HomeMy WebLinkAboutPermit M14-0100 - PETSMART - ROOFTOP UNITS REPLACEMENTPETSMART 17585 SOUTHCENTER PKWY EXPIRED 11/24/2014 M14-0100 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2623049067 17585 SOUTHCENTER PKWY Project Name: PETSMART Permit Number: M14-0100 Issue Date: 5/28/2014 Permit Expires On: 11/24/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: CLPF-TUKWILA LP 10655 NE 4TH ST #901 C/O JSH PROPERTIES INC, BELLEVUE, WA, 98004 DAVE ZIGWEID 5009 PACIFIC HY E, STE 9 , FIFE, WA, 98424 GSC MECHANICAL LLC 5009 PACIFIC HWY E STE #9 , TACOMA, WA, 98424 GSCMEML866BB Phone: (253) 625-1936 Phone: (253) 235-5692 Expiration Date: 1/2/2016 DESCRIPTION OF WORK: REPLACEMENT OF (6) ROOFTOP UNITS Valuation of Work: $0.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $481.06 Electrical Service Provided by: PUGET SOUND ENERGY Water District: HIGHLINE,TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Signature: Date:Ic)�/7L/ I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction-o'rthe performance of work. I am authorized to sign and obtain this development permit and agree to the -cord ions attacke,c1 to this permit. Signatur Print Name` :!)--i Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 9: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 4: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 5: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 2: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 6: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 7: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 3: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 8: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 1: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 10: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 11: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 12: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 13: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 14: Readily accessible access to roof mounted equipment is required. 15: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 16: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 17: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 18: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 19: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 20: ***MECHANICAL PERMIT CONDITIONS*** 21: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 22: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 23: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Mechanical Permit No. Jt It" 00 Project No. Date Application Accepted: (}� Date Application Expires: l� l (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: �� S C&S 54\-\ C,ctt SZQkk � Tenant Name: 5, s.`(\ . PROPERTY OWNER Name: h \-_ S�-^\ Address: \c\ 100 \ N a`+r, 4- City: cioN y.\ State: (� Zip: ��\ CONTACT PERSON — person receiving all project communication Name: Address: C sic City,_(State: \1\5\ Zip�� PhoneS3 _t, _ 1 o\-)1 Fax: D.-?) _cats_ 6=--?•*7 Email: p�\ C..1W-s.• C LX\� ®c) • C-c fN King Co Assessor's Tax No.: t Suite Number: Floor: New Tenant: ❑ Yes N..No MECHANICAL CONTRACTOR INFORMATION Company Name: (� c C � , -; C��ILK Address: sdd: citkCA ;L 1 fi\�` ` t� City -S State: t , s Zip 1 D \."6.1 Phones_ z)'3 /S-Q Fax:a's g ,. c c 7 Contr Reg No.:Gsc r mLgO Exp Date: 11 .16 1,4 Tukwila Business License No.:us_ Opk,:\S�a� Valuation of project (contractor's bid price): $ \ e0 1,.5z Describe the scope of work in detail: c. +c,cz\riN% b cZ k)d� Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Ibl Fuel Type: Electric jj Gas Other: H:Wpplications\Porms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >I00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AG Signature: Date: Print NameOC1-\4 rZ \ �W R \ Day Telephone:' S' Mailing Address: 6a11::\ ��•��� �� �W�J� City State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-1 l docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila • DESCRIPTIONS I ACCOUNT I QUANTITY PermitTRAK I PAID $481.06 M14-0100 Address: 17585 SOUTHCENTER PKWY Apn: 2623049067 $481.06 MECHANICAL $462.56 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $337.55 PLAN CHECK FEE R000.322.102.00.00 $92.51 TECHNOLOGY FEE $18.50 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2103 R000.322.900.04.00 $18.50 $481.06 Date Paid: Tuesday, May 13, 2014 Paid By: GSC MECHANICAL LLC Pay Method: CREDIT CARD 091125 Printed: Tuesday, May 13, 2014 8:17 AM 1 of 1 CfSYSTEMS INS INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Proj t: Type of Inspection: Address: i Cv i S Se lA,) Date Called: Spec,ai Instructions: Date Wanted: i� "' L � a.m. Requester: 1( Phone No: "S 3 (fl Z l ci l r Approved per applicable codes. Corrections required prior to approval. *COMMENTS; '. I. k k1t r1b=7tic � 6 A ._i ILi i # `` tor: I Date: 1 INSPECTION FE REQUIRED, Priol to next inspection, fee must be id at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Google Maps Page 1 of 1 P-asins\P4 D. 10� -3 (Ac\O /v7 REVIEWED FOR I CODE COMPLIANCE APPROVED MAY 232014 RECEIVED CITY OF TUKWILA MAY 1 3 2014 PERMIT CENTER City of Tukwila BUILDING DIVIS!C? )kA 0 e, ro 0 Imagery 02014DigitalGlobU.S. Geological Survey, USDA form Service Agency. Map data C 2014Google 200fr v https://www.google.com/maps/@47.4444838,-122.2630639,543m/data=!3m1 ! 1e3 5/12/2014 2012 Washin ton State Ener. Code Com.liance Forms for Commercial Grou. R1 and > 3 sto R2 and R3 Mechanical Summary d lian r Commercial, Group R1, and > 3 story R2 & R3 MECH-SUM Revised June 2013 Projec -v a 4' _jectAddress + p.4 m�A, AT 3�-7 `c_ Date 05 S•S CA- . 5?1/4St-\A''p� For Building Dept. Use C IV j \>_\<-,w , \N. ,\`&b Ap licant Name: &Sc �( iss.( � c �-I J Prle �` Ap IicantAddress:t��;Ss \ c \ • ,S.2 �b*91 bra Ap• icant Phone: �,5 ^3 - C6' _ \'s� AA R Project escRM 1 ur vv"a (MS1� Briefly desc ��f� t1 'V D system type eatures. Includes Plans �`m� cR k.C�v `� ?� o C Re* C'- v k cj Q 'r� ` QCj c Od) i n c. \—\Q., ,� (1.-) `IP\ .(p( R Include documentation requiring compliance with commissioning provisions per Section C408. Compliance Option (Dimple System Oomplex System Dystems Analysis Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Nam& Model No.' Capacity2 Btu/h OSACFM or Econo? SEER o lib IPLV3 Econmizer Option or Exceptions Heat Recovery Y/N Q\ \)\ 1 1\N a\(. 1-GM 1Z-)4%-\JAE LCcl) &Q-\O \ IQ,Ii\\ \SoSym 3 ZCQr \\ •0 o Q%\ i' ��� 1_e, c, o x 1-G)Ao \\tkt Zcev \D. ' G�oLS.\ 11) —) �I v\ .1-Zf nG 1GV(Oc\ Ail-kS) (ioo10 E c.Or10 \�bc C9Q).\ to Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu/h OSA cfm or Econo? Input Btuh Output Btuh Efficiency" Heat Recovery Y/N \ la2.1-141G- )K (.34< MR \�OQCA Cc ISO \ O© �io10 10 3;i 4 c2.,‹ \I\ ) o A (\ & Lc- k �0 S I m rOZzO c, o \° °r Ra47 v t) ,� L 1 ti � a���no K. �r \�®-ia�\�r � cow 1 1 .s1(1)) `,00 'i ) --1 Leny\e� 1c,v-\ \-\�Q 11°,� c.,,,, A. ‘,...:1- Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' CFM SP' � ` HP BHP Flow Controls Location of Service \ W .\•) 11Z,‘<1 n,4 LC")- k A' E kcv .15 C U �-) v -1, Z\IN ).y.Gx .G1-\1S1.0\ (3z.0 ,c C. \J _ aNc b RrS`1\ )_es(\m--x- 1.6\-1G- \-\IA Z ,00 C v \' Q-\,,o;1 K \s, 1.eh © \�`\ ' 4%3 Z •0O Q l.1 oq- \),,,N _ Service Water Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Input Capacity Sub - Category Er Location of Service 1 If available. 2 As tested according to Table C403.2.3(1)A thru C403.2.3(8). 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume (VAV), constanj�>;glu grxariable speed (VS). 6 Economizer exception number per Simple Systems C403.3.1 or Complex Systems C403.4.1. 7 Efficiency Fact 22 CITY OF TUKWILA MAY 1 3 2314 PERMIT CENTER MILHO 100 Burns & DeHavG laus, Pyle, Scho r* [ JJ © So*h Mai Sexeet Akron, OH 44311 ma ci." vrr. sapns em.7► o+r..e x City of Tukwila, Washington Community Development Department 6300 Southcenter 81vd., 0100 Tukwila, WA 98188 RE: PetSmart HVAC Replacement Structural Letter of Conforma ;tore Information Store Number: 0377 Street Address or Intersection: 17585 SW Pkwy City and State: Tukwila, WA To whom it concems, Suite 2531 REVIEWED FOR CODE COMPLIANCE nce APPROVED MAY 2 3 2014 City of Tukwila BUILDING DIVISION tel 330.572.2100 fax 330.572.2101 www.gpdgroup.cont 05/12/14 2014024.03 CITY OF.TUKWIt.: MAY 13 PERM'T The following memorandum serves to provide information regarding the structural evaluation for the'PetSmart HVAC Roof Top Unit (RTU) replacement program. PetSmart has requested Glaus, Pyle, Schomer, Bums, and Dehaven, Inc. (dba, GPD Group) to evaluate the existing roof structure, for Store ID number 0377 to determine if the existing roof structure is adequate to support the proposed HVAC replacement units. it has been assumed that the existing structure was designed in accordance with industry standard design procedures and local adopted building codes by a licensed design professional and built in accordance with the design drawings and generally accepted building practices. The new RTU's will be placed In exactly the same locations as the existing units they replace. It has been assumed that the existing units have been accounted for in the original design and that no modifications have been made since original construction. GPD Group shall be notified in writing of any deviations from this design premise. GPD Group has received and reviewed the existing building site survey provided by Retail Construction Management Services (RMSe) on the roof framing supporting the existing RTU's. information obtained from the site survey along with the information from Lennox regarding the new unit weights, have been summarized in Table 1 below. • e..s.at.. ,over en,i Dmnne.el WVAr Infnrm'tien* Store 0 0377 Tukwila, WA RTU 0 Existing HVAC Data New HVAC Data Preliminary Analysis Size (T) MFR Model Number Weight (Total) (T) MFR Model Number Number RTU Weight (lb) Total Weight (ibs) Weight Change Unit Curb Total 1 4 TRANE YCD048C4LCBD 543 4 LENNOX LGH048H4E 707 707 ! 107.44 814.44 271.44 i 509L - 2 7.5 LENNOX LGA090H2BS3G NOT BEING REPLACED 3 12.5 TRANE YC0150C4LGAA 1533 12.5 LENNOX LGH150S4M 1292 1292 215.25 1507.25 -25.75 -2% 4 12.5 TRANE YCD15OC4LGAA 1533 12.5 LENNOX LGH150S4M 1292 1292 215.25 1507.25 -25.75 -2% 5 12.5 TRANE YC015004LGAA 1533 12.5 LENNOX LGH150S4M 1292 1292 215.25 1507.25 -25.75 -2% 6 6.25 TRANE YC0075C4LGBD 820 6 LENNOX LGH072H4B 953 953 210.39 1163.39 343.39 42% 7 7.5 TRANE YC0090D4L.CBD 868 7.5 LENNOX LGH092H4B 1200 , 1200 168.56 1368.56 500.56 58% 8 7.5 LENNOX LGA09OH2BS3G NOT BEING REPLACED 9 4 LENNOX LGA048H28SG NOT BEING REPLACED 10 3 LENNOX LGA036H2BS2G NOT BEING REPLACED 11 4 LENNOX LGA048H2B53G ' NOT BEING REPLACED 12 3 LENNOX LGA036H28S2G NOT BEING REPLACED *Existing HVAC data (unit manufacturers and models only) has been provided by the Installing contractor, Lennox NAS, on 03/20/2014. The proposed (new) HVAC data has been provided by Lennox on 03/20/2014. Ail information is considered to be accurate on the date that it was received. AAt1-OLcO PetSmart Store 0377 Tukwila, WA 2 May 12, 2014 GPD Group's design approach was to evaluate the existing roof members for conformance to the requirements of the International Building Code. The 2012 International Existing Building Code, section 706.2, exception 1, has been referenced to show that a weight less than or equal to 5%, if any, has been deemed structurally acceptable per the code. The referenced section is as follows: 706.2 Addition or replacement of roofing or replacement of equipment. Where addition or replacement of roofing or replacement of equipment results in additional dead loads, structural components supporting such reroofing or equipment shall comply with the gravity load requirements of the International Building Code. Exceptions: 1. Structural elements where the additional dead Toad from the roofing or equipment does not increase the force in the element by more than 5 percent. In the following analyses of the roof joists supporting RTU's 1, 6, and 7, the joists were analyzed using a uniform dead load of 20 psf and a uniform snow load of 20 psf In conjunction with equipment loads . Analysis of foists swooning RTU #1 Existing RTU Weight: 543 Ibs New RTU Weight: 814.44 Ibs (including curb adapter) Existing Joist Framing Member Size: 24" Deep K Joist Joist Spacing: 6 ft on center Span: 34.083 ft The new HVAC will be placed in the same location as the existing unit which is approximately 3 ft± from the edge of unit to the end of the Joist. The unit is supported by two (2) joists, with a joist located on either side of the unit. Load applied to joist framing from the RTU is taken as 2/3rds the RTU weight. This load is then halved and used as point loads at the corners of the unit. Maximum Load From Existing RTU on Joist = 543 Ibs x 2/3 x 1/2 = 181 Ibs @ 3 ft t & 7.25 ft ± Maximum Load From New RTU on Joist = 814.44 Ibs x 2/3 x 1/2 = 272 lbs @ 3 ft ± & 7.25 ft ± IEBC Load Check (Check Bending & Shear Forces) Existing loading Condition Max. Moment = Max. Shear = New Loading Condition Max. Moment = Max. Shear = 12382 ft-lbs 4173 Ibs 12802 ft-lbs > 12382 ft-lbs 4327 lbs > 4173 Ibs Increase in Bending Stress = 3.39% < 5% Satisfactory per IEBC Section 706.2, Exception 1 Increase in Shear Stress = 3.69% < 5% Satisfactory per IEBC Section 706.2, Exception 1 • PetSmart Store 0377 Tukwila, WA Analvsls of loists.suoaorting RTU fib Existing RTU Weight: New RTU Weight: 3 820 Ibs 1163.4 lbs (including curb adapter) Existing Joist Framing Member Size: 24" Deep K Joist Joist Spacing: 6 ft on center Span: 34.917 ft New HVAC will be placed in the same location as the existing unit, approximately 10 ftt from the edge of unit to the end of the joist. The unit is supported by two (2) Joists, with a joist located on either side of the unit. Load applied to joist framing from the RTU Is taken as 2/3rds the RTU weight. This Toad is then halved and used as point Toads at the corners of the unit. Maximum Load From Existing RTU on Joist = 820 ibs x 2/3 x 1/2 = 205 lbs @ 10 ft ± & 14 ft t Maximum Existing Trapezoidal Gravity Load from Drift on Joists = 45psf x 6 ft = 270 pif @ peak Note: drift bad provided is the maximum drift load at joist bearing adjacent to parapet and tapers to zero (0) pif at 12'-6" from joist bearing. Maximum Load From New RTU on Joist = 1163.39 Ibs x 2/3 x 1/2 = 2911bs @ 10 ft t & 14 ft t IEBC Load Check (Check Bending & Shear Forces) Existing Loading Condition Max. Moment = Max. Shear = New Loading Condition Max. Moment = Max. Shear = 42116 ft-lbs 2731:8 Ibs 43217 ft-ibs > 42116 ft-Ibs 2844.4 lbs > 2732 lbs Increase in Bending Stress = 2.62% < 5% Satisfactory per IEBC Section 706.2, Exception 1 Increase in Shear Stress = 4.13% < 5% Satisfactory per IEBC Section 706.2, Exception 1 Anatvsis of foists su000rtint RTU #7 Existing RTUWeight: New RTU Weight: 868 lbs 1368.6 lbs (including curb adapter) Existing Joist Framing Member Size: 24" Deep K Joist Joist Spacing: 6 ft on center Span: 34.083 ft New HVAC will be placed in the same location as the existing unit, approximately 0 ftt from the edge of unit to the end of the joist. The unit is supported by two (2) joists, with a joist located on either side of the unit toad applied to Joist framing from the RTU is taken as 2/3rds the RTU weight. This bad is then halved and used as point loads at the corners of the unit. Maximum Load From Existing RTU on Joist = 868 Ibs x 2/3 x 1/2 = 289 ibs @ 0 ft 1 & 4.5 ft 1 Maximum Load From New RTU on Joist = 1368.56 Ibs x 2/3 x 1/2 a 457 ibs @ 0 ft ± & 4.5 ft t May 12,2014 PetSmart Store 0377 Tukwila, WA IEBC Load Check (Check Bending & Shear Forces) Existing Loading Condition Max. Moment = Max. Shear New Loading Condition Max. Moment: Max. Shear e 15748 ft-Ibs 3359.5 Ibs 16341 ft-Ibs > 15748 ft-lbs 3504.6 Ibs > 3360 Ibs Increase in Bending Stress = 3.77% < 5% Satisfactory per IEBC Section 706.2, Exception 1 Increase in Shear Stress is 4.32% < 5% Satisfactory per IEBC Section 706.2, Exception 1 May 12, 2014 Based on the available information and the analysis performed we are of the opinion that the amount of stress increase in the structural members that support the new HVAC units at rooftop locations RTU-1, RTU-6, and RTU-7 fails within the acceptable range of stress increase permitted by the IEBC, and therefore the roof members to question are adequate for the new equipment bads. Since the unit weights of the new HVAC units that will replace the existing units at RTU-3, RTU-4 and RTU-S are less than the weights of the existing units, we are of the opinion that the existing roof Joists are adequate for the support of the new equipment. For this reason, we request a permit be granted for the work to replace the existing HVAC units. If further information is to be provided, please contact our office as soon as possible. Thank you for giving us the opportunity to provide engineering services for the PetSmart HVAC replacement program. Sincerely, Reviewed by: Stephen H. Cook, P.E. Engineer Ka . • , P.E., S.E. anager / Senior Structural Engineer Lennox Industries Inc. - Product Submittal FYI Ire 011,44% System 1fD: RTUV Package Model: LGH048H4E Description: PKGGE/4TON7CONFIGURABLE HEATING PERFORMANCE Heat Source WE Lowlnput WE LowOutput WE Highlnput H/E HighOutput System HeatOutput Natural Gas 105000 (Btuh) 85500 (Btuh) 150000 (Btuh) 120000 (Btuh) 120000 (Btuh) Gas Supply Connection H/E Heat Rise AFUE/ ThermalEff Number of Heating Stages Gas Supply Pressure 0.50 (in.) 69.4 (°F) 80 2 7 (in.WC) COOLING PERFORMANCE Refrigerant ART EER ARI SEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Coil NetTotalCool Coil GrossSensCool Coil NetSensCool Environ Refrigerant Charge R-410A 12.8 17.0 3800 (W) 50100 (Btuh) 49000 (Btuh) 50100 (Btuh) 48313 (Btuh) 37575 (Btuh) 35788 (Btuh) 5 LBS. 8 OZ. Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 1 2 1.00 (in.) 95.0 (°F) 80.0 (°F) 67.0 (°F) 56.9 (°F) 56.5 (°F) 58.0 (°F) 57.0 (°F) 11.8 (lb/hr) 11.8 (lb/hr) SUPPLY FAN PERFORMANCE Supply Fan Total Air Flow Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM Motor Torque Pct 1600 (cfm) 1600 (cfm) 0.80 (in.WC) 0.75 (hp) 0.75 (hp) MSAV Direct Drive 1179 (rpm) 64 TotalStaticPress Wet Coil Static Press Gas H/E Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 1.00 (in.WC) 0.12 (in.WC) 0.04 (in.WC) 0.04 (in.WC) 4 16.0 (in.) 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range-Nom Voltage 460V 3Ph 60 (Hz) 14.0 (amp) 15 (amp) 6.4 (amp) 11.6 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA 3.1 (amp) 2.1 (amp) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 47.0 (in.) 85.3 (in.) 38.9 (in.) 707 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 18.0 (in.) 29.0 (in.) 11.0 (in.) SOUND Outdoor Sound Rating 75 (db) Project: 3000409543 PetSmart #377 - Tukwila Quote: 4000487479 PetSmart #377 - Tukwila Page 3 of 23 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 3 2014 City of Tukwila BUILDING DIVISION Las Pre Ph RECEIVED CITY OF TUKWILA MAY 1 3 2314 Changed: TINA J. HANEY ared On: 2014-03-25 PERMIT CENTER ne: 972-497-6260 kA1L1-OOO Lennox Industries Inc. - Product Submittal System ID: RTU 4 Package Model: LGH048H4E Description: PKGGE/4TON/CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Copeland Scroll Compressor Pre -charged Refrigeration System Expansion Valves High Capacity Driers Auto reset high & low pressure switch with strike 3 lockout feature in Prodigy unit controller Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Timed Off Control AGA-CGA Certified Units will operate cooling down to 0 degrees F (-17.7 degrees C) without additional controls. Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Aluminized Steel Inshot Burners Separate Compressor and Controls Compartment Advanced controls with Prodigy Control System Limited warranty on aluminized heat exchanger of 10 years Limited compressor warranty of 5 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED GLOBAL ECONOMIZER MULTI -STAGE AIR VOLUME HINGED ACCESS DOORS ENVIRON COIL SYSTEM DISCONNECT - WEATHERPROOF GFCI - FACTORY INSTALLED/FIELD WIRED BY ELECTRICIAN NOVAR LSE IMC INTEGRATION RA SMOKE DETECTOR STANDARD CAP 2 IN MERV4 FILTER BAROMETRIC RELIEF DAMPERS Project: 3000409543 PetSmart #377 - Tukwila Quote: 4000487479 PetSmart #377 - Tukwila Page 4 of 23 Last Changed: TINA J. HANEY Prepared On: 2014-03-25 Phone: 972-497-6260 Lennox Industries Inc. - Product Submittal System ID: RTU 4 Package Model: LGH048H4E Description: PKGGE/4TON/CONFIGURABLE DIMENSIONS - INCHES (MM) CORNER WEIGHTS CENTER OF GRAVITY Model No. AA BB CC DD EE FF GG HH Ibs. kg Ibs. kg Ibs. kg Ibs. kg in. mm in. mm in. mm in. mm LGH036 Std. Unit 98 45 119 54 192 87 158 72 38.5 978 18 457 29 737 46.75 1187 LGH036 Max. Unit 132 60 149 68 241 109 213 97 40 1016 18 457 29 737 45.25 1149 LGH048 Std. Unit 104 47 126 57 202 92 167 76 38.5 978 18 457 29 737 46.75 1187 LGH048 Max. Unit 140 64 158 72 255 116 225 102 40 1016 18 457 29 737 45.25 1149 LGH060 Std. Unit 118 54 144 65 232 105 191 87 38.5 978 18 457 29 737 46.75 1187 LGH060 Max. Unit 159 72 179 82 289 131 256 116 40 1016 18 457 29 737 45.25 1149 LGH072 Std. Unit 132 60 160 73 258 117 212 96 38.5 978 18 457 29 737 46.75 1187 LGH072 Max. Unit 167 76 189 86 305 138 269 122 40 1016 18 457 29 737 45.25 1149 Std. Unit - The unit with NO OPTIONS. Max. Unit - The unit with ALL OPTIONS Installed. (Economizer, etc.) 45 (1143) —a I 1 (25) Pot 1 1 I col 47 (1192) BASE END VIEW Project: 3000409543 PetSmart #377 - Tukwila Quote: 4000487479 PetSmart #377 - Tukwila Page 5 of 23 5518 11 16-1/4 18 143 (279) (413) (457) BB 47 (1192) BASE 7 ( 78) 29 (737) oc M 3-1 LIFTING HOLE (For ri99n9) DD r 26-1/2 (673) BOTTOM RETURN OPENING BOTrOM AIR SUPPLY/ AIR OPENING CENTER OF GRAVITY 6-5/B 168 (654) 9-1/2 (241) I CC EE BOTTOM BOTTOM POWER ENTRY CONDENSATE OUTLET 3 X 8 (76 X 203) TOP VIEW (Base) 83.1/4 (2115) ? FLUEVENT OUTLET \ ELECTRICAL INLET GAS INLET CONDENSATE.� _ = ,, 0 OUTLET r (EITRER SIDE) \ 5-1/2 15 (381) —4. I t (e G (140) 00� 26-1/2 S 27 [..._ (673) (686) 85-1/4 (2165) necr . SIDE VIEW 19-1/2 (495) 11 (279) 18-3/8 � (467) 1 (25) 1.451) 00 II i, III i��lll 20 1,, III (508) 1,1:11,„ I I /771... FORKLIFT SLOTS HORIZONTAL 5-1/2 I HORIZONTAL (Front, Bacnd) and SUPENINPPLYGR (140) RETURN OPENINGR Mower E(40) (Without Economizer) 29 (737) BACK VIEW Last Changed: TINA J. HANEY Prepared On: 2014-03-25 Phone: 972-497-6260 Lennox Industries Inc. - Product Submittal System ID: RTU 4 Package Model: LGH048H4E Description: PKGGE/4TON/CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL FOR OPTIONAL ECONOMIZER AND BAROMETRIC RELIEF DAMPERS (Down -Flow Applications) OPTIONAL OUTDOOR AIR HOOD -- (Furn<11eo vatI1 Emromizerl OPTIONAL BAROMETRIC RELIEF HCOD (Fumt;hed with Economizer) OUTDOOR AIR HOOD FOR ECONOMIZER (Furnished) i t-3'5 1203i 036 0uu 046 16.:it1 i1COI ono thu 072 SIDE VIEW BAROMETRIC RELIEF HOOD FOR ECONOMIZER (Furnished) Model No. A in. mm in. B mm in. C mm 036.048 19-1/4 4B9 13 330 11-3/4 298 060.072 23-1/4 591 17 432 15-3/4 400 Project: 3000409543 PetSmart #377 - Tukwila Quote: 4000487479 PetSmart #377 - Tukwila Page 6of23 Last Changed: TINA J. HANEY Prepared On: 2014-03-25 Phone: 972-497-6260 Lennox Industries Inc. - Product Submittal System ID: RTU 4 Package Model: LGH048H4E Description: PKGGE/4TON/CONFIGURABLE UNIT CLEARANCES - INCHES (MM) c OUTDOOR I. 'i 1' ,1 AIR HOOD Unit Clearance A B C D Top Clearance in. mm in. mm in. mm in. mm Service Clearance 48 1219 36 914 36 934 36 914 Unobstructed Clearance to Combustibles 36 914 1 25 1 25 1 25 Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE- Entire perimeter of unit base requires support when elevated above the mounting surface. Service Clearance - Required for removal of serviceable parts. Clearance to Combustibles - Required clearance to combustible material. Minimum Operation Clearance - Required clearance for proper unit operation. Project: 3000409543 PetSmart #377 - Tukwila Quote: 4000487479 PetSmart #377 - Tukwila Page 7 of 23 Last Changed: TINA J. HANEY Prepared On: 2014-03-25 Phone: 972-497-6260 Lennox Industries Inc. - Product Submittal MISCELLANEOUS MATERIALS 21W06 A335MT13AE1- SNSR, TEMP RH 94L60 COSNZNO7AE1- SENSOR, NONADJST TEMP 83W48 CIACURB40A YCD036-060A,C/TCD036-060C 83W55 C 1 ACURB4OB TCD102,1.20 A&B TO B 83W49 CIACURB4OB YCD075A,090A,B TO B COMSD Third Party CDI: EXISTING YCD075C Project: 3000409543 PetSmart #377 - Tukwila Quote: 4000487479 PetSmart #377 - Tukwila Page 23 of 23 Last Changed: TINA J. HANEY Prepared On: 2014-03-25 Phone: 972-497-6260 Lennox Industries Inc. - Product Submittal System ID: RTU 3,4,5 Package Model: LGH150S4M Description: PKGGE/12.5TON/CO iCJRAI LE4 "ht.I HEATING PERFORMANCE Heat Source H/E LowInput H/E LowOutput H/E HighInput H/E HighOutput System HeatOutput Natural Gas 117000 (Btuh) 93500 (Btuh) 180000 (Btuh) 144000 (Btuh) 144000 (Btuh) Gas Supply Connection H/E Heat Rise AFUE/ ThermalEff Number of Heating Stages Gas Supply Pressure 0.75 (in.) 26.7 (°F) 80 2 7 (in.WC) COOLING PERFORMANCE Refrigerant ARI EER ARI IEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Coil NetTotalCool Coil GrossSensCool Coil NetSensCool Environ Refrigerant Charge R-410A 11.0 13.1 12500 (W) 142600 (Btuh) 138000 (Btuh) 146900 (Btuh) 135265 (Btuh) 116051 (Btuh) 104416 (Btuh) 14 LBS. 0 OZ. Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 2 2 1.00 (in.) 95.0 (°F) 80.0 (°F) 67.0 (°F) 57.2 (°F) 57.2 (°F) 59.5 (°F) 58.1 (°F) 29.1 (lb/hr) 29.1 (lb/hr) SUPPLY FAN PERFORMANCE Supply Fan Total Air Flow Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM Motor Torque Pct ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range-Nom Voltage DIMENSIONS 5000 (cfm) 5000 (cfm) 0.80 (in.WC) 4.03 (hp) 5.00 (hp) MSAV Belt Drive 1131 (rpm) 900 (rpm) 1135 (rpm) 0 460V 3Ph 60 (Hz) 30.0 (amp) 35 (amp) 16.4 (amp) 27.0 (amp) +/- 10% TotalStaticPress Wet Coil Static Press Gas H/E Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 1.76 (in.WC) 0.33 (in.WC) 0.34 (in.WC) 0.29 (in.WC) 4 20.0 (in.) 25.0 (in.) 2.0 (in.) REVIEWED FOR CODE COiv PLIANCE SupplyFan FLA ' " E' 7.6 CondensingUnit LA 3.0 CondenserFan P er MAY 2 3 2014 820 City of Tukwila (amp) (amp) (W) Cabinet Width Cabinet Length Cabinet Height Total Weight 60.1 (in.) 101.3 (in.) 46.9 (in.) 1292 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 28.0 (in.) 24.0 (in.) 27.0 (in.) SOUND IOutdoor Sound Rating 88 (db) Project: 3000409543 PetSmart #377 - Tukwila Quote: 4000487479 PetSmart #377 - Tukwila Page 8 of 23 Last Changed: TINA J. HANEY Prepared On: 2014-03-25 Phone: 972-497-6260 RECEIVED CITY OF TUKWILA MAY 13 2014 PERMIT CENTER �ll�l-OLoO Lennox Industries Inc. - Product Submittal System ID: RTU 3,4,5 Package Model: LGH150S4M Description: PKGGE/12.5TON/CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Copeland Scroll Compressor Pre -charged Refrigeration System Expansion Valves High Capacity Driers Auto reset high & low pressure switch with strike 3 lockout feature in Prodigy unit controller Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Timed Off Control AGA-CGA Certified Units will operate cooling down to 0 degrees F (-17.7 degrees C) without additional controls. Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Aluminized Steel Inshot Burners Separate Compressor and Controls Compartment Advanced controls with Prodigy Control System Limited compressor warranty of 5 years Limited warranty on aluminized heat exchanger of 10 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED GLOBAL ECONOMIZER MULTI -STAGE AIR VOLUME HINGED ACCESS DOORS ENVIRON COIL SYSTEM MSAV BLOWER BYPASS DISCONNECT -WEATHERPROOF GFCI - FACTORY INSTALLED/FIELD WIRED BY ELECTRICIAN NOVAR LSE IMC INTEGRATION PHASE MONITOR RA SMOKE DETECTOR BLOWER BELT AUTO TENSIONER STANDARD CAP 2 IN MERV4 FILTER BAROMETRIC RELIEF DAMPERS Project: 3000409543 PetSmart #377 - Tukwila Quote: 4000487479 PetSmart #377 - Tukwila Page 9 of 23 Last Changed: TINA J. HANEY Prepared On: 2014-03-25 Phone: 972-497-6260 Lennox Industries Inc. - Product Submittal System ID: RTU 3,4,5 Package Model: LGH150S4M Description: PKGGE/12.5TON/CONFIGURABLE DIMENSIONS - INCHES (MM) Model No. CORNER WEIGHTS CENTER OF GRAVITY AA BB CC DO EE FF Base Max. Base Max. Base Max. Base Max. Base Max. Base Max. lbs. kg lbs. kg lbs. kg lbs. kg lbs. kg tbs. kg lbs. kg lbs. kg in. mm In. mm In. mm in. mm 092 293 133 338 153 263 119 295 134 286 130 316 143 326 148 370 168 46.5 1181 45.5 1156 24.5 622 25.5 648 102 294 134 340 154 265 120 297 135 288 131 318 144 328 149.372 169 46.5 1181 45.5 1156 24.5 622 25.5 648 120 306 139 349 158 275 125 305 138 295 134 326 148 334 152 382 173 46.5 1181 45.5 1156 24.5 622 25.5 648 150 316 143 359 163 284 129 314 142 304 138 393 178 345 157 393 178 46.5 1181 45.5 1156 24.5 622 25.5 648 Base Unit - The unit with NO INTERNAL OPTIONS, Max Unit - The unitwith AU. INTERNAL OPTIONS Installed. (Eoono n er, Standard Static Power Exhaust Fans, Contrds, etc.), Ones not Include axees+,Yies external 13 unit or h>;Th static p reer etelaust. 56118 (1476 60-1/8 (1527) = oGI END VIEW 46-7/8 (1 91) 43-36 (11021 • 3 1/2 (69) Project: 3000409543 PetSmart #377 - Tukwila Quote: 4000487479 PetSmart #377 - Tukwila Page 10 of 23 6118 (156)—� 61/8 (156) 1 24 in-3k (6/0) (273) S+SB BOTTOM SUPPLY (143) AR OPENING ( b7445 (1527) ) 27 BASE CENTER OF tr BOTTOM BOTTOM RETURN POti£R ENTRY AIR OPENING 5.12 (140) Oa. - EE .. FF It :' OW \ 1 DD .4-7 (178) CONDENSATE 34.7,E I,() BOTTOM 101.114 34A7J (25) ELECTRIC NLETS 34-7/6 ..— 028) 6 (2572) TOP VIEW 991/4 OPTIONAL OISCONNECT (2521) (FACTORY INSTALLED) 6 BB CC CONDENSATE DRAIN (FRONT) ▪ 39-7/8 ▪ (1013j - GAS SUPPLY / INLET FLUE OUTLET FORKU FT SLOTS (BOTH SIDES) LIFTING HOLES (FOR RIGGING) 101.114 (2572) SIDE VIEW (Hodzontal Openings) 46-7/8 (1 91) Last Changed: TINA J. HANEY Prepared On: 2014-03-25 Phone: 972-497-6260 Lennox Industries Inc. - Product Submittal System ID: RTU 3,4,5 Package Model: LGH150S4M Description: PKGGE/12.5TON/CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL 123f8 (543) OUTDOOR AIR HOOD (Fumished with Economizer or Outdoor Air Damper) EXHAUST AIR HOOD (Furnished, Field Installed) Project: 3000409543 PetSmart #377 - Tukwila Quote: 4000487479 PetSmart #377 - Tukwila Page 11 of 23 r >0 0. a .ii IIIII •IlII I I00 O O 00 Last Changed: TINA J. HANEY Prepared On: 2014-03-25 Phone: 972-497-6260 Lennox Industries Inc. - Product Submittal System ID: RTU 3,4,5 Package Model: LGH150S4M Description: PKGGE/12.5TON/CONFIGURABLE UNIT CLEARANCES - INCHES (MM) 1±: f Unit Clearance f Unit Clearance A B C D Top Clearance in. mm in. mm in. mm in. mm Service Clearance 60 1524 36 914 36 934 60 1524 Unobstructed Clearance to Combustibles 36 914 1 25 1 25 1 25 Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated al ove the mounting surface. Service Clearance - Required for removal of serviceable parts. Clearance to Combustibles - Required clearance to combustible material. Minimum Operation Clearance - Required clearance for proper unit operation. Project: 3000409543 PetSmart #377 - Tukwila Quote: 4000487479 PetSmart #377 - Tukwila Page 12 of 23 Last Changed: TINA J. HANEY Prepared On: 2014-03-25 Phone: 972-497-6260 1r Lennox Industries Inc. - Product Submittal System ID: RTU 6 Package Model: LGH072H4B HEATING PERFORMANCE Description: PKGGE/6TON/CONFIGURABL LE coo Heat Source H/E LowInput H/E LowOutput H/E Highlnput H/E HighOutput System HeatOutput Natural Gas 105000 (Btuh) 85500 (Btuh) 150000 (Btuh) 120000 (Btuh) 120000 (Btuh) Gas Supply Connection H/E Heat Rise AFUE/ ThermalEff Number of Heating Stages Gas Supply Pressure PA 0.50 (in.) 46.3 (°F) 80 2 7 (in.WC) COOLING PERFORMANCE Refrigerant ARI EER ARI IEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Coil NetTotalCool Coil GrossSensCool Coil NetSensCool Tube/Fin Humiditrol Refrigerant Charge R-410A 12.0 13.5 6000 (W) 73500 (Btuh) 72000 (Btuh) 77200 (Btuh) 73400 (Btuh) 57900 (Btuh) 54100 (Btuh) 16 LBS. 5 OZ. SUPPLY FAN PERFORMANCE Supply Fan Total Air Flow Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM Motor Torque Pct 2400 (cfin) 2400 (cfin) 0.80 (in.WC) 1.19 (hp) 2.00 (hp) CAV Belt Drive 887 (rpm) 798 (rpm) 1105 (rpm) 0 Number Compressors Number of Cooling Stages Condensate Drain Size 1 1 1.00 (in.) Cooling OutdoorDB __. 95.0 (°F) Cooling Mixed ►B REVIEWED FOR 8( .0 (°F) Cooling Mixed ODE COMPLIANC #.0 (°F) Coil Discharge [+ :g.2 (°F) Coil Discharge : APPROVED 5 .2 (°F) Unit Discharge 5 .8 (°F) Unit Discharge" : MAY 2 3 2014 5 .8 (°F) Coil MoistureR rnoval 1 .2 (lb/hr) System MoistR mova 1 •.2 (lb/hr) cl T:t-",:1 pi ill fliNr, n!\/iS W)N F 10 (in.WC) Press 0.13 (in.WC) 0.08 (in.WC) Press 0.04 (in.WC) Press 0.05 (in.WC) 4 20.0 (in.) 20.0 (in.) 2.0 (in.) TotalStaticPres Wet Coil Static Gas H/E Static Press Humiditrol Static Economizer Static Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range-Nom Voltage 460V 3Ph 60 (Hz) 15.0 (amp) 20 (amp) 9.7 (amp) 14.5 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 3.4 (amp) 1.4 (amp) 410 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 47.0 (in.) 85.3 (in.) 46.9 (in.) 953 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 18.0 (in.) 29.0 (in.) 11.0 (in.) SOUND Outdoor Sound Rating 82 (db) Project: 3000409543 PetSmart #377 - Tukwila Quote: 4000487479 PetSmart #377 - Tukwila Page 13 of 23 Last Changed: TINA J. HANEY Prepared On: 2014-03-25 Phone: 972-497-6260 RECEIVED CITY OF TUKWILA MAY 13 2014 PERMIT CENTER Lennox Industries Inc. - Product Submittal System ID: RTU 6 Package Model: LGH072H4B Description: PKGGE/6TON/CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Copeland Scroll Compressor Pre -charged Refrigeration System Expansion Valves High Capacity Driers Auto reset high & low pressure switch with strike 3 lockout feature in Prodigy unit controller Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Timed Off Control AGA-CGA Certified Units will operate cooling down to 0 degrees F (-17.7 degrees C) without additional controls. Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Aluminized Steel Inshot Burners Separate Compressor and Controls Compartment Advanced controls with Prodigy Control System Limited warranty on aluminized heat exchanger of 10 years Limited compressor warranty of 5 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED GLOBAL ECONOMIZER CONSTANT AIR VOLUME HINGED ACCESS DOORS TUBE AND FIN COIL SYSTEM DISCONNECT - WEATHERPROOF GFCI - FACTORY INSTALLED/FIELD WIRED BY ELECTRICIAN HUMIDITROL NOVAR LSE IMC INTEGRATION RA SMOKE DETECTOR BLOWER BELT AUTO TENSIONER STANDARD CAP 2 IN MERV4 FILTER BAROMETRIC RELIEF DAMPERS Project: 3000409543 PetSmart #377 - Tukwila Quote: 4000487479 PetSmart #377 - Tukwila Page 14 of 23 Last Changed: TINA J. HANEY Prepared On: 2014-03-25 Phone: 972-497-6260 Lennox Industries Inc. - Product Submittal System ID: RTU 6 Package Model: LGH072H4B Description: PKGGE/6TON/CONFIGURABLE DIMENSIONS - INCHES (MM) CORNER WEIGHTS CENTER OF GRAVITY Model No. AA BB CC DD EE FF GG HH Ibs. kg Ibs. kg Ibs. kg Ibs. kg in. mm in. mm in. mm in. mm LGH036 Std. Unit 98 45 119 54 192 87 158 72 38.5 978 18 457 29 737 46.75 1187 LGH036 Max. Unit 132 60 149 68 241 109 213 97 40 1016 18 457 29 737 45.25 1149 LGH048 Std. Unit 104 47 126 57 202 92 167 76 38.5 978 18 457 29 737 46.75 1187 LGH048 Max. Unit 140 64 158 72 255 116 225 102 40 1016 18 457 29 737 45.25 1149 LGH060 Std. Unit 118 54 144 65 232 105 191 87 38.5 978 18 457 29 737 46.75 1187 LGH060 Max. Unit 159 72 179 82 289 131 256 116 40 1016 18 457 29 737 45.25 1149 LGH072 Std. Unit 132 60 160 73 258 117 212 96 38.5 978 18 457 29 737 46.75 1187 LGH072 Max. Unit 167 76 189 86 305 138 269 122 40 1016 18 457 29 737 45.25 1149 Std. Unit - The unit with NO OPTIONS. Max. Unit - The unit with ALL OPTIONS Installed. (Economizer. etc.) I (1143)� j00 1 1 (25) I I001 47(1192) BASE END VIEW Project: 3000409543 PetSmart #377 - Tukwila Quote: 4000487479 PetSmart #377 - Tukwila Page 15 of 23 5.518 11 16-1/4 18 (143 (279) (413) (457) 47 (1192) BASE 7 ( 78) 29 (737) BOTTOM RETURN R OPENING 20 BOTTOM (508) SUPPLY"' OPENING CENTER T i OF I GRAVITY FF 6.5/8 (168 25-3r4 (654) 9-1/2 (241) 92. 3-1 LIFTING HOLE (For rigging) DD 26-1/2 (673) BB C EE C BOTTOM BOTTOM POWER ENTRY CONDENSATE OUTLET 3 X 8 (76 X 203) TOP VIEW (Base) c v 83.1/4 (2115) J FLUENENT OUTLET\ ELECTRICAL INLET / GAS INLET CONDENSATE --- _ = 0 OUTLET (EITHER SIDE) \ 5-1/2 15 (381) —'► '2(89) I 0 C O I (140) ( 1 l4 1 ■ 001 27 —r (673) () 85-1/4(2165) RASE r SIDE VIEW 11 1 (25) 19-112 18.318 f (279) 2 (51) (495) (467) I r— II Ili !ill': III I 1 1 I;�L 11111 111111 I I L1. _:18) i 29 (737) 00 _ I j7I /00( FORKLIFT SLOTS HORIZONTAL HORIZONTAL (Front. Back and SUPPLY AIR 5- RETURN AIR S-1r Biower End)OPENING ( ) OPENING (140) (Without Economizer) BACK VIEW Last Changed: TINA J. HANEY Prepared On: 2014-03-25 Phone: 972-497-6260 Lennox Industries Inc. - Product Submittal System ID: RTU 6 Package Model: LGH072H4B Description: PKGGE/6TON/CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL FOR OPTIONAL ECONOMIZER AND BAROMETRIC RELIEF DAMPERS (Down -Flow Applications) _I l_ 11-3'41203i 036 thm 04E 15.: /4 (GM 050 iMu 072 OPTI ONAL OUTDOOR AIR HOOD (Fum51e0 oath Emromizeri OPTIONAL BAROMETRIC RELIEF HCOD Fumi;hec with Ecoromize) OUTDOOR AIR HOOD FOR ECONOMIZER (Furnished) SIDE VIEW BAROMETRIC RELIEF HOOD FOR ECONOMIZER Furnished) Model No. in. A mm in. B mm C in. mm 036.048 19-1/4 459 13 330 113/4 298 060, 072 23-1/4 591 17 432 15-3/4 400 Project: 3000409543 PetSmart #377 - Tukwila Quote: 4000487479 PetSmart #377 - Tukwila Page 16 of 23 Last Changed: TINA J. HANEY Prepared On: 2014-03-25 Phone: 972-497-6260 Lennox Industries Inc. - Product Submittal System ID: RTU 6 Package Model: LGH072H4B Description: PKGGE/6TON/CONFIGURABLE UNIT CLEARANCES - INCHES (MM) OUTDOOR %'iii AIR HOOD ,li i t Unit Clearance A B C D Top Clearance in. mm in. mm in. mm in. mm Service Clearance 48 1219 36 914 36 934 36 914 Unobstructed Clearance to Combustibles 36 914 1 25 1 25 1 25 Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. ' Service Clearance - Required for removal of serviceable parts. Clearance to Combustibles - Required clearance to combustible material. Minimum Operation Clearance - Required clearance for proper unit operation. Project: 3000409543 PetSmart #377 - Tukwila Quote: 4000487479 PetSmart #377 - Tukwila Page 17 of 23 Last Changed: TINA J. HANEY Prepared On: 2014-03-25 Phone: 972-497-6260 Lennox Industries Inc. - Product Submittal System ID: RTU 7 Package Model: LGH092H4B Description: PKGGE/7.5TON/CON1 LPrn V HEATING PERFORMANCE Heat Source WE Lowlnput H/E LowOutput H/E Highlnput H/E HighOutput System HeatOutput Natural Gas 117000 (Btuh) 93500 (Btuh) 180000 (Btuh) 144000 (Btuh) 144000 (Btuh) Gas Supply Conne&on H/E Heat Rise AFUE/ ThermalEff Number of Heating Stages Gas Supply Pressure 0.75 (in.) 44.4 (°F) 80 2 7 (in.WC) COOLING PERFORMANCE Refrigerant ARI EER ARI IEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Coil NetTotalCool Coil GrossSensCool Coil NetSensCool Environ Refrigerant Charge R-410A 12.5 12.9 7500 (W) 93000 (Btuh) 90000 (Btuh) 93000 (Btuh) 88361 (Btuh) 67890 (Btuh) 63251 (Btuh) 15 LBS. 0 OZ. SUPPLY FAN PERFORMANCE Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit Dischargpl�._„„w__, 2 2 1.00 (in.) 95.0 (°F) 80.0 (°F) 67.0 (°F) 57.7 (°F) 56.6 (°F) 59.3 (°F) Unit Dischar wBREVIEVITED FOR 57.2 (°F) Coil Moisture 23.7 (lb/hr) System Moist em E COMPLIANCE 23.7 (lb/hr) Y n ee- r raga t3 t� Supply Fan Total Air Flow Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM Motor Torque Pct 3000 (cfm) 3000 (cfin) 0.80 (in.WC) 1.46 (hp) 2.00 (hp) CAV Belt Drive 864 (rpm) 590 (rpm) 890 (rpm) 0 TotalStaticPrE Wet Coil Stat Gas H/E Stati Economizer Air Filter Qt Air Filter Le Air Filter WI' ?h ss MAY 2 3 2014 l.15 (in.WC) c Press b.10 (in.WC) Press 1.12 (in.WC) taticPuss 10.13 (in.WC) uty of Tukwila oh UILDING DIVISION �0.0 (in.) Air Filter Thickness •f25.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range-Nom Voltage 460V 3Ph 60 (Hz) 20.0 (amp) 25 (amp) 12.2 (amp) 18.2 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 3.4 (amp) 2.6 (amp) 725 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 60.1 (in.) 101.3 (in.) 46.9 (in.) 1200 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 28.0 (in.) 24.0 (in.) 27.0 (in.) SOUND Outdoor Sound Rating 88 (db) Project: 3000409543 PetSmart #377 - Tukwila Quote: 4000487479 PetSmart #377 - Tukwila Page 18 of 23 Last Changed: TINA J. HANEY Prepared On: 2014-03-25 Phone: 972-497-6260 RECEIVED CITY OF TUKWILA MAY 132Ci 104 TV' t Lennox Industries Inc. - Product Submittal System ID: RTU 7 Package Model: LGH092H4B Description: PKGGE/7.5TON/CONFIGURABLE SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Copeland Scroll Compressor Pre -charged Refrigeration System Expansion Valves High Capacity Driers Auto reset high & low pressure switch with strike 3 lockout feature in Prodigy unit controller Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Crankcase Heater Timed Off Control AGA-CGA Certified Units will operate cooling down to 0 degrees F (-17.7 degrees C) without additional controls. Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Aluminized Steel Inshot Burners Separate Compressor and Controls Compartment Advanced controls with Prodigy Control System Limited compressor warranty of 5 years Limited warranty on aluminized heat exchanger of 10 years Limited warranty on Prodigy Unit Controller of 3 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED GLOBAL ECONOMIZER CONSTANT AIR VOLUME HINGED ACCESS DOORS ENVIRON COIL SYSTEM DISCONNECT - WEATHERPROOF GFCI - FACTORY INSTALLED/FIELD WIRED BY ELECTRICIAN NOVAR LSE IMC INTEGRATION RA SMOKE DETECTOR BLOWER BELT AUTO TENSIONER STANDARD CAP 2 IN MERV4 FILTER BAROMETRIC RELIEF DAMPERS Project: 3000409543 PetSmart #377 - Tukwila Quote: 4000487479 PetSmart #377 - Tukwila Page 19 of 23 Last Changed: TINA J. HANEY Prepared On: 2014-03-25 Phone: 972-497-6260 Lennox Industries Inc. - Product Submittal System ID: RTU 7 Package Model: LGH092H4B Description: PKGGE/7.5TON/CONFIGURABLE DIMENSIONS - INCHES (MM) Model No. CORNER WEIGHTS CENTER OF GRAVITY AA BB CC DD EE FF Base Max. Base Max. Base Max. Base Max. Base Max. Base Max. Ibs. kg lbs. kg Ibs. kg Ibs. kg Ibs. kg lbs. kg lbs. kg lbs. kg in. mm in. mm In. mm in. mm 092 293 133 338 153 263 119 295 134 286.130 316 143 326 148 370 168 46.5 1181 45.5 1156 24.5 622 25.5 648 102 294 134 340 154 265 120 297 135 288 131 318 144 328 149 372 169 46.5 1181 45.5 1156 24.5 622 25.5 648 120 306 139 349 158 275 125 305 138 295 134 326 148 334 152 382 173 46.5 1181 45.5 1156 24.5 622 25.5 648 150 316 143 359 163 284 129 314 142 304 138 393 178 345 157 393 178 46.5 1181 45.5 1156 24.5 622 25.5 648 Base Unit - The ant 111111 NO INTERNAL OPTIONS. Max. Unit - The unit with ALL INTERNAL OPTIONS hslalkd. (Ecwrom¢e[ Standard Static Power Exhaust Fans, Conuds, etc.). Does not rndude accessories external lo w4t0r high $tatiC power Wraps*. 56-118 (1476) 46-71) (1 91) 43-30 (1102) I 0 0 = 99-1)8 (1527) = 001 3-U2 (89) END VIEW Project: 3000409543 PetSmart #377 - Tukwila Quote: 4000487479 PetSmart #377 - Tukwila Page 20 of 23 6-1(8 (156) 5-58 (143) BOTTOM SUPPLY ARO'E!4?G 61)8_0 (156) 27 ) 24 610) 10-3M (273) ■ 23 20 (711) (508) 60.1)8 (1527) I CENTER OF BASE �/' GRAYItY BOTTOM I BOTTOM RETURN PONERENTRY AIR OPENINCs (! 5-171 (140) Da. + EE - I AIR 7 (178) } OD BOTTOM CONDENSATE (25) ELECTRIC INLETS FF efir8 8 168) 7 (178) 34-7/i MS) 101-1)4 Rd4P (2572) TOP VIEW 99-1/4 14 OPTIONAL DISCONNECT ( ) (FACTORY INSTALLED) 34-7M) 411-() L 39-7/8 (1013) FORKLIFT SLOTS (80T11 SIDES) LIFTING HOLES (FOR RIGGING) 101-114 (2572) BB SIDE VIEW SIDE VIEW (Horizontal Openings) CC 46-7/8 (1191) Last Changed: TINA J. HANEY Prepared On: 2014-03-25 Phone: 972-497-6260 Lennox Industries Inc. - Product Submittal System ID: RTU 7 Package Model: LGH092H4B Description: PKGGE/7.5TON/CONFIGURABLE ACCESSORY DIMENSIONS - INCHES (MM) OUTDOOR AIR HOOD DETAIL 21-3l8 (543) OUTDOOR AIR HOOD (Fumished with Economizer or Outdoor Air Damper) EXHAUST AIR HOOD (Furnished, Field Installed) Project: 3000409543 PetSmart #377 - Tukwila Quote: 4000487479 PetSmart #377 - Tukwila Page 21 of 23 r > 0 -Too O 11 ,I II I,IIieee ,, O O 00 Last Changed: TINA J. HANEY Prepared On: 2014-03-25 Phone: 972-497-6260 Lennox Industries Inc. - Product Submittal System ID: RTU 7 Package Model: LGH092H4B Description: PKGGE/7.5TON/CONFIGURABLE UNIT CLEARANCES - INCHES (MM) OPTIONAL / OUTDOOR AIR HOOD A/ , ///// -_ ////// y Unit Clearance A B C D Top Clearance in. mm in. mm in. mm in. mm Service Clearance 60 1524 36 914 36 934 60 1524 Unobstructed Clearance to Combustibles 36 914 1 25 1 25 1 25 Minimum Operation Clearance 36 914 36 914 36 914 36 914 NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. ' Service Clearance - Required for removal of serviceable parts. Clearance to Combustibles - Required clearance to combustible material. Minimum Operation Clearance - Required clearance tor proper unit operation. Project: 3000409543 PetSmart #377 - Tukwila Quote: 4000487479 PetSmart #377 - Tukwila Page 22 of 23 Last Changed: TINA J. HANEY Prepared On: 2014-03-25 Phone: 972-497-6260 City of Tukwila Department of Community Development 10/1/2014 Jim Haggerton, Mayor Jack Pace, Director DAVE ZIGWEID 5009 PACIFIC HY E, STE 9 FIFE, WA 98424 RE: Permit No. M14-0100 PETSMART 17585 SOUTHCENTER PY Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/24/2014. Based on the above, you are hereby advised to: 1) Ca11 the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/24/2014, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M 14-0100 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0100 DATE: 05/13/2014 PROJECT NAME: PETSMART SITE ADDRESS: 17585 SOUTHCENTER PY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: P\g/ 4'N Building Division Public Works r,YY' AV/G Fire Prevention Structural Planning Division Permit Coordinator n n PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 05/15/14 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 06/12/14 Approved Approved with Conditions n Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 GSC MECHANICAL LLC Page 1 of 2 Washington State !Deparliiuent of Lab©r & Industries GSC MECHANICAL LLC Owner or tradesperson HUNTINGTON, BETTY Principals HUNTINGTON, BETTY, MANAGER MCCLLOUGH, LEARY H, AGENT Doing business as GSC MECHANICAL LLC WA UBI No. 603 033 088 5009 PACIFIC HWY E STE #9 TACOMA, WA 98424 253-235-5692 PIERCE County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor License specialties HVAC/RFRG License no. GSCMEML866BB Effective — expiration 01/02/2014— 01/02/2016 Designated administrator Savage, Jason R License type Master Electrician Bond Westchester Surp Lines Ins Co Bond account no. K08945329 Received by L&I 01/02/2014 Insurance No insurance accounts during the previous 6 year period. Savings No savings accounts during the previous 6 year period. License Violations Active. Meets current requirements. Active. Meets current requirements. License no. SAVAGJR875BQ $4, 000.00 Effective date 01/02/2014 No license violations during the previous 6 year period. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603033088&LIC=GSCMEML866BB&SAW= 05/28/2014 V-sqs t-)w-b -* 3-2 ? FILE en "IV 33 48 Mgr f— 29 9/18' —� 147116" L. - 79 3!4" 2" TYP 22 15/18" rs Notes; 1. 1,5" ADDED TO OLD CURB 0.0 2. MATERIAL: 18 ga. GALVANIZED STEEL 3, GASKET PROVIDED WITH CURB 4. INSULATION: 1" 1 112 LB DENSITY 78 3/4" rw EN/IONEO ASOTOIERENCEOP6'R ANSI WAWA Ji Attn: Tag: 83W48 Approval: 21/4" 43` 40 3/4' EXISTING CURB LAYOUT 49 11/18" 34 7116" 14 1Q" r T j-+21/4' CURB SHOWN IS CDI STANDARD CONFIGURATION CDI RESERVES THE RIGHT TO CHANGE LAYOUT WITHOUT NOTIFICATION. IF CURB IS NEEDED IN A DIFFERENT CONFIGURATION CD1 MUST BE NOTIFIED PRIOR TO PLACING AN ORDER. SUPPLY REV, REVISIONS DESCRIPTION DATE APPROVED INITIAL DWG 6714/11 SRP 2 updoled lop brace size I I/17/11 00 RETURN AIR SUPPLY AIR REVIE \ CODE COIUIPLI�� �' Ve� APPROVED MAY 2 3 2014 City of Tukwila BUILDING DIVISION 77 114" 41 112" —'--1 44 1/2" COI Model Number Existing Unit New Unit Tonnage Supply Pressure Drop Return Pressure Onop 14030220E0 YCD+W00036,000A TlEnergencd Landmarky A Box 3 4 0.008 0.014. 0.005 0008 5 0.022 0.014 6 0.032 0.020 csas' :DTlws.I 107.44 AP9SOV.LL3 OATS VERIFY LUSTING CURD DO VERIFYSUPPLYAND RETURN OPENING NOTE ANY CHANGES CALL WITH ANY QUEsnONS FAX BACK IF DRAWING IB. 1,1y11 sxm, Ep4C'4.af 7uea8ay. July 19. 3011 0:30.23 AM 83W48 TVE 17560 TYLER ST NW CCDIBLK RIVER, NN66390 tr.(783)311.7790 I 780191.7851 CITY OF TUKWILA MAY 1 3 2014 PERMIT CENTER sta B3W4$.1.3000 2060 7 K.. 125 I wwr. 1 w 3 M1Lk Otoo \3.---Src\ I3))')U \J \ 319/16" 69 5/16" 399/16" 31 1/16" - 95 3/8' 90 7/16' Notes: 1. 1.8" ADDED TO OLD CURB OD 2. MATERIAL: 16 ga. GALVANIZED STEEL 3. GASKET PROVIDED WITH CURB 4. INSULATION: 1" 1 112 LB DENSITY 23 9/16" 011.6,0115 AIDTOLERP.NCEO PEN ANSIV1AAa1ISS Attn: Tag: 83W55 Approval: 21/4' 56 7/8" 59 1 /8" EXISTING CURB LAYOUT 57 5/16" 32 13/16" --� 201 4 2tt4° RETURN CURB SHOWN IS CDI STANDARD CONFIGURATION CDI RESERVES THE RIGHT TO CHANGE LAYOUT WITHOUT NOTIFICATION. IF CURB IS NEEDED IN A DIFFERENT CONFIGURATION CDI MUST BE NOTIFIED PRIOR TO PLACING AN ORDER. 88 1 5/16" REVISIONS REV. DESCRIPTION DATE APPROVED INRIAL DWG. SAME AS 1-3310.2035 REV2 { 6/27/11 SRP 2 1/4" 491 /4' SUPPLY } 54 1/4" 60 5/8" CDf Model Number Existing Unit New Unit Tonnage Supply Pressure Drop Return Pressure Drop 1.3010-2085 TCD102ASB. TCD120A&B HIGH HEAT UT/K/ENERGENCE B BOX 7.5 0.0094 0.0333 10 12.5 0.0169 0.0276 0.0592 0.0927 CYiRawGNIMTI APPROVALS 5555 215.25 'VERIFY EXISTING CURB OD 'VERIFY SUPPLY AND RETURN OPENINOS NOTE ANY CHANGES CALL WITH ANY QUESTIONS 'FAX BACK IF DRAWING IS OK AS 15. _. cpir'55 Tuesday, July 18.2011 8:20�. 54 NA ], 17560 TYLER ST NW C1) 1 31091 T790 N 55330 (763/391.7851 83W55 Rama., tee 83W55-1-3010-2085 *cm, 125 usr: 1 of 3 RECEIVED CITY OF TUKWILA MAY 1 3 2014 44-€9 33 13/16' 48 11/16' 29 9/16" 14 7116" 79 314' Notes: 1. 1.5' ADDEO-TO OLD CURB 0.D 2. MATERIAL: 18 ga GALVANIZED STEEL 3. GASKET PROVIDED WITH CURB 4.INSULATION: 1" 1 1/2 LB DENSITY 82 3/4" 10 DOSCNSIONED AND TOtatENCEO PER ANSI Vr4.QW11t Attn: Tag: Approval: EXISTING .CURB LAYOUT CURB SHOWN IS CDI STANDARD CONFIGURATION CDI RESERVES THE RIGHT TO CHANGE LAYOUT WITHOUT NOTIFICATION. IF CURB IS NEEDED IN A DIFFERENT CONFIGURATION CDI MUST BE NOTIFIED PRIOR TO PLACING AN ORDER. REVISIONS REV, DESCR/RTION DATE APPROVED 6/2,1/2004 OURAraro$r ROSS APPROVALS RASP 210.39 decem 'VERIFY EXu 15iO ...will 00 'VERIFY SUIKY ANO RETURN OFEMW6s NOTE ANY CHANGES CAU. 1wT6 ANY QUESTIONS FAX 6AER IF ORAWIN6 IS OK AS IS Tueadxv. December 30,200 16:5014 AM ""` 1-3005-2060 QUOTE #: am 17560 TYLER 5T NW CDI 56 )RNER,SON558#0 1-3005-2060 V•voodto vs! T iRIECEIttdD CITY OF TUKWILA MAY 13 2014 PERMIT CENTER \-y,cc—,>; —3-?-7 \)\. 31 9/16" 66 13/16" 37 1/16" +-28 9/16" —+- 1' 95 3/8" �2"TYP Notes: 1. 1.5" ADDED TO OLD CURB 0. D 2, MATERIAL: 18 ga. GALVANIZED STEEL 3. GASKET PROVIDED WITH CURB 4. INSULATION: 1" 1 1/2 LB DENSITY 82 3/4" DrNEH9DNED AND TOLERENCFDPEA ANSI Y}Sgy.1$1 Attn: Tag: 83W49 Approval: 23 9/18' 45' EXISTING CURB LAYOUT RETURN, CURB SHOWN IS CDI STANDARD CONFIGURATION CDI RESERVES THE RIGHT TO CHANGE LAYOUT WITHOUT NOTIFICATION. IF CURB IS NEEDED IN A DIFFERENT CONFIGURATION CDI MUST BE NOTIFIED PRIOR TO PLACING AN ORDER. 81 1/4" 2 1/4" 38" REV. REVISIONS DESCRIPTION INITIAL DRAWING. SAME AS 1.3305.20E5 REV2 DATE APPROVED 6114/11 SRP 2 updated lop txaces sae 11/17/11 00 54 1/4" 471/2` 14" -WI Uo PteMer Erie' New Uti1 to ris0e Stipp,/ Pressure PAlum seeswe OTW Crap v'T:K E:Inrlwta D 6 W Ip" 110 rse 3033 0360 0.133 6.0$5 0526 GYRO Vn<IGw1/106-1P APPA0YAL8 EATR 168.56 VERIFY SLIPPLY AND RETURN OPEN1Na5, NOTE ANY CHANGES CALL WITH ANY QUESTIONS FAX BACK IF DRAWING IS OH A515 ,,,_, Thsrsday, NDva0558111, 201 CDI 1 11;24311 AM 17860 TYLER-ST NW ELK RIVER MN 55330 (7831391.7790 /1$31791a651 Tae: � Pwr 83W49 less I83W4&1-3005.2085 7 f s1us: 125 s sex 1 Te 3 Ei%tVED CITY OF TUKWILA MAY 13 2014 PERMIT CENTFP