Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL14-0465 - LULULEMON - LIGHTING AND WIRING
LULULEMON 21 SOUTHCENTER MALL EL1 4-0465 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 9202470130 21 SOUTHCENTER MALL Project Name: LULULEMON ELECTRICAL OTC PERMIT Permit Number: EL14-0465 Issue Date: 8/20/2014 Permit Expires On: 2/16/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, CA, 92013 MELANI DANNENBERG 20521 EARL ST , TORRANCE, CA, 90503 BLACK SHEEP ELECTRIC LLC 4320 196TH ST SW #138, LYNNWOOD, WA, 98036 BLACKSE924JB Phone: (310) 263-3587 Phone: (206) 852-2468 Expiration Date: DESCRIPTION OF WORK: PROVIDE LIGHTING, GENERAL POWER, LOW VOLTAGE AND ALL ASSOCIATED CIRCUITING/WIRING FOR COMPLETE TENANT FIT OUT Valuation of single family: $0.00 Valuation of mf/comm: $40,000.00 Type of Work: TENANT IMP Fees Collected: $842.94 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature. Print Name: Date: g'Za IiY This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB 0014.. CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. 1 L " 64 tsb Project No. Date Application Accepted: I i Date Application Expires: 111 or op ce use on ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 21 SOUTHCENTER m �LL Tenant Name: LULULEMON King Co Assessor's Tax No.: _ ` 2. t 1 "OE ° Suite Number: 748 Floor: 1st PROPERTY OWNER Name: WESTFIELD, LLC Address: 2800 SOUTHCENTER City: SEATTLE State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: MELANI DANNENBERG Address: 20521 EARL ST City: TORRANCE State: CA Zip: 90503 Phone: (310) 263-3587 Fax: (775) 766-9742 Email: New Tenant: ❑ Yes ® ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: T.B.D. Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 40,000 Scope of Work (please provide detailed information): Provide lighting, general power, low voltage and all associated circuiting/wiring for complete tenant fit out. Will service be altered? 0 Yes © No Adding more than 50 amps? ❑ Yes ✓❑ No Type of Use: MERCANTILE Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel m Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: 0 Puget Sound Energy ❑ Seattle City Light H:\Applications\Porms-Applications On Line\2013 Applications\Electrical Permit Application Revised 7-1-13.docx Revised: July 2013 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $65.00 ❑ Temporary service (generator) $80.90 ❑ Manufactured/mobile home service $86.25 (excluding garage or outbuilding) ❑ Carnivals $80.60 Number of concessions $10.80 ea Each ride and generator truck $10.80 ea PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: 044 /0(iLiff Date: "J/ 3II"I Print Name: MELANI DANNENBERG Day Telephone: (310) 263-3587 Mailing Address: 20521 EARL ST, TORRANCE, CA 90503 City H:Wpplications\Forms-Applications On Line\2013 Applications\Electrical Permit Application Revised 7-1-13.docx Revised: July 2013 bh State Zip Page 2 of 2 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $3,237.04 D14-0150 Address: 21 SOUTHCENTER MALL Apn: 9202470130 $2,092.04 DEVELOPMENT $2,092.04 PLAN CHECK FEE R000.345.830.00.00 $2,087.54 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 EL14-0465 Address: 21 SOUTHCENTER MALL Apn: 9202470130 $842.94 ELECTRICAL $802.80 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 $802.80 TECHNOLOGY FEE $40.14 TECHNOLOGY FEE R000.322.900.04.00 $40.14 M14-0103 Address: 21 SOUTHCENTER MALL Apn: 9202470130 $125.18 MECHANICAL $125.18 PLAN CHECK FEE R000.322.102.00.00 $125.18 PG14-0080 Address: 21 SOUTHCENTER MALL Apn: 9202470130 $176.88 PLUMBING $176.88 PLAN CHECK FEE R000.322.103.00.00 $41.88 PERMIT FEE TOTAL FEES PAID BY RECEIPT: R2124 R000.322.100.00.00 $135.00 $3,237.04 Date Paid: Wednesday, May 14, 2014 Paid By: MENEMSHA DEVELOPMENT GROUP Pay Method: CHECK 013245 Printed: Wednesday, May 14, 2014 2:16 PM 1 of 1 r11 SYSTEMS 5- INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: i L� 4frI o Type of Inspection:/4- Address: n ( _ l�� j '� Date Called: t Special Instructions: Date Wanted: j O L�Z- a m Requester: Phone No: Approved per applicable codes. Q Corrections required prior to approval. COMMENTS: Inspector: jtfi T Date: W2414 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPE TION N0. P RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431-2451 (206) 431-3670 Project:W t !� J Type of Inspection: h/V.410., Address:' 1 �t -i(y�/ 2- 44M, Date Called: Special Instructions: `1lKn�Y l' i Date Wanted: /Q/Z1i a:m m. Requester: ► Phone No: la c Approved per applicable codes. EaCorrections required prior to approval. COMMENTS: — Q 1 i wNbrt. S tA'cri ec4JPn L a,Jt R k-r Go A h 6-745 +t # 2. — S +/t a Rt c.OTi ( 4 Fc. i niQ T- R)4C.'loesb rik . Wili-ef s"ir : 4 O ( c (ttArr — )4,0. 5'64-.._ EOgt aJ SPe-via .. " Soy - 1,046,, SG.t4c-Pv hit1Nriecidti ,Jor CAiLCft Inspector: < /t d6 Date: �a/ZI� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD,, Retain a copy with permit]' v (oi ik) INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Type of Inspection: / Address: 2- / //AA,' Date Called: Special Instructions:, Date Wanted: ,. . o�t'5 a.m. p., Requester:� t It 7i4 a/ Phone No: ! Z 5- 2,4 ' fir/ Approved per applicable codes. Corrections required prior to approval. COMMENTS: A J y1, A - ` .. / ocic i s`f urT r q� I i i ` ok-14f X PrP t1— kiCIP ilbl/- n Inspector: y'%tiV Date: O b c1, i REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Z INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 (f-f q— cf& Project: I J Type of Inspection: 0 / Address: 2-1 ` Date Called: Special Instructions: Date Wanted: (0�/3 amp Requester: tily Phone No: 76��f Zb 7 Approved per applicable codes. Corrections required prior to approval. COMMENTS: — t i (O (r %I)V t i 5 e./fro21— fq-A. tL Inspector: Date: /0/ 4( REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. UL1- OL1b 11( CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 . INSPECTION RECORD Retain a copy with permit PERMIT NO. Project: Type of Inspection: Address: c Date Called: ,1 Special Instructions: Date Wanted: rr` bti--� Requester: Phone No: 110-5- 31L1— \ \ 1 ElApproved per applicable codes. O Corrections required prior to approval. COMMENTS: t S 1) Sl sicx4-( ri Inspector: -.fin r) / (6 Date: v 7/ttVr y it REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. r 2012 Washington State P 'gy Code Compliance Forms for Commercial, ( p R1, and > 3 story R2 and R3 Anterior Lighting S mary 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 LGT-SUM Revised June 2013 Project Info Project Address Lululemon Athletica Date 4/25/2014 21 Southcenter, Suite 748 Tukwila, WA 98188 Applicant Name: Randall A. Nelson ApplicantAddress: 14817 West 95th Street, Leneza, RS 66215 Applicant Phone: 913-322-5150 For Building Department Use FTLF CfDX Project Description ❑ New Building ❑ Addition ❑ Alteration ❑ Plans Included Lighting Compliance Path Interior Lighting Compliance Option Interior Lighting System Description Briefly describe lighting system type and features. Q Lighting Power Density Calculations 0 Total Building Performance (If Total Building Performance then only LGT-CHK is required.) 0 Building Area Method Additions and Change of Space Use (C101.4.3 & C101.4.4) Q Space -by -space Method ❑ Addition area or Change of Space Use area complies with all applicable provisions as stand alone ❑ Addition area or Change of Space Use area is combined with existing building lighting systems to demonstrate compliance with all applicable provisions Provide Building Area Method (LTG-INT-BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum allowed and proposed (including existing if applicable) lighting wattage of Addition or Change of Use scope. Provide applicable lighting controls per C405.2 and commissioning of lighting controls per C405.13. Alterations, Renovations and Repairs (C101.4.3.1) Q 60% or more of luminaires in space replaced Provide Building Area Method (LTG-INT-BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum allowed and proposed (including existing) lighting wattage of project scope ❑ Less than 60% of luminaires in space replaced Provide Space -by -space Method (LTG-iNT-SPACE) Compliance Form. Document existing total wattage in space and proposed (including existing) lighting wattage of project scope ❑ Lamp and/or ballast replacement within existing luminaires only — existing total interior building wattage not increased ❑ New wiring installed to serve added fixtures and/or fixtures relocated to new circuit Provide applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific application controls (C405.2.3), and commissioning of lighting controls per C405.13 ❑ New or moved lighting panel Provide all applicable lighting controls as noted for New Wiring, automatic time switch controls (C405.2.2.1), and commissioning of lighting controls per C405.13. Space is reconfigured - luminaires unchanged or moved only Provide all applicable lighting controls as noted for New Wiring and commissioning of lighting controls per C405.13. No changes are being made to the interior lighting and space use not changed. U'4OM lig LTG-INT-SPACE 2012 Washington State -orgy Code Compliance Forms for Commercial, ip R1, and > 3 story R2 and R3 Interior Lighting Sui-nmary - Space -by -Space 2012 Washington State Energy Code Compliance Forms for Commercial Group R1 and > 3 sto R2 and R3 Project Info ry Project Address Lululemon Athletica Revises June 2U13 Date 4/25/2014 21 Southcenter, Suite 748 For Building Department Use Tukwila, WA 98188 Applicant Name: Randall A. Nelson Maximum Allowed Lighting Wattage 0 Location (plan #, room #, or ALL) Space Type* Allowed Watts per ft2 Gross Interior Area in ft2 Watts Allowed (watts/ftz x area) Sales Area Retail: Sales area 1.68 2042 3431 Fitrooms Retail: Dressing/fitting area 0.87 455 396 Office Office - Enclosed 1.11 59 65 Restroom Restroom 0.98 78 76 Staff Area Lounge recreation 0.73 153 112 Stock Room Storage 0.63 281 177 Atrium** Enter Height: Retail Display Allowance from LGT-INT-DISPLAY 3359 Select Table C405.5.2(2) category from drop down menu. ** For atriums, indicate height.Allowed wattage for first 40 feet is 0.03 W/ft. ht., above 40 feet is 0.02 W/ft. ht. Proposed Lighting Wattage Total Area Allowed Watts 3068 7616 Location (plan #, room #, or ALL) Fixture Description (Include exempt equipment per Note 3) Number of Fixtures Watts/ Fixture Watts Proposed Fitrooms LED-F - LED Fitroom Wall Wash 103 3 309 Fitrooms LED -FM - LED Fitroom Wall Wash 27 6 162 Sales Area 1 4 4 Restroom D6 - Above Mirror 23W CFL 1 27 27 Sales Area D7 - Quill Vintage Platinum 2 24 48 Stock Room F4 - 4' Fluorescent Strip 1 32 32 Stock Room F8 - 8' Fluorescent Strip 4 62 248 Restroom FL - Fan Light Combo Unit 2 38 76 Sales Area HB - LED High Bay 10 38 380 Sales Area RA3 - 3 Light Adjustable Down Light 2 63 126 Sales Area RF3 - LED Down Light - 19 29 551 Staff / Office RF4 - LED Down Light 6 12 72 Stock Room CL6 - LED Down Light 1 29 29 Sales Area Retail Display. Lighting from LGT-INT-DISPLAY '` .•. ? *,^.,- 3960 Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 6024 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank. LTG-INT-DISPLAY 2012 Washington State F--rgy Code Compliance Forms for Commercial, up R1, and > 3 story R2 and R3 Interior Display Li ing - Space -by -Space 2012 Washington State Energy Code Compliance Forms for Commercial Group R1 and > 3 sto R2 and R3 Project Info Project Lululemon Athletica Rewsea June 2013 Date 4/25/2014 21 Southcenter, Suite 748 For Building Department Use Tukwila, WA 98188 Applicant Name: Randall A. Nelson Maximum Allowed Display Lighting Wattage Location (plan #, room #, or ALL) Space Type* Allowed Watts per ft2** Gross Interior Area in ft2 Watts Allowed (watts/ft2 x area) Sales Area Retail 3: furniture, clothing, cosmetics, artwork 1.40 2042 2859 n y areas wrth�n retail sales areas that con am separately controlled display light may be entered per Table C405.5.2(2) footnoteA. ** From Table C405.5.2(2) footnote A. Proposed Display Lighting Wattage Only separately controlled display fixtures com Total Area Area Watts 2042 Display Allowance 2859 3359 Location (plan #, room #, or ALL) Display Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Sales Area TL1/TL3 - Track Lighting 1 3960 3960 Total Proposed Watts 3960 Notes: 1. For proposed Display Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all display fixtures. 