Loading...
HomeMy WebLinkAboutPermit EL14-1241 - ZAYO GROUP - PANELS, ATS AND POWER FOR DOORSZAYO GROUP 3311 S 12OT'PL EL14-1241 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov ELECTRICAL PERMIT 1023049078 Permit Number: 3311 S 120TH PL 120TH Project Name: ZAYO GROUP Issue Date: Permit Expires On: EL14-1241 7/27/2015 1/23/2016 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: SABEY CORPORATION 4TH FLOOR 12201 TUKWILA INTL BLVD, SEATTLE, WA, 98168 JASON PECOTTE 12828 NORTHRUP WY, BELLEVUE, WA, 98005 TITAN ELECTRIC INC 12828 NORTHUP WAY SUITE 205, BELLEVUE, WA, 98005 TITANEI963OB 11/ Phone: (206) 551-7195 Phone: (206) 633-2811 Expiration Date: 9/2/2016 DESCRIPTION OF WORK: ADD (2) 225 AMP PANELS, RECOMMISSION ATS A & B AND INSTALL LOW VOLTAGE POWER FOR DOORS Valuation of single family: $0.00 Valuation of mf/comm: $18,000.00 Type of Work: TENANT IMP Fees Collected: $537.42 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125,TUKWILA Sewer District: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Permit Center Authorized Signature: -�W`-'r.aAl Date: -7- -7-1 `� I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating cstru • r the performance of work. I am authorized to sign and obtain this development permit and a to . ditions attached to this permit. Signature: Date: Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKif 1 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. Project No. Date Application Accepted: Date Application Expires: 1�. 31- (1-f (For office use only) 30 1 ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 3311 S. 120th Pl. Suite Number: 120 Floor: Tenant Name: Zayo Group LLC PROPERTY OWNER Name: Zayo Group LLC Address: 3311 S. 120th Pl. Suite 120 City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Jason Pecotte Address: 12828 Northup Way Suite 205 City: Bellevue State: WA Zip: 98005 Phone: (206) 551-7195 Fax: (206) 374-2128 Email: Jasonp@titanelectric.net Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Job 149241: Recommission ATS A&B and install low voltage power for doors New Tenant: ❑ Yes .. No ELECTRICAL CONTRACTOR INFORMATION Company Name: Titan Electric Address: 12828 Northup Way Suite 205 City: Bellevue State: WA Zip: 98005 Phone: (206) 633-2811 Fax: (206) 374-2128 Contr Reg No.: 602-250-925 Exp Date: 12/31/2014 Tukwila Business License No.: Bus-0992893 Ackd (2) ZzsA Will service be altered? ❑ Yes Type of Use: Commercial PcsavNeAS ❑✓ No Adding more than 50 amps? Type of work: ❑ New ❑ Addition ❑ Service Change E Low Voltage ❑ Generator ❑ Fire Alarm Property Served by: O Puget Sound Energy ❑ Seattle City Light H:.ApplicationsForms-Applications On Line201 I Applications.:Electrical Permit Application Revised 8-9-I I.docx Revised: August 2011 bh ❑ Remodel ❑ Telecommunication X Yes No O Tenant Improvement ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature�� Date: 12/10/2014 Print Name: Titan Electric/Kristie Dougherty Day Telephone: (425) 250-3595 Mailing Address: 12828 Northup Way Suite 205 Bellevue WA 98103 City State Zip H:\Applications\Forms-Applications On Line\2011 Applications'Electrical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT PermitTRAK QUANTITY PAID $537.42 EL14-1241 Address: 3311 S 120TH PL 120TH Apn: 1023049078 $537.42 ELECTRICAL $516.75 PLAN CHECK FEE R000.345.832.00.00 0.00 $103.35 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $413.40 TECHNOLOGY FEE $20.67 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R3890 R000.322.900.04.00 0.00 $20.67 $537.42 Date Paid: Wednesday, December 31, 2014 Paid By: TITAN ELECTRIC INC Pay Method: CHECK 17964 Printed: Wednesday, December 31, 2014 1:37 PM 1 of 1 SYSTEMS City of Tukwila Department of Community Development 12/1/2015 JASON PECOTTE 12828 NORTHRUP WY BELLEVUE, WA 98005 RE: Permit No. EL14-1241 ZAYO GROUP 3311 S 120 PL STE 120 Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 1/23/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 1/23/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Rachelle Ripley Y Permit Technician File No: EL14-124] 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 INSPECTION NO. INSPECTION RECORD Retain a copy with permit P RMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: zfrt &4„✓p Type of Inspection: Address: i7vDate J5 11 S go A.- Called: Special Instructions: 2- P Ali 141-3 Date Wanted: i212-g (m\ p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. coMMENTS: Inspector: " 66iNf Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. City of Tukwila Department of Community Development July 9, 2015 JASON PECOTTE 12828 NORTHRUP WAY BELLEVUE, WA 98005 RE: Application No. EL14-1241 ZAYO GROUP 3311 S 120TH PL 120TH Dear JASON PECOTTE: Jim Haggerton, Mayor Jack Pace, Director Permit application EL14-1241 for the work proposed at ZAYO GROUP (3311 S 120TH PL 120TH) has not been issued by the City of Tukwila Permit Center. Per the International Building, Residential, and Mechanical Codes as well as the Uniform Plumbing Code and/or the National Electric Code, every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire 08/01/2015. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is completed for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that your permit is not issued, we do not receive your written request for extension, or your request is denied your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: EL14-1241 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL14-1241 PROJECT NAME: ZAYO GROUP LLC DATE: +A'4 SITE ADDRESS: 3311 S 120 PL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division lin Public Works Fire Prevention Structural Planning Division n Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 01/06/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 02/03/15 >5' Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 TITAN ELECTRIC INC Page 1 of 4 Home Inicio en Espanol Contact Search L&I SEARI A-Z Index Help My Secure L&I Safety Claims & Insurance Workplace Rights Trades & Licensing Co1Nashington State Department of Labor & Industries TITAN ELECTRIC INC Owner or tradesperson Principals BURKE, PATRICK D, PRESIDENT CROOK, TRAVIS J, VICE PRESIDENT FUNG, LAWRENCE H, SECRETARY FUNG, LAWRENCE H, AGENT Doing business as TITAN ELECTRIC INC WA UBI No. 602 250 925 12828 Northup Way Suite 205 BELLEVUE, WA 98005 206-633-2811 KING County Business type Corporation Governing persons LAWRENCE M FUNG PATRICK DUNIVON BURKE; TRAVIS JAY CROOK; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. ............................................................... Meets current requirements. License specialties GENERAL License no. TITANE19630B Effective — expiration 09/02/2004— 09/02/2016 Designated administrator .............................. CROOK, TRAVIS License type Electrical Administrator Bond ................ Lexon Ins Co Bond account no. 9808431 Active. Meets current requirements. License no. CROOKT•011 PB $4,000.00 Received by L&I Effective date 08/08/2011 08/03/2011 Expiration date Until Canceled Bond history Savings ......................... No savings accounts during the previous 6 year period. License Violations ........................................................ https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602250925&LIC=TITANEI963OB&SAW= 07/27/2015 ols t ■ FILE COPY Perm it No. EL 11.1" Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted de ordinance. Receipt of approved Field Copy a ons is acknowledged: By: Date: City of Tukwila BUILDING DIVISION o►a ELECTRICAL RISER FEEDER SIZE IDENTIFICATION AVAILABLE FAULT CURRENT IDENTIFICATION ARRESTOR, SURGE ARRESTOR, LIGHTNING AUTOMATIC TRANSFER SWITCH CONTACT, NORMALLY OPEN AND NORMALLY CLOSED CIRCUIT BREAKER FUSE (ISOLATING) FUSED SWITCH GROUND r m TRANSFORMER SP J:\1317118\CORELINKVADDO8V00 Dec 29, 2014 3:42 PM By. SHAULOV TRANSFORMER, CURRENT TRANSFORMER, SHIELDED, MAGNETIC CORE SHOWN METER RELAY RELAY, GFI SURGE PROTECTIVE DEVICE L 114 WNW ,MMID CIRCUITS RACEWAY CONCEALED IN CEILING OR WALL. HASH MARKS INDICATE NUMBER OF WIRES. #12 AWG WIRE UNLESS OTHERWISE NOTED. THREE WIRES IF NO HASH MARK SHOWN. EXPOSED RACEWAY IS ALLOWED ONLY WHERE NOTED. HOT (SHORT HASH MARK) NEUTRAL (LONG HASH MARK) GROUND WIRE (JOGGED HASH MARK) EXISTING RACEWAY (IF HASH MARKS ARE SHOWN, PULL NEW CONDUCTORS) RACEWAY BELOW SLAB OR UNDERGROUND —o RACEWAY UP RACEWAY DOWN RACEWAY STUB —OUT WITH BUSHING CIRCUIT CONTINUATION HOME RUN TO PANEL OR LOCATION NOTED pJ El JUNCTION BOX PB PULL BOX 41) aitc 0 RECEPTACLES DUPLEX RECEPTACLE 120V DOUBLE DUPLEX RECEPTACLE 120V RECEPTACLE 208V OR 240V, THREE PHASE RECEPTACLE 480V, SINGLE PHASE ap RECEPTACLE 480V, THREE PHASE 0 D (i 0 ®E RECEPTACLE 208V OR 240V, THREE PHASE (TWIST LOCK) COMBINATION RECEPTACLE 120/208V OR 120/240V, SINGLE PHASE (TWIST LOCK) RECEPTACLE TYPES DEDICATED CIRCUIT ISOLATED GROUND EQUIPMENT EQUIPMENT CABINET EQUIPMENT CONNECTION, E = EMERGENCY POWER rr TT GROUND BAR, LENGTH TO SCALE SPD D SURGE PROTECTIVE DEVICE TRANSFORMER, <30KVA, NOT TO SCALE TRANSFORMER, 30KVA OR GREATER, DRAWN TO SCALE WORK DEFINITION FLAG NOTE REVISION IDENTIFICATION EQUIPMENT IDENTIFICATION EQUIPMENT IDENTIFICATION PROJECT NORTH REFERENCE NEW WORK EXISTING — FUTURE """" REMOVE EXISTING ELECTRICAL EQUIPMENT GENERAL NOTES 1. COMPLY WITH THE NATIONAL ELECTRICAL CODE AS ADOPTED AND AMENDED BY THE LOCAL AUTHORITY HAVING JURISDICTION. ABBREVIATIONS REVISIONS Y� No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require"a new plan submittal and may include additional plan review fees. SE pA E PERMIT nEQU,...,ED FOR: ErIVIdchanical 0 Electrical griblumbing CiR*as Piping C;ty of Tukwila EU; .OP,1CG DIVISION ABV ABOVE AFF ABOVE FINISHED FLOOR AG ABOVE GRADE A,AMP AMPERE ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE CB CIRCUIT BREAKER CKT CIRCUIT CLG CEILING COMM COMMUNICATIONS C CONDUIT CO CONDUIT ONLY CTRL CONTROL CU COPPER D DATA DED DEDICATED DEV DEVICE DN DOWN FBOIC FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR G,GND GROUND HH HAND HOLE J—BOX JUNCTION BOX MDF MAIN DISTRIBUTION FRAME/FACILITY MM MULTIMODE MTD MOUNTED MW N NIC OPOI PB PNL PR R RO RECEPT SLV SPECS SW SWBD MICROWAVE NEUTRAL NOT IN CONTRACT OWNER PROVIDED OWNER INSTALLED PULLBOX PANEL, PANELBOARD PAIR RACEWAY RACEWAY ONLY RECEPTACLE SLEEVE SPECIFICATIONS SWITCH SWITCHBOARD TELECOM TELECOMMUNICATIONS TYP TYPICAL OF UNDER FLOOR UG UON V VEL W WP XFMR 0 UNDER GROUND UNLESS OTHERWISE NOTED VOLT OR VOICE VERIFY EXACT LOCATION WIRE, WATT, OR WALLPHONE WEATHERPROOF TRANSFORMER PHASE REVIEWED .FOR COMPLIANCE WITH NPPA 70 d NEC JAN 0 9 2015 ‘.1?› WAL City of Tukwila, BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 3 1 2014 PERMIT CENTER E1,114--12-M1 Cif) WORK TOGETHER I STAND APARTTM' u7 O (75 w. Z 0 co oC w 0 a SHEET: E0.0 JAB17118VORELINKVADDO8V10 Dec 29, 2014 3:42 PM BySHALILOV 3 + 3' 3 3 • t' , • . . VeI '„ 'i:73 .3,, •.3 ij44 • e i 7:44 3 ,3 • 3 3 I '3 • I • ' 4 •• • ; - ; •; 33, 4444 41 44 1 33 44 t 3 3 14 • ...3337';',331'33:33""3,77333,3;33:737,f7'.33,3....33-1.3..-3,37;73,33377.337.7733-3:1..73-333.3'3.7:: 41 77 4444 3. t • 3 f 3 3 : l• 't i." '; ' I „3 , ! „ ;,. A ,. • • • . •• 313 .3 ; 9 1,3 ; ) • PDU-16 .3, 9 PDU-17 PANEL 'PDU-16Ci' PANEL 'PDU-16D1 „ 14 3 9 . 3 3 ‘—• ‘—• •,3" 44 • '3 7 .11 .3 ELECTRICAL POWER PLAN SCALE: AS INDICATED C:1 0 D C =It Cl_ 0 czi P _J _J L.L.1 ▪ UJJ L.LJ < < < < a_ < 0 4 8 24 1 inch plotted If measurement is other than 1 inch then the [At is reduced. Feet FEED FROM EXISTING PDU-16 FEED FROM EXISTING PDU-17 V-ir f.4; VC " • . • • ' ' • 3 3 4'', ; t.3•3. •3 ; ' • 17 7-1 .47 Irr Ira we , ?, .1_1,0 4 „ , ,3 • .... , . . , •. , 3 . ;., t I 1- r-V 41 7 1'4 VS. f-f 331 44 • , r-r iv 10 7 .f•-• 10 77 ?'‘ 't • I 1 . . . ... i ' ' • , • 1 ! , 4474 I , ; 3 •; 3 # , „ 9 t 3 REVIEWED hi,..4-, COMPLIANCE Wr, NFPA 70 - NEC JAN 0 9 2015 City of Tukwila BUILDING DIVISION_ Eii RECEIVED CITY OF TUKWILA C 3 1 201 IN z Omuffirx* cc Lon z 0 LU 0 0 —J 0 Li! z (i) z < 0 F- < (/) 0 > 11-1 z LLI U-I Le 0 0 z a. 0 EE T: E1.0 16 J: \B17118\CORELINK\CADD08\E20 Dec 29, 2014 3:42 PM By. SHAULOV 00 oo CD N N J ( 1-0 (� �w (CD EL b (8 co CO N (/) 00 V) J O -J 00 J J BATT "Cl-BATT3" BAIT "C1-BATT2" BATT 1,,C1-BATT1" 600A i-N 0 600A 0 0 600A 0 0 U co za 800G ( Z Q (b o¢_ O¢- � (�)J �(1)J UPS-C1 CONVRTR (2)2"C-#300 THHN - TAP BOX DP1 2000A DIST. PANEL 480/277V, 3PH, 4W, 65K AIC 1200G a CO N O 300kVA PDU-16 < 30,945A 250A/3P 1-1/4"C, 34, 110G- PANEL 'PDU-16C' 250A/3P --r-a- 250A/3P PROVIDE NEW BREAKER - INVR. V) za CL 800G m 0 O 0 ao CC) 8P-C1 1200A PANEL 480V, 3PH-3W, 65K AIC UPS DISTRIBUTION C1 PANEL "DIST-C1" 1200A, 480V, 3PH-3W, 65K AIC 60A 3P 60A 3P -� PANEL 'PDU-16D' 6D1A 3P 60 3P 6DA 3P PANEL 'PDU-16F', 10,559A> 40A 3P 40A 3P 40 3P -2-1/2'C, 4-250kcrnd, 414G 00 CD CD CD O O Cg J 0 \ Q COJ 0 Cl_ 800G SHB 3000A SWITCHBOARD 480/277V, 3PH, 4W, 65K AIC QQ c:D CD OOCD(o 00(n N N J (CO o (o CODE SIZE SPLICE BOX ( 450C3 MECH ( CH > SCL TRANSFORMER 4160/2400V DELTA SECONDARY 01 MVA-MAIN 450AT 2000AF 02 TXMV1A 450AT ( 2000AF ,T,. Y b T 03 TXMV1B 450AT 2000AF <E-°�z,_) 04 05 «-O--4,4> GENERAT 0 BREAKER 1200AF CT 7 GEN-BKR-1 I GENERATOR Z BREAKER 1200AF GEN-BKR-2 ., MV1 4160/2400V MAIN SWITCHGEAR 2000A SWITCHBOARD SHA 3000A, 480/277V, 3PH, 4W, 65K AIC N S UPS-D1 CONVRTR 100C3 100C3 ( 100C3 ( 100C3 100C3 2000AF 2000AT LSG 1 1 O O O "NO" (O O ( O o BATT BATT "D1-BATT3" BAIT "D 1- BATT2" 1 "D1-BATT1" 600A 0 600A 0 0 600A - (2)2"C-#300 THHN INVR. 800G J BP-D1 1200A PANEL 480V, 3PH-3W, 65K AIC - 1-1/4"C, 344, #10G PANEL 'PDU-17C' 6OMP 60A 3P 60 P N 10 TAP BOX 0 ( 1200G • 1200A/3P MECH ( 600C4 UPS DISTRIBUTION Cl PANEL "DIST-D1" 1200A, 480V, 3PH-3W, 65K AIC 00 00 U)( CO < J I-w b -,,w (O 8 Lc (O (O (O N ",1-(n V CO< a 300kVA 29,977A PDU-17 250A/3P PANEL 'POU-17D' PANEL 'PDU-17E' 40A 3P 4OA 3P 44A 3P <10,457A 250A/3P 250A/3P 2-1/2'C, 4-250kcmi, I4G - \--PROVIDE NEW BREAKER 1200G MCC-1, 600A 480/277V 0 o< oa <V) 'wI�wl�wl o¢( 0¢( oa( Oa_ 0 on_ 0 oa ° a (n -r v) MECH ( :000C4 < (O < (O < (O J MECH 4--> 4--> 1 ( 600C4 ATS-IB-MCC-A 600A 480V, 3PH-4W, 4-POLE 42k AIC CODE SIZE SPLICE BOX ATS CRA-1 THRU 5 100A MANUAL TRANSFER SWITCH 65K AIC, TYP 600C4 PANEL LB TXG-2 75kVA TRANSFORMER 480V PRIMARY 208/120V SECONDARY ELECTRICAL POWER RISER DIAGRAM SCALE:NONE C600NG PANEL HA 2 MW - 4160V GENERATOR A 2 MW 4160V GENERATOR A TXMV1B TXG-1 75kVA TRANSFORMER 480V PRIMARY 208/120V SECONDARY T PANEL LA 75kVA 75kVA 75kVA 75kVA 75kVA 75kVA 75kVA 75kVA D zm _ 5 ( '2 0 Q Q ° J O o D -oo BATT "A1-BATT3" BATT r "A1-BATT2" BAIT "A1-BATT1" 600A 0 ( 800C3 600A ° 600A ( 800C3 NEW 500kW UPS -Al CONVRTR (2)2"C-#300 THHN - 3 INVR. E6.01 S ( 800C3 0 moCD - (1) CO 0 w 52L NC" O CL V) -0 0 (° D� 800A/3P LSI a_ (0 Q [) BP -Al 800A PANEL 480V, 3PH-3W, 65K AIC 1200A 480V, 3PH PDU 4 C800C3 PANEL U1DP2 1200A/3P MAIN 0 100A/3P 100A/3P ° 100A/3P O 125A/3P 00 100A/3P PDU-14 PDU 7 PDU 9 PDU 11 0 125A/3P iN 0 0 125A/3P PDU 13 o ° 125A/3P 100A/3P 0 SPARE 100A/3P SPARE 100A/3P 0 0 SPARE ATS-MV-B 600A 4160, 3PH-3W, 40K AIC, 3-POLE 4160V 480/2775EC 2500 kVA 47 NEMA 3R O m \ (U O O O 3 Q2- (n 0 azoco ( 800C3 0 E2 U (n N 5 NEW 500kW UPS-B1 CONVRTR TXMV1A ATS-MV-A 600A 4160, 3PH-3W, 40K AIC, 3-POLE �4160V 480/277SEC 2500 kVA 0 3000A BAIT BATT "B 1-BATT3" BAIT "B 1-BATT2" "B1-BATT1" 600A 0 0 600A 0 0 600A INVR. - (2)2"C-#300 THHN 3 E6.01 0 ( 800C3 a o_ O 0 (o N ( BP-B1 800A PANEL 480V, 3PH-3W, 65K AIC u.) "NC" 52L O O • 800A/3P LSI 800C3 PANEL U1DP1 1200A/3P MAIN 0 0 100A/3P 100A/3P 100A/3P O o 125A/3P 125A/3P 0 125A/3P 125A/3P 0 0 100A/3P 0 0 SPARE 100A/3P SPARE 100A/3P 0 0 SPARE 100A/3P 0 SPARE 1200A 480V, 3PH PDU-1 PDU-5 PDU-6 75kVA 75kVA 75kVA PDU-15 75kVA PDU-8 75kVA PDU-10 75kVA PDU-12 75kVA REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JAN 0 9 2015 City of Tukwila - BUILDING DIVISION RECEIVED 1TY OF T KWILA DEC 3 urtIV11T 0 w z W z -J Fe w< w 0 It LW z W (i) U z <O Q Cn 0 W z W W zoo o 0 Q- SHEET: E2.0