Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M14-0058 - TUKWILA DELI - KITCHEN HOOD
This record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. M14-0058 TUKWILA DELI 13028 Interurban Avenue South DIGITAL RECORDS (DR)EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDESTHE FOLLOWING REDACTED INFORMATION Page #CodeExemptionBrief Explanatory DescriptionStatute/Rule The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern.As such, individuals’ social security Personal Information – numbers are redacted to protect those Social Security Numbers individuals’ privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW DR1Generally –5 U.S.C. sec. under section 42.56.070(1) of the Washington 42.56.070(1) 552(a); RCW State Public Records Act, which exempts under 42.56.070(1) the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information – expiration dates, or bank or other financial RCW account numbers, which are exempt from 28DR2Financial Information – 42.56.230(5) disclosurepursuant to RCW 42.56.230(5), RCW 42.56.230(45) except when disclosure is expressly required by or governed by other law. Personal Information – Redactions contain information used to prove RCW Driver’s License. –RCW identity, age, residential address, social security 42.56.230 (7a DR3 number or other personal information required to 42.56.230 & c) apply for a driver’s license or identicard. (7a & c) Redacted content contains a communication between client and attorney for the purpose of obtaining or providing legal advice exempt from RCW Attorney-Client Privilege –disclosure pursuant to RCW 5.60.060(2)(a), 5.60.060(2)(a); RCW 5.60.060(2)(a); RCW which protects attorney-client privileged DR4 RCW 42.56.070(1)communications, and RCW 42.56.070(1), which 42.56.070(1) protects, under the PRA, information exempt or prohibited from disclosure under another statute. TUKWILA DELI 13028 INTERURBAN AVE S M14-0058 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov MECHANICAL PERMIT Parcel No: 0004800017 Permit Number: M14-0058 Address: 13028 INTERURBAN AVE S 100 Issue Date: 8/18/2014 Permit Expires On: 2/14/2015 Project Name: TUKWILA DELI Owner: Name: EPROPERTY TAX INC DEPT #207 Address: PO BOX 4900 , SCOTTSDALE, WA, 85261 Contact Person: Name: MARK CHANG Phone: (206) 229-3557 Address: 33124 41 LN S , FEDERAL WA, WA, 98001 Contractor: Name: GREENTECH INC Phone: Address: 858 SW 312 ST, FEDERAL WAY, WA, 98023 License No: GREENI*887LK Expiration Date: 7/9/2016 Lender: Name: Address: DESCRIPTION OF WORK: REISSUANCE OF EXPIRED PERMIT M13-112: INSTALL TYPE 1 KITCHEN HOOD Valuation of Work: $8,000.00 Type of Work: Fuel type: GAS Fees Collected: $298.16 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: Permit Center Authorized Signature: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2012 2012 Date: 01060r I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: —� ` Date: Print Name: C�l�,�. _ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 6: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 1: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire -extinguishing system installed in accordance with this code. (IFC 610.2, IFC 904.2.1 and IFC 904.11) Automatic fire -extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) 4: Type I hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. (IMC 507.2.1.1) 3: All new automatic fire -extinguishing systems and all modifications to existing automatic fire -extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 9: U.L. central station supervision is required. (City Ordinance #2327) 10: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 2: Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 5: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 7: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 8: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 11: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 12: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 13: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 14: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 15: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 16: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 17: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 18: ***MECHANICAL PERMIT CONDITIONS*** 19: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 20: Manufacturers installation instructions shall be available on the job site at the time of inspection. 21: Type 1 Hoods, the required grease duct leakage test and (light test shall be performed by a special inspection and testing agency in accordance with I.M.C. Chapter 5. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0701 ROUGH -IN MECHANICAL CITY OF TUKWI Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. In I, L1-- QQ.-e Project No. Date Application Accepted: Date Application Expires: - t ' (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION ,�� // n��r / King Co Assessor's Tax No.: Site Address:/. (� � //VTmm/ /r/v i4 Y Suite Number: / 0 0 Floor: 4 Tenant Name: ��1 G/L �� New Tenant: ❑ Yes ❑.. No PROPERTY OWNER Name: izpPg`ft' 7 %Ay i /6 Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: 6 A , e 4 , `#,.. Address: ?I 2_4_41 ,1 1 / C' City State: Zipp. v Pho e: >9_ =erg Email: MECHANICAL CONTRACTOR INFORMATION Company Name: _..7.- d ce,,,v?„7, Address: / 7 r39 T ^ n, S c F,,�� Cityitz„ /�Jh��y�.�� State: tt"w Zip.p...0 s :,�/f Phone: Fax: Contr Reg No 0,co pf VdExp Date: (�ll t� t Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement ❑ Fuel Type: Electric ❑ Gas ❑ Other: H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <I00k btu Furnace > l 00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct / Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: 1 /� Print Name: HA ` j /--• vff L. Mailing Address: 3/ — 42/ C7- -/V Day Telephone: City e Zip H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 DESCRIPTIONS PermitTRAK Cash Register Receipt City of Tukwila ACCOUNT QUANTITY PAID 467.73 EL14-0805 Address: 13028 INTERURBAN AVE S 100 Apn: 0004800017 124.53 ELECTRICAL $118.60 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $118.60 TECHNOLOGY FEE $5.93 TECHNOLOGY FEE R000.322.900.04.00 0.00 $5.93 M14-0058 Address: 13028 INTERURBAN AVE S 100 pn: 0004800017 2408: MECHANICAL $229.35 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $196.85 TECHNOLOGY FEE $11.47 TECHNOLOGY FEE R000.322.900.04.00 0.00 $11.47 PG14-0032 Address: 13028 INTERURBAN AVE S 100 Apn: 0004800017 $102.38 GAS $97.50 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $65.00 TECHNOLOGY FEE $4.88 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2877 R000.322.900.04.00 0.00 $4.88 $467.73 Date Paid: Monday, August 18, 2014 Paid By: GREENTECH INC Pay Method: CHECK 1252 Printed: Monday, August 18, 2014 9:38 AM 1 of 1 'SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY I PAID PermitTRAK $57.34 M14-0058 Address: 13028 INTERURBAN AVE S 100 Apn: 0004800017 $57.34 MECHANICAL $57.34 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R1398 R000.322.102.00.00 $57.34 $57.34 Date Paid: Thursday, March 06, 2014 Paid By: YONGSOK CHANG Pay Method: CREDIT CARD 034113 Printed: Thursday, March 06, 2014 10:41 AM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit. INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: 'Type of Inspection: Address: Date Date Called: Special Instructions: Date Wanted: Requester: VApproved per applicable codes. EJCorrections required prior to approval. COMMENTS: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 INSPECTION RECORD Retain a copy with permit Project: - Type of Inspection: Address: _ Date Called: Special Instructions: Date Wanted: Requester: No: X Phone Approved per applicable codes. (Corrections required prior to approval. COMMENTS: Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Type of Inspection: %J ''44) Address: Date Called: Special Instructions: Date Wanted: Requester: Phone No: JApproved per applicable codes. :orrections required prior to approval. COMMENTS: Inspector: REINSPECTION FEE'REQUIRED: Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 7 `- '4 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Inspection: Special Instructions: Date Wanted: Requester: Phone No: /Approved per applicable codes. I] Corrections required prior to approval. COMMENTS: Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Dater 4 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 [y7/4'-a . Pro' Of KKO/Z-4 Type In pection: r g h — f by Add s.;, Ith; /p7/ p4 p Date Called: y Special lnstructions: Date rated: — 2 — /y n. per,, Requester,.. C'_./ d1 rt ) i, j5 3/7/ Approved per applicable codes. (Corrections required prior to approval. COMMENTS: I) \t`C'4-\Ztirec• - c7 (' i✓ TNT `t t U Inspector: C_S2 \ u- Date: R INSPECTION FEE REQUIRED. Prior t pal \a0`. t 6300 Southcenter Blvd.. Suite 10 next inspection, fee must be Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER -7' /v-r-Z63 ,4/%-- oo4 PERMIT NUMBERS CITY OF TUKWILAFIREDEPARTMENT 206-575-4407 Project: Type of` spection: 7, Address: ---- Suite #: aDZel��.L-X-S Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: , 6.20 400, ,/O 74 %�,eC/�� // 4s,1" -- /2--;;c1-5-S Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:. DDate: /0 6,x Hrs.: / d $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Address: Company Name: .City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project j I.ki t,Type t to of Inspection: Address: L-\ Suite #: 1 E -,,,t,L„r- ANA, Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: - '/ -..- At 7.1/45/,,-/-,(., ,ice (AA_ evet7D4,,..... Cyr,.--, ( !1'74rr,./-A . 4 0 4 /1/0-1— 0,- h€ /7 A le-Eb A ")-) _< /4 r- " .._ ... . ,/-2_,2.,-,1,-, Af /-x 4/:•4>44,-/A, Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct:T. Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: //c.11'53 Date: /p / y Hrs.: / C.) $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Krazan & A--SSOCTATRS, INr- GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERIN CONSTRUCTION TESTING & INSPECTION September 24, 2014 City of Tukwila Attn: Bldg Dept. 6200 Southcenter Blvd. Tukwila, WA 98188 RE: Final Letter Tukwila Deli 13028 Interurban Ave S. Tukwila, WA 98168 To Whom It May Concern: KA No. 066-14235 Permit No. M14-0058 RECEIVED CITY OF TUKWILA DEC 0 3 2014 PERMIT CENTER In accordance with our clients request and authorization, we have performed special testing and inspection services for the above referenced project. The special inspections for this project were: Grease Duct Inspection To the best of our knowledge, all work has been tested and inspected and has been found to be in general accordance with the approved plans and specifications, and engineering revisions, and chapter 17 of the 2012 international Building Code. If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office at (253) 939-2500. Respectfully submitted, KRAZAN & ASSOCIATES, INC William B Throne Operations Manager Puyallup CC: Paul Kim With Offices Serving The Western United States 922 — Valley Avenue NW Suite 101 • Puyallup, WA 98371 • (253) 939-2500 • Fax: (253) 939-2556 ..,-,..... i< ire azaZ & ASSOCLATF.S, INC GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION September 24, 2014 ReGE-N° S�, 2g 2014 MM pM� y T City of Tukwila OEVEt-O EN Attn: Bldg Dept. 6200 Southcenter Blvd. Tukwila, WA 98188 RE: Final Letter Tukwila Deli 13028 Interurban Ave S. Tukwila, WA 98168 To Whom It May Concern: KA No. 066-14235 Permit No. M14-0058 In accordance with our clients request and authorization, we have performed special testing and inspection services for the above referenced project. The special inspections for this project were: • Grease Duct Inspection To the best of our knowledge, all work has been tested and inspected and has been found to be in general accordance with the approved plans and specifications, and engineering revisions, and chapter 17 of the 2012 international Building Code. If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office at (253) 939-2500. Respectfully submitted, KRAZAN & ASSOCIATES, INC William B Throne Operations Manager Puyallup CC: Paul Kim With Offices Serving The Western United States 922 — Valley Avenue NW Suite 101 • Puyallup, WA 98371 • (253) 939-2500 • Fax: (253) 939-2556 • FILE COPY P. rm t No. yg A4 eNcrttris,6 REVIEWED CODE COMPL APPROVED MAR 12 2014 P-kfaU.T {A(►J 114 0058 kbEtA.4 AVAirc Iu Z21Os S1 Wes. (ice r0 St% &WI 5114)C CITY OF TUKWILA MAR 0 6 2014 PERMIT CENTER sheet City of Tukwila BUILDING DIVISION dent (s)Y6•0_291.ert_ 2 ./7,7 1, r NteAttsrri1/414 (+Srw/u INA rriosArIPOO REVIEWED FOR CODAPPROVED CE' MAR 12 2014 • Poled • City of Tukwila NNG DIVISION v boaelicks >y� RECEIVE) CITY OF TUKWILA MAR 0 6 2014 PERMIT CENTER by location date ono. ibb no. • rkmituo REVIEWED FOR CODE COMPLIANCE APPROVED MAR 12 2014 City of Tukwila BUILDING DIVISION sVPVax uY71#. 1 (lt%a ut41T ttoa sc-ocetl --f RECEIVED CITY OF TUKWILA MAR 0 6 2014 PERMIT CENTER Poled by location date ono. ono. Thermal cemrnics Fire Protection Systems Product Data and Installation Guide 5Br7^ a oANA c ® -ii NFPA 96 IMC 1. Product Description - New and improved FastWrap+ Thermal Ceramics new and improved FireMaster FastWrap+ is a one -layer, totally foil -encapsulated, non-combustible 2000°F (1093°C) rated, low biopersistence, flexible fireproofing wrap specif- ically tested to provide a 1 or 2 hour fire rated enclosure for hori- zontal and vertical commercial kitchen grease and air ventilation ducts. The core blanket chemistry is alkaline -earth silicate wool free of binders and lubricants. FastWrap+ is classified by Omega Point Laboratories and Underwriter's Laboratories Listing and Follow-up Service Program to ensure uniform thickness and density specifica- tions, thus providing consistency in end physical properties for required fire ratings. FastWrap+ is a proven performance alterna- tive through extensive testing to 1 or 2 hour fire -resistance rated shaft enclosures. With its excellent insulating capability of with- standing fire condition temperatures up to 2000°F (1093°C), it pro- tects combustible constructions at zero clearance throughout the entire enclosure system. When the duct penetrates fire rated walls and floors, an approved silicone firestop sealant used in combina- tion with FastWrap+ provides an alternate means of protection to rigid shafts by maintaining the integrity of the 1 or 2 hour fire rated wall and floor assembly. FireMaster FastWrap+ is resistant to mold growth in test conditions of 75-95% relative humidity (ASTM D6329). Product Features • One -layer system with 3 optional installation techniques • Low biopersistent insulation blanket • Does not contain low temperature fiberglass or mineral wool • Shaft alternative to rigid board systems • Zero clearance to combustibles protection throughout the entire enclosure system • Lightweight, flexible wrap saves labor • Passive fire proof material does not shrink, become brittle, or lose fire fighting capabilities with age • Totally foil encapsulated system protects against material degra- dation, and potential fire hazards • Product markings on foil ensure proper material identification for easy inspections • Wide variety of through -penetration systems • Resistant to mold growth 2. Applications • 1 or 2 Ho>;rmmerciat'ttlen Grease Duct Enclosure • 1 RE.VSKENRInTlIala Duct Enclosure CODE COMPLIANCE RECEIVED APhRO'VED CITY OF TUKWILA MAR 1.2 2014 MAR 0 6 2014 City of Tukwila PERMIT CENTER BUILDING DIVISION FastWrap+ 11/2' Commercial Kitchen Grease Duc Air Ventilation Duc 3. Physical Characteristics FireMaster Product Unit Size Units/ Ctn. WtJ Ctn. FastWrap+ Roll 11/2' x 24" x 25' (38.1 mm x 610 mm x 7.6 m) 1 37.5 It (17kg FastWrap+ Roll 11/2" x 48" x 25' (38.1 mm x 1.2 m x 7.6 m) 1 75 lbs. (34 kg FastWrap+ Collar Roll 11/2" x 6" x 25' (38.1 mm x 152 mm x 7.6 m) 4 53 Ibs (24 kg Color White blanket with silver foil encapsulation 4. Specifications This specification guide covers the application of Thermal Ceramic FireMaster FastWrap+ and An approved silicone firestop sealant. Application Fire Resistive Rating Enclosure System Through Penetration System Grease Ducts 1 or 2 hours 1 layer, 11/2" FastWrap+, perimeter and longitudinal overlap 3° (75 mm), GO 544 F, GO 562 F, UL G-14 OPL FS 587F UL C-AJ-709f Air Ducts 2 hours 1 layer, 11/2" FastWrap+, perimeter and longitudinal overlap 3" (75 mm), UL V-19 C-AJ-7095, UL-W-L-7121 UL-F-C-7036 5. Performance A. Thermal Ceramics FireMaster FastWrap+ Flammability (ASTM # 84/UL 723) Foil: Flame spread 5 Smoke developed 10 Blanket: Flame spread 0 Smoke developed 0 Thermal Resistance R value per ASTM C 518 4.15 per inch at 70°F (21°C) B. Fire Stop Sealants Tremco inc. Fyre Sil sealant or Fyre-Sil S/L Sealant (for floor assemblies only) Specified Technologies Inc. Pensil 300 Rectoseal 835+ Sealant HILT! Construction Chemicals, Division of HILT! inc. FS One Sealant rmal Ceramps C. Listings Agency Reference Standard/Fife No. Omega Point Laboratories, Inc. Listing # 11660-3 Underwriters Laboratory Grease Duct Enclosures (YYET): R14229; Are Resistive Ventilation Duct Assemblies (HNJL): V-19; Through - Penetration FireStop System (XHEZ): C-AJ-7095, C-AJ-7098 NFPA Complies with NFPA 96, 2001 Edition International Mechanical Code Section 506.10.3 Commercial Kitchen Grease Ducts and Exhaust Equipment, Section 507 Commercial Kitchen Hoods, 2003 Edition New York MEA 412-02-M, 413-02-M International Code Council SBCCI Legacy Report No. 9424E BOCA Legacy Report No. 22.25 City of Los Angeles RR8425 California State Fire Marshal 2440-1361:103 2440-1361:105 6. Installation A qualified contractor in aceo tions and referenced standar FireMaster FastWrap+ system described in sections A-D. S details. Materials and Equipment: FireMaster FastWrap+ blanket, 1/2" (38.1 mm) thick, 6 pcf ( kg/m'), 24" (600 mm), or 48" (1.2 } ) wide, and 25' (7.6 m) long roll optional 6" wide x 20' tong (150 m x t' olds r • FireMaster FastWrap+: 25' (7.6 1st j33 . • (r 2g IAA l �ul+ mm) wide blanket helps to .min • Aluminum foil tape • Minimum IV (19.0 mm) wide filament tape (optional) • Carbon steel or stainless steel banding material, minimum' " (12.5 mm) wide, minimum 0.015° (0.38 mm) thick, with steel banding clips • Hand banding tensioner and crimping tool • Minimum 12 gage steel insulation pins; galvanized steel speed clips, minimum 1Y (38 mm) x 11/2" (38 mm) square or 1/" dia. (38 mm), or equivalent sized cup -head pins; capacitor discharge stud gun • Access door hardware: four galvanized steel threaded rods, '/4" diameter (6.35 mm) by 4' " to 5" long (114 to 127 mm) with Ys" (6.35 mm) wing nuts and Y4" (6.35 mm) washers; 4" (102 mm) long steel tubing to fit threaded rods • An approved silicone firestop sealant Storage: The FireMaster FastWrap+ and an approved silicone firestop sealant must be stored in a dry warehouse environment on pallets. Pallets should not be stacked. mff!°ai'"'"' sirub- sha tfa =t vr igin'aI 1100SteillMaatgagiAs FigureAtt-MSVgji drawing MAR 12 2014 Preparatory Work. FireMaster FastWrap+ is installed with common tools, such as knives, benders and capacitor discharge guns for applying insula- tion pins. In order to install the duct fire stop system, the surfaces of all openings and penetrating items need to be clean, dry, frost free, and free of dust. Installation techniques for Thermal Ceramics FireMaster FastWrap+ (Figures 1 and 3): • 3" (75 mm) Overlap Wrap Telescope - Each blanket overlaps one adjacent blanket, and each blanket has one edge exposed and one edge covered by the next blanket as shown in Figures 1 and 3. The visible edges of the longitudinal overlaps all point in the same direction. • Overlap Checkerboard Pattern - Blankets with both edges exposed alternate with blankets with covered edges, as shown in Figures 1 and 3. The visible edges of the longitudinal overlaps alternate their directions and appear on every other blanket. • Butt Joint & Collar System - Adjacent blankets are butted tight- ly together and a 6" (152 mm) wide collar of FireMaster FastWrap+ is centered over the joint, overlapping each blanket by 3" (75 mm) as shown in Figures 1 and 3. • 2 & 3 Sided Enclosure System - When space does not allow for full wrap enclosure on all four sides of the duct, the FireMaster FastWrap+ may be installed on 2 or 3 sides of the duct and mechanically attached to a concrete or CMU assembly on the unexposed side of the duct. General: To minimize waste, FireMaster material should be rolled out tautly before measuring. Cut edges of the blanket shall be taped with alu- minum foil tape to prevent exposed edges of the insulation from wicking moisture from condensation or grease from a compromised leaking duct joint into the material and causing degradation of the fire barrier. The FireMaster FastWrap+ material may be installed with either a mechanical banding system or insulation pins and clips (see Mechanical Attachment Methods below and Figures 1 and 3). When using the banding technique, caution shall be taken to ensure that the bands are not fitted too snug as which could result in cut- ting into the blanket. To prevent blanket sag on ducts with dimen- sions greater than or equal to 24° (600 mm), insulation pins, long enough to extend through the layers of blanket insulation, are weed- ed to the duct in columns spaced 12" (305 mm) apart, between 6" and 12' (152 and 305 mm) from each edge and 101/2' (267 mm) on center along the bottom horizontal and outside vertical duct runs. Insulation pins that extend beyond the blanket wrap shall be tuned down to eliminate sharp points. Support hanger systems do not need to be wrapped provided that the steel hanger rods are at least a minimum of (9.5 mm) diameter and the steel angle is a mini- mum of 1'�" x 1 1' x '/e" (38 mm x 38 mm x 3.2 mm), or SMACNA equivalent support system (SMACNA band strap support systems do not apply). Horizontal trapeze support systems may be incorpo- rated into the wrap enclosure. A. Overlap Wrap Telescope Installation FireMaster FastWrap+ commercial kitchen grease or air ventilation duct 1 or 2 hour enclosure includes a one -layer wrap construction applied directly to all surfaces of the duct (Figures 1 and 3). The FireMaster FastWrap+ blanket is wrapped one layer 11/2" (38.1 mm) or 2" (50 mm) thick around the perimeter of the duct with a length cut to provide enough excess to overlap itself not less than 3" (75 mm). Adjacent blankets are placed to overlap the previous blanket not less than 3" (75 mm). The overlap made by adjacent blankets forms the "longitudinal" overlap. The overlap a blanket makes with itself is called the "perimeter" overlap. The wrap layer may be held temporarily in place with filament tape 1 Yz" (38 mm) from each blan- ket edge and in the center of the blanket until the mechanical band- ing or pinning and dip attachment method is secured. B. Checkerboard Wrap Installation FireMaster FastWrap+ is cut to completely wrap around the perime- ter of the duct with enough excess to provide an overlap of not less than 3" (75 mm) (Figures 1 and 3). The blankets with both edges exposed alternate with blankets with covered edges as shown in Figures 1 and 3. The visible edges of the longitudinal overlaps alter- nate their directions and appear on every other blan t (75 mm) longitudinal overlap is installed onto the previ Fhd s 0 wrap forming a "checkerboard' construction. Tlie 1/tYPQ6a-rialgi, /iL1 be held temporarily in place with filament tape 11" (38 mm) from each blanket edge and in the center of the blanket untilftin2014 ical banding or pinning and clip attachment method is secured. PERMIT CENTER . • The repair section is to be centered on the opening and impaled upon the insulation pins. All overlaps should be tucked into the repair opening to provide a tight fitting joint. Insulation is held in place with a 1'h" square or round galva- nized or stainless steel speed dip or a minimum 1 ° diameter cup head pin. The excess portion of the pin shall be cut off and/or turned down to eliminate sharp edges. • The joint should be sealed using aluminum foil tape. 8. Limitations • FireMaster FastWrap+ shall be installed in accordance with Thermal Ceramics - Installation Instructions • Multiple steel ducts in a single FireMaster FastWrap+ enclo- sure system are not permitted for commercial kitchen grease ducts. Multiple steel ducts in a single enclosure are permitted for air ventilation ducts • Grease Duct Sizes > 24"x48" (600 mm x 1200 mm) insula- tion is attached using steel pins • Air Ducts: when maximum duct size dimensions are greater than 84" x 21" (2100 mm x 525 mm) in cross section, rein- force the duct with steel angles sufficient to support the total weight of the duct assembly and the FireMaster FastWrap+ enclosure Thermal Ceramics F/ R Fire Protection Systems New and Improved FireMaster 1'h" FastWrap+ Commercial Kitchen Grease or Air Ventilation Duct 1 or 2 Hour. Shaft Alternative Zero Clearance to Combustibles OPL Design No. GD 544 F and GD 562 F Figure 1 UL Design No. G-14 and V-19 Drawing No. FMFW1.5001-1 1 One layer FireMaster FastWrap+ 11h" thick 2 Steel banding Yi wide minimum 3 3" minimum longitudinal overlap 4 3" minimum perimeter overlap 5 6" wide FastWrap+ collar (for Butt Joint option) 6 Firmly butted joint (for Butt Joint option) 7 10 or 12 gauge steel insulation pin with 1 Ye x 11/2" or 1 Y2" diameter galvanized speed clips (for alternate pinning) Note: The integrity of FireMaster Duct Systems is limited to the quality of the installation. • Minimum 3/8" (9 mm) diameter all thread steel rods do not have to be insulated • Horizontal support members may be incorporated into the enclosure wrap • The integrity of FireMaster FastWrap+ system is limited to the quality of the installation *For personal protective equipment recommendations see the MSDS. Thermal Ceramics Is a trademark of Morgan Crucible Company plc. FlreMaster and FastWrep are trademarks of Thermal Ceramics Inc. FestWrap products are manufactured by Thermal Ceramics Inc. FireMaster Duct Systems am distributed by authorized distributors and no longer by 3M. Remo and Fyre-Sil ere tradenames of Tromso Inc. Penult Is a tradsname of Specified Technologies Inc. 835* is a tradename of Rectorate:. FS One Is a tradename of HILTI Inc. Special Note: The original FireMaster FastWrap+ 2" technical data and installation sheet is still available elec- tronically at www.thermalceramics.com in the data sheets section. RECEIVED CITY OF TUKvVILA MAR 0 6 2014 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED MAR 12 2014 City of Tukwila BUILDING DIVISION Alternate Pinning Technique Grease Ducts Only: Sizes Z 24"x48" In Cross Section Pinning Technique Required. 11/2" Butt Joint Option Cross Section View 1 1r2 21" TYP. .I Overlap Wrap Option Cross Section View 1 1rr Checkerboard Wrap Option Cross Section View a 0 0 -tua meal 0 CD ai w -0�0as ✓ m rizt • OS m o E ��oaa3 Sa 03 0 0 city 0 p tjt a� •.°of� . on � .. • be CC at ho U E -ct -4 2a 0 44 4-4 04 c PAr Length of Hood 4,09 01 „9E :gt 4-3 Cd W _ 0 0 20" Baffle Grease Filter Stainless Steel Grease Cup REVIEWED FOR CODE COMPLIANCE APPROVED MAR 12 2014 City of Tukwila BUILDING DIVISION y !z RECEIVED CITY OF TUKWILA MAR 0 6 2014 PERMIT CENTER EQUIPMENT Hood 4 -2-PSP-F - 9ft 0" Long Exhaust -Only Wall Canopy Hood w th Front Perforated Supply Plenum with in 3" Back Standoff -430 SS Where Exposed - FILTER - 16' tall x 16' wide kleen-Gard Stainless Steel Baffle Fier with Candles and Bottom Harming Hook IL Classified - FILTER -16'ta0 x 20° wide Kleen-Gard Stem Steel Baffle Filter nth Handles and Bottom Hanging Hook UL Classified - Incandescent Light Fbdure-H lgh Temp Assembly. Includes Clear Thermal and Slack Rent Globe (L55 Fixture), Bulbs By Others - EXHAUST RISER- Field Curt to' X 19" - FIELD CUT, SHIP LOOSE - SUPPLY RISER - 10"x 20" Supply Riser wlh Volume Dampers -12 Phd Grease Cup New Style, Flanged Slotted - INSULATION FOR BACK STANDOFF - BACKSPLASH 80.00" High X 108.00" Long X 1.00' Wide insulated 430 SS - BACKSPLASH 96.00' High X 18.00" Long 430 SS -Face Mount 1st Switch - Face Mount Extra Swlt h(es) Fault VXDSS - Exhaust Fan REVIEWED FOR CODE COMPLIANCE APPROVED MAR 12 2014 City of Tukwila BUILDING DIVISION VXD85 High Speed Direct Drive Centrifugal Upblast Exhaust Fan with speed control (single phase only), disconnect switch and 15-3/4" wheel. Exhaust Fan handles 2025 CFM @ -0.850" we ESP, Fan runs at 1259 RPM. Exhaust Motor 0.750 HP, 1 Phase 115 V.13.0 FLA, ODP (Open Drip Proof) - Grease Cup for kitchen -dirty centrifugal exhaust fans. Box Dimensions 15-3/4 L X 5-1/16 W X 3-3/4 H (18 GA.) (includes Down Spout) - Curb CRB23X20E On Fan # 1 -Hinged Base for Curb. Standard Hinge attached to curb. Used on Fans wlth wheels 20 inches or smaller. 12 GA Galvanized. -Vented Base for Curb Fan #2 VA1-G10 - Supply Fan VAI-G10 Untempered Supply Un0 with 10° Blower in Size #1 Housing Supply Fan handles 1620 CFM @ 0.350" we ESP. Fan runs at 662 RPM. Supply Motor. 0.500 HP, 1 Phase 115 V, 8.0 FLA, ODP (Open Drip Proof) Down Discharge - Air Flow Right -> Left - Sloped Fdtered Intake for Size #1 Modular Untempered Supply Unit. 21.813" Wide x 44.375" Long x 23.375° MIL Includes 2" MV EZ Kteen Metal Mesh Filters. -Gravity Back Draft Damper, 16" wide x 18" high, Standard Galvanized Construction,1 1/4' Rear Flange, for Sze 1 Untempered Fan Housing (5181) -Curb CRB21X15 On Fan # 2 xl RECEIVED CITY OF TUKWILA MAR 0 6 2014 PERMIT CENTER PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0058 DATE: 03/06/14 PROJECT NAME: TUKWILA DELI SITE ADDRESS: 13028 INTERURBAN AVE S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Vu V.tti AIM >Ito& 3-t\-M Building Division Fire Prevention Public Works Structural Planning Division Permit Coordinator II PRELIMINARY REVIEW: Not Applicable n (no approval/review required) REVIEWER'S INITIALS: DATE: 03/11/14 Structural Review Required DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Notation: DUE DATE: 04/08/14 Approved with Conditions 4,ix: Denied (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping 0 PW ❑ Staff Initials: 12/18/2013 Greentech Inc Page 1 of 2 41.11114 Washington State Department of Lab©r & Industries Greentech Inc Owner or tradesperson SUNG, CHANG WOON Principals SUNG, CHANG WOON, MANAGER Doing business as Greentech Inc WA UBI No. 603 036 407 858 SW 312th St FEDERAL WAY, WA98023 206-853-3971 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties Heating/Vent/Air-Conditioning and Refrig (HVAC/R) License no. GREENI*887LK Effective — expiration 06/12/2012— 07/09/2016 Bond No bond accounts during the previous 6 year period. Insurance Security National Insurance Policy no. na102657502 Received by L&I 06/20/2014 Insurance history Savings (in lieu of bond) Received by L&I 06/12/2012 Savings account ID Active. Meets current requirements. $1,000,000.00 Effective date 06/20/2014 Expiration date 06/20/2015 $6, 000.00 Effective date 06/12/2012 Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603036407&LIC=GREENI*887LK&SAW= 08/18/2014