Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL14-0341 - WELLS FARGO - SWITCHBOARD
WELLS FARGO 6847 S 180 ST EL1 4-0341 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 3623049079 6847 S 180 ST 1 WELLS FARGO ELECTRICAL PERMIT Permit Number: EL14-0341 Issue Date: 4/29/2014 Permit Expires On: 10/26/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WELLS FARGO BANK PO BOX 2609 C/0 THOMSON PROPERTY TAX SER, CARLSBAD, WA, 92018 PETER MQUILLAN 18035 WEST SPERRY DR , TUKWILA, WA, 98188 NELSON ELECTRIC 9620 STONE AV N, STE 201, SEATTLE, WA, 98103 NELSOEI132CZ I!/ Phone: (206) 575-5618 Phone: (206) 523-4525 Expiration Date: 2/12/2015 DESCRIPTION OF WORK: REMOVE AND REPLACE EXISTING 800A 277/480V SWITCHBOARD Valuation of single family: $0.00 Valuation of mf/comm: $43,750.00 Type of Work: SERV CHNG Fees Collected: $1,135.68 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer Distric: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: Permit Center Authorized Signature: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: t�- 2012 2012 2012 Date: ��� 11 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: c\K�/1f\ Date:_" al - aO\C\ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWi Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWkgov Electrical Permit No. 6ut ^ 0i I Project No. Date Application Accepted: 04 LEA, i(.4 Date Application Expires: t 0 H, I"f (For office use cub!) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review: Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: ?C(' L�04-1 'O Site Address: 6847 S 180th Street Tenant Name: Wells Fargo PROPERTY OWNER Name: Wells Fargo Address: 18035 West Sperry Drive City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Peter McQuillan Address: 18035 West Sperry Drive City: Tukwila State: WA Zip: 98188 Phone: (206) 575-5618 Fax: Email: peter.j.mcquillan@wellsfargo.com Suite Number: Floor: Elect Room New Tenant: ❑ Yes ®..No ELECTRICAL CONTRACTOR INFORMATION Company Name: Nelson Electric Address: 9620 Stone Avenue North Suite 201 City: Seattle State: WA Zip: 98103 Phone: 206 523-4525 Fax: 206 527-9539 Contr Reg No.: NELSOEI132CZ Exp Date: 2/12/ 015 Tukwila Business License No.; BUS-0994260 >" Valuation of Project (contractor's bid price): . $ 43,750.00 Scope of Work (please provide detailed information): Remove and replace existing 800A 277/480V Switchboard. Will service be altered? ® Yes ❑ No Adding more than 50 amps? ❑ Yes EN No Type of use: Commercial Office Building Type of work: ❑ New ❑ Addition OS Service Change Low Voltage ❑ Generator ❑ Fire Alarm Property Served by: a Puget Sound Energy ❑ Seattle City Light H: Applications Forms -Applications On Line 2014 Applications Electrical Permit Application Revised I-1-f 4 docx Revised. January 2014 bh ❑ Remodel ❑ Telecommunication 0 Tenant Improvement ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $1 1.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change ...... $54.60 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $65.00 ❑ Temporary service (generator) $80.90 ❑ Manufactured/mobile home service $86.25 (excluding garage or outbuilding) ❑ Carnivals $80.60 Number of concessions $10.80 ea Each ride and generator truck $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: '/mil_.L 241.1 11Z Print Name: Red Sandbloom Mailing Address: 9620 Stone Avenue North Suite 201 Date: April 14, 2014 Day Telephone: 206 523-4525 Seattle WA City state 98103 Zip H: Applications Forms -Applications On Line 2014 Applications Electrical Permit Application Revised I-I-14 does Revised: January 2014 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT QUANTITY PAID $417.28 EL14-0341 Address: 6847 S 180 ST 1 Apn: 3623049079 $417.28 ELECTRICAL $373.60 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 $373.60 TECHNOLOGY FEE $43.68 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R1958 R000 322.900.04 00 $43.68 $417.28 Date Paid: Tuesday, April 29, 2014 Paid By: DAVID SANDBLOOM Pay Method: CREDIT CARD 