Loading...
HomeMy WebLinkAboutPermit M14-0103 - LULULEMON - SPLIT HVAC SYSTEMLULULEMON 21 S OUTHCENTER MALL M14-0103 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No: 9202470130 Permit Number: M14-0103 Address: 21 SOUTHCENTER MALL Issue Date: 8/13/2014 Permit Expires On: 2/9/2015 Project Name: LULULEMON Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD, CA, 92013 Contact Person: Name: MELANI DANNENBERG Address: 20521 EARL STREET, TORRANCE, CA, 90503 Phone: (310) 263-3587 Contractor: Name: EVERGREEN REFRIGERATION LLC Phone: (206) 763-1744 Address: 727 S KENYON ST, SEATTLE, WA, 98108 License No: EVERGRL954R2 Expiration Date: 1/6/2016 Lender: Name: Address: , DESCRIPTION OF WORK: INSTALL DUCT, DUCT SUPPORTS, AND DIFFUSERS FOR EXISTING SPLIT HVAC SYSTEM. Valuation of Work: $35,000.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $650.92 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: Permit Center Authorized Signature: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 AstkcA 2012 2012 2012 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature:U" Date: a / (3 /U ,(�f Print Name: r - This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***MECHANICAL PERMIT CONDITIONS*** 2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. m Project No. Date Application Accepted: 114 Date Application Expires: ' I Ilt4\ 11 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 21 SOUTHCENTER King Co Assessor's Tax No.: 2 ` 2 1 Suite Number: 748 Floor: 1ST Tenant Name: LULULEMON PROPERTY OWNER Name: WESTFIELD, LLC Address: 2800 SOUTHCENTER City: SEATTLE State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: MELANI DANNENBERG Address: 20521 EARL ST City: TORRANCE State: CA Zip: 90503 Phone: (310) 263-3587 Fax: (775) 766-9742 Email: MDANNENBERG@MENEMSHASOLUTIC New Tenant: ❑ Yes MECHANICAL CONTRACTOR INFORMATION Company Name: T.B.D. Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ 35,000 Describe the scope of work in detail: Install duct, duct supports, and diffusers for existing split HVAC system. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement ❑ Fuel Type: Electric ❑ Gas ❑ Other: H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu 0 Furnace >100k btu 0 Floor furnace 0 Suspended/wall/floor mounted heater 0 Appliance vent 0 Repair or addition to heat/refrig/cooling system 0 Air handling unit <10,000 cfm 0 Unit Type Qty Air handling unit >10,000 cfm 0 Evaporator cooler 0 Ventilation fan connected to single duct 0 Ventilation system 0 Hood and duct 0 Incinerator —domestic 0 Incinerator — comm/industrial 0 Unit Type Qty Fire damper 0 Diffuser 17 Thermostat 0 Wood/gas stove 0 Emergency generator 0 Other mechanical equipment 2 Boiler/Compressor Qty 0-3 hp/100,000 btu 0 3-15 hp/500,000 btu 0 15-30 hp/1,000,000 btu 0 30-50 hp/1,750,000 btu 0 50+ hp/1,750,000 btu 0 PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING / N�ER OR TIIORIZED AGENT: Signature: ,/Ar k, Date: 5/13/N Print Name: MELANI DANNENBERG Day Telephone: (310) 263-3587 Mailing Address: 20521 EARL ST TORRANCE CA 90503 City State Zip H:Wpplications\Forrns-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT PermitTRAK QUANTITY PAID $1,791.53 EL14-0786 Address: 21 SOUTHCENTER MALL Apn: 9202470130 $81.80 ELECTRICAL $77.90 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 I 0.00 $77.90 TECHNOLOGY FEE $3.90 TECHNOLOGY FEE R000.322.900.04.00 I 0.00 $3.90 EL14-0787 Address: 230 SOUTHCENTER MALL Apn: 9202470130 $81.80 ELECTRICAL $77.90 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $77.90 TECHNOLOGY FEE $3.90 TECHNOLOGY FEE R000.322.900.04.00 0.00 $3.90 M14-0103 Address: 21 SOUTHCENTER MALL Apn: 9202470130 $525.74 MECHANICAL $500.70 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $468.20 TECHNOLOGY FEE $25.04 TECHNOLOGY FEE R000.322.900.04.00 0.00 $25.04 M14-0118 Address: 230 SOUTHCENTER MALL Apn: 9202470130 $1,102.19 MECHANICAL $1,049.70 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $1,017.20 TECHNOLOGY FEE $52.49 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2852 R000.322.900.04.00 0.00 $52.49 $1,791.53 Date Paid: Wednesday, August 13, 2014 Paid By: EVERGREEN REFRIGERATION LLC Pay Method: CHECK 006622 Printed: Wednesday, August 13, 2014 9:13 AM 1 of 1 CPWSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT I QUANTITY I PAID $3,237.04 D14-0150 Address: 21 SOUTHCENTER MALL Apn: 9202470130 $2,092.04 DEVELOPMENT $2,092.04 PLAN CHECK FEE R000.345.830.00.00 $2,087.54 WASHINGTON STATE SURCHARGE 8640.237.114 $4.50 EL14-0465 Address: 21 SOUTHCENTER MALL Apn: 9202470130 $842.94 ELECTRICAL $802.80 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 $802.80 TECHNOLOGY FEE $40.14 TECHNOLOGY FEE R000.322.900.04.00 $40.14 M14-0103 Address: 21 SOUTHCENTER MALL Apn: 9202470130 $125.18 MECHANICAL $125.18 PLAN CHECK FEE R000.322.102.00.00 $125.18 PG14-0080 Address: 21 SOUTHCENTER MALL Apn: 9202470130 $176.88 PLUMBING $176.88 PLAN CHECK FEE R000.322.103.00.00 $41.88 PERMIT FEE TOTAL FEES PAID BY RECEIPT: R2124 R000.322.100.00.00 $135.00 $3,237.04 Date Paid: Wednesday, May 14, 2014 Paid By: MENEMSHA DEVELOPMENT GROUP Pay Method: CHECK 013245 Printed: Wednesday, May 14, 2014 2:16 PM 1 of 1 C! SYSTEMS 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Type off lnspectiofl: Addres: S 0 �i A L. Date Called: Special Instructions: Date Wanted: j O —Z Z— t `( (a.r—fq p.m. 1 equester: Phone No: �JApproved per applicable codes. DCorrections required prior to approval. COMMENTS: i) a KN S htc( c..k.,04.) -- APP./ea-4 2..) -- r tv\ t 05-0,4 1 s dc? % I-' N A 1 Ins ector: j\iNSPECTION PEE REQ IRED. Prior to next inspection, fee must be paid at 6300 Southcenter lvd.. Suite 100. Call to schedule reinspection. Date: ,22-- ?Li INSPECTION RECORD Retain a copy with permit INSPECTION NO, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 MILi-0lc� Project: f L-Z t LZ t L f wL cs�J Type f Inspection: . �Z AVA 1.1 - i N1 Address: 2 -- ` ``.di(` ;IA t t Date Called: Special Instructions: Date lWaante� l f J p.m. Requester: Phone No: Approved per applicable codes. IJ Corrections required prior to approval. COMMENTS: In°s Date: /REINSPECTION FEE WEQUIRED. Prior to next inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. j INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 W1 I J-a«3 Project: TYPe\f 9Inspection: I Address: ad C 11 I 1 Date Called: Special Instructions: Date Wanted: Z ( (44 a m`. p.m. Requeste(-1 0 S `_ Phone No:. Approved per applicable codes. El Corrections required prior to approval. COMMENTS: p, (:,_ (I . C' !I- ; (-) ��&_1 sz(L-,41-vc i>11 - N 1.4 ;-:, ,.., • Inspector: id►^14 ri tftEINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Dat 2_ 1--1 EVERGREEN REFRIGERATION, LLC 727SKENYONST. SEATTLE, WA. 98108 206-763-1744 CONTR. # EVERGI201 D7 TEST AND BALANCE REPORT Project: L-ULj L$M411/4.1 Evergreen Job #: Date: /d,/aWiq Location: g SoCExmAz- r"4'V Engineer: EVERGREEN REFRIGERATION LLC Evergreen Refrigeration LLC, has balanced the system described in accordance with the plans, specifications, and within the limitations of the equipment. The testing, balancing, and adjusting has been performed in accordance with industry standards. The results of these tests are herein recorded. Commissioning Technician: IAJ w.k.) Date completed: / o/z /iq EVERGREEN REFRIGERATION, LLC AIR OUTLET TEST REPORT - SUPPLY Page 1 Project: t-t)Li,, Job #: Date: 14: /vto tj Unit # Area Served Outlet Design Target Preliminary Final No Type Size C.F.M. C.F.M. C.F.M. C.F.M. C.F.M. 14 i i 1, 1 •L 'fr." 2'-' 1/212 /4 50 L130 1 , -_Af, 0 el ' •:) 1 i--1 , f- c 41`70 41q0 Lfl ''1(ci6, )1.10 2'OO e7(1:)-.6 - I 1 e `,, r ---7 1 : ,7"-- 1 -1 (:,,' ) ; : ./ ) el 'ft- 3 ex,e, 264.5D t25y4 ig)o' 5-.',o 73 320 3\0 A i "‹.x. 9 __..) 2 -, 36 0 3,0 , - •-", ".:7 -2, "7 t . -,-;').-7 ...7;,e X) 3 I in ; 70 . '. 0 ": 47.7 „... ....) ....- 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Summary 2012 Washin ]„S.ta pli nce Forms for Commercial, Group R1, and > 3 story R2 and R3 Project InRiVLtEc CODE COMlANCt eject Address APPROVED MAY21 2014 Ap icant Name: RANDALL NELSON Project Briefly descri system type and features. esc 21 SOUTHCENTER, SUITE 748 MECH-SUM Date Revised June 2013 5/9/2014 TUXWILA, WA 98188 For Building Dept. Use ❑ Includes Plans Ap icant Address: 14817 W 957TH ST, LENEXA, KS 66214 App`cant Phone: 913-322-5150 oPvieiktila 111 DIVISION P Include documentation requiring compliance with commissioning provisions per Section C408. Compliance Option 0 Simple System ® Complex System 0 Systems Analysis The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equipment Schedules Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu/h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exceptions Heat Recovery Y/N Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu/h OSA cfm or Econo? Input Btuh Output Btuh Heat Recovery E b�N LA Fan Equipment Schedu Equip. ID Equip Type Brand Name' Model No.1 CFM SP' HP/BHP Flow Controls C............ VAT_t___ TT _ _ . _ _. Equip. ID Equip Type quipment Schedule Location of Service Brand Name' Model No.1 Input Capacity Sub - Category EFT Location of Service EWH-1 WATER HEATER AO SMITH DEL-6 2.5 KW 0.99 MOP CLOSET 1 If available. 2 As tested according to Table C403.2.3(1)A thru C403.2.3(8). 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume (VAV), constant volume (CV), or variable speed (VS). 6 Ecoizer exception number per AAIL4-OIQ Mechanical Permit Plans Checklist Page 1 of 3 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Project Address 21 SOUTHCENTER, SUITE 748 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. I I Applicability (yes,no,na) Code Section Code Provision Equipment Sizing & Performance NA NA NA NA NA NA NA NA NA NA NA NA NA C403.2.1 C403.2.2 C403.2.5 C403.2.3 & C403.2.3.2 & C403.2.12.1 C403.2.13 C403.2.10 C403.2.10.3 & C403.2.13 C403.2.3 C403.2.1 C403.2.12.1.2 C403.2.3 C403.2.3.3 C403.2.3.4 Information Required GENERAL PROVISIONS 'Date Revised June 2013 5/9/2014 Location on Building Department Plans I Notes Load calculations Equipment and system sizing Minimum ventilation Equipment minimum efficiency Electric motor efficiency Fan power limitation Fractional hp fan motors Maximum air cooled chiller capacity Non-standard water-cooled chillers Centrifugal fan cooling towers Forced air fumace and unit heaters Packaged electric heating/cooling equipment Humidification HVAC System Controls & Criteria NA NA NA YES NA NA NA NA NA NA NA NA NA NA NA NA NA NA C403.2.4.1 C403.2.4.1.1 C403.2.4.2 C403.2.4.3 C403.2.4.3.3 C402.4.5.2 & C403.2.4.4 C403.2.11 C403.2.4.5 C403.2.4.6 C403.2.4.7 C403.2.4.8 / 9 C403.2.5.1 C403.2.5.2 C403.2.5.3 C403.2.5.4.1 C403.2.5.4.2 C403.2.6.1 C403.2.6.2 Thermostatic controls Heat pump supplementary heat Setpoint overlap (deadband) Automatic setback and shutdown Automatic (optimum) start Dampers Heating outside a building Snow melt systems Combustion heating equipment Group R1 hotel/motel systems Group R2/R3 dwelling unit systems Demand controlled ventilation Occupancy sensors Enclosed loading dock/parking garage ventilation Kitchen exhaust hoods Laboratory exhaust systems Energy recovery - ventilation systems Energy recovery - condensate systems Energy recovery - condenser systems Load calculations performed per ASHRAE Std 183 or equivalent per Chapter 3 Output capacity of heating and cooling equipment and systems do not exceed calculated loads, note exceptions taken Ventilation (natural or mechanical) provided per IMC; indicate mechanical ventilation is capable of being reduced to minimum requirement per IMC Provide equipment schedules or complete MECH-SUM tables with type, capacity, efficiency, test standard (or other efficiency source) for all mechanical equipment Provide equipment schedule except. Fan system motor hp or bhp C403.2.10.1(1) Indicate fan motors 1/12 to 1 req. with hp, rpm, efficiency for all motors; note does not exceed limits per Table hp are ECM type or meet minimum efficiency Indicate air-cooled chiller capacity does not exceed air-cooled chiller limit Full -load and NPLV values for water-cooled centrifugal chiller adjusted for non-standard operational conditions Large capacity cooling towers with centrifugal fan(s) meet efficiency requirements for axial fan open circuit cooling towers Indicate intermittent ignition or IID, flue/draft damper & jacket loss List equipment required to be heat pumps on schedule Indicate method of humidification (note requirements for systems with economizer) Indicate locations of thermostatic control zones on plans, including perimeter systems Indicate staged heating (compression/supplemental) & outdoor lock -out temp Indicate 5°F deadband minimum for systems controlling both heating & cooling Indicate zone t-stat controls with required automatic setback & manual override Indicate system controls that adjust equip start time to match Toad conditions Indicate location of OSA, exhaust, relief and retum air dampers; include AMCA rated leakage and control type (motorized or gravity; note exceptions Indicate radiant heat system and occupancy controls Indicate shut-off controls based on outdoor conditions Indicate modulating or staged control Indicate method for guest room automatic setback & set-up of 5°F minimum Indicate 5-2 programmable thermostats in primary spaces with minimum of two setback periods; note exceptions taken Indicate high -occupancy spaces and systems requiring DCV Indicate spaces requiring occupancy -based system control and method; or altemate means provided to automatically reduce OSA when partially Indicate enclosed loading dock and enclosed parking garage ventilation system activation and control method Indicate kitchen hoods requiring make-up air; indicate make-up air source and conditioning method Indicate lab exhaust systems requiring heat recovery, method & efficiency; or alternative method taken (VAV, semi -conditioned makeup, or CERM calculation) Indicate ventilation systems requiring ER, method & efficiency; note exceptions Indicate on -site steam heating systems requiring energy recovery M110 NA C403.2.6.3 Indicate remote refrig. condensers requiring ER and use of captured energy Mechanical Permit Plans Checklist - Page 2 of 3 MECH-CHK 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Project Address 21 SOUTHCENTER, SUITE 748 Revised June 2013 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. ApplicabilitylCode Section I (yes,no,na) Code Provision HVAC System Controls & Criteria, Continued NA NA NA NA C403.2.12 C403.2.12.1 C403.2.12.2 C403.2.12.2 Variable flow control - fans/pumps Variable flow control - coolinq towers Large volume fan systems Single zone AC systems Information Required GENERAL PROVISIONS, CONTINUED 'Date 5/9/2014 ILocation Building Department on Plans I Notes Indicate fan & pump motors requiring VF control & method (VSD or equiv controls) Indicate cooling tower fans requiring variable flow control and method Indicate fan systems requiring airflow reduction based on heating and cooling demand; or exception taken Indicate method of cooling demand -based fan control for sys. > 110,000 btuh NA C403.2.4.10 Ducting Systems YES NA NA YES C403.2.7.1 & C403.2.7.3 C403.2.7.3.3 C403.2.7.1 / 2 DDC system capabilities Identify all DDC system input/output control points and indicate capability for trending and demand response setooint adiustment Duct construction Duct pressure classifications High pressure duct leakage test Duct insulation Indicate all ductwork constructed and sealed per IMC, C402 leakage requirements and IBC vapor retarder requirements Identify location of low, medium and high pressure ductwork on plans Indicate high pressure duct leakage testing requirements on plans; provide test results to jurisdiction when completed Indicate R-value of insulation on ductwork M611 M611 Piping Systems YES C403.2.8 Piping insulation Indicate R-value of insulation on piping C403.2.8.1 Piping insulation exposed to Indicate method of rote NA weather protection from damage/degredation Qualifying Systems NA NA C403.3 C403.3 Qualifying single zone systems SIMPLE SYSTEMS P520 Qualifying 2-pipe heating systems Verify unitary or packaged equipment does not exceed capacity limits, does not have active humidifcation or simultaneous heating/cooling Verify 2-pipe heating -only system does not exceed capacity limits NA C403.3.2 Hydronic system controls Refer to Complex Systems Section C403.4.3 Simple System Economizers NA C403.3.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip sched. NA NA C403.3.1.1.1 C403.3.1.1.3 NA NA C403.1.1.2 C403.3.1 Air economizer capacity Air economizer high limit controls Integrated air economizer operation Air economizer exceptions Indicate modulating OSA control capability up to 100% OSA, or exception Indicate high limit shut-off control method per Table C403.3.1.1.3(2) Indicate capability for partial air economizer operation for systems with capacity > 65,000 btuh Indicate eligible exception(s) taken and provisions to comply with exception(s) COMPLEX SYSTEMS Complex System Economizers NA C403.4.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip sched. NA C403.4.1.4 NA C403.4.1.3 Economizer heating system impact Integrated economizer operation Verify control method of HVAC systems with economizers does not increase building heating energy usage during normal operation Indicate capability for partial economizer operation for air or water econo systems NA Moved Water economizer capacity Indicate water econo capable of 100% cooling capacity at 50°F db/45°F wb OSA NA C403.4.1.2 Water economizer maximum pressure drop Indicate precooling coils and heat exchangers do not exceed pressure drop limit NA C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exceo1ion(s) Mechanical Permit Plans Checklist - Page 3-of 3' MECH-CHK 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Project Address 21 SOUTHCENTER, SUITE 748 Revised June 2013 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Code Provision I Information Required Applicability (yes,no,na) Code Section) Date COMPLEX SYSTEMS, CONTINUED 5/9/2014 Location on Building Department Plans I Notes Specific System Requirements NA C403.4.2 & C403.2.12 NA C403.4.2.1 NA NA C403.4.2.2 C403.4.5 Variable VAV fan sensors VAV fan setpoint flow control - fans static pressure static pressure Indicate fans requiring variable flow control and method Indicate sensor locations on plans; duct branch include at least one sensor per major VAV systems serving multi - zones Indicate fan system static pressure pressure Indicate supply air systems serving VAV, method of primary air control, taken setpoint based on zone requiring most multiple zones that are required to be and zones served; note exceptions NA C403.4.5.4 NA NA C403.4 C403.4.7 NA C403.4.3 VAV system supply air reset Large capacity cooling systems Indicate controls that automatically reset supply air temp in response to loads Hot gas bypass limitation Large capacity boiler systems Indicate method of multi -stage or variable control for building cooling system capacity > 300 tons Indicate cooling equipment unloading or capacity modulation method Indicate mufti -stage or modulating burner for single boilers > 500,000 btuh NA C403.4.3 NA NA NA NA NA NA NA NA NA C403.4.3.5 C403.4.2 & C403.4.3.6 C403.2.12.1 & C403.4.4 C403.4.3.4 C403.4.3.2 C403.4.3.3.1 C403.4.3.3 C403.4.3.3.3 C403.4.6 NA C403.5 NA C403.5 / 6 Boiler sequencing Chiller / boiler plant pump isolation Variable flow control - pumps Variable flow control - coolinq towers Indicate automatic controls that sequence operation of multiple boilers Indicate capability to automatically reduce overall plant flow and shut-off • flow through chillers & boilers when not in use Indicate pumps requiring variable flow control & method Hydronic system part load controls Two -pipe changeover systems Water loop heat pump - deadband Water loop heat pump - heat rejection Water loop heat pump - isolation Condenser water heat recovery Cooler / freezer - anti -sweat heaters Indicate cooling tower fans requiring variable flow control and method Indicate heating & chilled water systems have the capability to automatically reset supply water temp AND reduce flow by ?50% for systems > 300,000 Indicate deadband, heating/cooling mode scheduling and changeover temperature range Indicate capability of central equipment to provide min. 20°F water supply temp deadband between heat rejection and heat addition modes Provide heat exchanger that separates cooling tower and heat pump loop in Climate Zone 5 Indicate 2-way isolation valve on each heat pump and variable flow control for systems with total pump power > 10 hp Indicate system provided to pre -heat service water and efficiency Cooler / freezer - evaporator and condenser fans Indicate w/sf & control method for walk-in cooler/freezer door anti -sweat heaters Indicate motor type for evaporator and condenser fans < 1 hp SERVICE WATER HEATING Service Water Systems YES YES C404.2 C404.3 Water -heating equip min. efficiency Temperature controls Provide equipment schedule or complete MECH-SUM table with type, capacity, efficiency, test standard (or other efficiency source) Indicate temperature controls have required setpoint capability NA NA C404.4 C404.5 NA C404.6 Heat traps Insulation under water heater Service water piping insulation Indicate piping connected to equipment have heat traps on supply & discharge Indicate R-10 insulation under tank P520 P110 Indicate R-value of insulation on piping; note exceptions taken NA C404.7 / 8 NA C404.9 Circulation systems and heat trace shut-off Group R-2 service hot water meters Pools & In -Ground Permanently Installed Spas Indicate shut-off capability based on occupancy and periods of limited demand Indicate method of usage metering for dwell. units served by central HW system NA C404.10.1 Pool heating equip min. efficiency Provide equipment schedule or complete MECH-SUM table with type, capacity, efficiency, test standard (or other eff. source); heat pump heaters COP NA NA C404.10.1 / 2 C404.10.3 Pool heater on / off controls Pool covers Indicate automatic on/off control based on scheduling & accessible on/off switch on heater that operates independent of thermostat setting' or Indicate vapor retardant cover and insulation rating as required NA C404.10.3 Pool assembly insulation Indicate rating of insulation on sides and bottom of pools heated to > 90°F NA C404.10.4 Heat recovery Indicate method, exhaust air temperature reduction and recovered energy use PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0103 DATE: 05/14/2014 PROJECT NAME: LULULEMON SITE ADDRESS: 21 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: Building Division Public Works Ll: Fire Prevention Structural p:w\ t `A- be I1 ` l 1 !Al Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 05/15/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) DUE DATE: 06/12/14 Approved with Conditions Y Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 EVERGREEN REFRIGERATION T r C Page 1 of 3 411.114 Washington State Department of Labor & Industries EVERGREEN REFRIGERATION LLC Owner or tradesperson PATTON, RODGER Principals PATTON, RODGER, PARTNER/MEMBER PATTON, MATTHEW, PARTNER/MEMBER Patton, Adam, PARTNER/MEMBER Patton, Douglas, PARTNER/MEMBER EVERGREEN REFRIGERATION LLC, PARTNER/MEMBER PATTON, DAVID, PARTNER/MEMBER (End: 01/21/2014) Doing business as EVERGREEN REFRIGERATION LLC WA UBI No. 602 512 953 727 S KENYON ST SEATTLE, WA98108 206-763-1744 KING County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. EVERGRL954R2 Effective — expiration 01/06/2006— 01/06/2016 Bond Merchants Bonding Co (Mutual) Bond account no. WA15097 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 12/15/2011 01 /01 /2012 Expiration date Until Canceled TRAVELERS CAS & SURETY CO $12,000.00 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602512953&LIC=EVERGRL954R2&SAW= 08/13/2014 MECHANICAL SYMBOLS NOTE: THIS USED ON IS A MASTER LEGEND AND NOT• ALL SYMBOLS, ETC. ARE NECESSARILY THE DRAWINGS PIPING DRAIN. (co) CD CONDENSATE CONDENSATE DRAIN (ACD) ACD RL AUXILIARY • REFRIGERANT LIQUID (RL) DISCHARGE (HOT GAS) (RD) RD REFRIGERANT REFRIGERANT (RS) RS SUCTION HEATING HOT WATER SUPPLY (HWS) HWS HEATING HOT WATER RETURN (HWR) HWR CWS CHILLED WATER SUPPLY (CWS) -CWR WATER RETURN . CHILLED (CWR) HEAT PUMP SUPPLY HS • (HS) HEAT RETURN HR PUMP (HR) LOW PRESSURE STEAM, SUPPLY (LPS) LPS PRESSURE STEAM CONDENSATE (LPC) LPC LOW • EXISTING PIPING TO BE REMOVED EXISTING PIPING TO REMAIN •OF FLOW I► it DIRECTION BALL VALVE At CONTROL VALVE THREE-WAY CONTROL VALVE • SHUTOFF VALVE • r.l VALVE CHECK • VALVE WITH PRESSURE PORTS r1 BALANCING DUTY VALVE WITH PRESSURE PORTS i :TRIPLE • - METER 17i WATER STRAINER !At c SOLENOID .VALVE PRESSURE GAUGE I THERMOMETER -P AND TEMPERATURE TEST PLUG PRESSURE UNION ---1--- FLANGE CONNECTION v ELBOW- UP 0 • ELBOW DOWN • TEE UP ioi TEE DOWN c • REDUCER HVAC EQUIPMENT & DUCTWORK NOTE: ALL DUCT, DIMENSIONS SHOWN ON DRAWINGS ARE INSIDE • DIMENSIONS. • FOR SEE SECTION 15250 OF THE SPECIFICATION DUCTWORK TO RECEIVE INSULATION OR LINER. EXISTING DUCTWORK OR EQUIPMENT TO REMAIN 4 EXISTING DUCTWORK OR EQUIPMENT TO BE REMOVED "Tip.BRANCH DUCT WITH 45' RECTANGLE -ROUND BRANCH . FITTING AND MANUAL VOLUME DAMPER • Jr 4 ELBOW WITH TURNING VANES N IN RETURN, EXHAUST, OR OUTSIDE AIR DUCT UP N • IN RETURN, EXHAUST, OR OUTSIDE AIR DUCT DOWN T NI X SUPPLY AIR DUCT UP x X SUPPLY AIR DUCT DOWN 0EQUIPMENT. WITH FLEXIBLE DUCT CONNECTION 10" CSD-1• 300 CFM NECK SIZE, TYPE, CFM OF SUPPLY DIFFUSER OR REGISTER Jr L Jr MANUAL VOLUME DAMPER > 1 SQUARE TO ROUND TRANSITION DUCT MOUNT ) SMOKE DETECTOR RD (SD=SUPPLY/RD=RETURN) • Fp FIRE DAMPER FIRE SMOKE DAMPER • VD VOLUME DAMPER MD MOTORIZED DAMPER O TEMPERATURE SENSOR C)- THERMOSTAT ABBREVIATIONS AFF ABOVE FINISHED FLOOR • BAS BUILDING AUTOMATION SYSTEM BD BACKDRAFT DAMPER • CFM CUBIC FEET PER MINUTE DDC DIRECT DIGITAL CONTROL DX • DIRECT EXPANSION • . EA EXHAUST AIR FFA FROM FLOOR ABOVE FFB • FROM FLOOR BELOW GPM • GALLONS PER MINUTE IN WC INCHES OF WATER COLUMN MAX . MAXIMUM MBH. 1000 BTU PER HOUR MC MECHANICAL CONTRACTOR - MIN • MINIMUM • NC NOISE CRITERIA OA OUTSIDE AIR RA • RETURN AIR - SA SUPPLY AIR SD- SMOKE DUCT DETECTOR TFA TO FLOOR ABOVE - TFB TO FLOOR BELOW • TYP TYPICAL UNO UNLESS NOTED OTHERWISE W/ WITH W/O WITHOUT STANDARD MOUNTING HEIGHTS MECHANICAL . (AFF, AFG, UNLESS NOTED OTHERWISE) THERMOSTATS (USER ADJUSTABLE)(TOP OF DEVICE) 48" CONTROLS (TOP OF DEVICE) - 48" • ANNOTATION 0 MECHANICAL PLAN CALLOUT ® MECHANICAL EQUIPMENT DESIGNATION (CONTRACTOR FURNISHED AND 0 INSTALLED UNLESS NOTED OTHERWISE) S • CONNECTION POINT OF NEW WORK TO EXISTING 0 DETAIL- REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER LOWER • ® NUMBER INDICATES SHEET NUMBER. Ik Iv SECTION CUT DESIGNATION r' AHU-1 SD-1 18X8 250 14"0 L SD-1 18X8 500 SD-1 18X8 400 SEPARATE. PERMIT REQUIRED OR: glkilachanical Electrical IN Plumbing tXGas. Piping City of Tukwila BUILDING DIVISION 14"0 NOTE: REFER TO SHEET A122 FOR DUCT LOCATION DIMENSIONS. r_- - -1 (") u �--- -- 1 F. 11 ALI SD--; y 18X8' 450 r SD-1 18X8 450 SD-1 1 8X8 400 20"0 RG-1 22X22 NOTE: THE OWNER RESERVES THE RIGHT TO CHECK CONSTRUCTION COMPLIANCE WITH PLANS AND SPECIFICATIONS. SHOULD THE OWNER FIND CORRECTIVE WORK NECESSARY, HE WILL NOTIFY CONTRACTOR OF SUCH WORK IN WRITING AND EXPECT COMPLIANCE PERFORMED WITH DUE DILIGENCE. IF ANY CORRECTIVE WORK IS DEEMED TO BE NECESSARY, THE COST OF REINSPECTIONS WILL BE BORNE BY THE CONTRACTOR. IF WORK IS REQUIRED BY OWNER IN ORDER TO IMPROVE, CHANGE OR CORRECT AIR CONDITIONING OPERATIONAL CONDITIONS DUE TO: PART MALFUNCTION, WARRANTY OR OTHER INABILITY TO PROVIDE THE COMFORT CONDITIONS REQUIRED BY THE STORE, CONTRACTOR SHALL BE DIRECTED BY OWNER TO ADDRESS THIS WORK IN A TIMELY MANNER.. IF IT BECOMES EVIDENT THAT THE CONTRACTOR CAN NOT ACCOMPLISH THE TASK, THEN AFTER 72 HOURS OF WRITTEN NOTICE, THE OWNER MAY AT HIS DISCRETION TAKE OVER SUCH WORK AND BACK CHARGE THE CONTRACTOR FOR ANY CORRECTIVE WORK THAT WAS REQUIRED DUE TO LACK OF PERFORMANCE, WORKMANSHIP AND/OR ADHERENCE TO PLANS AND SPECIFICATIONS. ROOF NOTE: DO NOT ATTACH ANYTHING DIRECTLY TO THE UNDERSIDE OF THE DECK. VERIFY ALL CONDITIONS IN THE FIELD PRIOR TO BIDDING. VERIFY EXACT REQUIREMENTS PRIOR TO COMMENCING ANY WORK. 10 SD-3. '0 10"0 250 SD- 0„03 1 250 firy 0 1_ L• S0--3 10"0 t250 JI Li SD-3 10"0 250 20"0 RG-1 22X22 RG-1 22X22 SD-2 0 100 O MECHANICAL FLOOR PLAN SCALE: 1/4" = 1'-0" REVISIONS No changes shall be rnade to.th gCar7P Of work without prior approv ' of Tukwila Building Divisior r4O Revisions ys ncludeladdtional plan rev'uire a news',c, "'' I j andmay I- SD-1 18X8 200 • SD-1 18X8 200 TG-1 12X12 AHU-1 co 00 0© Roll I 4 VERIFY ALL CONDITIONS IN FIELD IT IS THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR TO VISIT THE JOB SITE TO FAMILIARIZE HIMSELF WITH MAJOR ITEMS SUCH AS STRUCTURAL ELEMENTS, PLUMBING LOCATIONS, ELECTRICAL RUNS AND POINTS OF CONNECTION TO EXISTING DUCT SYSTEMS. ADDITIONALLY, MECHANICAL CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND DIMENSIONS OF SUCH ITEMS AS HVAC EQUIPMENT, DUCTWORK, . ETC. PRIOR TO COMMENCING ANY WORK. ALL HVAC WORK TO BE PERFORMED IN COMPLIANCE WITH LOCAL CODES AND LANDLORD CRITERIA. NOTE: INFORMATION ON THIS SHEET PERTAINING TO THE EXISTING MECHANICAL SYSTEMS IS BASED ON RECORD DRAWINGS AVAILABLE AT THE TIME OF DESIGN. FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY ARCHITECT AND ENGINEER IMMEDIATELY IF ANY DISCREPANCIES ARE FOUND. DUCTWORK NOTE: ALL UNEXPOSED SA DUCT TO BE WRAPPED WITH FIBERGLASS INSULATION WITH VAPOR BARRIER -00 N ETR REVIEWED FOR CODE COMPLIANCE APPROVED MAY 21 2014 City of T k ila BUILDING 'SION SD-1 18X8 200 -10" SD-3 10"0 300 IIr�_1:;__ IfI 8 GN-GENERAL NOTES: 1. PRIOR TO SUBMITTING BID, VISIT THE JOB SITE AND BECOME FULLY . ACQUAINTED WITH THE EXISTING CONDITIONS OF THE PROJECT. REVIEW THE GENERAL NOTES, SPECIFICATIONS AND OTHER DRAWINGS FOR ADDITIONAL REQUIREMENTS WHICH MAY NOT BE SPECIFICALLY CALLED OUT IN THIS PORTION OF THE CONSTRUCTION DOCUMENTS. NOTIFY ARCHITECT, ENGINEER`.` AND/OR OWNER OF CONFLICTS OR. DISCREPANCIES PRIOR TO SUBMISSION OF BID. 2 EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND SITE VISITS AND MAT NOT. REFLECT EXACT "AS -BUILT" CONDITIONS. FIELD VERIFY EXISTING CONDITIONS PRIOR TO', SUBMITTING FINAL BIDS. COORDINATE NEW WORK AND DEMOLITION WITH OTHER DISCIPLINES AND EXISTING CONDITIONS PRIOR TO CONSTRUCTION. 3. COORDINATE THE INSTALLATION OF THE MECHANICAL SYSTEMS .WITH OTHER TRADES TO ENSURE A NEAT AND ORDERLY INSTALLATION. COORDINATE INSTALLATION OF DUCTWORK AND PIPING TO AVOID CONFLICTS WITH ELECTRICAL PANELS, . LIGHTING FIXTURES, ETC. 4. AVOID DAMAGING EXISTING SURFACES AND EQUIPMENT TO REMAIN FOR NEW INSTALLATION DURING WORK. REPAIR DAMAGE CAUSED DURING CONSTRUCTION AT NO EXTRA COST TO THE OWNER. 5. ALL MECHANICAL EQUIPMENT SHOWN ON THE MECHANICAL PLANS SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR UNLESS OTHERWISE NOTED. 6 NEW MECHANICAL EQUIPMENT AND DUCTWORK ARE SHOWN AT APPROXIMATE LOCATIONS. FIELD MEASURE ,:FINAL DUCTWORK LOCATIONS PRIOR TO FABRICATION AND MAKE ADJUSTMENTS AS REQUIRED TO FIT THE DUCTWORK WITHIN THE AVAILABLE SPACE. VERIFY THAT FINAL EQUIPMENT LOCATIONS MEET MANUFACTURER'S RECOMMENDATIONS REGARDING SERVICE CLEARANCE AND PROPER AIRFLOW CLEARANCE AROUND EQUIPMENT. 7. INSTALL DUCTWORK PARALLEL TO BUILDING COLUMN LINES UNLESS OTHERWISE SHOWN OR NOTED. 8. OVERHEAD HANGERS AND SUPPORTS FOR EQUIPMENT AND DUCTWORK SHALL BE FASTENED TO BUILDING JOISTS OR BEAMS. DO NOT ATTACH HANGERS AND SUPPORTS TO THE ABOVE FLOOR SLAB OR ROOF. COORDINATE LOCATION OF EQUIPMENT SUPPORTS WITH LOCATION OF EQUIPMENT ACCESS PANELS/DOORS TO ENABLE SERVICE OF EQUIPMENT AND/OR FILTER REPLACEMENT. 10. SEAL PENETRATIONS THROUGH THE BUILDING COMPONENTS IN ACCORDANCE WITH THE CONTRACT SPECIFICATIONS. FIREPROOF PENETRATIONS THROUGH FIRE RATED COMPONENTS IN ACCORDANCE WITH U.L. REQUIREMENTS. 11. COORDINATE THE EXACT MOUNTING SIZE AND FRAME TYPE OF DIFFUSERS, REGISTERS AND GRILLES WITH THE SUPPLIER TO MEET THE CEILING, WALL AND DUCT INSTALLATION REQUIREMENTS. 12. ADJUST LOCATION OF CEILING DIFFUSERS, REGISTERS AND GRILLES AS REQUIRED TO ACCOMMODATE FINAL CEILING GRID AND LIGHTING LOCATIONS. BRANCH DUCTWORK TO AIR OUTLETS SHALL BE SAME SIZE AS OUTLET NECK SIZE UNLESS OTHERWISE NOTED. 13. PROVIDE A NEW SET OF AIR FILTERS IN UNITS PRIOR TO TESTING, ADJUSTING AND BALANCING AND BEFORE TURNING SYSTEM(S) OVER TO OWNER. 14. ALL ROOF PENETRATIONS SHALL BE PERFORMED BY A LANDLORD APPROVED CONTRACTOR TO MAINTAIN WARRANTIES. 15. TENANT SHALL LOCATE ANY ROOF TOP VENTS A MINIMUM OF 10' AWAY FROM ANY ADJACENT ROOFTOP UNIT. 16. FIELD VERIFY EXISTING CONDITIONS AND THAT SPACE CONFORMS TO APPROVED LEASE OUTLINE DRAWING, AS APPROVED .WITH LEASE AGREEMENT. 17. TENANT SHALL BE RESPONSIBLE FOR MEETING ALL APPLICABLE CODES AND OBTAINING ALL JURISDICTIONAL APPROVALS. 18. ANY EXISTING HVAC UNITS NOT TO BE REUSED BY TENANT SHALL BE REMOVED AND DISCARDED BY TENANT G.C. AND ROOF PATCHED IF REQUIRED. -TG-1 12X12 MECHANICAL PLAN KEYNOTES: FILE COPY Potmtt No. M\ 11 OW i Plan review approval Is subject to errors and omissions. Approval of construction documents does not authorize 6. the violation of any adopted code or ordinance. Receipt 7. of approved Fed Copy Andaman Isacknowledged: 8. BY 4T, Date. I r (1,4 City Of Adorns BUILDING DIVISION 1. ROUTE 8" EXHAUST DUCT UP THROUGH ROOF AND TERMINATE WITH GOOSENECK MIN 24" ABOVE ROOF OR CONNECT TO EXISTING BUILDING EXHAUST SYSTEM. ALL ROOF WORK TO BE PERFORMED BY LANDLORD'S DESIGNATED ROOFING CONTRACTOR AT THE OWNER'S EXPENSE. 2. G.C. PROVIDED -HONEYWELL THERMOSTAT, MODEL VISIONPRO TB8220. ALL WIRING, ETC. SHALL BE COORDINATED WITH ELECTRICAL CONTRACTOR AND ARCHITECT PRIOR TO INSTALLATION. FINAL CONNECTION SHALL BE MADE BY THE G.C. - COORDINATE WITH MALL OPERATIONS DIRECTOR. 3. G.C. PROVIDED REMOTE SENSOR. MOUNT OUT OF DIRECT LIGHT AT 48" ABOVE FINISHED FLOOR. ALL WIRING, ETC. SHALL BE COORDINATED WITH ELECTRICAL CONTRACTOR AND ARCHITECT PRIOR TO INSTALLATION. FINAL CONNECTION SHALL BE MADE BY THE G.C. - COORDINATE WITH MALL OPERATIONS DIRECTOR. 4. CONTRACTOR SHALL UNDERCUT DOOR 1" FOR AIR FLOW TO EXHAUST FANS. 5. COORDINATE INSTALLATION OF EQUIPMENT, DUCTWORK AND PIPING WITH ALL TRADES. DO ROUTE DUCTWORK OR PIPING OVER ELECTRICAL PANELS. PROVIDE 4.5 SOFT OF FREE AREA OPENING IN WALL ABOVE CEILING FOR AIR TRANSFER. PAINT NEW EXPOSED DUCTWORK TO MATCH FINISHED CEILING. MOUNT TRANSFER GRILLE AS HIGH AS POSSIBLE. 9. EXISTING LANDLORD PROVIDED 12.5 TON AHU IS SUPPLY WITH 700 CFM OUTDOOR AIR. TO REMAIN. BALANCE TO 5000 CFM 10. EXTEND RETURN AIR DUCT FULL SIZE OF AHU INTO SPACE. 1 /2" x 1/2" GALVANIZED HARDWARE CLOTH. END OPEN AND COVER WITH RECEIVED AIR DISTIBUTIOI\I (BASED DEVICE SCHEDULE ON TITUS) MAY 142014 PERMIT CENTER NOTES: 1. SYMBOL KEY - FIRST LETTER: S-SUPPLY R-RETURN E-EXHAUST T-TRANSFER. SECOND LETTER: D-DIFFUSER R-REGISTER G-GRILLE 2. BORDER STYLE - REFER TO REFLECTED CEILING PLAN 3. DAMPERS - OPERABLE FROM FACE - OB: OPPOSED BLADE ROB: RADIAL OPPOSED BLADE B: BUTTERFLY TAG MODEL SIZE MOUNTING MATERIAL ACCESSORIES REMARKS FACE NECK SIDE- WALL CEILING DUCT FLOOR STEEL ALUM. DPR. EQUAL GRID FIRE DPR. SD-1 TITUS S300FS 18"x8" - o 0 OB GRILLES TO BE ROTATED 30 DEGREES ON DUCT, AIMED TOWARD FLOOR. SD-2 TITUS 250 - SIDEWALL 12 x8 8 o o ROB 2-WAY FLOW. OPPOSED BLADE DAMPER SD-3 TITUS TDC 24"x24" 10"0 0 o ROB CONTRACTOR TO PROVIDE ANY ROUND DUCT NECK TRANSITIONS. SD-4 TITUS TDC 14"x14" 6"0 0 o ROB TG-1 TITUS 355RL 12x12 14"x14" 12"x12" o o - RG-1 TITUS 355RL 20x20 24"x24" 22"x22" o o - 0 i 0 "3 RG-2 TITUS 355RL 20x20 24"x24" 22"x22" o 0 0 - .....- NO MEP Engineer of Record Randall A. Nelson, P. E. 14817 West 95th Street Lenexa, Kansas 66215 Phone 913 322 5150 4 F NO. I DATE I DESCRIPTION awAs4r ti`c' "d„A 4, 'r'll - g) E ,a`.; 43448 9 . r l'9; Air 5' EXPIRES 9/21/2015 MECHANICAL FLOOR PLAN LULULEMO\ ATHLETICA CO\STUCTO\ STA\DADS 21 SOUTHCENTER, SUITE 748 TUKWILA, WA 98188 ISSUE FOR SD 03/24/14. ISSUE FOR DD-LLL 04/15/14 ISSUE FOR DD-LLD 04/18/14 ISSUE FOR CD-LLL 05/01/14 ISSUE FOR CD -LLD 05/01/14 ISSUE FOR PERMIT xx/xx/xx ISSUE FOR BID xx/xx/xx Scale` AS INDICATED Date: 3/7/14 Drawn By. DP/DB Checked By. CF Job Number: 14 2.0115 Drawing: 31,, 1/4", 21 1/4", 19 1 /4" OR 1; /4" OUTSIDE DIMENSION 23 19", 17" OR 11 " NSIDE DIMENSION 24", 20", 18" OR 12" NOTE: ROUGH -IN OPENING SIZES: NOMINAL 12"x 12" = 12 1/2"x 12 1/2" NOMINAL 24"x 24" = 24 1 /2"x 24 1/2" NOMINAL 24"x 12" = 24 1/2"x 12. 1/2" NOMINAL 18"x 18" = 18 1/2"x 18 1/2" NOMINAL 20"x 20" = 20 1/2"x 20 1/2" 25 1/4", 21 1/4", 19 1/4" OR 13 1/4" 1 1 /2"-- 1 1/8" "C" CHANNEL REINFORCING BY. G.C. AROUND OPENING. MOUNTING SCREW FIELD INSTALLED, DRYWALL CEILING STEEL MOUNTING FRAME DRYWALL MOUNTING FRAME SCHEMATIC NO SCALE METAL GAUGE FOR DUCTWORK TO BE AS FOLLOWS: ROUND DUCT 3 TO 19 INCHES TO BE 26 GAUGE RECTANGULAR DUCT UP TO 12 INCHES WIDE TO BE 26 GAUGE RECTANGULAR DUCT 13 TO 30 INCHES WIDE TO BE 24 GAUGE. RECTANGULAR DUCT ABOVE 30 INCHES WIDE TO BE 22 GAUGE. STEEL STRAP HANGER DUCTWORK SELF -TAPPING, SHEET METAL SCREW HANGER SPACING: DUCT FACE AREA FROM 0 TO 4 SQ. FT. HANGERS 98" 0.C. MAX DUCT FACE AREA FROM 4 TO 10 SQ. FT. HANGERS 72" 0.C. MAX DUCT FACE AREA FROM 10 AND GREATER HANGERS 48" 0.C, MAX WHERE DUCTS ARE LESS THAN 2 SQ. FT. IN FACE AREA, HANGERS SHALL BE NOT LESS THAN 1"x1/16" STRAP STEEL, WHERE DUCT ARE GREATER THAN 2 SQ. FT. IN FACE AREA. HANGERS SHALL BE NOT LESS THAN 1 "x1 /8" STRAP STEEL. WHERE DUCT ARE 8 SQ. FT. IN FACE AREA. HANGERS SHALL BE BRACED BY 1 "x1"x1 /8" STEEL ANGLES ALL AROUND, SPACED NO MORE THAN FOUR FEET ON CENTERS. WHERE DUCTS ARE OVER 48" WIDE. THE HANGERS SHALL BE BROUGHT DOWN UNDER THE DUCT SIDES 4" AND FASTENED TO THE BOTTOM. DUCT SUPPORT SCHEMATIC NO SCALE ANGLE; RIVETED OR WELDED AS REQD INSECT SCREEN SEE NOTE 2. WATER PROOF SEALANT SEE NOTE 1. PREFABRICATED INSULATED CURB WITH TREATED WOOD NAILER INSULATION TWO PIECE GALVANIZED COUNTER FLASHING AND CURB PROVIDE 1" CLEAR OPENING AROUND DUCT TO ALLOW FOR DUCT MOVEMENT NOTES; 1. WATER PROOF ALL SEAMS AND JOINTS. 2. MECHANICALLY ATTACH SCREEN TO DUCT. GGOOSENECK DETAIL NO SCALE ALL DUCT LINER TRANSVERSE EDGES TO BE COATED W/ ADHESIVE IN ACCORDANCE W/ SMACNA STANDARDS. (TYP.) TAPE DOWN EXTERNAL INSULATION. FASTEN W/ MIN. (3) SHT. MTL. SCREWS, SEAL W/ DUCT TAPE AND MASTIC. ROUND RIGID DUCT. 1-1/2" WRAPPED INSULATION. - FLANGED AND GASKETED JOINT OR DUCT CONNECTION AND RE-INFORCEMENT IN ACCORDANCE W/ SMACNA 2" W.G. CLASS, SEAL NON-GASKETED TRANS -VERSE JOINTS IN ACCORDANCE W/ SMACNA CLASS "C (TYP.) CONICAL OR BELLMOUTH SPIN -IN FITTING, SEAL AIRTIGHT W/ MASTIC. GTYPICAL ROUND DUCT TAKE -OFF DETAIL NO SCALE TO S.A. MAIN INSULATED ROUND DUCT FLEXIBLE CONNECTION (MAX. 5 FT.) THERMAL INSULATING BLANKET WHERE REQUIRED. • SUPPLY AIR DIFFUSER STRAP CLAMP (TYPICAL) FINISHED DRYWALL CEILING ODIFFUSER MOUNTING DETAIL NTS RETURN/SUPPLY AIR DUCT-� RETURN TUBE SMOKE DETECTOR ALSO MAY BE LOCATED WITHIN UNIT SAMPLING TUBE GSMOKE DETECTOR DETAIL NTS VIBRATION ISOLATORS RUBBER -IN -SHEAR EXHAUST DUCT BY MECH. CONTR. (VERIFY ROUTING AND SIZES IN FIELD) TARAFT DAMPER TYP. EXHAUST TOILET EXHAUST FAN DETAIL NTS REVIEWED FOR CODE CQMPLIANCE APPROVED MAY 21 2014 City of Tukwila BUILDING DIVISION «AIR FLOW OVERSIZE DUCT COLLAR TO FIT REGISTER FLANGE • AIR FLOW 45* ENTRY COLLAR SUPPLY AIR REGISTER WITH INTEGRAL VOLUME DAMPER DUCT MOUNTED REGISTER DETAIL NO SCALE VECHA\ICAL RESPONNSI3ILITY SCHEDULE ITEM FURNISHED BY INSTALLED BY REUSE EXISTING N/A REMARKS TENANT LANDLORD CONTR. LANDLORD CONTR. AIR HANDLING UNITS o 0 STRUCTURAL SUPPORTS FOR AHU AS REQUIRED o 0 CONDENSING UNITS o 0 CURB AND/OR STRUCTURAL SUPPORTS FOR COND. UNITS AS REQUIRED a o ROOF TOP UNITS o ROOF CURB AND/OR CURB ADAPTER FOR RTU AS REQUIRED o STRUCTURAL SUPPORTS FOR RTU AS REQUIRED. o DIFFUSERS AND GRILLES o o U.O.N. DIFFUSERS/GRILLES FIRE DAMPERS o WALL FIRE DAMPERS AND/OR COMBINATION SMOKE/FIRE DAMPERS o LOW PRESSURE DUCTWORK o o U.O.N. HIGH/MEDIUM PRESSURE DUCTWORK o TEMPERATURE CONTROL SYSTEM o 0 RELIEF AIR/MAKE UP AIR MOTOR OPERATED DAMPERS o RELIEF AIR/MAKE UP AIR MOTOR OPERATED DAMPER ACUATORS o SMOKE DETECTOR(S) IN RETURN AND/OR SUPPLY AIR DUCT 0 ZONE DAMPERS o UNIT/BASEBOARD HEATER(S) o OUTSIDE AIR INTAKE LOUVER o o RELIEF AIR FAN OR HOOD o TOILET EXHAUST FAN(S) o 0 TOILET EXHAUST DUCTWORK WALL OR ROOF CAP o o AIR BALANCE REPORT o AABC OR NEBB CERTIFIED AS -BUILT DRAWINGS o SPRINKLER PIPING AND HEADS o 0 GENERAL NOTE REFERENCE. ALL ITEMS LISTED HERE ARE SPECIFIED AND DETAILED ENCOUNTERS ITEMS THAT ARE CONTRADICTORY THEN IT IS HIS MANAGER SO THAT THESE ITEMS CAN BE CLARIFIED CONTROL OVER ALL OTHER INFO. THIS SCHEDULE 1S INTENDED AS A "QUICK" ON THESE DRAWINGS. IF THE CONTRACTOR RESPONSIBILITY TO INFORM TENANT'S CONSTRUCTION FOR THE CONTRACTOR. NOTE: LEASE PROVISIONS FAN SCHEDULE MARK MANUFACTURER MODEL MOUNTING CFM ESP (IN) MIN. HP AMPS ELECTRICAL VOLTS/PH DISC. TYPE NOTE EF-1 BROAN QTRE080FLT CEILING 80 0.25 FRAC 0.9 120/1 SWITCH A-D EF-2 BROAN QTRE080FLT CEILING 80 0.25 FRAC 0.9 120/1 SWITCH A-D NOTES: A. PROVIDE WITH BACK DRAFT DAMPER. B. EXHAUST FAN SHALL BE INTERLOCKED WITH LIGHT SWITCH. C. UNIT IS COMBINATION FAN/LIGHT. FURNISH 42 FLUORESCENT LAMP. D. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. I'-k0103 RECEIVED CITY OF TUKWILA MAY 1 \4 2014 PERMIT CENTER MEP Engineer of Record Randall A. Nelson, P. E. 14817 West 95th Street Lenexa, Kansas 66215 Phone 913 322 5150 i N 1 a 4 N U z 0 a gl , z .Io yL ,tip. ,e C) OP tO 4. 1, ,,, G iti A. N ' Sitt , 90 `0 ' 43448 ,9 I.. EXPIRES 9/21/2015 MECHANICAL SCHEDULES AND DETAILS LULULEMO\ ATHLETICA CO\STUCTO\ STANDA-DS 21 SOUTHCENTER, SUITE 748 TUKWILA, WA 98188 ISSUE FOR SD 03/24/14 ISSUE FOR DD—LLL 04/15/14 ISSUE FOR DD—LLD 04/18/14 ISSUE FOR CD—LLL 05/01/14 ISSUE FOR CD —LLD 05/01/14 ISSUE FOR PERMIT xx/xx/xx ISSUE FOR BID xx/xx/xx Scale: AS INDICATED Date: 3/7/14 Drawn By:DP/DB Checked By. CF Job Number: 1 42.011 5 Drawing: DMSION 15 - MECHANICAL SECTION 15000 MECHANICAL GENERAL PROVISIONS A. GENERAL CONDITIONS 1. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATION SECTIONS ARE A PART OF THIS CONTRACT AND APPLY TO THIS AND THE OTHER SECTIONS OF DIVISION 15. 2. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE ENTIRE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL OTHER TRADES. 3. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING HIS SUBCONTRACTORS WITH A FULL SET OF BID SET DOCUMENTS (INCLUDING SPECIFICATIONS) AND THE COORDINATION OF HIS WORK AND INSPECTIONS AND THE WORK AND INSPECTIONS OF HIS SUBCONTRACTORS WITH ALL OTHER TRADES ON SITE CONFORMING TO THE GENERAL CONTRACTOR'S TIME SCHEDULE. 4. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTING HIS BID TO DETERMINE CONDITIONS AFFECTING THE WORK. BIDS SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF WORK. 5. WHEN USED, THE TERM "PROVIDED BY CONTRACTOR" SHALL BE INTERPRETED AS MEANING "FURNISHED AND INSTALLED" WITH THE EXCEPTION WHERE ITEMS ARE "PROVIDED BY TENANT" WHICH MEANS "FURNISHED ONLY" (INSTALLED BY CONTRACTOR), EXCEPT AS SPECIFICALLY NOTED OTHERWISE. B. GENERAL REQUIREMENTS 1. THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE AND FULLY FUNCTIONAL MECHANICAL SYSTEM AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH THE LANDLORD, AS REQUIRED. FIELD VERIFY THE EXACT TYPE, SIZE AND LOCATION, ETC. OF EXISTING PIPE AND DUCTS IN THE TENANT SPACE PRIOR TO BID. 2. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE PROVIDED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK, AND WHICH IS USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE PROVIDED AS PART OF CONTRACT. 3. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE CONTRACTOR IS STILL RESPONSIBLE FOR PROVIDING THE SYSTEM AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. ALL MECHANICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING, AND REPAIRING. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUFFICIENT ACCESS TO ALL EQUIPMENT FOR SERVICE. IN OR RE DRILLING,CHASING T R THE CONTRACTOR SHALL G, CORE LL DO ALL CUTTING, THISDIVISION. IR FORUNDER D CHANNELING AND PATCHING REQUIRED ANY WORK CUTTING SHALL HAVE PRIOR APPROVAL BY THE TENANT'S CONSTRUCTION MANAGER AND THE LANDLORD. PATCHING SHALL MATCH, FINISH OFSURROUNDING AREA. C. CODES 1. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING GOOD ENGINEERING PRACTICES. ALL WORK SHALL CONFORM TO THE LANDLORD'S CRITERIA, THE COUNTRY'S AND LOCAL CODES AND ORDINANCES, SAFETY AND HEALTH CODES, NFPA CODES, ENERGY CODES AND ALL OTHER APPLICABLE CODES AND REQUIREMENTS. THE CONTRACTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. AFTER CONTRACT IS ISSUED, NO ADDITIONAL COST DUE TO CODE ISSUES SHALL BE REIMBURSED BY THE TENANT TO THE CONTRACTOR. D. LICENSES, PERMITS, INSPECTIONS & FEES 1. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, INSPECTIONS, AND FEES REQUIRED OR RELATED TO HIS WORK. 2 FURNISH TO THE TENANT'S CONSTRUCTION MANAGER ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT SUBSTANTIAL COMPLETION DATE OF PROJECT. E. DRAWINGS 1. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE MECHANICAL SYSTEMS. BECAUSE OF THE SMALL SCALE OF THE DRAWINGS, IT IS NOT POSSIBLE TO INDICATE ALL DUCT AND PIPING OFFSETS, FITTINGS AND ACCESSORIES THAT MAY BE REQUIRED. THE LAYOUT SHOWN ON THE DRAWINGS IS BASED ON A PARTICULAR MAKE OF EQUIPMENT. IF ANOTHER MAKE OF EQUIPMENT IS USED WHICH REQUIRES MODIFICATION OR CHANGE OF ANY DESCRIPTION FROM THE DRAWINGS OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE AS PART OF THIS WORK, FOR MAKING ALL SUCH MODIFICATIONS AND CHANGES, INCLUDING THOSE INVOLVING OTHER TRADES WITH THE COST THEREOF INCLUDED IN HIS BID. IN SUCH CASE, CONTRACTOR SHALL SUBMIT DRAWINGS AND SPECIFICATIONS PRIOR TO STARTING WORK SHOWING ALL SUCH MODIFICATIONS AND CHANGES. HIS PROPOSAL SHALL BE SUBJECT TO THE APPROVAL OF THE TENANT'S CONSTRUCTION MANAGER. F. EXISTING SHELL SPACE CONDITIONS 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING MECHANICAL WORK SHOWN ON THE MECHANICAL DRAWINGS AND THE MECHANICAL DEMOLITION SHOWN ON THE ARCHITECTURAL DRAWINGS. 2. THE CONTRACTOR SHALL INCLUDE, AND WILL BE HELD RESPONSIBLE FOR, THE REMOVAL OF ALL EXISTING FIRE PROTECTION, PLUMBING FIXTURES, PIPING, HVAC UNITS, REFRIGERANT RECAPTURE, EXHAUST FANS, ETC. AND ASSOCIATED ROOF CURBS NOT TO . BE REUSED ON THIS PROJECT, UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT, PIPES, DUCTWORK, AND EQUIPMENT PRIOR TO REMOVAL ROOF CURBS SHALL BE REMOVED AND THE ROOF PATCHED UNLESS NOTED FOR REUSE OR RECONFIGURATION ON PLANS. ROOF PATCHING SHALL BE PERFORMED AT THE CONTRACTOR'S EXPENSE BY A ROOFING CONTRACTOR APPROVED BY THE LANDLORD. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF (ABOVE THIS SPACE) NOT APPLICABLE TO THE NEW WORK OR PART OF THE LANDLORD'S OR ANOTHER TENANT'S ACTIVE SYSTEM MUST BE REMOVED AND ROOF/WALL/FLOOR PATCHED/REPAIRED TO MATCH EXISTING STRUCTURE. EXISTING ABANDONED PIPES, DUCTS, OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE, OR OTHERWISE INACCESSIBLE ARE TO BE CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LANDLORD OR CODES, ABANDONED PIPING AND/OR DUCTWORK MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM THE EXTENT OF DEMOLFON PRIOR TO BID AND INCLUDE IN BID PROPOSAL. 3. ACTIVE LANDLORD OR OTHER TENANT SERVICES ENCOUNTERED IN WORK SHALL BE PROTECTED AND SUPPORTED. IF EXISTING SERVICES NOT ANTICIPATED REQUIRE RELOCATION, CONTACT THE TENANT'S CONSTRUCTION MANAGER IMMEDIATELY. ALL COSTS FOR REPAIR OF DAMAGES TO ACTIVE LANDLORD OR OTHER TENANT SERVICES DURING CONSTRUCTION SHALL BE PAID FOR BY THE CONTRACTOR CAUSING THE DAMAGE. 4. TIE-INS AND MODIFICATIONS TO EXISTING LANDLORD SERVICES MUST BE DONE WITH MINIMUM INTERRUPTION OF LANDLORD OPERATION AND DURING HOURS SPECIFIED BY THE LANDLORD. THE CONTRACTOR IS RESPONSIBLE FOR CONFIRMING EXACT WORKING HOURS OF THIS WORK WITH THE LANDLORD PRIOR TO SUBMITTING HIS BID, THE CONTRACTOR SHALL INCLUDE IN HIS BID, ALL PREMIUM TIME REQUIRED TO PERFORM MODIFICATIONS DURING OTHER THAN NORMAL WORKING HOURS. ALL SUCH WORK MUST BE COORDINATED WITH THE LANDLORD. G. DISCREPANCIES IN DOCUMENTS 1. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE MECHANICAL SYSTEMS. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE THE GENERAL CONTRACTOR IN WRITING, PRIOR TO SUBMITTAL OF BID. THE GENERAL CONTRACTOR IS RESPONSIBLE TO ADVISE THE TENANT'S CONSTRUCTION MANAGER, IN WRITING, OF VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF BID. OTHERWISE, TENANT'S CONSTRUCTION MANAGER'S INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. H. TRADE NAMES AND MANUFACTURERS 1. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM STANDARD FOR THE BASE BID. MANUFACTURERS CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE SUBJECT TO APPROVAL IN WRITING BY THE TENANT'S CONSTRUCTION MANAGER PRIOR TO ACCEPTANCE. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE. I. SHOP DRAWINGS 1. SUBMIT SIX COPIES OF MATERIAL LISTS AND SHOP DRAWINGS FOR ALL EQUIPMENT AND DUCT FABRICATION DRAWINGS TO THE TENANT'S CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO ORDERING EQUIPMENT. SUBMISSIONS MUST BE EARLY ENOUGH TO ALLOW THE TENANT'S CONSTRUCTION MANAGER EIGHT WORKING DAYS FOR REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL. BE IN ACCORDANCE WITH THE GENERAL COND[ONS USING THE MANUFACTURER'S LISTED ON THE DRAWINGS. SHOP DRAWINGS SHALL INCLUDE ALL DATA THAT PERTAINS TO THE REQUIREMENTS SET FORTH ON THE DRAWINGS AND IN THE SPECIFICATIONS. THE SUBMITTAL SHALL INCLUDE BUT NOT LIMITED TO CUTS OR CATALOGS INCLUDING DESCRIPTIVE LITERATURE AND CHARACTERISTICS OF EQUIPMENT SHALL SHOW MAJOR DIMENSIONS, ROUGHING -IN DATA, CAPACITY, CURVES, PRESSURE DROP, CODE COMPLIANCE, MOTOR AND DRIVE DATA AND ELECTRICAL DATA. OBSERVE SPECIAL INSTRUCTIONS WHEN REQUIRED. SUBMITTALS SHALL BEAR THE STAMP OF THE GENERAL AND SUB -CONTRACTOR SHOWING THAT HE HAS REVIEWED AND CONFIRMED THAT THEY ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS TAKE PLACE. LACK OF SUCH CONTRACTOR'S REVIEW AND APPROVAL WILL BE CAUSE FOR REJECTION WITHOUT REVIEW BY TENANT'S CONSTRUCTION MANAGER. ' ALL SHOP DRAWINGS MUST APPEAR IN THE OPERATION AND MAINTENANCE MANUALS LEFT ON SITE AT JOB COMPLETION. 2. TENANT'S CONSTRUCTION MANAGER'S REVIEW OF SHOP. DRAWINGS OR SCHEDULES SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR ERRORS, OMISSIONS OR OTHER DEFICIENCIES OR DEVIATIONS IN THE SHOP DRAWING FROM THE CONTRACT DRAWINGS AND SPECIFICATIONS. J. RECORD DRAWINGS 1. THE CONTRACTOR SHALL MAINTAIN ONE COPY OF DRAWINGS AND SPECIFICATIONS ON THE JOB SITE TO RECORD DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS: A. B. C. LOCATION OF CONCEALED PIPING VALVES AND DUCTS. REVISIONS, ADDENDUMS, AND CHANGE ORDERS, SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, AND CONTRACTOR'S COORDINATION WITH OTHER. TRADES. EXACT ROUTING OF ALL SANITARY AND DOMESTIC WATER PIPING UNDER FLOOR. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL, THE CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. THE DRAWINGS ARE TO BE TURNED OVER TO THE TENANT. K. GUARANTEE 1. THE CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORK UNDER HIS CONTRACT AND SHALL MAKE GOOD, REPAIR OR REPLACE AT HIS OWN EXPENSE, ANY DEFECTIVE WORK, MATERIAL, OR EQUIPMENT WHICH MAY BE DISCOVERED WITHIN A PERIOD OF 12 MONTHS FROM THE DATE OF ACCEPTANCE (IN WRmNG) OF THE INSTALLATION BY THE TENANT'S CONSTRUCTION MANAGER. PROVIDE EXTENDED WARRANTIES AS SPECIFIED WITH INDMDUAL EQUIPMENT. IN CASE OF REPLACEMENT OR REPAIR OR EQUIPMENT DUE TO FAILURE WITHIN GUARANTEE PERIOD, GUARANTEE ON THAT PORTION OF WORK SHALL BE EXTENDED FOR A PERIOD OF ONE (1) YEAR FROM DATE OF SUCH REPLACEMENT OR REPAIR. L. OPERATIONS MANUALS 1, ONE COPY OF EACH OPERATION AND MAINTENANCE MANUAL FOR ALL EQUIPMENT FURNISHED ON JOB SHALL BE COLLECTED AND INSERTED IN A 3" THREE RING NOTEBOOK L INCLUDE BUT OVER TOTHETENANT, EACHSHALL AND TURNED E BINDER NOT BE LIMITED TO INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS, PAMPHLETS OR BROCHURES APPROVED SHOP DRAWINGS AND WARRANTIES OBTAINED FROM EACH MANUFACTURER OF PRINCIPAL ITEMS OF EQUIPMENT. M. SLEEVES 1. THE CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR. 2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND/OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RTV" FOAM, 3M FIRE RATED SEALANTS OR EQUAL, SO AS TO RETAIN THE FIRE RATING OF THE FLOOR OR WALL. CONFORM TO U.L. ASSEMBLY RATING OF FLOOR OR WALL 3. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL PIPING, SLEEVES SHALL BE NO. 22 U.S.G. GALVANIZED STEEL MINIMUM. 4. DUCT SLEEVES TO BE MINIMUM 14 GAUGE STEEL N. HANGERS 1. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, BANDS, C-CLAMPS WITH RETAINING CLIPS, CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK. 2. HANGERS SHALL BE FASTENED TO BUILDING STEEL CONCRETE, OR MASONRY, BUT NOT TO PIPING OR DUCTWORK. HANGING FROM METAL DECK IS NOT PERMITTED, HANGERS MUST BE ATTACHED TO UPPER CHORD OF BAR JOIST. WHERE INTERFERENCES OCCUR, IN ORDER TO SUPPORT DUCTWORK OR PIPING, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, ACCESS DOORS AND OTHER EQUIPMENT SERVICE REQUIREMENTS AND/OR OTHER TRADES. HANGER TYPES AND INSTALLATION METHODS ARE SUBJECT TO LANDLORD CRITERIA 3. HANGERS FOR ALL INSULATED PIPING SHALL BE SIZED AND INSTALLED FOR THE OUTER DIAMETER OF INSULATION. INSTALL 6" LONG SPLIT CIRCLE GALVANIZED SADDLE BETWEEN THE HANGER AND THE PIPE INSULATION. 4 HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DI -ELECTRICALLY SEPARATED FROM ONE ANOTHER. 0. ACCESS DOORS 1: FURNISH STEEL ACCESS DOORS AND FRAMES, MIN. 16" X 20" OR AS SHOWN ON DRAWINGS, TO GENERAL CONTRACTOR FOR ALL LOCATIONS WHERE NECESSARY TO PROVIDE ACCESS TO CONCEALED VALVES, AND OTHER EQUIPMENT REQUIRING SERVICE OR INSPECTION. LOCATION, TYPE, SIZE AND NUMBER AS DETERMINED BY CONTRACTOR AND APPROVED BY TENANT CONSTRUCTION MANAGER TO SUIT EQUIPMENT REQUIREMENTS. GENERAL CONTRACTOR WILL INSTALL ACCESS DOORS AND FRAMES. 2 ACCESS DOORS LOCATED IN FIRE -RATED WALLS, FLOORS, CEILING -FLOOR OR CEILING -ROOF ASSEMBLIES SHALL BE FIRE RATED, UNDERWRITER'S LABORATORIES, INC., LISTED AND LABELED: 3 ACCESS DOORS SHALL BE FLUSH TYPE, MANUFACTURED FROM NO. 14 GAUGE STEEL, COMPLETE WITH FLUSH FLANGE TYPE FRAMES MANUFACTURED FROM NO. 16 GAUGE STEEL, PROVIDED WITH ANCHORS. ACCESS DOORS SHALL BE SUITABLE FOR INSTALLATION IN WALL OR CEILING MATERIALS SHOWN IN ROOM FINISH SCHEDULES. P. ELECTRICAL MOTORS 1. FURNISH, INSTALL AND ALIGN ALL MOTORS REQUIRED FOR THIS EQUIPMENT. UNLESS THEY ARE FACTORY INSTALLED ON THE UNIT, ALL STARTERS AND ASSOCIATED WIRING AND SAFETY SWITCHES FOR SUCH MOTORS SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. STARTERS SHALL MEET ALL REQUIREMENTS AS DEFINED IN THE ELECTRICAL DIVISION OF THE SPECIFICATIONS. 2. DESIGN, CONSTRUCTION AND PERFORMANCE CHARACTERISTICS OF MOTORS SHALL CONFORM TO ALL APPUCABLE PROVISIONS OF LATEST NEMA, ANSI, ISEE STANDARDS FOR ELECTRICAL EQUIPMENT. ALL MOTORS SHALL BE SUITABLE FOR OPERATION ON VOLTAGE VARIATION OF PLUS OR MINUS 10%, 40 DEGREES C AMBIENT TEMPERATURE; HAVE A SERVICE FACTOR OF NOT LESS THAN 1.15. Q. LOW VOLTAGE (24 VOLT) WIRING 1. THE CONTRACTOR IS TO INSTALL ALL LOW VOLTAGE WIRING REQUIRED FOR HIS EQUIPMENT. THIS WORK INCLUDES ALL TRANSFORMERS AND DEVICES TO MAKE THIS A COMPLETE FUNCTIONAL SYSTEM, ALL WORK IS TO CONFORM TO THE LATEST ADDITION C.E.C. AND TO DIVISION 16 ELECTRICAL SPECIFICATIONS. ANY CONDUIT REQUIRED BY CODE OR THE LANDLORD WILL BE INSTALLED BY THE ELECTRICAL SUBCONTRACTOR. DIVISION 15 - MECHANICAL SECTION 15500 HEATING, VENTILATION, AND AIR CONDITIONING A. SCOPE OF WORK 1. THE HVAC CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL T0, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE MECHANICAL SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING:(REFER TO RESPONSIBILITY SCHEDULE FOR EXACT RESPONSIBILITIES) B. HVAC A. ROOFTOP UNITS, EQUIPMENT, AND APPURTENANCES. B. DUCTWORK, FITTINGS, DAMPERS, AND INSULATION. C. HYDRONIC PIPING AND INSULATION (AS APPLICABLE, REFER TO PLANS). D. REFRIGERANT PIPING (AS APPLICABLE, REFER TO PLANS). E. DIFFUSERS, GRILLES, AND REGISTERS. F. CURBS AND STEEL FRAMING FOR SUPPORT (AS APPLICABLE, REFER TO PLANS). G. TESTING, ADJUSTING, AND BALANCING. H. OPERATIONS MANUALS, I. TEMPERATURE CONTROLS AND RELATED DIAGRAMS. J. SEQUENCES OF OPERATION, K. CONNECTION TO ANY LANDLORD ENERGY MANAGEMENT SYSTEM. BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE HVAC SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. EQUIPMENT PRIMARY HEATING, VENTILATION AND AIR CONDITIONING UNITS. A. PRIMARY HEATING, VENTILATION, AND AIR CONDITIONING UNITS ARE TO BE BY TRANE AS SCHEDULED. ALL COMPRESSORS ARE TO INCLUDE A 5-YEAR EXTENDED WARRANTY. B. EQUALS EQUIPMENT AS MANUFACTURED BY CARRIER OR YORK ARE ACCEPTABLE. C. ALL EQUIPMENT SHALL BE COMPLETE IN EVERY RESPECT WITH ALL DEVICES, APPURTENANCES, AND ACCESSORIES PROVIDED TO MEET THE DESIGN INTENT AND OPERATION OF THE SYSTEMS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. D. EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS, ALL AIR CONDITIONING EQUIPMENT MUST HAVE A CONDENSATE DRAIN AND BE TRAPPED IN ACCORDANCE WITH MANUFACTURERS DATA. SEE DRAWINGS FOR ADDITIONAL DETAILS. E SECONDARY DRAIN PANS ARE REQUIRED TO BE INSTALLED BENEATH ALL INDOOR AIR CONDITIONING EQUIPMENT WITH THE EXCEPTION OF VAV BOXES. SECONDARY PANS ARE TO PROTECT ENTIRE UNIT. PROVIDE CONDENSATE PUMPS, AS REQUIRED. CONDENSATE SHALL BE DIRECTED TO MOP SINK OR AS SPECIFIED ON PLANS. VARIABLE AIR VOLUME BOXES (VAV) A. WHERE SHOWN ON DRAWINGS, PROVIDE VAV BOXES COMPLETE WITH CONTROLS, HEATING COILS (FANS AS REQUIRED). ALL DUCT CONNECTIONS FLEXIBLE DUCT/PIPE CONNECTIONS SHALL BE PROVIDED BY THE CONTRACTOR. 3. TOILET EXHAUST FANS A. WHERE SHOWN ON DRAWINGS, PROVIDE A TOILET EXHAUST FAN UNIT COMPLETE WITH GRAVITY BACK DRAFT DAMPERS. ALL DUCTWORK, ROOF OPENINGS AND CAPS NECESSARY TO PROVIDE A COMPLETE EXHAUST SYSTEM SHALL BE PROVIDED BY THE CONTRACTOR. REFER TO PLANS FOR APPLICABILITY. 4. BASEBOARD, CABINET, AND UNIT HEATERS A. WHERE SHOWN ON DRAWINGS, PROVIDE ELECTRIC HEATERS COMPLETE WITH ELECTRIC HEATING COIL, CONTROLS, AND INTEGRAL THERMOSTAT. 5. INLINE PUMPS A. WHERE SHOWN ON DRAWINGS PROVIDE AN PR VI INLINE CLOSE COUPLED PUMP(S), , BRONZE FITTED, PUMPS SHALL BE FURNISHED WITH BRONZE CASE WEARING RINGS, BRONZE SHAFT SLEEVE AND MECHANICAL SHAFT SEAL RATED FOR. PUMPS TO BE SO CONSTRUCTED THAT THEY MAY BE MOUNTED IN A HORIZONTAL OR VERTICAL PIPE LINE. MOTOR TO BE 1750 RPM UNLESS NOTED OTHERWISE. VIBRATION ISOLATION DEVICES A. VIBRATION ISOLATION DEVICES SHALL BE PROVIDED IN ALL SUPPORTS BETWEEN VIBRATING EQUIPMENT (FANS, ROOFTOP UNITS, AIR HANDLERS, FAN POWERED VAV BOXES, ETC.) AND STRUCTURE. B. VIBRATING EQUIPMENT HUNG FROM STRUCTURE SHALL BE ISOLATED WITH RUBBER AND SPRING DEVICES. VIBRATING EQUIPMENT SUPPORTED FROM FLOOR OR DECK SHALL BE ISOLATED WITH HOUSED SPRING MOUNT DEVICES. C. EXAMINE DEAD LOAD AND OPERATING LOAD CONDMONS WHEN SELECTING DEVICES, ADJUST FOR PROPER ALIGNMENT AND LOADING. AVOID "GROUNDING" THE ISOLATOR. D CHECK HANGER ROD SIZE FOR ALLOWABLE LOADS AT THE ISOLATING DEVICE AND AT THE UPPER AND LOWER ATTACHMENTS TO STRUCTURES, DUCTS, EQUIPMENT, ETC. E. CONSULT MANUFACTURER FOR APPLICATION DATA. 7. CURBS AND STEEL FRAMING FOR SUPPORT A. THIS CONTRACTOR WILL PROVIDE ALL NECESSARY CURBS AND STEEL FRAMING REQUIRED TO INSTALL ALL HVAC EQUIPMENT AS DESCRIBED OR IMPLIED ON THE DRAWINGS. CURBS SHALL BE A MINIMUM OF 14" HIGH, OF THE SAME MANUFACTURER OF THE EQUIPMENT SUPPORTED. INSULATE UNDER THE COMPRESSOR SECTION TO PREVENT CONDENSATION. ALL CURBS MUST BE INSTALLED SO THAT TOP OF CURBS ARE "DEAD' LEVEL ALL PENETRATIONS OF EXISTING STRUCTURE SHALL BE DONE IN ACCORDANCE TO THE LANDLORD'S GUIDELINES AT THIS CONTRACTOR'S EXPENSE. C. METAL DUCTWORK - NO FIBERGLASS DUCT ALLOWED 1. NO DUCTWORK SHALL BE FABRICATED PRIOR TO APPROVAL BY THE TENANT'S CONSTRUCTION MANAGER. SIGNIFICANT DEVIATIONS FROM DESIGN MUST BE APPROVED BY TENANT'S CONSTRUCTION MANAGER PRIOR TO FABRICATION OR INSTALLATION. ALL DUCT MAINS ARE TO BE RECTANGULAR UNLESS NOTES OTHERWISE. ALL DUCT BRANCHES TO DIFFUSERS ARE TO BE ROUND RIGID DUCT. (FLEXIBLE DUCT CONNECTIONS TO THE DIFFUSER ARE NOT ALLOWED ON THE ,. SALES FLOOR) 2 EXCEPT AS OTHERWISE INDICATED, FABRICATE AND INSTALL RECTANGULAR DUCTS WITH GALVANIZED SHEET STEEL, IN ACCORDANCE WITH THE COUNTRY'S "HVAC DUCT CONSTRUCTION STANDARDS' LATEST EDITION. CONFORM TO THE REQUIREMENTS IN THE REFERENCED STANDARD FOR METAL THICKNESS, REINFORCING TYPES AND INTERVALS, TIE ROD APPLICATIONS, AND JOINT TYPES AND INTERVALS. 3. EXCEPT WHERE OTHERWISE INDICATED, CONSTRUCT DUCT SYSTEMS TO THE FOLLOWING PRESSURE CLASSIFICATIONS: (VERIFY WHETHER RETURN OR EXHAUST DUCT IS POSITIVE OR NEGATIVE PRESSURE). A. SUPPLY DUCTS: 2 INCHES WATER GAUGE, POSITIVE PRESSURE B. RETURN AND EXHAUST DUCTS: 2 INCHES WATER GAUGE, NEGATIVE PRESSURE. PRESSURE TEST DUCTS FOR LEAKAGE. REMAKE LEAKING JOINTS AND APPLY SEALANTS AS REQUIRED TO FABRICATE A SYSTEM THAT DOES NOT EXCEED 5% LEAKAGE OR LESS AS STATED BY PRESSURE CLASS RATINGS IN SMACNA STANDARDS, 4. AS A MINIMUM, CROSSBREAK ALL FLAT SURFACES OR REINFORCE WITH A BEAD APPROXIMATELY 3/8" WIDE X 3/16" DEEP ON 12' CENTERS TO PREVENT VIBRATIONS. 5. INSTALL DOUBLE THICKNESS TURNING VANES IN ALL RIGHT ANGLE ELBOWS. 6. INSTALL RIGID ROUND AND RECTANGULAR METAL DUCT WITH SUPPORT SYSTEMS INDICATED IN SMACNA STANDARDS. SUPPORT HORIZONTAL DUCTS WITHIN 2 FEET OF EACH ELBOW AND WITHIN 4 FEET OF EACH BRANCH INTERSECTION USING DOUBLE STRAP HANGERS ON EACH SIDE OF FITTING. SUPPORT VERTICAL DUCTS AT A MAXIMUM INTERVAL OF 16 FEET AND AT EACH FLOOR. NO WOOD SHALL BE USED TO SUPPORT OR BRACE DUCTS. PROVIDE SWAY AND SEISMIC BRACING AS REQUIRED BY STATE AND COUNTRY CODES OR BY LANDLORD. 7. WHERE DUCTS PASS THROUGH ROOFS AND FLOORS, PROVIDE AS MINIMUM 1- 1/2"X1-1/2" X1/8" STEEL ANGLE FRAMES AT EACH SIDE OF OPENING. THE ANNULAR SPACE BETWEEN DUCT AND ANGLE FRAMES SHALL BE CAULKED WITH SILICONE SEALANT OR FIREPROOFED AS REQUIRED BY ASSEMBLY FIRE RATING. 8 ALL TRAVERSE JOINTS AND SEAMS IN SUPPLY AIR DUCT SHALL BE SEALED AIR TIGHT WITH DAP CMC DUCT SEALER. JOINTS ALSO SHALL BE RIVETED OR CONNECTED WITH SHEET METAL SCREWS. SOFT ELASTOMER BUTYL GASKET WITH ADHESIVE BACKING SHALL BE USED TO SEAL FLANGED JOINTS. 10. DUCT TRANSITIONS SHALL NOT EXCEED 30 DEGREES SLOPE EXCEPT AS SPECIFICALLY NOTED OTHERWISE. 11. PROVIDE ACCESS TO ALL MOTORIZED DAMPERS, FIRE DAMPERS, CONTROLS, AND OTHER ITEMS IN DUCTWORK THAT REQUIRE SERVICE OR INSPECTION. IF THE ACCESS PANEL LOCATION IS EXPOSED TO THE SALES AREA, IT MUST BE APPROVED BY THE TENANT'S CONSTRUCTION MANAGER PRIOR TO INSTALLATION. LAY -IN SUPPLY AND RETURN AIR DIFFUSERS, GRILLES AND REGISTERS WITH PLASTER FRAMES MAY BE USED AS ACCESS LOCATIONS. 12. FLEXIBLE CONNECTIONS A. FLEXIBLE COLLARS SHALL BE PROVIDED IN ALL CONNECTIONS BETWEEN VIBRATING EQUIPMENT (FANS, ROOFTOP UNITS, AIR HANDLERS, FAN POWERED VAV BOXES, ETC.) AND DUCTS OR CASINGS. ALSO, PROVIDE FLEXIBLE CONNECTIONS WHERE DUCTS CROSS BUILDING EXPANSION JOINTS. B FLEXIBLE CONNECTIONS SHALL CONSTRUCTED OF NEOPRENE -COATED FLAMEPROOF FABRIC. PROVIDE ADEQUATE JOINT FLEXIBILITY TO ALLOW FOR MOVEMENT AND PREVENT THE TRANSMISSION OF VIBRATION. C. FLEXIBLE CONNECTION IS TO BE RATED FOR THE OPERATING PRESSURE OF THE SYSTEM. 13. FIRE DAMPERS A. PROVIDE PRIMARY FIRE DAMPERS WHERE INDICATED OR REQUIRED BY CODES. DAMPERS SHALL BE DESIGNED FOR HORIZONTAL OR VERTICAL FLOW OF AIR AS REQUIRED. FIRE DAMPERS SHALL BE UL LABELED. B. FIRE DAMPERS SHALL HAVE THE BLADES OUT OF THE AIRSTREAM AND A 165'E FUSIBLE LINK, TYPE A, AS MINIMUM. C. PROVIDE ALL NECESSARY FRAMING AND SLEEVES FOR DAMPER MOUNTING PER UL AND CODE REQUIREMENTS. D. PROVIDE DUCT ACCESS DOORS IN AN ACCESSIBLE LOCATION FOR ALL FIRE DAMPERS. DOOR IS TO BE 20 GA GALVANIZED DOOR WITH QUICK -OPENING LATCH AND PIANO HINGE. 14. COMBINATION FIRE/SMOKE DAMPERS: A. PROVIDE COMBINATION FIRE/SMOKE DAMPERS WHERE SHOWN ON DRAWINGS AND AS REQUIRED BY CODE ENFORCING AUTHORITY WITH FIRE/SMOKE RATINGS AS REQUIRED TO MAINTAIN THE FIRE RATING NOTED ON THE ARCHITECTURAL DRAWINGS. DAMPERS SHALL MEET UL 555 CLASSIFICATION FOR FIRE RATING AND UL 555S CLASSIFICATION OF LEAKAGE CLASS II SMOKE DAMPER; DAMPER SHALL BEAR A UL LABEL ATTESTING TO THESE CLASSIFICATIONS. PROVIDE FIRE DAMPER WITH A 165' F RESETTABLE TEMPERATURE DEVICE. RATE FIRE/SMOKE DAMPERS FOR A MINIMUM VELOCITY OF 2,000 FPM AND PRESSURE OF 4" W.G. PROVIDE MANUFACTURER RECOMMENDED STEEL SLEEVE OF LENGTH AS REQUIRED TO MEET THE INSTALLED LOCATION. PROVIDE A QUALIFIED 120 VOLT ELECTRIC ACTUATOR INSTALLED BY THE MANUFACTURER AT TIME OF DAMPER FABRICATION. ACTUATORS SHALL BE RATED FOR A MINIMUM OF 20,000 CYCLES OF OPERATION, SHALL COMPLY WITH THE LOCALLY ADOPTED BUILDING CODE AND SHALL OPEN IN 15 SECONDS OR LESS AND CLOSE IN 15 SECONDS OR LESS AFTER ALARM OR SMOKE DETECTION HAS OCCURRED. PROVIDE STAINLESS STEEL SPRING LOADED LEAKAGE SEALS IN SIDES OF CASING, AND TERMINAL BLOCK FOR CONNECTION TO THE BUILDING FIRE ALARM SYSTEM. B. DAMPER SHALL BE MANUFACTURED BY RUSKIN, AIR BALANCE, GREENHECK, CESCO, UNITED AIR OR NAILOR INDUSTRIES. PROVIDE ACCESS DOOR, SIZED PER SMACNA WITH MINIMUM SIZE OF 10" BY 10", IN DUCT FOR INSPECTION AND SERVICE TO FIRE DAMPER AND FUSIBLE LINK. PROVIDE DUCT ACCESS DOOR(S) WITHIN 12 INCHES OF THE DEVICE TO ALLOW FOR TESTING AND MAINTENANCE. ' LABEL EACH DOOR (WITH MINIMUM 1" LETTERING) INDICATING WHICH DAMPER TYPE IS SERVED. DOOR SHOULD BE CAPABLE OF BEING FULLY OPENED OR PROVIDE REMOVABLE DOOR. PROVIDE REMOVABLE SECTION OF DUCT WHERE DUCT SIZE IS T00 SMALL FOR 10" BY 10" ACCESS DOOR. PROVIDE ACCESS DOOR IN CEILING OR WALL AS REQUIRED TO ACCESS DAMPER. 15. FLEXIBLE AIR DUCT A. FLEXIBLE AIR DUCT SHALL BE 1" INSULATED CLASS 1 AND RATED FOR THE OPERATING PRESSURE OF THE SYSTEM. DUCT CONSTRUCTION MATERIAL (PLASTIC, CLOTH, ALUMINUM) MUST ADHERE TO LOCAL CODES AND LANDLORD'S REQUIREMENTS AND BE INCLUDED AS SUCH IN THE BID. FLEXIBLE AIR DUCT MAY ONLY BE USED IN VERTICAL APPLICATIONS WITH PRIOR APPROVAL FROM TENANT'S CONSTRUCTION MANAGER, C. FLEXIBLE DUCT SHALL NOT EXTEND OVER 5'-0" IN LENGTH AT ANY ONE LOCATION, 16. SUPPLY AIR TAKE -OFF FITTINGS A. PROVIDE CONICAL OR "BELL -MOUTH" TAKE -OFFS FROM MAIN DUCTWORK TO ROUND BRANCHES. INSTALL PER MANUFACTURER'S INSTRUCTIONS. B. PROVIDE 45" RECTANGULAR TAKE -OFFS FROM MAIN DUCTWORK TO RECTANGULAR BRANCHES. 17. DAMPERS A. PROVIDE MANUAL LOCKING QUADRANT VOLUME CONTROL DAMPERS WITH HANDLE OPERATORS IN EACH BRANCH DUCT AND AS SHOWN ON PLANS TO FACILITATE AIR BALANCING. B. WHERE ACCESS TO BALANCING DAMPER IS RESTRICTED, YOUNG'S REGULATORS SHALL BE USED. C. ALL RECTANGULAR DAMPERS IN OUTSIDE AIR, RELIEF AIR, OR RETURN AIR DUCTS ARE TO BE OF OPPOSED BLADE TYPE. ALL OUTSIDE AIR DUCT DAMPERS MUST ALSO BE OF THE LOW LEAKAGE TYPE. D. ALL MOTORIZED DAMPERS NOT FURNISHED WITH EQUIPMENT ARE TO BE HONEYWELL DAMPERS. 18. DIFFUSERS, GRILLES, AND REGISTERS A. PROVIDE DIFFUSERS GRILLES AND REGISTERS AS SCHEDULED. DEVICES TO BE COMPLETE WITH DAMPERS FRAMES AND ALL ACCESSORIES. FINISH AS INDICATED. B INSTALL ALL AIR DEVICES AS LOCATED ON THE ARCHITECTURAL REFLECTED CEILING PLAN. C. APPROVED MANUFACTURERS: TITUS IS SPECIFIED, EQUALS BY METALAIRE OR KRUEGER IS ACCEPTABLE. 19. MEDIUM PRESSURE DUCT 20. DUCTWORK INSULATION A. INSTALL INSULATION PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS, AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. INSULATION MUST COMPLY WITH NFPA 90A. DUCT SIZES SHOWN ON DRAWINGS ARE INSIDE CLEAR DIMENSIONS. INSULATE SUPPLY AND RETURN AIR RECTANGULAR DUCTWORK WHERE SHOWN ON PLAN. DUCTWORK SHALL BE EXTERNALLY WRAPPED WITH 1-1/2" THICK, FOIL FACED FIBERGLASS INSULATION. ALL ROUND AND OUTSIDE AIR DUCTWORK ABOVE THE CEILING SHALL BE EXTERNALLY INSULATED WITH A MINIMUM OF 1' THICK, 1-1/2 LB. DENSITY (R=6) DUCT WRAP WITH VAPOR BARRIER. VAPOR BARRIER IS TO BE MAINTAINED THROUGHOUT DUCT SYSTEM. ALL JOINTS MUST BE TAPED SO THAT NO INSULATION FIBER IS VISIBLE. EXTEND DUCTWORK INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS, AND SIMILAR PENETRATIONS. D. DUCTWORK LOCATED IN THE CONDITIONED SPACE SHALL NOT BE INSULATED UNLESS OTHERWISE NOTED ON PLANS. INSULATE ALL DUCT DROPS OR THE FIRST 20 FEET OF DUCT AT THE HVAC UNITS IN ALL CASES. E. ALL INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NO HIGHER THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM C 411, OR AS REQUIRED BY LOCAL CODES. 21. SYSTEM CLEANOUT A. DUCTWORK AND AIR HANDLING EQUIPMENT IS TO BE CLEANED OUT AND BLOWN OUT BEFORE PAINTING IS STARTED BY THE GENERAL CONTRACTOR. B. FILTERS MUST BE IN UNITS AT ANY TIME FANS ARE OPERATED. D. HYDRONIC PIPING 1. FURNISH AND INSTALL A COMPLETE HYDRONIC PIPING SYSTEM IF APPLICABLE. REFER TO PLANS TO DETERMINE IF A HYDRONIC SYSTEM IS REQUIRED. 2. PIPING A. HYDRONIC PIPING FOR CHILLED WATER, CONDENSER WATER AND/OR HEATING WATER SHALL BE ASTM A-53, SCHEDULE 40, ERW, BLACK STEEL PIPE WITH PLAIN ENDS. INSTALL STEEL PIPE WITH WELDED JOINTS WHERE PIPE IS 2-1/2 INCH AND LARGER. INSTALL STEEL PIPE WITH THREADED JOINTS AND FITTINGS. INSTALL TYPE "K" COPPER PIPE FOR 2 INCH AND SMALLER PIPE. PROVIDE DIELECTRIC UNIONS BETWEEN DISSIMILAR METALS. ALL PIPING SHALL BE IN STRICT CONFORMANCE WITH ASTM, ASA, AND LANDLORD'S REQUIREMENTS. WHICHEVER IS MOST STRINGENT. UNIONS OR FLANGES MUST BE USED AT EQUIPMENT CONNECTIONS WHERE SERVICE OR REMOVAL. MAY BE REQUIRED. B. ALL PIPING AND EQUIPMENT SHALL BE PRESSURE TESTED WITHOUT LEAKAGE AT A MINIMUM PRESSURE OF 125 PSI. C. ALL HYDRONIC PIPING AND EQUIPMENT CONNECTED TO THE HVAC PIPING SYSTEM SHALL BE CLEANED AND FLUSHED. REMOVE, CLEAN, AND REPLACE STRAINER SCREENS. FILL TENANT'S SYSTEM WITH DOMESTIC WATER AND VENT ALL PIPING AND EQUIPMENT PRIOR TO CONNECTION TO THE LANDLORD'S SYSTEM. CONTRACTOR SHALL NOT FILL TENANT'S SYSTEM WITH WATER FROM THE LANDLORD'S SYSTEM UNLESS SPECIFICALLY INSTRUCTED TO DO SO FROM THE LANDLORD'S FIELD REPRESENTATIVE. ANY RUNS THRU A CHASE OR SHAFT WILL BE DONE WITH FEWEST JOINTS POSSIBLE USING THE LONGEST LENGTH OF HARD COPPER PIPE AVAILABLE. SHOULD A JOINT BE REQUIRED, CONTRACTOR SHALL MAKE ALL EFFORTS TO KEEP THE JOINTS IN ACCESSIBLE AREAS. D. PRIOR TO CONNECTION TO THE LANDLORD'S SYSTEM, CONTRACTOR SHALL OBTAIN WRITTEN CONFIRMATION FROM THE LANDLORD'S FIELD REPRESENTATIVE, THAT ALL TESTING, FLUSHING, AND PROPER FILLING OF THE TENANT'S SYSTEM HAS BEEN COMPLETED IN ACCORDANCE TO THE LANDLORD'S REQUIREMENTS AND THAT THE TENANTS SYSTEM IS READY TO BE CONNECTED TO THE LANDLORD'S SYSTEM. 3. PIPING SPECIALTIES A. PRESSURE/TEMPERATURE TEST PLUGS (PETE'S PLUG) - 1/4 INCH NPT FITTINGS TO RECEIVE EITHER A TEMPERATURE OR PRESSURE PROBE, 1/8 INCH 0.D. FITTING AND CAPS SHALL BE BRASS WITH VALVE CORE OF NORDEL, RATED AT 400 PSIG, 0 TO 200 DEGREES F. B. STRAINERS - "Y" PATTERN STRAINERS, 125 PSIG, CAST IRON BODY WITH PERFORATED STAINLESS STEEL SCREEN, THREADED FOR 2 INCHES AND SMALLER, FLANGED FOR 2-1/2 INCHES AND LARGER. SCREEN OPENING SIZE AT 0.033 INCH FOR HEATING AND 1/8 INCH FOR CHILLED OR CONDENSER WATER. PROVIDE WITH BLOWDOWN VALVE WITH HOSE END FITTING. 4. GENERAL INSTALLATION A. INSTALL WATER MAINS WITHOUT PITCH. USE ECCENTRIC REDUCING COUPLINGS AT CHANGES IN SIZE WITH THE TOP OF PIPES AT SAME ELEVATION. B. BRANCHES TO UNITS BELOW MAINS TO BE TAKEN FROM BOTTOM OF MAINS AT A 45 DEGREE ANGLE, PITCH DOWNWARD TOWARD UNITS. BRANCHES TO UNITS ABOVE MAINS TO BE TAKEN FROM TOP OF MAINS AT A 45 DEGREE ANGLE PITCHED UPWARD TOWARDS UNITS. PITCH NOT LESS THAN 1" TO 10 FEET. SEE MECHANICAL DETAIL DRAWINGS FOR APPLICABLE DETAILS. PROVIDE UL LISTED FIRE STOPPING SYSTEM AROUND ALL PIPING PENETRATIONS THROUGH RATED WALLS. PENETRATIONS SHALL MEET THE REQUIREMENTS OF UL DETAILS WL1001 (UNINSULATED WALL) AND WL5039 (INSULATED WALL). E. REFRIGERANT PIPING THIS CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE REFRIGERANT PIPING SYSTEM BETWEEN THE INDOOR FAN UNITS AND OUTDOOR CONDENSING UNITS. REFER TO PLANS TO DETERMINE IF A REFRIGERANT SYSTEM IS REQUIRED. NEW PIPING IS REQUIRED. REUSE OF EXISTING PIPING IS NOT ALLOWED. PIPING A. REFRIGERANT PIPING SHALL BE TYPE ACR COPPER TUBING. TUBING SHALL BE CLEAN AND CLEAR OF DEBRIS, AND EVACUATED WTFH A DEEP VACUUM PRIOR TO REFRIGERANT CHARGE. THE CONTRACTOR SHALL CONFIRM THE DIAMETER OF THE REFRIGERANT PIPING RUNS IN EXCESS OF 50 EQUIVALENT FEET WITH THE ARCHITECT, ENGINEER, AND MANUFACTURER FOR ALL SPLIT SYSTEMS, NO REFRIGERANT PIPING RUNS EXCEEDING 100 EQUIVALENT FEET ARE TO BE INSTALLED WITHOUT LIMITED BRANDS' PERMISSION. THE MANUFACTURER SHALL PROVIDE ALL FINAL PIPE SIZING AND COIL SELECTIONS FOR ALL REFRIGERANT PIPING SYSTEMS. ALL FITTINGS AND JOINTS SHALL BE WROUGHT COPPER OR CAST BRONZE (ANSI 816.22).. ALL COPPER TO COPPER JOINTS SHALL BE BRAZED WITH A COPPER -PHOSPHORUS ALLOY AND ALL OTHER JOINTS SHALL BE BRAZED WITH SILFOS-5 ALLOY. C. ALL ELBOWS ARE TO BE LONG RADIUS TYPE. 3. INSTALLATION A. REFRIGERANT PIPE SIZING SHALL BE THE RESPONSIBILITY OF THE HVAC SUPPLIER. CONTRACTOR WILL PROVIDE A SCHEMATIC PROPOSED LAYOUT OF THE SYSTEM INCLUDING ALL ELBOWS, RISES, RUNS, ETC., WITH DIMENSIONS. THE HVAC SUPPLIER WILL THEN PROVIDE WRITTEN DOCUMENTATION OF PIPE SIZES AND ADDITIONAL REQUIRED SYSTEM COMPONENTS TO THE FIELD. B. SUCTION LINES SHALL HAVE ADEQUATE LIFT TRAPS AND/OR DOUBLE SUCTION RISERS TO MEET THE REQUIREMENTS OF FIELD CONDITIONS AND. EQUIPMENT MANUFACTURER'S RECOMMENDATIONS, BRAZE ALL JOINTS WITH SILFOS-5 STARTING AT THE INDOOR UNIT AND WORKING TOWARD THE OUTDOOR UNIT. THE SEALS ON THE OUTDOOR UNIT SHALL BE BROKEN LAST. A NITROGEN BLEED SHALL BE USED DURING ALL. BRAZING AND ANY TIME THE SYSTEM IS OPEN. ALL OPEN LINES SHALL BE CAPPED AND SEALED BEFORE LEAVINGDURI NG THE CONSTRUCTION. PRESSURE TESTFORAN 0 ESSU E LEAKS WITH INERT.. GAS UP TO 245 PSIG. REDO LEAKING JOINTS AND RETEST UNTIL SYSTEM IS TIGHT. EVACUATE ENTIRE SYSTEM TO 200 MICRONS OF MERCURY. CHARGE SYSTEM WITH 25 PSI OF R-22 AND A INERT GAS TO 245 PSI AND RETEST SYSTEM. ENERGIZE CRANK CASE HEATERS 24 HOURS PRIOR TO STARTING COMPRESSOR TO ENSURE THAT ALL REFRIGERANT UQUID IS OUT OF THE COMPRESSOR. D. UPON COMPLETION OF TESTING, BUT BEFORE THE REFRIGERANT PIPING INSULATION IS APPLIED, THE PIPING MUST BE INSPECTED BY A REPRESENTATIVE OF THE LOCAL GOVERNING AUTHORITY AS NECESSARY. INSULATE THE REFRIGERANT SUCTION LINES AND CONDENSATE LINES WITH RUBATEX OR ARMSTRONG 1 INCH THICK PIPE INSULATION WITH FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NOT MORE THAN 50 IN ACCORDANCE WITH INDUSTRY STANDARDS. DO NOT INSULATE THE HOT GAS (LIQUID) LINES OR ANY HOT GAS BYPASS. PROVIDE UL LISTED FIRE STOPPING SYSTEM AROUND ALL PIPING PENETRATIONS THROUGH RATED WALLS. PENETRATIONS SHALL MEET THE REQUIREMENTS OF UL DETAILS WL1001 (UNINSULATED WALL) AND WL5039 (INSULATED WALL). 4. INSPECTION A. CONTRACTOR MUST PREPARE AND SUBMIT A COMPLETE PIPING SCHEMATIC TO THE LOCAL MANUFACTURER REPRESENTATIVE FOR APPROVAL PRIOR TO BEGINNING INSTALLATION. UPON COMPLETION OF PIPING, THIS CONTRACTOR MUST CALL THE LOCAL REPRESENTATIVE FOR FIELD INSPECTION OF WORK PERFORMED . ALL ITEMS FOUND TO BE INADEQUATE FOR PROPER PERFORMANCE BY MANUFACTURER REPRESENTATIVE MUST BE CORRECTED. THIS INSPECTION IS PERFORMED AT LSD&C EXPENSE. F. SYSTEM TESTING, ADJUSTING, AND BALANCING 1. TESTING, ADJUSTING AND BALANCING OF ALL WORK SHALL BE MADE BY AN INDEPENDENT CONTRACTOR WHO IS CURRENTLY LICENSED ASSOCIATED AIR BALANCING COUNCIL (AABC) OR NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB) BALANCING CONTRACTOR. NO OTHER BALANCE REPORTS WILL BE REVIEWED OR ACCEPTED. ALL BALANCING WORK MUST BE COMPLETE AND DONE IN ACCORDANCE WITH THE MOST RECENT STANDARDS OF THEIR SOCIETY. PAYMENT OF ALL COSTS FOR TESTING SHALL BE MADE BY THE HVAC CONTRACTOR. 2. THE HVAC CONTRACTOR SHALL INSTALL NEW FILTERS IN ALL UNITS PRIOR TO THE AIR BALANCE. THE COMPLETE AIR BALANCE SHALL TAKE PLACE WITH OUTSIDE AIR DAMPERS IN MINIMUM POSITION. 3 BALANCE AIR AND WATER QUANTITIES TO WITHIN + 5% OF THAT INDICATED ON THE DRAWINGS. ANY REQUIRED CHANGES IN SHEAVES, BELTS, PULLEYS, OR THE ADDITION OF DAMPERS REQUIRED TO ACHIEVE SPECIFIED FLOW RATES SHALL BE PERFORMED BY THE HVAC CONTRACTOR WITH NO ADDITIONAL COST TO THE TENANT. 4. THE BALANCE REPORT SHALL INCLUDE AS A MINIMUM THE FOLLOWING INFORMATION: A. AABC OR NEBB CERTIFICATION NUMBER AND SIGNATURE OF BALANCING CONTRACTOR. B. INSTRUMENTATION UST WITH LAST CALIBRATION DATES. C. MAKE AND MODEL NUMBERS OF ALL HVAC EQUIPMENT TESTED. D. AIR CFM AND STATIC PRESSURE READINGS (DISCHARGE AND SUCTION) AS MEASURED BY PITOT TUBE DUCT TRAVERSE AT THE UNIT. E. MOTOR NAMEPLATE DATA WITH ACTUAL FIELD VOLTAGE AND AMPERAGE READINGS FOR EACH LEG. F. MOTOR AND FAN RPMS, SHEAVE SIZES AND BELT SIZES. G. OUTSIDE, RETURN, MIXED AND SUPPLY AIR TEMPERATURES AT FULL COOLING. H. WATER BALANCE DATA INCLUDING GPM WITH INLET AND OUTLET TEMPERATURE AND PRESSURE READINGS (WHERE APPLICABLE). I. MAKE AND MODEL NUMBERS OF ALL AIR DISTRIBUTION EQUIPMENT. J. FINAL BALANCED AIR VOLUMES AT ALL OUTLETS (INCLUDING RETURNS WHERE DUCTED). K. INDEXED PLAN WITH DIFFUSER AND RETURN LOCATIONS. L REPORT SHALL INCLUDE VAV BOX AIRFLOW SENSOR DIFFERENTIAL PRESSURE READING AT MAX. AND MIN. COOLING. 5. ALL CONTROL SEQUENCES SHALL BE TESTED (INTERLOCKED EQUIPMENT, SMOKE DETECTORS, SMOKE EVACUATION, ECONOMIZER, ETC.) AND OPERATING STATUS RECORDED IN THE REPORT. 6. THREE COPIES OF THE BALANCE REPORT SHALL BE SUBMITTED THROUGH THE GENERAL CONTRACTOR TO THE TENANT'S CONSTRUCTION MANAGER` FOR APPROVAL 7 THE BALANCING CONTRACTOR SHALL PERFORM ALL APPLICABLE TESTING AND BALANCING FUNCTIONS REQUIRED FOR THE SYSTEM DESIGNED IN THESE DRAWINGS. THE BALANCING CONTRACTOR SHALL RECHECK ANY ITEMS THAT THE TENANT DEEMS NECESSARY AT NO ADDITIONAL COST TO THE TENANT. 8. FINAL BALANCE REPORT SHALL BE INCLUDED IN THE OPERATION & MAINTENANCE MANUALS. G. FINAL HVAC INSPECTIONS 1. ASIDE FROM NORMAL INTERIM INSPECTIONS OF WORK IN PLACE, THE TENANT SHALL HAVE THE RIGHT TO AN INDEPENDENT HVAC CONTRACTOR INSPECT THE FINISHED HVAC INSTALLATION UPON COMPLETION FOR COMPLIANCE WITH THE PLANS, SPECIFICATIONS, AND CODES. THE INSTALLING CONTRACTOR WILL BE RESPONSIBLE TO BRING ALL ITEMS REPORTED BY THE INDEPENDENT HVAC CONTRACTOR UP TO PLANS AND SPECIFICATION REQUIREMENTS AT NO COST TO TENANT. DIVISION 15 - MECHANICAL SECTION 15300 FIRE PROTECTION A. SCOPE OF WORK 1. THE F.P. CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE SPRINKLER SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDmONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: (REFER TO RESPONSIBILITY SCHEDULE FOR EXACT RESPONSIBILITIES) A. INSTALLATION OF NEW WET SPRINKLER SYSTEM AS REQUIRED TO PROVIDE COVERAGE IN ACCORDANCE WITH NFPA-13, LOCAL CODES, LANDLORD'S CRITERIA, AND INSURANCE CARRIERS FOR THE MALL AND TENANT. B. TAPS, RISERS, LATERALS, BRANCHES, VALVES, ALARMS, SPRINKLER HEADS AND ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM. C. DESIGN DRAWINGS, CALCULATIONS, SUBMITTALS AND APPROVALS. D. PERMITS, FEES, AND CHARGES. E. TESTS AND TEST CERTIFICATES. F. COST FOR SHUT DOWN FEES. 2 THE CONTRACTOR THAT DOES THE ACTUAL SPRINKLER WORK IS REQUIRED TO BE A LANDLORD APPROVED SPRINKLER CONTRACTOR. 3. BEFORE STARTING WORK, THE CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE FIRE PROTECTION SYSTEM, MATERIALS, AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. 4 RELOCATION OF EXISTING MAINS, LATERALS, BRANCHES AND RISERS TO FACILITATE STORE DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL. B. SHOP DRAWINGS 1. THE FIRE PROTECTION CONTRACTOR SHALL PREPARE DETAILED SHOP DRAWINGS AND CALCULATIONS FOR HIS WORK. SUBMIT SIX (6) COPIES TO GENERAL CONTRACTOR FOR APPROVAL. NO WORK SHALL BEGIN UNTIL TENANT'S CONSTRUCTION MANAGER APPROVES HEAD AND PIPING LOCATIONS. THE FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SUBMITTING COORDINATED DRAWINGS, CALCULATIONS, HEAD TYPES AND COLORS TO ALL AUTHORITIES HAVING JURISDICTION FOR APPROVAL. NO WORK SHALL BEGIN UNTIL ALL APPROVALS HAVE BEEN RECEIVED. A COPY OF THE LETTER OF APPROVAL FROM THE LANDLORD'S INSURANCE RATING BUREAU SHALL BE FORWARDED TO THE LANDLORD'S AGENT AND TO THE TENANT'S CONSTRUCTION MANAGER. C. EQUIPMENT 1. SPRINKLER HEADS: A. ALL SPRINKLER HEADS SHALL BE NEW (EXISTING HEADS SHALL BE REPLACED AS NECESSARY), U.L, F.M. LISTED AND APPROVED AUTOMATIC SPRAY TYPE AS MANUFACTURED BY CENTRAL SPRINKLER CO., GLOBE, GRINNELL, RELIABLE, STAR, OR VIKING. B ALL SPRINKLER HEADS SHALL BE RATED FOR 165'F UNLESS INDICATED OTHERWISE ON DRAWINGS OR REQUIRED BY LOCAL CODES. C. ALL SALES FLOORS HEADS ARE TO HAVE BE FACTORY APPLIED COLOR FINISH TO MATCH ARCHITECTURAL C ECTURAL CEILING FINISH. VERIFY HEAD TYPES AND COLORS WITH TENANT'SCONSTRUCTION CONS UCTION MANAGER ANDMIT WITH SUB SPRINKLER DRAWINGS FOR PERMIT. D SPRINKLER HEAD TYPES SHALL BE AS FOLLOWS: 1. FINISHED CEILING (SALES AREA) - FULLY RECESSED/CONCEALED TYPE 2. FINISHED CEILING NON -SALES AREA) - SEMI -RECESSED TYPE 3. NO -CEILING - CHROME UPRIGHT TYPE. NOTE:SEMI-RECESSED HEADS SHALL PROTRUDE NO MORE THAN 1" BELOW LEVEL OF CEILING OF SOFFIT. ALL HORIZONTAL SPRINKLER RUNS AT SIDEWALL SOFFITS SHALL BE CONCEALED WITHIN SOFFIT FRAMING. D. GENERAL PIPING 1 A FIRE PROTECTION SYSTEM STUB IN SHALL BE FURNISHED BY THE LANDLORD. SPRINKLER SPACING SHALL NOT EXCEED 130 SQ. FT. IN "SALES" AREAS AND 100 SQ. FT. IN 'STOCK" AREAS. COMPLY WITH LANDLORD'S DESIGN CRITERIA. PIPE SIZING SHALL BE BASED ON NFPA ORDINARY HAZARD. 2. ALL SPRINKLER LINES SHALL BE INSTALLED CONCEALED, AVOIDING INTERFERENCE WITH LIGHTS, DUCTS, PIPES, STORAGE DECK, ETC. FIRE PROTECTION CONTRACTOR SHALL PREPARE COORDINATED SHOP DRAWINGS INDICATING THE LOCATIONS OF ALL SPRINKLER HEADS, SPRINKLER LINES, LIGHTS, DIFFUSERS, GRILLES AND REGISTERS PRIOR TO INSTALLATION. HORIZONTAL SPRINKLER RUNS AT MERCHANDISE SOFFITS SHALL BE PLACED INSIDE SOFFIT STRUCTURE. VERTICAL DROPS FROM CEILING TO MERCHANDISE SOFFIT SHALL BE LOCATED FLUSH AGAINST DEMISING WALLS. 3 WHERE POSSIBLE, REWORK THE EXISTING SPRINKLER SYSTEM TO MEET THE NEW REQUIREMENTS OF THIS DESIGN. RELOCATE ALL MAINS AND BRANCHES INTERFERING WITH CEILING HEIGHTS, EQUIPMENT, AND MAJOR COMPONENTS INCLUSIVE OF ADJACENT TENANTS AND MALL COMMON AREAS, REMOVE ALL UNUSED PIPING. 4 LOCATIONS OF ALL HEADS SHOULD BE APPROVED BY THE LOCAL FIRE PROTECTION OFFICIAL AND THE TENANT'S CONSTRUCTION MANAGER BEFORE INSTALLATION. HEADS MUST BE LOCATED IN THE CENTER OF CEILING TILES AND IN A SYMMETRICAL PATTERN WITH OTHER CEILING FIXTURES. ADDITIONAL MONIES WILL NOT BE ALLOCATED FOR ADDEONAL HEADS REQUIRED BY FIELD FIRE INSPECTOR AFTER BIDS ARE ACCEPTED. HEADS IN MERCHANDISE BAYS SHALL BE CENTERED SIDE TO SIDE AND FRONT TO BACK. PROVIDE AND INSTALL A VALVED TEST CONNECTION FOR THE SPRINKLER SYSTEM AS REQUIRED OR REQUESTED BY THE MALL LOCAL INSPECTOR, OR INSURANCE CARRIER. COORDINATE LOCATION WITH TENANT'S CONSTRUCTION MANAGER AND LOCAL FIRE PROTECTION OFFICIAL PRIOR TO ROUGH -IN. 6. SPRINKLER HEADS LOCATED IN STOCK, CORRIDOR ON TOILET ROOM CEILINGS OR WALLS BELOW 8'-0" ABOVE THE FINISHED FLOOR ARE TO BE PROTECTED WITH APPROVED GUARDS. E. PIPING: 1. SCHEDULE 40, BLACK STEEL PIPE, ASTM A-53 FOR FERROUS PIPING, WELDED AND SEAMLESS, ANSI B-36-10-70 FOR WROUGHT STEEL PIPE. 2. CAST IRON OR MALLEABLE IRON SCREWED FITTINGS FOR PIPES 2 INCHES AND SMALLER. SCREWED OR CAST IRON FLANGED JOINTS FOR PIPES LARGER THAN 2 INCHES. 3 GALVANIZED OR BLACK MALLEABLE IRON WITH BRASS SEAT SCREWED UNIONS FOR PIPES 2 INCHES AND SMALLER. 4 VICTAULIC TYPE COUPLINGS ARE ACCEPTABLE, WHERE APPROVED BY CODE AND THE LANDLORD. F. TESTS 1. WHEN COMPLETED, THE ENTIRE FIRE PROTECTION PIPING SYSTEM SHALL BE HYDROSTATICALLY TESTED AS REQUIRED BY THE RULES AND REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION. SYSTEM SHALL SHOW NO SIGNS OF LEAKAGE OR OTHER DEFECTS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO THE WORK OF THE OTHER CONTRACTORS OR TO THE BUILDING, OR TO ITS CONTENTS, PEOPLE, ETC., CAUSED BY LEAKS IN ANY OF THE EQUIPMENT INSTALLED BY HIM. ALL REPAIRS OR REPLACEMENT OF DAMAGES SHALL BE AT THIS CONTRACTOR'S EXPENSE. 2. PROPERLY COMPLETED AND SIGNED "SPRINKLER CONTRACTOR'S MATERIAL AND TEST CERTIFICATES" SHALL BE FURNISHED TO THE LANDLORD, AUTHORITIES HAVING JURISDICTION, AND TENANT'S CONSTRUCTION MANAGER. REVIEWED R CODE COMPLIANCE APPROVED MAY 2 1 2014 City of Tukwila BUILDING DIVISION M1OIo3 RECEIVED CITY OF TUKWILA MAY 1;4 2014 PERMIT CENTER MEP Engineer of Record Randall A. Nelson, P. E. 14817 West 95th Street Lenexa, Kansas 66215 Phone 913 322 5150 rci r 1 p r C z 0 P 0 0 w tt DATE -i z ,o, ��' OP . �r, 160 kgo r;! A. N WA, ,l 'k�tp. n =� Jii 448 : " X7,s� EXPIRES 9/21/2015 MECHANICAL SPECIFICATIONS LULLLEMO\ AT-LETCA CO\STUCTO\ STANDA=RDS 21 SOUTHCENTER, SUITE 748 TUKWILA, WA 98188 ISSUE FOR SD 03/24/14 ISSUE FOR DD-LLL 04/15/14 ISSUE FOR DD-LLD 04/18/14. ISSUE FOR CD-LLL 05/01/14 ISSUE FOR CD -LLD 05/01/14 ISSUE FOR PERMIT xx/xx/xx ISSUE FOR BID xx/xx/xx Scale: AS INDICATED Date: 3/7/14 Drawn By: DP/DB Checked By. CF Job Number: 142.0115 Drawing: