HomeMy WebLinkAboutPermit EL14-1241 - ZAYO GROUP - PANELS, ATS AND POWER FOR DOORSZAYO GROUP
3311 S 12OT'PL
EL14-1241
Parcel No:
Address:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
ELECTRICAL PERMIT
1023049078 Permit Number:
3311 S 120TH PL 120TH
Project Name: ZAYO GROUP
Issue Date:
Permit Expires On:
EL14-1241
7/27/2015
1/23/2016
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
SABEY CORPORATION
4TH FLOOR 12201 TUKWILA INTL
BLVD, SEATTLE, WA, 98168
JASON PECOTTE
12828 NORTHRUP WY, BELLEVUE,
WA, 98005
TITAN ELECTRIC INC
12828 NORTHUP WAY SUITE 205,
BELLEVUE, WA, 98005
TITANEI963OB
11/
Phone: (206) 551-7195
Phone: (206) 633-2811
Expiration Date: 9/2/2016
DESCRIPTION OF WORK:
ADD (2) 225 AMP PANELS, RECOMMISSION ATS A & B AND INSTALL LOW VOLTAGE POWER FOR DOORS
Valuation of single family: $0.00
Valuation of mf/comm: $18,000.00
Type of Work: TENANT IMP
Fees Collected: $537.42
Electrical Service Provided by: SEATTLE CITY LIGHT
Water District: 125,TUKWILA
Sewer District: VALLEY VIEW SEWER SERVICE
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
2012
2012
2012
2012
2012
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
WA State Energy Code:
2014
2014
2014
2012
Permit Center Authorized Signature:
-�W`-'r.aAl Date: -7- -7-1 `�
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating cstru • r the performance of work. I am authorized to sign and obtain this
development permit and a to . ditions attached to this permit.
Signature: Date:
Print Name:
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
<NONE>
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
2100 ELECTRICAL FINAL
7003 ROUGH -IN ELECTRICAL
7002 SERVICE
7001 UNDERGROUND/SLAB
CITY OF TUKif 1
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Electrical Permit No.
Project No.
Date Application Accepted:
Date Application Expires:
1�. 31- (1-f
(For office use only)
30 1
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
King Co Assessor's Tax No.:
Site Address: 3311 S. 120th Pl. Suite Number: 120 Floor:
Tenant Name:
Zayo Group LLC
PROPERTY OWNER
Name: Zayo Group LLC
Address: 3311 S. 120th Pl. Suite 120
City: Tukwila State: WA
Zip: 98168
CONTACT PERSON — person receiving all project
communication
Name: Jason Pecotte
Address: 12828 Northup Way Suite 205
City: Bellevue State: WA
Zip: 98005
Phone: (206) 551-7195 Fax: (206)
374-2128
Email: Jasonp@titanelectric.net
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
Job 149241: Recommission ATS A&B and install low voltage power for doors
New Tenant: ❑ Yes .. No
ELECTRICAL CONTRACTOR INFORMATION
Company Name: Titan Electric
Address: 12828 Northup Way Suite 205
City: Bellevue State: WA Zip: 98005
Phone: (206) 633-2811 Fax: (206) 374-2128
Contr Reg No.: 602-250-925 Exp Date: 12/31/2014
Tukwila Business License No.: Bus-0992893
Ackd (2) ZzsA
Will service be altered? ❑ Yes
Type of Use: Commercial
PcsavNeAS
❑✓ No Adding more than 50 amps?
