Loading...
HomeMy WebLinkAboutPermit M14-0084 - BAY VALVE SERVICE - ROOFTOP COOLING/GAS HEAT UNITBAY VALVE SERVICE INC 4385 S 133 ST EXPIRED 11/09/2014 M14-0084 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 2613200130 4385 S 133 ST Project Name: BAY VALVE SERVICE, INC. MECHANICAL PERMIT Permit Number: Issue Date: Permit Expires On: M14-0084 5/13/2014 11/9/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: SEBCO INC 4020 E MADISON ST #320 , SEATTLE, WA, 98112 MARK SMELTZER 112 CENTRAL AVE S , KENT, WA, 98032 PERFORMANCE HEATING & A/C INC 7649 S 180 ST, KENT, WA, 98032 PERFOHA150RT III Phone: (425) 251-0356 Phone: (425) 251-0356 Expiration Date: 4/30/2015 DESCRIPTION OF WORK: REPLACE FAILING 4-TON ROOFTOP PACKAGE COOLING/GAS HEAT UNIT WITH LIKE FOR LIKE UNIT IN THE SAME LOCATION. CONNECT NEW UNIT TO EXISTING DUCTS, POWER SUPPLY, AND OTHER UTILITIES. Valuation of Work: $8,000.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $298.16 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer Distric: TUKWILA SEWER SERVICE,VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: Permit Center Authorized Signature: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Date: :1EI'-13-" I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: GIL (2V'iE Date: SA3/020/V This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 3: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 4: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: ***MECHANICAL PERMIT CONDITIONS*** 8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKW_ _ Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wvvw.TukwilaWA.gov Mechanical Permit No. Mlq-06111 Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: Tenant Name: 4385 S 133rd St, Tukwila, WA 98168 BAY VALVE SERVICE, INC PROPERTY OWNER Name: SEBCO INC Address: 4385 S 133RD St City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Mark Smeltzer Address: 1012 Central Ave S City: Kent State: WA Zip: 98032 Phone: (425) 251-0356 Fax: (253) 867-5775 Email: mark@pmghvac.com King Co Assessor's Tax No.: 261320-0133 Suite Number: Floor: 1 New Tenant: ❑ Yes ❑✓ ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Performance Mechanical Group Address: 1012 Central Ave S City: Kent State: WA Zip: 98032 Phone: (425) 251-0356 Fax: (253) 867-5775 Contr Reg No.: PERFOHA15ORT Exp Date: 04/30/2015 Tukwila Business License No.: BUS-0994165 Valuation of project (contractor's bid price): $ 8,000 Describe the scope of work in detail: Replace failing 4 ton Rooftop Package Cooling/Gas Heat Unit with like -for -like unit in the same location. Connect new unit to existing ducts, power supply and other utilities. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas ! Other: H:\Applications\Forms-Applications On Line\201 1 Applications\Mechanical Permit Application Revised 8-9-1 l.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >l 00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm 1 Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED 4G Signature: Print Name: Mark Smeltzer Mailing Address: 1012 Central Ave S Date: 04/15/2014 Day Telephone: (425) 251-0356 Kent WA 98032 City State Zip H:'Applications\Forms-Applications On Line12011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY I PAID $24082 M14-0084 Address: 4385 S 133 ST Apn: 2613200130 $240.82 MECHANICAL $229.35 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $196.85 TECHNOLOGY FEE $11.47 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2111 R000.322.900.04.00 $11.47 $240.82 Date Paid: Tuesday, May 13, 2014 Paid By: GIL ROMERO PERF MECH GROUP Pay Method: CREDIT CARD 844183 Printed: Tuesday, May 13, 2014 1:09 PM 1 of 1 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY I PAID $57.34 M14-0084 Address: 4385 S 133 ST Apn: 2613200130 $57.34 MECHANICAL $57.34 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R1821 R000.322.102.00.00 $57.34 $57.34 Date Paid: Wednesday, April 16, 2014 Paid By: PERF. MECH. GROUP Pay Method: CREDIT CARD 736812 Printed: Wednesday, April 16, 2014 9:42 AM 1 of 1 SYSTEMS FILE COPY CCarrie� United Technologies SUBMITTAL Project -Untitled2 Date Tuesday, March 18, 2014 REVIEWED FOR CODE COMPLIANCE APPROVED APR 2 2 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKkikii�h APR 1 6 2014 PERMIT CENTER M I'4OO1 Table Of Contents Project:-Untitled2 Prepared By: rg" 01111, 03/18/2014 04:57PM 4 Ton 3 Unit Report Certified Drawing 5 Performance Summary 7 Unit Feature Sheet 10 ,jj, :if) M1;'r " - 4 Packaged Rooftop Builder* 1.39 Page 2 of 10 4 Ton Project:-Untitled2 Prepared By: 03/18/2014 04:57PM 4 Ton Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Packaged Rooftop Builder 1.39g Page 3 of 10 Unit Report For 4 Ton Project:-Untitled2 Prepared By: 03/18/2014 04:57PM Unit Parameters Unit Model. 48TCDA05A2A6-0A0A0 Unit Size. 05 (4 Tons) Volts -Phase -Hertz. 460-3-60 Heating Type• Gas Duct Cfg- Vertical Supply / Vertical Return Low Heat Round Tube Plate Fin Coils Lines and Filters Gas Line Size. 1/2 Condensate Drain Line Size- 3/4 Return Air Filter Type- Throwaway Return Air Filter Quantity. 2 Return Air Filter Size- 16 x 25 x 2 Unit Configuration Medium Static Option AI/Cu - AI/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger - Aluminized(std.) No optional warranties were selected. Dimensions (ft. in.) & Weight (Ib.) *** Unit Length- 6' 2.375" Unit Width. 3' 8" Unit Height. 2' 9.375" *** Total Operating Weight 597 Ib *** Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48TCDA05A2A6-0A0A0 Rooftop Unit 1 Base Unit Electromechanical control, No intake or exhaust option None Accessories CRECOMZR020A02 Vertical EconoMi$er IV with solid-state controller 1 Packaged Rooftop Builder 1.39g Page 4 of 10 Certified Drawing for 4 Ton Project: "-Untitled2 Prepared By: 03/18/2014 04:57PM NOTES: 1. DIMENSIONS ARE IN INCHES DIMENSIONS IN [ ] ARE IN MILLIMETERS. 2. CENTER OF GRAVITY 3. apor, DIRECTION OF AIR FLOW UNIT 48TC-A04 (48TC-A05 48TC-A06 33 3/8 [8471 33 3/6 [847] 18 5/8 [4121 14 1/8 [3711 33 3/8 [8471 147/8 [3711 48TC-A07 41 3/8 [1051] 14 7/8 [3711 FILTER ACCESS PANEL (TOOL -LESS) • COND. ACCESS • PANEL ' C= CONDENSER COIL INDOOR COIL ACCESS PANEL ' 3-3/4 J [95] BACK CONDENSER COIL OPTIONAL FACTORY INSTALLED CONVENIENCE OUTLET 46 3/4 [11871 LEFT 44 2-5/8 — [67] TYP CURB WIDTH 4-5/8 [1181 LECTRICAL DISCONNECT LOCATION 19 1/2 6-5/8 [168] 32 1/4 [8181 4, 18-1/8 I [4591 1 t 16-1/8 1/-1/4 12-1/4 I [/11] [383] [312] N SEE THRU THEJ UASE"CHART s_ 33 3/8 [8481 C UNITED P.O. BOX 4608 TECHNOLOGIES SYIAONSE, n CARRIER TS UI THIS DOCUMENT IS THE PROPERTY 00 CARRIER CORPORATION AID IS DELIVERED WON THE EXPRESS CONDITION THAT THE CONTENTS WILE NOT RE DISCLOSED 01 USED NITXONI CARRIER CORPORATION'S WRITTEN COGENT. SWNIESEON W THESE DRAWINGS OR DOCUMENTS DOES NOT CONSTITUTE PART PERFORMANCE OR ACCEPTANCE OF CONTRACT. ECONOMIZER HOOD (OPTIONAL) 25-5/8 [652] RETURN AIR 0 E ALT. CONDENSATE DRAIN OPENING IN DASEPAN 17-3/4 [4511 SUPPLY AIR • �6-1/4 � 1571 • 16 [406] 10-7/8 [2771 26-1/2 [6 3] RETURN AIR 28.3/8 111011. [7471 SUPPLY AIR OPTIONAL FACTORY INSTALLED DISCONNECT 25 [636] 4 [100] LUE HOOD TOP 3-3/8 12-1/8 [851 [3071 �-- 10-1/2 -ww [4101 CONTROL 80X INDOOR BLOWER ACCESS PANEL ACCESS HANDLE 118881 FRONT ANDLE CONNECTION SIZES A 1 3/8' [351 DIA FIELD POWER SUPPLY HOLE 8 2' [501 DIA POWER SUPPLY KNOCKOUT C 1 3/4' [511 DIA GAUGE ACCESS PLUG 0 7/8' [221 DIA FIELD CONTROL WIRING HOLE 6 3/4'-14 NPT CONDENSATE DRAIN F 1/2'-11 NPT GAS CONNECTION G __2 1/2 ' 1641 DIA POWER SUPPLY KNOCK -OUT THRU-THE-RA E CHART THESE HOLES REQUIRED FOR USE CRBTMPWR00IA01, 003A01 THREADED WIRE REO'D HOLE CONDUIT SIZE USE SIZES (MAX.) 1/2' ACC. 7/8' [22.21 X 1/2' 244 7/8" [22.21 Y I 3/4' 1001,003) POWER 1 1/8' [28.4] ZNN (0031 1/2' FPT GAS 1 3/16' [30.01 FOR 'THRU-THE-BASEPAN' FACTORY OPTION, FITTINGS FOR ONLY I.Y, 8 Z ARE PROVIDED SELECT EITHER 3/4' OR 1/2' N FOR POWER, DEPENDING ON WIRE SIZE WP (001) PROVIDES 3/4" FPT THRU CURB FLANGE N FITTING. [2651 (-1/4 1- 1321 E STD. — CONDENSATE DRAIN } 11-3/8 [289] 6.1/8 11551 1— [1681 [1711 26 3/4 — [681] 31 1/4 [793] 18.3/4 ww 14271 11 SUPPLY AIR (gyp) JI�Y 25-I/8 [6381 RETURN AIR 6 [152] SUPPLY AIR RETURN RIGHT ILTER IOUTSIDE AIR //4 21-1 15391 11 Jr BAROMETRIC RELIEF FLOW SHEET 1 OF 2 DATE 11-24-08 SUIERCEDES 09-29-08 48TC 04-07 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48TM500993 1Er 5.0 Packaged Rooftop Builder 1.39g Page 5 of 10 Certified Drawing for 4 Ton Project:-Untitled2 Prepared By: 03/18/2014 04:57PM AC-1 UNIT STD. UNIT WEIGHT CORNER WEIGHT (A) CORNER WEIGHT (B) CORNER WEIGHT (C) CORNER WEIGHT (D) C G. HEIGHT LBS. KG. LBS. KG. LBS. KG. LBS. KG. LBS. KG. K Y Z 487C-804 483 219 111 50 125 57 131 59 116 53 39 19911 23 15841 16 3/8 [416] (487C-805 537 244 124 56 139 63 145 66 129 59 39 19911 23 [5841 17 [4321 1 481C-806 569 258 131 59 147 67 154 70 131 62 39 (9911 23 [5841 17 1/4 (4381 481C-A01 652 296 150 68 169 76 176 80 157 71 39 19911 23 [5841 20 1/8 15111 0 UNITED P.O. 80A A606 TECHNOLOGIES MERCURE, RI CARRIER 13221 IRIS HOOKER! IS TOE PROPERTY 00 CARRIER CORPORATION AND IS OELIYEIED UPON THE ESPRESS CONDITION THAT THE CONTENTS WILL ROT DE DISCLOSED OR USED WITHOUT CARRIER CORPORATION'S WRITTEN CONSENT. SU6MIS6I01 OF THESE DRAWINGS OR DOCUMENTS DOES R01 C015TITUTE PART PERFORMANCE 02 ACCEPTANCE OF COITRACT. CORNER A CORNER 8 TOP A• uuIui ! CORNER C D..M I I O : 00• FRONT WEIGHT (WT) calc, LBS BASE UNIT WT 537 ECONOMIZER 50 CURB ADAPTER 167 EXSTG ROOF CURB.. 125 MISC 10 TOTAL WT 889. SHEET 2 OF 2 DATE 11-24-08 SUMMER 09-29-08 48TC 04-07 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48TM500993 REY 5.0 Packaged Rooftop Builder 1.39g Page 6 of 10 Performance Summary For 4 Ton Project:—Untitled2 Prepared By: 03/18/2014 04:57PM Part Number:48TCDA05A2A6-0A0AO ARI SEER- 13.00 Base Unit Dimensions Unit Length. 74.4 in Unit Width- 44.0 in Unit Height. 33.4 in Operating Weight Base Unit Weight- 537 Ib Medium Static Option. 10 Ib Accessories Vertical EconoMi$er IV with solid-state controller. 50 Ib Total Operating Weight. 597 Ib Unit Unit Voltage -Phase -Hertz. 460-3-60 Air Discharge. Vertical Fan Drive Type. Belt Actual Airflow. 1600 CFM Site Altitude. 0 ft Cooling Performance Condenser Entering Air DB• 95.0 F Evaporator Entering Air DB. 80.0 F Evaporator Entering Air WB. 67.0 F Entering Air Enthalpy. 31.44 BTU/Ib Evaporator Leaving Air DB. 60.2 F Evaporator Leaving Air WB- 57.7 F Evaporator Leaving Air Enthalpy. 24.83 BTU/Ib / Gross Cooling Capacity. 47.60 MBH Gross Sensible Capacity- 34.22 MBH Compressor Power Input- 3.31 kW Coil Bypass Factor. 0.246 Heating Performance Heating Airflow- 1600 CFM Entering Air Temp• 70.0 F Leaving Air Temp- 104.1 F Gas Input Capacity 72.0 MBH Gas Heating Capacity- 59.00 MBH Temperature Rise. 34.1 F Supply Fan External Static Pressure. 1.00 in wg Options / Accessories Static Pressure Economizer 0.07 in wg Total External Static. 1.07 in wg Fan RPM. 1164 Fan Power 1.13 BHP NOTE Selected IFM RPM Range: 770 -1175 Electrical Data (Before July 30, 2012) Minimum Voltage. 414 Maximum Voltage- 506 Compressor RLA. 6.2 Compressor LRA• 41 Outdoor Fan Motor Qty. 1 Outdoor Fan FLA (ea). 0.8 Packaged Rooftop Builder 1.39g Page 7 of 10 Performance Summary For 4 Ton Project:-Untitled2 Prepared By: 03/18/2014 04:57PM Indoor Fan Motor Type. MED Indoor Fan Motor FLA• 2.1 Combustion Fan Motor FLA (ea). 0.24 Power Supply MCA. 10.7 Power Supply MOCP (Fuse or HACR)• 15 Min. Unit Disconnect FLA. 10 Min. Unit Disconnect LRA• 49 Electrical Convenience Outlet None Electrical Data (July 30, 2012 and Beyond) Indoor Fan Motor FLA• 2.6 Power Supply MCA. 12 Power Supply MOCP. 15 Disconnect Size FLA. 11 Disconnect Size LRA. 52 July 30th and beyond units can be identified by serial number 3112XXXXXXXXX and higher Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 88.1 88.0 90.9 125 Hz 82.7 79.8 84.6 250 Hz 74.7 66.4 79.5 500 Hz 70.4 64.0 77.9 1000 Hz 66.9 63.2 76.5 2000 Hz 61.5 57.2 71.1 4000 Hz 63.2 52.8 66.9 8000 Hz 58.6 45.6 62.5 A -Weighted 74.0 69.4 81.0 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground. 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground- 5.7 ft 4. Height of obstruction. 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction. 0.0 ft v Detailed Acoustics Information Packaged Rooftop Builder 1.39g Page 8 of 10 Performance Summary For 4 Ton Project:-Untitled2 Prepared By: 03/18/2014 04:57PM Octave Band Center Freq. Hz 63 125 250 500 1 k 2k 4k 8k Overall A 90.9 84.6 79.5 77.9 76.5 71.1 66.9 62.5 92.4 Lw B 64.7 68.5 70.9 74.7 76.5 72.3 67.9 61.4 80.8 LwA C 58.5 52.2 47.1 45.5 44.1 38.7 34.5 30.1 60.0 Lp D 32.3 36.1 38.5 42.3 44.1 39.9 35.5 29.0 48.4 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A -Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. 23 18 16 04 02 CO FanCurve m 03 C6 CO 12 15 Airf aw(CFM-thousands) RPM=1164BHP=1.13 MaximumBHM=1175 MaximumBHP=2.40 Note:Pleasecontactapplicationengineeringforselectionsoutsidetheshadedregion. SC-SystemCucve RP-RatedPoint 18 21 3.008FP 2 24 Packaged Rooftop Builder 1.39g Page 9 of 10 Unit Feature Sheet for 4 Ton Project:-Untitled2 Prepared By: 03/18/2014 04:57PM WeatherMaker' — 48TC PACKAGED ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS 3,4.5,6,7.5.8.5„10,123,15TON S Optional Louvered Hail Guard SholAn FSNRAE compusim O i WEATHERMAKER SERIES Weatherfvlaker(413TC)units are one-piece gas heating. electric cooling units that are pre -wired and charged with Puron (R-410) refrigerant. They are factory tested in both heating and cooling modes, and rated in accordance with AHRI Standards 210/240(04-06 sizes) and 340/360 (07-16 sizes). WeatherMaker units are designed in accordance with UL Standard 1995, and listed by the Underwriters' Laboratories. Approvedand certified by: : ACM CERTIFIED, US Certified to ISO 9001 STANDARD FEATURES INCLUDE: • Filial" (F:-4100A.)HFC refrigerant • ASH AE33.1 energ y co mode nt • Scroll compressors avith interns1Fne breek end overload protection • Sing !e-staae±oolina cap aoitycontrol on 04.12 models • Two-stege cooling capacity control on08-16models • SEERS up to 13.3, EER's up to 11.1 end IEER'5upto 11.8 • Acutroi"erefrgerentmelering system • Exrlusi,a non-corrosir'e composite condensate pan in a000rdanoewith ASHRkE Standard 52, sloping design, side or oenter drain • Standard cooling operation up to115`F(45'C)anddown to40`F(4'C) - down -to 25' F (-4` C) with hinter start kit. • Pre -painted exteriorpanels and primer -coated interior panels tested to 5133 hour salt spray protection • Fury insulated ea b in et • Exclusive IGC solid-state control for on -board diagnostics with LED error code designation burner control logic and energy saving indoor fan rratordelsy • Low N'Jx models thatmeetCel fom,s Air Quality Management • Induced draft gasheat combustiondesign • Redundantgasrreh'es.vthuptotwo stages ofheating • Low pressure and high pressure savtch protected. MAINTENANCE FEATURES: • Aooesspaneiswth easygrio handles • Innovative easystarting, no -strip screws on unit ecoess panels • Two-inch disposable retum air fitters and T+ookess fitter access door • Bet drive. evaporator -fan motor and pulleyoonrbinations • flew Lerminalboard faoltstin•g simple safety circuit troubleshooting and s npi€tedornt'olboxarrangement • Exclusive IGC solid-state control for on -board d is gnostics with LED error code desig natio n, bLIT ercontrol logic end energy saving indoor fan motor delay. INSTALLATION FEATURE S: • Thru-the-bottom power entry capability • Sine paintgasand electric connections • Fug perimeter beeeradwith bud -in rigging adapters. and fork slots • Field convertttefrom vertical to hprizonteleirflow for slab mounting. (16 site models require field instated supplyduotcover)). STANDARD WARRANTY: • 13-yearheatexchanger— 15•yearstainless steel option • 5-year compressor • 1-ye.arparts • 3-yesr °arts on NovetionCondensercoits —where evadable • Many optional upgrades also evadable OPTIONS INCLUDE BUTARE NOT LIMITED TO: • Prsm?erLink-• end RTU Open Muti Protocol DDC Controls • Supply and Return Air Smoke Detectors, high static motors • Louvered condensercolguerds • Econom2er,disconnect end convenience outlet options • StaintessSteel hest excheage roption • Corrosion resistant coil costing. • 1-tumidi-LiZer2 edeotivedehumidification system evadable on et modelswith RTPF condenser cods — Motor Master I controller included • Hinged access panels Fora complete let of options and accessories refer to the Product Data Catalog forthis unit. Packaged Rooftop Builder 1.39g Page 10 of 10 r.rom' 03/19/2014 11:14 #252 P.002/004 Attn: Ammtrommwers DIMENSIONED AND TOLERENDED PER ANSI VIASM-1Ed2 21 1/2' YORK DCG 036/072; DJ 036/048/060 1RC0434 — 45 1/2" 26" 21 1/2" — Existing Roof Curb rt— 2' TYP. Tag: RETURN AIR SUPPLY AIR 7- 1 3/4" TYP. 37 1 /4" 73" WOM.FCKY VW MOO N i.]LLVNG: : MCMMMEN inn) APPROVALS * Verify existing curb OD * Verify supply and return openings * Note any changes *Cali with any questions y * Fax back if drawing is OK as is DATE mgreenwnod CYFcxER 10/10/2011 03 02 01 UPDATED BRACES UPDATED ADDRESS INITIAL DESIGN 10/5/11 7/5/06 11/8/01 VFW G AL MWG REV. DESCRIPTION DATE APPROVED so if 7560 TYLER ST NW ELK RIVER, UN 55330 763)391 779e _ L763)3917851 YORK ROOF CURB !ICE NAME OMMHG NO.: REV. 03 5005 5005 ECOK scAL ,1:16 sHE[T.1 OF 1 OPT/ONS: MATERIAL; ego. GAL STEEL INSULATED PANELS (WHERE REQUIRED) -1121,13 DUCT INSULATION (Et VALUE 3.85) I GASKET PROV/DED WITH CURB 1 1/2" ADDED TO EXISTING CURB O.O. 22 1/E, 25 101' -1 $E 3/4" 2` TY P V' INSULATED ---___ 18 518" — 39 1,5/16" 70 715' DAllie I tel 1.(01 t so Attn: Tag: Approval: New Curb Adapter EXISTING CURB LAYOUT 45 1/2" F...._ 26" --$.- 21 1/2' 2 114" —$.11-*-- 2 114" • 211112" T-7 RETURN ' I 75- T . •_ 74 1/2' 5.. CURB SHOWN IS CDt STANDARD CONFIGURATION CDI RESERVES THE RIGHT TO CHANGE LAYOUT WITHOUT NOTIFICATION. IF CURB IS NEEDED IN A DIFFERENT CONFIGURATION CDI MUST :BE NOTIFIED PRIOR TO PLACING AN ORDER. SUPPLY 37 1/4" REV, 2 OE3CRtTI0 1 DATE INMAI DWG UPDAISO IOP RACE SPE. 6/29/7036 1I/39/1t APPROVED cKF 00 New Curb Adapter OPPEIVAI,E slasher 2/zarzo$4 OCITET013-- ME( .5 IMPLY AND RETURN OPFSANCs NOTE ANY CHANGES CALL MTN ANY QUESTIONS FAAM1GI6OK ALIA landsp. Apri 22. 2613 100 Q2AV 1-5005-4000 QUOTE #: vaolasa 171166 TYLEA ST AW CDIELA R.IVER.SIN $1310 (7511/114110 V1913114841 71.11 1.5005-4000 .1.75 wwavv. e, 3 tOnibn0',1 7WO RATINGS CAPACITY RATING - Coolino / Hectic Heatin MODEL ARI RATINGS NOMINAL ELECTRIC HEAT CAPACITY3 (KW) COOLING CAPACITY 80 / 67-95°F SOUND RATING2 MBH SEER EER 240V 480V 00V 10, 15&20 DCE036 40 10.10 9.30 _(12e121_,..e 8.6 5 7, 10, 15&20 7, 10, 15&20 DCE048 48 10.35 9.45 8.6 5 7, 10, 15&20 7, 10, 15&20 10, 15.&20 DCEO60 59 10.15 9:40 8.6 5, 7, 10, 15,20&30 7, 10, 15 20&30 10, 15, 20&30 DCE072 72 ,., ,.., •_ - _„�,_ 9.00 �. 8.4 5, 7, 10, 15,. 20 & 30 7, 10, 15, 20 & 30 10, 15, 20 & 304_ CAPACITY RATINGS - Cooling / Gas Heating 530.18-TG1Y WEIGHT (WT) calc, LBS BASE UNIT WT 645 ECONOMIZER 50 EXSTG ROOF CURB.. 125 TOTAL WT 820 ARI RATINGS GAS HEAT CAPACITY MODEL COOLING CAPACITY SOUND INPUT OUTPUT AFUE S.S.E. S.E. TEMP. GAS 80 / 67-95°F RATING2 RISE LINE SIZE S ER EER _ ...*_MBHI �. (bels (MBH) (MBH) (%) (%) (%) ° DCG036N.040 40 10.10 9.30 8.6 50 40 80.91.031. 81.6 75.9 15-45 1/2 DCG036N079 40 10.10 9.30 8.6 100 79 80.5 80.8 73.6 40-70 1/2 DCG048N060 48 10.35 9.45 8.6 75 60 80.9 81.6 77.3 25-55 1/2 DCG048N099 48 10.35 9.45. 8.6 125 99 80.3 80.6 77.9 45-75 1/2 0CG060N079 59 10.15 9.40 8.6 100 79 80.5 80.8 73.6 25-55 1/2 DCGO6ON099 i .59 10.15 . 9.40: 8.6 125 99 80.3 80.6 77.9 35-65 1/2 DCG072N079 72 - 9.00 8.4 100 79 80.5 80.8 73.6 25-55 1/2 .,i sgQ72N099 _ 72 -m,,_, , 2,00 8 4 125 _ 99 80.3 89.6 77.9. 35-65 1/2 Ratings are in accordance with ARI Standard 210. Sound ratings are in accordance with ARI Standard 270. 3Heaters are available as accessories - all with single point power arppty. SEER = Seasonal Energy Efficiency Ratio - the tote' aod'r: g output In BTU's during a normal annual usage period for cooing divided by the total •metric powerkpd In wefawcas doing the same period EER = Energy Efficiency Ratio - the cooling capacity in Stu's per hour (81uh) divided by the power input In watts at any given set of rating condtons, expressed In BTUH per watt (STUHrwat). AFUE = Annual Fuel Utilization Efficiency - determined in accordance with DOE test procedure. S.S.E. = Steady State EtFdenry. (Percent Output). S.E. = Caifomia Seasonal Efficiency - determined in accordance with test procedures as specified by the Stale a QaEbnt a Energy Commission. Furnaces are ava table with aim NOx sooessory. = Not ARI Usted. SICAL DATA - BASIC U MODELS ,...,.-� .- DCE/DCG 1 .. Ofi0 n7 EVAPORATOR BLOWER CENTRIFUGAL BLOWER (Dia. x Wd. in.) FAN MOTOR HP DIRECT -DRIVE) FAN MOTOR HP (M.T DRIVE) 12 x 10 1/2 1 ..,, - - 12 x 10 3/4 1.5 12 x 10 1 1.5 12 x 11 1 1.5 EVAPORATOR COIL ROWS DEEP FINS PER INCH FACE AREA(So.Ft.) 3 13 3.6 3 13 4.3 3 13 5.1 4 13 5.1 CONDENSER PROPELLER DIA. (in.) FAN MOTOR HP NOM. CFM TOTAL. 22 1/2 4.500 22 1/2 4.200 22 1/2 4.500 1 22 17 1 24 1/2 4.500 2 16 16 7 CONDENSER COIL ROWS DEEP FINS PER INCH FACE AREA (Sa. Ft.) 1 16 17.1 1 19 17.1 AIR FILTERS (SEE NOTE) QUANTITY PER UNIT (14" X 20" X 1") QUANTITY PER UNIT (14" X 25" X 1") TOTAL FACE AREA (sq. ft.) 2 1 6.3 2 1 6.3 2 1 6.3 2 1 6.3 CHARGE . R, , FRI aFRANT 99 fih.S.(. . s 6/B .714 1013 NOTE: Filter racks are adapted for 1' or 2' thick filters. COMPONENT WEIGHTS COMPONENT Basic Unit Options and Accessories DCE (Cooling only) • DCG (Gas / Electric) Economizer Motorized Outdoor Air D Electric Heat (Nominal KW) (DCE only) Roof Mounting Curb Relief / Fixed Air Damper Belt -Drive Blower NOTE: Weights are given in pounds. 1 MODELS CE & DCG IO.t --Alai- _,.9 _5za ... -..LIM. 545 585 610 670 40 Mbh 605 - - 60 Mbh 79 Mbh 615 99 Mbh mper 5-7KW 10 - 15 KW 20-30KW 655 670 680 50 48 18 2.3 28 92 10 5 725 735 Unitary Products Group 3 Existing ROOF CURB DIMENSIONS • (DCE and DCG - 3, 4, 5 & 6 TON) DUCT SUPPORT RAILS 2 TYP, BACK OF UNIT SUPPLY° AIR RE7URN° AIR 37=1/4" DUCT SIZES: Supply Air r 19-1/4" X 19-1/4" Return At r 18•i/4" X 19.1/4" ROOF CURB BENEFITS " COMPRESSOR AND CONDENSER END OF UNIT FRONT OF UNIT 530.18-TG 1 Y Supply and Return Alr (Including duct support raft) shown era typical for Dom duct applications. Far location or hatI7401,111 duct applications (on back of unit), refer to Unk Dimension detach, FRONT VIEW (3-JOIST SUPPORT) NOTE: Both supply air and Mum air duct openkgs am aquas and am the same alga, pro- vidng easy duct Inetaliatlon. Duda can be installed onto the curb from the roof. All electrical w(rinQ connections can be made Inside the curb. UNIT AND CURB APPLICATION FRONT VIEW (2-JOIST SUPPORT) 4' 72' LALTERNATEI The 431E ovoid dad dmanabn slows ductwork penemsdion between roof Joists that are wooed on 46' cotters. 3/4" X 1-1/4" WIDE GASKETING FOR CURB FRAME AND ALL DUCT SUPPORT SURFACES UNIT BASE W000 NAILER UNIT BASE RAILS 14" 8" MIN. ABOVE FINISHED ROOF — 1 COUNTERFLASHING CURB FRAME— CANT STRIP INSULATION AND ROOFING MATERIAL INSULATION ROOF DECK AND SUPPORT STRUCTURE Unitary Products Group 19 BTL l:\(;1\i BRING FILE COPY 19011 Woodinville Snohomish Rd NE, Suite 100 Woodinville, WA 98072-4315 Phone: (425) 814-8448 Fax: (425) 821-2120 Structural Calculations for Bay Valve AC 1 Mech'l Unit Support of Proposed HVAC Unit March 28, 2014 REVIEWED FOR ,ODE COMPLIANCE APPROVED APR 2 2 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 1 6 2014 HP116T14 BTL i.NGINEERING `;- ewv, 0,1 A '1/41.4#14.1e' 4,4.4.i 17924 — 140th Avenue NE, Suite 220 Woodinville, WA 98072-4315 Phone: (425) 814-8448 Fax: (425) 821-2120 Calculations • BTL 17924 — 140th Avenue NE, Suite 220 Woodinville, WA 98072-4315 Phone: (425) 814-8448 Fax: (425) 821-2120 Gravity Support 63/4X36 (TYP) j tic a A 4X16ROUGH D.F. #1 OUTLINE AC-1 OUTUNENL CURB ADAP STINCROOF CUR A' 4X16ROUGH D.F. #1 iP 63/4X36 (TYP) 1 4 X 16 ROUGH D.F. 11 J ,PARTIAL ROOF EQUIPMENT & FRAMING PLAN //8n=,}On . . . ENGINEERING 19011 Wood-Sno Road NE, Suite 100 Woodinville, WA 98072-4436 Phone: 425-814-8448 Fax: 425-821-2120 D M = Co, 70 X-rt 6 /11 7/ 1 A r(0fl 7c--' iy*--0(3-06/,/.5"(k)6/,;,) 'f\x/4, DE HI 3 .Bict -000. . 74/20* 0, 73 ic.-/-7:-/ ro /Cc-) F57 /• r-7/ " /./S _ e/C' /14fi /14 Project: Designed By: Date. Scale. Pae. 6- — z Project Number: Client: BTL 1 NG1 NEFR1 17924 — 140th Avenue NE, Suite 220 Woodinville, WA 98072-4315 Phone: (425) 814-8448 Fax: (425) 821-2120 Seismic Support Bay Valve AC 1 Mech'I Unit Revision Date: 3/28/2014 Occupancy Category: ii - other Structures Seismic Use Group: I /E = 1.00 (Seismic Factor) Is = 1.00 (Snow Factor) /w = 1.00 (Wind Factor) Site Class: Ss = 1.5 `! 51=0.5``'. D Fa = 1.00 F = 1.50 v IBC Table 1604.5 v I ASCE Table 20.3-1 ASCE Table 11.4-1 ASCE Table 11.4-2 Design Spectral Response Acceleration: SMs = FaSs = 1.50 SDS=Z/3 SMS = 1.00 SM1 = FvS1 = 0.75 SD1 = % SM1 = 0.50 Bay Valve AC 1 Mech'I Unit Revision Date: 3/28/2014 0 Seismic Forces Component Operating Weight: 889 Ibs Fp = 0.4 ap SDs Wp Rp / Ip Fp = 427 Ibs Fp need not exceed: Fp = 1.6 SDS Ip Wp Fp = 1422 Ibs Fp shall not be less than: Fp = 0.3 SDS Ip Wp Fp = 267 Ibs Dimensions: x = .46.75 , in y = 74.375 , in z= 17. in Curb Height = 28 in Check Uplift: MOT = 15575 lb -in MRESIST = 18702 lb -in UPLIFT = 333 lb [1+2 (zlh)] ASCE Eq. 13.3-1 ASCE Eq. 13.3-2 ASCE Eq. 13.3-3 x y z Curb Height F.S. = 1.2 5 1.5 NOT O.K. Will Be Resolved By Attachment. See Page 5 _ 3- 5- Z • Br —4 ENGINEERING 19011 Wood-Sno Road NE, Suite 100 Woodinvile, WA 98072-4436 Phone: 425-814-8448 Fax: 425-821-2120 r iet 11C4eop- 4. •C ilk '4' /lea /Vino Ce•friv u 56 IF G/1-ri Srcs.1._ fm.4103- LJ/(2)zittia "cc sciur-do = /4j 5747-4ER (2)W 577Z4P5 goeie(v 5/o/E- 0/ 5-2644 PtJe Gip‘ipr MJ Curio ,ce-o.ctus 37e. .73 Ceveb 26 5#1°t-o- 5-co-etc) (2) cer-ew /-14/0 (0) ect,,5 Aecie4 Side Project: Project Number Client: Designed By: Scale: Date. $ -.3 Page. BTL I'\(;1\1'I RI\( 17924 — 140th Avenue NE, Suite 220 Woodinville, WA 98072-4315 Phone: (425) 814-8448 Fax: (425) 821-2120 Details FA57ENAC-1 TONEW CURBADAPTER WITH 18-G4 S EEZ STRAP; (2) #10SlREWS T11RUS7RAPINTO AC-184SERA!L, (2) #10SLREWS'TNRUSTRAP INTONEW CIRI3 NWT& (2) S7RAPS EACH CORNERR (8) S7RAPS TOTAL (4) SCREWS EAQf S7R4P, (32)SCREYYSTOTAL NEW WRIT AD4PTER FASTEN NEW CURB ADAPTER TO &17577NG ROOF CURB WITH #10SCREWS; (2) SOWS MCISIDE (2) SCREWS EAOf END. (8) TOTAL SCREWS. EXISTINGROOF CURB SIDE VIE W A -A' END VIE W B -B' AC-1 ATTACHMENT DETAIL NOT TO SCALE City of Tukwila Department of Community Development 10/1/2014 Jim Haggerton, Mayor Jack Pace, Director MARK SMELTZER 112 CENTRAL AVE S KENT, WA 98032 RE: Permit No. M14-0084 BAY VALVE SERVICE, INC. 4385 S 133 ST Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/9/2014. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/9/2014, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M14-0084 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0084 DATE: 04/16/2014 PROJECT NAME: BAY VALVE SERVICE INC SITE ADDRESS: 4385 S 133 ST X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: /4-3- ,WC ` 19'1 vi Building Division M Public Works n MA i/A- y• Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 04/17/14 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 05/15/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERFORMANCE HEATING & A/C TNC Page 1 of 2 Washington State:Department of Labor & Industries PERFORMANCE HEATING & A/C INC Owner or tradesperson MILLER, DANIEL E Principals MILLER, DANIEL E, PRESIDENT ERDAHL, DARRIN, VICE PRESIDENT GOWIN, RICHARD L, VICE PRESIDENT (End: 04/26/2011) GOWIN, CONSTANCE F, VICE PRESIDENT (End: 11/15/2007) Doing business as PERFORMANCE HEATING & A/C INC WA UBI No. 600 601 386 1012 Central Ave S KENT, WA98032 425-251-0356 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. PERFOHA15ORT Effective — expiration 12/30/1985— 04/30/2015 Bond DEVELOPERS SURETY & INDEM CO Bond account no. 748802C Received by L&I 11/27/2007 Insurance American Fire & Casualty Co Policy no. BKA56064545 Received by L&I 04/21/2014 Active. Meets current requirements. $12,000.00 Effective date 10/01/2007 $1,000,000.00 Effective date 04/28/2014 Expiration date https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600601386&LIC=PERFOHA150RT&SAW= 05/13/2014