Loading...
HomeMy WebLinkAboutPermit M14-0060 - NEPTUNE SOCIETY - DUCTWORK AND FANNEPTUNE SOCIETY 672 STRANDER BLVD M14-0060 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0005800037 Permit Number: M14-0060 672 STRANDER BLVD Project Name: NEPTUNE SOCIETY Issue Date: 3/20/2014 Permit Expires On: 9/16/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BC PARTNERS LLC PO BOX 997 C/O MK PROPERTY SVC LLC, SNOQUALMIE, WA, 98065 AL ALDRICH PO BOX 66070 , SEATTLE, WA, 98166 NORTHWEST AIRE SERVICES INC. PO BOX 66070 , SEATTLE, WA, 981696 NORTHAS963K4 Phone: (206) 241-2657 Phone: (206) 241-2657 Expiration Date: 5/24/2014 DESCRIPTION OF WORK: MINOR INTERIOR DUCTWORK ALTERATIONS AS REQUIRED TO ACCOMODATE THE NEW FLOOR PLAN. INSTALL (1) NEW CEILING MOUNT EXHAUST FAN. RELOCATE EXISTING THERMOSTAT Valuation of Work: $6,785.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $285.10 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer Distric: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Signature Date: � be/�7 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit aryd"agree to the conditions attached to this permit. Signature: Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** Site Address: (07� .e.u.e. Bova Tenant Name: E A E'4L.Mf6 Sod."E Name: gLo R42'24iVc"/ ,`..� Address: City: suDpl4aLifrni_ State:4)4 Zipvexti King Co Assessor's Tax No.: Suite Number: 000 S$0 -6b37 Floor: New Tenant: Rt.Yes ..No Company Name: /4wa-14/ji Address 2.74 CityE State:/ 4 Zipgp 166 PhoneZ� /��,7 Fax:2 zt1 Z4, / CopYr Reg 14.4,3K Exp Date: 5/ /,f Tukwila Business License No.: ,, 2 4O % Valuation of project (contractor's bid price): $ Describe the scope of work in detail: i�C rhoo �1 ile-L1 Cti,/E eE/%zrf A4tuA-r Rio iA /A5 s7j- Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement ❑am�J�% j� Fuel Type: Electric � £.-- Gas ❑ Other: /.�.ii/j %/641 —Rigs -i/, H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11 docx Revised: August 2011 Page 1 of 2 bh Indicate type of mechanical work being installed and the quantity below: Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Air handling unit. >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Fire damper Diffuser 13 Thermostat Wood/gas stove Emergency generator Other mechanical equipment ressol its 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu H1 ' ' N t Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A 1 RI D AGENT: Signature: L� Date: 3//U/ 4 Print Name: Afi S L & Day Telephone: 2S3 Z23 / € ) Mailing Address: AWL 6466%4C) H: ApplicationsWorms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh S& rE- City Lfi�4 State .9z. Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $230.27 M14-0060 Address: 672 STRANDER BLVD Apn: 0005800037 $230.27 MECHANICAL $219.30 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $186.80 TECHNOLOGY FEE $10.97 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R1548 R000.322.900.04.00 $10.97 $230.27 Date Paid: Thursday, March 20, 2014 Paid By: NORTHWEST AIRE SERV Pay Method: CREDIT CARD 06441C Printed: Thursday, March 20, 2014 2:12 PM 1 of 1 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID $54.83 $54.83 $54.83 $54.83 $54.83 PermitTRAK M14-0060 Address: 672 STRANDER BLVD Apn: 0005800037 MECHANICAL PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R1427 R000.322.102.00.00 Date Paid: Monday, March 10, 2014 Paid By: AL ALDRICH NORTHWEST AIRE SERV Pay Method: CREDIT CARD 00959C Printed: Monday, March 10, 2014 2:10 PM 1 of 1 CR SYSTEMS M 11 -ro(9Co INSPECTION NO. PERMIT NO. ;r•�J CITY OF TUKWILA BUILDING DIVISION v"( 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 INSPECTION RECORD Retain a copy with permit Proje cy j I J ke S t `. Type -of Inspection:j __ p Addrz ss. �` sue,_ w ,o Date4{ed:F ` t Special Instructions: M`./ al,. Dili Date Wanted 3... Z'- Q"p]e p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: p pf `,it Lev kid el() Inspeor: .JV Dater REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Calt to schedule reinspection. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0060 PROJECT NAME: NEPTUNE SOCIETY SITE ADDRESS: 672 STRANDER BLVD X Original Plan Submittal Response to Correction Letter # DATE: 03/10/14 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: (iuG A144 AM 411 Building Division III Fire Prevention Public Works Structural Planning Division Permit Coordinator it PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 03/11/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04/08/14 Approved Approved with Conditions Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 NORTHWEST AIRE SERVICES INr' Page 1 of 2 Washington State Department of Labor & industries NORTHWEST AIRE SERVICES INC Owner or tradesperson BEDELL, GARY E Principals BEDELL, GARY E BEDELL, KYLE E SHAW, BARBARA L (End: 05/19/2010) Doing business as NORTHWEST AIRE SERVICES INC WA UBI No. 602 387 574 PO BOX 66070 SEATTLE, WA98166 206-241-2657 KING County Business type Corporation Governing persons BARBARALSHAW License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. NORTHAS963K4 Effective — expiration 05/24/2004 — 05/24/2014 Bond WESTERN SURETY CO Bond account no. 69710416 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 05/24/2004 05/10/2004 Insurance Hartford Casualty Ins Co $1,000,000.00 Policy no. 01 SBAAM7713 Received by L&I Effective date 03/29/2013 05/11/2012 Expiration date 05/11/2014 Savings No savings accounts during the previous 6 year period. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602387574&LIC=NORTHAS963K4&SAW= 03/20/2014 PROJECT DATA: SITE DATA: PROJECT ADDRESS: 672 STRANDER BLVD. TUKWILA, WA 98188 CURRENT ZONING: TUC (CITY OF TUKWILA) PARCEL NUMBER: 000580-0037 PROJECT TEAM: BUILDING OWNER: BC PARTNERS,LLC C/O MK PROPERTY SERVICES SNOQUALMIE, WA, 98065 425-888-2993 TENANT: THE NEPTUNE SOCIETY ARCHITECTURAL: urban solutions studio, Ilc 1555 UNION AVE NE, #66 RENTON, WA 98059 (425) 922-1474 CONTACT: GARY B. BARBER, AIA GENERAL CONTRACTOR: EDI 12920 S.E. 95th Way NEWCASTLE, WA 98056 (425) 255-5467 CONTACT: CHUCK LINDBERG WASHINGTON STATE UC. #: CC ENRIC0112809 WORK DESCRIPTION: 1. Minor interior ductwork alterations as required to accommodate the new floor plan. 2. Installation of (1) new ceiling mount exhaust fan for the new public toilet. 3. Relocate the existing thermostat. OCCUPANCY: GROUP B CONSTRUCTION TYPE: V-B SPRINKLERED (EXISTING) PARKING PROVIDED: NO CHANGE VALUATION OF WORK $6,785.00 LEGAL DESCRIPTION MEADER HENRY D-C #46 LOT 1 OF CITY OF TUKWILA SHORT PLAT NO 84-31-SS RECORDING NO 8501030748 SD SHORT PLAT DAF - POR NW 1/4 OF SEC 25-23-04-BAAP ON WLY R/W LN OF WEST VALLEY HWY SR 181 AT A PT WCH BEARS S 81-07-31 W 50 FT FR C/L THOF AT HWY ENGR STA 160+00 TH FR SD POB ALG SD WLY R/W LN S 12-18-30 E 250.45 FT TAP WCH BEARS S 81-07-31 W 35 FT FR C/L AT HWY ENGR STA 162+50 TH S 05-15-06 E 112.35 FT TH TANGENT TO PRECEDING COURSE ALG ARC OF CURVE TO RGT RAD 50 FT & A C/A OF 86-22-37 ARC LENGTH 75.38 FT TAP ON NLY R/W LN OF STRANDER BLVD TH ALG SD NLY R/W LN TANGENT TO PRECEDING CURVE S 81-07-31 W 28.58 FT TH TANGENT TO PRECEDING COURSE ALG ARC OF CURVE TO LFT RAD 700 FT & C/A OF19-33-22 ARC LENGTH 238.92 FT TH TANGENT TO PRECEDING CURVE S 61-34-09 W TO INTSN OF SD NLY R/W LN OF STRANDER BLVD WITH ELY BANK OF GREEN RIVER TH NLY ALG SD ELY BANK TO INTSN WITH SLY LN OF BOW LAKE P/L RAN 30 FT WIDE TH ALG SD SLY LNS S 87-12-48 E 194.01 FT TAP ON WLY R/W LN OF SD WEST VALLEY HWY TH ALG SD WLY R/W LN S 08-52-29 E 165.06 FT TO POB ENERGY CODE NOTES NO BUILDING ENVELOPE MODIFICATIONS TO CONDITIONED SPACES ARE PROPOSED. ANY WORK SHALL MEET OR EXCEED ANY PERTINENT CITY OF SEATTLE ENERGY CODE REQUIREMENTS. g-CRA SITE PLAN NTS HVAC General Notes: Codes . Complete alterations of the mechanical system shall be per the most current applicable building, mechanical, energy and fire codes, and regulations, as adapted by the City of Tukwila. Insulation/Linina/Sealant Notes As a minimum, comply with the thickness and types listed in the energy code enforced by the City of Tukwila. Air System Balancing C408.2.2.1 Air balance volume's at all supply and return outlets to be as indicated per sheet M/1 and as in accordance with the requirements of Chapter 6 of the International Mechanical Code. Occupancy Air Volume Minimum Occupancy air volumes per 2012 International Mechanical Code, Table 403.3, for Type Group `B" Occupancy. System design @ .06 CFM perr square foot. Total space square footage = 1,800 1,800 x .06 =108 CFM Occupancy Air provided via air side economizer set at the minimum open position. Sheet Metal Notes Reference _SMACNA HVAC Duct Construction Standards, Metal and Flexible, Current Edition. Volume Dampers Provide an accessible, lockable, manual air volume control damper for each relocated supply or return air opening if none exist. Thermostat Existing control, position @ 5 ft AFF, locate as indicated. HVAC LEGEND SUPPLY AIR RETURN AIR' OR CROSSOVER DUCT VOLUME DAMPER THERMOSTAT FLEXIBLE DUCT SHEETMETAL DUCT X k3t444pwe no crivv- 0.5.11)5 J i.44- lira. PPROX. AREA OF WORK SEPARATE PERMIT REQUIRED FOR: •❑ Mechanical [electrical Ii"Piumbing COGas Piping City of Tukwila Rs f",".NG DIVISION REC-' IC N/WAI • ,.. Ib" FAMILY ROO ' # to" c4--Ires ;J e• so ccon EVO - grA0 SALES CENTER B SI NTER `-----,, E ts41 o5 I o' SD C..Fol REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. EMPL.• TOILET Fl IL Ez.is4;41 s2 4-u1,o14 PSG . Kicw thia4. loVolek REFLECTED CEILING PLAN 3/16 = 1'-0" U 03 r7 r7 .I• w 0 23'-4 1/2" CLR (E) RECEPTION / WAITING 6'-0" FAMILY ROOM #1 SERVICE MANAGER FAMILY ROOM #2 SALES MANAGER 6j-.11 7/8" SALES CENTER 4'-0" ■ EMP. TOILET 8'-0" (E BUSINESS CENTER 7.0 • N) w -J IT / METER / • STORAGE w 1406 Pr) 0 -11: 1 /2" "7'-11 5/16" (E) (E) KEY \OTES: 1. EXISTING TENANT DEMISING WALL TO REMAIN AS SHOWN EXISTING STOREFRONT SYSTEM TO REMAIN - NO CHANGES EXISTING ACCESSIBLE TOILET ROOM, FINISHES AND. FIXTURES TO REMAIN - NO CHANGES • EXISTING ELECTRICAL PANEL LOCATION TO REMAIN UNCHANGED. ELECTRICAL SUBCONTRACTOR TO SUBMIT SEPARATELY FOR ELECTRICAL PERMIT FOR WORK ON THIS PROJECT. ELECTRICAL OUTLETS ARE SHOWN • FOR SPACE PLANNING REFERENCE ONLY (TYPICAL). ELECTRICAL SUBCONTRACTOR TO SUBMIT SEPARATELY FOR ELECTRICAL PERMIT FOR WORK ON THIS PROJECT. DATA OUTLETS ARE SHOWN FOR SPACE PLANNING I EFERENCE ONLY (TYPICAL). TENANT TO COORDINATE LOCATION WITH ELECTRICAL SUBCONTRACTOR. ALL FLOOR AREAS SHOW TO RECEIVE CARPETING UNLESS NOTED OR SHOWN OTHERWISE. 8'=0" WIDE X 6'-0" DEEP AREA (CTR ON DOORS) W/ 12' X 12" CERAMIC TILE (DALTILE HEATHLAND COLOR: ASHLAND) TYPICAL INTERIOR FRAMED PARTITION: 3-5/8" 35 GA. METAL STUD © 24 O.C. W/ /8" GWB EACH SIDE;. 3 Y2" SOUND BATT INSULATION © OFFICE AND RESTROOM WALLS (TYPICAL UNLESS NOTED OR SHOWN OTHERWISE) 10. TYPICAL INTERIOR DOOR: 3'-0" X 7-0" X 1 %" SOLID CORE, PAINT GRADE (COLOR TO MATCH ADJACENT WALL PAINT) IN 18GA HM FRAMES 11. OVERHEAD CABINETS WITH MICROWAVE OVEN SHELF 12. SS BAR SINK. PLUMBING SUBCONTRACTOR TO SUBMIT SEPARATELY FOR PLUMBING PERMIT FOR. WORK ON THIS PROJECT 13. 36" TALL BASE CABINETS 14. REFRIGERATOR (BY TENANT) 15. EXISTING SUSPENDED ACOUSTIC CEILING TO REMAIN - GC TO REMOVE TILES, PAINT AND REPAIR GRID AS REQUIRED AND INSTALL NEW 2'X4' TILES (ARMSTRONG DUNE 1777, COLOR WHITE) 16. RELOCATE EXISTING 2'X4' FLUOR. TROFFER FIXTURES AS SHOWN - RELAMP AS REQUIRED TO INCLUDE (3) 32W T8 LAMPS EACH FIXTURE 17. EQUIPMENT/FIXTURE BY TENANT 18. 42" WIDE . X 78" HIGH RELITE IN PAINTED WOOD FRAMES Y" CLEAR TEMPERED GLASS; ALIGN TOP EDGE OF RELITE WITH TOP EDGE OF ADJACENT DOOR. TYP. AS SHOWN. 19. 24" DEEP COUNTERTOP MOUNTED AT 36" A.F.F.; SUPPORT WITH SINGLE CENTERED DIVIDER. FELE COPY Permit No. V' 11' 006O Plan review approval is subject to errors and omissions. ;�••., ..,., J of construction documents does not authorize any adopted code or ordinance. Receipt &proved Fib Copy and conditions is acknowledged: REVIEWED FOR CODE COMPLIANCE APPROVED MAR 14 2014 City of Tukwila BUILDING DIVISION I By Z V Date: 0--,/�/:964/ M City Of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 1 0 2014 PERMIT CENTER L_ 00 i- F- LU U 0 w z w z w nDATE REMARKS BY - 03/03/14 PERMIT SUBMITTAL . . ,, , PLEASE CONSIDER THE ENVIRONMENT BEFORE PRINTING THIS DRAWING 4 4 ,,, 4 Ll•- 00 60 DRAWN BY: GBB CHECKED BY: GBB JOB #: 14-01047 DATE: 03/03/14 • SHEET #: L_ M1. 1