2012 Washington State - gy Code Compliance Forms for Commercial, ' ip R1, and > 3 story R2 and R3 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1 and > Project Info - �••� • -� Project Address Lululemon Athletica mtviseu uune zu is Date 4/25/2014 21 Southcenter, Suite 748 For Building Department Use Tukwila, WA 98188 Applicant Name: Randall A. Nelson Do Not Enter Lighting Here. Use LTG-INT-SPACE Building Area Location (plan #, room #, or ALL) Area Description Allowed Watts per ft2 * Gross Interior Area in ft2 Watts Allowed (watts/ft2 x area) * Lighting Power Allowances per Table C405.5.2(1) Total Do Not Enter Lighting Here. Use LTG -I Building Area Location (plan #, room #, or ALL) Fixture Description (Include exempt equipment per Note 5) Number of Fixtures Watts/ Fixture Watts Proposed Notes: 1. Proposed Wattage for each Building Area type shall not exceed the Allowed Wattage for that Building Type. Trading wattage between Building Area types is not allowed under the Building Area Method compliance path. 2. Proposed fixtures must be listed in the building area in which they occur. Include ALL fixtures. 3. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 4. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 5. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank. 2012 Washington State . gy Code Compliance Forms for Commercial, Ip RI, and > 3 story R2 and R3 Exterior Lighting Summary 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1 and > 3 story R2 and R3 LTG-EXT Project Info Proj Addres:Lululemon Athletica Revised June 2013 Date 4/25/2014 21 Southcenter, Suite 748 For Building Department Use Tukwila, WA 98188 Name: Randall A. Nelson Appl. Name 14817 West 95th Street, Leneza, KS 66215 Appl. PhonE 913-322-5150 Project Description ❑ New ❑ Addition Alteration ❑ Plans Included Lighting Zone (as specified by Jurisdiction) 0 Zone 1 Zone 2 Q Zone 3 Q Zone 4 Compliance Option ® Lighting Power Density Calculations 0 Total Building Performance Building Grounds > 100 ❑ Efficacy> 60 lumens/W ❑ Controlled by motion sensor (luminaires Watts) Exemption (list) Alteration Exceptions 4 No changes are being made to the exterior lighting (check appropriate box - sec. C101.4.3.1) ❑ New wiring installed to serve added fixtures and/or fixtures relocated to new circuit Provide applicable exterior lighting controls (C405.2.4) and commissioning of lighting controls per C405.13 Tradable Maximum Allowed Lighting Wattage Base Site Allowance: 500 Tradable Surfaces Description Allowed Watts per ft2 or per If Area (ft2), perimeter (If). or # of items Allowed Watts x ft2 (or x If) Total Allowed Tradable Watts: Trarlah1P Prnrwnccwi T ;nl,41-;.. W g attage (use mtgr listed maximum input watta Surface Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Front Canopy Wall Sconce 1 32 32 Total proposed tradable watts may not exceed the sum of total allowed tradable watts plus Total Proposed Tradable Watts: the base site allowance. Any base site allowance not needed to make tradable watts r omnty 32 b can e applied to individual non -tradable categories. • • . vat- i Lauctuic lvid11 uu Eiuowed L umighting wattage Base Site A lowance Remaining: 468 Non -Tradable Surfaces Description Allowed Watts per ft2 or per If Area (ft2), perimeter (If) or # of items Allowed Watts x ft2 (or x If) 'AT es..._T.....7..1,1.. D__---_ _1 r - 1 ng Wattage. Surface Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Non -tradable proposed watts may not exceed allowed watts for any individual surface unless the total excess watts for all non -tradable surfaces are less than the remaining site allowance. Total excess Non -Tradable watts: Site Allowance Balance: 0 0 2012 Washington State R1, and > 3 story R2 and R3 Lighting, Motor, anti Transformer Permit Plans Checklist LTG-CHK 2012 Washington State Energy Code Compliance Forms for Commercial, Group RI, and > 3 story R2 and R3 Project Address y Code Compliance Forms for Commercial, Lululemon Athletica p Revised June 2013 'Date 4/25/2014 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2012 Washington State Nonresidential Energy Code. Applicability I Code (yes, no, n.a.) Section Component Information Required LIGHTING CONTROLS (Section C405.2) Yes Yes Yes Yes C405.2.1 Manual lighting controls Lighting control schedule with type, locations served, 50% lighting reduction method Location Building Department on Plans I Notes E012, E120 C405.2.2.1 Automatic time switch controls Lighting systems automatic shut-off capability - indicate method and location served on plans. Note locations where automatic shutoff is provided by other method (occupancy sensor, daylight controls, etc) E012, E120 N.A. N.A. No C405.2.2.2 Override switching Occupancy sensors Schedule with locations served - no single override switch exceeds an area of 5,000 SF Schedule of locations served E012, E120 E120 C405.2.2.3 Daylight zones Vertical fenestration Primary and secondary daylight zone areas indicated on plans N.A. Yes Yes Yes 405.2.2.3.: C405.2.3 Skylights Daylight zone controls Skylight daylight zone areas indicated on plans Specific application controls Lighting control schedule with dimming method and locations served - no single daylight control zone exceeds 2,500 SF Specific application lighting controls are independent of general area lighting and controls for other lighting applications E012, E120 Means of egress lighting Lighting control schedule with method and locations served. Note luminaires that function as both normal and egress. E120 N.A. N.A. N.A. Yes Yea Display lighting Lighting control schedule with type and locations served E012, E120 Accent lighting Lighting control schedule with type and locations served C405.2.4 Hotel/motel guest rooms Supplemental task lighting Lighting control schedule with type and locations served Non-exempt lighting equipment Non-exempt lighting equipment Exterior lighting controls INTERIOR LIGHTING P Lighting control schedule with type and locations served Lighting control schedule with type, applications served and locations Lighting control schedule with type, applications served and locations Lighting control schedule with type, features and location served E012, E120 E012, E120 E012 Yes C405 5 1 Total connected lighting power Schedule with fixture types, lamps, ballasts, watts per fixture E120.1 N.A. Space exceptions Space exceptions taken noted on plans or compliance form N.A. Lighting equipment exceptions Equipment exceptions taken noted on plans or compliance form Yes C405.5.2 Lighting power calculations No Building Area Method Compliance form completed — proposed wattage per building area does not exceed maximum allowed wattage Yes Space -By -Space Method Compliance form completed — total proposed wattage does not exceed maximum allowed wattage Yes PYTFRIflD I C405.4 I!`uTIklf Exit signs onuin I ._ _., _ __ All internally illuminated exits sign are < 5 watts per side ....,._ _. E120.1 Yes N.A. C405.6.2 Total connected lighting power Exterior application exceptions Schedule with fixture types, lamps, ballasts, watts per fixture Exterior application exceptions taken noted on plans or compliance form E120.1 Yes N.A. C405.6.1 Lighting power calculations Exterior building grounds lighting Compliance form completed — proposed wattage for exterior lighting plus base site allowed does not exceed max. allowed Schedule with fixture types, lamps, ballasts, watts per fixture; lumens per watt for fixtures > 100 watts • 2012 Washington State E ay Code Compliance Forms for Commercial, p R1, and > 3 story R2 and R3 - g, ' o or, an. rans ormer Permit Plans Checklist LTG-CHK 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Address Lululemon Athletics Date 4/25/2014 The following information in the 2012 Washington is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes ELECTRICAL POWER SYSTEMS (Sections C405.7 ,C405.9, C405.12, C409.2.1) N.A. C409.2.1 Electrical energy consumption — whole building Meters provided for whole building electric energy usage N.A. C405.7 Electrical energy consumption — dwelling units Individual dwelling unit electricity meters provided N.A. C405.9 Transformers Indicate transformer size and efficiency on plans N.A. C405.12.1 Variable speed escalators and moving walks Variable speed controls provided N.A. C405.12.2 Regenerative drives Variable frequency regenerative drives provided for escalators COMMISSIONING (Sections C405.13, C408.3, C409.4.4) N.A. C405.13 Commissioning Commissioning procedure developed for all a applicable systems N.A. C408.3 Lighting controls Commissioning plan and functional test procedure developed N.A. C409.4.4 Electrical energy consumption meters Commissioning plan and functional test procedure developed Escalators & moving walks Commissioning plan and functional test procedure developed ion, provide explanation: HERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL14-0465 DATE: 05/14/2014 PROJECT NAME: LULULEMON SITE ADDRESS: 21 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: (l.� og"��t Building Division le Public Works Fire Prevention Planning Division n Structural Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 05/15/14 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 06/12/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping 0 PW ❑ Staff Initials: 12/18/2013 BLACK SHEEP ELECTRIC LLC Page 1 of 2 CilWashington State Department of Labor & Industries BLACK SHEEP ELECTRIC LLC Owner or tradesperson POHLMAN, RYAN C Principals POHLMAN, RYAN C, PARTNER/MEMBER Doing business as BLACK SHEEP ELECTRIC LLC WA UBI No. 602 310 408 PMB #138 LYNNWOOD, WA98036 206-852-2468 SNOHOMISH County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor License specialties GENERAL License no. BLACKSE924JB Effective — expiration 04/02/2008— 04/10/2016 Designated administrator POHLMAN, RYAN C License type Electrical Administrator Bond Old Republic Surety Co Bond account no. YLI0262119 Received by L&I 10/30/2006 Savings No savings accounts during the previous 6 year period. License Violations Infraction no. ETAML00218 Violation date Active. Meets current requirements. Active. Meets current requirements. License no. POHLMRC921 JN $4, 000.00 Effective date 10/28/2006 Expiration date Until Canceled Satisfied RCW/WAC https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602310408&LIC=BLACKSE924JB&SAW= 08/20/2014 SEPARATE PE irr REQUIRED FOR: M©ahanical Electrical Plumbing Gas Piping City of Tukwila I BUILDING DIVISION REVISIONS NO Changes shall be made to the scope of work without prior approve„1 of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. ELECTRICAL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION ABBREVIATIONS $ SINGLE POLE WALL SWITCH Di DISCONNECT SWITCH A AMP 2$ WALL SWITCH - DESIGNATIONS AS FOLLOWS: 60/3 = 60 AMP SWITCH, 3 POLE AC ABOVE COUNTER 2=2 POLE 4=4-WAY 60/3/40 = 60 AMP SWITCH, 3 POLE, 40 AMP FUSE AFF ABOVE FINISHED FLOOR 3=3-WAY P=PILOT LIGHT AFC AVAILABLE FAULT CURRENT M=MOTOR RATED SWITCH H=LIGHTED HANDLE SWITCH AFG ABOVE FINISHED GRADE ELTIME DM=DIMMER TS=TIMER (REFER TO PLANS) AIC AMPS INTERRUPTING CURRENT WALL TYPE OCCUPANCY SENSOR CONTACTOR BRKR BREAKER C CONDUIT m E os CEILING TYPE OCCUPANCY SENSOR PHOTO CELL EC ELECTRICAL CONTRACTOR