HomeMy WebLinkAboutPermit M14-0067 - CHIPOTLE MEXICAN GRILL - REFRIGERATION SYSTEMCHIPOTLE MEXICAN GRILL 2600 SOUTHCENTER MALL FC-02 M14-0067 Parcel No: Address: Citv of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gpv MECHANICAL PERMIT 9202470010 Permit Number: M14-0067 2600 SOUTHCENTER MALL FCO2 Issue Date: 3/26/2014 Permit Expires On: 9/22/2014 Project Name: CHIPOTLE MEXICAN GRILL Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, WA, 92013 GREG EDWARDS 4403 LAKESHORE DR , MOSES LAKE, WA, 98837 ERICKSON REFRIGERATION LLC Phone: (206) 510-3458 Phone: (253) 333-7294 1519 W VALLEY HWY N STE 102, AUBURN, WA, 98001 ERICKRL922QE Expiration Date: 3/21/2016 DESCRIPTION OF WORK: INSTALL PRE -PRESSURIZED REFRIGERATION LINES FROMW ALK IN COOLER TO ROOFTOP CONDENSER. ALSO INSTALL PRE -PRESSURIZED REFRIGERATION LINES FROM ICE MACHINE TO ROOFTOP CONDENSER. Valuation of Work: $3,000.00 Type of Work: NEW Fuel type: GAS Fees Collected: $188.90 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer Distric: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: Permit Center Authorized Signature:1 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Date: 02 2-(1 H I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit d state or local laws regula development permit and of presume to give authority to violate or cancel the provisions of any other truction or the performance of work. I am authorized to sign and obtain this the conns atiached to this permit. Signature: Date: 3 - 0.26 / Y Print Name: eJ 7c/Lw Ird 5 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***MECHANICAL PERMIT CONDITIONS*** 2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 7: Type 1 Hoods, the required grease duct leakage test and flight test shall be performed by a special inspection and testing agency in accordance with I.M.C. Chapter 5. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWI Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 littp://www.TukwilaWA.gov Mechanical Permit No. Pq14- Ni 1 Project No. pp�� Date Application Accepted: V ut Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION cu � Potle Site Address: 9.600 Soak 62N,t(I%'. bar King Co Assessor's Tax No.: 7/-19`4 ` BOO 1.0 1 Suite Number:C0� Floor: Tenant Name: oilpo ' t2. (vi -�c�� r+ r, {(New Tenant: ❑ Yes ❑.. No PROPERTY OWNER Name: Wt-(.,Th up Address: Q 0 IboNi v2,30 /f1 Go YJ _cipt! City: ,Mr State: Ci Zip:16 CONTACT PERSON — person receiving all project communication Name: 6 c)2 Address: tL0'S 1.ette4eYie. kA Zip:R City: it'lles 14$L( State:WA- �7 Phone: az(2- S 0-3HS5l 955-((333 - i -7`� a m((Fa� Eai t ., . i Pattl-t u& , ('Uk'\ MECHANICAL CONTRACTOR INFORMATION Company Name: ftl[k6cm p eN _ -' (M V + 1L Address: too CJ (AkeDr City:s wicl State: Zip:132 Phone _78. /7» Fax:j,s_3"53.3_/7S9.,_ Contr Reg No.: Exp Date: Tukwila Business License No.: c - Srl Difi Valuation of project (contractor's bid price): $ 31 COO •°° Describe the scope of work in detail: L'A.41vrg,.