Permit M14-0050 - BOEING #13-01 - AIR CONDITIONING UNIT
BOEING #13-01 10002 EAST MARGINAL WY S M14-0050 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0003400021 Permit Number: 10002 E MARGINAL WAY S BLDG 13- Issue Date: 01 BOEING #13-01 Permit Expires On: M 14-0050 3/4/2014 8/31/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BOEING COMPANY THE PO BOX 3707 M/C 20-00 PROPERTY TAX DEPT, SEATTLE, WA, 98124 KEN PINCHIFF 650 S LUCILE ST, SEATTLE, WA, 98108 PINCHIFF MECHANICAL LLC 91 S JACKSON, UNIT 4339 , SEATTLE, WA, 98194 PINCHML876PG 1,, Phone: (206) 643-2046 Phone: (206) 643-2046 Expiration Date: DESCRIPTION OF WORK: FURNISH AND INSTALL ONE 3 TON SPLIT SYSTEM AC UNIT INCLUDING DUCTWORK, PIPING AND CONTROLS FOR NEW SERVER ROOM Valuation of Work: $13,500.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $376.54 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer Distric: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: t�� Date: S-±)` This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKWI Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.Tukw ilaW A.gov Mechanical Permit No. Project No. Date Application Accepted: fAt —CDSO Date Application Expires: 9-c 1 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION WOO King Co Assessor's Tax No.: Site Address:E. MAAG) 4AL 1n1AY S . Suite Numbereat, 13 01 Floor: Tenant Name: 130E Jk1 Cr PROPERTY OWNER Name: I 130611J1,- CO. Address: g o 3o) 3'70-7 1� City: S State: (A).4 Zip:19I ,2j CONTACT PERSON — person receiving all project communication Name: Address: 65° S_ LuciLE-: .si', City: 5 � State: ii4� Zip:C1B 1 OS Phone: 26, ,1.�3_ 2o4 6 Fax: Email: — ke4P j)KG ,-f? eC)Aill Ciii-eon New Tenant: ❑ Yes MECHANICAL CONTRACTOR INFORMATION Company Name: P)KICNIFF MCI1P0.I,C4L LLL Address: 6, 5o .S. Lt)CILE.ST City: S6, d� State: wA Zip:plg'a g Phone: Fax: - II I Fax: 261, - 7 7- )b gt7 Contr Reg No.:p1s.)`8ms76pG Exp Datel0/71 I s Tukwila Business License No.: 040 63,175 Valuation of project (contractor's bid price): $ 13 50O • Describe the scope of work in detail: Flak413 A+.49 ) anA ur ONE 3 1710.1 £ 'UT SNiSM-1 C Ukm-r INc t.vD)tJ/,. 17Ucj tAial+c.K- , 'iP»..►� /NAL) rpr\I )2.Di S I�i'ti kJ E) Sen-\i 01. 1124101,1 Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ Fuel Type: Electric Gas ❑ Other: H:Wpplications'Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type I Qty Furnace <100k btu Furnace > l 00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm I Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN R OR A,UT 1 RIZED NT: Signature: ( Date: 2.%29l )1-1 Print Name: Kehl/4 }i Pink H) FF Mailing Address: 6SO S- t-U Cl IZ .3T- Day Telephone: 26 o - 6H.?20q sevrme w.4. q iD$ City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11. docx Revised August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY I PAID $376.54 M14-0050 Address: 10002 E MARGINAL WAY S BLDG 13-01 Apn: 0003400021 $376.54 MECHANICAL $362.06 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $257.15 PLAN CHECK FEE R000.322.102.00.00 $72.41 TECHNOLOGY FEE $14♦48 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R1304 R000.322.900.04.00 $14.48 $376.54 Date Paid: Monday, February 24, 2014 Paid By: KEN PINCHIFF PINCHIFF MECHANIC Pay Method: CREDIT CARD 114292 Printed: Monday, February 24, 2014 9:29 AM 1 of 1 SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit AAS# - o PERMIT NO. CITY OF TUKWILA BUILDING DIVISION v' ` 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project. L.50<-4 6 !3 -0 l Type of inspection: /view . ,J6, �. _LA Address: Date •-Called: jA ,, Special Instructions: .3 v V _.---- Date Wanted: / a.m. p.m. Requester:{ % Approved per applicable codes. O Corrections required prior to approval. COMMENTS: 1crSr4 3 PSG A L' — R. v J6, (+- 1 OP,rAil, i A.0( e P Inspector: Date: Z (o • n REINSPECTION FEE REQUIR O ?t• a to next inspection, fee must be. paid at 6300 Southcenter Blv ., uite 100. Callao schedule reinspectlon. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0050 PROJECT NAME: BOEING #13-01 DATE: 02/24/14 SITE ADDRESS: 10002 EAST MARGINAL WAY S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: A- /tux I Building Division Public Works ire Prevention Structural Planning Division Permit Coordinator n 1 PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 02/25/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 03/25/14 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PINCHIFF MECHANICAL LLC Page 1 of 2 k Washiington State Department of Labor & industries PINCHIFF MECHANICAL LLC Owner or tradesperson PINCHIFF, KENNETH ANDREW Principals PINCHIFF, KENNETH ANDREW EQUINOX BUSNSS LAW GROUP PLLC Doing business as PINCHIFF MECHANICAL LLC WA UBI No. 603 322 609 91 S JACKSON UNIT 4339 SEATTLE, WA98194 206-643-2046 KING County Business type Limited Liability Company Governing persons KENNETHPINCHIFF License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties Heating/Vent/Air-Conditioning and Refrig (HVAC/R) License no. PINCHML876PG Effective — expiration 10/07/2013 —10/07/2015 Bond Great American Ins Co Bond account no. 2208838 Received by L&I 10/07/2013 Insurance Liberty Northwest Ins Corp Policy no. BKS55785886 Received by L&I 10/07/2013 Savings Active. Meets current requirements. $6,000.00 Effective date 11/01/2013 $1 ,000, 000.00 Effective date 10/04/2013 Expiration date 10/04/2014 No savings accounts during the previous 6 year period. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603322609&LIC=PINCHML876PG&SAW= 03/04/2014 LEGEND: '0' DIFFUSER 00 (r) 480 CFM 90 / 16/5 (,0 480 CFM \90 16/5A 525 CFM ° 0 16/5 (0 400 CFM 80 VD 16/16 MEZZ RETURN DUCT SEE DWG 2M11 FOR CONTINUATION ---AStr-AB -2,50 -eFm- 24/24 _R DUCT OPENI rcEro 1150 CFM 30/14 GRILLES FUTURE 03 00 03 NJ 435 CFM 90 G 1150 CFM - T LAD ' • • PSN C/L OF DUCT // SHE'D ROOM / ROOF CHANNELS RUNS TO AVOID IVD 400 CFM \r_i„ 80 )724. 20/14 1 28/14 ,\ So' TRANSPal4TION AISLE 400 CFM T40 CFM MANAGEMENT 2- x12 RFI PAN S (REF) oclo 20/28 20/28 • • VL I E 45Z "SZ VD 141,11 26/11 14/10 F&SD /T7"-'---14/20 SD (TYP 4 PLACES) (TYP 2 LACES) o 0 16/16 ME DUCT SEE IFOR CON T AI •-• - y-- 1M11 M503- TERMINAL. ROO \ AJE OFFICE /1\ 00 c'N (.0 .5C10 Z RETURN DWG 2M11 UATION 24/18 -t: 12C10 ) OTE: FOR XH AU,ST DU2,TS N SHO '="E DWG. 1M11 -15 NE K, TIT -&- 1150 CFM /11-REG: 255CF , 8X8 TITUS- -- MCD tie I 50S CFM ZONE 37/19 VD 48/12 52/19 24/1 8— T ci VD 28x16 DUCT TO 2ND FLR, MEZZ. SEE DWG 2M11 FOR CONTINUATION 750- 28/1 400 CFM, 12x10 SUPPLY GRILLE TITUS 300RS & OPD 2,500 CFM 48/14 RETURN DUCT OPENING (ABOVE CEILING) ZN 0 -360 CFM, 12x10 RETURN GRILLE TITUS 350RL & OPD 16 12 24/19 70/19 -1L- 28/16 ZONE #2 -SL-- 28/16 ZONE #1 Ii ...11.LO. P., 141:10- . MECHANIQL RS)01N 6305 CFM 7205 CFM 5340 CFM TO AIR HANDLER AH2C 1 3 14o dheng-^ of %%to( Ttf- • NOTE: Ravi -- and may REVISIONS shall be made to the scope •!t.hout prior approval of ruliding Division. 1 r,,quire a new plan submittal additional plan review fees. SEPARATE PERMIT REQUIRED FOR: CI Mahan irglectrioal GITIumbing gotras Piping City of Tukwila BUILDING DIVISION 1M11 M505 FIL..AE COPY Permit No. MAO Plan review approval is subject to errors and omissions. t,f of construction documents does not authorize cri any adopted code or ordinance. Receipt b.pproV d Field Copy ancondiq is acknowledged: B Date: SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A UPGRADE 13-01 782758-05 C HARRAH BT&E SECURE DATA CENTER 15448387 M.WONG 12.20.13 8 AST LAB RELOCATION 4110073-00 CH 9,12.01 06.15.05 04.12.06 01.03.13 eliAMIEFEZAKV ® City Of Asicwila BUILDING DIVISION ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN C HARRAH CHECKED ENGINEER DATE 7,26.98 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 6 2014 City of Tukwila BUILDING DIVISION P.O.C. 240 24"0 340 (100 0 AL RETURN GRILL POINT OF CONNECTION FLEXIBLE DUCT. WITH VOLUME DAMPER RECTANGULAR DUCT, FIRST NUMBER INDICATES SIZE FOR SIDE SHOWN. ROUND DUCT, NUMBER INDICATES DIAMETER SUPPLY OUTLET AIR DIFFUSER/REGISTAR/GRILL. REFER TO SHEET MIA. 2-WAY EARTHQUAKE BRACING, SEE 4-WAY EARTHQUAKE BRACING, SEE \OT \J S - M504 (2676-3) - M504 DC01A13A: TORIT SERIES 90 CABINET DUST COLLECTOR RATED TO 2100 CFM ©5.5" H.G. W/5 HP MOTOR, COLLECTING STEEL FILINGS. GAYLORD MODEL #MFC-500A LRAL \C S ALL DUCT DIMENSIONS SHOWN ARE INSIDE CLEAR. 2 ALL DUCTS WHOSE GREATEST DIMENSION IS 30" OR LESS SHALL BE 24 GAUGE GALVENIZED SHEET METAL. 1 ALL DUCTS WHOSE LARGEST DIMENSION IS BETWEEN 31" AND. 54" SHALL BE 22 GAUGE GALVANIZED SHEET METAL. 4. ALL DUCTS WHOSE LARGEST DIMENSION IS BETWEEN 55" AND 84" SHALL BE 20 GAUGE GALVANIZED SHEET METAL, 5. ALL DUCTS WHOSE LARGEST DIMENSION IS GREATER THAN 85" SHALL BE 18 GAUGE GALVANIZED SHEET METAL. 6. REINFORCE DUCTWORK EVERY 4FT, MAX. AND SUPPORT EVERY 8FT, MAX. 8, ALL SUPPLY DUCTS WITHIN THE BUILDING SHALL BE WRAPPED WITH 2"THICK, 1.5 POUND DENSITY FIBER GLASS INSULATION WITH AN ALUMINUM FOIL FACE, REINFORCED WITH FIBER FIBER GLASS YARN MESH AND LAMINATED TO FIRE RESISTANT KRAFT MANVILLE 800 SERIES SPIN GLAS WITH FSK FACE, OR APPROVED EQUAL. 9. DIFFUSER SIZES INDICATED ARE NECK SIZES DIFFUSERS ARE 24"X 24" T-BAR LAY -IN. OVAL \OT Is REMOVE TWO AIR. SUPPLY GRILLES AND SAVE THEM FOR RE -INSTALLATION. SEE DWG. 1M11 FOR THE GRILLES RELOCATION. REMOVE PORTION OF THE DUCTWORK TO INSTALL THE NEW AIR CONDITIONER DUCTWORK. MILI%0001/456 RECEIVED CITY OF TUKWILA FEB 2 4 2014 PERMIT CENTER KEY VIEW SCALE: NONE SUBTITLE HVAC PLAN VIEW CURRENT REVISION 1 544838 7 SYMBOL x DATE 12.20.13 TITLE FREEZER OUTLET SHEET 1M11R AWACS ADVANCED PROJECTS J#140965-00 M.WONG RWS D 13-01 REPAIR 40/45 DAMPERS 2455844 M.WONG MW FOR RWS E FREEZER OUTLET W1155852 SAZAN/GB APPROVED BY DEPT, DATE CHECKED APPROVED APPROVED MECHANCIAL MASTER BUILDING 13-01 COL A-E/8- 1 5 JOB NO. W1155852 COMP NO. D,C, DWG NO. 13-01-1M11R LEGEND: 1M11 03 20/28 co VES J 480 CFM \9 /-\ 480 CFM \9/' 5( 5, 400 CFM 80 1M11 M505 VD 16/16 MEZZ RETURN DUCT SEE DWG 2M11 FOR CONTINUATION 14/10 F&SD (TYP 4 PLACE TERMINAL-R00 1150 CFM 30/14 GRILLES BLUEST 435 CFM 90 ,VD 400 CFM ti ,/80 20/14 1M11 M503 OPENI G E CEILI G) T ;11 :)1\J A1`)1_E 1150 C M PSN C/L OF DUCT RUNS. TO AVID SHEILD ROOM I ROOF CHANNELS I\40 CFM -' MANAGEMENT 2-2 x12 RFI PANELS (REF) -� 80 400 CFM 16/16 ME RETURN DUCT SEE DWG 2M11 FOR CONT UATION 1M11 M500 14 525 CFM TITUS 350FL ALUMINUM W/ OPPOSED BLADE DAMPER, 14X14 (TYP. OF 2) RACK 24/18 ZONE #3 525 CF ALUMIN BLADE (TYP. 0 16/14 FOR SHO VD 37/19 ST DUCTS N DWG. 1M11 1150 CFM •2$/112--RfG, 28x16 DUCT TO 2ND FLR. MEZZ. SEE DWG 2M11 FOR CONTINUATION US 300FL PPOSED 18X12 3—TON CARRIER MODEL FV4CNF003000 W/ PURON REFRIGERANT 10X10 ACCESS DOOR AT BOTTOM •© OF MIXING BOX SECURITY BAR SEE DETAIL 20X20 WEATHERHOOD, WALL COLLAR, BIRDSCREEN, GREENHECK WD SERIES 20X20 BACKDRAFT DAMPER W/ APC SET @ 0.02"WG GREENHECK EM-31 SYM REVISION BY APPROVED DATE SYM REVISION 7.50_. 28A1 FM BEG._ 400 CFM, 12x10 SUPPLY GRILLE TITUS 300RS & OPD Hl.JGHE:'5 360 CFM, 12x10 RETURN GRILLE TITUS 35ORL & OPD 3411 M503 RE-ROUTE THE EXISTING COLD WATER PIPING, SEE DWG. 1. M 111. 13. PURCHASE AND INSTALL THE OUTDOOR AIR CONDITIONER SEE DRAWING RFM61. 2,500 CFM 48/14 RETURN DUCT OPENING (ABOVE CEILING) NEII_iAPJi AL. ROOM 6305 CFM 7205 CFM 5340 CFM I..1JI\1.TION I-DI)RAULIC 105E1_ RE_PAiN TO AIR HANDLER AH2C13 1M11 M505 CAI 14. PURCHASE AND INSTALL THE LIQUID LINE AND VAPOR LINE BETWEEN THE INDOOR AND OUTDOOR UNITS. INSULATE LIQUID LINE W/ 1" & VAPOR LINE WITH 1/2" THICK ARMAFLEX II INSULATION. THE OUTDOOR PORTION OF THE PIPING SHALL HAVE VINYL LACQUER COATING FOR CELLULAR ELASTOMERIC INSULATION, WHITE COLOR. SEE 1M61 FOR PIPING. 15. PURCHASE AND INSTALL THE PRIMARY & SECONDARY CONDENSATE DRAIN FROM THE INDOOR UNIT TO THE LITTLE GIANT PER DWG. 1 M111. NOTE: INSTALL 2" MINIMUM SEPARATE TRAPS FOR THE PRIMARY & SECONDARY DRAINS. SEE 1 M 111 FOR THE PIPING. 1�1 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 6 2014 City of Tukwila BUILDING DIVISION 050 FABRICATE AND INSTALL DUCTWORK WITH 1" DUCTLINER PER SMACNA STANDARD. INSTALL TURNING VANES AT THE ELBOWS. PURCHASE AND INSTALL FOUR DIFFUSERS WITH THE OPPOSED BLADE 'DAMPERS. SAW CUT TWO 20X20 CONCRETE WALL OPENING TO INSTALL THE OUTSIDE AIR INTAKE AND EXHAUST AIR ASSEMBLIES. PURCHASE & INSTALL A 20X20 WEATHERHOOD, WALL COLLAR, BIRDSCREEN FOR THE AIR INTAKE. PURCHASE & INSTALL A 20X20 WEATHERHOOD, WALL COLLAR, BIRDSCREEN AND BACKCRAFT DAMPER FOR THE AIR EXHAUST. 1> FABRICATE AND INSTALL SECURITY BARS ON TWO WALL OPENINGS PER DETAILS ON DWG. M515. 11 RELOCATE TWO AIR SUPPLY DIFFUSERS, SEE 1 M11 R FOR THE REMOVAL. DIFFUSER RETURN GRILL P.O.C. POINT OF CONNECTION -- A L FLEXIBLE DUCT WITH VOLUME DAMPER 24/12 RECTANGULAR DUCT, FIRST NUMBER INDICATES SIZE FOR SIDE SHOWN. 24" o f 24" W i1 340 A CFM 100 t ROUND DUCT, NUMBER INDICATES DIAMETER SUPPLY OUTLET AIR DIFFUSER/REGISTAR/GRILL. REFER TO SHEET M1A. 2-WAY EARTHQUAKE BRACING, SEE M504 4-WAY EARTHQUAKE BRACING, SEE 28c M504 G=\-AL \OT c DCO1A13A: TORIT SERIES 90 CABINET DUST COLLECTOR RATED TO 2100 CFM ©5.5" H.G. W/5 HP MOTOR, COLLECTING STEEL FILINGS. GAYLORD MODEL #MFC-500A IRAL OT 0 ALL DUCT DIMENSIONS SHOWN ARE INSIDE CLEAR. 2 ALL DUCTS WHOSE GREATEST DIMENSION IS 30" OR LESS SHALL BE 24 GAUGE GALVANIZED SHEET METAL, 3. ALL DUCTS WHOSE LARGEST DIMENSION IS BETWEEN 31" AND 54" SHALL BE 22 GAUGE GALVANIZED SHEET METAL. 4.- ALL DUCTS .WHOSE LARGEST DIMENSION IS BETWEEN 55" AND 84" SHALL BE 20 GAUGE GALVANIZED SHEET METAL. ALL DUCTS WHOSE LARGEST DIMENSION IS GREATER. THAN 85" SHALL BE 18 GAUGE GALVANIZED. SHEET METAL. REINFORCE DUCTWORK EVERY 4FT. MAX. AND SUPPORT EVERY 8FT. MAX. ALL SUPPLY DUCTS WITHIN THE BUILDING SHALL BE WRAPPED WITH 2"THICK, 1.5 POUND DENSITY FIBER GLASS INSULATION WITH AN ALUMINUM FOIL FACE, REINFORCED WITH FIBER FIBER GLASS YARN MESH AND LAMINATED TO FIRE RESISTANT KRAFT MANVILLE 800 SERIES SPIN GLAS WITH FSK FACE, OR APPROVED EQUAL. 8. DIFFUSER SIZES INDICATED ARE NECK SIZES DIFFUSERS ARE 24"X 24" T-BAR LAY -IN. CO\ STRCTO\ \JT .RETURN REDLINED PRINT BACK TO ENGINEERING WITH ANY CHANGES FROM THE DESIGN. MOON WONG, 947-4897, M/C 46-87 PURCHASE 3-TON CARRIER COOLING ONLY AIR CONDITIONER AND INSTALL THE INDOOR UNIT AT SHOWN PER MANUFACTURER INSTRUCTIONS. PURCHASE AND INSTALL A MIXING BOX WITH D.B. CONTROLS PER MANUFACTURER INSTRUCTION (MIXING BOX CONTROLS, DRY BULB SENSOR, DISCHARGE SENSOR, .ETS,). ARRANGE THE DAMPERS POSITION AS SHOWN ON DRAWING AND SET THE MINIMUM OUTSIDE DAMPER TO 0%. PURCHASE & INSTALL AN ACCESS DOOR AT THE BOTTOM OF THE MIXING BOX. INSTALL THE TERMOSTAT FOR THE AIR CONDITIONER. RECEIVED CITY OF TUKWI[_A FEB 2 4 2014 PERMIT CENTER BY APPROVED DATE A UPGRADE 13-01 782758-05 C HARRAH F BT&E SECURE DATA CENTER 15448387 M.WONG 12.20.13 B AST LAB RELOCATION J#110073-00 CH 9.12,01 C AWACS ADVANCED PROJECTS J#140965-00 �BOE/NG® ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN C HARRAH DATE SUBTITLE 7,26.98 CHECKED HVAC PLAN VIEW CURRENT REVISION 15448387 SYMBOL F DATE 12.20.13 APPROVED BY DEPT. DATE ENGINEER TITLE FREEZER OUTLET SHEET 1M11 12/20/2013 5:13:05 PM M.WONG D 13-01 REPAIR 40/45 DAMPERS 2455844 M.WONG RWS MW FOR RWS 06.15.05 04.12.06 FREEZER OUTLET W1155852 SAZAN/GB 01.03.13 CHECKED APPROVED APPROVED MECHANCIAL MASTER BUILDING 13-01 COL A-E/8-15 -J.OB... NO W1155852 COMP NO. DWG NO. D.C. 13-01--1M11 0 LEGEf SYM 1 1 /4' REVISION -x „ 1r H-1 4" AST LAB H WS HWR EL.36'- r. m HES �---~ 1 1/4" y LEI HWR 3" HWS HWR AST LAB 1 1/4, FUTURE BLUESTREAK TRANSPORTATION AISLE DATA MANAGEMENT 1oC10 14C10 TERMINAL1ROOM .-4" 11D9 (:) 0 NACTIVI C'--1 1 /2" VEST. S6 BY APPROVED -1 1/4" 1"NM' &HWR Tb Dl ;T HEATER SEE C"VG 2M11 DATE SYM 1/2" OFFICE REVISION 13C10 H WS HUGHES TOP SECT P!'T HUGHES 12010 3-TON CARRIER MODEL FV4CNF003000 W/ PURON REFRIGERANT— %" LIQUID LINE %" VAPOR LINE BY APPROVED 3„ 7'- 0„ • HUGHES 11 3-TON CARRIER MODEL 24ACC636A003 W/ PURON REFRIGERANT (ON THE ROOF) BELOW ROOF DATE 2 1/2' A PROVIDE HWS & HWR J#782758-05 B BT&E SECURE DATA CENTER 15448387 MAKING 12.20,13 J 1 /4 DBH-7r7 S7 x m a 3"x3"x1}4"L 0-1 H WS 3/4 1 1/2" GATE VALVE "L L 112°' HWR 1v1 1 1/4" AUTO. CONTROL VALVE FUNCTIONAL T „ HYDRAULIC HOSE REPIAh/4 3 x3 x1 /c 1' CW--- 1 2° PVC t1-µ 3„ �, z 1/2" 1 1/4" 3/4" GATE VALVE MECHANICAL ROOM Qi BOE/NG' tr'— 1 1 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED HWR Dr -+--- HWS DI DRAWN r� r DATE CHECKED SUBTITLE GEC SAL OT=S CO\SICTON \OHS RETURN REDLINED PRINT BACK TO ENGINEERING WITH ANY CHANGES FROM THE DESIGN. MOON WONG, 206-947-4897 1 PURCHASE AND INSTALL THE OUTDOOR AIR CONDITIONER PER DRAWING RFM61, PURCHASE AND INSTALL THE LIQUID LINE AND VAPOR LINE BETWEEN THE INDOOR AND OUTDOOR UNITS. USE ACR GRADE SOFT ANNEALED COPPER. INSULATE LIQUID LINE W/ 1" & VAPOR LINE WITH 1/2" THICK ARMAFLEX II INSULATION. THE OUTDOOR PORTION OF THE PIPING SHALL HAVE VINYL LACQUER COATING FOR CELLULAR ELASTOMERIC INSULATION, WHITE COLOR. SEE 1M61 FOR PIPING. / 3. PURCHASE AND INSTALL THE PRIMARY & SECONDARY CONDENSATE DRAIN FROM THE INDOOR UNIT TO THE LITTLE GIANT SEE DWG. 1 M111. NOTE: INSTALL 2" MINIMUM SEPARATE TRAPS FOR THE PRIMARY & SECONDARY DRAINS. SEE 1 M 111 FOR THE PIPING. 4. INSTALL THE PIPING LABELS. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 26 2014 City of Tukwila BUILDING DIVISION \CE JAWI\GS a 0 0 RECEIVED CITY OF TUKWILA FEB 242014 PERMIT CENTER HVAC PIPING PLAN 1M60 KEY VIEW SCALE: NONE CURRENT REVISION • J#782758-05 SYMBOL DATE APPROVED BY DEPT, DATE ENGINEER TITLE SHEET 1M61 12/20/2013 4:53:02 PM CHECKED APPROVED APPROVED MECHANICAL MASTER BUILDING 13-01.1 COL. A-E/8-15 DEV. CENTER, WA JOB NO. COMP NO. DWG NO, 13-01.1-1M61 LICE\D: 4" ROOF DRAIN 3/4" N.F. HOSE BIBB -•� x —x- 2" -D--3, RELIEF DAMPER (6'-5') BALL VALVE ON THE RISER (EXISTING) 1/4"0 0.D, TUBING --- AS LAB 1, 3/4" H.B. 4'-0" �✓�,,�-- ABOVE FLOOR 4" SOIL LINE 1 1/2" VTR DROP PUMPED DRAIN TO 1ST FLOOR 2" DRAIN CONNECTION 2" SS CONN, HUGHES Y „ 2 cF SYS LOCATE FLOOR DRAIN N.W. OF TEST TANK 1" C.W. --� y„ DN TO 4" C.I. UNDERGROUND 3" DUPLEX AIR OUTLETS AST LAB HON383 HDN393 V) FUTUR BLUES FREAK 3 3/4" TO D.F. & H.B. �, GATE 4'-0" ABOVE FLOOR 1 VALVE SAN. DRAIN VEST. S6 P.O.C. OP 3/4" 1/2" 1/4"0 Q.D. IA DAT 3/8"0 0.D. 3/4" IA 4 t'1 2„ 3%1010) GATE VALVE 4" ROOF DRAIN TY „ PE A AIR DROP CONNECT TO „ 3/4" TYPE-L COPPER 1 1 2" VENT THRU ROOF ERMINAL=ROOM RUN NEW BRANCH UNDER MEZZANINE 1109 1 SEE SHT. # 206 SLOPE 14C10 HUGHES 2" C 1 /2" - EL35'-6 HUCHES �?\ si OIL INTERCEPTING DRAIN • ZURN Z-690 OR EQUAL----� Y2 A GATE VALVE INACTIVE13C10 2" OFFICE i0 C.O. CSSL TOP SECRET Y" DRAIN N TYPE-L COPPER 3/4" NON -FREEZE HOSE BIBB --- L. 3 3/4" H.B. 4 -0" ABOVE FLOOR CW EL. 35'.7" TUB Y" POLYETHYLENE TUBING TO ZONE THERMOSTAT T-6, T-7 ItUTHBSAND DM-3 DAMPER OPERATOR- 3/4" 4" ROOF DR. 1 /2" 12'-6" TYPE "B" AIR 0.0. DROP SEE SH T. Y2" TYPE-L COPPER f-3-TON CARRIER MODEL FV4CNF003000 W/ PURON REFRIGERANT LITTLE GIANT VCL-24UL, 3i8HP, 115V, 148 WATTS W/ CHECK VALVE FLOO DLAN SCALE: 1/8"= 1'-0° V N. TO D.F. CW J\ CW 3/4„ DROP TO 5'-0" ABOVE FLOOR AND RUN THRU WALL -AIR CHAMBER - 15'--O" 3/4" AIR LINE r El CTInN2I' TECT ---2"C.W.TO FIRE STA-11ONAULIC HOSE REPAIR CW 2" SANITARY DRAIN FROM SUMP PUMP AT B/13 2"CW 1 1/4" VTR 3/4" FROM SUMP CR-1 MECHANICAL ROOM TEE OFF FROM 2" PLANT AIR IN THIS LOCATION N.F. HOSE BIBB 3/4" H.B. 4'-0" AFF 4" RD C.O. 3/4" GATE VALVE 4 -6" AFF 1/2" 3/4" H.B. 4'-0" AFF WATER TANK \-2" ROOF DRAIN SYS SEE FOR PIPING AT TANK 4" VTR if CAI\ OPY „ 3/4"H.B ON RISER GATE VA. ABOVE A 15'-0" SYS 2" ROOF DRAIN 5'-0„ 2"CW TO FIRE STATION SEE SHEET J PAL \OT _S• CO\STUCTIO\ \OT -S: RETURN RED -LINED PRINT BACK TO ENGINEERING WITH ANY CHANGES .FROM THE DESIGN. MOON WONG, 206-947-4897 PURCHASE AND INSTALL A SUMP PUMP AT THE CORNER OF THE ROOM AND PLUG INTO A WALL OUTLET. PURCHASE AND INSTALL THE PRIMARY & SECONDARY CONDENSATE DRAIN FROM THE INDOOR UNIT TO THE LITTLE GIANT. NOTE: INSTALL 2" MINIMUM SEPARATE TRAPS FOR THE PRIMARY & SECONDARY DRAINS. PURCHASE AND INSTALL THE PUMPED DRAIN FROM THE LITTLE GIANT TO THE EXISTING DRAIN. MODIFY THE COLD WATER PIPING TO ACCOMMODATE THE NEW DUCTWORK INSTALLATION. ALSO SEE DWG. M500. 5. INSTALL PIPING LABELS. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 6 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 4 2014 PERMIT CENTER 1 -�050 0000000® 1M110 mO / M11 / KEY VIEW SCALE: NONE SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A INSTALL SINK J#782758-00 DMV B AWACS ADVANCED PROJECTS 4140965-00 M.WONG 0;LAPPAPEAIVVG' ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN C. HARRAH DATE SUBTITLE 11.7.97 CHECKED FIRST FLOOR PLUM SING PLAN ENGINEER CURRENT REVISION J#782758-00 SHEET SYMBOL DATE 111 C BT&E SECURE DATA CENTER 15448387 M.WONG 12.20.13 APPROVED BY DEPT. DATE CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER 3,IL)I\G 13- D1 COL. A-E/8-15 D.C. v JOB NO. COMP NO. DWG NO, 13-01-1M111 2 3 TOP OF STEEL TRUSS Sc JOISTS 15 7-0 N 12 SCUPPER 11 NORTH ELEVATION SCALE: 1/8" = 1'-0" —SCUPPER SOUTH ELEVATION SCALE: 1/8" = 1'-0" �- EXISTING CHILLER UNIT & CATWALK • dr SCUPPER z .... ED i N NOTE: OPEN SPACE BELOW CANOPY — EXIST. ELECTR. EQUIPMENT of oo �� EAST ELEVATI O \ SCALE: 1/8" = TOP OF STEEL TRUSS & JOISTS 9i • qr TOP OF STEEL TRUSS & JOISTS LEGEND GE\ERAL NOTES REFERE CE DRAWINGS CONSTRUCTIO NOTES NEW WALL OPENINGS PER MECHANICAL DRAWINGS, 13-001-1 M 11 & 13-001-M515. REVIEWED FOR ODE COMPLIANCE APPROVED FEB 26 2014 City of Tukwila BUILDING DIVISION %QRECEIVED c1TLA FEB 242014 PERMIT CENTER KEY VIEW SCALE: NONE III Ilh SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE, A RELOCATE MFC MAINTENANCE SHOP J#782758-18 M.MILLER B (13-01 UPGRADE) IMO RELOCATE J#782758-12 MRM 10.06.98 C (13-01 UPGRADE) BUILDING "A & B" J#782758-05 MRM 11.04.98 D NEW WALL OPENINGS WO#15448387 S.CHO 01.06.14 gLAIRMEAIAW ® ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN M. DITTMAR IATE 9-13-95 APPROVED BY DEPT. DATE CHECKED M. MILLER ENGINEER 11-28-95 CHECKED APPROVED SUBTITLE TITLE EXTERIOR ELEVATIONS 3UILDING 13-01 CURRENT REVISION WO#15448387 SYMBOL DATE 01.06.14 SHEET A61 JOB NO. COMP NO. NG308C: 1/6/2014 APPROVED ARCHITECTURAL MASTER COL. A-E/8-15 DWG NO. M.F.C. 13-01 -A61 R NEW CONDENSING UNIT ATOP OF ROOF PER MECH. DWG. (SEE RFM61) EXISTING ROOF DECKING MEW NOTE: 1. SLEEPER ORIENTATION SHALL BE FIELD DECIDE PER ROOF DRAIN SLOPE. 2. CONTACT BOEING PUGET SOUND MAINTENANCE FOR ROOFING CONSTRUCTION. CAP FLASHING (2) 2x OR 4x WOOD SLEEPER (3'-6" MIN. LONG) WOOD CANT. STRIP (2) Y" o COUNTER -SINK THRU-BOLTS & 3x3x4 PLATE WASHER Q BOTTOM EXISTING TRUSSES AT BEYOND. S ECTI 0 \ 1 SCALE: 3/4" = 1'-0" RFM61 S512 [LA 0 50 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 6 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB Z42014 PERMIT CENTER SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE BT&E SECURE DATA CENTER WO#15448387 SC 01.07.14 OE/iYG' ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE SECTIONS & DETAILS CURRENT REVISION WO#15448387 SYMBOL DATE 01.07.14. APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED TITLE BT&E SECURE DATA BUILDING 13-001 SHEET S512 JOB NO. COMP NO. 1 /7/2014 10:20:58 AM 0 z APPROVED STRUCTURAL MASTER DEV. CENTER, WA DWG NO. 13-001—S512