d) SIMPLEX RECEPTACLE - NEMA 5-20R UNLESS NOTED OTHERWISE EM,EMER EMERGENCY L LIGHT FIXTURE - REFER TO LIGHT FIXTURE SCHEDULE FOR MORE EXIST,EX EXISTING 6 DUPLEX RECEPTACLE - NEMA 5-20R UNLESS NOTED OTHERWISE INFORMATION a - INDICATES SWITCHING SCHEME. CONNECT LIGHT FIXTURE TO G GROUND GFCI GROUND FAULT CIRCUIT INTERRUPTER l 1 Oa * DOUBLE -DUPLEX RECEPTACLE - NEMA 5-20R UNLESS NOTED OTHERWISE �` SWITCH "a". EXIT SIGN - CEILING/WALL MOUNTED, ARROWS AS INDICATED - IG ISOLATED GROUND K KELVIN NL NIGHT LIGHT 6 GFCI RECEPTACLE DESIGNATIONS AS FOLLOWS: GFCI=GROUND FAULT INTERRUPTER WP=WEATHERPROOF REFER TO LIGHT FIXTURE SCHEDULE FOR MORE INFORMATION MCB MAIN CIRCUIT BREAKER MLO MAIN LUG ONLY S=SWITCHED E=EMERGENCY POWER '61--P EMERGENCY BATTERY PACK LIGHT FIXTURE - REFER TO LIGHT P POLE IG=ISOLATED GROUND AC=ABOVE COUNTER FIXTURE SCHEDULE FOR MORE INFORMATION PART PARTIAL CIRCUIT H=HORIZONTALLY MOUNTED PC PHOTOCELL HEAVY DUTY RECEPTACLE - NEMA TYPE AS NOTED ON PLANS. ,---'.' LOW VOLTAGE WIRING PNLBD PANELBOARD RCPT RECEPTACLE FLOOR MOUNTED DUPLEX RECEPTACLE RTU ROOF TOP UNIT 5g ® CEILING MOUNTED DUPLEX RECEPTACLE CONDUIT RUNS ARE SHOWN ON POWER PLANS FOR CLARITY: AS FOLLOWS: TS TIMESWITCH TYP TYPICAL # QUAD RECEPTACLE A-1 CIRCUIT DESIGNATIONS A-1 SINGLE PHASE CIRCUIT. CONNECT TO PANELBOARD UNO UNLESS NOTED OTHERWISE V VOLT g SPECIAL PURPOSE RECEPTACLE. REFER TO PLANS FOR MORE A, CIRCUIT #1 WITH (1) HOT/SWITCH LEG, (1) VA VOLT/AMPERE INFORMATION. NEUTRAL, AND (1) GROUND* W WIRE 8 ABOVE COUNTER DUPLEX RECEPTACLE - NEMA 5-20R UNLESS NOTED WP WEATHERPROOF OTHERWISE JUNCTION BOX A-3,5 TWO PHASE CIRCUIT. CONNECT TO PANELBOARD A, CIRCUIT #3,5 WITH (2) CONDUCTORS AND (1) ®o ® CONNECTION POINT EQUIPMENT GROUND. PROVIDE NEUTRAL AS REQUIRED PER EQUIPMENT. TELEPHONE OUTLET p TELEPHONE/DATA OUTLET A-7,9,11 THREE PHASE CIRCUIT. CONNECT TO PANELBOARD A, CIRCUIT #7,9,11 WITH (3) CONDUCTORS AND (1) p DATA OUTLET GROUND. PROVIDE NEUTRAL AS REQUIRED PER _ ELECTRICAL. PANELBOARD - SURFACE AND RECESSED MOUNTED 'EQUIPMENT. PLYWOOD TELEPHONE TERMINAL BOARD (4'x8'x3/4" UNO) REFERENCE PANELBOARD SCHEDULES FOR WIRE SIZES ALL CONDUIT WIRELESS ACCESS POINT SHALL HAVE EQUIPMENT GROUND WIRE. PROVIDE ISOLATED GROUND WIRE WHERE 'INDICATED. *3-WAY AND 4-WAY SWITCHING REQUIRES ADDITIONAL CONDUCTORS FOR PROPER OPERATION. PROVIDE AS REQUIRED FOR A COMPLETE WORKING LIGHTING CONTROL SYSTEM. PROVIDE UN -SWITCHED HOT TO ALL EMERGENCY LIGHTING FIXTURES AND EXIT SIGNS. LC3 LC3 LC3 EM,LC2 EM,LC2 LC1 LC1 LC2 EM,LC2 LC1 EM,LC2 LCK LC1 LC1 LC3 LC3 REVIEWED FOR COMPLIANCE WITH NPPA70-NEC MAY 2 3 2014 ^r City of T ila BUILDING D SION NOTE: VOLTAGE DROP CALCULATIONS AND AVAILABLE FAULT CURRENT CALCULATIONS IS BASED ON THE FOLLOWING ASSUMPTIONS. • CONDUCTOR LENGTH BETWEEN PANELBOARD LANDLORD PROVIDED 208Y/120V, 3PH, 4W, ELECTRICAL SERVICE OF 100' WITH #3/0 W • 65,000A AVAILABLE FAULT CURRENT. AT THE POINT TO LANDLORD PROVIDED. 208Y/120V, AMP ELECTRICAL SERVICE. 'L'AND TO 200 AMP IRE. CONNECTION 3PH, 4W, 200 CONTRACTOR TO FIELD VERIFY ALL ASSUMPTIONS LISTED AND ALERT ARCHITECT/ENGINEER IF ACTUAL INFORMATION DIFFERS. FILE COPY Permit No., UC Plan review approval is subject to errors and omleel ns Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Held Copy and conditions Is acknowledged: BY City Of BuIi.DING DIVISION COMMERCIAL LOAD SUMMARY BUILDING AREA: 3,068 SQ. FT VOLTAGE: 208Y 120V, 3PH, 4W LOAD DESCRIPTION CONNECTED LOAD (VA) DEMAND FACTOR DEMAND LOAD (VA) LIGHTING POWER & INTERIOR LIGHTING 5,237 x 125% = 0 EXTERIOR LIGHTING 572 x 125% = 715 SIGNAGE 2,400 x 125% = 3,000 MINIMUM GENERAL LIGHTING PER NEC-220 x 125% 11,505 MINIMUM TRACK LIGHTING/SHOW WINDOW PER NEC-220 x 125% 24,781 HVAC EXISTING 0 x 100% = 0 RECEPTACLES 4,140 x 100%; 50% = 4,140 MISCELLANEOUS EQUIPMENT 4,150 x 100% = 4,150 REFRIGERATION EQUIPMENT 900 x 100% = 900 KITCHEN 0 x 100% = 0 HVAC - SUMMER ' 13,500 x 100% = 13,500 HVAC - WINTER 0 x 100% = 0 SUPP. ELECTRIC HEP.T 4,080 x 100% = 4,080 MOTORS 1,500 x 100% = 1,500 LARGEST MOTOR 500 x 25% = 125 SUB -TOTAL (VA) SUB -TOTAL (AMPS) 36,979 SUB -TOTAL (VA) SUB -TOTAL (AMPS) SERVICE SIZE (AMPS) CAPACITY (AMPS) - 68,396 103 190 SPARE° 200 10 PANELBOARD L ` BUS AMPS: 225A LOCATION: MAIN SIZE / TYPE:GiDoA- •i99ik+MCB 1 NEMA RATING: VOLTS/PHASE: 208Y/120V, 3 4W AFC VALUE: MOUNTING: RECESSED AIC RATING: BACK OF HOUSE GROUND BUS: YES NEMA 1 ISOL. GROUND BUS: YES 12,466A FEED THRU LUGS: NO 22,000A FULLY RA, SECTIONS: 1 OF 1 CKT # CIRCUIT DESCRIPTION BREAKER WIRE SIZE LOAD (VA) CONNECTED PER PHASE (VA) LOAD (VA), WIRE SIZE BREAKER CIRCUIT DESCRIPTION CKT ,# AMPS P A B C P AMPS 1 SHOW WINDOW LTG 20 1 12 126 486 36� _ 12 1 20 CASHWRAP IG QUAD RCPT 2 3 SHOW WINDOW RCPT 20 1 12 540 900 :-' 360 %12 1 20 CASHWRAP IG RCPT 4 5 SIGNAGE 20 1 12 1,200 1,560 ;360 x ;1 20 BACKWRAP RCPT 6 7 GENERAL SALES / EM LIGHTING 20 1 12 402 762 360 12 1 20 MANAGER'S DESK RCPT 8 9 GENERAL SALES / EM LIGHTING 20 1 12 182 1,102 920 12 120 STAFF RCPT 10 11 TRACK DISPLAY LTG 20 1 12 432 1,632 °' 1,200 j 12 1 20 MICROWAVE RCPT 12 13 TRACK DISPLAY LTG 20 1 12 936 1,836 ' ' 900 12 1 20 REFRIGERATOR RCPT 14 15 FITTING ROOM LIGHTING 20 1 12 471 971 500 12 1 20 SERVER CABINET RCPT 16 17 FITTING AREA / EM LIGHTING 20 1 12 348 548 200 12 1 20 SECURITY SYSTEM 18 19 DISPLAY / PENDANT LIGHTING 20 1 12 66 426 36C 12 1 20 SENSORMATIC 20 21 STOCK / RR / OFFICE / EM LTG 20 1 12 422 782 360 12 1 20 TELEPHONE BOARD RCPT 22 23 TIME SWITCHES / CONTACTORS . 20 1 12 250 670 420 12 1 20 PRINTER / OFFICE RCPT 24 25 WH-1 30 1 10 2,500 3,100 600 12 1 20 MUSIC SYSTEM RCPT 26 27 TRACK DISPLAY LTG 20 1 12 964 964 0 1 20 SPARE 28 29 TRACK DISPLAY LTG 20 1 12 888 1,608 720 12 1 20 SALES FLOOR RCPT 30 31 EXTERIOR LTG 20 1 12 32 272 240 12 1 20 WATER FEATURE 32 33 SIGNAGE 20 1 12 1,200 2,100 900 12 1 20 STOCK ROOM / RESTROOM RCPT 34 35 SPARE 20 1 0 1,400 1,400 12 1 20 HAND DRYER 36 37 SPARE 20 1 0 0 0 1 20. SPARE 38 39 SPARE 20 1 0 0 0 1 20 SPARE 40 41 SPARE 20 1 0 180 180 12 1 20 PANL WALL RCPT 42 SECTION: 2 43 CU-1 (*) 3 (*) 4,500 4,500 0 1 20 SPARE 44 45 4,500 4,500 0 1 20 SPARE 46 47 4,500 4,500 0 1 20 SPARE 48 49 AHU-1 (*) 3 (*) 500 500 0 1 20 SPARE 50 51 500 500 0 1 20 SPARE 52 53 500 500 0 1 20 SPARE 54 55 CU-.1 SERVICE RCPT 20 1 12 180 180 0 1 20 SPARE 56 57 SPARE 20 1 0 0 0 1 20 SPARE 58 59 SPARE 20 1 0 0 0 1 20 SPARE 60 61 SPARE 20 1 0 0 0 1 20 SPARE 62 63 SPARE 20 1 0 0 0 1 20 SPARE 64 65 SPARE 20 1 0 0 0 1 20 SPARE 66 67 SPARE 20 1 0 0 0 1 20 SPARE 68 69 SPARE 20 1 0 0 0 1 20 SPARE 70 71 SPARE 20 1 0 0 0 1 20 SPARE 72 73 SPARE 20 1 0 0 - 0 1 20 SPARE 74 75 SPARE 20 1 0 0 0 1 20 SPARE 76 77 SPARE 20 1 0 0 0 1 20. SPARE 78 79 SPARE 20 1 0 0 0 1 20 SPARE 80 81 SPARE 20 1 0 0 0 1 20 SPARE 82 83 SPARE 20 1 0 0 0 1 20 SPARE 84 PER PHASE SUB -TOTALS I 12,062 I 11,819 12,598 LEGEND: TOTAL CONNECTED PANELBOARD (VA) TOTAL CONNECTED PANELBOARD (AMPS) TOTAL PANELBOARD DEMAND (VA) TOTAL PANELBOARD DEMAND (AMPS) 36,479 TS - VIA TIME SWITCH ST - SHUNT TRIP GF - GROUND FAULT INTERRUPTER LCK - LOCKING TAB FA - FIRE ALARM / RED / LOCKING TAB IG - ISOLATED GROUND EM - EMERGENCY LTG. / LOCKING TAB OL - RE: ONE -LINE DIAGRAM LC# - VIA LIGHTING CONTACTOR (RE: E012) 101 63,313 176 (*) - HVAC EQUIPMENT PROVIDED BY LANDLORD. LOADS SHOWN ARE FOR REFERENCE ONLY. REFER TO KEYNOTE 6 ON SHEET E110S FOR MORE INFORMATION. • RECEIVED CITY OF TUKWILA MAY 1 4 2014 PERMIT CENTER IG,LCK IG,LCK IG,LCK IG,LCK LCK LCK IG,LCK IG,LCK IG,LCK 0+- (0 5 MEP Engineer of Record Randall A. Nelson, P. E. 14817 West 95th Street Lenexa, Kansas 66215 Phone 913 322 5150 hore ret P o N V z 0 P a. C M DATE -Io Z LL A . 1►r ) Op WAStirr C ~60 , 43448 .9 4 % 45G s R o t EXPIRES 9/21/2015 ELECTRICAL SCHEDULES AND LEGEND LULULEMON ATHLETICA CO\STUCTIO\ STANDADS 21 SOUTHCENTER, SUITE 740 TUKWILA, WA 98188 ISSUE FOR SD 03/24/14 ISSUE FOR DD-LLL 04/15/14 ISSUE FOR DD-LLD 04/18/14 ISSUE FOR CD-LLL 05/01/14 ISSUE FOR CD -LLD 05/01/14 ISSUE FOR PERMIT xx/xx/xx ISSUE FOR BID xx/xx/xx Scale: AS INDICATED Dace: 3/7/14 Drawn By: DP/DB Checked By. CF Job Number: 142.0115 Drawing: LANDLORD ELECTRICAL GEAR TO LANDLORD PROVIDED ELECTRICAL SERVICE. COORDINATE ALL REQUIREMENTS WITH LANDLORD AND OWNER. TENANT SPACE PANEL 'L' 2 SECTION PROVIDE (4)#3/0, (1)#6G AND (1)#6 IG IN 3-1/2" LANDLORD PROVIDED CONDUIT. ROUTE CONDUCTORS BACK TO LANDLORD PROVIDED 208Y/120V, 3PH, 4W, 200 AMP ELECTRICAL SERVICE AND EXTEND CONDUIT AND CONDUCTORS TO LOCATION OF PANELBOARD 'L' AS SHOWN ON PLAN. GROUND LEVEL FIELD VERIFY EXISTING CONDITIONS PRIOR TO BID AND NOTIFY ARCHITECT OR ENGINEER OF ANY DISCREPANCIES. ELECTRICAL RESPONSIBILITY SCHEDULE z 1- w FURNISHED BY INSTALLED BY LANDLORD w z 0 d w 1- 0 LANDLORD w z 0 z1— zz �o 1n w 0 REMARKS FIELD _VERIFY `PRIOR: PANELBOARD CONDUIT TO SPACE METER REQUIREMENTS • • • • • • 4 FIELD VERIFY PRIOR TO BID FIELD VERIFY PRIOR TO BID OUTLETS AND SWITCHES • • TELEPHONE CONDUIT W/ PULL WIRE • • TELEPHONE EQUIPMENT • • CONDUIT INSTALLED ONLY IF REQUIRED BY CODE DATA CABLING • • VIDEO/TVCONDUIT <I VIDEO/TV CABLING • • P.ORARY . UTILITY :CHARG,E TENANT ELECTRICAL PANELS • • ELECTRICAL' ;T RANS FOR M E TENANT FIRE ALARM SYSTEM • • DEFERRED SUBMITTAL BY G.C. FURNISHED_AND ;:INSTALLE BY= :EAS'=VENDOR SENSORMATIC CORE DRILL/TRENCH AND CONDUIT • • ELECTRICAL RISER DIAGRAM SCALE: NTS NOTES: 1. THIS DETAIL IS SCHEMATIC IN NATURE. PROVIDE ALL NECESSARY WIRING, CONDUIT, DEVICES, BOXES, ETC FOR A COMPLETE OPERATING LIGHTING SYSTEM. 2. TIMESWITCHES — TS1—PROVIDE TORK DIGITAL EWZ SERIES, MODEL EWZ201 (2—CHANNEL, SPST). TS2—PROVIDE TORK DIGITAL EWZ SERIES, MODEL EWZ101 (1—CHANNEL, SPST). 3. CONTACTOR — PROVIDE SQUARE D MODEL 8903 ELECTRICALLY HELD CONTACTOR WITH POLE QUANTITY AS INDICATED. 4. 2—HOUR TIMED OVERRIDE SWITCH — PROVIDE PARAGON SWP2H 0-2 HOUR SPRING WOUND INTERVAL TIMED OVERRIDE SWITCH. 5. CURRENT LIMITING PANEL — PROVIDE COOPER GREENGATE TRACKEEPER TK16-120-4—F WITH CIRCUIT BREAKER RATINGS AS INDICATED. PROVIDE 2—HOUR TIMED OVERRIDE SWITCH COORDINATE TIME SCHEDULE WITH OWNER AND LANDLORD (AS REQUIRED). L-23 HOT TS1 •0 L-11 L-13 L-27 L-29 CURRENT LIMITING PANEL 5A PROVIDE NEMA 1 ENCLOSURE SIZED AS NEEDED TO ACCOMMODATE ALL CONTACTORS LC1 10A 10A 8A L-19 LC2 L-7, T REMOTE SWITCH (TYP) /—• RE: DETAIL 3 THIS SHEET RISER DIAGRAM GENERAL NOTES: 1. HVAC CIRCUIT BREAKERS TO BE "HACR" TYPE WHERE REQUIRED BY EQUIPMENT NAMEPLATE PER NEC. 2. FIELD VERIFY EXACT AIC RATING OF LANDLORD'S DISTRIBUTION EQUIPMENT. FURNISH AND INSTALL TENANTS ELECTRICAL SYSTEM TO MATCH AS NECESSARY. 3. BALANCE ALL PANELBOARDS AND ELECTRICAL EQUIPMENT UNDER LOAD CONDITIONS TO +/— 10% BETWEEN PHASES; A/B, B/C, A/C REGARDLESS OF CIRCUITING INDICATED. 4. PROPER CLEARANCE MUST BE MAINTAINED ABOUT ELECTRICAL EQUIPMENT PER NEC. FIELD VERIFY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL ROOM/AREA PRIOR TO INSTALLATION OF ELECTRICAL EQUIPMENT. 5. MAKE ALL FINAL ELECTRICAL CONNECTIONS FOR . A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM. 6. TENANT'S NAME AND SPACE SHALL BE ENGRAVED ON A BAKELITE PLATE WITH 1" HIGH LETTERS. SCREW FASTEN TO THE METER SOCKET AND DISCONNECT SWITCH/CIRCUIT BREAKER AT THE SERVICE DISTRIBUTION P01 NT. 7. ALL CONNECTIONS TO LANDLORD'S SERVICE EQUIPMENT SHALL BE AS DIRECTED BY LANDLORD'S SITE REPRESENTATIVE. PROVIDE ALL TERMINATION EXPENSES. 8. TENANT'S ELECTRICAL SYSTEM SHALL BE GROUNDED TO THE BUILDING'S MAIN GROUNDING SYSTEM. 