Loading...
HomeMy WebLinkAboutPermit EL14-0577 - BUY BUY BABY - TENANT IMPROVEMENTBTJY BTJY BABY 17687 SOUTHCENTER PKWY EL1 4-0577 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT 3523049005 17686 SOUTHCENTER PKWY Project Name: BUY BUY BABY Permit Number: EL14-0577 Issue Date: 11/4/2014 Permit Expires On: 5/3/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: KIR TUKWILA 050 LLC/KIMCO 3333 NEW HYDE PARK STE 100 PROPERTY TAX DEPARTMENT, NEW HYDE PARK, OH, 11042 KEVIN MOUSTY 7100 E PLEASANT VALLEY RD , CLEVELAND, OH, 44131 STERLING ELECTRICAL CONTRS 5907 196TH ST SW #101, LYNNWOOD, WA, 98037 STERLEC910JL Expiration Date: Phone: (216) 520-1551 Phone: (425) 774-1903 DESCRIPTION OF WORK: TENANT INTERIOR RENOVATION OF EXISTING RETAIL SPACE. PROVIDING ALL NEW LIGHTING, RECEPTACLES AND LOW VOLTAGE WIRING THROUGHOUT SPACE. Valuation of single family: $0.00 Valuation of mf/comm: $306,000.00 Type of Work: TENANT IMP Fees Collected: $5,303.48 Electrical Service Provided by: PUGET SOUND ENERGY Water District: HIGHLINE,TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2014 2012 Permit Center Authorized Signature: Date: hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development pert and agthe conditions attached to this permit. Signature: Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. E L i m--O5 7 7 Project No. . Date Application Accepted: (ot-J Date Application Expires: l -s1 E (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: King Co Assessor's Tax No.: 17686 South Center Parkway, Tukwila, WA, 9818 Suite Number: Floor: 1 Tenant Name: buy buy Baby PROPERTY OWNER Name: Matt Barker, Kimco Realty Address: 3535 Factoria Blvd., Suite 520 City: Bellevue State: WA Zip: 98006 CONTACT PERSON person receiving all project communication Name: Mark Kuhn, MCG Architecture Address: 7100 E. Pleasant Valley RD , Suite 320 City: Cleveland State: oh Zip: 44131 Phone: (216) 520-1551 Fax: (216) 520-1567 Email: New Tenant: Yes ❑ ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 306,000 Scope of Work (please provide detailed information): Tenant interior renovation of existing retail space. Providing all new lighting, receptacles and low voltage wiring throughout space Will service be altered? IJ Yes ❑ No Adding more than 50 amps? El Yes ❑ No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel ® Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm • :: ❑ Telecommunication ❑ Temporary Service Property Served by: 2 Puget Sound Energy ❑ Seattle City Light H.\Applications\Forma-Applications On Line \2013 Applications \Electrical Permit Application Revised 7-I-13.docx Revised: July2013 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $65.00 ❑ Temporary service (generator) $80.90 ❑ Manufactured/mobile home service $86.25 (excluding garage or outbuilding) ❑ Carnivals $80.60 Number of concessions $10.80 ea Each ride and generator truck $10.80 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL -CONTRACTOR: Signature: f�`��..—� Date: 06/13/2014 Print Name: Mark Kuhn, MCG Architecture Day Telephone: (216) 520-1551 Mailing Address: 7100 ETleasant Valley RD , Suite 320 Cleveland', OH 44131 City H:\Applications\Fortin-Applications On Line\2013 Applications\Electrical Permit Application Revised 7-1-13.docx Revised: July 2013 bh State Zip Page 2 of 2 Cash Register Receipt City of Tukwila Receipt Number R3005 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID 6,64149 D14-0191 Address: 17686 SOUTHCENTER PKWY pn: 3523049005 ,363.4 DEVELOPMENT $8,917.75 PERMIT FEE R000.322.100.00.00 0.00 $8,913.25 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $445.66 TECHNOLOGY FEE R000.322.900.04.00 0.00 $445.66 EL14-0577 Address: 17686 SOUTHCENTER PKWY Apn: 3523049005 4.283 ELECTRICAL $4,079.60 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $4,079.60 TECHNOLOGY FEE $203.98 TECHNOLOGY FEE R000.322.900.04.00 0.00 $203.98 M14-0127 . Address: 17686 SOUTHCENTER PKWY Apn: 3523049005 MECHANICAL $2,388.70 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $2,356.20 TECHNOLOGY FEE $119.44 TECHNOLOGY FEE R000.322.900.04.00 0.00 $119.44 PG14-0103 Address: 17686 SOUTHCENTER PKWY Apn: 3523049005 $486.36 GAS $125.50 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $93.00 PLUMBING $337.70 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $305.20 TECHNOLOGY FEE $23.16 TECHNOLOGY FEE R000.322.900.04.00 0.00 $23.16 TOTAL FEES PAID BY RECEIPT: R3005 $16,641.49 Date Paid: Thursday, September 04, 2014 Paid By: BUY BUY BABY Pay Method: CHECK 8023003 Printed: Thursday, September 04, 2014 1:42 PM 1 of 1 CWSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT PermitTRAK QUANTITY PAID $7,526.50 D14-0191 Address: 17686 SOUTHCENTER PKWY Apn: 3523049005 $5,793.61 DEVELOPMENT $5,793.61 PLAN CHECK FEE R000.345.830.00.00 0.00 $5,793.61 EL14-0577 Address: 17686 SOUTHCENTER PKWY Apn: 3523049005 $1,019.90 ELECTRICAL $1,019.90 PLAN CHECK FEE R000.345.832.00.00 0.00 $1,019.90 M14-0127 Address: 17686 SOUTHCENTER PKWY Apn: 3523049005 $597.18 MECHANICAL $597.18 PLAN CHECK FEE R000.322.102.00.00 0.00 $597.18 PG14-0103 Address: 17686 SOUTHCENTER PKWY Apn: 3523049005 $115.81 GAS $31.38 PLAN CHECK FEE R000.322.103.00.00 0.00 $31.38 PLUMBING $84.43 PLAN CHECK FEE R000.322.103.00.00 TOTAL FEES PAID BY RECEIPT: R2412 0.00 $84.43 $7,526.50 Date Paid: Thursday, June 19, 2014 Paid By: MCG ARCHITECTURE Pay Method: CHECK 2810 Printed: Thursday, June 19, 2014 11:37 AM 1 of 1 SYSTEMS INSPECTION NO. INSPECTION*RECORD Retain a copy with permit cM577 PERMIT NO. ' CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431,3670 Permit Inspection Request Line (206) 438-9350 Project: gi 6 i 1 Ul -Type of Inspection: Afit--- >s,: claressi idri 6- Cl'l - Date Called: Special Instructions: —Date Wanted: Requester: / Phone No: aiApproved per applicable codes. Dcorrections required prior to approval. :COMMENTS 1 inspector 1C1')J4C REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Btvd., Suite 100. Call to schedule reinspection. -Date: 024 If 311( 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Permit Inspection Request Line (206) 438-9350 INSPECTION NO. INSPECTION RECORD Retain a copy with permit th P RMIT NO. ' CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 Project: & a . 6.- _ ipulD431 Type of Inspection: , AIAI.-- 'Address: j7610 .5--. Pl• Date Called: Special Instructions: Date Wanted: 0 c Requester: --riztros Phone No: 2s3 31( wotpi E3Approved per applicable codes. Corrections required prior to approval. COMMENTS: (,* - 5riff Inspector: Jrrig&JAIK Date: A vefu3in REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. thifOlc77 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 INSPECTION -RECORD Retain a copy with permit Project g g iii tfiff3k61 Type of Inspection: (44 tfd Address" I ' I .i /70/05(. pt. Date Called: Special Instructions: Date Wanted: 0 ca,rtio 'F.Trt. Requester: Phone No: g Approved per applicable codes. 0 Corrections required prior to approval. i. COMMENTS: - (fru-ski coltq — _Z06.4 /Al ay-Oue-nr Inspector: ...all,/ Date: Azioq REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTIOITRECORD Retain a copy with permit INSPE • ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 ttlitorp Project: 8) 4?$. ' Type of Inspection: tiCt, Address: I . /Ma (5-c- PY- Date Called: _ Special In tructions: Date Wanted: /...--- P.m Requester: Phone No: OApproved per applicable codes. Corrections required prior to approval. COMMENTS: Mc pm/6A rc-belyczs 44k) yrr1fk5 611-4-141)(4,1 I Aci\P3t41 Inspector: Date: ollorhr REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 577 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 INSPECTION RECORD Retain a copy with permit Project 7 & gv 1, it. f,37 Type of Inspection: , Ai 'Address.. i /6pgr :3.: t. v• Date Called: thkit>K6Ad 114, Special Instructions: Date Wanted: / a.m. Requester: Phone No: i EJApproved per applicable codes. Corrections required prior to approval. -COMMENTS: i")(< - AuJAw5 pJAg Ar (*let EJR,A-e Inspector: 40:715640tek ittr Date: 1 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit 64-03-71 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 436-9350 Project: fou & 1 1 4 Type of Inspection: c,iced 4At Address: 17144) .( jel ...J.11.0.• f - Date Called: / 1 Special Instructions: Date Wanted: / 4a.m.., I . . Requester: Phone No: :Approved per applicable codes. Corrections required prior to approval. COMMENTS: ni - ()Pm., 63Vei\ Pi-koro Aor LAIA14 Inspector: Date: 411 III LI REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Cali to schedule reinspection. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431-2451 INSPECTION RECORD64-45'77 Retain a copy with permit INSPECTION N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 Project: 606(4k Type of Inspection`/ Ybk4440 Date Called: U ,,-� Address: 1��ol+ �S C- P Special Instructions: Date Wanted: I ( L. Claw" p.m. Requester: Phone No: DApproved per applicable codes. Corrections required prior to approval. COMMENTS: 1),7 1 I/ AFL - (5)&A/ 1IT-S. Inspector: Date: ( (i REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Info Compliance forms do not require a password to use. Instructional and calculating cells are write- Project Address buybuyBaby Parkway Super Center Date 6/3/2014 17574 South Center Parkway For Building Department Use +- Come Tukwila, Washington 98188 Applicant Name: MCG Architecture Applicant Address: 250 Sutter St., Suite 500, San Francisco, CA 94108PIO Applicant Phone: 415-974-6002 Project Description ❑ New Building ❑ Addition Alteration v Plans Included Lighting Compliance Path ® Lighting Power Density Calculations 0 Total Building Performance (If Total Building Performance then only LGT-CHK is required.) r Lighting Power Allowance Method Selection required to enable LPA forms 0 Building Area Met ace 'EVIEVI�ED Fp COMPLIANCE 1Af1� 6 -S y ..r4P ,,� , E. if- p ace Me od"'� ,VW.4S3.� u' ,,..% / °'G'Nt „ fi, Interior Lighting System Description Briefly describe lighting system type and features. All new lightindi and r ta,o �'�� WIECi JUL 10 2014 -` i .-'y i } f, ), 1717 [ ? d s r ''�. . y City of Tukwila Additions and Change of Space Use (C1 T ' `'8Ag.ri1! li N =..: ..__ Addition area or Change of Space Use area complies with all applicable provisions as stand alone project is combined with existing building lighting systems to demonstrate compliance with all applicable C101.4.3 Area Method (LTG-INT-8LD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum proposed (including existing if applicable) lighting wattage of Addition or Change of Use space. Provide applicable lighting C405.2 and commissioning of lighting controls per C405.13. ❑ Addition area provisions per Provide Building allowed and controls per Alterations, Renovations and Repairs (C101.4.3.1) J 60% or more of luminaires in space replaced Area Method (LTG-INT-BLD) or Space -By -Space Method (LTG-INT-SPACE) Compliance Form. Document maximum within the lighting retrofit space in Maximum Allowed Wattage table and proposed (including existing) lighting wattage in table. Retrofit and non -retrofit spaces shall be documented separately using multiple forms. Provide Building allowed wattage Proposed Wattage ❑ Less than 60% of luminaires in space replaced Provide a separate Space -By -Space Method (LTG-INT-SPACE) Compliance Form for this retrofit area. Document existing total wattage within the lighting retrofit space in cell provided in the Maximum Allowed Wattage table. Document proposed (including existing) lighting wattage in the Proposed Wattage table. ❑ Lamp and/or ballast replacement within existing luminaires only — existing total interior building wattage not increased ❑ New wiring installed to serve added fixtures and/or fixtures relocated to new circuit Provide applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific application controls (C405.2.3), and commissioning of lighting controls per C405.13 ❑ New or moved lighting panel Provide all applicable fighting controls as noted for New Wiring, automatic time switch controls (C405.2.2.1), and commissioning of lighting controls per C405.13. ❑ Space is reconfigured - luminaires unchanged or moved only Provide all applicable lighting controls as noted for New tiring and commissioning of lighting controls per C405.13. • No changes are being made to the interior lighting and space use not changed. RECEIVED ELLLI- 0577 IUKWILA JUN 19 2014 PERMIT CENTER ��•' uli in' rea Vk nod` -INT-E 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Project Address buybuyBaby Parkway Super Center Date 6 /3 /2 014 Lighting Alterations, Renovations & Building Additions 0 Less than 60% * 60% or more 0 Stand alone 0 Addition Notes: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing bldg lighting to demonstrate compliance. Refer to C101.4.3. b. For retrofits and building additions, provide Building Area types and gross interior areas in the Maximum Allowed Lighting table. If a builidng addition will comply as combined with the overall existing builidng, include all applicable existing Building Area types and gross interior areas. c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. d. If less than 60% of existing fixtures will be replaced, use LTG-INT-SPACE form. For Building Department Use Maximum Allowed Lighting Wattage Building Area* Location (plan #, room #, or ALL) Area Description Allowed Watts per ft2 Gross Interior Area in ft2 Watts Allowed . (watts/ft2 x area) Retail ALL buybuy Baby Retail Store 1e33 25995 34573 * Select Table C405.5.2(1) Building Area from drop down menu. Total 25995 Proposed Lighting Wattage Building Area* Location (plan #, room #) Fixture Description** Number of Fixtures Watts/ Fixture Watts Proposed Retail E2.3 B8 15 48 720 Retail E2.3 BR-4 5 145 725 Retail E2.3 B4 6 25 150 Retail E2.3 A16 129 145 18705 Retail E2.3 Al2 9 113 1017 Retail E2.3 A8 40 77 3080 Retail E2.3 DS/DM 9 93 837 Retail E2.3 D1 4 48 192 Retail E2.3 D 1 48 48 Retail E2.3 E 3 3 9 Retail E2.3 J 3 19 57 Retail E2.3 A4 23 38 874 Retail E2.3 C74 4 14 56 Retail E2.3 C73 4 26 104 Retail E2.3 C72 3 42 126 Retail E2.3 LFTRACK 34 50 1700 Retail E2.3 G 26 19 494 Retail E2.3 G1 13 24 312 Retail E2.3 G2 59 24 1416 * Select Table C405.5.2(1) Building Area from drop down menu. ** include existing to remain lighting and exempt lighting equipment per notes below. Compliance by Building Area Building Area Warnings Total Allowed Watts Total Proposed Watts Interior Lighting Power Allowance Retail 34573 30622 COMPLIES Total Notes: 1. Proposed Wattage for each Building Area type shall not exceed the Allowed Wattage for that Building Area type. Trading wattage between 34573 30622 Building Area types is not allowed u the Building Area Method compliance path. 2. Proposed fixtures must be listed in .iilding area in which they occur. Include ALL propo: _ _ lighting fixtures. 3. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 4. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 5. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank. 6. Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures. Identify as existing in fixture description. `Li hti>r Motor ;an' . 'ransfor � er r t , , n, a a, Y t :. } �.,:., ... g g, .., �? ; Per►aa�tDocu tsCheCki�st LT:r:„I! _ 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Address buybuyBaby Parkway Super Center Date 6/3/2014 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes LIGHTING CONTROLS (Section C4O5 2) C405.2.1.1 Manual interior Indicate on plans the manual control type & locations served; E2.3 C405.2.1.2 lighting controls Indicate of plans the 50% lighting load reduction method provided or identify exception taken Automatic time Indicate lighting system automatic shut-off capability - identify lighting zone areas served on plans; C405.2.2.1 switch controls and override switching Indicate locations of override switches on plans and the areas served, include area sq. ft.; Indicate locations where automatic shutoff is provided by other methods (occupancy sensor, daylight controls, etc) C405.2.2.2 Occupancy sensors Indicate on plans the locations served by occupancy sensors E2.3 C405.2.2.3 Daylight zones - Vertical fenestration Indicate vertical fenestration primary and secondary daylight zone areas on plans, include sq. ft.; and skylights Indicate skylight daylight zone areas on plans, include sq. ft. C405.2.2.3.2 Daylight zone Indicate on plans the locations served by daylight zone controls; controls Indicate in plans the lighting load reduction (dimming) method - stepped or continuous dimming C405.2.3 Specific application lighting controls - General Indicate on plans the locations served by specific application lighting controls C405.2.3 - Display and accent Indicate lighting control method for display and accent lighting, and display case lighting; E4.3 Items 1&2 lighting Indicate these fixtures are controlled independently from both general area lighting and other lighting applications within the same space C405.2.3 - Item 3 Hotel/motel guest rooms Provide a lighting control device at each guest room entry for all permanently installed fixtures in guest room; Indicated whether lighting control is manual or automatic C405.2.3 - Item 4 Supplemental task lighting Provide automatic shut-off vacancy controls for supplemental task lighting, including under -shelf or under -cabinet lighting C405.2.3 - Lighting for non - Identify eligible non -visual applications and method of lighting control; Item 5 visual applications Indicate these fixtures are controlled independently from both general area lighting and other I ighting applications within the same space C405.2.3- Lighting equipment Indicate lighting control method for lighting equipment for sale or demonstration; Item 6 for sale or demonstration Indicate these fixtures are controlled independently from both general area lighting and other lighting applications within the same space C405.2.3 - Item 7 Means of egress lighting If egress lighting power density is greater than O.05W /ft2, indicate method of automatic shut-off during unoccupied periods; Identify on plans the egress fixtures that function as both normal and emergency means of egress illumination C405.10 C405.11 Cooler and freezer lighting Provide vacancy device or timer to turn off fixtures within 15 minutes of unoccupancy for cooler and freezer lighting fixtures with lamp efficacy less than 40 lumens per watt C405.2.4 Exterior lighting controls Indicate on exterior lighting plans the automatic lighting control method and locations served C405.6.1 Exterior building grounds lighting controls Provide motion sensor controls for building grounds fixtures rated at greater than 100 w atts with lamp efficacy less than 60 lumens, or identify exception taken Identify applicable commissioning documentation requirements per Section C408 or el igibility for exception; C408.3 Lighting system functional testing Provide written procedures for functional testing of all automatic controls and describe the expected system response; Identify in construction documents the party responsible for functional testing of automatic lighting controls INTERIOR LIGHTING POWER & EFFICACY (Sections C4O5.5, C4O5.10, C405.11) !a 19ap ► o or °anrt, .ans ormeri er►nit'Doceck1ist 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Jan 2014 Project Address buybuyBaby Parkway Super Center Date 6/3/2014 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes C405.5.1 Provide fixture schedule with fixture types, lamps, ballasts, and rated watts per fixture; E1.1 C405.5.1.1 C405.5.1.2 Total connected Identify spaces eligible for lighting P g 9 9 power exemption on plans and in compliance forms; C405.5.1.3 C405.5.1.4 interior lighting power Identify lighting equipment eligible for exemption in fixture schedule and in compliance forms; Indicate that exempt lighting equipment is in addition to general area lighting and is controlled independently C405.4 Exit signs Provide exit sign types and rated watts per fixture in fixture schedule (maximum 5 watts per fixture) C405.10 C405.11 Cooler and freezer lighting For lighting in walk-in coolers and freezers, and refrigerated warehouse coolers and freezers, provide rated lamp efficacy (in lumens per watt) in fixture schedule L Lighting Power Calculation - Indicate compliance path taken C405.5.2 Building Area Method Complete required compliance forms — proposed wattage per building area does not exceed maximum allowed wattage per building area. Identify locations of building areas on plans E2.3 C405.5.2 Space -By -Space Method Complete required compliance forms — total proposed wattage does not exceed maximum allowed wattage. Identify locations of space types on plans, including retail display areas as applicable EXTERIOR LIGHTING POWER & EFFICACY (Section C405.6) Total connected Provide fixture schedule with fixture types, lamps, ballasts, and rated watts per fixture; C405.6.2 exterior lighting power Identify exterior applications eligible for lighting power exemption on plans and in compliance forms; Indicate that exem pt exterior lighting is controlled independentl y from non-exempt exterior lighting Table C405.6.21 () Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ C405.6.1 Exterior building grounds lighting For building grounds fixtures rated at greater than 100 w atts, provide rated lamp efficacy (in lumens per watt) in fixture schedule C405.6.2 Exterior lighting power calculations Complete required compliance form — proposed wattage for exterior lighting plus base site allowed does not exceed maximum allowed MOTORS & TRANSFORMERS (Sections C405.8, C405.9) C405.8 Electric Motors For motors not part of an HVAC system, provide electric motor schedule on electrical plans with hp, rpm, and rated efficiency C405.9 Transformers Provide distribution transformer schedule on electrical plans with transformer size and efficiency ion, provide explanation: ELM I-oS�� Jennifer Marshall From: Mousty, Kevin <KMousty@mcgarchitecture.com> Sent: Wednesday, July 09, 2014 1:05 PM To: Jennifer Marshall Cc: DeCapite, Marie Subject: RE: correction letter #1 for M14-0127 Hi Jennifer — Per our conversation earlier today — Mark is no longer with MCG. Can you please forward any comments / updates to myself and Marie DeCapite Kmousty@mcgarchitecture.com Mdecapite@mcgarchitecture.com Thanks! Kevin Kevin Mousty Principal /Associate MCG Architecture 7100 East Pleasant Valley Road, Suite 320 Cleveland, OH 44131 (T) 216.520.1551 (F) 216.520.1567 http://www.mcgarchitecture.com Follow us on Linkedln From: Jennifer Marshall [mailto:Jennifer.MarshalIPTukwilaWA.gov] Sent: Wednesday, July 09, 2014 4:03 PM To: Mousty, Kevin Subject: correction letter #1 for M14-0127 Attached is the correction letter per our telephone conversation. I have also attached the Revision Submittal Form referenced in the letter. Jennifer Marshall Permit Technician, City of Tukwila T: 206 431-3670, F: 206 431-3665 The City of opportunity, the community of choice. 1 City of Tukwila Department of Community Development November 3, 2014 KEVIN MOUSTY 7100 E PLEASANT VALLEY RD CLEVELAND, OH 44131 RE: Application No. EL14-0577 BUY BUY BABY 17686 SOUTHCENTER PKWY Dear KEVIN MOUSTY: Jim Haggerton, Mayor Jack Pace, Director Permit application EL14-0577 for the work proposed at BUY BUY BABY (17686 SOUTHCENTER PKWY) has not been issued by the City of Tukwila Permit Center. Per the International Building, Residential, and Mechanical Codes as well as the Uniform Plumbing Code and/or the National Electric Code, every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire 12/19/2014. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is completed for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that your permit is not issued, we do not receive your written request for extension, or your request is denied your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Jenni °r Marshall Permi Technician Fi a o: EL14-0577 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL14-0577 DATE: 06/19/14 PROJECT NAME: BUY BUY BABY SITE ADDRESS: 17686 SOUTHCENTER PKWY X Original Plan Submittal Revision # Response to Correction Letter # before Permit Issued Revision # after Permit Issued DEPARTMENTS: icNeNi(i 01.01T1 Building Division it Fire Prevention Public Works Structural Planning Division Permit Coordinator IN PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 06/24/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) DUE DATE: 07/22/14 Approved with Conditions 1)4 Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 STERLING ELECTRICAL CONT— Page 1 of 3 CpWashington State Department of Labor & Industries STERLING ELECTRICAL CONTRS Owner or tradesperson GRAVES, JESSICA L Principals GRAVES, JESSICA L, OWNER Doing business as STERLING ELECTRICAL CONTRS WA UBI No. 602 913 810 18712 52ND AVE W LYNNWOOD, WA98037 425-774-1903 SNOHOMISH County Business type Individual License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor License specialties GENERAL License no. STERLEC910JL Effective — expiration 04/10/2009— 04/19/2015 Bond Travelers Cas and Surety Co of America Bond account no. 105407235 Received by L&I 06/22/2012 Bond history Savings No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. Active. Meets current requirements. $4,000.00 Effective date 04/07/2010 Expiration date Until Canceled https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602913810&LIC=STERLEC910JL&SAW= 11/04/2014