HomeMy WebLinkAboutPermit M14-0084 - BAY VALVE SERVICE - ROOFTOP COOLING/GAS HEAT UNITBAY VALVE
SERVICE INC
4385 S 133 ST
EXPIRED
11/09/2014
M14-0084
Parcel No:
Address:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
2613200130
4385 S 133 ST
Project Name: BAY VALVE SERVICE, INC.
MECHANICAL PERMIT
Permit Number:
Issue Date:
Permit Expires On:
M14-0084
5/13/2014
11/9/2014
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
SEBCO INC
4020 E MADISON ST #320 , SEATTLE,
WA, 98112
MARK SMELTZER
112 CENTRAL AVE S , KENT, WA,
98032
PERFORMANCE HEATING & A/C INC
7649 S 180 ST, KENT, WA, 98032
PERFOHA150RT
III
Phone: (425) 251-0356
Phone: (425) 251-0356
Expiration Date: 4/30/2015
DESCRIPTION OF WORK:
REPLACE FAILING 4-TON ROOFTOP PACKAGE COOLING/GAS HEAT UNIT WITH LIKE FOR LIKE UNIT IN THE SAME
LOCATION. CONNECT NEW UNIT TO EXISTING DUCTS, POWER SUPPLY, AND OTHER UTILITIES.
Valuation of Work: $8,000.00
Type of Work: REPLACEMENT
Fuel type: GAS
Fees Collected: $298.16
Electrical Service Provided by: SEATTLE CITY LIGHT
Water District: 125
Sewer Distric: TUKWILA SEWER SERVICE,VALLEY VIEW
SEWER SERVICE
Current Codes adopted by the City of Tukwila:
Internations Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
Permit Center Authorized Signature:
2012
2012
2012
2012
International Fuel Gas Code:
WA Cities Electrical Code:
WA State Energy Code:
2012
2012
2012
Date: :1EI'-13-"
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature:
Print Name:
GIL (2V'iE
Date: SA3/020/V
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or
if the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
2: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
3: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector
based on satisfactory completion of this requirement.
4: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the
City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or
other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
7: ***MECHANICAL PERMIT CONDITIONS***
8: All mechanical work shall be inspected and approved under a separate permit issued by the City of
Tukwila Permit Center (206/431-3670).
9: Manufacturers installation instructions shall be available on the job site at the time of inspection.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
0703 MECH EQUIP EFF
1800 MECHANICAL FINAL
0705 REFRIGERATION EQUIP
0701 ROUGH -IN MECHANICAL
CITY OF TUKW_ _
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://wvvw.TukwilaWA.gov
Mechanical Permit No. Mlq-06111
Project No.
Date Application Accepted:
Date Application Expires:
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION
Site Address:
Tenant Name:
4385 S 133rd St, Tukwila, WA 98168
BAY VALVE SERVICE, INC
PROPERTY OWNER
Name: SEBCO INC
Address: 4385 S 133RD St
City: Tukwila
State: WA
Zip: 98168
CONTACT PERSON — person receiving all project
communication
Name: Mark Smeltzer
Address: 1012 Central Ave S
City: Kent State: WA Zip: 98032
Phone: (425) 251-0356 Fax: (253) 867-5775
Email: mark@pmghvac.com
King Co Assessor's Tax No.: 261320-0133
Suite Number: Floor: 1
New Tenant: ❑ Yes ❑✓ ..No
MECHANICAL CONTRACTOR INFORMATION
Company Name: Performance Mechanical Group
Address: 1012 Central Ave S
City: Kent State: WA Zip: 98032
Phone: (425) 251-0356 Fax: (253) 867-5775
Contr Reg No.: PERFOHA15ORT Exp Date: 04/30/2015
Tukwila Business License No.: BUS-0994165
Valuation of project (contractor's bid price): $ 8,000
Describe the scope of work in detail:
Replace failing 4 ton Rooftop Package Cooling/Gas Heat Unit with like -for -like unit in the same location. Connect new unit to
existing ducts, power supply and other utilities.
Use: Residential: New ❑ Replacement ❑
Commercial: New ❑ Replacement
Fuel Type: Electric ❑
Gas !
Other:
H:\Applications\Forms-Applications On Line\201 1 Applications\Mechanical Permit Application Revised 8-9-1 l.docx
Revised: August 2011
bh
Page 1 of 2
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Furnace >l 00k btu
Floor furnace
Suspended/wall/floor
mounted heater
Appliance vent
Repair or addition to
heat/refrig/cooling
system
Air handling unit
<10,000 cfm
1
Unit Type
Qty
Air handling unit
>10,000 cfm
Evaporator cooler
Ventilation fan
connected to single duct
Ventilation system
Hood and duct
Incinerator — domestic
Incinerator —
comm/industrial
Unit Type
Qty
Fire damper
Diffuser
Thermostat
Wood/gas stove
Emergency generator
Other mechanical
equipment
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED 4G
Signature:
Print Name: Mark Smeltzer
Mailing Address: 1012 Central Ave S
Date: 04/15/2014
Day Telephone: (425) 251-0356
Kent WA 98032
City State Zip
H:'Applications\Forms-Applications On Line12011 Applications\Mechanical Permit Application Revised 8-9-11.docx
Revised: August 2011
bh
Page 2 of 2
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
ACCOUNT QUANTITY I
PAID
$24082
M14-0084 Address: 4385 S 133 ST
Apn: 2613200130
$240.82
MECHANICAL
$229.35
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$196.85
TECHNOLOGY FEE
$11.47
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R2111
R000.322.900.04.00
$11.47
$240.82
Date Paid: Tuesday, May 13, 2014
Paid By: GIL ROMERO PERF MECH GROUP
Pay Method: CREDIT CARD 844183
Printed: Tuesday, May 13, 2014 1:09 PM 1 of 1
SYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
ACCOUNT
QUANTITY I PAID
$57.34
M14-0084 Address: 4385 S 133 ST Apn: 2613200130
$57.34
MECHANICAL
$57.34
PLAN CHECK FEE
TOTAL FEES PAID BY RECEIPT: R1821
R000.322.102.00.00
$57.34
$57.34
Date Paid: Wednesday, April 16, 2014
Paid By: PERF. MECH. GROUP
Pay Method: CREDIT CARD 736812
Printed: Wednesday, April 16, 2014 9:42 AM 1 of 1
SYSTEMS
FILE COPY
CCarrie�
United Technologies
SUBMITTAL
Project
-Untitled2
Date
Tuesday, March 18, 2014
REVIEWED FOR
CODE COMPLIANCE
APPROVED
APR 2 2 2014
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKkikii�h
APR 1 6 2014
PERMIT CENTER
M I'4OO1
Table Of Contents
Project:-Untitled2
Prepared By:
rg"
01111,
03/18/2014
04:57PM
4 Ton 3
Unit Report
Certified Drawing 5
Performance Summary 7
Unit Feature Sheet 10
,jj, :if) M1;'r
" - 4
Packaged Rooftop Builder* 1.39
Page 2 of 10
4 Ton
Project:-Untitled2
Prepared By:
03/18/2014
04:57PM
4 Ton
Tag Cover Sheet
Unit Report
Certified Drawing
Performance Report
Unit Feature Sheet
Packaged Rooftop Builder 1.39g Page 3 of 10
Unit Report For 4 Ton
Project:-Untitled2
Prepared By:
03/18/2014
04:57PM
Unit Parameters
Unit Model. 48TCDA05A2A6-0A0A0
Unit Size. 05 (4 Tons)
Volts -Phase -Hertz. 460-3-60
Heating Type• Gas
Duct Cfg- Vertical Supply / Vertical Return
Low Heat
Round Tube Plate Fin Coils
Lines and Filters
Gas Line Size. 1/2
Condensate Drain Line Size- 3/4
Return Air Filter Type- Throwaway
Return Air Filter Quantity. 2
Return Air Filter Size- 16 x 25 x 2
Unit Configuration
Medium Static Option
AI/Cu - AI/Cu
Base Electromechanical Controls
Standard Packaging
Warranty Information
1-Year parts(std.)
5-Year compressor parts(std.)
10-Year heat exchanger - Aluminized(std.)
No optional warranties were selected.
Dimensions (ft. in.) & Weight (Ib.) ***
Unit Length- 6' 2.375"
Unit Width. 3' 8"
Unit Height. 2' 9.375"
*** Total Operating Weight 597 Ib
*** Weights and Dimensions are approximate. Weight does
not include unit packaging. Approximate dimensions are
provided primarily for shipping purposes. For exact
dimensions and weights, refer to appropriate product
data catalog.
NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods.
Ordering Information
Part Number
Description
Quantity
48TCDA05A2A6-0A0A0
Rooftop Unit
1
Base Unit
Electromechanical control, No intake or exhaust option
None
Accessories
CRECOMZR020A02
Vertical EconoMi$er IV with solid-state controller
1
Packaged Rooftop Builder 1.39g
Page 4 of 10
Certified Drawing for 4 Ton
Project: "-Untitled2
Prepared By:
03/18/2014
04:57PM
NOTES:
1. DIMENSIONS ARE IN INCHES DIMENSIONS
IN [ ] ARE IN MILLIMETERS.
2. CENTER OF GRAVITY
3. apor, DIRECTION OF AIR FLOW
UNIT
48TC-A04
(48TC-A05
48TC-A06
33 3/8
[8471
33 3/6
[847]
18 5/8
[4121
14 1/8
[3711
33 3/8
[8471
147/8
[3711
48TC-A07
41 3/8
[1051]
14 7/8
[3711
FILTER ACCESS PANEL
(TOOL -LESS)
•
COND.
ACCESS
• PANEL '
C=
CONDENSER
COIL
INDOOR COIL
ACCESS PANEL '
3-3/4 J
[95]
BACK
CONDENSER
COIL
OPTIONAL
FACTORY
INSTALLED
CONVENIENCE
OUTLET
46 3/4
[11871
LEFT
44
2-5/8 —
[67]
TYP
CURB
WIDTH
4-5/8
[1181
LECTRICAL
DISCONNECT
LOCATION
19 1/2
6-5/8
[168]
32 1/4
[8181
4,
18-1/8 I
[4591
1 t
16-1/8 1/-1/4 12-1/4
I [/11] [383] [312]
N SEE THRU THEJ
UASE"CHART s_
33 3/8
[8481
C
UNITED P.O. BOX 4608
TECHNOLOGIES SYIAONSE, n
CARRIER TS UI
THIS DOCUMENT IS THE PROPERTY 00 CARRIER CORPORATION
AID IS DELIVERED WON THE EXPRESS CONDITION THAT THE
CONTENTS WILE NOT RE DISCLOSED 01 USED NITXONI CARRIER
CORPORATION'S WRITTEN COGENT.
SWNIESEON W THESE DRAWINGS OR DOCUMENTS
DOES NOT CONSTITUTE PART PERFORMANCE OR
ACCEPTANCE OF CONTRACT.
ECONOMIZER HOOD
(OPTIONAL)
25-5/8
[652]
RETURN AIR
0
E ALT.
CONDENSATE
DRAIN OPENING
IN DASEPAN
17-3/4
[4511
SUPPLY
AIR
• �6-1/4
� 1571
•
16
[406]
10-7/8
[2771
26-1/2
[6 3]
RETURN
AIR
28.3/8 111011.
[7471 SUPPLY
AIR
OPTIONAL
FACTORY
INSTALLED
DISCONNECT
25
[636]
4
[100]
LUE
HOOD
TOP
3-3/8
12-1/8 [851
[3071
�-- 10-1/2 -ww
[4101
CONTROL 80X INDOOR BLOWER
ACCESS PANEL ACCESS
HANDLE
118881
FRONT
ANDLE
CONNECTION SIZES
A
1 3/8' [351 DIA FIELD POWER SUPPLY HOLE
8
2' [501 DIA POWER SUPPLY KNOCKOUT
C
1 3/4' [511 DIA GAUGE ACCESS PLUG
0
7/8' [221 DIA FIELD CONTROL WIRING HOLE
6
3/4'-14 NPT CONDENSATE DRAIN
F
1/2'-11 NPT GAS CONNECTION
G __2
1/2 ' 1641 DIA POWER SUPPLY KNOCK -OUT
THRU-THE-RA E CHART
THESE HOLES REQUIRED FOR USE
CRBTMPWR00IA01, 003A01
THREADED
WIRE
REO'D HOLE
CONDUIT SIZE
USE
SIZES (MAX.)
1/2'
ACC.
7/8' [22.21
X
1/2'
244
7/8" [22.21
Y I
3/4' 1001,003)
POWER
1 1/8' [28.4]
ZNN
(0031 1/2' FPT
GAS
1 3/16' [30.01
FOR 'THRU-THE-BASEPAN' FACTORY OPTION,
FITTINGS FOR ONLY I.Y, 8 Z ARE PROVIDED
SELECT EITHER 3/4' OR 1/2'
N
FOR POWER, DEPENDING ON WIRE SIZE
WP
(001) PROVIDES 3/4" FPT THRU CURB
FLANGE N FITTING.
[2651
(-1/4 1- 1321
E STD. —
CONDENSATE
DRAIN
}
11-3/8
[289]
6.1/8
11551
1—
[1681 [1711
26 3/4 —
[681] 31 1/4
[793]
18.3/4 ww
14271 11
SUPPLY AIR (gyp)
JI�Y
25-I/8
[6381
RETURN
AIR
6
[152]
SUPPLY
AIR RETURN
RIGHT
ILTER
IOUTSIDE
AIR
//4 21-1
15391
11
Jr
BAROMETRIC
RELIEF
FLOW
SHEET
1 OF 2
DATE
11-24-08
SUIERCEDES
09-29-08
48TC 04-07 SINGLE ZONE ELECTRICAL
COOLING WITH GAS HEAT
48TM500993
1Er
5.0
Packaged Rooftop Builder 1.39g
Page 5 of 10
Certified Drawing for 4 Ton
Project:-Untitled2
Prepared By:
03/18/2014
04:57PM
AC-1
UNIT
STD. UNIT
WEIGHT
CORNER
WEIGHT (A)
CORNER
WEIGHT (B)
CORNER
WEIGHT (C)
CORNER
WEIGHT (D)
C G.
HEIGHT
LBS.
KG.
LBS.
KG.
LBS.
KG.
LBS.
KG.
LBS.
KG.
K
Y
Z
487C-804
483
219
111
50
125
57
131
59
116
53
39 19911
23 15841
16 3/8 [416]
(487C-805
537
244
124
56
139
63
145
66
129
59
39 19911
23 [5841
17 [4321 1
481C-806
569
258
131
59
147
67
154
70
131
62
39 (9911
23 [5841
17 1/4 (4381
481C-A01
652
296
150
68
169
76
176
80
157
71
39 19911
23 [5841
20 1/8 15111
0
UNITED P.O. 80A A606
TECHNOLOGIES MERCURE, RI
CARRIER 13221
IRIS HOOKER! IS TOE PROPERTY 00 CARRIER CORPORATION
AND IS OELIYEIED UPON THE ESPRESS CONDITION THAT THE
CONTENTS WILL ROT DE DISCLOSED OR USED WITHOUT CARRIER
CORPORATION'S WRITTEN CONSENT.
SU6MIS6I01 OF THESE DRAWINGS OR DOCUMENTS
DOES R01 C015TITUTE PART PERFORMANCE 02
ACCEPTANCE OF COITRACT.
CORNER A CORNER 8
TOP
A•
uuIui !
CORNER C
D..M
I I
O
: 00•
FRONT
WEIGHT (WT) calc, LBS
BASE UNIT WT 537
ECONOMIZER 50
CURB ADAPTER 167
EXSTG ROOF CURB.. 125
MISC 10
TOTAL WT 889.
SHEET
2 OF 2
DATE
11-24-08
SUMMER
09-29-08
48TC 04-07 SINGLE ZONE ELECTRICAL
COOLING WITH GAS HEAT
48TM500993
REY
5.0
Packaged Rooftop Builder 1.39g Page 6 of 10
Performance Summary For 4 Ton
Project:—Untitled2
Prepared By:
03/18/2014
04:57PM
Part Number:48TCDA05A2A6-0A0AO
ARI SEER- 13.00
Base Unit Dimensions
Unit Length. 74.4 in
Unit Width- 44.0 in
Unit Height. 33.4 in
Operating Weight
Base Unit Weight- 537 Ib
Medium Static Option. 10 Ib
Accessories
Vertical EconoMi$er IV with solid-state controller. 50 Ib
Total Operating Weight. 597 Ib
Unit
Unit Voltage -Phase -Hertz. 460-3-60
Air Discharge. Vertical
Fan Drive Type. Belt
Actual Airflow. 1600 CFM
Site Altitude. 0 ft
Cooling Performance
Condenser Entering Air DB• 95.0 F
Evaporator Entering Air DB. 80.0 F
Evaporator Entering Air WB. 67.0 F
Entering Air Enthalpy. 31.44 BTU/Ib
Evaporator Leaving Air DB. 60.2 F
Evaporator Leaving Air WB- 57.7 F
Evaporator Leaving Air Enthalpy. 24.83 BTU/Ib /
Gross Cooling Capacity. 47.60 MBH
Gross Sensible Capacity- 34.22 MBH
Compressor Power Input- 3.31 kW
Coil Bypass Factor. 0.246
Heating Performance
Heating Airflow- 1600 CFM
Entering Air Temp• 70.0 F
Leaving Air Temp- 104.1 F
Gas Input Capacity 72.0 MBH
Gas Heating Capacity- 59.00 MBH
Temperature Rise. 34.1 F
Supply Fan
External Static Pressure. 1.00 in wg
Options / Accessories Static Pressure
Economizer 0.07 in wg
Total External Static. 1.07 in wg
Fan RPM. 1164
Fan Power 1.13 BHP
NOTE Selected IFM RPM Range: 770 -1175
Electrical Data (Before July 30, 2012)
Minimum Voltage. 414
Maximum Voltage- 506
Compressor RLA. 6.2
Compressor LRA• 41
Outdoor Fan Motor Qty. 1
Outdoor Fan FLA (ea). 0.8
Packaged Rooftop Builder 1.39g Page 7 of 10
Performance Summary For 4 Ton
Project:-Untitled2
Prepared By:
03/18/2014
04:57PM
Indoor Fan Motor Type. MED
Indoor Fan Motor FLA• 2.1
Combustion Fan Motor FLA (ea). 0.24
Power Supply MCA. 10.7
Power Supply MOCP (Fuse or HACR)• 15
Min. Unit Disconnect FLA. 10
Min. Unit Disconnect LRA• 49
Electrical Convenience Outlet None
Electrical Data (July 30, 2012 and Beyond)
Indoor Fan Motor FLA• 2.6
Power Supply MCA. 12
Power Supply MOCP. 15
Disconnect Size FLA. 11
Disconnect Size LRA. 52
July 30th and beyond units can be identified by serial number 3112XXXXXXXXX and higher
Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage
Acoustics
Sound Power Levels, db re 10E-12 Watts
Discharge Inlet Outdoor
63 Hz 88.1 88.0 90.9
125 Hz 82.7 79.8 84.6
250 Hz 74.7 66.4 79.5
500 Hz 70.4 64.0 77.9
1000 Hz 66.9 63.2 76.5
2000 Hz 61.5 57.2 71.1
4000 Hz 63.2 52.8 66.9
8000 Hz 58.6 45.6 62.5
A -Weighted 74.0 69.4 81.0
Advanced Acoustics
Advanced Accoustics Parameters
1. Unit height above ground. 30.0 ft
2. Horizontal distance from unit to receiver 50.0 ft
3. Receiver height above ground- 5.7 ft
4. Height of obstruction. 0.0 ft
5. Horizontal distance from obstruction to receiver 0.0 ft
6. Horizontal distance from unit to obstruction. 0.0 ft
v
Detailed Acoustics Information
Packaged Rooftop Builder 1.39g Page 8 of 10
Performance Summary For 4 Ton
Project:-Untitled2
Prepared By:
03/18/2014
04:57PM
Octave Band Center Freq. Hz
63
125
250
500
1 k
2k
4k
8k
Overall
A
90.9
84.6
79.5
77.9
76.5
71.1
66.9
62.5
92.4 Lw
B
64.7
68.5
70.9
74.7
76.5
72.3
67.9
61.4
80.8 LwA
C
58.5
52.2
47.1
45.5
44.1
38.7
34.5
30.1
60.0 Lp
D
32.3
36.1
38.5
42.3
44.1
39.9
35.5
29.0
48.4 LpA
Legend
A Sound Power Levels at Unit's Acoustic Center, Lw
B A -Weighted Sound Power Levels at Unit's Acoustic Center, LwA
C Sound Pressure Levels at Specific Distance from Unit, Lp
D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA
Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI
Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed
that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical
estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be
appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate
an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an
Acoustical Engineer or a person with sound prediction expertise should be consulted.
23
18
16
04
02
CO
FanCurve
m 03 C6 CO 12 15
Airf aw(CFM-thousands)
RPM=1164BHP=1.13 MaximumBHM=1175 MaximumBHP=2.40
Note:Pleasecontactapplicationengineeringforselectionsoutsidetheshadedregion.
SC-SystemCucve RP-RatedPoint
18
21
3.008FP
2
24
Packaged Rooftop Builder 1.39g Page 9 of 10
Unit Feature Sheet for 4 Ton
Project:-Untitled2
Prepared By:
03/18/2014
04:57PM
WeatherMaker' — 48TC
PACKAGED ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS
3,4.5,6,7.5.8.5„10,123,15TON S
Optional Louvered Hail Guard SholAn
FSNRAE
compusim
O i
WEATHERMAKER SERIES
Weatherfvlaker(413TC)units are one-piece gas heating. electric
cooling units that are pre -wired and charged with Puron
(R-410) refrigerant. They are factory tested in both heating
and cooling modes, and rated in accordance with AHRI
Standards 210/240(04-06 sizes) and 340/360 (07-16 sizes).
WeatherMaker units are designed in accordance with UL
Standard 1995, and listed by the Underwriters' Laboratories.
Approvedand certified by:
: ACM
CERTIFIED,
US
Certified to ISO 9001
STANDARD FEATURES INCLUDE:
• Filial" (F:-4100A.)HFC refrigerant
• ASH AE33.1 energ y co mode nt
• Scroll compressors avith interns1Fne breek end overload protection
• Sing !e-staae±oolina cap aoitycontrol on 04.12 models
• Two-stege cooling capacity control on08-16models
• SEERS up to 13.3, EER's up to 11.1 end IEER'5upto 11.8
• Acutroi"erefrgerentmelering system
• Exrlusi,a non-corrosir'e composite condensate pan in a000rdanoewith
ASHRkE Standard 52, sloping design, side or oenter drain
• Standard cooling operation up to115`F(45'C)anddown to40`F(4'C)
- down -to 25' F (-4` C) with hinter start kit.
• Pre -painted exteriorpanels and primer -coated interior panels tested to
5133 hour salt spray protection
• Fury insulated ea b in et
• Exclusive IGC solid-state control for on -board diagnostics with LED
error code designation burner control logic and energy saving indoor
fan rratordelsy
• Low N'Jx models thatmeetCel fom,s Air Quality Management
• Induced draft gasheat combustiondesign
• Redundantgasrreh'es.vthuptotwo stages ofheating
• Low pressure and high pressure savtch protected.
MAINTENANCE FEATURES:
• Aooesspaneiswth easygrio handles
• Innovative easystarting, no -strip screws on unit ecoess panels
• Two-inch disposable retum air fitters and T+ookess fitter access door
• Bet drive. evaporator -fan motor and pulleyoonrbinations
• flew Lerminalboard faoltstin•g simple safety circuit troubleshooting and
s npi€tedornt'olboxarrangement
• Exclusive IGC solid-state control for on -board d is gnostics with LED
error code desig natio n, bLIT ercontrol logic end energy saving indoor
fan motor delay.
INSTALLATION FEATURE S:
• Thru-the-bottom power entry capability
• Sine paintgasand electric connections
• Fug perimeter beeeradwith bud -in rigging adapters. and fork slots
• Field convertttefrom vertical to hprizonteleirflow for slab mounting.
(16 site models require field instated supplyduotcover)).
STANDARD WARRANTY:
• 13-yearheatexchanger— 15•yearstainless steel option
• 5-year compressor
• 1-ye.arparts
• 3-yesr °arts on NovetionCondensercoits —where evadable
• Many optional upgrades also evadable
OPTIONS INCLUDE BUTARE NOT LIMITED TO:
• Prsm?erLink-• end RTU Open Muti Protocol DDC Controls
• Supply and Return Air Smoke Detectors, high static motors
• Louvered condensercolguerds
• Econom2er,disconnect end convenience outlet options
• StaintessSteel hest excheage roption
• Corrosion resistant coil costing.
• 1-tumidi-LiZer2 edeotivedehumidification system evadable on et
modelswith RTPF condenser cods — Motor Master I controller included
• Hinged access panels
Fora complete let of options and accessories refer to the Product Data
Catalog forthis unit.
Packaged Rooftop Builder 1.39g Page 10 of 10
r.rom' 03/19/2014 11:14 #252 P.002/004
Attn:
Ammtrommwers
DIMENSIONED AND TOLERENDED PER ANSI VIASM-1Ed2
21 1/2'
YORK
DCG 036/072; DJ 036/048/060
1RC0434
— 45 1/2"
26"
21 1/2" —
Existing Roof Curb
rt— 2' TYP.
Tag:
RETURN
AIR
SUPPLY
AIR
7-
1 3/4" TYP.
37 1 /4"
73"
WOM.FCKY VW MOO
N i.]LLVNG: : MCMMMEN
inn)
APPROVALS
* Verify existing curb OD
* Verify supply and return openings
* Note any changes
*Cali with any questions
y * Fax back if drawing is OK as is
DATE
mgreenwnod
CYFcxER
10/10/2011
03
02
01
UPDATED BRACES
UPDATED ADDRESS
INITIAL DESIGN
10/5/11
7/5/06
11/8/01
VFW G
AL
MWG
REV.
DESCRIPTION
DATE
APPROVED
so if
7560 TYLER ST NW
ELK RIVER, UN 55330
763)391 779e
_ L763)3917851
YORK
ROOF CURB
!ICE NAME OMMHG NO.: REV. 03
5005 5005
ECOK
scAL ,1:16
sHE[T.1 OF 1
OPT/ONS:
MATERIAL; ego. GAL STEEL
INSULATED PANELS (WHERE REQUIRED)
-1121,13 DUCT INSULATION (Et VALUE 3.85) I
GASKET PROV/DED WITH CURB
1 1/2" ADDED TO EXISTING CURB O.O.
22 1/E,
25 101'
-1 $E 3/4"
2` TY P
V'
INSULATED
---___
18 518"
— 39 1,5/16"
70 715'
DAllie I
tel 1.(01
t so
Attn: Tag:
Approval:
New Curb Adapter
EXISTING CURB LAYOUT
45 1/2"
F...._ 26" --$.-
21 1/2'
2 114" —$.11-*-- 2 114"
•
211112"
T-7
RETURN
' I
75-
T
. •_ 74 1/2'
5..
CURB SHOWN IS CDt STANDARD CONFIGURATION CDI RESERVES THE RIGHT TO
CHANGE LAYOUT WITHOUT NOTIFICATION. IF CURB IS NEEDED IN A DIFFERENT
CONFIGURATION CDI MUST :BE NOTIFIED PRIOR TO PLACING AN ORDER.
SUPPLY
37 1/4"
REV,
2
OE3CRtTI0 1 DATE
INMAI DWG
UPDAISO IOP RACE SPE. 6/29/7036
1I/39/1t
APPROVED
cKF
00
New Curb Adapter
OPPEIVAI,E
slasher
2/zarzo$4
OCITET013--
ME( .5 IMPLY AND RETURN OPFSANCs
NOTE ANY CHANGES
CALL MTN ANY QUESTIONS
FAAM1GI6OK ALIA
landsp. Apri 22. 2613 100
Q2AV
1-5005-4000
QUOTE #:
vaolasa
171166 TYLEA ST AW
CDIELA R.IVER.SIN $1310
(7511/114110
V1913114841
71.11
1.5005-4000
.1.75 wwavv. e, 3
tOnibn0',1 7WO
RATINGS
CAPACITY RATING - Coolino / Hectic Heatin
MODEL
ARI RATINGS
NOMINAL
ELECTRIC HEAT CAPACITY3
(KW)
COOLING CAPACITY
80 / 67-95°F
SOUND
RATING2
MBH
SEER
EER
240V
480V
00V
10,
15&20
DCE036
40
10.10
9.30
_(12e121_,..e
8.6
5 7, 10,
15&20
7, 10,
15&20
DCE048
48
10.35
9.45
8.6
5 7, 10,
15&20
7, 10,
15&20
10,
15.&20
DCEO60
59
10.15
9:40
8.6
5, 7, 10,
15,20&30
7, 10, 15
20&30
10, 15,
20&30
DCE072
72
,., ,.., •_
-
_„�,_
9.00
�.
8.4
5, 7, 10,
15,. 20 & 30
7, 10, 15,
20 & 30
10, 15,
20 & 304_
CAPACITY RATINGS - Cooling / Gas Heating
530.18-TG1Y
WEIGHT (WT) calc, LBS
BASE UNIT WT 645
ECONOMIZER 50
EXSTG ROOF CURB.. 125
TOTAL WT 820
ARI RATINGS
GAS HEAT CAPACITY
MODEL
COOLING CAPACITY
SOUND
INPUT
OUTPUT
AFUE
S.S.E.
S.E.
TEMP.
GAS
80 / 67-95°F
RATING2
RISE
LINE SIZE
S ER
EER
_ ...*_MBHI
�. (bels
(MBH)
(MBH)
(%)
(%)
(%)
°
DCG036N.040
40
10.10
9.30
8.6
50
40
80.91.031.
81.6
75.9
15-45
1/2
DCG036N079
40
10.10
9.30
8.6
100
79
80.5
80.8
73.6
40-70
1/2
DCG048N060
48
10.35
9.45
8.6
75
60
80.9
81.6
77.3
25-55
1/2
DCG048N099
48
10.35
9.45.
8.6
125
99
80.3
80.6
77.9
45-75
1/2
0CG060N079
59
10.15
9.40
8.6
100
79
80.5
80.8
73.6
25-55
1/2
DCGO6ON099
i .59
10.15
. 9.40:
8.6
125
99
80.3
80.6
77.9
35-65
1/2
DCG072N079
72
-
9.00
8.4
100
79
80.5
80.8
73.6
25-55
1/2
.,i sgQ72N099 _
72
-m,,_, ,
2,00
8 4
125
_ 99
80.3
89.6
77.9.
35-65
1/2
Ratings are in accordance with ARI Standard 210. Sound ratings are in accordance with ARI Standard 270. 3Heaters are available as accessories - all with single point power arppty.
SEER = Seasonal Energy Efficiency Ratio - the tote' aod'r: g output In BTU's during a normal annual usage period for cooing divided by the total •metric powerkpd In wefawcas doing the same period
EER = Energy Efficiency Ratio - the cooling capacity in Stu's per hour (81uh) divided by the power input In watts at any given set of rating condtons, expressed In BTUH per watt (STUHrwat).
AFUE = Annual Fuel Utilization Efficiency - determined in accordance with DOE test procedure.
S.S.E. = Steady State EtFdenry. (Percent Output).
S.E. = Caifomia Seasonal Efficiency - determined in accordance with test procedures as specified by the Stale a QaEbnt a Energy Commission. Furnaces are ava table with aim NOx sooessory.
= Not ARI Usted.
SICAL DATA - BASIC U
MODELS
,...,.-� .-
DCE/DCG
1 ..
Ofi0
n7
EVAPORATOR
BLOWER
CENTRIFUGAL BLOWER (Dia. x Wd. in.)
FAN MOTOR HP DIRECT -DRIVE)
FAN MOTOR HP (M.T DRIVE)
12 x 10
1/2
1
..,, - -
12 x 10
3/4
1.5
12 x 10
1
1.5
12 x 11
1
1.5
EVAPORATOR
COIL
ROWS DEEP
FINS PER INCH
FACE AREA(So.Ft.)
3
13
3.6
3
13
4.3
3
13
5.1
4
13
5.1
CONDENSER
PROPELLER DIA. (in.)
FAN MOTOR HP
NOM. CFM TOTAL.
22
1/2
4.500
22
1/2
4.200
22
1/2
4.500
1
22
17 1
24
1/2
4.500
2
16
16 7
CONDENSER
COIL
ROWS DEEP
FINS PER INCH
FACE AREA (Sa. Ft.)
1
16
17.1
1
19
17.1
AIR
FILTERS
(SEE NOTE)
QUANTITY PER UNIT (14" X 20" X 1")
QUANTITY PER UNIT (14" X 25" X 1")
TOTAL FACE AREA (sq. ft.)
2
1
6.3
2
1
6.3
2
1
6.3
2
1
6.3
CHARGE .
R, , FRI aFRANT 99 fih.S.(.
. s
6/B
.714
1013
NOTE: Filter racks are adapted for 1' or 2' thick filters.
COMPONENT WEIGHTS
COMPONENT
Basic Unit
Options
and
Accessories
DCE (Cooling only)
•
DCG (Gas / Electric)
Economizer
Motorized Outdoor Air D
Electric Heat
(Nominal KW)
(DCE only)
Roof Mounting Curb
Relief / Fixed Air Damper
Belt -Drive Blower
NOTE: Weights are given in pounds.
1
MODELS CE & DCG
IO.t --Alai- _,.9 _5za ... -..LIM.
545 585 610 670
40 Mbh 605 - -
60 Mbh
79 Mbh 615
99 Mbh
mper
5-7KW
10 - 15 KW
20-30KW
655
670
680
50
48
18
2.3
28
92
10
5
725
735
Unitary Products Group
3
Existing
ROOF CURB DIMENSIONS • (DCE and DCG - 3, 4, 5 & 6 TON)
DUCT SUPPORT RAILS 2 TYP,
BACK
OF UNIT
SUPPLY°
AIR
RE7URN°
AIR
37=1/4"
DUCT SIZES:
Supply Air r 19-1/4" X 19-1/4"
Return At r 18•i/4" X 19.1/4"
ROOF CURB BENEFITS
"
COMPRESSOR
AND CONDENSER
END OF UNIT
FRONT
OF UNIT
530.18-TG 1 Y
Supply and Return Alr (Including duct support raft)
shown era typical for Dom duct applications.
Far location or hatI7401,111 duct applications
(on back of unit), refer to Unk Dimension detach,
FRONT VIEW (3-JOIST SUPPORT)
NOTE: Both supply air and Mum air duct openkgs am aquas and am the same alga, pro-
vidng easy duct Inetaliatlon. Duda can be installed onto the curb from the roof. All electrical
w(rinQ connections can be made Inside the curb.
UNIT AND CURB APPLICATION
FRONT VIEW (2-JOIST SUPPORT)
4'
72' LALTERNATEI
The 431E ovoid dad dmanabn slows ductwork penemsdion
between roof Joists that are wooed on 46' cotters.
3/4" X 1-1/4" WIDE GASKETING FOR CURB
FRAME AND ALL DUCT SUPPORT SURFACES
UNIT BASE
W000 NAILER UNIT BASE RAILS
14"
8" MIN. ABOVE FINISHED ROOF — 1 COUNTERFLASHING
CURB FRAME— CANT STRIP
INSULATION AND ROOFING MATERIAL
INSULATION
ROOF DECK AND SUPPORT STRUCTURE
Unitary Products Group
19
BTL
l:\(;1\i BRING
FILE COPY
19011 Woodinville Snohomish Rd NE, Suite 100
Woodinville, WA 98072-4315
Phone: (425) 814-8448
Fax: (425) 821-2120
Structural Calculations
for
Bay Valve AC 1 Mech'l Unit
Support of Proposed HVAC Unit
March 28, 2014
REVIEWED FOR
,ODE COMPLIANCE
APPROVED
APR 2 2 2014
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
APR 1 6 2014
HP116T14
BTL
i.NGINEERING
`;-
ewv, 0,1
A '1/41.4#14.1e' 4,4.4.i
17924 — 140th Avenue NE, Suite 220
Woodinville, WA 98072-4315
Phone: (425) 814-8448
Fax: (425) 821-2120
Calculations
•
BTL
17924 — 140th Avenue NE, Suite 220
Woodinville, WA 98072-4315
Phone: (425) 814-8448
Fax: (425) 821-2120
Gravity Support
63/4X36 (TYP)
j
tic
a
A
4X16ROUGH D.F. #1
OUTLINE AC-1
OUTUNENL
CURB ADAP
STINCROOF CUR
A'
4X16ROUGH D.F. #1
iP
63/4X36 (TYP)
1 4 X 16 ROUGH D.F. 11
J
,PARTIAL ROOF EQUIPMENT & FRAMING PLAN
//8n=,}On
. . .
ENGINEERING
19011 Wood-Sno Road NE, Suite 100
Woodinville, WA 98072-4436
Phone: 425-814-8448
Fax: 425-821-2120
D
M = Co, 70 X-rt
6
/11
7/ 1
A
r(0fl
7c--'
iy*--0(3-06/,/.5"(k)6/,;,)
'f\x/4, DE HI
3 .Bict
-000. .
74/20*
0, 73 ic.-/-7:-/
ro /Cc-) F57
/•
r-7/
" /./S _ e/C'
/14fi /14
Project: Designed By: Date.
Scale. Pae. 6- —
z
Project Number:
Client:
BTL
1 NG1 NEFR1
17924 — 140th Avenue NE, Suite 220
Woodinville, WA 98072-4315
Phone: (425) 814-8448
Fax: (425) 821-2120
Seismic Support
Bay Valve AC 1 Mech'I Unit Revision Date: 3/28/2014
Occupancy Category: ii - other Structures
Seismic Use Group: I
/E = 1.00 (Seismic Factor)
Is = 1.00 (Snow Factor)
/w = 1.00 (Wind Factor)
Site Class:
Ss = 1.5 `!
51=0.5``'.
D
Fa = 1.00
F = 1.50
v IBC Table 1604.5
v I ASCE Table 20.3-1
ASCE Table 11.4-1
ASCE Table 11.4-2
Design Spectral Response Acceleration:
SMs = FaSs
= 1.50
SDS=Z/3 SMS
= 1.00
SM1 = FvS1
= 0.75
SD1 = % SM1
= 0.50
Bay Valve AC 1 Mech'I Unit Revision Date: 3/28/2014
0
Seismic Forces
Component Operating Weight: 889 Ibs
Fp = 0.4 ap SDs Wp
Rp / Ip
Fp = 427 Ibs
Fp need not exceed:
Fp = 1.6 SDS Ip Wp
Fp = 1422 Ibs
Fp shall not be less than:
Fp = 0.3 SDS Ip Wp
Fp = 267 Ibs
Dimensions:
x = .46.75 , in
y = 74.375 , in
z= 17. in
Curb Height = 28 in
Check Uplift:
MOT = 15575 lb -in
MRESIST = 18702 lb -in
UPLIFT = 333 lb
[1+2 (zlh)] ASCE Eq. 13.3-1
ASCE Eq. 13.3-2
ASCE Eq. 13.3-3
x y
z
Curb Height
F.S. = 1.2 5 1.5
NOT O.K.
Will Be Resolved By Attachment.
See Page 5 _ 3-
5- Z
• Br
—4
ENGINEERING
19011 Wood-Sno Road NE, Suite 100
Woodinvile, WA 98072-4436
Phone: 425-814-8448
Fax: 425-821-2120
r
iet 11C4eop- 4. •C
ilk '4' /lea
/Vino Ce•friv
u 56 IF G/1-ri Srcs.1._ fm.4103- LJ/(2)zittia
"cc
sciur-do = /4j 5747-4ER (2)W
577Z4P5 goeie(v 5/o/E- 0/
5-2644
PtJe
Gip‘ipr
MJ Curio
,ce-o.ctus
37e.
.73
Ceveb
26 5#1°t-o- 5-co-etc)
(2) cer-ew
/-14/0 (0)
ect,,5 Aecie4 Side
Project:
Project Number Client:
Designed By:
Scale:
Date.
$ -.3
Page.
BTL
I'\(;1\1'I RI\(
17924 — 140th Avenue NE, Suite 220
Woodinville, WA 98072-4315
Phone: (425) 814-8448
Fax: (425) 821-2120
Details
FA57ENAC-1 TONEW CURBADAPTER WITH 18-G4
S EEZ STRAP; (2) #10SlREWS T11RUS7RAPINTO
AC-184SERA!L, (2) #10SLREWS'TNRUSTRAP
INTONEW CIRI3 NWT& (2) S7RAPS EACH
CORNERR (8) S7RAPS TOTAL (4) SCREWS EAQf
S7R4P, (32)SCREYYSTOTAL
NEW WRIT AD4PTER
FASTEN NEW CURB ADAPTER TO &17577NG
ROOF CURB WITH #10SCREWS; (2)
SOWS MCISIDE (2) SCREWS EAOf
END. (8) TOTAL SCREWS.
EXISTINGROOF CURB
SIDE VIE W A -A' END VIE W B -B'
AC-1 ATTACHMENT DETAIL
NOT TO SCALE
City of Tukwila
Department of Community Development
10/1/2014
Jim Haggerton, Mayor
Jack Pace, Director
MARK SMELTZER
112 CENTRAL AVE S
KENT, WA 98032
RE: Permit No. M14-0084
BAY VALVE SERVICE, INC.
4385 S 133 ST
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric
Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null
and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if
the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 11/9/2014.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each
inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire.
Address your extension request to the Building Official and state your reason(s) for the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 11/9/2014, your permit will become null and void
and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Bill Rambo
Permit Technician
File No: M14-0084
6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M14-0084
DATE: 04/16/2014
PROJECT NAME: BAY VALVE SERVICE INC
SITE ADDRESS: 4385 S 133 ST
X Original Plan Submittal
Response to Correction Letter #
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
/4-3- ,WC ` 19'1 vi
Building Division M
Public Works
n
MA i/A- y•
Fire Prevention
Structural
Planning Division
Permit Coordinator
PRELIMINARY REVIEW:
Not Applicable n
(no approval/review required)
DATE: 04/17/14
Structural Review Required
REVIEWER'S INITIALS: DATE:
n
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
(corrections entered in Reviews)
Approved with Conditions
Denied
(ie: Zoning Issues)
DUE DATE: 05/15/14
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
PERFORMANCE HEATING & A/C TNC
Page 1 of 2
Washington State:Department of
Labor & Industries
PERFORMANCE HEATING & A/C INC
Owner or tradesperson
MILLER, DANIEL E
Principals
MILLER, DANIEL E, PRESIDENT
ERDAHL, DARRIN, VICE PRESIDENT
GOWIN, RICHARD L, VICE PRESIDENT
(End: 04/26/2011)
GOWIN, CONSTANCE F, VICE PRESIDENT
(End: 11/15/2007)
Doing business as
PERFORMANCE HEATING & A/C INC
WA UBI No.
600 601 386
1012 Central Ave S
KENT, WA98032
425-251-0356
KING County
Business type
Corporation
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor
License specialties
GENERAL
License no.
PERFOHA15ORT
Effective — expiration
12/30/1985— 04/30/2015
Bond
DEVELOPERS SURETY & INDEM CO
Bond account no.
748802C
Received by L&I
11/27/2007
Insurance
American Fire & Casualty Co
Policy no.
BKA56064545
Received by L&I
04/21/2014
Active.
Meets current requirements.
$12,000.00
Effective date
10/01/2007
$1,000,000.00
Effective date
04/28/2014
Expiration date
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600601386&LIC=PERFOHA150RT&SAW= 05/13/2014