9. ALL EQUIPMENT TO BE U.L. LISTED OR EQUIVALENT. NEUTRAL SPARE TRACK DISPLAY TRACK DISPLAY TRACK DISPLAY PENDANTS, DISPLAY PENDANTS, DISPLAY SPARE 0110 D f 10 SALES LIGHTING TO EMERGENCY/NIGHT—LITE LIGHTING SALES LIGHTING TO EMERGENCY/NIGHT—LITE LIGHTING D - FITTING AREA TO EMERGENCY/NIGHT—LITE LIGHTING FITTING ROOMS L-90110 L-17 I 0 11 0 I ' L-15 o o L-21 • 0110 o; i T L 1I, L 3• L 5 L-31. L-33 LC3 STOCK ROOM LIGHTING RE: E120 FOR LOCATION TO EMERGENCY/NIGHT—LITE LIGHTING AND OFFICE/RESTROOM/STAFF LIGHTING SPARE SPARE 0110 II II 0-1 I-0 OLIGHTING CONTROL SCHEMATIC SCALE: NTS SHOW WINDOW LTG SHOW WINDOW RCPT SIGNAGE EXTERIOR LTG SIGNAGE SPARE REVIEWED FOR COMPLIANCE WITH PA70-NEC MAY 2 3 2014 City of Tukwila BUILDING DIVISION EL-14-001-1bS NOTES: 1. EACH SWITCH MUST BE LIGHTED TOGGLE TYPE SWITCH, FACTORY WIRED TO ILLUMINATE WHEN LOAD IS ON. PROVIDE NEUTRAL CONNECTION TO EACH SWITCH AS NECESSARY. 2. PROVIDE EACH SET OF SWITCHES IN MULTI —GANG OUTLET BOX WITH SINGLE COVERPLATE. PROVIDE LABEL ABOVE EACH SWITCH WITH DESCRIPTION OF LIGHTING CONTROLLED AS INDICATED. TRACK TRACK TRACK TRACK PENDANTS, DISPLAY DISPLAY DISPLAY DISPLAY CASHWRAP ON a OFF ON OFF ON ON c d OFF OFF ON OFF SALES SALES LTG LTG FITTI N G AREA LTG ON ON ON FITTING ROOM LTG ON f g h j OFF OFF OFF OFF RECEIVED CITY OF TUKWILA MAY 1 ,4 2014 PERMIT CENTER MASTER LIGHTING SWITCHBANK SCALE: NTS MEP Engineer of Record Randall A. Nelson, P. E. 14817 West 95th Street Lenexa, Kansas 66215 Phone 913 322 5150 .I ff: _At L DATE I DESCRIPTION .z 41O� oII�� - WA�l� cJ} 43448 A' rB y9 i `Il1 EXPIRES 9/21/2015 ELECTRICAL RISER AND LIGHTING CONTROLS LETICA STANDADS ISSUE FOR SD 03/24/14 ISSUE FOR DD—LLL 04/15/14 ISSUE FOR DD—LLD 04/18/14 ISSUE FOR CD—LLL 05/01/14 ISSUE FOR CD —LLD 05/01/14 ISSUE FOR PERMIT xx/xx/xx ISSUE FOR BID xx/xx/xx Scale: AS INDICATED Dote: 3/7/14 Drawn By: DP/DB Checked By: CF Job Number: 142.0115 Drawing: DATA TO BE INSTALLED ADJACENT TO POWER AS SHOWN (TYP) DATA AND POWER INSTALLED INSIDE CASH DESK WITH ACCESS FROM THE FRONT CONTRACTOR TO STUB UP POWER AND DATA IN HATCHED AREA. VERIFY EXACT LOCATION IN IELD. (TYP) THESE DETAILS ARE SHOWN FOR REFERENCE ONLY. COORDINATE DEVICE LOCATIONS WITH ACTUAL FURNITURE LAYOUTS. 0 ®. D DATA TO BE NSTALLED ADJACENT TO POWER AS SHOWN (TYP) DATA AND POWER INSTALLED INSIDE CASH DESK WITH ACCESS FROM THE FRONT ELEVATION 3 TILL CASH DESK CONTRACTOR TO STUB UP POWER AND DATA IN HATCHED AREA. VERIFY EXACT LOCATION IN FIELD. (TYP) 0 0 IG SAFE IG V PLAN TH DETAILS ARE SHOWN FOR REFERENCE • LY. ORDINATE DEVICE LOCATIONS WITH ACTUAL FU TURE LAYOUTS. ELEVATION 4 TILL CASH DESK 2 ICASH DESK DETAIL SCALE: NTS POWER GENERAL NOTES: 1. REFER TO MECHANICAL PLAN FOR LOCATION OF MECHANICAL EQUIPMENT.. FIELD VERIFY EXACT LOCATIONS. PROVIDE AND INSTALL ALL CONVENIENCE RECEPTACLES, SAFETY SWITCHES, WIRING, OR OTHER EQUIPMENT TO ENSURE A COMPLETE AND OPERABLE HVAC SYSTEM. ALL CEILING MOUNTED RECEPTACLE COVERPLATES SHALL BE WHITE IN COLOR. ALL WALL MOUNTED RECEPTACLES, AND SWITCHES SHALL BE MOUNTED VERTICALLY AND SHALL BE WHITE IN COLOR. IN THE SALES AREA AND FITTING AREAS, COVERPLATES SHALL BE WHITE. IN THE BACK OF HOUSE, COVERPLATES SHALL BE STAINLESS STEEL. IN THE STAFF AREA ALL RECEPTACLES AND COVERPLATES SHALL BE WHITE. 4. CONDUIT FOR DATA/TELEPHONE OUTLETS SHALL HAVE NO MORE THAN THREE 90' BENDS. IF THE CONDUIT RUN REQUIRES MORE THAN THREE 90' BENDS, PROVIDE A PULL/JUNCTION BOX AFTER EACH SET OF THREE 90' BENDS. LABEL ALL COVERPLATES ON INSIDE FACE OF PLATE WITH CIRCUIT NUMBER AND PANEL DESIGNATION. I.E. "A-1" CIRCUIT SHALL BE WRITTEN WITH PERMANENT MARKER IN A CONTRASTING COLOR. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS OF RECEPTACLES, DATA/TELEPHONE OUTLETS AND OTHER DEVICES. 7. ALL EQUIPMENT SHALL BE U.L. LISTED OR EQUIVALENT. 8. ALL EXPOSED CONDUIT MUST BE RUN STRAIGHT AND PARALLEL/PERPENDICULAR TO STRUCTURE. RUN CONDUIT ADJACENT TO EXISTING STRUCTURE OR ROOF DECK WHERE POSSIBLE. REVIEW ANY QUESTIONS REGARDING INSTALLATIONS WITH LULULEMON CONSTRUCTION MANAGER. SAFE 8 0 ELECTRICAL POWER PLAN KEYNOTES: L1 2 X SW L-3. 1 SW L-3 1 1 STOREFRONT RECEPTACLE: RECEPTACLES AND COVERPLATES WITH AN "SW" DESIGNATION SHALL BE MOUNTED HORIZONTALLY ON CEILING IF CEILING IS WITHIN 18" FROM THE TOP OF THE WINDOW, OR ON THE WALL ABOVE THE WINDOW IF THERE IS MORE THAN 18" TO THE CEILING ABOVE. ROUTE CIRCUIT THROUGH LIGHTING CONTACTOR (RE: 2/E012 FOR MORE INFORMATION). CASH REGISTER: ELECTRONIC CASH REGISTER POWER SYSTEM. THE CIRCUITS USED TO POWER THE ELECTRONIC CASH REGISTERS SHALL NOT BE USED FOR ANY OTHER PURPOSES. THE CIRCUITS SHALL NOT SHARE THE NEUTRAL OR GROUND WITH OTHER EQUIPMENT. SEPARATE POWER, NEUTRAL AND ISOLATED GROUND WIRES, MINIMUM SIZE #12 AWG, SHALL BE RUN TO THE CIRCUIT BREAKER PANELBOARD WHERE GROUND WIRE SHALL BE TIED TO THE GROUND TERMINAL ISOLATED FROM NEUTRAL. DO NOT USE THE CONDUIT FOR GROUNDING AS THIS IS NOT ADEQUATE AT HIGH FREQUENCIES. CIRCUITS FOR THE ELECTRONIC CASH REGISTERS SHALL BE RUN IN SEPARATE CONDUIT. REFER TO DETAIL 2 ON THIS SHEET, AND DETAIL 4, SHEET E510S, FOR MORE INFORMATION. PANELS: ELECTRICAL SERVICE EQUIPMENT, SEE ELECTRICAL RISER DIAGRAM ON SHEET E012 FOR ADDITIONAL INFORMATION. SEE RESPONSIBILITY SCHEDULE ON E012 FOR LANDLORD AND TENANT RESPONSIBILITIES: COMPUTER OUTLET: CONTRACTOR TO COORDINATE WITH MILLWORK VENDOR ON ALL POWER AND DATA OUTLET REQUIREMENTS AT CASH WRAP. PROVIDE CIRCUITING AS SHOWN ON PLAN. REFER TO DETAIL 2 ON THIS SHEET FOR MORE INFORMATION. STEREO POWER: PROVIDE POWER FOR MUSIC STEREO. REFER TO DETAIL 5 ON SHEET E510S FOR MORE INFORMATION. VERIFY FINAL LOCATION WITH OWNER. PROVIDE CIRCUITING TO ALL LANDLORD PROVIDED MECHANICAL EQUIPMENT. CONTRACTOR IS TO VERIFY UNIT NAMEPLATE DATA AND PROVIDE MATCHING CIRCUIT BREAKER AND ASSOCIATED WIRE SIZE PER NAMEPLATE. PROVIDE LOCAL DISCONNECTS AT ALL MECHANICAL EQUIPMENT AND WEATHERPROOF/GFCI CONVENIENCE RECEPTACLE AT OUTDOOR UNITS IF NOT CURRENTLY EXISTING. CONNECT RECEPTACLE TO CIRCUIT L-55. L-32 GFCI L-42 +68" L-30 7. WATER HEATER: TANK TYPE ELECTRIC WATER HEATER - 120V, 1PH, 2,500W. CIRCUIT AS INDICATED. PROVIDE LOCKABLE 30A/1P DISCONNECT SWITCH. 8. FIRE ALARM: A. THE FIRE ALARM SYSTEM SHALL BE A TENANT DESIGN BUILD SYSTEM IF REQUIRED: B. TENANT SHALL OBTAIN THE SERVICES OF LANDLORD AUTHORIZED FIRE ALARM MANUFACTURER TO DESIGN A COMPLETE SYSTEM APPLICABLE TO THIS BUILDING OCCUPANCY IF APPLICABLE. C. THE SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH ALL LOCAL CODES AND NFPA STANDARDS. D. THE AUTHORIZED CONTRACTOR SHALL SUBMIT A COMPLETE SET OF DOCUMENTS TO THE BUILDING DEPARTMENT AND OBTAIN A PERMIT SEPARATE FROM THE ELECTRICAL DOCUMENTS. E. FIRE ALARM SYSTEM TO BE DONE BY LANDLORD REQUIRED SUBCONTRACTOR (DESIGN/BUILD) UNDER CONTRACT WITH TENANT IF APPLICABLE. 9. HAND DRYER: ELECTRICAL ENTRANCE LOCATION OF HAND DRYER AT 22.7" AFF. COORDINATE EXACT LOCATION AND INSTALLATION HEIGHT OF JUNCTION BOX WITH THE PROJECT MANAGER AND PER MANUFACTURER RECOMMENDATIONS PRIOR TO ROUGH -IN. SEE FIXTURE SCHEDULE FOR SPECIFICATION. 10. SENSORMATIC SYSTEM: PROVIDE JUNCTION BOX IN ACCESSIBLE LOCATION ABOVE CEILING FOR POWER TO SENSORMATIC SYSTEM. COORDINATE EXACT LOCATION OF POWER SUPPLY WITH ARCHITECT PRIOR TO ROUGH -IN. PROVIDE ALL CONDUIT AND WIRING FOR A COMPLETE AND FUNCTIONAL SYSTEM. COORDINATE ALL REQUIREMENTS WITH MANUFACTURER PRIOR TO ROUGH -IN. SENSORMATIC SYSTEM MAY NOT BE VISIBLE. 11. NETWORK CABINET: DUPLEX RECEPTACLE REFER TO DETAIL 2 ON SHEET 510S. INSTALL IN BACK OF NETWORK CABINET. PROVIDE CUTOUT IN BACKERBOARD BEHIND NETWORK CABINET AND IN NETWORK CABINET FOR ACCESS TO OUTLET FROM CONCEALED CONDUIT IN WALL. 12. INSTALL JUNCTION BOX AND TRANSFORMER FOR AUTOMATIC FAUCET FURNISHED BY PLUMBING CONTRACTOR. PROVIDE POWER WIRING AND CONNECT TO TRANSFORMER. REVIEWED FOR COMPLIANCE WITH NFPA 70-NEC MAY 2 3 2014 City of Tukwila BUILDING DIVISION - 8 IG I -r GI L- 13 J L-34 ; IT-- -II L-34 GFCI +44" L-25 6,IG L-305__�--_II, ELECTRICAL POWER PLAN SCALE: 1 /4" = 1 '-0" 13. REFER TO ARCHITECTURE PLANS FOR EXACT LOCATION AND INSTALLATION HEIGHT OF RECEPTACLES IN THIS AREA. 14. PROVIDE (2) 3/4" CONDUITS FOR CASH WRAP CIRCUITING INSTALLED IN. OR UNDER THE SLAB AS DIRECTED BY LANDLORD. ROUTE CIRCUITING AS. SHOWN ON PLANS WITHIN CONDUIT, UP TO DECK AND BACK TO PANELBOARD AS REQUIRED. REFER TO SHEET E130 FOR ADDITIONAL LOW LOW CONDUIT AT THIS AREA. 15. PROVIDE USB CHARGER RECEPTACLE, HUBBELL MODEL #USB20X. COLOR OF RECEPTACLE TO MATCH ADJACENT ELECTRICAL DEVICES. L-34 3 (� j r L-22,IG 'L'SEC 2 'L' SEC fl 13 NOTE: INFORMATION ON THIS SHEET PERTAINING TO THE EXISTING ELECTRICAL SYSTEM IS BASED ON RECORD DRAWINGS AND SITE INFORMATION AVAILABLE AT THE TIME OF DESIGN. FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY ARCHITECT AND ENGINEER IMMEDIATELY IF ANY DISCREPANCIES ARE FOUND. EL ()/--( (ps• FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT RECEIVE WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, MINCER TUK OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. MAY 1 1, 20 D w 14 PERMIT CENTER ILA MEP Engineer of Record Randall A. Nelson, P. E. 14817 West 95th Street Lenexa, Kansas 66215 Phone 913 322 5150 1 E d rJ DESCRIPTION M DATE O tiL A A. ,k� oP writ,,. to c tt , i 43448 9 40' o �t Bj 14/1141 EXPIRES 9/21/2015 ELECTRICAL POWER PLAN LLULEVO\ ATHLETICA CO\STUCTIO\ STA\DADS 21 SOUTHCENTER, SUITE 748 TUKWILA, WA 98188 ISSUE FOR SD 03/24/14 ISSUE FOR DD-LLL 04/15/14 ISSUE FOR DD—LLD 04/18/14 ISSUE FOR CD—LLL 05/01/14 ISSUE FOR CD -LLD 05/01/14 ISSUE FOR PERMIT xx/xx/xx ISSUE FOR BID. xx/xx/xx Scale: AS INDICATED Date: 3/7/14 Drawn By: DP/DB Checked. By. CF Job Number: 142 0115 Drawing: RF3 EX1 L-9 L-9 L-33 D4 C L-31 r EX3 L-9 TL1(8)------- L— r.a 27p e •fr TL1(6) L-13 TL1(6) L-13 HB $ $EX1 L-9 I I L-9 TL1(10) L-11 TL1(5) L-13 FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, .ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST: BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. 'II 1 TL1(3 b TL1(3) L-2 L-27 HB L-7 TL1(5) L-29 TL1(3) L-27 a JI RA3-_ . RA3 L-1— L-1. TL1(5) L-29 Al A- A' d—' dJ TL1(11) L-29 EX3 L-7 LEDF LEDF L 15 L 15_\ :; I LEDF' LEDF F L-15 pLEDF L-15 I�` L-15 O RF3 L-17 RF3 LEDF L-15 — LEDFM L-15 RF3 RF3 eft RF3 L-17° L-17 LEDF L-1,6 LEDF L-15 LEDF L-15 RF3EM ®L-17 NL LEDF L-15 LEDF L-15_ RF3 L-17 D7 L-19 O RF3 L-17 LEDF L-15- LEDFM `— LEDF L-15 L-15 RF3 OL-17 LEDFM L-15 RF3 L-170 O RF3 L17 LEDF L.715 LEDF TL1(4) L-11 RF3 L— 7 RF3 L7 EX3 -L-7 EX1 L-7 RF3 L-7 TL1(4) L-29 TL1(4) L-29 RF4 mOL-21 RF4 mOL—1 EX3 FL 0/L-21 L-21 10 2 TL1(4) L-1 1 A' is-1 A' EX3 L-17 12 RLX21 EX3 L1-7 O RF3 L— 7 TL1(2) TL1(2) TL3(2) TL3(2) L-27 L-27 -- • -- '- • I 0 • `.0 A'' A• TL1(8) L-29 HB L-7 — — TYP L-7 • 11 4 i I 4- L-1p a€EX2 CL6/flt —21L—i L 21 Op op \0 EX3 L— 21 TL1(4 L-27 11 5 9 F8EM L-21 NL 1- — _ F8 L-21 p ®p 1 fi 1 p EX3 1_L-21_ TYP 12 r(pRF4 L— 21 F4, _L PI LEDFM '— LEDF L-15 L-15 ELECTRICAL LIGHTING PLAN SCALE: 1/4" = 1'-0 NOTE: INFORMATION ON THIS SHEET PERTAINING TO THE EXISTING ELECTRICAL SYSTEM IS BASED ON RECORD DRAWINGS AND SITE INFORMATION AVAILABLE AT THE TIME OF DESIGN. FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY ARCHITECT AND ENGINEER IMMEDIATELY IF ANY DISCREPANCIES ARE FOUND. ALL LUX BEAM COMPONENTS SHOWN (EXCEPT J—BOX) ARE PROVIDED BY CS ILLUMINATION AIRCRAFT CABLE SUPPORT ONE EVERY. LUX BEAM CONNECTION — EVERY 12' TYP. 12' LUX BEAM 12' —0" 12'—O" LUX BEAM INSTALLATION DETAIL SCALE: NTS J—BOX POWER FEED -- ONE PER 24' $$$$ fghj poi LIGHTING GENERAL NOTES: 1. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF LIGHTING FIXTURES. 2. EMERGENCY AND EXIT LIGHTS SHALL BE INSTALLED AND CIRCUITED PER THE LATEST NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES. ALL EMERGENCY AND EXIT FIXTURES SHALL BE DUAL VOLTAGE (120/277 VOLT INPUT) WITH BATTERY BACKUP. 3 CONTRACTOR IS RESPONSIBLE FOR ALL REFLECTED CEILING PLAN NOTES ON ARCHITECTURAL DRAWINGS 4. LOWERCASE LETTER ADJACENT TO LIGHTING FIXTURE INDICATES SWITCHING SCHEME. IF LIGHTING FIXTURE IS NOT TAGGED WITH A LOWERCASE LETTER, THE CIRCUIT SHALL BE ROUTED VIA LIGHTING CONTACTORS. REFER TO 2/E012 FOR ADDITIONAL INFORMATION. 5 ALL EQUIPMENT TO BE U.L. LISTED OR EQUIVALENT. 