046202 Printed: Tuesday, April 29, 2014 11:42 AM 1 of 1 CR SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT I QUANTITY PAID PermitTRAK $500.00 EL14-0341 Address: 6847 S 180 ST 1 Apn: 3623049079 $500.00 ELECTRICAL $500.00'`'' PERMIT FEE MULTI-FAM/COMM TOTAL FEES PAID BY RECEIPT: R1957 R000.322.101.00.00 $500.00 $500.00 Date Paid: Tuesday, April 29, 2014 Paid By: ERIK POLSON NELSON ELECTRIC Pay Method: CREDIT CARD 060560 Printed: Tuesday, April 29, 2014 11:32 AM 1 of 1 CRWSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID $218.40 EL14-0341 Address: 6847 S 180 ST 1 Apn: 3623049079 $218.40 ELECTRICAL $218.40 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R1796 R000.345.832.00.00 $218.40 $218.40 Date Paid: Monday, April 14, 2014 Paid By: NELSON ELECTRIC INC Pay Method: CREDIT CARD 011234 Printed: Monday, April 14, 2014 1:50 PM 1 of 1 SYSTEMS S TE.Dw0 4/9/2014 1:24 PM 8 8 8 5 8 o\PROJECTS\201} PROJECTS\13102 EXTERIOR INTERIOR EXISTING PSE REMOTE WIRELESS METER COAST ELECTRIC SWITCHBOARD 800A 480/277V (TO BE REMOVED) PSE UTILITY TRANSFORMER T. I •a n � ¢4a 4% O •8 � ' � ' C � ' N )� ry UTILITY PRIMARY (2) SETS 4-500Kcmi1 EXISTING RISER DIAGRAM EXISTING 4j94/0 (CU) EXISTING 492/0 (CU) -ePANEL PB --PANEL LA EXISTING 492 (CU) UNDERGROUND CONDUIT RUNS FOR DISTRIBUTION FEEDER 5O [ACC EXISTING TELE/DATA 2-POST RACKS COAST ELECTRIC SWITCHBOARD 800A 480/277V (TO BE REMOVED) PSE VARELESS METER (TO REMAIN) ";; EXISTING PSE Ns.150KV PAD MOUNT TRANSFORMER \\ Ns. Ns. I 1 °ELECTRICAL ROOM PLAN - DEMOLITION 1 SCALE: 1/4" = 1'-0" REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. NEW UTILITY CT ENCLOSURE 800A RATED EXTERIOR INTERIOR ci(2) SETS 3-1/2" RIGID, 4-500kcmil(CU) ©EXISTING PSE REMOTE `- WIRELESS METER ALIGN CT ENCLOSURE WITH EXISTING UTILITY RACEWAYS. PSE UTILITY TRANSFORMER T g 200A/3P 175A/3P 100A/3P 800A 480Y/277V, 3PH 4W NEW 2-1/2"C., 494/0 (CU) - NEW 2"C, 4b2/0 (CU) _moo NEW 1-1/4"C. 492 (CU) -gym PROVIDE NEW SUITABLE SPLICE/PULL BOX TO INTERCEPT EXISTING FEEDERS EXISTING 4/4/0 (CU) TO PSE UTILITY ( SPLICE VAULT 4\-(2 SETSQ4 4-5008cm1 NEW RISER DIAGRAM ` EXISTING 492/0 (CU) -!ll���/// EXISTING PANEL P8 EXISTING PANEL LA -- XISTING PANEL LB EXISTING 492 (CU) CD®ELECTRICAL ROOM PLAN - NEW ELECTRICAL 1/4" = EXISTING ROOM CONDITION PROVIDE NEW SUITABLE SPLICE/PULL BOX TO INTERCEPT EXISTING FEEDERS I D-'6 [LET: 4"34j34=� REVIINED FOR COMPLIANCE WITH NFPA 70 - NEC APR 2 8 2014 City o BUILDING EXISTING TELE/DATA 2-POST RACKS PLAN VIEW OF NEW WORK FILE COP Permit No. F U \ Plan review approval is subject errors and omissions. L8 ;:{►-cAval of construction documents does not authorize :o ation of any adopted code or ordnance. Receipt of approved Field and eondidors is aclmowledged: la VISION PROVIDE NEW CT ENCLOSURE MAINTAIN EXISTING PSE WIRELESS METER< EXISTING PSE ss. 150KV PAD MOUNT Ns. '1 TRANSFORMER NN � b11 GENERAL NOTES: I. SEE ACCOMPANYING SCOPE OF WORK DOCUMENT FOR SHUTDOWN REQUIREMENTS AND OTHER CONTRACTOR RESPONSIBILITIES AS PART OF THIS PROJECT, FLAG NOTES: E> DISCONNECT ALL EXISTING FEEDERS. MAINTAIN FOR FUTURE EXTENSION TO NEW SERVICE PANEL. CONTRACTOR TO MAINTAIN/REUSE OR PROVIDE NEW SERVICE LATERALS FOR CONNECTION TO NEW CT'S IN ACCORDANCE WITH SERVING UTILITY REQUIREMENTS. RECONNECT EXISTING UTILITY METER SYSTEM IN ACCORDANCE WITH SERVING UTLITY REQUIREMENTS. CONTRACTOR SHALL INCLUDE SEPARATE BREAKOUT ALLOWANCE FOR REPLACEMENT OF METERING SHOULD THIS BE REQUIRED PER SERVING UTILITY. PROVIDE SUITABLE PULL BOX FOR INTERCEPTION/SPLICE/EXTENSION OF EXISTING FEEDER CONDUCTORS, NOT USED © PROVIDE I -LINE STYLE SR RATED DISTRIBUTION PANEL. PANEL BUSSING AND OVER CURRENT PROTECTION DEVICES SHALL MEET/EXCEED AVAILABLE UTILITY SECONDARY FAULT VALUES. PANEL SHALL BE PROVIDED WITH RATED MAIN BREAKER, MINIMUM 400A FRAME FEEDER BREAKER ACCOMMODATION AND SHALL LEAVE 300 SPARE AVAILABLE SPACE FOR ADDITIONAL FEEDER BREAKERS UPON RECONNECTION OF EXISTING PANEL FEEDERS. BASIS OF DESIGN: SQUARE D I -LINE STYLE TYPE HCP-SU DISCONNECT EXISTING GROUNDING ELECTRODE SYSTEM (GES). MAINTAIN FOR CONNECTION TO REPLACEMENT EQUIPMENT. EXTEND EXIST GES. GROUND/BOND IN ACCORDANCE WITH NEC 250 REQUIREMENTS. NOT USED LINE UP CT ENCLOSURE WITH EXISTING INCOMING UTILITY RACEWAYS. n SERVICE ENTRANCE CONDUCTORS FIELD VERIFIED AS COPPER WITH SIZE AS NOTED. CT ENCLOSURE TO SERVICE PANEL RACEWAYS TO BE RIGID STEEL WITH CONDUCTOR DISTANCE <15' TERMINAL TO TERMIANL. PROVIDE A NEW 800A 480/277V I -LINE (TYPE HCP-SU) PANELBOARD B Date L(- ao►y City Of Tukwila RECEIVED BUILDING DIVISIONY OF TUKWILA APR 14 2014 PERMIT CENTER —2 SYMBOLS LEGEND NEW VARING WITH CONDUIT SURFACE MOUNTED NEW WIRING WITH CONDUIT IN OR BELOW SLAB OR BELOW GRAC EXISTING RACEWAY OR WIRING RACEWAY STUB -OUT WITH BUSHING HOME RUN TO PANEL OR LOCATION NOTED CIRCUIT CONTINUATION PANEL - 480 VOLT SYSTEM, +6' TO TOP U.N.O. —r CIRCUIT BREAKER 0-9 SPERRY DRIVE SOUTH FUSED SWITCH GROUND AVAILABLE SHORT CIRCUIT CURRENT METER PANEL SOUTH 180TH STREET BUILDING KEY PLAN QP SCALE: NONE €L1L4 -o4; I EXPIRES 1-17-)6 I BrN Engineering, Inc. Electrical Consulting Engineering 2103,d Avenue S.. Suio 2C 101 (206)223.6446 Ssalf'e. Washin)lm e6164 tan: )206)223.6465 NELSON ELECTRIC W 0 a. 0 W CU < 5 (n W (n J J W FE >U U W w REV # 6847 SOUTH 180TH STREET TUKWILA, WASHINGTON 98188 DATE DRAWN SH CHECKED BB DATE 04/09/2014 SHEET TITLE: ELECTRICAL SITE PLAN RISER DIAGRAMS E1.1 INSPECTION RECORD Retain a copy with permit INSSPCTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: 0 KO 64441 Type of Inspection: .•••"-- ii.ai Address: aql Date Called: Special Instructions: tD,vv Date Wanted: (( 7 f (a.m. m, Requester: i Phone No: Approved per applicable codes. D Corrections required prior to approval. COMMENTS: tAi IV 41 rzi t`Q Inspector: Date: D i / 4 / r � REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 11,61tAJAIK INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. fi,111-o3tif CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: (Akio J Type of Inspection ._ `�, G Address: 6347 j. r yo sr.. Date Called: Special Instructions: Date Wanted: ©j' ? jj ff L 0a.r p.m. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: YA, U.\ Date: 01 Jlily Inspector: / `�,jfkik r REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. 0511 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: t. /� Type of Inspection: ��ce Address: 6 yto 5. .18 d 5 i Date Called: Special Instructions: Date Wanted: dio a:mRequester: C�i Phone No: 33..a"r 9? J ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: 417 f') I t f( tAl r 40Jc pf- Inspector: 4 ,J \ r Date: o02o/i f ,f I REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL14-0341 PROJECT NAME: WELLS FARGO SITE ADDRESS: 6847 S 180 ST DATE: 04/14/2014 X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: pu ot-qi Building Division Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 04/15/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) DUE DATE: 05/13/14 Approved with Conditions171 Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 NELSON ELECTRIC INC Page 1 of 2 Washington State DeparWien! of / Labor & Industries NELSON ELECTRIC INC Owner or tradesperson NELSON, MARVIN D Principals NELSON, MARVIN D NELSON, LYLE D UNDSETN, MARK A NELSON, LAURA NELSON, MARVIN D, AGENT 9620 STONE AVE N STE 201 SEATTLE, WA98103 206-523-4525 KING County License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor License specialties GENERAL License no. NELSOEI132CZ Effective — expiration 02/09/1987— 02/12/2015 Designated administrator Heeb, Brian License type Electrical Administrator Bond CONTINENTAL CASUALTY CO Bond account no. 124082050 Insurance No insurance accounts during the previous 6 year period. Savings No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. Active. Meets current requirements. Active. Meets current requirements. License no. HEEB*B*912K8 $4, 000.00 Effective date 02/01/1994 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600047709&LIC=NELSOEI 132CZ&SAW= 04/29/2014