HomeMy WebLinkAboutPermit M14-0101 - GAMEFLY - DUCTLESS SPLIT SYSTEMGAMEFLY 12860 INTERURBAN AVE S M14-0101 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2716000010 12860 INTERURBAN AVE S BLDG 1 Project Name: GAMEFLY Permit Number: M14-0101 Issue Date: 5/27/2014 Permit Expires On: 11/23/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: EPROPERTY TAX INC DEPT #207 PO BOX 4900 , SCOTTSDALE, WA, 85261 JOEL SCHUPPERT 6426 18TH ST E , FIFE, WA, 98424 MECHANICAL & CONTROL SRVCS INC 301 PORTER WAY , MILTON, WA, 98354 MECHACS962BT Phone: (253) 926-9777 Phone: (253) 926-9777 Expiration Date: 2/26/2016 DESCRIPTION OF WORK: INSTALL 1 NEW 1.5 TON DUCTLESS SPLIT SYSTEM FOR A NEW SERVER ROOM. Valuation of Work: $3,450.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $246.42 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer Distric: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Signature: (461 Date: 1 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development -rmit and .gee, to the conditions attached to this permit. . Signatur Date: S_Z 7 - 20 i(1 Print Na 3-66C_ �GH(A.Ped 1 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***MECHANICAL PERMIT CONDITIONS*** 2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. 1�IL./dl0/ Date Application Accepted: Date Application Expires: o s//3// „/,3/i (For office use only) • MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: King Co Assessor's Tax No.: 12860 Interurban Avenue Tukwila Tenant Name: Game Fly PROPERTY OWNER Name: EPROPERTY Tax Inc Dept. 207130709 Address: PO Box 4900 City: Scottsdale State: AZ Zip: 85261 CONTACT PERSON — person receiving all project communication Name: Joel Schuppert Address: 6426 18th st east City: Fife State: Wa Zip: 98424 Phone: (253) 926-9777 Fax: (253) 926-9222 Email: joels@groupmcs.com 2716000010 Suite Number: 12860 Floor: 1 New Tenant: m Yes ❑..No MECHANICAL CONTRACTOR INFORMATION Company Name: Mechanical & Control Services, Inc. Address: 6426 18th street east City: Fife State: Wa Zip: 98424 Phone: (253) 926-9777 Fax: (253) 926-9222 Contr Reg No.: MECHACS962BT Exp Date: 02/26/2016 Tukwila Business License No.: ql AL).-. 06 tl is Valuation of project (contractor's bid price): $ 3,450 Describe the scope of work in detail: Install 1 new 1.5 Ton Ductless Split System For a New Server Room. Use: Residential: New ❑ Commercial: New Replacement Replacement Fuel Type: Electric Q] Gas ❑ Other: H:Wpplications\Fonns-Applications On Line\201 I Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 1 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 'VNER OR AUTHORIZED AGENT: Signatur Print Name: -Joel Schuppert Mailing Address: 6426 18th street east H:Wpplications\Fomn-Applications On Line\201 I ApplicationsWechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Day Telephone: Fife City Date: 05/12/2014 (253) 926-9777 WA 98424 State Zip Page 2 of 2 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431-2451 (�1'c7/ 0 it (206) 431-3670, Project:_ (___ A,'),\ I J v Type off Inspection: ,'tA :' (.,/,-, r . ,,v /1 \ / Address: / 12 5 0 0 ..:iA 0,i- J r a/) Date Called: Special Instructions: fi, \ l L)C7 ! 6D K ' �, .1, ,, Date Wanted: • V' ' ' L" )4 ca.rri' p.m. Requester Phone No: n rA Approved per applicable codes. t� Corrections required prior to approval. COMMENTS: A / Inspectors / o - _ �ltrtn.0 j,� REINSPECTION FEE RE UIRED. Prior to next inspection, fee must/be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: / —t /_ Ld J INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 ,/4/i/'0%i Project: /r�a€ r�-y Typ of Inspection: • /, h - , /%.1 ,, 7 / fin (/q� AdSpecial Date Called: Instructions: Date Wanted: ..—/ , J `� 1 p.m. Requester: Phone No: 'Approved per applicable codes. Corrections required prior to approval. COMMENTS: A l)W6`)<i')- ,,vn - '-1.,u761/tod _ 1 _7( ?� n1.SP -r-, t /-( ,a /) Ins eCtot: ,\ L 3_ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be jaid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT I QUANTITY PermitTRAK PAID $246.42 M14-0101 Address: 12860 INTERURBAN AVE S BLDG 1 Apn: 2716000010 $246.42 MECHANICAL $236.94 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $157.05 PLAN CHECK FEE R000.322.102.00.00 $47.39 TECHNOLOGY FEE $9.48 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2110 R000.322.900.04.00 $9.48 $246.42 Date Paid: Tuesday, May 13, 2014 Paid By: MECHANICAL & CONTROL SERVICES Pay Method: CHECK 26714 Printed: Tuesday, May 13, 2014 12:01 PM 1 of 1 CPWSYSTEMS FILE COIP VDAIKIN AQ® Submittal D absolute comfort Project Name: Game Fly Tukwila Location: Engineer: Submitted to: Submitted by: Reference: Performance Indoor Unit Model No: Outdoor Unit Model No: Rated Cooling Capacity (Btu/hr): Sensible Capacity (Btu/hr): Max/Min Cooling Capacity (Btu/hr/kW): Cooling Input Power (kW): SEER: Rated Heating Capacity (Btu/hr): Max/Min Heating Capacity (Btu/hr/kW): Heating Input Power (kW): Heating COP (Btu/hr/Btu/hr): HSPF: FAQ18PVJU RZR18PVJU 18000 13700 Itabook/databook 1.607 18.6 N/A ►tabook/databook N/A N/A N/A Indoor Unit Details Power Supply (V/Hz/Ph:) Power Supply Connections: Min Circuit Amps MCA (A): Max OvercurrentAmps MFA (A): Dimensions (HxWxD): Panel (HxWxD): Net Weight (lbs): Weight with Panel (lbs): Condensing Unit Details Power Supply (V/Hz/Ph): Power Supply Connections: Min. Circuit Amps MCA (A): Max. Overcurrent Amps MFA (A): Max. Starting Current MSC(A): Rated Load Amps RLA (A): Dimensions (HxWxD): Net Weight (lbs): System Details Refrigerant Type: Holding Refrigerant Charge (lbs): Additional Charge (oz/ft): Pre -charge Piping (Length ft): Max. Pipe Length (Total ft): 208-230/60/1 ph L1, L2, Ground 0.4 15 11-3/8x41-3/8x9 N/A 31 208-230/60/1 ph L1, L2, Ground 16.5 20 7.1 30-5/16x35-7/16x12-5/8 150 R-410A 5.1 0.036Ibs/ft 164 ft Approval: Date: 5-12-14 Construction: Unit #: FC-1/HP-1 Drawing #: Indoor Unit Type: Condensing Unit Type: Rated Cooling Conditions eF VIEWEDOR CODE COMPLIANCE APPROVED MAY 21 2014 of Tukwila BUILDING DIVISION Wall Mounted SkyAir Cool Only Indoor: 80°F DB/67°F WB Outdoor: 95°F DB/75°F WB Rated Heating Conditions Indoor: N/A Outdoor: N/A Rated Piping Length(ft) Rated Height Separation(ft) 25 0 Airflow Rate (CFM wet coil) Moisture Removal (pt/h): Gas Pipe Connection (inch): Liquid Pipe Connection (inch): Condensate Connection (inch): Sound Pressure Level (dBA): Sound Power Level (dBA): Static Pressure Rated/Max (inWg) Compressor Type: Capacity Control Range (%): Airflow Rate (CFM): Gas Pipe Connection (inch): Liquid Pipe Connection (inch): Sound Pressure Level (dBA): Sound Power Level (dBA): Max. Pipe Length (Vertical ft): Cooling Operation Range (F): Cooling Range w/Baffle (F): Heating Operation Range (F): Heating Range w/Baffle (`F): VI I 0 ( 0 I 500//400 5/8 3/8 1 43 0/0/0 Inverter 35 - 100 1835 5/8 3/8 49 98 ft 23 - 115 RiIVED CITY OfurUKWILA MAY 1 3 2014 PERMIT CENTER Daikin AC (Americas), Inc., 1645 Wallace Drive - Suite 110, Carrollton, TX 75006 Page 1 of 4 Daikin AC TRL Generated Submittal Data www.daikinac.com )Daikin's products are subject to continuous improvements. Dalin reserves the right to modify product design, spsalicalions and information in this data sheet without notice and without incurring any obligations) VDAIKIN AC° absolute comfort Project Name: Game Fly Tukwila Location: Engineer: Submitted to: Submitted by: Reference: Dimensional Drawing - Indoor Unit apptox.15-3/4 <=1 Piping directioe DiTeexioit for fen open troot easel mates: oulnlde life Lotat ion of unit' 3 Name Plate: Right side surface of casing 2. In case of using wireless remote controller. this position will be a signal receiver.Reter to the drawing of wireless remote contortier in detail, Q L Submittal Data Sheet Approval: Date: 5-12-14 Construction: Unit #: FC-1 Drawing #: r 2 or more ` (Reputed spate) 63-I/8 hole Piping direction 4-1/8 35-1/4 donating letation Hate plate Note)? 41-3/8 Approx. 18-3/4 4-7/8 APProx,11-3/8 (filter part) Ir ltaiale tell part) Approx. 16-3/8 Piping direetiot 7/8 a3-1 8 ho t (Hoist ael xiriat Wake lake 0 i i i 2 or more (8e4ered spate) FAQ18PVJU Daikin AC (Americas), Inc., 1645 Wallace Drive - Suite 110, Carrollton, TX 75006 Page 2 of 4 Daikin AC TRL Generated Submittal Data www.daikinac.com (Dailun's products are subject to canonuous improvements. Daikin reserves the nQrf to modfy product design, specifications and information in thus data shewithout notice and vaginal Marring any obligations) DAIKIN AC® Project Name: absolute comfort Game Fly Tukwila Location: Engineer: Submitted to: Submitted by: Reference: Dimensional Drawing - Condensing Unit 1 1 1 J 1 3-1/2 3/4 Submittal Data Sheet Approval: Date: 5-12-14 Construction: Unit #: HP-1 Drawing #: rt RZR18PVJU Daikin AC (Americas), Inc., 1645 Wallace Drive - Suite 110, Carrollton, TX 75006 Page 3 of 4 Daikin AC TRL Generated Submittal Data www.daikinac.com (Daikin's products are soiled to continuous ingovements. Dalkin reserves the right to madly product deer, epedtications and information in thus data sheet without i notice and without incurring any obligations) DA/KIN 1c absolute comfort Project Name: Location: Game Fly Tukwila Engineer: Submitted to: Submitted by: Reference: FAQ18PVJU Std U.S. Warranty: 7yrs Compressor, 5yrs Parts Approval: Date: Submittal Data Sheet 5-12-14 Construction: Unit #: FC-1/HP-1 Drawing #: RZR18PVJU Std U.S. Warranty: 7yrs Compressor, 5yrs Parts Daikin AC (Americas), Inc., 1645 Wallace Drive - Suite 110, Carrollton, TX 75006 Page 4 of 4 Daikin AC TRL Generated Submittal Data www.daikinac.com (DWdn s products ate subject to continuous improremens. Draken reserves the ngte to modify product casgn. specifications and Information n MI data Neel without notice and %i houl incurring any Widgeons) PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0101 DATE: 05/13/14 PROJECT NAME: GAMEFLY SITE ADDRESS: 12860 INTERURBAN AVE S X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: 1 - AiL c 11 of Building Division Public Works n ISM Cl, Fire Prevention Structural '1 H Planning Division Permit Coordinator III PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 05/15/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06/12/14 Approved Corrections Required n Approved with Conditions n Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 New Equipment Schedule Unit Tag Description MFR CFM Model SEER Sones PH Volts MCA MFA Note FC-1 Indoor Unit DAIKEN 500 FAQ18PVJU 18 43 1 208/230 0.4 15 1,3 HP-1 Outdoor Unit DAIKEN 1835 RZR18PVJU 18 49 1 208/230 16.5 20 2 Notes 1 With Condensate Pump. Run Drain To Roof 2 Mount On Roof Blocks 3 Remote Thermostat WORM. IMON MN RI, BE el..� t .ER,aEBB.L. STRUCTURAL CM. MD LIMOS.. O00111.31011 SMALL OCCUR PON �MO SPECOMTIONS �:� OMR.. MLR. AM MC SYSTEM Melle . TOMIALLATICAL OUR. LAYOUT aOf OS MMB •a•••-^•. powa)r.snywmiwne r.r.RMYES RW MMIEM.E OO REPLMMEM Men MOO. 0.190. OF COM OE Ter. COLOORIATE LOOM. OF KM MOTEL .CCE. O.. rOM esat OM..Me a TO rBBBEBmm I. CEETELEM PROMO. IRO. WOO OR N.O. 1.110 COMECROISwM.O.COLS. TPA. COO. rls Ca POi LLD RMIS 10 MUM DISMSE.MBLY rai DORM FOR OM AS POILE 19044 MAP. FOR 1.41.MEaE. LOwmf MMO OPEN. LRCM. AS D ERRE,R� Ott BB TOWN CROASO B.,�TITECTORBE WK.. 04000.1. S ROMPERS. DUCT 1. 0 USE UCT. PROP. Sa �RnB TOMS TO .0.0.1171.1119 ME ARE ; COMO. MALL MERE TO REGUIRMOOS ETD AS SMALL OE .10E0 MOM .. ALSO CMOVIENTS MU AM P13.11011. AMMO 10 ATLOPFDITS DC OEM. MD CONEMMCD TO RUST T. EFTS. Of BRR LLD ro m , a. or • MME L.TRACTOR IDELERDE .1 MOOR CESOMOOM OKLc -czmw 0.01614 MILO RI DR or ftl1 P11-330 OR 12. OR FOR 301.0 CM SM. • MM. SWUM OF ReSPOMMAY FOR AD1.00 ,B E . ce NCEL Mr Ore. Me M S14J MO. M• nuaESOMr aura' �iD3 iB+ SIOLL Maims a ,ME R mxCWm YOM. BPYME.Y LB<.,.MS. FHamcawrortat 1. MOTORS: ODIAPLT OM MOW OO EMOIEHOES LI000 P COPE E1.0.0 BY ILE 2 MFOR.0 Of AM POMO MO 04. Mr LIMOS WORE N •. 11.110016.3 Me TYPES LOTTO DI MM. RMORWMITS D CCS MOR CMS ,WILMRBE METE 2. pESE/1EMMATATLARt MI PORTS CastaulP TO LCTAMS Pd. COOL MICO.11.> WORD SUPPLY MD REMOaam0 4. RECORD TO TIC BBBE. MUM. Bwnum Einar ,BEUM MI a Pat °R Re 0. POO m BY ,PE aEim w<RomMM. MATT DC D ��) TO OM. uu. OR OM TMELR ORE _ + Mi1MILIMGE w.a PER EMMY C :ol� n �e wwcE EBrE TOCEP1 A. meu E ST.T L�wE°`m rcE�enREr"�"i s.naE&RAM MINCE OMR. MR MERCY C. WORM BY Olt LOOM MU ILE MO MR. 1.111. MPCM 113 ME MAX. A. wIPOE 1Y0,2 Al CYL s — R.LOIRiiWE Qa a ITS.....B.ars4. 55 W.I.Er(PO 110.3EE1101130 M. T003 ACMES PAN. MOM. 111 Tell ROOM COMM etancE OR PARESTEIM ROLE RE,rMroSPEa E,M . OF SWUM D: emu. COAIECIEN PITOUTIMCM. MST. TO OM11OP1iYMMO ON IR 1 W. neA We.. OMER SOOT 01.11.0 KM. ORR. COW MORO. PT Mt LO.L ME OtSaaall TO COMPLY MR Mate CODE WOO. Of LCOL COMM. LS .r am EMSCOMOF SPE.t a ME E Ex ,1.044J CI, ,RR CONTROL EEL. ettleatO TO MUM 071.41.. 1211.0. D ENTS BY ME C.PMCMIA. FOR M.S. CONTROL OTT. COSTRACIERS OR.. v > tun A. MOO OF REPORT. AND T. 0211.0101/ OF MT MORT, nu OOKS) Ill De 01.11.11 MIDERS u SM. s 1. ITE ofDR..00 ETD JAE 11.0 1E DRAM.Mm4s mR6uLPUBMMT M rgayarKalm _ EOEMTOT . , DUCT.. PTb1Sew5 MO 13 DRILL CECPOrMftSUPPORT S. . FOR IMF WA. ON15 M1OMS E.RMO 0.0.L MM. INCLI.E Mu771*,KE wM.)ME SIM Pei T. TOMML 0.TRACTOR • Sky Light a Typical Bathroom Exhaust vent North New HP-1 On Roof Rooftop HVAC Unit SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical Electrical Plumbing Gas Piping ^ity of Tukwila BUILDING DIVISION LZI mE. our a. m ...... masa Ks. as araaa f .4-. 1113- MW,.taa.. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review foes Mechanical & Control Services, Inc. Ductless Split System Rooftop Installation Drawing Piping And Electrical Dog House Roof. In Refer Piping And Electrical outing Support As Needed amm Ca eam wasps.. cour e ®n ece 9 Outdoor Condenser Unit HP-1 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 1 2014 City of +ila BUILDING ISION a si 2004 Celebrating 10 Years! Mechanical & Control Services, Inc. 6426 18th Street East Fife, Washington 98424 (253)926-9777 W W W.Grouamcs.com PRIME COPY Perri* No. AAk`I 01° C Plan review approval is subject to errors and omissions. &pp'ova1 of construction documents does not authorize the vkotation of any adopted code or ordinance. Receipt t approv: Co. (i� t;t.�'lt ns is acknowledged: BY Equipment Roof Supports And Mounting Blocks Roof Roof Penetration Refrigeration Piping Condensate And Electrical Routed From Indoor Unit c-27- 2011% City Of Tukwila BUILDING DIVISION MI±oio a Bpi L LLCD CD E � N � RECEIVED CITY OF TUKWILA MAY 1 3 2014 PERMIT CENTER 1 0f 4 'Roof Plan 12860 Interurban Ave. Tukwila SCOPE WORK ft-FIGNE ONE OFExIST WARMG OFFICE. INSTALL NEW SEERSER ROOM WHIN WAIUNCUSE UTTH GYP BD CELS4 TAX ID. • 211600.0010-09 !BUILDING 4 SITE STATISTICS ETJU.DNG CODE IWC 202 ZONING: 11-I C014STRJCTIOt: TY. E: v-e WRINC.L.BEED OCCUPANCY GROUPS: e 1 S-I>:I ALLOWABLE 8UILDIW AnA- UNLIMITED. PO' YARD ON ALL SIDES. AND FULLY SPRINKLEREO AREA OF EXISTING TENANT SPACE: 10712 SF. AREA OF REMCCEL, APPR?x 300 6;. LEGAL DESCRIPTION LOT 1. GATEWAY CORPORATE CENTER. ACCORDING TO THE PLAT THEREOF. RECORDED IN VOLIME;1 4 OF PLATS. PAGES 23. 24 AND25, IN TONG COUNTY. WASHINGTON: EXCEPT THAT PORTION, IT ANY. DEEDED TO THE CRY OF TUIMR.A FOR SIDEWALK BY DEW RECORDED UNDER NUMBER S393171767- TOGETHER WITH AN'ON{XCLUSNE EASEMENT FOR INGRESS AND EGRESS CREATED BY INSTRUMENT RECORDED UNDER RECORDING NUMBERS 9312222125 AND 13312222126, IN ISHG COUNTY. WASHINGTON. VICINITY MAP N.T.S. REVIEWED FOR CODE COMPLIANCE A MAY 2 2014 City of Tukwila BUILDING DIVISION PLAN NORTH SITE PLAN STALE: l'' 40' NO CHANGES TO SITE OR EXTERIOR OF BUILDING NO CHANGES TO SITE OR EXTERIOR OF BUILDING r i 2004 cp40101 bDZga A 2014 Celebrating 10 Years! Mechanical & Control Services, Inc. 6426 18th Street East Fife, Washington 98424 (253)926-9777 WWW.Groupmcs.com AREA OF WORK RECEIVED CITY OF TUKWILA MAY 1 3 2014 PERMIT CENTER 2 Of 4 IJ EX. RR EX. ADA /L1 EX. OFFICE 1115F01/100=1.1 OCC CO CO EX. WAREI-IOUGE SEMI HEATED MAX S BTUI-I 4;119 SF 1'500 = 9 OCC. SINGLE EXIT, TRAVEL DISTANCE UNDER 100 LF ■ New Ductless Heat Pump. Mounted On Wall. Run All Piping To Roof EX. STORAGE EX. OFFICE 1115Fe1/100=I.1 occ EX. OFFICE 4915F tI/I00.5 OCC • REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 1 2014 City of Tukwila BUILDING DIVISION 2- 4" DIA 1-TOLES TO ABOvE INSULATION AND BELOW CEILING. DEDICATED 30 AT1r STANDARD OUTLET 9 EX. OFFICE 4515Fe1/100:5 OCC 1/ a 2004 Celebrating 10 Years! 2014 Mechanical & Control Services, Inc. 6426 18th Street East Fife, Washington 98424 (253)926-9777 W W W.Groupmcs.com RECEIVED CITY OF TUKWILA MAY 1 3 2014 PERMIT CENTER 3 Of 4 PROVIDE R-I9 IN STUD CAVITY, PROVIDE R-30 OVER FRAMING 1\AA 2X6 CEILING JOISTS g 24" O.G., TOE NAIL TO STUD WALL AND TO BLOCKING WITH 1001 (MIN TWO). STUD WALL TYPE A FULL. THICK INSULATION New Ductless Heat Pump. Install Per MFG Instructions. Run Condensate And Refer Piping To Roof. TYPICAL WALL TO SLAB DETAIL 2/1-2 Remote Thermostat EXISTING STUD WALL VERIFY INSUAATION OR INSTALL FULL THICK INSULATION TO 10'AFF g SECTION AT SERVER SCALE: 3/411 = 1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED MAY 21 2014 City of Tukwila BUILDING DIVISION 0 0dO1SFt, Celebrating 10 Years! Mechanical & Control Services, Inc. 6426 18th Street East Fife, Washington 98424 (253)926-9777 W W W.Groupmcs.com RECEIVED CITY OF TUKWILA MAY 1 3 2014 PERMIT CENTER 4 Of 4