6. ALL LOW VOLTAGE WIRING MUST BE RUN IN CONDUIT CONCEALED IN WALLS. PLENUM RATED WIRING MAY BE RUN CONCEALED ABOVE CEILING WHEN ALLOWED BY THE LOCAL AHJ. 7 ALL EXPOSED CONDUIT MUST BE RUN STRAIGHT AND PARALLEL/PERPENDICULAR TO STRUCTURE. RUN CONDUIT ADJACENT TO EXISTING STRUCTURE OR ROOF DECK WHERE POSSIBLE. 8 REVIEW ANY QUESTIONS REGARDING INSTALLATION WITH OWNER PROJECT MANAGER. ELECTRICAL LIGHTING PLAN KEYNOTES:( 1 MASTER LIGHTING SWITCHBANK. REFER TO DETAIL 3 SHEET E012 FOR MORE INFORMATION. 2. PROVIDE VACANCY SENSOR, WATTSTOPPER MODEL #CS-50, MOUNTED AT 42" AFF. VERIFY EXACT LOCATION IN FIELD PRIOR TO ROUGH -IN. COORDINATE WITH ALL FINISH & TRIM DESIGN WITH ARCHITECT. VACANCY SENSOR TO BE SET FOR A 10 MIN. OFF DELAY. 3. WEATHERPROOF JUNCTION BOX & REQUIRED DISCONNECT .SWITCH FOR ILLUMINATED SIGN. COORDINATE EXACT LOCATION & POWER REQUIREMENTS WITH SIGN INSTALLER PRIOR TO ROUGH —IN. EMERGENCY LIGHTS AND EXIT SIGNS SHALL BE PROVIDED WITH 90 MINUTE BATTERY PACK AND SHALL BE CONNECTED TO THE NEAREST NORMAL LIGHTING CIRCUIT SERVING THE AREA AHEAD OF ANY LOCAL SWITCHING. 5. NIGHT LIGHTS SHALL BE PROVIDED WITH A CONTINUOUS OR CONSTANT HOT LINE AND SHALL BE WIRED AHEAD OF ANY LOCAL SWITCH, 6. LIGHTING CONTROL TIMESWITCHES AND CONTACTORS. REFER TO DETAIL 2 SHEET E012 FOR MORE INFORMATION. 7. GENERAL LIGHTING TIMED OVERRIDE SWITCH. REFER TO DETAIL 2 ON SHEET E012 FOR MORE INFORMATION. 8. NORMAL AND EMERGENCY LIGHTING OUTSIDE THE TENANT SPACE IS THE RESPONSIBILITY OF THE LANDLORD. 9. PROVIDE FIXTURE WITH EMERGENCY BATTERY BALLAST, CAPABLE OF 1350 LUMENS TOTAL OUTPUT FOR A MINIMUM OF 90 MINUTES. 10. COMBINATION EXHAUST FAN/LIGHT FIXTURE. PROVIDE MOTOR —RATED TOGGLE DISCONNECT SWITCH FOR EXHAUST FAN. CONNECT FAN TO VACANCY SENSOR. 11. PROVIDE ROOM CONTROLLER WATTSTOPPER MODEL #LMRC-101, OCCUPANCY SENSOR WATTSTOPPER MODEL #LMDC-100 AND DIGITAL WALL .SWITCH MODEL #LMSW 101 FOR CONTROL OF LIGHTING WITHIN STOCK ROOM. PROVIDE ALL NECESSARY LOW VOLTAGE WIRING PER MANUFACTURER REQUIREMENTS FOR A COMPLETE AND OPERATIONAL SYSTEM. LIGHTS TO BE PROGRAMMED TO BE MANUAL BY DIGITAL SWITCH AND AUTOMATICALLY OFF WITH 10 MINS OF NO OCCUPANCY BY OCCUPANCY SENSOR. 12. PROVIDE MULTI —WAY VACANCY SENSOR, WATTSTOPPER MODEL#CH-250, MOUNTED AT 42" AFF. CONTRACTOR TO INSTALL MULTI —WAY VACANCY SENSOR PER MANUFACTURER REQUIREMENTS. VERIFY EXACT LOCATION IN FIELD PRIOR TO ROUGH —IN. COORDINATE ALL FINISH & TRIM DESIGN WITH ARCHITECT. VACANCY SENSOR TO BE SET FOR A 10 MIN. OFF DELAY. EL REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC MAY 232014 City of Tukwila BUILDING DIVISION • RECEIVED CITY OF TUKWILA MAY 1:4 2014 PERMIT CENTER MEP Engineer of Record Randall A. Nelson, P. E. 14817 West 95th Street Lenexa, Kansas 66215 Phone 913 322 5150 r z 0 0 EC- W 0 M DATE rl z �yti ov 4e. ,o &)" f',(R°,r- "c4:, A AN wA..1 , x , , I --, ) 'ci 1'j.. 43448 i, EXPIRES 9/21/2015 ELECTRICAL LIGHTING PLAN LULULEMO\ ATHLETICA CO\STUCTIO\ STAN3ADS 21 SOUTHCENTER, SUITE 748 TUKWILA, WA 98188 ISSUE FOR SD 03/24/14 ISSUE FOR DD—LLL 04/15/14 ISSUE FOR DD—LLD 04/18/14 ISSUE FOR CD—LLL 05/01/14 ISSUE FOR CD —LLD 05/01/14 ISSUE FOR PERMIT xx/xx/xx ISSUE FOR BID xx/xx/xx Scale` AS INDICATED Date: 3/7/14 Drawn By: DP/DB Checked By. CF Job Number: 14 2.0115 Drawing: LIGHTING FIXTURE SCHEDULE OWNER PROCUREMENT QTY INSTALL NAME & SYMBOL FIXTURE LAMP HT. AFF INSTALL DIRECTIONS/ NOTES OWNER PROCUREMENT QTY INSTALL NAME & SYMBOL FIXTURE LAMP HT. AFF INSTALL DIRECTIONS/ NOTES ER pRQOIyIRFMENT QTY INSTALL NAME & SYMBOL FIXTURE LAMP HT. AFF INSTALL DIRECTIONS/ NOTES LED-F 7 SURFACE MTD FITTING ROOM PARTITION LED-F ITE HITE LINEAR AION WH FIXTUREHI-XWS28-PS), W/24V DIMMING, LED DRIVER (300-D3-400) - LED 3 WATTS/FT 24V 8'-0 3/4" CD TOP OF FIT ROOM PANEL FIXTURE TO BE MOUNTED ON FITTING ROOM PANEL W/ AION A TRACK MOUNTING SYSTEM FL 2 RECESSED FL 0 NU TONE F DELUXEFA DELUXE FAN LIGHT COMBO 2x18W CFL WITH GU24 BASE (INCLUDED) 8'-0" FAN LIGHT COMBO TO BE CENTERED IN ROOM 70 CFM EX1 3 SURFACE MOUNTED OR SUSPENDED EX1 BEST ELXTEU1RCW-EM EDGE LIGHT EXIT SIGN W/ BATTERY BACK-UP 5W FOR BATTERY BACKUP (EM) - EXIT SIGNS TO BE RED AND CLEAR PLEXI SPECIFIED, USED ONLY ON SALES FLOOR HB 10 SUSPENDED HB ��1 �� CON -TECH CGL125430KMVD2CMW HTF-CP LED HIGH. BAY 38 WATT LED (INCLUDED) 12'_6" LED -FM 7 FITTING ROOM PARTITION LED -FM AION LED LINEAR LIGHTING FIXTURE (WHITE) (8024- XW28-PS) W/ 24V DIMMING, LED DRIVEER(300-D3-24) LED 6.1 WATTS/FT 24V 8'-0 3/4" 0 TOP OF FIT ROOM PANEL FIXTURE TO BE MOUNTED ON FITTING ROOM PANEL (MIRROR SIDE ONLY) W/ AION A TRACK MOUNTING SYSTEM '':;\ EX2 2 SURFACE MOUNTED OR SUSPENDED EX2 BEST EZXTEU2RW-EM BEST EXIT SIGN W/ BATTERY BACK-UP 3.2W RED 3.8W GREEN - RA3 2 RECESSED RA3 CON -TECH RAN150038X3B 21LBL AMPM TI P T 3 L UL S O 3x 21 WATT PAR 3E LED R 4 K L 38 0 30 1250 / - FIXTURES TO BE SUPPLIED WITH TRIM. SET HEAD OWNERS DIRECTIONX ,, \ . .\• , . :,., `,\.. SUMP ENCED. D�:�'��'z" •;�;`; ;;�:. \., , ; TBD ,, :. , : :\\: :`: ; ;" •;, : ; „:-.::;:., .,\ <• \ , . ,\.\ ., ,.W/ ,•\, `. \..,, , \\„ \ „\, "` \.\\ \ ``: , \�\. " \ �':\,., \, ,..... .�,`` '`\ \, `,. \, SURFACE EX3 CLG. ��1DEDAMP DUAL LITE 2X 1W LED - 13' 0" MAX. LISTING AS:� [•Z.I�7 M N OU TED, RED PERLOCAL SUSPENDED WALL\, SDICTION :7RQ:UVII \, ,' \„ �•\. �,' S RE.�E DER , \ Ri'�: \:,� , �� •�, `CO ,TES N H�,'. \,� ,\ \` 1x 6a1:;1�3f�Ki :=1 p2, .\. \. \', \ �'` \. i'IN" •::�Ei.. G`:;`:: .� �' �.. \,, .\ ;\ .> \„ \ \.., '\` `�. „` \. D4 WALL AK OUTDOOR BREAK VI -BREAK- I M B - OUTDOOR WALL LIGHT. FINISH: CONCRETE 1 0 LED EXTERIORSCONE •\ . \\ ,:` \, \. `'�` \'. ,;,:. `\. y D \DAM � Cif \ +�� \ ,\ ,\ . REi�U R 'F� 'i�;t \` U 5b CT N 18 RECESSED RF3N TECH CO E\`�\ RA4LNC-230K-12D1 T4 —P CS 322E L .. 6 RECESSED LED ix 29W 230K12or27 LED , \+`\. USp�ND � � � �:� \ � \ �' \. t\ `\. :\\\\\-\ \, \\ .\ \ ;;\,_.\\, '; \.\ •\ \,, k;;ION-RbJ C,T ;;':,;' :'\\"",\\,,`,'. ,;' ;: :� � • , . ` , \: •, ;" \\`. ;I * D5 1 SURFACE D5 o O TOLOMENO WALL SCONE — — — —W ITEM ART TOL 7 10 MODEL: TOL1180 12.5 IN D/FIBERRF4 FLUORESCENT X24 —2 (1)18 W G Q COMPACT FLURESCENT _ 10 9" WATER FEATURE SURFACE MOUNTED IN W E E .` :\',. , \ ., , . \ , \...,., \�\` .,.. ..,, .,. \ ;: \. ,.,...,.....,,,. EX� ,,: , :\,�L�v��.;..,..ENCO,E: •\ „\�, � \ ,,..\ . �\.\\ , ,\�..HFAb >'�`;�:.' '` . �� ','``..:�' '; \� �=.::: j`�` �.'`,,�.A�=..., ; . \ ' ,' . ;:: "` ,.,, \,,. , ,:. A" ., O, �E;D..M',: LIsTING:;S \, \\\.\, \ \ \\ \ \,\, \\\ ',,` \.,\ \, \ � \\. \. • \\ :,, \� ,, : \ .\.. \\., \�, `:: :�� \ Igo N:TED\,, U. ,\\` \ S, E.. \,\, \ \ :�. , .\•.+„+ \ \ \`\ :\. \ ,, .\ .\ \, , ,, �,. ` ,� ,�,,,\ ,�:\\,.. :;�' '\:� 6EL0'::6VOa 2 •` 1�VA': ;T _ T, ,\ . \ •,. \ �\ �\ \ \ \ \ �` \ .,,.:\`\ \�\\\U\:\\ \ ` ,�\\\ \, \,=�,\�\.\\;, \ �. , \ `\\,,'. .:\ �.\, \:,,, `�`:\\•\\\\\\,,,'..::\ \; �, \`,�:�c:, \` \`,`. \ ,,'`ill ,\`„\\.,\. `\:�. .�,. •: `�\.,, ,,, '•' • iL�� p�OJ� •T ;;;,;:`,. \`\;+•\\•,:::,�c;`:;; ;?. RF4 6 RECESSED CREE CR6-800E—GU24 RC6 LED DOWNLIGHT 1 W 0 2 80 LUMENS CREE TRUEWHITE LED CEILING CE L G HT. STAFF ROOM RECESSED IN GWB CEILING D6 1 WALL MOUNTED LIGHTS UP RS-4038BN—MLF 1X EL/MDT 2 23W PHILIPS 23W CFL BOF ® 6'-6" 1 AT EACH TOILET ROOM MOUNTED ABOVE THE MIRROR SEE AND CENTERED.12or27 RF3EM 1 RECESSED RF3EM • CON —TECH RA4LNC-2-30K— H EBL B24 CST4322L-PL\ L 1x 29W 230K12or27 LED �'_6" 6" LED DOWN LIGHT WITH 90 MIN. EMERGENCY BATTERY BACK—UP, D6 r:-*-1 , :., , +\ .,,, ,, ' ,., "` ; \ .,j;: ` ; \\ ' ,\, '' ;;`..�\ �\, ,, , \'\ '., \\ .: \ :. \` :'SURFACE':" MQUN'fED: \;: ', $py• ,,; \ ` :`. \. .` �;�. \' \ ,\ �� H E ,,11V �L S ,,,\ .,\ \. ' ,.. ,;, �tNDS 62?�,T5H �, \\� FXA XEB� � UV�, WH> : 6C�, ,.z'�\\,`\?�:'';;`..,\��;\\'t ::\', ,\:`:-;' �� :, L to . , �, ,1N -,. , .`, ` ,,,�\\ T��Hb� ; ; ' \ 1 �5 8a' Nb \.\ „\�.\,'\;�:�.\\,::,�',,.,`;<��<\\,`.\:`\\':, ',\`:\`,: ,;,' ..VAR i= S. , � \.," \. „\. ;, ,:::,,`, \ �; :,; ,�\ . F IXTUR� T �•SU FACE�� M�U TE I �„ � ,R Q h D,.N: „`• \,.., t` : `'"' :' C�lLINGS; '�0 1` T �9 11 :AFF . \`: Q c\,•;.,. \, ,,`. , ,\` `:; .�';: �\':,U':;;:\�`:�\,:�;�::���:`::;��\����,.\,•�'; * D7 2 SUSPENDED D7 QUILL VINTAGE PLATINUM N LIGHT LED SUSPENSION L MODEL: 13500 D FINISH: 82-VINTAGE PLATINUMIMMARI 5 X4.8 W 120 V O LED MODULES 1600 LUMENS. >7 F SEE: ELEVATIONS CASH & FITTIN ROOM PENDENT G � \ �' \ \ \\�,. REC SSECi E :,' : ,, c,\ \ \ S aR H :W l M \ \ E ILL A S` ND=3 6��4�' H FXA � E 4' 2 B N.V � . `'::• � A P d L t� 2 W T H' 5 0, F1' T H ALTO RI V R A \ \ . ,�': :;,,, •'` F13tTUR�'TO . R T B EC GS MOUNT iN E E OU �D C l \ ,: \` ��;,,,,.,, .,\ ,•, .\.;'.��;.,. \ ;� �?`,� T D B :; �•;,.�.� \ �`"\ `; �, ;: \ ,.,, \ \ ;::. , \`\\+:;,\� \ \ \\ \ �:;: ,�. ' \•. `���: �'.\ `.;;' :,�: , ; \` ::` �USF' ND �$. E E �: \`:,;�: `, '; \ ;, �D > ` �:�' \` : \\ WI I ,U N H. _ WH ' AC �8 EB BD' T.', . / 4 :;, , UON :\•� tii ='2 LA . ilV:` .\, 0 \ .\ ?';z; ',' \ ':F12 T5 $30 H0 ': 4 .ALTO i ,O `.,.. ,\„ E O BE',�115 .E . DED; ERpi�t`�:• �iXfiUR \``' T P N CEILING STRUCTUR• IN E CEILIN,G• ,\,.• T \\ _..', A 1 ` , 0 AFF , , CL6 SUSPENDED CL6 o CON -TECH H CO E CL6230K12D1 L W 29 LED ., 2 6 �‘.�. ;; ` :� :\ :', , •..\\ :MOUNTED':; �,\ `„� ' � \ SURFACt:� ,;� �� � `: � 'T1 � „\\ ;. ,: \ ? CO. EGH,; ,\ 4 \,, ,\,. ;:' :: `:,, ;, L. 8 � l CUTTR �.: \ \ , , \ � AX\ , ,. „, ., TRA ;:Y `.,;'`\ CK OBE< MOUNTED;'TO GWB \,;\`. N CEILING:'' `:SEE `PLANS. Rik ,LENGT: S, , H hATtERNS &`F'IXT R U E QUANtI71ES,. '.\. ` .., F4 SURFACE MOUNTED 0,' NDED SUSPENDED F4; SIMKAR 1E232811UNV FLOURECENT STRIP WITH WIRE GUARDS 1 x32W T8 F32T8 TL830ALTO / PHILLIPS 12 0 STOCK ROOM CEILING MOUNTED , � �� \ \; �: SI MK R NT S TH TRIP ` .WIPNiwP WI QUA DS. E BATTER 1 �3 8�: ;, �1; \ G i HfiD. , ,\\. \. \. '\\� \:\ .�� NOTES: F8 2 SURFACE MOUNTED OR SUSPENDED F8 SIMKAR 1E2232B11UNV FLOURECENT STRIP WITH WIRE GUARDS GUARDS 2x 32W T8 F32T8/TL830ALT0 PHILLIPS 12 -0 STOCK ROOM CEILING MOUNTED T2 225' SUSPENDED T2 CON -TECH LB122-4P LB122-6P L6122-8P L6122-12P LUX BEAM 1 CIRCUIT TRACK 11'-9 MAX TRACK TO BE HUNG FROM STRUCTURE, VERIFY MOUNTING DETAILS W / DESIGNERS PRIOR TO INSTALLATION. SEE PLANS FOR LENGTHS, PATTERNS,& FIXTURE QUANTITIES 1. ALL FIXTURES ARE TO BE FURNISHED BY OWNER'S VENDOR, PLEASE CONTACT CS ILLUMINTATION FOR ALL LIGHTING PURCHASES & QUESTIONS. INSTALLED BY GC, UNLESS NOTED W ASTERIKS UNDER OWNER SUSIE HAMMER 760.477.1244 EXT.114 OR SHAMMEROCSILLUMINATION.COM / PROCUREMENT. 2. ALL FIXTURES ARE TO BE CONNECTED TO A LIGHTING CONTROL PANEL PROVIDED BY OWNER'S VENDOR, 3. CONTRACTORS SHALL CONFORM TO ALL APPLICABLE LOCAL, STATE CODES AND N.E.C. 4. ALL FIXTURES SHALL BE U.L. LISTED 5. ALL FIXTURES TO BE INSTALLED PER MANUFACTURER SPECIFICATIONS 6. ALL FLUORESCENT TO BE 3,000K 7. DO NOT SCALE DRAWINGS. FIELD VERIFY ALL DIMENSIONS. NOTIFY ARCHITECT OF VARIATIONS. F8 1 SURFACE MOUNTED OR SUSPENDED F8EM 1E2232IRE SIMKAR FLOURECENT STRIP WITH WIRE GUARDS & EM BATTERY BACKUP 2x 32W T8 F32T8/TL830ALT0 PHILLIPS 12'-0" STOCK ROOM HUNG FROM STRUCTURE TL1 127 TRACK MOUNTED TL1 SOLAIS XI24/40/30K/1600/WH/J 24W LED TRACK ® 11'-9" MAX FIXTURES TO BE MOUNTED ON TRACK, REFER TO PLANS FOR FIXTURE QUANTITY AND DIRECTION SET IN FIELD TL3 4 TRACK MOUNTED TL3 1 CON -TECH CTL804L-M - 3- P 10W LED TRACK 0 11'-9" MAX FIXTURES TO BE MOUNTED ON TRACK, OVER CASH WRAP REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC MAY 23 2014 City of Tukwila BIJILDIING DIVISION EL124 QLJ (0s RECEIVED CITY OF TUKWILA MAY 142014 14817 West 95th Street Lenexa, Kansas 66215 Phone 913 322 5150 0 p a w 0 sr 0 z EXPIRES 9/21/2015 SCHEDULE W X L 0 z Z .00 Et — woo zQ U 'S o— CVI— ISSUE FOR SD 03/24/14 ISSUE FOR DD-LLL 04/15/14 ISSUE FOR DO -LLD 04/18/14 ISSUE FOR CD-LLL 05/01/14 ISSUE FOR CD -LLD 05/01/14 ISSUE FOR PERMIT xx/xx/xx ISSUE FOR BID xx/xx/xx Scale: AS INDICATED Dote: 3/7/14 Drawn By: DP/DB Checked By: CF Job Number: 142.0115 Drawing: E120S.1 PERMIT CENTER ELECTRICAL LOW VOLTAGE PLAN SCALE: 1/4" = 1'-0" STOREFRONTOvA HEADCOUNT THERMAL SENSOR • FOR MUSIC DOWNLOADS 6 AHU_1 0 CM6 A C BBB FOR SECURITY J SPEAKER WIRING JUNCTION BOX REVIEWED , TH COIVIPLIAE NFPA 70 - NEC MAY 2 3 2014 City -Tukwila BUILDING DIVISION LOW VOLTAGE GENERAL NOTES: 1. ALL LOW VOLTAGE WIRING TO BE WHITE. 2. REFER TO SHEET A122 FOR SPEAKER LOCATION DIMENSIONS. 3. ALL CONDUIT WILL BE 3/4" AND ROUTED UP TO DECK UNLESS NOTED OTHERWISE. 4. ALL CONDUITS SHALL HAVE PULL STRING INSTALLED AND TIED AT EACH END. 5. ALL CONDUIT SHALL BE INSTALLED AND SECURED TO SUPPORT WEIGHT OF INTENDED SPEAKER. 6, SPEAKER WIRING JUNCTION BOX SHALL BE FULLY ACCESSIBLE. 7 ALL SPEAKER WIRE SHALL BE WITHIN CONDUIT BY CONTRACTOR AS REQUIRED BY CODE: 8 SPEAKER SYSTEM EQUIPMENT SHALL BE INSTALLED ON A LIGHT SHELF IN OFFICE. 9. COORDINATE EXACT LOCATION FOR SPEAKER SYSTEM EQUIPMENT. 10. SPEAKER ZONES: STOREFRONT AREA IS ZONE 1. HIGH CEILING AREA IS ZONE 2. BACK CEILING IS ZONE 3. 11. ALL COMPONENTS SHALL BE CONNECTED TO AN AC SURGE PROTECTOR STRIP. ELECTRICAL LOW VOLTAGE KEYNOTES:( 1 2 DAISY CHAIN SPEAKERS: ZONE 1-CASH WRAP, ZONE 2-SALES, ZONE 3-FITTING AREA, SUB -WOOFER. THESE CONDUITS RUN OUT TO THE STORE AND CONTAIN WIRES FROM THE OUTPUT SIDE OF THE VOLUME CONTROL AND THE SUBWOOFER (HOME RUN) CONNECTION TO THE AMPLIFIER. 2. SINGLE GANG JUNCTION BOX IN BACKWRAP FOR SUBWOOFER AMPLIFIER. PROVIDE CONDUIT FROM SPEAKER WIRING JUNCTION BOX TO DECK. CONDUIT CONTAINS (2) WIRES: (1) IS PIGTAILED TO 3VC INPUT WIRES, (1) IS THE HOME RUN FROM/TO THE SUBWOOFER. 3. SINGLE GANG JUNCTION BOX FOR VOLUME CONTROL FOR ZONE 1, ZONE 2, AND ZONE 3. DO NOT USE 3-GANG JUNCTION BOX. PROVIDE 3/4" CONDUIT FROM VOLUME CONTROL TO. DECK AS SHOWN IN DETAIL 5, SHEET 510S. EACH CONDUIT CONTAINS (2) WIRES: (1) FOR INPUT SIDE OF VOLUME CONTROL (FROM AMP), (1) FOR OUTPUT SIDE OF EACH VOLUME CONTROL (TO SPEAKERS). 4. NETWORK CABINET WITH 48 PORT PATCH PANEL. NETWORK CABINET TO HAVE A 6" CLEARANCE ON EACH SIDE AND IN FRONT OF BOX. SEE DETAIL 6, SHEET E510S FOR ILLUSTRATION. 5. PROVIDE ROUGH -IN CONSISTING OF 1" CONDUIT WITH PULL STRINGS AND JUNCTION BOXES FOR SECURITY DEVICES AT MAX. 42" A.F.F. CONDUIT TO BE CONCEALED IN WALL AND ROUTED UP TO DECK FOR FUTURE USE. SECURITY DEVICES AND WIRING BY OTHERS. FIELD VERIFY ACTUAL LOCATIONS. , , 6. PROVIDE JUNCTION BOX 54" AFF, PLASTER RING, AND 1/2" CONDUIT WITH PULL STRING ROUTED UP TO DECK. FINAL CONNECTION BY MECHANICAL CONTRACTOR. DEVICE LEGEND SYMBOL DESCRIPTION ✓ A ✓ B o C RJ45 CAT6 JACK RH12 JACK SMART JACK SPEAKER SYSTEM & SYMBOL LEGEND SYMBOL FIXTURE INSTALL DIRECTION/NOTES SPEAKER PENDANT STYLE CEILING SPEAKER. MOUNT HEIGHT TO MATCH HB FIXTURE HEIGHT. f SPEAKER FLUSH MOUNTED CEILING SPEAKER ® (iD SUB WOOFER SUB WOOFER MOUNTING HEIGHT 12" HIGHER THAN HB FIXTURE HT. OR FLUSH MOUNT AS REQ'D. SPEAKER SYSTEM EQUIPMENT - SSE DO CAMERA CAMERA ALIGN W/BOTTOM OF HB TRAFFIC COUNTER WALL/CEILING MOUNTED (16'-0" A.F.F. MAX) #VAP WIRELESS ACCESS POINT CEILING MOUNTED IN OFFICE AND SALES AREA. VERIFY EXACT LOCATION AND MOUNTING HEIGHT IN FIELD. 7. PROVIDE (5) 3/4" CONDUITS AND PULL STRINGS ROUTED IN OR UNDER SLAB AND ROUTED CONCEALED IN WALL UP TO DECK FOR FUTURE USE. REFER TO SHEET E11OS FOR ADDITIONAL POWER CONDUITS AT THIS AREA. COORDINATE WITH LANDLORD FOR SLAB TRENCHING REQUIREMENTS. 8. PROVIDE FIRE -RATED PLYWOOD TELEPHONE BACKBOARD. EXTEND ANY EXISTING CONDUIT TO THIS LOCATION FOR TELEPHONE SERVICE. COORDINATE WITH LANDLORD AND OWNER REPRESENTATIVE. REFER TO DETAIL 1, SHEET E510S FOR BACKBOARD SIZE AND ADDITIONAL INFORMATION. 9. PROVIDE JUNCTION BOX AND 1/2" CONDUIT ROUTED UP TO DECK FOR FUTURE USE FOR SECURITY CAMERAS. 12" 3/4" CONDUIT 4"x4" JUNCTION BOX WITH COVER MUSIC SOURCE 3/4" CONDUIT 4"x4" JUNCTION BOX WITH COVER TO INTERNET ROUTER OR WALL OUTLET ETHERNET CABLE EXTERNAL DC POWER SUPPLY SPEAKER AMPLIFIER16 GAUGE SPEAKER WIRE VSUBWOOFER FLUSH MOUNTED SPEAKER PENDANT MOUNTED SPEAKER 1 (SOUNDSCALE:NTS SYSTEM CONDUIT AND WIRING DETAILS ( RECEIVED CITY OF TUKWILA MAY 1;4 2094 PERMIT CENTER MEP Engineer of Record Randall A. Nelson, P. E. 14817 West 95th Street Lenexa, Kansas 66215 Phone 913 322- 5150 J t a 0 1/3 J DESCRIPTION a- DATE --1 z .0, ct". of �4, ,0 A A A. N. wAs41. 4l' �G� �o f� I„ 43448 44' 1 0.19 EXPIRES 9/21/2015►11T ELECTRICAL LOW VOLTAGE PLAN QLULULEMO\ ATHLETICA CO\STUCTIO\ STANDA3S 21 SOUTHCENTEF, SUITE 748 TUKWILA, WA 98188 ISSUE FOR SD 03/24/14 ISSUE FOR DD—LLL 04/15/14 ISSUE FOR DD—LLD 04/18/14 ISSUE FOR CD—LLL 05/01/14 ISSUE FOR CD —LLD 05/01/14 ISSUE FOR PERMIT xx/xx/xx ISSUE FOR BID xx/xx/xx Scale: AS INDICATED Date: 3/7/1 4 Drawn By: DP/DB Checked By. CF Job Number: 142.0115 Drawing: EXAMPLE GC TO PROVIDE 2X2 ACCESS PANEL FOR INSTALLATION AND SERVICE OF EAS EQUIPMENT. 3/4" CONCEALED CONDUIT FOR LOW VOLTAGE WIRING. MAXIMUM CABLE DISTANCE OF 35' FROM BOTTOM OF EACH ANTENNA TO AMS-9040 CONTROLLER. ANTENNA(TYP) BOTTOM OF MULLION/WALL MOUNTED ANTENNAS APPROX. 6" ABOVE FINISHED FLOOR. CONCEALED CONDUIT OR PULLSTRING FROM CAPACITOR BOARD ENCLOSURE TO FLOOR TRENCH. DIRECT BURIAL RATED ANTENNA COILS ROUTED INSIDE FLOOR TRENCH UNDER FINISHED FLOOR MATERIAL DIGITAL DOORMAX 4 ANTENNAS ONLY. DRAWING MAY NOT REFLECT ACTUAL STOREFRONT. AMS 9040 CONTROLLER REMOTE ALARM INSTALLATION NOTES: 1. EAS COMPONENTS SHOWN ABOVE DOOR DEPENDING ON STORE CONFIGURATION. COMPONENTS MIGHT BE LOCATED AT CONCEALED LOCATION UNDER MANNEQUIN PLATFORM OR BEHIND CASHWRAP AREA. MAXIMUM 35' CABLE DISTANCE SHOWN STILL APPLIES. SEE A-210 FOR REFERENCE. SYSTEM NOTES: 1. PROVIDE (2)DIGITAL DOOR -MAX 4 ANTENNAS, AMS-9040 CONTROLLER, AND ANTENNA MOUNTING KITS. 2. DISTANCE BETWEEN INSIDE SURFACES OF ANTENNAS MUST BE 4-6FT. 3. IF LOW VOLTAGE WIRING CONDUITS CANNOT BE CONCEALED, THE WIRING MAY BE ROUTED TO ANTENNAS FROM CONTROLLER USING 1/2" SURFACE MOUNTED CONDUIT. ROUTE SURFACE MOUNTED CONDUIT TO TOP OF MOUNTING CHANNEL. 4. • VERIFY EXACT REQUIREMENTS WITH MANUFACTURER PRIOR TO BID. 5. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS WITH MANUFACTURER PRIOR TO CONSTRUCTION. CONNECT TO MOUNTING CHANNEL REAR KNOCKOUT (TYP) AMS 3030 FLOOR ANTENNA EXAMPLE ONLY. DRAWING MAY NOT REFLECT ACTUAL STOREFRONT. CAPACITOR BOARD ENCLOSURE AMS 9040 CONTROLLER REMOTE ALARM GC TO PROVIDE 2X2 ACCESS PANEL FOR INSTALLATION AND SERVICE OF EAS EQUIPMENT. MAXIMUM DISTANCE 20' FROM CLOSE OF FURTHEST LOOP COIL TO CAPACITOR BOARD ENCLOSURE. 5/8" WIDE X 3/4" DEEP TRENCH CUT. REFER TO FLOOR TRENCHING TEMPLATE FOR LAYOUT. TRENCH WILL CONTNUE BEYOND TEMPLATE TO EXIT ROUTE OF ANTENNA COIL. AMS4030 FLOOR CUT DIMENSIONS floure U . Floor cut tllili6nsloius for sitlt(i{i antsnna system with oap Vox on left sfci; (Detection past edge) Fcrr, weir r" FloorAnlenna Cap Box (close to cols) Trench to cap box Trench cut In slob -4- Width: 1cm (518In) Depth: 3.8cm (1.51n) or 1.3 (.51n) 8cm (3jn Use handsaw to cut angles In comers. 91cm (361n) Floor Coil 1 Exit ti 15cm (5.5in) 169cm (66.51n) (361n) Floor Coll 2 IK:lure 1G. Floor cuts for sin gl+2 antenna system with cop box on ri ltl 7 irle TRENCH CUT SPECS SCALE: NTS 91cm (361n) Dimension cm in Width of ells 91 36 Depth of cells 91 36 Overlap of:oils 14 5.5 Width or anten"o 169 66.5 Detection Fast edge 15 6 Legs of angle cut 8 3 1.;i r L. c AMS-3030 INSTALLAION NOTES: 1. EAS COMPONENTS INSTALLED INSIDE OVERHEAD SOFFIT AREA 2. G.C. TO PROVIDE 2X2 ACCESS PANEL 3. G.C. TO PROVIDE 120VAC DEDICATED CIRCUIT DUPLEX AT 9040 CONTROLLER LOCATION. 4. G.C. TO PROVIDE SAWCUT PER AMS-3030 SPECS. 5. G.C. TO PROVIDE 3/4" CONDUIT/ PULL STRINGS STUGGED INTO SOFFIT AREA FOR CONCEALED EAS CABLES. 6. TYCO TO PORVIDE ALL EAS COMPONENTS AND FLOOR TEMPLATE AMS-3030 SAW CUT SPECS (CAN BE REVERSED AS NEEDED) PT- 0-------III-- Lfri ) ZE9040 CONTROLLER 17"X20"X6" 1. DOOR MAX EAS TO BE INSTALLED AT 3FT ENTRY. GC TO PROVIDE A CONDUIT FROM THE BOTTOM OF THE DOOR AND STUBBED OVER TO INSIDE THE CLOSET WHERE ZE9040 CONTROLLER WILL BE INSTALLED.. 2. GC TO PROVIDE 120VAC DUPLEX INSIDE THE CLOSET U.S. DECK 16' - 8" 3/4" CONDUIT SEE DOOR MAX NOTE CAPACITOR BOARD ENCLOSURE 15" X 18.7" X 3.3" 1 SOFFIT 11' - 6" REVIE WEDFOR CONCH NFPAMPLIA7O C. EN ECWIT MAY 2 3 2014 I City of Tukwila BUILDING DIVISION F.F.E 0" I •\ I (r ,l 1 ` ) � /\ I 111 I i iI i \II i 1�j I I n l I. i I li l I !1�, lit l 1 / I, 1(1 II -- I_ L---1 - i i1 it i -I 1- G.C. TO PROVIDE 2X2 ACCESS PANEL FOR INSTALATION AND SERVICE OF EAS EQUIPMENT 1•.) 1 I C.1 . 1 s1 REFER TO AMS-3030 SAW CUT SPECS FOR LAYOUT. TRENCH WILL CONTINUE BEYOND TEMPLATE TO EXIT ROUTE OF ANTENNA COIIL. �1 MAXIMUM CABLE DISTANC1E 20' FROM CLOSE OF LOP? TO CAPACITOR BOARD 1.-1 ENCLOSURE 011 I?f! I U S DECK 16' - 8" SOFFIT 11' - 6" F. F. E RECEIVED CITY OF TUKWILA 14817 West 95th Street co U) co (1) co (0 N J Phone 913 322 5150 DESCRIPTION Q 8 -i d z EXPIRES 9/21/2015 J L.L_I n V / Q LJ Q U I- U LLJ LL! ISSUE FOR SD 03/24/14 ISSUE FOR DD-LLL 04/15/14 ISSUE FOR DD-LLD 04/18/14 ISSUE FOR CD-LLL 05/01/14 ISSUE FOR CD -LLD 05/01/14 ISSUE FOR PERMIT xx/xx/xx ISSUE FOR BID xx/xx/xx Scale: AS INDICATED Date: 3/7/14 Drawn By: DP/DB Checked By: CF Job Number: 142.0115 Drawing: SENSORMATIC SYSTEM ISOMETRIC SCALE: NTS 3�SENSORMATIC SYSTEM PLAN AND ELEVATION SCALE: NTS MAY 14 2014 PERMIT CENTER 130.1 Device Placement Top to Bottom: 11-12 (2t1) Patch Panel 10 0.u) Empty 9 (iu) Cisco 2960 Switch 8 {JU) Cmpty 7 OW AT&T Netgate / USRobotics Modern 5.6 (2u) Cisco 2921. 'touter 4 (ni) Cisco 2901 Router 3 UU) Deli PowerEdge Server (not installed by REI) 2 ou) Empty 1(tu) CypberPowerUPS/PL)U NOTE: ENSURE THE CABINET IS LOCKED ONCE LV INSTALLATION IS COMPLETE, AND KEYS ARE GIVEN TO THE GC. KEYS ARE ONLY TO BE PROVIDED FOR THE CAMERA INSTALLATION, AND THEN HANDED OVER AT TURNOVER TO THE STORE MANAGER FOR STORAGE IN THE SMALL SAFE AT THE CASH DESK. NETWORK CABINET ILLUSTRATION SCALE: NTS (ILLUSTRATION FOR REFERENCE ONLY) Cisco 29(30 Catalyst Switch AT&T N:IS810 8200 iR, Cisco 2921 Router £ir,:7flA.it(:Anh- NX nms >J, WM /V1+wi - rcvntRa All ion of exit ,r.! (n) • w.wxr.rwMN..w .N.rrAN.u.r.i 101WWaINOMMIM. rtw�wr,w�..rrr. M�1iliMit 1OU Mr �=r.rr�r.r++rr.ra�..rrrt�rrrrrr �ru.rr1.WW1., rrM.Mw�1M�MMWMM 1`1 1MrAMM.1M M1.N1M1MN1M-+NNM.MNew.w.wlMOVI.rrMlMM•10111►. MNNr11MMMMM 111.0 rrr.l.a.rlrrrrrlrrrM.rrrla+r rarrrrMlrarr rNMrMrrar Y1s�I.r, ll�.I.�rrr-�/�i� Y7•��NMMlllls sll�r+-r�i/� rrM.M.WOM11 YMf-MMMIMINWOMIONWIM.MM11 fM1WWMY16111,111k, M-rMrlrrwWw104,14iitiM/ h . ,i 1m? r 0.1 u Cisco 2901 Router Wi in, hi du tohn1�n'1 us ,arno' 1,.•nl , PROVIDE JUNCTION BOX, SIZED AS NECESSARY SPEAKER CONDUIT TO BE ROUTED TO DECK. PROVIDE 12"x12" ACCESS PANEL IN CEILING, CENTERED ABOVE BACKWRAP SECTION. ALL THE CONTROLS AND THEN ONE (1) WITH J-BOX AT 90 TIE SPEAKER RUNS CONTROLS CONDUIT ARE PIGTAILED 3/4" CONDUIT DEGREES TO AND VOLUME TOGETHER. RJ45 FOR MUSIC DOWNLOADS. ALL DEVICES CENTERED WITHIN SHELVING MUSIC SYSTEM BY VENDOR ROUTE CONDUIT TO UP TO DECK FOR FUTURE USE. EAS DE-MAGNITIZER 1 7 OUTLET BEHIND WOOD PANEL DOUBLE DUPLEX IG FOR MUSIC. SEE PLAN FOR CIRCUITING. C5BACKWRAP/AUDIO/SECURITY 'SCALE: NTS SECURITY PINPAD DETAIL FOR ELECTRICAL CONNECTION INFORMATION ONLY. SEE ARCHITECTURAL DRAWINGS FOR BACK WRAP ORIENTATION. ALL CONDU CONCEALED TO BACK 0 NETWORK C NETWORK C MOUNTED C ABOVE OFF REFER TO ARCHITECTL DRAWINGS DETAIL 6, SHEET, FOF INFORMATIO ISOLATED G DUPLEX OU 6" ABOVE BACKSPLASI PLAN FOR CIRCUITING. ISOLATED G DOUBLE DU OUTLET AT SEE PLAN 1 CIRCUITING. (5) SPACE OUTLET (A, F). PROVID CONCEALED CONDUIT BETWEEN OUTLET BOXES AND NETWORK CABINET WITH PULL STRING. ITS IN WALL F ABINET ABINET N WALL ICE. IRAL \ND 'HIS MORE N. ROUND TLET AT ;OUNTER -I. SEE ROUND PLEX 15" AFF. =0R 8 RJ45 B, C, E, ®® 8 MANAGER'S DESK SCALE: NTS 3/4" CONDUIT ROUTED UP TO DECK FOR FUTURE USE. ISOLATED GROUND DUPLEX OUTLET MOUNTED WITHIN NETWORK CABINET. SEE PLAN FOR CIRCUITING. ISOLATED GROUND, USB OUTLET AT 6" ABOVE COUNTER BACKSPLASH. SEE SHEET E110S FOR MORE INFORMATION. (1) RJ45 OUTLET. COORDINATE ALL REQUIREMENTS IN FIELD. ISOLATED GROUND DUPLEX OUTLET AT 15" AFF. SEE PLAN FOR CIRCUITING. O CASHWRAP DETAIL SCALE: NTS NOTE: LOW VOLTAGE CONTRACTOR TO PROVIDE CABLES BEWTEEN CASH DESK, RJ45 JACKS, AND COIL IN EACH POS LOCATION AS PICTURED. OPEN SCALE: NTS NOTES: 1. G.C. SHALL PROVIDE ALL POWER AS REQUIRED FOR CASHWRAP. SEE CASHWRAP DWG AND ELECTRICAL DRAWINGS FOR POWER REQUIREMENTS. 2. ALL CONDUITS SHALL BE CONCEALED WITHIN THE WALLS WHERE POSSIBLE. 3. ALL TELEPHONE JACKS ARE BY OTHERS. 4. ALL CONDUITS SHALL HAVE CONTINUOUS PULLSTRINGS. 5. NO CONDUITS SHALL HAVE MORE THAN (3) 90 DEGREE SWEEPS WITHOUT A PULL BOX. 6. ALL PULL STRINGS ARE TO BE POLY. 7. G.C. TO SUPPLY CONVENIENCE OUTLETS PER CODE WITH PLASTIC PROTECTORS. 8. DEPENDING ON SERVICE AVAILABILITY SOME STORES WILL HAVE EITHER CABLE OR DSL INTERNET SERVICE. NOT BOTH. (2) 3/4" CONDUIT FOR SECURITY AND MAIN PHONE LINE ROUTED UP TO DECK FOR FUTURE USE. 4'-0" i MIN SEE NOTE B 3/41' CONDUIT ROUTED UP TO DECK FOR FUTURE USE. -PHONE CO. BLOCK FIRE ALARM CONTROL PANEL IF REQUIRED SECURITY MAIN CONTROL PANEL BACKBOARD LEGEND dWeLgill v BACKBOARD RECEPTACLE NETWORK JACK AT&T SMART JACK TELEPHONE BACKBOARD DETAIL NOTES: A. ALL WIRES SHALL BE STAPLED TO PANEL. ALL EXCESS WIRES SHALL BE COILED AND ZIP -TIED. B. 4" PVC PLAN TUBE WITH CAP. C. PROVIDE TELEPHONE BACKBOARD AS FIRE RATED PLYWOOD, SIZED AS INDICATED, MOUNTED TO WALL, PAINT TO MATCH ADJACENT WALL. D. INSTALL TELEPHONE BACKBOARD BY END OF WEEK 3 OF CONSTRUCTION. TELEPHONE BACKBOAD DETAIL SCALE: NTS REVIEWED FOR COMPLIANCE WITH NFPA 74 - NEC MAY 23 2014 City of Tukwila BUILDING DIVISION ELP4- 01165 . RECEIVED CITY OF TUKWILA 14817 West 95th Street Lenexa, Kansas 66215 Phone 913 322.5150 DESCRIPTION a d Z U) I-- LLJ n ( ) n rY U Q LLJ F k— / <C 0 0 LLJ n' _1 ( ran ) 0 —J U ISSUE FOR SD 03/24/14 ISSUE FOR DD—LLL 04/15/14 ISSUE FOR DD—LLD 04/18/14 ISSUE FOR CD—LLL 05/01/14 ISSUE FOR CD —LLD 05/01/14 ISSUE FOR PERMIT xx/xx/xx ISSUE FOR BID xx/xx/xx S0O1e: AS INDICATED Date: 3/7/14 Drawn By. DP/DB Checked By. CF Job Number: 1 42.011 5 Drawing: MAY 1 4 2014 PERMIT CENTER 51OS ELECTRICAL SPECIFICATIONS B GENERAL CONDITIONS: A. THE REQUIREMENTS AS SET FORTH UNDER GENERAL CONDITIONS INSTRUCTIONS TO BIDDERS AND GENERAL REQUIREMENTS ARE A PART OF THIS CONTRACT. B. BIDS SHALL BE BASED ON A COMPLETE/FULL SET OF DRAWINGS. C. CONTRACTOR MUST READ THE ENTIRE SPECIFICATIONS COVERING OTHER BRANCHES OF WORK AND IS RESPONSIBLE FOR COORDINATION OF THE WORK WITH WORK PERFORMED BY OTHER TRADES. SCOPE OF WORK: A. CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING. BIDS SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS. ALL REQUIREMENTS INCLUDING MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS ARE TO BE OBTAINED PRIOR TO AND INCLUDED IN BID PRICE. FIELD VERIFY ALL EXISTING ELECTRICAL AND TELEPHONE EQUIPMENT, LOCATIONS, CONDITIONS ETC. FAILURE TO VISIT THE SITE SHALL NOT RELIEVE THE CONTRACTOR FROM ANY RESPONSIBILITY IN THE PERFORMANCE OF THE ELECTRICAL WORK. B. FURNISH ALL LABOR, MATERIALS, TESTING, EQUIPMENT, INCIDENTALS AND TOOLS TO PERFORM ELECTRICAL WORK SHOWN, NOTED OR SCHEDULED FOR A COMPLETE AND FINISHED INSTALLATION. 1. MATERIALS, PRODUCTS AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW AND AS SUCH APPEAR ON THE UNDERWRITERS LABORATORIES LIST OF APPROVED ITEMS AND SHALL BE SIZED IN CONFORMITY WITH REQUIREMENTS OF THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND OTHER APPLICABLE CODES, WHICHEVER ARE MORE STRINGENT. C. THE WORK IS TO BE IN ACCORDANCE WITH THE LATEST EDITION OF THE NEC AND ALL APPLICABLE CODES. D. INCLUDE ANY LABOR AND MATERIALS NOT SPECIFICALLY MENTIONED, BUT NECESSARY TO PROVIDE A COMPLETE AND FULLY OPERATIVE ELECTRICAL SYSTEMS. PERMITS: A. SECURE AND PAY FOR ALL REQUIRED PERMITS, FEES, ASSESSMENTS AND INSPECTION CERTIFICATES THAT RELATE TO THE ELECTRICAL CONTRACT. B. FURNISH APPROVED CERTIFICATE OF FINAL INSPECTION, AND TURN OVER TO OWNER AT COMPLETION OF PROJECT. DRAWINGS AND SPECIFICATIONS: A. THESE ELECTRICAL PLANS ARE DIAGRAMMATIC, NOT SHOWING EVERY ITEM IN EXACT LOCATION OR DETAIL. MEASUREMENTS AND LOCATIONS MUST BE FIELD VERIFIED AND COORDINATED WITH ARCHITECTURAL, PLUMBING, HVAC, FIRE PROTECTION, FIRE ALARM, STRUCTURAL, AND OTHER BUILDING DRAWINGS. SHOP DRAWINGS: A. FOR SUBSTITUTIONS ONLY, SUBMIT FIVE COPIES OF MATERIAL LISTS AND SHOP DRAWINGS FOR MAJOR EQUIPMENT TO THE OWNER'S CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO ORDERING EQUIPMENT. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS EARLY ENOUGH IN PROJECT TO ALLOW AMPLE TIME FOR OWNER'S REVIEW WITHOUT CAUSING TIME DELAYS OR CONFLICTS IN THE JOB PROGRESS. SUBMITTALS SHALL BE IN ACCORDANCE WITH GENERAL CONDITIONS AND THE MANUFACTURERS LISTED ON THE DRAWINGS AND SHALL BEAR THE STAMP OF THE CONTRACTOR SHOWING THAT HE HAS REVIEWED AND APPROVED THEM AND THAT THEY ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS. LACK OF SUCH CONTRACTOR'S APPROVAL WILL BE CAUSE FOR REJECTION WITHOUT REVIEW BY THE OWNER. B. WHERE TRADE NAMES, BRANDS OF MANUFACTURERS OF EQUIPMENT MATERIALS ARE SHOWN ON THE DRAWINGS. OR SPECIFICATIONS THE • EXACT EQUIPMENT SHALL BE USED ON THE PROJECT. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL/REPLACEMENT AT THE REQUEST OF THE OWNER'S CONSTRUCTION MANAGER (AT THE ELECTRICAL CONTRACTORS EXPENSE). CONDUITS: A. CONDUIT SHALL BE STANDARD STEEL RIGID, IMC OR EMT (THIN WALL) ACCORDING TO LOCAL CODE AND LANDLORD REQUIREMENTS. CONDUIT SHALL BE CONCEALED IN FINISHED AREAS, EXCEPT AS OTHERWISE APPROVED BY ARCHITECT. USE RIGID CONDUIT IN ALL OPEN CEILING CONDITIONS. RUN CONDUIT IN STRAIGHT LINES (PARALLEL OR PERPENDICULAR) TO DEMISING WALLS ALONG EXISTING STRUCTURE OR DECK WHERE POSSIBLE. PAINT TO MATCH. EMT CONNECTIONS SHALL BE COMPRESSION OR SET SCREW TYPE. B. FLEXIBLE CONDUIT OR TYPE MC CABLE SHALL BE USED FOR FINAL CONNECTIONS TO LIGHT FIXTURES, MOTORS AND VIBRATING EQUIPMENT ONLY; AND WHERE SO USED TO BE GROUNDED WITH A SEPARATE FULL SIZED GREEN GROUNDING CONDUCTOR. FINAL TYPE MC/FLEX CONNECTIONS SHALL BE LIMITED TO 6'-0" IN LENGTH. (ARRANGE CIRCUITS SO AS TO AVOID THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILING AREAS, JUNCTION BOXES LOCATED ABOVE LAY —IN CEILINGS ARE ACCEPTABLE.) PAINT TO MATCH. 1. MINIMUM SIZES OF CONDUITS SHALL BE 3/4" FOR STANDARD CONDUIT, AND 1/2" FOR FLEX CONDUIT (1/2" STANDARD CONDUIT AND 3/8" BX CABLE MAY BE USED AS SPECIFIED ABOVE, IF ACCEPTABLE WITH LANDLORD AND LOCAL CODES, ELECTRICAL CONTRACTOR SHALL FIELD COORDINATE WITH LANDLORD & INSPECTION AGENCIES PRIOR TO INSTALLATION). ELECTRIC METALLIC TUBING (EMT) SHALL BE GALVANIZED OR ELECTRO-GALVANIZED. FITTINGS SHALL BE SET SCREW OR COMPRESSION TYPE, FITTING SHALL BE AS MANUFACTURED BY REGEL, STEEL CITY, RACO, T & B, EFCOR OR EQUAL. EMT SHALL BE USED FOR FEEDERS AND BRANCH CIRCUITS RUN ABOVE SUSPENDED CEILINGS OR CONCEALED IN INTERIOR PARTITIONS. 2. PAINTING OF ELECTRICAL CONDUITS, ETC., IF REQUIRED, WILL BE BY GENERAL CONTRACTOR. C. THE USE OF ROMEX, AC CABLE IS NOT PERMITTED UNLESS NOTED OTHERWISE AND APPROVED BY THE ENGINEER. D. MAXIMUM CONDUIT HANGER SPACING SHALL BE 8'-0" FOR 3/4" THRU 1/4" AND 10'-0" FOR 1-1/2" THRU 4" CONDUITS. DO NOT SUPPORT CONDUIT FROM THE CEILING SYSTEM. LEAVE A #10 AWG PULL WIRE OR NYLON PULL STRING IN ALL EMPTY CONDUITS. F. SECURE ALL RACEWAYS TO THE BUILDING STRUCTURE IN A RIGID AND SECURE MANNER, USING FASTENERS SUCH AS "CADDY CLIPS" OR EQUAL. G. FLASH AND COUNTERFLASH ALL RACEWAYS WHICH PENETRATE THE ROOF OR USE PITCH POCKETS. INSURE THAT PENETRATIONS ARE COMPLETELY WEATHERPROOF. ALL RACEWAY SYSTEMS EXPOSED TO THE WEATHER SHALL BE WEATHERPROOF. PRIOR APPROVAL BY LANDLORD IS REQUIRED TO ADD ADDITIONAL EQUIPMENT LOADS TO STRUCTURE OR TO MAKE HOLES IN EXISTING ROOF. NOTIFY LANDLORD'S ROOFING CONTRACTOR AT LEAST 72 HOURS PRIOR TO ANY REQUIRED ROOF WORK. H. REVIEW ANY QUESTION REGARDING INSTALLATION WITH TENANT CONSTRUCTION MANAGER. 1A_LBEI A. WIRE SHALL BE SINGLE CONDUCTOR COPPER WITH 600 VOLT INSULATION. MINIMUM WIRE SIZE SHALL BE #12 AWG, ALL WIRE AND CABLE SHALL BE NEW AND SHALL BE BROUGHT TO THE SITE IN UNBROKEN PACKAGES. ALL WIRING OF ANY TYPE SHALL BE IN CONDUIT. NO STRANDED WIRE ALLOWED FOR #10 AND #12 AWG. MINIMUM WIRE SIZE 20 AMP BRANCH CIRCUIT SHALL BE AWG LISTED SIZE PER DISTANCE SHOWN BELOW. DISTANCE SHALL BE MEASURED FROM THE PANELBOARD CIRCUIT BREAKER TO THE FARTHEST OUTLET. a. #12 LESS THAN 100 FEET b. #10 BETWEEN 100 — 150 FEET c. #8 BETWEEN 150 250 FEET d: #6 OVER 250 FEET GENERAL WIRING SHALL BE THW OR THHN. (ALUMINUM CONDUCTORS ARE NOT PERMITTED.) WIRE CONNECTORS SHALL BE EQUAL TO SCOTCHLOCK FOR #8 AND SMALLER, AND EQUAL TO T & B "LOCK—TITE" FOR #6 AND LARGER. C. THE USE OF SHARED NEUTRALS IS ACCEPTABLE FOR LIGHTING AND RECEPTACLE CIRCUITS OTHER THAN GFCI AND ISOLATED GROUND CIRCUITS IF INSTALLED IN ACCORDANCE WITH NEC. ALL WIRING TO BE COLOR CODED AS FOLLOWS: COLORS FOR 208/120V CONDUCTORS PHASE A: BLACK PHASE B: RED PHASE C: BLUE NEUTRAL: WHITE EQUIPMENT GROUND: GREEN ISOLATED GROUND: GREEN WITH YELLOW STRIPE COLORS FOR 480/277V CONDUCTORS PHASE A: BROWN PHASE B: ORANGE PHASE C: YELLOW NEUTRAL: WHITE EQUIPMENT GROUND: GREEN LIGHTING: A. INSTALL OWNER PROVIDE LIGHTING FIXTURES AND LAMPS. COORDINATE EXACT LOCATION AND ALL MOUNTING REQUIREMENTS WITH ARCHITECT, OWNER, AND MANUFACTURER PRIOR TO ROUGH —IN. LIGHT FIXTURES SHALL BE SUPPORTED FROM THE BUILDING STRUCTURAL WITH 12GA WIRE SUPPORT TO OPPOSING CORNERS OF EACH RECESSED LIGHTING FIXTURE IN SUSPENDED CEILINGS. INSTALLATION SHALL CONFORM TO THE PROVISIONS OF THE BUILDING CODE. WIRED GROUND SYSTEM: A. FURNISH AND INSTALL A COMPLETE WIRED GROUNDING SYSTEM FOR ELECTRICAL EQUIPMENT AND CIRCUITS AS SHOWN ON THE DRAWINGS AND DESCRIBED GENERALLY BELOW. ALL GROUNDING CONDUCTORS SHALL BE GREEN, WHERE EXPOSED IN PANEL, SWITCHBOARD, OUTLET, BOXES, ETC. C. ALL ENCLOSURES AND NON -CURRENT CARRYING METALS TO BE GROUNDED. CONDUIT SYSTEM TO BE ELECTRICALLY CONTINUOUS. ALL LOCK NUTS MUST CUT THROUGH ENAMELED OR PAINTED SURFACES ON ENCLOSURES. WHERE ENCLOSURES AND NON —CURRENT CARRYING METALS ARE ISOLATED FROM THE CONDUIT SYSTEM, USE BONDING JUMPERS WITH APPROVED CLAMPS. D. RUN A SEPARATE GROUNDING CONDUCTOR IN EACH CONDUIT, #12 MINIMUM, OR AS SHOWN ON DRAWINGS. FOR PANEL FEEDERS BOND THE GROUNDING CONDUCTOR TO THE CONDUIT, WHERE ENTERING AND LEAVING THE CONDUIT. ALL GROUND CLAMPS SHALL BE PENN—UNION OR EQUAL, SIMILAR TO "GPL" TYPE. CONDUIT GROUND BUSHINGS SHALL BE THOMAS & BETTS OR EQUAL, SIMILAR TO #3800 SERIES WITH NYLON INSULATED THROAT. ALL DEVICES SHALL BE BONDED TO THE CONDUIT SYSTEM. USE A BONDING JUMPER BETWEEN THE OUTLET BOX AND THE DEVICE GROUNDING TERMINAL. METAL -TO -METAL CONTACT BETWEEN THE DEVICE YOKE AND THE OUTLET BOX IS NOT ACCEPTABLE AS A BOND FOR EITHER SURFACE MOUNTED BOXES OR FLUSH TYPE BOXES. ALL JUNCTION BOXES, OUTLET BOXES AND PULL BOXES SHALL BE BONDED TO THE CONDUIT SYSTEM. ALL FLEXIBLE CONDUIT SHALL BE JUMPERED WITH A GROUND CONDUCTOR. WIRE DEVICES: A. COLOR OF WIRING DEVICES AND COVERPLATES SHALL BE SELECTED BY ARCHITECT. (SEE PLAN NOTES FOR ADDITIONAL INFORMATION), 1. RECEPTACLES SHALL BE 20 AMP, 3—WIRE GROUNDING TYPE EQUAL TO HUBBELL 5362. 2. SWITCHES SHALL BE 20 AMP SPECIFICATION GRADE, RATED AT 120 OR 347 VOLT, AS REQUIRED. 3. SPECIAL DEVICES SHALL BE A SPECIFICATION GRADE. 