HomeMy WebLinkAboutPermit EL14-0874 - CENTURY LINK - FEED BREAKER, PANEL AND BRANCH WIRINGCENTURY LINK
3511 S 120 PL
EL1 4-0874
Parcel No:
Address:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.eov
1023049069
3511 S 120TH PL BLDG 6
Project Name: CENTURY LINK
ELECTRICAL PERMIT
Permit Number: EL14-0874
Issue Date: 9/24/2014
Permit Expires On: 3/23/2015
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
SABEY CORPORATION
12201 TUKWILA INTL BLVD 4THFL,
SEATTLE, WA, 98168
JEFF JOHNSON
11816 NE 116 ST, KIRKLAND, WA,
98034
JOHNSON ELECTRIC INC
11816 NE 116TH ST, KIRKLAND, WA,
98034
JOHNSEI384RU
1/1
Phone: (425) 864-4067
Phone: (425) 821-8226
Expiration Date:
DESCRIPTION OF WORK:
INSTALL 60 AMP SUB FEED BREAKER IN EXISTING 480 VOLT PANEL. INSTALL NEW FEEDER TO NEW 45 KVA
TRANSFORMER. INSTALL NEW 125 AMP MB PANEL. PROVIDE BRANCH WIRING FOR NEW RECTIFIERS.
Valuation of single family: $0.00
Valuation of mf/comm: $6,000.00
Type of Work: ADDITION
Fees Collected: $261.30
Electrical Service Provided by: SEATTLE CITY LIGHT
Water District: 125
Sewer District: VALLEY VIEW SEWER SERVICE
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
2012
2012
2012
2012
International Fuel Gas Code:
WA Cities Electrical Code:
WA State Energy Code:
2012
2014
2012
Permit Center Authorized Signature:
Date: . f- 1-i-1
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature: Date: et •-2.. . 1 LI
Print Name: J 4-4-- (---ts\.AN S (fr..
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or
if the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***ELECTRICAL PERMIT CONDITIONS***
2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical
Inspector at each work site.
3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical
Inspector.
4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations,
Chapter 296-46B WAC.
5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts
of the building, such equipment shall not be concealed until it has been inspected and approved by the
Electrical Inspector.
6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any
violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related
documentation that presumes to grant this authority are therefore not valid.
7: Any change in the scope of work described by the electrical work permit shall require additional work
permits. Where approved plans have been issued, revisions to the plans and additional review may be
required.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
2100 ELECTRICAL FINAL
7003 ROUGH -IN ELECTRICAL
7002 SERVICE
7001 UNDERGROUND/SLAB
CITY OF TUKR��_.
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Electrical Permit No.
Project No.
Date Application Accepted:
Date Application Expires:
(For office use only)
bInti
tt'
IC
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
Site Address: 3511 S. 120Th Place, Bldg 6
Tenant Name: Century Link
PROPERTY OWNER
Name: Centu Link GR. ( 00
Address: 3 1 S. 120Th Place, Bldg 6 I2-20 t -n6
City: Tukwila State: WA Zip: 98168
CONTACT PERSON — person receiving all project
communication
1,
Name: �erJe.-k—,,)0 N"spr!
Address: 11816 NE 116th St
City: Kirkland State: WA
Zip: 98034
Phone. 821-8226 Fax:
821-4836
(425) (425)
Email: 425— $4.4,LAO ,-"\--
King Co Assessor's Tax No.: 0E 0t-k - twit -)1
Suite Number: Floor:
New Tenant: ❑ Yes ❑✓ ..No
ELECTRICAL CONTRACTOR INFORMATION
Company Name: Johnson Electric, Inc
Address: 11816 NE 116th St
City: Kirkland State: WA Zip: 98034
Phone: (425) 821-8226 Fax: (425) 821-4836
Contr Reg No.: JOHNSEI384RU Exp Date: 11/20/2015
Tukwila Business License No.;
n :0
Valuation of Project (contractor's bid price): $ 6,000
Scope of Work (please provide detailed information): Install 60A sub feed breaker in existing 480V panel.
install new feeder to new 45KVA transformer. Install new 125A MB panel. Provide branch wiring for new
rectifiers.
Will service be altered? ❑ Yes ❑✓ No
Adding more than 50 amps? ❑✓ Yes ❑ No
Type of Use: Commercial
Type of work:
❑ New ❑✓ Addition 0 Service Change 0 Remodel 0 Tenant Improvement
O Low Voltage 0 Generator 0 Fire Alarm 0 Telecommunication ❑ Temporary Service
Property Served by:
O Puget Sound Energy ❑ Seattle City Light
H: Applications\Forms-Applications On Line\2014 Applications\Electrical Permit Application Revised 1-1-14.docx
Revised: January 2014
bh
Page 1 of 2
RESIDENTIAL
NEW RESIDENTIAL SERVICE
❑ New single family dwellings $152.85
(including an attached garage)
❑ Garages, pools, spas and outbuildings $81.90 ea
❑ Low voltage systems
(alarm, furnace thermostat) $59.85 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
❑ Service change or alteration $81.90
(no added/altered circuits)
❑ Service change with added/altered circuits $81.90
number of added circuits $11.55 ea
❑ Circuits added/altered without service change $54.60
(up to 5 circuits)
❑ Circuits added/altered without service change $54.60
(6 or more circuits) $7.65 ea
❑ Meter/mast repair $68.25
❑ Low voltage systems $59.85
(alarm, furnace thermostat)
MULTI -FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑ Temporary service (residential) $65.00
❑ Temporary service (generator) $80.90
❑ Manufactured/mobile home service $86.25
(excluding garage or outbuilding)
❑ Carnivals $80.60
Number of concessions $10.80 ea
Each ride and generator truck $10.80 ea
***EFFECTIVE JANUARY 1, 2014 EACH
PERMIT WILL BE ASSESSED A 5%
TECHNOLOGY FEE***
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR ELECTRICAL CONTRACTOR:
Signature:
Print Name:
Randy Dre er
Mailing Address: 11816 NE 116th Street, Kirkland, WA 98034
Date: 09/03/2014
Day Telephone: (425) 821-8226
City
State Zip
H:\Applications\Forms-Applications On Line\2014 Applications\Electrical Permit Application Revised 1-1-14.docx
Revised: January 2014
bh
Page 2 of 2
r4.
"----41ILA 11
,t;
„Ls.
\ _
N. 2908 ---
DESCRIPTIONS
PermitTRAK
Cash Register Receipt
City of Tukwila
ACCOUNT
QUANTITY PAID
61
EL14-0874 ` Address: 35115120TH PL BLDG'
n:1023049069
$261.30
ELECTRICAL
$251.25
PLAN CHECK FEE
R000.345.832.00.00
0.00
$50.25
PERMIT FEE MULTI-FAM/COMM
R000.322.101.00.00
0.00
$201.00
TECHNOLOGY FEE
S 10.05
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R3068
R000.322.900.04.00
0.00
$10.05
$261.30
Date Paid: Wednesday, September 17, 2014
Paid By: JEFFREY JOHNSON JOHNSON ELECTR
Pay Method: CREDIT CARD 04021G
Printed: Wednesday, September 17, 2014 3:47 1 of 1
AM
CRWSYSTEMS
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. P MIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367b
Permit Inspection Request Line (206) 438-9350
Project: fi , __,
fh\rivkl bat&
Type of Inspection: 64_
Address: ...11 _51 12.0 pi..._
Date Called:
r
_
Special Instructions:
Date Wanted:
12---/t1
.
ceSr.m.'
...a.".
Requester:
Phone No:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
•
F
i2jit (01
t
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
11/6d6eN
Date:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
64(1-6T7G1
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd,, #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
6&ItraiLl 1-t Ajn-
Type of Inspection: FtAmt._
Address: 3c 1 za ri
t 5. t--.
Date Called:
Special Instructions:
OGIVt/ 4 nr1(
Date Wanted:
all i P.m.
Requester:
Phone No: ...---
liA go 1077
EjApproved per applicable codes. Corrections required prior to approval.
CO
ENTS:
Inspector
Date: /2 ihl
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Cali to schedule reinspection.
6300 Southcenter Blvd., #100, Tukwila. WA 98188
Permit Inspection Request Line (206) 431-2451
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
6f1- DY1y
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
(206) 431-3670
Project: J
C'S ► V L l..'r f `-
Type of Inspection:
IV41
Address:
Date Called:
Special Instructions:
Z; o0
Date Wanted:
`�'%m
Z
p.m.
Requester:
i
'"
Phone No:
Approved per applicable des.
LCorrections required prior to approval.
COMMENTS:
%1 I t f '
' V
t
?ffriii PO-N/61
Inspector:j"
r
Date:
ogki
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
Otwiltek
(E) PNL "OF"
(N) PNL "LOF-1 "
(N) XFMR
FILE COPY
Permit No..EL10g149
Plan review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Field C;y and conditions is acknowledged:
By:
Date: °l• Z`E• k`i
City of Tukwila
BUILDING DIVISION
REVISIONS
No changes shall bel► made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
1-v vLs't-orwve4' &ecO 4 o f
0 v ttr GV w'cv .+ vti
A--e4A Vine.
v4oc,A- k 4--k) cyc-
-}voty\54 rwver
SEPARATE PERMIT
REQUIRED FOR:
LI'Mechanic:ai
❑ Electrical
i PtumbIrg
i'1Gas Piping
City of Tukwila
BUILDING DIVISION
FLOOR PLAN
Tenan ._
Century Link
3511 S. 120th Place, Bldg 6
Tukwila, WA 98168
Electrical Contractor:
Johnson Electric, Inc
11816 NE 116th St
Kirkland, WA 98034
425-821-8226
ONE -LINE
REVIEWED .FOR
COMPLIANCE WITH
NFPA 70 - NEC
SEP 12 2014
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
SEP 0 9 2014
PERMIT CENTER
(N) LOF-1
SCALE: 1/8"=1'0"
NTS
Eut-1 o rig
(Existing Panel) PANEL: OF
PROJECT:
LOCATION:
FED VIA:
Century Link
VOLTS: 2771480 3PH, 4W
DATE: 9/3/14
Fiber Hub / Bldg 6
Pnl A6
CIR.
LOAD
PNL.AMPS
MAX AMPS
M.L.O.
MAIN C.B.
MAIN FU.
FLUSH
SURFACE
S.E. LABLE
A.I.C.
BOND GRND.
ISO GRND.
FEED THRU
SUB FEED
TOP FEED
BTM FEED
LOAD SUMMARY
REC. KVA
HEAT KVA
MOTOR KVA
LTG KVA
OTHER KVA
TOTAL
CONN. KVA
CONN.AMPS
DEMAND KVA
DEMAND AMPS
ADJUSTED RECEPTACLE
(FIRST 10KW @ 100%,
LARGEST MOTOR
REMAING MOTOR
REVIEVI
COMPLIA
NFPA
SEP 1
SEP
200
200
NOTE:
DESCRIPTION
AMPS
POLE
NUM.
PH
REC.
HEAT
MOTOR
LTG
OTHER
TOTAL
Rectifier#1
20
2
1
A
0
0
0
0
1.8
1.8
X
200
Rectifier #1
20
2
3
B
0
0
0
0
1.8
1.8
B
Spare
20
2
5
C
0
0
0
0
0
0
Spare
20
2
7
A
0
0
0
0
0
0
X
Spare
20
2
9
B
0
0
0
0
0
0
Spare
20
2
11
C
0
0
0
0
0
0
18K
Panel LOF Sub Feed Breaker
60
3
13
A
0
0
0
0
7.2
7.2
60
3
15
B
0
0
0
0
7.2
7.2
60
3
17
C
0
0
0
0
7.2
7.2
TVSS
20
3
19
A
0
0
0
0
0
0
,a.
City of
�J
BUILDING
20
3
21
B
0
0
0
0
0
0
20
3
23
C
0
0
0
0
0
0
X
Space
25
A
0
0
0
0
0
0
A
Space
27
B
0
0
0
0
0
0
C TOTAL
Space
29
C
0
0
0
0
0
0
Space
31
A
0
0
0
0
0
0
0
0
0
0.00
Space
33
B
0
0
0
0
0
0
0
0
0
0.00
Space
35
C
0
0
0
0
0
0
6.6
6.6
6.6
19.80
Space
37
A
0
0
0
0
0
0
0
0
0
0.00
Space
39
B
0
0
0
0
0
0
9
9
7.2
25.20
Space
41
C
0
0
0
0
0
0
15.6 15.6 13.8 45.00
Spare
20
2
2
A
0
0
0
0
0
0
LOAD
@ 50%)
@ 100%
@125%
@ 100%
@ 125%
@ 100%
TUKWILA
Spare
20
2
4
B
0
0
0
0
0
0
45.00
Spare
20
1
6
C
0
0
0
0
0
0
54.19
Spare
20
1
8
A
0
0
0
0
0
0
47.48
Spare
20
1
10
B
0
0
0
0
0
0
57.17
Spare
20
1
12
C
0
0
0
0
0
0
REMAINING
HEATING
LOAD =
LOAD
LIGHTING
OTHER
TOTAL
CITY
AC-2
20
3
14
. A
0
0
3.3
0
0
3.3
AC-2
20
3
16
B
0
0
3.3
0
0
3.3
0.00
AC-2
20
3
18
C
0
0
3.3
0
0
3.3
0.00
AC-1
20
3
20
A
0
0
3.3
0
0
3.3
9.9
12.38
AC-1
20
3
22
B
0
0
3.3
0
0
3.3
RECEIVED
OF
9.90
AC-1
20
3
24
C
0
0
3.3
0
0
3.3
0.00
Spare
20
3
26
A
0
0
0
0
0
0
25.20
Spare
20
3
28
B
0
0
0
0
0
0
47.48
Spare
20
3
30
C
0
0
0
0
0
0
Space
32
A
0
0
0
0
0
0
Space
34
B
0
0
0
0
0
0
Space
36
C
0
0
0
0
0
0
Space
40
AB
0
0
0
0
0
0
Space
40
B
0
0
0
0
0
0
Space
42
C
0
0
0
0
0
0
NOTES SEP 0 9 2014
1
2
4 3 PERMIT CENTER
ED .FOR
NCE WITH
0-NEC
2 2014
ukwila
DIVISION
1
(New Panel) PANEL: LOF-1
PROJECT:
LOCATION:
FED VIA:
Century Link
VOLTS: 1201208 3PH, 4W
DATE: 9/3/2014
Fiber Hub / Bldg 6
Pnl OF
CIR.
LOAD
PNL.AMPS
MAX AMPS
M.L.O.
MAIN C.B.
MAIN FU.
FLUSH
SURFACE
S.E. LABLE
A.I.C.
BOND GRND.
ISO GRND.
FEED THRU
SUB FEED
TOP FEED
BTM FEED
LOAD SUMMARY
REC. KVA
HEAT KVA
MOTOR KVA
LTG KVA
OTHER KVA
TOTAL
CONN. KVA
CONN.AMPS
DEMAND KVA
DEMAND AMPS
ADJUSTED RECEPTACLE
(FIRST 10KW @ 100%,
LARGEST MOTOR
REMAING MOTOR
CITY
C
_.
REVIE
COMPL
NFPP
SEP
125
125
NOTE:
DESCRIPTION
AMPS
POLE
NUM.
PH
REC.
HEAT
MOTOR
LTG
OTHER
TOTAL
Rectifier
25
2
1
A
0
0
0
0
1.8
1.8
125
I
Rectifier
25
2
3
B
0
0
0
0
1.8
1.8
B
Rectifier
25
2
5
C
0
0
0
0
1.8
1.8
Rectifier
25
2
7
A
0
0
0
0
1.8
1.8
X.
Rectifier
25
2
9
B
0
0
0
0
1.8
1.8
Rectifier
25
2
11
C
0
0
0
0
1.8
1.8
/8 &
13
A
0
0
0
0
0
0
15
B
0
0
0
0
0
0
17
C
0
0
0
0
0
0
19
A
0
0
0
0
0
0
21
B
0
0
0
0
0
0
City c
• BUILDIN
23
C
0
0
0
0
0
0
X
25
A
0
0
0
0
0
0
A
27
B
0
0
0
0
0
0
TOTAL
29
C
0
0
0
0
0
0
31
A
0
0
0
0
0
0
0
0
0
0.00
33
B
0
0
0
0
0
0
0
0
0
0.00
35
C
0
0
0
0
0
0
0
0
0
0.00
37
A
0
0
0
0
0
0
0
0
0
0.00
39
B
0
0
0
0
0
0
7.2
7.2
7.2
21.60
41
C
0
0
0
0
0
0
7.2 7.2 7.2 21.60
Rectifier
25
2
2
A
0
0
0
0
1.8
1.8
LOAD
@ 50%)
@ 100%
@125%
@ 100%
@ 125%
@ 100%
•.
Rectifier
25
2
4
B
0
0
0
0
1.8
1.8
21.60
Rectifier
25
2
6
C
0
0
0
0
1.8
1.8
60.03
Rectifier
25
2
8
A
0
0
0
0
1.8
1.8
21.60
Rectifier
25
2
10
B
0
0
0
0
1.8
1.8
60.03
Rectifier
25
2
12
C
0
0
0
0
1.8
1.8
REMAINING
HEATING
LOAD =
LOAD
LIGHTING
OTHER
TOTAL
RECEIVED
OF
14
A
0
0
0
0
0
0
16
B
0
0
0
0
0
0
0.00
18
C
0
0
0
0
0
0
0.00
20
A
0
0
0
0
0
0
0
0.00
22
B
0
0
0
0
0
0
TUKWILA
0.00
24
C
0
0
0
0
0
0
0.00
26
A
0
0
0
0
0
0
21.60
28
B
0
0
0
0
0
0
21.60
30
C
0
0
0
0
0
0
32
A
0
0
0
0
0
0
34
B
00
00
00
00
00
0
36
C
36
A
o
0
0
0
0
o
40
B
0
0
0
0
0
0
42
C
0
0
0
0
0
0
SEP 0 9
NOTES 2314
1.
2.
3: PERMIT CENTER
4.
_ ERMf T COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: EL14-0874
PROJECT NAME: CENTURY LINK
DATE: 09/09/2014
SITE ADDRESS: 3511 S 120 PL, BLDG 6
X Original Plan Submittal
Response to Correction Letter #
Revision #-
Revision #
before Permit Issued
after Permit Issued
DEPARTMENTS:
Building Division
Public Works
Fire Prevention
Structural
n
Planning Division
Permit Coordinator
PRELIMINARY REVIEW:
Not Applicable n
(no approval/review required)
DATE: 09/11/14
Structural Review Required
REVIEWER'S INITIALS: DATE:
n
APPROVALS OR CORRECTIONS:
Approved
Corrections Required n Denied
(ie: Zoning Issues)
(corrections entered in Reviews)
Notation:
Approved with Conditions
DUE DATE: 10/09/14
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg ❑ Fire 0 Ping ❑ PW ❑
BUILDING OFFICIAL
APPROVAL FOR ISSUANCE
sSIGN DATE
JOHNSON ELECTRIC INC
Page 1 of 4
inWashington State Department of
Labor & Industries
JOHNSON ELECTRIC INC
Owner or tradesperson
JOHNSON, DANIEL B JR
Principals
JOHNSON, DANIEL B JR
JOHNSON, DANIEL B SR
JOHNSON, JEFFREY J
JOHNSON JR, DANIEL B, AGENT
Doing business as
JOHNSON ELECTRIC INC
WA UBI No.
600 361 519
11816 NE 116TH ST
KIRKLAND, WA98034-7105
425-821-8226
KING County
Business type
Corporation
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Electrical Contractor Active.
Meets current requirements.
License specialties
GENERAL
License no.
JOHNSEI384RU
Effective — expiration
12/31 /1962-11 /30/2014
Designated administrator
JOHNSON, DANIEL B
Active.
Meets current requirements.
License type License no.
Electrical Administrator JOHNSDB250MT
Bond
HARTFORD INS GROUP $4,000.00
Bond account no.
RN5038112
Received by L&I
11/20/1980
Savings
No savings accounts during the previous 6 year period.
Effective date
11/20/1980
Expiration date
Until Canceled
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600361519&LIC=JOHNSEI384RU&SAW= 09/24/2014