Loading...
HomeMy WebLinkAboutPermit EL14-0143 - KING COUNTY / METRO - LIGHTINGKING COUNTY METRO 6000-6198 SOUTHCENTER BLVD EL14-0143 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No: STRT-01453 Permit Number: EL14-0143 Address: 6000-6198 SOUTHCENTER BLVD Issue Date: 2/27/2014 Permit Expires On: 8/26/2014 Project Name: KING COUNTY METRO Owner: Name: Address: , , WA, Contact Person: Name: MIKE SHAFFER Phone: (206) 730-9755 Address: 2332 JEFFERSON AVE , TACOMA, WA, 98402 Contractor: Name: TOTEM ELECTRIC OF TACOMA INC Address: PO BOX 1093 , TACOMA, WA, 98401 License No: TOTEMET315BS Lender: Name: Address: Phone: (253) 383-5022 Expiration Date: 9/30/2015 DESCRIPTION OF WORK: INSTALL CONDUIT, WIRE, PEDESTRIAN LIGHT, AND SERVICE PEDESTAL FOR KING COUNTY METRO TRANSIT BUS STATION AT ZONE 58102. FOLINE RAPID RIDE. WO #80. Valuation of single family: $0.00 Valuation of mf/comm: $12,000.00 Type of Work: REMODEL Fees Collected: $399.36 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer Distric: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2012 2012 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attachto this permit. Signature: ,tr Print Name: nz_E-c-rsE-Q_ A- 1-c7A- "" - Date: 2-'—�-7 / This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWIL A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** ON Site Address: Southcenter Blvd and 62nd Ave S Tenant Name: King County Metro King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: ❑ Yes ❑ ..No PROPER OAR Name: King County Metro'Transit Address: 201 South Jackson Street KSC-TR-0433 City: Seattle State: WA Zip: Name: Mike Shaffer Address: 2332 Jefferson Avenue City: Tacoma State: WA Zip: 98402 Phone: (206) 730-9755 Fax: (253) 272-5214 Email: ELEcr*Ic� N tC' .. RMAION Company Name: Totem Electric Address: 2332 Jefferson Avenue City: Tacoma State: WA Zip: 98402 Phone: (253) 383-5022 Fax: (253) 272-5214 Contr Reg No.: TOTEMET315BExp Date: 08/31/2014 Tukwila Business License No.; v ct ry `i s' a Valuation of Project (contractor's bid price): $ 12,000 Scope of Work (please provide detailed information): Install conduit, wire, pedestrian light, and service pedestal for King County Metro Transit bus station @ Zone 58102. F-Line Rapid Ride. WO #80. Will service be altered? ❑ Yes ❑ No Adding more than 50 amps? ❑ Yes ❑ No Type of Use: Type of work: ❑ New ❑ Addition 0 Service Change ❑ Remodel ❑ Tenant Improvement O Low Voltage 0 Generator 0 Fire Alarm 0 Telecommunication 0 Temporary Service Property Served by: Puget Sound Energy 0 Seattle City Light li.\Applications \Forms -Applications On Line\2014 Applications\Electrical Permit Application Revised 1-1-14.docx Revised. January 2014 hh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $65.00 ❑ Temporary service (generator) $80.90 ❑ Manufactured/mobile home service $86.25 (excluding garage or outbuilding) ❑ Carnivals $80.60 Number of concessions $10.80 ea Each ride and generator truck $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and, justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: 1 Print Name: « 4 ` S ` Date: 1 C1 ` Li Day Telephone: S. 3 -3 3 5 . Mailing Address: ��- J IVO I I O"--1 4 O City H:\Applications\Forms-Applications On Line\2014 Applications\Electrical Permit Application Revised 1-1-14.docx Revised. January 2014 bh State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ( ACCOUNT QUANTITY PAID $399.36 EL14-0143 Address: 6000-6198 SOUTHCENTER BLVD Apn: STRT-01453 $399.36 ELECTRICAL $384.00 PLAN CHECK FEE R000.345.832.00.00 $76.80 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 $307.20 TECHNOLOGY FEE $15.36 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R1283 R000.322.900.04.00 $15.36 $399.36 Date Paid: Wednesday, February 19, 2014 Paid By: TOTEM ELECTRIC OF TACOMA INC Pay Method: CHECK 51975 Printed: Wednesday, February 19, 2014 12:06 PM 1 of 1 CR141 TEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: A i el /T, ,/�r7L� �`'� Type of Inspection: "� Address: ' 1000 5_G. gi. Date Called: ^° Special Instructions: Date Wanted: / /O (Q m. (p y Requester: 1 Phone No: ®Approved per applicable codes.Corrections required prior to approval. Jr COMMENTS: - i, Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. 1-ort) PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: K/� ; y Type of Inspection�:jN J� n Address: 6 i � J �� A- - � J� -- E- Date Called: �-- Special Instructions: Date Wanted: a.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: ►IP1eitC k fog A ,- �C- Sav n4 Stir Inspector:' ibrdniek Date: / ac REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO.' CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 thii-ort3 Project: ftelto Type of -Inspection:, ( ": Address: ' Date Called: Special Instructions: Date Wanted: / (a.m. Requester: 111 Phone No: -730 9757 ❑Approved per applicable codes. lJ Corrections required prior to approval. COMMENTS: 90) iii5e 60/1) k 67, 'W6 ,kr.J. ti Inspector: !! fit 4/c Date: 0 cp (ry REINSPECTI©N FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. cI BUIL UMW Mechanical Electrical Plumbing Gas Piping of Tukwila ING DIVISION Call before you Dig. 1-800-424-5555 UNOEA6ROUND SENNCE (USA) SE 1/4, SEC 23, T23 N, R4 E, WM REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review f.es `.-----1Y — — N MATCHUNE STA 11+65 ELECTRICAL ACTIVITIES: 1 C-9NTAAETOR-SHAlk-C-0OROINATEWITH-CFPI-OF4t1KWILMIGNALCONTACiSCOU-SATE3-12 E .BREAKERS IN THE CITY'S SIGNAL SERVICE CABINET AND LABEL -THE BREAKER SLOTS AS-- RR STATION-62ND" AND"RRFB 62ND" RESPECTIVELY, CONTRACTOR SHALL NOTIFY SOOTY BATES TWO WEEKS BEFORE BEGINNING ANY CONSTRUCTION ACTIVITIES AND TO SCHEDULE SERVICE CONNECTION TO THE CITY'S SERVICE CABINET. "`SPLICE RRFB SERVICE-EONDUC-i`ORS-IN EXISTING-JUNETiON-BOX. ELECTRICAL NOTES: 1. TRAY CABLE SHALL BE BLACK, WHITE, GREEN AND DIRECT BURIAL RATED. COMPLIANCE Wj� NFPA 70 NEC, FEB 2 4 2014 I WIRING SCHEDULE RUN N0. CONDUIT SIZE NEW CONDUCTORS REMARKS EX 2" _ 14.. 2" 2`r SPARE EX 2" '4 I6.. PROTECT EXISTING CONDUCTORS A EX4" 146... PROTECT EXISTING CONDUCTORS EX 4" SPARE FILE COPY Permit No. Ll - — D Plan review approval is subject to errors and omissions. tkp roval of construction documents does not authorize the vfoiatan of any adopted code or ordinance. Receipt nt approved Fief and . ,VII II‘•. :I IA 1 owledged: LIO 1f BY Date: 2-- �`Z City Of Tukwila BUILDING DIVISION t LILA RECEIVED CITY OF TUKWILA FEB 1 9 2014 PERMIT CENTER F-LINE RAPIDRIDE STATION 90% ELECTRICAL PLAN CITY OF TUKWILA REVISION BY APP'D DATE 41) BergerABAM 33301 9th Avenue South, Suite 300 Federal Way, Washington 98003-2600 (206) 431-2300 Fax: (206) 431-2250 DKS 719 Second Ave, au9e 1250 Seattle, WashInpten 99104 (206) 3921800 wev dkseseod6Varem concord Aitihb AVp4414001 E10 SEATTLE, WA96104" P14:206.6e20667 DESIDNE11 X. ?HANG DRAWN: A. TULY QItOOD: C. LONG X:tNANG POOJW MNAGU4 S.RAKOWANDERSON AWIW"ED: IBIS NO: WOAKKOLLM OONa crIAR SCAM =10' SRE WCATION MO: ONE INCH AT FULL SIZE If NOT ONE INCH, SCALEACCOROINGLY King County Department of Transportation ZONE 58102 SOUTHCENTER BLVD AND 62ND AVE S DATE: 10/D4/13 PEANII NP DwRMR9acu EL01 WWI ND: OF 14 20 MATCNLINESTA CaII before you Dig. T 1-800-424-5555 UNDERGROUND SERVICE (USA) 74 446 ELECTRICAL WIRING SCHEMATIC FOR INFORMATION ONLY SE 1/4, SEC 23, T23 N, R4 E, WM 21116 286 /I' REVIEWED .FOR COMPLIANCE WITH NFPA 70 4. NEC FEB 2 4 2014 City of.Tukwila BUILDING DIVISION PANEL:58102 VOLTAGE RATING: 120 VOLTS, BUS RATING: 30 AMPS MAIN BREAKER: 30 AMPS FEED: BOTTOM FAULT CURRENT: 1 PHASE, 2 WIRE AMPS AMPS INTERRUPTING CAPACITY: 22,000 CIRCUIT DESCRIPTION VA CKT BRKR TECH PYLON 84 1 1/ 20 SHELTER LIGHTS 169 2 1/ 20 PED LIGHT 100 3 1/ 20 SPACE 4 1/ 20 SPACE S 1/ 20 SPACE 6 SPACE 7 SPACE 8 TOTAL LOAD = 353 VA = 2.94 AMPS AVERAGE ELECTRICAL NOTES: 1. TRAY CABLE SHALL BE BLACK, WHITE, GREEN AND DIRECT BURIAL RATED. ELECTRICALACTNmES: O INSTALL OWNER FURNISHED POWER PEDESTAL AND FOUNDATION, PER KING COUNTY METRO TRANSIT PASSENGER FACILITY STANDARD DETAILS, DRAWING NO. D112, DETAIL 3. THE FRONT DOOR OF THE CABINET SHALL BE ORIENTED AS SHOWN BY `F" ON THE PLANS. KCM TO SUPPLY POWER PEDESTAL. O INSTALL ATYPE 2 JUNCTION BOX AS PER WSDOT STANDARD PLAN J-40.10-02. O INSTALL A 14-FOOT PEDESTRIAN LIGHT POLEAND FOUNDATION. INSTALL A SHOEBOX 100 WATT LED PEDESTRIAN LUMINAIRE. SEE SHEET EL04 DETAIL 1 AND 2 FOR FOUNDATION AND MOUNTING DETAILS. —INSTAi+L rEeHwPYL0N. — RECEIVED CITY OF TUKWILA FEB 19 2014 PERMIT CENTER WIRING SCHEDULE -RUN RUN , CONDUIT 512E NEW CONDUCTORS REMARKS 2 /j1�\y /2\ EX 2" 1 412-3 TC LABEL CONDUCTORS WITH "SHELTER LIGHTS" l a \ 1" 2N12, 812G LABEL CONDUCTORS WITH "TECH PYLON" / S \ 2" IH16. 2" SPARE 76\ EX 2" 016+ PROTECT EXISTING CONDUCTORS B \ 2" 288,88G F-LINE RAPIDRJDE STATION 90% ELECTRICAL PLAN CITY OF TUKWILA Na REVISION 9Y APP'D DATE BergerABAM 33301 9th Avenue South, Suite 300 Federal Way, Washington 98003-2600 (206) 431-2300 Fax: (206) 431-2250 DKS 719 Second Aft $,Ate 12ED Sea91e, Washington 98104 (206)382.9800 v.NN.dksassocIeIes.DOn, 4 concord 7102ND AVENUE, SUITER3O SEATTLE. WA9R304 PH:206.682,0567 xZHANG A TULY CHEMED: C,LONG X MANG RCM=MANAOU: S.RAKOW ANDERSON APPROVER: SCALE 1"=10' 517E LOCATION N0: ONE INCH AT FULL SIZE IF NOT ONE INCH, SCALEACWRDINGLY King County Department of Transportation ZONE 58102 SOUTHCENTER BLVD AND 62ND AVE S DATE: 10/04/13 PERMIT NO: DRAWING N0: ELO2 SNEETNO: OF 15 20 Call before you Dig. 1-800-424-5555 UNDERGROUND SERVICE (USA) SE 1/4, SEC 23, T23 N, R4 E, WM SOUTHCENTER BLVD SIGNAL STANDARD DETAIL CHART PO �� Q "" '1-eCA7 M....,.. —. POLE ' �PPB ORIE FROM NORTH REMARKS (SEE NOTES BELOW) FOUNDATION STATjPN. - OOFFSEi µ 2 ti 1 ` 14+15.11 75.36 t, SEE STANDARD PLAN 1-21.10.02 115' 2 14+26.12 73.76 i 295`-----....,�' • TYPE I FLASHING BEACON POLE PER WSDOT STANDARD PLAN 1-21.16.00. WIRING SCHEDULE RUN 0 N/�. CONDUIT SIZE NEW CONDUCTORS REMARKS / 1 \: Z '44/6.. / 2 \ EX 2' 3MBa No. REVISION BY DATE j BergerABAM 33301 9th Avenue South, Suite 300 Federal Way, Washington 98003-2600 (206) 431-2300 Fax: (206) 431-2250 DKS 719 Second Ave., SU'Re 1250 Seattle, Washington08104 (206)382.9800 o eW.dRassocla186A0n1 concord 710 2N0 AVENUE, SUITE 830 SEATRE. WA 98104 PH:206,.6e2.,0567 D676NED: X. 2HANG DRAWN: A, TULY 1110:a(ED: C. LONG RFCOMMFNOOY X. ZHANG W11-2 W16-7P LEFT OR RIGHT M1 ELECTRICALACTIvmES: Q INSTALL A TYPE 1 JUNCTION BOX AS PER WSDOT STANDARD PLAN 1-40.10-02. INTERCEPT EXISTING CONDUIT AND EXTEND TO NEW JUNCTION BOX. • RNISHAND INSTALt'AiYPE`TF1 SHTNG°BEACO 3SH —ANDINSTALLAT IpEDREGTANGWIAR-RAPIfft0SHI IN THE brr ON TH SSHEET. ELECTRICAL NOTES: 1..—CONTRAGFGR SHALT.-VERIPAT E POEE;;EIGHf IS-ADEQUAYE-FOR-THEIR-PROPOS6D- RECTANGUTAR-RAPID-F174SPRNG-R6ACONSYSTENt.- I L �a CONTROL / BOX; J REVIEWED EO - COMPLIANCE WIT!-t NFPA 70 - NEC FEB 2 4 2014 FRONT VIEW SIDE VIEW FLASHER ASSEMBLY DETAIL SIGNS 30"X3 M 11-2 CD 24"X12" MUTCD Wl6-7P B BUTTON City of Tukwila NG DIVISION HANDHOLE RECEIVED CITY OF TUKWILA FEB 19 2014 PERMIT CENTER F-LINE RAPIDRIDE STATION 90% ELECTRICAL PLAN CITY OF TUKWILA 1,110.1411 : S.RAKOW ANDERSON APPROVEM INS NQ CONT9ACTNO: 1"=10' SUE LOCATION NO; ONE INCH AT FULLSIZE F IF NOT ONE INCH, SCALEACCONDINGLY King County Department of Transportation ZONE 58102 SOUTHCENTER BLVD AND 62ND AVE S 10/04/13 PEPMDNO: DRAWING N4 EL03 1NEETNO: OF 16 20 8 1 Call before you Djg. 1-8Q0-424-5555 u a0 .s ma (US) 3.5" ON HIGH SIDE OF FINISH GRADE 2" PVC CONDUIT SCHEDULE 80 CONCRETE CLASS 3000 1" ON HIGH SIDE OF FINISH GRADE 24"O U_JOINTAT EDGE OF BLOCKOUT 9"0 BOLT CIRCLE HANDHOLE: SET 90' CLOCKWISE FROM CURB COIL 3' OF N4 SOLID BARE COPPER WIRE ABOVE FOUNDATION (UFER GROUND) DEWAU( FINISHED GRADE OF FOUNDATION THROUGH JOINT FOR BLOCKOUT FOUR 4"-10NCx 1'-6"x3"ASTM A307 ANCHOR BOLTS (HOT DIPPED GALVANIZED FULL LENGTH), 2 NUTS, 2 FLAT WASHERS AND 1 LOCK WASHER PER BOLT (HOT DIPPED GALVANIZED). INSTALL UFER GROUND. COIL2 •'.SOLID, COPPER AT BOTTOM OF FOUNDATION. ALUMINUM PED LIGHT FOUNDATION SCALE: NOT TO SCALE 3THREAD PROJECTION ABOVE NUT ANCHOR BOLT HEX NUT LOCK WASHER FLAT WASHER NOTE: GROUT SHALL BE PREMIXED NON -SHRINK AND NON-METALLIC. HEX NUT GROUND LUG & 2 FLAT WASHERS WRAP WITH TAPE TO SEAL OUT GROUT ttttt 2"0 PLASTIC DRAIN TUBE ON LOW SIDE OF FINISH GRADE ALUMINUM PED 1IGHT MOUNTING DETAILS O. 2''. SCALE: NOT TO SCALE i�J METALLREO WARNING TAPE FINAL GRADE CONDUIT(S) OR CABLE AS NEEDED CONDUIT(S) AND CABLE TRENCH DETAIL SCALE: NOTTO SCALE Q 120 VOLT i UTILITY ONE LINE DIAGRAM DETAIL SCALE: NOTTO SCALE SHELTER LIGHTING PEDESTRIAN LIGHT GROUND FAULT RECEPTACLE BRANCH GENERAL NOTES 1, THE DETAILS ARE REFERENCED FROM CIVIL PAVING PLAN SHEETS AND ELECTRICAL PLAN SHEETS. REVIEWED _FOR COMPLIANCE WITH NFPA 70 - NEC FEB 2 4 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 1 9 2014 PERMIT CENTER F-LINE RAPIDRIDE CITY OF TUKWILA STATION 90% ELECTRICAL DETAIL No. REVISION 6Y ARM DATE BergerABAM 33301 9th Avenue South, Suite 300 Federal Way, Washington 98003-2600 (206) 431-2300 Fax: (206) 431-2250 DKS 719 Second Ave„ SW1a 1250 Seattle, Washington 08104. (206)302.9890 WWwmdkeassada1es,mm -***-co n cord : rC Ii.1 710 2ND AVENUE, SURE 830 SEATTLE. WA98104 PH:206.502.0567 DP9GNED: X. ZHANG DRAWN: A,TULY CHECKED: C. LONG REIOMMENDEO: PRm1CT MANAGER: 5. RAKOW ANDERSON APPROVED:.. MIS ND: worx MOMS, 01011ALTNO: SCALE: NTS SITE LOCATION NO: ONE INCH AT FUTA SIZE IF NOT ONE INCH, SCALE.A000RDINGLY King County Department of Transportation ELECTRICAL DETAILS F-LINE RAPIDRIDE DATE. 10/04/13 PERMIT Na DRAWING NO: ELD4 SHEET NO: Or 17 20 City of Tukwila Department of Community Development 10/1/2014 Jim Haggerton, Mayor Jack Pace, Director MIKE SHAFFER 2332 JEFI±RSON AVE TACOMA, WA 98402 RE: Permit No. EL14-0143 KING COUNTY METRO SOUTHCENTER BLVD & 62 AVE S Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/2/2014. Based on the above, you are hereby advised to: 1) Ca11 the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/2/2014, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: EL14-0143 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 IEAMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL14-0143 PROJECT NAME: KING COUNTY METRO DATE: 02/19/2014 SITE ADDRESS: SOUTHCENTER BLVD & 62 AVE S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division ill Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 02/20/14 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Notation: DUE DATE: 03/20/14 Approved with Conditions Denied (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 TOTEM ELECTRIC OF TACOMA 'NC Page 1 of 4 Washington State Department of Labor & Industries TOTEM ELECTRIC OF TACOMA INC Owner or tradesperson JARDEEN, RICHARD E Principals JARDEEN, RICHARD E STEPHENS, JOHN R STEPHENS, MARK A STEPHENS, SCOTT B STEPHENS, JOHN R Doing business as TOTEM ELECTRIC OF TACOMA INC WA UBI No. 278 043 550 PO BOX 1093 TACOMA, WA98401 253-383-5022 PIERCE County Business type Corporation Governing persons JOHNSTEPHENS License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor License specialties GENERAL License no. TOTEMET315BS Effective — expiration 01/10/1969 — 09/30/2015 Active. Meets current requirements. Designated administrator ACTIVE STEPHENS, MARK A License type License no. Electrical Administrator STEPHM*101CC Bond TRAVELERS CAS & SURETY CO $4,000.00 Bond account no. 081 S103483688BCM Received by L&I Effective date 10/31/2000 12/26/2000 Insurance No insurance accounts during the previous 6 year period. Savings No savings accounts during the previous 6 year period. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=278043550&LIC=TOTEMET315BS&SAW= 02/27/2014