4. EQUAL BY ARROW -HART, GENERAL ELECTRIC, BRYANT, PASS & SEYMOUR, OR SIERRA. PANELBOARDS AND SAFETY SWITCHES: A. PROVIDE BRANCH CIRCUIT PANELS WHICH SHALL BE OF THE BOLTED CIRCUIT BREAKER TYPE WITH SOLID COPPER BUSSING FULL SIZED NEUTRAL,, 25% GROUND BUSSING, OVERALL HINGED/LOCKABLE DOOR, AND TYPEWRITTEN DIRECTORY INSIDE DOOR. ALL SERVICE ENTRANCE EQUIPMENT SHALL BEAR THE MANUFACTURER'S LABEL WHICH SHALL STATE THAT THE EQUIPMENT IS RATED FOR SERVICE ENTRANCE APPLICATION IN ACCORDANCE WITH N.E.C. LOAD BALANCE ALL ELECTRICAL PHASES AT PANELS AND SWITCHBOARDS. TWO AND THREE POLE BREAKERS SHALL BE COMMON TRIP TYPE. WHEN USED AS SWITCHES IN 120V. AND 277V. LIGHTING CIRCUITS, FURNISH TYPE "SWD" BREAKERS IN ACCORDANCE WITH N.E.C. SQUARE D OR EQUAL BY SIEMENS ITE, CUTLER HAMMER, OR GENERAL ELECTRIC (OR APPROVED EQUAL). B PROVIDE SAFETY AND DISCONNECT SWITCHES, FUSED OR NON —FUSED, AS CALLED FOR ON DRAWINGS AND AS REQUIRED BY CODE. (FUSES AS MANUFACTURED BY BUSSMAN, CHASE SHAWMUT, ECONOMY FUSE CO., OR LITTLE FUSE CO. ARE ACCEPTABLE). DISCONNECT SWITCHES THAT ARE INSTALLED AT AIR CONDITIONING EQUIPMENT, HEAT PUMPS, ETC SHALL BE FUSED IN ACCORDANCE WITH THE EQUIPMENT'S NAME PLATE REQUIREMENTS PER N.E.C. SWITCHES SHALL BE HEAVY DUTY, QUICK MAKE/QUICK BREAK TYPE, FUSIBLE OR NON —FUSIBLE, WEATHERPROOF AS INDICATED ON THE DRAWINGS, OR AS REQUIRED BY LOCAL CODES. LOAD AND HORSEPOWER RATED AS MANUFACTURED BY SQUARE D, SIEMENS ITE, CUTLER HAMMER, OR GENERAL ELECTRIC (OR APPROVED EQUAL). C. MANUAL MOTOR STARTERS WITH OVERLOAD PROTECTION MAY BE USED FOR FRACTIONAL HORSEPOWER MOTORS THAT DO NOT REQUIRE AUXILIARY CONTROL. SINGLE PHASE STARTERS SHALL BE SQUARE D OR EQUAL. THREE PHASE STARTERS SHALL BE PROVIDED WITH OVERLOAD DEVICE IN EACH PHASE MATCHED TO MOTOR NAMEPLATE RATING. MAGNETIC MOTOR STARTERS (MINIMUM SIZE #1) SHALL BE USED FOR ALL SINGLE PHASE AND THREE PHASE MOTORS RATED ABOVE 1/2 HP OR THAT REQUIRE AUXILIARY CONTROL. PROVIDE CONTROL DEVICES (CONTACTS, TRANSFORMERS, ETC.) IN STARTERS AS REQUIRED FOR INTERLOCKS, COORDINATE WITH MECHANICAL AND/OR TEMPERATURE CONTROL CONTRACTORS. COMBINATION STARTERS, WHEN USED, SHALL CONTAIN FUSIBLE SWITCHES. BOXES: A. OUTLET BOXES AND COVERS PRESSED STEEL KNOCKOUT. JUNCTION, PULL BOXES AND CODE GAUGE SIZE. SHALL BE GALVANIZED, ONE-PIECE COVERS SHALL BE GALVANIZED STEEL, C. INSTALL BOXES RIGIDLY ON BUILDING STRUCTURE AND SUPPORT INDEPENDENTLY OF THE CONDUIT SYSTEM. ALSO PROVIDE SUITABLE/PROPER BOX EXTENSIONS TO EXTEND BOXES TO FINISHED FACES OF WALLS ETC. ALL OUTLET BOXES TO HAVE SUITABLE BLOCKING BEHIND THEM TO MINIMIZE THE DEFLECTION THAT OCCURS WHEN PLUGGING/UNPLUGGING INTO THESE DEVICES. D. WHERE A 277 VOLT LIGHT SWITCH IS GANGED WITH A 120 VOLT RECEPTACLE PROVIDE A SUITABLE DIVIDER OR SEPARATE JUNCTION BOXES IN ACCORDANCE WITH N.E.C. AND LOCAL CODES. SERVICES: A. PROVIDE TEMPORARY SERVICE FROM LANDLORD'S DESIGNATED LOCATION AND PROVIDE LIGHTING, POWER AND WIRING AS REQUIRED TO FACILITATE APPLICABLE TEMPORARY NEEDS, AND FURNISH EXTENSION CORDS. ANY TEMPORARY WIRING, FUSES, ETC., SHALL BE REMOVED UPON . COMPLETION OF THE PROJECT. PROVIDE GROUND FAULT PROTECTION AS REQUIRED BY LOCAL CODES. PROVIDE ELECTRICAL SERVICE AS SHOWN ON THE DRAWINGS, FIELD VERIFY EXACT REQUIREMENTS PRIOR TO BIDS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR POWER COMPANY SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. CLOSELY COORDINATE ENTIRE INSTALLATION WITH LANDLORD AND POWER COMPANY AS REQUIRED. (PROVIDE EQUIPMENT THAT IS COMPATIBLE WITH AVAILABLE FAULT CURRENT LEVELS, PROVIDE "CABLE LIMITERS" IF NECESSARY FOR SYSTEM COORDINATION). FIELD VERIFY EXACT TYPE, SIZE, LOCATION, REQUIREMENTS, ETC. OF EXISTING POWER AND TELEPHONE FACILITIES PRIOR TO BIDDING PROJECT. C. MAKE PROVISIONS FOR NEW TELEPHONE SERVICE AS REQUIRED, AND AS INDICATED ON THE DRAWINGS. D. CONDUIT SYSTEM FOR TELEPHONE DISTRIBUTION WITHIN TENANT'S PREMISES SHALL BE PROVIDED AS REQUIRED FOR A COMPLETE TELEPHONE SYSTEM. OUTLET BOXES SHALL BE 4" SQUARE MINIMUM WITH SINGLE DEVICE COVER AND TELEPHONE PLATE. FIELD COORDINATE WITH OWNER'S CONSTRUCTION MANAGER TO AVOID CONFLICTS. STEP DOWN TRANSFORMER: A. PROVIDE DRY —TYPE TRANSFORMER AS MANUFACTURED BY SQUARE "D". HEAVY DUTY, ACME, GENERAL ELECTRIC, SIEMENS ITE OR OTHER EQUIVALENT MANUFACTURERS, OF THE ENCLOSED VENTILATED TYPE WITH KVA AND VOLTAGE RATINGS AS CALLED ON THE DRAWINGS WITH COILS DESIGNED FOR 150 DEGREE C RISE ABOVE A 40 DEGREE C AMBIENT WITH 100% OF RATED LOAD CONNECTED TO THE SECONDARY, CLASS 220 DEGREE C INSULATION AND A MINIMUM OF SIX STANDARD FULL CAPACITY TAPS (TWO ABOVE AND FOUR BELOW NORMAL). SOUND. LEVEL/DECIBELS SHALL BE IN ACCORDANCE WITH "NEMA" STANDARDS, AND INSTALLATION SHALL INCLUDE "KORFOUND" OR EQUAL VIBRATION —DAMPENING MOUNTS AND FLEXIBLE STEEL CONDUIT FOR PRIMARY AND SECONDARY CONNECTIONS TO MINIMIZE SOUND TRANSMISSION. MOUNT TRANSFORMER ON SEPARATE VIBRATION ISOLATORS. THESE ARE ADDITIONAL VIBRATION ISOLATORS AND ARE USED IN CONJUNCTION WITH ANY'' INTEGRAL FACTORY INSTALLED VIBRATION ISOLATORS. FIRE ALARM SYSTEM: PROVIDE THE FOLLOWING NEW EQUIPMENT, COMPATIBLE WITH, OR OF THE SAME MANUFACTURER AS, THE EXISTING FIRE ALARM CONTROL PANEL AND SYSTEM, AT LOCATIONS INDICATED ON THE DRAWINGS, AS REQUIRED BY BUILDING CODES, THE LANDLORD, OR ALL THREE, AND CONNECT TO THE EXISTING FIRE ALARM CONTROL PANEL: A. ADDITIONAL INITIATING DEVICES, INDICATING APPLIANCES, AND INTERCONNECTING CIRCUITS. B. ADDITIONAL ZONE MODULES REQUIRED BY NEW ZONING. C. NEW AMPLIFIERS AND OTHER EQUIPMENT THAT MAY BE REQUIRED TO INCORPORATE THE NEW INITIATING DEVICES AND INDICATING APPLIANCES INTO THE EXISTING SYSTEM. A NEW ZONE MAP, INCLUDING ALL EXISTING ZONES AND ALL NEW ZONES, FRAMED, MOUNTED UNDER GLASS, AND INSTALLED ADJACENT TO THE FIRE ALARM CONTROL PANEL. HORN/STROBES SHALL MEET ALL REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT. E. PROVIDE ALL REQUIRED PROGRAMMING. F. PROVIDE TESTING OF SYSTEM AS REQUIRED. G. PROVIDE SHOP DRAWINGS WITH EQUIPMENT CUTSHEETS, WIRING DIAGRAMS, POINT—TO—POINT FIRE ALARM CABLING PLAN, VOLTAGE CALCULATIONS, AND BATTERY CALCULATIONS FOR THE MAIN FIRE ALARM CONTROL PANEL. LIGHTING CONTACTORS AND TIMER SWITCHES: A. CONTACTORS FOR CONTROL OF LIGHTING AND SIGNS SHALL BE SQUARE "D", CLASS 8903, TYPE "L", ELECTRICALLY HELD. EQUIVALENT PRODUCTS BY OTHER MANUFACTURERS ARE PERMITTED. B. ELECTRONIC DIGITAL TIME SWITCHES SHALL BE USED FOR CONTROL OF SHOW WINDOW LIGHTING, SIGNS, AND IF REQUIRED/DESIRED OTHER LIGHTING. THE ELECTRONIC DIGITAL TIMER SHALL BE PROVIDED WITH A 7—DAY FORMAT, 365 DAY ADVANCED HOLIDAY SCHEDULE, CAPABLE OF DIFFERENT SETTINGS EACH DAY OF THE WEEK, AND HAVE AN ASTRONOMIC FEATURE. INSTALLATION: A. ALL ELECTRIC WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING AND REPAIRING. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS CHANNELS, RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK AND SHALL BE FASTENED TO BUILDING STEEL, CONCRETE OR MASONRY, BUT NOT PIPING OR DUCTWORK. ALL CONDUIT SHALL BE CONCEALED WHEREVER POSSIBLE. EXPOSED CONDUITS SHALL BE IN STRAIGHT LINES PARALLEL WITH OR AT RIGHT ANGLES TO COLUMN LINES OR BEAMS AND SEPARATED AT LEAST 3 INCHES FROM WATER LINES WHEREVER THEY RUN ALONGSIDE OR ACROSS SUCH LINES. ALL CONDUCTORS SHALL BE IN CONDUIT, DUCTS OR OTHER CODE APPROVED RACEWAYS. B. ALL LINE AND LOW VOLTAGE POWER AND CONTROL WIRING (EXCEPT HVAC, DATA, TELEPHONE AND VIDEO/TV LOW VOLTAGE WIRING) INCLUDING CONNECTIONS TO MOTORS, DAMPERS, INTERLOCKING, ETC., SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. ALL LINE VOLTAGE WIRING, CONDUIT, AND FINAL CONNECTIONS FROM THE POWER SOURCE THRU THE STARTER/DISCONNECT ETC. TO THE MOTOR OR EQUIPMENT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. ALL HVAC RELATED LOW VOLTAGE CONTROL WIRING, CONDUIT AND FINAL CONNECTIONS ARE THE RESPONSIBILITY OF THE MECHANICAL/TEMPERATURE CONTROL CONTRACTOR, UNLESS OTHERWISE NOTED ON THE PLANS. ALL DATA, TELEPHONE AND VIDEO/TV LOW VOLTAGE WIRING AND CONNECTIONS ARE THE RESPONSIBILITY OF THE OWNER'S VENDORS: C. THE ELECTRICAL CONTRACTOR SHALL DO ALL CUTTING, CHASING OR CHANNELING AND PATCHING REQUIRED FOR ANY WORK UNDER THE ELECTRICAL DIVISION, ANY CUTTING SHALL HAVE PRIOR APPROVAL OF THE LANDLORD. SLEEVES SHALL EXTEND AT LEAST TWO (2") INCHES ABOVE FINISHED FLOOR AND ALL SLEEVES, OPENINGS, ETC., THROUGH FIRE RATED WALLS AND FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RTV" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL BY HILTI AFTER CONDUIT/CABLES INSTALLATION SO AS TO RETAIN THE FIRE RATING. D. THE ELECTRICAL CONTRACTORS, INSOFAR AS THE WORK IS CONCERNED, SHALL AT ALL TIMES KEEP THE PREMISES IN A NEAT AND ORDERLY CONDITION AND, AT THE COMPLETION OF THE WORK, SHALL PROPERLY CLEAN UP AND CART AWAY ANY DEBRIS AND EXCESS MATERIAL. E. THE FOLLOWING EQUIPMENT SHALL BE IDENTIFIED WITH ENGRAVED BAKELITE NAMEPLATES AS TO NAME AND/OR FUNCTION: DISTRIBUTION PANELS, LIGHTING PANELS, MOTOR STARTERS AND DISCONNECT SWITCHES. NAMEPLATES TO BE APPROXIMATELY 1" X 2" IN SIZE AND BE FASTENED WITH POP RIVETS OR SCREWS. F. THE LOCATION OF OUTLETS AND EQUIPMENT SHOWN ON THE DRAWINGS ARE APPROXIMATE AND THE ARCHITECT/OWNER'S CONSTRUCTION MANAGER SHALL HAVE THE RIGHT TO RELOCATE ANY OUTLETS OR FIXTURES BEFORE THEY ARE INSTALLED WITHOUT ADDITIONAL COST. IN THE EVENT OF AND CONFLICTS WITH EXISTING OR NEW FIXTURE LAYOUT GENERAL CONTRACTOR TO CONTACT LULULEMON PROJECT MANAGER. G. ELECTRICAL CONTRACTOR SHALL RECORD ALL FIELD CHANGES IN THE WORK AS THE JOB PROGRESSES, AND TURN THIS "AS BUILT" INFORMATION OVER TO THE OWNER AT THE COMPLETION OF THE PROJECT. ELECTRICAL CONTRACTOR SHALL PROTECT ALL FIXTURES/EQUIPMENT AGAINST DAMAGE FROM LEAKS, ABUSE, ETC., AND PAY COST OF REPAIR OR REPLACEMENT OF FIXTURES OR EQUIPMENT MADE NECESSARY BY FAILURE TO PROVIDE SUITABLE SAFEGUARDS OR. PROTECTION. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERATING SYSTEM. AFTER ALL EQUIPMENT HAS BEEN INSPECTED AND APPROVED, THOROUGHLY CLEAN ALL EQUIPMENT PROVIDED UNDER THIS WORK JUST PRIOR TO COMPLETION OF PROJECT. J. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ANY/ALL NECESSARY. ELECTRICAL DEMOLITION WORK THAT IS REQUIRED TO FACILITATE THE NEW INSTALLATION, FIELD COORDINATE PRIOR TO BIDS. REMOVE AND/OR MODIFY EQUIPMENT, ETC. AS REQUIRED FOR A COMPLETE INSTALLATION. ANY EQUIPMENT OR DEVICE REMAINING IN USE AFTER PART OF THE EQUIPMENT OR DEVICES HAVE BEEN REMOVED ARE TO BE RECONNECTED TO EXISTING OR NEW CIRCUITS AND LEFT IN WORKING ORDER. FEEDERS TO PANELS AND WIRING TO OTHER EQUIPMENT TO BE ROUTED CONCEALED IN FINISHED AREAS. COORDINATE ANY DISRUPTION OF ELECTRICAL OR TELEPHONE SERVICES WITH LANDLORD AND OWNER'S CONSTRUCTION MANAGER TO AVOID CONFLICTS. GUARANTEE: A. MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE. DEFECTS WHICH APPEAR DURING THAT PERIOD SHALL BE CORRECTED AT THE ELECTRICAL CONTRACTOR'S EXPENSE. B. FOR THE SAME PERIOD, ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK OR EQUIPMENT FURNISHED AND/OR INSTALLED BY THE ELECTRICAL CONTRACTOR. FINALLY: A. IT IS THE INTENT THAT THE FOREGOING WORK SHALL BE COMPLETE IN EVERY RESPECT AND THAT ANY MATERIAL OR WORK NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS, BUT NECESSARY TO FULLY COMPLETE THE WORK SHALL BE FURNISHED. B. PROVIDE AND INSTALL TYPED PANEL SCHEDULES FOR ALL PANEL BOARDS. PROVIDE AND INSTALL BLACK PLASTIC, WHITE ENGRAVED NAMEPLATES ON EXTERIOR OF ALL PANELBOARDS. PROVIDE ONE COMPLETE SET OF STAMPED PLANS TO BE CONTAINED IN A PVC TUBE MOUNTED ON PHONE BOARD. REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC MAY 23 2014 City of Tukwila I BUILDING DIVISION EL1M 0�Co5' RECEIVED CITY OF TUKWILA MAY 1-.42014 PERMIT CENTER MEP Engineer of Record Randall A. Nelson, P. E. 14817 West 95th Street Lenexa, Kansas 66215 Phone 913 322 5150 J 1. 1 U DESCRIPTION g DATE ,ad z ie9QogwA A. P&'1 " d0 4, &i443448 4. 411 ' \.` yy 9 , rri EXPIRES 9/21/2015 ELECTRICAL SPECIFICATIONS LULULEMON ATHLETICA CO\STRUCTIO\ STA\DADS 21 SOV iHCEN 1ER, SUITE 748 TUKWILA, WA 98188 ISSUE FOR SD 03/24/14 ISSUE FOR DD—LLL 04/15/14 ISSUE FOR DD—LLD 04/18/14 ISSUE FOR CD—LLL 05/01/14 ISSUE FOR CD —LLD 05/01/14 ISSUE FOR PERMIT xx/xx/xx ISSUE FOR BID xx/xx/xx Scale` AS INDICATED Dat8: 3/7/1 4 Drawn By: DP/DB Checked By. CF Job Number: 142.0115 Drawing: