HomeMy WebLinkAboutPermit EL14-0622 - MILLS RESIDENCE - THERMOSTATMILLS RESIDENCE 14250 58 AVE S EL1 4-0622 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 3365901115 14250 58TH AVE S MILLS RESIDENCE ELECTRICAL OTC PERMIT Permit Number: EL14-0622 Issue Date: 6/27/2014 Permit Expires On: 12/30/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: MILLS WILLIAM S 14250 58TH AVE S , TUKWILA, WA, 98168 JAIMIE HOW 4601 S 134 PL, TUKWILA, WA, 98168 BRENNAN HEATING & A/C 4601 S 134 PL, TUKWILA, WA, 98168 BRENNHA962DU Phone: (206) 248-7980 Phone: Expiration Date: 3/31/2016 DESCRIPTION OF WORK: THERMOSTAT FOR RESIDENTIAL HEAT PUMP REVISION #1 - CIRCUIT FOR HEAT PUMP. Valuation of single family: $300.00 Valuation of mf/comm: $0.00 Type of Work: LOW VOLTAGE Fees Collected: $120.17 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Signature; Date: O 71ds'/ y I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local aws regulating construction or the performance of work. I am authorized to sign and obtain this develop -nt .ermit and agree to the conditions attached to this permit. Signat Print m Date 1-leN This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 3365901115 14250 58TH AVE S MILLS RESIDENCE ELECTRICAL OTC PERMIT Permit Number: EL14-0622 Issue Date: 6/27/2014 Permit Expires On: 12/24/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: MILLS WILLIAM S 14250 58TH AVE S , TUKWILA, WA, 98168 JAIMIE HOW 4601 S 134 PL, TUKWILA, WA, 98168 BRENNAN HEATING & A/C 4601 S 134 PL, TUKWILA, WA, 98168 BRENNHA962DU Phone: (206) 248-7980 Phone: Expiration Date: 3/31/2016 DESCRIPTION OF WORK: THERMOSTAT FOR RESIDENTIAL HEAT PUMP Valuation of single family: $300.00 Valuation of mf/comm: $0.00 Type of Work: LOW VOLTAGE Fees Collected: $120.17 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: Permit Center Authorized Signature: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Date: (Q `);7‘' `14 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this develop`nent permit and agree to the conditions attached to this permit. Signatu Print Name: J'QA^y 20n Date: 06 /2'7 J S� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** Site Address: 14250 58th Ave S, Tukwila, WA 98168 Tenant Name: Sandy Mills King Co Assessor's Tax No.: 3365901115 Suite Number: Floor: PRO; Name: Sandy Mills Address: 14250 58th Ave S City: Tukwila State: WA Zip: 98168 Name: 7aimie Address: Same as contractor City: State: Zip: Phone: Fax: Email: New Tenant: ❑ Yes ® .. No TRACTOR INT C Company Name: Brennan Heating Address: 4601 S 134th Place City: Tukwila State: WA Zip: 98168 Phone: (206) 248-7900 Fax: (206) 248-7905 Contr Reg No.: BRENNHA971 R' Exp Date: 12/29/2015 Tukwila Business License No.; BUS-0100281 Valuation of Project (contractor's bid price): $ 300 Scope of Work (please provide detailed information): T-stat for residential heat pump. Will service be altered? I Yes ❑ No Adding more than 50 amps? ❑ Yes m No Type of Use: Type of work: O New ❑ Addition 0 Service Change ❑ Remodel ❑ Tenant Improvement O Low Voltage ❑ Generator 0 Fire Alarm Telecommunication ❑ ❑ Temporary Service Property Served by: O Puget Sound Energy ❑ Seattle City Light H:\Applications\Forme-Applications On Linc\2014 Applications\Electrical Permit Application Revised 1-1-14.dnex Revised: January 2014 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea O Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $68.25 O Low voltage systems $59.85 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $65.00 ❑ Temporary service (generator) $80.90 ❑ Manufactured/mobile home service $86.25 (excluding garage or outbuilding) ❑ Carnivals $80.60 Number of concessions $10.80 ea Each ride and generator truck $10.80 ea ***EFFECTIVE JANUARY I., 2014.EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: ,, e rc..nn,y ? % Mailing Address: 4601 S 134th Place, Tukwila, WA 98168 H:\Applications\Forms-Applications On Line \2014 Applications \Electrical Permit Application Revised I-1-14.docx Revised: January 2014 bb Date: 0612-712-0/ Y Day Telephone: (206) 248-7900 City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila Receipt Number R2478 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $339.88 EL14-0622 Address: 14250 58TH AVE S Apn: 3365901115 $120.17 ELECTRICAL $114.45 PERMIT FEE SINGLE FAMILY R000.322.101.00.00 0.00 $114.45 TECHNOLOGY FEE $5.72 TECHNOLOGY FEE R000.322.900.04.00 0.00 $5.72 M14-0132 Address: 14250 58TH AVE S Apn: 3365901115 $219.71 MECHANICAL $209.25 PERMIT FEE R000.322.100.00.00 0.00 $176.75 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 TECHNOLOGY FEE $10.46 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2478 R000.322.900.04.00 0.00 $10.46 $339.88 Date Paid: Friday, June 27, 2014 Paid By: JAIMIE HOW BRENNAN HEATING AND Pay Method: CREDIT CARD 08395G Printed: Friday, June 27, 2014 11:39 AM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 6,11- 0611, Project: 11 ltAi, gAIS Type of Inspection: 6.41...... Address: /L(Z, Q q Mt' Date Called: Special Instructions: Date Wanted: 1 / .. (a.m, p.tn. Requester: Phone No: L n I goon Approved per applicable codes. D Corrections required prior to approval. iv COMMENTS: f ) 1— Inspector:, _ . ideic Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 ot-001-, Project: fl Type of Inspection: f MA/41. Address: /, 50 5 .. Date Called: Special Instructions: (" 15 fir Date Wanted: ��?j a m p.m. Requester: ff Phone No: Approved per applicable codes. L�J Corrections required prior to approval. COMMENTS: !r `Parr To tdGwl?e 0,11(td4 Of OVIDoo viler , fP Rk 4 u.ts do r l %YL ST 4.1/ / lIrtglfoSt - 144 e '-4rtit JPD'r ) kr Prf i CC- -- r ... Inspector: !PO ?4,46S Date: ° 7 /a311 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date:--] ell Plan Check/Permit Number: ❑ Response to Incomplete Letter # Response to Correction Letter # Revision # / after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: I ► l Q..ts ` 6�.(.4/1 -E� Project Address: / d (�` -'lam-� Contact Person: JWI fl/ Summary of Revision: Phone Number: dl a0 oc p)v),A10 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in TRAKiT on 6 2/0 V BRENNAN HEATING & A/C LLC Page 1 of 5 Washington State Department of Labor & Industries BRENNAN HEATING & A/C LLC Owner or tradesperson ERDAHL, DARRIN P Principals ERDAHL, DARRIN P, PARTNER/MEMBER Doing business as BRENNAN HEATING & A/C LLC WA UBI No. 602 346 866 4601 S 134TH PL SEATTLE, WA 98168 206-248-7900 KING County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor License specialties GENERAL License no. BRENNHA962DU Effective — expiration 03/31 /2004— 03/31/2016 Designated administrator Hohenstein, James L License type Electrical Administrator Bond FEDERATED MUTUAL INS CO Bond account no. 9127229 Active. Meets current requirements. Active. Meets current requirements. License no. HOHENJL906C6 $4,000.00 Received by L&I Effective date 11/04/2004 12/22/2004 Expiration date Until Canceled Savings No savings accounts during the previous 6 year period. License Violations Infraction no. EHUMI00307 Violation date Satisfied RCW/WAC https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602346866&LIC=BRENNHA962DU&SAW= 06/27/2014