$) Pz-C " PtS<hUt' ONAM.Del VIA42'S dt,' t'An � i'vcx % �tn�o)-e,,t' . 4'ip 1. vt Still ✓� 1 e \ l C r \ � fi+ wse t • �n gfeArt .xM -("t% hU& p Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement ❑ Fuel Type: Electric ❑ Gas ❑ Other: H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page I of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heatlrefrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY TU -t WS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR iZHORIZE Signature: Date: alP Print Name: 6fEed c< T _5 Day Telephone: 7 L/C2S Mailing Address: g140 Lc) bAz di2AZ,�(- 1f %eS (At (.Cdlf" q,3 7 City State Zip H:WpplicationsWorms-Applications On Line\201 I Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 DESCRIPTIONS PermitTRAK Cash Register Receipt City of Tukwila ACCOUNT QUANTITY I PAID $188.90 M14-0067 Address: 2600 SOUTHCENTER MALL FCO2'+ Apn: 9202470010 $188.90 MECHANICAL $179.90 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $147.40 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R1595 R000.322.900.04.00 $9.00 $188.90 Date Paid: Wednesday, March 26, 2014 Paid By: ERICKSON REFRIGERATION, GREGOR Pay Method: CREDIT CARD 07520G Printed: Wednesday, March 26, 2014 10:52 AM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit 1' `�`�& f.1 INSPECTION NO. PERMIT NO. , A CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: / � t / -'{ t , p ,,) t/� - Jt [ (n Ex c. l i / Type of trspection: �/i e(J . D J 6 f A Address: ?(,)o0 C M i Date Called: Meng Ai4L- Special Instructions: Date Wanted: - Z �� `_m. a.m. p.m. Requester: Phone No: Approved per applicable codes. • Corrections required prior to`approval. COMMENTS: Leif ,t fs,>r7�Prt ,z7,/ Inspettor Date: a .06 AA REINSPECTION FEE REQUIRED! Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. M1 -d06'1 CITY OF TUKWILA BUILDING DIVISION G 6300 Southcenter Blvd., 4100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Type of nspe Addre Sc Date Special Instructions: Date Wanted: Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: REINSPECTION FEE REQUIRED. for to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Report By: National TAB 9471 Sutton Place Hamilton, OH 45011 11tA -ocui NATIONAL • T B Report: Test and Balance Date: 4/1/2014 PROJECT Chipotle - Southcenter Mall #2270 633 Southcenter Mall, 2600 Tukwila, WA 98188 Client Chipotle Mexican Grill 1401 Wynkoop Street, Suite 500 Denver, CO 80202 Powered by FAC1I1BUIID www.facilibuild.com National TAB Project: Chipotle - Southcenter Mall #2270 Table Of Contents Section Page # Summary Data 3 Checklist Data 4 AHU/RTU 9 FAN - Exhaust 11 FAN - Supply 13 Kitchen Hood Type I 14 Kitchen Hood Type II 15 Powered by FaciliBuild! Date: 4/1/2014 Page 2 of 15 www.facilibuild.com National TAB Project: Chipotle - Southcenter Mall #2270 Project Summary OUTSIDE AIR IS DUCTED TO THE ROOF USING A CIRCULAR DUCT WITH CAPTIVE AIRE ROOF CAP. THE TOTAL AHU FLOW IS LOWER THAN DESIGN. THE UNIT THERMOSTAT WAS SET TO 55 DEGREES, TO ESTABLISH FULL COOL BALANCE POINT. THE UNIT WAS THEN INITIALLY READ AND WAS SUPPLYING 1675 CFM. THE RETURN DUCT WAS REDUCED TO FORCE A GREATER PERCENT OF OUTDOOR AIR THROUGH THE OA DUCTED SYSTEM. THE BALANCE, RESTRICTION OF DAMPERS, RESULTED IN A FINAL VOLUME OF 1,595 CFM WHILE THE OUTDOOR AIR INCREASED TO 361 CFM. THE UNIT IS MAXIMIZED BUT ONLY PERFORMING TO 88% OF DESIGN. Date: 4/1/2014 Powered by FaciliBuild! Page 3 of 15 www.facilibuild.com National TAB NAiIONAI•Tp6 Project: Chipotle - Southcenter Mall #2270 DUCTWORK SITE EVAL Assigned Organization: National TAB Status: Submitted Asset: HVAC DUCTWORK CHECKLIST - Ductwork and diffusers are installed per Yes design - Balance dampers installed and functional Yes - Balance dampers are accessible Yes - Ductwork is properly covered with insulation, Yes & Insulation is secured - Tops of diffusers are properly insulated Yes - Installed diffusers match design Yes Notes/Comments: Date: 4/1/2014 Powered by FaciliBuild! Page 4 of 15 www.facilibuild.com National TAB NAiIONAI•TAB EXHAUST FAN SITE EVAL Project: Chipotle - Southcenter Mall #2270 Assigned Organization: National TAB Status: Submitted EXHAUST FAN - Verify units marked for easy identification Yes - Unit sealed and properly seated to roof curb Yes No unusual vibration or noise Yes - Belts properly tensioned and free of damage Yes - Pulleys properly aligned Yes - Blower wheel moves freely by hand Yes - Unit is providing required airflow Yes - Verify on/off disconnect works Yes - Verify voltage input is correct Yes - Fan rotation is correct (compare to arrow Yes Notes/Comments: Asset: Date: 4/1/2014 Powered by Facilieuild! Page 5 of 15 www.facilibuild.com Nanoity6 National TAB Project: Chipotle - Southcenter Mall #2270 GV-1 CHECKLIST Assigned Organization: National TAB Status: Submitted Asset: Device is secured to the curb. Yes Backdraft damper is installed properly. Yes Backdraft damper can fully open without hitting Yes exhaust fan. Backdraft damper can freely move and is not Yes getting stuck. Notes/Comments: Date: 4/1/2014 Powered by FaciliBuild! Page 6 of 15 www.facilibuild.com National TAB NAflOf1Al • T11B Project: Chipotle - Southcenter Mall #2270 RTU SITE EVAL Assigned Organization: National TAB Status: Submitted Asset: RTU CHECKLIST - Units are labeled and installed at proper Yes locations - Units size matches its design (nameplate) Yes - Clean filters are installed at DX coil Yes - Belts are tight and in good working order Yes - Pulleys are properly aligned Yes - Motors rotating correctly Yes - Units sealed and properly seated to roof curb Yes - Evaporator coils clean and free of debris Yes - Gas piping installed Yes - Gas valves turned in the on position Yes - Condensate lines and P-traps installed Yes correctly - No noticeable vibration or noise exist correct? Yes - Outside air dampers installed and functioning Yes - Condensor coil clean and free of damage Yes - Verify voltage input correct Yes - Compressors operating in correct rotation Yes - Heating mode tested satisfactorily Yes - Cooling mode tested satisfactorily Yes - Any additional comments/notes: Notes/Comments: DIRECT DRIVE UNIT. ALL BELT AND PULLEY INFO IS N/A. UNIT IS SUSPENDED. Powered by FaciliBuild! Date: 4/1/2014 Page 7 of 15 www.facilibuild.com NanoJAVe SMOKE CONTAINMENT AND BLDG PRESSURE TESTS National TAB Project: Chipotle - Southcenter Mall #2270 Assigned Organization: National TAB Status: Completed Asset: HOOD CAPTURE TEST LIST EQUIPMENT TURNED ON FOR N/A, GAS RUN TO EQUIPMENT BUT HAS NOT UNDERGONE TESTING STARTUP. LIST SMOKE CANDLE TYPE USED SMOKEY SMOKE TEST CAPTURE - PERIMETER OF PASS HOOD SMOKE TEST CAPTURE - TOP OF COOKING PASS SURFACE WITNESS DATE TEST WAS COMPLETED 4/1/2014 TAB TECH NAME / FIRM PHIL MCCARROLL / NATIONAL TAB SITE SUPR NAME / FIRM • GABE HARVISON / WESTERN CONSTRUCTION OWNER REPRESENTATIVE NAME / FIRM (IF NOT PRESENT APPLICABLE) CODE OFFICIAL NAME / FIRM (IF NOT PRESENT APPLICABLE) BUILDING PRESSUR AT FRONT & BACK STORE OPEN TO FOOD COURT DOORS (ALL SYSTEMS ON) Notes/Comments: Date: 4/1/2014 Powered by FaciliBuild! Page 8 of 15 www.facilibuild.com NanoCAZ,B Asset: AH1 National TAB Project: Chipotle - Southcenter Mall #2270 System/Unit: AHU/RTU AREA: KITCHEN Unit Data Design Actual MFG TRANE TRANE Model Num TAM7B0 TAM7B0 Serial Num 14114H8CAV Type AHU AHU Configuration HORIZONTAL HORIZONTAL Num OA Filters 1 1 OA Filter Size 1 12" DIA Num OA Filters 2 N/A OA Filter Size 2 N/A Num Final Filter 1 1 Final Filter Size 1 20X22X1 Num Final Filter 2 N/A Final Filter Size 2 N/A Motor Data Design Actual Motor MFG N/A Frame N/A Horsepower 1.0 Motor Rpm N/A Phase 3 1 Rated Voltage 208 200-230 Rated Amperage 5.5 Service Factor N/A Efficiency N/A Power Factor N/A Drive Data Design Actual Motor Sheave Size DD Motor Bore Size DD Motor Sheave SetPt DD Fan Sheave Size DD Fan Sheave Bore DD Belt CL Distance DD Num of Belts DD Belt Size DD Belt Alignment DD Notes: Test Data Design Actual SF CFM 1900 1595 SF RPM DD RA CFM 1400 1234 OA CFM 500 361 RL Voltage 205 RL Amperage 2.1 SF Rotation CW VFD Max SetPt N/A RA Damper Position PLEASE SEE NOTES: 99% CLOSED Min OA Damper Position 100% OPEN Min OA Damper Type MOTORIZED DAMPER Performance Data Design Actual Fan Suction SP -0.674 Fan Discharge SP 0.439 Total ESP 1.0 0.618 Fan Total SP 1.11 General Design Actual Fan Rotation Correct YES (CW FROM TOP DOWN PERSPECTIVE) Unit Filters Clean YES Date: 4/1/2014 Powered by FaciliBuild! Page 9 of 15 www.facilibuild.com NATIO e National TAB Project: Chipotle - Southcenter Mali #2270 System/Unit: AHU/RTU Asset: AREA: OUTSIDE AIR FED BY CIRCULAR DUCT WITH CAPTIVE AIRE ROOF CAP. UNABLE TO READ MOTOR LABEL. MOTOR INFO TAKEN FROM UNIT LABEL. PRE-DAMPERING CFM: 1675 UNIT MAXIMIZED BUT ONLY PERFORMING TO 88% OF DESIGN. UNABLE TO ATTAIN 500 CFM O/A. OPENED O/A DAMPER 100% AND ESSENTIALLY CLOSED R/A DAMPERS. MAXIMUM O/A ATTAINED WAS 361 CFM. THIS IS APPROXIMATELY 22% OF CURRENT UNIT OUTPUT. Diffuser Supply (GRD) AH1 Asset Area Served Type Size DESIGN CFM AK CFM(1) CFM(2) FINAL CFM %to design AHU1-SGRD1 SERVE LINE PERF 11X11 250 227 217 86.8 AHU1-SGRD2 SERVE LINE PERF 11X11 250 173 200 80.0 AHU1-SGRD3 SERVE LINE PERF 11X11 250 199 205 82.0 AHU1-SGRD4 SERVE LINE PERF 11X11 250 218 218 87.2 AHU1-SGRD5 SERVE LINE PERF 24X24 300 246 246 82.0 AHU1-SGRD6 KITCHEN PERF 24X24 300 183 240 80.0 AHU1-SGRD7 OFFICE PERF 11X11 100 210 83 83.0 AHU1-SGRD8 KITCHEN PERF 24X24 200 218 186 93.0 Asset Area Served Notes Date: 4/1/2014 Powered by FaciliBuild! Page 10 of 15 www.facilibuild.com National TAB NAilOAAL•TAB Asset: EF1 Project: Chipotle - Southcenter Mall #2270 System/Unit: FAN - Exhaust AREA: HOOD 1 Unit Data Design Actual MFG CAPTIVE-AIRE CAPTIVE-AIRE Model Num DU85HFA DU85HFA Serial Num 1882165 Type CENTRIFIGUL UPBLAST Configuration UPBLAST VERTICAL Motor Data Design Actual Motor MFG HSSA Frame 48Y Horsepower 3/4 3/4 Motor Rpm 1625 Phase 1 1 Voltage (rated) 277 115/230 Amperage (rated) 11.3/6.0 Service Factor 1.0 Notes: Test Data Design Actual CFM 1800 1871 Fan RPM DD Fan Rotation CCW Motor RPM DD System SetPt WIRED HIGH, SET MED RL Voltage 118 RL Amperage 10.3 Total ESP 1.2 0.467 Fan Inlet SP -0.467 Fan Discharge SP ATM Date: 4/1/2014 Powered by Facilieuild! Page 11 of 15 www.facilibuild.com aano�ai�e Asset: EF2 National TAB Project: Chipotle - Southcenter Mall #2270 System/Unit: FAN - Exhaust AREA: HOOD 2 Unit Data Design Actual MFG CAPTIVE-AIRE CAPTIVE-AIRE Model Num DU3OHFA DU3OHFA Serial Num 1882165 Type CENTRIFUGAL UPBLAST Configuration UPBLAST VERTICAL Motor Data Design Actual Motor MFG HSSA Frame 48Y Horsepower 0.25 1/4 Motor Rpm 1625 Phase 1 1 Voltage (rated) 120 115/230 Amperage (rated) 4.9/1.9 Service Factor 1.0 Notes: Test Data Design Actual CFM 475 477 Fan RPM DD Fan Rotation CCW Motor RPM DD System SetPt WIRED HIGH, SET LOW RL Voltage 119 RL Amperage 3.7 Total ESP 0.3 0.164 Fan Inlet SP -0.164 Fan Discharge SP ATM Date: 4/1/2014 Powered by FaciliBuild! Page 12 of 15 www.facilibuild.com NAflONAI•TAB 4, Asset: SF1 National TAB Project: Chipotle - Southcenter Mali #2270 System/Unit: FAN - Supply AREA: HOOD 1 SUPPLY Unit Data Design Actual MFG CAPTIVE-AIRE CAPTIVE-AIRE Model Num D76 D76 Serial Num 1882165 Type DIRECT FIRED DIRECT -FIRED Configuration DOWN DISCHARGE DOWN DISCHARGE Motor Data Design Actual Motor MFG WEG Frame D56 Horsepower 1 1 /2 1.5 Motor Rpm 1720 Phase 3 3 Voltage (rated) 460 208-230/460 Amperage (rated) 4.70-4.20/ Service Factor 1.15 Efficiency 77 Power Factor 0.81 Drive Data Design Actual Motor Sheave Size 1 VP50 Motor Bore Size 5/8 Fan Sheave Size AK39 Fan Sheave Bore 3/4 Belt CL Distance 10" Num of Belts 1 Belt Size AX31 Belt Alignment Verified YES Gas Heat Design Actual Heater Operates (y/n) YES Flame Status (pass/fail) PASS Inlet Air Temp SetPt 55 55 Discharge Air Temp SetPt 60 60 Notes: Test Data Design Actual CFM 1175 1117 SF RPM 2109 SF Rotation CW Motor RPM 1753 RL Voltage 477,477,477 RL Amperage 1.9,1.9,1.9 Total ESP 0.8 N/A Fan Discharge SP N/A General Design Actual Fan Rotation Correct YES Date: 4/1/2014 Powered by FaciliBuild! Page 13 of 15 www.facilibuild.com National TAB NAflOkA• TAB Project: Chipotle - Southcenter Mall #2270 System/Unit: Kitchen Hood Type I Asset: HD(TYPE 1)-1 AREA: MAIN COOKLINE Unit Data Design Actual MFG CAPTIVE-AIRE CAPTIVE-AIRE Model Num 5424 ND-PSP 5424 ND-PSP Job / Serial Num 1882165 Type TYPE I CANOPY TYPE I CANOPY Hood length 96" 96" Hood Width 54" 54" Supply Plenum Type PSP PSP Supply Plenum Width 12" 12" Supply Plenum Length 111" 111" Test Data Exhaust Design Actual Filter Type CAPTRATE SOLO CAPTRATE SOLO Filter Size 1 16X16 16X16 Filter Size 2 16X20 16X20 Filter Qty 1 1 1 Filter Qty 2 4 4 Filter AK factor size 1 1.62 1.62 Filters AK factor size 2 2.08 2.08 Filter Total AK Area 9.94 9.94 Filter High FPM(corr) 192 Filter Low FPM (corr) 184 Filter Ave FPM(corr) 188 CFM 1800 1871 Test Data Supply Design Actual Total AK Area 9.25 9.25 Num of Readings 9 High FPM(corr) 150 Low FPM(corr) 123 Ave FPM(corr) 120.74 CFM 1175 1116 Performance Data Design Actual Exh-Supply Net CFM 625 754 Smoke Generation Type SMOKEY Cooking Equip Heat On NONE, GAS NOT TURNED ON Hood Capture % 100 General Design Actual Third Party Witness Third Party Company WESTERN CONSTRUCTIO N Tech Witness PHIL MCCARROLL Tech Company NATIONAL TAB Code Official Witness NOT PRESENT Jurisdiction NOT PRESENT Notes: PSP CREATES CAPTURE ISSUES IF MOTOR INCREASED AT ALL. Date: 4/1/2014 Powered by FaciliBuild! Page 14 of 15 www.facilibuild.com NAiiOflAL-TAB 40/ Asset: HD(TYPE 2)-1 National TAB Project: Chipotle - Southcenter Mall #2270 System/Unit: Kitchen Hood Type 1I AREA: TYPE II HOOD Unit Data Design Actual MFG CAPTIVE-AIRE CAPTIVE-AIRE Model Num 5424 VHB-ND 5424 VHB-ND Serial Num 1882165 Type TYPE II CANOPY TYPE II CANOPY Hood length 57" 57" Hood Width 54" 54" Notes: Test Data Design Actual Exhaust CFM 475 477 Date: 4/1/2014 Powered by FaciliBuild! Page 15 of 15 www.facilibuild.com Erickson Refrigeration LLC Page 1 of 2 Washington State Department of Labor & Industries Erickson Refrigeration LLC Owner or tradesperson EDWARDS, GREGORY J Principals EDWARDS, GREGORY J Doing business as Erickson Refrigeration LLC WA UBI No. 602 592 091 PO Box 1426 MOSES LAKE, WA98837 253-333-7294 GRANT County Business type Limited Liability Company Governing persons GREGORY JOHN EDWARDS License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties Heating/Vent/Air-Conditioning and Refrig (HVAC/R) License no. ERICKRL922QE Effective — expiration 11/05/2008 — 03/21/2016 Bond American States Insurance Co Bond account no. 32S206749 Received by L&I 05/07/2012 Insurance Mid -Century Ins Co Policy no. 605041166 Received by L&I 09/09/2013 Active. Meets current requirements. $6,000.00 Effective date 04/20/2012 $2,000,000.00 Effective date 09/16/2011 Expiration date 09/13/2014 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602592091 &LIC=ERICKRL922QE&SAW= 03/26/2014