HomeMy WebLinkAboutPermit M14-0101 - GAMEFLY - DUCTLESS SPLIT SYSTEMGAMEFLY
12860 INTERURBAN AVE S
M14-0101
Parcel No:
Address:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
MECHANICAL PERMIT
2716000010
12860 INTERURBAN AVE S BLDG 1
Project Name: GAMEFLY
Permit Number: M14-0101
Issue Date: 5/27/2014
Permit Expires On: 11/23/2014
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
EPROPERTY TAX INC DEPT #207
PO BOX 4900 , SCOTTSDALE, WA,
85261
JOEL SCHUPPERT
6426 18TH ST E , FIFE, WA, 98424
MECHANICAL & CONTROL SRVCS INC
301 PORTER WAY , MILTON, WA,
98354
MECHACS962BT
Phone: (253) 926-9777
Phone: (253) 926-9777
Expiration Date: 2/26/2016
DESCRIPTION OF WORK:
INSTALL 1 NEW 1.5 TON DUCTLESS SPLIT SYSTEM FOR A NEW SERVER ROOM.
Valuation of Work: $3,450.00
Type of Work: NEW
Fuel type: ELECT
Fees Collected: $246.42
Electrical Service Provided by: SEATTLE CITY LIGHT
Water District: TUKWILA
Sewer Distric: TUKWILA SEWER SERVICE
Current Codes adopted by the City of Tukwila:
Internations Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
2012
2012
2012
2012
International Fuel Gas Code:
WA Cities Electrical Code:
WA State Energy Code:
2012
2012
2012
Permit Center Authorized Signature:
(461
Date:
1
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development -rmit and .gee, to the conditions attached to this permit. .
Signatur Date: S_Z 7 - 20 i(1
Print Na 3-66C_ �GH(A.Ped 1
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***MECHANICAL PERMIT CONDITIONS***
2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
3: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
4: Manufacturers installation instructions shall be available on the job site at the time of inspection.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1800 MECHANICAL FINAL
0705 REFRIGERATION EQUIP
0701 ROUGH -IN MECHANICAL
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Mechanical Permit No.
Project No.
1�IL./dl0/
Date Application Accepted:
Date Application Expires:
o s//3//
„/,3/i
(For office use only)
•
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION
Site Address:
King Co Assessor's Tax No.:
12860 Interurban Avenue Tukwila
Tenant Name:
Game Fly
PROPERTY OWNER
Name: EPROPERTY Tax Inc Dept. 207130709
Address: PO Box 4900
City: Scottsdale State: AZ Zip: 85261
CONTACT PERSON — person receiving all project
communication
Name: Joel Schuppert
Address: 6426 18th st east
City: Fife State: Wa Zip: 98424
Phone: (253) 926-9777 Fax: (253) 926-9222
Email: joels@groupmcs.com
2716000010
Suite Number: 12860 Floor: 1
New Tenant: m Yes ❑..No
MECHANICAL CONTRACTOR INFORMATION
Company Name: Mechanical & Control Services, Inc.
Address: 6426 18th street east
City: Fife State: Wa Zip: 98424
Phone: (253) 926-9777 Fax: (253) 926-9222
Contr Reg No.: MECHACS962BT Exp Date: 02/26/2016
Tukwila Business License No.: ql AL).-. 06 tl is
Valuation of project (contractor's bid price): $ 3,450
Describe the scope of work in detail:
Install 1 new 1.5 Ton Ductless Split System For a New Server Room.
Use: Residential: New ❑
Commercial: New
Replacement
Replacement
Fuel Type: Electric Q] Gas ❑
Other:
H:Wpplications\Fonns-Applications On Line\201 I Applications\Mechanical Permit Application Revised 8-9-1 I.docx
Revised: August 2011
bh
Page 1 of 2
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Furnace >100k btu
Floor furnace
Suspended/wall/floor
mounted heater
Appliance vent
Repair or addition to
heat/refrig/cooling
system
Air handling unit
<10,000 cfm
Unit Type
Qty
Air handling unit
>10,000 cfm
Evaporator cooler
Ventilation fan
connected to single duct
Ventilation system
Hood and duct
Incinerator — domestic
Incinerator —
comm/industrial
Unit Type
Qty
Fire damper
Diffuser
Thermostat
Wood/gas stove
Emergency generator
Other mechanical
equipment
Boiler/Compressor
Qty
0-3 hp/100,000 btu
1
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING 'VNER OR AUTHORIZED AGENT:
Signatur
Print Name:
-Joel Schuppert
Mailing Address: 6426 18th street east
H:Wpplications\Fomn-Applications On Line\201 I ApplicationsWechanical Permit Application Revised 8-9-1 I.docx
Revised: August 2011
bh
Day Telephone:
Fife
City
Date: 05/12/2014
(253) 926-9777
WA 98424
State Zip
Page 2 of 2
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188
Permit Inspection Request Line (206) 431-2451
(�1'c7/ 0 it
(206) 431-3670,
Project:_
(___ A,'),\ I J v
Type off Inspection:
,'tA :' (.,/,-,
r
. ,,v /1
\
/
Address: /
12 5 0 0 ..:iA 0,i- J r
a/)
Date Called:
Special Instructions:
fi, \ l
L)C7 !
6D K ' �, .1, ,,
Date Wanted: •
V' ' ' L"
)4
ca.rri'
p.m.
Requester
Phone No:
n
rA
Approved per applicable codes.
t� Corrections required prior to approval.
COMMENTS:
A
/
Inspectors / o - _
�ltrtn.0 j,�
REINSPECTION FEE RE UIRED. Prior to next inspection, fee must/be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
Date: / —t /_ Ld J
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
,/4/i/'0%i
Project:
/r�a€ r�-y
Typ of Inspection: •
/, h - , /%.1
,, 7 / fin (/q�
AdSpecial
Date Called:
Instructions:
Date Wanted:
..—/ , J
`�
1
p.m.
Requester:
Phone No:
'Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
A
l)W6`)<i')- ,,vn - '-1.,u761/tod _
1 _7( ?� n1.SP -r-, t /-( ,a /)
Ins eCtot: ,\
L 3_
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
jaid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Cash Register Receipt
City of Tukwila
DESCRIPTIONS I ACCOUNT I QUANTITY
PermitTRAK
PAID
$246.42
M14-0101 Address: 12860 INTERURBAN AVE S BLDG 1 Apn: 2716000010 $246.42
MECHANICAL $236.94
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$157.05
PLAN CHECK FEE
R000.322.102.00.00
$47.39
TECHNOLOGY FEE $9.48
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R2110
R000.322.900.04.00
$9.48
$246.42
Date Paid: Tuesday, May 13, 2014
Paid By: MECHANICAL & CONTROL SERVICES
Pay Method: CHECK 26714
Printed: Tuesday, May 13, 2014 12:01 PM 1 of 1
CPWSYSTEMS
FILE COIP
VDAIKIN AQ®
Submittal D
absolute comfort
Project Name: Game Fly Tukwila
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Performance
Indoor Unit Model No:
Outdoor Unit Model No:
Rated Cooling Capacity (Btu/hr):
Sensible Capacity (Btu/hr):
Max/Min Cooling Capacity (Btu/hr/kW):
Cooling Input Power (kW):
SEER:
Rated Heating Capacity (Btu/hr):
Max/Min Heating Capacity (Btu/hr/kW):
Heating Input Power (kW):
Heating COP (Btu/hr/Btu/hr):
HSPF:
FAQ18PVJU
RZR18PVJU
18000
13700
Itabook/databook
1.607
18.6
N/A
►tabook/databook
N/A
N/A
N/A
Indoor Unit Details
Power Supply (V/Hz/Ph:)
Power Supply Connections:
Min Circuit Amps MCA (A):
Max OvercurrentAmps MFA (A):
Dimensions (HxWxD):
Panel (HxWxD):
Net Weight (lbs):
Weight with Panel (lbs):
Condensing Unit Details
Power Supply (V/Hz/Ph):
Power Supply Connections:
Min. Circuit Amps MCA (A):
Max. Overcurrent Amps MFA (A):
Max. Starting Current MSC(A):
Rated Load Amps RLA (A):
Dimensions (HxWxD):
Net Weight (lbs):
System Details
Refrigerant Type:
Holding Refrigerant Charge (lbs):
Additional Charge (oz/ft):
Pre -charge Piping (Length ft):
Max. Pipe Length (Total ft):
208-230/60/1 ph
L1, L2, Ground
0.4
15
11-3/8x41-3/8x9
N/A
31
208-230/60/1 ph
L1, L2, Ground
16.5
20
7.1
30-5/16x35-7/16x12-5/8
150
R-410A
5.1
0.036Ibs/ft
164 ft
Approval:
Date: 5-12-14
Construction:
Unit #: FC-1/HP-1
Drawing #:
Indoor Unit Type:
Condensing Unit Type:
Rated Cooling
Conditions
eF
VIEWEDOR
CODE COMPLIANCE
APPROVED
MAY 21 2014
of Tukwila
BUILDING DIVISION
Wall Mounted
SkyAir Cool Only
Indoor: 80°F DB/67°F WB
Outdoor: 95°F DB/75°F WB
Rated Heating
Conditions
Indoor: N/A
Outdoor: N/A
Rated Piping Length(ft)
Rated Height Separation(ft)
25
0
Airflow Rate (CFM wet coil)
Moisture Removal (pt/h):
Gas Pipe Connection (inch):
Liquid Pipe Connection (inch):
Condensate Connection (inch):
Sound Pressure Level (dBA):
Sound Power Level (dBA):
Static Pressure Rated/Max (inWg)
Compressor Type:
Capacity Control Range (%):
Airflow Rate (CFM):
Gas Pipe Connection (inch):
Liquid Pipe Connection (inch):
Sound Pressure Level (dBA):
Sound Power Level (dBA):
Max. Pipe Length (Vertical ft):
Cooling Operation Range (F):
Cooling Range w/Baffle (F):
Heating Operation Range (F):
Heating Range w/Baffle (`F):
VI I 0 ( 0 I
500//400
5/8
3/8
1
43
0/0/0
Inverter
35 - 100
1835
5/8
3/8
49
98 ft
23 - 115
RiIVED
CITY OfurUKWILA
MAY 1 3 2014
PERMIT CENTER
Daikin AC (Americas), Inc., 1645 Wallace Drive - Suite 110, Carrollton, TX 75006 Page 1 of 4
Daikin AC TRL Generated Submittal Data www.daikinac.com
)Daikin's products are subject to continuous improvements. Dalin reserves the right to modify product design, spsalicalions and information in this data sheet without notice and without incurring any obligations)
VDAIKIN AC°
absolute comfort
Project Name: Game Fly Tukwila
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Dimensional Drawing - Indoor Unit
apptox.15-3/4
<=1
Piping directioe
DiTeexioit for
fen open troot easel
mates: oulnlde life
Lotat ion of unit' 3 Name Plate:
Right side surface of casing
2. In case of using wireless remote
controller. this position will be
a signal receiver.Reter to the
drawing of wireless remote contortier
in detail,
Q
L
Submittal Data Sheet
Approval:
Date: 5-12-14
Construction:
Unit #: FC-1
Drawing #:
r
2 or more `
(Reputed spate)
63-I/8 hole
Piping direction
4-1/8 35-1/4
donating letation
Hate plate Note)?
41-3/8
Approx. 18-3/4
4-7/8 APProx,11-3/8
(filter part) Ir ltaiale tell part)
Approx. 16-3/8
Piping direetiot
7/8
a3-1 8 ho t
(Hoist ael
xiriat Wake
lake
0
i
i
i
2 or more
(8e4ered spate)
FAQ18PVJU
Daikin AC (Americas), Inc., 1645 Wallace Drive - Suite 110, Carrollton, TX 75006 Page 2 of 4
Daikin AC TRL Generated Submittal Data www.daikinac.com
(Dailun's products are subject to canonuous improvements. Daikin reserves the nQrf to modfy product design, specifications and information in thus data shewithout notice and vaginal Marring any obligations)
DAIKIN AC®
Project Name:
absolute comfort
Game Fly Tukwila
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Dimensional Drawing - Condensing Unit
1
1
1 J
1
3-1/2 3/4
Submittal Data Sheet
Approval:
Date: 5-12-14
Construction:
Unit #: HP-1
Drawing #:
rt
RZR18PVJU
Daikin AC (Americas), Inc., 1645 Wallace Drive - Suite 110, Carrollton, TX 75006 Page 3 of 4
Daikin AC TRL Generated Submittal Data www.daikinac.com
(Daikin's products are soiled to continuous ingovements. Dalkin reserves the right to madly product deer, epedtications and information in thus data sheet without i notice and without incurring any obligations)
DA/KIN 1c
absolute comfort
Project Name:
Location:
Game Fly Tukwila
Engineer:
Submitted to:
Submitted by:
Reference:
FAQ18PVJU
Std U.S. Warranty: 7yrs Compressor, 5yrs Parts
Approval:
Date:
Submittal Data Sheet
5-12-14
Construction:
Unit #: FC-1/HP-1
Drawing #:
RZR18PVJU
Std U.S. Warranty: 7yrs Compressor, 5yrs Parts
Daikin AC (Americas), Inc., 1645 Wallace Drive - Suite 110, Carrollton, TX 75006 Page 4 of 4
Daikin AC TRL Generated Submittal Data www.daikinac.com
(DWdn s products ate subject to continuous improremens. Draken reserves the ngte to modify product casgn. specifications and Information n MI data Neel without notice and %i houl incurring any Widgeons)
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M14-0101 DATE: 05/13/14
PROJECT NAME: GAMEFLY
SITE ADDRESS: 12860 INTERURBAN AVE S
X Original Plan Submittal Revision # before Permit Issued
Response to Correction Letter # Revision # after Permit Issued
DEPARTMENTS:
1 - AiL c 11 of
Building Division
Public Works
n
ISM Cl,
Fire Prevention
Structural
'1 H
Planning Division
Permit Coordinator III
PRELIMINARY REVIEW:
Not Applicable
(no approval/review required)
DATE: 05/15/14
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 06/12/14
Approved
Corrections Required
n
Approved with Conditions n
Denied
(corrections entered in Reviews) (ie: Zoning Issues)
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
New Equipment Schedule
Unit Tag
Description
MFR
CFM
Model
SEER
Sones
PH
Volts
MCA
MFA
Note
FC-1
Indoor Unit
DAIKEN
500
FAQ18PVJU
18
43
1
208/230
0.4
15
1,3
HP-1
Outdoor Unit
DAIKEN
1835
RZR18PVJU
18
49
1
208/230
16.5
20
2
Notes
1 With Condensate Pump. Run Drain To Roof
2 Mount On Roof Blocks
3 Remote Thermostat
WORM. IMON MN RI, BE
el..� t .ER,aEBB.L.
STRUCTURAL CM. MD LIMOS..
O00111.31011 SMALL OCCUR PON �MO SPECOMTIONS
�:�
OMR.. MLR. AM MC SYSTEM Melle
. TOMIALLATICAL OUR. LAYOUT
aOf OS MMB
•a•••-^•. powa)r.snywmiwne
r.r.RMYES RW MMIEM.E OO
REPLMMEM Men MOO. 0.190. OF
COM OE Ter. COLOORIATE LOOM. OF
KM MOTEL .CCE. O.. rOM esat OM..Me
a TO
rBBBEBmm
I. CEETELEM PROMO. IRO. WOO OR
N.O. 1.110 COMECROISwM.O.COLS. TPA. COO. rls
Ca POi LLD RMIS 10 MUM DISMSE.MBLY rai
DORM FOR OM AS POILE
19044 MAP. FOR 1.41.MEaE. LOwmf
MMO
OPEN. LRCM. AS D ERRE,R�
Ott BB
TOWN CROASO
B.,�TITECTORBE WK.. 04000.1. S ROMPERS.
DUCT
1.
0 USE
UCT. PROP.
Sa
�RnB TOMS TO
.0.0.1171.1119
ME ARE
;
COMO. MALL MERE TO REGUIRMOOS ETD
AS SMALL OE .10E0 MOM .. ALSO
CMOVIENTS MU AM P13.11011. AMMO 10
ATLOPFDITS DC OEM. MD
CONEMMCD TO RUST T. EFTS. Of
BRR LLD ro m , a. or • MME L.TRACTOR IDELERDE .1 MOOR CESOMOOM OKLc -czmw
0.01614 MILO RI DR
or ftl1 P11-330 OR
12. OR FOR 301.0 CM SM. • MM. SWUM OF ReSPOMMAY
FOR AD1.00
,B E . ce NCEL Mr Ore. Me M S14J
MO. M• nuaESOMr aura' �iD3 iB+ SIOLL Maims a
,ME R mxCWm YOM. BPYME.Y LB<.,.MS.
FHamcawrortat
1. MOTORS: ODIAPLT OM MOW OO
EMOIEHOES LI000 P COPE E1.0.0 BY
ILE
2 MFOR.0 Of AM POMO MO 04.
Mr LIMOS WORE N •. 11.110016.3 Me TYPES LOTTO DI MM. RMORWMITS D CCS
MOR
CMS ,WILMRBE METE
2. pESE/1EMMATATLARt MI PORTS CastaulP TO
LCTAMS Pd. COOL
MICO.11.> WORD
SUPPLY MD REMOaam0
4. RECORD TO TIC BBBE.
MUM. Bwnum Einar ,BEUM MI a Pat °R Re 0. POO m BY ,PE
aEim w<RomMM. MATT DC D ��) TO
OM. uu.
