HomeMy WebLinkAboutPermit M14-0014 - MORI & WONG RESIDENCE - RENOVATION FOR RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTMORI & WONG
RESIDENCE
4920 S 114 ST
M14-0014
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
MECHANICAL PERMIT
Parcel No: 3348401711
Address: 4920 S 114 ST
Project Name: MORI & WONG RESIDENCE
Permit Number: M14-0014
Issue Date: 5/19/2014
Permit Expires On: 11/15/2014
Owner:
Name: MORI ALAINA M+WONG ANDREW Q
Address: 4920 S 114TH ST , TUKWILA, WA,
98178
Contact Person:
Name: SHARYN PARKER Phone: (206) 296-7437
Address: 7277 PERIMETER RD S , SEATTLE, WA,
98108
Contractor:
Name: G & G SPECIALTY CONTRCTORS INC
Address: 4633 S 36 ST , PHOENIX, AZ, 85040
License No: GGSPEGS919RT
Lender:
Name:
Address:
II I
Phone: (480) 921-4079
Expiration Date: 12/31/2015
DESCRIPTION OF WORK:
MECHANICAL RENOVATION OF SINGLE FAMILY HOME REQUIRE FOR PARTICIPATION IN FAA (RANRIP)
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM TO REDUCE NOISE FILTRATION. THIS WORK
MAY INCLUDE STAND ALONG BLENDING UNIT VENTILATION SYSTEM WITH ASSOCIATED DUCTING AND/OR
VOLUME DAMPER INSTALLATION TO EXISTING FURNACE WITH EXISTING DUCTING
Valuation of Work: $1,734.00
Type of Work:
Fuel type:
Fees Collected: $221.32
Electrical Service Provided by: SEATTLE CITY LIGHT
Water District: TUKWILA
Sewer Distric: NONE
Current Codes adopted by the City of Tukwila:
Internations Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
2012 International Fuel Gas Code:
2012 WA Cities Electrical Code:
2012 WA State Energy Code:
2012
2012
2012
2012
Permit Center Authorized Signature: j\NNAC44.
Date:
Al lig
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature: /4/
Print Name: //(� " 11i1 Pi
Date: %' /y• / y
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or
if the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***BUILDING PERMIT CONDITIONS***
2: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
3: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector
based on satisfactory completion of this requirement.
5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the
City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or
other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
8: All mechanical work shall be inspected and approved under a separate permit issued by the City of
Tukwila Permit Center (206/431-3670).
9: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
10: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired
appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces:
Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms.
11: Equipment and appliances having an ignition source and located in hazardous locations and public
garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking
garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface
on which the equipment or appliance rests.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1800 MECHANICAL FINAL
0701 ROUGH -IN MECHANICAL
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Soulhcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Mechanical Permit No.
Project No.
Date Application Accepted:
Date Application Expires:
VI V4 00 l�
01, to t o-I
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION
King Co Assessor's Tax No.: 3348401711
Site Address: 4920 S. 114th St. Suite Number:
Tenant Name:
PROPERTY OWNER
Name:
JJ(fj
Address:
J
City:
State:
Zip:
CONTACT PERSON — person receiving all project
communication
Name: Sharyn Parker
Address: 7277 Perimeter Road South
City: Seattle State: WA Zip: 98106
Phone: (206) 296-7437 Fax: (206) 269-7315
Email: Sharyn.Parker@kingcounty.gov
Floor:
New Tenant: ❑ Yes I ..No
MECHANICAL CONTRACTOR INFORMATION
Company Name: not yet awarded
Address:
City: State:
Zip:
Phone: Fax:
Contr Reg No.:
Exp Date:
Tukwila Business License No.:
Valuation of project (contractor's bid price): $ 1,734
Describe the scope of work in detail:
Mechanical renovation of single-family home required for participation in FAA (RANRIP) Residential Aircraft Noise Remedy
Improvements Program to reduce noise infiltration. This work may include: stand-alone blending unit ventilation system with
associated ducting and / or volume damper installation to existing furnace with existing ducting.
Use: Residential: New ❑ Replacement ❑
Commercial: New ❑ Replacement ❑
Fuel Type: Electric ❑ Gas ❑ Other:
H:\Applications\Forma-Applications On Line\201 I Applications\Mechanical Permit Application Revised 8.9.11.docx
Revised: August 2011
bh
Page 1 of 2
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Furnace >100k btu
Floor furnace
Suspended/wall/floor
mounted heater
Appliance vent
Repair or addition to
heat/refrig/cooling
system
Air handling unit
<10,000 cfm
Unit Type
Qty
Air handling unit
>10,000 cfm
Evaporator cooler
Ventilation fan
connected to single duct
Ventilation system
1
Hood and duct
Incinerator — domestic
Incinerator —
comm/industrial
Unit Type
Qty
Fire damper
Diffuser
Thermostat
Wood/gas stove
Emergency generator
Other mechanical
equipment
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNE R AU HORIZED AGENT:
Signature: Date: 1 k/ G1( (`f
Print Name: , Timoth nlason Day Telephone: (206) 624-2777
Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106
City State Zip
H:Wpplications\Forms-Applications On Line12011 Applications\Mechanical Permit Application Revised 8-9-11.docx
Revised: August 2011
bh
Page 2 of 2
DESCRIPTIONS
PermitTRAK
ACCOUNT QUANTITY PAID
$30,413.70
D14-0006 Address: 4928 S 113 ST
Apn: 3348401741 $1,337.30
DEVELOPMENT
$1,298.10
PERMIT FEE
R000.322.100.00.00
$784.00
PLAN CHECK FEE
R000.345.830.00.00
$509.60
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$39.20
TECHNOLOGY FEE
R000.322.900.04.00
$39.20
D14-0007 Address: 4230 S 116 ST
Apn: 3347400050 $1,103.22
DEVELOPMENT
$1,070.90
PERMIT FEE
R000.322.100.00.00
$646.30
PLAN CHECK FEE
R000.345.830.00.00
$420.10
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$32.32
TECHNOLOGY FEE
R000.322.900.04.00
$32.32
D14-0008 Address: 4811 S 124 ST
Apn: 0179003115 $1,103.22
DEVELOPMENT
$1,070.90
PERMIT FEE
R000.322.100.00.00
$646.30
PLAN CHECK FEE
R000.345.830.00.00
$420.10
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$32.32
TECHNOLOGY FEE
R000.322.900.04.00
$32.32
D14-0009 Address: 12216 47 AVE S
Apn: 0179001140 $924.38
DEVELOPMENT
$897.32
PERMIT FEE
R000.322.100.00.00
$541.10
PLAN CHECK FEE
R000.345.830.00.00
$351.72
WASHINGTON STATE SURCHARGE
8640.237.114
$4.50
TECHNOLOGY FEE
$27.06
TECHNOLOGY FEE
R000.322.900.04.00
$27.06
D14-0010 Address: 5702 S PAMELA
DR Apn: 7344000020 $1,077.20
DEVELOPMENT
$1,045.65
PERMIT FEE
R000.322.100.00.00
$631.00
PLAN CHECK FEE
R000.345.830.00.00
$410.15
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 1 of 11
SYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
ACCOUNT QUANTITY PAID
PermitTRAK
$30,413.70
D14-0010 Address: 5702 S PAMELA
DR Apn: 7344000020 $1,077.20
TECHNOLOGY FEE
$31.55
TECHNOLOGY FEE
R000.322.900.04.00
$31.55
D14-0011 Address: 4702 S 124 ST
Apn: 0179001210 $857.74
DEVELOPMENT
$832.64
PERMIT FEE
R000.322.100.00.00
$501.90
PLAN CHECK FEE
R000.345.830.00.00
$326.24
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$25.10
TECHNOLOGY FEE
R000.322.900.04.00
$25.10
D14-0012 Address: 12212 46 AVE S
Apn: 0179000910 $1,129.22
DEVELOPMENT
$1,096.14
PERMIT FEE
R000.322.100.00.00
$661.60
PLAN CHECK FEE
R000.345.830.00.00
$430.04
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$33.08
TECHNOLOGY FEE
R000.322.900.04.00
$33.08
D14-0013 Address: 11870 44 PL S
Apn: 3347400790 $957.70
DEVELOPMENT
$929.66
PERMIT FEE
R000.322.100.00.00
$560.70
PLAN CHECK FEE
R000.345.830.00.00
$364.46
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$28.04
TECHNOLOGY FEE
R000.322.900.04.00
$28.04
D14-0014 Address: 4716 S 122 ST
Apn: 3347401455 $1,103.22
DEVELOPMENT
$1,070.90
PERMIT FEE
R000.322.100.00.00
$646.30
PLAN CHECK FEE
R000.345.830.00.00
$420.10
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$32.32
TECHNOLOGY FEE
R000.322.900.04.00
$32.32
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 2 of 11
SYSTEMS
Receipt Number
DESCRIPTIONS
ACCOUNT QUANTITY PAID
PermitTRAK
$30,413.70
D14-0015 Address: 4920 S 114 ST
Apn: 3348401711 $1,077.20
DEVELOPMENT
$1,045.65
PERMIT FEE
R000.322.100.00.00
$631.00
PLAN CHECK FEE
R000.345.830.00.00
$410.15
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$31.55
TECHNOLOGY FEE
R000.322.900.04.00
$31.55
D14-0016 Address: 13049 56 AVE S
Apn: 2172000060 $1,285.28
DEVELOPMENT
$1,247.61
PERMIT FEE
R000.322.100.00.00
$753.40
PLAN CHECK FEE
R000.345.830.00.00
$489.71
WASHINGTON STATE SURCHARGE
8640.237.114
$4.50
TECHNOLOGY FEE
$37.67
TECHNOLOGY FEE
R000.322.900.04.00
$37.67
D14-0017 Address: 12055 44 AVE S 1
Apn: 3347400420 $657.82
DEVELOPMENT
$638.60
PERMIT FEE
R000.322.100.00.00
$384.30
PLAN CHECK FEE
R000.345.830.00.00
$249.80
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
r
TECHNOLOGY FEE
$19.22
TECHNOLOGY FEE
R000.322.900.04.00
$19.22
D14-0018 Address: 12404 50 PL S
Apn: 0179002265 $1,207.26
DEVELOPMENT
$1,171.88
PERMIT FEE
R000.322.100.00.00
$707.50
PLAN CHECK FEE
R000.345.830.00.00
$459.88
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$35.38
TECHNOLOGY FEE
R000.322.900.04.00
$35.38
D14-0019 Address: 11836 44 AVE S
Apn: 3347401015 $1,363.32
DEVELOPMENT
$1,323.35
PERMIT FEE
R000.322.100.00.00
$799.30
PLAN CHECK FEE
R000.345.830.00.00
$519.55
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 3 of 11
SYSTE;N<
DESCRIPTIONS I ACCOUNT I QUANTITY I PAID
PermitTRAK $30,413.70
D14-0019 Address: 11836 44 AVE S Apn: 3347401015 $1,363.32
TECHNOLOGY FEE $39.97
TECHNOLOGY FEE
R000.322.900.04.00
$39.97
D14-0020 Address: 12012 44 AVE S Apn: 3347401060 $857.74
DEVELOPMENT $832.64
PERMIT FEE
R000.322.100.00.00
$501.90
PLAN CHECK FEE
R000.345.830.00.00
$326.24
WASHINGTON STATE SURCHARGE
6640.237.114
$4.50
TECHNOLOGY FEE $25.10
TECHNOLOGY FEE
R000.322.900.04.00
$25.10
D14-0021 Address: 12020 42 AVE S Apn: 3347400290 $1,493.36
DEVELOPMENT $1,449.57
PERMIT FEE
R000.322.100.00.00
$875.80
PLAN CHECK FEE
R000.345.830.00.00
$569.27
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE $43.79
TECHNOLOGY FEE
R000.322.900.04.00
$43.79
D14-0022 Address: 4925 S 125 ST Apn: 0179002840 $1,259.28
DEVELOPMENT $1,222.37
PERMIT FEE
R000.322.100.00.00
$738.10
PLAN CHECK FEE
R000.345.830.00.00
$479.77
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE $36.91
TECHNOLOGY FEE
R000.322.900.04.00
$36.91
D14-0023 Address: 1223146 AVE S Apn: 0179000840 $857.74
DEVELOPMENT $832.64
PERMIT FEE
R000.322.100.00.00
$501.90
PLAN CHECK FEE
R000.345.830.00.00
$326.24
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE $25.10
TECHNOLOGY FEE
R000.322.900.04.00
$25.10
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 4 of 11
SYS
DESCRIPTIONS
ACCOUNT QUANTITY PAID
PermitTRAK
$30,413.70
D14-0024 Address: 4702 S 122 ST Apn: 3347401430 $924.38
DEVELOPMENT
$897.32
PERMIT FEE
R000.322.100.00.00
$541.10
PLAN CHECK FEE
R000.345.830.00.00
$351.72
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$27.06
TECHNOLOGY FEE
R000.322.900.04.00
$27.06
D14-0025 Address: 11608 40TH AVE S
Apn: 7340600140 $1,545.38
DEVELOPMENT
$1,500.06
PERMIT FEE
R000.322.100.00.00
$906.40
PLAN CHECK FEE
R000.345.830.00.00
$589.16
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$45.32
TECHNOLOGY FEE
R000.322.900.04.00
$45.32
D14-0026 Address: 13007 57TH AVE S
Apn: 2137000020 $791.10
DEVELOPMENT
$767.96
PERMIT FEE
R000.322.100.00.00
$462.70
PLAN CHECK FEE
R000.345.830.00.00
$300.76
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$23.14
TECHNOLOGY FEE
R000.322.900.04.00
$23.14
D14-0027 Address: 12239 46 AVE S
I
Apn: 0179000830 $857.74
DEVELOPMENT
$832.64
PERMIT FEE
R000.322.100.00.00
$501.90
PLAN CHECK FEE
R000.345.830.00.00
$326.24
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
TECHNOLOGY FEE
$25.10
TECHNOLOGY FEE
R000.322.900.04.00
$25.10
D14-0040 Address: 11664 44 AVE S
Apn: 3347400690 $1,389.32
DEVELOPMENT
$1,348.59
PERMIT FEE
R000.322.100.00.00
$814.60
PLAN CHECK FEE
R000.345.830.00.00
$529.49
WASHINGTON STATE SURCHARGE
B640.237.114
$4.50
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 5 of 11
SYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
ACCOUNT QUANTITY PAID
$30,413.70
D14-0040 Address: 11664 44 AVE S
Apn: 3347400690 $1,389.32
TECHNOLOGY FEE
$40.73
TECHNOLOGY FEE
R000.322.900.04.00
$40.73
M14-0005 Address: 4928 S 113 ST
Apn: 3348401741 $233.88
MECHANICAL
$224.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
$44.98
TECHNOLOGY FEE
$9.00
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
M14-0006 Address: 4230 S 116 ST
Apn: 3347400050 $221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0007 Address: 4811 S 124 ST
Apn: 0179003115 $221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0008 Address: 12216 47 AVE S
Apn: 0179001140 $221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 6 of 11
SYSTEMS
DESCRIPTIONS
ACCOUNT QUANTITY PAID
PermitTRAK
$30,413.70
M14-0009 Address: 5702 S PAMELA
DR Apn: 7344000020 $233.88
MECHANICAL
$224.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
$44.98
TECHNOLOGY FEE
$9.00
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
M14-0010 Address: 4702 S 124 ST
Apn: 0179001210 $221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
-I
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0011 Address: 4928 S 113 ST
Apn: 3348401741 $221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0012 Address: 11870 44 PL S
Apn: 3347400790 $221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0013 Address: 4716 S 122 ST
Apn: 3347401455 $221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 7 of 11
srs re;A
DESCRIPTIONS
ACCOUNT QUANTITY PAID
PermitTRAK
$30,413.70
M14-0013 Address: 4716 S 122 ST
Apn: 3347401455 $221.32
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0014 Address: 4920 S 114 ST
Apn: 3348401711 $221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0015 Address: 13049 56 AVE S
Apn: 2172000060 $246.42
MECHANICAL
$236.94
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$157.05
PLAN CHECK FEE
R000.322.102.00.00
$47.39
TECHNOLOGY FEE
$9.48
TECHNOLOGY FEE
R000.322.900.04.00
$9.48
M14-0016 Address: 12055 44 AVE S 1
Apn: 3347400420 $221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0017 Address: 12404 50 PL S
Apn: 0179002265 $233.88
MECHANICAL
$224.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
$44.98
TECHNOLOGY FEE
$9.00
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 8 of 11
Cash Register Receipt
City of Tukwila
Receipt Number
DESCRIPTIONS ACCOUNT QUANTITY PAID
PermitTRAK $30,413.70
M14-0018 Address: 11836 44 AVE S Apn: 3347401015 $246.42
MECHANICAL $236.94
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$157.05
PLAN CHECK FEE
R000.322.102.00.00
$47.39
TECHNOLOGY FEE $9.48
TECHNOLOGY FEE
R000.322.900.04.00
$9.48
M14-0019 Address: 12012 44 AVE S Apn: 3347401060 $221.32
MECHANICAL $212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE $8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0020 Address: 12020 42 AVE S Apn: 3347400290 $221.32
MECHANICAL $212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE $8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0021 Address: 4925 S 125 ST Apn: 0179002840 $246.42
MECHANICAL $236.94
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$157.05
PLAN CHECK FEE
R000.322.102.00.00
$47.39
TECHNOLOGY FEE $9.48
TECHNOLOGY FEE
R000.322.900.04.00
1
$9.48
M14-0022 Address: 1223146 AVE S Apn: 0179000840 $221.32
MECHANICAL $212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 9 of 11
SYSTEMS
DESCRIPTIONS
ACCOUNT QUANTITY PAID
PermitTRAK
$30,413.70
M14-0022 Address: 1223146 AVE S
Apn: 0179000840 $221.32
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
M14-0023 Address: 4702 S 122 ST Apn: 3347401430 $233.88
MECHANICAL
$224.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
$44.98
TECHNOLOGY FEE
$9.00
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
M14-0024 Address: 11608 40TH AVE S
Apn: 7340600140 $233.88
MECHANICAL
$224.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
$44.98
TECHNOLOGY FEE
$9.00
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
M14-0025 Address: 13007 57TH AVE S
Apn: 2137000020 $233.88
MECHANICAL
$224.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
$44.98
TECHNOLOGY FEE
$9.00
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
M14-0026 Address: 12239 46 AVE S
Apn: 0179000830 $221.32
MECHANICAL
$212.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$137.75
PLAN CHECK FEE
R000.322.102.00.00
$42.56
TECHNOLOGY FEE
$8.51
TECHNOLOGY FEE
R000.322.900.04.00
$8.51
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 10 of 11
YSTE/vV;
DESCRIPTIONS
PermitTRAK
I ACCOUNT I QUANTITY
I PAID
$30,413.70
M14-0030 Address: 11664 44 AVE S
Apn: 3347400690
$233.88
MECHANICAL
$224.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$147.40
PLAN CHECK FEE
R000.322.102.00.00
$44.98
TECHNOLOGY FEE
$9.00
TECHNOLOGY FEE
R000.322.900.04.00
$9.00
TOTAL FEES PAID BY RECEIPT: R1222
$30,413.70
Date Paid: Tuesday, February 11, 2014
Paid By: PAMELA K KUEHL
Pay Method: CREDIT CARD 055617
Printed: Tuesday, February 11, 2014 10:49 AM 11 of 11
6300 Southcenter Blvd., #100, Tukwila. WA 98188
Permit Inspection Request Line (206) 431-2451
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
(206) 431-367
ProjecttType
of Inspectidn: n
t___
Address:
�i w
fL
I (4 �'S
Date Called: ___
oLs6I-'"
Special Instructions:
l
Date Wanted: �' `� .a mf
p•
Requester:
Phone No:
(Do2 - Sig -f551`
jf pproved per applicable codes.
Corrections required prior to approval.
COMMENTS:
i
k
(: %J
Inspector:
Date - 14- 2(
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
City of Tukwila
Department of Community Development
January 15, 2014
Sharyn Parker
7277 Perimeter Rd S
Seattle, WA 98108
Jim Haggerton, Mayor
Jack Pace, Director
RE: Correction Letter # A
Mechanical Application Number M14-0005 through M14-0015 and M14-0018 through M14-0026
King County Noise Remediation Program
Dear Sharyn Parker,
This letter is to inform you of corrections that must be addressed before your development permit can be approved. All
correction requests from each department must be addressed at the same time and reflected on your drawings. I have
enclosed comments from the following departments:
BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments.
(GENERAL NOTE)
PLAN SUBMITTALS: Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised
plan sheets shall be the same size sheets as those previously submitted.
1. All mechanical notes calculations, table titles and references refer to either Seattle Residential codes (SRC) or
outdated WAC and WSEC code references. Revise all notes, calculations, table titles and any related references to
show compliance with 2012 International Residential Codes (IRC) as adopted by the City of Tukwila. This also
shall include compliance with the related codes 2012 WSEC, IMC and IBC codes.
Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other
documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be
resubmitted with the appropriate revision block.
In order to better expedite your resubmittal, a Revision Submittal Sheet' must accompany every resubmittal. I have
enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail
or by a messenger service.
If you have any questions, I can be reached at 206-433-7165.
Sincerely,
File No. M14-0005 thru M14-0015 & M14-0018 thru M14-0026
6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
ERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M14-0014
PROJECT NAME: Mori & Wong Residence
SITE ADDRESS: 4920 S. 114th St.
Original Plan Submittal
X Response to Correction Letter # 1
DATE: 02/06/13
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
Building Division
Public Works
Fire Prevention
Structural
Planning Division
Permit Coordinator
n
PRELIMINARY REVIEW:
Not Applicable n
(no approval/review required)
DATE: 02/11/14
Structural Review Required
REVIEWER'S INITIALS: DATE:
n
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
Approved with Conditions
Denied
(corrections entered in Reviews) (ie: Zoning Issues)
DUE DATE: 03/11/14
n
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M14-0014
PROJECT NAME: Mori & Wong Residence
DATE: 01/10/2014
SITE ADDRESS: 4920 S 114 St
X Original Plan Submittal
Response to Correction Letter #
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS: r1 j,(Ame i0�'I�r�
("(9
Building Division go
Public Works
Fire Prevention
Structural
n
Planning Division
Permit Coordinator n
PRELIMINARY REVIEW:
Not Applicable
(no approval/review required)
DATE: 01/14/14
Structural Review Required
REVIEWER'S INITIALS: DATE:
n
APPROVALS OR CORRECTIONS:
DUE DATE: 02/11/14
Approved
Corrections Required
n
Approved with Conditions ❑
Denied
(corrections entered in Reviews) `' (ie: Zoning Issues)
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED: 0 l' 17 ' l,"I
Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: (7PJ
12/18/2013
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Web site: http://www.TukwilaWA.gov
REVISION
SUBMITTAL
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date: January 23rd. 2014
❑ Response to Incomplete Letter #
▪ Response to Correction Letter # 1
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Project Name:
Project Address:
Contact Person:
Summary of Revision:
Mori & Wong Residence
4920 S 114 St
Sharyn Parker
Plan Check/Permit Number: M 14-0014
RECEIVED
CITY OF TUKWILA
FEB 0 6 2014
PERiVIIT CENTER
Phone Number: 206 296-7437
Revised all code references to show compliance with:
2012 Washington State Energy Code, Residential
2012 International Building Code
WAC 51-51 (Washington State Amendments to 2012 IBC)
Obsolete and incorrect references were corrected and marked with a revision cloud.
Code references found to be accurate and compliant with the 2012 codes cited above
were left unchanged and unmarked.
SheetNumber(s): M1.0., M2.0
"Cloud" or highlight all areas of revision including date of revision
Received at the City of Tukwila Permit Center by: /)�tj
Entered in Permits Plus on
W:4Pcrmit Center\Revision Submittal Form - Merge.doc
Revised: May 20I l
G & G SPECIALTY CONTRCTOR? TNC
Page 1 of 2
ashington State Department of
_abor & Industries
G & G SPECIALTY CONTRCTORS INC
Owner or tradesperson
GOODBALLET, JAMES SCOTT
Principals
GOODBALLET, JAMES SCOTT, PRESIDENT
GOODBALLET, TERESA LYNN, SECRETARY
GOODBALLET, CHARLES ELMER, CHIEF
EXECUTIVE OFFICER
WAVY, CHRISTINE, CHIEF OPERATING
OFFICER
Doing business as
G & G SPECIALTY CONTRCTORS INC
WA UBi No.
602 975 812
Parent company
G & G SPECIALTY CONTRCTORS INC
1221 N. Monde! DR
GILBERT, AZ85233
480-921-4079
Business type
Corporation
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor
License specialties
GENERAL
License no.
GGSPEGS919RT
Effective — expiration
12/31 /2009— 12/31/2015
Bond
HARTFORD FIRE INS CO
Bond account no.
59BSBEA9058
Active.
Meets current requirements.
$12,000.00
Received by L&I Effective date
01/03/2011 12/18/2010
Bond history
Insurance
National Union Fire Ins of PA $1,000,000.00
Policy no.
xnd0055800
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602975812&LIC=GGSPEGS919RT&SAW= 05/19/2014
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM ,
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CIRC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
G
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
H WC
HWG
HWR
HWS
LAT
LWG
LWT
MAX
MBH
MCA
MIN
MTG
MFG
NC
NIC
NFPA
NG
NO
N TS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SG
SHT
SM
SO
SP
SPD
SPEC
TDH
TOD
TPD
TSP
TYP
VD
VTR
WB
W/
WAC
WSEC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INTERNATIONAL RESIDENTIAL CODE
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SUPPLY DIFFUSER
SHEET
SHEET METAL
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WASHINGTON ADMINISTRATIVE CODE
WASHINGTON STATE ENERGY CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
OR XX
ABBR
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
ROUND DUCT DIAMETER
X/Y X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
V/// /A -
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MECHANICAL PLANS AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
NTTOR . AL LD 1 ' IF L : DIN ND D , SI
BE • E : NNI ► CO I UC
I
0
•
RD
G • IPM
�•
OT AL OM ' AN
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET 2012 WASHINGTON STATE ENERGY CODE (WSEC) RESIDENTIAL
SECTION 4, 403.2.1 REQUIREMENTS.
C • K • 1 ETR ON RO
AIRTIGHT.
GS 1D R
••
IN
AL 1 AIR
11
RAL • LU PE
TH
GH
11
CTS ALL
6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
THERMOSTATS 4'-0" AFF. UNLESS NOTED OTHERWISE.
9 PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRAKEKVIEVIEWOR
CODE COMPLIANCE
APPROVED
FEB 19 2014
T kwila
ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
10. MAINTAIN 10'-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
12. MAINTAIN 3'-0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
City
SYMBOL
SG—X
XXX
ABBR
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
li DN I DN DUCT OFFSET DOWN IN
FLOW DIRECTION
+ UP 4' UP
=11+
N
VD.
RA/EA
RG
SA
SA
EN-F- RA/EA
SD
0-0
O EN-
+=1>i
�R `-.
EQUIP ID#
NG
ICI
D
0
D"a
DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
CEILING SUPPLY GRILLE
CEILING RETURN GRILLE
EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION — RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
THERMOSTAT
EQUIPMENT LOCATION
MOD MOTOR OPERATED DAMPER
NG NATURAL GAS PIPE
PIPE/DUCT ELBOW DOWN
PIPE/DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
REVISIONS
No changes shalt be made to the scope
Of work without prior approval of
Tukwila Building Division.
NOTE: I"'TriS .173 will require a new plan submittal
.�. .I I. rOlfiM'.1
MECHANICAL/ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
DESCRIPTION
VOLTS
PH
23
26
23
26
N/A
23
26
N/A
BV-1
BLENDING UNIT VENTILATOR
120
1
X
X
X
1,2
—
SWITCHES (ON, TIMER)
120
1
X
X
X
1
REMARKS:
1 — VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 — DISCONNECT SWITCH
BLENDING UNIT VENTILATOR
MARK
CFM
EXTERNAL
STATIC
DIMENSIONS
ELECTRICAL
COMMENTS
WATTS
VOLTS
PHASE
BV-1
195
.5" WG
32"Lx12.25"Wx8.5"H
76
120
1
1, 2, 3
NOTE:
1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER.
2. PROVIDE WITH SPEED CONTROL
3. BASIS OF DESIGN: ALDES AMERICAN
A. OR APPROVED EQUAL.
GRILLE AND DIFFUSER SCHEDULE
MARK
CFM
STATIC
PRESSURE
INLET OR NECK
SIZE
DUCT
CONNECTION
LOCATION
MODEL #
REMARKS
SG-1
195
<.08" WG
8"
8"
CEILING
ALLGRILLE
1, 2, 4
OG-1
120
<.08" WG
7"
7"
WALL
WALL CAP
1, 2, 3, 4
RG-1
25
<.08" WG
4"
4"
CEILING
DECO
1, 2, 4
REMARKS:
1. INSTALL PER MANUFACTURER'S
2 PAINT TO BE COORDINATED WITH
3. PROVIDE WITH BACKDRAFT DAMPER
4. BASIS OF DESIGN: ALDES
A. OR APPROVED EQUAL.
WRITTEN INSTRUCTIONS
TECHNICAL REPRESENTATIVE
AND INSECT SCREEN
5. BASIS OF DESIGN: SHOEMAKER
A. OR APPROVED EQUAL.
6. PROVIDE WITH AN OPPOSED BLADE DAMPER
IRC 2012
RESIDENCE CODE
FLOOR AREA
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
43
3
C
1 M
.0
1. VENTILATION PROVIDED PER 2012 IRC, SECTION M1507, TABLES M1507.3.3(1) AND M1507.3.3(2), AND
WAC CHAPTER 51-51, SECTION M1507
1
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION
MIN VALUE
NOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R-8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR/CEILING
R-8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R-8
1,3
IN CEMENT SLAB OR IN GROUND
R-5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS
MEDIUM NOT INCLUDING FINISHING MATERIALS.
OF THE BASIC INSULATING
WHICH IS LOCATED WITHIN A WALL OR
EXPOSED TO UNCONDITIONED AIR AND
RESIDENTIAL FOR ADDITIONAL
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT
FLOOR/CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE
3. REFER TO 2012 WASHINGTON STATE ENERGY CODE (WSEC)
REQUIREMENTS.
SEPARATE PERMIT
REQUIRED FOR:
Mechanical
Electrical
Plumbing
Gas Piping
City of Tukwila
BUILDING DIVISION
DRAWING NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS
RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW
THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR
EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO
START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING
ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY,
QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT.
REFER TO SECTIONS 011101 AND 028200 FOR REGULATED
MATERIALS ABATEMENT.
VENTILATION SCHEDULE
FILE COPY
Permit No.
Plan review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Field Copy and conditions is acknowledged:
By(/4
Date: 6'-/4 - M
UILD NG ' VIS • N
SET BV-1 SWITCH TO OPERATE VENTILATION UNIT A MINIMUM 2 HOURS OF EVERY 4—HOUR
SEGMENT.
MECHANICAL VENTILATION CALCULATION
PER IRC M1507.3.3
FROM TABLE M1507.3.3(1)
CONTINUOUS VENTILATION SYSTEM AIRFLOW REQUIREMENT:60 CFM
FROM TABLE M1507.3.3(2)
VENTILATION SYSTEM RUN TIME PERCENTAGE IN EACH 4—HOUR SEGMENT: 50%
INTERMITTENT WHOLE -HOUSE MECHANICAL VENTILATION RATE FACTOR: a
REQUIRED VENTILATION RATE: 5Q/2=120 CFM
wpwoxii-
RECEIVED
CITY OF TUKWILA
FEB 0 6 2014
PERMIT CENTER
CORRECTION
LTR#, 1
i
S.M. STEMPER
ARCHITECTS
A Frofeaulonal Malted 1/011118 Company
4000 DELUXE WAY SW
SUITE 200 • SEA!rrLE, WA 98108
(208) 024-2777 FAX (208) 824-2073
THE GREENBUSCH- GROUP, INC
0440•0••••)
ACOus110M._ / NOE0 & MECHANICAL E NG
1800 MEET ACUExsull STREET SUITE 101 SEAmE. W1 NMI
(200) 378-0589 (206) 378-0841 FAX
081003.2543
rt
0
ct
Z
0
Z
W
Z
0
C�
0
Z
z
w
w
0
0
w
w
w
CO
ce
z
W
AIP NUMBER
3-53-0058-047
TUKWILA WASHINGTON
DATE
07/19/2013
ISSUED 100% CD
PROJECT ENGINEER
DT
PROJECT MANAGER
DT
DRAWN
JA
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
EXPIRES: 9/08/2014
CLOSET
BEDROOM
1
O Rwt 251
(E) 22" x 30"
ATTIC ACCESS
PANEL
BEDROOM
2
(E)SG
I
SEE
CHASE, REFER TO
ARCHITECTURAL
TYP ALL
CEILING GRILLES
(E)SG
MEKI
rIro
KITCHEN
BATH
w
(r)
0
LIVING
ROOM
(E)SG
MAIN FLOOR MECHANICAL PLAN
SCALE: 1 /4" = 1'-0"
NORTH
BEDROOM
p 3
Gg--1.
25
CLOSET
LOWER FLOOR MECHANICAL PLAN
SCALE: 1 /4" = 1'-0"
BATH
NORTH
P
MOTOR AND
FILTER ACCESS
RETURN AIR
DUCT
OUTSIDE AIR
DUCT
SUPPLY .AIR DUCT
STRAP TO STRUCTURE
PER MANUFACTURER'S
WRITTEN
INSTRUCTIONS.
BV-1
ACCESS HATCH
SEE
CEILING
NOTES:
1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION.
2. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
3. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCH
SIZE AND LOCATION WITH ARCHITECT.
BV-1 INSTALLATION DETAIL
SCALE: NONE
r-
5
"0
TYP
4"0 DN
TO RG --.-C
SEE
L-
a
111 I1
II.'--- M L
TO TIMER
SWITCH
(E) 22" x 30"
ATTIC ACCESS
PANEL
4"0
8"0
L_t
Lw
ATTIC MECHANICAL PLAN
SCALE: 1 /4" = 1'-0"
FOAM BACKER
ROD, TYP
CAULK, TYP
SHEETMETAL
TRANSITION TO WALL
CAP NECK SIZE
FLEX DUCT
PER PLAN
NOTES:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORDINATE WITH ARCHITECTURAL DETAIL DRAWINGS.
0 DN
i
7
(E)OPENING
11 IN SECOND
J L ROOF
8"0 DN
TO SG-1
b
WLr
irj-
_ J
T
L
NORTH
WALL CAP DETAIL
SCALE: NONE
1
(E)SIDING
SHEET METAL
FLASHING
2X2 BLOCKING
WALL CAP
2X2 BLOCKING
2X2 BLOCKING
SHEETMETAL
TRANSITION TO
DIFFUSER NECK
SIZE
2X BLOCKING
SLEEVE AND
ESCUTCHEON
GRILLE
Lw
1
fi
1
REVIEWED
CODE COMPLIANCE
APPROVED
FEB 19 2QV
City NG D�iS{ON
la
BUILD
PATIO
OVERHANG
DRAWING NOTES:.
1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS
AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW
ANY HAZARDOUS OR NOXIOUS SOURCE PER
WAC 51-51 SECTION M1507.3.6.5.
F RS: AFTER EQUIP ENT D S TEM
CHECK—OUT WORK HAS BEEN COMPLETED AND
PRIOR TO COMMENCEMENT OF TAB WORK,
PERFORM THE FOLLOWING:
A) REPLACE AIR FILTERS IN THE
FURNACE AND/OR BLENDING AIR UNIT
SYSTEM(S) WITH NEW FILTERS.
FLAG NOTES:
BV-1 AND DUCTWORK ROUTED IN ATTIC.
COORDINATE ELECTRICAL AND MAINTENANCE
ACCESS HATCH WITH TECHNICAL
REPRESENTATIVE.
ELECTRICIAN TO PROVIDE PROGRAMMABLE
TIMER SWITCH BY TECHNICAL SPECIFICATIONS
SECTION 260010. AFFIX A LABEL TO THE
CONTROLLER THAT READS "WHOLE HOUSE
VENTILATION (SEE OPERATING INSTRUCTIONS)"
PER WAC 51-51 SECTION M1507.3.2.
COORDINATE FINAL SWITCH LOCATION WITH
HOMEOWNER.
TRANSITION DUCT TO AIR TERMINAL NECK
SIZE IMMEDIATELY BEFORE MAKING FINAL
GRILLE OR DIFFUSER CONNECTION.
PROVIDE CUTTING AND PATCHING AS
REQUIRED TO INSTALL OUTSIDE AIR INLET,
REFER TO ARCHITECTURAL DRAWINGS AND
TECHNICAL SPECIFICATIONS.
INSULATE ALL DUCT AS SCHEDULED. REFER
TO THE MINIMUM DUCT INSULATION THICKNESS
SCHEDULE ON M1.0.
4IHOO �y
DUCT PER PLAN
FIELD FABRICATE
PLENUM BEHIND
CEILING GRILLE
FOAM BACKER ROD
CAULK
2X BLOCKING
FLOOR OR
CEILING JOIST
CEILING
NOTES:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. CEILING SUPPLY INSTALLATION SHOWN, RETURN SIMILAR.
CEILING GRILLE DETAIL
SCALE: NONE
RECEIVED
CITY OF TUKWILA
FEB 0 6 2014
PERMIT CENTER
S.M. STEMPER
ARCHITECTS
A Profennional Limited UJeb1111,7 Comp
4000 DELRIDGE WAY SW
SUITE 200 • SEA'fl'LE, WA 98108
(200) 624-2777 • FAX (200 624-2975
THE GREENBUSCH GROUP, INC
• O•
1900 W 1CAL. Auao vroEO s wEc *WA CN. O WA 91313
13 NG
190D WW1 SINiiT S mE 201 9FA111� r 9l11Y
(200) 378-0549 (200 378-0641 FAX
0810032543
z
w
w
Ct O
Ct
0
Q
Z �
O W
Zet cio
Lu Z
Z �
gu"."
0 ce
U Q
0
Z
Y
Z
W
CO
0
rt
AIP NUMBER
3-53-0058-047
TUKWILA WASHINGTON
DATE
07/19/2013
ISSUED 100% CD
PROJECT ENGINEER
DT
PROJECT MANAGER
DT
DRAWN
JA
MECHANICAL
PLANS
EXPIRES: 9/08/2014