Loading...
HomeMy WebLinkAboutPermit M14-0095 - PSF MECHANICAL INC - HVAC SYSTEMSPSF MECHANICAL 11621 E MARGINAL WAY S EXPIRED 08/19/15 M14-0095 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 1023049044 Permit Number: 11621 E MARGINAL WAY 5 BLDG 7 Issue Date: Permit Expires On: Project Name: PSF MECHANICAL INC M14-0095 5/28/2014 11/24/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: „ WA, KAREN GEORGE Phone: (206) 812-7678 P S F MECHANICAL, INC. Phone: (206) 764-9663 9322 14TH AVENUE SOUTH , SEATTLE, WA, 98108 PSFMEI*090NZ Expiration Date: 10/3/2015 9322 14 AVE S , SEATTLE, WA, 98108 DESCRIPTION OF WORK: RENOVATE EXISTING HVAC SYSTEMS TO BETTER SERVE NEW TENANT LAYOUT TO INCLUDE COMBINATION OF NEW AND EXISTING EQUIPMENT. THREE OF FOUR ROOFTOP A/C UNITS WILL BE REUSED (THE FOURTH WILL REMAIN FOR FUTURE TENANT EXPANSION). ONE UNIT TO SERVE THE PERIMETER ZONES USING VARIABLE AIR VOLUME WHILE THE (2) SMALLER UNITS SERVE THE INTERIOR ZONES USING CONSTANT VOLUME. NO ADDITIONAL CAPACITY IS TO BE ADDED. Valuation of Work: $295,000.00 Type of Work: Fuel type: Fees Collected: $3,490.12 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: ,a4.1.4'i Print Name: Date: - a 2 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 8: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 4: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 5: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 2: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 6: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 7: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 3: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 11: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 1: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 9: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 10: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 12: ***MECHANICAL PERMIT CONDITIONS*** 13: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 14: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 1800 MECHANICAL FINAL 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWIL Community Development i,epartment Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit Project No. Date Application Accepted: Date Application Expires 'oro MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 1023049044 Site Address: 11621 EAST MARGINAL WAY S 98168 Suite Number: Floor: Tenant Name: PSF Mechanical, Inc. PROPERTY"OWNER Name: Heartwood Properties LLC Address: 9322 14th Ave S City: Seattle State: WA zip: 98108 'CONTACT PERSON, communication Name: Karen George erson receiving all project Address: 9322 14th Ave S City: Seattle State: WA zip: 98108 Phone: (206) 812-7678 Fax: (206) 812-7679 Email: kgeorge@psfinech.com New Tenant: J Yes ❑..No MECHANICAL CONTRACTOR INFORMATION Company Name: PSF Mechanical, Inc. Address: 9322 14th Ave S City: Seattle State: WA Zip: 98108 Phone: (206) 812-7678 Fax: (206) 812-7679 Contr Reg No.: PSFMEI*090NZ Exp Date: 10/03/2015 Tukwila Business License No.: 0102293 Valuation of project (contractor's bid price): $ 295, 000 Describe the scope of work in detail: Use: See Back Residential: Commercial: New ❑ Replacement ❑ New 0 Replacement 0 Fuel Type: Electric ❑ Gas 0 Other: H:Wpplications\Fonns-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-1I.docx Revised: August 2011 bh Page 1 of 2 Print Name: Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/walUfloor mounted heater Appliance vent Repair or addition to heatlrefrig/cooling system Air handling unit <10,000 cfm 1 2 Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct 4 Ventilation system 1 Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser 1 59 Thermostat 1 8 Wood/gas stove Emergency generator Other mechanical equipment 2 Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW ER OR AUTHO IZED AGENT: Signature: A/Lt 4 Karen George Mailing Address: 9322 14th Ave S Date: -7 _ Day Telephone: (206) 812-7678 Seattle WA 98108 City State Zip SCOPE OF WORK THE SCOPE OF WORK WILL RENOVATE THE EXISTING HVAC SYSTEMS TO BETTER SERVE A NEW TENANT AND OFFICE LAYOUT. THIS WILL BE DONE USING A COMBINATION OF NEW AND EXISTING EQUIPMENT. THREE OF THE FOUR ROOFTOP AIR CONDITIONING UNITS WILL BE REUSED, WHILE THE FOURTH WILL REMAIN FOR FUTURE TENANT EXPANSION. ONE UNIT WILL SERVE THE PERIMETER ZONES USING VARIABLE AIR VOLUME WHILE THE TWO SMALLER UNITS WILL SERVE THE INTERIOR ZONES USING CONSTANT VOLUME. NO ADDITIONAL CAPACITY IS TO BE ADDED. H:Wpplications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT I QUANTITY I PAID PermitTRAK $3,650.77 M14-0095 Address: 11621 E MARGINAL WAY S BLDG 7 Apn: 1023049044 $2,818.94 MECHANICAL $2,684.70 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $2,652.20 TECHNOLOGY FEE $134.24 TECHNOLOGY FEE R000.322.900.04.00 0.00 $134.24 PG14-0068 Address: 11621 E MARGINAL WAY 5 BLDG 7 Apn: 1023049044 $831.83 GAS $121.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $65.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $24.38 PLUMBING $671.50 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $639.00 TECHNOLOGY FEE $38.45 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2223 R000.322.900.04.00 0.00 $38.45 $3,650.77 Date Paid: Wednesday, May 28, 2014 Paid By: PSF MECHANICAL INC Pay Method: CHECK 115106 Printed: Wednesday, May 28, 2014 4:15 PM 1 of 1 CISYSTEMS Cash. Register Receipt City of Tukwila Receipt Number R1969 DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $671.18 M14-0095 Address: 11621 E MARGINAL WAY BLDG 7 Apn: 1023049044 $671.18 MECHANICAL $671.18 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R1969 R000.322.102.00.00 $671.18 $671.18 Date Paid: Tuesday, April 29, 2014 Paid By: PSF MECHANICAL INC Pay Method: CREDIT CARD 07601G Printed: Tuesday, April 29, 2014 3:53 PM 1 of 1 CP'SYSTEMS INSPECTION RECORD Retain a copy with permit IN S€'E iON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (2 6) 431-3670 Permit Inspection Request Line (206) 438-9350 tea 1 Project. (S F meat. E)f Gam- Type of Inspection: —gam/ d6tec- j Address: 1((2-I t "a%eirf (tat 4Ay 541 Date Called: Special Instructions: �� _ +�y(7 t , 11 - (Y p.m. -- Date Wanted: a,a.m.,4q Reques rt---e I IDS.,00(eCIA Phone �,7(q , 17�.7 QApproved per applicable codes. ECorrections required prior to approval. COMMENTS: !' �a v / dl-f Ye T' / 11 G( b cfii9 G'Fr r^ cy 1 poi/q/ Inspector: zr-C l n REINSPECTION FEE REQUIRED. Prior to next inspection. tee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Datt. _ 2.r) — % �-" INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 f Project: Type 91 inspecition:s, 14.0.14 .A4dress: Ackr,(04 1 (417..c s Date Called. Special Instruction444 0 (ays: i Date : a.m. Wanted Requester:,"f/t C( r e-- it) Thr -A e Phone No: 7 q -Approved per applicable codes. ElCorrections required pria to approval. COMMENTS: KAA oF-6-r`ces inspector Date:2._ n REINSPECTION FEE REQUIRED. Prior to next inspedion, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INS CTION NO. PERMIT NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd,, #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 1014- LA.5 Project: .P.F AAP.dni Type of Insoeclion: /6,_ k, Pi- , NV Address: i 102-1 t• Mitr69'',JAL Date Ca lled: ? ...-----, Special Instructions: Date Wanted: - 5" — p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS f() Date: I - 5 5 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100, Catt to schedule reinspection, INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd,, #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 nivzi- 0 oq. Project: P5 F Me (A 1 Type of Inspection : R A 00+ 1-- Ai M tdie\ Address: , / / LP 2,- / f:___ Date Called: Special Instructions: ,,, Date Wanted: -- / 4 Lill,. 13:in• 'Requester. phorre, No: 0 ___ 3,1 8, ...3 1 ... 0 EiApproved per applicable codes. Corrections required prior to approval. COMMENTS: 14- c-toizNre rd.) oe -odp L 11) Inssiector: Date:/ 2 - REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Bbrd., Suite 100. Cali to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project,;`, T "1' Type of Inspection:w � t`Z(}l c, i'V Addre s: t I (n2-I '._0(1 A( wilt Date Called: Special Instructions: Date Wanted: I C) -- II -" 1 Ll t; a ink P.m. Requester: Ph?_0(o 3 1 o9 ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: ((/) A/4,-d 6)7/6._ - .>,t.i(/Tod 1 Inspedtor: / X— e'› C., 7,REINSPECTION FEE REQUIRED. Prior to tSext inspection, fee must be paid at 6300 Southcenter BlvdiSuite 100. Call to schedule reinspection. Date: /_/7 /l City of Tukwila Department of Community Development 7/1/2015 KAREN GEORGE 9322 14 AVE S SEATTLE, WA 98108 RE: Permit No. M14-0095 PSF MECHANICAL INC 11621 EAST MARGINAL WY S Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 8/19/2015. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 8/19/2015, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M14-0095 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development 10/1/2014 Jim Haggerton, Mayor Jack Pace, Director KAREN GEORGE 9322 14 AVE S SEATTLE, WA 98108 RE: Permit No. M14-0095 PSF MECHANICAL INC 11621 EAST MARGINAL WY S Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/24/2014. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/24/2014, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M14-0095 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0095 DATE: 04/29/2014 PROJECT NAME: PSF MECHANICAL SITE ADDRESS: 11621 EAST MARGINAL WY S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: VU Building Division Public Works n 4IAA Fire Prevention Structural Planning Division Permit Coordinator ❑ PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 05/01/14 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required n n Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: rec�,�i N e M p. 0 DUE DATE: 05/30/14 n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 P S F MECHANICAL INC Page 1 of 3 Washington State Department of Labor & Industries P S F MECHANICAL INC Owner or tradesperson REYNOLDS, JAMES P Principals REYNOLDS, JAMES P, PRESIDENT READ, ANDREW A, PRESIDENT BEARDSLEY, WARREN SCOTT, SECRETARY CRITCHLOW, JAMES D (End: 09/27/2011) Doing business as P S F MECHANICAL INC WA UBI No. 601 318 369 9322 14TH AVE S SEATTLE, WA 98108 206-764-9663 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. PSFMEI*090NZ Effective — expiration 08/09/1991— 10/03/2015 Bond Active. Meets current requirements. Travelers Cas & Surety Co $12,000.00 Bond account no. 105975899q Received by L&I Effective date 03/13/2014 03/13/2014 Bond history Insurance Liberty Mutual Fire Insurance Policy no. TB2-Z91-452741-023 $1,000,000.00 Received by L&I Effective date 09/27/2013 10/01/2013 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601318369&LIC=PSFMEI*090NZ&SAW= 05/28/2014