OR OM TMELR ORE _ + Mi1MILIMGE w.a PER EMMY C :ol� n
�e wwcE EBrE
TOCEP1 A. meu E ST.T L�wE°`m rcE�enREr"�"i s.naE&RAM MINCE OMR. MR
MERCY C. WORM BY Olt LOOM MU ILE
MO MR. 1.111. MPCM 113 ME MAX.
A. wIPOE 1Y0,2 Al CYL s — R.LOIRiiWE Qa a ITS.....B.ars4. 55 W.I.Er(PO
110.3EE1101130
M. T003 ACMES PAN. MOM. 111 Tell ROOM
COMM
etancE OR
PARESTEIM ROLE RE,rMroSPEa E,M
. OF SWUM
D: emu.
COAIECIEN PITOUTIMCM. MST. TO
OM11OP1iYMMO ON IR 1 W.
neA We..
OMER SOOT 01.11.0 KM.
ORR. COW MORO. PT Mt LO.L ME
OtSaaall TO COMPLY MR Mate CODE
WOO. Of LCOL COMM. LS
.r am EMSCOMOF SPE.t a ME
E Ex ,1.044J CI, ,RR CONTROL EEL.
ettleatO TO MUM 071.41.. 1211.0. D ENTS BY ME
C.PMCMIA. FOR M.S. CONTROL OTT.
COSTRACIERS OR.. v > tun
A. MOO OF REPORT. AND T.
0211.0101/ OF MT MORT,
nu OOKS) Ill De 01.11.11
MIDERS u SM. s 1. ITE ofDR..00 ETD
JAE
11.0 1E DRAM.Mm4s mR6uLPUBMMT
M
rgayarKalm _ EOEMTOT . , DUCT.. PTb1Sew5
MO 13 DRILL CECPOrMftSUPPORT S.
. FOR
IMF WA. ON15 M1OMS E.RMO 0.0.L MM.
INCLI.E Mu771*,KE wM.)ME SIM
Pei T. TOMML 0.TRACTOR
•
Sky Light a
Typical
Bathroom
Exhaust
vent
North
New HP-1
On Roof
Rooftop
HVAC
Unit
SEPARATE PERMIT
REQUIRED FOR:
❑ Mechanical
Electrical
Plumbing
Gas Piping
^ity of Tukwila
BUILDING DIVISION
LZI
mE.
our a. m ......
masa Ks. as
araaa
f .4-.
1113- MW,.taa..
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review foes
Mechanical & Control Services, Inc.
Ductless Split System Rooftop
Installation Drawing
Piping And
Electrical
Dog House
Roof. In
Refer Piping
And Electrical
outing
Support
As Needed
amm
Ca eam
wasps.. cour
e ®n
ece
9
Outdoor Condenser
Unit HP-1
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 2 1 2014
City of +ila
BUILDING ISION
a
si 2004
Celebrating 10 Years!
Mechanical & Control Services, Inc.
6426 18th Street East
Fife, Washington 98424
(253)926-9777
W W W.Grouamcs.com
PRIME COPY
Perri* No. AAk`I 01° C
Plan review approval is subject to errors and omissions.
&pp'ova1 of construction documents does not authorize
the vkotation of any adopted code or ordinance. Receipt
t approv: Co. (i� t;t.�'lt ns is acknowledged:
BY
Equipment Roof Supports
And Mounting Blocks
Roof
Roof Penetration
Refrigeration Piping
Condensate And
Electrical Routed
From Indoor Unit
c-27- 2011%
City Of Tukwila
BUILDING DIVISION
MI±oio
a
Bpi
L
LLCD CD
E
� N �
RECEIVED
CITY OF TUKWILA
MAY 1 3 2014
PERMIT CENTER
1 0f 4
'Roof Plan 12860 Interurban Ave. Tukwila
SCOPE
WORK
ft-FIGNE ONE OFExIST WARMG OFFICE. INSTALL NEW SEERSER ROOM WHIN
WAIUNCUSE UTTH GYP BD CELS4
TAX ID. •
211600.0010-09
!BUILDING 4 SITE STATISTICS
ETJU.DNG CODE IWC 202
ZONING: 11-I
C014STRJCTIOt: TY. E: v-e WRINC.L.BEED
OCCUPANCY GROUPS: e 1 S-I>:I
ALLOWABLE 8UILDIW AnA- UNLIMITED. PO' YARD ON ALL SIDES.