Type of work:
❑ New ❑ Addition ❑ Service Change
E Low Voltage ❑ Generator ❑ Fire Alarm
Property Served by:
O Puget Sound Energy ❑ Seattle City Light
H:.ApplicationsForms-Applications On Line201 I Applications.:Electrical Permit Application Revised 8-9-I I.docx
Revised: August 2011
bh
❑ Remodel
❑ Telecommunication
X Yes No
O Tenant Improvement
❑ Temporary Service
Page 1 of 2
RESIDENTIAL
NEW RESIDENTIAL SERVICE
❑ New single family dwellings $152.85
(including an attached garage)
❑ Garages, pools, spas and outbuildings $81.90 ea
❑ Low voltage systems
(alarm, furnace thermostat) $59.85 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
❑ Service change or alteration $81.90
(no added/altered circuits)
❑ Service change with added/altered circuits $81.90
number of added circuits $11.55 ea
❑ Circuits added/altered without service change $54.60
(up to 5 circuits)
❑ Circuits added/altered without service change $54.60
(6 or more circuits) $7.65 ea
❑ Meter/mast repair $68.25
❑ Low voltage systems $59.85
(alarm, furnace thermostat)
MULTI -FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑ Temporary service (residential) $63.00
❑ Temporary service (generator) $78.75
❑ Manufactured/mobile home service $84.00
(excluding garage or outbuilding)
❑ Carnivals $78.75
Number of concessions $10.50 ea
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR ELECTRICAL CONTRACTOR:
Signature��
Date:
12/10/2014
Print Name: Titan Electric/Kristie Dougherty Day Telephone: (425) 250-3595
Mailing Address: 12828 Northup Way Suite 205 Bellevue WA 98103
City State Zip
H:\Applications\Forms-Applications On Line\2011 Applications'Electrical Permit Application Revised 8-9-11.docx
Revised: August 2011
bh
Page 2 of 2
Cash Register Receipt
City of Tukwila
DESCRIPTIONS ACCOUNT
PermitTRAK
QUANTITY
PAID
$537.42
EL14-1241 Address: 3311 S 120TH PL 120TH Apn: 1023049078
$537.42
ELECTRICAL
$516.75
PLAN CHECK FEE
R000.345.832.00.00
0.00
$103.35
PERMIT FEE MULTI-FAM/COMM
R000.322.101.00.00
0.00
$413.40
TECHNOLOGY FEE
$20.67
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R3890
R000.322.900.04.00
0.00
$20.67
$537.42
Date Paid: Wednesday, December 31, 2014
Paid By: TITAN ELECTRIC INC
Pay Method: CHECK 17964
Printed: Wednesday, December 31, 2014 1:37 PM 1 of 1
SYSTEMS
City of Tukwila
Department of Community Development
12/1/2015
JASON PECOTTE
12828 NORTHRUP WY
BELLEVUE, WA 98005
RE: Permit No. EL14-1241
ZAYO GROUP
3311 S 120 PL STE 120
Dear Permit Holder:
Jim Haggerton, Mayor
Jack Pace, Director
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric
Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null
and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if
the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 1/23/2016.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each
inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address
your extension request to the Building Official and state your reason(s) for the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 1/23/2016, your permit will become null and void
and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Rachelle Ripley
Y
Permit Technician
File No: EL14-124]
6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
P
RMIT NO
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project: zfrt &4„✓p
Type of Inspection:
Address: i7vDate
J5 11 S go A.-
Called:
Special Instructions:
2- P
Ali 141-3
Date Wanted:
i212-g
(m\
p.m.
Requester:
Phone No:
Approved per applicable codes. LJ Corrections required prior to approval.
coMMENTS:
Inspector: " 66iNf
Date:
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
City of Tukwila
Department of Community Development
July 9, 2015
JASON PECOTTE
12828 NORTHRUP WAY
BELLEVUE, WA 98005
RE: Application No. EL14-1241
ZAYO GROUP
3311 S 120TH PL 120TH
Dear JASON PECOTTE:
Jim Haggerton, Mayor
Jack Pace, Director
Permit application EL14-1241 for the work proposed at ZAYO GROUP (3311 S 120TH PL 120TH) has not been issued by the City
of Tukwila Permit Center. Per the International Building, Residential, and Mechanical Codes as well as the Uniform Plumbing Code
and/or the National Electric Code, every permit application not issued within 180 days from the date of application shall expire and
become null and void. Currently your application has a status of APPROVED and is due to expire 08/01/2015.
If you still plan to pursue your project, you are hereby advised to do one of the following:
1) If the plan review is completed for the project and your application is approved, you may pick up the application before
the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days.
-or-
2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the
expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your
application.
The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension
request is granted, you will be notified by mail.
In the event that your permit is not issued, we do not receive your written request for extension, or your request is denied your permit
application will expire and your project will require a new permit application, plans and specifications, and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Bill Rambo
Permit Technician
File No: EL14-1241
6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: EL14-1241
PROJECT NAME: ZAYO GROUP LLC
DATE: +A'4
SITE ADDRESS: 3311 S 120 PL
X Original Plan Submittal
Response to Correction Letter #
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
Building Division lin
Public Works
Fire Prevention
Structural
Planning Division n
Permit Coordinator
PRELIMINARY REVIEW:
Not Applicable
(no approval/review required)
DATE: 01/06/15
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
(corrections entered in Reviews)
Approved with Conditions
Denied
(ie: Zoning Issues)
DUE DATE: 02/03/15
>5'
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
TITAN ELECTRIC INC
Page 1 of 4
Home Inicio en Espanol Contact
Search L&I
SEARI
A-Z Index Help My Secure L&I
Safety Claims & Insurance Workplace Rights Trades & Licensing
Co1Nashington State Department of
Labor & Industries
TITAN ELECTRIC INC
Owner or tradesperson
Principals
BURKE, PATRICK D, PRESIDENT
CROOK, TRAVIS J, VICE PRESIDENT
FUNG, LAWRENCE H, SECRETARY
FUNG, LAWRENCE H, AGENT
Doing business as
TITAN ELECTRIC INC
WA UBI No.
602 250 925
12828 Northup Way
Suite 205
BELLEVUE, WA 98005
206-633-2811
KING County
Business type
Corporation
Governing persons
LAWRENCE
M
FUNG
PATRICK DUNIVON BURKE;
TRAVIS JAY CROOK;
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Electrical Contractor Active.
...............................................................
Meets current requirements.
License specialties
GENERAL
License no.
TITANE19630B
Effective — expiration
09/02/2004— 09/02/2016
Designated administrator
..............................
CROOK, TRAVIS
License type
Electrical Administrator
Bond
................
Lexon Ins Co
Bond account no.
9808431
Active.
Meets current requirements.
License no.
CROOKT•011 PB
$4,000.00
Received by L&I Effective date
08/08/2011 08/03/2011
Expiration date
Until Canceled
Bond history
Savings
.........................
No savings accounts during the previous 6 year period.
License Violations
........................................................
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602250925&LIC=TITANEI963OB&SAW= 07/27/2015
ols
t
■
FILE COPY
Perm it No. EL 11.1"
Plan review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted de ordinance. Receipt
of approved Field Copy a ons is acknowledged:
By:
Date:
City of Tukwila
BUILDING DIVISION
o►a
ELECTRICAL RISER
FEEDER SIZE IDENTIFICATION
AVAILABLE FAULT CURRENT IDENTIFICATION
ARRESTOR, SURGE
ARRESTOR, LIGHTNING
AUTOMATIC TRANSFER SWITCH
CONTACT, NORMALLY OPEN AND NORMALLY
CLOSED
CIRCUIT BREAKER
FUSE (ISOLATING)
FUSED SWITCH
GROUND
r m TRANSFORMER
SP
J:\1317118\CORELINKVADDO8V00 Dec 29, 2014 3:42 PM By. SHAULOV
TRANSFORMER, CURRENT
TRANSFORMER, SHIELDED, MAGNETIC CORE
SHOWN
METER
RELAY
RELAY, GFI
SURGE PROTECTIVE DEVICE
L
114
WNW ,MMID
CIRCUITS
RACEWAY CONCEALED IN CEILING OR WALL.
HASH MARKS INDICATE NUMBER OF WIRES. #12
AWG WIRE UNLESS OTHERWISE NOTED. THREE
WIRES IF NO HASH MARK SHOWN. EXPOSED
RACEWAY IS ALLOWED ONLY WHERE NOTED.
HOT (SHORT HASH MARK)
NEUTRAL (LONG HASH MARK)
GROUND WIRE (JOGGED HASH MARK)
EXISTING RACEWAY (IF HASH MARKS ARE
SHOWN, PULL NEW CONDUCTORS)
RACEWAY BELOW SLAB OR UNDERGROUND
—o RACEWAY UP
RACEWAY DOWN
RACEWAY STUB —OUT WITH BUSHING
CIRCUIT CONTINUATION
HOME RUN TO PANEL OR LOCATION NOTED
pJ El JUNCTION BOX
PB PULL BOX
41)
aitc
0
RECEPTACLES
DUPLEX RECEPTACLE 120V
DOUBLE DUPLEX RECEPTACLE 120V
RECEPTACLE 208V OR 240V, THREE PHASE
RECEPTACLE 480V, SINGLE PHASE
ap RECEPTACLE 480V, THREE PHASE
0 D
(i
0
®E
RECEPTACLE 208V OR 240V, THREE PHASE
(TWIST LOCK)
COMBINATION RECEPTACLE 120/208V OR
120/240V, SINGLE PHASE (TWIST LOCK)
RECEPTACLE TYPES
DEDICATED CIRCUIT
ISOLATED GROUND
EQUIPMENT
EQUIPMENT CABINET
EQUIPMENT CONNECTION, E = EMERGENCY
POWER
rr TT GROUND BAR, LENGTH TO SCALE
SPD
D
SURGE PROTECTIVE DEVICE
TRANSFORMER, <30KVA, NOT TO SCALE
TRANSFORMER, 30KVA OR GREATER, DRAWN TO
SCALE
WORK DEFINITION
FLAG NOTE
REVISION IDENTIFICATION
EQUIPMENT IDENTIFICATION
EQUIPMENT IDENTIFICATION
PROJECT NORTH REFERENCE
NEW WORK
EXISTING
— FUTURE
"""" REMOVE EXISTING ELECTRICAL EQUIPMENT
GENERAL NOTES
1. COMPLY WITH THE NATIONAL ELECTRICAL CODE AS ADOPTED AND AMENDED BY
THE LOCAL AUTHORITY HAVING JURISDICTION.
ABBREVIATIONS
REVISIONS Y�
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require"a new plan submittal
and may include additional plan review fees.
SE pA E PERMIT
nEQU,...,ED FOR:
ErIVIdchanical
0 Electrical
griblumbing
CiR*as Piping
C;ty of Tukwila
EU; .OP,1CG DIVISION
ABV ABOVE
AFF ABOVE FINISHED FLOOR
AG ABOVE GRADE
A,AMP AMPERE
ATS AUTOMATIC TRANSFER SWITCH
AWG AMERICAN WIRE GAUGE
CB CIRCUIT BREAKER
CKT CIRCUIT
CLG CEILING
COMM COMMUNICATIONS
C CONDUIT
CO CONDUIT ONLY
CTRL CONTROL
CU COPPER
D DATA
DED DEDICATED
DEV DEVICE
DN DOWN
FBOIC FURNISHED BY OTHERS, INSTALLED BY
CONTRACTOR
G,GND GROUND
HH HAND HOLE
J—BOX JUNCTION BOX
MDF MAIN DISTRIBUTION FRAME/FACILITY
MM MULTIMODE
MTD MOUNTED
MW
N
NIC
OPOI
PB
PNL
PR
R
RO
RECEPT
SLV
SPECS
SW
SWBD
MICROWAVE
NEUTRAL
NOT IN CONTRACT
OWNER PROVIDED OWNER INSTALLED
PULLBOX
PANEL, PANELBOARD
PAIR
RACEWAY
RACEWAY ONLY
RECEPTACLE
SLEEVE
SPECIFICATIONS
SWITCH
SWITCHBOARD
TELECOM TELECOMMUNICATIONS
TYP TYPICAL
OF UNDER FLOOR
UG
UON
V
VEL
W
WP
XFMR
0
UNDER GROUND
UNLESS OTHERWISE NOTED
VOLT OR VOICE
VERIFY EXACT LOCATION
WIRE, WATT, OR WALLPHONE
WEATHERPROOF
TRANSFORMER
PHASE
REVIEWED .FOR
COMPLIANCE WITH
NPPA 70 d NEC
JAN 0 9 2015
‘.1?› WAL
City of Tukwila,
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
DEC 3 1 2014
PERMIT CENTER
E1,114--12-M1
Cif)
WORK TOGETHER I STAND APARTTM'
u7
O
(75
w.
Z
0
co
oC
w
0
a
SHEET:
E0.0
JAB17118VORELINKVADDO8V10 Dec 29, 2014 3:42 PM BySHALILOV
3 +
3' 3
3 • t'
, • . .
VeI
'„ 'i:73 .3,, •.3
ij44
•
e
i
7:44
3 ,3
• 3 3
I
'3
• I •
' 4 ••
• ; -
;
•; 33,
4444
41
44
1
33
44
t
3 3
14
• ...3337';',331'33:33""3,77333,3;33:737,f7'.33,3....33-1.3..-3,37;73,33377.337.7733-3:1..73-333.3'3.7::
41
77
4444
3.
t • 3
f 3
3 : l• 't i." ';
'
I „3
, ! „ ;,. A ,.
• • • .
••
313
.3
;
9
1,3
; )
•
PDU-16
.3,
9
PDU-17
PANEL 'PDU-16Ci'
PANEL 'PDU-16D1
„
14
3 9 .
3 3
‘—• ‘—•
•,3"
44
• '3
7
.11
.3
ELECTRICAL POWER PLAN
SCALE: AS INDICATED
C:1
0
D
C =It
Cl_
0
czi
P
_J _J
L.L.1 ▪ UJJ L.LJ
< < < <
a_
< 0 4 8 24
1 inch plotted
If measurement is other than
1 inch then the [At is reduced.
Feet
FEED FROM EXISTING PDU-16
FEED FROM EXISTING PDU-17
V-ir
f.4; VC
" • . • • ' ' •
3 3
4'', ; t.3•3.
•3
;
' •
17
7-1
.47
Irr
Ira we
,
?, .1_1,0
4 „
, ,3 •
....
, .
. , •. ,
3 .
;., t I
1-
r-V
41
7
1'4 VS.
f-f
331
44
• ,
r-r
iv 10
7
.f•-• 10
77 ?'‘
't •
I
1 . . .
...
i '
' • , •
1 ! ,
4474
I , ;
3 •; 3
# ,
„ 9
t 3
REVIEWED hi,..4-,
COMPLIANCE Wr,
NFPA 70 - NEC
JAN 0 9 2015
City of Tukwila
BUILDING DIVISION_
Eii
RECEIVED
CITY OF TUKWILA
C 3 1 201
IN
z
Omuffirx*
cc
Lon
z
0
LU
0
0
—J
0
Li!
z
(i)
z
< 0
F-
< (/)
0 >
11-1
z
LLI U-I
Le 0 0
z a.
0
EE T:
E1.0
16
J: \B17118\CORELINK\CADD08\E20 Dec 29, 2014 3:42 PM By. SHAULOV
00
oo
CD
N N J
( 1-0 (� �w (CD EL b (8 co
CO N (/) 00 V) J O
-J 00 J
J
BATT
"Cl-BATT3" BAIT
"C1-BATT2" BATT
1,,C1-BATT1"
600A
i-N
0
600A
0 0
600A
0 0
U
co
za
800G
( Z Q (b
o¢_ O¢-
� (�)J �(1)J
UPS-C1
CONVRTR
(2)2"C-#300 THHN -
TAP BOX
DP1 2000A DIST. PANEL
480/277V, 3PH, 4W, 65K AIC
1200G
a
CO
N O
300kVA
PDU-16
< 30,945A
250A/3P
1-1/4"C, 34, 110G-
PANEL
'PDU-16C'
250A/3P
--r-a-
250A/3P
PROVIDE NEW BREAKER -
INVR.
V)
za
CL
800G
m
0 O
0
ao
CC)
8P-C1 1200A PANEL
480V, 3PH-3W, 65K AIC
UPS DISTRIBUTION C1 PANEL "DIST-C1"
1200A, 480V, 3PH-3W, 65K AIC
60A 3P
60A 3P -�
PANEL
'PDU-16D'
6D1A 3P
60 3P
6DA 3P
PANEL
'PDU-16F',
10,559A> 40A 3P
40A 3P
40 3P
-2-1/2'C, 4-250kcrnd, 414G
00
CD CD CD
O O Cg J
0
\
Q
COJ
0
Cl_
800G
SHB 3000A SWITCHBOARD
480/277V, 3PH, 4W, 65K AIC
QQ
c:D CD OOCD(o
00(n
N N J
(CO o (o
CODE SIZE
SPLICE BOX
( 450C3
MECH
( CH >
SCL TRANSFORMER
4160/2400V DELTA
SECONDARY
01
MVA-MAIN
450AT
2000AF
02
TXMV1A
450AT (
2000AF ,T,.
Y
b
T
03
TXMV1B
450AT
2000AF
<E-°�z,_)
04
05
«-O--4,4>
GENERAT 0
BREAKER
1200AF CT 7
GEN-BKR-1 I
GENERATOR Z
BREAKER
1200AF
GEN-BKR-2 .,
MV1 4160/2400V MAIN SWITCHGEAR 2000A
SWITCHBOARD SHA
3000A, 480/277V, 3PH, 4W, 65K AIC
N
S
UPS-D1
CONVRTR
100C3
100C3
( 100C3
( 100C3
100C3
2000AF
2000AT
LSG 1 1
O O O
"NO" (O O ( O
o
BATT
BATT "D1-BATT3"
BAIT "D 1- BATT2" 1
"D1-BATT1"
600A
0
600A
0 0
600A
- (2)2"C-#300 THHN
INVR.
800G
J
BP-D1 1200A PANEL
480V, 3PH-3W, 65K AIC
- 1-1/4"C, 344, #10G
PANEL
'PDU-17C'
6OMP
60A 3P
60 P
N
10
TAP BOX
0
( 1200G
•
1200A/3P
MECH
( 600C4
UPS DISTRIBUTION Cl PANEL "DIST-D1"
1200A, 480V, 3PH-3W, 65K AIC
00
00 U)(
CO < J
I-w b -,,w
(O 8 Lc (O (O
(O N ",1-(n V CO< a
300kVA
29,977A
PDU-17
250A/3P
PANEL
'POU-17D'
PANEL
'PDU-17E'
40A 3P
4OA 3P
44A 3P
<10,457A
250A/3P
250A/3P
2-1/2'C, 4-250kcmi, I4G -
\--PROVIDE NEW BREAKER
1200G
MCC-1, 600A 480/277V
0
o<
oa
<V)
'wI�wl�wl
o¢( 0¢( oa(
Oa_ 0 on_ 0 oa °
a (n -r v)
MECH
( :000C4
<
(O < (O < (O J
MECH
4-->
4-->
1
( 600C4
ATS-IB-MCC-A
600A 480V,
3PH-4W, 4-POLE
42k AIC
CODE SIZE
SPLICE BOX
ATS CRA-1 THRU 5
100A MANUAL
TRANSFER SWITCH
65K AIC, TYP
600C4
PANEL
LB
TXG-2
75kVA TRANSFORMER
480V PRIMARY
208/120V SECONDARY
ELECTRICAL POWER RISER DIAGRAM
SCALE:NONE
C600NG
PANEL
HA
2 MW
- 4160V
GENERATOR A
2 MW
4160V
GENERATOR A
TXMV1B
TXG-1
75kVA TRANSFORMER
480V PRIMARY
208/120V SECONDARY
T
PANEL
LA
75kVA
75kVA
75kVA
75kVA
75kVA
75kVA
75kVA
75kVA
D zm
_ 5 ( '2
0
Q Q ° J O o
D -oo
BATT
"A1-BATT3" BATT
r
"A1-BATT2" BAIT
"A1-BATT1"
600A
0
( 800C3
600A
°
600A
( 800C3
NEW 500kW
UPS -Al
CONVRTR
(2)2"C-#300 THHN -
3
INVR.
E6.01
S
( 800C3
0
moCD -
(1) CO
0
w
52L NC" O CL
V)
-0
0
(° D�
800A/3P
LSI
a_
(0
Q [)
BP -Al 800A PANEL
480V, 3PH-3W, 65K AIC
1200A
480V, 3PH
PDU 4
C800C3
PANEL
U1DP2
1200A/3P
MAIN
0
100A/3P
100A/3P
°
100A/3P
O
125A/3P
00
100A/3P
PDU-14
PDU 7
PDU 9
PDU 11
0
125A/3P
iN
0 0
125A/3P
PDU 13
o °
125A/3P
100A/3P
0
SPARE
100A/3P
SPARE
100A/3P
0 0
SPARE
ATS-MV-B
600A
4160, 3PH-3W,
40K AIC, 3-POLE
4160V
480/2775EC
2500 kVA
47 NEMA 3R
O
m \ (U O O
O 3 Q2-
(n 0
azoco
( 800C3
0 E2
U
(n N
5
NEW 500kW
UPS-B1
CONVRTR
TXMV1A
ATS-MV-A
600A
4160, 3PH-3W,
40K AIC, 3-POLE
�4160V
480/277SEC
2500 kVA
0
3000A
BAIT
BATT "B 1-BATT3"
BAIT "B 1-BATT2"
"B1-BATT1"
600A
0 0
600A
0 0
600A
INVR.
- (2)2"C-#300 THHN
3
E6.01
0
( 800C3
a o_
O
0 (o N (
BP-B1 800A PANEL
480V, 3PH-3W, 65K AIC u.)
"NC" 52L
O O •
800A/3P
LSI
800C3
PANEL
U1DP1
1200A/3P
MAIN
0 0
100A/3P
100A/3P
100A/3P
O o
125A/3P
125A/3P
0
125A/3P
125A/3P
0 0
100A/3P
0 0
SPARE
100A/3P
SPARE
100A/3P
0 0
SPARE
100A/3P
0
SPARE
1200A
480V, 3PH
PDU-1
PDU-5
PDU-6
75kVA
75kVA
75kVA
PDU-15 75kVA
PDU-8 75kVA
PDU-10 75kVA
PDU-12 75kVA
REVIEWED FOR
COMPLIANCE WITH
NFPA 70 - NEC
JAN 0 9 2015
City of Tukwila -
BUILDING DIVISION
RECEIVED
1TY OF T KWILA
DEC 3
urtIV11T
0
w
z
W
z
-J
Fe
w<
w 0
It
LW
z
W (i)
U z
<O
Q Cn
0
W
z
W W
zoo
o 0 Q-
SHEET: