Loading...
HomeMy WebLinkAboutPermit M14-0080 - FIVE GUYS BURGERS AND FRIES - HVAC, GREASE DUCTS AND FANSFIVE GUYS BURGERS & FRIES 17100 SOUTHCENTER PKWY STE 112 M14-0080 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 7888920020 Permit Number: M14-0080 17100 SOUTHCENTER PKWY Unit112 Issue Date: 8/7/2014 Permit Expires On: 2/3/2015 Project Name: FIVE GUYS BURGERS AND FRIES Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: WIG PROPERTIES LLC-SS 4811 134TH PL SE , BELLEVUE, OR, 98006 PAUL REED 1006 SE GRAND AVE, STE 300 , PORTLAND, OR, 97214 METRO AIR INC Address: 11021 128 PL NE , KIRKLAND, WA, 98033 Phone: (503) 546-1600 Phone: (425) 889-8224 License No: METROAI995RC Expiration Date: 12/3/2015 Lender: Name: Address: Ill DESCRIPTION OF WORK: MECHANICAL WORK TO INCLUDE HVAC, GREASE DUCTS, AND EXHAUST FANS Valuation of Work: $0.00 Type of Work: Fuel type: Fees Collected: $585.58 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: Permit Center Authorized Signature: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: ‘,3:10 2012 2012 2012 Date: a-- 7 -t _ t I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permed agree to the conditions attached to this permit. Signature: Print Name: Sty. fwLo J Date: 5— (— Zo This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 11: Type 1 Hoods, the required grease duct leakage test and (light test shall be performed by a special inspection and testing agency in accordance with I.M.C. Chapter 5. 12: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 13: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 30: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 15: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire -extinguishing system installed in accordance with this code. (IFC 610.2, IFC 904.2.1 and IFC 904.11) Automatic fire -extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) 18: Type I hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. (IMC 507.2.1.1) 17: All new automatic fire -extinguishing systems and all modifications to existing automatic fire -extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 20: Local U.L. central station supervision is required. (City Ordinance #2328) 16: Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial - type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 14: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 23: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2328) 24: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 25: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2328) 21: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2328) 26: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2328) 22: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 27: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 19: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 28: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 29: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWI Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. j'J I " 0( 1U Project No. Date Application Accepted: LY'\k� Date Application Expires: V9 V (1 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 7888920020 Site Address: 17250 Southcenter Pkwy Suite Number: 112 Floor: 1 Tenant Name: Five Guys Burgers and Fries PROPERTY OWNER Name: WIG Properties Address: 4811 134th P1 SE City: Bellevue State: WA Zip: 98006 CONTACT PERSON — person receiving all project communication Name: Paul Reed Address: 1006 SE Grand Ave, Suite 300 City: Portland State: OR Zip: 97214 Phone: (503) 546-1600 Fax: (503) 546-1601 Email: paulr@baysingerpartners.com New Tenant: © Yes ❑ .. No MECHANICAL CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ 30,000 Describe the scope of work in detail: HVAC, grease ducts and exhaust fans Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement EI Fuel Type: Electric ❑ Gas Other: H: Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh //.2_ Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <1 OOk btu Furnace > l 00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent 1 Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system 1 Hood and duct 1 Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser 26 Thermostat Wood/gas stove Emergency generator Other mechanical equipment 1 Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 03/21/2014 Print Name: Paul Reed Day Telephone: (503) 546-1600 Mailing Address: 1006 SE Grand Ave, Suite 300 Portland OR 97214 City State Zip H: Applications \Forms -Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-1 I .docx Revised: August 201 I bh Page 2 of 2 DESCRIPTIONS PermitTRAK Cash Register Receipt City of Tukwila ACCOUNT QUANTITY ( PAID 4729 M 14-0080 Address: 17100 SOUTHCENTER PKWY Unit112 n 7888920020 472.97 MECHANICAL $450.45 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $417.95 TECHNOLOGY FEE $22.52 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2803 R000.322.900.04.00 0.00 $22.52 $472.97 Date Paid: Thursday, August 07, 2014 Paid By: ASH HANLON METRO AIR INC Pay Method: CREDIT CARD 087369 Printed: Thursday, August 07, 2014 10:56 AM 1 of 1 !SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK M14-0080 Address: 17250 SOUTHCENTER PKWY 112 Apn: 7888920020 PAID $112.61 $112.61 $112.61 $112.61 $112.61 MECHANICAL PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R1720 R000.322.102.00.00 Date Paid: Monday, April 07, 2014 Paid By: TUKWILA BURGERS INC Pay Method: CHECK 1004 Printed: Monday, April 07, 2014 10:27 AM 1 of 1 SYSTEMS V) INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 oog 0 Project: r— Type of Inspection: Address: 1-7 100 So.)* I "\r'Ph I_ IJ,, Date Called: `i -- (1 ` l 4 Special Instructions: V\rt a d 00 1 Date Wanted: _ a.m1 gip.. Requester: !\ Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: tu (0 co &No k e SIn rCi 1\),-x . )+ 1 . Q_nJ/(%) // %,.\ 1 \.'XAA ( PS 1 ` ,),PI;r.Je C k" A\ A C`t"\-) ��e' ir iNIA IrnSpectbr: Date: `1- REINSPECTION FEE REQUIRED. Prio ; to next inspection, fee must be part 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD IR / Retain a copy with permit "t r-f PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: ID C�,i,16 Type of Inspection: ► LJv' 1 1b(r- Address: / / I, t) �} ril Date Called: J J 6 Special Instructions: ) 4\1",.)<A) (41 k) - al dr Date Wanted: Olog a.m. p.m. Requester: �.,22 Y I 11 / ,, Phone No: Z-C- ,2-lai7 (#913tif Approved per applicable codes. Corrections required prior to approval. COMMENTS: f) K.. -. Q x i J D (U • ) V , \-17 , - t Sr 1T'' .) y 6kCiT 0/!-9 APP. . i ?) 1, G \AA )K?. Sk -i-),) LA) ri r_ t Inspector: Date:t 1 4- REINSPECTIONTEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit,. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 1 TL� ddgj PERMIT N0. Project: , /—,�� GGA.,s Type of Inspection: -Pi // ,fie • t ,,, Address: / /7/ -CCo v/frr.,1 &J Date Called: „ i.e t/r i Special Instructions: Date Wanted: ... .',_. / y (a.m.. P.m. Requester: Phone No: `approved per applicable codes. El Corrections required prior to approval. COMMENTS: A hispect r: -- Date;, . C, i J La 7 FIt REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. hispect r: -- Date;, . C, i J La 7 FIt REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Information lb Build On Engineering • Consulting • Testing September 18, 2014 FINAL LETTER City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, Washington 98188 RE: Permit No. M14-0080 We have completed the requested special inspections on the subject project. All work requiring special inspection was, to the best of this agency's knowledge, inspected and reported as specified on permit documents. Project Name: Five Guys Burger and Fries Project Address 17100 Southcenter Parkway Permit No. M14-0080 We have completed the requested special inspections on the subject project. All work requiring special inspection was, to the best of this agency's knowledge, inspected and reported as specified on permit documents. • Grease Duct Light Inspection If there are any questions regarding this change please contact PSI at (425) 248-2400. Sincerely, Daniel Kuhn Branch Manager CITY (�F7UEO KWfa.A NOV 10 2014 PERMIT CENTER PROFESSIONAL SERVICE INDUSTRIES, INC. Special Inspection Daily Field Report CLIENT: PROJECT: /22 LrS 1 l Professional Service Industries, Inc. ❑ Professional Service Industries, Inc. 24113 56th Avenue W. 10025 South Tacoma Way, #H1 Mountlake Terrace, WA 98043 Tacoma, WA 98499 Phone: (425)248-2400 Fax (425) 248-2401 Fax: (253) 589-2136 rv'l 1- r)aCr WORK ORDER NO.: 0 7j2, DATE: Phone: (253) 589-1804 r-- )/sL. General Contractor: Permits: Weather: 7— Reinforced Concrete ❑ Structural Masonry ❑ High Strength Bolting ❑ fireproofing Reinforcing Steel ❑ Soils ❑ Welding ❑ Other El New Inspection ❑ Re -Inspection Standby Time: Special Inspection Continuous e! Periodic Locatlon(s)/Item(s): Referenced Details/Drawings: Remarks: oAJ s/ 1W ' /"--/ i V,J ' �- m f r� Tt,—'c,C! / 4- seI u4 , +k'm (? ev TT 1-4r1C ,r/krt r Z.. 46-1G11 /').r / DC D (/G ?` /J) k'`bi-o p note,z0,JT44.. s .l AC? Y /i//u )t; T<,) f�.t9/. )..SAS% 0r / 6725., Gfr(40 C4PA'60^) .ST 4 o r D -- f To the best of PSI's knowledge, the work inspected to the approved construction documents are: 0 Conforming ❑ Non -Conforming Inspector: / ,/ c; `L / /-\> Jobsite Representative: Inspector Cert No.: 'f ( /`= ,C These test results apply only to the specific locations and materials noted and may not represent any other locations or elevations. This report may not be reproduced, except in full, without written permission by Professional Service Industries, Inc. ICC SP, Rev. 01/26110 • PROFESSIONAL SERVICE INDUSTRIES, INC. Special Inspection Daily Field Report 0 Professional Service Industries, Inc 24113 56th Avenue W. Mountlake Terrace, WA 98043 Phone: (425) 248-2400 Fax: (425) 248-2401 0 Professional Service Industries, Inc. 10025 South Tacoma Way, #H1 Tacoma, WA 98499 Phone: (253) 589-1804 Fax: (253) 589-2136 CLIENT: WORK ORDER NO.: 0 2/ // / 3 ,3 PROJECT: ‘5.-- t5t, 4 r? �(,/x?e.:—, 's,,..„ DATE: G1 .-., ., - /9./SL.. /7/o0 LSdr,/Tti'' General Contractor: l N% ' ,9( iY Permits: /22 /4 --c7E7X0 Weather: dv'`) Fa Type of: Inspection Performer ❑ Reinforced Concrete ❑ Structural Masonry ❑ High Strength Bolting ❑ Fireproofing ❑ Reinforcing Steel ❑ Soils ❑ Welding ❑ Other ❑ New Inspection ❑ Re -Inspection Standby Time: 4?Special Inspection ❑ Continuous Field Observations & Comments "Periodic Location(s)/Item(s): ;fro.4GdE' E �rJ( i<<'ez3v--)7-7-0.21-7 Referenced Details/Drawings: Remarks: l'•,/ % �i /-�s� e V b r> �b,a /' S 7-etch," (9 7- .) r_ir-2 ."9A- "4`7 Gv,7 s (-/ NV / T A ? A /r /.,/ i //RI)C.o►rW',�.Y.-IJ z'..0 To the best of PSI's knowledge, the work inspected to the approved construction documents are: ,,'%Conforming ❑ Non -Conforming Inspector: Jobsite Representative: Inspector Cert No.: These test results apply only to the specific locations and materials noted and may not represent any other locations or elevations. This report may not be reproduced, except in full, without written permission by Professional Service Industries, Inc. ICC SP, Rev. 01/26/10 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0080 DATE: 04/04/2014 PROJECT NAME: FIVE GUYS BURGERS & FRIES SITE ADDRESS: 17250 SOUTHCENTER PY, STE 112 X Original Plan Submittal Response to Correction Letter # Revision #_ Revision # before Permit Issued after Permit Issued DEPARTMENTS: 'PET- Pco Building Division Public Works Fire Prevention Structural Vic, LI-124-H ■ Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 04/03/14 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) DUE DATE: 05/01/14 Approved with Conditions W**— Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 METRO AIR INC Page 1 of 3 Washington State Department of Labor & Industries METRO AIR INC Owner or tradesperson SCHEFFLER, MICHAEL ALLEN Principals SCHEFFLER, MICHAEL ALLEN, PRESIDENT HANLON, ASH T, VICE PRESIDENT Doing business as METRO AIR INC WA UBI No. 602 156 865 11021 128TH PL NE KIRKLAND, WA98033 425-889-8224 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties Heating/Vent/Air-Conditioning and Refrig (HVAC/R) License no. METROAI995RC Effective — expiration 12/03/2001-12/03/2015 Bond CBIC Bond account no. SE0682 Received by L&I 12/03/2001 Insurance Ohio Cas Ins Co Policy no. BKO(12)53356859 Received by L&I 10/16/2013 $6,000.00 Effective date 11/15/2001 Expiration date Until Canceled $1,000,000.00 Effective date 11/15/2011 Expiration date 11/15/2014 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602156865&LIC=METROAI995RC&SAW= 08/07/2014 LEGEND • BALL VALVE--- LIQUIDS UP TO 2" BUTTERFLY VALVE--- LIQUIDS ABOVE 2" - GATE VALVE--- STEAM, UNDERGROUND, (OS&Y VALVES) GLOBE VALVE--- PRESSURE REDUCING STATION, HOSE BIBS GAS PRESSURE REDUCING VALVE ANGLED VALVE, SEE ABOVE - PRESSURE/TEMP RELIEF VALVE ICI CONCENTRIC REDUCER ECENTRIC REDUCER, STEAM LINES N CHECK VALVE DOUBLE CHECK ASSEMBLY, LEFT TO RIGHT FLOW STRAINER (STEAM LINES) STRAINER W/ BLOW OFF VALVE, (STEAM LINES) BALANCING VALVE, SQUARE HEAD COCK CIRCUIT SETTER KITCHEN EQUIPMENT CALL OUT PLUMBING CALCULATIONS FIXTURE TYPE LAVATORY (SINGLE) MOP BASIN RECEPTOR (INDIRECT WASTE) SINK GENERAL (3" TRAP) WATER CLOSET (1.6 GPF FLUSHOMETER TANK -GENERAL) DOMESTIC WATER SERVICE NUMBER WATER OF FIXTURES FIXTURE UNITS 4 9 2 TOTAL 18 GPM TOTAL TOTAL CW TOTAL HW WSFU FIXTURE FIXTURE UNITS UNITS 3 6 2.5 5 18 34 3 2.25 4.5 5 14.75 32 3 2.25 4.5 0 9.75 8 SANITARY WASTE SERVICE DRAINAGE TOTAL FIXTURE DFU UNITS 3 1 4 4 3 9 12 8 36 WASTE SIZE 4" Grease Interceptor Calculations FIXTURE TYPE MOP BASIN RECEPTOR (INDIRECT WASTE) SINK GENERAL (3" TRAP) HYDROMECHANICAL INTERCEPTOR NUMBER DRAINAGE TOTAL OF FIXTURES FIXTURE DFU UNITS 9 2 3 1 6 3 9 12 TOTAL 24 75 GPM KITCHEN. Ec U I FMENT SCHEDULE NO. DESGRI PTI ON WASTE CAS REMARKS INAThR 'INDIRECT_ HOT COW DIRECT 14#1 SIZE IIB TEA DISPENSER 1/2" 3/4" FILTERED GOLD WATER I2A 1/2" SODA DISPENSER (8 VALVE) SODA DISPENSER (8 VALVE) 14 ICE MACHINE (8 VALVE) 1/2" 3/4" _ FILTERED COLD WATER 20 GAS GRIDDLE q0 208 GAS GRIDDLE 150 22 • 380 GAS FRYER . 27 HAND SINK 1/2" 1/2" I I/2'' 21A 3 COMPARTMENT SINK 1/2" 1/2" 3®I 1/2" 21B 4 COMPARTMENT SINK 1/2" 1/2" 4®1 I/2" 210 MOP SINK (INC WET MOP HANGER) 1/2" 1/2" 3" 30 WALK-IN COOLER 1/2" 33 CO2 _ LOCATED AT BUILDING TRASH 34A BAG-N-BOX 1/2" FILTERED GOLD WATER 36A 3/4" WATER FILTER 31G 3/4" 5/4" KM EF-6OT-IagE-3N WA i Li HEATER NOTES: 1. ALL INDIRECT WASTE CONNECTIONS SHALL BE VERIFIED IN THE FIELD WITH THE ACTUAL EQUIPMENT OUTLET SIZE. ALL INDIRECT WASTE TO BE EXTENDED TO FLOOR DRAINS AS INDICATED. 2. FURNISH AND INSTALL VACUUM BREAKERS ON THE BEVERAGE DISPENSING UNITS, MOP SINKS, ETC. 3. CONNECTIONS TO ALL EQUIPMENT SHALL HAVE UNIONS AND SERVICE VALVES. TYPICAL FOR DOMESTIC WATER AND GAS PIPING CONNECTIONS. 4. GAS CONNECTIONS SHALL BE COMPLETE WITH FLEXIBLE UL/AGA APPROVED HOSE AND MANUAL SHUT-OFF VALVES. 5. ALL GAS FIRED KITCHEN EQUIPMENT SHALL BE PROVIDED WITH UL/AGA LABELED GAS PRESSURE REGULATORS. PROVIDE VENT PIPING AS REQUIRED. 6. ALL EQUIPMENT ROUGH -INS SHALL BE COORDINATED WITH APPROVED EQUIPMENT SHOP DRAWINGS. 7. ALL KITCHEN EQUIPMENT PURCHASED AND INSTALLED BY OTHERS. 8. THIS PROJECT SHALL COMPLY WITH THE 2012 UPC, IMC, IFGC, AND WASHINGTON STATE ENERGY CODE, INCLUDING THE WASHINGTON STATE AMENDMENTS. FLUM SINS CONNECTION SCHEDULE MARK FIXTURE W V CW HW REMARKS FD-1 FLOOR DRAIN 3" 2" ZURN 415B FS-1 FLOOR. SINK 4" 2" • • ZURN 1926 TD-1 TRENCH DRAIN 4"* 2" SEE ARCHITECTURAL LV-1 LAVATORY 1-1/2" 1-1/2" 1/2'' 1/2" WALL MOUNT WC-1 WATER CLOSET 3" 2" 1/2" FLOOR MOUNT, FLUSH TANK * - TRENCH DRAIN BY ARCHITECT, COORDINATE .WITH ARCHITECT FOR CONNECTION SIZE 1/2" - id 3/4" L. �T WATER FILTER BACKFLOW PREVENTER (TYPICAL) 1/2" 1/2" FILTERED WATER DIAGRAM NO SCALE 1-1 1/2" 1/2" REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan r*viewless. � FILE PY SO Plan review awrovali—"Danis and oilisti. of oarlstrtwICtn 630111Will does not prize $i ., Sion, of an +:,., r <oiXle or witsacte. R= ►; !t leppoved SEPARATE PERMIT REQUIRED FOR CI Mebhanicat sect icat Ulnas Plpki City of Tukwila BUfLDING DIVISION l' OWING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED APR i 7 2014 114 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 0 4 2014 PERMIT CENTER FIVE auYs® BURGERS and FRIES Consulting Engineers 2007 S.E. Ash St. Portland, OR 97214 PHN: 503) 234-0548 FAX: (503) 234-0677 INC. wwm.MFIA—ENG. coM CONTACT: JAMES TORMEY NOTES SUBMITTALS ITEM DESGRIPTION DATE BID AND PLAN REVIEW SET ISSUE 03.18.14 FIVE GUYS BURGERS & FRIES TUKWILA, WA LUMB LEGEND, SCHEDULES, DETAIL MANAGER: JLT FLOOR: onto PROJ. #: FILE: 818q—MI DRAFTSMAN: BKG (E ) W i ca i Mai WASHROOM 104 FFMAI FI WASHROOM] 105 (E) GW W 4� 1.03 > 4'GW V Y m, 110 11111 NAM/ Far -11 TD-1 GW�I 2" V FS-1. V i TD-1 2" V i GW C TD-1 FS-1 3" VTR • 1D11 11 RIN REUEL 000 oc ooc moo J / • 4" GW T 102 000010 00 000 A ©--"-J ❑ 01.1 • ❑ G) TD-1 g C��//-7 -7—Q7 / / / / / /// / / // "..fib / / / / / / / / / _/ _/ -, HAI I WAY] 106 P 2" V ii JI J L-"� ►`4 CO 3" GW GWGWGW MINIM ',NM a 'MINIM!! ANY ...... NI., WASTE AND VENT PLAN 2 SCALE: 1/4" = 1'-0" 1.MQQQQ1 IM. 4 it / / FS-1 IDININGI 101 WASTE AND VENT RISER DIAGRAM NO SCALE FS-1 GENERAL NOTES 1. VERIFY DEPTH OF EXISTING WASTE AND GREASE WASTE LINES BEFORE BEGINNING INSTALLATION. SHEET NOTES O CONNECT TO EXISTING WASTE AND GREASE WASTE LINES. FIELD VERIFY LOCATION AND DEPTH. RECEIVED CITY OF TUKWILA APR 0 4 2014 PERMIT CENTER BAYS1NGER PAR-NERS FIVE GUYS® f3URGD S and FRIES MConsulting Engineers FI2007 S.E. Ash St. Portland, OR 97214 PHN: (503) 234-0548 FAX: (03) 234-0677 INC. �PIPIP.MFLk—ENG.COM CONTACT: JIM TORMEY NOTES SU 3M I TTALS ITEM DESCRIPTION DATE BID AND PLAN REVIEW SET ISSUE 03.18.14 FIVE GUYS BURGERS & FRIES TUKWILA, WA 1NASTE AND VENT PLAN SCALE: 1/4" = 1'-0" PROD. #: MANAGER: JLT DRAFTSMAN: BKG FLOOR: V -2 FILE: 87801—M2 II=CT: OF 1 1/4" CW 1/2" HW () TO 3/4" 1 1 / WC-1 re, FD -1 c 0 _a LV-1\ (0) L.. 3/4" FILTERED \ WATER FD-1 wc- FD -4 PRFPI ROOMI 103 CW HW FS-1 7 TD-1. TD -1 I Tr) 56 11111DO EH our llom RH MK DOE[FLEJIE c D FS-1 r=== 000 =0=3 =11=.3110 =0= =.10 =30= ====3 —=3.= `VI w PVT.' LI- --F L 7\- -11 jj jj 0 KITCHNI 102 VILJ E / / / / / / / / / // / / / // / / / / / I / / / / / / / / / / / / / / / -(oi TT / / 41 •• • • A • d.v..?,044.4,46.+ae.,4440.46,4,46.60..46.1. ,N.4.4•47ar HAI 1 WAY' 106 IL_ 1•MMI•411-;:51•1•.-.1•514.- -.1•21410-144-4r-X-A0181•1•-•41 3/4" FILTERED WATER WATER PLAN 3 SCALE: 1 /4" = 1 '-0" DININGI 101 GENERAL NOTES 1. VERIFY LOCATION OF EXISTING WATER LINE CONNECTION BEFORE BEGINNING INSTALLATION. SHEET NOTES: O CONNECT TO EXISTING CAPPED 2" CW IN CEILING. 0 DOMESTIC COLD WATER PIPING ABOVE CEILING/MOUNTED FROM STRUCTURE. 0 DOMESTIC HOT WATER PIPING ABOVE CEILING/MOUNTED FROM STRUCTURE. O FILTERED COLD WATER PIPING ROUTED LOW IN WALL/CHASE. SEPARATE PERMITAND APPROVAL REQUIRED RECEIVED CITY OF TUKWILA APR 0 4 2014 FIVE GUYS® BURGERS and FRIES Consulting Engineers 2007 S.E. Ash St. Portland, OR 97214 PHN: (503) 234-0548 FAX: (503) 234-0677 INC. WWW.MFIA—ENG.COM CONTACT: JIM TORMEY NOTES SUBMITTALS ITEM DESCRIPTION DATE BID AND PLAN REVIEW SET ISSUE 03.15.14 FIVE GUYS BURGERS & FRIES TUKINILA, INA WATER PLAN SCALE: 1/4" = I '-0" PROJ. #: MANAGER: JLT DRAFTSMAN: BKG FLOOR: I PERMIT CENTER FILE: 5-151_M3 I ILCT: OF MECHANICAL LEGEND 1 ► OR m 0 • (E) ( AC-4 0 u SUPPLY AIR DIFFUSER RETURN AIR GRILLE EXHAUST AIR GRILLE PERFORATED RETURN AIR PANEL DIRECTIONAL AIR FLOW MANUAL VOLUME DAMPER SUPPLY OR OUTSIDE AIR DUCT UP & DOWN RETURN AIR DUCT UP & DOWN EXHAUST AIR DUCT UP & DOWN SUPPLY OR OUTSIDE AIR DUCT UP & DOWN RETURN AIR DUCT UP & DOWN EXHAUST AIR DUCT UP & DOWN VAV TERMINAL UNIT Wr TERMINAL UNIT EXISTING CONNECT TO EXISTING THERMOSTAT OR TEMP. SENSOR NOTE EQUIPMENT DESIGNATOR BALL VALVE GATE VALVE CHECK VALVE BALANCING VALVE - THERMOMETER DIRECTION OF FLOW PUMP ▪ STRAINER • PRESSURE GUAGE PETE'S PLUG DOUBLE CHECK ASSEMBLY PRESSURE REDUCING VALVE • UNION AFF AHU B.D. BHP BTU CFM CONN. CONT. CW DB DIA. DIST. EA EDB EWB EWT FF FIXT. FPM FPS FT. GA. GPM H HP I.D. IN. L LBS. LDB LWB LWT MAX. MBH MIN. NC N.C. N.I.M. NO. N.O. O.A. P PSI P/T R.A. RECT. REQ'D S.A. S.P. SQ. TEMP. TYP. VAV WB WPD 0 ABOVE FINISH FLOOR AIR HANDLING UNIT BOTTOM OF DUCT BRAKE HORSEPOWER BRITISH THERMAL UNITS CUBIC FEET PER MINUTE CONNECTION CONTINUATION DOMESTIC COLD WATER DRY BULB DIAMETER DISTRIBUTION EXHAUST AIR ENTERING DRY BULB TEMPERATURE ENTERING WET BULB TEMPERATURE ENTERING WATER TEMPERATURE FINISH FLOOR FIXTURE FEET PER MINUTE FEET PER SECOND FEET / FOOT GAUGE GALLONS PER MINUTE HEIGHT HORSEPOWER INSIDE DIAMETER INCHES LENGTH POUNDS LEAVING DRY BULB LEAVING WET BULB LEAVING WATER TEMPERATURE MAXIMUM THOUSANDS OF BTUs PER HOUR MINIMUM NOISE CRITERIA NORMALLY CLOSED NOT IN MECHANICAL NUMBER NORMALLY OPEN OUTSIDE AIR PERSON POUNDS PER SQUARE INCH PRESSURE / TEMPERATURE RETURN AIR RECTANGULAR REQUIRED SUPPLY AIR STATIC PRESSURE SQUARE TEMPERATURE TYPICAL VARIABLE AIR VOLUME WIDTH WET BULB WATER PRESSURE DROP DIAMETER HWS 2-WAY CONTROL VALVE HWR 3-WAY CONTROL VALVE CAP SMOKE DETECTOR • MOTORIZED DAMPER (E) EXISTING (D) DEMOLISH NEW WORK (HWS) HEATING WATER SUPPLY (HWR) HEATING WATER RETURN FIRE DAMPER FIRE / SMOKE DAMPER SMOKE DAMPER SEISMIC BRACING LATERAL BRACING LONGITUDINAL BRACING • LONGITUDINAL & LATERAL BRACING EXHAUST FANS (g) MARK NUMBER TYPE ROOFTOP SYSTEM RESTROOM CFM 300 TOTAL SP. (IN H20) 0.25 RPM 1550 TIP SPEED (FPM) - MOTOR HP 1/25 CONTROLLED BY TIMECLOCK INTERLOCK WITH WHEEL TYPE BI MOTORIZED DAMPER YES ISOLATION INTERNAL DESIGN WEIGHT (LBS) 30 MAX. SONES 4.9 BASIS OF DESIGN GREENHECK G075 NOTES: 1. MANUFACTURER FAN SELECTIONS SHALL INCLUDE EXTERNAL PRESSURE. DROP AND FAN DRIVE LOSS. 2. FAN EF-1 AND EF-2 SHALL BE U.L. LABELED FOR GREASE LADEN VAPOR AND HAVE ALL WELDED HOUSING SEAMS, HIGH EFFIENCY MOTOR, DISCONNECT, WEATHER COVER, DRAIN, SHAFT SEAL, U.L. 762. 3. FAN EF-1 AND EF-2 SHALL BE SUPPLIED WITH HOODS AND INSTALLED. BY THE MECHANICAL CONTRACTOR. SEE HOOD DRAWINGS. RESTAURANT AIR BALANCE CALCULATION MARK SA NUMBER CFM RA CFM OSA EXH CFM CFM EF-1 EF-2 RTU-1 RTU-2 MUA-1 TOTAL BALANCE 3600 300 3000 2000 1000 2500 1500 1000 2718 5500 3500 4718 3900 818 MECHANICAL ENERGY NOTES: C403.2.3.3 Packaged electric heating and cooling equipment. Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20,000 Btu/h shall be a heat pump. Exception: Unstaffed equipment shelters or cabinets used solely for personal wireless service facilities. C403.2.4 HVAC system controls. Each heating and cooling system shall be provided with thermostatic controls as specified in Section C403.2.4.1, C403.2.4.2, C403.2.4.3, C403.2.4.4, C403.4.1, C403.4.2, C403.4.3, C403.4.4, C403.4.5, C403.4.6, C403.4.7, C403.4.8, C403.4.9, or C403.4.10. C403.2.4.1 Thermostatic controls. The supply of heating and cooling energy to each zone shall be controlled by individual thermostatic controls capable of responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. Controls on systems required to have economizers and serving single zones shall have multiple cooling stage capability and activate the economizer when appropriate as the first stage of cooling. See Section C403.3.1 or C403.4.1 for further economizer requirements. Where humidification or dehumidification or both is provided, at least one humidity control device shall be provided for each humidity control system. Exception: Independent perimeter systems that are designed to offset only building envelope heat losses or gains or both serving one or more perimeter zones also served by an interior system provided: 1. The perimeter system includes at least one thermostatic control zone for each building exposure having exterior walls facing only one orientation (within .+/-45 degrees) (0.8 rad) for more than 50 contiguous feet (15,240 mm); and 2. The perimeter system heating and cooling supply is, controlled by a thermostat located within the zones served by the system. C403.2.4.1.1 Heat pump supplementary heat. Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set-up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). Heat pumps equipped with supplementary heaters shall be installed with controls that prevent supplemental heater operation above 40'F. Exception: Packaged terminal heat pumps (PTHPs) of less than 2 tons (24,000 Btu/hr) cooling capacity provided with controls that prevent supplementary heater operation above 40T. C403.2.4.2 Setpoint overlap restriction. Where used to control both heating and cooling, zone thermostatic controls shall provide a temperature range or deadband of at least 5T (2.6C) within which the supply of heating and cooling energy to the zone is capable of being shut off or reduced to a minimum. Exception: Thermostats requiring manual changeover between heating and cooling modes. C403.2.4.3 Off -hour controls. For all occupancies other than Group R, each zone shall be provided with thermostatic setback controls that are controlled by either an automatic time clock or programmable control system. Exceptions: 1. Zones that will be operated continuously. 2. Zones with a full HVAC load demand not exceeding 6,800 Btu/h (2 kW) and having a readily accessible manual shutoff switch. C403.2.4.3.1 Thermostatic setback capabilities. Thermostatic setback controls shall have the capability to set back or temporarily operate the system to maintain zone temperatures down to 55T (13'C) or up to 857E (29'C). C403.2.4.3.2 Automatic setback and shutdown capabilities. Automatic time clock or programmable controls shall be capable of starting and stopping the system for seven different daily schedules per week and retaining their programming and time setting during a Toss of power for at least 10 hours. Additionally, the controls shall have a manual override that allows temporary operation of the system for up to 2 hours; a manually operated timer capable of being adjusted to operate the system for up to 2 hours; or an occupancy sensor. C403.2.4.3.3 Automatic start capabilities. Automatic start controls shall be provided for each HVAC system. The controls shall be capable of automatically adjusting the daily start time of the HVAC system in order to bring each space to the desired occupied temperature immediately prior to scheduled occupancy. C403.2.4.4 Shutoff damper controls. Both outdoor air supply and exhaust ducts shall be equipped with motorized dampers complying with Section C402.4.5.2 that will automatically shut when the systems or spaces served are not in use or during building warm-up, cooldown, and setback. Exceptions: 1. Gravity relief dampers complying with exception 1 to Section C402.4.5.2 serving systems with a design outdoor air intake, relief or exhaust capacity of less than 300 cfm total supply shall be permitted. 2. Gravity dampers shall be permitted for buildings of any height located in Climate Zones 1, 2 and 3. 3. Gravity (nonmotorized) dampers in Group R occupancies where the design outdoor air intake or exhaust capacity does not exceed 300 cfm (142 L/s). 4. Systems serving areas which require continuous operation. 5. Combustion air intakes. 6. Operation of dampers shall be allowed during ventilation prepurge one hour before expected occupancy and for unoccupied period precooling during the cooling season. 7. Dampers are not required in systems where specifically prohibited by the International Mechanical Code. C403.2.5.4.1 Kitchen hoods. Each kitchen area with total exhaust capacity larger than 2,000 cfm shall be provided with make-up air sized so that . at least 50% of exhaust air volume be (a) unheated or heated to no more than 607E and (b) uncooled or cooled without the use of mechanical cooling. Exceptions: 1. Where hoods are used to exhaust ventilation air which would otherwise exfiltrate or be exhausted by other fan systems. A detailed accounting of exhaust airflows shall be provided on the plans that accounts for the impact of any required demand controlled ventilation. VENTILATION AIR SCHEDULE ROOM NUMBER AND NAME DINING HALL KITCHEN COOK/SERVE MENS WENS TOTAL AREA (SQ. FT.) OCCUPANT NUMBER OF LOAD OCCUPANTS (#/1000 SQ. FT.) Az 1550 256 419 462 55 55 2797 100 0 20 20 0 0 Pz 155 0 9 10 0 0 174 OUTSIDE AIR REQUIREMENT (CFM/P) Rp 7.5 7.5 7.5 7.5 0 0 OUTSIDE AIR OUTSIDE AIR ZONE SUPPLY PRIMARY REQUIREMENT REQUIRED (CFM) OSA AIR (CFM) OSA (CFM/SQ FT.) (CFM) FRACTION • Ra Vbz 0.18 0.06 0.18 0.18. 0 '0 1442 15 143 158 0 0 1758 Ez Vo2: Vpz Zp 1.0 1442 3000 0.48 1.0 15 100 0.15 1.0 143 900 0.16 1.0 158 1350 0.12 1.0 0 75 0.00 1.0 0 75 0.00 1758 5500 Vou Vps RETURN EXHAUST Zone AIR (CFM) AIR (CFM) Ventilation Efficiency 3000 100 900 1250 0 0 0 0 0 150 0 - 150 Evz 0.84 1.17 1.16 1.20 1.32 1.32 Corrected OSA CFM 1717.86 18.30 170.32 188.48 0.00 0.00 5250 300 0.84 2095 Ev CORRECTED TOTAL OUTDOOR AIR FLOW RATE 2095 CFM Corrected OSA Fraction Zs = AIR SYSTEMS R1U-1 RTU-2 R1U-2 RTU-2, MAU-1 RTU-2, EF-3 RTU-2, EF-3 0.38 REVIEWED FOR CODE COMPLIANCE APPROVED APR 17 2014 City of Tukwila BUILDING DIVISION 2. Certified grease extractor hoods that require a face velocityno greater than 60 fpm. C403.2.7.1 Ducts, shafts and plenums conveying outside air from the exterior of the building to the mechanical system shall meet all air leakage and building envelope insulation requirements of Section C402, plus building envelope vapor control requirements from the International Building Code, extending continuously from the building exterior to an automatic shutoff damper or heating or cooling equipment. For the purposes of building envelope insulation requirements, duct surfaces shall meet the requirements for metal framed walls per Table C402.1.2. Duct surfaces included as part of the building envelope shall not be used in the calculation of maximum glazing area as described in Section 402.3.1. Exceptions: 1. Outside air ducts serving individual supply air units with Tess than 2,800 cfm of total supply air capacity, provided these are insulated to R-7. 2. Unheated equipment rooms with combustion air louvers, provided they are isolated from conditioned space at sides, top and bottom of the room with R-11 nominal insulation. C403.2.7.2 All other supply and return air ducts and plenums shall be insulated with a minimum of R-6 insulation where located in unconditioned spaces and a minimum of R-8 insulation where located outside the building. Where located within a building envelope assembly, the duct or plenum shall be separated from the building exterior or unconditioned or exempt spaces by minimum insulation value as required for exterior walls by Section C402.2.3. Exceptions: 1. Where located within equipment. 2. Where the design temperature difference between the interior and exterior of the duct or plenum does not exceed 157E .(8'C). Supply ducts which convey supply air at temperatures less than 557E or greater than 1057E shall be insulated with a minimum of R-3.3 insulation where located within conditioned space. All ducts, air handlers, and filter boxes shall be sealed. Joints and seams shall comply with Section 603.9 of the International Mechanical Code. C403.2.7.3 Duct construction. Ductwork shall be constructed and erected in accordance with the International Mechanical Code. C403.2.7.3.1 Low-pressure duct systems. All longitudinal and transverse joints, seams and connections of supply and return ducts operating at a static pressure less than or equal to 2 inches water gauge (w.g.) (500 Pa) shall be securely fastened andsealed with welds, gaskets, mastics (adhesives), mastic -plus embedded -fabric systems : or tapes installed in accordance .with the manufacturer's installation instructions. Pressure classifications specific to the duct system shall be clearly indicated on the construction documents in accordance with the International Mechanical Code. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at static pressures Tess than 2 inches water gauge (w.g.) (500 Pa) pressure classification. 3M FIRE .BARRIER DUCT WRAP 615+ SECTION A -A ■:1ArA:IAll i11llIA.1A1 f4'A.rflflrJE[.i. InV'ArA1J J f1.R1N"lml. `1.S.ltji 11i aA 4A Seddon B-S: Compression Butt Joint 4B Section B-B: But Joint with Collar 4C Section Bic Single End Overlap (Telescope) e..asw.r�l:rw'parrK.a`.+rt'Ay.a1. .rtv,0011.e.res�,_ 40 Section B-B: Dual End OM+ lap (Checkerboard) 1. GREASE DUCT: Use aeontivacuisly-weld L-thaped,rectangidarductsystemwithho:izontal anditertical shafts constructed of 16 GA sheet steel with amaxmn2 inch2area andarrn man 48-inchdinusssian.Wiusizequbed,equipteduct%wdhep[e- fabnc ated access door (Itn 6) or field-fiihricated access door (kern 7). A. rust the grease duct using sectors affixed to each other with weldeffjoints. B. Reinforce diagnose diato.1MCorNEPA.96tequ ▪ ments desWiedto cony the weightofthegre seduct>assetn ly coventwithlvas layeas of insulation.(Item 4) under a fire load equivalenttuthe AS:TME 2336exposeue rind the 119 curve. C. Rigidly support the gicase.duct (ltem 1)asspecitiedi►Rem .5or inaeca®daneewithDACorbiFPA96vdienthase. requ amuents are greater: D. Protect -die amuzla; space around the Brea seduc t (Item 1ypassmg tinnghafite-nited wall assembly with anlnterteir-certified, convalible,3M,penetmionfir topsystem,havingihesame:fieratingasthewall assembly asdescrbedmanManic DesignList Footed -the annular space airomd the gnaw duct (bun1)passing through a fire -sated floor/ceding assm Nyasspecifiedinitem:8. 2. FASTENERS. Weldmmimuin 12 GA, 6-1/2-inch copper -coated, steel insulation phwor 12 GA, Undated cup. head steal pis lobe grease ductQtem 1) Molah die fbllowing.fasf rmetbodwhtia ms©ia m)me@iod. A. ConwessionButtJointLocalepiasataltblmieetaveb's,onallsedesaffceg dud Mein1),anclmeatfollowing.requirements. i. Space pins maudlin= 12 inchesapartin rows alum die width ofgreaseduct Mem I). Locatepins maximsun i-J/4incLes fawn die edges ofthgrease duct (liana Rr+�os-ectinvewA A.. Na/:tJ'>:11if xaty-ilfR `+rdMAI PMEMS I pace liecou offiinsas frillkowc usepdtzunneutinallinilostopakthanzatilanna iwthcsopart,fficniniminal9thalwasiont alongtbeleagth ofiffipgremedueti ftem:1). ferin Itein4AandirmiriaorB411 ui Attrnialibeiion(fiern4A3 s ;PEs n 2-l2a:24 -ins is aleel elf x all ix :Idlemschuddlied, cdtalrathendtandmilkindsiolim(licoviiiyhdrinsthatatcholomg. R. Butt twithenik ::i; Cptha:#altl fdieg e a 1),amtmearitheftillowtignquironenin. iSpacephstoaxidonn 12 imeherraparriarowssursaithewidth ofgreasednegitom _pifla 6- F faunae, edged m '-begs Mon I . Ra erhr sr ► r , -A a:Spacelhe rowsofpins as fellowosepaihe=nn ®alff hichrs,apratihen um:q tharnorninal9inchrsapart almigthel itbevesse tfi 1).Raub te s#i#s view13 m� AIha- aatim:{Dean4 ?lairs- Owe a • 2- .r€.i o s7t ix.Allerclip s mulled, addifatticadhddrailhiaddstiou tYlent4Wtheidattiltidehobiw C. ne 1e Locahpins:alsittledketrrta pa;,,cm. efBre; +datlhands .:l ap :iazarase'assillevidlhof dent on 1.)LIAdatepiatinittialua 614.aoc .fman tdgesofthegirdat Mod a):Wald a ivica A . it_ Spece:l :i ofp ma 10- 1 a indims spud $laeig,'tim:i dolt(hon:l..dhxdat 4 :ae Led : holher, space pmd ahem t-112 .rromli ee dge the ii>ae r: Rocerto seadarviderriBa. Mihi inudadonitlicat4gh eutsltod; p aoe in 2 a24 2- th squid; gaboatizeitatted,scifiodkingudiburchrtauldslt insulationFins. iv Affix efts ma 'ingioThart eeiafatte nd iiush (that thephs thd =holed& 11 DuaiEsedOer (hec bo 4Lx.M pima a#alibtaad[etare spsiaddll sides ofthe,gmasedudthanillizedierettlichillevrihg t ISpa7C1iIIKIMIXiM11111 12 halms apwtinuras acrowithewidth afgleasedsctplam .11: Lank ptimmaximinn 6-314incliestran.ibe. edges ofthegieruc dact(tcm.1).l ia aecdarrviewA,A. iL Swede :1713Wal afphis 10-1,2net=vast along thel .gothedt(ItemI).ilthereilbersofinsulaitiongtem4D)aar butted bgethrr, apasx-pins a maximinn 14i2 bads freattliezdgeeftbrinathtian.leferid Ron-4D scahht.1 8 �i. A u .(Its iststsdle4plaor Rehm- x.2-142,inchiquased4r=ksetr4adkitgasshrdiositartaS EIVED CITY OF TUKWILA ix Atka- &pc me'+»staliod,=fa/ ilctread , :�s,dalfiaee; Iersmtntae'imo , BAYS1N6 PARTNERS FIVE GUYS® BURGERS and FLIES __M Consulting. Engineers 2007 S.E. Ash St. Portland, OR 97214 (503) 234-0548 FAX: (503) 234-0677 IINC.ffi.MFIA-ENG.COM CONTACT: JAMES TORMEY NOTES SUBMITTALS ITEM DESCRIPTION DATE BID AND PLAN REVIEW SET ISSUE 03.15.14 FIVE GUYS BURGERS & FRIES TUKWILA, WA HVAG LEGEND AND SCHEDULES SCALE: NO SCALE PROJ. #: MANAGER: JLT DRAFTSMAN: SKG FLOOR: I APR 0 4 2014 PERMIT CENTER FILE: 878q_M4 6 0 EXH 150 CFM L� ICI' 150 CFM O A. ctt 14" TE7 0 10"0 S 00 CFICoo 36 \ 1TD 18X18 RA 1100 CFM (TYP. OF 2) 01 18x18 SA r 1.0"0 SA 300 CFM C \/ 0 0000l0 000 000 II 0 18"0 J 10"0 SA 225 CFM \ T -/ _/ _J _/ k, i 10"0 A 225CM (TYP. OFj 5) moo. NA, ��`i.•46-0!.' 1 MIN r 16"0 SA 18X18 RA 1500 CFM (TYP. OF 2) SPUN ALUMINUM FAN ENCLOSURE DISCONNECT SWITCH ANCHOR FAN COUNTERFLASHING BASE TO. CURB CURB MOUNTED BACKDRAFT DAMPER HVAC PLAN SCALE: 1/4" = 1'-0" 'i 1 I I r 1 1 1 1 II 1 1 1 1 I11 11 L L 1 ILI '- -1 i FAN WHEEL, MOTOR AND DRIVE ASSEMBLY. 0 0 I% i . .. .. it `.ice �`.i�•`.i. `•i J BIRDSCREEN CURB AND FLASHING 5 ROOF EXHAUST DUCT WHERE APPLICABLE. ANCHOR AND SEAL OFF INSIDE CURB ROOF MOUNT EXHAUST FAN SCALE: NONE SPIN —IN FITTING MAIN SUPPLY DUCT MANUAL VOLUME DAMPER SHEET METAL FLEXIBLE DUCT DUCT. FOR FINAL CONNECTION ONLY. SAME SIZE AS DIFFUSER NECK SIZE. ccgcV C) 1.0<1 16"0 SA 12X6 SA 250 CFM (TYP. OF 12) 16"0 SA 1 PANDUIT STRAP CEILING DIFFUSER SEISMIC / RESTRAINT TAB f (TYPICAL) TYPICAL SUPPLY DIFFUSER — 5 I SCALE:NONE CEILING GENERAL NOTES: 1. COORDINATE LOCATION OF DUCTWORK TO AVOID RECESSED LIGHT FIXTURES. 2. REFERENCE 5 GUYS DESIGN CRITERIA FOR DIFFUSER MODEL TYPE. 3. PROVIDE MANUAL BALANCING DAMPERS ON ALL SUPPLY AND RETURN DIFFUSERS. 4. VERIFY LOCATION OF EXISTING GAS CONNECTION FOR SPACE AND RTU SUPPLY AND RETURN AIR CONNECTIONS. 5. CONTRACTOR TO VERIFY GAS PRESSURE AND GAS PIPING LENGTH BACK METER. VERIFY IF EXISTING RTU'S ARE TO STAY ON EXISTING GAS LINE OR TRANSFERRED TO TENANT GAS PIPING. 6. CONTRACTOR TO VERIFY RTU CAPACITY AND PROVIDE MINIMUM AIR FLOW FOR UNIT IF NOT SHOWN TO BE GREATER ON PLANS. SHEET NOTES: O LOW PRESSURE NATURAL GAS PIPING ABOVE CEILING/MOUNTED FROM STRUCTURE. 02 NATURAL GAS PIPING DOWN IN WALL/CHASE. O LOW PRESSURE NATURAL GAS PIPING ROUTED LOW ON WALL BEHIND KITCHEN EQUIPMENT. O NATURAL GAS SOLENOID VALVE INTERLOCKED WITH EXHAUST HOOD CONTROLS/FIRE SUPPRESSION SYSTEMS. SEE RISER DIAGRAM. O CONNECT TO EXISTING 2 1/2" GAS IN CEILING SPACE. REVIEWED FOR CODE COMPLIANCE = APPROVED APR 17 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 0 4 2014 FIVE OUYS ® BURGERS and FRIES Consulting Engineers 2007 S.E. Ash St. Portland, OR 97214 FAX: (503)) 234-0677 INC. WWW.MFIA-ENG.COM CONTACT: JIM TORMEY NOTES SUSM I TTALS ITEM DESCRIPTION DATE BID AND PLAN REVIEW SET ISSUE 05.18.14 FIVE GUYS BURGERS & FRIES TUKWILA, WA WAG FLAN AND DETAILS SCALE: 1/4" = I'—O" MANAGER: JLT FLOOR: I PERMIT CENTER PRO.J. #: FILE: 878a_M5 DRAFTSMAN: BK6 SHEET: GAS VENT AND COMB AIR UP THRU ROOF FROM WATER HEATER, TERMINATE W/MAUFACTURER VENT KIT. OFFSET 10'0" FROM PARAPET IF VENT EXTENDS ABOVE PARAPET HEIGHT. EXISTING RTU ROOF EQUIPMENT PLAN SCALE: 1/4" = 1'-0" 1035 CFH AT 175 FT 1 1/4" G WATER HEATER 199 MBH (E)2 1/2" G 2" G BELOW ROOF 2" G FRYER GRIDDLE GRIDDLE 0 380 MBH 150 MBH 90 MBH 1 1/2" G GAS RISER DIAGRAM EXISTING RTU 1 1/4" G M 6 DETAIL MAU-1 216 MBH REVIEWED FOR CODE COMPLIANCE APPROVED APR 17 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA BAYS1NGER PARTNE tS FIVE GUYS BURGERS and FRIES Consulting Engineers — 2007 S.E. Ash St. FPortland, OR 97214 PHN: (503) 234-0548 FAX: (503) 234-0677 INC. 'P.MFIA—ENG.COM CONTACT:.11M TORMFY NOTES SUBNII TTALS ITEM DESCRIPTION DATE BID AND PLAN REVIEW SET ISSUE O3.I8.I4 FIVE GUYS BURGERS & FRIES TUKWILA, WA HVAG ROOF PLAN 'SCALE: NO SCALE MANAGER: JLT FLOOR: APR 0 4 2014 PERMIT CENTER PROJ. #: FILE: Sibq_M6 DRAFTSMAN: BKG SI CET: OF -6 HOOD INFORMATION NO. MODEL LENGTH MAX. COOKING TEMP. TOTAL EXH. CFM EXHAUST PLENUM TOTAL SUP CFM SUPPLY PLENUM CONSTRUCTION HOOD CONFIG.HOO ROW FIRE SYSTEM PIPING HOOD HANGING WEIGHT RISER(S) RISER(S) EHOOD ND TO END WIDTFLENG. CFM S.P. WIDTHLENG. CFM S.P. 1 3347 BD-2 9' 0.00" De 0 g• 1800 10" 17" 1800 -1.026" 0 310 SS 4where Exposed LEFT ALONE YES 365 LBS 2 3347 BD-2 9' 0.00" 600 De g 1800 10" 17" 1800 -1.026" 0 433�0p SS where Exposed RIGHT ALONE YES 395 LBS 3 126 MISC-PSP ,. 9 0.00 N/A 0 1359 10" 24" 679 0.245" 433�0p SS Where Exposed ALONE ALONE NO 74 LBS 10 " 24 " 6 9 7 » 0.245 4 126 MISC-PSP 9 0.00 N/A 0 1359 10" 24" 679 0.245" 4330o SS Where Exposed ALONE ALONE NO 74 LBS 10 24"679 0.245 HOOD INFORMATION FILTER(S) LIGHT(S) UTILITY CABINET(S) HOODNO. TYPE QTY.HEIGHTLENGTHQTY. TYPE WIRE GUARD DLOCATION FIRE SYSTEM ELECTRICAL SWITCHES TYPE SIZE MODEL # QUANTITY LOCATION 1 Captrate Solo 3 • 5 Incandescent NO 16,, 20" 2 Captrate Solo 3 1::: 1g: 5 Incandescent NO Top Mount Ansul R102 6 GAL.31111ONU-NS 1 tt 1 Face Mount 3 HOOD OPTIONS HOOD NO. OPTION 1 FIELD WRAPPER 36.00" High Front, Left BACKSPLASH 67.00" High X 216.00" Long RIGHT/ LEFT QUARTER END PANEL 430 SS 1-PINT GREASE CUP 2 FIELD WRAPPER 36.00" High Front, Right RIGHT/ LEFT QUARTER END PANEL 430 SS 1-PINT GREASE CUP BALANCING NOTES: Exhaust Requirements 100-105% OF DESIGN PER HOOD. MEASURED AT THE EXHAUST FILTER WHILE THE FILTER IS INSTALLED Supply Requirements 95-100% OF DESIGN PER SUPPLY PLENUM MEASURED AT THE BOTTOM FACE OF THE PERFORATION (DISCHARGE POINT) IMPORTANT INSTALLATION NOTES: - TOP MOUNT UTILITY CABINET WILL BE PRE -INSTALLED ON HOOD ON RIGHT SIDE WHEN FACING EQUIPMENT IF CEILING HEIGHT IS NOT 10' AFF CONTACT CAPTIVE-AIRE FOR REVISED DRAWINGS AND TO DETERMINE IF TOP MOUNT UTILITY CABINET IS POSSIBLE. - DO NOT INSTALL QUARTER END PANELS BETWEEN HOODS SCOPE OF WORK HOOD(S): PROVIDED BY OWNER. INSTALLED BY GC. FIRE SYSTEM(S): PROVIDED & INSTALLED BY OWNER. EXHAUST FAN(S) PROVIDED BY OWNER. INSTALLED BY GC. MAKEUP AIR UNIT(S): PROVIDED BY OWNER. INSTALLED BY GC. ELECTRICAL CONTROL(S): PROVIDED BY OWNER. INSTALLED BY GC. GC IS RESPONSIBLE FOR COMPLETE START—UP OF EXHAUST FANS AND MAKEUP AIR UNIT PER CAPTIVEAIRE OPERATION & INSTALLATION MANUAL U L. Listed Incandescent Light Fixture -High Temp Assembly 54" 9' 0.00"Nom./9' 0.00"OD 27" 27" PLAN VIEW — Hood #1 9' 0.00 LONG 3347BD-2 WITH FRONT PSP (SUPPLY PLENUM) UTILITY CABINET AND WRAPPERS SHOWN MOUNTED ON TOP OF HOOD WITH PREINSTALLED FIRE -SYSTEM AND ELECTRICAL CONTROLS INCANDESCENT LIGHT FIXTURE EXHAUST RISER 16" CAPTRATE SOLO FILTER WITH HOOK 3" INTERNAL STANDOFF IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED -COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. QUARTER END PANELS (DO NOT INSTALL BETWEEN HOODS) 33" Utility Cabinet 54" 9' 0.00"Nom./9' 0.00"OD 27" PLAN VIEW - Hood #2 9' 0.00" LONG 3347BD-2 WITH FRONT PSP (SUPPLY PLENUM) MISC-PSP (SUPPLY PLENUM) SHIPS LOOSE. MOUNT FLUSH WITH DROP CEILING 0 10' AFF. 2.75'= ---12.00' GREASE DRAIN WITH 1-PINT REMOVABLE CUP 430 SS BACKSPLASH 67" HIGH X 216" LONG EQUIPMENT BY OTHERS SUPPLY RISER WITH VOLUME DAMPER SECTION VIEW — MODEL 3347BD-2 WITH FRONT PSP (SUPPLY PLENUM) 1/2• DN. ALL 'DREAD ROD cONNBCIED TO ROOF MIST THROUGH ANOTHER WONG ANGLE 1/2• DN. IIFAW DUTY NUT ONE ABOVE MO ONE BEIAW HANGING ANGLE *ROD AND NUTS TO BE SUFftED BY INSTALLING CONTRACTOR HANGING MAE IS PRE—PUNc* AT FACTORY HANGING ANGLE DETAIL THE CAPTIVE AIRE MODEL BD -2 HAS BEEN U.L. 710 TESTED, LISTED, AND APPROVED TO EXHAUST A yiNimum OF 140 CFM PER LINAR !FOOT OViR 600 DEGREE COOKING EQIJIPM0NT FDROP CEILING 10' AFF 14.00„ 76.00" ETL LISTING DESCRIPTION BLOCK CAPTIVE-AIRE HOODS ARE 120 90.00" 00" 33" REVIEWED FOR :ODE COMPLIANCE APPROVED APR 17 2014 Clay of Tukwila BUILDING DIVISION Type I Hood Special Inspections Type I hoods and ducts shall be inspected by approved inspection agencies that satisfy the requirements as to qualifications and reliability. Final inspection reports from such approved agencies of the Type I hood and duct shall be accepted by the code official after the special inspections of hood and duct have been completed. (2012 IMC 107.2.4 & IMC 506.3.2.5) BUILT IN COMPLIANCE WITH NFPA #96 Intertek ETL SANITATION LISTED ETL LISTED #3054804-001 RECEIVED CITY OF TUKWILA APR 0 4 2014 PERMIT CENTER FOR QUESTIONS, CONTACT CAPTIVE-AIRE SYSTEMS, INC, STORES NORTH OF FAIRFAX, VA CONTACT: MARK PROFET PHONE (800) 988-0881 EMAIL: REG32@CAPTIVEAIR.COM STORES SOUTH OF FAIRFAX, VA CONTACT: JAYSON NEWMAN PHONE (800) 419-1447 EMAIL: REG28@CAPTIVEAIR,COM FIVE GUYS® BURGERS and FRIES Consulting Engineers " 2007 S.E. Ash St. Portland, . OR 97214 PHN: (503) 234-0548 FAX: (503) 234-0677 INC.WWW.MFIA-ENG.COM CONTACT: JAMES TORMEY NOTES SUBMITTALS ITEM DESCRIPTION DATE BID AND PLAN REVIEW SET ISSUE 03.18.14 FIVE GUYS BURGERS & FRIES TUKWILA, WA HOOD DRAWINS SCALE: 3/4" = I'-O" PROJ. #: MANAGER: .JLT DRAFTSMAN: I3KG FLOOR: I FILE: 878q_M7 CET: GAS LINE MECHANICAL GAS SHUT OFF VALVE PROVIDED BY CAPTIVEAIRE, INSTALLED BY PLUMBING CONTRACTOR. DUCT PROTECTION NOZZLE DETECTORS PLENUM PROTECTION - NOZZLE WIRE PULL IN CONDUIT BY ANSUL CONTRACTOR PULL STATION PIPING SHOULD BE RECESSED IN WALL **--• -••••''' 4111101. I r AGENT TANKS M RELEASE/ BRACKET ASSEMB ELECTRICAL RE -WIRE PACKAGE FAN & LIGHT SWITCHES LY REMOTE MANUAL PULL STATION FLUSH MOUNT TYPICAL FIVE GUYS ANSUL R102 SYSTEM LAYOUT NOTE: FIRE SYSTEM TO INCLUDE ALL NECESSARY PERMITS, FIELD HOOKUP. AND FINAL TEST. NOTE: FIVE GUYS FIRE SYSTEM ENCLOSURE WILL BE FACTORY —MOUNTED ON TOP OF THE RIGHT HOOD 6" CLEAR SPACE ABOVE AND AT LEAST 3-4" STUB OF 1/2" CONDUIT ABOVE TOP OF WALLBOARD WALL BOARD r 1/2" CONDUIT CONCEALED IN WALL BY ELEC. CONTRACOTR NO BENDING OF CONDUIT PERMITTED, ALL TURNS MUST BE TAKEN WITH 90 DEGREE CORNER PULLEYS REMOTE FIRE PULL COVER BY FIRE PROTECTION SYSTEM INSTALLER. R SS SCREW HOLES PU SCREW HOLES ALLOW 1 ORIENTATION CABLE M All CABLE PULLEY & CONDUIT FROM THIS POINT BY FIRE PROTECTION SYSTEM INSTALLER CORNER PULLEY MUST REMAIN ACCESSIBLE FOR FUTURE SERVICE. FIRE WALLS MAY REQUIRE ACCESS PANELS FINISHED. CEILING STANDARD OCTAGON BOX RECESSED IN WALL BY ELEC. CONTRACTOR MAINTAIN ORIENTATION OF JUNCTION BOX AS SHOWN PULL STATION SHALL BE LOCATED A MINIMUM OF 10' WHEN POSSIBLE AND A MAXIMUM OF 20' FROM THE PROTECTED KITCHEN• APPLIANCE(S) WITHIN THE PATH OF EGRESS. -PER NFPA 96. VERIFY WITH LOCAL CODES. 48" - VERIFY HEIGHT AFF WITH APPLICABLE CODES FIR N D L CT1 BOX AND CONDUIT INSTALLED & SECURED BY ELECTRICAL TRADE FIRE SYSTEM INSTALLATION TO BE BY AUTHORIZED ANSUL DISTRIBUTOR „ REVIEWED FOR CODE COMPLIANCE APPROVED APR 17 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA BAYSik iER PARTNERS FIVE alUYS® BURGERS and FRIES Consulting Engineers -15- 2007 S.E. Ash St. Portland, OR 97214 PHN: (503) 234-0548 FAX: (503) 234-0677 INC.WTLMFIA-ENG.COM CONTACT: JAMES TORMEY NOTES SUBM I TTALS ITEM DESCRIPTION . DATE BID AND PLAN REVIEW SET ISSUE 03.18.14 FIVE GUYS BURGERS & FRIES 11.1KWILA, INA HOOD DRA1A4l SCALE: 3/4" = MANAGER: JLT FLOOR: I APR 0 4 2014 PERMIT CENTER PROJ. FILE: 67f3ci_Mf3 DRAFTSMAN: EKG SHEET: OF -a EXHAUST FAN INFORMATION UNIT NO. FAN UNIT MODEL # TAG CFM S.P. RPM H.P. 0 VOLT FLA DISCHARGE VELOCITY WEIGHT (LBS.) 1 NCA14FA FRYER 1800 1.25 1288 1.0 3 208 3.3 125.14 2 CASRE15DD GRILL 1800 1.25 1606 3.0 3 208 9.5 1322 FPM 158.00 GAS FIRED MAKE UP AIR UNIT(S) FAN UNIT NO. FAN UNIT MODEL # CFM S.P. RPM INPUT BTUs OUTPUT BTUs TEMP RISE INPUT GAS PRESSURE GAS TYPE H.P. 0 VOLT FLA WEIGHT (LBS.) 3 Al-D.250-G10 2718 0.500 1263 215903 198631 De g F 9 7"-14" w.c. Natural 2.000 3 208 6.0 582.34 FAN OPTIONS FAN UNIT NO. OPTION (Qty. - Descr.) 1 1 - Grease Box 2 1 - Rain Cap 3 1 - Inlet Pressure Gauge, 0-35" 1 - Manifold Pressure Gauge, -5 to 15" we 1 - Low Fire Start 1 - AC Interlock Relay - 24VAC Coil FAN #3 A1-D.250-G10 - HEATER CURB ASSEMBLIES NO. ON FAN SIZE 1 # 1 23.0"W x 23.0"L x 26.0"H Vented Hinged 2 # 2 23.0"W x 23.0"L x 24.0"H Vented Hinged 3 # 3 21.0"W x 71.0"L x 20.0"H Insulated FAN #1 NCA14FA ***EXHAUST FAN FOR HOOD COVERING FRYERS*** 33 3/4 1 30 1/2 IMPORTANT INSTALLATION NOTES: - ELECTRICAL CONNECTION SHOULD BE MADE ON THE HINGE SIDE OF THE EXHAUST FANS TO ENSURE FANS CAN BE HINGEDFOR CLEANING - RAIN CAP MUST BE FIELD NSTALLED ON FAN #2 AT THE HEIGHT AND ORIENTATION SHOWN ON DETAIL SCOPE OF WORK HOOD(S): PROVIDED BY OWNER. INSTALLED BY GC. FIRE SYSTEM(S): PROVIDED & INSTALLED BY OWNER. EXHAUST FAN(S): PROVIDED BY OWNER. INSTALLED BY GC. MAKEUP AIR UNIT(S): PROVIDED BY OWNER. INSTALLED BY GC. ELECTRICAL CONTROL(S): PROVIDED BY OWNER. INSTALLED BY GC. GC IS RESPONSIBLE FOR COMPLETE START-UP OF EXHAUST FANS AND MAKEUP AIR UNIT PER CAPTIVEAIRE OPERATION & INSTALLATION MANUAL 1. •DIRECT GAS .FIRED HEATED MAKE UP AIR UNIT WITH 10" BLOWER 2. INTAKE HOOD WITH EZ FILTERS 3. DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT 4. GAS PRESSURE GAUGE, 0-35", 2.5" DIAMETER, 1 /4" THREAD SIZE 5. GAS PRESSURE GAUGE, -5 TO +15 INCHES WC., 2.5" DIAMETER, 1 /4" THREAD SIZE 6. LOW FIRE START. ALLOWS THE BURNER CIRCUIT TO ENERGIZE WHEN THE MODULATION CONTROL IS IN A LOW FIRE POSITION. 7. COOLING INTERLOCK RELAY. 24VAC. COIL. 120V CONTACTS. LOCKS OUT BURNER CIRCUIT WHEN AC IS ENERGIZED. 27 3/8" LIFTING LUG 3 3 20" EQUIPMENT CURB 5 9/16" CURB OUTER WALL DISCHARGE OPENING 13 1 /4" 11 1 /2" 3 7/8'' ---t L— _J AIRFLOW FLEX CONDUIT FOR FIELD WI13L G -14 7/8 17 7/8 20 24 3/4 1 23 35 3/4 DUCTWORK BETWEEN EXHAUST BYE OTHERS OD FEATURES: - ROOF MOUNTED FANS - RESTAURANT MODEL - UL705 AND UL762 - AMCA SOUND AND AIR CERTIFIED - WIRING FROM MOTOR TO DISCONNECT SWITCH - WEATHERPROOF DISCONNECT - HIGH HEAT OPERATION 300°F (149°C) - GREASE CLASSIFICATION TESTING NORMAL WLWEUiXgNOHHTIULEAILLEVUXH UPEM SSUTR CFN E49'CUSLY A IESp} RT�INN WHICH HILH GYP��t.^ R AN �A VAPORS AN DAMAGED AT 15 FE CON IWI ���� �H C�ULDNCAUSE OPTIONS GREASE BOX 3" 26" FAN #2 CASRE15DD ***EXHAUST FAN FOR HOOD COVERING GRILLS*** 32 1/8" 42 1 /8" 86 1/2" i 29 3/4" AIRFLOW DISCONNECT) SWITCH DIRECT FIRED MODULE 39 9/16 7-3/4" NPT -3 1 6 1/4" 20" 16 1/4" 1 1 1- I--°- 21 ROOF OPENING 2" SMALLER THEN CURB DIMENSION. BLOWER/MOTOR _ACCESS DOOR 24" SERVICE CLEARANCE REQ. 7' 13/16" 71" AIRFLOW RE SERIES UP BLAST RESTAURANT DUTY UTILITY SET 15 3/8" 28 LOCK & SPRING PIN 0 VENTED CURB 20STEEL GAUGE CONSTRUCTION FLANGE ROOF OPENING 20 DIMENSIONS 20 -�/ l 1 L24 :3/4" RAIN CAP OPTION 22 / 46 1/4" blb deb — 6 1/4" 2" DRAIN- 29 3/8" 14 7/8" 44" 17 7/8" 23" DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) ATTENTION! INSTALLER MUST READ LABEL NEAR DISCONNECT SWITCH! MESSAGE ON LABEL: "INSTALLER SHOULD SUPPLY ENOUGH ELECTRICAL CORD TO LET FAN MAKECOMPLETE SWING FEATURES: - ROOF MOUNTED FANS - RESTAURANT MODEL UL762 - HIGH HEAT OPERATION 300°F (149°C) GREASE CLASSIFICATION TESTING - TILT OUT WHEEL - LOCKING PIN FOR POWER PACK - MOTOR WEATHER COVER - INTERLOCKED DISCONNECT SWITCH NORMAL TEMPERATURE TEST WHILEEXHAUST FAN MUST OPERATE CONTINUOUSLY EXHAUSTING AIR AT 300°F 149°C) U UNTIL ALL FAN PARTS HAVE REAL ED THERMAL IAEQUILIBRIUM, INUGLIEF ECTAND WITHOUTFWHICH WOULD CAUSE UNSAFE OPERATION. ABNORMAL FLARE-UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600°F (316°C FOR A PERIOD OF 15 MINUTE WIT OUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. REVIEWED FOR CODE COMPLIANCE APPROVED APR 17 2014 City of Tukwila BUILDING DIVISION OPTIONS RAIN CAP - V CAP ASSEMBLY FOR CASRE15DD 24" / 20 3" /20 119 VENTED CURB 20STEEL GAUGE CONSTRUCTION FLANGE RECEIVED CITY OF TUKWILA ROOF OPENING �1 DIMENSIONS APR 0 4 201 FIVE GUYS® BURGERS and FRIES MConsulting Engineers F2007 S.E. Ash St. Portland, OR 97214 PHN: (503) 234-0548 FAX: (503) 234-0677 INC.WWW.MFIA-ENG.COM CONTACT: JAMES TORMEY NOTES SUBM I TTALS ITEM DESCRIPTION DATE BID AND PLAN REVIEW SET ISSUE 03.18.14 FIVE GUYS BURGERS & FRIES TUKWILA, WA HOOD DRAIAII NC - SCALE: NONE PROJ. #: MANAGER: JLT DRAFTSMAN: BKG FLOOR: I M-q PERMIT CENTER FILE: 878q_MGI RA NLON R S A A N T RAIN CAP (PROVIDED BY CAPTIVE-AIRE, INSTALLED BY HOOD INSTALLER (MECHANICAL CONTRATOR)) GREASE EXTRACTOR EXHAUST FAN PLUMBER TO ATTACH 2" COPPER PIPE TO A 3" TO 2" REDUCER. \� GENERAL CONTRACTOR TO PROVIDE A HOLE THRU ROOF, AND PITCH POCKET FOR GREASE DRAIN LINE. SEAL HOLE WATERTIGHT THRU ROOF. 2" COPPER PIPE FOR `''GREASE DRAIN LINE PROVIDED AND ROUTED BY PLUMBER EF-2 HINGE ■ 16 2 GREASE DRAIN LINE 2" DIA COPPER TUBE FURNISHED AND. INSTALLED BY PLUMBER. HEAT TAPE FURNISHED BY CAS. /32" 1 /2" THICK INSULATION ABOVE ROOF LINE BY PLUMBER FINISHED CEILING GROUND FAULT PROTECTION PLUG INDICATOR LIGHT GROUND FAULT PROTECTION OUTLET 99 FLOOR AFF 5' 5.0 AFF EAT TAPE ROOF DO NOT INSTALL WITH 90 DEG ELBOWS. USE ONLY 45 DEG ELBOWS. MAINTAIN A MINIMUM SLOPE OF 1/4" PER 1'. RUN HEAT TAPE ALONG BOTTOM OF _COPPER PIPE. 2" COPPER PIPE INSTALLED BY PLUMBER IN OPEN CHASE (BY CAS). STAINLESS STEEL GREASE COLLECTION BOX IT IS THE RESPONSIBILTY OF THE CONTRACTOR TO DETERMINE IF THE GREASE DRAIN SYSTEM IS ACCEPTABLE TO LOCAL CODE AUTHORITIES 12" 6 INSTALLATION PROCEDURE: TRADE RESPONSIBLE 1. THE HEAT TAPE ASSEMBLY IS SHIPPED LOOSE FROM THE EXHAUST FAN. CAS 2. _ THE GENERAL CONRACTOR IS TO PROVIDE HOLE IN ROOF AND SEAL THE HOLE (SEE DIAGRAM). GENERAL CONTRACTOR 3. _ INSTALL THE COPPER GREASE LINE DRAIN PIPE, SUPPLIED BY THE PLUMBER. PLUMBER / ELECTRICIAN 4. _ REMOVE (AND SAVE) THE END CAP AND GROUND FAULT PLUG. (GIVE PARTS TO ELECTRICIAN) PLUMBER 5. ROUTE THE HEAT TAPE ON THE OUTSIDE OF THE COPPER TUBE. PLUMBER 6. SECURE HEAT TAPE AND END CAP TO DRAIN USING CABLE TIE AS SHOWN IN END DETAIL. PLUMBER 7. INSULATE COPPER DRAIN LINE ABOVE THE ROOF LINE. PLUMBER 8. THE ELECTRICIAN IS TO SUPPLY GROUND FAULT PROTECTION OUTLET LOCATED NEAR GREASE COLLECTION BOX (15 AMP, 120 VOLT CIRCUIT) THE POWER SOURCE SHOULD BE A SEPERATE CIRCUIT. THE HEAT TAPE IS TO BE PROTECTED BY G.F.C.I. CIRCUIT BREAKER. THE_ HEAT TAPE STAYS. ON ALL THE TIME, AND IS NOT CONTROLLED BY THE FAN ON —OFF SWITCH. ELECTRICIAN 9. PLUMBER TO MOUNT GREASE COLLECTION BOX ON THE WALL IN PREP AREA. GREASE COLLECTION BOX PROVIDED BY CAS. PLUMBER 10. ELECTRICIAN TO MAKE FINAL CONNECTION BETWEEN GROUND FAULT PLUG AND HEAT TAPE. GROUND FAULT PLUG PROVIDED BY CAS. ELECTRICIAN 11. ELECTRICIAN TO MAKE FINAL CONNECTION BETWEEN END CAP AND HEAT TAPE (ON ROOF). END CAP PROVIDED BY CAS. ELECTRICIAN 12. . HOOD INSTALLER TO MOUNT RAIN CAP ON TOP OF FAN OUTLET. RAIN CAP IS PROVIDED BY CAS. HOOD INSTALLER (MECHANICAL CONTRACTOR) HOLE FOR DRAIN PIPE STAINLESS STEEL GREASE COLLECTION BOX FOR KITCHEN WALL MOUNTING BOTTOM OF FAN AIR GAP 3" PIPE 3" TO 2" REDUCER (BY PLUMBER) CABLE TIE, WRAP AROUND HEAT TAPE AND 2" DRAIN LINE AS SHOWN IN DETAIL. ., • ., 4. • END DETAIL ,, DRAIN FROM FAN HEAT TAPE END CAP 1/2" THICK INSULATION ABOVE ROOF LINE BY PLUMBER HEAT TAPE HEAT TAPE END CAP. HEAT TAPE EXTENDS ABOVE DRAIN PIPE. REVIEWED FOR CODE COMPLIANCE APPROVED APR 17 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 0 4 2014 BAYSINGER PART ERS FIVE GUYS® BURGERS and FRIES Consulting Engineers 2007 S.E. Ash St. Portland, OR 97214 PHN: (503) 234-0548 FAX: (503) 234-0677 INC.1PV9W.MFJA-ENG.COM CONTACT: JAMES TORMEY NOTES SU1E3M I TTALS ITEM DESCRIPTION DATE BID AND PLAN REVIEW SET ISSUE 03.1E3.14 FIVE GUYS BURGERS & FRIES TUKWILA, WA HOOD DRAINING SCALE; NONE PROJ. #: MANAGER: JLT DRAFTSMAN: BK6 FLOOR: I PERMIT CENTER FILE: B7SQ._MIO M-10 ELECTRICAL PACKAGE NO. PACKAGE # LOCATION SWITCHES OPTION FANS CONTROLLED LOCATION QUANTITY TYPE 0 H.P. VOLT FLA 1 321110 NU-NS Top Utility Cabinet Face Mount 1 Light 1. Fan . Exhaust in Fire, FANS ON/OFF Themostatically Controlled Relay w/ DPDT ON/OFF w/ MUA, VFD for manual control of single EF, VFD mounted in Box Exhaust 3 1.0 208 3.3 (RIGHT) Exhaust 3 3.0 208 9.5 Supply 3 2.0 208 6.0 SEQUENCE OF OPERATION - APPLIANCE INTERLOCK - IN AUTO POSITION, FANS WILL TURN ON WHEN TEMPERATURE IS ABOVE 85 DEGREES AND WILL SHUT DOWN WHEN TEMPERATURE COOLS BELOW 85 DEGREES. - IN ON POSITION, FANS WILL REMAIN ON CONSTANTLY - IN FIRE CONDITION, EXHAUST WILL TURN ON OR REMAIN ON. MAKEUP AIR WILL SHUT DOWN AUTOMATICALLY. MUA/ RTU INTERLOCK DETAIL (BY ELECTRICIAN) 24VAC Coil — Signal From Condenser "Call For Cooling Interlock MAKEUP AIR UNIT 27 28 KITCHEN RTU CONDENSER NOTE: THIS CONNECTION WILL LOCK OUT THE MUA BURNER CIRCUIT WHEN A/C IS BEING SUPPLIED TO THE SPACE SCOPE OF WORK HOOD(S): PROVIDED BY OWNER. INSTALLED BY GC. FIRE . SYSTEM(S): PROVIDED & INSTALLED BY OWNER. EXHAUST FAN(S): PROVIDED BY OWNER. INSTALLED BY GC. MAKEUP AIR UNIT(S): PROVIDED BY OWNER. INSTALLED BY GC. ELECTRICAL CONTROL(S): PROVIDED BY OWNER. INSTALLED BY GC. GC IS RESPONSIBLE FOR COMPLETE START-UP OF EXHAUST FANS AND MAKEUP AIR UNIT PER CAPTIVEAIRE OPERATION & INSTALLATION MANUAL MAIN BREAKER PANEL 120V 15AMP NEUTRAL 120V 15AMP NEUTRAL. 3 PHASE 208 VOLT 15 AMP 3 PHASE 208 VOLT 15 AMP FIELD WIRING FACTORY WIRING CAPTIVEAIRE HOOD CONTROL PACKAGE H1 1 H2 N2 Li PRE —WIRE CONTROL CIRCUIT LIGHTING CONTROL CIRCUIT L2 L3 L4 FRYER EXHAUST FAN STARTER T1 T2 T3 SUPPLY FAN STARTER T1 T2 T3 L5 L6 SHUNT TRIP (PROVIDED BY OTHERS) N1 AR1 GRILL EXHAST FAN VFD U2 V2 TR1 C1 W2 TEMPERATURE CONTROLLER S4 S5 EXHAUST FAN #1 DISCONNECT SWITCH SUPPLY FAN DISCONNECT SWITCH EXHAUST FAN #2 DISCONNECT SWITCH BK BN S6 BN TEMPERATURE CONTROLLER S4 S5 S6 R3-1 R3-2 G BK RTD TEMP SENSOR HOOD #1 (LEFT HOOD) RTD TEMP SENSOR HOOD #2 (RIGHT HOOD) GN LS BK WH NO C5 NO C6 C MS-1 Red NO MS-1 . Black FIRE SYSTEM NC MS-1 Brown HOOD LIGHTS HVAC THERMOSTAT(S) G R G R —DRY CONTACTS RATED FOR 11OV/15AMP MAX —INTERLOCKS WITH .EXHAUST FAN. SHUTS OFF IN FIRE CONDITION. C MS-2 Red NO MS-2 Black NC MS-2 Brown BUILDING FIRE ALARM REVIEWED FOR CODE COMPLIANCE APPROVED APR 17 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FIVE GUYS® BURGERS and FRIES Consulting Engineers FE2007 S.E. Ash St. Portland, OR 97214 PHN: (503) 234-0548 FAX: (503) 234-0677 INC. 9PWYP.MFIA—. CONTACT: JAMES TORMEYENGCOM NOTES SU3M I TTAL. S ITEM DESCRIPTION DATE BID AND PLAN REVIEW SET ISSUE 05.18.14 FIVE GUYS BURGERS & FRIES TUKWILA, WA HOOD DRAINING SCALE: NONE MANAGER: JLT FLOOR: I APR 0 4 2014 PERMIT CENTER PROJ. #: FILE: 818q_MI I DRAFTSMAN: BKG / 1 ELECTRICAL SYMBOL LIST 0 a 0 0 D m $3 sK RECESSED FLUORESCENT FIXTURE SURFACE OR PENDANT FLUORESCENT FIXTURE FLUORESCENT STRIP FIXTURE RECESSED DOWN LIGHT WALL MOUNTED FIXTURE PENDANT MOUNTED FIXTURE EXIT SIGN EMERGENCY LIGHT +8'-0" POLE MOUNTED LUMINAIRE TIMECLOCK SWITCH, SINGLE -POLE +48" SWITCH, THREE-WAY +48" SWITCH, KEY OPERATED +48" RECEPTACLE, DUPLEX +18" RECEPTACLE, DUPLEX ABOVE COUNTER ditc RECEPTACLE, DOUBLE DUPLEX EQUIPMENT ELECTRICAL CONNECTION OO JUNCTION ;.:.BOX SPECIAL RECEPTACLE A.F.F. N.L. G.F.I. GND W.P. U.O.N. ABOVE FINISHED FLOOR NIGHT LIGHT GROUND FAULT INTERRUPTER GROUND WEATHER PROOF UNLESS OTHERWISE NOTED a D Eh MAGNETIC STARTER CONTACTOR DISCONNECT SWITCH, NON -FUSED DISCONNECT SWITCH, FUSED ELECTRICAL PANEL, RECESSED ELECTRICAL PANEL, SURFACE MOTOR ELECTRICAL CONNECTION SINGLE -POINT MOTOR ELEC. CONN. 0 PUSHBUTTON STATION FLUSH VALVE SOLENOID 1 7w j FLUSH FLOOR BOX WITH POWER L. - I TELEPHONE & DATA OUTLETS TELEPHONE OUTLET +18" V DATA OUTLET +18" 0 SPRINKLER FLOW SWITCH E SPRINKLER TAMPER SWITCH MAGNETIC DOOR HOLDER DUCT SMOKE DETECTOR HOMERUN TO PANEL _„,--- GROUND CONDUCTOR NEUTRAL CONDUCTOR .�� PHASE CONDUCTOR CONCEALED CONDUIT UNDERGROUND CONDUIT J GENERAL NOTES: A. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF LIGHTING FIXTURES. B. CONNECT EXIT SIGNS AND EMERGENCY LIGHT FIXTURES TO CIRCUIT A-29. C. REFER TO SHEET E3 FOR KITCHEN EQUIPMENT SCHEDULE. D. REFER TO FOOD SERVICE CONSULTANTS DRAWINGS FOR ADDITIONAL POWER REQUIREMENTS PRIOR TO BID AND ROUGH -IN. E. REFER TO ARCHITECTURAL DRAWINGS AND ELEVATIONS FOR LOCATION AND QUANTITY OF RECEPTACLES ON THE OFFICE WALL AND SANDWICH WALL. F. CONTRACTOR TO VERIFY ALL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH -IN. G. REFER TO SHEET E3 FOR MECHANICAL EQUIPMENT SCHEDULE. H. COORDINATE WITH MECHANICAL CONTRACT FOR EXACT LOCATION AND POWER REQUIREMENTS OF ALL MECHANICAL EQUIPMENT PRIOR TO ROUGH -IN. I. VERIFY EXISTING AVAILABLE BUILDING POWER PRIOR TO BID AND ROUGH -IN. 0 POWER PLAN NOTES 1. ELECTRICAL CONTRACTOR SHALL PROVIDE 'GFCI' TYPE RECEPTACLES FOR ALL 15 AND 20 AMPERE 120 VOLT RECEPTACLES IN KITCHEN AREAS NOTED. 2. PROVIDE SHUNT TRIP CIRCUIT BREAKER, INTERLOCKED WITH HOOD FIRE SUPPRESSION SYSTEM SOLENOID VALVE AND EXHAUST AND MAKE-UP AIR FANS, TO DE -ENERGIZE (TRIP) CIRCUIT BREAKER UPON ACTIVATION. 3. GAS SOLENOID VALVE - 120V, 10. INTERLOCK WITH HOOD FIRE SUPPRESSION SYSTEM AND MAKE ALL FINAL CONNECTIONS AS REQUIRED. 4. HOOD FIRE SUPPRESSION SYSTEM - 120V; 10. COORDINATE EXACT LOCATION, MOUNTING HEIGHT AND ELECTRICAL REQUIREMENTS WITH HOOD SYSTEM SUPPLIER PRIOR TO ROUGH -IN. 5 PROVIDE ONE 20A, 120V, 1 P WEATHER PROOF GFIC RATED RECEPTACLE. MOUNT TO THE EXTERIOR OF THE HVAC EQUIPMENT. COORDINATE EXACT MOUNTING LOCATION AND CONDUIT ROUTING IN THE FIELD. PROVIDE CIRCUIT FROM PANEL 'B'. 6. PROVIDE JUNCTION BOX FOR CONNECTION OF EXHAUST HOOD CONTROLS. COORDINATE EXACT LOCATION WITH EQUIPMENT MANUFACTURER PRIOR TO ROUGH -IN. 7. PROVIDE ISOLATED GROUND DUPLEX RECEPTACLE FOR P.O.S. REGISTER AND TICKET PRINTER. MOUNT RECEPTACLE WITH -IN 4' OF UNIT. REFER TO ARCHITECTURAL INTERIOR ELEVATIONS. 8. PROVIDE ISOLATED GROUND DUPLEX RECEPTACLE FOR POINT OF SALE ROUTER. REFER TO ARCHITECTURAL INTERIOR ELEVATIONS. 9. PROVIDE ISOLATED GROUND DUPLEX RECEPTACLE FOR POINT OF SALE SERVER. REFER TO ARCHITECTURAL INTERIOR ELEVATIONS. 10. MANAGERS DESK - REFER TO ARCHITECTURAL INTERIOR ELEVATIONS FOR MOUNTING HEIGHTS OF TELEPHONE/DATA OUTLETS THAT REQUIRE RING AND STRING TO CEILING SPACE. 11. EXTEND ONE (1) 1/2" EMPTY CONDUIT WITH PULL STRINGS FOR DATA WIRING FOR P.O.S. EQUIPMENT AND PRINTER. OLIGHTING PLAN NOTES 1. CONNECT TO HOOD LIGHTS. MOUNT SWITCH ON HOOD. VERIFY EXACT LOCATION. 2. COORDINATE EXACT LOCATION OF SWITCHES WITH OWNER PRIOR TO ROUGH -IN. 3. SET TO TURN OFF LIGHTS TWO MINUTES AFTER MOTION IS DETECTED. 4. CONNECT TO COOLER LIGHTS. LIGHTS BY MANUFACTURER. 5. PROVIDE WEATHERPROOF. JUNCTION BOX AND SNAP SWITCH FOR EXTERIOR SIGN. VERIFY EXACT LOCATION AND REQUIREMENTS WITH SIGN CONTRACTOR. 6. VERIFY EXACT LOCATION OF CONTACTOR WITH OWNER. SEE SHEET E3 FOR CONTACTOR SCHEDULE. 7. CONNECT EMERGENCY LIGHTS AND EXIT SIGNS TO CIRCUIT A-29. 8. PROVIDE JUNCTION BOX AND SNAP SWITCH FOR "OPEN" SIGN. VERIFY EXACT LOCATION AND REQUIREMENTS WITH SIGN CONTRACTOR. 9. NOT USED. 10. PROVIDE CEILING MOUNTED OCCUPANCY SENSOR, LEVITON #OSC-15-10, AND MATCHING POWER SUPPLY OR APPROVED. OCCUPANCY SENSOR TO CONTROL CIRCUIT A-3. 12. ROOF MOUNTED MAKE-UP AIR UNIT. SEE SHEET E3 FOR ELECTRICAL REQUIREMENTS. EXTEND 3#12, 1#12 GROUND IN 3/4" CONDUIT DOWN TO HOOD CONTROL PANEL. COORDINATE ALL REQUIREMENTS WITH SUPPIER PRIOR TO ROUGH -IN. 13. ROOF MOUNTED HOOD EXHAUST FAN., SEE SHEET E3 FOR ELECTRICAL REQUIREMENTS. EXTEND 3#8, 1 #10 GROUND IN 3/4" CONDUIT DOWN TO HOOD CONTROL PANEL. COORDINATE ALL REQUIREMENTS WITH SUPPLIER PRIOR TO ROUGH -IN. 14. HOOD FAN SWITCH MOUNTED ON FACE OF HOOD. COORDINATE WITH HOOD MANUFACTURER. 15. DEVICES SERVING EQUIPMENT LOCATED ALONG THE P.O.S. COUNTER SHALL BE MOUNTED IN THE KNEEWALL. CIRCUITS SHALL BE ROUTED THROUGH THE KNEEWALL TO THE NEAREST FULL HEIGHT WALL AND EXTEND TO PANEL AS REQUIRED. COORDINATE EXACT LOCATION`';. AND MOUNTING HEIGHTS WITH THE ARCHITECTURAL INTERIOR ELEVATIONS..` 16. PROVIDE 2' WIDE X 2' TALL X 3/4" THICK PLYWOOD BACKBOARD FOR TELEPHONE SERVICE ;EQUIPMENT. COORDINATE EXACT MOUNTING LOCATION WITH OWNER'S REPRESENTATIVE IN THE FIELD. MOUNT AS HIGH AS POSSIBLE. 17. NOT USED. 18. TWO 1" CONDUITS UNDER FLOOR FOR POWER WIRING. SAW CUT EXISTING CONCRETE AND PATCH TO MATCH EXISTING. 19. FURNISH AND INSTALL 1" EMPTY CONDUIT WITH PULL STRING FROM P.O.S. DATA OUTLET TO DATA OUTLET AT MANAGERS DESK. 20. DEVICES SERVING EQUIPMENT ALONG THE SANDWICH COUNTER SHALL BE MOUNTED IN THE KNEEWALL CIRCUITS SHALL BE ROUTED THROUGH THE KNEEWALL TO THE CONDUIT INSTALLED UNDER FLOOR AND EXTEND TO PANEL AS REQUIRED. COORDINATE EXACT LOCATION AND MOUNTING HEIGHTS WITH THE ARCHITECTURAL INTERIOR ELEVATIONS. 21. HOOD FIRE SUPPRESSION MANUAL RELEASE PUSHBUTTON WITH CLEAR PLASTIC LIFT COVER. 1 SEPARATE PERMIT APPROVAL REQUIRED RECEIVED CITY OF TUKWILA APR 0 4 2014 PERMIT CENTER NOTES Consulting Engineers -•- 2007 S.E. Ash St. PPHN: ortland, OR 97214 FAX: (503)) 234-06677 INC. WWW.MFIA-ENG.COM . CONTACT: DENISE TAYLOR SUE31\1 I TTALS ITEM DESCRIPTION DATE BID AND PLAN REVIEW 5ET ISSUE 05.18.14 FIVE GUYS BURGERS & FRIES TUK.WILA, WA ELEGTR I GAL. SYM 3OL LIST SCALE: NONE PROJ. #: . MANAGER: RLG DRAFTSMAN: DMT FLOOR: I FILE: &VALE' /7\ (E) POWER CO. METER AND '`="" 400A-3P CIRCUIT BREAKER (E) RETAIL SERVICE SWITCHBOARD 120/208V, 3PH,4W 3000A ) • 3P r EEEI op 0=i c)p op (E) GROUND = #3/0 CU (E) SECONDARY CONDUITS PANEL 'A' TO NEUTRAL/GROUND BOND AT BLDG. SERVICE GND. ONE -LINE DIAGRAM 208Y/120V, 30, 4 WIRE ONE -LINE NOTES 0 1. CONNECT TO (E) UNUSED 200A METERS AND BREAKERS AS REQUIRED. COORDINATE WITH UTILITY COMPANY AS REQUIRED. 2. EXISTING ELECTRICAL SERVICE ENTRANCE AND METERING IS UN-VARIFIED. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS .PRIOR TO THE START OF ANY WORK AND IMMEDIATELY NOTIFY ARCHITECT, IN WRITING, OF ANY DISCREPANCIES. FEEDER SCHEDULE ALUMINUM ) NO. AMPS CONDUIT CONDUCTOR • 13 205A 2-1/21' (4) #250k cm il & (1) #2 GND 0 500A (2) 3" (4):#350kcmi1 ea & (1) #1/0 GND SCHEDULE NOTES: 1. RESIZE GROUND CONDUCTORS FOR PARALLEL FEEDERS AS REQUIRED PER SECTION #250-95 OF THE NEC. INCREASE SIZE OF CONDUIT AS REQUIRED FOR ADDITIONAL GROUNDING. 2. ALL AMPACITIES INDICATED ARE BASED ON ALUMINUM CONDUCTORS WITH 75 C THHN INSULATION. 3. FEEDERS LISTED IN SCHEDULE MAY OR MAY NOT BE A PART OF THIS PROJECT. REFER TO ONE -LINE DIAGRAM FOR FEEDERS REQUIRED. GROUND = #6 CU PANEL ISOLATED GND BAR L 5 GUYS BURGER & FRIES TENANT SPACE MF1A PANEL SCHEDULE 10-Mar-14 panel PANEL A mounting SURFACE location KITCHEN connected load amps 206 voltage 208Y/120V phase 3 bus & main 400A MCB (SCCR: 22K) calculated load amps 219 C service va a/p no. a b c no. a/p va service C 1 LIGHTING 554 20/1 1 * 2 20/1 797 LIGHTING 1 1 LIGHTING 660 20/1 3 * 4 20/1 789 UGHTING 1 1 UGHTING 462 20/1 5 * 6 20/1 540 RECEPTACLES 2 5 BUG UGHT #54 1000 20/1 7 * 8 20/1 1260 RECEPTACLES 2 2 "OPEN" SIGN 1500 20/1 9 * 10 20/1 900 RECEPTACLES 2 2 SIGN 1500 20/1 11 * 12 20/1 100 TIME CLOCK 5 5 ATM SYSTEM 1000 20/1 13 * 14 20/1 1000 SECURITY SYSTEM 5 5 P.O.S. SERVER #8c 1200 20/1 15 * 16 20/1 1000 COMPU1ER/FAX 5 5 P.O.S. MODEM 1000 20/1 17 * 18 20/1 1000 AUDIO SYSTEM 2 5 P.O.S. #8 1200 20/1 19 * 20 20/1 720 PHONE BOARD 5 5 P.O.S #813 1200 20/1 21 * 22 20/1 100 GAS SOLENOID 5 5 HOOD ANSUL SYSTEM 1000 20/1 23 * 24 20/1 100 HOOD CONTROLS 5 5 DUCT SMOKE DETECTOR 100 20/1 25 * 26 50/3 5000 WATER HEATER #36 3 1 P.O.S. PRINTER 8b 200 20/1 27 * 28 * 5000 * 3 1 UGHTING (EMERGENCY) 602 20/1 29 * 30 * 5000 3 6 HOOD EXHAUST FAN EF-1 576 20/3 31 * 32 80/3 0 SPARE 6* 576 * 33 * 34 * 0* 6' 576 * 35 * 36 * 0 * 6 HOOD EXHAUST FAN EF-2 1320 20/3 37 * 38 150/3 10996 PANEL B 7 6* 1320 * 39 * 40 * 9046' 7 6 * 1320 41 * 42 * 12076 * 7 Phase A 25523 VA Phase B 23491 VA Phase C 25276 VA NOTES: line -line voltage 208 largest motor (va) 14436 Total Connected 74290 VA load code: ph. A ph. B ph. C total factor calculated load (va) 1. LIGHTS= 2. RECEPT.= 3. HEATIN 4. KITCHEN= 5. EQUIP.= 6. MOTORS= 7. MISC= 1351 1260 5000 0 5020 1896 10996 1649 2400 5000 0 3500 1896 9046 1064 VA 3040 VA 5000 VA 0 VA 2200 VA 1896 VA 12076 VA 4064 6700 15000 0 10720 5688 32118 1.25 1 + 0.5 1.00 1.00 1.00 * 1.00 5080 6700 15000 0 10720 9297 32118 (* 125% of the largest motor + 100% of the balance) TOTAL = 78915 PANEL 'A' NOTES: 1. PROVIDE LOCK OFF DEVICE ON CIRCUIT BREAKER. MF1A PANEL SCHEDULE 10-Mar-14 panel PANEL B mounting SURFACE location KITCHEN connected load amps 78 voltage 208Y/120V phase 3 bus & main 150A MCB calculated load amps 57 C service va a/p no. a b c no. a/p va service C 6 EXHAUST FAN EF-3 150 20/1 1 * 2 20/1 1800 TEA BREWER #11b 4 4 SODA DISPENSER #12a 1200 20/1 3 * 4 20/1 1200 SODA DISPENSER #12b 4 4 ICE MAKER #14a 1660 20/2 5 6 20/2 1500 ICE MAKER #14b 4 4 * 1660 * 7 8 * 1500 4 4 PREP TABLE 360 20/1 9 * 10 20/1 370 CHEF BASE #19 4 4 WARMER #18 1200 20/1 11 * 12 20/1 100 SHUNT 'TRIP 5 4 GAS GRIDDLE #20a 100 20/1 13 * 14 20/1 110 GAS GRIDDLE #20b 4 5 SHUNT TRIP 100 20/1 15 * 16 20/1 100 SHUNT TRIP 5 4 FRY STATION #21 600 20/1 17 * 18 20/1 900 GAS FRYER #22 4 5 SHUNT TRIP 100 20/1 19 20 20/1 100 SHUNT TRIP 5 4 FRY DUMP STATION #23a 1000 20/1 21 * 22 20/1 1600 FRY STATION UGHTS #23c 4 4 FRY DUMP STATION #23b 1000 20/1 23 * 24 20/1 840 WALK-IN COND. #30b 4 4 BAG 7 BOX #34a 1200 20/1 25 * 26 20/3 1320 HOOD MAKE-UP FAN MAU-1 6 4 WALK-IN. EVAPORATOR 500 20/1 27 * 28 * 1320 * 6 4 ICE MACHINE #57a 1660 20/2 29 * 30 * 1320 * 6 4 * 1660 * 31 * 32 20/1 0 SPARE SPARE 0 20/1 33 * 34, 20/1 0 SPARE SPARE 0 20/1 35 * 36 20/1 0 SPARE SPARE 0 20/1 37 38 20/1 0 SPARE SPARE 0 20/1 39 * 40 20/1 0 SPARE SPARE 0 20/1 41 * 42 20/1 0 SPARE Phase A 9700 VA Phase B 7750 VA Phase C 10780 VA NOTES: line -line voltage 208 largest motor (va) 1692 Total Connected 28230 VA load code: ph. A ph. B ph. C total factor calculated load (va) 1. LIGHTS= 2. RECEPT.= 3. HEATING= 4. KITCHEN= 5. EQUIP.= 6. MOTORS= 7. MISC= 0 0 0 8030 200 1470 0 0 0 0 6230 200 1320 0 0 VA 0 VA 0 VA 9360 VA 100 VA 1320 VA 0 VA 0 0 0 23620 500 4110 0 1.25 1 + 0.5 1.00 0.65 1.00 * 1.00 0 0 0 15353 500 4533 0 (* 125% of the largest motor + 100% of the balance) TOTAL = 20386 0 0 SEPAFIATE PERMIT APPROVAL REQUIRED RECEIVED CITY OF TUKWILA APR 0- 4 2014 BAY -SINGER PARTNERS FIVE GUYS® BURGERS 1-1,61 FRIES NOTES MConsulting Engineers 2007 S.E. Ash St. Portland, OR 97214 PHN: (503) 234-0548 FAX: (503) 234-0677 INC.WWW.IfFIA-ENG.COM CONTACT: DENISE TAYLOR SUBM I TTALS ITEM DESCRIPTION DATE SID AND PLAN R.EVIEIA1 SET ISSUE 03.IS.I4 FIVE GUYS BURGERS & FRIES TUKWILA, WA ONE -LINE 4 PANEL SCHEDULES SCALE: NONE PROJ. #1 MANAGER: RLG DRAFTSMAN: DMT FLOOR; I 12 PERMIT CENTER FILE: ErteAl_f_2 SHEET: OF LIGHTING FIXTURE LIST TYPE LAMP MANUFACTURER CATALOG NUMBER DESCRIPTION OPTIONS A (2) F32T8/ SP41/U6 48 W INDUSTRIAL UGHTING GROUP ILG-R221-UMX-232U6-120 • TYPE :2'X2' TROFFER MOUNTING :RECESSED HOUSING :STEEL LENS/REFL :.125"T. ACRYLIC LENS VOLTAGE :120 BALLAST :ELECTRONIC LENS: SMOOTH SIDE DOWN. WHITE FINISH BW B1W (1) PLS13 - ILG-97040 13 W INDUSTRIAL LIGHTING GROUP ILG-X6519-15BLE TYPE :DECORATIVE PENDANT MOUNTING :PENDANT 8'-6" TO BOTTOM HOUSING :STEEL LENS/REFL :N/A VOLTAGE :120 BALLAST :SELF -BALLAST LAMP WHITE FINISH (INSIDE & OUT) DO NOT PAINT CORD B1W SIMILAR TO BW EXCEPT WITH "TUFF COAT" FINISH • BR B1R (1) PLS13 - ILG-97040 13 W INDUSTRIAL LIGHTING GROUP ILG-X6519-15BLE TYPE :DECORATIVE PENDANT MOUNTING :PENDANT 8'-6" TO BOTTOM HOUSING :STEEL LENS/REFL :N/A VOLTAGE :120 BALLAST :SELF -BALLAST LAMP RED FINISH (INSIDE & OUT) DO NOT PAINT CORD B1R SIMILAR TO BR EXCEPT WITH "TUFF COAT" FINISH C (3) F28T8/ SP41/UMX/ECO 66 W INDUSTRIAL UGHTING GROUP ILG-R241-UMX-428-120 LENS: SMOOTH SIDE DOWN. WHITE FINISH TYPE :2'X4' TROFFER MOUNTING :RECESSED HOUSING :STEEL LENS/REFL :.125"T. ACRYLIC LENS VOLTAGE :120 BALLAST :ELECTRONIC D (5) 22W LED 110 W/FlXT JUNO TRAC-MASTER SERIES ®®HOUSING TYPE :6'-0" TRACK FIXTURE MOUNTING :SURFACE . :STEEL LENS/REEL :N/A 'A VOLTAGE :120V BALLAST :N/A REFER TO ARCHITECTURAL ELEVATIONS FOR MTG. HEIGHT WHITE FINISH MENU BOARD UGHTING E INCLUDED 25 W/FIXT UGHTING BY DESIGN ILG-EU-2-W TYPE :EMERGENCY FIXTURE MOUNTING :WALL (CLOSE TO CLG.) HOUSING :POLYCARBONATE LENS/REFL :N/A VOLTAGE :120 BALLAST :N/A INTEGRAL BATTERY BACKUP 'X' LED GREEN LETTERS 12 W/FIXT. UGHTING BY DESIGN ILG-TP-U-R-W-EM TYPE :EXIT SIGN MOUNTING :WALL HOUSING :THERMOPLASTIC LENS/REFL :N/A VOLTAGE :120 BALLAST :INTEGRAL BATTERY WITH TWO SIDE MOUNT LAMP HEADS 6W EA. LEAD CALCIUM BATTERY GENERAL LIGHTING NOTES A. ALL LIGHT FIXTURES SHALL BE AS SPECIFIED UNLESS OTHERWISE APPROVED. OLIGHTING NOTES 1. JUNO TRAC-MASTER SERIES. MODEL T6 WH , (6'-0" TRACK), T38 WH (END FEED TCLF11 WH CURRENT LIMITER, T253LED-3K-NFL-WH (HEAD), TCL1WH CURRENT LIMITER BREAKER. 2. CONTRACTOR TO PROVIDE ALL NECESSARY COMPONENTS FOR INSTALLATION OF A COMPLETE SYSTEM AS REQUIRED TO MEET DESIGN. KITCHEN EQUIPMENT SCHEDULE 0 NO. EQUIPMENT NAME HP/KW VOLTS PH AMPS CONDUIT WIRE GND CIRCUIT 8 POINT OF SALES SYSTEM 1.2 KW 120V 1 - 1/2" (2)#12 (1)#12 A-19 8a POS PRINTER 0.2 KW 120V 1 - 1 /2" (2)#12 (1)#12 A-21 8b POS TICKET PRINTER 120V 1 1 /2" (2)#12 (1)#12 A-27 8c POS SERVER 1.2 KW 120V 1 - 1 /2" (2)#12 (1)#12 A-15 11 b ICED TEA BREWER 1.8 KW 120V 1 - 1 /2" (2)#12 (1)#12 B-2 12a SODA DISPENSER 1.2 KW 120V 1 - 1/2" (2)#12 (1)#12 B-3 12b SODA DISPENSER 1.2 KW 120V 1 - 1/2" (2)#12 (1)#12 B-4 14a ICE MAKER - 208V 1 16.0 A 1/2" (3)#12 (1)#12 B-5,7 ®3 14b ICE MAKER - 208V 1 16.0 A 1/2" (3)#12 (1)#12 B-6,8 03 18 COUNTERTOP WARMER - 120V 1 10.0 A 1 /2" (2)#12 (1)#12 B-11 19 CHEF BASE - 120V 1 3.1 A 1/2" (2)#12 (1)#12 B-10 20a GAS GRILL IGNITOR - 120V 1 0.7 A 1/2" (2)#12 (1)#12 B-13 20b GAS GRILL IGNITOR - 120V 1 0.9 A 1 /2" (2)#12 (1)#12 B-14 21 FRY STATION - 120V 1 0.5 A 1/2" (2)#12 (1)#12 B-17 22 GAS FRYER IGNITOR - 120V 1 2.1,5.4 A 1/2" (2)#12 (1)#12 B-18 23a FRY STATION - 120V 1 5.0 A 1 /2" (2)#12 (1)#12 B-21 23b FRY STATION - 120V 1 5.0 A 1 /2" (2)#12 (1)#12 B-23 23c FRY STATION - 120V 1 5.0 A 1 /2" (2)#12 (1)#12 B-22 30a COOLER EVAPORATOR - 120V 1 4.2 A 1 /2" (2)#12 (1)#12 B-27 30b COOLER CONDENSER - 120V 1 7.0 A 1/2" (2)#12 (1)#12 B-24 34a BAG-N-BOX - 120V 1 :.' 5.0 A 1 /2" (2)#12 (1)#12 B-25 36 WATER HEATER 15KW 208V 3 3/4 (3)#6 (1)#10 A-26,28,30 54 BUG LIGHT - 120V 1 5.0 A 1 /2" (2)#12 (1)#12 A-7 57a ICE MAKER - 208V 1 16.0 A 1/2" (3)#12 (1)#12 B-29,31 KITCHEN EQUIPMENT NOTES 0 1. VERIFY EXACT REQUIREMENTS WITH KITCHEN DRAWINGS PRIOR TO ROUGH -IN OR PURCHASE OF ELECTRICAL EQUIPMENT. 2. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO EQUIPMENT. 3. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL CORD AND PLUG SET. 4. EQUIPMENT SHALL BE FURNISHED AND INSTALLED BY FOOD SERVICE EQUIPMENT CONTRACTOR. MECHANICAL EQUIPMENT SCHEDULE NO. EQUIPMENT NAME HP/KW VOLTS PH AMPS CONDUIT WIRE GND CIRCUIT EF-1 HOOD EXAUST FAN NO. 1 1 HP 208 3 1/2" 3#12 1 #1 2 A-31,33,35 EF-2 EXAUST FAN NO. 2 3 HP 208 3 - 1/2" 2#12 1 #1 2 A-37,39,41 EF-3 EXAUST FAN NO. 3 1 /25 HP 120 1 - 1/2" 2#12 1#12 B-1 MAU-1 MAKE UP AIR UNIT NO. 1 2.0 HP 208 3 1/2" 3#12 1#12 B-26,28,30 CONTACTOR SCHEDULE CONTACTOR NUMBER CIRCUITS CONTROLLED LIGHTING FIXTURES LOCATION LIGHTING CONTACTOR DESCRIPTION #1 #2 ON, BY T.C. OFF, BY T.C. A-11 A-9 SIGN "OPEN" SIGN FRONT OF BLDG. FRONT OF BLDG. 4 POLE, 120V CONTROL. ASCO 917 SERIES, OR APPROVED. SEE POWER NOTE® , SHEET El SEE POWER NOTE®, SHEET El SEE POWER NOTE®, SHEET El SEE POWER NOTE®, SHEET El SEE POWER NOTE®, SHEET El SEPARATE PERMIT AND APPROVAL 1 REQUIRED RECEIVED CITY OF TUKWILA. APR 0 4 2014 BAYS i . 6. E TR NOTES M Consulting Engineers Portland, OR 97214 2007 S.E. Ash St. .±1 PHN: (503) 234-0548 FAX: (503) 234-0677 INC. WWW.MFIA-ENG.COM CONTACT: DENISE TAYLOR SUE3M I TTALS ITEM DESCRIPTION DATE BID AND PLAN REVIEW SET ISSUE 05.18.14 FIVE GUYS BURGERS & FRIES TUKWILA, WA i SHT I NS.. F I XT. 4 EQUIP. SCHEDULES SCALE: NONE PROJ. #: MANAGER: RLG DRAFTSMAN: DMT FLOOR: 1 PERMIT CENTER FILE: 8-18q_E3 4:A CET: OF INASH OOM - MOUNT KITCHFNI I102,1 PANEL 'A' PANEL 'B' :KA NUM 106 1 POWER & SIGNAL PLAN SCALE: 1 /4" = 1'-0" RECEPT. ABOVE GLAZING. VERIFY EXACT LOCATION (TYP) EXISTING RTU CONTRACTOR TO VERIFY EXISTING ' CONDITIONS AND WHETHER EQUIPMENT POWER CONNECTION(S) SHALL REMAIN UNCHANGED OR TRANSFERRED TO THE TENANT'S PANEL. 101 A-6 (PC) VIA TIMECLOCK A-8 4) A-6 (PC) VIA TIMECLOCK RECEPT. ABOVE GLAZING. VERIFY EXACT LOCATION (TYP) 2 LIGHTING PLAN E4 SCALE: 1/4" = 1'-0" (TYPICAL) A— 9 ACT 0 1, o ABOVE C 0 '• WP ^ILING A-11 VI CONTACT E CEILING VII4 OR A-11 CONTAC WP /IA • ' oNTACTOR ABOVE CEILING SSEPARATE P R tTAND ov RECEIVED CITY OF TUKWILA APR 0 4 2014 NOTES MConsulting Engineers 2007 S.E. Ash St. Portland, OR 97214 PHN: (503) 234-0548 FAX: (503) 234-0677 CONTACT: DENISE TAYLOR ITEM DATE BID AND PLAN REVIEW SET ISSUE FIVE GUYS BURGERS & FRIES SCALE: NONE PROJ. #: MANAGER: RLC DRAFTSMAN: DMT FLOOR: I PERMIT CENTER