HomeMy WebLinkAboutPermit M14-0012 - QUICKSALL RESIDENCE - RENOVATION FOR RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTQUICKSALL RESIDENCE
11870 44 PL S
M14-0012
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
.MECHANICAL PERMIT
Parcel No: 3347400790 Permit Number: M14-0012
Address: 11870 44 PL S Issue Date: 5/19/2014
Permit Expires On: 11/15/2014
Project Name: QUICKSALL RESIDENCE
Owner:
Name: QUICKSALL LARRY E
Address: 11870 44TH PL S , TUKWILA, WA,
98178
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE, WA,
98108
Contractor:
Name: G & G SPECIALTY CONTRCTORS INC
Address: 4633 S 36 ST , PHOENIX, AZ, 85040
License No: GGSPEGS919RT
Lender:
Name:
Address:
/ / 1
Phone: (206) 296-7437
Phone: (480) 921-4079
Expiration Date: 12/31/2015
DESCRIPTION OF WORK:
MECHANICAL RENOVATION OF SINGLE FAMILY HOME REQUIRE FOR PARTICIPATION IN FAA (RANRIP)
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM TO REDUCE NOISE FILTRATION. THIS WORK
MAY INCLUDE STAND ALONG BLENDING UNIT VENTILATION SYSTEM WITH ASSOCIATED DUCTING AND/OR
VOLUME DAMPER INSTALLATION TO EXISTING FURNACE WITH EXISTING DUCTING
Valuation of Work: $1,554.00
Type of Work:
Fuel type:
Fees Collected: $221.32
Electrical Service Provided by: SEATTLE CITY LIGHT
Water District: TUKWILA
Sewer Distric: TUKWILA SEWER SERVICE
Current Codes adopted by the City of Tukwila:
Internations Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
2012 International Fuel Gas Code:
2012 WA Cities Electrical Code:
2012 WA State Energy Code:
2012
2012
2012
2012
Permit Center Authorized Signature:
Date:
Ic�,l��1
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature: `
Print Name: X/,e/
MAL/,,. M4/4/L
Date: '/c7- j7
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or
if the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***BUILDING PERMIT CONDITIONS***
2: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
3: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector
based on satisfactory completion of this requirement.
5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the
City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or
other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
8: ***MECHANICAL PERMIT CONDITIONS***
9: All mechanical work shall be inspected and approved under a separate permit issued by the City of
Tukwila Permit Center (206/431-3670).
10: Manufacturers installation instructions shall be available on the job site at the time of inspection.
11: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired
appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces:
Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1800 MECHANICAL FINAL
0701 ROUGH -IN MECHANICAL
Tenant Name:
•
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Mechanical Permit No. MVA V 0
Project No.
Date Application Accepted:
Date Application Expires:
Ol- tv-1q
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION
King Co Assessor's Tax No.: 3347400790
Site Address: 11870 44th Pl. S. Suite Number: Floor:
New Tenant: ❑ Yes 0 ..No
PROPERTY OWNER
Name:
CJ
0tAlrh1`f'v
VV�L `�
Address:
City:
State:
Zip:
CONTACT PERSON — person receiving all project
communication
Name: Sharyn Parker
Address: 7277 Perimeter Road South
City: Seattle State: WA Zip: 98106
Phone: (206) 296-7437 Fax: (206) 269-7315
Email: Sharyn.Parker@kingcounty.gov
MECHANICAL CONTRACTOR INFORMATION
Company Name: not yet awarded
Address:
City: State:
Zip:
Phone: Fax:
Contr Reg No.:
Exp Date:
Tukwila Business License No.:
Valuation of project (contractor's bid price): $ 1,554
Describe the scope of work in detail:
Mechanical renovation of single-family home required for participation in FAA (RANRIP) Residential Aircraft Noise Remedy
Improvements Program to reduce noise infiltration. This work may include: stand-alone blending unit ventilation system with
associated ducting and / or volume damper installation to existing furnace with existing ducting.
Use: Residential: New ❑ Replacement ❑
Commercial: New ❑ Replacement ❑
Fuel Type: Electric ❑
Gas ❑
Other:
H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx
Revised: August 2011
bh
Page 1 of 2
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Furnace >100k btu
Floor furnace
Suspended/wall/floor
mounted heater
Appliance vent
Repair or addition to
heat/refrig/cooling
system
Air handling unit
<10,000 cfm
Unit Type
Qty
Air handling unit
>10,000 cfm
Evaporator cooler
Ventilation fan
connected to single duct
Ventilation system
1
Hood and duct
Incinerator — domestic
Incinerator —
comm/industrial
Unit Type
Qty
Fire damper
Diffuser
Thermostat
Wood/gas stove
Emergency generator
Other mechanical
equipment
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER 4
Signature:
THORIZED AGENT:
Date: t e,cx'& % [(1
Print Name: imothy Fen . son Day Telephone: (206) 624-2777
Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106
City State Zip
H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx
Revised: August 2011
bh
Page 2 of 2
DESCRIPTIONS
PermitTRAK
ACCOUNT QUANTITY PAID
$30,413.70
D14-0006 Address: 4928 S 113 ST
Apn: 3348401741 $1,337.30
DEVELOPMENT
$1,298.10
PERMIT FEE
R000.322.100.00.00
$784.00
PLAN CHECK FEE
R000.345.830.00.00
$509.60
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$39.20
TECHNOLOGY FEE
R000.322.900.04.00
$39.20
D14-0007 Address: 4230 S 116 ST
Apn: 3347400050 $1,103.22
DEVELOPMENT
$1,070.90
PERMIT FEE
R000.322.100.00.00
$646.30
PLAN CHECK FEE
R000.345.830.00.00
$420.10
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$32.32
TECHNOLOGY FEE
R000.322.900.04.00
$32.32
D14-0008 Address: 4811 S 124 ST
Apn: 0179003115 $1,103.22
DEVELOPMENT
$1,070.90
PERMIT FEE
R000.322.100.00.00
$646.30
PLAN CHECK FEE
R000.345.830.00.00
$420.10
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$32.32
TECHNOLOGY FEE
R000.322.900.04.00
$32.32
D14-0009 Address: 12216 47 AVE S
Apn: 0179001140 $924.38
DEVELOPMENT
$897.32
PERMIT FEE
R000.322.100.00.00
$541.10
PLAN CHECK FEE
R000.345.830.00.00
$351.72
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$27.06
TECHNOLOGY FEE
R000.322.900.04.00
$27.06
D14-0010 Address: 5702 S PAMELA
DR Apn: 7344000020 $1,077.20
DEVELOPMENT
$1,045.65
PERMIT FEE
R000.322.100.00.00
$631.00
PLAN CHECK FEE
R000.345.830.00.00
$410.15
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 1 of 11
SYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
ACCOUNT I QUANTITY I PAID
$30,413.70
D14-0010 Address: 5702 S PAMELA
DR Apn: 7344000020 $1,077.20
TECHNOLOGY FEE
$31.55
TECHNOLOGY FEE
R000.322.900,04.00
$31.55
D14-0011 Address: 4702 S 124 ST
Apn: 0179001210 $857.74
DEVELOPMENT
$832.64
PERMIT FEE
R000.322.100.00.00
$501.90
PLAN CHECK FEE
R000.345.830.00.00
$326.24
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$25.10
TECHNOLOGY FEE
R000.322.900.04.00
$25.10
D14-0012 Address: 12212 46 AVE S
Apn: 0179000910 $1,129.22
DEVELOPMENT
$1,096.14
PERMIT FEE
R000.322.100.00.00
$661.60
PLAN CHECK FEE
R000.345.830.00.00
$430.04
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$33.08
TECHNOLOGY FEE
R000.322.900.04.00
$33.08
D14-0013 Address: 11870 44 PL S
Apn: 3347400790 $957.70
DEVELOPMENT
$929.66
PERMIT FEE
R000.322.100.00.00
$560.70
PLAN CHECK FEE
R000.345.830.00.00
$364.46
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$28.04
TECHNOLOGY FEE
R000.322.900.04.00
$28.04
D14-0014 Address: 4716 S 122 ST
Apn: 3347401455 $1,103.22
DEVELOPMENT
$1,070.90
PERMIT FEE
R000.322.100.00.00
$646.30
PLAN CHECK FEE
R000.345.830.00.00
$420.10
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$32.32
TECHNOLOGY FEE
R000.322.900.04.00
$32.32
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 2 of 11
SYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
I ACCOUNT QUANTITY I PAID
$30,413.70
D14-0015 Address: 4920 S 114 ST
Apn: 3348401711 $1,077.20
DEVELOPMENT
$1,045.65
PERMIT FEE
R000.322.100.00.00
$631.00
PLAN CHECK FEE
R000.345.830.00.00
$410.15
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$31.55
TECHNOLOGY FEE
R000.322.900.04.00
$31.55
D14-0016 Address: 13049 56 AVE S
Apn: 2172000060 $1,285.28
DEVELOPMENT
$1,247.61
PERMIT FEE
R000.322.100.00.00
$753.40
PLAN CHECK FEE
R000.345.830.00.00
$489.71
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$37.67
TECHNOLOGY FEE
R000.322.900.04.00
$37.67
D14-0017 Address: 12055 44 AVE 51
Apn: 3347400420 $657.82
DEVELOPMENT
$638.60
PERMIT FEE
R000.322.100.00.00
$384.30
PLAN CHECK FEE
R000.345.830.00.00
$249.80
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$19.22
TECHNOLOGY FEE
R000.322.900.04.00
$19.22
D14-0018 Address: 12404 50 PL S
Apn: 0179002265 $1,207.26
DEVELOPMENT
$1,171.88
PERMIT FEE
R000.322.100.00.00
$707.50
PLAN CHECK FEE
R000.345.830.00.00
$459.88
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$35.38
TECHNOLOGY FEE
R000.322.900.04.00
$35.38
D14-0019 Address: 11836 44 AVE S
Apn: 3347401015 $1,363.32
DEVELOPMENT
$1,323.35
PERMIT FEE
R000.322.100.00.00
$799.30
PLAN CHECK FEE
R000.345.830.00.00
$519.55
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 3 of 11
SYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
ACCOUNT QUANTITY PAID
$30,413.70
D14-0019 Address: 11836 44 AVE 5
Apn: 3347401015 $1,363.32
TECHNOLOGY FEE
$39.97
TECHNOLOGY FEE
R000.322.900.04.00
$39.97
D14-0020 Address: 12012 44 AVE S
Apn: 3347401060 $857.74
DEVELOPMENT
$832.64
PERMIT FEE
R000.322.100.00.00
$501.90
PLAN CHECK FEE
R000.345.830.00.00
$326.24
WASHINGTON STATE SURCHARGE
8640.237.114
$4.50
TECHNOLOGY FEE
$25.10
TECHNOLOGY FEE
R000.322.900.04.00
$25.10
D14-0021 Address: 12020 42 AVE 5
Apn: 3347400290 $1,493.36
DEVELOPMENT
$1,449.57
PERMIT FEE
R000.322.100.00.00
$875.80
PLAN CHECK FEE
R000.345.830.00.00
$569.27
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$43.79
TECHNOLOGY FEE
R000.322.900.04.00
$43.79
D14-0022 Address: 4925 S 125 ST
Apn: 0179002840 $1,259.28
DEVELOPMENT
$1,222.37
PERMIT FEE
R000.322.100.00.00
$738.10
PLAN CHECK FEE
R000.345.830.00.00
$479.77
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$36.91
TECHNOLOGY FEE
R000.322.900.04.00
$36.91
D14-0023 Address: 1223146 AVE S
Apn: 0179000840 $857.74
DEVELOPMENT
$832.64
PERMIT FEE
R000.322.100.00.00
$501.90
PLAN CHECK FEE
R000.345.830.00.00
$326.24
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$25.10
TECHNOLOGY FEE
R000.322.900.04.00
$25.10
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 4 of 11
SYSTEMS
Cash Register Receipt
City of Tukwila
Receipt Number
DESCRIPTIONS
PermitTRAK
ACCOUNT QUANTITY PAID
$30,413.70
D14-0024 Address: 4702 S 122 ST Apn: 3347401430 $924.38
DEVELOPMENT
$897.32
PERMIT FEE
R000.322.100.00.00
$541.10
PLAN CHECK FEE
R000.345.830.00.00
$351.72
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$27.06
TECHNOLOGY FEE
R000.322.900.04.00
$27.06
D14-0025 Address: 11608 40TH AVE S
Apn: 7340600140 $1,545.38
DEVELOPMENT
$1,500.06
PERMIT FEE
R000.322.100.00.00
$906.40
PLAN CHECK FEE
R000.345.830.00.00
$589.16
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$45.32
TECHNOLOGY FEE
R000.322.900.04.00
$45.32
D14-0026 Address: 13007 57TH AVE S
Apn: 2137000020 $791.10
DEVELOPMENT
$767.96
PERMIT FEE
R000.322.100.00.00
$462.70
PLAN CHECK FEE
R000.345.830.00.00
$300.76
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$23.14
TECHNOLOGY FEE
R000.322.900.04.00
$23.14
D14-0027 Address: 12239 46 AVE S
Apn: 0179000830 $857.74
DEVELOPMENT
$832.64
PERMIT FEE
R000.322.100.00.00
$501.90
PLAN CHECK FEE
R000.345.830.00.00
$326.24
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$25.10
TECHNOLOGY FEE
R000.322.900.04.00
$25.10
D14-0040 Address: 11664 44 AVE S
Apn: 3347400690 $1,389.32
DEVELOPMENT
$1,348.59
PERMIT FEE
R000.322.100.00.00
$814.60
PLAN CHECK FEE
R000.345.830.00.00
$529.49
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 5 of 11
SYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
ACCOUNT QUANTITY I
PAID
PermitTRAK
$30,413.70
D14-0040 Address: 11664 44 AVE S
Apn: 3347400690
$1,389.32
TECHNOLOGY FEE
$40.73
TECHNOLOGY FEE
R000.322.900.04.00
$40.73
M14-0005 Address: 4928 S 113 ST
Apn: 3348401741
$233.88
MECHANICAL
$224.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
$44.98
TECHNOLOGY FEE
$9.00
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
M14-0006 Address: 4230 S 116 ST
Apn: 3347400050
$221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0007 Address: 4811 S 124 ST
Apn: 0179003115
$221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102:00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0008 Address: 12216 47 AVE S
Apn: 0179001140
$221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 6 of 11
APVIPARAff
SYSTEMS
Cash Register Receipt
City of Tukwila
290
Receipt Number
R1222
DESCRIPTIONS
I ACCOUNT I QUANTITY I PAID
PermitTRAK
$30,413.70
M14-0009 Address: 5702 S PAMELA
DR Apn: 7344000020 $233.88
MECHANICAL
$224.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
$44.98
TECHNOLOGY FEE
$9.00
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
M14-0010 Address: 4702 S 124 ST
Apn: 0179001210 $221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0011 Address: 4928 S 113 ST
Apn: 3348401741 $221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0012 Address: 11870 44 PL S
Apn: 3347400790 $221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0013 Address: 4716 S 122 ST
Apn: 3347401455 $221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 7 of 11
YS L JA
Cash Register Receipt
City of Tukwila
Receipt Number
R1222
DESCRIPTIONS
PermitTRAK
I ACCOUNT ( QUANTITY I PAID
$30,413.70
M14-0013 Address: 4716 S 122 ST
Apn: 3347401455 $221.32
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0014 Address: 4920 S 114 ST
Apn: 3348401711 $221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0015 Address: 13049 56 AVE S
Apn: 2172000060 $246.42
MECHANICAL
$236.94
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$157.05
PLAN CHECK FEE
R000.322.102.00.00
$47.39
TECHNOLOGY FEE
$9.48
TECHNOLOGY FEE
R000.322.900.04.00
$9.48
M14-0016 Address: 12055 44 AVE S 1
Apn: 3347400420 $221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100:00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0017 Address: 12404 50 PL S
Apn: 0179002265 $233.88
MECHANICAL
$224.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
$44.98
TECHNOLOGY FEE
$9.00
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 8 of 11
el Ig,9AI9I /,
SYSTEMS
DESCRIPTIONS
I ACCOUNT
QUANTITY I
PAID
PermitTRAK
$30,413.70
M14-0018 Address: 11836 44 AVE S
Apn: 3347401015
$246.42
MECHANICAL
$236.94
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$157.05
PLAN CHECK FEE
R000.322.102.00.00
$47.39
TECHNOLOGY FEE
$9.48
TECHNOLOGY FEE
R000.322.900.04.00
$9.48
M14-0019 Address: 12012 44 AVE S
Apn: 3347401060
$221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0020 Address: 12020 42 AVE S
Apn: 3347400290
$221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0021 Address: 4925 S 125 ST
Apn: 0179002840
$246.42
MECHANICAL
$236.94
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$157.05
PLAN CHECK FEE
R000.322.102.00.00
$47.39
TECHNOLOGY FEE
$9.48
TECHNOLOGY FEE
R000.322.900.04.00
$9.48
M14-0022 Address: 1223146 AVE S
Apn: 0179000840
$221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 9 of 11
IIf
SY'51EMS
Cash Register Receipt
City of Tukwila
Receipt Number
DESCRIPTIONS I ACCOUNT
PermitTRAK
QUANTITY PAID
$30,413.70
M14-0022 Address: 1223146 AVE S Apn: 0179000840 $221.32
TECHNOLOGY FEE $8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0023 Address: 4702 S 122 ST Apn: 3347401430 $233.88
MECHANICAL $224.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
$44.98
TECHNOLOGY FEE $9.00
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
M14-0024 Address: 11608 40TH AVE S Apn: 7340600140 $233.88
MECHANICAL $224.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
$44.98
TECHNOLOGY FEE $9.00
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
M14-0025 Address: 13007 57TH AVE S Apn: 2137000020 $233.88
MECHANICAL $224.88
PERMIT ISSUANCE BASE FEE
R000.322.100:00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
$44.98
TECHNOLOGY FEE $9.00
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
M14-0026 Address: 12239 46 AVE S Apn: 0179000830 $221.32
MECHANICAL $212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE $8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 10 of 11
ew'1"'ffor1/""1l!
SYSTEMS
DESCRIPTIONS
PermitTRAK
I ACCOUNT ) QUANTITY
I PAID
$30,413.70
M14-0030 Address: 11664 44 AVE S
Apn: 3347400690
$233.88
MECHANICAL
$224.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
$44.98
TECHNOLOGY FEE
$9.00
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
TOTAL FEES PAID BY RECEIPT: R1222
$30,413.70
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 11 of 11
111 -CMGtZ
6()
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
Project:
t. k t ''- k..`irl U-. :. '''S
Type of Inspection: _
7 :(:) <<, i t - , is..,
Address:
I t t, 7 - t-I Li' ti3L
Date Called:
Special Instructions:
Date Wanted:
— 1 --
l L f
(a.m.
p.m.
Requester:
i.)AJe_
Phone No:
ElApproved per applicable codes.
Corrections required prior to approval.
COMMENTS:
(. I) Rtilr,() - ,,.�
r't.1 ;) )iCV,C1
-.
' /
inspect r:
�"titn ti9---7 I i a Jr\ e
I
Date
c�-
1 �
R INSPECTION FEE REQUIF�ED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
City of Tukwila
Department of Community Development
January 15, 2014
Sharyn Parker
7277 Perimeter Rd S
Seattle, WA 98108
Jim Haggerton, Mayor
Jack Pace, Director
RE: Correction Letter #
Mechanical Application Number M14-0005 through M14-0015 and M14-0018 through M14-0026
King County Noise Remediation Program
Dear Sharyn Parker,
This letter is to inform you of corrections that must be addressed before your development permit can be approved. All
correction requests from each department must be addressed at the same time and reflected on your drawings. I have
enclosed comments from the following departments:
BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments.
(GENERAL NOTE)
PLAN SUBMITTALS: Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised
plan sheets shall be the same size sheets as those previously submitted.
1. All mechanical notes calculations, table titles and references refer to either Seattle Residential codes (SRC) or
outdated WAC and WSEC code references. Revise all notes, calculations, table titles and any related references to
show compliance with 2012 International Residential Codes (IRC) as adopted by the City of Tukwila. This also
shall include compliance with the related codes 2012 WSEC, IMC and IBC codes.
Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other
documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be
resubmitted with the appropriate revision block.
In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have
enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail
or by a messenger service.
If you have any questions, I can be reached at 206-433-7165.
File No. M14-0005 thru M14-0015 & M14-0018 thru M14-0026
6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M14-0012
PROJECT NAME: Quicksall Residence
SITE ADDRESS: 11870 44th P1. S.
Original Plan Submittal
X Response to Correction Letter # 1
DATE: 02/06/13
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
Building Division
Public Works n
Fire Prevention
Structural
Planning Division
Permit Coordinator
PRELIMINARY REVIEW:
Not Applicable ❑
(no approval/review required)
DATE: 02/11/14
Structural Review Required
REVIEWER'S INITIALS: DATE:
n
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
DUE DATE: 03/11/14
Approved with Conditions kr
Denied
(corrections entered in Reviews) (ie: Zoning Issues)
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M14-0012 DATE: 01/10/2014
PROJECT NAME: Quicksall Residence
SITE ADDRESS: 11870 44 P1 S
X Original Plan Submittal
Response to Correction Letter #
Revision #
Revision #
before Permit Issued
after Permit Issued
DEPARTMENTS:
Clenft-VeJ 114`1("i
wilding Division pp
Public Works n
Fire Prevention
Structural
Planning Division
Permit Coordinator
111
PRELIMINARY REVIEW:
Not Applicable n
(no approval/review required)
DATE: 01/14/14
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved ❑
Corrections Required
(corrections entered in Reviews
Approved with Conditions
Denied
(ie: Zoning Issues)
DUE DATE: 02/11/14
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only 01,64
CORRECTION LETTER MAILED: 1 I
Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials:/��
12/18/2013
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Web site: http://www.TukwilaWA.gov
REVISION
SUBMITTAL
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date: January 23rd, 2014
Plan Check/Permit Number: M 14-0012
❑ Response to Incomplete Letter #
® Response to Correction Letter # 1
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Project Name:
Project Address:
Contact Person:
Summary of Revision:
Quicksall Residence
11870 44 P1 S
Sharyn Parker
RECEIVED
CITY OF TUKWILA
FEB 0 6 2014
PERMIT CENTER
Phone Number: 206 296-7437
Revised all code references to show compliance with:
2012 Washington State Energy Code, Residential
2012 International Building Code
WAC 51-51 (Washington State Amendments to 2012 IBC)
Obsolete and incorrect references were corrected and marked with a revision cloud.
Code references found to be accurate and compliant with the 2012 codes cited above
were left unchanged and unmarked.
SheetNumber(s): M1.0., M2.0
"Cloud" or highlight all areas of revision including date of revision
Received at the City of Tukwila Permit Center by:
14 Entered in Permits Plus on
W:1Permit Center&Rcvision Submittal Form - Merge.doc
Revised: May 2011
G & G SPECIALTY CONTRCTORF "NNC
Page 1 of 2
Washington State lDepartment of
Labor & Industries
G & G SPECIALTY CONTRCTORS INC
Owner or tradesperson
GOODBALLET, JAMES SCOTT
Principals
GOODBALLET, JAMES SCOTT, PRESIDENT
GOODBALLET, TERESA LYNN, SECRETARY
GOODBALLET, CHARLES ELMER, CHIEF
EXECUTIVE OFFICER
WAVY, CHRISTINE, CHIEF OPERATING
OFFICER
Doing business as
G & G SPECIALTY CONTRCTORS INC
WA UBI No.
602 975 812
Parent company
G & G SPECIALTY CONTRCTORS INC
1221 N. Monde! DR
GILBERT, AZ85233
480-921-4079
Business type
Corporation
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor
License specialties
GENERAL
License no.
GGSPEGS919RT
Effective — expiration
12/31/2009-12/31/2015
Bond
HARTFORD FIRE INS CO
Bond account no.
59BSBEA9058
Active.
Meets current requirements.
$12,000.00
Received by L&I Effective date
01/03/2011 12/18/2010
Bond history
Insurance
National Union Fire Ins of PA $1,000,000.00
Policy no.
xnd0055800
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602975812&LIC=GGSPEGS919RT&SAW= 05/19/2014
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CIRC
COND
CON T
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
HWS
LAT
LWG
LWT
MAX
MBH
MCA
MIN
MTG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
oC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SG
SHT
SM
SO
SP
SPD
SPEC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
WB
W/
WAC
WSEC
ABBREVIATIONS
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INTERNATIONAL RESIDENTIAL CODE
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SUPPLY DIFFUSER
SHEET
SHEET METAL
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WASHINGTON ADMINISTRATIVE CODE
WASHINGTON STATE ENERGY CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
4o,
LEGEND
ABBR
OR XX
0
X/Y
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
SYMBOL ABBR
SG—X
XXX
DN I DN
*NJ
UP
VD
RA/EA
RG
--I—) SA
-01- 0- I-
0 —)
0 0-
(.(2R (Rs
EQUIP ID#Z•
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DUCT OFFSET DOWN IN
FLOW DIRECTION
DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SA SUPPLY AIR DUCT
RA/EA
SD
EA
MOD
NG NG
•
0
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
CEILING SUPPLY GRILLE
CEILING RETURN GRILLE
EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION — RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
THERMOSTAT
EQUIPMENT LOCATION
MOTOR OPERATED DAMPER
NATURAL GAS PIPE
PIPE/DUCT ELBOW DOWN
PIPE/DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
rrd o_r_tdonal pion re,!invs f
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MECHANICAL PLANS AND DETAILS
DRAWING INDEX
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
N
T
TOR .AL LD IF L DIN ND D SI' BE • E NNh CO m UC
I •
0
RD G 0 IPM
OT AL OM AN
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET 2012 WASHINGTON STATE ENERGY CODE (WSEC) RESIDENTIAL.
SECTION 4, 403.2.1 REQUIREMENTS.
C • K ETR
AIRTIGHT.
6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
ON RO
,C GS D R
• •
IN
SH B AL AIR
01
RAL •LU
PE
GH
P
CTS
ALL
8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
THERMOSTATS 41-0" AFF. UNLESS NOTED OTHERWISE.
9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
10. MAINTAIN 101-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
12. MAINTAIN 3'-0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
MECHANICAL/ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
DESCRIPTION
VOLTS
PH
23
26
23
26
N/A
23
26
N/A
BV-1
BLENDING UNIT VENTILATOR
120
1
X
X
X
1,2
—
SWITCHES (ON, 'TIMER)
120
1
X
X
X
1
REMARKS:
1 — VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 — DISCONNECT SWITCH
BLENDING UNIT VENTILATOR
MARK
CFM
EXTERNAL
STATIC
DIMENSIONS
ELECTRICAL
COMMENTS
WATTS
VOLTS
PHASE
BV-1
140
.5" WG
32"Lx12.25"Wx8.5"H
76
120
1
1, 2, 3
NOTE:
1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER.
2. PROVIDE WITH SPEED CONTROL
3. BASIS OF DESIGN: ALOES AMERICAN
A. OR APPROVED EQUAL.
GRILLE AND DIFFUSER SCHEDULE
STATIC
INLET OR NECK
DUCT
MARK
CFM
PRESSURE _
SIZE
CONNECTION
LOCATION
MODEL #
REMARKS
SG-1
70
<.08" WG
6"
6"
CEILING
ALLGRILLE
1, 2, 4
SG-2
70
<.08" WG
6"
6"
WALL
ALGRILLE
1, 2, 4
OG-1
90
<08" WG
7"
7"
WALL
WALL CAP
1, 2, 3, 4
RG-1
25
<.08" WG
4"
4"
CEILING
DECO
1, 2, 4
REMARKS:
1. INSTALL PER MANUFACTURER'S
WRITTEN INSTRUCTIONS
5. BASIS OF DESIGN: SHOEMAKER
2 PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE A. OR APPROVED EQUAL
3. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 6. PROVIDE WITH AN OPPOSED BLADE DAMPER
4. BASIS OF DESIGN: ALDES
A. OR APPROVED EQUAL
.0----....e" ...--...
IRC 2012
RESIDENCE CODE
FLOOR AREA
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
41
0
CF
9 M
.0
1. VENTILATION PROVIDED PER 2012 IRC, SECTION M1507, TABLES M1507.3.3(1) AND M1507.3.3(2), AND
WAC CHAPTER 51-51, SECTION M1507
)
.1\
.1\
.1\
-.MN/ -•••••••••- '••••••••••' -•••••••••.' '••••••••• •....m100' .....emg./... ....ft....0'r
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION MIN VALUE INOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R-8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR/CEILING
R-8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R-8
1,3
IN CEMENT SLAB OR IN GROUND
R-5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS
MEDIUM NOT INCLUDING FINISHING MATERIALS.
OF THE BASIC INSULATING
WHICH IS LOCATED WITHIN A WALL
EXPOSED TO UNCONDITIONED AIR
OR
AND
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT
FLOOR/CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE
3. REFER TO 2012 WASHINGTON STATE ENERGY CODE (WSEC)
REQUIREMENTS.
RESIDENTIAL FOR ADDITIONAL
,
SEPARATE PERMIT
REQUIRED FOR
gMechanical
Electrical
Plumbing
Gas MORI
City of Tukwila
IILDING DIVISION
DRAWING NOTES:
REVIEWED
CODE COMP
APPROV
FEB 1 9 2
FOR
IANCE
D
14
13U161.04YIN°G • IVISilaION
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS
RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW
THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR
EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO
START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING
ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY,
QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT.
REFER TO SECTIONS 011101 AND 028200 FOR REGULATED
MATERIALS ABATEMENT.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED
TO EXISTING EXTERIOR SIDING AND WINDOW TRIM PAINT.
FILE C
Permit No. WW4 00 t'2-
Plan review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Field Copy and conditions is cknowledged:
Date:
11
VENTILATION SCHEDULE
BUILDING DIVI ION
SET BV-1 SWITCH TO OPERATE VENTILATION UNIT A MINIMUM 2 HOURS OF EVERY 4—HOUR
SEGMENT.
MECHANICAL VENTILATION CALCULATION
PER IRC M1507.3.3
FROM TABLE M1507.3.3(1)
CONTINUOUS VENTILATION SYSTEM AIRFLOW REQUIREMENT: 45 CFM
FROM TABLE M1507.3.3(2)
VENTILATION SYSTEM RUN TIME PERCENTAGE IN EACH 4—HOUR SEGMENT: 50%
INTERMITTENT WHOLE —HOUSE MECHANICAL VENTILATION RATE FACTOR: 2
REQUIRED VENTILATION RATE: 4,5/2_=90 CFM
RECEIVED
CITY OF TUKWILA
FEB 0 6 2014
PERMIT CENTER
CORRECTION
LTR#
S.M. STEMPER
ARCHITECTS
A Protasaloned Waned LlabUtity Company
4000 DELRIDGE WAY SW
SUITE 200 SEATTLE, WA 90106
(206) 024-2777 FAX (206) 024-2973
THE GREENBUSCH GROUP, INC
04i • • • s •
19ACF10 STh1.4111211ERS0153T AUI" SIVT ILA 201 SEAM& 1VA 95110
(208) 378-0569 (208) 378-0641 FAX
081003.2541
w
w
0
CL
0
w
w
w
ct
ct
AIP NUMBER
3-53-0058-047
0
0
co
F—
DATE
07/19/2013
ISSUED 100% CD
PROJECT ENGINEER
DT
PROJECT MANAGER
DT
DRAWN
JA
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
EXPIRES: 9/08/2014
INDOOR
PATIO
CLOSET
tli
25
SEE TYP ALL
CEILING GRILLES
BEDROOM
2
PATIO
SOFFIT, REFER TO
ARCHITECTURAL
6"0 UP
BATH
001-
RG-1
25
BEDROOM
1
TO 13V-1
SG-1
70
K TCH EN
DINING
ROOM
SEE TYP ALL
WALL GRILLES
(E) WOOD STOVE
LIVING
ROOM
MAIN FLOOR MECHANICAL PLAN
SCALE: 1/4" = 11-0"
NORTH
ATTIC
MOTOR AND
FILTER ACCESS
RETURN AIR
DUCT
OUTSIDE AIR
DUCT
SUPPLY AIR DUCT
(E)ACCESS PANEL
STRAP TO STRUCTURE
PER MANUFACTURER'S
WRITTEN
INSTRUCTIONS.
NOTES:
1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION.
2. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
3. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCH
SIZE AND LOCATION WITH ARCHITECT.
C) BV-1 INSTALLATION DETAIL
SCALE: NONE
FOAM BACKER
ROD, TYP
CAULK, TYP
SHEETMETAL
TRANSITION TO WALL
CAP NECK SIZE
FLEX DUCT
PER PLAN
NOTES:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORDINATE WITH ARCHITECTURAL DETAIL DRAWINGS.
li
®WALL CAP DETAIL
SCALE: NONE
4"0 DN
TO RG-1
L
OG-1
90
NEW 24" X 30"
ATTIC ACCESS
PANEL
rciTv.s• SEE
7 Co I
TO
TIMER
SWITCH
L
SG-2
70
6"0
6"0 DN
TO SG-1
STUDY
1
1
ATTIC MECHANICAL PLAN
SCALE: 1/4" = 1'-0"
(E)SIDING
SHEET METAL
FLASHING
2X2 BLOCKING
WALL CAP
2X2 BLOCKING
2X2 BLOCKING
SHEETMETAL
TRANSITION TO
DIFFUSER NECK
SIZE
2X BLOCKING
SLEEVE AND
ESCUTCHEON
GRILLE
NORTH
DUCT PER PLAN
FIELD FABRICATE
PLENUM BEHIND
CEILING GRILLE
FOAM BACKER ROD
CAULK
2X BLOCKING
FLOOR OR
CEILING JOIST
CEILING
NOTES:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. CEILING SUPPLY INSTALLATION SHOWN, RETURN SIMILAR.
CEILING GRILLE DETAIL
SCALE: NONE
DRAWING
NOTES:
1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR
3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51-51
SECTION M1507.3.6.5.
2. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK-OUT WORK HAS BEEN
COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE
FOLLOW NG:
A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING AIR
UNIT SYSTEM(S) WITH NEW FILTERS.
FLAG NOTES:
BV-1 AND DUCTWORK ROUTED IN ATTIC. COORDINATE ELECTRICAL AND
MAINTENANCE ACCESS HATCH WITH TECHNICAL REPRESENTATIVE.
ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SW TCH BY TECHNICAL
SPECIFICATIONS SECTION 260010. AFFIX A LABEL TO THE CONTROLLER
THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING
INSTRUCTIONS)" PER WAC 51-51 SECTION M1507.3.2. COORDINATE FINAL
SWITCH LOCATION WITH HOMEOWNER.
TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE
MAKING FINAL GRILLE OR DIFFUSER CONNECTION.
PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR
INLET, REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL
SPECIFICATIONS.
INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT
INSULATION THICKNESS SCHEDULE ON M1.0.
SHEETMETAL "Y" FITTING WITH VOLUME DAMPERS.
CAULK
SHEETMETAL
TRANSITION TO
GRILLE NECK SIZE
DUCT PER PLAN
2X BLOCKING
REVIEITV115F6k--
CODE COMPLIANCE
APPROVED
FEB 19 2014
City of Tukwila
BUILDING DIVISION
M I oo
2X BLOCKING
FOAM BACKER
ROD
WALL GRILLE
SLEEVE AND
ESCUTCHEON
WALL
NOTES:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. WALL SUPPLY INSTALLATION SHOWN, RETURN SIMILAR.
WALL GRILLE DETAIL
SCALE: NONE
RECEIVED
CITY OF TUKWILA
FEB 0 6 2014
PERMIT CENTER
S.M. STEMPER
ARCHITECTS
A Professional Malted Liability Company
4000 DELRIDGE WAY SW
SUITE 200 SETTLE, WA 98106
(208) 624-277? FAX (200) 04-2073
THE GREENBUSCH GROUP, INC
• 6 • Oa • 41)))
lee Tic" -war NifeRsoi'm tIATE 201 391111E. IVA Eti
16119
(2011) 378-0589 (208) 378-0641 FAX
0810.03.2541
z
0
z
EDY IMPROVEMENTS
AIP NUMBER
3-53-0058-047
TUKWILA VVASHINGTON
DATE
• 07/19/2013
ISSUED 100% CD
PROJECT ENGINEER
DT
PROJECT MANAGER
DT
DRAWN
JA
MECHANICAL
PLANS AND
DETAILS
EXPIRES: 9/08/2014