Loading...
HomeMy WebLinkAboutPermit EL14-0706 - SCHOFIELD - TENANT IMPROVEMENTThis record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. EL14-0706 SCHOFIELD 16831 Southcenter Parkway DIGITAL RECORDS (DR)EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDESTHE FOLLOWING REDACTED INFORMATION Page #CodeExemptionBrief Explanatory DescriptionStatute/Rule The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern.As such, individuals’ social security Personal Information – numbers are redacted to protect those Social Security Numbers individuals’ privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW DR1Generally –5 U.S.C. sec. under section 42.56.070(1) of the Washington 42.56.070(1) 552(a); RCW State Public Records Act, which exempts under 42.56.070(1) the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information – expiration dates, or bank or other financial RCW account numbers, which are exempt from 15DR2Financial Information – 42.56.230(5) disclosurepursuant to RCW 42.56.230(5), RCW 42.56.230(45) except when disclosure is expressly required by or governed by other law. Personal Information – Redactions contain information used to prove RCW Driver’s License. –RCW identity, age, residential address, social security 42.56.230 (7a DR3 number or other personal information required to 42.56.230 & c) apply for a driver’s license or identicard. (7a & c) Redacted content contains a communication between client and attorney for the purpose of obtaining or providing legal advice exempt from RCW Attorney-Client Privilege –disclosure pursuant to RCW 5.60.060(2)(a), 5.60.060(2)(a); RCW 5.60.060(2)(a); RCW which protects attorney-client privileged DR4 RCW 42.56.070(1)communications, and RCW 42.56.070(1), which 42.56.070(1) protects, under the PRA, information exempt or prohibited from disclosure under another statute. SCHOFIELD 16831 S OUTH CENTER PKWY EL1 4-0706 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT 2623049068 16831 SOUTHCENTER PKWY Project Name: SCHOFIELD Permit Number: EL14-0706 Issue Date: 8/19/2014 Permit Expires On: 2/15/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: MATSUMI LLC % ROBERT SCHOFI 4212 HUNTS POINT DR , BELLEVUE, WA, 98004 CLINT MCCUBBIN PO BOX 2080 , SNOHOMISH, WA, 98291 NORTHLAND ELECTRIC INC 4314 103RD AVE SE , LAKE STEVENS, WA, 98258-5767 NORTHEI21879 Phone: (425) 343-2926 Phone: (425) 377-1514 Expiration Date: DESCRIPTION OF WORK: RECONFIGURE EXISTING TENANT SPACE INTO (2) SPACES. RECONFIGURE EXISTING SERVICE AND ADD 2 NEW METERS FOR EACH NEW SPACE. Valuation of single family: $0.00 Valuation of mf/comm: $15,000.00 Type of Work: TENANT IMP Fees Collected: $468.40 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 �`C�V'� Date: Permit Center Authorized Signature: V' V��� I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: �E/1 /J M(U P Dates ` 7 -f/ ` This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKC A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. / (,-I L''" 01 p(p Project No. Date Application Accepted: Date Application Expires: 1-1s-f< (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION &83 / 1/�\C0(1 OS:A/T - Pk L<;1% King Co Assessor's Tax No.: Site Address:'' / le/ 3,5 ve/ 7(1:17a , Pk/ WY Suite Number: Floor: Tenant Name: ‘54-CH'OF/ E6,1) PROPERTY OWNER Name:L. 4ei C 4j 40 ,s-C1 ` o 1 EL h Address: P 37 / E i S a S,� ' 23p0 )L-.c1, City�'EAT%/ir, State: l , i/i Zip:/OI0Z CONTACT PERSON — person receiving all project communication Name: ...p c 4 L_'—✓W - � --CGZge j if Address,pO Q,x 2 /® Zip City:5 1 /1i/ State:Am ?./ Phone 3yyz7 Fax:fj 9_^77/y Email: V/1 /'11/C/'%iflJnj/%F New Tenant: ❑ Yes X. No ELECTRICAL CONTRACTOR INFORMATION Company Name:Ai ,e27/14/A0 Ek‘C.711 C2 Address: )0 -Ecc,x 2 08 0 City Iv- 1pH0isiif/4 State:t , /4 ZiP9s2 / Phone 1 � 2 %g7'Fax ` 7h _ 1©�//� / 7ij J Contr Reg No.: xp Date: �cQtn�_;8 g 3rl J Tukwila Business License No.; t, c ! 2�C. Valuation of Project (contractor's bid price): $ % O C7 0 Scope of Work (please provide detailed information): 9 ®� �%—f z � � � /f� �� f Cfd Will service be altered? Type of Use: Type of work: ❑ New ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: APuget Sound Energy 0 Seattle City Light Yes ❑ No Adding more than 50 amps? ❑ Yes ,No ❑ Service Change ❑ Fire Alarm ❑ Remodel ❑ Telecommunication Tenant Improvement ❑ Temporary Service H:\Applications\Forms-Applications On Line\2014 Applications\Electrical Permit Application Revised I-1-14.docx Revised: July 2013 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outbuildings ❑ Low voltage systems (alarm, furnace thermostat) $152.85 $81.90 ea $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $65.00 ❑ Temporary service (generator) $80.90 ❑ Manufactured/mobile home service $86.25 (excluding garage or outbuilding) ❑ Carnivals $80.60 Number of concessions $10.80 ea Each ride and generator truck $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: a /# / / c i '(I'3 6 I / `` Day Telephone: Mailing Address: po €lax oBG S/VeV7 © /f/—/ `-6 City State H:\Applications\Forms-Applications On Line\2014 Applications\Electrical Permit Application Revised 1-1-14.docx Revised: July 2013 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID ermitTRA $90. EL14-0706 Address: 16831 SOUTHCENTER PKWY n:2623049068 90.0 ELECTRICAL $90.08 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R2699 R000.345.832.00.00 0.00 $90.08 $90.08 Date Paid: Monday, July 28, 2014 Paid By: CLINT MCCUBBIN Pay Method: CREDIT CARD 07274G Printed: Monday, July 28, 2014 12:29 PM 1 of 1 CRWYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK 37832 EL14-0706 Address: 16831 SOUTHCENTER PKWY Apn: 2623049068 $378.32 ELECTRICAL $360.30 PERMIT FEE MULTI-FAM/COMM TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2894 R000.322.101.00.00 R000.322.900.04.00 0.00 0.00 $360.30 $18.02 $18.02 $378.32. Date Paid: Tuesday, August 19, 2014 Paid By: NORTHLAND ELECTRIC INC Pay Method: CREDIT CARD 06085G Printed: Tuesday, August 19, 2014 9:15 AM 1 of 1 l?SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 6/P-I-- At, Project: Type of Inspection: iti.r Address: At f 1 t5C, pl. Date Called: Special Instructions: Date Wanted: f V3 !r p.m. Requester: Phone No: r,4 Approved per applicable codes. Corrections required prior to approval. COMMENTS: rf r ' TAJA- Inspector: I1 Date: 07/o 2 1' 7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 6.11-oN, Project:' �) /_ �1� Type of Inspection: ,�+ j f J 1/[ c�C N. Address: atvin f ss-z. pi Date Called: Special Instructions: Date Wanted:'8 2-7 / a,m, C12:11-1,;, Requester: Phone No: ❑ Approved per applicable codes. Corrections required prior to approval COMMENTS: f% y-("1- r occm›-t Inspector: ` it Date: 0�7ILQ/I( REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be,;. paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. T/I SPACE 1 T/I - 1 PANEL A 100 A 277 / 480 v 3p./ 4w 45 KVA TRANSF. 480 TO 208v 60.3 100.3 T/I - 1 PANEL B 100 A MAIN BRKR 120/208 v 3p./ 4w 100.3 T/I SPACE 2 T/I - 2 PANEL A 100 A 277 / 480 v 3p./ 4w 45 KVA TRANSF. 480 TO 208v 60.3 1 1" 3-#6 cu. 1-#8 cu. 1-#8 cu. 60 60 60 100.3 1 1-1/4" 3-#1AL. 1-#1AL. 1-#6AL. 100 100 100 125.3 1 1-1/2" 3-#1/0 XHHW AL. 1-#2AL. 1-#4AL. 125 125 125 60.3 100.3 T/I - 2 PANEL B 100 A MAIN BRKR 120 / 208 v 3p./ 4w 100.3 NEUTRAL NEW SERVICES 100.3 100.3 0 T/I #1 16831 100 A 277/480v 3p/4w 100.3 T/I #2 16833 100 A 277/480v 3p/4w 100.3 GRD. REVIEWED FOR COMPLIANCE WITH NFPA70-NEC AUG 15 2014 City of Tukwila BUILDING DIVISION EXISTING HOUSE 100 A 277/480v 3p/4w TAP SECTION 600 A' TAP SECTION ELIN-0706 EXISTING MAIN - 600 AMP 277 / 480 v 3p/4w RECEIVED CITY OF TUKWILA JUL 2 8 2014 -PERMIT-EENiER 1— a 0 w u M en 00 0 r'I 1I M 00 1-1 So. Center.TI PANEL: B - T/I # 1 PANEL SCHEDULE PROJECT : SCHOFIELD - SOUTH CENTER PANEL: A - T/I # 1 PANEL SCHEDULE PROJECT : SCHOFIELD - SOUTH CENTER 120 / 208 v. 1 PH 3 W 100 AMP MAIN BREAKER 100 AMP LOCATION : 277 / 480 v. 3 PH - 4 W 100 AMP MAIN LUG ONLY LOCATION : Ckt. No. 1 Description / Location Load (VA) Load Type CB Amp PHASE CB Amp Load Type Load (VA) Description / Location Ckt. No. Ckt. No. Description / Location Load (VA) Load Type CB Amp PHASE CB Amp Load Type Load (VA) Description / Location Ckt. No. 3 5 7 9 11 13 15 17 19 21 23 HWT - 2,250 2,250 E 30 A 20 L 1,300 LIGHTING TROFFERS X 10 2 1 B 20 R 1,800 RECEPT. X 10 4 3 SIGN CIRCUIT - SHOWROOM WINDOW - 1,500 1,800 L L 20 20 A 20 R 1,800 RECEPT. X 10 6 8 B 10 12 A 14 B 16 18 A B 20 22 c 24 Connected Load - Phase " A " 5,350 VA 45 amps Connected Load - Phase " B " 4,050 VA 34 amps Connected Load - Phase " C " 3,300 VA 28 amps TOTAL CONNECTED LOAD - TOTAL CONNECTED AMPS - 12.7 KVA 35.3 AMPS TOTAL DEMAND LOAD - TOTAL DEMAND AMPS - 13.9 KVA 38.5 AMPS 5 HVAC UNIT - Connected Load - Phase " A " Connected Load - Phase " B " Connected Load - Phase " C " TOTAL CONNECTED LOAD - TOTAL CONNECTED AMPS - 4,300 4,300 4,300 20 A B 19,300 VA 161 amps 19,300 VA 161 amps 19,300 VA 161 amps 57.9 KVA 69.7 AMPS 60 TR 15,000 15,000 15,000 TRANSF. TO 208 V. PANEL - MAXIMUM TRANSFORMER USAGE NOTED : REVIEWED FCi-I COMPLIANCE WITH NFPA 70 - NEC AUG 15 2014 City of •Tukwila BUILDING DIVISION TOTAL DEMAND LOAD - TOTAL DEMAND AMPS - 61.1 KVA 73.6 AMPS 2 4 6 Connected Total Demand Demand Loads Loads Factor Load Connected Total Demand Demand Loads Loads Factor Load L Lighting - R Receptacles - 1st - 10 kva over - 10 kva E Equipment - H Heating / Mechanical M Motors - LM Largest Motor - SB - Sub Panel - A Appliance - 4,600 - 4,600 125% 3,600 3,600 100% 100% 4,500 - 4,500 100% 100% 100% 125% 100% 100% 5,750 3,600 4,500 TOTAL - 12,700 12,700 13,850 L Lighting - R Receptacles - 1st - 10 kva over - 10 kva E Equipment - H Heating / Mechanical M Motors - LM Largest Motor - TR Transformer - A Appliance - TOTAL - 12,900 45,000 125% 100% 100% 100% 12,900 100% 100% 25% 45,000 100% 100% 12,900 3,225 45,000 57,900 70,800 RECEIVED 61,125 CITY OF TUKWILA f JUL 2 8 2014 PERMIT CENTER 2 'PANEL: B - T/I # 2 PANEL SCHEDULE PROJECT : SCHOFIELD - SOUTH CENTER PANEL: A - T/I # 2 PANEL SCHEDULE PROJECT : SCHOFIELD - SOUTH CENTER 120 / 208 v. Ckt. No. 1 3 5 7 9 11 13 15 17 19 21 23 1 PH - 3 W 100 AMP Description / Location Load (VA) Load Type MAIN BREAKER 100 AMP CB Amp PHASE CB Amp Load Type LOCATION : Load (VA) Description / Location Ckt. No. 277 / 480 v. 3 PH - 4 W 100 AMP Ckt. No. Description / Location Load (VA) Load Type MAIN LUG ONLY CB Amp PHASE CB Amp Load Type LOCATION : Load (VA) Description / Location Ckt. No. NWT 2,250 2,250 E 30 A 20 L 1,300 LIGHTING TROFFERS X 10 2 1 B 20 R 1,800 RECEPT. X 10 4 3 SIGN CIRCUIT - 1,500 L 20 20 R 1,800 RECEPT. X 10 6 5 HVAC UNIT - 4,300 4,300 4,300 H 20 A B 60 TR 15,000 15,000 15,000 TRANSF. TO 208 V. PANEL - 2 4 6 SHOWROOM WINDOW - 1,800 L 20 A 8 B 10 12 A 14 B 16 A 18 20 B 22 24 Connected Load - Phase " A " 5,350 VA 45 amps Connected Load - Phase " B " 4,050 VA 34 amps Connected Load - Phase " C " 3,300 VA 28 amps TOTAL CONNECTED LOAD - TOTAL CONNECTED AMPS - 12.7 KVA 35.3 AMPS TOTAL DEMAND LOAD - TOTAL DEMAND AMPS - 13.9 KVA 38.5 AMPS Connected Load - Phase " A " Connected Load - Phase " B " Connected Load - Phase " C " TOTAL CONNECTED LOAD - TOTAL CONNECTED AMPS - 19,300 VA 161 amps 19,300 VA 161 amps 19,300 VA 161 amps 57.9 KVA 69.7 AMPS MAXIMUM TRANSFORMER USAGE NOTED : REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC AUG 15 2014 City of Tukwila BUILDING DIVISION TOTAL DEMAND LOAD - TOTAL DEMAND AMPS - 61.1 KVA 73.6 AMPS Connected Total Demand Demand Loads Loads Factor Load Connected Total Demand Demand Loads Loads Factor Load L Lighting - 4,600 4,600 125% R Receptacles - 1st - 10 kva 3,600 3,600 100% over - 10 kva - - - 100% E Equipment - 4,500 4,500 100% H Heating / Mechanical - - 100% M Motors - - - 100% LM Largest Motor - - - 125% SB . Sub Panel - - 100% A • Appliance - - 100% 5,750 3,600 4,500 TOTAL - 12,700 12,700 13,850 L Lighting - R Receptacles - 1st - 10 kva over - 10 kva E Equipment - H Heating / Mechanical M Motors - LM Largest Motor - TR Transformer - A Appliance - TOTAL - 12,900 45,000 57,900 12,900 45,000 70,800 125% 100% 100% 100% 100% 12,900 100% - 25% 3,225 100% 45,000 10OfECEIVED CITY OF TUKWILA 61,125 JUL 2 8 2014 PERMIT CENTER 3 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL14-0706 DATE: 07/28/14 PROJECT NAME: SCHOFIELD SITE ADDRESS: 16831 SOUTHCENTER PKWY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: ovidi Building Division 1111 Public Works Fire Prevention Structural Planning Division Permit Coordinator II PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 07/29/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) DUE DATE: 08/26/14 Approved with Conditions X Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 NORTHLAND ELECTRIC INC Page 1 of 2 Washington State Department of Labor & Industries NORTHLAND ELECTRIC INC Owner or tradesperson MCCUBBIN, CLINTON M JR Principals MCCUBBIN, CLINTON M JR, PRESIDENT MCCUBBIN, SEAN T, VICE PRESIDENT MCCUBBIN, LINDA C, SECRETARY MCCUBBIN, CLINTON M JR, AGENT HECKMAN, DAVID G (End: 03/18/2011) HECKMAN, DAVID G, AGENT (End: 03/18/2011) Doing business as NORTHLAND ELECTRIC INC WA UBI No. 600 344 369 PO BOX 2080 SNOHOMISH, WA98291 425-377-1514 SNOHOMISH County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor License specialties GENERAL License no. NORTHEI21879 Effective — expiration 10/29/1979— 03/31 /2015 Designated administrator MCCUBBIN, CLINTON M JR License type Master Electrician Bond No bond accounts during the previous 6 year period. Savings (in lieu of bond) Savings account ID Active. Meets current requirements. Active. Meets current requirements. License no. MCCUBCM970RH $4,000.00 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600344369&LIC=NORTHEI21879&SAW= 08/19/2014 SCHOFIN;LD - S 0 UTH C FNT FR TI 1.1 SCHEMATIC SITE PLAN i TENANT LOCATION MAP 1.8 NOTES Oi• 01' Si. S. • +}3 1.Gai' 4ara c_; /cor pav:rtb tX i�rt 1�1 tr Epe, .to Prg ivlatsn•C rlwerri WHO. Ar3�Us`'R,tfi"Jf 1-A0-1:1 REVIEWED FOR - CONCWf NFPqMPLIA70 C. E NECITH 4io1L dity of u it UILDING I _ �rriler�. ^ it•ed FsnpLa{= 6 rRk's. ' Ii 9'1%0' Pl.ub 1* 6 12' -.6: ,s• III-V�r • -'1 LANP c,ci,tet REVISIONS No changes shall be made to the scope of v'iork without prior approval of Tukwila Building Division. f GTE: Revisions mil require a new plan submittal and may include additional plan review fees. SOUTHCENTER PKWY CENTER SITE PLAN NORTH 1.2 PROJECT DESCRIPTION 1.6 CONTACT INFO. (continued, 1.7 PROJECT STAT. (continued) Tenant Improvement in existing retail building consisting of dividing of one suite into two suites (space was originally divided into (2) tenant spaces). All interior improvements are non-structural. No change of use. No change to exterior. 1.3 TAX PARCEL TAX PARCEL NUMBER: 26230401068 1.4 LEGAL DESCRIPTION PORTION OF NE 1/4 OF SW 1/4 - BEGIN INTERSECTION OF N LINE OF NE 1/4 OF SW 1/4 4 ELY MARGIN OF PRIMARY STATE HIGHWAY NO I (SR 5) TH 5 88-05-01 E 250.21 FT TO WLY MARGIN OF MESS BROTHERS GO ROAD NO 6112 (S0UTHGENTER PARKWAY, FORMERLY 51TH AVE 5) TH 5 01-01-58 W 10.51 FT TH S 01-04-31 W 210.15 FT TAP 1035 FT N OF 5 LINE OF NE 1/4 OF SW 1/4 TH N 81-55-33 W 124.51 FT TH S 01-04-31 W 30 FT TAP 1005 FT N OF S LINE OF NE 1/4 OF 514 1/4 TH N 81-55-33 W 124.61 FT TO ELY MARGIN OF PRIMARY STATE HIGHWAY NO I (SR 5) TH N 01-01-31 E 154.12 FT TH N 13-43-26 W 28.1f1 FT TH N II-11-51 E 150.61 FT TO POB TGW VACATED 5 I68TH ST ADJOINING -- LOT I OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO c10-I-BLA RECORDING NO 10061180510 ADDRESS: Tenant Space A 16831 5outhcenter PKWY Turkwila, WA 18188 Tenant Space B 16833 Southcenter PKWY Turkwila, WA 18188 BUILDING OWNER: Schofield Limited Partnership $ B. Heron Ventures LP 111 E Louisa St. #230 Seattle, Wa g8102 LAND OWNER: Matsumi LLG 10110 66th Avenue South, Seattle, WA 18118 GB Anderson Architects, PLLG 1201 Greenwood Ave. N. Seattle, WA 18103 Attn: Gabrielle E. Muller Phone (206) 182-2ci 11 Fax (206) 182-5624 ARCHITECT/ PROJECT CONTACT: 1.7 PROJECT STAT. 1.5 CODES CODES: Tukwila Municipal Code , 2012 International Building Code with Washington State Amendments, 2012 WA State Energy Gode, Other Applicable Local 4 National Agencies. TENANT SPACE: BUILDING AREA: ZONE: USE / OCCUPANCY Existing & proposed: PARKING Existing single space: I,134 5F Gross Floor Area Proposed Suite A: Suite B: 1020 SF GFA 818 SF GFA BLDG A 13,515 SF +/- TUG Tukwila Urban Center Retail/ Mercantile; No change of use. Existing parking, no change BUILDING TYPE: NUMBER OF STORIES: OCCUPANT LOAD & EXITING: PLUMBING FIXTURES: SEPARATE PERMIT REQUIRED FOR: at Mechanical Electrical Plumbing Gas Piping Ciii of Tukwila .-.Y:, Eti''. DIVISION V-B, Sprinklered One Story Suite A: - Mercantile on grade floor areas: 30 SF GFA per occupant 861 SF / 30 SF = 21 occupants - Business areas: 100 SF GFA per occupant 104 SF / 100 = 2 occupants Total occupant load 31 ocupants Suite B: - Mercantile on grade floor areas: 30 SF GFA per occupant 838 SF / 30 SF = 28 occupants Total occupant load 28 ocupants Per IBC 1021.2 for 31 $ 28 occupants (I) exit is required. Existing: I mean of egress for each Tenant 5oace. Per IBC Table 2102.1 for M occupancy I water closet per 500 occupants per each male and female is required. Unisex Restroom per Exception Section 4, 2c:102.2: Separate facilities shall not be required in mercantile occupancies in which the maximum occupant load is 100 or less. Required: Suite A: 23 occupants / 500 = (1) one unisex restroom is allowed Existing: as required Suite B: 28 occupants / 500 = (1) one unisex restroom is allowed Existing: as required GENERAL NOTES A. These notes are in abbreviate form. The intent is to further define those areas of work not clearly delineated on the drawings. The quality of workmanship throughout shall be first class and all materials shall meet or exceed the normal industry standards applicable in each case. B. All work is to be performed in strict compliance with applicable provisions of prevailing local, state, and federal codes and ordinances, including appropriate licensing laws including any local amendments. G. Notify and consult with Architect if discrepancies are found between drawings an site conditions and/or building or zoning requirements prior to start of Work. Any consequences resulting from these discrepancies will be the Contractors sole responsibility and expense if Architect is not consulted before area in question is constructed. D. Contractor shall verify field conditions prior to start of work. If measurements or conditions differ from drawings, notify Owner prior to start of work. Bring any conflicts to the attention of the Architect whereupon a final decision will be made. Where conflicts are not brought to Architects or Owners attention during the bidding, it will be assumed Contractor has figured most expensive method. E. Tenant shall pay for Building Permit. Contractor shall obtain and pay for all additional permits required by applicable governing autiorities. F. Do not scale drawings. Use written dimensions. Where conflicts exist, notify the Architect immediately. 6. Interior wall and ceiling finishes shall not exceed Glass G: Flame Spread 16 -200 and smoke developed 0-450. FRAMING A. All materials and workmanship shall conform to the requirements of the drawings. notes, specifications, and all applicable codes and ordinances. B. All frame construction shall conform to minimum standards of I.B.G. Fastening requirements to be in accordance with Table 2304.1.1 of I.B.G. DOORS AND HARDWARE A. Unless otherwise specified, all new interior Tenant doors to be 3'-0" wide x 1'-0" high, 13/8" Solid core, MDF doors. See T.I. plan Sheet A-2 for doors and sheet A-3 for Door Type. B. All hardware to meet local code and ADA requirements. G. Unless otherwise specified, all interior tenant door hardware to be lever style interior hardware. D. Coordinate door keying with Owner and Tenant. DRYWALL FINISH A. Provide 5/8" type "x" gypsum wall board with all exposed joints and fastener heads smooth and flush with surface of board. Joints taped and prepared for application of finish. B. "Recommended Specifications for the Application and Finishing of Gypsum Board," latest edition, as published by the Gypsum Association (also published as ANSI 11.1 and "Using Gypsum Board and Ceilings", latest edition). ELECTRICAL/MECHANICAL A. Electrical/Mechanical/HVAG work shall be performed in a "Bidder -Design" manner. The Contractor shall submit such systems separately for permit. B. It is the Contractors responsibility to design systems that meet all requirements and codes. Contractor shall submit drawings, pay for, and obtain oermit and perform work in a manner that meets or exceeds the recognized workmanship standards for the industry. G. All electrical and HVAG drawings are to be submitted to the Architect for review and for coordination with the Owner and Tenant approval before performing Work. D. Electrical: Specific attention is to be paid regarding Tenant requested locations of electrical, phone and computer cabling port locations. E. HVAC. scope of work consists of installing duct work in Tenant space and connecting it to existing roof top unit. Work under separate permit. GENERAL LIGHTING NOTES A. Retail Light fixtures to be furnished and installed per Reflected Gelling Plan with light fixture schedule and cut sheets. B. It is the Contractors responsibility to design systems that meet all requirements and codes. Contractor shall submit drawings, pay for, and obtain permit and perform work in a manner that meets or exceeds the recognized workmanship standards for the industry. plan review approval Is eubject to errors and omissions. Approval of construction documents does not authorize the vioiation of any adopted code or ordinance. Receipt of approved Field ►and ., , i'; to edged: By: Date: City of Tukwila BUILDING DIVISION r 1.9 MINTY MAP 1 sjOttbp • I itrindst,:.::� PAG1' 5duti8rts 157th3,'s, nsc- is -5 170th nu Casino • h Watt .lfitand al Cnliage 1.10 SHEET A-1 i-' AN / PROJECT DATA L • OR PLAN WITH DEMO & REFLECTED CEILING PLAN SECTIONS/DETAILS RECEIVED CITY OF TUKWILA JUL 2 8 2014 PERMIT CENTER 1.11 ASSOCIATED PERMITS List of Permit Categories associated with this project: - Plumbing - Fire Alarm - Electrical - Signage - HVAG - Sprinkler 11+ 070 b CB ANDERSON ARCHITECTS PLLC 7209 Greenwood Avenue N Seattle, Washington 98103 206-782-2911 Fax 782-5624 CLIENT: SeattleRetail Christian Schofield 117 E Louisa St. #230 Seattle, Wa 98102 Phone: (206) 257-9921 SHEET TITLE: riagi PROJECT STA T. & SIT d z co O co fa C0 eft O CI V) Ca Q 1 V " 92 " 4! co, rat CO o n l� CL 0- REVISIONS: DRAWN BY: OMEtMS SCALE: NA DATE: 16 JUNE 2014 JOB NUMBER: 134-1.0 SHEET NUMBER: NOTE: 6.G. VERIFY LAYOUT $ SHALL REPORT TO THE ARGH I TEGT ANY ERRORS, DISGREPANGIES, INGONSISTENGIES OR OMISSIONS HE MAY DISCOVER. THE GONTRAGTOR 15 RESPONSIBLE FOR CORRECTING ANY ERROR AFTER THE START OF GONSTRUGTION WHICH HAS NOT BEEN BROUGHT TO THE ATTENTION OF THE ARGHITEGT. THE MEANS OF GORREGTING ANY ERROR SHALL FIRST BE APPROVED BY THE ARCHITECT. LIGHT FIXTURE SCHEDULE EXISTING STOREFRONT, NO GHANSES (E) EXISTING STOREFRONT, NO CHANGES woo -or woe woo SUITE A 1,020 SF GFA TOTAL solos soot goo aro RETAIL AREA 586 5F GFA soma vas DEMO EXISTING, TYP. P (E) A MINN NEW ELECTRICAL \\I PANEL LOCATION 1 1 swam \® mg Isms mum soon mosso atm Elm 10'-0" EXISTING BACK ROOM 275 5F GFA OFFICE 104 5F GFA 12'--1" EXISTING NEV DEMISING WALL, TYP. 2G'-0" 4%. ...,„ ♦ SUITE B 878 SF GFA TOTAL RETAIL AREA 485 5F GFA 53'-14" EXISTING NEW ELECTRICAL PANEL LOCATION BACK ROOM 350 SF GFA EXIT ACCESS TRAVEL DISTANCE 58 LF sumi 1 1 1 I 1 I I RESTROOM- - - — m !Maki MIMI (E) 1 1 J REST' ' 0 315F GFA ADJACENT TENANT "LAMPS PLUS" RETAIL EXISTING ADA RESTROOMS SYMBOL NO. DESCRIPTION LAMP MODEL NO. MANUF. WATTAGE EXISTING FIXTURE TO REMAIN (2) 32W TS COOPER/ METALUX OR APPR. EQUAL —�� EXISTING FIXTURE TO REMAIN (2) 321A1 TS GOOPER/ METALUX OR APPR. EQUAL 1 1 •E A EMERGENCY DUAL LAMP FIXTURE WITH BATTERY BACK-UP (2) 5W 6V DG LZ SERIES LITEFORMS GOLL. HUBBELL DUAL-LITE B GOMBINATION EXIT SIGN $ EMERGENCY PATH LIGHT (3) 51AI 6V DG LT SERIES LITEFORMS LOLL. HUBBELL DUAL-LITE EXIT NOTES: I. DAYLIGHT ALL DAYLIGHTED SENSING 2. PROVIDE 3. LIGHT SPRINKLERS. ZONE GONTROL: GOMPLIANGE 15 REQUIRED ZONES SHALL BE PROVIDED WITH WITH PER WSEG SECTION G405.2.2.3: INDIVIDUAL DAYLIGHT- OR OCCUPANT - OF GENERAL AREA LIGHTING. NIGHT SAFETY. OTHER CEILING ITEMS SUCH AS HVAG OR GONTROLS, WHIGH CONTROL THE LIGHTS INDEPENDANT ONE ALWAYS -ON LIGHT IN SUITE FOR FIXTURE LOCATIONS TAKE PRIORITY OVER ADJACENT TENANT "LAMPS PLUS" RETAIL RETAIL AREA SGALE: I/4" = I' 878 SF GFA TOTL RETAIL AREA ADJACENT TENANT "LAMPS PLUS" RETAIL 61'-2" EXISTING RES TO IN OFFICE REFLECTED CEIL/NGOLAN SCALE: 1/4" = I' WALL LEGEND EXISTING WALLS NEW WALLS NON -RATED WALLS TO BE DEMOLISHED O DOOR TYPE (E) DOOR TYfi E BACK ROOM RESTROOM. RESTROOM REVIEWED 1-Ut-1 COMPLIANCE WITH NFPA 70 - NEC AUG 15 2014 City of Tukwila BUILDING DIVISION I ADJAC AIL US" RECEIVED CITY OF TUKWILA JUL 2$20' 4 PERMIT CENTER ORIGIONAL SHEET SIZE 24" x 36" COPYRIGHT GB ANDERSON ARCHITECTS. STAMP APPEARS ON THIS SHEET CB ANDERSON ARCHITECTS 7209 Greenwood Seattle, Washington nc,,....) cb I- c-') 206-782-2911 Fax PLLC Avenue N 98103 782-5624 CLIENT: SeattleRetail Christian Schofield 117 E Louisa St. #230 Seattle, Wa 98102 Phone: (206) 257-9921 SHEET TITLE: FLOOR PLAN PROJECT: Schofield - Southcenter TI 16831 & 16833 Southcenter Pkwy Tukwila, WA 98188 REVISIONS: DRAWN BY: 6M $ MS SCALE: 1/4" = I' DATE: 16 JUNE 2014 JOB NUMBER: 1347.0 SHEET NUMBER: <A> 3'-0" A-3 N OFFICE DOOR DOOR NOTES: I) FRAME TO BE 18 GA. HOLLOW METAL, PAINTED PER PAINT SCHEDULE 2) ALL DOOR SLAB COMPONENTS TO BE 13/8" SOLID GORE PAINT GRADE HARDWARE NOTES: I) ALL HARDWARE TO MEET LOCAL GODES AND A.D.A. 2) CLOSER BY NORTON, 1300BG LIGHT COMMERCIAL OR APPROVED EQUAL 2) ALL DOOR KNOBS TO BE LEVER STYLE 3) PROVIDE PRIVACY LOGKSET. MANUFACTURER, MODEL 4 FINISH TO BE APPROVED BY OWNER 4) PROVIDE MATCHING WALL STOP AS NEEDED 5) PROVIDE GOAT HOOK ON DOOR, ADA HEIGHT OF 48" A.F.F. DOOR TYPE A SCALE: 1/2" = 1'-O" DOUBLE 2X4 MOP 511)05 CAULK CONTINUOUS EA SIDE AT ACOUSTICAL HALL TYPES ONLY STL FRAME V DOOR HEAD SCALE: I I/2" = 1'-O" DOOR SILENCERS OR SMOKE SEAL POOR AS SCHEDULED DOUBLE 2x WOOD STUDS DOOR JAMB SCALE: 1 1/2" = I'-O" GAULK GONTINUOUS EA SIDE AT ACOUSTICAL WALL TYPES ONLY ANCHOR CLIPS STL FRAME DOOR SILENCERS OR SMOKE SEAL DOOR AS SCHEDULED RUNNER FASTENED IN/ SGREWS TO STUDS (AT HEIGHT FERMI TING SCREW ATTACHMENT OF FAG INGS) LOGATE JAMB ANCHOR CLIPS ABOVE HINGE REINFORCEMENTS (8) JUST BELOW TOP REINFORCEMENTS -- CLIPS ON STRIKE SIDE TO OGGUR DIRECTLY OPPOSITE OF HINGE SIDE } ELEVATION: VERTICAL SECTION THRU FRAME WOOD 2x4 STUDS FLOOR ANGHOR CLIPS SEGURED TO FLOOR IN/ NO LESS THAN (2) SUITABLE FASTENERS (EXGEPT GONG 4 MASONRY WALLS) SPAGED NO LESS THAN 3" APART DOOR ANCHOR LOCATION N X w EXISTING BEAM AND WALL EXISTING ROOF ff INSULATION TO REMAIN EXISTING NEW BRACING EXISTING DOOR / EXISTING LAY -IN GEINLING, NO CHANGES SUITE A NEW DEMISING HALL EXISTING LAY -IN GEINLING, NO CHANGES SUITE B NEW DOOR / EXIST'G. ROOF STRUCTURE 4 INSULATION EXISTING JDaL / DEMISING WALL SCALE: I" = I' ADD BRACING 2x4 WOOD STUD DIAL. BRACE 48" 0.G., STAGGER DIREGTION EXISTING LAY -IN GEILING VERIFY FIRE BLOCKING © MAX 10' AFF 2X6 WOOD STUDS 24" O.G. (I) LAYER 5/8" GWB ON EA. SIDE, TYP. 2X6 BOTTOM PLATE - SECURE TO SLAB WITH 0.145" POWER -ACTUATED FASTENERS 24" 0.G. WITH I" EMBEDMENT,TYP. SECTION THROUGH TENANT SPACES SCALE: 3/8" = I' A34 CLIP, TYP. 1/2" 8-18 PAN HEAD FRAMING FRAMING SGREWS, TWO PER CONNECTION, TYP. EXIST'G. INSULATION S II I8GA3"X3' MTL. AN& INTERIOR WALL SCALE: 1 1/2" = 1'-0" EXIST'G. ROOF JOIST 2X4 WOOD STU BRAG ING REVIEWED FOR COMPLIANCE WITH NFPA70-NEC AUG 15 2014 City ®f Tukwila -_ BUILDING DIVisloN RNATE GUT N IL @ MTL. ANGLE P. EXISTING SUSPENDED CEILING SYSTEM 10'-0" AFF (VERIFY HEIGHT) (I) LAYER 5/8" TYPE X GWB ON EA. SIDE, TYP. NEW 2x4 WOOD STUD 24" 0.G., TYP. RECEIVED CITY OF TUKWILA JUL 2 8 2014 PERMIT CENTER 2X6 BOTTOM PLATE - - SECURE TO SLAB WITH 0.145" POWER -ACTUATED FASTENERS @ 24" 0.G. WITH I" EMBEDMENT,TYP. CB ANDERSON ARCHITECTS 7209 Greenwood Seattle, Washington nr1-- Piic Avenue N 98103 206-782-2911 Fax 782-5624 CLIENT: SeattleRetall Christian Schofield 117 E Louisa St. #230 Seattle, Wa 98102 Phone: (206) 257-9921 SHEET TITLE: DETAILS PROJECT: Schofield - Southcenter TI 16831 & 16833 Southcenter Pkwy Tukwila, WA 98188 REVISIONS: DRAWN BY: GM MS SCALE: 1/4" = 1' DATE: 16 JUNE 2014 JOB NUMBER: 134-1.0 SHEET NUMBER: