Loading...
HomeMy WebLinkAboutPermit M14-0061 - 9-110 BR&T STORAGE - HOOD, FAN, LOUVER AND DUCTWORKBOEING #9-1O1 BR&T STORAGE 9725 EAST MARGINAL WAY S M14-0061 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No: 0003400018 Permit Number: M14-0061 Address: 9725 E MARGINAL WAY S BLDG 9- Issue Date: 3/24/2014 110 Permit Expires On: 9/20/2014 Project Name: BOEING #9-110 - BR&T STORAGE Owner: Name: BOEING COMPANY THE Address: PO BOX 3707 M/C 20-00 PROPERTY TAX DEPT, SEATTLE, WA, 98124 Contact Person: Name: CONNIE HARDIN Address: 4600 S 134TH PL, SEATTLE, WA, 98168 Contractor: Name: HOLADAY PARKS, INC. Address: PO BOX 69208 , SEATTLE, WA, 98188 License No: HOLADP1379NO Lender: Name: Address: Phone: (206) 250-4530 Phone: (206) 248-9700 Expiration Date: 9/3/2015 DESCRIPTION OF WORK: ADD 1 HOOD AND FAN, 1 LOUVER, ASSOCIATED DUCTWORK. Valuation of Work: $5,000.00 Type of Work: Fuel type: Fees Collected: $258.96 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer Distric: TUKWILA SEWER SERVICE,VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2012 2012 Permit Center Authorized Signature: CJ.:(0,- Date: J _)-11"—{ I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and gree to the conditions attached to this permit. Signature: . c� Date: 'T —( C ( Print Name: I I". i Guf—c c v� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 4: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 5: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ***MECHANICAL PERMIT CONDITIONS*** 11: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 12: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWA. 1 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** King Co Assessor's Tax No.:1 OD3Wt y 7 Site Address:RI ZS /1� ` ��11 �j.-4W ` i Qum` Suite Number: Floor: Tenant Nameq a-4T 5 , >C New Tenant: ❑ Yes Name: ID viD .t Lib Addres%Dlt b7 11n. (n 20bb City e (J tate:.. ^� Zipetict Name: -. �wk t Ocarlt �- Address: t bb City; Phone: State: Zip (O F Pet-ekS Address:460o S t 3 p.Q Company Name: City: State Zipesa Phonemr to gsa)Fax: i Aier zqj - " Contr Reg No.: Exp Dat t.lev:bP I Ile/ ► 0 Tukwila Business License No.: 'Wit Z, cN4 (J ax: T.0 6 Z, g v" 766 Email: ! - 11, 04.0‘,/tAat,,,Asi.. Valuation of project (contractor's bid price): $ SDO. Describe the scope of work in detail: f lusa', `Qa" ( `bt) ✓G% Q �K�IGC� /J &Lebo' elk • Use: Residential: New El Replacement ❑ Com-.-'... mere a New ❑ Replacement ❑ Fuel Type` Electric ❑ Gas ❑ Other: 1i \Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised- August 2011 bh Page I of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qiy Furnace <1 OOk btu Furnace > I00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <I0,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct f Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Loove r' aciszew:61 Auk Boiter/Compressor, Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERM°. Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR'1'IIIS PERMIT. BUILDINGENT: Signature: Day Telephone: Mailing Address:14ov S t'I i e /-)ealt1/4. City Date: V L 2-s'o 44S- 106/ 4116� State Zip H.\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11. docx Revised August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $258.96 M14-0061 Address: 9725 E MARGINAL WAY S BLDG 9-110 Apn: 0003400018 $258.96 MECHANICAL $249.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $166.70 PLAN CHECK FEE R000.322.102.00.00 $49.80 TECHNOLOGY FEE $9.96 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R1452 R000.322.900.04.00 $9.96 $258.96 Date Paid: Wednesday, March 12, 2014 Paid By: HOLADAY PARKS Pay Method: CREDIT CARD 02241G Printed: Wednesday, March 12, 2014 2:57 PM 1 of 1 CRWSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION C 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 /1 Permit Inspection Request Line (206) 431-2451 Project: . I.0 '� i — /(© Typeof Inspection: vil64 1--IJ Ake Add es.�: �t i'LD - M (p.'idA-L Date Called:_,, a fl! -L - Spa-?clf ,a m, ,�., p.m. Special Instructions: g2 A. T-S`T\)fikl1-- i Lot FAA/1 p `1 C"„Wrkk Date Wanted , 3 r 4 Requester ii' f Q Phone No: Approved per applicable codes. EJ Corrections required prior to approval. COMMENTS: %pl:,117) Inspector: P kti Date:1 — 3 REINSPECTION FEE REWIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0061 DATE: 03/12/14 PROJECT NAME: BOEING #9-110 - BR&T STORAGE SITE ADDRESS: 9725 EAST MARGINAL WAY S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: A/1juci3`G-1 Building Division IN Public Works AtIA Fire Prevention nu Structural Planning Division Permit Coordinator n 1 PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 03/13/14 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: DUE DATE: 04/10/14 Approved with Conditions n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 HOLADAY PARKS INC Page 1 of 4 Mk Washington State Departinent of Labor & Industries HOLADAY PARKS INC Owner or tradesperson PARKS, GERALD T JR Principals PARKS, GERALD T JR NAILON, JUNE ANNETTE O'CONNOR, BONNY K BECK, DAVID CLARENCE VAN DER VEEN, ERIC M (End: 08/14/2013) PIZZEY, GRACE KATHERINE (End: 08/14/2013) VAN DER VEEN, JULIE ELIZABETH (End: 08/14/2013) CONNELL, DANIEL AARON (End: 08/14/2013) GIRI, BUIT (End: 08/14/2013) KIEL, RINALD HOWARD (End: 08/14/2013) WHITMYRE, CHRISTIAN (End: 08/14/2013) NELSON, MICHAEL (End: 11/04/2010) PARKS, DAVID L (End: 11/04/2010) TALBOT, PAUL (End: 11/04/2010) Doing business as HOLADAY PARKS INC WA UBI No. 578 004 089 4600 S 134TH PL SEATTLE, WA98168 206-248-9700 KING County Business type Corporation Governing persons License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. HOLADPI379NO Effective — expiration 01 /21 /1983 — 09/03/2015 Bond LIBERTY MUTUAL INS CO Bond account no. 23000452 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 08/23/2002 09/01/2002 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379N0&SAW= 03/24/2014 CODES AND PERMITS THE nfiEviviV&P COMPANY SUPPORT SERVICES GROUP 9-110 BUILDING - BR&T STORAGE BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 VICINITY MAP PROJECT WORK LOCATION OXBOW PARKING LOT DEVELOPMENTAL CENTER NO SCALE CODE SUMMARY TYPE OF APPLICATION: ['NEW ❑ ALTERATION ❑ ADDITION ®TENANT IMPROVEMENT PROJECT DESCRIPTION: TO INSTALL AND ANCHOR (12) PALLET RACKS. PROVIDE FAN, LOUVERS AND DUCTWORK. PROVIDE SPRINKLER MODIFICATIONS. PROVIDE MISC. ELECTRICAL POWER AND CONTROLS. CODES: 20 2 INTERNATIONAL BUILDING CODE & WAC 51-50 20 2 INTERNATIONAL MECHANICAL CODE & WAC 51-52 20 2 INTERNATIONAL FIRE CODE & WAC 51-54 20 2 UNIFORM PLUMBING CODE & WAC 51-56 20 2 UNIFORM PLUMBING CODE AMENDMENTS A, B & I & WAC 51-57 2008 NATIONAL ELECTRIC CODE, AMENDMENTS A, B & C & WAC 296-46B-010 2012 WASHINGTON STATE ENERGY CODE WAC 51-11 CURRENT CITY OF TUKWILA ZONING ORDINANCES CONTRACTOR & STATE NUMBER BOEING PROJECT ENGINEER: PROJECT DESIGNER/ARCHITECT :DOUGLAS CONDIT/EISI PHONE: 206-284-1181 BOEING CONTACT. JOHN MURDOCH FAX NUMBER. 253-773-0119 E-MAIL john•s•murdoch@boeinq.com OCCUPANCY GROUP. GROUP B - OFFICE CONSTRUCTION TYPE. TYPE VN SEPARATION 60 FEET (MINIMUM THREE SIDES) ZONING.ALLOWABLE AREA INCREASE. SPRINKLERED & 60' SET -BACK (NO CHANGES) THE BOEING CO. BOEINC * 294ML ( OV2009 ) PHONE 253-773-0444 OCCUPANT LOAD: (ALLOWABLE) NO CHANGE FLOOR AREA: (ACTUAL) NO CHANGE (TABLE 10—A) OFFICES OCC BLDG GROSS 8,636 PROJECT AREA 2,900 SQ FT SQ FT BUILDING HEIGHT: (ACTUAI)I8 FT STORIES: 1 MEZZANINE ?❑ (YES) II (NO) SQ FT FIRE PROTECTION: SPRINKLERED THROUGHOUT PER NFPA 13 ? ® (YES) ❑ (NO) SEPARATION EXTERIOR WALL (NON —BEARING) HOUR RATING EXTTERIOR WALL (BEARING) HOUR RATING INTERIOR WALL (NON —BEARING) HOUR RATING INTERIOR WALL (BEARING) HOUR RATING DEMOUNTABLE PARTITIONS HOUR RATING STRUCTURAL FRAME HOUR RATING FLOOR/CEILINGS HOUR RATING ROOF CONSTRUCTION HOUR RATING SEISMIC DESIGN: ZONE D DESIGN LOADS: (CHAPTER 16) ROOF: LIVE (SNOW) (PSF) FLOOR: OFFICE (PSF) MECH/STOR (PSF) STAIRS (PSF) CONCENTRATED. WIND: EXPOSURE 80 MPH, EXPOSURE C SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ORIGINAL ISSUE 20368-10 EISI GMM 01.15.14 BOE/A/G' - IFC GENERAL NOTES A CONSTRUCTION SET OF DOCUMENTS, BUILDING DEPARTMENT MUST CONSTRUCTION WITHOUT ABOVE 1. THE GENERAL CONTRACTOR DIMENSIONS AND CONDITIONS BEFORE COMMENCING ANY WORK VARIOUS TRADES MEETS APPROPRIATELY. ON THE DRAWINGS OR SPECIFICATIONS CONSTRUCTION MANAGER IMMEDIATELY REVISIONS. 2. COORDINATE THE WORK AND ELECTRICAL DRAWINGS IN REQUIREMENTS. COORDINATE EQUIPMENT FURNISHED BY CONTRACTOR 3. ASBESTOS NOTIFICATION: CONDUCTED AND ASBESTOS REMOVED PRIOR TO THE BEGINNING REPORT OF THE SURVEY WILL OR NEGOTIATIONS. DO NOT ADJACENT TO THE WORK AREA. CONTAINING MATERIAL IS DISCOVERED SUPPORT THE WORK OF THIS 4. THE GENERAL CONTRACTOR CONSTRUCTION DOCUMENTS DAILY WITH ANY ACTUAL WORK DOCUMENTS. SAID SET SHALL PROJECT MANAGER AT THE COMPLETION RECORD DOCUMENTS. DRAWING BE ON MENTIONED SHALL SHOWN AND OF ALL DETAIL ALL ROUGH A GOOD CONTAINING BE FURNISHED REMOVE, CONTACT PROJECT. SHALL ON SITE. OR INSTALLATIONS BE TURNED REVIEWED AND STAMPED BY THE CITY OF TUKWILA SITE DURING CONSTRUCTION. DO NOT PROCEED WITH SET OF DOCUMENTS. VISIT THE SITE AND VERIFY ALL EXISTING ON THE DRAWINGS WITHIN THE AREA OF WORK ENSURE THAT THE JOINING OF THE WORK OF THE CONTRACTOR SHALL BRING DISCREPANCIES TO THE ATTENTION OF THE BOEING PROJECT UPON DISCOVERY ONLY IF THEY REQUIRE DESIGN TRADES. REFER TO ARCHITECTURAL, MECHANICAL FOR COORDINATION OF SPECIFIC TRADE -IN REQUIREMENTS FOR MATERIALS OR OR BY OTHERS FOR THIS PROJECT. FAITH SURVEY OF THE WORK AREA HAS BEEN MATERIAL WAS NOT DISCOVERED OR WILL BE OF THE WORK FOR THIS PROJECT. A COPY OF THE TO THE CONTRACTOR AT THE TIME OF BIDDING DAMAGE OR DISTURB ANY ASBESTOS MATERIAL BOEING FACILITIES DEPARTMENT IF ASBESTOS OR DAMAGED THAT IS REQUIRED TO BE REMOVED TO OBTAIN AND MAINTAIN A FULL SET OF THIS SET SHALL BE MARKED UP (RED -LINED) DIFFERING FROM THE CONSTRUCTION OVER TO THE BOEING CONSTRUCTION OF THE WORK FOR INCORPORATION INTO BOEING INDEX ARCHITECTURAL - CIVIL DRAWING NUMBER REV DRAWING TITLE 09-110—AO NEW COVER SHEET 09-110-1 Al OR R FLOOR PLAN — REMOVALS 09-110-1A01 B FIRST FLOOR EXITING PLAN 09-110-1 A10 E FLOOR PLAN 09-110—A503 NEW SECTIONS & DETAILS STRUCTURAL DRAWING NUMBER REV DRAWING TITLE 09-110—S505 NEW PALLET RACK ELEVATIONS ---- - ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED ROVED BY DEPT. DATE DRAWN DATE CHECKED ENCI N1=EH CHECKED SUBTITLE PROJECT TITLE: 9-110 BR&T STORAGE JOB NUMBER: 20368-10 QUANTITY SUBMITTED: ❑ 5 SETS: GENERAL PERMIT (SHELL & CORE) OR STRUCTURAL TENANT ® 4 SETS: TENANT IMPROVEMENT (NON-STRUCTURAL) ❑ 3 SETS: FIRE PROTECTION/SPRINKLERS ❑ 2 SETS: TENANT IMPROVEMENT (REVISION) SUBMITTED FOR PERMIT & REVIEW: ❑ BUILDING ❑ PLUMBING MECHANICAL* II STRUCTURAL ❑ GRADING ❑ LANDSCAPE ❑ DEMOLITION ❑ - *TO BE REVIEWED UNDER SEPARATE PERMIT WASHINGTON STATE NON-RESIDENTIAL ENERGY CODE -APPROACHES COMPLIANCE OPTION ❑ PRESCRIPTIVE ❑ LPA ❑ ANALYSIS MI N/A SPECIAL INSPECTIONS REQUIRED: ❑ WELD ❑ REBAR ❑ STRUCTURAL BOLTING ❑ OTHER CALCULATIONS TYPE • N/A IMPROVEMENT ❑ ELECTRICAL CIE ❑ FIRE PROTECTION* ❑ CANTILEVER RACKS - ❑ CONCRETE ANCHOR BOLTS ❑ STRUCTURAL OBSERVATION ATTACHED (YES) (NO) DRAWING INDEX MECHANICAL DRAWING NUMBER REV DRAWING TITLE 09-110-1M1OR 09-110-1M10 D D HVAC FIRST FLOOR PLAN (REMOVALS) HVAC FIRST FLOOR PLAN 09-110-1 M260 C FLOOR PLAN 09-110-1 M500 NEW EXHAUST HOOD DETAILS SEPARATE PERMIT REQUIRED FOR 0 mecnarncau C�?lec��ica! C'lumbing riaas Piping City of Tukwila 130,p'NO DIVISION ELECTRICAL DRAWING NUMBER REV DRAWING TITLE 09-110-1 E6OR 120/208V AC PLAN — REMOVALS 09-110-1 E110R 09-110-1 E60 C 277/480V AC PLAN — REMOVALS 120/208V AC PLAN 09-110-1 E110 C 277/480V AC PLAN 09 —110-1 E501 NEW MISCELLANEOUS DETAILS REVISIONS No changes shalt be made to teem of work without prior approval of Tukwila Building Division. IUQT6. evisiol is will require a new plan submittal mad may inch utf r Ian reviow Ices. CITY OF TUKWILA BLANKET PERMIT AGREEMENT NUMBER: 12-001-BPA FILE C Permit No. M114 o1, Play roview approval is subject to errors and omissions. of co truction documents does not authorize any p.dopted code or ordinance. Receipt PY anis acknowledged: Lppro/ By Date: ,,Zr c q H L� City Of Tukwila BUILDING DIVISION Mtoc&I rVIEWED FOR E COMPLIANCE PPROVED AR 2 0 2014 � la Tukwila ofTING DIVISION RECEIVED CITY OF TUKWILA MAR 12' 2014 PERMIT CENTER PROJECT TITLE ;BR&T STORAGE #20368-10 COVER SHEET CURRENT REVISION 20368-10 SYMBOL0 SIG DATE 01.15.14 APPROVED APPROVED TITLE PERMIT MASTER BR&T STORAGE BUILDING 09-110 DEV. CENTER, WA SHEET AO JOB NO. 20368-10 COMP NO. DWG NO. 09 -110-AO 0 LECE\D SYM REVISION T RACK 40X123 satxo* >13V 1311Vd PALLET RACK BY 40X123 APPROVED PALLET 11 RACK 40X123 DATE SYM -o 0 FRIEDRICH FLOATING AIR REVISION PALLET RAE< PALLET 'ACK ;1 CFM (TYP 3) 11 40X123 920 CFM D D n '£ZI.XOi' .,-,. Ot >ICbd 1 r, 1311Vd AEL 80 ®CFM 280 240 CFM Ezi CI CFM 80 13 BY 24/12 )20 CFM 270 CFM 230 CFM 10 8 PI FNUM 25'—O" LONG (TYP 2) AiOk v B B, 700 CFM (TYP 2) 700 CFM 100 CFM 220 CFM APPROVED 300 CFM DATE CO N A IR SIGNATURE LAB J#190105-02 CH/KB 9.20.00 B IR SIGNATURE LAB (CODE REVISION) J#190105-02 CH 10-31-00 C INSTALL CEILING DIFFUSER J#120706-02 DMV RWS 10.30.02 D RELOCATE BR&T STORAGE J#20368-10 EISI MW 10.30.13 300 CFM 12 270 CFM N 100 300 CFM 22/16 10/8 v 0/8 54/16 RA 108/016 RA v ON ROOF 270 TOP OF GRILLE CFM IN CONFERENCE ROOM IS 7' 0” AFF BOTTOM OF RILLE IN OPEN OFF CE AREA IS 1'—:" AFF CFM 120 CFM CFM g)LAOE/NG" I FIRST FLOC PLA\ SCALE: 1 /8"=1'-0" RR 250 CFM 280 CFM 280 CFM � r 30x18, 30x24 HI & LOW LOUVER (2 PLACES) ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN K.BUN 250 CFM 90 CFM 90 CFM DATE 9.20.00 CHECKED C.HARRAH ENGINEER CHECKED 9.20.00 SUBTITLE 300 CFM CFM\L. 190 CFM DUCT SIZE 13 / 14 IFC HVAC FIRST FLOOR PLAN RECTANGULAR DUCT, FIRST NUMBER INDICATES SIZE FOR SIDE SHOWN 20/12-Ththu DUCT SHOWN IN SECTION, ARROW POINTS TO SIDE CALLED OUT FIRST 200 200 E ROUND DUCT, NUMBER INDICATES DIAMETER LINED DUCT FLEXIBLE DUCT LINEAR DIFFUSER AND CFM AIR FLOW RETURN/RELIEF GRILLE, CEILING TYPE UNIT HEATER, HORIZONTAL THERMOSTAT T NOTES EXHAUST FAN MANUFACTURER: NEW YORK BLOWER MODEL: COMPACT GI SIZE: 95 ARRANGEMENT: 4 — DIRECT DRIVE DISCHARGE: TOP HORIZONTAL WHEEL MATERIAL: ALUMINUM MOTOR: 1/2 HP 120V, 60 CYCLE, SINGLE PHASE PERFORMANCE: 150 CFM AT 1.15" STATIC PRESSURE SPEED: 1740 RPM, POWER: 0.163 HP FAN AND DAMPERS TO BE INTERLOCKED WITH THE BATTERY CHARGING EQUIPMENT. GE \HAL OTES 2. RETURN AIR DUCT TO BE INSTALLED AS HIGH AS POSSIBLE WITH TOP OF DUCT HEIGHT TO BOTTOM ON ROOF STRUCTURE. SUPPLY AIR DUCTS TO BE INSTALLED BENEATH RETURN AIR DUCTS. CARE SHOULD BE TAKEN TO AVOID EXISTING SPRINKLER SYSTEM. 3. ALL RETURN AIR DUCTS ARE ACOUSTICALLY LINED, AND ALL SUPPLY AIR DUCTS FROM THE OUTLET OF AHU-1 TO THE TERMINAL BOXES ARE ACOUSTICALLY LINED. SEE SPECIFICATIONS SHEET M2. 4. DUCT SIZES ARE CLEAR INSIDE DIMENSIONS. 5. THE SIZE OF DUCTS TO INDIVIDUAL DIFFUSERS SHALL BE THE SAME SIZE AS THE INLET/NECK SIZE INDICATED ON THE SCHEDULE SHEET M3 UNLESS OTHERWISE NOTED. 6. FOR DETAIL OF TRANSFER AIR DUCTS. SEE DETAIL M-4 M-6 7. RIGID DUCTS DOWNSTREAM OF VAV TERMINAL BOXES TO BE SAME SIZE AS VAV TERMINAL BOX OUTLET UNLESS OTHERWISE NOTED. MINIMUM HEIGHT OF RIGID DUCTS DOWNSTREAM OF FA—X BOXES TO BE 10" 8. ALL LINEAR SLOT DIFFUSER TO BE TYPE LD-1 UNLESS OTHERWISE NOTED. 9. ALL RETURN AIR GRILLES TO BE TYPE RG-1 UNLESS OTHERWISE NOTED. 10. THIS MECHANICAL PLAN WAS COMPLETED PRIOR TO THE COMPLETION OF DRAWING E10, LIGHTING PLAN. THE RELOCATION OF RETURN GRILLES 2'-0" IN ANY DIRECTION TO AVOID INTERFERENCES WITH LIGHTING IS PERMISSIBLE. 11. THE TWO EXISTING 12/12 PENETRATIONS IN THE TOP OF THE CONFERENCE ROOM (PREVIOUSLY THE VAULT) ARE TO BE USED FOR NEW DISTRIBUTION DUCTWORK. 12. RELOCATE GAS WATER HEATER AND TIE—IN GAS, COLD WATER, AND HOT WATER PIPING AND VENT INTO EXISTING SERVICES. CO\S-RUCTIO \ NOTES PROVIDE A WELDED STEEL EXHAUST HOOD WITH STRIP CURTAINS ON THREE SIDES, OVER THE BATTERY CHARGING AREA. HOOD SHALL BE SEALED AIR TIGHT. PAINT THE HOOD USING ONE COAT OF PRIMER ON ONE FINISH COAT OF ALKD ENAMEL. COORDINATE WITH CONSTRUCTION MANAGER REGARDING COLOR. SUPPORT THE HOOD FROM THE ROOF FRAMING AS SHOWN. BOLT THE CURTAINS TO THE INSIDE OF THE HOOD USING CURTAIN VENDOR HARDWARE. PROVIDE A HYDROGEN EXHAUST FAN. SUPPORT THE FAN FROM STRUT BOLTED TO THE TOP OF THE HOOD. COORDINATE WITH ELECTRICAL TO INTERLOCK THE EXHAUST FAN AND BACKDRAFT DAMPERS WITH THE BATTERY CHARGING EQUIPMENT. THE FAN SHALL RUN WHEN THE CHARGING EQUIPMENT IS IN USE. PROVIDE A 24" X 24" LOUVERED AIR INLET AND MOTORIZED DAMPER WITH A WALL SLEEVE. DAMPER MOTOR SHALL BE 120V, SINGLE PHASE SEE ARCHITECTURAL DRAWING 09-110—A503. BOLT THE DUCT SLEEVE TO THE GIRT USING ANGLE CLIPS. COORDINATE WITH ELECTRICAL TO INTERLOCK THE INLET DAMPER WITH THE BATTERY CHARGING EQUIPMENT. SEE ARCHITECTURAL FOR WALL PENETRATION WEATHERPROOFING REVIEWED FOR 'CODE COMPLIANCE APPROVED MAR 2 0 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 12 2014 PERMIT CENTER CURRENT REVISION 20368-10 SYMBOL D DATE 01.15.14 APPROVED APPROVED TITLE MECHANICAL MASTER RELOCATE BR&T STORAGE BUILDING 9-110 COL. A-DD / 1-4L D.C. SHEET 1M10 JOB NO. J#190105-02 COMP NO. DWG NO. 9-110-1M10 LECE\D ,SYM REVISION M500 61\.f 6" 0 DUCT 1 /2" 0 BOLTS THRU HOOD (4 PLACES) STRUT FAN SUPPORT TRANSITION AT FAN OUTLET 6'-0" BLDG. COLUMN (REF.) 14 GA. 6'-0'x6'-0" WELDED STEEL HOOD 2 6" 0 622A STRUT DETAIL SCALE: 1/2 =1'- BEAM CLAMP (TYP.) B441-22A B22A 6" 0 BUTTERFLY STYLE MANUAL BALANCING DAMPER WITH LOCKING QUADRANT, AT CONNECTION TO HOOD 1 /2"0 ATR EXHAUST FAN " 1 1M10 M500 >—<CONT, TYP 3 M500 CLEAR PVC STRIP CURTAIN ON THREE SIDES BIRD SCREEN B22A STRUT 1 /2" 0 BOLT (2)-1/2'0 LINDADAPTOR HB HOLLO BOLTS © 2 1/2' MOTORIZED BUTTERFLY DAMPER IN DISCHARGE, AT THE WALL 4 M500 BUILDING SIDING 7 (REF.) BY APPROVED SECTIC\ SCALE: 1 /2"=1'-0" DATE SYM A 1M10IM500 REVISION BY APPROVED DETAIL SCALE: 1 1 /2"=1'-0" DATE RELOCATE BR&T STORAGE J#20368-10 EISI MW 10.30.13 HOOD L 3x3x1 /4x0'-5" L 2x2x3/16x0'-3" HSS 1 /8 (2)-3/8" 0 BOLTS 1/8 2 M500 DETAIL SCALE: 1 1/2"=1'-0" M500 DETAIL SCALE: 1 1 /2"=1'-0" ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN EISI HOOD L 2x2x3/16x0'-4" B22A STRUT DATE 12.12.13 (4� M500 CHECKED CAS ENCINEER CHECKED APPROVED APPROVED 12.12.13 SUBTITLE TITLE MECHANICAL MASTER GENERAL \OTES CONSTUCTIO\ NOTES PROVIDE LATERAL BRACING FOR THE HOOD BY BOLTING THE HOOD TO STRUT INSTALLED HORIZONTALLY BETWEEN COLUMNS AT THE ELEVATION OF THE BOTTOM OF THE STEEL HOOD. BOLT IN TWO PLACES NEAR THE CORNERS OF HOOD. PROVIDE DUCTING FROM THE HOOD TO THE FAN AND FAN TO OUTSIDE INCLUDING BALANCING DAMPER AT THE HOOD AND MOTORIZED BACKDRAFT DAMPER AT THE WALL PENETRATION. DAMPER MOTOR SHALL BE 120V, SINGLE PHASE. SEE ARCHITECTURAL FOR WALL PENETRATION WEATHERPROOFING. DUCTING SHALL BE GALVANIZED STEEL AND COMPLY WITH ASHRAE HVAC DUCT CONSTRUCTION STANDARDS. SEAL FAN DISCHARGE DUCTING FOR + 1" STATIC PRESSURE SERVICE USING DUCTMATE PROSEAL OR EQUAL. IFC tellq•-606)( EXHAUST HOOD DETAILS RELOCATE BR&T STORAGE BUILDING 9-110 COL. A-DD / 1-4L D.C. CURRENT REVISION 20368-10 REVIEWED FOR CODE COMPLIANCE APPROVED MAR 20 2014 City of Tukwila BUILDING DIVISION SYMBOL° RECEIVED CITY OF TUKvVt,LA MAR 1 2.2014 PERMIT CENTER SIG DATE 01.15.14 SHEET M500 JOB NO. J#20368-10 COMP NO. DWG NO. 9-110-M500