5 DEV. CENTER, WA SHEET 2E61 E* JOB NO. CRAP NO. 9-120-2E61 CONSTRUCTION NOTES LEGEND STA 2A7 -3 EF2A7 4HP 12BV SU 2A7-6/12c LCD 1.'� 'r�61II*PE ( OR 282-5/2a Ferilled R:III YLLI T • 2A7-4 1L2A7-61 2A7-5 5KVA 2-1/2"-4/4/0 MAIN ELEC2A7-" -6/14B,X M SW STAIR 2A7-4/ta,3b,5c, 7o,9b.11c 4/13a,15b 2A7-6/10,35.5c. 7a,9b,11c ., 2 7-4/250,27.29c HONE I 11M PHON Rj111 .-i-IIJ POE 1 27h •7 1 21b.23c t 5-p-v ":IItYiYYi Oil I� 11tNES71�!I ;:1 l3c REVISION 2A7-5 2c,1 Jb,18c 247-5/20, b,6c, 8o,10b 2A7- 4/2a.4b,6c, -8a,10b 2A7-4/190 BY APPROVED 2c.14a 2A7-5/7o,9b,11c, OPEN OFFICE 2A7-5/200, 2b,24c 5/26o,28b.3 0 0 n n �T 00 I i CT d ie P O min \P `/ OOM �I E2 R00 it0,21b.2 LC. g.,,:.,, i 250.2 •,29 ., r.�X4t�—, 1 h; FO 4 i 1 I D ` (np) �;� �,I, .� 25a �'"�,•• O 18ci ,J 6 �190,25/1}a,756.17c, OPEN (WO 111 OFFICE — 2E622�--(I'— 0,9�5'1 g0._,3D,5c. , 71 C7 0 0 75b 1 II 0 • °, /� hY 'Ff /' iiiYYi YYYYYYIII 7/� �C E� /21IIpEA KAI Air* r_ ivikir lid w „1IA I QI !ITCT_T !IL i ,, HPLoU R S .11 FCI "� 1 'V9• IT CPe c.:,cl 8 S��� NOV H�S j/32. PIEN ..f DATE 2A7-6/ SEM 2A7-4/ to,33b,35c 35c REASON 2E503 2A7- 5/25o, 31 o.33b.35c 2A7-4/140,166,18c a 2A7-6/2o.4b.6c AC204 4A 20.40OBV-16 CONDENSATE PUMP 120V-10 2E62 2E504 SECOND FLOOR 208Y/120V POWER PLAN 0 SCALE: 1/8" = 1'-0" BY APPROVED DATE ORIG BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-00 BRM CEI 12.12.13 REVIEWEDE OR N COMPEL 0 - NEC NFPA JAN 31 2014 9-120 ASIC 100% CD ISSUE ES' 4 ONII. YV WIN WO ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN COFFMAN E. SWEET SWEET [2:> JUNCTION BOXES FOR AV WITH CONDUIT BETWEEN BOXES AND CONDUIT FROM UPPER BOX TO ACCESSIBLE CEILING SPACE. COORDINATE BOX LOCATIONS WITH ARCHITECT PRIOR TO ROUGH -IN. REFER TO AV DRAWINGS FOR JUNCTION BOX AND CONDUIT SIZES AND LOCATIONS. PROVIDE CEILING MOUNTED RECEPTACLE FOR PROJECTOR. PROVIDE POWER CONNECTION AND BACKBOX FOR CONTROL PANEL (CP). COORDINATE WITH AV DRAWINGS FOR ADDITIONAL REQUIREMENTS AND LOCATIONS. PROVIDE RECEPTACLE FOR WALL MOUNTED MONITORS, PROVIDE TWO -GANG 31'4"D JUNCTION BOX WITH (1) 1Y2"C TO ACCESSIBLE CEILING SPACE FOR AV. COORDINATE BOX LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. E> PROVIDE RECEPTACLE FOR CONDENSATE PUMP. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR. © PROVIDE HORSE POWER RATED MANUAL MOTOR STARTER SNAP SWITCH TO SERVE MECHANICAL EQUIPMENT. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR. PROVIDE 120V POWER TO METERING CABINET AND CONTROLS CABINET. COORDINATE THE EXACT LOCATION OF METERING CABINET WITH BOEING AND THE LOCATION OF THE CONTROLS CABINET WITH THE CONTROLS CONTRACTOR. ® MOUNT RECEPTACLE ABOVE COUNTER. COORDINATE EXACT HEIGHT WITH ARCHITECT. MOUNT RECEPTACLE IN CREDENZA FOR AV EQUIPMENT. PROVIDE CONNECTION TO UNDER CABINET WATER HEATER. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR. PROVIDE CONDUIT BACK TO SECURITY PANEL IN DATA ROOM 22D6. PROVIDE PATHWAY AND ROUGH -IN FOR SECURITY DEVICES INSTALLED UNDER THIS PROJECT. COORDINATE EXACT LOCATIONS AND TERMINATION POINTS WITH SECURITY CONTRACTOR. HOME RUN CONDUITS TO BE 3/4"C MINIMUM. PROVIDE 1"C WHERE #10 AWG CONDUCTORS ARE SHOWN. INSTALL HILTI PUTTY PADS ON ALL IN WALL BACKBOXES LOCATED IN CONFERENCE ROOMS, PROJECT ROOMS AND ANY OTHER ENCLOSED SPACES WITH LCD MONITORS. PROVIDE 1/2"C FROM JUNCTION BOX LOCATED ON THE SECURE SIDE OF THE DOOR TO CARD READER JUNCTION BOX. COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH SECURITY VENDOR. ib PROVIDE 1/2" CONDUIT FROM JUNCTION BOX ON THE SECURE SIDE OF THE DOOR TO THE REQUEST TO THE REQUEST TO EXIT DEVICE AND ELECTRONIC STRIKE. COORDINATE EXACT LOCATIONS AND PATHWAY WITH SECURITY VENDOR. PROVIDE POWER CONNECTION AND SWITCH FOR MOTORIZED SHADES INTERFACE WITH AV SYSTEM. COORDINATE WITH AV CONTRACTOR FOR ADDITIONAL REQUIREMENTS, WALL MOUNTED LCD. TYPICAL FOR ALL PROJECT ROOMS, AND CONFERENCE ROOMS. [> PROVIDE CONNECTION TO GRAFIK EYE SCENE CONTROLLER. COORDINATE MOUNTING HEIGHT FOR EACH LCD RECEPTACLE WITH ARCHITECT PRIOR TO ROUGH -IN. I' REFER TO AV DRAWINGS FOR LOCATIONS AND SIZES OF JUNCTION BOXES FOR AV CABLING AS WELL AS CONDUIT BETWEEN BOXES AND 'UP TO CEILING SPACES. DATE 05.23.07 05.23.07 COORDINATE EXACT LOCATION WITH CONTROLS CONTRACTOR. SECOND FLOOR 208Y/120V POWER PLAN $N DUPLEX RECEPTACLE DOUBLE DUPLEX RECEPTACLE POKE THRU EQUIPMENT CONNECTION CEILING MOUNTED RECEPTACLE HORSE POWER RATED MANUAL STARTER SWITCH GFC!ft GROUND FAULT CIRCUIT INTERRUPTING RECEPTACLE CARD READER REQUEST TO EXIT DEVICE ELECTRIC DOOR STRIKE AV CONTROL PANEL AV LCD BACK BOX AV JUNCTION BOX IlLCD DUPLEX RECEPTACLE FOR LDC GENERAL NOTES 2. ALL CONDUIT TO BE 1/2" EMT UNLESS OTHERWISE NOTED. ALL WIRE TO BE #12 THHN/THWN UNLESS OTHERWISE NOTED. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480V 'A" PHASE (LEFT BUS IN PANEL) BLACK BROWN 'B" PHASE (CENTER BUS IN PANEL) RED ORANGE PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EOUIPMENT GROUND GREEN 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. 6. 7. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAY, PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION BOXES. SWITCHES, ETC., WRH CIRCUIT IDENTIFICATION. INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. B. VERIFY ROTATION OF ALL 3 PHASE MOTORS. 9. COORDINATE CONDUIT ROUTING AND JUNCTION BOX LOCATION WITH ARCHITECTURAL REFLECTION CEILING PLANS. CONDUITS 10 BE GROUPED TOGETHER AND ROUTED PARALLEL OR PERPENDICULAR TO BUILDING LINES. ALL EXPOSED CONDUIT SHALL BE PAINTED TO MATCH THE SPACE IT IS INSTALLED IN. RECEIVED CITY OF TUKWILA KEY PLAN SCALE: NONE 8' 4' 0 4' 8' 16' MIN MI SCALE: 1 /8"=1'-0" .COFFMAN NGINEERS 1601 Fifth Avenue, Suite 900 I Seattle, WA 96101 PN 200,623.07171 fax 2066146774 emm,,.n,eo,e LASTING .......i,,.u,i.w++4 CURRENT., REVISION SYMBOL DATE 31174-DO 0 RIG 12.12.13 NOINLLN CHECKED APPROVED APPROVED TITLE BOEING 9-120 ASIC OFFICE MODERNIZATION ELECTRICAL MASTER BUILDING 9-120 COL. A-F/5-9 DEV. CENTER, WA SKEET 2E62 E* JOB NO. 131174-00 COMP NO. Dwc NO. 09-120-2E62 noel, ,111 REVISION BY APPROVES DATE SYN. REVISION AU OMATIC VALVE POWER SUPPLY „.„...—DRINKING FDA AU OMATIC VALVE POWER SUPPLY SECOND FLOOR 208Y/120V POWER PLAN SCALE: 1/8" = 1'-0" BY APPROVED DATE ORIG BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-00 BRM CEI 12.12.13 SE STAIR 21J7 DN �BOE/N6® -_- .St/9.A11. Y�1 AC CE P TAB I L ITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE REVIEWED Oht WITS COMPLIANCE NFPA 70 - NEC JAN 31 2014 City of Tukwila BUILDING DIVISION DRAWN COFFMAN CNE CKED E. SWEET ENGINEER 'CRECHES APPROVED APPROVED DATE 05.23.07 05.23.07 LEGEND DUPLEX RECEPTACLE GFCI GROUND FAULT CIRCUS INTERRUPTER RECEPTACLE $ LINE VOLTAGE SWITCH GENERAL NOTES I. ALL CONDUIT TO BE 1/2" EMT UNLESS OTHERWISE NOTED. 2. 3. ALL WIRE TO BE #12 THHN/THWN UNLESS OTHERWISE NOTED. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUSS 600 VOLTS OR LESS. 120 208V 277/48DV "A" PHASE (LEFT BUS IN PANEL) BLACK BROWN "B' PHASE (CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE CRAY EQUIPMENT GROUND GREEN 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAY, 6. PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION BOXES. SWITCHES. ETC., WITH CIRCUIT IDENTIFICATION. 7. INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 8. VERIFY ROTATION OF ALL 3 PHASE MOTORS. REFERENCE DRAWINGS CONSTRUCTION NOTES PROVIDE CONNECTION TO 120:24V TRANSFORMER FOR FLUSH VALVES AND AUTOMATIC FAUCETS IN RESTROOM. PROVIDE ABOVE COUNTER RECEPTACLE. COORDINATE HEIGHT WITH ARCHITECTURAL ELEVATIONS SO RECEPTACLE IS 6" ABOVE BACKSPLASH. PROVIDE LINE VOLTAGE SWITCH TO DISCONNECT FLUSH VALVE POWER. COORDINATE EXACT SWITCH LOCATION WITH BOEING. RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER 9-120 ASIC 100% CD ISSUE SUBTITLE SECOND FLOOR 208Y/120V POWER PLAN TITLE BOEING 9-120 ASIC OFFICE MODERNIZATION ELECTRICAL MASTER BUILDING 9-120 COL. F-K/S-9 DEV. CENTER, WA 8' 4' 0 4' 8' 16' ---- MN In SCALE: 1 /8"=1'-0" ACOFFMAN NGINEERS 1801 Fifth Avenue, Suite BOO Seellle, WA8E1101 Po 286822A11111n20e.8212115 LASTING wool a.wiw..+p CURRENT REVISION 131174-DO 5""ASLORIG DATE 12.12.13 SHEET 2E63 E* JOB NO. DWG ND, 131174-00 09-120-2E63 COMP NO. .ter 19 NM LEGEND 1EATER, BALCONY rt."' eO\ s[ [so BOON BUS RUG e0WA1M mhmr Mw ker 0P2 TO LTG f01. IN e1IlMA1 /4 c VA 401 see-,m.mTa. to 1& m m> IM INSTANT WATER HEATER 7KW 3BB-2/138,156,17c 3/4"C. 4110, #10 ORD. Tux 100A 120/208V GE 'DH' BUSWAY SMOKE DETECTOR (6 TYP) (3)1P20A (21P20A E l)1P30A (1)3P30A L 3 CD .. > mcsee-i/ 3 I. n 1'C, 5#10,2ij8 d-3B8-1/21 1/2"C, 2112 BALCONY EMPTY (3)1P20A ](3)1P20A D (1)1P30A (1)1P20A (1)1P20A see-1/as SEE 9-120-3E60 I"C, EMPTY 3/4" #10 304/13,15,17 1"C, 4((12 304/18 as,AA?Ap - enc.Pa /IDl 1/1'f-M0 SYSTEM FURS, CONNECTION PLAN111 dOlr "OII CD RAMP'UP see-N 1 c-0po IwT mx[cRP SYSTEM FURS. CONNECTION /' SEE 9-120-3E60 DOWN ERMINAL ON ROOF EDGE ON ROOF EDGE 1Ze 1'C, DATA & COMM CABLES RUN ON CEILING OF 2nd FLOOR TO RANGE FACILITY. SEE DWG. I 09- I 20-2003-E33 REVIEWED FOR COMPLIANCE WITH iiii SPA 70 -NEC JAN 3 1 2014 City of Tukwila BUILDING DiVlSlnn� City of Tukwila BUILDING DIVISIC ° ICE 15A, 125V. 1 PHASE. DUPLEX RECEPTACLE 20A, 125V, 1 PHASE DUPLEX RECEPTACLE 15A, 125V, 1 PHASE DUPLEX RECEPTACLE (DEDICATED) 15A, 125V, 1 PHASE, DUPLEX RECEPTACLE DROP O 15A, 125V, 1 PHASE, 4-PLEX RECEPTACLE DROP ( 30A, 125V, 1 PHASE, TV4STLOCK RECEPTACLE • 15A, 125V, 1 PHASE, 4-PLEX RECEPTACLE ▪ 15A, 125V. 1 PHASE. 4-PLEX POWER POLE ® DATA POLE $ SINGLE POLE TOGGLE SWITCH 120/208V DISTRIBUTION PANEL A TRANSFORMER, CAPACITY, PHASE & VOLTAGE AS SHOWN ,,,O DISCONNECT SNITCH, NON -FUSED, XX AMPERES O MOTOR STARTER, MANUAL ▪ 115V MOTOR (SIZE AS NOTED) O 208 OR 230V MOTOR (SIZE AS NOTED) 30A, 120/208V. 3 PHASE 5 MIRE. ISO. GRD. RECEPTACLE, 10 HUBBLE OG281D GENERAL NOTES I.) ALL CONDUIT TO BE 1/2" EMT UNLESS OTHERWISE NOTED. 2.) ALL WIRE TO BE q12 THAN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR COOING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/2D8V 277/4804 "A" PHASE (LEFT BUS IN PANEL) BLACK BROWN "B' PHASE (CENTER BUS IN PANEL) RED ORANGE "C' PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EOUIPMENT GROUND GREEN 4.) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) ALL UNUSED CONDUIT AND WORE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAY, 6.) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3 7,) DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 8.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. CONSTRUCTION NOTES PROVIDE 120V CIRCUIT FOR CONNECTION TO AHU RECEPTACLES AND LIGHTING. CIRCUIT TO SPARE BREAKER IN PANEL 3D4 AND REDLINE ON RECORD DRAWINGS. RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER 9-120 ASIC 100% CD ISSUE KEY PLAN AEOFFMAN NGINEERS 1601 F 1111 Avenue, Gulls 000 I Seattle, WA 98101 P6 000.013.0717 I f..l00Sf..0me cenmanwm LASTING xuH v....Au.. 5VM RENSION BY APPROVED DATE REVISION BY APPROVED (ATE A ADT REPAIR & RELOC CONDUIT 10967128 VAVREK VAVREK 07.29.10 BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-00 BRM CEI 12.12.13 �BER7' W4s%//,. N� ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEP,. DATE DRAWN EDDIE P. DUARTE 'CATE 08.22.05 CPLCNED SUBTITLE 120/208V POWER TVGINIE& JOHN J. VAVREK TLCITED 08.22.05 APPROVED JOHN J. VAVREK 08.22.05 TITLE BOEING 9-120 ASIC OFFICE MODERNIZATION BUILDING 9-120.3 COL. A-F/5-9 DEV. CENTER, WA CURRENT REVISION 131174-00 SYMBOL B DATE 12.12.13 SHEET 3E62 E* JOB NO. COMP NO. ss nv;ll�GO APPROVED ELECTRICAL MASTER DWG NO. 9-120-3E62 LEGEND S'M REVISION BY LJ LJ L� APPROVED DATE SUM r-1 LJ ✓ rI LJ ✓ -1 L.J REVISION LT r1 LJ ri LJ CFCI 6b 16b EFRH7 I/3HP 120V-16 Li J THIRD FLOOR 208Y/120V POWER PLAN 0 SCALE: 1/8" = BY APPROVED DATE ORIG BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-00 BRM CEI 12.12.13 �BOE/A/G r L i J LJ LJ ri L ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN COFFMAN WCNED B. LJASWELL ENJMLLN C CKED DATE 12.12.13 12.12.13 APPROVED APPROVED REVIEWED W FOR COMPLIAN NFPA70 - NEC JAN 31 2014 City of Tukwila BUILDING DIVISION' CFCI ]i GROUND FAULT CIRCUIT INTERRUPTING RECEPTACLE WP$M WEATHER PROOF HORSE POWER RATED MANUAL STARTER SWITCH GENERAL NOTES ALL CONDUIT TO BE 1/2" EMT UNLESS OTHERWISE NOTED. 2. ALL WIRE TO BE /12 THHN/THWN UNLESS OTHERWISE NOTED. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/2OBV 277/4BOV "A" PHASE (LEFT BUS IN PANEL) BLACK BROWN 'B' PHASE (CENTER BUS IN PANEL) RED ORANGE "C' PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE CRAP EQUIPMENT GROUND GREEN 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG—IN CIRCUIT BREAKERS ON BUSWAY. 6. PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES. ETC., WITH CIRCUIT IDENTIFICATION. 7. INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 8. VERIFY ROTATION OF ALL 3 PHASE MOTORS. REFERENCE DRAWINGS CONSTRUCTION NOTES 1�PROVIDE NEW WEATHER PROOF WHILE IN USE, CFCI RECEPTACLE. 2 .PROVIDE WEATHER PROOF HORSE POWER RATED MANUAL MOTOR STARTER SNAP SWITCH TO SERVE MECHANICAL EQUIPMENT. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR. RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER 9-120 ASIC 100% CD ISSUE SUBTITLE THIRD FLOOR 208Y/120V POWER PLAN TITLE BOEING 9-120 ASIC OFFICE MODERNIZATION ELECTRICAL MASTER BUILDING 9-120 COL. F—K/5-9 ' DEN. CENTER, WA KEY PLAN SCALE: NONE 8' 4' 0 4' 8' 16' SCALE: 1/8"=1'-0" A&OFFMAN NGINEERS 1601 FIM Avenue, Tulle BOO I Seattle, WA 08101 ph 200 <20.0117 I fax 200.02.1.0770 wWmee.wm LASTING CURRENT RE'AStON SVMBDL DATE 131174-00 ORIG 12.12.13 SHEET 3E63 E* Joe NO. 131174-00 COMP NO. DWG NO. 09-12D-3E63 Nei, N111 LEGEND: SYM DEAD, ARAM/ DEAD, ABAND DEAD. ABANDONED DEAD. ABANDONED DEAD. ABANDONED REVISION B3-1144.46.413 DOER MOTOR Ransco AMA r 0 I BP = %BP mMr 3/CC B ThermolrOn N■ RODE .. . j 225MCA 210 200nso 83-1/13,15,I7 ■ � 2'R.AL-3a3 �4�e4�EITAR!`a po MiuI1Z--1 ill1_ ROOECO 111111 HY- ■ Y_ n ■1/Wp 1.1LA e ,e6 Thermotron 49 ROOEC0047 2DMCA rNM 0 Hy - AMMO i/3H- . Thermotro ROOEC0008 ELEV. MTR. 2-1/2'A1-31250 2 AL-(3)a4/O VA gg r B0 F4 B5/2,4,6 2'AL,3-4/0 BY 25MLA 2 1 F2"C,3 I SUB 6F4 83-1/20,22,4 83-1/14,IB. 8 i C,AIE 1 1/4'C,6-14 15A MCP B5/26.28,30 3/4"C,3-#10 OWN 3/4"C,611D APPROVED 14.16.15 2D,22,24 DATE .5 OOA iii ii, wM1 J■■_ '0 $,1121 45KVA AFAR. 480/120-208V 3PH60A III\, I FOR PNL A 111111'■Illfff 1/4"-412 & 8G 5KVA XFMR. 80/480Y/277V PH, 60HZ OR PNL B1 5001104696 83-1/2, .6 60/Nr 3/47C,3I8 3/4'C.3IB ISSO242000-3 ' 00E964 14ERIU180N-C 50011046961 I/!C 318b410 03-1/I 3,5 3/4'C.3I (NIU)g}-i__ SE 220000 3 CA IHERM2IRON-E 97011051125 1-1/2'C, EMPTY 3/4'C lIa /25,27,29 I"C,6#8 85/25.27.29 30 31.33.35 18 b A5 ID'_ SYM J1D 3/4'C,'to p REVISION 3/4'C, 3 BY 3/4'C, 3a8 UP 10 PNL 262 VIA 30KVA ADM ON C2 1- Pre .3l6,1#10G Il� PLAN 1/8- APPROVED BATE O 12510VA 3PH 60HZ 480/120-208V FOR PNL D2 3/4' X 30" , 5a500MCM ■111 I 2ooh7s FAN HP HP IN A IN ATTIC 110 30KVA 3PH 60HZ 480/120-208V FOR POLS 03 & 03-1 I II' III. 45KVA AFAR. 480/120-208 3PH, 60HZ FOR PNL D4 INSTALL (5) 440V DISCONNECTS 4617996 VAVREK VAVREK 04.04.07 0 ADD DISCONNECT SWITCH 10 DROP' 8034285 VAVREK VAVREK 11.18.08 INSTALL (3) DISCONNECT SWITCHES 57790800 VAVREK VAVREK 09.25.07 CAPITAL FOR THERMOTRONS 8-3 3339 ESBROOK VAVREK D3.25.09 INSTALL (3) DISCONNECT SWITCHES II 57790800 VAVREK VAVREK 10.09.07 INSTALL ROSLER VIBRATORY TUB WO5W732255 VAVREK VAVREK 03.09.12 INSTALL OVENS 8.5-2.5 57696401 ESBROOK VAVREK 12.11.07 T BOEING 9-120 AStC OFFICE MODERNIZATION 131174-00 BRM CEI 12.12.13 INSTALL OVEN B-2 57671601 ESBROOK VAVREK 05.22.08 3/A'C.SPO TO BP/47 cel___ArArzE,Afce 2"C, 3l4/0 MYERS MMXER 39-00810A EF #1E28 1/3 HP IN ATTIC iI/r06P7T I 2'C, 3#4/0 121 600*91 12 DIM 25KVA 480-240V-IPH SEE OWC, 1E60 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN M DITTMAR Korn m • a- EVIEWED FOhE}, , OMPLIANCE WIl NFPA70-NEC JAN 3 1 7f114 GENERA 1.) ALL CO 2.) ALL AIR 3.) THE FOL OBSERVE City of 'Tukwila BUILDING DIVISIONMP ENT CRO BUS IN PANEL) GREEN REN �CAAV 4.) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) ALL UNUSED CONDUIT AND WIRE 10 BE REMOIED BACK 70 SOURCE. INCLUDING PLUG-IN CWCUR BREAKERS ON BUSWAY. 6.) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. 7.) ONO LABEL ALL RECEPTACLES. JUNCTION BOXES. SWITCHES. ETC.. WITH CIRCUIT IDENTIFICATION. SEE 1E111 6.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 480 VOLT DROP, 3W. 4P, CROUSE HINDS, TYPE APR, XX AMP. 480 VOLT RECEPT., 3W, 4P, CROUSE HINDS, TYPE ARE, XX AMP. J-BOX 480/277V DISTRIBUTION PANEL TRANSFORMER, CAPACITY, PHASE & VOLTAGE AS SHOWN GROUND 480V 3 PHASE MOTOR MOTOR STARTER, MAGNETIC MOTOR STARTER, MAGNETIC W/ DISCONNECT SWITCH MOTOR STARTER, MANUAL DISCONNECT SNITCH. NON -FUSED, XX AMPERES MACHINE/EOUIPMENT NUMBER X, Y HORSEPOWER 480Y 3 PHASE FAN MOTOR,WITH HEATING COIL OMENTORY PUSHBUTTON SWITCH W/ PILOT LIGHT Could Aqua k- 5HP VFD Pump w/ Solo 5SLR-5H line Reactor 30KVA 3PH 60HZ 480/120-208V FOR PNL F3 Sc BUSWAY 70A Circuit Breaker Load Ode of X-fo 'DATE 10-17-94 O NOTES: Un TO BE 1/2" EMT UNLESS OTHERWISE NOTED. 70 BE 112 THAN UNLESS 07HERMSE NOTED. OWING COLOR CODING OF CONDUCTORS SHALL BE ON ALL CIRCUITS BOO VOLTS OR LESS. 12D/208V 277/ABOV 'A' PHASE CLEF BUS IN PANEL) BLACK BROWN 'B" PHASE (CENTER BUS IN PANEL) RED ORANGE DRAWINGS CONSTRUCTION NOTES: WALL MOUNT NEW TRANSFORMER ABOVE EXISTING PANELBOARD. COORDINATE INSTALLATION TIMING WITH THE DEMOLITION OF THE EXISTING CONDUITS THE PANEL TO THE 2ND AND 3RD FLOORS. REFER TO 1/5302 FOR SUPPORT DETAILS. PROVIDE NEW BUSDUCT CIRCUIT BREAKER AND ASSOCIATED WIRING TO THE NEW TRANSFORMER. COORDINATE CIRCUIT BREAKER NUMBER WITH BOEING AND RECORD ON RECORD DRAWINGS. PROVIDE WIRING AS SHOWN BETWEEN TRANSFORMER AND PANEL B1. PROVIDE A #BAWG GROUND FROM TRANSFORMER GROUND BAR TO BUILDING STEEL. ® RELOCATE EXISTING CONDUITS AND WIRING SERVING LIGHTS AS REQUIRED TO INSTALL NEW TRANSFORMER. RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER 9-120 ASIC 100% CD ISSUE SUBTITLE 480/277 VOLT POWER 1E112 1E111 1E113 Wal KEY PLAN ACOFFMAN NGINEERS 1801 Fifth Avenue, Sul.e 9001 Seattle, WA 08101 Rh 206.623A11711n 2136.624.3776 cartnu LAA116444 CUR ENT REVISION 131174-00 SYMBOL T 0 0 0 DATE 12.12.13 LNUINLLH JOHN J. VAVREK CHECKED JOHN J. VAVREK APPROVED NAREN MEHTA APPROVED 10-19-94 10-19-94 10-19-94 TITLE BOEING 9-120 ASIC OFFICE MODERNIZATION ELECTRICAL MASTER BUILDING 09-120 COL. A-F/1-5 DEV. CENTER, WA SHEET 1 E 110 E* JOB NO. COMP NO. OWE NO. 09-120-1E110 REVISION VIEW STATION STORAGE 121E1 CONFERENCE ROOM I 21A1 ASIC MANAGER OFFICE 25A1 I ASIC MANAGER OFFICE I 21A2 ASIC MANAGER OFFICE 126A2 I CONE ROOM DIRECTOR OFFICE 121A3 ASIC MANAGER OFFICE 24A3 COLLABORATION SPACE 21A4 PANTRY 22A1 NW STAIR 21B1 EXEC HOTEL 123A1 I EXEC HOTEL 24A1 HOTEL 122A2 P IJEC RO 24A2 HOTEL HALLWAY 2582 P•� EC RO 23A2 - OTHER ROOM I 22A3 FREIGHT ELEV. WM S.TELLITE �� ROOM I/ PROJECT RO0.- P 2 2,. JEC RO 24B2 OFFIC SSISTAN ASIC SUPERVISOR OFFICE 21B3 ROJECT ROOM 2383 I STORAGE 121C1 I JANITOR 22C2 I R 3 A 751NA XFMR 460:208V/120V 2 & 24MG ENTRY LOBBY 12382 I RECEPTION 12283 I IL It II It _I SECOND FLOOR 480Y/277V POWER PLAN 0 SCALE: 1/8" = 1'-0" R APPROVED DATE SYM REVISION BY LI APPRO./0 CLOSET 22C2 I DATE -I DC 123C VEST I'S ULE tags ECM O CONFERENCE I21C4I PH ONE A 9-120 RENOVATION J416054201-02 COFFMAN E. SWEET 07.12.07 RECORD DRAWING 41605420i-02 COFFMAN E. SWEET 05.15.08 BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-00 8RM CEI 12.12.13 3C4 PHONE 22C4 I LOBBY 122D2 I COFFEE BAR VIEW ROOM 1 121E2 I VIEW ROOM 2 122E2 CONFERENCE 124E2 I H VIEW ROOM 5 21D2 L E EWED FOR ICOMP?C H NFA0NEC JAN 31 2014 of r� r City Tukwila BUILDING DIVISION H [2:>•[>(2)3 1/2"-34300 MCM & 14IC Z)LAsrArs-,Arga BEBE'?u \ CONTINUED ON 2E112 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN COFFMAN EEU E.. SWEET DATE 05.23.07 05.23.07 $ COE1NTINUED11 ON 2 LEGEND GENERAL NOTES 1,) ALL CONDUIT 10 BE 1/2" EMT UNLESS OTHERWISE NOTED. 2.) ALL WIRE 10 BE 4I2 THHN/THWN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/4B0V "A" PHASE (LEFT BUS IN PANEL) BLACK BRDWN -Er PHASE (CENTER BUS IN PANEL) RED ORANGE C. PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4.) LARGE SIZE CONDUCTORS WHICH CO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAY. 6.) PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES. ETC., WITH CIRCUIT IDENTIFICATION. 7.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 8.) VERIFY ROTATION OF ALL 3 PHASE MOTORS. REFERENCE DRAWINGS CONSTRUCTION NOTES TOTAL LINEAR LENGTH OF CONDUCTORS BETWEEN SUB 75 ANO PANEL 2F2-1 TO BE A MINIMUM OF 295 FEET. PROVIDE NEW CONDUCTORS IN EXISTING CONDUIT TO SUB 25, EXISTING UNUSED CONDUITS TO REMAIN AS SPARE, REFER TO E4575 FOR ADDITIONAL INFORMATION. PROVIDE NEW CONDUIT AND CONDUCTORS AS SHOWN. REFER TO E4S75 FOR ADDITIONAL INFORMATION. ® PROVIDE NEW ELECTRICAL EQUIPMENT. REFER TO E4535 FOR DETAILS. RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER 9-120 ASIC 100% CD ISSUE SUBTITLE SECOND FLOOR 480Y1277V POWER PLAN KEY PLAN SCALE: NONE 8' 4' 0 4' 8' 16' E SCALE: 1/8"=1'-0" COFFMAN NGINEERS 1601 FAn Avenue. suite BOO 1 Seenle, WA MOT ph MU0AZMAi17 I Inf00.021.3MMS LASING a.....�.�.1+1..w« CURRENT REVISION 131174-00 SYMBOL B DATE 12.12.13 INHALER CHECKED APPROVED APPROVED TITLE BOEING 9-120 ASIC OFFICE MODERNIZATION ELECTRICAL MASTER BUILDING 9-120 COL. A-F/1-5 DEV. CENTER, WA SHEET 2E110 E* JOB NO. 16054201-02 COMP NO. DWG No. 09-120-2E110 SYM REVISION 1-I/4"-3+4 & 1b0 1F p-- (3)DI MIN I(LCP 2F2-3 ®2F2-3 2F2-2 2-1/2-3'4 0 & 11 G CONTINUED 2E110 R-YET'/4"-4 BY 225kVA T SERVIN" (FLOOR MCL*JTED) ODL ES ODL EO & IiETOR. E 45kVA TRANSFO SEA SEE VINE PANEL 2F2 3 (STACKED ABOVE) SFORMER INE CUSTOMER WORKSPACE APPAOAED DATE 5YM DATA CENTER VIEW ROOM 2 REHISION VIEW STATION STORAGE INNOVATION WORKSPACE X0 OFFICE WORK ROOM 3 DEVELOPER WORKSPACE CONFERENCE ROOM ROJECT ROOM PROJECT I ROOM INNOVATION WORKSPACE SECOND FLOOR 480Y/277V POWER PLAN N SCALE: 1 /8" = BY APPROVED DATE A 9-120 RENOVATION J116054201-D2 COFFMAN E. SWEET 07.12.07 BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-00 ORM CEI 12.12.13 9-120 - SPL LABS OCN 101 J116054201-02 COFFMAN P. )ONES 07.25.07 RECORD DRAWING J116054201-02 COFFMAN E. SWEET 05.15.08 RELOCATE LABS W526397 ESBROOK TAE 11.15.11 INSTALL 2 A/C UNITS 12472099 ESBROOK TAE 11.23.11 Q;LBOE/A/G® MECH. STORAGE 1 O REVIEWED FOB � CONFPA OC NECTH JAN 31 2014 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN COFFMAN City of Tukwila BUILDING DIVISION" DATE 05.23.07 'C11ELHLD E. SWEET 05.23.07 LEGEND Ms 480V PANEL m LIGHTING CONTROL PANEL fja ITEM 14FLA AMPS GENERAL NOTES 1.) ALL CONDUIT TO BE 1/2' EMT UNLESS OTHERWISE NOTED. 2.) ALL WIRE TO BE /12 THHN/THWN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480V "A" PHASE (LEFT BUS IN PANEL) BLACK BROWN 'E' PHASE (CENTER BUS IN PANEL) RED ORANGE "C' PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHRE GRAY EQUIPMENT GROUND GREEN 4.) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) ALL UNUSED CONCUR. AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAY. 8.) PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 7.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 8.) VERIFY ROTATION OF ALL 3 PHASE MOTORS. 9 > 09-120-5302 CONSTRUCTION NOTES INTERCEPT EXISTING CONDUIT AND PROVIDE A NEW 36%36"x8"D PULL BOX TO ACCOMMODATE FUTURE TIE BREAKER FEEDERS BETWEEN SUB 75 TO SUB 11. COORDINATE EXACT LOCATION WITH EXISTING STRUCTURE AND BOEING FACILITIES. PROVIDE NEW 45kVA TRANSFORMER STACKED ABOVE EXISTING TRANSFORMER. REFER TO E4S75 & 2/S302 FOR ADDITIONAL INFORMATION. REPLACE INTERIOR OF EXISTING PANEL BOARD. REFER TO E4S7 FOR DETAILS. ® PROVIDE NEW 1-1/2" CONCUR WITH 3/1/0AWG & 116AWG CONDUCTORS FROM PANEL 2F2-2 TO SERVE AHRC2. a> PROVIDE 3#3AWG & 1#BAWD CONDUCTORS IN EXISTING 1-1/4" CONDUIT FROM PANEL 2F2-2 TO SERVE AHRG4. RECEIVED CITY OF TUKWILA JAN 1 4 2014 8' 4PE�RMIT$.CENTER SCALE: 1 /8"=1-0" 9-120 ASIC 100% CD ISSUE SUBTITLE SECOND FLOOR 480Y/277V POWER PLAN 0 rz A 2E113 O KEY PLAN SCALE NONE &FOFFMAN NGINEERS 1601 Fifth Avenue, BuNe 80015e.We, WA9B101 ph 100.0234717 I. 206.6218170 coNnw:om tAsTIND CURRENT REVISION 131174-00 SYMBOL F DATE 12.12.13 ENGINEER 'CHECKED APPROVED APPROVED TITLE BOEING 9-120 ASIC OFFICE MODERNIZATION ELECTRICAL MASTER BUILDING 9-120 COL. F-K/1-5 DEV. CENTER, WA SHEET 2 E 111 JOB NO. ORG NO. COMP NO. 9-120-2E111 LEGEND SYM ASIC SUPERVISOR OFFICE 21A5 ASIC SUPERVISOR OFFICE 24A5 CONCEPT CENTER MANAGER 123A5 I CONCEPT CENTER MANAGER 121A6 PRINTER STATION 24 —1 2A7-2 SW STAIR I 21A7 I HONL ROOM ROO 23A7 22A7 CONFEREN ROOM 121A8 I REASON DOWN TO SUB35 FOR POWER METER CoNNRET10N NCLBSURE`7 VIDEO/ TELE CONFERENCE ROOM 23A8 I OPEN OFFICE 121C7 I CONCEPT CENTE SUPERVISOR 22A8 P'W CT OOM 22B6 1 PRO T R00 2106 6 MOBILE SOLDTI.CL PL R MANAGER ROOM MOBILE SOLUTIONS SUPERVISOR 21B8 BY 12288 I 12388 I ON TO PANEL C9 ON LEVEL 1 C NICAL •OM „ 80 10b 12C APPROVED DATE 5YM REVISION 0 OPEN OFFICE 12105 O J _ DATA >_ ROOM a J COLLABORATION SPACE 121C8 I CONTINUED ON 2E110 . (2)3 I/2"-38300 IICM & IQIG 2206 I SECOND FLOOR 480Y/277V POWER PLAN N SCALE: 1/8" = 1'-0" BY APPROVED DATE A 9-120 RENOVATION J#16054201-02 COFFMAN E. SWEET 07.12.07 B RECORD DRAWING J916054201-02 COFFMAN E. SWEET 05.15.08 C INSTALL PANEL 266 12370689 ESBROOK TAE 11.29.11 BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-00 BRM CEI 12.12.13 DAN 1/2"-39300 M & I91G (2)3 1/2 CONDUIT •NLY FOR FUTURE TIE SU 75 e:LlirAruzisfc DOWN TO SUB 75 ACCEPTABILITY TAGS DESIGN AND/OR SPECIFICATION 15 APPROVED APPROVED BY DEPT. DATE DRAWN COFFMAN HE PLIA CE WIITH I� FPA 70 - NEC JAN 31 2014 City of .Tukwila BUILDING DIVISION DATE 05.23.07 CHECKED E. SWEET 05.23.07 ITI TRANSFORMER 480V PANEL BOARD L=1 EQUIPMENT ENCLOSURE -- CONDUn STUB -OUT GENERAL NOTES 1.) ALL CONDUIT TO BE 1/2' EMT UNLESS OTHERWISE NOTED. 2.) ALL WIRE TO BE 112 THHN/THWN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BC OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480V TA" PHASE On BUS IN PANEL) BLACK BROWN `B" PHASE (CENTER BUS IN PANEL) RED ORANGE `C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4.) LARGE SIZE CONDUCTORS WHICH DO NOT HAW COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) ALL UNUSED CONDO AND WIRE 10 BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAY. 6.) PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION BOXES. SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 7.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 8.) VERIFY ROTATION OF ALL 3 PHASE MOTORS, CONSTRUCTION NOTES C> INTERCEPT EXISTING PULLBOX WITH NEW CONDUITS COMING FROM PANEL 2F2-1. 12> PROVIDE NEW CONDUCTORS IN EXISTING CONDUIT TO SUB 75. EXISTING UNUSED CONDUITS TO REMAIN AS SPARE. REFER TO E4S75 FOR ADDITIONAL INFORMATION. PROVIDE NEW CONDUIT AND CONDUCTORS AS SHOWN. REFER TO E4S75 FOR ADDITIONAL INFORMATION. PROVIDE NEW 480V PANEL. REFER TO DRAWING E4S35 FOR ADDITIONAL INFORMATION. TOTAL LINEAR LENGTH OF CONDUCTORS BETWEEN SUB 75 AND PANEL 2F2-1 TO BE A MINIMUM OF 295 FEET. PROVIDE CONDUIT SUPPORTS BETWEEN PULL BOX AND 2F2-I CAPABLE OF HANDLING (4)3-1/2" CONDUITS FOR FUTURE EXPANSION. RELOCATE EXISTING DISCONNECT AND ASSOCIATED EQUIPMENT SERVING HVAC UNIT TO NEW WALL. PROVIDE I/2"C BETWEEN PANEL 2A7-I AND METERING CABINET FOR Ci WIRING. PROVIDE I/2'C BETWEEN CT'S IN SUB 35 AND METERING CABINET FOR CT WIRING. 1h. PROVIDE 1/2"C BETWEEN ELECTRICAL ROOM AND A POINT OUTSIDE OF WORK AREA RE -PULL EXISTING POWER MONITORING CABLE FROM SUB Ti & SUB 75 COILED OUTSIDE OF WORK SPACE IN CONDUIT AND TERMINATE Al METER ENCLOSURE. PROVIDE NEW CABLE IF EXISTING IS NOT LONG ENOUGH TO REACH. PROVIDE NEW CABINET FOR HEAD END ENERGY METER. COORDINATE CABINET SIZE AND LOCATION WITH BOEING. PROVIDE NEW TRANSFORMER. REFER 10 E4S38 FOR DETAILS. RECEIVED CITY OF TUKWILA JAN 112014 KEY PLAN SCALE: NONE PERMIT CENTER 8' 4' 0 4. 8' 16' 9-120 ASIC 100% CD ISSUE SUBTITLE SECOND FLOOR 480Y/277V POWER PLAN SCALE: 1/8"=1'-0" 4COFFMAN NGINEERS 1501 FISM Avenue, Sulte 000 I Seattle, WA 08101 pH 000.00GAT1T 11.. 106.014.MTIS certm. LASTING CURRENT REVISION SYMBOL 131174-00 D DATE 12.12.13 4 1 4 4 LNWNLLN CHECKED APPROVED APPROVED TITLE BOEING 9-120 ASIC OFFICE MODERNIZATION ELECTRICAL MASTER BUILDING 9-120 COL. A-F/5-9 DEV. CENTER, WA SHEET 2E112 E* JOB NO. COMP NO. 16054201-02 DWG NO. 09-120-2E112 LEGEND SYM REVISION BY APPROVED DATE SYM REVISION SECOND FLOOR 480Y/277V POWER PLAN 0 SCALE: 1/8" = 1'-0" BY APPROVED DATE URIC BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-00 BRM CEI 12.12.13 BOE/A/G® ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN COFFMAN REVIEWED F( COMPLIANCE WI NFPA 70 - NEC JAN 3 1 'nik City of Tukwila BUILDING DIVI IOft -DATE 05.23.07 LHEL'kLU E. SWEET 05.23.D7 GENERAL NOTES 1. ALL CONDUIT TO BE 1/2" EMT UNLESS OTHERWISE NOTED. 2, ALL WIRE TO BE '12 1HHN/THWN UNLESS OTHERWISE NOTED. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480V "A" PHASE (LEFT BUS IN PANEL) BLACK BROWN "B PHASE (CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. ALL UNUSED CONDUIT AND WIRE 10 BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAY. 6. PERMANENTLY LABEL ALL RECEPTACLES. JUNCTION BOXES. SWITCHES, ETC.. WITH CIRCUIT IDENTIFICATION. 7. INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 8. VERIFY ROTATION OF ALL 3 PHASE MOTORS. REFERENCE DRAWINGS CONSTRUCTION NOTES RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER FOR REFERENCE ONLY FACILITY DESIGN BY DATE SUBTITLE SECOND FLOOR 480Y1277V POWER PLAN 2E110 2E111 2E112 KEY PLAN SCALE: NONE 2E113 A 0 4' 8' 16' SCALE: 1/8u=1'-0" g fOFFMAN NGINEERS 1601 FIM Avenue, Suns 900 I Seattle. WA98101 pN 1G6819A719 I feu 100.e14.9116 LAIen P LAanNo CURRENT REVISION 131174-0D 5YAR°LORIG DATE 12.12.13 LNOINLLH CHECKED APPROVED APPROVED TITLE BOEING 9-120 ASIC OFFICE MODERNIZATION BUILDING 9-120 ELECTRICAL MASTER COL. F-K/5-9 DEV. CENTER. WA SHEET 2E113 E* JOB NO. 131174-00 COUP NO. DWG NO. 09-120-2E113 LEGEND SYM REVISION HOIST CONTROLLER —UP 10 HOIST ON ROOF SEE 109-120-20O4-E50 BY APPROVED 3/4"C, 1'12 GATE 5YM 1'C. 314 m NV 3/4'C, 10 {'7 480V. 3PH, 3W BUSWAY 35F5-166 REMSION 3/4'C, 1110 30A NA 3/4"C, #10 30A AHU 20 3/4"C, #12 1-1/4'C, 3112 PLAN 3/4"C, 410 SCALE: 1/8" = 1'-0" APPROVED DAZE A BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-DO BRM CEI 12.12.13 60/50 3DRV . 3 H 460 120-2P06V —1"C, 3#)6 460/480450 3-27EV PH 4W 30NVp, 0-23 P0H AV4W 480/I DN STAIR #5 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN EDDIE P. DUARTE T •TE 08.22.05 O REVIEWED FOR LIANCE WITH N PA 70 - NEC JAN 3 1 2014 City of Tukwila BUILDING DIVISION O CHECKED O ® 480 VOLT DROP-3-WIRE, 4-POLE CROUSE • HINDS TYPE APR, XX APMERES. pi' 480 VOLT RECEPT., 3-WRE, 4-POLE, CROUSE HINDS, TYPE ARE, XX AMPERES. • J-BOX ® 480/277V DISTRIBUTION PANEL E] TRANSFORMER, CAPACITY, PHASE & VOLTAGE AS SHOWN GROUND 480V 3 PHASE MOTOR ® MOTOR STARTER, MAGNETIC 3e MOTOR STARTER, MAGNETIC W/ DISCONNECT SVITCH ® MOTOR STARTER, MANUAL '''CO DISCONNECT SNMTCH, NON -FUSED, XX AMPERES ® MACHINE/EQUIPMENT NUMBER X, A HORSEPOWER O GENERAL NOTES 1.) ALL CONDUIT TO BE 1/2" EMT UNLESS OTHERWISE NOTED. 2.) ALL WIRE 10 BE 112 THHN/THVM UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/20BV 277/480V "A" PHASE (LEFT BUS IN PANEL) BLACK BROWN "3" PHASE (CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BITS IN PAN11) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4.) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) ALL UNUSED CONDUIT AND WIRE 10 BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAY. 6.) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3 7.) PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION BOXES. SWITCHES. ETC., WITH CIRCUIT IDENTIFICATION. a) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 9.) VERIFY ROTATION OF ALL 3 PHASE MOTORS. CONSTRUCTION NOTES I FLOOR MOUNT NEW TRANSFORMER NEXT TO EXISTING PANEL BOARD. PROVIDE NEW BUS DUCT CIRCUIT BREAKER AND ASSOCIATED WIRING TO THE NEW TRANSFORMER. COORDINATE CIRCUIT BREAKER NUMBER WITH BOEING AND RECORD ON RECORD DRAWINGS. i> PROVIDE WIRING AS SHOWN BETWEEN TRANSFORMER AND PANEL 3C-1. PROVIDE A #8AWG GROUND FROM TRANSFORMER GROUND BAR TO BUILDING STEEL. RECEIVED CITY OF TUKWIL JAN 1 4 2014 PERMIT CENTER 9-120 ASIC 100% CD ISSUE SUBTITLE 480Y/277V POWER PLAN KEY PLAN .COFFMAN NGINEERS 1601 FAA Avenue, Sulfa 8001 Beat le, WA 98101 Pe 206.626.0711 I few 206824.6775 eeilman.ean LASTING CURRENT REVISION 131174-00 SYMBOL A DATE 12.12.13 ENGINEER CHECKED APPROVED APPROVED TrtLE BOEING 9-120 ASIC OFFICE MODERNIZATION ELECTRICAL MASTER BUILDING 9-120.3 COL. A-F/1-5 DEV. CENTER, WA SHEET 3 E 110 E* JOB NO. COMP ND. DWG NO. 9-120-3E110 LEGEND: 5vu 30KVA, 3PH, 4W 480V-120/208V 1'C, 316 -' �DOAD ENDED CD 1/2'C, 3/12J 300. 240V, 1PH 50/20 510,4154.90 4BR4810)/240V UP TO ROOF A/C UNIT �� 0 SEE 109-120-20D4-E51. �Q ALSO SEE SK/33V092282-E1 2'C, 414/D 87 r 187E 115 3B6 01 3/4 C, 3/1D-' a-277/480V WESTING HOUSE STANDARD PLUG-IN BUSWAY 1122 DO 10KW STRIP HEATER—." 3 TON A/C UNIT 9.5 RA Av 7/4"0, 318' 10 1,1 FLOOR, COL. C3 15KVA 1PH 480V/240V MM. /118 C, 316 y FAN 11 FAN 12 C. 4/8 m DEAD ENDED 3/4C. 411D FIRE CONT. PNL HVAC UNIT) 1.3 KW COMBINATION MOTOR STARTER WITH PUSHBUTTON ON/OFF CONTROL 3/4 HP WATER PUMP FOR VMS EOUIPMENT REVISION 386/26 2B,30 CD B 314 450A 3PH. 4W, I 4 45KVA, 3PH, 4W, 4EICIV 4AOY/277V 110 1-1/4"C, 4/4 & 118D� /4C, 3/8 63 314 UEBERT UNIT 30.5 FLA H- 3/4C. 3/1 /1 1-1/4'RSC. 3/1 UNDER CONCRETE ROOF THE. 10 TRAILER LAB SEE 109-120-2003-E53. -1-1/4-RSC. 341 251ryA 1PH 480/240V 3/4-C. 2/8 45KVA 3PH, 4W 480V-120 208V ., 318 ■ 81 // APPROVED DATE REVISION PLAN 1 /8" = 1'- 0" BY APPROVED DATE A DDT REPAIR AND RELOCATE CONDUITS 10967128 VAVREK VAVREK 07,29.10 BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-DO BRM CEI 12.12.13 2F2-2/13o.15b,17c 1-1/4-C - 3/3 & 118G 3 C, 4/4/0 RUN ALONE 2nd FLOOR CEILING TO MILLIMETER RADAR R.ANCE SEE 1D9-120-2003-E53. REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JAN 3 1 2014 City of Tukwila BUILDING DIVISI N �BOE/N6® ''!f 01:1_1tlVal Arlo MD ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED UT DEPT. DATE DRAWN E. DUARTE DATE 09/06/06 480 VOLT DROP-3-WIRE, 4-POLE CROUSE HINDS TYPE APR, XX APPERES. 4, 480 VOL1 RECEPT., 3-WIRE, 4-POLE, CROUSE HINDS, TYPE ARE, XX AMPERES. CD J-BOX ® 480/277V DISTRIBUTION PANEL Ep TRANSFORMER, CAPACITY. PHASE & VOLTAGE AS SHOWN GROUND O 480V 3 PHASE MOTOR ® MOTOR STARTER, MAGNETIC SY MOTOR STARTER, MAGNETIC WI DISCONNECT SWITCH ® MOTOR STARTER, MANUAL DISCONNECT SNITCH, NON -FUSED, XX AMPERES e MACHINE/EOUIPMENT NUMBER X, Y HORSEPOWER VFD VARIABLE FREQUENCY DRIVE GENERAL NOTES: 1.) ALL CONDUIT TO BE 1/2" EMT UNLESS OTHERWISE NOTED. 2.) ALL WIRE TO BE /12 THHN/THIN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480V "A' PHASE (LEFT BUS IN PANEL) BLACK BROWN "B" PHASE (CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4.) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAY. 6.) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3 7.) PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 8.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 9.) VERIFY ROTATION OF ALL 3 PHASE MOTORS. REFERENCE DRAWINGS 1T0 >09-120-5302 CONSTRUCTION NOTES: WALL MOUNT NEW TRANSFORMER ABOVE EXISTING. REFER TO 2/S302 FOR SUPPORT DETAIL. PROVIDE NEW BUS DUCT CIRCUIT BREAKER AND ASSOCIATED WIRING TO THE NEW TRANSFORMER. COORDINATE CIRCUIT BREAKER NUMBER WITH BOEING AND RECORD ON RECORD DRAWINGS. PROVIDE WIRING AS SHOWN BETWEEN TRANSFORMER AND PANEL 3C-1. PROVIDE A I8AWG GROUND FROM TRANSFORMER GROUND BAR TO BUILDING STEEL. PROVIDE STAINLESS STEEL NEMA 4X ENCLOSURE FOR WIRE SPLICES TO AHU FUSED DISCONNECTS. NOT USED. FUSED DISCONNECT AND VFD PROVIDED BY MECHANICAL CONTRACTOR INSTALLED BY ELECTRICAL CONTRACTOR. O O 3E110 RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER 9-120 ASIC 100% CD ISSUE SUBTITLE 480 VOLT POWER ENGINEER JOHN J. VAVREK 'CHICOED APPROVED JOHN J. VAVREK APPROVED 09/O6/05 09/D6/05 WILE BOEING 9-120 ASIC OFFICE MODERNIZATION ELECTRICAL MASTER BUILDING 9-120.3 COL. X—X/X—X DEV. CENTER, WA KEY PLAN 3E111 3E113 OFFMAN NGINEERS 1601 Fifth Avenue, Bullk, BOO I Seattle, WA 88101 PD 0A0.e00,0117 far 004A24.01T0 ceMmcnco CURRENT REVISION 131174-00 SYMBOL B DATE 12.12.13 SHEET 3E112 E* JOB NO. COMP NO. DAC NO. 9-120-3E112 CEILING MOUNTED FLOOR MOUNTED FR MLOOOUNTED REVISION h•wil,�a FEREN OM Am V.18 SIL• OFFIC. 26A2 IRE OFF1iE 21A LCD - — (TIP) COLLABORATION SPACE PANTRY 22A1 r T L_J RYC HOTEL LOTTE ROOM 9 > HALL FREIGHT ELEV. SATLILLIIT ROOM NW STAIR SD CD U LCD TAU CEPTION (TIP) STORAGE SECOND FLOOR TELECOMMUNICATIONS PLAN 0 SCALE: 1/8" = 1'-0" B7 APPROVED DALE SYM REASON Br APPROVED JANITOR 041E CLOSET A 9-120 RENOVATION J916054201-02 COFFMAN E. SWEET 07,12.07 BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-00 BRM CEI 12.12.13 9-120 RENOVATION - ASI 904 J#16054201-02 COFFMAN E. SWEET 08.03.07 9-120 RENOVATION - ASI #05 J916054201-02 COFFMAN E. SWEET 08.29.07 9-120 RENOVATION - RFI 9058 J416054201-02 COFFMAN E. SWEET 10.03.07 RECORD DRAWING J916054201-02 COFFMAN E. SWEET D5.15.08 LE VIEW 12 CABLE TRAY ROOM 1 +11' 6" AFF I 21F9 1B" CABLE TRAY 411E-6" AFF LOBBY 122D2 I SECURITY PAIGLQFFEE BAR E n wcc, MEN'S „ii„L,r1 E I" C. VIEW STATION STORAGE CONFERENCE I 24E2 VIEW ROOM 2 122E2 I r CE rCEILING MOUNTED LEGEND SZ DATA OUTLET Z TELEPHONE OUTLET 8 POKE-THRU TELECOMMUNICATIONS CONNECTION. REFERENCE DRAWINGS REVIEWED .FOIE COMPLIANCE 70NECTh NF F✓1 ROOM 5 +11 -6" AFF r' LI NNT 70 BIECAL)TRAV_ VIEW 12" CABLE TRA 12102 FIRE RATED SLEEVES NOMINAL 4"x4"x 4'L EZ PATH SERIE• 44 OR APPROVED EQUAL I I CR,RENCE �BOE/A/G AA PENNI, ft are. ig I ACCEPTABILITY THIS DESIGN AND/DR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN COFFMAN LHLSWEV E. SWEET JAN 31 2014 City Tukwila TT kwila BUILDING DIVISION_ DATE 05.23.07 05.23.07 PROVIDE DATA BELOW TABLE. ROUTE CABLING VIA FLOOR MOUNTED RACEWAY. REFER TO 2E60 FOR DETAILS. DATA PLATE MOUNTED IN UNISTRUT STRUCTURE. ROUTE DATA CABLING DOWN INSIDE UNISTRUT STRUCTURE TO LCD, GENERAL NOTES 1.) ALL CONDUIT TO BE 1/2" EMT UNLESS OTHERWISE NOTED. 2.) ALL WIRE TO BE 912 THHN/THWN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480V 'A" PHASE (LEFT BUS IN PANEL) BLACK BROWN PHASE (CENTER BUS IN PANEL) RED ORANGE PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EOUIPMENT GROUND GREEN 4,) LARGE SIZE CONDUCTORS WHICH 00 NOT HAVE COLORED .JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCLET BREAKERS ON BUSWAY, 6.) PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES. ❑C., WITH CIRCUIT IDENTIFICATION. 7.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 0 •T L9 UDDER TYPE CABLE TRAY, 12•W x 4"D x LENGTH AS REQUIRED. IA.) ELECTRICAL CONTRACTOR TO PROVIDE PATHWAY, BACK BOXES AND ROUGH -IN FOR TELECOMMUNICATIONS. CABLING AND EOUIPMENT BY NETVERSENT, COORDINATE ALL TELECOMMUNICATION LOCATIONS WITH NETVERSANT PRIOR TO ROUGH -IN. CONSTRUCTION NOTES PROVIDE DATA OUTLET FOR WALL MOUNTED MONITORS. COORDINATE MOUNTING HEIGHT AND LOCATIONS WITH LCD. PROVIDE CEILING MOUNTED DATA OUTLET FOR PROJECTOR. PROVIDE NEW CABLE TRAY. COORDINATE CABLE TRAY LAYOUT AND ROUTING WITH NETVERSANT PRIOR TO INSTALLATION. PROVIDE 1Y4" C. FROM SECOND FLOOR ACCESSIBLE TO RECEPTION STATION VIA FIRST FLOOR. STUB CONDUIT UP INTO A FURNITURE MOUNTED BACKBOX FOR DATA. PROVIDE (4) TELECOM MUD -RINGS EACH WITH (1) 1" C. TO ACCESSIBLE CEILING SPACE. ALIGN HORIZONTALLY BELOW POWER OUTLETS. © PROVIDE DATA OUTLETS FOR WALL MOUNTED MONITORS. COORDINATE HEIGHT AND LOCATIONS WITH LCD. TYPICAL FOR ALL PROJECT ROOMS, HOTEL ROOMS AND CONFERENCE ROOMS. INSTALL TELECOMMUNICATION DEVICES IN A BACK BOXES WRAPPED WITH HILTI PUTTY PADS FOR ALL TELECOMMUNICATION DEVICES LOCATED IN CONFERENCE ROOMS, PROJECT ROOMS AND ANY OTHER ENCLOSED SPACES WITH LCD MONITORS. ® MOUNT DATA OUTLET IN CREDENZA FOR AV EQUIPMENT. PROVIDE LOU" C. FROM SECOND FLOOR CEILING SPACE TO POKE-THRU BELOW TABLE. II RELOCATE EXISTING DEVICE TO NEW LOCATION SHOWN. RECEIVED CITY OF TUKWILA JAN 112014 PERMIT CENTER 9-120 ASIC 100% CD ISSUE SVBIBLE SECOND FLOOR TELECOMMUNICATIONS PLAN 0 0 0 j2E360/ 2E361 j 2E362 2E363 KEY PLAN SCALE: NONE 0 8' 4' 0 4' 8' 16' SCALE: 1/8"=1'-0" ACOFFMAN NGINEERS 1601 Fifth Avenue. Suite 10O01 Seattle, WA 68101 pM1 7➢6m1.0717 lea MOD14]T6 cul7manwn Losnm ,...�mt... w.w.. CURRENT REVISION 131174-00 SWABOL E DATE 12.12.13 NDINEER CHECKED APPROVED APPROVED TITLE BOEING 9-120 ASIC OFFICE MODERNIZATION ELECTRICAL MASTER BUILDING 9-120 COL. A-F/1-5 DEV. CENTER, WA SHEET 2E360 E* JOB NO. 16054201-02 COMP ND. DWG NO. 09-120-2E360 We I "all LEGEND GENERAL NOTES SYM PRINTER STATION MAIN ELEC ° ROOM REVISION LCD �P) 14121 WI I�I I�I I�I III III CEILING MOUNTED BY APPROVED DATE 2E360 2E503 OPEN OFFICE 2105 I --I❑PRO ROO� E106 Ir4.". II'�1' WILILTSC !r PLU1JLR Pr6 p 4 MAN ER ROOM oLT MOBILE IBB _ I 23B8 L�J SUP' �b 5YM MECHANICAL ROOM REVISION SCALE: 1/8" = 1'-0" O a 0 Il DATA ROOM 22D6 I I 9 > (4) FIRE RATED LEEVES NOMINAL 4"x4"x14"L EZ PATH SERIES 44 OR PROVED EQUAL (Tv-1—x x x x SECOND FLOOR TELECOMMUNI ATIONS PLAN 0 BY APPROVED DATE ORIC BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-DO RPM CEI 12,12.13 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN COFFMAN HECKLD B. MAXWELL ANAINLER CHECKED APPROVED APPROVED TATE 11.21.13 11.21.13 SZ DATA OUTLET i TELEPHONE OUTLET S POKE-THRU TELECOMMUNICATIONS CONNECTION. ® PEDESTAL DATA OUTLET LCD SZ DATA OUTLET FOR LCD REVIEWED WITH COMPLIANCEFA 70 - NEC City of Tukwila JAN 3 1 2014 BUILDING DIVISION: CONSTRUCTION NOTES 1. ALL CONDUIT TO BE 1/2" EAT UNLESS OTHERWISE NOTED. 2. ALL WIRE TO BE 112 THHN/THWN UNLESS OTHERWISE NOTED. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS B00 VOLTS OR LESS. 190/208V 277/480V 'A" PHASE (LEFT BUS IN PANEL) BLACK BROWN -B" PHASE (CENTER BUS IN PANEL) RED ORANGE -C PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAY, 6. PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION BOXES. SWITCHES. ETC., WITH CIRCUIT IDENTIFICATION. 7. INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 8. VERIFY ROTATION OF ALL 3 PHASE MOTORS. I> LADDER TYPE CABLE TRAY, 12'W x 4'D x LENGTH AS REQUIRED. W. ELECTRICAL CONTRACTOR TO PROVIDE PATHWAY. BACK BOXES AND ROUGH -IN FOR TELECOMMUNICATIONS. CABLING AND EQUIPMENT BY NETVERSENT. COORDINATE ALL TELECOMMUNICATION LOCATIONS WITH NETVERSANT PRIOR TO ROUGH -IN. REFERENCE DRAWINGS PROVIDE DATA OUTLET FOR WALL MOUNTED MONITORS. COORDINATE MOUNTING HEIGHT AND LOCATIONS. PROVIDE CEILING MOUNTED DATA OUTLET FOR PROJECTOR. PROVIDE (4) TELECOM MUD -RINGS EACH WITH (1) 1" C. TO ACCESSIBLE CEILING SPACE. ALIGN HORIZONTALLY BELOW POWER OUTLETS. PROVIDE DATA OUTLET FOR WALL MOUNTED MONITORS. COORDINATE HEIGHT AND LOCATIONS WITH LCD. TYPICAL FOR ALL PROJECT ROOMS AND CONFERENCE ROOMS. INSTALL TELECOMMUNICATION DEVICES IN A BACK BOXES WRAPPED WITH HILTI PUTTY PADS FOR ALL TELECOMMUNICATION DEVICES LOCATED IN CONFERENCE ROOMS, PROJECT ROOMS AND ANY OTHER ENCLOSED SPACES WITH LCD MONITORS. PROVIDE DATA OUTLET MOUNTED ABOVE COUNTER. COORDINATE EXACT LOCATION WITH ARCHITECT. PROVIDE PULL BOX MOUNTED IN WALL FOR TELECOMMUNICATIONS CABLING ROUTED AROUND CORNER INTO PARTIAL HEIGHT WALL. PROVIDE DATA OUTLET MOUNTED IN AV CABINET. 9-120 ASIC 100% CD ISSUE SUBIITLE RILE SECOND FLOOR TELECOMMUNICATIONS PLAN BOEING 9-120 ASIC OFFICE MODERNIZATION ELECTRICAL MASTER BUILDING 9-120 COL. A-F/5-9 DEV. CENTER, WA RECEIVED CITY OF TUKWILA JAN 1 1 2014 KEY PLAN SCALE: NONE 8' 4' 0 4' 8' 16' —� SCALE: 1/8"=1-0" ffOFFMAN NGINEERS 1801 Fifth Avenue, Suite 900I See.e, WA 90101 Ph 200.023A1111 Ins 204.024.3713 col! men com LASTING ...en..., n..., re.* CURRENT REVISION 131174-00 SYMB°LO R I C DATE 12.12.13 SHEET 2E362 E* .TDB NO. 131174-00 COMP NO. OWL NO 09-120-2E362 LOCATED IN ELECTRICAL ROOM SYM RELAY PER LIGHTING LIGHTING CONTROL CONTROL PANEL PANEL LCP-202-3 SCHEDULE ---,`^ 277V-10 LIGHTING CIRCUIT 120V-1N CONTROL S CIRCUIT i VIEW ROOM/FLIR ROOM LIGHTING (AS OCCURS) LUTRON HP 2 DIMMING MODULE (NOTE 1) LOCATED IN VIEW ❑ ❑ ❑ ROOM/FLIR ❑ ❑ U ❑ ROOM ,— 2-BUTTON LV WALL {L LUTRON MA-600 SWITCH (TYP) MASTER DIMMING WALL SWITCH LOCATED IN AOMIN ROOM 0 LLUTRON MA-R-600 REMOTE DIMMING WALL SWITCH NOTE 1: ONE LUTRON HP2 DIMMING MODULE REQUIRED FOR EACH ROOM. SWITCHED FLUORESCENT ELEVATOR DISCONNECT (BUSSMAN POWER MODULE SWITCH) (PER PLAN) (PER DIMMED PLAAN)ORESCENT = VIEW ROOM LIGHTING CONTROL DIAGRAM (TYPICAL) E5001 SCALE: NONE - NEMA L6-20R RECEPTACLE (TYP) 2ND HO E O FROM BOTTOM 0 0 RACK REAR NEMA L6-2GR RECEPTACLE 0 0 10o RACK SIDE DCN ROOM RACK RECEPTACLE MOUNTING DETAIL E501 SCALE: NONE REVISION 61 APPROVED DATE SYM REVISION ELEVATOR CONTROLLER FIRE ALARM DEVICE 60A BUS PLUG ELEVATOR CAB OATS INTERFACE MODULE WITH NOV FUSES CONNECT TO EXISTING 480Y/27N BUSWAY 1%". 3(j6 & 1 fi10 G LOCATED IN ELEVATOR LOBBY ON EACH FLOOR SERVED --'E Yx", 56fi18 TO ADT PANEL LOCATED 1 AT COLUMN K/3 ON THE FIRST FLOOR LOCATED AT TOP OF ELEVATOR SHAFT ELEVATOR MACHINE ROOM E5001 SCALE: 1/4" = 1'-0" Yx" x 4" x 10" COPPER GROUND BAR WITH WALL MOUNTING BRACKETS AND INSULATORS CP1110622-010 PROV DE EXOTHERMIC BOND (CADWELD OR EQUAL) TO GROUND BAR 0 0 o 2 0 0 0 0 oo a 0 O O O o— PROVIDE ONE (1) #6 AWG STRANDED GREEN GROUND TO EACH EOUIPMENT RACK PROVIDE EXOTHERMIC BOND (CADWELD OR EQUAL) TO GROUND BAR NOTE: NOT ALL PARTS AND PART NUMBERS ARE SHOWN. THE CONTRACTOR IS RESPONSIBLE FOR A COMPLETE WORKING INSTALLATION INCLUDING, MISCELLANEOUS APPURTENANCES. GROUND BUS BAR ASSEMBLY E5001 SCALE: NONE BY APPROVED DATE ORG 9-120 RENOVATION Ji16054201-02 COFFMAN E. SWEET 07.12.07 A BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-00 BRM CEI 12.12.13 ELEVATOR POWER SOURCE I N/P SHUNT TRIP WITH MECH. INTERLOCKED AUX. CLEARING CONTACT PROVIDE #2 STRANDED GREEN GROUND CONDUCTOR IN 1/2" EMT TO MAIN SERVICE GROUND BUS. COMPLY WITH ANSI - J -STD- 607-A- 2002 REQUIREMENTS gi_4749E7Arc. BUSSMANN POWER MODULE SWITCH. REFER TO NOTE 1 1 120V IN/PI -If PILOT LICHT � — FIRE ALARM INTERFACE RELAY IN/PI II R1 R2A T R2B CLEARING CONTACT NOTE 5 SHUNT TRIP _ R3A R38 NOTE 6 NOTES. 1. PROVIDE BUSSMANN POWER NODULE SWITCH (MODEL PS) WITH CONTROL POWER TRANSFORMER. GREEN PILOT LIGHT, KEY OPERATED TEST SWITCH, AUXILLARY (AUX.) CONTACTS AND FIRE ALARM INTERFACE RELAY. SWITCH RATING AND FUSE SIZE SHALL BE AS INDICATED ON THE DRAWINGS. 2. PROVIDE A 135' HEAT DETECTOR LOCATED WITHIN 18" OF EACH SPRINKLER HEAD IN THE ELEVATOR HOISTWAY. 3. PROVIDE A 135' HEAT DETECTOR LOCATED WITHIN 18" OF EACH SPRINKLER HEAD IN THE ELEVATOR MACHINE ROOM. 4. NEAT DETECTORS SHALL BE AN AUXILLARY FUNCTION OF THE ELEVATOR EQUIPMENT AND SHALL BE IDENTIFIED WITH A NAMEPLATE THAT READS: ELEVATOR CONTROL ONLY - DO NOT TEST" 5, AUXILLARY CONTACTS TO SIGNAL ELEVATOR RECALL. PROVIDE 14"C W/ (3)/14 AWC CONDUCTORS TO ELEVATOR CONTROLLER. 6. AUXILLARY CONTACTS FOR FUTURE REMOTE MONITORING. 7, SYSTEM SHALL BE INSTALLED PER WAC 296-96-02277 AND TESTED PER NFPA 72. M ELEVATOR SHUNT -TRIP CONTROL DIAGRAM E5OT SCALE: NONE 277V-14 LIGHTING CIRCUIT N H RELAY PANEL OCCUPANCY SENSOR LIGHTS (TYP) TYPICAL 2-ZONE SWITCHED CONFERENCE ROOM TYPICAL SINGLE ZONE SWITCHED AREA n OCCUPANCY SENSOR WIRING E501 SCALE: NONE ACCEPTABILITY TINS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN COFFMAN DATE 05.23.07 CIILCKLO E. SWEET kN NLEA CHECKED APPROVED APPROVED 05.23.07 PHENOLIC NAMEPLATE (TYPICAL) ELEVATOR CONTROLLER "SHUNT TRIP READY" HEAT DETECTOR CONTACTS IN PARALLEL, REFER TO NOTES 2.3 & 4 KEY OPERATED TEST SWITCH LEGEND .-O DISCONNECT SNITCH, NON -FUSED EQUIPMENT CONNECTION C7 120/208V DISTRIBUTION PANEL ® SMOKE DETECTOR ® HEAT DETECTOR 30AEEy DISCONNECT SWITCH, FUSED, 30A GENE HEVIEWEO COMPLIANCE WiT NFPA 70 - NEC JAN 3 1 ?n14 City of Tukwila �U..3�. G DIVISION REFERENCE DRAWINGS OCCUPANCY SENSOR 10 BE SET UP FOR MANUAL ON AUTOMATIC OFF LA R M TYPICAL OCCUPANCY SENSOR/LCP INTERFACE E�01 SCALE: NONE 9-120 ASIC 100% CD ISSUE SUBTITLE TITLE DETAILS BOEING 9-120 ASIC OFFICE MODERNIZATION ELECTRICAL MASTER BUILDING 9-120 COL. A-F/1-5 DEV. CENTER, WA CURRENT REVISION J#16054201-02 A COFFMAN NGINEERS 1801 RIM Avenue, Suite BOO I SeaBle, OVA B8101 RA 206.04130411 I.200.424.3M com.l.wm LAanNG SYMBOL A DATE 12.12.13 SHEDE501 JOB No. 16054201-02 COMP NO. DWG NO. 09-120-E501 LEGEND: LIGHT FIXTURE SCHEDULE TYPE SYMBOL TOTAL WATTAGE DESCRIPTION MOUNTING FIXTURE TYPE PHILIPS LAMPS BALLAST MANUFACTURERS CATALOG SERIES NUMBER REMARKS VOLTAGE QTY. AM 59 4' RECESSED FLUORESCENT WITH MATTE SILVER ANODIZED SNAP -IN LOUVERS, LOW BRIGHTNESS, HIGH EFFICIENCY RECESS CEILING 277V 3500K T8 32W 2 CLASS P, 2 LAMP T8 ELECTRONIC A SOUND RATING ZUMTOBEL #RIC-2/32-I'X4'-277 m E� 59 2'x4' RECESSED FLUORESCENT RECESS CEILING 277V 3500K T8 32W 2 CLASS P, 2 LAMP T8 ELECTRONIC A SOUND RATING MOTOROLA LITHONIA 2GT-2-32-Al2-277-MOTRN a I liEr I 29 4' UNDER CABINET LIGHT UNDER CABINET 120V 3500K T8 32W I ELECTRONIC BALLAST MOTOROLA LITHONIA #2UC-32-120-MOTRN-SWR W/ROCKER SW. m t c3 I e © 207 8' INDUSTRIAL, 10% UPLIGHT HIGH OUTPUT PENDANT 277V 3500K 800mA HO 110W 2 ENERGY SAVING LITHONIA AF10-2-96-HO-277-ES W/WIRE GUARD var I n T 440 HOLOPHANE INDUSTRIAL PRISMGLO METAL HALIDE, ATHENA OPTICS W/ 60% DOWNLIGHT PENDANT REFER DETAIL 3, SHEET 1E509 277V 3800K SUPER METAL HALIDE I INTEGRAL BALLAST ENERGY SAVING HOLOPHANE BL2C-40LMH-27-J-3-CDP- L7-15-6-PF-I21-A- FI-MS400/C/BU-ONLY FED FROM RECEPTACLE ViIt A 440 HOLOPHANE INDUSTRIAL PRISMGLO METAL HALIDE, ATHENA OPTICS W/ 60% DOWNLIGHT PENDANT REFER DETAIL I, SHEET 1E509 277V 3800K SUPER METAL HALIDE I INTEGRAL BALLAST ENERGY SAVING HOLOPHANE BL2C-4OLMH-27-J-3-0-FI- MS400/C/BU-ONLY HARDWIRED = 59 4' INDUSTRIAL, 10% UPLIGHT PENDENT 277V 3500K T8 32W 2 CLASS P, 2 LAMP T8 ELECTRONIC A SOUND RATING MOTOROLA LITHONIA #AF10-2-32-277-MOTRN W/WIRE GUARD ® ® 118 8' TANDEM INDUSTRIAL 10% UPLIGHT PENDENT 277V 3500K 78 32W 4 CLASS P, 2 LAMP 78 ELECTRONIC A SOUND RATING MOTOROLA LITHONIA #TAFIO-2-32-277-MOTRN W/WIRE GUARD • I n I I 59 4' INDUSTRIAL, 10% UPLIGHT PENDANT 277V 3500K T8 32W 2 CLASS P, 2 LAMP 78 ELECTRONIC A SOUND RATING MOTOROLA LITHONIA #AFIO-2-322-277-MOTRN EMERGENCY LIGHT ® ® 0 59 12114' SURFACE FLUORESCENT ONE PIECE ACRYLIC WRAPAROUND DIFFUSER, WHITE WRAPAROUND ENAMEL FINISH SURFACE 277V 3500K T8 32W 2 CLASS P, 2 LAMP 78 ELECTRONIC A SOUND RATING MOTOROLA LITHONIA WA-2-32-277-MOTRN CORRIDOR m Ella © 59 12"X4' SURFACE FLUORESCENT WITH ONE PIECE ACRYLIC WRAPAROUND DIFFUSER, WHITE ENAMEL FINISH SURFACE 277V 3500K T8 32W 2 CLASS P, 2 LAMP 78 ELECTRONIC A SOUND RATING MOTOROLA LITHONIA WA-2-32-277-MOTRN CORRIDOR EMERGENCY LIGHT m 0 © UNKUM 59 12"X4' SURFACE FLUORESCENT SOLID REFLECTOR EXTERNAL FAST BLOW FUSE SURFACE 277V 3500K T8 32W 2 CLASS P, 2 LAMP T8 ELECTRONIC A SOUND RATING MOTOROLA LITHONIA AFST-2-32-277-MOTRN-GLRX EMERGENCY LIGHT W/WIRE GUARD m Ark 59 12"X4' SURFACE FLUORESCENT SOLID REFLECTOR EXTERNAL FAST BLOW FUSE SURFACE 277V 3500K T8 32W 2 CLASS P, 2 LAMP TB ELECTRONIC A SOUND RATING MOTOROLA LITHONIA AFST-2-32-277-MOTRN-GLRX W/WIRE GUARD m ® Agik 118 8' TANDEM INDUSTRIAL SOLID REFLECTOR EXTERNAL FAST BLOW FUSE SURFACE 277V 3500K 78 32W 4 CLASS P, 2 LAMP 78 ELECTRONIC A SOUND RATING MOTOROLA LITHONIA #TAFST-2-32-277-M0TRN-GLRX W/WIRE GUARD MU I n 1 I SYM REVISION BY APPROVED DATE SYM REVISION BT APPROVED DATE A MOVE BCAG ENG HOLD 4137070-30 ERICKSON VAVREK 9/29/95 BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-DO 8RM CEI 12.12.13 ce;LAsnow-iivc. ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN BENNETT REVIEWED FOi COMPLIANCE WITH NFPA 70 - NEC JAN 3 1 71114 City of Tukwila BUILDING DIVISIr'^' DATE VAVREK I VAVREK GENERAL NOTES: CONSTRUCTION NOTES: FOR REFERENCE ONLY FACILITY DESIGN BY DATE 9-120 ASIC 100% CD ISSUE SUBTITLE LIGHTING FIXTURE SCHEDULE RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER AFOFFMAN NGINEERS 1601 PAD Avenue, Suite GOO I Seattle, WA8G101 ph 2011029A71T I WA lel.STA]TTG corn LASTING CURRENT REVISION 131174-00 SYMBOL B DATE 12.12.13 ENGINEER BENNETT CHECKED VAVREK APPROVED MEHTA APPROVED 11/22/94 TITLE BOEING 9-120 ASIC OFFICE MODERNIZATION ELECTRICAL MASTER BUILDING 9-120 COL. A-K/1-9 DEV. CENTER, WA GREET 1 E506 E* JOB NO. COMP ND. DWG NO. 9-120-1E506 Wi S'M LEVEL 1 B REVISION XH3/14 APPROVED DATE SYM LEVEL 1 A Sw#1 500VA XK3/1 EXIST. NW CORRIDOR 109 XH3/1a,10b (OLD 8N) REASION Stairwell #1 - Northwest A LEVEL 2A L, AEVEL 2B SCALE: 1/4"=1' BY APPROVED DATE A REPLACE STAIRWELL LIGHTS 57791400 ESBROOK 02.26.08 BOEING 9-120 ASIC OFFICE MODERNIZATION 131174—DO BRM CEI 12.12.13 1E10 1E547 pirdsrAF,Avc LEVEL 3A / 4 \ REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JAN 3 1 2014 City of .Tukwila BUILDING DIVISION ACCEPTABILITY THIS DESIGN AND/DR SPECIFICATION IS APPROVED APPROVED OR DEPT. DATE DRAWN DATE R.HEL'NLu 1 XH3/6 @ Column C-3 0 CONSTRUCTION NOTES PROVIDE NEW PENDANT -MOUNTED LUMINAIRE, CONNECT TO EXISTING STAIRWELL EMERGENCY CIRCUIT. VERIFY MOUNTING HEIGHT WITH ARCHITECTURAL DRAWINGS. a 9-120 ASIC 100% CD ISSUE SUBTDLE -StairwaysN01 NW IVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER ACOFFMAN NGINEERS 1601 FATE Avenue, Suite 9001 Seethe. W A98101 eh 0e0.023.071711a. 200.e04.0170 cmmmen am LAsnua ,.,,., I... 'MOM. CURRENT REVISION 131174-00 SYMBOL DATE 12.12.13 ENCITEI.LH CHECKED APPROVED APPROVED TALE BOEING 9-120 ASIC OFFICE MODERNIZATION (DISCIPLINE) MASTER BUILDING 09-120 COL. X-X/X-X SITE SHEET 1E547 E* JOB NO. COMP NO. 09-120-1E547 SON LIGHT FIXTURE SCHEDULE TYPE DESCRIPTION MOUNTING FIXTURE VOLTAGE LAMPS BALLAST MANUFACTURERS CATALOG SERIES NUMBER REMARKS SYMBOL TYPE OTY. WALL MOUNTED LED LUMINAIRE WALL MOUNTED 277 V LED 1 LED DRIVER DESIGN PLAN # PT11-12-1—D—B P 27 PENDANT LED LUMINAIRE, NOMINAL 20" PENDANT 277 V LED 1 LED 0-10V DIMMING M0001 # RANDOM—LED- 020 DIAMETER DRIVER ULMOLRAL—S 25 PENDANT LED LUMINAIRE, NOMINAL 32" PENDANT 277 V LED 1 LED 0-10V DIMMING M0001 // RANDOM—LED- 032 DIAMETER DRIVER ULMOLRAL—M 35 WALL MOUNTED LINEAR FLUORESCENT WALL MOUNTED 277 V F32W 4878 2 2 LAMP ELECTRONIC PINNACLE # E4A-2T8-8—WA R8 LUMINAIRE BALLAST —277-1C—W 55 1X4 RECESSED FLUORESCENT LAY —IN RECESSED 277 V F32W 4878 2 2 LAMP ELECTRONIC DAYBRITE # 4—D—G-2-32-01— LUMINAIRE BALLAST 277 55 PENDANT LED CYLINDER DOWNLIGHT PENDANT 277 V LED 1 LED DRIVER LIGHTOLIER }JC4L10C—W-35— I 1 LUMINAIRE CCL—U—VA 20 PENDANT LINEAR FLUORESCENT PENDANT 277 V F32W 4878 2 2 LAMP ELECTRONIC PINNACLE #EX2B—A-0-1-1-4 PROVIDE CONTINUOUS RUNS INDIRECT/DIRECT LUMINAIRE DIMMING BALLAST AC48G1—UNV-1C—W—DG WHERE SHOWN ON DRAWINGS 55 PENDANT LINEAR FLUORESCENT PENDANT 277 V F25W 4875 1 1 LAMP ELECTRONIC PINNACLE iEX2—A—N-1T5-4— PROVIDE CONTINUOUS RUNS DIRECT LUMINAIRE DIMMING BALLAST AC48G1-1D—W WHERE SHOWN ON DRAWINGS 30 LED TAPE LIGHT MOUNTED TO METAL FRAME INSIDE STRETCHED FABRIC RIBBONS SURFACE 277 V LED LED DRIVER DIMMING BALLAST LUMINII JLL18—S-24K—X—X— —650 PROVIDE 20 DRIVERS, LOCATIONS TO BE FIELD REFER 70 DETAIL I, THIS SHEET, FOR MOUNTING DETAIL COORDINATED WITH RIBBON MANUFACTURER 10 TYPE DESCRIPTION LAMPS MOUNTING LICHTOLIER fCF—S-2—G—P— F-2-32-277—HI F32T8/35K RECESSED CA 61 LIGHTOLIER #KW-4—A-2— 32-277—HI F32T8/35K SURFACE LIGHTOLIER (r'SL—B-1—S— 32-277—HI F32T8/35K SURFACE C1 LIGHTOLIER #SL—B-1-S- 32-277—DIMMING F32T8/35K SURFACE 61 D EDWARDS SIGNAL 120V 40W SURFACE 30 F LIGHTOLIER #8031—CCDP- 561328U 32W/TRT RECESSED 37 G LIGHTOLIER #EX—X—G—X— RC—C—N 3W LED UNIVERSAL 3 H LIGHTOLIER i404722XU3— 404SKG-40421 (2)42W/TRT PENDANT 84 Hi LIGHTOLIER ij404722XU3KD— 412DK-4120G (2)42W/TRT PENDANT 84 Q LIGHTOLIER iTCU40W-120—HI F32T8/35K UNDER CABINET ® © TARGETTI 12V VIP TRACK HEAD WITH SURFACE MOUNT US47670 BASE AND 20" STEM (1)50W/MR16 PENDANT m j, LIGHTOLIER 2)12W SURFACE Ix,#E2-2-50N—T12—B—SD Q CREE LIGHTING CS18-75L-40K—TOV WITH ADDITIONAL SO" ADJUSTABLE AIRCRAFT CABLES. 75W PENDANT ® REVISION BY APPROVED OUICK CONNECTS AT STRUCTURAL RIG POINTS. LOCATIONS TO BE COORDINATED WITH RIBBON MANUFACTURER. DALE SVM LED DRIVER, SECURED TO STRUCTURE OR TOPSIDE OF ADJACENT GYP CEILING. LOCATIONS TO BE FIELD COORDINATED. NO MORE THAN 40'—D" OF LED TAPE CAN BE SERVED BY ONE DRIVER. LOW —VOLTAGE WIRING LED TAPE LIGHTING (TYPE W) SECURED TO UNDERSIDE OF TOP OF FRAME WITH HEAT —CONDUCTIVE TAPE LOW VOLTAGE WIRING CONNECTION TO ADJACENT FRAME SECTION WHERE APPLICABLE. CONNECTIONS TO BE FIELD COORDINATED WITH RIBBON MANUFACTURER. L CUT TAPE AND PROVIDE WIRE CONNECTOR 70 JUMP AROUND CENTER SUORT TYPICAL FRAME PPSECTION 2E15000 SCALE: NOT TO SCALE REVISION BY APPROVED DATE A FACILITIES SUPPORT 9-120 737099-02 DHARR N. MEHTA 5-19-3 BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-00 BRM CEI 12.12.13 LIGHT FIXTURE SCHEDULE TYPE DESCRIPTION MOUNTING FIXTURE VOLTAGE LAMPS BALLAST MANUFACTURERS CATALOG SERIES NUMBER REMARKS SYMBOL TYPE OTY. RECESSED 1X4 LAY IN FLUORESCENT DIRECT LUMINAIRE RECESSED 277 V F32W 48T8 2 2 LAMP ELECTRONIC DIMMING BALLAST LEDALITE ij 9714—DI—ST—T232— S-7-2—E 55 88 PENDANT DIRECT 8' LINEAR FLUORESCENT LUMINAIRE PENDANT 277 V F32W 4878 4 (2) 2 LAMP ELECTRONIC BALLAST PINNACLE rY EX4S—A—N-2T8-8 AC48ST-277-1C-W PROVIDE CONTINUOUS RUNS WHERE SHOWN ON DRAWINGS 108 RECESSED 4' LINEAR FLUORESCENT WALL WASH LUMINAIRE RECESSED 277 V F54W 48T5H0 1 1 LAMP ELECTRONIC DIMMING BALLAST PINNACLE # EW-1T5H0-4—G1C —277-1C-W 61 C8 RECESSED 8' LINEAR FLUORESCENT WALL WASH LUMINAIRE RECESSED 277 V F54W 48T5H0 2 2 LAMP ELECTRONIC BALLAST PINNACLE iEW-1T5H0-8—G1G —277-1C-W 118 p1 RECESSED 4" LED DOWNLIGHT RECESSED 277 V LED 1 LED DRIVER OMEGA #OM4LED-26-8-30K —WF-277—XX-R4LED-XX-CS 26 15 p2 PENDANT LED FLOOD LUMINAIRE PENDANT 277 V LED 1 LED DRIVER COLOR KINETICS jJ 525-0059— 03 WITH SPREAD LENS #120— 000080-06 LINEAR FLUORESCENT STRIP LUMINAIRE, ASYMMETRIC REFLECTOR, STAGGARED LAMPS SURFACE 277 V FLUORESCENT 2 2 LAMP ELECTRONIC DIMMING BALLAST DAYBRITE }JSSR-2-32—UNIV-1/2 -10 55 n COLOR CHANGING LED COVE LUMINAIRE, 6" LENGTHS SURFACE 277 V LED I LED DRIVER COLOR KINETICS ij 101-000066 —02 3 RECESSED LED DOWLIGHT LUMINAIRE RECESSED 277 V LED I LED DRIVER LIGHTOLIER ✓f C3L085N—UZ1OVAIC —C3L085DL-01-30K-8—C3LDL-W —CL-W PO r-\ LINEAR LED UNDERCABINET LUMINAIRE, INTEGRAL VACANCY SENSOR SURFACE 120 V LED 1 LED DRIVER COLOR KINETICS # 523-000027— 74 20 SURFACE LED SPOT LUMINAIRE, SIX LED MODULES PER LUMINAIRE RECESSED 277 V LED 1 LED DRIVER BETA CALCO # 51-1063—WD—CL 186 SURFACE LINEAR FLUORESCENT INDUSTRIAL STRIP LUMINAIRE SURAFCE 277 V F32W 48T8 2 2 LAMP ELECTRONIC BALLAST DAYBRITE # IA-2-32-277 PROVIDE WIRE GUARDS AND LAMP SLEEVES 55 S PENDANT LINEAR FLUORESCENT WALL WASH LUMINAIRE PENDANT 277 V F54W 48T5H0 2 2 LAMP ELECTRONIC BALLAST PINNACLE #EX44—WVI-N-1T5H0 —6—PP_JB-277-1C-W PROVIDE CONTINUOUS RUNS WHERE SHOWN ON DRAWINGS 116 M2 FLEXIBLE LED TAPE LUMINAIRE SURAFCE 277 V LED 1 LED DRIVER LUMINII fi LLX22—S-30K—XX-XXX INPUT WATTS LISTED, WATTS PER LINEAR FT 4.6 N RECESSED DIRECT FLUORESCENT LUMINAIRE RECESSED 277 V F32W 4818 2 (2) 2 LAMP ELECTRONIC DIMMING BALLAST PINNACLE # E4A-2T8-8—GIG —277-1C—W 55 N16 RECESSED DIRECT FLUORESCENT LUMINAIRE RECESSED 277 V F32W 46T8 8 (4) 2 LAMP ELECTRONIC DIMMING BALLAST PINNACLE # E4A-2T8-16—G1G —277-1C—W 2?D COFFMAN N G I N E E R S 1601 Fifth Awns, Sully ODD I So. , TVA 98101 ph 206.920.0SIS I ICI 206@4ATIA coBinn.con ELM ) COMPLIANCE WITH NFPA 70 - NEC JAN 3 1 2014 City of Tukwila 3UILDING DIVISION 9-120 ASIC 100% CD ISSU E ACCEPTABILITY THIS DESIGN AHD/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN EDDIE P. DUARTE CHECKED 9/17/91 SUB. -ELL 2ND FLOOR LIGHTING SCHEDULE RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER CURRENT REVISION 131174-00 SYMBOL DATE 12.12.13 t NUINtFN 'CNLCKLD APP ROVLD APPROVED TITLE BOEING 9-120 ASIC OFFICE MODERNIZATION BLDG. 9-120.2 ELECTRICAL MASTER ALL D.C. SHEET 2E500 E* JOB NO. 737099-02 COMP NO. DWG NO. 9-120-2E500 Net, 111,1 RELAY IN LIGHTING CONTROL PANEL LEGEND Neutral Hot - BI ht Loco) Switch Red Power1 Pock T Red • 0 0 NOTE: MAXIMUM NUMBER OF SENSORS PER POWER PACK DEPENDS ON THE MODEL DF SENSOR. SEE THE PRODUCT DATA SHEET TO DETERMINE THE SPECIFIC CURRENT CONSUMPTION OF EACH SENSOR. ISOLATED RELAY REO ORG BRUT BLU YL •RLY CO •N.O. • N.C. G LOT. LEVEL CTRL OUT. MAN. SW VIOL •A24V GRA `•COMMON N OCCUPANCY SENSOR ♦ M TYPICAL OCCUPANCY SENSOR WIRING DIAGRAM 2E501 SCALE: NONE 120V POWER • C3— ®DIMMING MODULE • 11:::>-DIMINNO MODULE • • • © DI • NC MODULE 0CC SENSOR POWER PACK 277V POWER 0-3#16 GRATIK EYE OS > 11 Ie ZONE' 1 Q > 11 I k ZONE' 2 .<-] > 11 1k ZONE' 3 d_ OCC SENSOR Q1 OSSPS-PI-I-50 OS LINK POWER SUPPLY a(H) X 2.75(W) X 1.25(0) (PLUGS INTO DUPLEX RECEPTACLE) { NORMAL LINE NORMAL NEUTRAL SENSING" LINE EMERGENCY LINE 'SWITCHING' LINE NORMAL SWITCHED SENSE EMERGENCY POWER OUT NORMAL NEUTRAL NORMAL POWER SENSE EMERGENCY NEUTRAL EGRESS LTG I I EMERGENCY POWER IN P/ 101F51 EMERGENCY NEUTRAL EMERGENCY LIGHTING CONTROL UNIT (ELCU-200) WIRING DIAGRAM 2E501 SCALE: NONE ITEQO UIPAV MENT OSE-IC CONTACT CLOSURE • 2#12 AWG (2.5mm2) M TYPICAL CONFERENCE ROOM CONTROL WIRING DIAGRAM 2E5001 SCALE: NONE I/ 277VAC 2#I8AWG CABLE DOUGLAS PWEXW36M-S3 36 RELAY LIGHTING CONTROL PANEL POWER PACK 4-CONDUCTOR #16 BELDEN TWISTED SHIELDED CABLE LV DOUGLAS ELAN SWITCH WITH BUTTON QUANTITY PER FLOOR PLANS 3 -TOO AV EDUIPMEM CRX-CI-RS232 RS232 INTERFACE SURFACE MOUNT INTERFACE TO OTHER SYSTEMS 3I1BAWG CABLE M TYPICAL LIGHTING CONTROL PANEL RISER DIAGRAM 2E501 SCALE: NONE REVISION BY APPROVED DATE SYM REVISION TO OTHER SWITCHES BY APPROVED DATE ORIG BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-00 BRM CEI 12.12.13 Neutral WEE Operation: LS-301 dims lights as daylight increases. 2E501 Violet Neutral E ectronic Dimming Ballast (0 - 10 VDC) ht Red °Not Used (cap with e nut) TYPICAL WATTSTOPPER PHOTOCELL WIRING DIAGRAM SCALE: NONE Unswitched Hot Blk 120/277 �BOE/A/6 rn Eorih Ground 0-IOVDC Dimmin Ballast for fixture Red Llghling SYMBOL:® • II � I LMRC-213 Triple Relay On/O11/0-10V Dimming Room Controller 0000 IQ011QI001 Lighting Class 2 0-1D Volt Control Wring 2 OR MORE ZONES 1 ZONE WSW- 05-W LMSW-104-W SYMBOL:D2$D0Db SYMBOL. D$D 10 NEXT ROOM CONTROLLER REVIEWED FOR GENERAL NOTES LIGHTING CONTROL PANEL WITH THE FOLLOWING FEATURES: — 36 RELAYS —(2)WNX-2624 NETWORK NODES —(2)WRS-2224 RELAY SCANNERS — (1)WTP-4408 TIME CONTROLLER REFERENCE DRAWINGS CONSTRUCTION NOTES OCCUPANCY SENSOR TO BE SET UP FOR MANUAL ON AUTOMATIC OFF. 2v OCCUPANCY SENSOR LOCATED AT STAIRWELL DOORS, IN ELEVATOR LOBBY AND IN THE FREIGHT ELEVATOR LOBBY TO ACTIVATE RELAY ASSOCIATED WITH EGRESS LIGHTING. PROVIDE 277V POWER TO LCP2B2-1 FROM 2B2-1" PANELBOARD. RECORD CIRCUIT USED ON PANEL SCHEDULES. ® COORDINATE WITH FIRE ALARM CONTRACTOR TO PROVIDE A NORMALLY CLOSED CONTACT TO OPEN AND TURN ON EGRESS LIGHTING WHEN FIRE ALARM IS ACTIVATED. COMPLIANCE WITH NFPA 70 - NEC JAN 3 1 71114 City of Tukwila BUILDING DIVISION JJ PROVIDE (1) LMCT-100 DIGITAL WIRELESS CONFIGURATION TOOL FOR THIS PROJECT. CONTRACT WITH LOCAL WATTSTOPPER REP TO PROVIDE A FULLY FUNCTIONAL AND COMMISSIONED SYSTEM. PROVIDE 277V:24VDC TRANSFORMERS AS REQUIRED TO POWER ALL LIGHTING CONTROL PANEL COMPONENTS. PROVIDE 0-10V DIMMING MODULE. REFER TO FLOOR PLANS FOR ACTUAL NUMBER OF ZONES. COORDINATE SCENE PROGRAMMING WITH LIGHTING DESIGNER PRIOR TO SYSTEM COMMISSIONING. CONNECT WIRING TO EGRESS RELAY INPUT. IN ROOMS WOW 1 ZONE PROGRAM THE 4 BUTTONS AS FOLLOWS: <1 SINGLE ZONE ROOM: BUTTON 1: LIGHTS DIM UP BUTTON 2: LIGHTS ON 100% BUTTON 3: LIGHTS LIGHTS OFF BUTTON 4: LIGHTS DIM DOWN IN ROOMS WITH 2 ZONES PROGRAM 4 SCENE BUTTON WITH DIMMER AS FOLLOWS: <: BUTTON 1: ZONE A ON, ZONE B ON BUTTON 2: ZONE A ON, ZONE B OFF BUTTON 3: ZONE A OFF. ZONE B ON BUTTON 4: LIGHTS OFF ROCKER SWITCH TO PROVIDE UP/DOWN DIMMING CONTROL TYPICAL DLM PHOTOCELL WIRING DIAGRAM 2E501 SCALE: NONE ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN MK DATE 12.12.13 CHLCIILD CEI 12,12.13 9-120 ASIC 100% CD ISSUE SUBTITLE LIGHTING CONTROL DETAILS RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER CURRENT REVISION 131174-00 SYMBOLORIG DATE 12.12.13 NUINLLH CHECKED APPROVED APPROVED BOEING 9-120 ASIC OFFICE MODERNIZATION ELECTRICAL MASTER BUILDING 9-120 COL. A—F/1-5 DEV. CENTER, WA SHEET2E501 JOB No. 131174-00 COMP NO. DWG NO. 09-120-2E501 NOTES: CART, pA.O I J uw1 s+sTEM ENG El CON, IN PAO ETHERNET IN tpp- 040VAC rc CATSe DATA CARL 66666666 C t00-240VAC s" TO ADDITIONAL ETHERNET SWITCHES ETHERNET SWITCH 100-24PIAC i� ii I 0,010 we vte haler Cum OLX leader Cable: 30-legit (9 m) ETHERNET IN.., tpp-2aMAC PDS-60/6 24V DMv/ETHERNET IN - ETHERNET PDS-60co 24V 0112/ETHERNET 100-240VAC 0 ADDIT10144L PDS DANCES CONFERENCE ROOM ACCENT LED CONTROL WIRING DIAGRAM 2E502 SCALE: NONE PDS 1 i ETHERNET SWITCH Q PDS PDS ETHERNET CONTROL KEYPAD 1 PDS 1 LIGHT MANAGEMENT SYSTEM (LMS) ETHERNET SWITCH IL L_ PDS 1 ETHERNET SWITCH Q7 PDS PDS 1 PDS PDS CONFERENCE ROOM ACCENT LED CONTROL ONE LINE DIAGRAM 2E502 SCALE: NONE SYM REVISION ORIG BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-00 BRM APPROVED DATE CEI 12.12.13 SYM REVISION ETHERNET SWITCH PDS APPROVED I� PDS 1 1 DATE 1 I� PDS PDS 1 1. PLACE A DATA TERMINATOR IN THE DMX LOOP OUT PORT OF THE LAST PDS UNIT IN THE DAISY -CHAIN. 2. THE LEADER CABLE IS CONNECTORIZED TO ENSURE FAULTLESS WIRING. DO NOT REMOVE OR REPLACE THE FACTORY INSTALLED CONNECTORS. 3. DO NOT SHORTEN, LENGTHEN, OR MODIFY THE LEADER CABLE. CUTTING THE LEADER CABLE MAY DAMAGE THE DATA DRIVE CIRCUITRY. 4. CONNECT ICOLOR COVE OL END TO END USING THE INLINE CONNECTORS. 5. MAXIMUM NUMBER OF FIXTURES PER PDS-60CA 24V: 6" - 30 (ALL ON OUTPUT 1 OR DIVIDED BETWEEN OUTPUTS 1 AND 2) 6. MAXIMUM CAT5 RUN BETWEEN DEVICES IS 330 FEET, PDS-60co 24V DMX/ETHERNET CONTROL UNIT (30) 6" RGB COVE FIXTURES PER PDS UNIT TWO-WAY ADJUSTMENT FOR INTENSITY AND COLOR TUNING 5 8 PUSH BUTTON FOR SCENE/PROGRAM SELECTION LED INDICATOR LIGHT FOR ACTIVE SCENE/PROGRAM M ETHERNET CONTROLLER KEYPAD 2E502 SCALE: NONE LEGEND — - - — - - — CAT5 DMX CABLE QO BY CONTRACTOR ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JAN 3 1 2014 City of Tukwila BUILDING DIVISION "DATE 12.12.13 CHLCHLD CEI ENGINLER CHLCHED APPROVLD APPROVED 12.12.13 GENERAL NOTES 1. CONTRACTOR SHALL INCLUDE 12 HOURS OF VENDOR TIME FOR PROGRAMMING AND COMMISSIONING OF LIGHTING SYSTEM. 2. ALL DEVICES, CABLING, SWITCHES, ETC. IS TO BE PROVIDED BY THE ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. REFERENCE DRAWINGS 09-120-2E10 CONSTRUCTION NOTES REFER 70 SHEETS 2E10 AND 2E12 FOR RUN LENGTHS AND LOCATIONS OF LUMINAIRES. 122> PROVIDE CONTROLLER KEYPAD LOCATED NEAR OFFICE ASSISTANT 23A3. I> PROVIDE LIGHTING SYSTEM MANAGER LOCATED ABOVE ACCESSIBLE CEILING IN CONFERENCE ROOM 21B4. ® PROVIDE (7) PDS-60CA 24V DMX/ETHERNET DEVICES ABOVE ACCESSIBLE CEILING OF CONFERENECE ROOMS 21B4, XXXX, XXXX, AND (1) PDS-60CA 24V DMX/ETHERNET DEVICE ABOVE RECEPTION DESK. REFER 10 DETAIL 2/2E502. © ROUTE SERIAL CABLE TO KEYPAD IN CONDUIT SIZED 10 ACCOMMODATE CABLING. PROVIDE UNMANAGED 8-PORT INDUSTRIAL ETHERNET SWITCH MOUNTED ABOVE ACCESSIBLE CEILING SPACE. CIRCUIT TO NEAREST 120V CIRCUIT. NTRON OR EQUAL. ® PROVIDE 120:24VDC TRANSFORMER. CONNECT TO NEAREST 120V CIRCUIT. RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER 9-120 ASIC 100% CD ISSUE SUBTITLE TITLE LIGHTING CONTROL DETAILS BOEING 9-120 ASIC OFFICE MODERNIZATION ELECTRICAL MASTER BUILDING 9-120 COL. A-F/1-5 DEN. CENTER. WA COORDINATE EXACT LOCATION OF CONTROLLER WITH LIGHT FIXTURES SERVED SO CABLE IS NO LONGER THAN 30-FEET. CABLING BETWEEN ETHERNET SWITCHES, LMS AND CONTROL PAD TO BE RUN IN CONDUIT. AKOFFMAN NGINEERS CURRENT REVISION 131174-00 1601 Fifth Avenue, Sidle 9001 Seattle, WA 96101 ph 206.620e>171 fax 206.624.0T76 eoffman.com STWH00 R I G DATE 12.12.13 SHEET JOB N0. 2E502 131174-00 COMP ND. DWG ND, 09-120-2E502 GENERAL NOTES SYM STRUCTURAL CEILING VC FOR POWER [-CONDUIT STUBBED UP TO ACCESSIBLE CEILING SPACE PER AV DRAWINGS ly"C WITH PLASTIC GROMMET ON END FOR TELECOM STUBBED INTO ACCESSIBLE CEILING O WE FOR 1y,"C WITH TELECOM SPACE CONDUIT ACCESSIBLE AV DRAWINGS POWER PLASTIC GROMMET STUBBED INTO ACCESSIBLE STUBBED UP TO CEILING SPACE C FOR POWER ON END FOR CEILING 5�CONDUIT STUBBED UP 10 ACCESSIBLE CEILING SPACE PER AV DRAWINGS PER 1Y"C WITH PLASTIC GROMMET ON END FOR ORSPACE TELECOM STUBBED INTO ACCESSIBLE CEILING SPACE CEILING GRID rLCOM2Q /-LCONIQ SINGLE GANG J-BOX FOR TELECOM SINGLE GANG J-BOX FOR ,/TELECOM 0 O SYMBOL VLCD - O O SYMBOL SZLCO< 1C7 0 0 0 TERMINATE CONDUIT IN WALL BOX. PROVIDE PLASTIC GROMMET ROUNDING LUG (TIP OF 2) 0 0 0 0 0 0 m =SYMBOL 0 0 0 TERMINATE CONDUIT IN WALL BOX. PROVIDE PLASTIC GROMMET ROUNDING LUG (TYP OF 2) 0 0 0 0 0 0 DI N _ _ _ _ 0 0 Q —LCD BACK BOX Q SYMBOL N ` _ _ _ _ 0 0 BOX ©�Q Q \—ICDSYMBOL (1)20A DUPLEX RECEPTACLE / SYMBOL f! MOUNTED IN BOXFOR LCO if LCD / SYMBOL (1)2GA DUPLEX RECEPTACLE J ,,1yy MOUNTED IN BOXFOR LCD co2SL DOUBLE DUPLEX RECEPTACLE SYMBOL SYMBO SYMBOL it Q ESI SINGLE GANG J—BOX FOR TELECOM J—BOX FOR AV Q FLOOR T. PROVIDE PULL STRING ALL EMPTY RACEWAYS. CONSTRUCTION NOTES COVENDORORDINATE ELECTRICAL DEVICE INSTALLATION LOCATION AND SIZE WITH BACK BOX LCD CONFIGURATION MAY BE EITHER (1)LCD CENTERED ON THE WALL OR (2 )LCD'S SIDE BY SIDE (SHOWN). WHERE ONLY (1) LCD OCCURS ONLY PROVIDE OUANTIIY OF DEVICES 10 REQUIRED FOR (1) LCD BACK BOX. COORDINATE EXACT LOCATION WITH AV INSTALLER AND ARCHITECT. ® COORDINATE LOCATION WITH ARCHITECTURAL FURNITURE LAYOUT. WHERE A TABLE IS AT, THE WALL BELOW THE LCD SCREENS MOUNT DEVICES ABOVE TABLE 10 HEIGHT. WHERE NO TABLE IS AT, THE WALL MOUNT DEVICES AT 113" AFF. PROVIDE CONDUIT AND BACK BOXES PER AV DRAWINGS. REVIEWED FObd COMPLIANCE NFPA 70 - NFC JAN 1 In14 City of .Tukwila BUILDING DIVISIC REVISION BY APPROVED DATE SYM TYPICAL ROOM LCD WALL DETAIL 2EE503 SCALE: NONE REVISION OX APPROVED DATE ORIG BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-00 MOM CEI 12.12.13 cl._,ISTZFEAVAW Can ;'R/OSIL tiy. ACCEPTABILITY -MK DATE DR 12.12.13 THIS DESIGN AND/OR CHECKED SPECIFICATION IS APPROVED CEI 12.12.13 UNCINLLN APPROVED BY DEPT. DATE CUECOD APPROVED APPROVED 9-120 ASIC 100% CD ISSUE SUBTITLE AN AND WALL MOUNTED LCD DETAILS TITLE BOEING 9-120 ASIC OFFICE MODERNIZATION ELECTRICAL MASTER BUILDING 9-120 RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER COL. A—F/1-5 DEV. CENTER, WA CURRENT REVISION 131174-00 COFFMAN NGINEERS 1001 FINN Avenue. sue B001 Bepnk. WA 9B101 ph 20E.021.0717 I fax 2N024.3773 caftmeneorn LASTING an vane -a —ORIG DATE 12.12.13 SHEET 2E503 JOB NO. 131174-00 COMP NO. DWG NO. 09-120-2E503 .11.2011 LEGEND 2A7-6/32D,34b,36c,38o REVISION n DATA ROOM 2E504 SCALE: 1/4" = 1.-0" BY APPROVED DATE SVM RACK REAR NEMA 16-20R RECEPTACLE 0 0 0 00 0 RACK SIDE DCN ROOM RACK RECEPTACLE MOUNTING DETAIL 2E504 SCALE: NONE REVISION IW APPROVED DATE ORIG BOEING 9-120 ASIC OFFICE MODERNIZATION 131174-00 BRM CEI 12.12.13 lie:LAMPE/AVG WAR 0" x 4" x 10" COPPER GROUND BAR WITH WALL MOUNTING BRACKETS AND INSULATORS CPI991G622-010 PROVIDE EXOTHERMIC BOND (CADWELD OR EQUAL) TO GROUND BAR 0 0 OO O 0 DO O O O 0 O O O PROVIDE ONE (1) #6 AWG STRANDED GREEN GROUND TO EACH EQUIPMENT RACK PROVIDE EXOTHERMIC BOND (CADWELD OR EQUAL) TO GROUND BAR NOTE: NOT ALL PARTS AND PART NUMBERS ARE SHOWN. THE CONTRACTOR IS RESPONSIBLE FOR A COMPLETE WORKING INSTALLATION INCLUDING, MISCELLANEOUS APPURTENANCES. M GROUND BUS BAR ASSEMBLY 2E504 SCALE: NONE ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN MK PROVIDE ((2 STRANDED GREEN GROUND CONDUCTOR IN 1/2" EMT TO MAIN SERVICE GROUND BUS. COMPLY WTH ANSI -J- STD -607-A-2002 REQUIREMENTS REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JAN 3 1 2014 City of Tukwila BUILDING DIVISION DATE 12.12.13 CHECKED CEI 12.12.13 GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES 11> PROVIDE (4) L6-2DR RECEPTACLES MOUNTED BELOW RACK. COORDINATE EXACT LOCATION AND INSTALLATION SEQUENCE WITH NETVERSANT. REFER TO 2/2E504. PROVIDE (1) L5-2DR RECEPTACLE MOUNTED BELOW RACK. COORDINATE EXACT LOCATION AND INSTALLATION SEQUENCE WITH NETVERSANT. REFER TO 2/2E504. PROVIDE NEW GROUND BAR WITH 1#2 AWG GROUND WIRE TO BUILDING GROUNDING LOOP. REFER TO 3/2E504. RECEIVED CITY OF TUKWILA JAN 1 4 2014 PERMIT CENTER 9-120 ASIC 100% CD ISSUE SUB, ,,LE DCN ROOM DETAILS ACOFFMAN NGINEERS CURRENT REVISION 131174-00 1BO1 Fifth Avenue, Suite 900 I Se66l, WA BBIDI p0206.623g111113c 200.624.3713 cartm3ncam SVMBDLO P G DATE 12.12.13 INC INELR —CHECKED APPROVED APPROVED TITLE BOEING 9-120 ASIC OFFICE MODERNIZATION ELECTRICAL MASTER BUILDING 9-120 COL. A-F/1-5 DEV. CENTER, WA SHEET JOB NO 2E504 131174-00 COMP NO. DAG NO. 09-120-2E504