AND FULLY SPRINKLEREO
AREA OF EXISTING TENANT SPACE: 10712 SF.
AREA OF REMCCEL, APPR?x 300 6;.
LEGAL DESCRIPTION
LOT 1. GATEWAY CORPORATE CENTER. ACCORDING TO THE PLAT THEREOF. RECORDED IN VOLIME;1 4 OF PLATS. PAGES 23.
24 AND25, IN TONG COUNTY. WASHINGTON: EXCEPT THAT PORTION, IT ANY. DEEDED TO THE CRY OF TUIMR.A FOR
SIDEWALK BY DEW RECORDED UNDER NUMBER S393171767-
TOGETHER WITH AN'ON{XCLUSNE EASEMENT FOR INGRESS AND EGRESS CREATED BY INSTRUMENT RECORDED UNDER
RECORDING NUMBERS 9312222125 AND 13312222126, IN ISHG COUNTY. WASHINGTON.
VICINITY MAP
N.T.S.
REVIEWED FOR
CODE COMPLIANCE
A
MAY 2 2014
City of Tukwila
BUILDING DIVISION
PLAN NORTH SITE PLAN
STALE: l'' 40'
NO CHANGES TO SITE OR
EXTERIOR OF BUILDING
NO CHANGES TO SITE OR
EXTERIOR OF BUILDING
r
i
2004
cp40101 bDZga
A
2014
Celebrating 10 Years!
Mechanical & Control Services, Inc.
6426 18th Street East
Fife, Washington 98424
(253)926-9777
WWW.Groupmcs.com
AREA OF WORK
RECEIVED
CITY OF TUKWILA
MAY 1 3 2014
PERMIT CENTER
2 Of 4
IJ
EX. RR
EX. ADA
/L1
EX. OFFICE
1115F01/100=1.1
OCC
CO CO
EX. WAREI-IOUGE
SEMI HEATED MAX S BTUI-I
4;119 SF 1'500 = 9 OCC.
SINGLE EXIT, TRAVEL DISTANCE UNDER 100 LF
■
New Ductless
Heat Pump. Mounted
On Wall. Run All
Piping To Roof
EX. STORAGE
EX. OFFICE
1115Fe1/100=I.1
occ
EX. OFFICE
4915F tI/I00.5
OCC
•
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 2 1 2014
City of Tukwila
BUILDING DIVISION
2- 4" DIA 1-TOLES TO
ABOvE INSULATION AND
BELOW CEILING.
DEDICATED 30 AT1r
STANDARD OUTLET
9
EX. OFFICE
4515Fe1/100:5
OCC
1/
a
2004
Celebrating 10 Years!
2014
Mechanical & Control Services, Inc.
6426 18th Street East
Fife, Washington 98424
(253)926-9777
W W W.Groupmcs.com
RECEIVED
CITY OF TUKWILA
MAY 1 3 2014
PERMIT CENTER
3 Of 4
PROVIDE R-I9 IN STUD CAVITY,
PROVIDE R-30 OVER FRAMING
1\AA
2X6 CEILING JOISTS g 24" O.G.,
TOE NAIL TO STUD WALL AND TO BLOCKING WITH
1001 (MIN TWO).
STUD WALL TYPE A
FULL. THICK INSULATION
New Ductless
Heat Pump. Install
Per MFG Instructions.
Run Condensate And
Refer Piping To Roof.
TYPICAL WALL TO SLAB
DETAIL 2/1-2
Remote
Thermostat
EXISTING STUD WALL VERIFY INSUAATION OR
INSTALL FULL THICK
INSULATION TO 10'AFF
g SECTION AT SERVER
SCALE: 3/411 = 1'-0"
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 21 2014
City of Tukwila
BUILDING DIVISION
0 0dO1SFt,
Celebrating 10 Years!
Mechanical & Control Services, Inc.
6426 18th Street East
Fife, Washington 98424
(253)926-9777
W W W.Groupmcs.com
RECEIVED
CITY OF TUKWILA
MAY 1 3 2014
PERMIT CENTER
4 Of 4