Loading...
HomeMy WebLinkAboutPermit M14-0015 - BURKE & ANDERSON - RENOVATION FOR RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTBURKE & ANDERSON RESIDENCE 13049 56 AVE S M14-OO15 Citv of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No: 2172000060 Permit Number: M14-0015 Address: 13049 56 AVE S Issue Date: 5/19/2014 Permit Expires On: 11/15/2014 Project Name: BURKE & ANDERSON Owner: Name: ANDERSON JOSEPH BURKE+MARY Address: 13049 56TH AVE S, TUKWILA, WA, 98178 Contact Person: Name: SHARYN PARKER Phone: (206) 296-7437 Address: 7277 PERIMETER RD S , SEATTLE, WA, 98108 Contractor: Name: G & G SPECIALTY CONTRCTORS INC Address: 4633 S 36 ST, PHOENIX, AZ, 85040 License No: GGSPEGS919RT Lender: Name: Address: Phone: (480) 921-4079 Expiration Date: 12/31/2015 DESCRIPTION OF WORK: MECHANICAL RENOVATION OF SINGLE FAMILY HOME REQUIRE FOR PARTICIPATION IN FAA (RANRIP) RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM TO REDUCE NOISE FILTRATION. THIS WORK MAY INCLUDE STAND ALONG BLENDING UNIT VENTILATION SYSTEM WITH ASSOCIATED DUCTING AND/OR VOLUME DAMPER INSTALLATION TO EXISTING FURNACE WITH EXISTING DUCTING Valuation of Work: $3,635.00 Type of Work: Fuel type: Fees Collected: $246.42 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer Distric: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2012 2012 Permit Center Authorized Signature: j 1It J'YVV� Date: CCI (C l -J I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: "/C a / & gfriAgZ Date: 5-4- / This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 11: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKW A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use only) ('H0`V-f MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 2172000060 Site Address: 13049 56th Ave. S. Suite Number: Floor: Tenant Name: PROPERTY OWNER Name: Vo(kt,C 41 ,:e.iirc.`�/� ` ,^ Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: Sharyn Parker Address: 7277 Perimeter Road South City: Seattle State: WA Zip: 98106 Phone: (206) 296-7437 Fax: (206) 269-7315 Email: Sharyn.Parker@kingcounty.gov New Tenant: ❑ Yes m „No MECHANICAL CONTRACTOR INFORMATION Company Name: not yet awarded Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ 3,635 Describe the scope of work in detail: Mechanical renovation of single-family home required for participation in FAA (RANRIP) Residential Aircraft Noise Remedy Improvements Program to reduce noise infiltration. This work may include: stand-alone blending unit ventilation system with associated ducting and / or volume damper installation to existing furnace with existing ducting. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement ❑ Fuel Type: Electric ❑ Gas Other: H:\Applications\Forms-Applications On Line\201 I Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 201 I bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <1 OOk btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system 1 Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE UTHORIZED AGENT: Signature: Date: q CMAk 9'9 k t Print Name: imothy Fe son Day Telephone: (206) 624-2777 Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 D14-0006 Address: 4928 S 113 ST Apn: 3348401741 $1,337.30 DEVELOPMENT $1,298.10 PERMIT FEE R000.322.100.00.00 $784.00 PLAN CHECK FEE R000.345.830.00.00 $509.60 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $39.20 TECHNOLOGY FEE R000.322.900.04.00 $39.20 D14-0007 Address: 4230 S 116 ST Apn: 3347400050 $1,103.22 DEVELOPMENT $1,070.90 PERMIT FEE R000.322.100.00.00 $646.30 PLAN CHECK FEE R000.345.830.00.00 $420.10 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $32.32 TECHNOLOGY FEE R000.322.900.04.00 $32.32 D14-0008 Address: 4811 S 124 ST Apn: 0179003115 $1,103.22 DEVELOPMENT $1,070.90 PERMIT FEE R000.322.100.00.00 $646.30 PLAN CHECK FEE R000.345.830.00.00 $420.10 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $32.32 TECHNOLOGY FEE R000.322.900.04.00 $32.32 D14-0009 Address: 12216 47 AVE S Apn: 0179001140 $924.38 DEVELOPMENT $897.32 PERMIT FEE R000.322.100.00.00 $541.10 PLAN CHECK FEE R000.345.830.00.00 $351.72 WASHINGTON STATE SURCHARGE 8640.237.114 $4.50 TECHNOLOGY FEE $27.06 TECHNOLOGY FEE R000.322.900.04.00 $27.06 D14-0010 Address: 5702 5 PAMELA DR Apn: 7344000020 $1,077.20 DEVELOPMENT $1,045.65 PERMIT FEE R000.322.100.00.00 $631.00 PLAN CHECK FEE R000.345.830.00.00 $410.15 WASHINGTON STATE SURCHARGE 8640.237.114 $4.50 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 1 of 11 Aim A SYSTEMS DESCRIPTIONS I ACCOUNT I QUANTITY ( PAID PermitTRAK $30,413.70 D14-0010 Address: 5702 S PAMELA DR Apn: 7344000020 $1,077.20 TECHNOLOGY FEE $31.55 TECHNOLOGY FEE R000.322.900.04.00 $31.55 D14-0011 Address: 4702 S 124 ST Apn: 0179001210 $857.74 DEVELOPMENT $832.64 PERMIT FEE R000.322.100.00.00 $501.90 PLAN CHECK FEE R000.345.830.00.00 $326.24 WASHINGTON STATE SURCHARGE 6640.237.114 $4.50 TECHNOLOGY FEE $25.10 TECHNOLOGY FEE R000.322.900.04.00 $25.10 D14-0012 Address: 12212 46 AVE S Apn: 0179000910 $1,129.22 DEVELOPMENT $1,096.14 PERMIT FEE R000.322.100.00.00 $661.60 PLAN CHECK FEE R000.345.830.00.00 $430.04 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $33.08 TECHNOLOGY FEE R000.322.900.04.00 $33.08 D14-0013 Address: 11870 44 PL S Apn: 3347400790 $957.70 DEVELOPMENT $929.66 PERMIT FEE R000.322.100.00.00 $560.70 PLAN CHECK FEE R000.345.830.00.00 $364.46 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $28.04 TECHNOLOGY FEE R000.322.900.04.00 $28.04 D14-0014 Address: 4716 S 122 ST Apn: 3347401455 $1,103.22 DEVELOPMENT $1,070.90 PERMIT FEE R000.322.100.00.00 $646.30 PLAN CHECK FEE R000.345.830.00.00 $420.10 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $32.32 TECHNOLOGY FEE R000.322.900.04.00 $32.32 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 2 of 11 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT QUANTITY PAID $30,413.70 D14-0015 Address: 4920 S 114 ST Apn: 3348401711 $1,077.20 DEVELOPMENT $1,045.65 PERMIT FEE R000.322.100.00.00 $631.00 PLAN CHECK FEE R000.345.830.00.00 $410.15 WASHINGTON STATE SURCHARGE • B640.237.114 $4.50 TECHNOLOGY FEE $31.55 TECHNOLOGY FEE R000.322.900.04.00 $31.55 D14-0016 Address: 13049 56 AVE S Apn: 2172000060 $1,285.28 DEVELOPMENT $1,247.61 PERMIT FEE R000.322.100.00.00 $753.40 PLAN CHECK FEE R000.345.830.00.00 $489.71 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $37.67 TECHNOLOGY FEE R000.322.900.04.00 $37.67 D14-0017 Address: 12055 44 AVE S 1 Apn: 3347400420 $657.82 DEVELOPMENT $638.60 PERMIT FEE R000.322.100.00.00 $384.30 PLAN CHECK FEE R000.345.830.00.00 $249.80 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $19.22 TECHNOLOGY FEE R000.322.900.04.00 $19.22 D14-0018 Address: 12404 50 PL S Apn: 0179002265 $1,207.26 DEVELOPMENT $1,171.88 PERMIT FEE R000.322.100.00.00 $707.50 PLAN CHECK FEE R000.345.830.00.00 $459.88 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $35.38 TECHNOLOGY FEE R000.322.900.04.00 $35.38 D14-0019 Address: 11836 44 AVE S Apn: 3347401015 $1,363.32 DEVELOPMENT $1,323.35 PERMIT FEE R000.322.100.00.00 $799.30 PLAN CHECK FEE R000.345.830.00.00 $519.55 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 3 of 11 SYSTEMS DESCRIPTIONS I ACCOUNT I QUANTITY I PAID PermitTRAK $30,413.70 D14-0019 Address: 11836 44 AVE S Apn: 3347401015 $1,363.32 TECHNOLOGY FEE $39.97 TECHNOLOGY FEE R000.322.900.04.00 $39.97 D14-0020 Address: 12012 44 AVE S Apn: 3347401060 $857.74 DEVELOPMENT $832.64 PERMIT FEE R000.322.100.00.00 $501.90 PLAN CHECK FEE R000.345.830.00.00 $326.24 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $25.10 TECHNOLOGY FEE R000.322.900.04.00 $25.10 D14-0021 Address: 12020 42 AVE S Apn: 3347400290 $1,493.36 DEVELOPMENT $1,449.57 PERMIT FEE R000.322.100.00.00 $875.80 PLAN CHECK FEE R000.345.830.00.00 $569.27 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $43.79 TECHNOLOGY FEE R000.322.900.04.00 $43.79 D14-0022 Address: 4925 S 125 ST Apn: 0179002840 $1,259.28 DEVELOPMENT $1,222.37 PERMIT FEE R000.322.100.00.00 $738.10 PLAN CHECK FEE R000.345.830.00.00 $479.77 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $36,91 TECHNOLOGY FEE R000.322.900.04.00 $36.91 D14-0023 Address: 1223146 AVE S Apn: 0179000840 $857.74 DEVELOPMENT $832.64 PERMIT FEE R000.322.100.00.00 $501.90 PLAN CHECK FEE R000.345.830.00.00 $326.24 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $25.10 TECHNOLOGY FEE R000.322.900.04.00 $25.10 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 4 of 11 TEt Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $30,413.70 D14-0024 Address: 4702 S 122 ST Apn: 3347401430 $924.38 DEVELOPMENT $897.32 PERMIT FEE R000.322.100.00.00 $541.10 PLAN CHECK FEE R000.345.830.00.00 $351.72 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $27.06 TECHNOLOGY FEE R000.322.900.04.00 $27.06 D14-0025 Address: 11608 40TH AVE 5 Apn: 7340600140 $1,545.38 DEVELOPMENT $1,500.06 PERMIT FEE R000.322.100.00.00 $906.40 PLAN CHECK FEE R000.345.830.00.00 $589.16 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $45.32 TECHNOLOGY FEE R000.322.900.04.00 $45.32 D14-0026 Address: 13007 57TH AVE S Apn: 2137000020 $791.10 DEVELOPMENT $767.96 PERMIT FEE R000.322.100.00.00 $462.70 PLAN CHECK FEE R000.345.830.00.00 $300.76 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $23.14 TECHNOLOGY FEE R000.322.900.04.00 $23.14 D14-0027 Address: 12239 46 AVE S Apn: 0179000830 $857.74 DEVELOPMENT $832.64 PERMIT FEE R000.322.100.00.00 $501.90 PLAN CHECK FEE R000.345.830.00.00 $326.24 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $25.10 TECHNOLOGY FEE R000.322.900.04.00 $25.10 D14-0040 Address: 11664 44 AVE S Apn: 3347400690 $1,389.32 DEVELOPMENT $1,348.59 PERMIT FEE R000.322.100.00.00 $814.60 PLAN CHECK FEE R000.345.830.00.00 $529.49 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 5 of 11 SYSTEMS Cash Register Receipt City of Tukwila Receipt Number DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 D14-0040 Address: 11664 44 AVE S Apn: 3347400690 $1,389.32 TECHNOLOGY FEE $40.73 TECHNOLOGY FEE R000.322.900.04.00 $40.73 M14-0005 Address: 4928 S 113 ST Apn: 3348401741 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9,00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 M14-0006 Address: 4230 S 116 ST Apn: 3347400050 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0007 Address: 4811 S 124 ST Apn: 0179003115 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102:00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0008 Address: 12216 47 AVE S Apn: 0179001140 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 6 of 11 toii 1 #fl SYSTEMS DESCRIPTIONS PermitTRAK I ACCOUNT I QUANTITY I PAID $30,413.70 M14-0009 Address: 5702 S PAMELA DR Apn: 7344000020 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 M14-0010 Address: 4702 S 124 ST Apn: 0179001210 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0011 Address: 4928 S 113 ST Apn: 3348401741 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0012 Address: 11870 44 PL S Apn: 3347400790 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0013 Address: 4716 S 122 ST Apn: 3347401455 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 7 of 11 ; YS Tf. M DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $30,413.70 M14-0013 Address: 4716 S 122 ST Apn: 3347401455 $221.32 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0014 Address: 4920 S 114 ST Apn: 3348401711 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 - $8.51 M14-0015 Address: 13049 56 AVE S Apn: 2172000060 $246.42 MECHANICAL $236.94 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $157.05 PLAN CHECK FEE R000.322.102.00.00 $47.39 TECHNOLOGY FEE $9.48 TECHNOLOGY FEE R000.322.900.04.00 $9.48 M14-0016 Address: 12055 44 AVE S 1 Apn: 3347400420 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0017 Address: 12404 50 PL S Apn: 0179002265 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 8 of 11 API PI i?EMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,413.70 M14-0018 Address: 11836 44 AVE S Apn: 3347401015 $246.42 MECHANICAL $236.94 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $157.05 PLAN CHECK FEE R000.322.102.00.00 $47.39 TECHNOLOGY FEE $9.48 TECHNOLOGY FEE R000.322.900.04.00 $9.48 M14-0019 Address: 12012 44 AVE S Apn: 3347401060 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0020 Address: 12020 42 AVE S Apn: 3347400290 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0021 Address: 4925 S 125 ST Apn: 0179002840 $246.42 MECHANICAL $236.94 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $157.05 PLAN CHECK FEE R000.322.102.00.00 $47.39 TECHNOLOGY FEE $9.48 TECHNOLOGY FEE R000.322.900.04.00 $9.48 M14-0022 Address: 1223146 AVE S Apn: 0179000840 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 9 of 11 ArrffiNIPI SYSTEMS DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $30,413.70 M14-0022 Address: 1223146 AVE S Apn: 0179000840 $221.32 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 M14-0023 Address: 4702 S 122 ST Apn: 3347401430 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 M14-0024 Address: 11608 40TH AVE S Apn: 7340600140 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 M14-0025 Address: 13007 57TH AVE S Apn: 2137000020 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 M14-0026 Address: 12239 46 AVE S Apn: 0179000830 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE R000.322.900.04.00 $8.51 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 10 of 11 Y57[ DESCRIPTIONS PermitTRAK I ACCOUNT I QUANTITY I PAID $30,413.70 M14-0030 Address: 11664 44 AVE S Apn: 3347400690 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE R000.322.900.04.00 $9.00 TOTAL FEES PAID BY RECEIPT: R1222 $30,413.70 Date Paid: Tuesday, February 11, 2014 Paid By: PAMELA K KUEHL Pay Method: CREDIT CARD 055617 Printed: Tuesday, February 11, 2014 10:49 AM 11 of 11 INSPECTION NO. INSPECTION RECORD Retain a copy with permit MI4.00IS. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 Project: KJ r i7I<f.SJ1�/ Type of Inspec ion: r e f I. f, ,V A !. Address: t 6049 i``> 5( AVe Date Called: I .��s Special Instructions: z,... Date Wanted: Fs-' f ! 4 ap:.mn. Requester: v i Phone No: ir ry, 0 S J C1 --f) ©Approved per applicable codes. Corrections required prior to approval. COMMENTS: ti Inspector: r REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: `p �J � 1 City of Tukwila Department of Community Development January 15, 2014 Sharyn Parker 7277 Perimeter Rd S Seattle, WA 98108 Jim Haggerton, Mayor Jack Pace, Director RE: Correction Letter # I. Mechanical Application Number M14-0005 through M14-0015 and M14-0018 through M14-0026 King County Noise Remediation Program Dear Sharyn Parker, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. (GENERAL NOTE) PLAN SUBMITTALS: Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted. 1. All mechanical notes calculations, table titles and references refer to either Seattle Residential codes (SRC) or outdated WAC and WSEC code references. Revise all notes, calculations, table titles and any related references to show compliance with 2012 International Residential Codes (IRC) as adopted by the City of Tukwila. This also shall include compliance with the related codes 2012 WSEC, IMC and IBC codes. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made inperson and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-433-7165. File No. M14-0005 thru M14-0015 & M14-0018 thru M14-0026 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 rERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0015 DATE: 02/06/13 PROJECT NAME: Anderson Residence SITE ADDRESS: 13049 56th Ave S Original Plan Submittal X Response to Correction Letter # 1 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: c,a14� ] Building Division J Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 02/11/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 03/11/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0015 PROJECT NAME: Anderson Residence DATE: 01/10/2014 SITE ADDRESS: 13049 56 Ave S X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: �., O I • 11 Building Division : Public Works Fire Prevention Structural n Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 01/14/14 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved [ Approved with Conditions Corrections Required Denied (corrections entered in Review) \ (ie: Zoning Issues) DUE DATE: 02/11/14 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: O 1 ` 1 ` I `M Departments issued corrections: Bldg] Fire ❑ Ping ❑ PW ❑ Staff Initials:. 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: January 23rd, 2014 Plan Check/Permit Number: M 14-0015 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 111 Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Anderson Residence Project Address: 13049 56 Ave S RECEIVED CITY OF TUKWILA FEB 06 2014 PERMIT CENTER Contact Person: Sharyn Parker Phone Number: 206 296-7437 Summary of Revision: Revised all code references to show.compliance with: 2012 Washington State Energy Code, Residential 2012 International Building Code WAC 51-51 (Washington State Amendments to 2012 IBC) Obsolete and incorrect references were corrected and marked with a revision cloud. Code references found to be accurate and compliant with the 2012 codes cited above were left unchanged and unmarked. Sheet Number(s): M 1.0., M2.0 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on W:1Pcrmit Center\Revision submittal Form - Merge.doc Revised: May 20l 1 G & G SPECIALTY CONTRCTOR° TNC Page 1 of 2 Washington State Deparintent of Labor & Industries G & G SPECIALTY CONTRCTORS INC Owner or tradesperson GOODBALLET, JAMES SCOTT Principals GOODBALLET, JAMES SCOTT, PRESIDENT GOODBALLET, TERESA LYNN, SECRETARY GOODBALLET, CHARLES ELMER, CHIEF EXECUTIVE OFFICER WAVY, CHRISTINE, CHIEF OPERATING OFFICER Doing business as G & G SPECIALTY CONTRCTORS INC WA UBI No. 602 975 812 Parent company G & G SPECIALTY CONTRCTORS INC 1221 N. Monde! DR GILBERT, AZ85233 480-921-4079 Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. GGSPEGS919RT Effective — expiration 12/31 /2009-12/31 /2015 Bond HARTFORD FIRE INS CO Bond account no. 59BSBEA9058 $12,000.00 Received by L&I Effective date 01/03/2011 12/18/2010 Bond history Insurance National Union Fire Ins of PA $1,000,000.00 Policy no. xnd0055800 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602975812&LIC=GGSPEGS919RT&SAW= 05/19/2014 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM GFT GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO N TS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SG SHT SM SO SP SPD SPEC TDH TOD TPD TSP TYP V VD VTR W WB W/ WAC WSEC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INTERNATIONAL RESIDENTIAL CODE LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SUPPLY DIFFUSER SHEET SHEET METAL SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WASHINGTON ADMINISTRATIVE CODE WASHINGTON STATE ENERGY CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL ABBR DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW OR CLX EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X/Y — X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION W,////,//A EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.1 MECHANICAL DETAILS M2.0 MECHANICAL PLANS GENERAL NOTES SYMBOL SG-X XXX S ABBR DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DN I DN DUCT OFFSET DOWN IN FLOW DIRECTION UP } OSIESEIZZIO 0 -4 O Or - EQUIP ID R• NG ICI • 0 A UP DUCT OFFSET UP IN FLOW DIRECTION RA/EA RG SA SA RA/EA SD DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR. TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE/DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT REVISIONS No changes shall be made too al ofe of work without prior app Tukwila Building Division. NOTE: yiincludeiadddo al plan rre a new eview fees. lan submittal and may 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE. SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. NT' . TOR .AL LD 'IFY L : DIN ND 1 D SIBE • E NNI► CO 1 UC I• 0 RD G • IPM •• OT AL OM AN 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET 2012 WASHINGTON STATE ENERGY CODE (WSEC) RESIDENTIAL SECTION 4, 403.2.1 REQUIREMENTS. C •'K 'ETR ON RO W P TI• C GS "D R •• IN AL AIR •1 iRAL •LU!1 PE AT TH GH •• CTS ALL AIRTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 4'-0" AFF. UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 10'-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 3'-0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION DESCRIPTION VOLTS PH 23 26 23 26 N/A 23 26 N/A BV-1 BLENDING UNIT VENTILATOR 120 1 X X X 1,2 - MOTOR OPERATED DAMPER (2) 24 1 X X X - 1,2 - THERMOSTAT (2) 120/24 1 X X X 1 - SWITCHES (ON, TIMER) 120 1 X X X 1 NOTES: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK CFM EXTERNAL STATIC DIMENSIONS ELECTRICAL COMMENTS WATTS VOLTS PHASE BV-1 110 .5" WG 32"Lx12.25"Wx8.5"H 76 120 1 1, 2, 3 NOTE: 1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF DESIGN: ALDES AMERICAN A. OR APPROVED EQUAL. WALL CAP SCHEDULE MARK LOCATION CFM AIR VELOCITY FPM STATIC PRESSURE SIZE LOCATION REMARKS SEPARATE PE REQUIRED IRC 2012 RESIDENCE CODE FLOOR AREA 0. BEDROOMS 0 ' REQUIRED VENTILATION' VENTILATION PROVIDED NOTES 0810.03.2544 FURNACE 1013 1 0810.03.2544 BV-1 RLE AD DFUECEUE l TTC ILT OEK DC AK CM PESRIE CNETOOAIN MDL # RMRS G1 10 <0" W" WLLGIL, 2O-0 <0" W" 6AL WLA, 2R-5 <0" W" 4AL DC, 2RMRS . ISAL PR MNFCUE'RTENTUTOS 2 PIT TE CODNTD WTEHIAERSNAIE 3RVDIH BCDAT DMENNET SRE . BSS OEINLE --\"•,r . OPRVD EUL 350 2 90 CFM 120 CFM 1 1 1. VENTILATION PROVIDED PER 2012 IRC, SECTION M1507, TABLES M1507.3.3(1) AND M1507.3.3(2), AND WAC CHAPTER 51-51, SECTION M1507 0 DUCT LOCATION MIN VALUE NOTES ON ROOF OR ON EXTERIOR OF BUILDING R-8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR/CEILING WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R-8 R-8 1,2,3 1,3 IN CEMENT SLAB OR IN GROUND R-5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR/CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO UNCONDITIONED AIR AND • 3. REFER TO 2012 WASHINGTON STATE ENERGY CODE (WSEC) RESIDENTIAL FOR ADDITIONAL REQUIREMENTS. POR: RMIT al City of Tukwila UILDING DIVISION DRAWING NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 011101 AND 028200 FOR REGULATED MATERIALS ABATEMENT. 2. 1BREVIEwc xF©R CODE COMP DANCE APPROVED FEB 19 $1�4 T Ila City of BUILDING ISION LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED TO EXISTING EXTERIOR SIDING AND WINDOW TRIM PAINT. FELE COPS Permit No. M `t-k — 00 t Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions acknowledged: VENTILATION SCHEDULE By Date: 5—/1- /V City Of Tukwila BUILDING DIVISION SET BV-1 SWITCH TO OPERATE VENTILATION UNIT A MINIMUM 2 HOURS OF EVERY 4-HOUR SEGMENT. SET THERMOSTAT TO 'OPERATE FURNACE FAN FOR VENTILATION A MINIMUM 2 HOURS OF EVERY 4-HOUR SEGMENT. IS MECHANICAL VENTILATION CALCULATION PER IRC M1507.3.3 FROM TABLE M1507.33(1) CONTINUOUS VENTILATION SYSTEM AIRFLOW REQUIREMENT:45 CFM FROM TABLE M1507.3.3(2) VENTILATION SYSTEM RUN TIME PERCENTAGE IN EACH 4-HOUR SEGMENT: 50% INTERMITTENT WHOLE -HOUSE MECHANICAL VENTILATION RATE FACTOR: 2 REQUIRED VENTILATION RATE: 5/2=90 CFM RECEIVED FE: 16 PERMIT CENTER S.M. STEMPER ARCHITECTS A F9roramdonai Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEAMS, WA 98106 (208) 624-2777 • FAX (206) 824-2073 THE GREENBUSCH GROUP, INC 10 VW SIT sum 201 MILE, WA 01119 (200) 370-0509 (200) 378-0041 FAX 081003,2544 0 a Q z 0 F— LU z 0 0 0 z i°- 0 cL 0 LU LU LU AIP NUMBER 3-53-0058-047 TUKWILA WASHINGTON DATE 07/19/2013 ISSUED 1Q0% CD PROJECT ENGINEER DT PROJECT MANAGER DT DRAWN JA LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX CORRECTKN LTR# EXPIRES: 9/08/2014 1' PATIO WC-1 60 SEE CRAWL SPACE L UTILIT 8/4 TRANSITION TO 6" ROUND DUCT ROUTE UNDER STAIRS AND UP INTO JOISTS 3 TYP LOWER FLOOR MECHANICAL PLAN SCALE: 1/4" = 1'-0" LOWER MAIN KEY TO VENTILATION ZONES SCALE: NONE FUR NORTH NORTH r -r- T r L'- J� ATTIC (E)SG CLOSET (E)SG BATH t" EG BEDROOM 1 (E)RG (E) 18" x 24 ATTIC ACCESS PANEL DINING ROOM .1 ILJ KITCHEN (E)SG LIVING ROOM (E)SG PATIO MAIN FLOOR MECHANICAL PLAN SCALE: 1/4" = 1'-0" MOD BV-1 NORTH DRAWING NOTES: RESIDENCE IS PARTIALLY CONDITIONED BY A DUCTED FURNACE SYSTEM. L- 2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51-51 SECTIONS M1507.3.5.3. AND M1507.3.6.5. 3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE AUTOMATIC CONTROL SHALL BE SET TO OPERATE THE WHOLE HOUSE FAN ACCORDING TO THE VENTILATION SCHEDULE ON SHEET M1.0, INDEPENDENT OF CALL FOR HEATING, TO SATISFY WAC 51-51, SECTION M1507.3.2. (CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY -CONSUMING APPLIANCES). COORDINATE FINAL TIME SETTING WITH PROJECT REPRESENTATIVE. 4. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK-OUT WORK HAS BEEN COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE FOLLOWING: A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING AIR UNIT SYSTEM(S) WITH NEW FILTERS. to- fYP 3 4 1St OG-1 60 m Gam-] 25 T Fr= (E) 18" x 24" ATTIC ACCESS PANEL BEDROOM 2 SEE Allk ®Tr ALL WALL GRILLE SEE SG-1 110 25 ]N 6 CLOSET BEDROOM 3 TYP 1 1 J ATTIC MECHANICAL PLAN SCALE: 1/4" = 1'-0" FLAG NOTES: NORTH CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. REFER TO C D: G D S - IC • S REMOVE THE EXISTING THERMOSTAT AND PROVIDE 2012 WSEC RESIDENTIAL SECTION R403 COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51-51 SECTION M1507.3.2. INS ATE L D AS CHEDU ED. FER 0 TH MINI 1 DU INSULATION THICKNESS SCHEDULE ON M1.0. BV-1 AND DUCTWORK ROUTED IN ATTIC. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCH WITH TECHNICAL REPRESENTATIVE. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 260010. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51-51 SECTION M1507.3.2. COORDINATE FINAL SWITCH LOCATION WITH HOMEOWNER. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET, REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. tit 00 I s REVIEWED FOR CODE COMPLIANCE APPROVED FEB 19 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 0 6 2014 PERMIT CENTER S.M. STEMPER ARCHITECTS A Protet4loskal Limited U bthtlr Company 4000 DELRIDGE WAY SW SUITE 200 SEATTLE, WA 98106 (200) 024-2777 FAX (200) 024-2973 THE GREENBUSCH GROUP, INC 411644 •) .6 41 ) 1900 VEST IL_ AY_ sroEEErD s AwtS a201 sAORoE..11A 90119 (200) 370-0550 (200) 370-0041 FAX 0810.03.2544 ce 0 eL ce 0 ee KING COUNTY H z w w 0 d 0 w w te cn O z U Q J Q H Z W. W ce AIP NUMBER 3-53-0058-047 z 0 0 z DATE 07/19/2013 ISSUED 100% CD PROJECT ENGINEER DT PROJECT MANAGER DT DRAWN JA MECHANICAL PLANS EXPIRES: 9/08/2014 (E)JOISTS (E)SUPPLY FURNACE FLOOR (E)RETURN VOLUME DAMPER FOR EXISTING RETURN DUCT, FIELD VERIFY SIZE PRIOR TO ORDERING MOD, INTERLOCK TO FURNACE POC OUTSIDE AIR DUCT, SIZE AND RUTE PER PLAN. OUTSIDE AIR TO FURNACE ELEVATION L:1) SCALE: NONE FOAM BACKER ROD, TYP CAULK, TYP SHEETMETAL TRANSITION TO WALL CAP NECK SIZE FLEX DUCT PER PLAN NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL DETAIL DRAWINGS. ®-r wALL CAP DETAIL SCALE: NONE (E)SIDING SHEET METAL FLASHING 2X2 BLOCKING WALL CAP 2X2 BLOCKING 2X2 BLOCKING MOTOR AND FILTER ACCESS SUPPLY AIR DUCT/ A A 1%1 V V CAULK OUTSIDE AIR DUCT STRAP TO STRUCTURE PER MANUFACTURER'S WRITTEN INSTRUCTIONS. ATTIC RETURN AIR DUCT CEILING NOTES: 1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 2. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 3. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCH SIZE AND LOCATION WITH ARCHITECT. SHEETMETAL TRANSITION TO GRILLE NECK SIZE DUCT PER PLAN 2X BLOCKING 2X BLOCKING FOAM BACKER ROD WALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. WALL SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. WALL GRILLE DETAIL SCALE: NONE (E)SIDING SHEET METAL FLASHING 2X2 BLOCKING WALL CAP 2X2 BLOCKING 2X BLOCKING, TYP SLEEVE AND ESCUTCHEON HARD DUCT PER PLAN JOIST CAULK, TYP FOAM BACKER ROD, TYP NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL DETAIL DRAWINGS. WALL CAP DETAIL SCALE: NONE FLAG NOTES: FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4 FEET OF FURNACE RETURN INLET PER WAC 51-51 M1507.3.5.1. CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING FURNACE RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR BALANCING THE OUTSIDE/RETURN AIR TO PROVIDE THE SCHEDULED VOLUME OF OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR TO ORDERING. IF A VOLUME DAMPER EXISTS IN THIS LOCATION, IT MAY BE REUSED. REVIEWED CODE COMPLIANCE APPROVED FEB 19 2014 City of Tukwila BUILDING DIVISION t4114-0-0015 RECEIVED CITY OF TUKWILA FEB 0 6 21 Puma CENTER S.M. STEMPER ARCHITECTS 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (200) 624-2777 • FAX (206) 024-2973 THE GREENBUSCH GROUP, INC )))••••••••• rainsr ea& do stiturwarit 1362NEERING (206) 375-0569 (206)376-06111111a 0810,03.2544 0 0 0 0 0 z RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS AIP NUMBER 3-53-0058-047 DATE 07/19/2013 07/19/2013 ISSUED 100% CD PROJECT ENGINEER DT PROJECT MANAGER DT DRAWN JA MECHANICAL DETAILS EXPIRES: 9/08/2014