Permit EL14-0145 - EDGE CONNEX - DATA CENTER
EDGE CONNEX 3425 S 116 ST STE133 EL14-0145 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No: 1023049043 Permit Number: EL14-0145 Address: 3425 S 116 ST 133 Issue Date: 4/9/2014 Permit Expires On: 10/6/2014 Project Name: EDGE CONNEX Owner: Name: EPROPERTY TAX INC DEPT 207 Address: PO BOX 4900 , SCOTTSDALE, WA, 85261 Contact Person: Name: KIER VONDRUSKA Phone: (206) 654-2137 Address: 1200 SIXTH AVE #500 , SEATTLE, WA, 98101 Contractor: Name: DYNELECTRIC COMPANY Phone: (503) 226-6771 Address: 5711 SW HOOD AVE , PORTLAND, OR, 97239 License No: DYNALC*032KR Expiration Date: 5/19/2015 Lender: Name: Address: 1 / l DESCRIPTION OF WORK: NEW DATA CENTER WITH SERVER RACKS Valuation of single family: $0.00 Valuation of mf/comm: $975,000.00 Type of Work: TENANT IMP Fees Collected: $13,261.24 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer Distric: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2012 2012 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree agree to the conditions attached to this permit. `� Signature: /&oi.e• , Date: 4/- 9 � 7 Print Name: E306erotAhi This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: ..3 l Z,S `j -I 1(p Tenant Name: (aA1X PROPERTTY OWNER Name: Fitt p nTy .T_Ayme_ . zt37 Address: 3yf S ) / up-, 5T City: ftiktAmL� State: /�/4 Zip:,/6jlte, CONTACT PERSON - person receiving all project communication Name: ki i iz Y6/,10 rLtiS [4;rf Address: 'IZcc) s 1, xr.yi1'Z"E `��.-z,0 City: State: Gam, Zip:gm/) / Phone: 20co la S y 'Z 13-) Fax: — Email: lg — \/'( /a )s 601,5/....e. rs King Co Assessor's Tax No.: 10_7 `--e) 1 " q a��z Suite Number: ' -?j 3 Floor: 1 New Tenant: � Yes ❑ ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: Tg ID Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 000 Scope of Work (please provide detailed information): A/E -) Z7/t'T 1 (' /7 fz, �e li ✓ev Will service be altered? ['Yes ❑ No Type of Use: P /Ai CN CR-.. Type of work: ❑ New ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: O Puget Sound Energy ❑ Service Change ❑ Fire Alarm Seattle City Light Adding more than 50 amps? O Remodel O Telecommunication ❑ No ,(Tenant Improvement ❑ Temporary Service H.\Applications\Forms-Applications On Line\2014 Applications\Electrical Permit Application Revised 1-I-14.docx Revised: January 2014 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $65.00 ❑ Temporary service (generator) $80.90 ❑ Manufactured/mobile home service $86.25 (excluding garage or outbuilding) ❑ Carnivals $80.60 Number of concessions $10.80 ea Each ride and generator truck $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: C). Q� Print Name: K 1.12- V5.0 O& Date: Day Telephone: Mailing Address: fl ZO S j A-i 1 57)0 i 1Sl ii1- ; City State 18/DI Zip H:\Applications\Porms-Applications On Line\2014 Applications\Electrical Permit Application Revised 1-1-14.docx Revised: January 2014 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $65.00 $65.00 $65.00 $65.00 $65.00 EL14-0145 ' Address: 3425 S 116 ST 133 Apn: 1023049043 ELECTRICAL ADDITIONAL PLAN REVIEW TOTAL FEES PAID BY RECEIPT: R1854 R000.345.830.00.00 Date Paid: Monday, April 21, 2014 Paid By: DYNALECTRIC Pay Method: CHECK 102577 Printed: Monday, April 21, 2014 8:02 AM 1 of 1 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT I QUANTITY PermitTRAK PAID $21,017.24 D14-0059 Address: 3425 S 116 ST 133 Apn: 1023049043 $3,296.72 DEVELOPMENT $3,199.89 PERMIT FEE R000.322.100.00.00 $1,936.60 PLAN CHECK FEE R000.345.830.00.00 $1,258.79 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $96.83 TECHNOLOGY FEE R000.322.900.04.00 $96.83 EL14-0145 Address: 3425 S 116 ST 133 Apn: 1023049043 $13,261.24 ELECTRICAL $12,751.19 PLAN CHECK FEE R000.345.832.00.00 $2,550.24 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 $10,200.95 TECHNOLOGY FEE $510.05 TECHNOLOGY FEE R000.322.900.04.00 $510.05 M14-0049 Address: 3425 S 116 ST 133 Apn: 1023049043 $4,259.72 MECHANICAL $4,095.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $3,244.20 PLAN CHECK FEE R000.322.102.00.00 $819.18 TECHNOLOGY FEE $163.84 TECHNOLOGY FEE R000.322.900.04.00 $163.84 PG14-0025 Address: 3425 S 116 ST 133 Apn: 1023049043 $199.56 PLUMBING $191.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $121.00 PLAN CHECK FEE R000.322.103.00.00 $38.38 TECHNOLOGY FEE $7.68 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R1291 R000.322.900.04.00 $7.68 $21,017.24 Date Paid: Thursday, February 20, 2014 Paid By: BURR COMPUTER ENVIRONMENTS Pay Method: CHECK 9321 Printed: Thursday, February 20, 2014 10:45 AM 1 of 1 SYSTEMS I INSPECTION NO. INSPECTION RECORD Retain a copy with permit 611(- °Plc PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 „ Project: rb ke i r � �N,45c Type of Inspection: Address: fit/is` Date Called: Special Instructions: Date Wanted: / atm.." 13. Requester: Phone No: VgApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: n 1 61, t )41 Inspector: Date: 0 1/ry REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: tt) 4t- Cp#,fisitxoditt4 Type of Inspection: ri Address: 3125- 5. 1/6 Ir. Date Called: Special Instructions: Date Wanted: VIc ap m Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: il L4 y 4 t, ' G 1k I44 4904k. --PokoveA1itoV r -- (ihi(v,4 14 eoli Par e Inspector: AlfstAkeN Date: of t 511 y r REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (2.06) 431-2451 to-i-ofyc, Project: ,. if Type of Inspection: tha- Address: 3 c5 ` i fa ! Date Called: Special Instructions: Date Wanted: 7/0 a.m., le„„,..11. Requester: Phone No: 4Approved per applicable codes. Corrections required prior to approval. COMMENTS: ni/ u,.,. 44,A. PANIA-5 , ( I6& ToN5 j (JP5 Inspector: Date: 0rio kit 2 Y j REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431-2451 /Z INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-367 Project: ib4 ( �rP �! �j;7� Type of Inspection: moo._ ` (CX Address: ,_ • I Sj- Date Called: Special Instructions: Date Wanted: thif a.m? Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: rK rt 1 A (1 \ ` — f4 IV Cc` . AS t-4 rt . r410.1(..1 ? -I r 1 - kpL, ck41.,- i6brs CYY r c-t- (crk ext_� Roo �.I�i) i� Jat'C�, t l ii(.kiA �1 1`[��,.�)j Inspector: 4164flipieizs, Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. I( INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 6.14- ON( Project: ( - ,=,�l e ��t Type of Inspection: t �! t{ /N Address: i is / �/r✓/ �' Date Called: Special Instructions: Date Wanted:WO/ a.m.; Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 6(41(Cgt. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. Inspector: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: � � � �A� Type of Inspection: �� ✓K.0 C Address: 3`/zS S - No 5F Date Called: _. Special Instructions: Date Wanted: 7 3 j ('"a.m' `fs"t�'i'. Requester. Phone No: 1 S l b oApproved per applicable codes. tl Corrections required prior to approval. COMMENTS: a - (1 4(. ffi.74to 5 A-,o -7F.'r •" (7)/i`4 t ze sJl until tteititiAiq (Ai/kr Inspector: Date: b 7/ 3 / REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. i 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431-2451 INSPECTION'RECORD �iy,�,j Retain a copy with permit G "1 " Oit5. INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 Project: 6�rT `v( e Type of Inspection: et Address: Date Called: Special Instructions: Date Wanted: it 30 a Requester: Phone No: 1_03 57 rt 0$74. Approved per applicable codes. BoCorrections required prior to approval. COMMENTS: i. eoivri<4r 0,44 Woes- limit 7t_a CpAb & Inspector: Date: 07 30 v t. Ilr REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. N\A\kc INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING D 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431-2451 PERMIT NO. �LI- Or'f$ IVISION (206) 431-3670 Project: ► 6 (',j Type of Inspection' ilivirxr 4 b‘it\10 Address: ,1Z(..flG cr.. Date Called: t ` Special Instructions: Date Wanted: // p.m._ Requester: f Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: I/ 1 t r / Y/ .. rI - _ 664j M Pert) Inspector: .,•- /. 'ciJric .,_ Date: egi 3o by ��►r I 1 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 7 INSPECTION RECORD ti/fq-NYC- PERMITRetain a copy with permit INSPECTION NO. NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: �rt Type of Inspection: Address: % Date Called: Special Instructions: Date Wanted: a.m.: 6/17 Requester: Phone No: 503 7 r Z oc 7L DApproved per applicable codes. Corrections required prior to approval. COMMENTS: Al°1V1-4- V � Ott., vJ"rw5 o` Inspector: Date: 0//2.7 j1, REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Ito INSPECTION -RECORD Retain a copy with permit INSPECTION NO. ERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project:cr)l� �G�l/rn c Type of Inspection: fQ.G ea v^l 0 .. Address: 311ZS5- it(,, s- Date Called: --. Special Instructions: Date Wanted: _405 m. Requester: tttttt Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: l c) tl %-r1 - Lid LP i^04c t(ML Inspector: 64 2-dri REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 (LH- 0 I ki Project: act(6AiNex- Type of Inspection. KO At+ ) Address: 3,12 S•'/l / S` . Date Called: Special Instructions: Date Wanted: ! //(0 a..- Requester: Phone No: C$3 511 oV(0 Approved per applicable codes. t�J Corrections required prior to approval. COMMENTS: r) v Aia6ertiV mkt,, 4 y r,./6 Inspector:%'"/ /6 64/67\ Date: hfrif, I JJJ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. r INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: i i.,�n/n� ! r Type of Inspection: %_ , (.4- In// 19 ,�C� Address: Date Called: Special Instructions: #(33 Date Wanted: %f(lf a.r p.m. Requester: ' Phone Now 5 7 05143 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ek r, f U - , - t,f,I�{-Q,�(,t,DJi''�I, $ tJJc ,.. --- tAbori {./ Cz tJ A-5 i 4-(l t rkt t cttf-r ,°" ?f"V 4L. 0 ( Inspector: r Date: DO REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Calf to schedule reinspection. �J 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 43'���O��j INSPECTION' RECORD -367P J Retain a copy with permit O'J/f INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Permit Inspection Request Line (206) 431-2451 Project: 6 / _ ` kl4YJV` Type of Inspection: !)� , ` lY� Yt t Address: 3y2 5 51' 1 Sr - Date Called: Special Instructions:/3 Date Wanted: jD� a-m: Requester: f Phone No: 5-63 01 D 574 Approved per applicable codes. I] Corrections required prior to approval. COMMENTS: s1 — 401.01 Inspector: "`/ Date: DC 07/ r t r REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: ,i 4 CV Type of Inspection:AX cktl)! ko vAl M y Address: " 3rz-S"s Msr- Date Called: Special Instructions t� /i3 /SS Date Wanted: 5 /��7 a.m.:- (p'''m; Requester: Requester: ► Phone No: co3 S iL 05 7( Approved per applicable codes. Corrections required prior to approval. i COMMENTS: u1NIPG'eclrC Inspector: r Od Date: ' i L� I I REINSPECTI©N FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 5outhcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. lt. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: fbE6J� Type of inspecti 1 i4)kX Address: 3112,5--S 4 sr- Date Called: oSpecial Instructions: tt Date Wanted: 514 Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: OVA { () �, U - - C6/6k T F.6). t�R, . 2- 1,oc,1-(QAi5 Inspector: Date: vS/Zr (y REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Cal! to schedule reinspection. Lighting, Motor, an ' ansformer Permit Docum: . Checklist LTG-CHK 2012 Washington State Energy Code Compliance I-.,..,6 for Commercial Buildings including R2 & R3 over 3 stories and all t. , Project Address 3425 S. 116th Street Date Revised Jan 2014 4/9/2014 • The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes LIGHTING CONTROLS (Section C405.2) Yes C405.2.1.1 C405.2.1.2 Manual interior lighting controls Indicate on plans the manual control type & locations served; Sheet E2.2 Indicate of plans the 50% lighting load reduction method Sheet E2.2 provided or identify exception taken NA C405.2.2.1 Automatic time switch controls and override switching Indicate lighting system automatic shut-off capability - identify lighting zone areas served on plans; Indicate locations of override switches on plans and the areas served, include area sq. ft.; Indicate locations where automatic shutoff is prc tecttlytN&W " methods (occupancy sensor, daylight controls, etc) ILE C PY ...ewe Yes C405.2.2.2 Occupancy sensors Indicate on plans the locations served by occupancy sensors Sheet E2.2 NA NA C405.2.2.3 C405.2.2.3.2 Daylight zones - Vertical fenestration and skylights Daylight zone controls Indicate vertical fenestration primary and secondary daylight zone areas on plans, include sq. ft.; Indicate skylight daylight zone areas on plans, include sq. ft. Indicate on plans the locations served by daylight zone controls; Indicate in plans the lighting load reduction (dimming) method - stepped or continuous dimming NA NA C405.2.3 C405.2.3 - Items 1&2 Specific application lighting controls - General Display and accent lighting Indicate on plans the locations served by specific application lighting controls Indicate lighting control method for display and accent lighting, and display case lighting; KtVI WIL7.FUR COMPL ANCE WIT NFP 70- NEC Indicate these fixtures are controlled independently from both general area lighting and other lighting applications within the same space APR 17 2014 NA C405.2.3 - Item 3 Hotel/motel guest rooms Provide a lighting control device at each guest room entry for all permanently installed fixtures in guest room; Indicated whether lighting control is manual or automatic NA NA NA Yes C405.2.3 - Item 4 C405.2.3 - Item 5 C405.2.3 - Item 6 C405.2.3 - Item 7 Supplemental task lighting Lighting for non - visual applications Lighting equipment for sale or demonstration Means of egress lighting Provide automatic shut-off vacancy controls for supplemental task lighting, including under -shelf or under -cabinet lighting Identify eligible non -visual applications and method of lighting control; Indicate these fixtures are controlled independently from both general area lighting and other lighting applications within the same space Indicate lighting control method for lighting equipment for sale or demonstration; Indicate these fixtures are controlled independently from both general area lighting and other lighting applications within the same space BUILDIN DIVISIO If egress lighting power density is greater than 0.05W/ft2, indicate method of automatic shut-off during unoccupied N/A periods; and emergency means of egress illumination Sheet E2.2 Identify on plans the egress fixtures that function as both normal JVF *ITV OF TUK ILA APR 1 1 20 4 NA C405.10 C405.11 Cooler and freezer lighting Provide vacancy device or timer to turn off fixtures within 15 minutes of unoccupancy for cooler and freezer lighting fixtures with lamp efficacy less than 40 lumens per watt °ERMIT CEN E = Yes C405.2.4 Exterior lighting controls method and locations served Indicate on exterior lighting plans the automatic lighting control Sheet E2.2 NA Yes C405.6.1 C408.3 Exterior building grounds lighting controls Lighting system functional testing Provide motion sensor controls for building grounds fixtures rated at greater than 100 watts with lamp efficacy less than 60 lumens, or identify exception taken I� Identify applicable commissioning documentation requirements IA per Section C408 or eligibility for exception; Provide written procedures for functional testing of all automatic controls and describe the expected system response; Mai V N0._L Identify in construction documents the party responsible for functional testing of automatic lighting controls Sheet E0.1 INTERIOR LIGHTING POWER & EFFICACY (Sections C405.5, C405.10, C405.11) rated watts per fixture; Sheet E4.1 Provide fixture schedule with fixture types, lamps, ballasts, and !`A !IC C 4 �LI�1- 0...(L 1/01111110 Lighting, Motor, and -ansformer Permit Docume'—Checklist LTG-CHK 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R Revised Jan 2014 Project Address 3425 S. 116th Street Date 4/9/2014 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes Yes l'YVJ.J. , C405.5.1.1 C405.5.1.2 C405.5.1.3 C405.5.1.4 Total connected interior li htin 9 g power Identifyspaces eligible for lighting p g� g g power exemption on plans and in compliance forms; N/A - Identify lighting equipment eligible for exemption in fixture schedule and in compliance forms; NIA Indicate that exempt lighting equipment is in addition to general area lighting and is controlled independently N/A Yes C405.4 Exit signs Provide exit sign types and rated watts per fixture in fixture schedule (maximum 5 watts per fixture) Sheet E4.1 NA C405.10 C405.11 Cooler and freezer lighting For lighting in walk-in coolers and freezers, and refrigerated warehouse coolers and freezers, provide rated lamp efficacy (in lumens per watt) in fixture schedule NIA Lighting Power Calculation - Indicate compliance path taken Yes C405.5.2 Building Area Method Complete required compliance forms — proposed wattage per building area does not exceed maximum allowed wattage per building area. Identify locations of building areas on plans NA C405.5.2 Space -By -Space Method Complete required compliance forms — total proposed wattage does not exceed maximum allowed wattage. Identify locations of space types on plans, including retail display areas as applicable EXTERIOR LIGHTING POWER & EFFICACY (Section C405.6) Yes C405.6.2 Total connected exterior lighting power Provide fixture schedule with fixture types, lamps, ballasts, and rated watts per fixture; Identify exterior applications eligible for lighting power exemption on plans and in compliance forms; Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting Yes Table C405.6.2(1) Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ NA C405.6.1 Exterior building grounds lighting For building grounds fixtures rated at greater than 100 watts, provide rated lamp efficacy (in lumens per watt) in fixture schedule Yes C405.6.2 Exterior lighting power calculations Complete required compliance form — proposed wattage for exterior lighting plus base site allowed does not exceed maximum allowed MOTORS & TRANSFORMERS (Sections C405.8, C405.9) NA C405.8 Electric Motors For motors not part of an HVAC system, provide electric motor schedule on electrical plans with hp, rpm, and rated efficiency Yes C405.9 Transformers Provide distribution transformer schedule on electrical plans with transformer size and efficiency Sheet E1.1 no" is selected for any question,provide explanation: Exterior Lighting c mmary LTG-EXT 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 s ories and all R1 Revised Jan 2014 Project Info Project Address: 3425 S. 116th Street Date 4/9/2014 Tukwila, WA 98168 For Building Department Use Applicant Name: Burr Computer Environments, ATTN: Walter N Applicant Addr: 10400 Rodgers Road, houston, TX 77070 Applicant Phone: 281-374-8644 Project Description ■ New Building t, Addition • Alteration ■ Plans included Lighting Zone As specified by jurisdiction. Zone selection required to enable LTG-EXT 0 Zone 1 • Zone 2 CI Zone 3 0 Zone 4 turn, Compliance Option 0 Lighting Power Density Calculations 0 Total Building Performance Building Grounds Applies to luminaires> 100 Watts sensor • Efficacy> 60 lumens/W ■ Controlled by motion ■ Exemption (list) Exterior Lighting Alterations • No changes are being made to the existing exterior lighting r New wiring installed to serve added fixtures and/or fixtures relocated to new circuit controls per C405.2.4 and commissioning per Provide applicable exterior lighting Tradable Maximum Allowed Lighting Wattage Base Site Allowance: 600 Tradable Surfaces Surface Description Hnowea vvatts per ft2 or per If Area (ft ), perimeter (If) or # of items Auowea warts x ft2 (or x If) Main Entry Door 20W/LF door width 3 60 Other Entry Door 20W/LF door width 3 60 Other Entry Door 20W/LF door width 3 60 Other Entry Door 20W/LF door width 3 60 Other Entry Door 20W/LF door width 3 60 Other Entry Door 20W/LF door width 3 60 Grounds Walkways >10' wide Mechanical yard 0.14 W/ft2 2785 390 Total Allowed Tradable Watts: 750 raaal)le Yroposea Llgntmg Wattage(Use mfgr listed maximum input vtettage for luminaire.) Tradable Surface Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Main Entry Door Type JE 1 3 3 Other Entry Door Type JE 5 3 15 Grounds Walkways >10' wide Type G 4 54 216 Total proposed tradable twits may not exceed the sum of total alloyed tradable Total Proposed Tradable Watts: tnetts plus the base site allotnence. Any base site allotnence not needed to 234 make tradable mitts comply can be applied to individual non -tradable Non -Tradable Maximum Allowed Lighting Wattage Base Site Allowance Remaining: 600 Non -Tradable Surfaces Surface Description Allowed Watts per ft2 or per If Area (ft2), perimeter (If) or # of items Allowed Watts x ft2 (or x If) Non -Tradable Proposed Lighting Wattage Non -Tradable Surface Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Non -tradable proposed watts may not exceed allovved mitts for any individual . surface unless the total excess mitts for all non -tradable surfaces are less than the remaining site allovvence. Total excess Non -Tradable watts: 0 Site Allowance Balance: 600 Exterior Lighting COMPLIES WITH SITE ALLOWANCE Interior Lighting S, imary LTG -SUM 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stones and all R1 Revised Jan 2014 Project Info Compliance forms do not require a to pasuse. Instructional and calculating cells are write- Project Address 3425 S. 116th Street Date 4/9/2014 Tukwila, WA 98168 For Building Department Use Applicant Applicant Name: Burr Computer Environments, ATTN: Walter Moore Applicant Address: 10400 Rodgers Road, houston,TX 77070 9 Applicant Phone: 281-374-8644 Project Description • New Building • Addition F Alteration t. Plans Induded Lighting Compliance Path • Lighting Power Density Calculations 0 Total Building Performance (If Total Building Performance then only LGT-CHK is Lighting Power Allowance Method Selection required to enable LPA forms ly Building Area Method 0 Space -By -Space Method Interior Lighting System Description Briefly describe lighting system type and features. Lighting for mechaincal rooms, electrical rooms, corridors, storage rooms and data center. Controls are manual and by occupancy sensors. Exterior lighting is controlled by photocell. Additions and Change of Space Use (C101.4.3 & C101.4.4) T Addition area or Change of Space Use area complies with all applicable provisions as stand alone project is combined with existing building lighting systems to demonstrate compliance with all applicable C101.4.3 Area Method (LTG-INT-BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document allowed and proposed (including existing if applicable) lighting wattage of Addition or Change of Use space. Provide lighting controls per C405.2 and commissioning of lighting controls per C405.13. • Addition area provisions per Provide Building maximum applicable Alterations, Renovations and Repairs (C101.4.3.1) t: 60% or more of luminaires in space replaced Area Method (LTG-INT-BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document allowed Kettage within the lighting retrofit space in Maximum Allowed Wattage table and proposed (including existing) in Proposed Wattage table. Retrofit and non -retrofit spaces shall be documented separately using multiple forms. Provide Building maximum lighting wattage • Less than 60% of luminaires in space replaced Space -By -Space Method (LTG-INT-SPACE) Compliance Form for this retrofit area. Document existing total the lighting retrofit space in cell provided in the Maximum Allowed Wattage table. Document proposed (including wattage in the Proposed Wattage table. Provide a separate wattage within existing) lighting • Lamp and/or ballast replacement within existing luminaires only — existing total interior building wattage not increased n New wiring installed to serve added fixtures and/or fixtures relocated to new circuit manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific controls (C405.2.3), and commissioning of lighting controls per C405.13 Provide applicable application • New or moved lighting panel applicable lighting controls as noted for New Wiring, automatic time switch controls (C405.2.2.1), and commissioning of per C405.13. Provide all lighting controls - luminaires unchanged or moved only applicable lighting controls as noted for NewWiring and commissioning of lighting controls per C405.13. • Space is reconfigured Provide all • No changes are being made to the interior lighting and space use not changed. Interior Lighting St., ..,imary - Building Area M, 'god LTG-INT-BLD 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Address 3425 S. 116th Street Date 4/9/2014 Lighting Alterations, Renovations & Building Additions 0 Less than 60% 0 60% or more 0 Stand alone 0 Addition fixtures replaced fixtures bldg. addition combined Notes: a. Lighting fixtures in a building addition may comply as a stand alone project, or they maybe combined wth the overall existing bldg lighting to demonstrate compliance. Refer to C 101.4.3. b. For retrofits and building additions, provide Building Area types and gross interior areas in the Maximum Allotted Lighting table. If a builidng addition Mill comply as combined wth the overall existing builidng, include all applicable existing Building Area types and gross interior areas. c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. d. If less than 60% of existing fixtures mill be replaced, use LTG-INT-SPACE form. For Building Department Use Maximum Allowed Lighting Wattage Building Area* Location (plan #, room #, or ALL) Area Description Hllowea Watts per ft2 Lross Intenor Area in ft2 watts Hllowea (watts/ft2 x area) Office Sheet E2.2 0. 90 14407 12966 * Select Table C405.5.2(1) Building Area from drop dowi menu. Total 14407 I Proposed Lighting Wattage Building Area* Location (plan #, room #) Fixture Description** Number of Fixtures Watts/ Fixture Watts Proposed Office Sheet E2.2, E4.1 Type A wall mounted LED strip 14 14 196 Office Sheet E2.2, E4.1 Type AE wall mounted LED strip 11 14 154 Office Sheet E2.2, E4.1 Type B LED strip 15 107 1605 Office Sheet E2.2, E4.1 Type BE LED strip 15 107 1605 Office Sheet E2.2, E4.1 Type C LED 2x2 19 35 665 Office Sheet E2.2, E4.1 Type CE LED 2x2 9 35 315 Office Sheet E2.2, E4.1 Type H8 led strip 24 107 2568 Office Sheet E2.2, E4.1 Type H8E led strip 17 107 1819 Office Sheet E2.2, E4.1 Type X 14 4 56 * Select Table C405.5.2(1) Building Area from drop doer menu. ** Include existing to remain lighting and exempt lighting equipment per notes below Compliance by Building Area Building Area Warnings Total Allowed Watts Total Proposed Watts hterior Lighting Power Allowance Office 12966 8983 COMPLIES Total Notes: 1. Proposed Wattage for each Building Area type shall not exceed the Allotted Wattage for that Building Area type. Trading vtettage betvteen Building Area types is not allotted under the Building Area Method compliance path. 2. Proposed fixtures must be listed in the building area in Mich they occur. Include ALL proposed lighting fixtures. 3. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 4. For proposed Watts/Fixture, use manufacturer's listed maximum inputvtettage of the fixture (not simply the lamp vtettage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire eettage or length of track multiplied by 50, 12966 8983 �RMIT COORD COPY .0 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL14-0145 DATE: 04/11/2014 PROJECT NAME: EDGE CONNEX SITE ADDRESS: 63425 S 116 ST, STE 113 Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued X Revision # 1 after Permit Issued DEPARTMENTS: Building Division Building Division Public Works U Fire Prevention Structural Planning Division Permit Coordinator n n PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 04/15/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 05/13/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 1EAMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL14-0145 DATE: 02/20/2014 PROJECT NAME: EDGE CONNEX SITE ADDRESS: 3425 S 116 ST, STE 133 X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Bui ding Division Public Works ■ Fire Prevention Planning Division n Structural Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 02/25/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: 03/25/14 Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL 1 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 04/ 11 /2014 Plan Check/Permit Number: EL14-0145 Response to Incomplete Letter # Response to Correction Letter # j Revision # 1 after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: EDGE CONNEX Project Address: 3425 S 116TH ST SUITE #113 Contact Person: KEIR VONDRUSKA Summary of Revision: Phone Number: (206) 654-2137 Electrically, the design concept remains the same with four legs of distribution. However, each UPS increased in capacity to 500kW. This also required an increase in the total cooling that would be needed upon full usage of the UPS power. The resulting electrical service increased in size to a 4,000A service at 480Y/277V, 3-Phase, 4-Wire to accommodate the larger UPS and cooling loads. And, finally, the planned maximum number of 600kW generators increased to six (6) to support these loads. However, only two (2) generators will be installed as part of this project. ON liSCEND OF wont,* APR 112014 MVP cam Sheet Number(s): E2.3, E2.4, E2.5, E3.4, E4.1, E4.2 "Cloud" or highlight all areas of revision including date of revisio Received at the City of Tukwila Permit Center by: Entered in Permits Plus on H:\Applications\Forms-Applications On Line\2010 Applications \7-2010 - Revision Submittal.doc Revised: May 2011 PROJECT NAME: f DC/6 C PERMIT NO: UIU 0 kL SITE ADDRESS: 9L kV S I L9 5 ORIGINAL ISSUE DATE: l 01 REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS I 1 tk LI W eir2- rr,, AA- 1---,..--- Li Summary of Revision: 11•i(, EIr Ue, (r' ka1 l Tv SD0 JF W IRU 1 G �- GG \c Ill, c.0 12VA C To 4000 A e 4t o `f 1211 v I IJ fV, Lv) & P MIA Received by: _ i„ J „ i t,,_ ,-. REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) DYNALECTRIC COMPANY Page 1 of 3 0 Washington State Department of Labor & Industries DYNALECTRIC COMPANY Owner or tradesperson LEVY, JEFFREY M Principals LEVY, JEFFREY M WARGA, JOHN E JR MCCORMICK, JOSEPH C DAVENPORT, WILLIAM B PRENTICE-HALL Doing business as DYNALECTRIC COMPANY WA UBI No. 601 838 838 5711 SW HOOD AVE PORTLAND, OR97239 503-226-6771 Business type Corporation Governing persons INC JWP JOHN E JR WARGA; JOSEPH C MCCORMICK; LARRY C BROOKSHIRE; PAUL F RARDIN; License Verify the contractors active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. DYNALC*032KR Effective — expiration 05/19/1997 — 05/19/2015 Designated administrator RYDING, EDWARD H License type Master Electrician Bond Active. Meets current requirements. License no. RYDINEH960NU SEABOARD INS CO $4,000.00 Bond account no. 35955197 Effective date 04/01/1997 Insurance No insurance accounts during the previous 6 year period. Savings No savings accounts during the previous 6 year period. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601838838&LIC=DYNALC*032KR&SAW= 04/09/2014 NEW UTILITY �-� TRANSFORMER O3000kVA 480Y/277V SECONDARY (0002) UTILITY METERING CABINET 480Y/277V, 30, 4W, 4000A, 100KAIC, N3R, SE RATED PER UTILITY STANDARDS OTIUTY METER 0.F.C.I. 1 1 TVSS 4000AF 3600AT • 100% LSIG �n MAIN SWITCHBOARD 'MSB01000' 480Y/277V, 30, 4W, 4000A, SE RATED, N1, 100KAIC =N TVSS ;1600AT 1600AF 100% L - LSIG 0.F.C.I. OPT. STANDBY 600kW/750KVA GENERATOR GEN01000 480Y/277V, 30, 4W, 0.80PF (FUTURE) 2 3 4 -• -op L_< LSIG O 001 ) (002) (003) 1600AF ,I,,, 1600AF . 1600AF 1600AT [GFP ]- 1600AT [GFPE�- -,' 1600AT • 100% Ti "" 100% T , 100% L- LSIG L- LSIG -I-' ti --I r O O 0. F.C.I. 1000/3 ) 100% I (soot) O O OPT. STANDBY 600kW/750KVA 550kW GENERATOR GEN02000 480Y/277V, 30, 4W, 0.80PF FUT. OPT. STANDBY 600kW/750KVA 1000/3 ) GENERATOR GEN03000 100% 480Y/277V, 30, 4W, 0.80PF 0.F.C.I. O GENERATOR SWBD 'GSB01 000' 480/277V, 30, 4W, 4000A, 65KAIC FUTURE NSS (FUTURE) 0.F.C.I. 240kA +►.. 1600AF �T]-11600AT M" 100% L LSIG -r< ( FUT. 1 --T-- L_ r • • 1 550kW 1 , ■ 1 FUT. OPT. STANDBY 600kW/750KVA GENERATOR GEN04000 480Y/27N, 30, 4W, 0.80PF 1000/3.1 100% •- 5003 r L 550kW S004 • \1 • 550kW ;. 1 , -1- 1 ■ 1000/3 • l 100% (5005) FUT. OPT. STAN C4 BY 600kW/750KVA GENERATOR GEN05000 480Y/277V, 30, 4W, 0.80PF FUT. OPT. STANDBY 600kW/750KVA GENERATOR GEN06000 480Y/277V 30, 4W, 0.80PF r , 1 1 I 550kW 1 , • O 1 , 1 1000/3 I 100% •- GENERATOR SWBD 'GSB02000' 480/277V, 30, 4W, 4000A, 65KAIC l • 1600AF ) 1600AT 100% -� LSIG (S007) 0.F.C.I. ( 004 AUTOMATIC TRANSFER SWITCH 'ATSA1000' 1600A, 480V 3-POLE, 3-WIRE, 100KAIC OPEN TRANSITION MAIN DIST. SWITCHBOARD 'MDSA1000' 1600A, 480V, 30, 3W, 65KAIC • IN 800AF 800AT 80% 1 I LSIG Tio 1,1200AF •V 900AT 80% L { LSIG 0.F.C.I. 3. az L 800AF •� 800AT 80% LSIG gio j •)800AF 800AT 80% L 1 LSIG ( 005 ) 006) (007) (008 ) L -( FUT. )- -( FUT. 1- L 900AF •) 900AT100% I LSI 900AF 900AF •)900AT �) 900AT / 100% / 100% I LSI I LSI 900AF 900AT 100% LSI 900AF 900AF 900AT )900AT 100% 100% LSI 1 LSI 1 r 4000AF )4000AT LSI N.O. --(5009)- I4000/3 •) LSI SPARE (LOAD BANK) 900AF 900AF )900AT •� 900AT I100% 100% LSI I LSI 900AF 900AT 100% LSI 900AF 900AT 100% LSI 900AF = 900AF 900AT •) 900AT 100% 100% LSI 1 LSI TVSS 240kA 1) • 0.F.C.I. j 1600AF 1600AT • 100% L -� LSIG (SO 08) 0.F.C.I. ( 013 AUTOMATIC TRANSFER SWITCH 'ATSB 1000' 1600A, 480V 3-POLE, 3-WIRE, 100KAIC OPEN TRANSITION MAIN DIST. SWITCHBOARD 'MDSB1000' 1600A, 480V, 30, 3W, 65KAIC 0.F.C.I. 800AF •� 800AT 80% LIN< LSIG 1200AF •j 900AT 80% L z{ LSIG 800AF •� 800AT 80% L.. LSIG Egg 800AF •� 800AT 80% LIN< LSIG ( 014 ( 015 ( 016 017 r-4 1 L w\ • • • --' FUT. AUTO. TRANSFER SWITCH 'ATSC1000' 0.F.C.I. ; 1600A, 480V 3-POLE, 3-WIRE, 100KAIC FUT. ) OPEN TRANSITION FUT. MAIN DIST. r j►1, SWITCHBOARD 'MDSC1000' 1600A, 480V, 30, 3W, 65KAIC 800AF C-PT�-4, 800AT 80% L - C LSIG 1✓ .1 ( FUT. ) 2 r,.. 800AF CGT�M 800AT T i M 900AT I 80% I i 80% L LSIG L -III-G LSIG I I I 6 I [0.F.C.1.1 3 4 I. 1200AF ;is800AF C��g-N 800AT 80% LSIG SPARE ( FUT. ) ( FUT. ) • • M FUT. AUTO. TRANSFER SWITCH 'ATSD1000' FO.F.C.11 1600A, 480V Ja 3-POLE, 3 WIRE, 100KAIC ( FUT. 1 OPEN TRANSITION FUT. MAIN DIST. SWITCHBOARD 'MDSD1000' 1600A, 480V, 30, 3W, 65KAIC 880000ATAF T M" 80% L � LSIG I 1 ( FUT. ) 2 1800AF800AT C�T,Er�; I I 80% L- LSIG L ( FUT. ) `O.F.C.I.1 .3 4 +p11200AF �,� 800AF GFf -- 900AT COTS-N 800AT I ; 80% I 80% L LSIG ' LSIG - SPARE ( FUT. ) SEPARATE PERMIT REQUIRED FOR: Ertrechanical CJ Electrical iirPlumbing Rees Piping City of Tukwila BUILDING DIVISION (FUTURE) •..T... 1600AF �T}- 1600AT 100% LSIG T' I I f _-1-_ ( FUT. 1 J 0.F.C.I. KK 800A/3P 1 . (010 009 \ 800A/3P N.O. STATIC UPS SYSTEM 'UPSA1000' 500kVA/500kW, 1.0pf 480V, 30, 3W, INPUT 480V, 30, 3W OUTPUT 0.F.C.I. 1G ( 011 )06 (B001) (B003) (B002) 800A/3P • N.C. C• 2 KK 800A j 800A )3P •)3P (012) (047) ,.., h y li y 11 g MAINTENANCE BYPASS CABINET 'M'BCA1000' 800A, 480V, 30, 3W 0.F.C.I. KK 018 800A/3P N.C. 800A/3P N.O. (019 STATIC UPS SYSTEM 'UPSB1000' 500kVA/500kW, 1.0pf 480V, 30, 3W, INPUT. 480V, 30, 3W OUTPUT 0.F.C.I. Ir4 -rG ( 020) O (B00 800A/3P N.C. KK 800A jl 800A ) 3P ) 3P ( 021 049 4) ( BOO 6) (B005) 6 g is MAINTENANCE BYPASS CABINET 'MBCB1000' 800A, 480V, 30, 3W (\ FUT. ) L____ L 800A/3P N.C. ▪ 0--4 s --• " • • I r--� 41'‘ 800A/3P ( FUT. K KJ M � N.O. 1. 1 FUTURE STATIC UPS SYSTEM 'UPSC1000' 500kVA/500kW, 1.0pf 480V, 30, 3W, INPUT 480V, 30, 3W OUTPUT • dr. 1 1 w L=T�I z Fiqm icn ▪ YE rs LTA T I J L I T (\ FUT. ) 800A/3P N.C. \so r--1 KK 4 1 r ( FUT. ) r - ( FUT. 1 L _ FUT. MAINTENANCE BYPASS CABINET 'MBCC1000' 800A, 480V, 30, 3W 1F L 800A/3P 1 r--� e'1800A/3P' KKJso) N.O. • .I V ,-,N.C. IJ ( FUT. ) 1. r11 I I 1 1 T I T (\ FUT. ) i-, 800A/3P A.' N.C. .,M r--1 KKi 4 r ( FUT. ) FUTURE STATIC UPS SYSTEM 'UPSD1000' 500kVA/500kW, 1.0pf 480V, 30, 3W, INPUT 480V, 30, 3W OUTPUT REVISIONS No changes shalt be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 1 J 1 I 1 1 1 J I I ( FUT. ) ( FUT. ) FUT. MAINTENANCE BYPASS CABINET 'MBCD1000' 800A, 480V, 30, 3W 0.F.C.I. n 800A •1 3P PDU 'PDUA1000' 500kVA, 480V, 30, 3W INPUT 208Y/120V, 30, 4W OUTPUT 98.36% EFF. 3 7 / 450AT •/ 450AT `) 450AT 600AF`/ 450AT +) 450AT 600AF+) 450AT •) 450AT •) 450AT 3P 3P 3P 3P 3P 3P 3P 3P (0 2)(0 3)(0 4)(0 5)(0 2)(0 2) 0.F.C.I. u u u u 1 I 1 1 ( FUT. )( FUT. )( FUT. )( FUT. ) /\ /\ `\ / ).. A\ <A3;> <A4> <A5> <A6;> RPP 'RPP01000 0.F.C.I. RPP 'RPP02000 225A 225AI 3P 3P. 80% 80% PANEL RPPO1A0' 42 POLE PANEL RPPO1A02 42 POLE 225A 1 225A i)80% P 0 %% PANEL 2PPO1B0; 42 POLE PANEL 2PPO1B04 42 POLE 225A;225/ 3P 3P 80% 80% PANEL RPPO2C01 42 POLE PANEL 2PPO2C0'e 42 POLE 225A 3P 80% 225A 3P - 80%. PANEL 2PPO2D02 42 POLE PANEL 2PPO2D04 42 POLE <B4;> FUT. <C4;> Y RPP \Y I'RPP09000' _-1--1 _ -1 _ _ -ter 1 I 1 1' 225A - 1225AI ; 225A - I 225A, I I 225A 1 2251 I 225A 1 225A 0.F.C.I. r 0.F.C.I. <A4\, FUT. <'D4\> \Y RPP \Y/ I'RPP09000' I J''13P 4`13P 'I's 3P 4' 3P 80% • 80% r-J__7r-J--7 PANEL 1i PANEL RPPO7B01 PPPO7B071 42 I 42 POLE 1 POLE •-'80% ,.'80% 1 1 _J_ PANEL 1, PANEL IRPP07C04ItPP07C04 42 42 POLE POLE J �►--1--•� 1 ti►--� 1 .11'13P '11'13P 1 16'13P'= 4"13P 1 f'80% 1180% "I 80% g180% 1 1 1 1 1 1 it-J--1 r-J--7 I r--1--7 r--1---1 i PANEL 1, PANEL I li PANEL ,1 PANEL 1 RPPO8A01I pPPO8A071 I IRPPO8DOOPP08D04I i 42 42 1 42 42 POLE POLE 1 POLE POLE 1 1 1 L---_JL---_J JL____J1_---_J 1 J 0.F.C.I. r 0.F.C.I. PDU 'PDUB1000' 500kVA, 480V, 30, 3W INPUT 208Y/120V, 30, 4W OUTPUT 98.36% EFF. 1 2 3 CD 4 •1 800A j 3P 5 6 7 600AF •) 450AT •) 450AT •) 450AT •) 450AT •/ 450AT +) 450AT •/ 450AT •) 450AT 3P 3P 3P 3P 3P 3P 3P 3P (026 )( 027 )( 028 )( 029 )C 043)( 043 ) <`A3, FUT. <B3;> \Y RPP \Y I'RPP03000' I i 1 i r 225A 1 2251 225A - 1225A 4' 3P 4' 3P 4s 3P 4' 3P M 80% y-'80% Ir.'80% •'80% r--1--1 r-J--- r--1--1 r--1---1 11 1 1 11' 1 PANEL 1, PANEL i 1 PANEL 11 PANEL RPPO3A01112PPO3A041 pPP03130412PP031301 42 I 42 1 42 1 42 POLE 1 POLE i. POLE i POLE 1 1 1 1 I 1 LL_ _J L_ JJL_ JL _J <A5> FUT. <;B5;> Y RPP \Y I'RPP09000' I J 1 - ' 1 1 - 1 I I 225A 1 225AI I 225A 1 225A, 1 k13P !l''13P '''13P k13P Y I '80% •.'80% I y- 80% T'80% 1 I 1 1 1 1 --1-- ;; -J--1 I i -J-- i i -J--7 iI PANEL 11 PANEL i lI PANEL 11 PANEL I IRPPO9A011 pPPO9A071 ' PPO9C04 PPPO9C041 11 42 42 I I 42 I 42 POLE 1, POLE i POLE 1 11 1 1 I IL____JL____J L__--JL___-J IL____J1-----J L----JL___ J J JL J 0.F.C.I. u u u I I ( FUT. )( FUT. )(. FUT. 1( FUT. ) /\ / --T- -_T_-/-_T.-- _T_- / l\ / l\ / •\ A\ <B3; <B4;> <B5;> <B6;> RPP 'RPP04000' 0.F.C.I. RPP 'RPP05000' r22-5/1 2251 225A 225A r80% ro% % )80% PANEL RPPO4A01 42. POLE PANEL 2PPO4AO2 42 POLE PANEL PPO4D0; 42 POLE PANEL 2PPO4D04 42 POLE 225A 225P� 1)80% * 80% PANEL RPPO5B0' 42 POLE PANEL 2PP05B0o 42 POLE PANEL 2PPO5C0: 42 POLE PANEL 2PPO5C04 42 POLE <C5;> FUT. <D5;> Y RPP \Y I'RPP10000' I r1 ,..----L--.1 I r 225A-i' 2251 I225A II225A, I k 3P . £'13P 4') 3P A13P i T'80% 1'80% Y'80% *'80% Ir-J--7r-J--7 r-J--1r-J--7 1 ii PANEL I PANEL i 1 PANEL 111 PANEL 11 :IRPP108011iPP10B04 liPP10D04 IRPP1ODO4I i I 42 I 42 I 42 42 POLE i POLE POLE I 1 I I 1 r 1 1 I ii ii PANEL II PANEL :pPP1160112PP11 B071 I 42 42 POLE POLE <;B6,> FUT. <,C6,, \Y RPP Y I'RPP11000' I 225A 1' 1 2251 'Ili 225A -1 225A, "'13P •113P `'''13P J'`13P y'8O% *'80% Ir-'80% r'80% r-J--7r-J--7 PANEL 1, PANEL )PP11C04 pPP11C04I I 42 42 POLE POLE 0.F.C.I. L 1 0.F.C.I. 800A +) 3P t PDU 'PDUC1000' 500kVA, 480V, 30, 3W INPUT 208Y/120V, 30, 4W OUTPUT 98.36% EFF. 1 2 KK KK 800A 3P Il I I ' 1)600AF II•/ 450AT •) 450AT •) 450AT +l 450AT •/ 450AT •450AT •/ 450AT •) 450AT 3P 3P 3P 3P 3P 3P 3P 3P ( 030 )( 031 )( 032 )( 033 )( 044 )C 044 ) 41:4 c3\, FUT. <'D3�> Y RPP 3, I'RPP06000' I r i1 i 225A - 1 2251 1 225A 1 225A 4'13P !‘13P 1 '11'13P T'80% *'80%I_ 7'80% 1'80% r-J---1 r--1--1 I r-J--7 r-J7 PANEL 1, PANEL i , i PANEL 1, PANEL RPPO6C01 PPO6C0� 1�tPPO6D04 IRPP06D01 42 42 I 42 42 POLE POLE 1 POLE POLE 1 L J L J <A6 > FUT. <'D6\> ''T/ RPP `\Y I'RPP12000' I 4'‘ 3P W13P I 111:80% 4,180% 1 1 I ii i 1 ii PANEL 11 PANEL I IRPP12A01I PPP12A071 11 42 a 42 ii POLE ,, POLE 11 11 11 11 11 11 11 I1 IL____JL____JJL____JL____J J L r 1 • 1 1 PANEL 1, PANEL 42 42 POLE POLE 0.F.C.I. PDU 'PDUD1000, 500kVA, 480V, 30, 3W INPUT 208Y/120V, 30, 4W OUTPUT 98.36% EFF. 3P r 2 KK KK ) 800A 7 8 3P 3P 3P 3P 3P 3P 3P 3P Plan review approval is ailed to eras and missions. thE. violation of any adopted code or orthnmce, Receipt itporoval of constrtetion dot:units does not authorize remit NF0I. isoadoxlmedgediji sor: of approved Field BY City Of Tkikwila BUILDING DIVISION ELECTRICAL ONE -LINE DIAGRAM SCALE: NOT TO SCALE ONELINE DIAGRAM GENERAL NOTES 1. REFER TO GENERAL ELECTRICAL NOTES, SYMBOLS, AND ABBREVIATIONS SHEET E0.1 FOR ALL SYMBOLS ON THIS SHEET. 2. REFER TO SHEETS E0.2 AND E0.3 FOR ELECTRICAL SPECIFICATIONS. 3. GROUND UPS EQUIPMENT AS RECOMMENDED BY MANUFACTURER, AS SHOWN ON SHEET E1.2 AND REQUIRED PER N.E.C. 4. PROVIDE CONTROL WIRING BETWEEN UPS AND MAINTENANCE BYPASS CABINET PER MANUFACTURER'S RECOMMENDATIONS. 5. PROVIDE CONTROL WIRING BETWEEN UPS AND BATTERY CABINETS PER MANUFACTURER'S RECOMMENDATIONS. 6. REFER TO SHEET E4.1 AND E4.2 FOR FEEDER SCHEDULES, LOAD ANALYSIS, AND FAULT CURRENT DUTY SCHEDULE. 7. PHASE ROTATION SHALL BE A-B-C CLOCKWISE THROUGHOUT SYSTEM. 8. REFER TO SHEET E3.6 FOR GENERATOR CONTROL SYSTEM WIRING. ONELINE DIAGRAM KEYED NOTES 0 GENERATOR NEUTRAL BONDING TO BE ACCOMPLISHED AT SWITCHBOARDS ''GSB-1" AND ”GSB-2". DISCONNECT NEUTRAL -GROUND BOND AT GENERATOR. 0 REFER TO DRAWING 1 /E3.5 FOR CONTROL WIRING AT GENERATOR, ATS, GSB-1, GSB-2. 0 PROVIDE FULL SIZED FEEDER FROM JUNCTION BOX TO GENERATOR SWITCHBOARD. PROVIDE COMPRESSION TAPS. TYPICAL FOR ALL GENERATOR FEEDERS. NEUTRAL/GROUND BOND BY MANUFACTURER. 0 PROVIDE 500MCM NEUTRAL/GROUND BOND. 0 REFER TO GROUNDING ONE LINE DIAGRAM SHEET E1.2. 0 UNIT MOUNTED DISCONNECT PROVIDED WITH EQUIPMENT (TYPICAL FOR ALL CRAC'S AND ACCU'S UNLESS OTHERWISE NOTED). 0 30A/3P/15AF/N1 DISCONNECT PROVIDED AND INSTALLED BY E.C. 0 30A/3P/15AF/N3R DISCONNECT PROVIDED AND INSTALLED BY E.C. CD1 NEW UTILITY TRANSFORMER BY UTIMY COMPANY. CONTRACTOR TO PROVIDE TRANSFORMER PAD AND COORDINATE ALL REQUIREMENTS WITH THE UTILITY COMPANY. 0 NEW UTILITY UNDERGROUND PRIMARY FEEDER. PROVIDE (2) 6n PVC CONDUITS WITH CONCRETE ENCASEMENT AND PULLSTRINGS FROM NEW UTILITY SWITCH. COORDINATE ALL REQUIREMENTS WITH UTILITY COMPANY. 0 NEW UTILITY SERVICE LATERAL 0 PROVIDE PULLBOX SIZED TO PROVIDE TERMINATIONS FOR REMOVAL OF FEEDER FROM PRESENT SOURCE AND EXTENSION TO FUTURE MDS SWITCHBOARD UPON INSTALLATION OF FUTURE SWITCHBOARD. 0 ADJUST LTPU SETTING OF BREAKER TO 3600 AMPS. MECHANICAL DIST. PANEL 'MDPA1000' 800A, 480V, 30, 3W, 65KAIC 1 5 6 I) 3110A IN 3_02A IN 15A )3P 10 11 12 13 14 • SPARE SPARE PREP. PREP. SPACE SPACE (71-3) Ortu CRA 03000 (DATA CENTER) , B8 041 ERP- 03000 (DATA CENTER) Ce; OE CON- 05031 (DATA CENTER) CON 06032 (DATA CENTER) FUT. CRA- 05000 (DATA CENTER) • 1-1 FUT. ERP- 05000 (DATA CENTER) FUT. CON- 09051 (DATA CENTER) FUT. CON- 10052 (DATA CENTER) FUT. CRA- 09000 (DATA CENTER) FUT. ERP- 09000 (DATA FUT. CON- 17091 (DATA CENTER) FUT. CON- 18092 (DATA CRA 09000 (ISS) CON 26151 MECHANICAL DIST. PANEL 'MDPB1000' 800A, 480V, 30, 3W, 65KAIC 1 2 3 4 5 FUT. CRA- 15000 (ELEC ROOM) 20A Fi FUT. CON- 27151 (ELEC ROOM) ) 3P CRA- 02000 (DATA CENTER) • ERP- 02000 (DATA CENTER) 6 7 8 Id 3P oi -Om CON- 03021 (DATA CENTER) CON- 04022 (DATA CENTER) FUT. CRA- 06000 (DATA CENTER) FUT. ERP- 06000 (DATA CENTER) SPARE .)S3PPARE .1) P • FUT. FUT. CON- CON- 11061 12062 (DATA (DATA CENTER) CENTER) FUT. CRA- 10000 (DATA CENTER) 12 13 14 FUT. ERP- 10000 (DATA CENTER) 3P • 3P • PREP. PREP. SPACE SPACE FUT. CON- 19101 (DATA CENTER) FUT. CON- 20102 (DATA CENTER) MECHANICAL DIST. PANEL 'MDPC1000' 800A, 480V, 30, 3W, 65KAIC 1 2 4 20A I\ 110A I\ 30A L 110A IN 30A L 110A L 30A 12 13 14 SPARE SPARE 125A 3P PREP. SPACE 480V:208Y/120V 75kVA, NEMA 1 97.7% EFF - 053 NEW PANEL CRA- 07000 (ELEC ROOM) CON- 13071 (ELEC ROOM) CRA- 01000 (DATA CENTER) ERP- 01000 (DATA CENTER) CON- 01011 (DATA CENTER) '0,„ CON- 02012 (DATA CENTER) FUT. CRA- 07000 (DATA CENTER) FUT. ERP- 07000 (DATA CENTER) FUT. CON- 13071 (DATA CENTER) FUT. CON- 14072 (DATA 1.1 FUT. CRA- 11000 (DATA CENTER) REVIEWED FOR COMPLIANCE WITH City o -Tukwila - , BUILDING DIVISION • FUT. ERP- 11000 (DATA FUT. CON- 21111 (DATA CENTER) 75kVA, NEMA 1 97.7% EFF MECHANICAL DIST. PANEL MDPD1000' 800A, 480V, 30, 3W, 65KAIC L 1_2_5A I j 530pA CRA- 08000 (ELEC ROOM) CON- 14081 (ELEC ROOM) FUT. CRA- 04000 (DATA CENTER) FUT. ERP- 04000 (DATA CENTER) 131p0A 330pA L 1 1 OA FUT. CON- 07041 (DATA CENTER) FJ FUT. CON- 08042 (DATA CENTER) qf FUT. CRA- 08000 (DATA CENTER) FUT. ERP- 08000 (DATA CENTER) • FUT. CON- 15081 (DATA CENTER) 11 FUT. CON- 16082 (DATA CENTER) I 110A L 30A I 125A FUT. CRA- 12000 (DATA CENTER) FUT. CON- 22112 (DATA CENTER) RECEIVED CITY OF TUKWILA PERMIT CENTER REVISION NOI_L st.14-01145 FUT. ERP- 12000 (DATA CENTER) FUT. CON- 23121 (DATA CENTER) FUT. CON- 24122 (DATA CENTER) Gensler Two Lincoln Centre Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 CD CD cn 0 0 oo co (42 1 ISSUES & REVISIONS No. Date Description 1 02/17/2014 ISSUE FOR PERMIT A03/28/2014 ADDENDUM 1 SHEET ITTLE ELECTRICAL ONELLNE DIAGRAM DRAWN: WAM REVIEWED: RWB PROJECT NO.: C1047.00 420 PROPRIETARY: NOT FOR D SCLOSURE OR US THO THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. N-G LINK WHERE - REQUIRED BY EQUIPMENT MANUFACTURER N-G LINK WHERE P N I o 0 0 0 0 0 0•••••••••• •— •• •— .:. . •.• •_ 0 0 0 0••• •— •• •— 0 0 0• 0•• •— 0 0 0 0 0 0• •• 0 0 0 0 0 0 0 0 0 0 0 IY,Y _YY 777 7Y g co 1(col (0 0 o 1181 0 0 ��CD CD �0�0wC�)Y I 8 II0 0 0 oj 10 0 0 -T- U U 0 0 0 'UPSA1000' 1 NEUTRAL BUS GROUND BUS 'UPSB1000' REQUIRED BY � NEUTRAL BUS EQUIPMENT MANUFACTURER N-G LINK WHERE --N REQUIRED BY EQUIPMENT MANUFACTURER N-G LINK WHERE -N REQUIRED BY EQUIPMENT MANUFACTURER GROUND BUS FUT 'E 'UPSC1000' NEUTRAL BUS I -4--- 1 LGROUND BUS J FUTURE 'UPSD1000' Nr I 1 NEUTRAL BUS I I r LGROUND BUS I GROUNDING CONDUCTOR SCHEDULE MARK CONDUCTOR SIZE CONDUIT SIZE REMARKS G001 500kCM 1-1/2" BARE TINNED, PROVIDE SCHEDULE 80 PVC AT EXTERIOR OF BUILDING G002 500kCM NONE BARE TINNED G003 500kCM 1-1/2" INSULATED G004 #1/0 1" INSULATED G005 #6 3/4" INSULATED G006 #2 3/4" INSULATED G007 #4 NONE BARE TINNED G008 #4/0 1" INSULATED G009 #4/0 NONE INSULATED G010 #2/0 NONE INSULATED G011 #4 NONE INSULATED G012 #2/0 NONE BARE TINNED G013 #2 NONE INSULATED G014 #2/0 1" INSULATED NOTE: ALL CONDUCTORS ARE STRANDED COPPER WITH GREEN INSULATION UNLESS NOTED OTHERWISE. ALL CONDUCTORS LOCATED BENEATH THE RAISED FLOOR SHALL BE MARKED "FOR USE IN CABLE TRAYS" OR "FOR CT USE" PER NEC ART. 645.5(E)(6)b. PROVIDE SCHEDULE 40 PVC CONDUIT INTERIOR TO THE BUILDING AND SCHEDULE 80 EXTERIOR TO THE BUILDING. GROUNDING GENERAL NOTES 1. ALL BARS, LUGS, AND CONDUCTORS PROVIDED BY ELECTRICAL CONTRACTOR UNLESS NOTED OTHERWISE. 2. CONTRACTOR SHALL USE CADMIUM YELLOW, ZINC CHROMATE, OR STAINLESS STEEL BOLTS FOR CONNECTIONS TO GROUND BARS. 3. BEND RADIUS FOR GROUNDING CONDUCTORS SHALL BE AT LEAST 12 INCHES THRU #4/0 AND AT LEAST 24 INCHES FOR GROUNDING CONDUCTORS GREATER THAN #4/0. 4. PULL BOXES IN DEDICATED GROUNDING SYSTEM AS SHOWN ON THIS SHEET SHALL BE KEPT TO A MINIMUM AND SHALL BE NON-METALLIC OR ELECTRICALLY ISOLATED FROM ADJACENT CIRCUITS AND BUILDING COMPONENTS. 5. GROUND BAR CONDUCTORS SHALL NOT SHARE CONDUITS OR PULL BOXES WITH CONDUCTORS OR CABLES OF OTHER SYSTEMS. 6. ALL BARE GROUNDING CONDUCTORS SHALL BE TINNED. 7. STRANDED GROUNDING CONDUCTORS SHALL HAVE CLASS B STRANDING. 8. GROUNDING SYSTEM IMPEDENCE SHALL NOTEXCEED5 OHM. CONTRACTOR SHALL ADD CHEMICAL GROUND ROD(S) AS NECESSARY TO ADHERE TO THIS REQUIREMENT. 9. ALL GROUNDING SHALL COMPLY WITH NEC ARTICLE 250 AS A MINIMUM UNLESS NOTED OTHERWISE. 10. ALL GROUNDS SHALL BE COPPER, NO ALUMINUM SHALL BE PERMITTED. 11. ANY REQUIRED CONDUIT FOR GROUNDING SHALL BE PVC UNLESS NOTED OTHERWISE. NO METAL CHOKES SHALL BE ACCEPTABLE. SUPPORTS FOR GROUNDING CONDUITS SHALL UTILIZE NYLON BOLTS AND NON-METALLIC STRAPS TO PREVENT INSTALLATION OF CHOKE POINT IN GROUNDING SYSTEM. 12. ALL COMPRESSION LUGS SHALL BE TWO -HOLE LONG BARREL AND CRIMPED USING THE MANUFACTURER'S RECOMMENDED DIE AND CRIMPING TOOL. GROUND LUGS SHALL BE SHRINK-WRAPPED AND LABELED WITH NONMETALLIC TAGS. 13. TOTAL GROUNDING CONDUCTOR BENDING RADIUS SHALL NOT EXCEED 90' AT EACH LOCATION. 14. GROUNDING CONDUCTORS SHALL BE CONTINUOUS BY GAUGE FOR ENTIRE LENGTH. SPLICES ARE NOT ALLOWED. 15. LEXAN COVER FOR ALL GROUND BARS SHALL BE LABELED WITH GROUND BAR NAME AND PANI DIVISIONS. 16. CONNECTIONS TO ALL BUS BARS SHALL BE IN PANI LOCATIONS AS INDICATED ON THIS SHEET. 17. PANI DESIGNATION LOCATIONS SHOWN ON THIS SHEET ARE SCHEMATIC IN NATURE. PROVIDE ADEQUATE MOUNTING HOLES AT EACH DESIGNATION LEI IER FOR PRESENT AND FUTURE CONNECTIONS. 'TRNC1000' (75kVA) 'TRND1000' (75kVA) 'PDUA1000' (500kVA 'PDUB1000' (500kVA) 'PDUC1000' (500kVA 'PDUD1000' (500kVA EXOTHERMIC WELD TO NEW REBAR LOCATED IN NEW CONCRETE SLAB AT EQUIPMENT YARD PER NEC GENERATOR 'GEN01000' GENERATOR 'GEN02000' FUTURE GENERATOR 'GEN03000' r -i -�\ 1'- t-N. G002 }-�+� _ _/ / 1 -.lc- (G002)--0 EXOTHERMIC WELD TO NEW REBAR LOCATED IN NEW CONCRETE SLAB AT EQUIPMENT YARD PER NEC FUTURE GENERATOR 'GEN04000' r I-* C r� FUTURE GENERATOR 'GEN05000' r -� 1 /- I k-�\ / / N _� t C FUTURE GENERATOR r 'GEN06000' EXOTHERMIC WELD TO NEW REBAR. LOCATED IN NEW CONCRETE SLAB AT EQUIPMENT YARD PER NEC EXOTHERMIC WELD TO NEW REBAR LOCATED IN NEW CONCRETE SLAB AT EQUIPMENT YARD PER NEC - --( G002 }-rJ EXOTHERMIC WELD TO NEW REBAR LOCATED IN NEW CONCRETE SLAB T U ' ENT YARD PER NEC - - G002 )— ' - EXOTHERMIC WELD TO NEW REBAR LOCATED IN NEW CONCRETE SLAB AT EQUIPMENT YARD PER NEC - -G002)-rJ EXOTHERMIC WELD TO NEW REBAR LOCATED IN NEW CONCRETE SLAB AT EQUIPMENT YARD PER NEC NOTE: BOND EACH GENERATOR FUEL TANK TO REBAR IN CONCRETE SLAB UTILIZING "G002" CONDUCTOR. REFER TO GROUNDING PLAN FOR GROUND ROD AND TEST WELL LOCATIONS AND QUANTITIES N-G LINK G002 ABOVE GRADE BELOW GRADE UTILTY METERING CABINET NEUTRAL BUS L GROUND BUS N-G LINK N-G LINK J 'GSB01000' NEUTRAL BUS r 1- GROUND BUS 'GSB02000' 1 NEUTRAL BUS i GROUND BUS VERIFY WITH OWNER - QUANTITY OF RACKS TO BE INSTALLED IN EACH ROW. (TYPICAL) 10'-0" (TYP.) ROW 2 ROW 3 ROW 4 ro 0 0 0 0 0 ABOVE GRADE BELOW GRADE WATER SERVICE ENTRANCE PIPING -(co)--G2HH---(G002)J N) 0 0 'MSG01000' MOUNTING: 8'-0" ABOVE FINISHED FLOOR LOCATION: ELECTRICAL ROOM 'PGP01000' MOUNTING: HORIZONTAL AT 8'-0" ABOVE RAISED FLOOR LOCATION: DATA CENTER A N I 0 0 0 0• 0• 0 0 0••••• 0 p• p• •• •• 0 0 0 0 0 CABLE TRAY ABOVE RAISED FLOOR 0 0- o o U�U�U 03 co o 0 0 0 U U ABOVE RAISED FLOOR � n 0) rn 0 0 0 0 0 0 rnrn� 0 0 0 0 CD 0 U U 'EFG01000' MOUNTING: HORIZONTAL BELOW RAISED FLOOR LOCATION: DATA CENTER N II 0 0 0 0• 0 0 • • • • • • • • 0 0 0 0 0 0 O O 0 00 0 0•••••••• 0 0 0 0 0 0 0 7 I EQUIP I RACK 1 L (GO11) T 1 EQUIPRACK 1 . 1 LI -i- J (GO11) TJ `a S � 10 0 0 o o off.6 0 0 EQUIP. RACK GO11 EQUIP. RACK T GO11 EQUIP. 1 RACK 1 L -1- J ( G011 ) T f ---I EQUIP. RACK L ( GO 1 ) T 1 EQUIPRACK. 1 1 1 L (GO11) BELOW RAISED FLOOR P 'EFG02000' MOUNTING: HORIZONTAL BELOW RAISED FLOOR LOCATION: MMR1 A N I 0 0• 0 0 0 0 0 0 0• 0 0 0 0 0 0 0 /7 TYPICAL EQUIPMENT RACK ON COMPUTER ROOM RAISED FLOOR. EQUIP. 1 RACK L GO 1 ) T ROW 5 OUTE UNDER FLOOR DOWN RACK ROW TYPICAL FOR EACH ROW — 1 EQUIP. 1 1 LEQUIP. 1 1 RACK 1 I RACK I ROW 6 (GO11) (GO11) -r T� ? -01 I----1 I ----I EQUIP. EQUIP I RACK L-1-J (GO11) `T_, EQUIP. 1 RACK L_i-J (GO11) `T__. GROUNDING ONE -LINE DIAGRAM NOT TO SCALE 1 L RACK ROW 7 —1—J GO11 ) 1----! EQUIP. RACK L (GO11) T� i 1 ROW 8 P 'RFG01000' P 'EFG03000' MOUNTING: HORIZONTAL BELOW RAISED FLOOR LOCATION: MMR2 A N I 0 0• 0 0 0 0 0 0 o• 0 0 0 0 0 0 0 MOUNTING: HORIZONTAL BELOW W RAISED FLOOR LOCATION: DATA CENTER A N I 0 0• 0• 0 0 0•• 0•• — — 0 0 0 O 0 — 77 COMPUTER ROOM RAISED FLOOR GROUND GRID UL LISTED 'C' OR 'H' TAP COMPRESSION FITTING (TYP. WHERE SHOWN ON THIS SHEET). E3 -(G013 RPP EQUIPMENT TYP. REVIEWED FOR COMPLIANCE WITH NPPA70-NEC APR 17 2014 C o Tukwila BUILDING, DIVISION RECEIVED CITY OF TUKWILA APR 1 1 2014 PERMIT CENTER 10400 Rodgers Road HOUSTON, TEXAS 77070 Ph: 281-374-8644 Fax: 281-374-8992 Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 CID C-1 C:`,) CD t::71) co co co � Q rn Q C") J ir ISSUES &REVISIONS No. Date Description 1 02/17/2014 ISSUE FOR PERMIT © 03/28/2014 ADDENDUM 1 C SHEET TITLE GROUNDING ONE -LINE DIAGRAM DRAWN: WAM REVIEWED: RWB PROJECT NO.: C1047.00 SHEET NO. E1.2 PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. UPS81000 BATT. BATT. BAIT.0 BATE. BATT. BAIT. UPSA1000 ELECTRICAL SITE PLAN SCALE. 1/16•-1-0• SITE PLAN GENERAL NOTES 1. REFER TO SHEET E0.1 FOR ALL SYMBOLS ON THIS SHEET. 2. REFER TO SHEET E0.2 AND E0.3 FOR ELECTRICAL SPECIFICATIONS. 3. REFER TO SHEET E1.1 FOR ELECTRICAL ONE LINE DIAGRAM. 4. REFER TO SHEET E4.0 FOR FEEDER SCHEDULE. SITE PLAN KEYED NOTES 0 0 0 0 0 0 0 0 NEW UTILITY PAD MOUNTED TRANSFORMER. PROVIDE PAD, REQUIRED GROUNDING, SOIL WORK, ETC. AS REQUIRED BY THE UTILITY COMPANY. COORDINATE ALL REQUIREMENTS WITH THE UTILITY COMPANY. NEW UNDERGROUND FEEDER FROM TRANSFORMER SECONDARY TO NEW METERING EQUIPMENT. REFER TO DETAIL 6/E3.3. NEW 4000A UTILITY METERING CABINET. INSTALL PER UTILITY COMPANY REQUIREMENTS. NEW UNDERGROUND SERVICE LATERAL REFER TO DETAIL 5/E3.3. NEW UNDERGROUND PRIMARY. PROVIDE (2) 6" CONDUITS WITH PULLSTRINGS PER UTILITY COMPANY REQUIREMENTS. WHERE CONDUITS ARE INSTALLED IN TRENCHES AND NOT BORED PROVIDE RED CONCRETE ENCASEMENT. PROVIDE SPARE (2) 1" CONDUITS STUBBED OUT FROM BREAKER COMPARTMENT TO INTERIOR OF ELECTRICAL ROOM. EXISTING UTILITY COMPANY METERING ROOM. REFER TO SHEETS E2.D, E2.1, E2.2, E2.3 AND E2.4 FOR WORK IN THIS AREA. REVIEWED .FOR COMPLIANCE WITH NFPA7O-NEC APR 17 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 1 1 20i4 PERMIT CENTER Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 X CD 0 173. D: EDCSEA01 LLJ CJ) ISSUES & REVISIONS No. Date Description 1 02/17/2014 ISSUE FOR PERMIT A03/28/2014 ADDENDUM 1 1 SHEErriThE ELECTRICAL SITE PLAN SHEET NO. DRAWN: WAM REVIEWED: RWB PROJECT NO.: C1047.00 E2.0 PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. 1 (13) /J 1 / LOADING 14 DOCK �J �-LTTyJ4 630 SF LCPC1000-9 LCPC1000-11 LCPC1000-34,36 2#6, #10G., 3/4"C. 60/2/NF/N1 \7 FCU03000 (14) RE -AC TUN L116J FD_2 89 SF LCPD LCPD1000 COLD AISLE I--1--1--1 H OT AISLE COLDD AISLE COLD AISLE HOT . LE 60/2/N GEN01000 (600K`w) e v LCPC1000-31,33 MBCC1000 5 LCPD1000-35 LC'C1000-19 (16 e"� CON15091 3 MDP (FUTURE) O r LJ LCPD1000-14 '.� RtitRW iiAuiih"!!'i i4u!:i wit is p is ,Lim. • 1 r-, CRA15000 -' UPSC1000 I BATT 1 BATT- I BATT. I i LCPD 1 ' ILCPC 1000 IRNU IRNt, 1000 1000 1000 LCPC1000-15 -i----r---- -----1 1 UPSD1000 I BATT. I BATT. I BATT. 1 _1.----1-----I ---_J 000-15 14 STAGE L117 283 SF DATA CENTER PHASE II ELECTRICAL RM MDPi1000 3 MDPc1000 2 MDPB1000-4 MDPB1000-3 O 118 J 2004 SF 17) Mt- •akil i 414L WIR 'r' i-1 iE M:h-r: M Mi.:. i t la: FRONT FRONT 1.� IR.p'wi( MI u;i Ili i.� 01000 MDPC1000-2 FRONT FRONT rRON1 FRONT n f-------I MDSC bIDSB UPSB1000 BATT. BATT. BATT. MDPCI ! IATSC I I 10001 111000 L1000 J ATSE 100E 1000 I I- [1 Hi - -a BATT. BATT, BATT. UFSA1000MDSD MDPD1 1--� ATSD I : 10001J 11000 I1000 I MDSA 1000 ATSA 1000 ! .-�....T �� .,t L--�-J MDPD1000- CRA080I0-i" if, au i, ilh-: izo:" ; MEN H-0 102 98 SF MMR2 L 101 J 234 SF 15 FRONT 0 EPO STA. #1 FRONT •11- PDUA10 1000-1\i 1000-1 \ PDUD10 PDUD1 PDUC1 (16 FRONT AVMiIrg. t4k it gym 100. 100. 7 8 DATA HALL 1 L 100 J 3756 SF LCPD1 ELECTRICAL POWER PLAN SCALE' 1/8•-1'-0• 1000-'7 100-29 11 EPO A. #2 CRA07000 MDPB 100E tePD100i- MMR1 L 109 J 194 SF (18) EXF02000 (ON ROOF) LCPC100 LCPC 2#6, 3/4" LCPC1 000-24,26 # 10G., 60/2/NF/N1 LANDIN 106 FCU2000 429 SF 1000-24,26 18 RR 112 58 SF LCPC1000-1 LCPC1000-7 ®I G}I AC CPC1000-5 60 2 NF N1 LOBBY [ 110.1 J 258 SF RPPO4A01-1,2,3 � IAGE FCU1 000 LCPD1000-7 12 LCPD1000-9 12 POWER PLAN GENERAL NOTES 1. REFER TO SHEET E0.1 FOR ALL SYMBOLS ON THIS SHEET. 2. REFER TO SHEETS E0.2 AND E0.3 FOR ELECTRICAL SPECIFICATIONS. 3. SEE ONE LINE DIAGRAMS AND FEEDER SCHEDULES FOR FEEDER SIZES AND EQUIPMENT SIZES NOT INDICATED ON THIS PLAN. 4. INSTALLATION OF ALL UNDERFLOOR UL LISTED POWER WHIPS IN THE RAISED FLOOR AREAS SHALL INCLUDE THE WHIP AND ITS ASSOCIATED CIRCUIT BREAKER IN THE INDICATED RPP PANEL 5. SEE MECHANICAL PLANS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OF HVAC EQUIPMENT. 6. ALL SINGLE PHASE BRANCH CIRCUITS ARE (3) #12, 3/4" C UNLESS IDENTIFIED OTHERWISE ON THIS PLAN, ELECTRICAL ONE LINE DIAGRAMS, OR AS REQUIRED BY SHEET E0.1 TO BE INCREASED DUE TO VOLTAGE DROP PER N.E.C. NEUTRAL CONDUCTORS SHALL NOT BE SHARED. 7. REFER TO 1/E3.2 FOR MOUNTING HEIGHT OF DEVICES. 8. POWER REQUIREMENTS TO RACK MOUNTED COMPUTER HARDWARE EQUIPMENT ARE UNDEFINED AT THIS TIME. WHEN OWNER SELECTS EQUIPMENT, ENGINEER SHALL SUBMIT BRANCH CIRCUIT DISTRIBUTION REQUIREMENTS TO CONTRACTOR FOR INSTALLATION. POWER WILL BE DISTRIBUTED VIA LIQUIDTIGHT CONDUIT (UL LISTED POWER WHIPS) UNDER RAISED FLOOR FROM REMOTE POWER PANELS (RPP) SHOWN IN DATA CENTER. ENGINEER WILL CONFIRM LOAD DOES NOT EXCEED THE CAPACITY OF THE RPP'S AND UPSTREAM ELECTRICAL DISTRIBUTION. 9. REFER TO SHEET E2.0 FOR ADDITIONAL CONDUIT ROUTING REQUIREMENTS. 10. WARNING SIGNS AND NFPA 704 HAZARD IDENTIFICATION SIGNS SHALL BE INSTALLED TO CLEARLY IDENTIFY HAZARDS PER LSB STANDARD 13 SECTION 5.7. SIGNS SHALL HAVE RED COLORED LETTERING ON A WHITE BACKGROUND, STATING: 'NO SMOKING, WELDING, OR OPEN FLAMES WITHIN 25 FEET' SIGNS SHALL BE PROVIDED ON THE SIDES OF TANKS OR SECURITY FENCING IN THE DIRECTION OF FIRE DEPARTMENT APPROACH. WARNING SIGNS AND NFPA 704 HAZARD SIGNS SHALL HAVE LETTERING AT LEAST 3 INCHES IN HEIGHT OF WEATHER -RESISTIVE MATERIALS. 11. PROVIDE 3.5" CONCRETE HOUSEKEEPING PADS FOR INTERIOR EQUIPMENT AS SHOWN. PAD SHALL BE MINIMUM OF 3" LARGER THAN EQUIPMENT ON ALL SIDES. 12. PROVIDE CANBUS CONDUIT AND CABLING BETWEEN CRA/ERP/CON PER DETAIL 3/E3.5. POWER PLAN KEYED NOTES O O O 0 O O O 10 11 12 13 14 15 17 18 PROVIDE CONNECTION TO GENERATOR WATER JACKET HEATER. (2) #6, #8 G. IN 1-1/4" CONDUIT ROUTED WITH GENERATOR FEEDER. CIRCUIT OVER -SIZED FOR MORE THAN THREE CURRENT CARRYING CONDUCTORS IN ONE CONDUIT. PROVIDE CONNECTION TO GENERATOR BATTERY CHARGER. (2) #10, #10 G. IN 1-1/4" CONDUIT ROUTED WITH GENERATOR FEEDER. CIRCUIT OVER -SIZED FOR MORE THAN THREE CURRENT CARRYING CONDUCTORS IN ONE CONDUIT. PROVIDE CONNECTION TO CONDENSING, FIELD VERIFY EXACT TERMINATION LOCATION. REFER TO E1.1 FOR CIRCUITING REQUIREMENTS AND E1.4 FOR UNDERGROUND CONDUIT ROUTING. PROVIDE CONNECTION TO REFRIGERANT PUMP, FIELD VERIFY EXACT TERMINATION LOCATION. REFER TO E1.1 FOR CIRCUITING REQUIREMENTS. PROVIDE CONNECTION TO CRAC, FIELD VERIFY EXACT TERMINATION LOCATION. REFER TO E1.1 FOR CIRCUITING REQUIREMENTS. UNIT HAS INTEGRAL MOUNTED DISCONNECT SWITCH INCLUDED AS OPTION WITH UNIT. PROVIDE INDUSTRIAL GRADE RETRACTABLE POWER CORD REEL, KH INDUSTRIES REELTUFF POWER CORD REEL MODEL NUMBER RTBB3L-WW-J12K. 50 FOOT 12/3 SJ CORD, 125V, 20A WITH SINGLE 5-20R RECEPTACLE. PROVIDE OPTIONAL 345 DEGREE PIVOT BASE, MODEL NUMBER RTBF-PVB. MOUNT REEL AT CEILING HEIGHT, SUPPORTED FROM STRUCTURE ABOVE. PROVIDE ADDITIONAL SAFETY CHAIN FROM STRUCTURE ABOVE TO REEL BASE. ONCE INSTALLED THERE SHALL BE NO NOTICEABLE MOVEMENT IN EITHER THE VERTICLE OR HORIZONTAL DIRECTIONS. FIELD VERIFY EXACT LOCATION WITH BCEI PRIOR TO INSTALLATION. PROVIDE CONNECTION TO RPP. FIELD VERIFY EXACT TERMINATION LOCATION. REFER TO ONE LINE DIAGRAM FOR CIRCUITING REQUIREMENTS. PROVIDE INTERFACE TO LOCKOUT REHEAT/HUMIDIFICATION DURING TRANSFER TO GENERATOR POWER. REFER TO DETAIL 1/E3.5. PROVIDE CONNECTION TO WATER HEATER. EPO SYSTEM PANEL PROVIDED BY FA CONTRACTOR, INSTALLED BY E.C. REFER TO DETAIL 1/E3.4 FOR ADDITIONAL INFORMATION. EPO BREAKGLASS BUTTON. COORDINATE EXACT LOCATION WITH ADJACENT DEVICES NOT SHOWN ON THIS PLAN. REFER TO DETAIL 1/E3.4 FOR ADDITIONAL INFORMATION. POWER CONNECTION TO EQUIPMENT. SEE 2/E3.5 FOR POWER REQUIREMENTS. FIELD VERIFY EXACT LOCATION WITH BCEI PRIOR TO ROUGH -IN. 4'X8'X5/8" FIRE RATED PLYWOOD MOUNTED ON WALL FOR PHONE BOARD. FIELD VERIFY EXACT LOCATION OF QUAD ON PHONE BOARD WITH BCEI PRIOR TO INSTALL PULLBOX FOR OUTSIDE FIBER, PROVIDED AND INSTALLED BY OTHERS. FAN CONTROLLED BY OCCUPANCY SENSOR IN RESTROOM. EXTEND CIRCUIT TO LIGHTING IN RESTROOM. REFER TO E2.2 FOR MORE INFORMATION. MOTORIZED DAMPER BY MECH. CONTRACTOR. PROVIDE 120V POWER (CONNECT TO NEAREST NON UPS RECEPTACLE CIRCUIT). PROVIDE RELAY TO INTERLOCK WITH FCU CONTROLS SO DAMPER OPENS WHEN FCU IS IN OPERATION. RELAY TO HAVE 24V CONTROL COIL AND CONTACTS RATED AT 120V, 10A. REVIEWDFOR COMPLICE WITH NFPA70-NEC APR Ai-Ni7 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 1 1 2014 PERMIT CENTER Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 J ISSUES & REVISIONS No. Date Description 02/17/2014 ISSUE FOR PERMIT 03/28/2014 ADDENDUM 1 SHEET TITLE ELECTRICAL POWER PLAN DRAWN: WAM REVIEWED: RWB PROJECT NO.: C1047.00 SHEET NO. E2.1 J PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. (3) 111 II 11 11 II II 11 III 11 ill III III 1 E RE -ACTION H8E ' ° 89 SF 14) GEN01000 (60001) GEN02000 (600K4^, O --s-1111°Mmalloo • 11111 IIIIINis§;MI iMI i k•€UIf1M INS!iiMM'pu!•s NUM • fib 1111:1• +:MI IN MI - A 4 X El alt MI, COLD AISLE COLD AISLE SHELL HOT AISLE COLD AISLE STAG - 117 283 S DATA CENTER 9 I to 0 S IQ� (i 16 v I 4. I : fI I L J -71 r'; a xm HOT A,lISLE L L`L_�_1 100. 100. 100 )01. �0. 100. 100. 4 I I° 1 5 1 I I I I �Y �1 ■C -1--1--1--1--1-_1-_1 JE LI- I LL ( -6 r Li L- MECHANICAL YARD L122] 27: , SF CON15091 (FUTURE) LJ J A ■M1111-11.1 AE MI •N3;'4 lilt ilriP Mip¢:N' ElIp€;Y• • MO NI ar::>• alp onare; WI di E DING MMR2 L 101 J 234 SF 15 NL H8E r LL CON14181 A Fr L- '-' 1- -TMDSC 1 MDPCI I IATSC 11000 1 10001 111000 L--J uL-_ _ MDPDJ lI I- —1 ATSD I 10001 1 I MDSD I_J 1 000 1000I L_�_J 17) ELECTRICAL LIGHTING PLAN SCALE' 1/8•-1'-0• J O O w o I Q u MECH -2 L105J 225 SF - LCPC100-4' MMR1 194 SF JA 114A 18 RR 113 58 SF ORRIDOR RR 112 58 SF V: STIBULE r t11 -' 62 SF C JE LIGHTING PLAN GENERAL NOTES 1. REFER TO SHEET E0.1 FOR ALL SYMBOLS ON THIS SHEET. 2. REFER TO SHEETS E0.2 AND E0.3 FOR ELECTRICAL SPECIFICATIONS. 3. REFER TO SHEET E4.2 FOR LIGHTING FIXTURE SCHEDULE. 4. PROVIDE (2) #10, (1) #10G IN 3/4" CONDUIT FOR ALL LIGHTING CIRCUITS. 5. COORDINATE INSTALLATION OF LIGHTING FIXTURES WITH OTHER TRADES. 6. OCCUPANCY SENSOR WIRING INDICATED ON PLANS IS INDICATIVE OF OCCUPANCY SENSORS, POWER PACKS AND LIGHTING CIRCUITS INSTALLED AS A SYSTEM. REFER TO MANUFACTURER'S DATA FOR EXACT WIRING REQUIREMENTS. LIGHTING PLAN KEYED NOTES O LIGHTING FIXTURES G TO BE CONTROLLED VIA REMOTE MOUNTED PHOTOCELL FIELD COORDINATE LOCATION OF PHOTOCELL TO AVOID CYCLING OF FIXTURE DUE TO ADJACENT LIGHTING. 02 FIXTURE TO REMAIN UNSWITCHED FOR EGRESS/NIGHT LIGHTING. TYPICAL. 0 OCCUPANCY SENSOR TYPE "OS1 ", LEVITON MODEL NO. OSWLR-IoW. TYPICAL LOWERCASE LETTER ADJACENT TO DEVICE AND LIGHT FIXTURE DENOTES SWITCHING GROUP SENSOR CONTROLS. 04 POWER PACK TYPE "OSP", LEVITON MODEL N0. OSP2O-RDH 0 POWER PACK TYPE "OSA', LEVITON MODEL NO. OSA20-R00 ADD A RELAY. O LIGHTING REQUIRED AT DOORS TO MEET 5.0 FOOTCANDLES © DOOR AND 2.0 FOOTCANDLES WITHIN 15' RADIUS OF EXIT. CONTRACTOR SHALL SUBMIT FOOTCANDLE CALCULATIONS TO CONFIRM PRIOR TO INSTALLATION OF FIXTURE. FIXTURE SHALL ALSO BE A FULL CUTOFF DESIGN, DARK SKY COMPLIANT. TYPICAL OF 2 TYPE JE FIXTURES. 0 FIXTURE SHALL BE A FULL CUTOFF DESIGN, DARK SKY COMPLIANT. TYPICAL OF 4 TYPE G FIXTURES. AREA OF WORK REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC APR 17 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 1 1.2014 PERMIT CENTER Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 ISSUES & REVISIONS No. Date Description 02/17/2014 03/28/2014 ISSUE FOR PERMIT ADDENDUM 1 SHEET TITLI3 ELECTRICAL LIGHTING PLAN J r DRAWN: WAM REVIEWED: RWB PROJECT NO.: C1047.00 SHEET NO. E2.2 KEYPLAN PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. ( 13 ) (14) 15) (16 17) LOADING DOCK L115 J 630 SF FCU03000 FP PRE-AC;BION L 116 J FD_2 89 SF COLD AISLE COLD AISLE HOT AISLE COLD AISLE HOT AISLE --_ MBCC1 GEN01000 GEN02000 (600KW) (6000 --T 1 UPSC1000 I BATT. I BATT. I BATT. I I@ FUT. CRA15000 @ I L FRONT -1__1--1- DATA CENTER PHASE II II I III III I I 1000 1000 FRONT --I-----1-----1 I BA T. I STAGE L 117 J 283 SF LANDING L.103 J 233 SF (13) ( 14 ) (15 SB( 1000 FRONT CON14081 CON13071 GSB( 2000 FRONT 01000 i KUN I FRONT � -'�MDPCI - UPSB1000 BATT. BATT. BATT.10001 FiAo-T.05--0C-LTI I MDSC1ATSEMDSB 1L1000 J 100C 1000 uL_J [1 _ — MDPD1 - - BATT. BATT. BATT. UPSA1000 11 I� ATSD I wool I M000 11000 I M000 ATSA 1000 CDl�RIT CDf1AIT TL--�-J FRONT FKUNII-KUNI FRONT FRONIT 4 4 4 4 PDUD1000 PDUC1000 PDUB1000 PDUP1000 41111U111 I) Ike ++ 200. ++ 200.■�200. 200. 200. '00. 200. 200. 200. 10 ++ �.� 3 rl612 ��s��rr■�Ila� COLD AISLE HOT AISLE COLD AISLE T T T T T 400.1400.1400. 1400.1400.1400. HOT AISLE DA A HALL 1 100 TTTT� 400.1400.1400.14C0.1400. I I I 500. 1500. 1500. 15C0.1500. I T-TT T-TT T TIT -TT -TT Tr- -1 0.1600. 600.1600.1600.1600.1600.16 00.1600.1600.1600.16 C 0.1600.1 T T 0.1100.1700.1700. T T T T T 700.1700.1700.1700.1700.1700. COLD AISLE TTT-TT -1 700.1700.1700.17C 0.1700.4 - (16) (17) ELECTRICAL GROUNDING PLAN SCALE' 1/8'-1'-O' CRA07000 ME H -2 05 5 SF MMR1 L 109 J 194 SF JAN 114 j, c0 18 18 112 58 SF CORRIDOR L 1 o8 J 1023 SF LANDING L 106 J FCU2000 429 SF LOBBY [ 110.1 J FCU 1000 258 SF VESTIBULE Lill 62 SF 19 GROUNDING PLAN KEYED NOTES GROUND TEST WELL LOCATION. COORDINATE LOCATION WITH EXISTING AND NEW UNDERGROUND CONDUITS/UTILITIES. PROVIDE COMPRESSION LUG BOLTED TO FUEL TANK FOR GROUNDING CONNECTION. TYPICAL PROVIDE EXOTHERMIC CONNECTION TO REBAR LOCATED IN CONCRETE SLAB. PROVIDE TEN FEET OF COILED CONDUCTOR FOR CONNECTION TO FUTURE EQUIPMENT. PROVIDE 16x16x8 N3R PVC BOX FOR PROTECTION OF CONDUCTOR. TYPICAL 10'-0" x 3/4" COPPER CLAD STAINLESS STEEL GROUND ROD. TYPICAL GROUNDING CONNECTION TO RAISED FLOOR PEDESTAL, TYPICAL RAISED FLOOR GROUNDING CONDUCTOR, TYPICAL. CONNECTION TO HVAC EQUIPMENT. PROVIDE BONDING STRAPS AROUND SUPPLY AND RETURN AIR FLEXIBLE CONNECTIONS. TYPICAL. CONNECTION TO METAL DOOR FRAME. TYPICAL. GROUND BAR "MSG01000" GROUND BAR "PGP01000" GROUND BAR "EFG01000" GROUND BAR "RFG01000" GROUND BAR "EFG02000" GROUND BAR "EFG03000" COORDINATE LOCATION WITH EXISTING AND NEW UNDERGROUND CONDUITS/UTILITIES. CONNECTION TO BUILDING STEEL. TYPICAL CONNECTION TO RPP. TYPICAL. GROUNDING PLAN GENERAL NOTES 1. FOR GROUNDING ONE -LINE DIAGRAM, REFER TO SHEET E1.2. 2. REFER TO SHEET E3.1 FOR GROUNDING DETAILS. 3. NOT ALL CONDUCTORS INDICATED ON THIS PLAN. REFER TO 1/E1.2 FOR MORE INFORMATION. CONDUCTOR SIZES INDICATED ON 1/E1.2. 4. SEE 1/E1.2 FOR CONDUCTOR TERMINATION LOCATIONS AT EACH GROUND BAR. CONDUCTORS SHALL BE TERMINATED AT GROUND BARS PER 1/E1.2. 5. COORDINATE EXACT LOCATION OF GROUND CONDUCTOR TIE IN EQUIPMENT WITH EQUIPMENT SUBMITTALS. PROVIDE LUGS AS REQUIRED. 0 Iss AREA OF WORK REVIEWED FOR H COMPLIANCE WITH NFPA70-NEC APR 17 2014 City of.Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 1 1 2014 PERMIT CENTER Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 J J 0) J ir ISSUES & REVISIONS ,N No. Date Description 1 02/17/2014 ISSUE FOR PERMIT A03/28/2014 ADDENDUM 1 J SHEET TITLE ELECTRICAL GROUNDING PLAN p DRAWN: WAM REVIEWED: RWB PROJECT NO.: C1047.00 SHEETH° 2.3 KEYPLAN PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. NORTHEAST CORNER OF BUILDING EQUIPMENT YARD SCREEN WALL TOP OF PARAPET ROOF LINE BEYOND (VARIES) BOTTOM OF JOIST (VARIES) ELECTRICAL SS EQUIPMENT YARD SCREEN WALL FUT. GSB02000 SECT. (INSIDE) r GSB01000 (INSIDE) 111111 111111 111111 111111 111111 II II 111111 111111 111111 111111 111111 111111 IIIW I lbb bbl�l UIW 11111.1 J llI j FUT. j I SECT. I I I FINISHED FLOOR FINISHED GRADE NORTH WALL ELECTRICAL ELEVATION SCALE' NONE ELEVATION KEYED NOTES O1 NEMA 3R PULL BOX ON EXTERIOR OF BUILDING SIZED PER NEC. ALL CONDUCTORS ROUTED THROUGH PULL BOX SHALL HAVE 600V INSULATION. TYPICAL. PROVIDE BARRIERS BETWEEN FEEDERS/BRANCH CIRCUITS AND CONTROL/BMS WIRING. 0 CONDULET ENTRIES INTO BUILDING. CORE DRILL EXTERIOR OF BUILDING FOR CONDUIT ENTRY INTO BUILDING. PROVIDE LINK -SEAL WEATHERPROOFING OF ALL CORE DRILLS. TYPICAL. NEMA 1 PULL BOX ON INTERIOR OF BUILDING SIZED PER NEC. ALL CONDUCTORS ROUTED THROUGH PULL BOX SHALL HAVE 600V INSULATION. TYPICAL. PROVIDE BARRIERS BETWEEN FEEDERS/BRANCH CIRCUITS AND CONTROL/BMS WIRING. CONDUITS ROUTED UNDERGROUND TO GENERATORS. COORDINATE ROUTING WITH ALL OTHER UTILITIES. MAINTAIN MINIMUM OF 12'-0" BETWEEN FINISHED FLOOR AND BOTTOM OF CONDUIT RACKS. LOADING DOCK L115 J 630 SF FCU03000 • PRE -AG I ION L116 J FD- 89 SF .: FCU04000 SHELL L 119 3283 SF GEN01000 (600K'w) 1 GEN02000 (600KW) c M L u gab . Fr ( IL 0 O c0 M : CHAN I CAL RD 2784 S IN1'171 f p./EXF01000 (ON ROOF) nth, IN •tp A IN iNI v IN 414 IN41;i-:,.. Maldi •N •ic,INI1111A- ♦t .Mt.k. 5 NIVINi IN 1•411:in+ MO MAP -it NIT UPSB1000 BATT. BATT. BATT. BATT. BATT. BATT. UPSA1000 CRA08000 0 0 0 0 MECH-1 L 104 3817$F 1 i W N MECH-3 L 102 398 SF ATS ATS 3000000 El Ell 2 MMR2 L 101 J 234 SF MDSB MDSA 1000 P 1 0 P C1 0 PD 81 0 PD Al 0 MIN . 100. 100. 7 8 100. 1 0 200. 200. 200. '01. 200. 200. 200. 10. 20200. 3 4 5 6 7 8 9 0 11 12 DATA H 100 3756 ELECTRICAL CONDUIT PLAN SCALE' 1/8•-1'-0• CRA07000 _P. ANNE, mIiYdi al: Nit EP MECH -2 L 105 225 SF MMR1 L 109 194 SF MECH-4 L 107 J 469 SF LU w CO ■ NORTHEAST CORNER OF BUILDING RR 9 LANDING L 106 J FCU2000 429 SF ■ 1 Iss. 01 1 L11 000 0 0 rn LOBBY [ 110.1 J FCU1000 258 SF I SECO1 000 {5xAGE LI QQ 0.2 g1SF RR 112 58 SF VESTIBULE L 111 J 62 SF CONDUIT ROUTING PLAN GENERAL NOTES 1. REFER TO SHEET E0.1 FOR GENERAL NOTES AND SYMBOL LEGEND. 2. THIS DRAWING'S INTENDED USE IS TO ASSIST IN THE ROUTING OF UNDERGROUND AND INTERIOR TO THE BUILDING CONDUITS AND SETS MINIMUM REQUIREMENTS FOR FUTURE CONDUITS. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMING THE EXACT CONDUIT QUANTITIES AND REQUIREMENTS. 3. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL SEISMIC BRACING AND DESIGN, WHERE REQUIRED BY LOCAL AUTHORITIES. 4. ALL FEEDERS ARE TO BE SUPPORTED FROM THE FLOOR. SUPPORTING FROM THE CEILING/ROOF IS NOT ALLOWED WITHOUT PRIOR APPROVAL BY STRUCTURAL ENGINEER. CONDUIT ROUTING PLAN KEYED NOTES 0 O O FEEDER CONDUITS TO RPP'S ROUTED UNDER RAISED FLOOR. CONTRACTOR TO KEEP CONDUITS AS CLOSE TO BOTTOM OF SLAB AS POSSIBLE. PROVIDE OFFSETS/SADLES AS NECESSARY. UNDERGROUND FEEDER/CONTROLS CONDUITS FROM GENERATORS TO BUILDING. STUB CONDUITS UP AT EXTERIOR OF BUILDING AND ROUTE OVERHEAD TO INTERIOR. UNDERGROUND SERVICE LATERAL CUT AND PATCH SLAB TO ORIGINAL SPECIFICATION. REVIEWED FOR H COMPLIANCE WITH NFPA70 APR 17 2014 City oTukwila BUILDING D RECEIVED CITY OF TUKWILA Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 O cj D: EDCSEA01 LU w 1101 I ISSUES & REVISIONS No. Date Description 1 02/17/2014 ISSUE FOR PERMIT © 03/28/2014 ADDENDUM 1 MEET TITLE ELECTRICAL CONDUIT PLAN DRAWN: WAM REVIEWED: RWB PROJECT NO.: C1047.00 SHEETNO 2.4 KEYPLAN J PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. CON30C31 LCPC10 )0-38,40,42 3#10, #10G., 3/4"C. LCPC1000-19 CON31041 LCPD1000-38,40,42 3#10, #10G., 3/4"C. CON01011 CON02012 CON03021 CON04022 CON05031 CON06032 EXF01000 MDPC1000-4 MDPB1000-4 O MDPA1000-2 ® ELECTRICAL ROOF PLAN SCALE. 1/8•-1'-0• CON28021 CON27C11 MDPA1000-10 LCPC 1000-28,30,32 3#10, #10G., 3/4"C. LCPD1000-28,30,32 11-t-#1-007,-3/4"C. ROOF PLAN GENERAL NOTES 1. REFER TO SHEET E0.1 FOR ALL SYMBOLS ON THIS SHEET. 2. REFER TO SHEETS E0.2 AND E0.3 FOR ELECTRICAL SPECIFICATIONS. 3. SEE ONE LINE DIAGRAMS AND FEEDER SCHEDULES FOR FEEDER SIZES AND EQUIPMENT SIZES NOT INDICATED ON THIS PLAN. 4. SEE MECHANICAL PLANS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OF HVAC EQUIPMENT. 5. ALL SINGLE PHASE BRANCH CIRCUITS ARE (3) #12, 3/4" C UNLESS IDENTIFIED OTHERWISE ON THIS PLAN, ELECTRICAL ONE LINE DIAGRAMS, OR AS REQUIRED BY SHEET E0.1 TO BE INCREASED DUE TO VOLTAGE DROP PER N.E.C. NEUTRAL CONDUCTORS SHALL NOT BE SHARED. 6. FIELD VERIFY EXACT LOCATION OF ALL MECHANICAL EQUIPMENT TERMINATIONS. 7. PROVIDE CONTROLS/MONITORING WIRING FOR MECHANICAL EQUIPMENT. COORDINATE EXACT REQUIREMENTS WITH DETAILS AND MECHANICAL CONTRACTOR. ROOF PLAN KEYED NOTES O REFER TO ONE LINE DIAGRAM FOR SIZING. O ROUTE POWER AND CONTROLS WIRING ALONGSIDE REFRIGERANT PIPING. UTILIZE SAME ROOF PENETRATION. 0 PROVIDE NEW 30/3/NF/N3R HEAVY DUTY DISCONNECT SWITCH. 0 PROVIDE NEW WEATHERPROOF, DUPLEX, GFI RECEPTACLE. SUPPORT INDEPENDENT OF MECHANICAL EQUIPMENT. O MECHANICAL PIPING ROOF PENETRATION. REVIEWED .FOR -- COMPLIANCE WITH NFPA 70 - NEC APR 17 2014 City of.Tukwila BUILDING DIVISION AREA OF WORK RECEIVED CITY OF TUKWILA APR 1 1 2014 PERMIT CENTER f Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 x CD C O U D: EDCSEA01 LU CI) i ISSUES & REVISIONS No. Date Description 1 02/17/2014 ISSUE FOR PERMIT © 03/28/2014 ADDENDUM 1 J SHEE7TTiTLE ELECTRICAL ROOF PLAN r J DRAWN: WAM REVIEWED: RWB PROJECT NO.: C1047.00 SHEETNO. 2.5 KEYPLAN PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. 0 w' SWITCH I EPO SYSTEM COMPONENTS E.P.O. STATION SWITCH(ES) SHALL BE A SQUARE D MODEL #9001K15 GLASS BREAK OPERATOR #9001KA1 CONTACT BLOCK. THE E.P.O. SWITCH SHALL BE MOUNTED TO MATCH OTHER DEVICES HEIGHTS. PROVIDE RED LAMACOID NAMEPLATE 2"Wx4"H WITH 3/8" HIGH WHITE LEI IERING (2 LINES) LABELED "EMERGENCY POWER OFF". THERE SHALL BE (1) EPO SWITCHES AT EACH LOCATION. THE EPO SWITCH(ES) SHALL OPERATE SUCH THAT WHEN THE GLASS DISK IS BROKEN THE OPERATOR IS NO LONGER HELD IN A DEPRESSED POSITION. THE CONTACTS CLOSE, OPERATING THE EPO SYSTEM WHEN BOTH SWITCHES AT A STATION HAVE BEEN ACTIVATED. PROVIDE FIVE REPLACEMENT GLASS DISKS. THE ENCLOSURE SHALL BE A FIKE EPSMS SINGLE DOOR, WALL MOUNT ENCLOSURE WITH HINGED DOOR, LOCK KIT ACCESSORY, NEMA 1 SURFACE MOUNTED. PROVIDE RED LAMACOID NAMEPLATE WITH 3/8" HIGH WHITE LEI I ERING (2 LINES) LABELED "EP001000". EPO SYSTEM OPERATION THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIALS REQUIRED TO FURNISH A COMPLETE AND OPERATIONAL EPO SYSTEM. EPO SWITCHES SHALL BE INTERFACED WITH ALL CRAC UNITS, RPPS, AND THE FIRE ALARM PANEL THE FOLLOWING ARE CONTROL FUNCTIONS FOR THE SPACE: 1. THE SYSTEM SHALL PROVIDE CONTROL TO SHUT DOWN ALL DATA CENTER CRAC UNITS AND CLOSE ALL FIRE/SMOKE DAMPERS IN THE EVENT A STAGE TWO ALARM RELAY IS ACTIVATED (TWO SMOKE DETECTORS IN ALARM, VIA FIRE ALARM CONTROL PANEL). 2. THE SYSTEM SHALL PROVIDE CONTROL TO SHUT DOWN ALL DATA CENTER CRAC UNITS, ALL UPSS, IN THE EVENT TWO EPO SWITCHES ARE ACTIVATED. 3. THE SYSTEM SHALL PROVIDE CONTROL TO SHUT DOWN ALL DATA CENTER CRAC UNITS, ALL UPSS IN THE DATA CENTER IN THE EVENT THE WATER RELEASE RELAY IS ACTIVATED. CONTRACTOR SHALL BE RESPONSIBLE FOR INTERFACING WITH THE BUILDING FIRE ALARM SYSTEM. 4. THE SYSTEM SHALL BE BUILT WITH ENOUGH CAPACITY TO ACCOMMODATE ALL FUTURE UPSS, CRACS UNITS, ETC. AS INDICATED ON EPO. WIRING DIAGRAM THIS SHEET. 5. REFER TO THE EPO WIRING DIAGRAM THIS SHEET FOR ADDITIONAL INFORMATION. CONTROL POWER FOR THE EPO SYSTEM SHALL BE DERIVED FROM A NORMAL POWER SOURCE. UPS POWER SHALL NOT BE USED. 6. ALL EPO BREAKGLASS COMPONENTS AND/OR ANY FIRE ALARM SIGNAL FUNCTIONS MUST BE RESTORED TO NORMAL BEFORE EPO RESET BUTTON CAN RESTORE THE EPO SYSTEM TO NORMAL CONDITION. FUTURE AUTOMATIC TRANSFER "ATSD1 000" C 0 0 FUTURE AUTOMATIC TRANSFER SWITCH "ATSC1000" 0 0 0 0.• riv NEW AUTOMATIC TRANSFER SWITCH "ATSB1 000" M023 M022 N 0 0 NEW AUTOMATIC TRANSFER SWITCH "ATSA1000" ti (M025) -(M026) M024 (MO21 MASTER CONTROL PANEL PLC01000 n r. n 0) O N 0 o 0 J F....)J O N 00 O O 0 GENERATOR SWBDS 'GSB01000' 0 rn 0 c»J 0 0 u 0 N 0 0 00 N 0 GENERATOR SWBDS 'GSB02000' 0 BMS M002) E.P.0 ACTIVATION INPUTS REMOTE MONITORING (TO BMS PANEL IN ISS ROOM) EPO STATION #1 AT SERVICE DISCONNECT ROOM 14 H�H /14 EPO STATION #1 DATA CENTER H�H _#14 /14. EPO STATION #2 DATA CENTER /14 _#14 FIRE ALARM CONTROL PANEL 14 _#14 EPO ACTIVATION ALARM J14 /14 SYSTEM IN BYPASS ALARM OPT. STANDBY 550kW/687.5KVA GENERATOR GEN01000 480Y/277V, 30, 4W, 0.80PF 100% (MOOD-- (M004) (M003) (MOO6) (M005) (M008) (M007) (M030) (M029 (M032) M031 M010 M009) M012) MO11) M028 (M027) (M013) (M015) (M014 M020 0 _#14 114 EPO SYSTEM EP001000 SYSTEM RESET/LNAP TEST KEY SWITCH KEY SWITCH NORMAL OVERRIDE O MAINTENANCE OVERRIDE KEY SWITCH 2ND ALARM ACTIVATION (AC EPO) I I L _ J EP.O. ACTIVATION (Ac at UPS EPO) SILENCE NOT USED J J DIAGRAM NOT TO SCALE OPT. STANDBY 550kW/687.5KVA GENERATOR GEN02000 480Y/277V, 30, 4W, 0.80PF M017) FUT. OPT. STANDBY 550kW/687.5KVA GENERATOR GEN03000 480Y/277V, 30, 4W, 0.8OPF (MO18 r • 5500N #14 TO UPSA1000 #14 #14 TO UPSB1000 #14 #14 #14 FUTURE UPSC1000 #14 #14 FUTURE UPSD1000 #14 #14 CRA01000 TERMINALS. ( 91 }---• -,H'• (92}----(38) { 38 (37. #14 37 CRA02000 TERMINALS 91 92) ( 38 ) #14 CRA03000 TERMINALS - +--- • —f-- { 92 }---{ 38 (37 FUT. OPT. STANDBY 550kW/687.5KVA GENERATOR GEN04000 480Y/27N, 30, 4W, 0.80PF 1000/3 "') 100% Ti fT1 MO191r 0 (M015) (M 016) 550kW1 , 41 " ) ✓✓ 100%1000/3 M' ITT 1 1 I FUT. OPT. STANDBY 550kW/687.5KVA GENERATOR GEN05000 480Y/277V, 30, 4W, 0.80PF r (M033) KEYED NOTES 0 GENERATOR FEEDER. REFER TO FEEDER SCHEDULE ON SHEETS E4.1 AND E4.2 FOR MORE INFORMATION. 0 EXTEND TO THE ELECTRICAL ROOM. REFER TO SHEET E2.1 FOR LOCATION. 0 FIELD COORDINATE EXACT TERMINATION LOCATION. O FOR FUTURE GENERATORS, STUB CONDUITS INTO A 1NEMA 1 PULLBOX INSIDE ELECTRICAL ROOM. REFER TO SHEETS E2.0 AND E2.1 FOR MORE INFORMATION. 0 REFER TO XYZ FOR BMS LOCATION. (MO 16) GENERATOR CONTROLS WIRING REQUIREMENTS SCALE: NTS FUTURE CRA TERMINALS }-� •,K• • -{ 92 }----C 38 ) C37) FUT. OPT. STANDBY 550kW/687.5KVA GENERATOR GEN06000 480Y/27N, 30, 4W, 0.80PF 550kW 1000/3 "'‘, 100% 'r- 1 I 550kW • •• • 1--yO.. 1000/3 "') 100% M'. -I- I 0 r i� E.P.0 ACTIVATION OUTPUTS STAGE 2 ONLY OUTPUTS -REVIEWED _FOR -- - COMPLIANCE WITH NPPA70-NEC APR 17 2014 City of Tukwila BUILDING DIVISION GENERATOR SYSTEM CONTROL WIRING SCHEDULE MARK FROM TO CONTROL WIRING SPECIFICATIONS CONDUIT SIZE NUMBER OF SETS NOTES M001 GEN01000 PLC01000 (2) CAT 5E (6E) 1-1/4" 1 1, 5 M002 GEN01000 PLC01000 (12) #14, (4) #12 1-1/4" 1 1, 5 M003 GEN02000 PLC01000 (2) CAT5E (6E) 1-1/4" 1 1, 5 M004 GEN02000 PLC01000 (12) #14, (4) #12 1-1/4" 1 1, 5 M005 FUT. GEN03000 PLC01000 PULLSTRING ONLY 1-1/4" 1 2, 3 M006 FUT. GEN03000 PLC01000 PULLSTRING ONLY 1-1/4" 1 2, 3 M007 FUT. GEN04000 ' PLC01000 PULLSTRING ONLY 1-1/4" 1 2, 3 M008 FUT. GEN04000 PLC01000 PULLSTRING ONLY 1-1/4" 1 2, 3 M009 GEN01000 JUNCTION BOX (4) #14 THHN 1-1/4" 1 1, 5 M009A JUNCTION BOX GSB02000 (2) #14 THHN 1" 1 1, 5 MOO9B JUNCTION BOX GSB01000 (2) #14 THHN 1" 1 1, 5 M010 GEN02000 JUNCTION BOX (4) #14 TFIHN 1-1/4" 1 1, 5 M010A JUNCTION BOX GSB02000 (2) #14 THHN 1" 1 1, 5 M010B JUNCTION BOX GSB01000 (2) #14 THHN 1" 1 1, 5 M011 FUT. GEN03000 JUNCTION BOX PULLSTRING ONLY 1-1/4" 1 2, 3 M011A JUNCTION BOX GSB02000 PULLSTRING ONLY 1" 1 2, 3 M011 B JUNCTION BOX GSB01000 PULLSTRING ONLY 1" 1 2, 3 M012 FUT. GEN04000 JUNCTION BOX PULLSTRING ONLY 1-1/4" 1 2, 3 M012A JUNCTION BOX GSB02000 PULLSTRING ONLY 1" 1 2, 3 M012B JUNCTION BOX GSB01000 PULLSTRING ONLY 1" 1 2, 3 M013 GEN01000 ELECTRICAL ROOM PULLSTRING ONLY 1-1/4" 1 2, 3 M014 GEN02000 ELECTRICAL ROOM PULLSTRING ONLY 1-1/4" 1 2, 3 M015 FUT. GEN03000 ELECTRICAL ROOM PULLSTRING ONLY 1-1/4" 1 2, 3 M016 FUT. GEN04000 ELECTRICAL ROOM PULLSTRING ONLY 1-1/4" 1 2, 3 M017 GEN01000 GEN02000 (16) #14 THHN 1-1/4" 1 1, 5 M018 GEN02000 FUT. GEN03000 PULLSTRING ONLY 1-1/4" 1 2 M019 FUT. GEN03000 FUT. GEN04000 PULLSTRING ONLY 1-1/4" 1 2 M020 FUT. GEN06000 GEN01000 PULLSTRING ONLY 1-1/4" 1 2 M021 PLC01000 JUNCTION BOX (20) #14 THHN 1-1/4" 1 1, 5 M021A JUNCTION BOX GSB02000 (10) #14 THHN 1 1 2, 3 M021B JUNCTION BOX GSB01000 (10) #14 THHN 1 1 1, 5 M022 ATSD1000 PLC01000 (12) #14 THHN 1 1 1, 5 M023 ATSC1000 PLC01000 (12) #14 THHN 1 1 1, 5 M024 ATSB1000 PLC01000 (12) #14 THHN 1 1 1, 5 M025 ATSA1000 PLC01000 (12) #14 THHN 1 1 1, 5 M026 PLC01000 BMS (2) CAT 5E (6E) 1-1/4" 1 1 M027 FUT. GEN05000 JUNCTION BOX PULLSTRING ONLY 1-1/4" 1 2, 3 M027A JUNCTION BOX GSB02000 PULLSTRING ONLY 1" 1 2, 3 M027B JUNCTION BOX GSB01000 PULLSTRING ONLY 1" 1 2, 3 M028 FUT. GEN06000 JUNCTION BOX PULLSTRING ONLY 1-1/4" 1 2, 3 M028A JUNCTION BOX GSB02000 . PULLSTRING ONLY 1" 1 2, 3 M028B JUNCTION BOX GSB01000 PULLSTRING ONLY 1" 1 2, 3 M029 FUT. GEN05000 PLC01000 PULLSTRING ONLY 1-1/4" 1 2, 3 M030 FUT. GEN05000 PLC01000 PULLSTRING ONLY 1-1/4" 1 2, 3 M031 FUT. GEN06000 PLC01000 PULLSTRING ONLY 1-1/4" 1 2, 3 M032 FUT. GEN06000 PLC01000 PULLSTRING ONLY 1-1/4" 1 2, 3 M033 FUT. GEN04000 FUT. GEN05000 PULLSTRING ONLY 1-1/4" 1 2 M034 FUT. GEN05000 FUT. GEN06000 PULLSTRING ONLY 1-1/4" 1 2 NOTES: 1) ALL WIRING SHALL BE CONFIRMED WITH GENERATOR SUPPLIER PRIOR TO INSTALLATION. 2) PROVIDE PERMANENT CONDUIT CAPS, TEMPORARY CONDUIT CAPS NOT ALLOWED. 3) EXTEND CONDUIT TO INTERIOR PULLBOX FOR READY EXTENSION TO FUTURE EQUIPMENT. REFER TO SHEETS E2.0 4) FIELD VERIFY EXACT TERMINATION LdCA11oN AT EITHER GSB01000 OR GSB02000. 5) PROVIDE 600V INSULATION. , AND E2.1. 10400 Rodgers Road HOUSTON, TEXAS 77070 Ph: 281-374-8644 Fax: 281-374-8992 Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 1• X CD Cm- O (:D C:15) W cn 0 uJ 0 I"- ISSUES & REVISIONS No. Date Description 1 02/17/2014 ISSUE FOR PERMIT A03/28/2014 ADDENDUM 1 RECEIVED CITY OF TUKWILA APR 1 1 2014 PERMIT CENTER J SHEET 'RILE ELECTRICAL DETAILS DRAWN: WAM REVIEWED: . RWB PROJECT NO.: C1047.00 SHEET NO. E3.4 PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. J LIGHT FIXTURE SCHEDULE MARK LAMPS VOLTAGE /WATTS DESCRIPTION MANUFACTURERS CATALOG NUMBER MOUNTING REMARKS NO. TYPE A 1 LED 120V / 14W ALL MOUNTED LINEAR LIGHTING FIXTURE WITH ALUMINUM FINISH ARCHITECTURAL LIGHTING WORKS ALW WLPD35-4-1-HP10-3500K-LLED-EXT-AL WALL MOUNTING HEIGHT- 8'6" AFF. FIELD VERIFY WITH BCEI PRIOR TO ROUGH -IN AE 1 LED 120V / 14W ALL MOUNTED LINEAR LIGHTING FIXTURE WITH ALUMINUM FINISH, EMERGENCY BALLAST ARCHITECTURAL LIGHTING WORKS ALW WLPD35-4-1-HP10-3500K-LLED-EXTAL-EM WALL MOUNTING HEIGHT - 8'6" AFF. FIELD VERIFY WITH BCEI PRIOR TO ROUGH -IN, PROVIDE EMERGENCY BALLAST. 'NL' ADJACENT TO FIXTURE DENOTES UNSWITCHED TO SERVE AS NIGHT/EGRESS LIGHT. B 2 LED UNIVERSAU107W - URFACE MOUNTED LINEAR LENSED STRIP LIGHTING FIXTURE METALUX METALUX 8TSNLED-LD1-115-LC-UNV-L850-CD2-U SURFACE EIGHT FOOT LONG FIXTURE MOUNTED TO CEILING SYSTEM. CLEAR LENS, 2 LED DRIVERS BE 2 LED UNIVERSAL/107W - URFACE MOUNTED LINEAR LENSED STRIP LIGHTING FIXTURE, EMERGENCY BALLAST METALUX METALUX8TSNLED-LD1-115-LC-UNV-L850-CD2-U-EL SURFACE EIGHT FOOT LONG FIXTURE MOUNTED TO CEILING SYSTEM. CLEAR LENS, 2 LED DRIVERS. PROVIDE EMERGENCY BALLAST. MOUNTING HEIGHT - 8'6" AFF. FIELD VERIFY WITH BCEI PRIOR TO ROUGH -IN, PROVIDE EMERGENCY BALLAST. 'NL' ADJACENT TO FIXTURE DENOTES UNSWITCHED TO SERVE AS NIGHT/EGRESS LIGHT. C 1 LED UNIVERSAU35W LAY -IN TROFFER METALUX METALUX22EN-LD1-34-UNV-L840-CD1-U RECESSED CE 1 LED 120V / 35W LAY -IN TROFFER, EMERGENCY BALLAST METALUX METALUX22EN-LD1-34-120-EL14-L835-CD1-U RECESSED PROVIDE EMERGENCY BALLAST. INSTALL REMOTE MOUNTED TEST SWITCH G 1 LED UNIVERSAU54W , ALL MOUNTED FLOOD LIGHT McGRAW EDISON IST B02-LED-E1-BL4-GM WALL MOUNT TOP OF FIXTURE 12" BELOW TOP OF SCREEN WALL. FIXTURE SHALL BE FULL CUTOFF. H8 2 LED 120V / 107W • FOOT SURFACE MOUNTED LINEAR LENSED STRIP LIGHTING FIXTURE METALUX METALUX 8TSNLED-LD1-115-LC-UNV-L850-CD2-U SUSPENDED SUSPENDED UTILIZING UNISTRUT SUPPORT H8E 2 LED 120V / 107W 8 FOOT SURFACE MOUNTED LINEAR LENSED STRIP LIGHTING FIXTURE, EMERGENCY BALLAST METALUX METALUX 8TSNLED-LD1-115-LC-UNV-EL-L850-CD2-U SUSPENDED SUSPENDED UTILIZING UNISTRUT SUPPORT, PROVIDE EMERGENCY BALLAST JE 2 LED 120V / 3W RIOR WALL MOUNTED EMERGENCY/EGRESS LIGHTING FIXTURE WITH REDUNDANT LED'S DUAL-LITE DUAL LITE PG Z-HTR WALL MOUNT. ONE FOOT ABOVE DOOR, CONTAINS BATTERY HEATER FOR COLD OPERATION. BRONZE FINISH X1 N/A LED 120V / 4W •' NIVERSAL MOUNT EDGE LIT EXIT LIGHT COOPER INDUSTRIES EEX 7-X R WALUCEILING X1 INDICATES SINGLE FACE, X2 INDICATES DOUBLE FACE, PROVIDE ARROWS AS INDICATED, RED FEEDER SCHEDULE MARK FROM TO FEEDER CONDUCTOR QUANTITY AND SIZE CONDUIT SIZE NUMBER OF SETS FEEDER AMPERAGE REMARKS U001 UTILITY UTILITY TRANSFORMER N/A 6" 2 N/A NOTE 1 U002 UTILITY TRANSFORMER UTILITY METERING CABINET (3) 750kCM, (1) 750kCM N. 4" 8 4000 NOTE 2, 7 001 UTILITY METERING CABINET MSB01000 (3) 500kCM; (1) 500kCM N., (1) 500kCM G 4" 11 4000 NOTE 2 002 MSB01000 ATSA1000 (3) 400MCM, (1) #4/0 G. 3-1/2" 5 1600 003 MSB01000 ATSB1000 (3) 400MCM, (1) #4/0 G. 3-1/2" 5 1600 004 ATSA1000 MDSA1000 (3) 400MCM, (1) #4/0 G. 3-1/2" 5 1600 005 MDSA1000 MBCA1000 (3) 300MCM, (1) #1/0 G. 2-1/2" 3 800 006 MDSA1000 UPSA1000 (3) 350MCM, (1) #2/0G. 2-1/2" 3 900 007 MDSA1000 MDPA1000 (3) 300MCM, (1) #1/0 G. 2-1/2" 3 800 008 MDSA1000, MDPC1000 (3) 300MCM, (1) #1/0 G. 2-1/2" 3 800 009 MBCA1000 (SECT. 1) MBCA1000 (SECT. 2) (3) 300MCM, (1) #1/0 G. 2-1/2" 3 800 NOTE 3 010 MBCA1000 (SECT. 1) UPSA1000 (3) 300MCM, (1) #1/0 G. 2-1/2" 3 800 011 UPSA1000 MBCA1000 (SECT. 2) (3) 300MCM, (1) #1/0 G. 2-1/2" 3 800 012 MBCA1000 (SECT. 2) PDUA1000 (3) 300MCM, (1) #1/0 G. 2-1/2" 3 800 013 ATSB1000 MDSB1000 (3) 400MCM, (1) #4/0 G. 3-1/2" 5 1600 014 MDSB1000 MBCB1000 (3) 300MCM, (1) #1/0 G. 2-1/2" 3 800 015 MDSB1000 UPSB1000 (3) 350MCM, (1) #2/0G. 2-1/2" 3 900 016 MDSB1000 MDPB1000 (3) 300MCM, (1) #1/0 G. 2-1/2" 3 800 017 MDSB1000 MDPD1000 (3) 300MCM, (1) #1/0 G. 2-1/2" 3 800 018 MBCB1000 (SECT. 1) MBCB1000 (SECT. 2) (3) 300MCM, (1) #1/0 G. 2-1/2" 3 800 NOTE 3 019 MBCB1000 (SECT. 1) UPSB1000 (3) 300MCM, (1) #1/0 G. 2-1/2" 3 800 020 UPSB1000 MBCB1000 (SECT. 2) (3) 300MCM, (1) #1/0 G. 2-1/2" 3 800 021 MBCB1000 (SECT. 2) PDUB1000 (3) 300MCM, (1) #1/0 G. 2-1/2" 3 800 022 PDUA1000 RPP01000 (3) #4/0, (1) #4/0 N., (1) #2 G. 2-1/2" 2 450 NOTE 4 023 PDUA1000 RPP04000 (3) #4/0, (1) #4/0 N., (1) #2 G. 2-1/2" 2 450 NOTE 4 024 PDUA1000 BELOW RAISED FLOOR PULLSTRING 2-1/2" 2 NOTE 5 025 PDUA1000 BELOW RAISED FLOOR PULLSTRING 2-1/2" 2 NOTE 5 026 PDUB1000 RPP01000 (3) #4/0, (1) #4/0 N., (1) #2 G. 2-1/2" 2 450 NOTE 4 027 PDUB1000 RPP05000 (3) #4/0, (1) #4/0 N., (1) #2 G. 2-1/2" 2 450 NOTE 4 028 PDUB1000 BELOW RAISED FLOOR PULLSTRING 2-1/2" 2 NOTE 5 029 PDUB1000 BELOW RAISED FLOOR PULLSTRING 2-1/2" 2 NOTE 5 , 030 PDUC1000 RPP02000 (3) #4/0, (1) #4/0 N., (1) #2 G. 2-1/2" 2 450 NOTE 4 031 PDUC1000 RPP05000 (3) #4/0, (1) #4/0 N., (1) #2 G. 2-1/2" 2 450 NOTE 4 032 PDUC1000 BELOW RAISED FLOOR PULLSTRING 2-1/2" 2 NOTE 5 033 PDUC1000 BELOW RAISED FLOOR PULLSTRING 2-1/2" 2 NOTE 5 034 PDUD1000 RPP02000 (3) #4/0, (1) #4/0 N., (1) #2 G. 2-1/2" 2 450 NOTE 4 035 PDUD1000 RPP04000 (3) #4/0, (1) #4/0 N., (1) #2 G. 2-1/2" 2 450 NOTE 4 036 PDUD1000 BELOW RAISED FLOOR PULLSTRING 2-1/2" 2 NOTE 5 037 PDUD1000 BELOW RAISED FLOOR PULLSTRING 2-1/2" 2 NOTE 5 038 MDPA1000 ATSA2000 (3) #1, (1) #8 G. 1-1/2" 1 110 039 ATSA2000 CRA03000 (3) #1, (1) #8 G. 1-1/2" 1 110 NOTE 4 040 MDPA1000 ATSA3000 (3) #10, (1) #10G. 3/4" 1 30 041 ATSA3000 ERP03000/CON05031/CON06032 (3) #6, (1) #6G. 1" 1 30 NOTE 4, 6 042 PDUA1000 BELOW RAISED FLOOR PULLSTRING 2-1/2" 2 NOTE 5 043 PDUB1000 BELOW RAISED FLOOR PULLSTRING 2-1/2" 2 NOTE 5 044 PDUC1000 BELOW RAISED FLOOR PULLSTRING 2-1/2" 2 NOTE 5 045 PDUD1000 BELOW RAISED FLOOR PULLSTRING 2-1/2" 2 NOTE 5 046 MDPB1000 CRA02000 (3) #1, (1) #8 G. 1-1/2" 1 110 NOTE 4 047 MBCA1000 (SECT. 2) PDUC1000 (3) 300MCM, (1) #1/0 G. 2-1/2" 3 800 048 MDPB2000 ERP02000/CON03021/CON04022 (3) #6, (1) #6G. 1" 1 30 NOTE 4, 6 049 MBCB1000 (SECT. 2) PDUD1000 (3) 300MCM, (1) #1/0 G. 2-1/2" 3 800 050 MDPB1000 ATSA2000 (3) #1, (1) #8 G. 1-1/2" 1 110 051 MDPB1000 ATSA3000 (3) #10, (1) #10G. 3/4" 1 30 052 MDPC1000 TRNC1000 (3) #1, (1) #6 G. 1-1/4" 1 125 NOTE 4 053 TRNC1000 LCPC1000 (4) 250MCM, (1) #4 G. 2-1/2" 1 250 NOTE 4 054 MDPC1000 CRA07000 (3) #6, (1) #10 G. 3/4" 1 50 NOTE 4 055 MDPC1000 CON13071 (3) #8, (1) #8 G. 3/4" 1 20 NOTE 4, 6 056 MDPC1000 CRA01000 (3) #1, (1) #8 G. 1-1/2" 1 110 NOTE 4 057 MDPC1000 ERP01000/CON01011/CON02012 (3) #6, (1) #6G. 1" 1 30 NOTE 4, 6 058 MDPA1000 CRA09000 (3) #10, (1) #10G. 3/4" 1 15 NOTE 4 059 MDPA1000 CON26151 (3) #10, (1) #10G. 3/4" 1 15 NOTE 4, 6 060 MDPD1000 TRND1000 (3) #1, (1) #6 G. 1-1/4" 1 125 NOTE 4 061 TRND1000 LCPD1000 (4) 250MCM, (1) #4 G. 2-1/2" 1 250 NOTE 4 062 MDPD1000 CRA08000 (3) #6, (1) #10 G. 3/4" 1 50 NOTE 4 063 MDPD1000 CON14081 (3) #8, (1) #8 G. 3/4" 1 20 NOTE 4, 6 NOTES: 1) PROVIDE CONCRETE ENCASEMENT AND PULL ROPE. 2) PROVIDE CONCRETE ENCASEMENT. 3) JUMPER. 4) PROVIDE LFMC FLEXIBLE CONNECTION AT EQUIPMENT. 5) CAP BELOW RAISED FLOOR. 6) FEEDER INCREASED DUE TO EXPOSED ROUTING ON ROOF. PROVIDE GRS CONDUIT WHERE EXPOSED ON ROOF. 7) PROVIDE TWO ADDITIONAL SPARE 4" CONDUITS. UPS -BATTERY FEEDER SCHEDULE MARK FROM TO FEEDER CONDUCTOR QUANTITY AND SIZE CONDUIT SIZE NUMBER OF SETS FEEDER AMPERAGE REMARKS B001 BATA1001 UPSA1000 PROVIDED BY MANUFACTURER N/A N/A N/A CONTRACTOR INSTALLED B002 BATA1002 UPSA1000 PROVIDED BY MANUFACTURER N/A N/A N/A CONTRACTOR INSTALLED B003 BATA1003 UPSA1000 PROVIDED BY MANUFACTURER N/A N/A N/A CONTRACTOR INSTALLED B004 BATB1001 UPSB1000 PROVIDED BY MANUFACTURER N/A N/A N/A CONTRACTOR INSTALLED B005 BATB1002 UPSB1000 PROVIDED BY MANUFACTURER N/A N/A N/A CONTRACTOR INSTALLED B006 BATB1003 UPSB1000 PROVIDED BY MANUFACTURER N/A N/A N/A CONTRACTOR INSTALLED STANDBY GENERATOR FEEDER SCHEDULE MARK FROM TO FEEDER CONDUCTOR QUANTITY AND SIZE CONDUIT SIZE NUMBER OF SETS FEEDER AMPERAGE REMARKS S001 GEN01000 GSB01000/GSB02000 (4) #400MCM, (1) #2/0 G. 4" 3 1000 NOTE 1 S002 GEN02000 GSB01000/GSB02000 (4) #400MCM, (1) #2/0 G. 4" 3 1000 NOTE 1 S003 FUTURE GEN03000 GSB01000/GSB02000 PULLSTRING 4" 3 NOTE 2 S004 FUTURE GEN04000 GSB01000/GSB02000 PULLSTRING 4" 3 NOTE 2 S005 FUTURE GEN05000 GSB01000/GSB02000 PULLSTRING 4" 3 NOTE 2 S006 FUTURE GEN06000 GSB01000/GSB02000 PULLSTRING 4" 3 NOTE 2 S007 GSB01000 ATSA1000 (3) 400MCM, (1) #4/0 G. 3-1/2" 5 1600 S008 GSB02000 ATSB1000 (3) 400MCM, (1) #4/0 G. 3-1/2" 5 1600 S009 GSB01000 GSB02000 (4) 500MCM, (1) 500CM G. 4" 11 4000 NOTES: 1) PROVIDE LFMC AT CONNECTION TO GENERATOR. 2) STUB UP CONDUITS TO 18" AFG AT FUTURE GENERATOR LOCATION AND CAP. ROUTE CONDUITS TO INTERIOR JUNCTION BOX IA .01) IL( FAULT CURRENT CALCULATIONS EQUIPMENT ONE LINE REFERENCE EQUIPMENT RATING (AIC) MAXIMUM FAULT 3-PHASE (AMPS) I PASS OR I FAIL SERVICE ENTRANCE UTIL. METER CAB. E1.1 100,000 60,514 PASS MSB01000 E1.1 100,000 59,038 PASS DISTRIBUTION SYSTEM A ATSA1000 E1.1 85,000 51,111 PASS MDSA1000 E1.1 65,000 48,129 PASS MBCA1000 E1.1 65,000 41,832 PASS UPSA1000.. E1.1 65,000 41,875 PASS MDPA1000 E1.1 65,000 44,760 PASS ATSA2000 E1.1 10,000 8,942 PASS PDUA1000 E1.1 42,000 24,663 PASS RPP01000 A -SIDE E1.1 22,000 16,520 PASS RPP04000 A -SIDE E1.1 22,000 14,736 PASS DISTRIBUTION SYSTEM B ATSB1000 E1.1 85,000 53,313 PASS MDSB1000 E1.1 65,000 48,601 PASS MBCB1000 E1.1 65,000 42,897 PASS UPSB1000 E1.1 65,000 42,622 PASS MDPB1000 E1.1 65,000 42,897 PASS PDUB1000 E1.1 42,000 24,737 PASS RPP01000 B-SIDE E1.1 22,000 9,962 PASS RPP05000 B-SIDE E1.1 22,000 11,487 PASS DISTRIBUTION SYSTEM C MDPC1000 E1.1 65,000 38,671 PASS LCPC1000 E1.1 10,000 4,504 PASS PDUC1000 E1.1 42,000 24,997 PASS RPP02000 C-SIDE E1.1 22,000 10,004 PASS RPP05000 C-SIDE E1.1 _ 22,000 11,115 PASS DISTRIBUTION SYSTEM D MDPD1000 E1.1 65,000 41,505 PASS LCPD1000 E1.1 10,000 4,519 PASS PDUD1000 E1.1 42,000 24,430 PASS RPP02000 D-SIDE E1.1 22,000 9,595 PASS RPP04000 D-SIDE E1.1 22,000 10,428 PASS GENERATOR DISTRIBUTION GSB01000 E1.1 65,000 40,978 PASS GSB02000 E1.1 65,000 40,978. PASS REVIEINNCE WITH OR COMPLIANCE APR 17 2014 City of Tukwila BUILDING DIVISION LOAD ANALYSIS - UTILITY - INITIAL PROJECT: EDGECONNEX TUKWILA, WA PHASE 1 MISCELLANEOUS ELECTRICAL LOADS # DESCRIPTION F.L.A. VOLT. PH. kVA 1 15,570SF LIGHTING (3.5 VA/SF) - - • - 54.5 1 RECEPTACLES (1 VA/SF) - - - 15.3 1 MISCELLANEOUS - - - 53.1 1 WATER HEATER - - - 4.5 PHASE 1 MISCELLANEOUS ELECTRICAL LOADS SUBTOTAL (KVA) 127.4 PHASE 1 DATA CENTER MECHANICAL EQUIPMENT # DESCRIPTION F.L.A. VOLT. PH. kVA 2 DATA CENTER CRAGS 93.7 480 3 155.8 1 DATA CENTER CRACS (REDUNDANT, FAN ONLY) 14.0 480 3 11.6 1 UPS/ELEC ROOM CRACS 39.2 480 3 32.6 1 UPS/ELEC ROOM CRACS (REDUNDANT, FAN ONLY) 7.5 480 3 6.2 4 DATA CENTER ACCU'S 8.4 480 3 27.9 2 DATA CENTER ACCU'S (REDUNDANT) 0.0 480 3 0.0 2 DATA CENTER REFRIGERANT PUMPS 7.0 480 3 11.6 1 DATA CENTER REFRIGERANT PUMPS (REDUNDANT) 0.0 480 3 0.0 1 UPS/ELEC ROOM ACCU'S 5.6 480 3 4.7 1 UPS/ELEC ROOM ACCU'S (REDUNDANT) 0.0 480 3 0.0 2 1.6 480 3 2.7 BATTERY EF (3/4HP) 1 SSI CRAC 7.5 480 3 6.2 1 SSI ACCU 8.4 480 3 7.0 PHASE 1 DATA CENTER MECHANICAL EQUIPMENT SUBTOTAL (KVA) 266.4 PHASE 1 DATA CENTER UPS EQUIPMENT # DESCRIPTION F.L.A. VOLT. PH. kVA 1 800kW CRITICAL LOAD (0.95 pf) (80% UTILIZATION) 810.3 480 3 673.7 2 60.1 480 3 100.0 UPS BATTERY CHARGING (FULL LOAD AT 10%) PHASE 1 DATA CENTER UPS EQUIPMENT SUBTOTAL (KVA) 773.7 PHASE 1 TOTAL UTILITY LOAD (KVA) 1,167 SERVICE SIZE AT 480Y/277V, 3-PHASE, 4-WIRE (AMPS) 4,000 AMPS LOAD AT 480Y/277V, 3-PHASE, 4-WIRE (AMPS) 1,404 AMPS SPARE CAPACITY AT 480Y/277V, 3-PHASE, 4-WIRE (AMPS) 2,596 AMPS LOAD ANALYSIS - UTILITY -ULTIMATE PROJECT: EDGECONNEX TUKWILA, WA MISCELLANEOUS ELECTRICAL LOADS # DESCRIPTION F.L.A. VOLT. PH. kVA 1 15,570SF LIGHTING (3.5 VA/SF PER NEC T220.12) - - - 54.5 1 RECEPTACLES (1 VA/SF PER NEC T220.12) - - - 15.3 1 MISCELLANEOUS - - - 53.1 1 WATER HEATER - - - 4.5 PHASE 2 MISCELLANEOUS ELECTRICAL LOADS SUBTOTAL (KVA) 127.4 DATA CENTER MECHANICAL EQUIPMENT # DESCRIPTION I F.L.A. VOLT. PH. kVA 10 DATA CENTER CRAGS 102.7 480 3 853.8 2 DATA CENTER CRACS (REDUNDANT, FAN ONLY) 14.0 480 3 23.3 2 UPS/ELEC ROOM CRACS 39.2 480 3 65.2 1 UPS/ELEC ROOM CRACS (REDUNDANT, FAN ONLY) 7.0 480 3 5.8 20 DATA CENTER ACCU'S 8.4 480 3 • 139.7 4 DATA CENTER ACCU'S (REDUNDANT) 8.4 480 3 0.0 10 DATA CENTER REF. PUMPS (NON -COINCIDENTAL) 7.0 480 3 0.0 2 DATA CENTER REF. PUMPS (NON -COINCIDENTAL, REDUND. 7.0 480 3 0.0 2 UPS/ELEC ROOM ACCU'S 5.6 480 3 9.3 1 UPS/ELEC ROOM ACCU'S (REDUNDANT) 0.0 480 3 0.0 10 30KW CRA REHEAT DIVERSITY AT 60% -14.4 480 3 -120.0 1 SSI CRAC 7.5 480 3 6.2 1 SSI ACCU 8.4 480 3 7.0 PHASE 2 DATA CENTER MECHANICAL EQUIPMENT SUBTOTAL (KVA) 977.1 DATA CENTER UPS EQUIPMENT # DESCRIPTION F.L.A. VOLT. PH. kVA 1 1600kW CRITICAL LOAD (0.95 pf) (80% UTILIZATION) 1,539.6 480 3 1,280.0 4 60.1 480 3 200.0 UPS BATTERY CHARGING (4 UPS AT 10% FULL CHARGING) PHASE 2 DATA CENTER UPS EQUIPMENT SUBTOTAL (KVA) 1,480.0 TOTAL UTILITY LOAD (KVA) 2,584 LOAD AT 480Y/277V, 3-PHASE, 4-WIRE 3,109 AMPS SERVICE SIZE AT 480Y/277V, 3-PHASE, 4-WIRE 4,000 AMPS SPARE CAPACITY AT 480Y/277V, 3-PHASE, 4-WIRE 891 AMPS Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 X C --- CD G� PIZ D: EDCSEA01 W co r N ISSUES & REVISIONS No. Date Description 1 02/17/2014 ISSUE FOR PERMIT A 03/28/2014 ADDENDUM 1 RECEIVED CITY OF TUKWILA APR 1 1 2014 PERMIT CENTER SHEETTIILE ELECTRICAL SCHEDULES DRAWN: WAM REVIEWED: WAM PROJECT NO.: C1047.00 SHEET NO. E4.1 1 PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. MAIN DISTRIBUTION PANEL 'MDSA1000' DISTRIBUTION PANEL RATINGS: 480V, 30, 3W, 800A DISTRIBUTION PANEL LOADS # DESCRIPTION F.L.A. VOLT. PH. DIV. FACTOR LOAD TOTAL F.L.A. VOLT-AMPERES 1 UPSA1000 (100% LOADED) 661.5 480 3 1.25 826.9 687,464 1 60.1 480 3 1.00 60.1 49,967 UPSA1000 (BATTERY CHARGING) 1 MDPA1000 (NOTE 1) 169.6 480 3 1.00 169.6 141,005 1 TEMP FEED TO MDPC1000 (NOTE 1) 212.7 480 3 1.00 212.7 176,829 DISTRIBUTION PANEL LOAD TOTALS 1,269.3 1,055,265 NOTE 1: LOAD ONLY INCLUDE PRESENT DAY LOADS. TEMP FEED TO MDPC1000 TO BE REMOVED AND RELOCATED TO FUTURE MDSC1000 AS LOAD REQUIREMENTS INCREASE. MECHANICAL DISTRIBUTION PANEL 'MDPA1000' DISTRIBUTION PANEL RATINGS: 480V, 30, 3W, 800A DISTRIBUTION PANEL LOADS # DESCRIPTION F.L.Q. VOLT. PH. DIV. FACTOR LOAD TOTAL F.L.A. VOLT-AMPERES 1 ISS CRA UNIT 39.2 480 3 1.00 39.2 32,591 1 ISS CONDENSING UNIT 5.6 480 3 1.00 5.6 4,656 1 CRA UNITS 102.7 480 3 1.00 102.7 85,385 1 REF. PUMPS (NOTE 1) 7.0 480 3 0.00 0.0 0 1 DUAL COND. UNITS 16.8 480 3 1.00 16.8 13,968 1 25% LARGEST MOTOR (CRA COMP.) 5.3 480 3 1.00 5.3 4,406 PRESENT LOAD TOTALS 169.6 141,005 1 CRA UNITS (ALT. SOURCE) FUT. 102.7 480 3 1.00 102.7 85,385 1 REF. PUMPS (NOTE 1) (ALT. SOURCE) FUT. 7.0 480 3 0.00 0.0 0 1 DUAL COND. UNITS (ALT. SOURCE) FUT. 16.8 480 3 1.00 16.8 13,968 2 CRA UNITS FUT. 102.7 480 3 1.00 205.4 170,770 2 REF. PUMPS (NOTE 1) FUT. 7.0 480 3 0.00 0.0 0 2 DUAL COND. UNITS FUT. 16.8 480 3 1.00 33.6 27,935 FUTURE LOAD TOTALS 358.5 298,057 DISTRIBUTION PANEL LOAD TOTALS 528.1 439,062 NOTES: 1) PUMP IS NON -COINCIDENTAL WITH COMPRESSOR IN ASSOCIATED CRA UNIT. PDU DISTRIBUTION PANEL 'PDUA1000' DISTRIBUTION PANEL RATINGS: 208/120V, 30, 4W, 1200A DISTRIBUTION PANEL LOADS # DESCRIPTION F.L.A. VOLT. PH. DIV. FACTOR LOAD TOTAL F.L.A. VOLT-AMPERES 1 RPP01A01/RPPO1A02 0.4 480 3 1.00 0.4 346 1 RPPO4A01/RPPO4A02 8.3 480 3 1.00 8.3 6,928 • DISTRIBUTION PANEL LOAD TOTALS 8.8 7,275 MECHANICAL DISTRIBUTION PANEL 'MDPC1000' DISTRIBUTION PANEL RATINGS: 480V, 30, 3W, 800A DISTRIBUTION PANEL LOADS # DESCRIPTION F.L.A. VOLT. PH. DIV. FACTOR LOAD TOTAL F.L.A. VOLT-AMPERES 1 TRNC1000 (PANEL'LCPC1000') 43.1 480 3 1.00 43.1 35,823 1 ELEC RM CRA UNIT 39.2 480 3 1.00 39.2 32,591 1 ELEC RM CONDENSING UNIT 5.6 480 3 1.00 5.6 4,656 1 CRA UNITS 102.7 480 3 1.00 102.7 85,385 1 REF. PUMPS (NOTE 1) 7.0 480 3 0.00 0.0 0 1 DUAL COND. UNITS 16.8 480 3 1.00 16.8 13,968 1 25% LARGEST MOTOR (CRA COMP.) 5.3 480 3 1.00 5.3 4,406 PRESENT LOAD TOTALS 212.7 176,829 1 CRA UNITS (ALT. SOURCE) FUT. 102.7 480 3 1.00 102.7 85,385 1 REF. PUMPS (NOTE 1) (ALT. SOURCE) FUT. 7.0 480 3 0.00 0.0 0 1 DUAL COND. UNITS (ALT. SOURCE) FUT. 16.8 480 3 1.00 16.8 13,968 2 CRA UNITS FUT. 102.7 480 3 1.00 205.4 170,770 2 REF. PUMPS (NOTE 1) FUT. 7.0 480 3 0.00 0.0 0 2 DUAL COND. UNITS FUT. 16.8 480 3 1.00 33.6 27,935 FUTURE LOAD TOTALS 358.5 298,057 DISTRIBUTION PANEL LOAD TOTALS 571.2 474,885 NOTES: 1) PUMP IS NON -COINCIDENTAL WfTH COMPRESSOR IN ASSOCIATED CRA UNIT. PDU DISTRIBUTION PANEL 'PDUC1000' DISTRIBUTION PANEL RATINGS: 208/120V, 30, 4W, 1200A DISTRIBUTION PANEL LOADS # DESCRIPTION F.L.A. VOLT. PH. DIV. FACTOR LOAD TOTAL F.L.A. VOLT-AMPERES 1 RPPO2C01/RPPO2CO2 0.0 480 3 1.00 0.0 0 1 RPPO5CO3/RPPO5C04 0.0 480 3 1.00 0.0 0 • DISTRIBUTION PANEL LOAD TOTALS 0.0 0 MAIN DISTRIBUTION PANEL 'MDSB1000' DISTRIBUTION PANEL RATINGS: 480V, 30, 3W, 1600A DISTRIBUTION PANEL LOADS # DESCRIPTION F.L.A. VOLT. PH. DIV. FACTOR LOAD TOTAL F.L.A. VOLT-AMPERES 1 UPSB1000 (100% LOADED) 661.5 480 3 1.25 826.9 687,464 1 60.1 480 3 1.00 60.1 49,967 UPSB1000 (BATTERY CHARGING) 1 MDPB1000 (NOTE 1) 289.1 480 3 1.00 289.1 240,358 1 TEMP FEED TO MDPD1000 (NOTE 1) 97.0 480 3 1.00 97.0 80,679 DISTRIBUTION PANEL LOAD TOTALS 1,273.1 1,058,468 NOTE 1: LOAD ONLY INCLUDE PRESENT DAY LOADS. TEMP FEED TO MDPD1000 TO BE REMOVED AND RELOCATED TO FUTURE MDSD1000 AS LOAD REQUIREMENTS INCREASE. MECHANICAL DISTRIBUTION PANEL 'MDPB1000' DISTRIBUTION PANEL RATINGS: 480V, 30, 3W, 800A DISTRIBUTION PANEL LOADS # DESCRIPTION F.L.A. VOLT. PH. DIV. FACTOR LOAD. TOTAL F.L.A. VOLT-AMPERES 1 ELEC RM CRA UNIT FUT. 39.2 480 3 1.00 39.2 32,591 1 ELEC RM CONDENSING UNIT FUT. 5.6 480 3 1.00 5.6 4,656 1 CRA UNITS 102.7 480 3 1.00 102.7 85,385 1 REF. PUMPS (NOTE 1) 7.0 480 3 0.00 0.0 0 1 DUAL COND. UNITS 16.8 480 3 1.00 16.8 13,968 1 CRA UNITS (ALT. SOURCE) 102.7 480 3 1.00 102.7 85,385 1 REF. PUMPS (NOTE 1) (ALT. SOURCE) 7.0 480 3 0.00 0.0 0 1 DUAL COND. UNITS (ALT. SOURCE) 16.8 480 3 1.00 16.8 13,968 1 25% LARGEST MOTOR (CRA COMP.) 5.3 480 3 1.00 5.3 4,406. PRESENT LOAD TOTALS 289.1 240,358 2 CRA UNITS FUT. 102.7 480 3 1.00 205.4 170,770 2 REF. PUMPS (NOTE 1) FUT. 7.0 480 3 0.00 0.0 0 2 DUAL COND. UNITS FUT. 16.8 480 3 1.00 33.6 27,935 FUTURE LOAD TOTALS 239.0 198,705 DISTRIBUTION PANEL LOAD TOTALS 528.1 439,062 NOTES: 1) PUMP IS NON -COINCIDENTAL WITH COMPRESSOR IN ASSOCIATED CRA UNIT. PDU DISTRIBUTION PANEL 'PDUB1000' DISTRIBUTION PANEL RATINGS: 208/120V, 30, 4W, 1200A DISTRIBUTION PANEL LOADS # DESCRIPTION F.L.A. VOLT. PH. DIV. FACTOR LOAD TOTAL F.L.A. VOLT-AMPERES 1 RPPO1 B03/RPPO1 B04 0.4 480 3 1.00 0.4 346 1 RPPO5B01/RPPO5B02 0.0 480 3 1.00 0.0 0 • DISTRIBUTION PANEL LOAD TOTALS 0.4 346 MECHANICAL DISTRIBUTION PANEL 'MDPD1000' DISTRIBUTION PANEL RATINGS: 480V, 30, 3W, 800A DISTRIBUTION PANEL LOADS # DESCRIPTION F.L.A. VOLT. PH. DIV. FACTOR LOAD TOTAL F.L.A. VOLT-AMPERES 1 TRND1000 (PANEL'LCPD1000') 46.9 480 3 1.00 46.9 39,026 1 ELEC RM CRA UNIT 39.2 480 3 1.00 39.2 32,591 1 ELEC RM CONDENSING UNIT 5.6 480 3 1.00 5.6 4,656 1 25% LARGEST MOTOR (CRA COMP.) 5.3 480 3 1.00 5.3 4,406 PRESENT LOAD TOTALS 97.0 80,679 1 CRA UNITS (ALT. SOURCE) FUT. 102.7 480 3 1.00 102.7 85,385 1 REF. PUMPS (NOTE 1) (ALT. SOURCE) FUT. 7.0 480 3 0.00 0.0 0 1 DUAL COND. UNITS (ALT. SOURCE) FUT. 16.8 480 3 1.00 16.8 13,968 3 CRA UNITS FUT. 102.7 480 3 1.00 308.1 256,154 3 REF. PUMPS (NOTE 1) FUT. 7.0 480 3 0.00 0.0 0 3 DUAL COND. UNITS FUT. 16.8 480 3 1.00 50.4 41,903 FUTURE LOAD TOTALS 478.0 397,409 DISTRIBUTION PANEL LOAD TOTALS 575.0 478,088 NOTES: 1) PUMP IS NON -COINCIDENTAL WfTH COMPRESSOR IN ASSOCIATED CRA UNIT. PDU DISTRIBUTION PANEL 'PDUD1000' DISTRIBUTION PANEL RATINGS: 208/120V, 30, 4W, 800A DISTRIBUTION PANEL LOADS # DESCRIPTION F.L.A. • VOLT. PH. DIV. FACTOR LOAD TOTAL F.L.A. VOLT-AMPERES 1 RPPO2D03/RPPO2D04 0.0 480 3 1.00 0.0 0 1 RPPO4D03/RPPO4D04 8.3 480 3 1.00 8.3 6,928 • DISTRIBUTION PANEL LOAD TOTALS 8.3 6,928 4111 Ckt Load (VA) Description of Load Type Ckt Phase A Phase B Phase C Ckt Type Brkr (VA) (VA) (VA) Brkr Description of Load Load Ckt (VA) # 1 ,080 RCPT-GREEN ROOM 20/1 1,962 3 1,260 RCPT -GREEN ROOM R 20/1 5 1,400 RCPT-COFFEE MAKER K 20/1 2,050 20/1 L LIGHTING 882 2 20/1 L LIGHTING 790 4 7 1,200 RCPT - MICROWAVE K 20/1 2,167 2,042 20/1 L DATA CENTER LTG 642 6 9 500 PRE -ACTION PACKAGE- M 20/1 500 PRE -ACTION PACKAGE-1 M 20/1 ,033 20/1 L DATA CENTER LTG 967 8 20/1 L ELEC RM .LIGHTING 533 10 13 SPARE 20/1 500 20/ SPARE 12 15 900 RCPT- ELEC RM/MECH 20/1 17 720 RCPT-DC R 20/1 900 20/.1 SPARE 14 20/1 SPARE 16 19 540 RCPT - EQUIP YARD/ROOF 20/1 ,290 720 20/ SPARE 18 21 SPARE 20/1 23 SPARE 20/1 750 20/2 WH WATER HEATER WH-1 750 20 WH - 750 22 25 SPARE 20/1 4,562 4,562 60/2 H FCU02000 4,562 24 27 SPARE 40/2 29 2,160 H 4,562 26 30/3 C CON28021 2,160 28 31 2,500 GEN01000 JKT WTR HTR 40/2 4,660 2,160 C - 2,160 30 33 2,500 35 792 GEN01000 BATT CHG M 20/1 7,062 C 2,160 32 60/2 H FCU03000 4,562 34 37 SPARE 20/1 2,160 5,354 H - 4,562 36 39 SPARE 40/2 4 2,160 30/3 C CON30031 2.160 38 2,160 40 2,160 2,160 42 Subtotals: 16,801 16,115 17,497 Load Type Connected Diversified Load Load Load Type Connected Load Diversified Load (R) Receptacles 4,500 4,500 (L) Lighting 3,814 4,768 (C) Cooling 12,960 0 (EL) Exterior Lighting 0 0 (H) Heating 23246 23,246 (WH) Water Heate 1,500 1,500 (F) Fans 0 0 ( T) Largest Motor 0 0 (M) Miscellaneous 1,792 1,792 (SP) Subpanel 0 Total Connected Load: Total Diversified Load: 50,412 VA = 140 AMPS 35,806 VA 99 AMPS 9 m El 19 Ea 29 39 Volts: 208Y/120 kAIC: 10 Cu Bus: 225 MCB: 225 MLO: Load (VA) 1,000:. 1,000 1,000: 500 500 250 360 500 500 720 540 540 180:: 900 180 2,500 2,500 792 41 Description of Load ISS-01 RACK TRANSFER SEC01000 FAC01000. EPO01000 PHONE BOARD PRE -ACTION PACKAGE.-1 PRE -ACTION PACKAGE-1 RCPT- MECH RCPT - EQUIP YARD/ROOF RCPT- ELEC RM REHEAT/HUMID LOCKOUT RCPT - DC RCPT- DC CORD REEL GEN02000 JKT WTR HTR GEN02000 BATT CHG SPARE. SPARE Load Type (R) Receptacles (C) Cooling (H) Heating (F) Fans (M) Miscellaneous Panel: 3-Phase, 4-Wire Type Ckt Brkr 20/3 M 20/1 20/1 Phase.A (VA) 2,110 20/1 20/ 20/ 1,467 860 20/ 20/ 20/ 720 20/ 20 20/ 4,742. 20/ 40/2 20/1 20/1 40/2 4,660 2,160 Subtotals: Connected Load 3,240 12,960 18,246 0 10,472 16,719 Diversified Load 3240 0 18,246 0 10,472 CPD1000 Phase B (VA) 2,101 1,891 500 540 3,060 7,062 2,160. 17,314 Phase C (VA). 1,642 Ckt Brier Type 20/ 20/ 20/ 20/ 678. 20/ 20/ 20/ 500 20/1 20/1 20/ 5,102 2,340. 20/ 60/2 30/3 5,354 60/2 30/3 2,160 17,775 Load Type (L) Lighting (EL) Exterior Lighting (WH) Water Heater (MT) Largest Motor (SP) Subpanel Connected Load 5,639 0 0 0 0 Door in Door Construction: NEMA Retina: 1 Feed Thru: Surf. Mtd: X Flush Mtd: New/Exist.: NEW Description of Load LIGHTING LIGHTING DATA CENTER LTG DATA CENTER LTG WAREHOUSE LIGHTING. ELEC RM LIGHTING EXF01000 SPARE SPARE SPARE SPARE FCU01000 CON27011 FCU04000. CON31041 Diversified Load 7,049 0 0 0 0 Total Connected Load: Total. Diversified Load: 51,807 VA 144 AMPS 39,007 VA = 1.08 AMPS Load (VA) 1,110. 1,101: 642 967 1,391 428 500 4 8 10 El 20 4,562 4,562 2,160: 2,160 2,160 4,562 4,562 2,160 2,160 2,160 24 26 D 30 El 34 36 38 40 42 REVIEWED EVI�w FOR COMPLIANCE NFPA70 - NEC. APR 17 2014 City of .Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 J J J D: EDCSEA01 W 0) 1 ISSUES & REVISIONS A No. Date Description 1 02/17/2014 ISSUE FOR PERMIT A03/28/2014 ADDENDUM 1 J C SHEET TITLE ELECTRICAL SCHEDULES APR 11 2014 PERMIT CENTER DRAWN: WAM REVIEWED: RWB PROJECT NO.: C1047.00 SHEET NO. 4.2 PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. itt ELECTRICAL SYMBOLS LEGEND (ALL. SYMBOLS SHOWN ARE NOT NECESSARILY USED ON DRAWINGS) SINGLE POLE SWITCH 20A. 120/277 VOLT. (MOUNTED AT 42" AFF) 3-WAY SWITCH 20A. 120/277 VOLT. (MOUNTED AT 42" AFF) 4-WAY SWITCH 20A. 120/277 VOLT. (MOUNTED AT 42" AFF) SINGLE PHASE MANUAL MOTOR SWITCH STARTER WITH THERMAL OVERLOAD ELEMENT MOUNTED M 42"AFF, UNLESS NOTED OTHERWISE. DUPLEX RECEPTACLE 20A, 125V, 3-WIRE GROUNDING TYPE (NEMA #5-20R), MOUNTED +18" AFF TO CENTERLINE UNLESS OTHERWISE NOTED. QUAD RECEPTACLE: 20A, 125V, 3-WIRE, GROUNDING TYPE (NEMA #5-20R), UNDER A COMMON +18"UNLESS OTHERWISE NOTED. COVER PLATE MOUNTED AFF TO CENTERLINE NLE 1 SIMPLEX RECEPTACLE: 20A, 125V, 3-WIRE, GROUNDING TYPE (NEMA #5-20R), MOUNTED +18" AFF TO CENTERLINE UNLESS OTHERWISE NOTED. NEW DUPLEX OR QUAD. RECEPTACLE ON UPS PROTECTED SYSTEM: DEVICE COLOR RED: 20A, 125V, 3WIRE, GROUNDING TYPE MOUNTED 18"AFF TO. CENTERLINE UNLESS SPECIFICALLY NOTED OTHERWISE. IG DUPLEX RECEPTACLE: 20A, 125V, 3WIRE, GROUNDING TYPE (NEMA 5-20R). 'AC' INDICATES AC MOUNTED ABOVE COUNTER TOP. COORDINATE MOUNTING HEIGHT WITH COUNTER CONTRACTOR. 'IG' INDICATES ISOLATED GROUNDING TYPE. GFI GROUND FAULT CIRCUIT INTERRUPTER TYPE DUPLEX RECEPTACLE 20A, 125V, 3-WIRE GROUNDING TYPE. MOUNTED 18"AFF TO CENTERLINE, UNLESS NOTED OTHERWISE. )WP GROUND FAULT CIRCUIT INTERRUPTER TYPE DUPLEX RECEPTACLE MOUNTED IN A WEATHERPROOF DEVICE BOX, 20A, 125V, 3-WIRE GROUNDING TYPE. COORDINATE MOUNTING WITH INSTALLATION LOCATION. -111111 a �L 27kV LA 2'x4' FLUORESCENT FIXTURE 1'x4' FLUORESCENT FIXTURE 2'x2' FLUORESCENT FIXTURE EMERGENCY LIGHT FIXTURE. (1) LAMP UNSWITCHED AND WIRED TO EMERGENCY SOURCE: REMAINING LAMPS SWITCHED AND WIRED TO NORMAL SOURCE. EMERGENCY WALL MOUNTED LIGHT FIXTURE. ALL LAMPS WIRED TO NORMAL AND EMERGENCY SOURCE. WALL MOUNTED LIGHT FIXTURE Q RECESSED DOWN LIGHT OR INCANDESCENT LIGHT FIXTURE. RECESSED WALL WASHER = SURFACE MOUNTED BRACKET LIGHT 8 EXIT LIGHT FIXTURE.. COORDINATE EXACT LOCATION MOUNTING AND FACE COLOR WITH AUTHORITY HAVING JURISDICTION. PROVIDE ARROWS AS INDICATED ON PLAN. SHADED AREAS INDICATE REQUIRED FACES. POLE MOUNTED SITE LIGHTING FIXTURE TRANSFER SWITCH. SWITCH POSITION INDICATES NORMAL POWER SOURCE. 'ATS' DESIGNATION DENOTES AUTOMATIC TRANSFER SWITCH. 0 SINGLE PHASE OR THREE PHASE MOTOR WITH INDICATED HORSEPOWER ❑I NON -FUSED, HEAVY DUTY SAFETY SWITCH COMBINATION MAGNETIC MOTOR STARTER/DISCONNECT SWITCH FUSED, HEAVY DUTY SAFETY SWITCH MOTOR STARTER, TYPE AS INDICATED ON DRAWINGS 120/208 OR 277/480 VOLT PANEL BOARD UNLESS NOTED OTHERWISE. SURFACE MOUNTED. TOP OF PANEL 72"AFF. 120/208 OR 277/480 VOLT PANEL BOARD FLUSH MOUNTED TOP OF PANEL 72"AFF. DRY TYPE TRANSFORMER. SEE ONE LINE DIAGRAM AND SPECIFICATIONS FOR TRANSFORMER INFORMATION. •ll FIXED MOUNTED CIRCUIT BREAKER. SEE ONE-UNE DIAGRAM AND SPECIFICATION S FOR MORE •J INFORMATION. (A-XXX) GAP GROUND FAULT DETECTION/ALARM. GROUND FAULT INTERRUPTION. BLOWN FUSE TRIP (SINGLE -PHASING PROTECTION) LIGHTNING ARRESTOR WITH INDICATED VOLTAGE KIRK -KEY DESIGNATION AS SHOWN ON ONE-UNE DIAGRAM. '#' INDICATES KIRK -KEY LABEL IN SYSTEM. ONE -LINE DIAGRAM FEEDER/CIRCUIT CONTINUATION SYMBOL. WHERE SHOWN ON ONE -LINE DIAGRAM, FEEDER/CIRCUIT SCHEDULE DESIGNATION. REFER TO FEEDER SCHEDULES FOR SIZE. GENERATOR ANNUNCIATOR PANEL ELECTRICAL SYMBOLS LEGEND MoNrI)) - CONDUIT CONCEALED IN OR BELOW FLOOR GRADE CONDUIT IN CEILING OR WALLS SWITCH LEGS HOT Z / I HASH MARKS INDICATE NUMBER OF #12 CONDUCTORS IN CONDUIT (UNLESS NOTED OTHERWISE ON PLANS OR ONE LINE DIAGRAM) GROUND NEUTRAL Z�I SINGLE HOMERUN TO PANEL WITH CIRCUIT NUMBER AS INDICATED WHERE SINGLE HOMERUNS ARE SHOWN NEUTRAL AND GROUND CONDUCTORS SHALL NOT BE SHARED WITH OTHER CIRCUITS. MULTIPLE HOMERUNS TO PANEL WITH CIRCUIT NUMBERS AS INDICATED Z I CONDUIT EXPOSED 0 CONDUIT UP 0 CONDUIT DOWN C OSD ) OCCUPANCY SENSOR SWITCHING DEVICE. cos#) EPO HH REFER TO SPECIFICATIONS. OCCUPANCY SENSOR. '#' DENOTES TYPE OF SENSOR. REFER TO SPECIFICATIONS. ARROW(S) INDICATE SENSOR ORIENTATION. EPO SYSTEM PUSHBUTTON. CHEMICAL GROUND ROD GROUND ROD GROUNDING HANDHOLE OPEN OFFICE FURNITURE POWER POLE SUPPLIED WITH FURNITURE. OPEN OFFICE FURNITURE COMMUNICATIONS POLE SUPPLIED WITH FURNITURE. LIQUIDTIGHT FLEXIBLE METAL CONDUIT (LFMC) CONNECTION TO EQUIPMENT. MAXIMUM LENGTH OF FLEXIBLE CONDUIT 6'-0". . 4" SQUARE JUNCTION BOX RECESSED IN WALL UNLESS NOTED OTHERWISE. 1-1 4" 12/6 JUNCTION BOX WITH CONDUIT FOR VOICE/DATA CABLING STUBBED TO ABOVE CEILING, SIZE AS D INDICATED. , PROVIDE BUSHING AT CONDUIT END ABOVE CEILING. NUMBERS ADJACENT TO DEVICE INDICATE QUANTITY OF VOICE AND DATA RECEPTACLES (LE. - '12/6' = (12) DATA AND (6) VOICE). A ABV AC AFC AFF AFC AHU ARF AUX. AWG BRF BC BLDG ELECTRICAL ABBREVIATIONS AMPS ABOVE ABOVE COUNTER AVAILABLE FAULT CURRENT ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDLING UNIT ABOVE RAISED FLOOR AUXILIARY AMERICAN WIRE GAUGE BELOW RAISED FLOOR BELOW COUNTER BUILDING C C.F.C.I. CH CKT CL CLG COMP CONC COND CONN CT CTV CTW CONDUIT CONTRACTOR FURNISHED, CONTRACTOR INSTALLED CHILLER CIRCUIT CENTERLINE CEILING COMPRESSOR CONCRETE CONDENSER CONNECTION CURRENT TRANSFORMER CABLE TELEVISION COOLING TOWER DISC. DS DN DTS DWG DISCONNECT DISCONNECT SWITCH DOWN DOUBLE -THROW SWITCH DRAWING (E) EA. EC EDF EF ELEC. ELEV. EMT ENL. E.O. EPO EXH. EXIST. EXISTING EACH ELECTRICAL CONTRACTOR ELECTRIC DRINKING FOUNTAIN EXHAUST FAN ELECTRICAL ELEVATOR ELECTRICAL METALLIC TUBING ENLARGED ELECTRICALLY OPERATED EMERGENCY POWER OFF EXHAUST EXISTING FCU FLA FLEX. FLR FMS FS FT FUT. FAN COIL UNIT FULL LOAD AMPS FLEXIBLE FLOOR FACILITY MONITORING SYSTEM FUSED SWITCH FOOT/FEET FUTURE GC GFI GND GNDG GEN. GENERAL CONTRACTOR GROUND FAULT INTERRUPTOR GROUND GROUNDING GENERATOR HP HORSE POWER IC INTERMEDIATE CLASS J-BOX JUNCTION BOX KVA KILOVOLT -AMPS KW KILOWATTS LA LFMC LRGST LRA LTG LVL MAX MC MECH MIN MSGB M.O. MTR MV LIGHTNING ARRESTOR LIQUIDTIGHT FLEXIBLE METAL CONDUIT LARGEST LOCKED ROTOR AMPS LIGHTING LEVEL MAXIMUM MECHANICAL CONTRACTOR MECHANICAL MINIMUM MASTER STATION GROUND BAR MOTOR OPERATED MOTOR MEDIUM VOLTAGE N.C. NEC NEMA NFPA NF. N.O. NIC NTS NORMALLY CLOSED NATIONAL ELECTRIC CODE NATIONAL ELECTRICAL MANUF. ASSOC. NATIONAL FIRE PROTECTION ASSOCIATION NON -FUSED NORMALLY OPEN NOT IN CONTRACT NOT TO SCALE OAHU OUTSIDE AIR HANDLING UNIT O.C. ON CENTER O.F.C.I. OWNER FURNISHED, CONTRACTOR INSTALLED OHE OVERHEAD ELECTRIC PH PL PROV'S. PVC PWR PHASE PILOT LIGHT PROVISIONS POLYVINYL CHLORIDE CONDUIT POWER RCPT REDUND. RE: REQ'D REV RLA RM RPM RECEPTACLE REDUNDANT REFERENCE REQUIRED REVISION RUNNING LOAD AMPS ROOM REVOLUTIONS PER MINUTE S.T. STD SW SWBD SWGR SHUNT TRIP STANDARD SWITCH SWITCHBOARD SWITCHGEAR TRANS. 1V TYP TRANSITION TELEVISION TYPICAL UGE U.N.O. UTIL UNDERGROUND ELECTRIC UNLESS NOTED OTHERWISE UTILITY COMPANY V VA VAV VOLTS VOLT AMPS VARIABLE AIR VOLUME W WH W/ W/O WP XFMR Z WATTS WATER HEATER WITH WITHOUT WEATHERPROOF TRANSFORMER IMPEDANCE GENERAL ELECTRICAL NOTES CODES AND STANDARDS ALL ELECTRICAL WORK PREFORMED UNDER THIS CONTRACT SHALL COMPLY WITH THE 2008 VERSION OF THE NATIONAL ELECTRICAL CODE (INCLUDING ANY CITY OF. ENGELWOOD AND DOUGLAS COUNTY AMENDMENTS), NFPA 70, ADA (AMERICAN DISABILITIES ACT) AND ALL LOCAL CODES AND ORDINANCES. PLRASFS THE WORD "PROVIDE" AS USED IN THESE DRAWINGS SHALL MEAN "MATERIALS AND LABOR FURNISHED AND INSTALLED BY CONTRACTOR". THE PHRASE "OWNER PROVIDED/CONTRACTOR RECEIVED AND INSTALLED" AS USED IN THESE DRAWINGS SHALL MEAN EQUIPMENT IS PURCHASED AND SHIPPED BY THE OWNER AND IT IS THE CONTRACTOR'S RESPONSIBILITY TO RECEIVE/OFFLOAD THE EQUIPMENT AND TO STORE THE EQUIPMENT IN A MANNER WHICH PROTECTS THE EQUIPMENT FROM ENVIRONMENTAL AND PHYSICAL HAZARDS. GENERAL SECURE AND PAY ALL NECESSARY PERMITS AND FEES WHERE REQUIRED FOR EXECUTION AND COMPLETION OF WORK AND INCLUDE IN COST OF BID. ALL EQUIPMENT SHALL BE NEW AND UNDERWRITERS LABORATORIES (U.L.) LISTED. ALL NEW EQUIPMENT AND DEVICES SHALL BE OF THE SAME MANUFACTURER AND QUALITY AS THE BASE BUILDING EQUIPMENT AND DEVICES UNLESS NOTED OTHERWISE. DETERMINE THE ARC FLASH HAZARD RATING FOR EACH NEW SWITCHBOARD, PANELBOARD, INDUSTRIAL CONTROL PANEL AND MOTOR CONTROL CENTER AND PROVIDE THE PROPER LABELING AS REQUIRED PER NEC ART.' 110.16. PER ORDINANCE 2011.33 ALL EQUIPMENT RATED AT 1,000AMPS OR GREATER INSTALLED BY CONTRACTOR SHALL BE TESTED IN CONFORMANCE WITH UL STANDARD 869 OR 891 FOR INSULATION BREAKDOWN PRIOR TO ITS BEING ENERGIZED. THIS TEST SHALL BE PERFORMED BY AN INDEPENDENT TESTING FACILITY OR AGENCY APPROVED BY THE AUTHORITY HAVING JURISDICTION. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH BUILDING OWNER AND BCEI REQUIREMENTS. WHERE A SHUTDOWN OF THE ELECTRICAL SYSTEM OR ANY OTHER SYSTEM IS REQUIRED THE SHUTDOWN WILL BE COORDINATED WITH AND APPROVED BY THE OWNER AND BCEI AT LEAST TWO WEEKS PRIOR TO THE SHUTDOWN. INFORMATION PROVIDED SHALL INCLUDE BEGINNING DATE AND TIME, THE DURATION AND THE AREA AND SYSTEMS AFFECTED_ PROVIDE CONNECTIONS TO EQUIPMENT FURNISHED BY OTHERS AS SHOWN ON DRAWINGS. COORDINATE WITH OTHER TRADES FOR INSTALLATION. CONTRACTOR SHALL BE REQUIRED TO KEEP THE WORK INSTALLED BY HIM IN REPAIR AND PERFECT WORKING ORDER FOR ONE (1) YEAR FROM TIME OF COMPLETION AND FINAL ACCEPTANCE. THE CONTRACTOR SHALL CAREFULLY EXAMINE THE SITE AND SHALL THOROUGHLY FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS WITHIN THE SCOPE OF WORK. BY THE ACT OF SUBMITTING A BID, THE CONTRACTOR WILL BE DEEMED TO HAVE MADE SUCH EXAMINATION AND TO HAVE ACCEPTED SUCH CONDITIONS, AND TO HAVE MADE ALLOWANCE THEREFORE IN PREPARING HIS BID. THE CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE WITH ALL TRADES ANY ELECTRICAL REFERENCES ON DRAWINGS. VERIFY LOCATIONS OF ALL ELECTRICAL EQUIPMENT WITH DRAWINGS AND INTERIOR DETAILS AND . FINISHES, IN CENTERING OUTLETS AND LOCATING BOXES AND OUTLETS, ALLOW FOR OVERHEAD PIPES, DUCT& TRIM, PANELING, HUNG CEILINGS, AND THE LIKE AND CORRECT ANY INACCURACY RESULTING FROM FAILURE TO DO SO WITHOUT EXPENSE TO THE OWNER. THE CONTRACTOR SHALL RELOCATE NEW EQUIPMENT FIVE FEET IN ANY DIRECTION WHERE REQUIRED WITHOUT ANY ADDITIONAL EXPENSE. ON A DAILY BASIS AND AFTER COMPLETION OF WORK CLEAN UP THE RESULTANT DEBRIS FROM THIS WORK AND REMOVE FROM THE SITE. ALL WORK PERFORMED IN AN OPERATIONAL DATA CENTER SHALL BE DONE IN A MANNER TO PREVENT THE PRODUCTION OF DUST. SUBMITTALS MANUFACTURER'S CATALOG CUTS AND SHOP DRAWINGS FOR THE FOLLOWING APPARATUS, GIVING FULL DESCRIPTION AND OTHER PERTINENT FACTS, SHALL BE SUBMITTED TO BCEI AND THEIR REVIEW SECURED BEFORE APPARATUS IN QUESTION IS ORDERED, BUILT, OR INSTALLED. (1)LIGHTING FIXTURES (2)DISTRIBUTION EQUIPMENT (3)FIRE ALARM EQUIPMENT (4)DEVICES (5)OTHER EQUIPMENT REQUESTED CONTRACTOR SHALL SUBMIT "AS -BUILT" DRAWINGS AT COMPLETION OF THE PROJECT. DRAWINGS SHALL BE SUBMITTED IN THE LATEST VERSION OF AUTOCAD FORMAT AND REPRODUCIBLE VELLUM. QUANTITIES AND TYPES OF SUBMITTALS SHALL BE AS REQUESTED. UTILITY COMPANY ARRANGE WITH THE LOCAL UTILITY COMPANY FOR NEW SERVICE AND COMPLY WITH THEIR REQUIREMENTS. PROVIDE ALL WORK NOT SHOWN OR SPECIFIED WHICH THE UTILITY COMPANY MAY DEEM NECESSARY TO FULFILL THEIR REQUIREMENTS. UTILITY COMPANY APPROVAL OF WORK SHALL BE OBTAINED. FIRE SAFING ALL PENETRATIONS IN FLOORS, WALLS AND CEIUNGS SHALL BE ADEQUATELY CLOSED UP AND FIRE SAFED PER "ASTM" E814 (U.L. 1479) AND ALL LOCAL AND STATE CODES. FIRE SAFING MATERIAL SHALL BE LISTED IN THE MOST RECENT FACTORY MUTUAL RESEARCH CORPORATION (FMRC) APPROVAL GUIDE. FIRE SAFING MATERIALS SHALL BE INSTALLED PER THE MANUFACTURER'S PUBLISHED DIRECTIVES AND SUITABLE FOR THE TYPE. OF PENETRATING MATERIAL, AND RATING OF THE PARTITION. ELECTRICAL DRAWINGS THE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF DOORS, WALLS, FURNITURE, EQUIPMENT, DUCTWORK, PIPING, ETC.. THE LOCATION OF RACEWAY SYSTEM COMPONENTS IS SCHEMATIC. THE EXACT LOCATION OF RACEWAY SYSTEM COMPONENTS SHALL BE DETERMINED BY THE CONTRACTOR IN THE HELD. INTERPRETATION OF DOCUMENTS CAREFULLY COMPARE THE DRAWINGS AND SPECIFICATIONS, CHECKING THE REQUIREMENTS AND CONDITIONS UNDER WHICH THIS INSTALLATION IS TO BE MADE. FOR CLARIFICATION BETWEEN THE VARIOUS DRAWINGS, BETWEEN DRAWINGS AND SPECIFICATIONS, OR BETWEEN SECTIONS OF THE SPECIFICATIONS, THE MATTER SHALL BE REFERRED TO BCEI BEFORE ANY WORK IS EXECUTED. THE CONTRACTOR SHALL STATE TO MAKE THIS A COMPLETE, READY TO USE INSTALLATION. IF NOT STATED IN THE PROPOSAL, IT WILL NOT BE CONSIDERED EXTRA. MISCELLANEOUS SUPPORTING MEMBERS ALL ANGLES, CHANNELS AND OTHER MISCELLANEOUS STEEL, BOLTS, ROD, ETC.. REQUIRED TO SUPPORT LIGHT FIXTURES, LADDER TRAY, OR OTHER ELECTRICAL EQUIPMENT OR DEVICES SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR. ELECTRICAL. CONNECTIONS PROVIDE FINAL ELECTRICAL CONNECTIONS FOR ALL EQUIPMENT FURNISHED UNDER OTHER DIVISIONS. TERMINATIONS ALL LUGS SHALL BE 2-BOLT, LONG BARREL TYPE WITH INSPECTION HOLES PRODUCED WITH NON -FLASHING TYPE DYES AS MANUFACTURED BY "THOMAS AND BETTS" OR APPROVED EQUAL, MINIMUM 10 TONS OF COMPRESSION. INSTALL WITH NO DAMAGE TO THE LUG, CONDUCTOR OR INSULATION. PROVIDE LUGS FOR ALL CONNECTIONS TO SWITCHBOARDS, UPS'S, TRANSFER SWITCHES, DISTRIBUTION AND LIGHTING CLASS PANELBOARDS, TRANSFORMERS, ETC. THE USE OF MECHANICAL LUGS IS PROHIBITED. CABLING/CONDUCTORS UNLESS SPECIFICALLY NOTED OTHERWISE ALL CABLING SHALL BE 2-#12, 1-#12G, 3/4"EMT. WHERE ONLY TICK MARKS ARE INDICATED WITHOUT WIRE SIZES, ALL CABLES ARE #12. ALL #8 AWG WIRE AND LARGER SHALL BE STRANDED. ALL #10 AWG WIRE AND SMALLER SHALL BE SOLID. WIRE AND CABLE SHALL BE COPPER, TYPE THHN/THWN 600VOLT INSULATION, SIZES AS INDICATED ON DRAWINGS, AND SHALL NOT BE LESS THAN #12 AWG. COLOR CODING FOR WIRE AND CABLE SHALL BE AS FOLLOWS: 120/208V-BLACK, RED, BLUE, WHITE, FOR PHASES A, B, C, AND NEUTRAL, RESPECTIVELY. 480/277V-BROWN, ORANGE, YELLOW, GRAY, FOR PHASES A, B, C, AND NEUTRAL, RESPECTIVELY. WHERE THIS COLOR CODING DIFFERS FROM THAT REQUIRED BY THE LOCAL AUTHORITY, COMPLY WITH THE LOCAL AUTHORITY. ALL WIRE AND CABLE #16AWG AND LARGER SHALL HAVE COLOR CODED INSULATION. COLOR CODING, ONCE SELECTED, MUST BE USED CONSISTENTLY FOR THE ENTIRE PROJECT. PROVIDE IDENTIFICATION BY CIRCUIT NUMBERS IN ALL CABINETS, BOXES, WIRING TROUGHS, OTHER ENCLOSURES, AT ALL SPLICES, TERMINATION POINTS, ETC. LIMIT BRANCH CIRCUIT HOMERUNS TO A MAXIMUM OF THREE PHASE CONDUCTORS (ON DIFFERENT PHASES), INSTALL THREE INDIVIDUAL NEUTRAL CONDUCTORS (FOR EACH 120V OR 277V BRANCH CIRCUIT), AND GROUND CONDUCTOR(S) IN CONDUIT. "SHARED" NEUTRALS WILL NOT BE ALLOWED. CONDUCTORS OF DIFFERENT SYSTEMS (UPS, STANDBY POWER, NORMAL POWER) SHALL NOT SHARE RACEWAYS. VOLTAGE DROP 20AMP BRANCH CIRCUITRY SHALL BE AS INDICATED BELOW: A. 120/208 VOLT CABLING SHALL BE: B. 277/480 VOLT CABLING SHALL BE: 0' - 100' #12AWG 0' - 150' #12AWG 100' - 200' # 10AWG 150' - 250' #10AWG 200' - 250' #8AWG 250' - 300' #8AWG GROUNDING GROUND ALL CONDUITS, CABINETS, MOTORS, PANELS, AND OTHER EXPOSED NON -CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH ALL PROVISIONS OF THE NATIONAL ELECTRICAL CODE OR LOCAL CODE THAT MAY APPLY. PROVIDE GROUND WIRE FOR ALL BRANCH CIRCUITING AND FEEDERS, MINIMUM #12 AWG. RACEWAYS WILL NOT BE ALLOWED TO BE THE SOLE GROUNDING PATH FOR ANY SYSTEM. HOUSEKEEPING PADS FLOOR -MOUNTED TRANSFORMERS, SWITCHBOARDS, MCC'S, UPS'S, BATTERIES, ETC. SHALL BE PLACED ON 3-1/2" HOUSEKEEPING PADS. #4 RODS SHALL BE CAST INTO FLOOR OR DRILLED TO TIE THE PAD TO FLOOR. SEE ARCHITECTURAL DRAWINGS. FLOOR -MOUNTED TRANSFORMERS ALL TRANSFORMERS SHALL BE SECURED TO THE HOUSEKEEPING PAD. THE PAD SHALL BE DRILLED TO ACCEPT EPDXY ANCHORS. THE USE OF HILTI TYPE EXPANSION ANCHORS IS PROHIBITED. VIBRATION ISOLATORS OR NEOPRENE GASKETS SHALL BE USED. SWITCHGEAR / MCC'S ALL SWITCHGEAR AND MCC INDIVIDUAL SECTIONS SHALL BE SECURED TO THE HOUSEKEEPING PAD WITH 4 EPDXY ANCHORS. ADDITIONALLY, EACH SECTION SPLIT OF GEAR SHALL BE SECURED BY BOLTS TO THE ADJACENT SECTION OF GEAR. ALL ANCHORS SHALL BE DRILLED INTO THE SLAB. VIBRATION ISOLATORS OR NEOPRENE GASKETS SHALL NOT BE USED. WALL -MOUNTED PANELBOARDS ALL WALL -MOUNTED PANELBOARDS SHALL BE SECURELY BOLTED TO WALLS BY A MINIMUM OF (4) BOLTS. ADEQUATE BLOCKING IN WALLS SHALL BE PROVIDED FOR PROPER SUPPORT OF PANELBOARDS, SHEETROCK SHALL NOT BE USED FOR SUPPORTS. CONDUIT RUNS CONDUIT RUN ON THE INTERIOR OF THE BUILDING SHALL BE EMT. CONDUIT RUN ON THE EXTERIOR SHALL BE IMC OR GRS. CONDUIT RUN UNDERGROUND SHALL BE SCHEDULE 40 PVC WITH PVC COATED GRS ELBOWS AND BENDS. PROVIDE "RED" CONCRETE ENCASEMENT WHERE CONCRETE ENCASEMENT IS INDICATED. MINIMUM SIZE CONDUIT 3/4", UNLESS OTHERWISE NOTED. TYPE MC CABLE WITH A MINIMUM #12AWG GROUND WILL BE ALLOWED FOR FIXTURE WHIPS ONLY, MAXIMUM 6'-0" LENGTH. TYPE AC CABLE WILL NOT BE ALLOWED. LIQUID TIGHT FLEXIBLE METAL CONDUIT (MIN. 18" LENGTH) SHALL BE USED FOR CONNECTIONS TO VIBRATING EQUIPMENT (MOTORS, TRANSFORMERS, ETC.). DO NOT TERMINATE IN OR FASTEN RACEWAYS TO MOTOR FOUNDATION. STEEL COMPRESSION CONNECTORS AND COUPLINGS SHALL BE USED FOR ALL EMT CONNECTIONS. FIRE ALARM, SMOKE DETECTION, FACILITY MONITORING, SECURITY AND OTHER SYSTEMS SHALL BE INSTALLED IN CONDUIT. OPEN WIRING OF ANY TYPE WILL NOT BE ALLOWED. NO RACEWAY SHALL BE WITHIN THREE INCHES (3") OF HOT WATER PIPES, OR APPLIANCES. RUN ALL RACEWAYS PARALLEL AND/OR PERPENDICULAR TO BUILDING WALLS, AVOID MOISTURE TRAPS. ROUTE CONDUITS AS CLOSE TO STRUCTURAL ROOF AS PRACTICAL. PROVIDE CONDUIT SEALS WHERE CONDUITS CROSS AREAS OF TEMPERATURE DIFFERENCES TO PREVENT CONDENSATION. PROVIDE WATERPROOF SLEEVES, AS APPROVED FOR ROOF, FLOOR AND WALL PENETRATIONS. PROVIDE SEPARATE PULL/JUNCTION BOXES AND RACEWAYS FOR EACH FEEDER AND BRANCH CIRCUIT UNLESS SPECIFICALLY APPROVED BY BCEI. PULL/JUNCTION BOXES SHALL NOT BE SHARED. PULL/JUNCTION BOXES WITH SPACE DIVIDERS WILL NOT BE ALLOWED. FIRE ALARM FIRE ALARM DRAWINGS NOT INCLUDED IN THIS SET AND ARE CONSIDERED A DEFERRED SUBMITTAL. FIRE ALARM CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARATION AND SUBMITTAL OF ALL DRAWINGS RELATED TO THE FIRE ALARM SYSTEM TO THE AUTHORITY HAVING JURISDICTION. CONTRACTOR SHALL COORDINATE WITH FIRE ALARM CONTRACTOR AND RELATED DRAWINGS AND PROVIDE ROUGH -IN AS/IF REQUIRED. SECURITY SECURITY DRAWINGS NOT INCLUDED IN THIS SET AND ARE CONSIDERED A DEFERRED SUBMITTAL SECURITY CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARATION AND. SUBMITTAL (IF REQUIRED) OF ALL DRAWINGS RELATED TO THE SECURITY SYSTEM TO THE AUTHORITY HAVING JURISDICTION. CONTRACTOR SHALL COORDINATE WITH SECURITY CONTRACTOR AND RELATED DRAWINGS AND PROVIDE ROUGH -IN AS/IF REQUIRED. DATA/VOICE/FIBER/BAS SHALL BE RESPONSIBLE SUBMITTAL DATA VOICE FIBER BAS CONTRACTOR IN S AND ARE CONSIDERED A DEFERREDMI FI B S DRAWINGS NOT INCLUDED.THISET DATA OICE BER A 1 / / N / / V01 HAVING JURISDICTION. SDICTION. FOR PREPARATION AND - SUBMITTAL (IF REQUIRED) OF ALL DRAWINGS RELATED TO THE DATA/VOICE/FIBER/BAS /BAS SYSTEM TO THE AUTHORITY CONTRACTOR SHALL COORDINATE WITH DATA/VOICE/FIBER CONTRACTOR AND RELATED DRAWINGS AND PROVIDE ROUGH -IN AS/IF REQUIRED. DEVICES ALL DEVICES SHALL BE RECESSED IN WALL WHEREVER POSSIBLE CONDUIT SHALL BE CONCEALED IN WALL TO 10' AFF MINIMUM OR ABOVE FINISHED CEILING. DEVICES INCLUDE BUT NOT LIMITED TO RECEPTACLES, LIGHT SWITCHES JUNCTION BOX ROUGH -IN FOR SECURITY, DATA VOICE, FIRE ALARM. PANELBOARD DIRECTORIES PROVIDE UPDATED, TYPED PANELBOARD DIRECTORIES. PROVIDE PHENOLIC LABELING ON ALL CFCI AND OFCI ELECTRICAL AND MECHANICAL EQUIPMENT. BREAKER TESTING E.C. RESPONSIBLE FOR HIRING INDEPENDENT 3RD PARTY TESTING AGENCY TO TEST ALL NEW, RELOCATED AND RE -ASSIGNED BREAKERS, 250A AND LARGER IN EXISTING, O.F.C.L AND C.F:C.I. EQUIPMENT. PERFORM EACH VISUAL AND MECHANICAL INSPECTION AND ELECTRICAL TEST INDICATED IN NETA ATS, SECTION 7.6 FOR MOLDED -CASE CIRCUIT BREAKERS (PRIMARY INJECTION). CERTIFY COMPLIANCE WITH TEST PARAMETERS AND SUBMIT TEST RESULTS TO BCEI FOR INLCUSION IN COMMISSIONING DOCUMENTATION. TESTING TO BE PERFORMED IN A TIMELY MANNER SO AS NOT TO INHIBIT THE PROGRESS OF THE PROJECT: SEPARATE PERMIT REQUIRED FOR: Mechanical ❑ Electrical IiPlumbing 6dgas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall b made tootscope of work without prior approval Tukwila Building Division. NOTE Revisions will require a new plan sum and may include additional plan review fees. ELECTRICAL SHEET INDEX: E0.1 ELECTRICAL SYMBOLS, NOTES & ABBREVIATIONS E0.2 ELECTRICAL SPECIFICATIONS E0.3 ELECTRICAL SPECIFICATIONS E1.1 ELECTRICAL ONE —LINE DIAGRAM E1.2 ELECTRICAL GROUNDING ONE —LINE DIAGRAM E2.D E2.0 E2.1 E2.2 E2.3 E2.4 E2.5 E3.1 E3.2 E3.3 E3.4 E3.5 ELECTRICAL DEMOLITION PLAN ELECTRICAL SITE PLAN ELECTRICAL POWER PLAN ELECTRICAL LIGHTING PLAN ELECTRICAL GROUNDING PLAN ELECTRICAL CONDUIT PLAN ELECTRICAL ROOF PLAN ELECTRICAL DETAILS ELECTRICAL DETAILS ELECTRICAL DETAILS ELECTRICAL DETAILS ELECTRICAL DETAILS E4.1 ELECTRICAL SCHEDULES E4.2 ELECTRICAL SCHEDULES E4.3 ELECTRICAL SCHEDULES E4.4 ELECTRICAL SCHEDULES FILE COPY Permit No. ELT ` 01115 Plan review approval is subject to errors and omissions. L l of construction documents does not authorize Lon of any adopted code or ordinance. Receipt roved Field Copy and conditions is acknowledged: By Date: City Of Tukwila BUILDING DIVISION ALL EQUIPMENT WILL BE IDENTIFIED, LABELED, LISTED, APPROVED AND INSTALLED BY DEFINITION OF THE 2008 NEC REVIEWED FOR COMPLIANCE WITH NFPA 70-NEC MAR 14 2014 2S City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 0 2014 PERMIT CENTER • 10400 Rodgers Road HOUSTON, TEXAS 77070 Ph: 281-374-8644 Fax: 281-374-8992 Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 LLI ISSUES & REVISIONS No. Date Description 1 02/17/2014 ISSUE FOR PERMIT SHEET WILE ELECTRICAL SYMBOLS, NOTES & ABBREVIATIONS DRAWN: WAM REVIEWED: RWB PROJECT NO.: C1047.00 SHEET NO. EO.1 PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. J ELECTRICAL SPECIFICATIONS PART I: GENERAL - ELECTRICAL 1-1 DESCRIPTION: All work on these drawings shall be done in strict accordance with these specifications. All work fairly implied as essential to the complete functioning of the electrical systems shown on the Drawings and Specifications shall be completed as part of the work of this Division unless specifically stated otherwise. It is the intention of the Drawings and Specifications to establish the types of the systems, but not set fortheach itemto. the functioningof the system. In case of ac Y doubt as to the work intended, or in the event of amplification of clarification thereof, the Contractor shall call upon BCEI for supplementary instructions, Drawings, etc. 1-2 WARRANTY: The undertaking of the work described in this Division: shall be considered equivalent to the issuance, as part of this work, of a specific guarantee extending one year beyond the date of completion ofwork and acceptance by Owner, against defects in materials and workmanship. Materials, appliances and labor necessary to effect repairs and replacementso as to maintain said work in good functioning order shall be provided as required. Replacements necessitated by normal wear in use or by Owner's abuse are not included under this guarantee. 1-3 PROJECT CONDITIONS: Visit the site of the proposed construction in order to fully understand the facilities, difficulties and restriction attending the execution of the work. No additional compensation will be allowed this Contractor for work or items omitted from his original Proposal due to his failure to inform himself regarding such matters affecting the performance of the work in this Contract or necessary forthe installation and completion of the work included herein. 1-4 PERMITS AND FEES: The contractor shall arrange and pay for all permits, fees, tests, and all inspections as required by governmental authorities. 1-5 COORDINATION WITH FIELD CONDITIONS: Contractor shall review all pertinent Drawings and adjust his work to all conditions shown there on. Discrepancies between Plans, Specifications, and actual field conditions shall be brought to the prompt attention of BCEI: Approximate location of transformers, feeders, branch circuits, lighting and power outlets panels, outlets for special systems, etc., are indicated on the Drawings. However, the Drawings, do not give complete and accurate detailed locations of suchoutlets, conduit runs, etc., and exact locations must be determined by actual field measurement. Such locations will, at all times, be subject to the approval of BCEI. Communicate with BCEI and secure approval of any outlet (light fixture, receptacle, switch, etc.) location about which there may be the least question. Outlets obviously placed . in a location not suitable to the finished room or without specific approval, shall be removed and relocated when so directed by BCEI. Location of light fixtures shall be coordinated with reflected ceiling plans. 1-6 SUBMITTALS: Contractor shall provide six sets of submittals, shop drawings, descriptive literature, physical data and a specification critique for the following items: Lighting and Distribution Class Panelboards Substations Enclosed Bus Assemblies Switchboards Heavy Duty Disconnect Switches Lighting. Fixtures and Lamps Dry Type Transformers Fire Alarm System Transient Voltage Suppression Any deviations from the specified items shall be listed on the cover sheet andclearly itemized for all deviations. The contractor shall provide two copies of owner's manuals to the architect upon completion of the work. 1-7 SUBSTITUTIONS A. The names, manufacturers, and model numbers have been used in the Contract documents to establish types of equipment and standards of quality. Where more than one manufacturer is named for a specific item of equipment, only one of the specified manufacturers will be considered for approval. Where only one manufacturer is mentioned with the phrase "or approved equal , Contractor may submit an alternate manufacturer for consideration, provided the following conditions are met: 1. Submit alternate equipment with complete descriptive data in shop drawing form. Provide sample of equipment upon request for review by Architect. Samples will be . returned if requested in writing. 2. Alternate equipment must be equal from the standpoint of materials, construction and performance. B. The Architect and Engineer shall be the sole judge of quality and equivalence of equipment, materials and methods. 1-8 QUALITY ASSURANCE: All work shall be performed in accordance with all state, local & federal codes and all authorities having jurisdiction, including but not limited to: National Electrical Code (NEC) American Society for Testing and Materials (ASTM) Underwriter's Laboratories, Inc. (UL) Insulated Power Cable Engineer's Association (IPCEA). National Electrical Manufacturer's Association (NEMA). Institute of Electrical and Electronic's Association (IEEE). American National Standards Institute (ANSI). National Fire Protection Association (NFPA). City of Houston Building Code 1-9 SLEEVES, CUTTING AND PATCHING: This Section shall be responsible for the placing of sleeves for all conduit passing through walls, partitions, beams, floors, roof, etc. Sleeves through below -grade walls shall be as specified and detailed on the plans. All cutting and patching will be done under another Division, but this Section will be responsible for timely performance of this work and layout of holes and setting sleeves. 1-10 EXCAVATION AND BACKFILL: Trenching and backfilling and other install the facilities specified herein requirements of Division 2 (95% of trenching or excavation is required be compacted to a condition equal earthwork operations required to shall conform to the applicable maximum standard density). Where in improved areas, the backfill shall to that of adjacent undisturbed earth and the surface of the area restored to the condition existing prior to trenching or excavating operations. The plans indicate information pertaining . to surface and sub -surface obstructions; however, this information is not guaranteed. Should obstructions be encountered whether or not shown, the Contractor shall alter routing of new work, reroute existing lines, remove obstructions where permitted, or otherwise perform whatever work is necessary to satisfy the purpose of new work and leave existing surfaces and structures in a satisfactory and serviceable condition. 1-11 CLEANING: Clean lighting fixtures and equipment. Touch-up and refinish scratches and marred surfaces on panels, switches, starters, and transformers. 1-12 TESTS AND INSPECTIONS Tests and inspection requirements shall be coordinated with BCEI.. Date for final acceptance test shall be sufficiently in advance of completion date of contract to permit alterations or adjustments necessary to achieve proper functioning of equipment prior to contract completion date. Conduct re -tests as directed by BCEI on portions of work or equipment altered or adjusted as determined to be necessary by final acceptance test. No resultant delay or consumption of time as a result of such necessary re -test beyond contract completion date shall relieve Contractor of his responsibility under contract. Put circuits and equipment into service under normal conditions, collectively and separately, as may be required to determine satisfactory operation. Demonstrate equipment to operate in accordance with requirements of these specifications. Perform tests in the presence of BCEI. Furnish instruments and personnel required for tests. At the time designated by BCEI, the entire system shall be inspectedby th.e Architect and. Engineer. The contractor or his representative shalt be .present at this inspection. P P Panelboards, switches, fixtures, etc, shall be cleaned and in operating condition: Certificates and documents required hereinbefore shall be in order and presented to BCEI prior to inspection. Panel covers, junction box covers, etc:, shall be removed for visual inspection of the wire, bus bars, etc. After the inspection, any items which are noted as needingto be changed P 9, or corrected in order to comply with these specifications and the drawings shall be accomplished without delay. PART 2: PRODUCTS - ELECTRICAL 2-1 ALL PRODUCTS: All products shall be listed by Underwriter's Laboratories and have the U.L. label affixed. 2-2 RACEWAYS AND FITTINGS: Except as noted or otherwise specified, all wiring _shall be installed in galvanized rigid steel conduit or electrical steel tube (EMT) of the proper size to contain the number of conductors required in accordance with the latest edition of the N.E.C. Where conduit sizes are shown on the drawings, those shall take preference. Provide EMT in sizes up to 4 inches when concealed or not .exposed to damage; Rigid steel, galvanized for underground use, where exposed to damage, or in exterior applications; Rigid galvanized steel where embedded in concrete or masonry construction. Minimum size shall be 3/4 inch except for fixture whips not exceeding 6'- 0" long. Branch circuits run underground shall be run in Carlon Schedule 40 PVC conduit. Install ground wire in accordance with NEC table 250-95. All conduit systems shall utilize compression type fittings. Conduit shall be run concealed in finished areas. Conduit may be exposed in mechanical rooms and where otherwise indicated. 1n finished areas with no suspended ceiling, all conduit shallbe painted to match ceiling. Concealed conduit shall run in as direct manner with as long bends as possible. Exposed conduit shall be run parallel with, or at right angles to the lines of the building; and all bends shall be made with standard conduit ells or conduit bent to not less than same radius. Not more than equivalent of four quarter bends shall be used in any run between terminals and cabinet, of between outlet or junction boxes. Approved conduits shall be used in lieu of conduit ells where ease of installation and appearance warrants their use. Conduit joints shall be made with approved couplings and unions. Provide #30• nylon pulling line in all conduits in which permanent wiring is not installed. Branch circuit conduits installed in concrete slabs on fill or grade shall be positioned in a manner to ensure complete concrete cover. In no case shall such conduits be exposed below or above the slab surfaces, or penetrate the waterproof membrane. At locations where feeder, or other large conduits, must pass through slabs on fill or grade, the conduit shall be PVC coated rigid galvanized steel, extended 6 inches into the earth, and 2 inches above exposed surface of slab. All conduit shall be securely fastened and supported using hot galvanized malleable iron one -hole pipe straps, clamps, hangers or other means pproved by the engineer. Supports shall be as required by NEC Table 346-12. Tie wire shall not be used as support or securing means. Support conduit independently of ceiling hanger wire. 2-3 OUTLET AND JUNCTION BOXES: Provide an approved galvanized outlet box with adequate volume for number of conductors concerned. Provide standard galvanized switch boxes of the required number of gangs. Switch boxes for exposed wiring shall be handy boxes or approved equal. Outlet boxes for receptacles shall be similar to Universal 52151 with suitable raised cover. Receptacle boxes on exposed wiring shall be handy boxes or approved equal. Weatherproof boxes where necessary shall be FS or FD. Outdoor boxes shall be NEMA 3R, with conduit connections made by Myers Hubs. See notes and details on Drawings for special box requirements. Provide junction boxes required to facilitate installation of the various conduit systems. Provide support boxes required for risers, each complete with approved cable supports as described elsewhere in this Division. Outlet boxes for drywall shall be standard galvanized switch boxes. Provide coverplates for all outlet boxes. Provide junction boxes and conduit system for all electrical systems: (i.e. electrical, sound, security, fire alarm, CCTV, cameras, CATV, intercom). 2-4 PULL BOXES: Pull boxes shall be provided for conduit systems as required and shall be constructed of galvanized steel of not less than gauge and size specified by National Electrical Code. Where two or more feeders pass through a common pull box, they shall be tagged to indicate clearly their electrical characteristics, circuit number, and panel designation. 2-5 WIRE AND CABLE: All wire shall be new and continuous without weld, splice, or joints throughout its length. It must be uniform in cross-section, free from flaws, scales and other imperfections. Wire shall be soft drawn, annealed, 98% pure copper, with tin coating. Aluminum wiring . is not acceptable. Acceptable manufacturers for conductors and cables include, but are not limited to, Alcan Aluminum Corporation, American Insulated Wire Corporation, General Cable Corporation, Senator Wire and Cable Company, and Southwire Company. Acceptable manufacturers for connectors and splices shall be AMP, Hubbell/Anderson, O.Z. Gedney, and 3M Company. A. TYPES: 1. Provide code gauge type "THHN" or "THWN" insulation. 2. All wire No. 8 and larger shall be stranded. All wire No. 10 and smaller shall be solid. Minimum wire shall be No. 12, unless otherwise shown on Drawings. 3. Provide type "RHH" or other 90 degrees C insulation wiring for branch circuit wiring installed through continuous rows of fluorescent fixture bodies. 4. Fire alarm device wiring shall be 300 volt, PVC jacket UL- listed when routed ina raceway. The jacket shalt be UL listed for use in air plenums when a raceway is not used. 5. Control wiring shall be No. 14 AWG copper conductor unless otherwise shown; 600 volt rated insulation. 6. Open low voltage wiring in return air plenums shall be plenum rated or run in conduit. All wiring in mechanical rooms electrical rooms and other areas subject to physical damage shall be run in conduit. B. COLOR CODING: Conductors shall be color coded in accordance with the governing authority requirements or as follows (if conflicting, local governing authority shall override) : 120/208V 277/480V 1. Neutral: White. 2. Phase A: Black. 3. Phase B: Red. 4. Phase C: Blue. 5. Ground: Green. 1. Neutral: Gray 2. Phase A: Brown 3. Phase B: Orange 4. Phase C:. Yellow 5. Ground: Green C. SPLICES: Splices, where required, shall be fully made up in outlet boxes with compression crimp -on type splice connectors and at least 12 inches tagged, end left for the fixture hanger. Where local requirements specify certain colorsfor phases and neutral, etc., these shall become the standard for this project. Joints and splices will not be permitted in mains or feeder. Joints in branch circuits will be permitted where branch circuits divide,. and then shall consist of one through -circuit to which the branch shall be. spliced. Joints shall not be left for the fixture hanger to make:. Fit joints and splices with Buchanan Series "2000' solderless connectors complete with insulating caps or properly sized wire nuts. 2-6 WIRING DEVICES: Acceptable manufacturers are . Hubbell, or Pass & Seymour. A. SWITCHES Furnish and install generally where indicated on the Drawings. Coordinate final color and exact locations with architect. Wall switches shall be 20 amp, 120-277 volt and shall be Hubbell Style Line Series 21 or equal as follows: 1. SINGLE POLE SWITCHES: 2121-W, White. 2. DOUBLE POLE SWITCHES: 2122-W, White. 3. THREE WAY SWITCHES: 2123-W, White. 4. FOUR WAY SWITCHES: 2124-W, White. B. DIMMERS: Provide Lutron "NOVA T Star" series wall box dimmers sized to handle the load. Gang dimmers without removing heat sink fins and mount under a common Lutron coverplate. C. RECEPTACLES: Furnish and install generally where indicated on the Drawings. Coordinate final color and exact location with architect. Receptacles shall be Hubbell or equal as follows: 1.Duplex 20A-125V-self grounding: 2162-W (White, Nema configuration 5-20R). 2. Simplex 20A-125V-Self Grounding: 2161-W (White, Nema configuration 5-20R). 3. Isolated grounding 20A-125V: IG-2162 (Orange, Nema configuration 5-20R.) 4. Clock hanger receptacle 20A-125V: 5361-CH (Brown with stain finished stainless steel plate with hanger, Nema configuration 5-20R). 5. Ground fault circuit interrupter (GFCI) receptacle 20A-125V; GF-5362-W. (White with indicator light Nema Configuration 5- 20R, with "Feed through" connectors capable of protecting connected downstream receptacles on a single circuit, and of being installed in a 2-3/4' deep outlet box without adaptor). 6. Equipment receptacles shall be coordinated with owner/manufacturer requirements and the correct and appropriate receptacle and cover plate then installed. D. PLATES: 1. Furnish and install plates on all outlet boxes. 2. Plates in offices and similar finished areas shall be Hubbell smooth thermo-plastic. 3. Wet Locations: Provide Taymac or Carlon Nema 3R, impact resistant polycarbonate enclosure. Enclosure shall be suitable for wet locations when in use. 4. Provide Hubbell stainless steel type 302/304 coverplates installed in kitchens. 5. indoor Exposed Raceway Systems: Stamped sheet metal, sized to match box without overlapping sharp edges. E. Floor boxes shall be cast iron as manufactured by Hubbell and as indicated below: (Note: If floors are wood, provide a Hubbell cast iron floor box and flush cover designed for this application.) 1. Slab at grade (dual level, fully adjustable type 1). a. Single gang: #B-2436 w/#SB-3083 carpet flange. b. Two gang: #B-4233 w/#SB-3084 carpet flange. c. Three gang: #B-4333 w/#SB-3085 carpet flange. 2. Slab above grade (shallow, semi -adjustable, type II) a. Single gang: #B-2414 w/#SB-3083 carpet flange. b. Two gang: #B-4214 w/#SB-3084 carpet flange. c. Three gang: #B-4314 w/#SB-3085 carpet flange. 3. Cover plates shall have brass finish as follows: a. #S-3825 for duplex flap for duplex receptacles. b. #S-2425 for data/communications. c. Provide appropriate coverplate for special purpose receptacles. Unless noted to the contrary on plans, or directed otherwise during the progress of the Work, wiring devices shall be set as follows: 1. Switches 42 inches above finished floor. 2. Duplex and single receptacles 15 inches above finish floor except where located above counters or interferes with shelving or as requiredby local codes. 3. Wall telephone outlets, except where counters or shelving interferes 15 inches above finished floor. 4. At locations above counters, set devices 1 foot-0 inches above counter tops, verify exact mounting height with the architect. 2-7 DRY -TYPE TRANSFORMERS: Provide dry type, two -winding transformers with primary and secondary voltages and KVA ratings as shown on plans. Transformers shall operate at 60 Hertz. All transformers shall be manufacture with standard materials and components. When noted on the drawings, provide K-rated transformers rated for non -linear loads. Acceptable manufacturers are General Electric Company, Square D Company or Siemens. All cores shall be constructed of high grade, non -aging silicon steel with high magnetic permeability, and low hysteresis and eddy current losses. Magnetic flux densities are to be kept well below the saturation point. The core laminations shall be clamped together with structural steel angles. The completed core and coil shall be isolated from the base by means of rubber, vibration -absorbing mounts. There shall be no metal -to - metal contact between the core and coil and the enclosure. The vibration isolating system shall be designed to provide a permanent fastening of the core and coil to the enclosure. Sound isolating system requiring the complete removal of all fastening devices will not be accepted. Windings shall be copper or electrical grade aluminum terminated on tin plated or copper bars. Foil windings are not acceptable. The transformer core shall be visibly grounded to the enclosure by means of a flexible grounding conductor sized in accordance with NEMA, IEEE and ANSI standards. Transformer coils shall be of continuous -wound type construction and shall be impregnated with non -hygroscopic, thermo-setting varnish. Transformers shall be enclosed in drip -proof, metallic enclosures designed to provide for air cooling and prevent accidental contact with live conductors. Wiring compartment shall be located below the core and coil and cooled by air circulation or insulated from the core and coil by means of a suitable thermal insulation barrier. Transformer exposed to weather or installed in a sprinkled area shall have rain shields on all openings. Entire transformer enclosure shall be cleaned, phosphatized, primed and painted with a grey, baked enamel. Transformers shall operate at 100% nameplate KVA rating continuously while in a 40 degree C ambient without exceeding the rated average winding temperature rise of the ANSI insulation system as described below. Temperature rating shall be as follows: RATING PHAS.E INSULATION - TEMP. RISE 0.025 through 3 KVA 5 through 25 KVA 3 through 15 KVA 37-1/2 KVA and larger 30 KVA and larger Single Single Three Single Three Type B - 80°C Type F - 115'C Type F - 115'C Type H - 150°C Type H - 150°C Transformers shall have minimum full load rated taps in high voltage winding as follows: 3 through 25 KVA 2 15 through 300 KVA 6 Maximum sound ratings KVA 0 - 9 10-50 51 - 150 151 - 300 DB 40 45 50 55 - 5% FCBN - 2-1/2% TAPS, 2 above and 4 below normal shall be as follows: Provide a nominal 3-1/2" high, 2500 PSI (28 Day) concrete reinforced pad with number 6 welded wire mesh. The pad shall conform to the shape of the transformer and extend at least 3 inches beyond the length and width of the transformer. All corners of the pad shall .be rounded. Install floor mounted transformers on sized rubber -in -shear properly vibration isolators. Trapeze mounted transformers shall use rubber -in -shear hangers. Wall mounted transformers shall not be mounted directly to the wall without vibration isolation. Route conductors in a minimum of 2 feet of flexible steel conduit to transformer enclosure. Provide grounding conductor sized per NEC, connected to the building grounding electrode system. 2-8 PACKAGED DIESEL ENGINE GENERATORS Generator provided by BCEI, received and installed by contractor. Generator shall be Cummins 1500KW, rated for continuous standby service, 3-phase, .8 P.F., 480/277VAC, 60 cycle. Generator shall contain but not Limited to the following accessories: battery charger, day tank, engine generator set, muffler, remote annunciator, remote stop switch, starting battery, radiator -mounted load bank, (2) jacket water heaters, (1) 2500A circuit breaker, (1) 1200A circuit breaker, customer communication module, and fuel priming pump. Contractor shall obtain from BCEI a copy of the generator submittal. Contractor responsible for coordinating with shop drawings all installation requirements for complete installation, including, but not limited to: all control wiring, remote monitorring installation and wiring, control wiring between generator and (2) transfer switches, grounding per N.E.C., and connection of power to all locations on generator not already included. Coordinate remote monitorring requirements with systems monitorring contractor and Cummins. Contractor responsible for coordinating with, and assisting, Cummins during all testing procedures and submitting reports. These tests include Field Tests and Observation Reports, Certified Test Reports, Certified Summary of Performance Tests, Factory Test Reports, Exhaust Emissions Test Reports, Certification of Vibration Compatibility, and Sound Measurement Test Report. 2-9 GROUNDING: Provide electrical service, equipment and wiring device grounding as shown, scheduled and as specified. The types of grounding include, but are not limited to, the grounding bonding of all equipment devices, building steel piping, and as required by the National Electrical Code, Local Inspection Department and Power Company. A grounding conductor is required for all feeders and circuits. Provide grounding products manufactured by Copperweld and Cadweld. Ground rods shall be 3/4" inch diameter by 10 feet long construction with copper jacket and a steel core. Ground clamps shall be copper except for steel or iron pipes in which the clamps shall be galvanized iron. Conductors shall be connected by means of an approved pressure connector or clamp. Perform a ground resistance test using a biddle megger. The system resistance shall not exceed 5 OHMS. Provide additional electrodes as required (refer to 250-84 of the NEC). Test shall not be conducted following wet weather. Provide personnel and instruments to conduct these tests and submit certified test for review. A. BUILDING STEEL AND PIPING SYSTEM: Install a bonding jumper between building steel and metallic piping systems to bond them to the electrical grounding system. B. NEUTRAL: The neutral shall be grounded only at the service entrance and other separately derived systems. The neutral shall be kept separate from the grounding system and shall not be used as a ground. C. GROUNDING SEPARATELY DERIVED ALTERNATING CURRENT SYSTEM TRANSFORMERS: The center point (neutral) of each wye connected transformer shall be bonded to the case and a grounding electrode conductor. The grounding electrode conductor shall be connected to building steel, a ground rod or the building grounding system, if building steel or ground rod are not possible. D. GROUNDING CONDUCTOR: A grounding conductor and metallic conduit system shall bond all equipment served by the electrical system. Provide a flexible bonding jumper for isolated metallic piping and ductwork and around expansion fittings and joints. E. CONDUIT GROUNDING BUSHING: Conduit terminating in equipment that has a ground bus such as switchboards, panelboards, etc., shall have grounding bushings installed. Ground each conduit by means of a grounding bushing and to the ground bus in the equipment. F. MOTORS: The frame of all motors shall grounded. H. REMOTE PANELBOARDS: Provide a grounding electrode conductor at all remote panels as required by the NEC. I. LIGHTING FIXTURES: All light fixtures shall be grounded. Flexible fixture whips are not considered to be grounded. J. RECEPTACLES: All receptacle shall be grounded. Receptacles shall use an approved grounding yoke. 2-10 PANELBOARDS: Furnish and install power distribution, lighting and appliance panelboards as indicated in the panelboard schedule and as shown on the plans. Power distribution panelboards shall be equipped with fusible switches or circuit breakers as shown on the one line diagram. Panelboards shall be equipped with thermal -magnetic, molded case circuit breakers of frame and trip ratings as shown on. the ..schedule. Manufacturer shall be the same as the manufacturer of the equipment furnished by the owner. Panelboard bus structure and main lugs or main breaker shall have current ratings as shown on the panelboard schedule. Such ratings shall be established by heat rise tests with maximum hot spot temperature on any connector or bus bar not to exceed 50'C. rise above 40°C ambient. Heat rise test shall be conducted in accordance with Underwriters Laboratories Standard UL 67. The use of conductor dimensions will not be accepted in lieu of actual heat tests. All current carrying parts of the bus shall be tin plated copper. Bus structure shall be insulated. Bus bar connections to thebranch circuit breakers shall be distributed phase or phase sequence type and shall accept bolt -on circuit breakers for lighting and appliance panelboards. Provide a bare uninsulated and/or insulated ground bus and full or double size neutral bus as required and indicated in each panelboard schedule. Each panelboard shall have an engraved bakelite nameplate. Nameplates shall be white with black letters and show panel designation. Nameplates shall be attached with stainless steel screws. Place a neat, carefully typewritten directory card identifying the load served by each branch circuit in the frame on the panel door, under a clear plastic cover. Spares and spaces shall be written with erasable pencil for future use. A. Circuit Breakers Where circuit breakers or fuses are applied in compliance with the series combination ratings marked on the equipment by the manufacturers, the equipment enclosure(s) shall be legibly marked in the field to indicate the equipment has been applied with a series combination rating. The marking shall be readily visible and state "caution - Series Rated System." (NEC 110-22). Nameplate shall identify replacement components. 1. Distribution Panelboards: Circuit breakers shall be equipped with individually insulated, braced and protected connectors. The front faces of all circuit breakers shall be flush with each other. Large, permanent, individual circuit numbers shall be affixedto each breaker in a uniform position. Tripped indication shall be clearly shown by the breaker handle taking a position between "ON and "OFF". Provisions for additional breakers shall be REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC MAR 14 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 0 2014 10400 Rodgers Road HOUSTON, TEXAS 77070 Ph: 281-374-8644 Fax: 281-374-8992 Gensler -Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 Cn ISSUES & REVISIONS No. Date Description 1 02/17/2014 ISSUE FOR PERMIT ELECTRICAL SPECIFICATIONS DRAWN: WAM REVIEWED: RWB PROJECT NO.: C1047.00 SHEET NO. E0.2 PERMIT CENTER PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. , ` such that no odditkono| connectors will be required to odd breakers. Circuit breakers ahoU be of the fnonne size, trip setting and interrupting capacity as indicated on the Current limiting circuit breakers shall be equal to Square O Company "I -Limiter" 3ehea' Circuit breakers ohoU be conventional interrupting capacity otherwise noted) but in no oam: be |000 than the following symmetCical amperes RMS. CONVENTIONAL INTERRUPTING CAPACITY 10,000 A|C 10,000 AJC 42,000 AIC 42,000 AJC 42,000 A|C 42,000 A|C 42,000 A|C 14,000 A(C 22,000 AJC 30,000 AJC 3O'OOO /8C 30,000 A]C 30,000 /UC 50,000 A]C HIGH INTERRUPTING CAPACITY 65,000 A|C 65,000 A|C 65,000 AIC O5'OOO /UC G5'00OAJC 65,000 AIC 85^OOO A|C 25~000 AIC 65,000 AJC ` 35,000 /UC G5`OOO A]C 85'OOO AIC 65,000 A|C 65,000 A|C CURRENT Uk40NG 200,000 AJC 280,000 AJC 200,000 A]C 200,008 A|C 200,000 /UC 200,000 AJC 200,000 AJC 200,000 /UC 200.000 A]C 200'000 A]C 200'000 AIC 200.000 A|C 200,000 A|C 200,000 AJC 2' Volt Lighting ponoiboorda: ` All | circuit breakers shall be vertically .shall not be installed in branch breaker spaces. Circuit breakers shall be bolt-6n thermal -magnetic, molded case circuit breakers. Breakers shall be 1, 2 or 3 pole with an Integral crossbar to assure. simultaneous opening of all poles in multiple circuit. breakers. Breakers shall have an over - center, tri-free, toggle -type operating machinist with quick-, make, quick -break action and positive handle indication. Handles shall have "ON", "OFF" and "TRIPPED" positions. Circuit breakers shall be UL listed in accordance with UL ~.^...... ^~~ and shall^be rated. 27' `~'~~ ~c rpy= pole, 15 30 amperes) or 480Y/277 volts ac (2 and 3 pole) with continuous current ratings as noted on the plans. Interrupting ratings shall be 14,000 rms symmetrical amp I eres at 277 volts ac (single pole) or 480Y/277 volts ac (2 and 3 pole). - Single pole, 15 and 20 ampere circuit breakers intended to switch fluorescent lighting loads on a regular basis shall carry the SWID marking. The lugs for terminating conductors shall be rated at 75* c. 3' 240 Volt Lighting and Appliance Pune|boord: All main circuit breokero' shallbe verticallymounted and shallnot be installed in branch breaker spaces. Circuit breakersa-ohoU be bolt -on thermal- m ag neDn, molded uooe circuit breakers. Breakers oho{| be 1. 2' or J pole with on integral crossbar to oaoune simultaneous opening of all. poles in rnu|t[p|o circuit breakers. Bnnukena oho|} have on over - center, th--frnm, toggle -typo operating machinist with quick - make, quick -break action and positive handle indication. Handles aho|) have "ON",''OFF" and "TRIPPED" positions. Circuit bnaohmno ohoU be UL listed in accordance with UL standard 489 and oho|> be rated 240 volts oo rnoxirnurn with continuous current rating as noted on the p|onu' The lugs for terminating conductors oho|| be noted at 75' c. Sing|e pole 15 and 20 ampere circuit breakers ohoU be UL listed as "Switohing Breakers" at 120V oc and carry the SVYD marking. UL C|ooa A ground fault circuit protection ahoU be provided on all receptacle circuits nerving wet oraoa and on all 120V oo branch circuits on specified on the plans or pone|boord schedule. This protection shall be on integral part of the branch circuit breaker which also provides overload and short circuit protection for branch circuit wiring. Tripping of o branch circuit breaker containing ground fault circuit interruption oho|| not disturb the feeder circuit to the pone|boord. A single pole circuit breaker with integral ground fault circuit interruption aho|| require no more pone|boord branch circuit space than o conventional circuit breaker. Circuit bnaohans aho|| be rated 10.000 A|C at 240V unless otherwise noted on plans. B. Fusible Switches All fusible ewhzhaa ahoU be quick-make,quick-break with visible blades and dual h tihandles hU physically indicate "ON" and "OFF" positions. Switches shall be lockable only in the "OFF" position and accept three industrial type heavy duty padlocks. Switch covers and handles' shall be interlocked to prevent opening in the "ON" position. A means shall be provided to permit authorized personnel to release the interlock for inspection purposes. Switches shall include positive pressure rejection type fuse clips for use with UL class, R fuses and be UL labeled for 200,000 AIC. Class "J" fuses shall be UL labeled for 200,000 AIC. The lugs for terminating conductors shall be rated at 75' c. C. Cabinets and Fronts The pone|boord bus oaomrnbk' ahoU be enclosed in o steel cabinet with multiple knockouts. The rigidity and gouge of steel to be as opooUled in UL Standard 50 for cabinets. Wiring gutter shall be in accordance with "L S`"''""'" "' for p"'="""'"s' The "°^ aho|| be fabricated from galvanized steel or equivalent rust resistant steel. Each front aho|| include o door and have o flush, cylinder tumbler -type lock with catch and spring -loaded stainless steel door pull. All pone|bwurd lock aho|| be keyed alike. Fronts oho|/ have adjustable indicating trim o|onnpo which aho|| be completely concealed when the doors are closed. Doors oho|| be mounted with umrnp|otek/ concealed steel hinges. GOOA panelboard front mho|| have exposed trim clamps. A circuit directory frame and oond with o clear p|oat|o covering aho|| be provided on the inside of the door' Where required by |000| code, provide Norno 3R enclosure where installed in a sprinklered area. D. Safety Barrier The distribution oonobnord interior assembly ohoU be dead front with panelboard front nanonvod. Main lugs or main breakers aho|| have barriers on five aideo. The barrier in front of the main lugs oho|| be hinged to o fixed port of the interior. The end of the bus structure opposite the rnoino shall have barriers. E. integroted Equipment Short Circuit Rating Each pone|boond, as o omnnp|mte unit, ahoU have o short circuit current rating equal to or greater than the integrated equipment rating shown on the pone}bnurd schedule or on the' plans. This rating aho1| be established by testing with the over -current devices mounted in the pone|boord. The short circuit tests on the over - current devices and on the pone|boord structure aho|| be made simultaneously by connecting the fault to each over -current device with the pone|boord connected to its rated voltage source. Method of testing aho|| be per Underwriters Laboratories Standard UL 67. The source oho|| be oopob|m of supplying the specified pone|boond short circuit current or greater. Testing of pone|bVord over - current devices for short circuit rating only while individually mounted is not ouuapzob|e. Also, tooting of the bus structure alone is not acceptable. Pone|boords oho|| be marked with their rnox|rnurn short circuit current rating at the supply voltage and mho|i be UL 2-11 MANUAL MOTOR STARTERS: k4onuo| starters ahoU consist of o rnonuo|h operated toggle switch equipped with melting alloy type thermal overload relay. Thermal unit ahoU be of one-piece construction and interchangeable. U Starter h be inoperative if thermal unit is removed. Contacts shall be double breok, silver alloy, visible fromboth sides of starter. Manual starters oho|| " be 3quono "D"o|ooa 2510 or 3512 or approved equal. Provide the size and number of poles aho}| be as shown and required by equipment, served. Furnish red pilot light as indicated. ' All rnonuo| motor starter enclosures ohoU be NEMA 1, general' purpose enclosures, unless shown otherwise. Provide Nerna 3R enclosure where installed outside or in o ophnWwred area when required by |ouui code. MOTOR CONNECTIONS: Provide electrical and grounding connections to motors as indicated., Connections as follows: 1.Not less than 18inch 'length of Sealtite, extending from motor connection box to motor branch circuit conduit on outdoor and wet /000tkona' Provide Greenfield for inside dry locations� 2. }nmtoU connections mechanically neoun:° assuring electrical continuity, proper and effective grounding. INSTALLATION OF MOTOR STARTER |notoU motor starters in accordance with the manufacturer's written instructions, the applicable requirements of the NEC and the NECA^o "Standard of Installation", and recognized industry practices to ensure that products serve the intended function. 2-12 CURRENT - LIMITING FUSES: Provide 200.000 amp interrupting limiting fuses of the ompocitv and voltage indicated and scheduled. Upon completion of the building the contractor ohu|| provide the owner with apona fuses as shown below. A. 10% (minimum of 3) of each type and rating of installed fuses ohoU be supplied as spares. B. BUSSMAN spare fuse cabinets - Catalog No. SFC - shall be provided to store the above spares. Mains, Feeders and Branch Circuits 1. Circuits O to 600 ampere ahoU be protected by current |irnODng BU33MAN LOW -PEAK Dual Element Fuses, LPJ. All dual - element fuses ahoU have separate overload and short-circuit elements. Fuse shall incorporate a spriin- activated thermal overload element having o 284 degree Fahrenheit melting point alloy and shall be independent of the short-circuited clearing chamber. The fuse must hold 500% of rated current for o /nirnurn of 10 seconds and listed by Underwriters' Laboratories ' Inc., with on interrupting rating of 200,000 amperes r'rn.o. ` ayrnrnetrioa|- The fuses shall be. UL C|oma J. ` 2-13 SAFETY AND DISCONNECT SWITCH: A. Products shall, be designed, nnonufootured, tested and installed in compliance with applicable standards. ' 1. NEMA KS1 - Enclosed switches 2. Federal specification VY-S-885C-Heavy duty switches Products ahoU conform all applicable UL standards, including UL98 (standard for safety, ono\oead and dead front switches) and ahoUbe UL-labeled. Acceptable nnonufootunaro are: General Electric Company, Square D Company, or Siemens. Furnish and install avy duty type switches with the number of switched poles as indicated on the plans and specifications. All safetyswitches aho|| be NEMA Heavy Duty Type HD' and Underwriters Lobnrotuhea listed. B. Switch Interior All switches ahoU have switch blades which are fully visible in the "OFF" position when the door is open. Switches aoU have rarnnvob|o arc suppressor where neoeaoory, to permit easy 000eom to line aide lugs. Lugs shall be front narnovob|e and UL listed for 00rC and 75*C copper o|urninurn cables. All switches b|odoa and contacts aho|| be plated copper. C. Switch Mechanism Switches ohoU have o quick -make and quick -break operating handle and nnoohon|orn which ohoU be on integral part of the box, not the cover. Padlocking -no provisions nho|| be provided for locking in the "OFF~ position �� at |ooat three pod|noha. Switches shall have o duo| cover interlock to prevent unauthorized opening of the switch door when the handle is Jn the "ON" pooition, and to prevent closing of the switch rnoohon7orn with the door open' A rneona uhoU be provided to permit authorized personnel to release the interlock for inspection purposes, Handle position shall indicate if switch is D. Neutral Provide o solid neutral with the safety switch where o neutral is present in the circuit. E. Ratings Switches ahoU be horsepower rated foroc do as indicated by the p|ona' The fused switches shall have Class R rejection fUoo clips when required. Adjust |nod side terminal block as required to 000apz C)oao J fuses. UL listed short circuit ratings of the switches, when equipped with C|oaa R or C|oao J fuses, nho|| be 200,008 symmetrical ompenoa' F. Enclosures 1. Indoor switches ahoU be furnished in NEMA 1 enclosures. 2. Outdoor switches, switches located in wet areas, or inside o sprinkled area oho|| be furnished in NEMA 3R enclosures. G. Service Entrance Switch ahoU be suitable for use as service entrance equipment when installed in accordance with the National []eothoo| Code. H. Hubs: Provide bolt -on hubs for rainproof or wet area applications. 2-14 LIGHTING FIXTURES: All fixtures ohoU conform to all applicable UL standards and ahoU be UL label including damp and wet location ratings. All fluorescent boUootn ohoU oornpk/ with certified boUoot manufacture (CBM) standard and CBM labeled. Acceptable rnonufootunaro for boUuato are Advance Transformer Company or Magnetek Universal Manufacturing. Acceptable rnonufooturana for |urnpo are General E|motMo Cu Ooronn io or North American Philips. General Electric "Constant Co|or~ is the only K4R-16 /ornp acceptable. Provide the size, type and rating of each light fixture h d scheduled. All light fixtures ahoU be complete with reflectors, lens, trim rings, flanges, |ornpa^ knno holders, ballast, starters, fuses wiring, earthquake o|ipn' etc. to provide o complete functioning light fixture. A. Lighting Fixture 1' Fluorescent Fixtures o. Fixture boUuot and |ornp holders mhoU be pre -wired and installed. Fixture ahoU be equipped with o top 000eom plate with knockouts for conduit entry. Fixture nhoU also include knockouts at each end plate for conduit entry. b. Provide 1100 lumen battery packs for emergency operation when specified. 2' Incandescent Fixtures o. Fixtures ahoU be pre -wired equipped with frorno in kit and o integral thonno| protection required by UL for n:onommd fixtureo, b. Provide appropriate trim rings for recessed mounted fixtures compatible with the ceiling in which the fixture is inntu||od' o. All |onn90 aho|| inside frosted unless otherwise noted or scheduled. 3. High Intensity Discharge Fixtures (HID) o Fixtures nho|| bepre-wired with frame-inframe-in kit and integral thermal protection required by UL for recessed fixtures. Ballast shall be. encased and potted and mounted on the frame -in kit. b. Provide remote ballast mounted on a separate mounting plate where indicated or scheduled. Ballast shall include a splice box. c. Provide a heat resistant glass shield below the lamp to contain mnnp y/oua envelope and ARC tube to prevent tnarn from fo|||no to the floor and causing damage to life and property. Lonnpa rated for open bottom fixtures may be used in lieu of the g|ooa shield if approved by the engineer, d. Provide o fuse and fume holder installed on the line side of each bo||ont to prevent branch circuit from tripping due to o faulty bo||oot' The fuse and fuse holder ohu|| be mounted in o junction box for recessed fixtures and in the base of all | The f holder poles. e fuse o er uho|lbe waterproof when installed in damp or wet |000tinno' Fuse size and tvpe oho{| be as recommended by ballast manufacturer. 4. Exit signs o. Exit signs ahoU rnoot all federal, state and local codes. b. Provide fire o|onn interface neloy when required to flash exit signs. o' Provide battery packs for emergency operation when B. Ballasts - Coordinate with Light Fixture Schedule 1. Fluorescent o' Electronic boUont ohoU be high power factor (90% min/mum), operate lamp at 20 KHZ, |eoo than 20% total harmonic content, full light output` crest factor less than 1'8y:. porra| |ornp oonfiguroton, rnu|ti-|ornp' doam "P" thermally protected` sound ~A" rating, encased and, potted and 50 degrees F rnin|rnurn starting temperature. Provide 5 year warranty parts and labor. Bo/|oat shall be Advanced Mork V or N|ognebsh HP Series. b. Magnetic ballast oho|| be energy saving, high power factor, rapid start, o|oos P thermally protected, encased and potted' sound "A" noting, and o 60 degree F temperature rating. Bo||oat oho(| be C8K4 certified an ETL and UL approved. BoUoot eho|| be Advance Mork III or equal by Magnetek Universal. c. All outdoor boUoot unless otherwise noted ahoU be high power factor, rapid start, | P thermally protmotmd, encased and potted, sound rating B and o O degrees F temperature rating. _Bol|oat aho|| be CBM certified by on ETL and UL approved. d' Provide suitable dimming bo|\ont where indicated. o. Compact fluorescent bo||ont shall be high power footor, sound rating ~A" and UL approved. 2' HID o Provide high transformer with a -20 degree F temperature rating. Ballast shall hove a of "B" for lamps less, than 400 watts. Ballast ~ for recessed downlights.or located remotely mhoU be encased' and potted and nhoU be provided with o splice box. Provide 120 volt top for . auxiliary |ornp when specified. C. Lorn Light Fixture Schedule 1' F03fluorescent |onnpm` ohoU be 32 watt energy saving and 4100 degree K.' 2, All in-candescentiornpmahoU be insidefrosted, extended life rated for 2500 hours unless otherwise noted. 130 volt lamps may be, used to provide extended life. D. Coordination ` 1 The contractor shall verify the type of fixtures with the ceiling types as indicated on the drawings. Any discrepancies shall immediately be brought to BCEI's attention before the contractor p|ooao his order and accepts delivery. Fixtures aho|{ fit exact in the type of ceiling scheduled. Provide o|outor fnornen, tCirn rings and other accessories required for o correct fit. 2. Provide supports attached to structural rpernbor to support fixtures when the ceiling ayuzern cannot maintain support. Provide separate supports for all recessed ceiling mounted HID fixtures. 3. Refer to architectural reflected ceiling plan for the exact location of all light fixtures. Notify the architect for any discrepancies or conflicts with structural architectural, nnoohonioo| piping or ductwork before installation. E. Mounting 1. Pendant or surface mounted fixture ahoU be provided with required tidevices d accessories, includinghickeys and stud -extensions, ball-`o|ignero, canopies and atarna' Locations of fixtures in rneuhonioo| on*oa ahoU be coordinated with rnachoninu| oontrootor. Mounting otenna of pendant fixtures shall be of the correct length to uniformly maintain the fixture heights shown on the drawings or established in the field. The allowable variation tolerance in mounting individual fixtures shall not exceed 1/4 inch and shall not vary more than //2 x`u/ from the floor mounting ne/gnz shown on the Drawings. Fixtures hung in continuous runs ohoU be installed absolutely |eve| and in line with each other. Hanging devices shall comply with Code requirements. Fixtures shall employ single - not twin - stem hangers unless otherwise ^``_~` 2. All structure mounted fixtures bracket mounted, pipe weightmounted and surface mounted) -shall, be provided with cables of suitable size and .port the weight of the fixture. Cob|ea ahoU be fastened around or fastened to the housing of the fixture. On pendant fixtures, suitable size and weight to support the weight of the fixture assembly shall connect the top of the pendant to the supporting structure by means of welding or bolting, and one vu/oty :uu/e unux onnnaoz the housing of the fixture no the, bottom of the pendant. Where more than one pendant per fixture occuro, only one pendant must be cabled. Track fixtures for pendant mounted track shall also be supplied with clip -on safety oob|ea of suitable size and weight to support the weight of the fixture. F. Electrical Connection 1. All light fixtures installed in on 000eooib|e suspended ceiling oho|/ be connected from o branch circuit junction box using 1/2" flexible rnoto/ conduit fixture pigtails not exceeding O'- O"' All fixtures nnua± be grounded by using o grounding conductor or the conduit system. Fixture to fixture wiring of fixtures installed in on accessible ceiling in not permitted. G. Fire Rated Ceiling 1. Provide fire robed canopy or enclosure for all fixtures nacaooed in o fire rated ceiling. The fire rated canopy or enclosure aho|| be as required by the UL design number listed in the UL fire. naoiatonow directory' Refer to architectural drawing for the UL design number. Coordinate with ceiling installer and manufacturer. H. Air Handling Fixtures 1. |nmtoU all air handling light fixtures with return air slot in the open position, if it is to be as on air handling fixture. Coordinate with mechanical contractor. i Rno| Inspection: 1 Remove all plastic and protective coating from all fixt Fixtures shall be thoroughly cleaned. Replace any damaged fixture or /mtu/c parts v/c/uumg reflectors, louvers, /e//u and rnoto| parts that show signs of corrosion. 2. All final incandescent |ornpn used during construction aho|| be replaced with new |onnpa. Replace all other defective boUoot. |ornpm or d/ouo|onad |ornpa^ showing signs of excessive usage. 3. Demonstrate proper operation of all fixtures and controls. 2-15 ELECTRICAL SERVICE ENTRANCE: A. POWER SOURCE: CwnterPoint Enorgy. B. SOURCE VOLTAGE: volt 30' 4w C. Field coordinate exact requirements and include in bid. 2-15 TELEPHONE RACEWAY SYSTEM A. Provide telephone/data service conduit. Coordinate exact requirements with tenant and include in bid. 2-16 MISCELLANEOUS ELECTRICAL CONTROLS AND WIRING A. The types of miscellaneous control devices and wiring include but not limited to the following. 1. Contactors 2. Relays. 3. Photocells 4. Time switches 5. Additional control wiring and aofatv devices as shown and specified. Various control devices, of on o|eothoo/ nature, for the safe operation and temperature control of the heating, ventilating, air conditioning and plumbing oyaton1n are provided under Division 15. All control wiring and conduit nhoU be furnished under Division 15. All power vv|hng 120 volt or larger aho|| be provided by Division 16. B. CONTACTORS AND RELAYS: Provide contactors and relays with the number o/ poles, ampere -rating, is shown and specified for u complete function system. Acceptable manufacturers are General Electric Company, Souon: D Company, ono Automatic Switch Company. Provide 2-wire or 3-wire control nnpdu|oa as required to operate lighting contactors. C. Control wiring oho1| be not |eom than #14 /ANG type TW, and ohoU be color coded and |obn|md with Brady markers throughout. Bundle � multiple conductors with Ty -Raps. ~� � RY BUILDING D_'_+' 2-17 UN\NTERRUPED POWER SUPPLY AJpS\ A. UPS modules ohnU be B. Becthcal Contractor shall be responsible for receiving and'setting the UPS modules and associated 1/0 cabinets and system cabinets. C. FIELD Assist as needed to supervise UPS installation, startup, and preliminary testing and adjustment. Participate in final tests, inspections, and adjustments. All testing shall be by an independent third -party. hired by the Electrical Contractor. 2-18 AUTOMATIC TRANSFER SWITCHES A. Automatic Transfer Switches oho| be mished � B. Electrical Contractor shall be responsible for receiving and setting the Automatic Transfer C. TESTING: Electrical Contractor shall assist in the testing ofthe Automatic Transfer Switches. 2-18 REMOTE POWER PANELS ARpP\ A. RPPs shall be owner -furnished. B. Electrical Cnntmnbn ohoU be, responsible for receiving C. TESTING: RECEIVED CITY OF TUKWILA Electdcal Contractor shall assist in the testing ���A�om�oTmn�� ' ����� O��M�6 FEB ^ ~ �°"" and uottinothe RPPx 10400 Rodgers Road Ph 2811-374-8644 ranax-u7w-uw92 Gen er ` S1 Two Lincoln Centre 5420 LBy Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 . � °~ �� I&S«���m��REVISuONS Date ' 1 O2/17/2O14 ISSUE FOR PERMIT w SHEETTfrLE ELECTIUCAL _________________ SHMNO. DRAWN: WAM REVIEWED: RWB PROJECT NO.:. C1047.0 ^� � END OFSECTION PERMIT CENTER PROPRIETARY.' NOT FOR DSCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. NEW UTILITY )nr�- TRANSFORMER�_ 1500kVA 480Y/277V SEC. (0002) UTILITY METERING CABINET 480Y/277V, 30, 4W, 2500A,100KAIC, N3R, SE RATED PER IREA UTILITY STANDARDS UT1UTY METER 0.F.C.I. N e'o 2500AF 2500AT • 100% LSIG MAIN SWITCHBOARD 'MSBO1000' 480Y/277V, 30, 4W, 2500A, SE RATED, N1, 42KAIC TVSS 0.F.C.I. 800AF 800AF 800AF 800AF �' •800AT FP 800AT FP 800AT F�'' 800AT 100%� 100%' 100% 100% LSIG LSIG LSIG L LSIG (002 003 ( 004 ( 005 OPT. STANDBY 600kW/750KVA GENERATOR GEN01000 480Y/277V, 30, 4W, 0.80PF WITH 1000 GALLON DIESEL FUEL STORAGE UL 142 BELLY TANK 100% 1000/3 100% OPT. STANDBY 600kW/750KVA GENERATOR GEN02000 480Y/277V, 30, 4W, 0.80PF WITH 1000 GALLON FUT. OPT. STANDBY DIESEL FUEL STORAGE 60014/750KVA UL 142 BELLY TANK GENERATOR GEN03000 480Y/277V, 30, 4W, 0.80PF S002 • • • • • 550kW • may.. limmiammis 1000/3 .` 100% GENERATOR SWBD 'GSB01000' 480/277V, 30, 4W, 2500A, 42KAIC S003 GENERATOR SWBD 'GSB02000' 2 480/277V, . 30, 4W, 2500A, 42KAIC • 1 800AF 800AT ( • 100% LSIG L SPARE 0.F.C.I. TVSS 240kA I 800AF "61180000%AT LSIG 1-" SPARE 900AF ) 900AT 1/ 100% 1 LSI 900AF 900AF 900AT )900AT 100% 100% LSI I LSI I2500AF )2500AT LSI N.O. I2000/3 •) LSI SPARE (LOAD BANK) 900AF ) 900AT 1100% LSI 900AF 900AF )900AT ) 900AT I100% 100% LSI LSI N G TVSS 240kA 0.F.C.I. 800AF ' -. 800AT 100% LSIG SPARE I I 800AF FP 8100AT • 100% LSIG SPARE (S004) (S005) 0.F.C.I. ( 006 ) AUTOMATIC TRANSFER SWITCH 'ATSA1000' 800A, 480V 3-POLE, 3-WIRE, 100KAIC OPEN TRANSITION MAIN DIST. 2 SWITCHBOARD 'MDSA1000' 800A, 480V, 30, 3W, 42KAIC 3 4 0.F.C.I. 600AF •N 600AF V 500AT ilEF,V 450AT 80% 80% LSIG LSIG . 400AF •V 400AT 80% Lz.zLSIG 600AF SPACE Colo ) C011) (012) --(SOO6)-- (5007) (S008) 0.F.C.I. ( 007 ) AUTOMATIC TRANSFER SWITCH. 'ATSB 1000' 800A, 480V 3-POLE, 3-WIRE, 100KAIC OPEN TRANSITION MAIN DIST. SWITCHBOARD 'MDSB1000' 800A, 480V, 30, 3W, 42KAIC 0.F.C.I.. 4 • 600AF ) 500AT 80% L� LSIG . 600AF •V 450AT 80% LSIG. L J . . 400AF V 400AT 80% LSIG 600AF • SPACE (013) (014) (015) 0.F.C.I. ( 008 ) AUTOMATIC TRANSFER SWITCH 'ATSC 1000' 800A, 480V 3-POLE, 3-WIRE, 100KAIC OPEN TRANSITION MAIN DIST. SWITCHBOARD 'MDSC1O0O' 800A, 480V, 30, 3W, 42KAIC 0.F.C.I. 2 . 600AF TV 500AT 80% L LSIG . 600AF . 400AF V 450AT y1-1 400AT 80% 80% L.. LSIG LSIG j 600AF SPACE • (016) (017) C018) 0.F.C.I. ( 009 AUTOMATIC TRANSFER SWITCH 'ATSD1000' 800A,- 480V 3-POLE, 3-WIRE, 1 OOKAIC OPEN TRANSITION MAIN DIST. SWITCHBOARD 'MDSD1000' 800A, 480V, 30, 3W, 42KAIC • 600AF �40V 500AT 80% L _ LSIG 0.F.C.I. - 600AF - 400AF •� 450AT Fe 3 4OOAT 80% 80% L { LSIG L- LSIG 600AF SPACE ( 019 ( 020 021 0.F.C.I. KK 400A/3P •l 500A/3P •J N.O. ( 022 ) STATIC UPS SYSTEM 'UPSA1000' 250kVA/250kW, 1.0pf 480V, 30, 3W, INPUT 480V, 30, 3W OUTPUT 0.F.C.I. Z 023 400A/3P j N.C. k KK ( 024 ) (B002) B001) I a MAINTENANCE BYPASS CABINET 'MBCA1000' 600A, 480V,. 30, 3W, 42KAIC 0.F.C.I. PDU 'PDUA1000' 300kVA, 480V, 30, 3W INPUT �rr 208Y/120V, 30, 4W OUTPUT 1 2 3 4 ) 500A 3P 6 `600AF 600AF 600AF •\ 600AF ) 450AT +) 450AT 600AF+) 450AT .) 450AT •) 450AT •/ 450AT 3P 3P 3P 3P 3P 3P (034)(0 5)(0 6) 0.F.C.I. ( FUT. ) / <A3> RPP 'RPP01000' 0.F.C.I. RPP RPP02000' 0.F.C.I. 0.F.C.I. KK 500A/3P •• N.O. 400A/3P NBC ( 025 STATIC UPS - SYSTEM 'UPSB1000' 250kVA/250kW, 1.0pf 480V, 30, 3W, INPUT 480V, 30, 3W OUTPUT 0.F.C.I. CO ) 400A/3P N.C. KK ( 027 ) (B004) (B003) gi A MAINTENANCE BYPASS CABINET 'MBCB1000' 600A, 480V, 30, 3W 42KAIC 0.F.C.I. n 500A la 3P PDU 'PDUB1000' 300kVA, 480V, 30, 3W INPUT ....7vN 208Y/120V, 30, 4W OUTPUT 0= 6 1 2 . 3 4 6 600AF 600AF 600AF 600AF 600AF 600AF •/ 450AT +) 450AT •J 450AT •) 450AT •) 450AT •/ 450AT 3P 3P -3P 3P 3P 3P RPP 'RPP03000' ( 037 )( 038 X. 039 ) 0.F.C.I. RPP 'RPPO4000' 1225A 3P /80% 1 225A 1)3P 80% 225A 80% \225A) )807 i 225A 80% 225A 1)3P 3P 8O% 225A N80% 1 225A) 80% 2r-215-A 1 )80% i 2251 V80% 1 225A 3P 80% 225A 3P T 80% 1 225A 3P 1 80% T 225A) 3P ( SD%I 225A �8O% 1 225A 80% 1 PANEL RPPO4D0: 42 POLE PANEL RPPO4D0' 42 POLE PANEL RPPO4A0' 42 POLE PANEL RPPO4A02 42 POLE PANEL RPPO3C0: 42 POLE PANEL RPPO3C04 42 POLE PANEL RPP03B0' 42 POLE PANEL RPP03B02 42 POLE PANEL RPPO2C0' 42 POLE PANEL RPPO2CO2 42 POLE PANEL RPPO2D02 42 POLE PANEL RPPO2D04 42 POLE PANEL RPPO1A0' 42 POLE PANEL RPPO1A02 42 POLE I IRPP01BD: � I PANEL 42 POLE PANEL RPP01B04 42 POLE I r II \A3,> FUT. <�C3> .Y RPP Y I'RPP05000' i -1 i I 225A 2251 2251r 225A- 225A 4.%3P 'e'�3P I. 4."‘ 3P � q.'80% '80% I 4'80% r'80% r--�rr_-'-_ IRPPO5A011P2PPO5A04 1iRPP05C0� �2PPD5C 04 I 42 11 42 POLE i i POLE PANEL ii PANEL -i PANEL iI PANEL 1 42 11 42 1 POLE 11 POLE II 1 1L_---JL____J 0.F.C.I. KK l 500A/3P N.0. 400A/3P N•C (028 ) STATIC UPS SYSTEM 'UPSC1000' 250kVA/250kW, 1.0pf 480V, 30, 3W, INPUT 480V, 30, 3W OUTPUT 0.F.C.I. (029) 400A/3Pf N.C. KK (Boo 6) (B005) I IN MAINTENANCE BYPASS CABINET 'MBCC1000' 600A, 480V, 30, 3W 42KAIC 0.F.C.I. PDU 'PDUC1000' 300kVA, 480V, 30, 3W INPUT 208Y/120V, 30, 4W OUTPUT 2 500A • 3P 5 6 ) 600AF 600AF600AF 600AF 600AF 600AF •/ 450AT •) 450AT +) 450AT •) 450AT •) 450AT •/ 450AT 3P 3P 3P 3P 3P • 3P (040)(041)(0 2) ,\ <,B3\> FLIT. <D5\> \Y/ RPP `\Y I'RPP06000' r 1 1 _ II 225A- 1 225AI 225A.? 225A, i 4''\ 3P 4`'N3P I A''‘ 3P '1'I3P T'80% t'80% 7'80% Y180% it -Ir--1---1 : PANEL 111 PANEL i li PANEL ii PANEL IIRPPO6B01 RPPO6B01 PPPO6D041RPPO6D04 42 I I 42 I 42 POLE 1 POLE 11 42 I it POLE II i n I li POLE 1 11 JL J 0.F.C.I. 400A 3P ."--• N• -•-••-. KK 500A/3P J N.O. STATIC UPS SYSTEM 'UPSD1000' 250kVA/250kW, 1.0pf 480V, 30, 3W, INPUT 480V, 30, 3W OUTPUT 0.F.C.I. ( 032 400A/3P • N.C. KK ( 033 ) (B008) B007) 5' MAINTENANCE BYPASS CABINET 'MBCD1000' 600A, 480V, 30, 3W 42KAIC PDU 'PDUD1000' 300kVA, 480V, 30, 3W INPUT 208Y/120V, 30, 4W OUTPUT 1 2 Ow4 500A •) 3P • I I 0 I600AF 600AF •) 450AT ) 450AT ! 450AT •) 45 AT •/ 450AT •/ 450AT 3P 3P 3P 3P 3P 3P ( 043 )( 044 KO 5 ) u 1 ( FUT. l A\ <D3;> ELECTRICAL ONE -LINE DIAGRAM ONELINE DIAGRAM GENERAL NOTES 1. REFER TO GENERAL ELECTRICAL NOTES, SYMBOLS, AND ABBREVIATIONS SHEET E0.1 FOR ALL SYMBOLS ON THIS SHEET. 2. REFER TO SHEETS E0.2 AND E0.3 FOR ELECTRICAL SPECIFICATIONS. 3. GROUND UPS EQUIPMENT AS RECOMMENDED BY MANUFACTURER, AS SHOWN ON SHEET El .2 AND REQUIRED PER N.E.C. 4. PROVIDE CONTROL WIRING BETWEEN UPS AND MAINTENANCE BYPASS CABINET PER MANUFACTURER'S ` RECOMMENDATIONS. 5. PROVIDE CONTROL WIRING BETWEEN UPS AND BATTERY CABINETS PER MANUFACTURER'S RECOMMENDATIONS. 6. REFER TO SHEET E4.1 AND E4.2 FOR FEEDER SCHEDULES, LOAD ANALYSIS, AND FAULT CURRENT DUTY SCHEDULE. 7. PHASE ROTATION SHALL BE A-B-C CLOCKWISE THROUGHOUT SYSTEM. 8. REFER TO SHEET E3:6 FOR GENERATOR CONTROL SYSTEM WIRING. MECHANICAL PANEL 'MDPA1000' 400A, 480V, 30, 3W, 65KAIC 1 2 3 4 j 125A i3P 0.F.C.I. I30A IN 15A •) 3P )3P 5 7-10. j 15A 1) 3P *)125A 3P j 30A •, 3P j (6) • 125A 3P PREP. SPACE (046) (0 7) (060) (061) Or I CRA- 01000 (DATA CENTER) ERP- 01000 (DATA - CENTER) L CON- 01011 (DATA CENTER) CON- 02012 (DATA CENTER) CRA- 09000 CON- 17010. 1 FUT. ) % r---�\\ / r---�\\ • 1 r�`7 1 1-11 r1 1 1 I I - I F-1 --�L- FUT. CRA- 05000 (DATA CENTER), MECHANICAL PANEL 'MDPB1000" 400A, 480V, 30, 3W, 65KAIC 1 2 3 4 125A 3P 0.F.C.I. 30A )3P 15A3P •} I 15A •) 3P 7-10 )125A 3P )30A 3P '1 (4) • 125A 3P PREP. SPACE C048) (049) (062) (063) CRA- 02000 (DATA CENTER) ERP- 02000 (DATA CENTER) L L CON- 03021 (DATA CENTER) CON- 04022 (DATA CENTER) CRA- 10000 CON- 18091 MECHANICAL PANEL 'MDPC1000' 400A, 480V, 30, 3W, 65KAIC 1 2 3 4 j 70A •) 3P 0.F.C.I. 50A ) 3P •)20A 3P 125A ) 3P 6-10 IN 3A I (5) •) 3P • 125A 3P PREP. SPACE 'TRNC1000': 480V:208Y/120V 45kVA, NEMA 1 050) (052) CO 3) (054) (055 ) CRA- 07000 (ELEC ROOM) CON- 13071 (ELEC ROOM) CRA- 03000 (DATA CENTER) ERP- 03000 (DATA CENTER) CON- 05031 (DATA CENTER) MECHANICAL PANEL 'MDPD10O0' 400A, 480V, 30, 3W, 65KAIC 1 2 3 4 0.F.C.I. IN 70A •) 3P I 50A •)3P 120A •) 3P 5 6-10 ,1 125A j 30A ♦) 3P *) 3P 15) 25A 3P PREP. SPACE 'TRN D 1000': 480V:208Y/120V 45kVA, NEMA 1 056) (0 8) (0 9) (/ FUT ) ( F T �) CRA- 08000 (ELEC ROOM) CON- 14081 (ELEC ROOM) r-1 1 1 F1 CRA- 04000 (DATA CENTER) \\ rieF' r r11 ERP- 04000 (DATA CENTER) CON- 07041 (DATA CENTER) L FUT. CRA- 06000 (DATA CENTER) CON- 06032 (DATA CENTER) CON- 08042 (DATA CENTER) L , 1 FUT. ERP- 06500 (DATA CENTER) FUT. CON- 09051 (DATA CENTER) FUT. CON- 10052 (DATA - CENTER) ( FUT. ) / 1 I% / \\\ // / r�1 1 r1 I r1 1 I 1--1 I F- 1 N FUT. ERP- 06000 (DATA CENTER) FUT. CON- 11061 (DATA CENTER) FUT. CON- 12062 (DATA CENTER) ONELINE DIAGRAM KEYED NOTES OGENERATOR NEUTRAL BONDING TO BE ACCOMPLISHED AT SWITCHBOARDS "GSB-1" AND "GSB-2". DISCONNECT NEUTRAL -GROUND BOND AT GENERATOR. O REFER TO DRAWING 1/E3.5 FOR CONTROL WIRING AT GENERATOR, ATS, GSB-1, GSB-2. O PROVIDE FULL SIZED FEEDER FROM JUNCTION BOX TO GENERATOR SWITCHBOARD. PROVIDE COMPRESSION TAPS. TYPICAL FOR ALL GENERATOR FEEDERS. O NEUTRAL/GROUND BOND BY MANUFACTURER. O PROVIDE 500MCM NEUTRAL/GROUND BOND. O REFER TO GROUNDING ONE LINE DIAGRAM SHEET El .2. 07 UNIT MOUNTED DISCONNECT PROVIDED WITH EQUIPMENT (TYPICAL FOR ALL CRAC'S AND ACCU'S UNLESS OTHERWISE NOTED). 08 30A/3P/15AF/N1 DISCONNECT PROVIDED AND INSTALLED BY E.C. O 30A/3P/15AF/N3R DISCONNECT PROVIDED AND INSTALLED BY E.C. 10 NEW UTILITY TRANSFORMER BY UTILITY COMPANY. CONTRACTOR TO PROVIDE TRANSFORMER PAD AND COORDINATE ALL REQUIREMENTS WITH THE UTILITY COMPANY. 1 1 NEW UTILITY UNDERGROUND PRIMARY FEEDER. PROVIDE (2) 6" PVC CONDUITS WITH CONCRETE ENCASEMENT AND PULLSTRINGS FROM NEW UTILITY SWITCH. COORDINATE ALL REQUIREMENTS WITH UTILITY COMPANY. 12 NEW UTILITY SERVICE LATERAL. - REVIEWED FOR, 1 COMPLIANCE WITH NFPA 70 - NEC MAR 14 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 0 2014 Gens Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 er 3 LLI co 0 1,1J 0 0) 00 to co 00 5 44( cf, F- ISSUES & REVISIONS No. Date Description 02/17/2014 ISSUE FOR PERMIT >XPIAE$._ E C SHEET E ELECTRICAL ONELINE DIAGRAM DRAWN: DGC REVIEWED: DGC PROJECT NO.: C1037.00 SHEET NO. Ei.1 SCALE: NOT TO SCALE PERMIT CENTER J PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRI I 1 EN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. N-G LINK WHERE — REQUIRED BY EQUIPMENT MANUFACTURER N-G LINK WHERE - REQUIRED BY EQUIPMENT MANUFACTURER N-G LINK WHERE REQUIRED BY EQUIPMENT MANUFACTURER N-G LINK WHERE REQUIRED BY EQUIPMENT MANUFACTURER 0 0 0 0 0 0•••••••••• • • • • • • • • • • 0 0 0 0••• • • • 0 0 o o•• • • 0 0 0 0 0 0• • 0 0 0 0 0 o_ O ° 0 o 0 7777777 g r' 'iT4?7 77 n 0 0 0 00 0 0 O 0 0. 0 0 0 0 0 U U U U 0✓ 'UPSA1000' NEUTRAL BUS GROUND BUS 'UPSB1000' NEUTRAL BUS GROUND BUS 'UPSC1000' NEUTRAL BUS L GROUND BUS 'UPSD1000' NEUTRAL BUS L GROUND BUS 'TRNC1000' (45kVA) 'TRND1000' (45kVA) 'PDUA1000' (300kVA) 'PDUB1000' (300kVA 'PDUC1000' (300kVA) 'PDUD1000' (300kVA 0 0 GROUNDING CONDUCTOR SCHEDULE MARK CONDUCTOR SIZE CONDUIT SIZE REMARKS G001 •500kCM 1-1/2" BARE TINNED, PROVIDE SCHEDULE 80 PV AT EXTERIOR OF BUILDING G002 500kCM NONE BARE TINNED G003 500kCM 1-1/2" INSULATED G004 #1/0 1" INSULATED G005 #6 3/4" INSULATED G006 #2 3/4" INSULATED G007 #4 NONE BARE TINNED G008 #4/0 1" INSULATED G009 #4/0 NONE INSULATED G010 #2/0 NONE INSULATED G011 #4 NONE INSULATED G012 #2/0 NONE BARE TINNED G013 #2 NONE INSULATED G014 #2/0 1" INSULATED NOTE: ALL CONDUCTORS ARE STRANDED COPPER WITH GREEN INSULATION UNLESS NOTED OTHERWISE. ALL CONDUCTORS LOCATED BENEATH THE RAISED FLOOR SHALL BE MARKED "FOR USE IN CABLE TRAYS" OR "FOR CT USE" PER NEC ART. 645.5(E)(6)b. PROVIDE SCHEDULE 40 PVC CONDUIT INTERIOR TO THE BUILDING AND SCHEDULE 80 EXTERIOR TO THE BUILDING. GROUNDING GENERAL NOTES 1. ALL BARS, LUGS, AND CONDUCTORS PROVIDED BY ELECTRICAL CONTRACTOR UNLESS NOTED OTHERWISE. 2. CONTRACTOR SHALL USE CADMIUM YELLOW, ZINC CHROMATE, OR STAINLESS STEEL BOLTS FOR CONNECTIONS TO GROUND BARS. 3. BEND RADIUS FOR GROUNDING CONDUCTORS SHALL BE AT LEAST 12 INCHES THRU #4/0 AND AT LEAST 24 INCHES FOR GROUNDING CONDUCTORS GREATER THAN #4/0. 4. PULL BOXES IN DEDICATED GROUNDING SYSTEM AS SHOWN ON THIS SHEET SHALL BE KEPT TO A MINIMUM AND SHALL BE NON-METALLIC OR ELECTRICALLY ISOLATED FROM ADJACENT CIRCUITS AND BUILDING COMPONENTS. 5. GROUND BAR CONDUCTORS SHALL NOT SHARE CONDUITS OR PULL BOXES WITH CONDUCTORS OR CABLES OF OTHER SYSTEMS. 6. ALL BARE GROUNDING CONDUCTORS SHALL BE TINNED. 7. STRANDED GROUNDING CONDUCTORS SHALL HAVE CLASS B STRANDING. 8. GROUNDING SYSTEM IMPEDENCE SHALL NOT EXCEED 5 OHM. CONTRACTOR SHALL ADD CHEMICAL GROUND ROD(S) AS NECESSARY TO ADHERE TO THIS REQUIREMENT. 9. ALL GROUNDING SHALL COMPLY WITH NEC ARTICLE 250 AS A MINIMUM UNLESS NOTED OTHERWISE. 10. ALL GROUNDS SHALL BE COPPER. • NO ALUMINUM SHALL BE PERMITTED. 11. ANY REQUIRED CONDUIT FOR GROUNDING SHALL BE PVC UNLESS NOTED OTHERWISE. NO METAL CHOKES SHALL BE ACCEPTABLE. SUPPORTS FOR GROUNDING CONDUITS SHALL UTILIZE NYLON BOLTS AND NON-METALLIC STRAPS TO PREVENT INSTALLATION OF CHOKE POINT IN GROUNDING SYSTEM. 12. ALL COMPRESSION LUGS SHALL BE TWO -HOLE LONG BARREL AND CRIMPED USING THE MANUFACTURER'S RECOMMENDED DIE AND CRIMPING TOOL GROUND LUGS SHALL BE SHRINK-WRAPPED AND LABELED WITH NONMETALLIC TAGS. 13. TOTAL GROUNDING CONDUCTOR BENDING RADIUS SHALL NOT EXCEED 90' AT EACH LOCATION. 14. GROUNDING CONDUCTORS SHALL BE CONTINUOUS BY GAUGE FOR ENTIRE LENGTH. SPLICES ARE NOT ALLOWED. 15. LEXAN COVER FOR ALL GROUND BARS SHALL BE LABELED WITH GROUND BAR NAME AND PANI DIVISIONS. 16. CONNECTIONS TO ALL BUS BARS SHALL BE IN PANI LOCATIONS AS INDICATED ON THIS SHEET. 17. PANI DESIGNATION LOCATIONS SHOWN ON THIS SHEET ARE SCHEMATIC IN NATURE. PROVIDE ADEQUATE MOUNTING HOLES AT EACH DESIGNATION L_ LI I LR FOR PRESENT AND FUTURE CONNECTIONS. EXOTHERMIC WELD TO NEW REBAR LOCATED IN NEW CONCRETE SLAB AT EQUIPMENT YARD PER NEC GENERATOR 'GEN01000' GENERATOR 'GEN02000' FUTURE GENERATOR 'GEN03000' , NOTE: BOND EACH .GENERATOR FUEL TANK TO REBAR IN CONCRETE SLAB UTILIZING "0002" CONDUCTOR. REFER TO GROUNDING PLAN FOR GROUND ROD AND TEST WELL LOCATIONS AND QUANTITIES N-G LINK G002 ABOVE GRADE In t') 0 0 0 0 0 to 0 0 0 BELOW GRADE. (NI UTILTY METERING CABINET NEUTRAL BUS L GROUND BUS N-G LINK N-G LINK 1 'GSB01000' NEUTRAL BUS GROUND BUS 'GSB02000' NEUTRAL BUS L GROUND BUS EXOTHERMIC WELD TO NEW REBAR LOCATED IN NEW CONCRETE SLAB AT EQUIPMENT YARD PER NEC EXOTHERMIC WELD TO NEW REBAR LOCATED IN NEW CONCRETE SLAB AT EQUIPMENT YARD PER NEC '-EXOTHERMIC WELD TO NEW REBAR LOCATED IN NEW CONCRETE SLAB AT EQUIPMENT YARD PER NEC VERIFY WITH OWNER QUANTITY OF RACKS TO BE INSTALLED IN EACH ROW. (TYPICAL) ROW 2 ROW 3 ROW 4 0 0 0 o O 0 �.1 4.4) WATER SERVICE ENTRANCE PIPING ABOVE GRADE BELOW GRADE —(G002)-- HH (G002)1 'MSG01000' MOUNTING: 8'-O" ABOVE FINISHED FLOOR LOCATION: ELECTRICAL ROOM PGP01000' MOUNTING: HORIZONTAL AT 8'-O" ABOVE RAISED FLOOR LOCATION: DATA CENTER A N I 0 0 O 0• O• 0 O 0••••• O••••♦ 0 O 0 0 O 77777 CABLE TRAY ABOVE RAISED FLOOR cL ABOVE RAISED FLOOR 0) rn 0 0 0) 0) 0 0 0 0 0 0 'EFG01000' MOUNTING: HORIZONTAL BELOW RAISED FLOOR LOCATION: DATA CENTER N. 0 ° 0 0 0 0• 0• o o•••••••• o o•••• •• ••• 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 r---! r--7 EQUIP. { EQUIP. 1 RACK 1 RACK L_1_J L_1_J l r J_ ( GO11) ( GO11 ) T-' �T_- z 0 0 000000 r---1 r----I EQUIP. I EQUIP. RACK 1 RACK J- -L ( G O 11) ( G 011 ) EQUIP. RACK L (GO11) T BELOW RAISED FLOOR P 'EFG02000' MOUNTING: HORIZONTAL BELOW RAISED FLOOR LOCATION: MMR1 A N I 0 0• o• 0 0 0 0 0 0 0 0 0 0 0 0O TYPICAL EQUIPMENT 7 RACK ON COMPUTER ROOM RAISED FLOOR. r---I EQUIP. RACK L (GO11) T� I EQUIP. I I EQUIP. I RACK RACK L _1_ J L — �J--- (GO11) (GO11) f ---1 (----1 EQUIP. I II EQUIP. RACK 1 1 RACK 1 L —1— J L J- L (G011) (G011) e' u r---! r---l. EQUIP. I I EQUIP. RACK 1 1 RACK L —�— J L —1— _L J_ (GO11) (GO11) GROUNDING ONE —LINE DIAGRAM NOT TO SCALE 0 -Di ROW 5 OUTE UNDER FLOOR DOWN RACK ROW TYPICAL FOR EACH ROW ROW 6 ROW 7 ROW 8 P 'RFG01000' P 'EFG03000' MOUNTING: HORIZONTAL BELOW RAISED FLOOR LOCATION: MMR2 A N I 0• 0 0 0 0 0 O 0• 0 0 0 0 0 00 MOUNTING: HORIZONTAL BELOW RAISED FLOOR LOCATION: DATA CENTER A N I 0 0• o• 0 o 0•• o•• 0 o 0 0 0 0 COMPUTER ROOM RAISED FLOOR GROUND GRID UL LISTED 'C' OR 'H' TAP COMPRESSION FITTING (P/P. WHERE SHOWN ON THIS SHEET). RPP EQUIPMENT ❑ TYP. REVIEWED FOR COMPLIANCE WITH NFPA 70 NEC MAR 14 2014 City of Tukwila BUILDING DIVISION RECEWED CITY OF TUKWILA 10400 Rodgers Road HOUSTON, TEXAS 77070 Ph: 281-374-8644 Fax: 281-374-8992 Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 O U D: EDCSEA01 UJ 0) 1 ISSUES & REVISIONS No. 1 Date Description 02/17/2014 ISSUE FOR PERMIT f C SHEETTITLE GROUNDING ONE -LINE DIAGRAM SHEET NO. FEB 2 0 am PERMIT CENTER DRAWN: WAM REVIEWED: RWB PROJECT NO.: C1047.00 E1.2 PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. EXISTING DOCK HIGH (-48") AREA NOT IN CONTRACT WAREHOUSE r, it :I - SOCK ELEVATION AT - 30" BELOW FIN, FL. a Tr EXIT I rr i 1 r- z E=nR, I JAN. 1 j (_.I I r -1 WOMEN I SINK { I(")1 1 / 1 1 L I I MEN ------ 1( ) Il ) I----- J vJ 1-v L- — -1 I I. 11 } \ (--J- -, r/ 1I I (l —J-._._--LI----L..--.JLi— �I IJ=-_7-ri------�---\ �I \ J ❑FFICE fT OFFICE ❑FFICE 1k r / T1 ❑FFICE ❑FFICE T P t f EQUIP. DGP. ❑FFICE L i / I 1----II II 11 - PRINT/C❑PY rr' 1 0 RECEPTI❑N EXITi ❑FFICE GEN, ❑FFICE TT II II ❑FFICE - P--- \ II / L'/ ❑FFICE JI 0 ELECTRICAL DEMOLITION PLAN SCALE. 1/8'.1-0' -I I- L I % DEMOLITION PLAN GENERAL NOTES 1. REFER TO SHEET E0.1 FOR ALL SYMBOLS ON THIS SHEET. 2. REFER TO SHEET E0.2 AND E0.3 FOR ELECTRICAL SPECIFICATIONS. 3. THE ELECTRICAL CONTRACTOR SHALL REMOVE FROM THE SITE ON A DAILY BASIS ALL DEMOLISHED EQUIPMENT AND: MATERIALS. IN NO CASE SHALL THE SITE BE USED FOR STORAGE OF DEMOLISHED MATERIALS. 4. ALL EXISTING DEVICES TO REMAIN SHALL HAVE THEIR EXISTING CIRCUITING EXTENDED TO EXISTING PANELS OR AS RECIRCUITED AS INDICATED ON SHEET E2.1. 5. FOR MECHANICAL EQUIPMENT TO BE DEMO'D, ELECTRICAL CONTRACTOR SHALL DISCONNECT POWER AND REMOVE FEEDER AND CONTROL CONDUIT BACK TO SOURCE. COORDINATE MECHANICAL EQUIPMENT DEMO WORK WITH MECHANICAL CONTRACTOR. 6. WHERE EQUIPMENT/MATERIALS ARE DESIGNATED TO BE RETURNED TO OWNER, THE CONTRACTOR SHALL VERIFY WITH THE OWNER IF THE OWNER WANTS TO RETAIN THE MATERIAL. IF NOT THE CONTRACTOR SHALL REMOVE THE MATERIAL FROM THE SITE. DEMOLITION PLAN KEYED NOTES 0 REMOVE ALL EXISTING LIGHTING, RECEPTACLES, FIRE ALARM DEVICES, ETC. IN THIS AREA AND RETURN TO BUILDING OWNER. FOR BUILDING STOCK. REMOVE ASSOCIATED CONDUIT AND WIRE. WHERE CONDUITS HAVE TO BE RELOCATED TO MAINTAIN CIRCUIT INTEGRITY :(EXTERIOR. LIGHTING) ALL NEW CONDUIT SHALL BE INSTALLED IN CORRIDOR AREAS. O REMOVE ALL EXISTING POWER DISTRIBUTION, PANELBOARDS, FEEDERS, TRANSFORMERS, ETC.. THE ELECTRICAL CONTRACTOR MAY RE -USE THE EXISTING FEEDERS AND EQUIPMENT AND EXTEND AS NECESSARY FOR TEMPORARY CONSTRUCTION POWER AND UPON COMPLETION OF CONSTRUCTION FINAL DEMOLITION TO OCCUR. KEYPLAN AREA OF WORK --REVIEWED PI� CE WT H COMPLIANCE 70 - NEC MAR 14 2014 City of Tukwila BUILDING DIVISION RCEIVED CITY 1 F TUKWILA FEB 2 0 2014 PERMIT CENTER Gensler Two Lincoln Centre, 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone:214/273-1559 No. 1 ISSUES & REVISIONS Date 02/17/2014 Description ISSUE FOR PERMIT C SHEET TITLE ELECTRICAL DEMOLITION PLAN DRAWN: WAM REVIEWED: RWB PROJECT NO.: C1047.00 SHEET NO. E2.D 1 PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. 1 A /1 r i' H r! r ��i !1 !/1 a ------------ ME_ 1- ‚' . . ._.- . . .. .. G‘-1OOO (500KWj CON14181 111 GEN02000 (500KW) 0• J .. 0 C0N13171 1 s SITE PLAN GENERAL NOTES 1. REFER TO SHEET E0.1 FOR ALL SYMBOLS ON THIS SHEET. 2. REFER TO SHEET E0.2 AND E0.3 FOR ELECTRICAL SPECIFICATIONS. 3. REFER TO SHEET E1.1 FOR ELECTRICAL ONE LINE DIAGRAM. 4. REFER TO SHEET E4.0 FOR FEEDER SCHEDULE. SITE PLAN KEYED NOTES 0 0 0 0 0 0 0 0 NEW UTILITY PAD MOUNTED TRANSFORMER. PROVIDE PAD, REQUIRED GROUNDING, SOIL WORK, ETC. AS REQUIRED BY THE UTILITY COMPANY. COORDINATE ALL REQUIREMENTS WITH THE UTILITY COMPANY. NEW UNDERGROUND FEEDER FROM TRANSFORMER. SECONDARY TO NEW METERING EQUIPMENT. REFER TO DETAIL 2/E3.3. NEW 2500A UTILITY METERING CABINET. INSTALL PER UTIUTY COMPANY REQUIREMENTS. NEW. UNDERGROUND SERVICE LATERAL REFER TO DETAIL 4/E3.3. NEW UNDERGROUND PRIMARY. PROVIDE (2) 6" CONDUITS WITH PULLSTRINGS PER UTILITY COMPANY REQUIREMENTS. WHERE CONDUITS ARE INSTALLED IN TRENCHES AND NOT BORED PROVIDE RED CONCRETE ENCASEMENT. PROVIDE SPARE. (7) 3-1/2" CONDUITS STUBBED OUT FROM BREAKER COMPARTMENT TO 24" BEYOND EDGE OF PAD. EXISTING UTILITY COMPANY METERING ROOM. REFER TO SHEETS E2.D, E2.1, E2.2, E2.3 AND E2.4 FOR WORK IN THIS AREA. FCU03000 FRONT FRONT FRONT mcpottkkfth,sEco, .... ® .. e.. ELECTRICAL SITE PLAN SCALEI 1/16'-1-0' . . M . . - .. MI IP .. NMI .. SIMINNIII.■ . REVIEWED .FOR COMPLIANCE WITH NFPA70-NEC MAR 14 2014 City of Tukwila BUILDING DIVISION Gensler Two Lincoln Centre 5420 LB.! Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 No. ISSUES & REVISIONS Date Description 02/17/2014 ISSUE FOR PERMIT SEAL. SHEETTIME ELECTRICAL SITE PLAN RECEIVED CITY OF TUKWILA FEB 2 0 2014 PERMIT CENTER DRAWN: WAM REVIEWED: RWB PROJECT NO.: C1047.00 SEETNQ E2.0 PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. '^` - \ D / n LCPC1 000-9 LCPC1 000-34,36 2#6 #10&. 3/4"C. ' FCUO3OOO | ' U : � / | / ' / | ' ! ' GEN0]DOU� | K� ' `-�- '\ ' ' �*0 ` ^. . ' a�R� 14ffi_ 0 0 th 10�-2 \�^�mur� 31AOU � GENO2OOD A5Q8KVv �c � LgCpC1000-10 »P,� ' (l GR OOO-14 EXFO1OOU / wp, mn | ' / WDPC1UOO-J �00171 | / i N LCPD1000-15 LCPD1000-17 N1 MDPA1O00- WDPB10U0 1 LCPD1000-18 � oc o��_*/mm ��� - 8ATl�BATT JPS81U0C-A8CB1UO{ 11 WDPD1OU0-% FRONT FRdNT LCPC1000-15 FRONT NN �xu�x m�m�,mw�ww�cm�m��wu��mmmmwmm* �w�mmu �,wm�u��we�mmm�*m�m �mew�*emmx��m�� � BATTK8ATT FRONT FRONTUCpC/^mkkADPC �OOO'vvv1000 FRONT WSBO1 ' 100. ! 100. 1 100. 100. 100. 100. 100.| 100.1 1Nl 4 5 0 7 8 9 10/11i 12 || ' 200 200 200 200 200 200 2V0 200 200 200 200 1 2/ 3 4 S n 7 O 8 10 11 . 12 PDUD1UOO-2 ' ELECTRICAL �� N � 0�= � = N 0��N0 m �� N ���� 0~� N=��0�~� � �. PLAN N 1 LCPD1000-24,26 #1OQ, U UJPD1000-1�,5 � LCPD1000-13 NV n LCPC1OOO-7 LCPC3000-2426 3146. /CUl \ 00( LCPD1 L LCpC10O0-1 / POWER PLAN GENERAL 1. REFER TO SH[ET8l1 FOR ALL SYMBOLS ON THIS SHEET. 2. REFER TO SHEETS EO2 AND EO.3 FOR ELECTRICAL SPECIFICATIONS. I SEE ONE UN[ DIAGRAMS AND`FEEDER SCHEDULES FOR FEEDER SIZES AND EQUIPMENT SIZES NOT INDICATED ON THIS PLAN. 4. INSTALLATION OF ALL UNDERFLOOR UL LISTED POWER WHIPS IN THE RAISED FLOOR AREAS SHALL INCLUDE THE WHIP AND ITS ASSOCIATED CIRCUIT BREAKER IN THE INDICATED RPP PANEL. 5. 3E[ MECHANICAL PLANS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OF HVAC EQUIPMENT. C UNLESS 6. ALL SINGLE PHASE BRANCH CIRCUITS ARE (3) #12, 3/4 IDENTIFIED OTHERWISE ON THIS PLAN, ELECTRICAL ONE LINE DIAGRAMS, OR AS REQUIRED BY SHE[TED.1 TO.BE INCREASED DUE TO VOLTAGE DROP PER N.E.C. ` NEUTRAL CONDUCTORS SHALL NOT -BE SHARED. T REFER TO 1/E3.2 FOR MOUNTING HEIGHT OF ' ' 8. POWER REQUIREMENTS TO RACK MOUNTED COMPUTER HARDWARE EQUIPMENT ARE wnuErnnEu AT /no TIME WHEN OWNER SELECTS EQUIPMENT, ENGINEER NCH CIRCUIT DISTRIBUTION REQUIREMENTS TO CONTRACTOR SHALL SUBMIT BRA FOR INSTALLATION. POWER WILL BE DISTRIBUTED VIA LIQUIDTIGHT CONDUIT (UL LISTED POWER WHIPS) UNDER RAISED FLOOR FROM REMOTE POWER PANELS (RPP) SHOWN IN DATA CENTER. ENGINEER WILL CONFIRM LOAD DOES NOT EXCEED THE CAPACITY OF THE RPP'S. AND UPSTREAM ELECTRICAL DISTRIBUTION. S. REFER TO SHEET [2.0 FOR ADDITIONAL CONDUIT ROUTING REQUIREMENTS.' WARNING SIGNS AND NFPA 704 HAZARD IDENTIFICATION SIGNS SHALL BE INSTALLED TO CLEARLY IDENTIFY HAZARDS PER LSB STANDARD 13 SECTION 5.7. SIGNS SHALL HAVE RED COLORED LETTERING ON A WHITE BACKGROUND, STATING: 'NO SMOKING, WELDING, OR OPEN FLAMES WITHIN 25 FEET' SIGNS SHALL BE PROVIDED ON THE SIDES OF TANKS OR SECURITY FENCING IN THE DIRECTION OF FIRE DEPARTMENT APPROACH. WARNING SIGNS AND NFPA 704 HAZARD SIGNS SHALL HAVE LETTERING AT LEAST 3 INCHES IN HEIGHT OF WEATHER -RESISTIVE MATERIALS. 11. PROVIDE 3.5" CONCRETE HOUSEKEEPING PADSFOR INTERIOR EQUIPMENT AS SHOWN. PAD SHALL BE MINIMUM OF 3" LARGER THANEQUIPMENT ON ALL SIDES, 12. PROVIDE CANBUS CONDUIT AND CABLING BETWEEN PER DETAIL 3/E3.5. �� Pv������� PLAN KEYED NOTES PROVIDE CONNECTION TDGENERATOR WATER JACKET HEATER. /2)J6, #8 G. IN " CONDUIT ROUTED WITH GENERATOR FEEDER. CIRCUIT OVER -SIZED FOR MORE THAN THREE CURRENT CARRYING CONDUCTORS IN ONE CONDUIT. PROVIDE CONNECTION TO GENERATOR BATTERY CHARGER. kA KV 1-1/4" CONDUIT ROUTED WITH GENERATOR FEEDER. CIRCUIT OVER -SIZED FOR MORE THAN THREE CURRENT CARRYING CONDUCTORS IN ONE CONDUIT. PROVIDE CONNECTION TO CONDENSING, FIELD VERIFY EXACT TERMINATION LOCATION. REFER TO E1.1 FOR CIRCUITING REQUIREMENTS AND E1.4 FOR UNDERGROUND CONDUIT ROUTING. PROVIDE CONNECTION TO REFRIGERANT PUMP, FIELD VERIFY EXACT TERMINATION LOCATION. REFER TO E1.1 FOR CIRCUITING REQUIREMENTS. PROVIDE CONNECTION FIELD VERIFY B0{T TERMINATION LOCATION. REFER TO E1.1 FOR CIRCUITING REQUIREMENTS. UNIT HAS INTEGRAL MOUNTED DISCONNECT SWITCH INCLUDED AS OPTION WITH UNIT. PROVIDE INDUSTRIAL GRADE RETRACTABLE POWER CORD REEL KH INDUSTRIES REEO FF POWER CORD REEL MODEL NUMBER RTB83L-WW-J12K. 50 FOOT / SJ CORD, 125V 20A WITH SINGLE 5-20R RECEPTACLE.RECEPTACLE.PROVIDE OPTIONAL 345 DEGREE PIVOT BASE, MODEL NUMBER RT8F-PV8. MOUNT REEL AT CEILING HEIGHT, SUPPORTED FROM STRUCTURE ABOVE. PROVIDE ADD11IONAL SAFETY CHAIN FROM STRUCTURE ABOVE TO REEL BASE. ONCE INSTALLED THERE SMALL BE NO NOTICEABLE MOVEMENT /N EITHER THE YERDCLE OR HORIZONTAL DIRECTIONS. FIELD VERIFY EXACT LOCATION WITH BCB PRIOR TO INSTALLATION. PROVIDE CONNECTION TO RPP. FIELD VERIFY EXACT TERMINATION LOCATION. REFER TO ONE LINE DIAGRAM FOR CIRCUITING REQUIREMENTS. PROVIDE INTERFACE TO LOCKOUT DURING TRANSFER TO GENERATOR POWER. REFER TO DETAIL 1/E3.5. PROVIDE CONNECTION TO WATER HEATER. EP0 SYSTEM PANEL PROVIDED BY FA CONTRACTOR INSTALLED BY E.C. REFER TO DETAIL 1/E3.4 FOR ADDITIONAL INFORMATION. EPO BREAKGLASS BUTTON. COORDINATE EXACT LOCATION WITH ADJACENT DEVICES NOT SHOWN ON THIS PLAN. REFER TO DETAIL 1/E3.4 FOR ADDITIONAL INFORMATION. POWER CONNECTION T0 EQUIPMENT. SEE 2/E3.5FOR POWER FIELD VERIFY EXACT LOCATION WITH BCEIPRIOR 0ROUGH-IN. FIRE RATED PLYWOOD MOUNTED ON WALL FOR PHONE BOARD. FIELD VERIFY EXACT LOCATION OF QUAD ON PHONE BOARD WITH BCEI PRIOR TO INSTALL PULLBOX FOR OUTSIDE ABER, PROVIDED AND INSTALLED. BY. OTHERS. FAN CONTROLLED BY.00CUPANCY SENSOR IN RESTROUM. EXTEND CIRCUIT TO LIGHTING IN RESTRO0WL REFER TO E2.2 FOR MORE INFORMATION. MOTORIZED DAMPER BY MECH. CONTRACTOR. PROVIDE 120V POWER TO NEAREST NON UPS RECEPTACLE {]nOUT). PROVD[ RELAY TO INTERLOCK WITH FCU CONTROLS 3O DAMPER OPENS WHEN PCU IS IN OPERATION. RELAY TO HAVE 24V CONTROL COIL AND CONTACTS RATED AT 120V, 10A. 2- VIEWED FOR COMPLIANCE WITH NF MAR 14 2014 BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 ~ 2014 PERMIT CENTER � ^� � Two Lincoln Centre ' _ S/ite11MO ` �Dallas, |X/5240 `21 1559 � ^� / J%M���� MVISIn=�NS 'Date Descripdon 1 O2/17/2O14 ISSUE FOR PERMIT 0Bmn= ELECTRICAL POWERPLAN �� � DRAWN VAM REVIEWED: RWB 'PROJECT NO.: C1047.00 SHMNO. PROPRIETARY' NOT FOR DSCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, �C � � . �� (14) 11 LCPD1000-10 (13) /CLO3 H8 H8E LCPC1000-2 CL03 \ LCPD1000-2 (15, CEN01000 (600K'W) C0N 14181 GEN02000 (600KW) LCPC1000-10 H8E NL LCPC1000-6 LCPD1000-6 C0N 13171 LCPD1000-12 100. 100. 6 7 100. 100. 8 9 LCPC1000-8 200. 1 200. 2 200. 3 200. 200. 200. 200. 200. 200. 200. 200. 200. 4 5 6 7 8 9 10 11 12 300. 300. 300. 300. 300. 300. 300. 300. 300. 300. 300. 300. 5 6 7 8 9 10 11 1 2 3 4 12 400.1400 S12 00.1400. 400. 3 14 5 400. 400. 400. 6 7 1 8 i s 500.1500. 500. 500. 500. 500. 500.11500. 500.1500. 500.1500. 500. i 500. 560.1500. . 1 2 3 4 5 6 7 8 9 1 10 111 1 12 13 14 15 16 I I 1 i ; 1 700. 700. 2 3„ (16) 600.1600. 700. 1700. 415 800.1800. 600.1600. 6 1 7 800.1800. 800. 1800. 819 600 160C. „„LCPD1000-8 600. 16C0. 600. 14 t 700.17C0. 14 • ELECTRICAL LIGHTING PLAN SCALE' 1/8'-1'-0' LCPD10 1 CLO2 CL02 9) JE CL02"\ A B CD LIGHTING PLAN GENERAL NOTES 1. REFER TO SHEET E0.1 FOR ALL SYMBOLS ON THIS SHEET. 2. REFER TO SHEETS. E0.2 AND E0.3 FOR ELECTRICAL SPECIFICATIONS. 3. REFER TO SHEET E4.2 FOR LIGHTING FIXTURE SCHEDULE. 4. PROVIDE (2) #10, (1) #10G IN 3/4" CONDUIT FOR ALL LIGHTING CIRCUITS. 5. COORDINATE INSTALLATION OF LIGHTING FIXTURES WITH OTHER TRADES. 6. OCCUPANCY SENSOR WIRING INDICATED ON PLANS IS INDICATIVE OF OCCUPANCY SENSORS, POWER PACKS AND LIGHTING CIRCUITS INSTALLED AS A SYSTEM. REFER TO MANUFACTURER'S DATA FOR EXACT WIRING REQUIREMENTS. LIGHTING PLAN KEYED NOTES O LIGHTING FIXTURES G TO BE CONTROLLED, VIA REMOTE MOUNTED PHOTOCELL. HELD COORDINATE LOCATION OF PHOTOCELL TO AVOID CYCLING OF FIXTURE DUE TO ADJACENT LIGHTING. 0 FIXTURE TO REMAIN UNSWITCHED FOR EGRESS/NIGHT LIGHTING. TYPICAL 0 OCCUPANCY SENSOR TYPE "OS1 ", LEVITON MODEL NO. OSWLR-IoW. TYPICAL. LOWERCASE LEI I ER ADJACENT TO DEVICE AND LIGHT FIXTURE DENOTES SWITCHING GROUP SENSOR CONTROLS. POWER PACK TYPE "OSP", LEVITON MODEL NO. OSP20-RDH 0 POWER PACK TYPE "OSA', LEVITON MODEL NO. OSA20-ROO ADD A RELAY. LIGHTING REQUIRED AT DOORS TO MEET 5.0 FOOTCANDLES ® DOOR AND 2.0 FOOTCANDLES WITHIN 15' RADIUS OF EXIT. CONTRACTOR SHALL .SUBMIT FOOTCANDLE CALCULATIONS TO CONFIRM PRIOR TO INSTALLATION OF FIXTURE. FIXTURE SHALL ALSO BE A FULL CUTOFF DESIGN, DARK SKY COMPLIANT. TYPICAL OF 2 TYPE JE FIXTURES. 0 FIXTURE SHALL BE A FULL CUTOFF DESIGN, DARK SKY COMPLIANT. TYPICAL OF 3 TYPE G FIXTURES. 1 ut KEYPLAN AREA OF WORK REVIEWED FOR COMPLIANCE WITH NFPA70 - NEC MAR 14 2014 City of Tukwila BUILDING DIVISION RECEI ED YOFTU .t FEB 2 A PERMIT CENTER Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240. Phone: 214/273-1559 No. 1 Q w w w V, ISSUES 8c REVISIONS Date Description 00 co C!) O co CV J 02/17/2014 DRAWN: WAM REVIEWED: RWB PROJECT NO.: C1047.00 ISSUE FOR PERMIT SHEET NO. E2.2 PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. FCU04000 ( 14 ) ) FCU03000 ( 15 ) ( 17 ) QENO 000 • if (600KW) • CON14181 CEN02000 • (600KW) LL CD I C) CD z r_ CLO3 \ 0 Lc CON131-71 .• MI, ' ' IPA • SIM • M 111 .!!!: ' 0' • !I': N1E_, Pit IA- : NV Psi.' -AU Pik WE-_: r r I CA1000 FRONT PSB1 001 FRONT BCB100 FRONT FRONT FRONT BCC1 00 FRONT FRONT PSD1 00 FRONT FRONT 01000 •AIL ,• Mir MI. ft us 0 • MIL ' r•'. 0. ill II • • F-mil : CD CL X 0 LIJ Cs.1 C:) CD CD CD U7 fq Of CD C:7 CL CD cc' 41 re) CD HOT AISLE 1131 1001. 100. es 100. 100. 100. 100. 00. 100. 100. 100. 21 3 5 6 7 8 I 9 10 11 12' COLD AISLE HOT AISLE 1500E15001 00.1500.1500. I 1 L_ __L I _L_ COLD AISLE 400d400.i400.1400.1400.1400 HOT AISLE 500. 1500.1500. 1500. I load 500.1500. i5oo. 500.1 5.19. 1500. . • c.) co 600. 1600. q00. l0. 600.1600. 600.1600.1600. 1600.1600. , I ; 4 i51671R:q _1_ __L_ __L _L._ _L_ HU1 AISLE 77- 700. O. 7100. 1700. 1700. 700. 1700. 1700. 1700. 1700. 1700. _L __L_ _L COLD AISLE L_ ._L _L_ 600.1600400.16 0.1600.1 19 13 1 Ar1516 ri _L. _L_ _j 1 L ELECTRICAL GROUNDING PLAN SCALE. 1/8•-1-0' 7-Ns (19 ) CLO2 EXF02000----111 El FCU1 000 / C1_02 \ \- I LAV- 1 i\. FCU 2000 ms, mi at ma in•in it at iv tr"VaNINIMMIIIMINIIII11111111111111""' CIjA09000 0,01Pmc01s CO1 e ri 8 1 I CLO2 /-ct.02N GROUNDING PLAN GENERAL NOTES 1. FOR GROUNDING ONE-UNE DIAGRAM, REFER TO SHEET E1.2. 2. REFER TO SHEET E3.1 FOR GROUNDING DETAILS. 3. NOT ALL CONDUCTORS INDICATED ON THIS PLAN. REFER TO• 1/El .2 FOR MORE INFORMATION. CONDUCTOR SIZES INDICATED ON 1/E1.2. 4. SEE 1/El 2 FOR CONDUCTOR TERMINATION LOCATIONS AT EACH GROUND BAR. • CONDUCTORS SHALL BE TERMINATED AT GROUND BARS PER 1/E1.2. 5. COORDINATE EXACT LOCATION OF GROUND CONDUCTOR TIE IN EQUIPMENT WITH EQUIPMENT SUBMITTALS. PROVIDE LUGS AS REQUIRED. GROUNDING PLAN KEYED NOTES 0 0 0 0 a (DI so GROUND TEST WELL LOCATION. COORDINATE LOCATION WITH EXISTING AND NEW UNDERGROUND CONDUITS/UTILITIES. PROVIDE COMPRESSION LUG BOLTED TO FUEL TANK FOR GROUNDING CONNECTION. TYPICAL. PROVIDE EXOTHERMIC CONNECTION TO REBAR LOCATED IN• CONCRETE SLAB. PROVIDE TEN FEET OF COILED CONDUCTOR FOR CONNECTION TO FUTURE EQUIPMENT. PROVIDE 1 6x1 6x8 N3R PVC BOX FOR PROTECTION OF CONDUCTOR. TYPICAL 1 0'-0" x 3/4" COPPER CLAD STAINLESS STEEL GROUND ROD. TYPICAL GROUNDING CONNECTION TO RAISED FLOOR PEDESTAL, 'TYPICAL. RAISED FLOOR GROUNDING CONDUCTOR, TYPICAL. CONNECTION TO HVAC EQUIPMENT. PROVIDE BONDING STRAPS AROUND SUPPLY AND RETURN AIR FLEXIBLE CONNECTIONS. TYPICAL. CONNECTION TO METAL DOOR FRAME. TYPICAL. GROUND BAR "MSG01000" GROUND BAR "PGP01 000" GROUND BAR "EFG01 000" GROUND BAR "RFG01000" GROUND BAR "EFG02000" GROUND BAR "EFG03000" COORDINATE LOCATION WITH EXISTING AND NEW UNDERGROUND CONDUITS/UTILITIES. CONNECTION TO BUILDING STEEL. TYPICAL. CONNECTION TO RPP. TYPICAL. AREA OF WORK REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC MAR' 1 4 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 0 2014 • PERM;T CENTER r • Gens Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 er• J ISSUES & REVISIONS No. 1 Date Description 02/17/2014 ISSUE FOR PERMIT ;011E; ) ELECTRICAL GROUNDING PLAN SHEET TITLE • DRAWN: WAM REVIEWED: RWB PROJECT NO.: C1047.00 SHEET NO. E2.3 KEYPLAN 1 • PROPRIETARY: NOT FOR D SCLOSURE OR USE WM-IOUT THE WRITTEN t CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. •• 1 GEN01000 (600KW) 1 •0 1 CON 14181 v GEN02000 (6001<w) I.1 0.: FCU04000 EXF01000 FCU03000 1 BFP PA-2 PA-1 FD-2- 1 1 1 1 1 ,/ / i CD a CO 0 O •i / t 0 CC 0 w CCo w o / , / Q O O I CC 0 U � rr 1 7 / / /' / CD a- o CC w CD . CD / ) ' / L / 1 1 i-HON 1 rHONI FRONT FRONT ij3CA1000 BATT. FRONT FRONT FRONT FRONT 1-H`0N 1 MOPD CPD TP.N 1 000 n(' '' JPSA100C BATT, BATT. BATT. ABCC100Q1PSC100C JPSB100C'4BCB1OOC BATT. BATT. BA: .I BATT. JPSD100CNBCD1000 FRONT FROM T L.CPC F`NCMIDPC 10001000 1000 FRONT FRONT FRONT FRONT FRONT sto FRONT PDU. 1000 PDUE 1000 PDU 1000 DU 9 1000 n_ CC FRONT MSBO 100' 01000 0_ LLI LL CC 100. I 10Q. 1 0. 100. 4 • 0. 1 100. 100. 100. 11 1 12 LJ 1 ._1 200. 1 200. 2 2 0. 200. 4 2 00. 6 200. 7 2 J 0. 6 200. 9 200. 10 200. 11 200. 12 CO IUD w c CC EXF02000 FCU1000 0 C.0• o • LO CC • I U I/ / 4 ,/ 1 3 / /1 // 1 L_-Jt'__�__J NlO1 JB-1 11 r1 LAV-1 CRA1.0000 CRA09000 DCP0 E 1 C01 SECO1 000--`0`-'-000 000 p o 0 0 ELECTRICAL CONDUIT PLAN SCALE' 1/8•-1'-0• CONDUIT ROUTING PLAN GENERAL NOTES 1. REFER TO SHEET E0.1 FOR GENERAL NOTES AND SYMBOL LEGEND. 2. THIS DRAWING'S INTENDED USE IS TO ASSIST IN THE ROUTING OF UNDERGROUND AND INTERIOR TO THE BUILDING CONDUITS AND SETS MINIMUM REQUIREMENTS FOR FUTURE CONDUITS. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMING THE EXACT CONDUIT QUANTITIES AND REQUIREMENTS. 3. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL SEISMIC BRACING AND DESIGN, WHERE REQUIRED BY LOCAL AUTHORITIES. 4. ALL FEEDERS ARE TO BE SUPPORTED FROM THE FLOOR. SUPPORTING FROM THE CEILING/ROOF IS NOT ALLOWED WITHOUT PRIOR APPROVAL BY STRUCTURAL ENGINEER. CONDUIT ROUTING PLAN KEYED NOTES 0 0 0 FEEDER CONDUITS TO RPP'S ROUTED UNDER RAISED FLOOR. CONTRACTOR TO KEEP CONDUITS AS CLOSE TO BOTTOM OF SLAB AS POSSIBLE. PROVIDE OFFSETS/SADLES AS NECESSARY. UNDERGROUND FEEDER/CONTROLS CONDUITS FROM GENERATORS TO BUILDING. STUB CONDUITS UP AT EXTERIOR OF BUILDING AND ROUTE OVERHEAD TO INTERIOR. UNDERGROUND SERVICE LATERAL. CUT AND PATCH SLAB TO ORIGINAL SPECIFICATION. I LI REVIEWED FOR COMPLIANCE�� NF MAR 14 2014 City o Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 0 2014 PERMIT CENTER Gens Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 er ISSUES & REVISIONS No. Date Description 1 02/17/2014 ISSUE FOR PERMIT SHEET TITLE ELECTRICAL CONDUIT PLAN DRAWN: WAM REVIEWED: RWB PROJECT NO.: C1047.00 SHEET NO. E2.4 KEYPLAN PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. CON20130 �2 LCPC1000-38,40,42 3#10, #10G., 3/4"C. CON01011 CON02012 CON03021 LCPC1000-19 CON04022 CON05031 CON06032 CON 9140 LCPD1000-38,40,42 3#10, #10G., 3/4"C. CON15120 CON16110 40 ■ WP, MDPA1000-2 02 MDPB1000-2 0 MDPC1000-5 0 CON10042 CON11061 CON12062 ELECTRICAL ROOF PLAN SCALE. 1/8•-1'-0• LCPC1000-28,30,32 3#10, #10G., 3/4"C. LCPD1000-28,30,32 3#10, #10G., 3/4"C. LCPD1000-21 CON17010 0 MDPA1000-4 O 2 CON1809© MDPB1000-4 0 2 17 ROOF PLAN GENERAL NOTES 1. REFER TO SHEET E0.1 FOR ALL SYMBOLS ON THIS SHEET. 2. REFER TO SHEETS E0.2 AND E0.3 FOR ELECTRICAL SPECIFICATIONS. 3. SEE ONE LINE DIAGRAMS AND FEEDER SCHEDULES FOR FEEDER SIZES AND EQUIPMENT SIZES NOT INDICATED ON THIS PLAN. 4. SEE MECHANICAL PLANS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OF HVAC EQUIPMENT. 5. ALL SINGLE PHASE BRANCH CIRCUITS ARE (3) #12, 3/4" C UNLESS IDENTIFIED OTHERWISE ON THIS PLAN, ELECTRICAL ONE LINE DIAGRAMS, OR AS REQUIRED BY SHEET E0.1 TO BE. INCREASED DUE TO VOLTAGE DROP PER N.E.C. NEUTRAL CONDUCTORS SHALL NOT BE SHARED. 6. FIELD VERIFY EXACT LOCATION OF ALL MECHANICAL EQUIPMENT TERMINATIONS. 7. PROVIDE CONTROLS/MONITORING WIRING FOR MECHANICAL EQUIPMENT. COORDINATE EXACT REQUIREMENTS WITH DETAILS AND MECHANICAL CONTRACTOR. 1 ROOF PLAN KEYED NOTES O REFER TO ONE LINE DIAGRAM FOR SIZING. O ROUTE POWER AND CONTROLS WIRING ALONGSIDE REFRIGERANT PIPING. UTILIZE SAME ROOF PENETRATION. 03 PROVIDE NEW 30/3/NF/N3R HEAVY DUTY DISCONNECT SWITCH. 04 PROVIDE NEW WEATHERPROOF, DUPLEX, GFI RECEPTACLE. SUPPORT INDEPENDENT OF MECHANICAL EQUIPMENT. 05 MECHANICAL PIPING ROOF PENETRATION. �l KEYPLAN AREA OF WORK I REVIEWED FOR'H COMPL,IAN NFPA?'©�NEc MAR 14 2014 City o Tukwila BUILDING DIVISION RECEIVED CITY OF TUIKWILA FEB 2 0 2014 PERMIT CENTER Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 CD D: EDCSEAO1 W 1-- CD co co_ en Es • co 92 .J N M I -- ISSUES & REVISIONS No. Date Description 02/17/2014 ISSUE FOR PERMIT r SHEETTITLE ELECTRICAL ROOF PLAN DRAWN: WAM REVIEWED: RWB PROJECT NO.: C1047.00 SHEETNO PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. 1 is BLOCKING (FOR GYP. BD. WALL ONLY) S/S NUT S/S I3ELLEVILLE WASHER S/S SELLEVILLE WASHER ti POLYESTER INSULATER (TYP.) 5/8" HARDWARE AND LOCKWASHERS (TYP.) LEXAN COVER WITH NAME LABEL AND PANI DESIGNATIONS GROUND BAR MOUNTING BRACKET GYP. OR CMU WALL FINISHED FLOOR GROUND BAR MOUNTING NOT TO SCALE CN 3/4" --- 0 0 0 O 0 0 0 0 0 O 0 0 O 0 0 0• O 0 0 0 0 0 0 0 1 1/2" (TYP.) 9/16" 0 (TYP.) AS REQUIRED 2" (TYP.) NOTES: 1. ALL HOLES ARE COUNTERSUNK 1/16". 2. BAR STOCK IS 1/2" THICK, 98% CONDUCTIVE COPPER. 3. SILVER-PLATED COPPER BUS BAR. 4. REFER TO 3/E6.1 FOR MOUNTING DETAIL. 5. REFER TO 1/E6.1 FOR GROUND LUG DETAIL. 6. DETAIL IS SIMILAR FOR ALL GROUND BUSSES. 7. PROVIDE BUS EQUAL TO LIGHTNING MASTER "BUSMASTER" SERIES "B" PATTERN. 8. BUS LEXAN COVER SHALL BE CLEARLY LABELED WITH NAME CORRESPONDING TO THOSE INDICATED ON 1/E1.2. 9. BUS LEXAN COVER SHALL BE CLEARLY LABELED LEFT -TO -RIGHT WITH "P", "A", "N", "I" DESIGNATIONS WITH A VERTICAL LINE BETWEEN EACH DESIGNATION. ALLOW FOR ENOUGH MOUNTING HOLES AT EACH DESIGNATION FOR ALL CURRENT CONNECTIONS WITH ALLOWANCES FOR FUTURE CONNECTIONS. REFER TO 1 /E1.1. GROUND BUS DETAIL NOT TO SCALE MAXIMUM 1/8" GROUNDING LUG Ir l 11 COPPER BUS S/S BOLT (1 OF 2) 11/16" 0 (TYP. OF 2) —1/4" (MIN.) CLEAR HEAT SHRINK GROUNDING CONDUCTOR LABEL INDICATING FAR END TERMINATION "DO NOT DISCONNECT" TAG ON ALL GROUND BAR INTERCONNECTS. PROVIDE NYLON STRAP TO ATTACH TAG TO CONDUCTOR. NOTES: 1. ALL HARDWARE SHALL BE 18-8 STAINLESS STEEL INCLUDING BELLEVILLES. COAT ALL SURFACES WITH KOPR-SHIELD BEFORE MATING. 2. FOR GROUND BOND TO STEEL ONLY: INSERT A DRAGON TOOTH WASHER BETWEEN LUG AND STEEL COAT ALL SURFACES WITH KOPR-SHIELD. GROUNDING LUG DETAIL NOT TO SCALE EXOTHERMIC CONNECTION (CADWELD) FLOOR STRINGER MAINTAIN 12" BENDING RADIUS #4 AWG STRANDED COPPER CONDUCTOR TO INTERNAL PEDESTAL N'N__ PANDUIT #GPQC. SIZED TO ACCOMODATE PEDESTAL DIAMETER. PEDESTAL ttt FLOOR STRINGER #4 AWG STRANDED COPPER it CONDUCTOR TO NEXT PEDESTAL PANDUIT #GPQC SIZED TO ACCOMODATE PEDESTAL DIAMETER. INTERNAL PEDESTAL GROUNDING DETAIL NOT TO SCALE FLOOR STRINGER —\1/4 #4 AWG TO FLOOR STRINGER FLOOR STRINGER #4 AWG, STRANDED COPPER CONDUCTOR TO INTERNAL PEDESTAL MAINTAIN 12" BENDING RADIUS PERIMETER #2/0 AWG STRANDED COPPER CONDUCTOR PANDUIT #GPQC SIZED TO ACCOMODATE PEDESTAL DIAMETER. PEDESTAL #4 AWG STRANDED COPPER -' CONDUCTOR TO NEXT PEDESTAL REMOVE PAINT AROUND PERIMETER AT GROUNDING CONNECTION POINT. PEDESTAL BURNDY YAV RING LUG WITH THRU BOLT, LOCKWASHER, AND NUT. PERIMETER PEDESTAL GROUNDING DETAIL NOT TO SCALE GROUNDING CONDUCTOR (REFER TO DRAWINGS FOR SIZES) STRUCTURAL STEEL MEMBER PRIOR TO CONNECTION, SCRAPE AWAY ALL PAINT AND/OR GALVANIZING THEN REAPPLY AS NECESSARY AFTER CONNECTION IS COMPLETE TYP. GROUNDING CONNECTION TO STEEL NOT TO SCALE #4 AWG STRANDED COPPER CONDUCTOR TO INTERNAL PEDESTAL PERIMETER #2/O AWG STRANDED COPPER CONDUCTOR PANDUIT #GPQC SIZED TO ACCOMODATE PEDESTAL DIAMETER. REMOVE PAINT AROUND PERIMETER AT GROUNDING CONNECTION POINT. PEDESTAL QUAZITE COVER #PG1118HAOO WITH "GROUND ELECTRODE" EMBOSSED ON COVER FINISHED GRADE QUAZITE BOX #PG1118BB12 PROVIDE SIX INCHES OF #57 OR #67 GRAVEL FILL AT BOTTOM OF TEST WELL COPPERCLAD GROUND ROD (PROVIDE SECTIONAL THREADED ROD AT TESTWELL LOCATIONS TO ACHIEVE 12" BELOW GRADE ROD ELEVATION.) GROUNDING TEST NOT TO SCALE SINGLE HOLE COMPRESSION LUG BRONZE U-BOLT 3/8" MIN. CONCRETE RING AROUND BOX FINISHED SMOOTH ?�— REMOVABLE CONNECTION #4/0 JUMPER CONNECTED TO GROUND LOOP. CADWELD CONNECTION GROUND LOOP COPPERCLAD GROUND ROD WELL/HANDHOLE DETAIL BRONZE HEX NUT (2) WITH LOCKWASHER BRONZE CROSS BAR BRONZE HEX NUT (2) WITH LOCKWASHER THIS DETAIL APPLIES TO ALL METALLIC - PLUMBING AND HVAC PIPING AS WELL AS SPRINKLER PIPING. DO NOT PROVIDE GROUNDING CONNECTIONS AT GAS PIPING. TYP. PIPING GROUNDING CLAMP NOT TO SCALE FOR ALL #2/0 TO #2/O CONNECTORS PROVIDE BURNDY C-TAP CRIMP CONNECTOR. ATTACH PEDESTAL TO #2/0 AWG PERIMETER WIRE AND #4 AWG SUPPLEMENTARY WIRE AT EACH INTERSECTION OF WIRE. LOCATE ALL GROUNDING WIRE AND GROUNDING CLAMPS UNDER RAISED FLOOR. GROUND EVERY FOURTH PEDESTAL OF RAISED FLOOR IN BOTH DIRECTIONS ONLY BETWEEN ROWS OF EQUIPMENT. GROUNDING CONDUCTORS ARE NOT ALLOWED UNDER EQUIPMENT ROWS PARALLEL TO THE ROWS. CONNECT TO THE MAIN STRINGER WITH A #4 COPPER WIRE AT ALL PERIMETER CONNECTIONS. RAISED FLOOR GROUNDING DETAIL NOT TO SCALE -01'1 DETAIL NOTES: 1. PROVIDE THE GROUNDING CONDUCTORS, CONNECTORSN AND CONNECTIONS TO THE RAISED FLOOR IN ACCORDANCE WITH THE RAISED FLOOR GROUNDING DETAIL AS SHOWN. 2. PROVIDE A #2/0 AWG STRANDED COPPER CONDUCTOR FOR THE PERIMETER RING AROUND THE RAISED FLOOR. PROVIDE A SUPPLEMENTARY SYSTEM OF #4 AWG STRANDED COPPER CONDUCTORS INSIDE THE PERIMETER IN BOTH DIRECTIONS AT EVERY 6TH PEDESTAL MAXIMUM AS SHOWN ON GROUNDING PLAN. CONNECT SUPPLEMENTARY #4 AWG TO EVERY 4TH PEDESTAL ALONG ITS LENGTH. AT EACH INTERFACE BETWEEN THE #2/0 PERIMETER AND #4 SUPPLEMENTARY CONDUCTORS (WHERE THEY CROSS), CONNECT BOTH CONDUCTORS TO A RAISED FLOOR PEDESTAL VIA A BURNDY TYPE GP-G1 CONNECTOR. 3. AT ALL PERIMETER CONNECTOR LOCATIONS, PROVIDE A #4 AWG STRANDED COPPER CONDUCTOR BETWEEN THE CONNECTOR AND THE MAIN (CONTINUOUS) STRINGER OF THE RAISED FLOOR SYSTEM. ATTACH TO THE MAIN STRINGER WITH A BOLT WITH LOCKING WASHER AND NUT, DRILLED AND INSERTED THROUGH THE SIDE OF THE STRINGER. 4. BOND ALL FLOOR MOUNTED CRAC UNIT STANDS TO THE #2/0 PERIMETER CONDUCTOR OR #4 CROSS CONDUCTOR VIA A #4 AWG STRANDED COPPER CONDUCTOR BURNDY C-TAP CRIMP OR APPROVED EQUAL. 5. INSTALL ALL GROUNDING CONDUCTORS AND CONNECTORS UNDER RAISED FLOOR (TO THE EXTENT THAT THIS IS POSSIBLE). ALL GROUNDING CONDUCTORS BELOW RAISED FLOOR SHALL BE RAISED AS HIGH AS POSSIBLE OFF OF CONCRETE FLOOR. 6. REMOVE ALL PAINT AROUND PERIMETER OF PEDESTAL AT THE POINT WHERE GROUND CONNECTOR AND CONDUCTORS ARE ATTACHED TO PEDESTAL 7. BOND ALL UNDERFLOOR METALLIC CONDUITS, CABLE TRAY, OR OTHER CONDUCTING STRUCTURES TO THE RAISED FLOOR GROUNDING SYSTEM AT THEIR POINTS OF ENTRY INTO THE RAISED FLOOR AREA VIA A #4 AWG STRANDED COPPER CONDUCTOR BURNDY C-TAP CRIMP OR APPROVED EQUAL REVIEWED FOR COMPLIANCE WITH NFPA 74 - NEC MAR 14 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 0 2014 10400 Rodgers Road HOUSTON, TEXAS 77070 Ph: 281-374-8644 Fax: 281-374-8992 Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 L1J U 0 LLJ 0 w Cn 00 CD 00 0) N J ISSUES & REVISIONS No. Date Description 02/17/2014 ISSUE FOR PERMIT i.024114: r EXPiar ot:. -oir, t4 C SHEET TITLE ELECTRICAL DETAILS SHEET NO. PERMIT CENTER DRAWN: WAM REVIEWED: RWB PROJECT NO.: C1047.00 E3.1 1 PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. System No. W-La 059 F Ratings —1 and 2 Hr (See item 1) TRating —0Hr 1. 1 OR 2 HR FIRE -RATED GYPSUM BOARD/STUD WALL ASSEMBLY. 2. CHANNEL SHAPED STEEL STUDS, MIN 3-1/2 IN. WIDE AND SPACED MAX 24 IN. OC. ADDITIONAL FRAMING MEMBERS SHALL BE INSTALLED IN STUD CAVITY CONTAINING THROUGH PENETRANTS TO FORM A RECTANGULAR BOX AROUND THE PENETRANT. 3. GYPSUM BOARD* - 5/8 IN. THICK, MAX AREA OF OPENING IS 765 SQ IN. WITH MAX DIMENSION OF 40 IN. WIDE. 4. CONDUITS - MAX OF TEN CONDUITS TO BE INSTALLED WITHIN THE OPENING. A MAX OF SIX CONDUITS SHALL BE GREATER THAN 2 IN. THE MAX SPACE BETWEEN CONDUITS AND BOARD CUTOUT AND OTHER CONDUITS IS 1 INCH. 4. CABLES - MAX OF ONE 4 IN. (OR SMALLER) DIAM TIGHTLY BUNDLED CABLES INSTALLED WITHIN THE OPENING AND RIGIDLY SUPPORTED ON BOTH SURFACES OF WALL. 5. FIRESTOP DEVICE* - BOARD - MIN 1 IN. THICK BOARD TO BE INSTALLED ON EACH SIDE OF WALL WITH MIN 1 IN. OVERLAP ONTO WALL AND TIGHTLY BUTTED SEAMS. BOARD TO BE ATTACHED TO FRAMING MEMBERS AROUND ENTIRE PERIMETER USING 2-5/8 IN. LONG SELF -DRILLING TYPE S STEEL SCREWS WITH 1-1/4 IN. OD STEEL FENDER WASHERS AT EACH CORNER AND SPACED MAXIMUM 8 IN. OC IN BETWEEN. 6. FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 1 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS BETWEEN THE METALLIC THROUGH PENETRANTS (ITEM 2) AND THE PERIPHERY OF THE BOARD. FILL MATERIAL INSTALLED FLUSH WITH BOTH SURFACES OF WALL. 7. FILL, VOID OR CAVITY MATERIAL* - SEALANT - MIN 1 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS BETWEEN THE CABLE BUNDLE (ITEM 3) AND THE PERIPHERY OF THE BOARD. FILL MATERIAL INSTALLED FLUSH WITH BOTH SURFACES OF WALL. CONDUIT WALL PENETRATION NOT TO SCALE 1/2" ALLTHREAD ROD TO STRUCTURE OVERHEAD. REFER TO SPECIFICATIONS FOR ACCEPTABLE SUPPORT METHODS TRAPEZES ARE TO BE SPACED MAXIMUM 5'-0" APART. AFTER INSTALLATION OF CONDUITS AND CONDUCTORS TAPEZES SHALL SHOW NO VISIBLE DEFLECTION CONDUIT CLAMPS PROVIDE SINGLE THREADED NUT AND WASHER ON TOP OF MATED SURFACES AND TWO NUTS AND WASHER ON BOTTOM OF MATED SURFACES WHERE CONDUITS CANNOT BE SUPPORTED FROM STRUCTURE ABOVE PROVIDE STANTION POLES FOR SUPPORT OF TRAPEZES. SCHEDULED CONDUIT PROVIDE TWO 1-1/2" SECTIONS v I STRUT MATED BACK TO BACK MAXIMUM FIVE EXPOSED THREADS WITH ENDS FILED SMOOTH AND ROUNDED BRANCH DEVICE TO LOAD— IG 480V PRIMARY EQUIPMENT GROUNDING CONDUCTOR 208Y/120V SECONDARY -DRY-TYPE TRANSFORMER GROUND CONNECTION POINT AT TRANSFORMER GROUNDING ELECTRODE CONDUCTOR NEUT. MAIN BRKR IG • • • NEUTRAL CONDUCTOR STRUCTURAL STEEL OR AREA GROUND BUS EQUIPMENT GROUNDING CONDUCTOR INSULATED NEUTRAL TERMINAL —120/208V PANELBOARD GROUND BUS ISOLATED GROUND BONDING JUMPER ISOLATED GROUND BUS H - BLACK, RED OR BLUE N - WHITE G - GREEN IG - GREEN/ WITH YELLOW STRIPE TRANSFORMER CONNECTIONS NOT TO SCALE .0111 .75" .75" 4.5" 3/8" 3/8" GREEN COLOR PRINT ON BOTH SIDES NOTE: NAMEPLATE SHALL. HANG BELOW LIGHTS APPROX. 3". USE SMALL LINK CHAIN. "BACK TO BACK" OUTLET BOXES ARE TO BE INSTALLED ON OPPOSITE SIDES OF FRAMING MEMBERS TO LIMIT SOUND TRANSMISSION. WHERE THIS IS NOT POSSIBLE PROVIDE MINIMUM 6" CLEAR SPACE BETWEEN BOXES. 00 6" MIN -› 00 OUTLET BOX (TYPICAL) WALL PARTITION OUTLET COVER (TYPICAL) PARTITION FRAMING MEMBER OUTLET BOX INSTALLATION NOT TO SCALE PROVIDE PHENOLIC LABELS AT EACH PIECE OF ELECTRICAL DISTRIBUTION EQUIPMENT (AND ASSOCIATED BRANCH FEEDERS AND DISCONNECTING MEANS INCLUDING UNIT MOUNTED DISCONNECTING MEANS. EQUIPMENT UPSTREAM FROM ATS EQUIPMENT SHALL BE WHITE LABELS WITH BLACK 1/4" LETTERING. ALL ATS AND EQUIPMENT DOWNSTREAM SHALL BE AS FOLLOWS: A DISTRIBUTION: RED LABELS WITH WHITE LETTERING B DISTRIBUTION: BLUE LABELS WITH WHITE LETTERING C DISTRIBUTION: ORANGE LABELS WITH WHITE. LETTERING D DISTRIBUTION: PURPLE LABELS WITH WHITE LETTERING PROVIDE INFORMATION IN THE FORMAT INDICATED. PANEL "EDC*****MDPA1 000" FED FROM "EDC*****MDSA1 000" 480V, 400A '*' IN PANEL NAME REFERENCES EDGECONNEX SITE ID NUMBER. REFER TO EDGECONNEX SITE ID IN SHEET TITLEBLOCK. TYPICAL PANEL/GEAR LABELING DETAIL NOT TO SCALE AUDIBLE, VISUAL, COMBINATION AUDIBLE/VISUAL INDICATING APPLIANCE 80" AFF OR 6" BELOW CEILING, WHICHEVER IS LOWER WALL MOUNTED INFORMATION SYSTEM OUTLET 18" 18" 54" 6" 42" 0 REVIEWED FOR COMPLIANCE WITH NFPA70-NEC MAR 14 2014 City of Tukwila BUILDING DIVISION INFORMATION SYSTEM OUTLET MOUNT VERTICALLY DUPLEX RECEPTACLES MOUNT VERTICALLY LIGHT SWITCH MULTI -GANG SWITCHES SHALL EXTEND AWAY FROM THE DOOR INTERCOM SYSTEM VOLUME CONTROL. REFER TO SPECIAL SYSTEMS PLANS FOR LOCATIONS. DOUBLE ACTION PULL STATION EPO SWITCHES RECE!V°ED CITY OF TUKWILA FEB 2 0 2014 10400 Rodgers Road HOUSTON, TEXAS 77070 Ph: 281-374-8644 Fax: 281-374-8992 Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 J O 1 ISSUES & REVISIONS No. Date Description 1 02/17/2014 ISSUE FOR PERMIT C Is 04 tie • 14:._ I SHEET TITLE ELECTRICAL DETAILS TRAPEZE FOR CONDUIT SUPPORT NOT TO SCALE UNDERFLOOR BAR LOCATION INDICATOR NOT TO SCALE ELECTRICAL DEVICE MOUNTING DETAIL NOT TO SCALE PERMIT CENTER DRAWN: WAM REVIEWED: ' RWB PROJECT NO.: C1047.00 SHEET NO. E3.2 PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. 120V ATSA100 N.O. N.O. CONTACTS WHICH CLOSE WHEN. TRANSFER SWITCH IS IN THE "EMERGENCY" POSITION. LOCATED AT ATS TERMINAL STRIP. ATSB100 N.O. ATSC100{ N.O. HI ATSD1000 N.O. *II* L T R1 /CONTROL TRANSFORMER PROVIDED BY CONTRACTOR, PROVIDE .PRI.. AND SEC. FUSING. 480x240/24V, 50VA. LOCATE INTERIOR OF CRAC UNIT. CONNECT TO 480V SOURCE ON LOAD SIDE OF UNIT MOUNTED DISCONNECT. SPARE R31 T R3. L ? LR5) R5 82 83. CRA01000 TERMINAL BLOCK RELAY PROVIDED BY CONTRACTOR, 120V COIL, PROVIDE MINUMUM TWO CONTACTS RATED AT 10A, ONE N.O., ONE N.C., NEMA 1 ENCLOSURE. LOCATE INTERIOR OF CRAC UNIT. 82 83 SPARE � A A) 1821 FUTURE CRA05000 — i 1 831 TERMINAL BLOCK L-J CRA03000 TERMINAL BLOCK R54. J SPARE DETAIL NOTES: 1. FIELD WIRING CONSISTS OF #12 AWG CONTROL WIRING IN 3/4 CONDUIT. 2. CONDUCTOR TERMINATIONS AT CRAC'S TO BE PERFORMED BY OTHERS. 4- L R21 T R2 z I,R4) I..Y-Y..Y_� L SPARE R4 SPARE L L Z 6) R61 T L R61 AAyA) 82 83 r 1821 1831 1 a 1 L---J L 82 83 r SPARE CRA02000 TERMINAL BLOCK FUTURE CRA04000 TERMINAL BLOCK FUTURE CRA06000 TERMINAL BLOCK CRA UNIT REHEAT/HUMIDIFICATION SHUTDOWN NOT TO SCALE TO 20/3 BRKR IN RPPO4D03 TO 20/3 BRKR IN PNL LCPD1000 4#12, 1#12G., 3/4"C. L21-20R RECEPTACLE CORD PROVIDED WITH SWITCH RACK MOUNTED TRANSFER SWITCH, 120/208V, 3P, OFCI APC MODEL NO. AP7701 CORD PROVIDED WITH SWITCH NOTE: RACK TRANSFER SWITCHES REQUIRE A & B INPUT SOURCES TO BE IN PHASE WITH EACH OTHER. JUNCTION BOX TO 20/3 BRKR IN RPPO4A01 ti 0 2#12, 1#12G., 2#12, 1#12G., 1/2"C. 1/2"C. 0 4#12, 1#12G., o TO REMOTE DRY 1/2"C TO REMOTE DRY CONTACT BOX CONTACT BOX (DCP01000) IN (DCP02000) IN ISS ROOM I r l ELEC ROOM I GEIST PDU IN RACK, OFCI 4#12, 1 # 12G., 1/2"C. 3P, 4W RECEPTACLE TO MATCH GEIST PDU GEIST PDU IN RACK, OFCI REDUNDANT POWER TRANSFER SWITCH - ISS ROOM PROVIDE MINIMUM 3'-0" COVER OR AS REQUIRED BY LOCAL CODES WHICHEVER IS GREATER. DEPTH IS TO BE COORDINATED WITH OTHER UTILITIES. ..\\\" \,&// / /s) N/././ / / /2/ >//\;s\>// ////// ////> DETAIL NOTES: 1. COORDINATE WITH LOCAL UTILITY COMPANY STANDARDS AND REQUIREMENTS. FOIL -BACKED MARKER TAPE 16" MAX OC., MIN. ONE AT EACH SIDE ELECTRICAL DUCT BANK WITH RED CONCRETE ENCASEMENT. PROVIDE MINIMUM 3" OF CONCRETE COVER ALL FOUR SIDES. #3 STIRRUP AT 5'-0" O.C. CONDUIT SPACER 8'-O" O.C. #5 CONTINUOUS REBAR 3" (TYP) FOR CONDUIT LARGER THAN 2 2" (TYP) FOR CONDUIT 2" AND SMALLER SERVICE LATERAL DUCTBANK NOT TO SCALE ROOF PENETRATION HOOD ITB-50 ITB-49 I [TB-70/71/2301 CON -TB-70/71 /230I L ITB-49I ERP CRA ITB-50' TB-49 D B-70/71 /230 I CON L ROOF MECH CORRIDOR RAISED FLOOR MECH CORRIDOR CONCRETE FLOOR CANBUS WIRING LEGEND O (1) PLENUM RATED TSP CABLE EQUAL TO BELDEN #89207. 0 (3) #14 WITH 600V INSULATION. KEYED NOTES 0 CONNECT TO INDICATED TERMINALS. O INSTALL ALL INDICATED WIRING IN (1) 1-1/4" EMT CONDUIT. PROVIDE FLEXIBLE CONNECTION AT UNIT. 0 INSTALL ALL INDICATED WIRING IN (1) 1-1/4" GRS CONDUIT WHERE EXPOSED ON ROOF. PROVIDE FLEXIBLE CONNECTION AT UNIT. SUPPORT CONDUIT ON ROOF WITH DURABLOCK SUPPORTS SO CONDUIT IS MORE THAN 3-1/2" ABOVE ROOF LEVEL OINSTALL ALL INDICATED WIRING IN (1) 1" EMT CONDUIT. PROVIDE FLEXIBLE CONNECTION AT UNIT: CRA/ERP/CON CANBUS REQUIREMENTS NOT TO SCALE FEMALE THREADED COUPLING SET FLUSH WITH FACE OF CONCRETE FACE OF WALL SURFACE OR TOP OF SLAB SURFACE Q 4 '4 . •44 •a• ,44 •• • - •• PROVIDE MINIMUM 3'-0" COVER OR AS REQUIRED BY LOCAL CODES WHICHEVER IS GREATER. DEPTH IS TO BE COORDINATED WITH OTHER UTILITIES. NOTES: 1. DUCTBANK REPRESENTS ONLY ONE FEEDER. CONTRACTOR MAY INSTALL ADJACENT 1600A FEEDERS INTO THE SAME OVERALL CONCRETE ENCASED DUCTBANK IF DESIRED. 2. CONTRACTOR SHALL VERIFY EXACT QUANTITY OF ALL CONDUITS AND INCLUDE IN DUCTBANK. 4 • a Q 4 • 4d 4 FOIL -BACKED MARKER TAPE 16" MAX OC., ONE AT EACH SIDE 3" (TYP) FOR CONDUIT LARGER THAN 2" 2" (TYP) FOR CONDUIT 2" AND SMALLER 2500A DUCTBANK NOT TO SCALE FLUSH THREADED PLUG. AT WALLS, DRILL & BOLT THROUGH FORM TO HOLD COUPLING IN PLACE DURING CONCRETE POUR: •4. • a, a 4 • 4 4a 4 • °d. 4• '� PVC COATED GRC ELBOW OR RISER EXTENSION UNLESS OTHERWISE SPECIFIED ADAPTER OR COUPLING PVC CONDUIT OR AS NOTED OR SPECIFIED CONDUIT STUB AT CONCRETE SURFACE NOT TO SCALE 2'BRASS CAP; ENGRAVE INDICATING FUNCTION AND FINAL DESTINATION. iii0‘,/ \I/i \III MARKER TAPE FINISHED GRADE 2" GALVANIZED STEEL PIPE — CONDUIT STUB -OUT WITH CAP. RECORD ALL ACTUAL STUB -OUT LOCATIONS "AS -BUILT". 0 PROVIDE CONDUIT MARKER ELECTRICAL DUCTBANK WITH RED CONCRETE ENCASEMENT. PROVIDE MINIMUM 3" OF CONCRETE COVER ALL FOUR SIDES. #3 STIRRUP AT 5 FT. O.C. CONDUIT SPACER 8'0" O.C. #5 CONTINUOUS REBAR TO MSB01000 LI EXTERIOR WALL DISTANCE AS INDICATED ON PLANS, 3'-O" MINIMUM. IN NO CASE SHALL CONDUITS BE TERMINATED BELOW CONCRETE PAVEMENT, SIDEWALKS, ETC. UNDERGROUND SPARE CONDUIT STUB -OUT NOT TO SCALE STUB CONDUITS UP FLUSH WITH FLOOR FINISH. MAINTAIN TWO INCHES OF CLEARANCE BETWEEN BACK EDGE OF CONDUITS AND INTERIOR WALL FINISH. MAINTAIN TWO INCHES OF CLEARANCE BETWEEN CONDUITS. INTERIOR WALL FINISH REVIEWED .FOR COMPLIANCE C�H NEC MAR 14 2014 CI o 'Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA 10400 Rodgers Road HOUSTON, TEXAS 77070. Ph: 281-374-8644 Fax: 281-374-8992 Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 No. ISSUES &REVISIONS Date Description 1 02/17/2014 ISSUE FOR PERMIT C SHEET TITLE ELECTRICAL DETAILS FEB 2 0 2014 PERMIT CENTER J DRAWN: WAM REVIEWED: RWB PROJECT NO.: C1047.00 SHBETNQ E3.3 PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRI I I EN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. 00 ti NEW AUTOMATIC TRANSFER SWITCH "ATSD1 000" EPO SYSTEM COMPONENTS E.P.O. STATION SWITCH(ES) SHALL BE A SQUARE D MODEL .#9001 K15 GLASS BREAK OPERATOR #9001KA1 CONTACT BLOCK. THE E.P.O. SWITCH SHALL BE MOUNTED TO MATCH OTHER DEVICES HEIGHTS. PROVIDE RED LAMACOID NAMEPLATE 2"Wx4"H WITH 3/8" HIGH WHITE LETTERING (2 LINES) LABELED "EMERGENCY POWER OFF". THERE SHALL BE (1) EPO SWITCHES AT EACH LOCATION. THE EPO SWITCH(ES) SHALL OPERATE SUCH THAT WHEN THE GLASS DISK IS BROKEN THE OPERATOR IS NO LONGER HELD IN A DEPRESSED POSITION. THE CONTACTS CLOSE, OPERATING THE EPO SYSTEM WHEN BOTH SWITCHES AT A STATION HAVE BEEN ACTIVATED. PROVIDE FIVE REPLACEMENT GLASS DISKS. THE ENCLOSURE SHALL BE A FIKE EPSMS SINGLE DOOR, WALL MOUNT ENCLOSURE WITH HINGED DOOR, LOCK KIT ACCESSORY, NEMA 1 SURFACE MOUNTED: PROVIDE RED LAMACOID NAMEPLATE WITH 3/8" HIGH WHITE LETTERING (2 LINES) LABELED "EP001000". EPO SYSTEM OPERATION THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIALS REQUIRED TO FURNISH A COMPLETE. AND OPERATIONAL EPO SYSTEM. EPO SWITCHES SHALL BE INTERFACED WITH ALL CRAC UNITS, RPPS, AND THE FIRE ALARM PANEL THE FOLLOWING ARE CONTROL FUNCTIONS FOR THE SPACE: 1. THE SYSTEM SHALL PROVIDE CONTROL TO SHUTDOWN ALL DATA CENTER CRAC UNITS AND CLOSE ALL FIRE/SMOKE DAMPERS IN THE EVENT A STAGE TWO ALARM RELAY IS ACTIVATED (TWO SMOKE DETECTORS IN ALARM, VIA FIRE ALARM CONTROL PANEL). 2. THE SYSTEM SHALL PROVIDE CONTROL TO SHUTDOWN ALL DATA CENTER CRAC UNITS, ALL UPSS, IN THE EVENT TWO EPO SWITCHES ARE ACTIVATED. 3. THE SYSTEM SHALL PROVIDE CONTROL TO SHUT DOWN ALL DATA CENTER CRAC UNITS, ALL UPSS IN THE DATA CENTER IN THE EVENT THE WATER RELEASE RELAY IS ACTIVATED. CONTRACTOR SHALL BE RESPONSIBLE FOR INTERFACING WITH THE BUILDING FIRE ALARM SYSTEM. 4. THE SYSTEM SHALL BE BUILT WITH ENOUGH CAPACITY TO ACCOMMODATE ALL FUTURE UPSS, CRACS UNITS, ETC. AS INDICATED ON EPO WIRING DIAGRAM THIS SHEET. 5. REFER TO THE EPO WIRING DIAGRAM THIS SHEET FOR ADDITIONAL INFORMATION. CONTROL POWER FOR THE EPO SYSTEM SHALL BE DERIVED FROM A NORMAL POWER SOURCE. UPS POWER SHALL NOT BE USED. 6. ALL EPO BREAKGLASS COMPONENTS AND/OR ANY FIRE ALARM SIGNAL FUNCTIONS MUST BE RESTORED TO NORMAL BEFORE EPO RESET BUTTON CAN RESTORE THE EPO SYSTEM TO NORMAL CONDITION. 00 NEW AUTOMATIC TRANSFER SWITCH "ATSC 1000" 0 NEW AUTOMATIC TRANSFER SWITCH "ATS81000" (M023) (M022) 0 00 NEW AUTOMATIC TRANSFER SWITCH "ATSA1 000" M025) (M024) --(M026) (M021 E.P.0 ACTIVATION INPUTS REMOTE MONITORING (TO BMS PANEL IN ISS ROOM) EPO STATION #1 AT SERVICE DISCONNECT ROOM14 EPO STATION #1 DATA CENTER 114 _#14 114 EPO STATION #2 DATA CENTER 114 H�H _114 FIRE ALARM CONTROL PANEL MASTER CONTROL PANEL PLCO1000 0 0 0 U U \ n 0 N N 0 0 0 GENERATOR SWBDS 'GSB01 000' 0 N O O O GENERATOR SWBDS 'GSB02000' 0 BMS 114 114 EPO ACTIVATION ALARM 114 114 SYSTEM IN BYPASS ALARM f--I F6-414 M002) 114 EP001000 KEY SWITCH NORMAO. SYSTEM RESEr/LAMP TEST KEY SWITCH OVERRIDE MAINTENANCE OVERRIDE KEY SWITCH I>I L - J 0 0 2ND ALARM E.P.O. NOT USED ACTIVATION ACTIVATION (AC EPO) (AC & UPS EPO) SILENCE EPO SYSTEM. DIAGRAM NOT TO SCALE OPT. STANDBY 550kW/687.5KVA GENERATOR GEN01000 480Y/277V, 30, 4W, 0.80PF 1000/3 100% (M004 (Moo3) (M006 M005 (M007) (Mo08)-- (Mol o M009 (M012 (Mo13 MO1 1 (M015) (M014) M020 0 OPT. STANDBY 550kW/687.5KVA GENERATOR GEN02000 480Y/277V, 30, 4W, 0.80PF 1000/3 ) 100% M017 #14 TO UPSA1000 #14 #14 TO UPSB1000 #14 #14 TO UPSC1000 #14 #14 TO UPSD1000 #14 #14 CRA01000 TERMINALS #14 ( 91 )----s- •-•-----{ 92 38 ). (37) #14 (37) FUTURE CRA02000 TERMINALS ( 91 }--$- f-----e----( 92 )----( 381. #14 #14 CRA03000 TERMINALS 91 } - ♦- -� --{ 92 }-----( 38 #14 CRA04000 TERMINALS 91 )---•-- -f---{ 92 )-----{ 38 (37) (37) FUTURE CRA05000 TERMINALS ( 37 1 FUT. OPT. STANDBY 550kW/687.5KVA GENERATOR GEN03000 480Y/277V, 30, 4W, 0.80PF r L. (M018\ 550kW , .. I 1000/3 "` 100% M / KEYED NOTES 0 GENERATOR FEEDER. REFER TO FEEDER SCHEDULE ON SHEETS E4.1 AND E4.2 FOR MORE INFORMATION. 0 EXTEND TO THE ELECTRICAL ROOM. REFER TO SHEET E2.1 FOR LOCATION. 0 3 FIELD COORDINATE EXACT TERMINATION LOCATION. 4o FOR FUTURE GENERATORS, STUB CONDUITS INTO A 1 NEMA 1 PULLBOX INSIDE ELECTRICAL ROOM. REFER TO SHEETS E2.0 AND E2.1 FOR MORE INFORMATION. o REFER TO XYZ FOR BMS LOCATION. (M016 ITT FUT. OPT. STANDBY 550kW/687.5KVA GENERATOR GEN04000 480Y/277V, 30, 4W, 0.80PF r (Mo 19)- L 0 550kW ; a 4...r.,.. 4� 1000/3 " -�J 100% 'r- T y_ f I 0 GENERATOR CONTROLS WIRING REQUIREMENTS SCALE: NTS FUTURE CRAO6000 TERMINALS ---( 38 E.P.0 ACTIVATION OUTPUTS STAGE 2 ONLY OUTPUTS REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC MAR 14 2014 City of -Tukwila BUILDING DIVISION GENERATOR SYSTEM CONTROL 11 SCHEDULE MARK FROM CONTROL WIRING. SPECIFICATIONS' CONDUIT SIZE NUMBER OF SETS NOTES .M001 GEN01000 PLCO1000 (2)CAT 5E (6E) 1-1/4" M002- GEN01000 PLC 000. (12) #14, (4) #12' 1 114" M003 GEN02000 PLCO'1(lOQ (2) CAT 5E (6E) 1 1f4" 1„5 M004 GEN02000 PLC 000 (12):#i4, (4) #12`. 1-1/4" 5: FUT.'GEN0300o PLC01QI3Q -PU STRING ONLY M006 FUT. GEN03000 P LCOI000 PULLSTRING ONLY 1f4". '1- MQOI FUT. GENO4.000 P LCU1000' PULL:STRIN'G ONLY 1-1/4". 2,.3 FUT : GENN04O(Q P C01,000 P€itLSTRING ONLY 1-114": 2, - M009 :GEN01000 JUNCTION BOX .47 1,5 MOO9A JUN.CTION�.BOX GSB0200.0. (2-)#14-:THH I 1" Ia1OC9B JUNCTION: BOX GSB01 000. (2) #1411*IN 5' 010 '..GEN02000 JUNCTION BOX (4) #14 T HN -1/4" I,. 5 IA • JUNCTIONI SOX GSB0200.0 4 0 JUNCTION BOX GSBO1000_ (2)#14 : HN 1,.5 .FUT. GENo3000 JUNCTION BOX PULLSTRING ONLY 1 1/4+ .'2, .3 MO11A JUNCTIOAI 8OX GSBQ200F PULL:STRING ONL' 2, JUNCTION: BOX GSB41:I00 PULLSTRING ONLY 2 3 M012: FUT. GEN040.00 JUNCTION BOX PULL.STRtNG ONLY • 14147 2,.3 JUNCTION BOX GSBO200 PUL MIRING. ONLY 2,.3 M0'12B JUNCTION;BOX B010Q PULLSTI INq LY 2,3 Ni.01'.3 GEN '}1004 ELECTRICAL ROOM PULLS ONLY 14E4: 27. 3 M014. GENG2000 ELECTRICAL ROOM PULL NCONLY 1, {14" 2, .3 14015 'FUT.. 'GEN 000 ELECTRICAL R031I Pu S. LY 1-114-" 2,3 FUT:.: GEN04010 CTRLCAL ROAM. PU.L.LSTRING G3N Y 14,": 2, M07 GENE GEN02000 (1.6) # 14 TfH_H$ I 14F3 1,..5 018: :GEN02000 R.T. GEN:0300a PUL.LSTRING ONLY 1-114". 2 FUT. GEM 000 FT GENQ4000 'PULLS I' IN.G ONLY 1 €/4" 020 FUT; 'GEN.040.Q.0 GENQ1000. PULLS" 'Y tf. 2 M02 PLCQ1a00 JUNCTION BOX (20) #14 THHN` 4". M02:IA JLINICTION BOX GSBO2000 (10) #14 TH ,2, 3 M0218 JUNCTION BOX GSBD'I00( 14 TIjHN 1,5 2 ATSD100# PLCOI00€ : (..12) #14 TI HHN: Hu:0 3' ATS.0100O PLCQ1 14" M024 ATSB.1000 PLC 00 (12): # 4'TFIHN: .M025. ATSA1O00 PLCOIOoa (12) #14 THHIN; M€}26' PLG01.I30e BMS (2) CAT E. 6E). 4" NOTE'S 1) ALL WIRING SHALL BE CONFIRMED WITH :GENERATOR SUPPLIER PRIOR T .INSTALLATIOi ., 2) PROVIDE PERMANENT CONDUIE CAPS, .TEMPORARY CONDUIT CAPS NOT AI+L€ 1E1 3) EXTEND CONDUIT T€D INTERIOR PULLBoX FOR READY EXTENSION TO?FUTURE EQUIPMENT REFE 4) FIELD VERIFY EXACT TERMINATION:LOCATION AT'EITHER.GSBO:1000 QR GSB02000.. 5) PROVIDE 600V INSULATION. TO SHE€T 2: 0 AND E2.1., RECEIVED CITY OF TUKWILA FEB 2 0 2014 10400 Rodgers Road HOUSTON, TEXAS 77070 Ph: 281-374-8644 Fax: 281-374-8992 1 Gensler Two Lincoln Centre 5420.LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 C$) 4, ISSUES &REVISIONS No. Date Description 1 02/17/2014 ISSUE FOR PERMIT i y ,4 ELECTRICAL DETAILS DRAWN: WAM REVIEWED: RWB PROJECT NO.: C1047.00 SHEETNO. E3.4 PERMIT CENTER 4, PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. J BOTTOM OF STRUCTURE VARIES BOTTOM OF STRUCTURE VARIES BOTTOM OF LAY -IN CEILING +12'-0" BOTTOM OF LAY -IN CEILING +10'-6" TOP OF RACK +7'-6" TOP OF RAISED FLOOR +0' 0" CONCRETE FLOOR SLAB -2'-6" ROOF \/\1\ VVVVIr IFV7 V 1r NT L LIGHT LIGHT LIGHT LIGHT i S FIXTURE FIXTURE FIXTURE FIXTURE LIGHT FIXTURE LIGHT FIXTURE DS UNIT RPP EQUIP EQUIP EQUIP EQUIP EQUIP EQUIP EQUIP EQUIP EQUIP EQUIP EQUIP EQUIP EQUIP EQUIP EQUIP EQUIP EQUIP RPP DS UNIT CAB. CAB. CAB. CAB. CAB. CAB. CAB. CAB. CAB. CAB. CAB. CAB. CAB. CAB. CAB. CAB. CAB. AIR FLOWAIR FLOW i i fi I' I, (, 11 ' i I li �) ii —� sn{I ( ` I ! j k ( I t ie I! ( I 3 I ? I 3 I 1 ; i I ( i UL UrED POWER i CARD t f i I !6 i i I i f I i o.!, ; ! UL t1STEtj POWER CClD j . i "— _ 4d - 4 - 4 ♦ •44 d`" • s _4 r a -•d ,, d T. ' • • d f4 - _ d�a ` •Q A i _ - 4` ▪ -` 4 '` - a- d <- 4 , `d - - �.4 , ELECTRICAL SECTION - 'A -A'. NOT TO SCALE • d a ;�` C,• d • d• 4 - - -4`� _ d d , ./1 • -/ a v d 4 A 4�4 , Q • ••; d ` %<- - • , „Q , - . • d , '� d s' a` , `' / _ . - 4- , • -- A.... C d ,h REVIEWED FOR — COMPLIANCE WITH NFPA 70 6 NEC MAR 14 2014 City of Tukwila BUILDING DIVISION 10400 Rodgers Road HOUSTON, TEXAS 77070 Ph: 281-374-8644 Fax: 281-374-8992 r Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 ISSUES & REVISIONS No. Date Description 1 02/17/2014 ISSUE FOR PERMIT C J Fx.. ES pq. SHEET TULE ELECTRICAL DETAILS RECEIVED CITY OF TUKWILA FEB 2 0 2014 PERMIT CENTER DRAWN: WAM REVIEWED: RWB PROJECT NO.: C1047.00 SHEET NO. E3.5 PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. LIGHT FIXTURE SCHEDULE MARK . LAMPS VOLTAGE DESCRIPTION MANUFACTURERS CATALOG NUMBER MOUNTING REMARKS NO. TYPE A 1 LED 120 WALL MOUNTED LINEAR LIGHTING FIXTURE WITH ALUMINUM FINISH ARCHITECTURAL LIGHTING WORKS ALW WLPD35-4-1-HP10-3500K-LLED-EXTAL WALL MOUNTING HEIGHT- 8'6" AFF. FIELD VERIFY WITH BCEI PRIOR TO ROUGH -IN AE 1 LED 120 WALL MOUNTED LINEAR LIGHTING FIXTURE WITH ALUMINUM FINISH, EMERGENCY BALLAST ARCHITECTURAL LIGHTING WORKS ALW WLPD35-4-1-HP10-3500K-LLED-EXT-AL-EM WALL MOUNTING HEIGHT- 8'6" AFF. FIELD VERIFY WITH BCEI PRIOR TO ROUGH -IN, PROVIDE EMERGENCY BALLAST. 'NL' ADJACENT TO FIXTURE DENOTES UNSWITCHED TO SERVE AS NIGHT/EGRESS LIGHT. B 2 LED UNIVERSAL SURFACE MOUNTED LINEAR LENSED STRIP LIGHTING FIXTURE METALUX METALUX8TSNLED-LD1-115-LC-UNV-L850-CD2-U SURFACE EIGHT FOOT LONG FIXTURE MOUNTED TO CEILING SYSTEM. CLEAR LENS, 2 LED DRIVERS BE 2 LED UNIVERSAL SURFACE MOUNTED LINEAR LENSED STRIP LIGHTING FIXTURE, EMERGENCY BALLAST METALUX METALUX 8TSNLED-LD1-115-LC-UNV-L850-CD2-U-EL SURFACE EIGHT FOOT LONG FIXTURE MOUNTED TO CEILING SYSTEM. CLEAR LENS, 2 LED DRIVERS. PROVIDE EMERGENCY BALLAST. MOUNTING HEIGHT- 8'6" AFF. FIELD VERIFY WITH BCEI PRIOR TO ROUGH -IN, PROVIDE EMERGENCY BALLAST 'NL' ADJACENT TO FIXTURE DENOTES UNSWITCHED TO SERVE AS NIGHT/EGRESS LIGHT. C 1 LED UNIVERSAL 2X2 LAY -IN TROFFER METALUX METALUX22EN-LD1-34-UNV-L840-CD1-U RECESSED CE 1 LED 120 2X2 LAY -IN TROFFER, EMERGENCY BALLAST METALUX METALUX22EN-LD1-34-120-EL14-L835-CD1-U RECESSED PROVIDE EMERGENCY BALLAST INSTALL REMOTE MOUNTED TEST SWITCH G 1 LED UNIVERSAL WALL MOUNTED FLOOD LIGHT McGRAW EDISON IST B02-LED-E1-BL4-GM WALL MOUNT TOP OF FIXTURE 12" BELOW TOP OF SCREEN WALL. FIXTURE SHALL BE FULL CUTOFF: H8 2 LED 120 8 FOOT SURFACE MOUNTED LINEAR LENSED STRIP LIGHTING FIXTURE METALUX - METALUX8TSNLED-LD1-115-LC-UNV-L850-CD2-U SUSPENDED SUSPENDED UTILIZING UNISTRUT SUPPORT H8E 2 LED 120 8 FOOT SURFACE MOUNTED LINEAR LENSED STRIP LIGHTING FIXTURE, EMERGENCY BALLAST METALUX METALUX8TSNLED-LD1-115-LC-UNV-EL-L850-CD2-U SUSPENDED SUSPENDED UTILIZING UNISTRUT SUPPORT, PROVIDE EMERGENCY BALLAST JE 2 LED 120 EXTERIOR WALL MOUNTED EMERGENCY/EGRESS UGH-TING FIXTURE WITH REDUNDANT LED'S DUAL -CITE DUAL LITE PG Z-HTR WALL MOUNT ONE FOOT ABOVE DOOR, CONTAINS BATTERY HEATER FOR COLD OPERATION. BRONZE FINISH K 1 LED 120 WALL MOUNTED SCONCE ARCHITECTURAL LIGHTING WORKS ALW CML-16'-HP14-4000-24"-LED-JBOX2-UNV AL WALL FIELD VERIFY MOUNTING ELEVATION. X1 N/A LED 120 UNIVERSAL MOUNT EDGE LIT EXIT LIGHT COOPER INDUSTRIES EEX-7-X-R WALUCEILING X1 INDICATES SINGLE FACE, X2 INDICATES DOUBLE FACE, PROVIDE ARROWS AS INDICATED, RED FEEDER SCHEDULE MARK FROM TO FEEDER CONDUCTOR QUANTITY AND SIZE CONDUIT SIZE NUMBER OF SETS FEEDER AMPERAGE REMARKS 0001 UTILITY . UTILITY TRANSFORMER PROVIDE PULL STRING 6" 2 N/A NOTE 1 U002 UTILITY TRANSFORMER UTILITY METERING CABINET (3) 400kCM, (1) 400kCM N., (1) 350kCM G 4 8 2500 NOTE 3 001 UTILITY METERING CABINET MSB01000 (3) 500kCM, (1) 500kCM N., (1) 350kCM G 3-1/2" 7 2500 NOTE 2 002 MSB01000 ATSA1000 (3) 300MCM, (1) #1/0 G. 2-1/2" 3 800 003 MSB01000 ATSB1000 (3) 300MCM, (1) #1/0 G. 2-1/2" 3 800 004 MSB01000 ATSB1000 (3) 300MCM, (1) #1/0 G. 2-1/2" 3 800 005 MSB01000 ATSB1000 (3) 300MCM, (1) #1/0 G. 2-1/2" 3 800 006 ATSA1000 MDSA1000 (3) 300MCM, (1) #1/0 G. 2-1/2" 3 800 007 ATSB1000 MDSB1000 (3) 300MCM, (1) #1/0 G. 2-1/2" 3 800 008 ATSC1000 MDSC1000 (3) 300MCM, (1) #1/0 G. 2-1/2" 3 800 009 ATSD1000 MDSD1000 (3) 300MCM, (1) #1/0 G. 2-1/2" 3 800 010 MDSA1000 MBCA1000 (3) 250kCM, (1) #2 G. 2-1/2" 2 500 011 MDSA1000 UPSA1000 (3) #4/0, (1) #2 G. 2" 2 450 012 MDSA1000 MDPA1000 (3) #3/0, (1) #3 G. 2" 2 400 013 MDSB1000 MBCB1000 (3) 250kCM, (1) #2 G. 2-1/2" 2 500 014 MDSB1000 UPSB1000 (3) #4/0, (1) #2 G. 2" 2 450 015 MDSB1000 MDPB1000 (3) #3/0, (1) #3 G. 2" 2 400 016 MDSC1000 MBCC1000 (3) 250kCM, (1) #2 G. 2-1/2" 2 500 017 MDSC1000 UPSC1000 (3) #4/0, (1) #2 G. 2" 2 450 018 MDSC1000 MDPC1000 (3) #3/0, (1) #3 G. 2" 2 400 019 MDSD1000 MBCD1000 (3) 250kCM, (1) #2 G. 2-1/2" 2 500 020 MDSD1000 UPSD1000 (3) #4/0, (1) #2 G. 2" 2 450 021 MDSD1000 MDPD1000 (3) #3/0, (1) #3 G. 2" 2 400 022 MBCA1000 UPSA1000 (3) #3/0, (1) #3 G. 2" 2 400 023 UPSA1000 MBCA1000 (3) #3/0, (1) #3.G. 2" 2 400 024 MBCA1000 PDUA1000 (3) 250kCM, (1) #2 G. 2-1/2" 2 500 025 MBCB1000 UPSB1000 (3) #3/0, (1) #3 G. 2" 2 400 026 UPSB1000 MBCB1000 (3) #3/0, (1) #3 G. 2" 2 400 027 MBCB1000 PDUB1000 (3) 250kCM, (1) #2 G. 2-1/2" 2 500 028 MBCC1000 UPSC1000 (3) #3/0, (1) #3 G. 2" 2 400 029 UPSC1000 MBCC1000 (3) #3/0, (1) #3 G. 2" 2 400 030 MBCC1000 PDUC1000 (3) 250kCM, (1) #2 G. 2-1/2" 2 500 031 MBCD1000 UPSD1000 (3) #3/0, (1) #3 G. 2" 2 400 032 UPSD1000 MBCD1000 (3) #3/0, (1) #3 G. 2" 2 400 033 MBCD1000 PDUD1000 (3) 250kCM, (1) #2 G. 2-1/2" 2 500 034 PDUA1000 RPP01000 (3) #4/0, (1) #4/0 N., (1) #2 G. 2-1/2" 2 450 035 PDUA1000 RPP04000 (3) #4/0, (1) #4/0 N., (1) #2 G. 2-1/2" 2 450 036 PDUA1000 BELOW RAISED FLOOR PULLSTRING 2-1/2" 2 NOTE 5 037 PDUB1000 RPP01000 (3) #4/0, (1) #4/0 N., (1) #2 G. 2-1/2" 2 450 NOTE 4 038 PDUB1000 RPP03000 (3) #4/0, (1) #4/0 N., (1) #2 G. 2-1/2" 2 450 NOTE 4 039 PDUB1000 BELOW RAISED FLOOR PULLSTRING 2-1/2" 2 NOTE 5 040 PDUC1000 RPP02000 (3) #4/0, (1) #4/0 N., (1) #2 G. 2-1/2" 2 450 NOTE 4 041 PDUC1000 RPP03000 (3) #4/0, (1) #4/0 N., (1) #2 G. 2-1/2" 2 450 NOTE 4 042 PDUC1000 BELOW RAISED FLOOR PULLSTRING 2-1/2" 2 NOTE 5 043 PDUD1000 RPP02000 (3) #4/0, (1) #4/0 N., (1) #2 G. 2-1/2" 2 450 NOTE 4 044 PDUD1000 RPP04000 (3) #4/0, (1) #4/0 N., (1) #2 G. 2-1/2" 2 450 NOTE 4 045 PDUD1000 BELOW RAISED FLOOR PULLSTRING 2-1/2" 2 NOTE 5 046 MDPA1000 CRA01000 (3) #1, (1) #8 G. 1-1/2" 1 125 NOTE 4 047 MDPA1000 ERP01000/CON01011/CON02012 (3) #6, (1) #6G. 1" 1 30 NOTE 4, 6 048 MDPB1000 CRA02000 (3) #1, (1) #8 G. 1-1/2" 1 125 NOTE 4 049 MDPB1000 ERP02000/CON03021/CON04022 (3) #6, (1) #6G. 1" 1 30 NOTE 4, 6 050 MDPC1000 TRNC1000 (3) #4, (1) #8 G. 1-1/4" 1 70 NOTE 4 051 TRNC1000 LCPC1000 (3) #1/0, (1) #1/0 N., (1) #6 G. 2" 1 150 NOTE 4 052 MDPC1000 CRA07000 • (3) #6, (1) #10 G. 3/4" 1 50 NOTE 4 053 MDPC1000 CON13071 (3) #8, (1) #8 G. 3/4" 1 20 NOTE 4 054 MDPC1000 CRA03000 (3) #1, (1) #8 G. 1-1/2" 1 125 NOTE 4 055 MDPC1000 ERP03000/CON05031/CON08032 (3) #6, (1) #6G. 1" 1 30 NOTE 4, 6 056 MDPD1000 TRND1000 (3) #4, (1) #8 G. 1-1/4" 1 70 NOTE 4 057 TRND1000 LCPD1000 (3) #1/0, (1) #1/0 N., (1) #6 G. 2" 1 150 NOTE 4 058 MDPD1000 CRA06000 (3) #6, (1) #10 G. 3/4" 1 50 NOTE 4 059. MDPD1000 CON14081 (3) #8, (1) #8 G. 3/4" 1 20 NOTE 4 060 MDPA1000 CRA09000 (3) #10, (1) #10G. 3/4" 1 15 NOTE 4 061 MDPA1000 CON1.7010 (3) #10, (1) #10G. 3/4" 1 15 NOTE 4 062 MDPB1000 CRA10000 (3) #10, (1) #10G. 3/4" 1 15 NOTE 4 063 MDPB1000 CON18901 (3) #10, (1) #10G. 3/4" 1 . 15 NOTE 4 NOTES: 1) COORDINATE ALL REQUIREMENTS WITH THE UTILITY COMPANY. PROVIDE CONCRETE ENCASEMENT. 2) PROVIDE CONCRETE ENCASEMENT. 3) PROVIDE AN ADDITIONAL SPARE (8) 4" CONDUITS 4) PROVIDE LFMC FLEXIBLE CONNECTION AT EQUIPMENT. 5) CAP BELOW RAISED FLOOR. 6) FEEDER INCREASED DUE TO EXPOSED ROUTING ON. ROOF. PROVIDE GRS CONDUIT WHERE EXPOSED ON ROOF. UPS -BATTERY FEEDER SCHEDULE MARK FROM TO FEEDER CONDUCTOR QUANTITY AND SIZE CONDUIT SIZE NUMBER OF SETS FEEDER AMPERAGE REMARKS B001 BATA1001 UPSA1000 PROVIDED BY MANUFACTURER N/A N/A N/A CONTRACTOR INSTALLED B002 BATA1002 UPSA1000 PROVIDED BY MANUFACTURER N/A N/A N/A CONTRACTOR INSTALLED B003 BATB1001 UPSB1000 PROVIDED BY MANUFACTURER N/A N/A . N/A CONTRACTOR INSTALLED B004 BATB1002 UPSB1000 PROVIDED BY MANUFACTURER N/A N/A N/A CONTRACTOR INSTALLED B005 BATC1001 UPSC1000 PROVIDED BY MANUFACTURER N/A N/A N/A CONTRACTOR INSTALLED B006 BATC1002 UPSC1000 PROVIDED BY MANUFACTURER N/A N/A N/A CONTRACTOR INSTALLED B007 BATD1001 UPSD1000 PROVIDED BY MANUFACTURER N/A N/A N/A CONTRACTOR INSTALLED B008 BATD1002 UPSD1000 PROVIDED BY MANUFACTURER N/A N/A N/A CONTRACTOR INSTALLED STANDBY GENERATOR FEEDER SCHEDULE MARK FROM TO FEEDER CONDUCTOR QUANTITY AND SIZE CONDUIT SIZE NUMBER OF SETS FEEDER AMPERAGE REMARKS S001 GEN01000 GSB01000/GSB02000 (4) #400MCM, (1) #2/0 G. 4" 3 1000 NOTE 1 S002 GEN02000 GSB01000/GSB02000 (4) #400MCM, (1) #2/0 G. 4" 3 1000 NOTE 1 S003 FUTURE GEN03000 GSB01000/GSB02000 PULLSTRING 4" 3 NOTE 2 NOTES: 1) PROVIDE LFMC AT CONNECTION TO GENERATOR. 2) STUB UP CONDUITS TO 18" AFG AT FUTURE GENERATOR LOCATION AND CAP. ROUTE CONDUITS TO INTERIOR JUNCTION BOX FAULT CURRENT CALCULATIONS EQUIPMENT ONE LINE REFERENCE EQUIPMENT RATING (AIC) MAXIMUM FAULT 3-PHASE (AMPS) PASS OR FAIL UTIL. MTR. CAB. E1.1 65,000 54,021 PASS MSB01000 E1.1 65,000 52,872 PASS ATSA1000 E1.1 65,000 40,107 PASS MDSA1000 E1.1 65,000 37,740 PASS MBCA1000 E1.1 42,000 34,122 PASS UPSA1000 E1.1 65,000 31,697 PASS MDPA1000 E1.1 42,000 31,661 PASS PDUA1000 E1.1 22,000 16,169 PASS ATSB1000 E1.1 65,000 41,405 PASS MDSB.1000 E1.1 65,000 38,887 PASS MBCB1000 E1.1 42,000 35,057 PASS UPSB1000 - E1.1 65,000 32,502 PASS MDPB1000 E1.1 42,000 32,464 PASS PDUB1000 E1.1 22,000 16,228 PASS ATSC1000 E1.1 65,000 45,371 PASS MDSC1000 E1.1 65,000 42,365 PASS MBCC1000 E1.1 42,000 37,859 PASS UPSC1000 E1.1 65,000 34,897 PASS MDPC1000 E1.1 42,000 33,852 PASS PDUC1000 E1.1 22,000 16,442 PASS ATSD1000 E1.1 65,000 42,365 PASS MDSD1000 E1.1 65,000 39,733 PASS MBCD1000 E1.1 42,000 35,743 PASS UPSD1000 E1.1 65,000 33,091 PASS MDPD1000 E1.1 42,000 31,297 PASS PDUD1000 E1.1 22,000 16,276 PASS RPP01000 A E1.1 22,000 14,117 PASS RPP01000 B E1.1 22,000 13,647 PASS RPP02000 C E1.1 22,000 12,852 PASS RPP02000 D E1.1 22,000 12,281 PASS RPP03000 B E1.1 22,000 12,776 PASS RPP03000 C E1.1 22,000 12,478 PASS RPP04000 A E1.1 22,000 12,685 PASS RPP04000 D E1.1 22,000 11,571 PASS LCPC1000 E1.1 10,000 2,902 PASS LCPD1000 E1.1 10,000 2,894 PASS LOAD ANALYSIS - UTILITY PROJECT: EDGECONNEX TUKWILA, WA EDGECONNEX ELECTRICAL LOADS # DESCRIPTION F.L.A. VOLT. PH. kVA 1 15,570 SF LIGHTING (3.5WSF) X 125% 68.1 1 15,570 SF RECEPTACLE (1WSF) DEMAND PER TABLE 220.44 12.8 1 MISCELLANEOUS 25.0 1 WATER HEATER . 1.5 2 NON DATA CENTER COOLING - - - 50.0 5 DATA CENTER CRACS 93.7 ' 480 3 389.5 1 DATA CENTER CRACS (REDUNDANT, FANS ONLY) 11.0 480 3 9.1 1 UPS/ELEC ROOM CRAGS 39.2 480 3 32.6 1 UPS/ELEC ROOM CRACS (REDUNDANT, FAN ONLY) 10.0 480 3 8.3 10 DATA CENTER ACCU'S 8.4 480 3 69.8 2 DATA CENTER ACCU'S (REDUNDANT) 0.0 480 3 0.0 1 UPS/ELEC ROOM ACCU'S 5.6 480 3 4.7 1 UPS/ELEC ROOM ACCU'S (REDUNDANT) 5.6 480 3 0.0 2 2.9 208 1 2.1 BATTERY EF (1/4HP) 1 800kW CRITICAL LOAD (0.95 pi) 1,083.0 480 3 900.4 1 UPS BATTERY CHARGING (FULL LOAD AT 5%) 60.1 480 3 50.0 1 UPS INEFFICIENCIES (8%) 86.6 480 3 72.0 EDGECONNEX SUBTOTAL (KVA) 1,696.0 SERVICE SIZE AT 480Y/277V, 3-PHASE, 4-WIRE (AMPS) 2,500 AMPS LOAD AT 480Y/277V, 3-PHASE, 4-WIRE (AMPS) 2,040 AMPS SPARE CAPACITY AT 480Y/277V, 3-PHASE, 4-WIRE (AMPS) 460 AMPS MAIN SWITCHBOARD 'MSB01000' DISTRIBUTION PANEL RATINGS: 277/480V, 30, 4W, 2500A DISTRIBUTION PANEL LOADS (1) # DESCRIPTION F.L.A. VOLT. PH. DIV. FACTOR LOAD TOTAL F.L.A. VOLT-AMPERES 1 MDSA1000 680.8 480 3 1.00 680.8 566,000 1 MDSB1000 680.8 480 3 1.00 680.8 566,000 1 MDSC1000 634.3 480 3 1.00 634.3 527,344 1 MDSD1000 637.7 480 3 1.00 637.7 530,187 1 REMOVE REDUNDANT UPS SYSTEM (339.86) 480 3 1.00 (339.9) (282,563) 1 25% LGST MOTOR 7.00 480 3 1.00 7.0 5819.80 DISTRIBUTION PANEL LOAD TOTALS 2,300.7 1,912,788 NOTES: (1) UPS SYSTEMS ARE ARRANGED SO THAT IF ONE UPS SYSTEM FAILS, DOWNSTREAM LOADS SHIFT TO REMAINING ON-LINE UPS SYSTEMS. THEREFORE UPS LOAD OF ONE UPS SYSTEM DEDUCTED FROM THIS SWITCHBOARD LOAD. (2) TOTAL LOAD INDICATED INCLUDES REDUNDANT HVAC SYSTEMS REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC MAR 14 2014 City of Tukwila BUILDING DIVISIO RECEIVED CITY OF TUKWILA FEB 2 0 2014 Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 ISSUES & REVISIONS No. Date Description 1 02/17/2014 ISSUE FOR PERMIT mints C r SHEET TITLE ELECTRICAL SCHEDULES DRAWN: WAM REVIEWED: WAM PROJECT NO.: C1047.00 SHEET NO. E4.1 PERMIT CENTER PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. MAIN DISTRIBUTION PANEL 'MDSA1000' DISTRIBUTION PANEL RATINGS: 480V, 30, 3W, 800A DISTRIBUTION PANEL LOADS # DESCRIPTION F.L.A. VOLT. PH. DIV: FACTOR LOAD TOTAL F.L.A. VOLT-AMPERES 1 UPSA1000 (100% LOADED) 324.9 480 3 1.25 406.1 337,615 1 15.0 480 3 1.00 15.0 12,471 UPSA1000 (BATTERY CHARGING) 1 MDPA1000 259.7 480 3 1.00 259.7 215,915 DISTRIBUTION PANEL LOAD TOTALS 680.8 566,000 MECHANICAL DISTRIBUTION PANEL 'MDPA1000' DISTRIBUTION PANEL RATINGS: 480V, 30, 3W, 400A DISTRIBUTION PANEL LOADS # DESCRIPTION F.L.A. VOLT. PH. DIV. FACTOR LOAD TOTAL F.L.A. VOLT-AMPERES 1 CRA01000 102.7 480 3 1.00 102.7 85,385 1 ERP01000 (NOTE 1) 7.0 480 3 0.00 0.0 0 1 CON01011 11.2 480 3 1.00 11.2 9,312 1 CON02012 11.2 480 3 1.00 11.2 9,312 1 CRA09000 1.4 480 3 1.00 1.4 1,164 1 CON17010 8.1 480 3 1.00 8.1 6,734 1 FUTURE CRA05000 102.7 480 3 1.00 102.7 85,385 1 FUTURE ERP05000 (NOTE 1) 7.0 480 3 0.00 0.0 0 1 FUTURE CON09051 11.2 480 3 1.00 11.2 9,312 1 FUTURE CON10052 11.2 480 3 1.00 11.2 9,312 DISTRIBUTION PANEL LOAD TOTALS 259.7 215,915 NOTES: 1) PUMP IS NON -COINCIDENTAL WITH COMPRESSOR IN ASSOCIATED CRA UNIT. PDU DISTRIBUTION. PANEL 'PDUA1000' DISTRIBUTION PANEL RATINGS: 208/120V, 30, 4W, 800A DISTRIBUTION PANEL LOADS # DESCRIPTION F.L.A. VOLT. PH. DIV. FACTOR LOAD TOTAL F.L.A. VOLT-AMPERES 1 RPP01A01/RPP01A02 0.4 480 3 1.00 0.4 346 1 RPPO4A01/RPPO4A02 8.3 480 3 1.00 8.3 6,928 • DISTRIBUTION PANEL LOAD TOTALS 8.8 7,275 MAIN DISTRIBUTION PANEL 'MDSB1000' DISTRIBUTION PANEL RATINGS: 480V, 30, 3W, 800A DISTRIBUTION PANEL LOADS # DESCRIPTION F.L.A. VOLT. PH. DIV. FACTOR LOAD TOTAL F.L.A. VOLT-AMPERES 1 UPSB1000 (100% LOADED) 324.9 480 3 1.25 406.1 337,615 1 15.0 480 3 1.00 15.0 12,471 UPSB1000 (BATTERY CHARGING) 1 M DP B 1000 259.7 480 3 1.00 259.7 215,915 DISTRIBUTION PANEL LOAD TOTALS 680.8 566,000 MECHANICAL DISTRIBUTION PANEL 'MDPB1000' DISTRIBUTION PANEL RATINGS: 480V, 30, 3W, 400A DISTRIBUTION PANEL LOADS # DESCRIPTION F.L.A. VOLT. PH. DIV. FACTOR LOAD TOTAL F.L.A. VOLT-AMPERES 1 CRA02000 102.7 480 3 1.00 102.7 85,385 1 ERP02000 (NOTE 1) 7.0 480 3 0.00 0.0 0 1 CON03021 11.2 480 3 1.00 11.2 9,312 1 CON04022 11.2 480 3 1.00 11.2 9,312 1 CRA10000 1.4 480 3 1.00 1.4 1,164 1 CON18091 8.1 480 3 1.00 8.1 6,734 1 FUTURE CRA06000 102.7 480 3 1.00 102.7 85,385 1 FUTURE ERP06000 (NOTE 1) 7.0 480 3 0.00 0.0 0 1 FUTURE CON11061 11.2 480 3 1.00 11.2 9,312 1 FUTURE CON12062 11.2 480 3 1.00 11.2 9,312 DISTRIBUTION PANEL LOAD TOTALS 259.7 215,915 NOTES: 1) PUMP IS NON -COINCIDENTAL WITH COMPRESSOR IN ASSOCIATED CRA UNIT. PDU DISTRIBUTION PANEL 'PDUB1000' DISTRIBUTION PANEL RATINGS: 208/120V, 30, 4W, 800A DISTRIBUTION PANEL LOADS # DESCRIPTION F.L.A. VOLT. PH. DIV. FACTOR LOAD TOTAL F.L.A. VOLT-AMPERES 1 RPP01B03/RPP01B04 0.4 480 3 1.00 0.4 346 1 RPPO3B01/RPPO3B02 0.0 480 3 1.00 0.0 0 DISTRIBUTION PANEL LOAD TOTALS 0.4 346 MAIN DISTRIBUTION PANEL 'MDSC1000' DISTRIBUTION PANEL RATINGS: 480V, 30, 3W, 800A DISTRIBUTION PANEL LOADS # DESCRIPTION F.L.A. VOLT. PH. DIV. FACTOR LOAD TOTAL F.L.A. VOLT-AMPERES 1 UPSC1000 (100% LOADED) 324.9 480 3 1.25 406.1 337,615 1 15.0 480 3 1.00 15.0 12,471 UPSC1000 (BATTERY CHARGING) 1 MDPC1000 213.2 480 3 1.00 213.2 177,258 • DISTRIBUTION PANEL LOAD TOTALS 634.3 527,344 MECHANICAL DISTRIBUTION PANEL 'MDPC1000' DISTRIBUTION PANEL RATINGS: 480V, 30, 3W, 400A DISTRIBUTION PANEL LOADS # DESCRIPTION F.L.A. VOLT. PH. DIV. FACTOR LOAD TOTAL F.L.A. VOLT-AMPERES 1 PANEL'LCPC1000' (120/208V) 100.0 480 3 1.00 43.3 36,003 1 CRA07000 39.2 480 3 1.00 39.2 32,591 1 CON13071 5.6 480 3 1.00 5.6 4,656 1 CRA03000 102.7 480 3 1.00 102.7 85,385 1 ERP03000 (NOTE 1) 7.0 480 3 0.00 0.0 0 1 CON05031 11.2 480 3 1.00 11.2 9,312 1 CON06032 11.2 480 3 1.00 11.2 9,312 DISTRIBUTION PANEL LOAD TOTALS 213.2 177,258 NOTES: 1) PUMP IS NON -COINCIDENTAL WITH COMPRESSOR IN CRAC UNIT. PDU DISTRIBUTION PANEL 'PDUC1000' DISTRIBUTION PANEL RATINGS: 208/120V, 30, 4W, 800A DISTRIBUTION PANEL LOADS # DESCRIPTION F.L.A. VOLT. PH. DIV. FACTOR LOAD TOTAL F.L.A. VOLT-AMPERES 1 RPPO2C01/RPPO2CO2 0.0 480 3 1.00 0.0 0 1 RPPO3CO3/RPPO3C04 0.0 480 3 1.00 0.0 0 • DISTRIBUTION PANEL LOAD TOTALS 0.0 0 MAIN DISTRIBUTION PANEL 'MDSD1000' DISTRIBUTION PANEL RATINGS: 480V, 30, 3W, 800A DISTRIBUTION PANEL LOADS # DESCRIPTION F.L.A. VOLT. PH. DIV. FACTOR LOAD TOTAL F.L.A. VOLT-AMPERES 1 UPSD1000 (100% LOADED) 324.9 480 3 1.25 406.1 337,615 1 15.0 480 3 1.00 15.0 12,471 UPSD1000 (BATTERY CHARGING) 1 MDPD1000 216.6 480 3 1.00 216.6 180,101 • DISTRIBUTION PANEL LOAD TOTALS 637.7 530,187 MECHANICAL DISTRIBUTION PANEL 'MDPD1000' DISTRIBUTION PANEL RATINGS: 480V, 30, 3W, 400A DISTRIBUTION PANEL LOADS # DESCRIPTION F.L.A. VOLT. PH. DIV. FACTOR LOAD TOTAL F.L.A. VOLT-AMPERES 1 PANEL'LCPD1000' (120/208V) 107.9 480 3 1.00 46.7 38,846 1 CRA08000 39.2 480 3 1.00 39.2 32,591 1 CON14081 5.6 480 3 1.00 5.6 4,656 1 FUTURE CRA04000 102.7 480 3 1.00 102.7 85,385 1 FUTURE ERP04000 (NOTE 1) 7.0 480 3 0.00 0.0 0 1 FUTURE CON07041 11.2 480 3 1.00 11.2 9,312 1 FUTURE CON08042 11.2 480 3 1.00 11.2 9,312 DISTRIBUTION PANEL LOAD TOTALS 216.6 180,101 NOTES: 1) PUMP IS NON -COINCIDENTAL WITH COMPRESSOR IN ASSOCIATED CRA UNIT. PDU DISTRIBUTION PANEL 'PDUD1000' DISTRIBUTION PANEL RATINGS: 208/120V, 30, 4W, 800A DISTRIBUTION PANEL LOADS # DESCRIPTION F.L.A. VOLT. PH. DIV. FACTOR LOAD TOTAL F.L.A. VOLT-AMPERES 1 RPPO2D03/RPPO2D04 0.0 480 3 1.00 0.0 0 1 RPPO4CO3/RPPO4C04 8.3 480 3 1.00 8.3 6,928 • DISTRIBUTION PANEL LOAD TOTALS 8.3 6,928 El ta 9 113 19 Ea Ea Load (VA) 1,260. 1,260 1,400. 1,200 500. 500. 900 720. 540 29 Ea 111 Ell 2,500 2,500 792 39 Description of Load RCPT - GREEN ROOM RCPT-GREEN ROOM RCPT-.COFFEE MAKER 20/ R 20/ Phase A (VA) 2,142 RCPT- MICROWAVE: PRE -ACTION PACKAGE-1 PRE-AC11ON PACKAGE-1 SPARE. RCPT - ELEC RM/MECH RCPT-DC RCPT - EQUIP YARD/ROOF SPARE SPARE SPARE SPARE. GEN01000 JKT WTR HTR GEN01000 BATT CHG SPARE SPARE Load Type (R) Receptacles. K 201 20/ 20/ :2,167 M 20/ 20/ R 20/ 0 R 20/ R 20/ 20/ 20/ 20/ 40/2 1,290 4,562 H 40/2 4,660 20/ 20/ 40/2 2,160 (C) Cooling (H) Heating (F) Fans (M) Miscellaneous Subtotals: Connected Load 4,680 12,960 23246 0 1,792 16,981 Diversified Load 4,680 0 23,246 0 1;792 Phase B .(VA) 2,050 1,033 900 750 2,160 7,062 2,160 16,1.15 Phase C (VA) 2,042 20/ 201 20/1 L 20/ L Description of Load LIGHTING. LIGHTING DATA CENTER LTG 500 720 20/ 20/ 20/ 20/ 20/ 20/2 WH 4,562 2,160 WH 60/2 H H 30/3 C C 5,354: 60/2 H DATA -CENTER LTG ELEC R LIGHTING. SPARE SPARE SPARE SPARE WATER HEATER WH-1 FCU02000 CON 15120 30/3 C 2,160 17,497 Load Type (L) Lighting (EL) Exterior Lighting (WH) Water Heater C (MT) Largest Motor (SP) Subpanel Connected Load 3,814 0 1,500 0 0 FCU03000 CON20130 Diversified Load 4,768 0 1,500 0 0 Total Connected Load: Total Diversified Load: 50,592 VA 35,986 VA = 141 AMPS 100 AMPS Load: (VA). 882 790 642 967 533 4 750 750. 4,562. 4,562 2,160 2,160 2,160 4,562 4,562 2,160. 2,160 2,160 20 Ea 26 28 30 34 36 LI 40 42 Volts: 208Y.:1_ kAIC: 1-0 -Cu-Bus: 225 MC B : 150 MLO: IEI 9 19 El El El 29 El Load (VA) 1,000 1,000 1;000 500 500 250 360. 500 500 720 540 540 180 720 180 2,500 2,500 792 39 Description of Load ISS-0.1 RACK TRANSFER SEC01000 FAC01000. EPO01000 PHONE BOARD PRE -ACTION :PACKAGE-1 PRE -ACTION PACKAGE-1 RCPT- MECH RCPT - EQUIP YARD/ROOF RCPT - ELEC. RM REHEAT/HUMID LOCKOUT RCPT - DC RCPT- DC CORD REEL GEN02000 JKT WTR HTR GEN02000 BAT!' CHG SPARE. SPARE Load Type (R) Receptacles (C) Cooling (H) Heating (F) Fans (M) Miscellaneous Type Ckt Brkr 20/3 20/ 20/ 20/ 20/ 20/ 20/ 20/ 20/ 20/ 20/ 20/1 Panel: LCPD1000 R 20/ 40/2 MIR re Phase A (VA) 4,742 4,660 20/ 20/1 40/2 2,160 Subtotals: Connected Load 3,060 12,960 23,246 0 5,472 16,719 Diversified Load 3,060 0 23,246 0 5,472 Phase -B (VA) 2,880 7,062 2,160 17,134 Phase C (VA) 5,102 2,340 5,354 20/1 20/ 201 20/ 20. 20/ 20/ 20/ 20/ 20/ 201 60/2 Type L L 30/3 C 60/2 30/3 2,160 17,775 Load Type (L) Lighting (EL) Exterior Lighting (WH) Water Heater (MT) Largest Motor (SP) Subpanel C C Connected Load 5,639 0 0 0 Doorin DoorConstruction: NEMA Rating: Feed Thy: Surf. Mtd: - X Flush Mtd: New/Exist.:--_ NEVI Description of Load LIGHTING LIGHTING DATA CENTER LTG DATA CENTER LTG WAREHOUSE LIGHTING ELEC RM LIGHTING EXF01000 SPARE SPARE SPARE SPARE FCuolo0o CON16110 FCU04000 CON19140 Diversified Load 7,049 0 0 0 0 Total Connected Load: Total Diversified Load:.. 51,627 VA 38;827 VA 143 AMPS 108 AMPS •Load (VA) 1,110 1;101. 642 967 1,391. 428 500 4,562 4.562 2,160 2,160 2;160 4,562 4,562 2;160 2,160 2,160 4 20 113 24 26 28 30 34 36 38 40 42 REVIEWED .FOR COMPLIANCE WITH NFPA70 o NEC MAR 14 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 0 2014 p Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 J '4")>< CD C3 co LIJ CD oo ( ISSUES & REVISIONS No. Date Description 02/17/2014 ISSUE FOR PERMIT SEAL 210-1* SHEET TULE ELECTRICAL SCHEDULES DRAWN: WAM REVIEWED: RWB PROJECT NO.: C1047.00 SHEE'T NO. E4.2 PERMIT CENTER PROPRIETARY: NOT FOR DSCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. Panel: RPPO1AO1 (PANEL 1 Volts: kAIC: Cu Bus: MCB: MLO: 208Y/120 22 225 225 3-Phase, 4-Wire Ckt Load # (VA) Description of Load (Rack ID) Plug Type 'Length Brkr (BLACK) (RED) Whip Type Ckt Phase A Phase B Phase (BLUE) 150 CRA CONT PWR SOUTH M 20/1 2 SPACE 3 SPACE 4 SPACE 5 SPACE 6 SPACE 7 SPACE 8 SPACE 9 SPACE 10 SPACE 11 SPACE 12 SPACE 13 SPACE 14 SPACE 15 SPACE 16 SPACE 17 SPACE 18 SPACE 19 SPACE 20 SPACE 21 SPACE 8Ns 22 SPACE 23 SPACE 24 SPACE 25 SPACE 26 SPACE 27 SPACE 28 SPACE 29 SPACE 30 SPACE 31 SPACE 32 SPACE 33 SPACE 34' SPACE 35 SPACE 36 SPACE 37 SPACE 38 SPACE 39 SPACE 40 SPACE 41 SPACE 42 SPACE Subtotals: 150 0 0 Load Type Connected Load Diversified Load (R) Receptacles 0 0 (C) Cooling 0 0 (H) Heating 0 0 (F) Fans 0 0 (M) Miscellaneous 150 150 (L) Lighting 0 0 (EL) Exterior Lighting 0 (WH) Water Heater 0 0 (MT) Largest Motor 0 0 (SP) Subpanel 0 0 Total Connected Load: 150 VA = 0 AMPS Total Diversified Load: 150 VA = 0 AMPS Panel: RPPOIBO3 (PANEL 3) Volts: kAIC: Cu Bus: MCB: MLO: 208Y/120 22 225 225 3-Phase. 4-Wire Ckt Load # (VA) Description of Load (Rack ID) Plug Type Whip Type Ckt Phase A Phase B Phase C Length Brkr (BLACK) (RED)(BLUE) 150 CRA CONT PWR NORTH 20/1 2 SPACE 3 SPACE 4 SPACE 5 SPACE 6 SPACE 7 SPACE 8 SPACE 9 SPACE 10 SPACE 11 SPACE 12 SPACE 13 SPACE 14 SPACE 15 SPACE 16 17 SPACE SPACE 18 SPACE 19 SPACE -„ 20 SPACE 21 SPACE 22 SPACE 23 SPACE 24 SPACE 25 SPACE 26 SPACE 27 SPACE 28 SPACE 29 SPACE 30 SPACE 31 SPACE 32 SPACE 33 SPACE • 34 SPACE 35 SPACE 36 37 38 39 40 41 42 SPACE SPACE SPACE SPACE SPACE SPACE SPACE Subtotals: 150 0 Load Type Connected Load Diversified Load (R) Receptacles 0 0 (C) Cooling 0 0 (H) Heating 0 0 (F) Fans 0 0 (M) Miscellaneous 150 150 (L) Lighting 0 0 (EL) Exterior Lighting 0 0 (WH) Water Heater 0 0 (MT) Largest Motor 0 (SP) Subpanel 0 0 Total Connected Load: 150 VA = 0 AMPS Panel: - RPPO1 AQ2 (PANEL 2 Volts: 208Y1120 kAIC: 22 Cu Bus: 225 1v1CB: 225 MLO: 3-Phase, 4-Wire Ckt Load # (VA) Description of Load. (Rack ID) Plug Type Whip Type Ckt Phase A Phase B Phase C Length Brkr (BLACK) (RED) (BLUE) SPACE 2 SPACE 3 SPACE 4 SPACE 5 SPACE 6 7 8 SPACE SPACE SPACE 9 SPACE 10' SPACE 11 SPACE 12. SPACE 13 SPACE r:. 14 SPACE 15 SPACE 16 SPACE 17' SPACE 18 SPACE 19 SPACE 20 SPACE 21 SPACE 22 SPACE 23 SPACE 24 SPACE 25 SPACE 26 SPACE 27 SPACE 28 SPACE 29 SPACE 30 SPACE 31 SPACE 32 SPACE 33 SPACE 34 SPACE 35 SPACE 36 SPACE 37 SPACE 38 SPACE 39 SPACE 40 SPACE 41 SPACE 42 SPACE Subtotals: 0 0 Load Type Connected Load Diversified Load (R) Receptacles 0 0 (C) Cooling 0 0 (H) Heating 0 0 (F) Fans 0 0 (M) Miscellaneous 0 0 (L) Lighting 0 (EL) Exterior Lighting 0 0 (WH) Water Heater 0 (MT) Largest Motor 0 (SP) Subpanel 0 0 Total Connected Load: 0 VA = 0 AMPS Total Diversified Load: 0 VA = 0 AMPS Panel: RPPO1B04 (PANEL 4) Volts: kAIC: Cu Bus: MCB: MLO: 208Y/120 22 225 225 -Phase. 4-Wire Ckt Load # (VA) Description of Load (Rack ID) Plug Type Whip Type Ckt Phase A Phase B Phase C Length Brkr (BLACK)' (RED) (BLUE) SPACE 2 SPACE 3 SPACE 4 SPACE 5 SPACE 6 SPACE 7 SPACE 8 SPACE 9 SPACE 10 SPACE SPACE 12 SPACE 13 SPACE 14 SPACE 15 SPACE 16 SPACE 17 SPACE 18 SPACE 19 SPACE 20 SPACE 21. SPACE 22 SPACE 23 SPACE 24 SPACE 25 SPACE 26 SPACE 27 SPACE 28 SPACE 29 SPACE 30 SPACE 31 SPACE 32 SPACE 33 34 SPACE SPACE 35 SPACE SPACE 37 SPACE SPACE 39 SPACE 40 SPACE 41 SPACE 42 SPACE btota Is: Load Type Connected Diversified Load Load (R) Receptacles 0 0 (C) Cooling 0 (H) Heating 0 0 0 0 (M) Miscellaneous 0 0 (L) Lighting 0 0 (EL) Exterior Lighting 0 0 (WH) Water Heater 0 0 (MT) Largest Motor 0 0 (SP) Subpanel 0 Total Connected Load: 0 VA 0 AMPS 4 6 9 10 14 Eal 18 19 20 24 Load (VA) 121 26 Deecription of Load (Rack ID) SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE 28 SPACE Plug Type SPACE SPACE 29 30 Es SPACE SPACE 34 36 38 39 40 SPACE SPACE SPACE 42 SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE Whip Length Type Phase A (BLACK) Phase B. (RED) Phase C (BLUE) Load Type (R) Receptacles (C) Cooling (H) Heating (F) Fans (M) Miscellaneous (L) Lighting (EL) Exterior Lighting (WH) Water Heater (MT) Largest Motor pp) Subpanel Subtota Is: Connected Load 0 0 0 0 0 0 0 0 0 Total Connected Load: Total Diversified Load: Diversified Load 0 0 0 0 0 0 0 0 0 VA VA 0 AMPS 0 AMPS Panel: RPPO2D03 (PANEL 3) Volts: kAIC: Cu Bus: MCB: MLO: 208Y/120 22 225 3-Phase, 4-Wire Ckt Load # (VA) Description of Load (Rack ID) Plug Type Whip Type Ckt Phase A Phase B Phase C Length Brkr (BLACK) (RED) (BLUE) SPACE 2 SPACE 3 4 5 SPACE SPACE SPACE 6 SPACE SPACE SPACE 9 SPACE 10 SPACE 11 SPACE 12 SPACE 13 SPACE 14 SPACE 15 SPACE 16 SPACE 17 SPACE 18 SPACE 19 SPACE 20 SPACE 21 SPACE 22 SPACE 23 SPACE 24 SPACE 25 SPACE 26 SPACE 27 SPACE 28 SPACE 29 SPACE SPACE 31 SPACE 32 SPACE: 33 SPACE 34 SPACE 35 SPACE 36 SPACE 37 SPACE 38 SPACE 39 SPACE 40 SPACE 41 SPACE 42. SPACE Load Type (R) Receptacles (C) Cooling (H) Heating (M) Miscellaneous (L) Lighting (EL) Exterior Lighting (WH) Water Heater (MT) Largest Motor (SP) Subpanel Connected Diversified Load Load 0 0 0 0 0 0 0 0 VA Total Connected Load: 0 0 0 AMPS Ckt Load # (VA) Description of Load (Rack ID) Whip- Type Ckt Phase A. Phase B Phase. C Type Length Brkr (BLACK) (RED) (BLUE) Plug SPACE 2 SPACE 3 SPACE SPACE 5 SPACE 6 SPACE 7 SPACE 8 SPACE 9 SPACE SPACE 11 SPACE 12 SPACE 13 SPACE 14 SPACE 15 SPACE 16 SPACE 17 SPACE 8 SPACE 19 SPACE 20 SPACE 21 SPACE 22 SPACE 23 SPACE 24 SPACE 25 SPACE 26 SPACE 27 SPACE 28 SPACE 29 SPACE 30 SPACE 31 SPACE 32 SPACE 33 SPACE 34 SPACE 35 SPACE 36 SPACE 37 SPACE 38 SPACE 39 SPACE 40 SPACE 41 SPACE 42 SPACE Subtotals: 0 oad Type Connected Diversified (R) Receptacles 0 (C) Cooling 0 0 (H) Heating 0 P) Pans 0 ) Miscellaneous 0 0 (L) Lighting 0 (EL) Exterior Lighting 0 (WH) Water Heater 0 0 (MT) Largest otor 0 (SP) Subpanel 0 Panel: RPPO2D04 (PANEL 4 Volts: Cu Bus: MCB: MLO: 225 225 Ckt Load # (VA) Description of Load (Rack ID) Total Connected Load: 0 VA Total Diversified Load: 0 VA -Phase, 4-Wire 0 AMPS 0 AMPS Plug Whip Type Ckt Phase A Phase B Phase C Type Length Brkr LACK) (RED) (BLUE) SPACE 2 SPACE 3 SPACE 4 SPACE 5 SPACE 6 SPACE 7 SPACE SPACE SPACE 10 SPACE 11 SPACE 12 SPACE 13 SPACE 14 SPACE 15 SPACE 16 SPACE 17 SPACE 18 SPACE 19 SPACE 20 SPACE 21 SPACE 22 SPACE 23 SPACE 24 SPACE 25 SPACE 26 SPACE 27 SPACE 28 SPACE 29 SPACE 30 SPACE 31 SPACE 32 SPACE 33 SPACE 34 SPACE 35 SPACE 36 SPACE 37 SPACE 38 SPACE 39 SPACE 40 SPACE 41 SPACE 42 SPACE oad Type Connected Diversified Load Load (R) Receptacles (C) Cooling 0 0 ) Heating 0 F) Pans (M) Miscellaneous 0 0 ) Lighting 0 0 (EL) Exterior ighting 0 0 (WH) Water Heater 0 0 (MT) Largest otor (SP) Subpanel 0 10400 Rodgers Road HOUSTON, TEXAS 77070 Ph: 281-374-8644 Fax: 281-374-8992 Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 REVIEWED FOR COMPLIANCE WITH MAR 1 4 2014 City of Tukwila BUILDING DIVISION Total Connected Load: 0 VA 0 AMPS ISSUES & REVISIONS No. Date Description 02/17/2014 ISSUE FOR PERMIT SEAL SHEET TITLI3 ELECTRICAL SCHEDULES Total Diversified Load: 150 VA 0 AMPS Total Diversified Load: 0 VA 0 AMPS Total Dikersiffed Load: 0 VA 0 AMPS Total Dil,ersified Load: 0 VA 0 AMPS RECEIVED CI It OF TUKWILA FEB 2 0 2014 PERNNT CENTER DRAWN: WAM REVIEWED: RWB PROJECT NO.: C1047.00 SHEET NO. E4.3 PROPRIETARY: NOT FOR DSCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. Panel: RPPO3B01 (PANEL 1) Volts: kAIC: Cu Bus: MCB: MLO: Ckt Load # (VA) 208Y/120 22 225 225 Description of Load' (Rack ID) Plug Type -Phase, 4-Wire Whip Type Ckt Phase A Phase B Phase C Length Brkr (BLACK (RED) (BLUE) SPACE 2 SPACE 3 4 5 6 SPACE SPACE SPACE SPACE 7 SPACE 8 SPACE 9 SPACE 10 SPACE 11 SPACE 12 SPACE 13 SPACE 14 SPACE 15 SPACE 16 SPACE 17 SPACE 18 SPACE 19 SPACE 20 SPACE 21 SPACE 22 SPACE -Yi'N'yfa" 23 SPACE 24 SPACE 25 SPACE 26 SPACE 27 SPACE 28 SPACE 29 SPACE 30 SPACE 31 SPACE 32 SPACE 33 SPACE 34 SPACE 35 SPACE 36 SPACE 37 SPACE 38 SPACE 39 SPACE 40 SPACE 41 SPACE 42 SPACE Subtotals: 0 0 0 Load Type Connected Load Diversified Load (R) Receptacles• O 0 (C) Cooling O 0 (H) Heating 0 0 (F) Fans 0 (M) Miscellaneous O 0 (L) Lighting 0 0 (EL) Exterior Lighting .0 (WH) Water Heater O 0 (MT) Largest Motor t 0 (SP) Subpanel 0 0 Total Connected Load: Total Diversified Load: 0 VA = 0 AMPS 0 VA = 0 AMPS Load (VA) 4 6 8 9 10 14 16 18 19 20 Ed 24 26 28 29 Description of Load (Rack ID) SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE: SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE. SPACE 30 tu rai 34 Ed 36 IEU u 39 40 42 SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE Load Type (R) Receptacles (C) Cooling (H) Heating (F) Fans (M) Miscellaneous (L) Lighting (EL) Exterior Lighting (WH) Water Heater (MT) Largest Motor (SP) Subpanel Plug Type Whip Length Type Subtotals: Connected Load 0 0 O O 0 O O 0 Total Connected Load: Total Diversified Load: Phase A (BLACK) 0 Diversified Load 0 0 0 0 0 0 0 0 0 0 O VA = O VA = Phase 8 (RED) 0 Phase C (BLUE) 0 0 AMPS 0 AMPS Panel: RPPO3B02 (PANEL 2) Volts: kAIC: Cu Bus: MCB: MLO: Ckt Load # (VA) 208Y/120 22 225 225 Description of Load (Rack ID) SPACE Plug Type 3-Phase, 4-Wire Whip Type Ckt Phase A Phase B Phase C Length Brkr (BLACK) (RED) (BLUE) 2 SPACE 3 SPACE 4 SPACE 5 SPACE 6 SPACE 7 SPACE 8 SPACE 9 SPACE 10 SPACE 11 SPACE 12 SPACE 13 SPACE 14 SPACE 15 SPACE 16 SPACE 17 SPACE 18 SPACE 19 SPACE 20 SPACE 21 SPACE 22 SPACE 23 SPACE 24 SPACE 25 SPACE 26 SPACE 27 SPACE 28 SPACE 29 SPACE 30 SPACE 31 SPACE 32 SPACE 33 SPACE 34 SPACE 35 SPACE 36 SPACE 37 SPACE 38 SPACE 39 SPACE 40 SPACE 41 SPACE 42 SPACE Load Type Subtotals: Connected Load 0 Diversified Load (R) Receptacles 0 0 (C) Cooling a 0 (H) Heating 0 0 (F) Fans 0 0 (M) Miscellaneous 0 0 (L) Lighting 0 0 (EL) Exterior Lighting 0 0 (WH) Water Heater 0 0 (MT) Largest Motor 0 (SP) Subpanel 0 0 0 0 Total Connected Load: 0 VA Total Diversified Load: 0 VA 0 AMPS = 0 AMPS lEll 4 6 8 9 10 14 16 m Load (VA) 19 20 iu ID 24 Ea 26 28 29 30 34 Description of Load (Rack ID) SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE 36 38 39 40 42 SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE Plug Type Whip Length Type Ckt Brkr SPACE SPACE SPACE SPACE SPACE SPACE SPACE Load Type (R) Receptacles (C) Cooling (H) Heating. (F) Fans (M) Miscellaneous (EL) Exterior Lighting (WH) Water Heater (MT) Largest Motor (SP) Subpanel Subtota Is: Connected Load 0 Total Connected Load: Total Diversified Load: Phase A (BLACK) 0 DiVers lied Load 0 0 VA Phase B (RED) 0 Phase C (BLUE) 0 0 AMPS 0 VA 0 AMPS Panel: RPPO4A01 PANEL I) Cu Bus: 225 - MCB: 225 MLO: Ckt Load 1,000 Description of Load (Rack ID) Plug Type L21-20R 3-Phas 4-Wire Whip Type Ckt Phase A Phase B Phase C Length Brkr (BLACK) (RED) (BLUE) 33 20/3 2 1,000 (IN ISS ROOM) 3 1,000 4 SPACE 5 SPACE 6 SPACE 7 SPACE 8 SPACE 9 SPACE 10 SPACE 11 SPACE 12 SPACE 13 SPACE 14 SPACE 15 SPACE 16 SPACE 17 SPACE 18 SPACE 19 SPACE 20 SPACE 21 SPACE 22 SPACE 23 SPACE SPACE 25 SPACE 26 SPACE 27 SPACE 28 SPACE 29 SPACE 30 SPACE 31 SPACE 32 SPACE 33 SPACE 34 SPACE 35 SPACE 36 SPACE 37 SPACE 38 SPACE 39 SPACE 40 SPACE 41 SPACE 42 SPACE 1,000 1,004 1,000 Load Type (R) Receptacles (C) Cooling Connected Load Diversified Load (F) Fans (M) Miscellaneous 3,000 3,000 (L) Lighting (EL) Exterior Lighting (WH) Water Heater (MT) Largest Motor (SP) Subpanel Total Connected Load: 3,000 VA 8 AMPS Total Diversified Load: 3,000 VA 8 AMPS Panel: RPPO4D03 (PANEL 3) Volts: kAIC: Cu Bus: MCB: MLO: 22 225 3-Phase. 4-Wire Ckt Load # (VA) Description of Load (Rack ID) Plug Type Whip Type Ckt Phase A Phase B Phase C Length Brkr (BLACK) (RED) (BLUE) L21-20R 33 20/3 2 1,000 (IN ISS ROOM) 3 1,000 4 SPACE 5 SPACE 6 SPACE 7 SPACE 8 SPACE 9 SPACE 10 SPACE 11 SPACE 12 SPACE 13 SPACE 14 SPACE 15 SPACE 16 SPACE 17 SPACE 18 SPACE 19 20 SPACE SPACE 21 22 SPACE SPACE 23 SPACE 24 SPACE 25 spikpE 26 SPACE 27 SPACE SPACE 29 SPACE 30 SPACE 31 SPACE 32 SPACE 33 SPACE 34 SPACE 35 SPACE 36 SPACE 37 SPACE 38 SPACE 39 SPACE 40 SPACE 41 SPACE 42 SPACE 1,000 1,000 1,000 Load Type Connected Load Diversified Load (R) Receptacles (C) Cooling (H) Heating (F) Fans (M) Miscellaneous 3,000 3,000 (L) Lighting (EL) Exterior Lighting (WH) Water Heater (MT) Largest Motor (SP) Subpartel Total Connected Load: 3,000 VA 8 AMPS Total Diversified Load: 3,000 VA 8 AMPS kAIC: Cu Bus: MCB: MLO: Ckt Load # (VA) 225 Description of Load (Rack ID) Plug Type -Phase, 4-Wire Whip Type Okt Phase A Phase B Phase C Length Brkr (BLACK) (RED) (BLUE) SPACE . 2 SPACE 3 SPACE 4 SPACE 5 SPACE 6 SPACE 7 SPACE 8 SPACE 9 SPACE 10 SPACE 11 SPACE 12 SPACE 13 SPACE 14 SPACE 15 SPACE 16 SPACE 17 SPACE 18 SPACE 19 SPACE 20 SPACE 21 SPACE 22 SPACE 23 SPACE 24 SPACE 25 SPACE 26 SPACE 27 SPACE 28 SPACE 29 SPACE 30 SPACE 31 SPACE 32 SPACE 33 SPACE 34 SPACE 35 SPACE 36 SPACE 37 SPACE 38 SPACE 39 SPACE 40 SPACE 41 SPACE 42 SPACE 0 0 0 Load Type Connected Load Diversified Load (R) Receptacles (C) Cooling (H) Heating (F) Fans (M) Miscellaneous (L) Lighting (EL) Exterior Lighting (WH) Water Heater (MT) Largest Motor (SP) Subpanel Panel: RPPO4D04 (PANEL 4) Volts: kA IC: Cu Bus: MCB: MLO: 22 225 Ckt Load # (VA) Total Connected Load: Description of oad (Rack ID) Plug Type Total Diversified Load: 0 VA 0 VA 3-Phase, 4-Wire 0 AMPS 0 AMPS Whip Type Ckt Phase A Phase B Phase C Length Brkr (BLACK) (RED) (BLUE) SPACE 2 SPACE 3 SPACE 4 SPACE 5 SPACE 6 SPACE 7 SPACE 8 SPACE 9 SPACE 10 SPACE 11 SPACE 12 SPACE 13 SPACE 14 SPACE 15 SPACE 16 SPACE 17 SPACE 18 SPACE 19 SPACE 20 SPACE 21 SPACE 22 SPACE 23 SPACE 24 SPACE 25 SPACE 26 SPACE 27 SPACE 28 SPACE 29 SPACE 30 SPACE 31 SPACE 32 SPACE 33 SPACE 34 SPACE 35 SPACE 36 SPACE 37 SPACE 38 SPACE 39 40 41 SPACE SPACE SPACE 42 SPACE 0 0 Load Type Connected Load Diversified Load (R) Receptacles (C) Cooling (H) Heating (F) Fans 0 (M) Miscellaneous (L) Lighting (EL) Exterior Lighting 0 (VVH) Water Heater (MT) Largest Motor (SP) Subpanel Total Connected Load: 0 VA Total Diversified Load: 0 VA 0 AMPS 0 AMPS REVIEWED FOR COMPLIANCE WITH City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA 10400 Rodgers Road HOUSTON, TEXAS 77070 Ph: 281-374-8644 Fax: 281-374-8992 Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 ISSUES & REVISIONS No. Date Description 02/17/2014 ISSUE FOR PERMIT EXPIRES SEAL az Mt+ SHEET TITLE ELECTRICAL SCHEDULES PERMIT CENTER DRAWN: WAM REVIEWED: RWB PROJECT NO.: C1047.00 SHEET NO. E4.4 PROPRIETARY: NOT FOR DSCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC.