HomeMy WebLinkAboutPermit M14-0109 - CENTRAL WELDING SUPPLY - RTU AND DUCTWORKCENTRAL WELDING SUPPLY 15700 NELSON PL M14-0109 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No: 0005800029 Permit Number: M14-0109 Address: 15700 NELSON PL 1 Issue Date: 5/29/2014 Permit Expires On: 11/25/2014 Project Name: CENTRAL WELDING SUPPLY Owner: Name: WILTON LP Address: 18515 134TH ST NE , MONROE, WA, 98272 Contact Person: Name: AMANDA CRAMER Phone: (253) 872-5665 Address: 5108 D ST NW , AUBURN, WA, 98001 Contractor: Name: EMERALD AIRE INC. Phone: (253) 872-5665 Address: 5108 D ST NW , AUBURN, WA, 98001 License No: EMERAAI055BL Expiration Date: 4/1/2015 Lender: Name: Address: DESCRIPTION OF WORK: INSTALL (1) PACKAGED RTU AND CORRESPONDING OFFICE DUCTWORK. Valuation of Work: $0.00 Type of Work: NEW Fuel type: GAS Fees Collected: $389.62 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: • 2012 2012 2012 2012 Permit Center Authorized Signature: '272- `„C_ Z/11-- Date: GS ////5 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: &i/( // Date: Print Name: �� 10..(PfA K This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Mechanical Permit No. Al f '7 " 0 f O C% Project No. Date Application Accepted: Date Application Expires: Qr%a-o V /a:o /, (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 15 lCD Tenant Name: mac& U3v SAt PROPERTY OWNER Name: `,)\\ k."? 1\. Address: t.cE6\G \---5qin 5� �� City: (1�( State:f , ZipcRala, CONTACT PERSON — person receiving all project communication (�� Name: v `k c,al\k.Q� LepousacA Ps ‘1(‘6 Address: 5`K:S6 Sv, NNW City: t().1 `� 1 `r\ State: �J, , yA Zip:O)' Phone c0.3 3.95 Fax: a�J`� 54a?_ 5 Email: Cl'Kym e-Q.eivia t. K- • too King Co Assessor's Tax No.: ( 0 0a- Suite Number: Floor: New Tenant: ❑ Yes MECHANICAL CONTRACTOR INFORMATION Company Name: ernQ,� n ,( N `rq' \vt �.WC{' j tnv3 Address: v� 1 City: C�J�JWY\ State:``.1inl Zip: �'dW1 10 Phone: aS�J. a. Wax:gW tt a"5 —4 Contr Reg No.:0)y m c xp Date: q /` / 015 1 ll/v Tukwila Business License No.: —1 `1 Valuation of project (contractor's bid price): $ / 5/ WO- CD Describe the scope of work in detail: Iv\ Q (j 9U OY Q Cbcc i30 \ovi o u_ da d Use: Residential: New ❑ Replacement ❑ Commercial: New cgi Replacement ❑ Fuel Type: Electric j Gas Other: H:\Applications\Forms-Applications On Line\201 I ApplicationsWechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <l 00k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER AUTHORIZED AGENT: Signature: Date;; 5/19IFo!_4 Print Name: Day Telephone: gn'J---6-(-'5(siC Mailing Address: k.C!C)� City State Zip HAApplications\Forms-Applications On Line \201 I Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $389.62 M14-0109 Address: 15700 NELSON PL 1 Apn: 0005800029 $389.62 MECHANICAL $374.63 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $267.20 PLAN CHECK FEE R000.322.102.00.00 $74.93 TECHNOLOGY FEE $14.99 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2161 R000.322.900.04.00 $14.99 $389.62 Date Paid: Tuesday, May 20, 2014 Paid By: EMERALD AIRE INC Pay Method: CHECK 2132 Printed: Tuesday, May 20, 2014 10:59 AM 1 of 1 CRSYSTEMS INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 INSPECTION RECORD Retain a copy with permit Project: Type of Inspection: Address: 57°v }I✓(e) Pt: Date Called: Special Instructions: Date Wanted: u-' I2equestef:" Phone No: Approved per applicable codes. E Corrections required prior to approval. COMMENTS: Inspector: j RI INSPECTION FEE ' WIRED. Prior to next inspection. fee must be did at 6300 Southcente Blvd.. Suite 100. Call to schedule reinspection. Date,: INSPECTION RECORD j t Retain a copy with permit 114-d' PERMIT N0. -a-41) CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., *100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Prgject: . p Type of Inspection: _ Address: Date Called: Special Instructions: Date Wanted: , a 4 1 (.1. 411.1 Requester: Phone No: EaApproved per applicable codes. Corrections required prior to approval. COMMENTS: 4 t C t d c,? tAIE C, i`C;' A 11' ; (, A r .,rek ---2 E F A' ctor• INSPECTION FEB paid at 6300 Southce (-I REQUIRED. Plior to next inspection. fee must be ter Blvd.. Suite 100. Call to schedule reinspection. Date: _ 2 Co `i-- i y - 5" Tt i-Y f=44 L . L ftECEIV G N ILA CITY OF TUK 4. I QS 4 yUN 2 `� 2 r 2'x s84 T?aa6 N PERI 7-P, sAead 1 M Go 76. it 1i a 09:36:23 a.m. 06-17-2014 446 'Of -4ri PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0109 DATE: 05/20/2014 PROJECT NAME: CENTRAL WELDING SUPPLY SITE ADDRESS: 15700 NELSON PL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division 13 Public Works w I4k �s.z2. ``� FirePrevention Planning Division Structural Permit Coordinator n PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 05/22/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ' Approved with Conditions Corrections Required n Denied (ie: Zoning Issues) (corrections entered in Reviews) DUE DATE: 06/19/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW 0 Staff Initials: 12/18/2013 EMERALD AIRE INC Page 1 of 3 Washington State Department of Labor & Industries EMERALD AIRE INC Owner or tradesperson HAPPE, DOUGLAS A Principals HAPPE, DOUGLAS A, PRESIDENT RIDGE, JOHN PATRICK, VICE PRESIDENT RICHARDS, RON, SECRETARY (End: 06/01/2000) DUPUIS-FRICKE, LINDA, PRESIDENT (End: 12/31/1999) HAPPE, DOUGLAS A, PRESIDENT (End: 12/31/1999) TREMAINE, DAVIS WRIGHT, AGENT (End: 12/31/1999) Doing business as EMERALD AIRE INC WA UBI No. 600 591 552 5108 D STREET NW AUBURN, WA 98001 253-872-5665 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. EMERAAI055BL Effective — expiration 01 /13/1995— 04/01/2015 Bond THE HANOVER INSURANCE COMPANY Bond account no. 1977929 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 01/06/2011 01 /01 /2011 Bond history Insurance American Fire & Casualty Co $1,000,000.00 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600591552&LIC=EMERAAI055BL&SAW= 05/29/2014 RA D G A AC GENERAL INFORMATION PROPERTY TAX NO.: 0005800029 LEGAL DESCRIPTION: MEADER HENRY D-C #46 LOT 1 OF CITY OF TUKWILA SHORT PLAT NO 91-10-SS RECORDING NO 9211101678 SAID SHORT PLAT DAF - POR OF HENRY MEADER D C NO 46 IN SECTION 24-23-04 DAF - BEG SW CORNER OF SECTION 24 TH S 87-48-34 E 1110.88 FT TO MONUMENTED C/L OF STATE ROAD 2-M WEST VALLEY ROAD TH N 07-42-44 W 587,30 FT TH N 87-08-00 E ALG C/L OF S 158TH ST 519.25 FT TO ELY MARGIN OF PUGET SOUND POWER & LIGHT CO R/W TH N 01-21-41 W 18,08 FT TO POB TH N 87-15-22 E ALG NLY MGN OF S 158TH ST 127,95 FT TO WLY MGN OF CHICAGO - MILWAUKEE & ST PAUL RR R/W TH N 03-34-46 E 273,59 FT TH S 87-15-22 W 152,17 FT TO PUGET SOUND POWER & LIGHT CO R/W TH SLY ALG ELY MGN OF SAID R/W 272 FT MORE OR LESS TO POB PROJECT LOCATION: 15700 NELSON ROAD SOUTH TUKWILA WA 98188 PROJECT DESCRIPTION: INSTALL (1) PACKAGED ROOFTOP GAS/AC UNIT AND CORRESPONDING OFFICE DUCTWORK GENERAL MECHANICAL: STANDARDS: EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF ARL, ASME, ASTM, UL, NEMA, ANSI, SMACNA, ASHRAE, MFPA, OTHER APPLICABLE AGENCIES AND AHJ AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY CODES: ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE NATIONAL, STATE AND LOCAL CODES AND ORDINANCES, IN CASE OF CONFLICT BETWEEN THE DRAWINGS/SPECIFICATIONS AND THE CODES AND ORDINANCES, THE MOST STRICT STANDARD (IN THE OPINION OF THE ENGINEER) SHALL APPLY. THE MECHANICAL CONTRACTOR SHALL SATISFY CODE REQUIREMENTS & REQUIREMENTS OF THE CONTRACT DOCUMENTS AS A MINIMUM STANDARD, APPLICABLE CODES:. 2012 IMC W/WASHINGTON STATE AMENDMENTS, 2012 IBC W/WASHINGTON STATE AMENDMENTS. 2012 WASHINGTON STATE ENERGY CODE, GENERAL CONTRACTOR TO PROVIDE ACCESS TO FIRE AND/OR COMBINATION FIRE/SMOKE DAMPERS. HVAC CONTRACTOR: EMERALD AIRE INC 5108 D STREET AUBURN, WA 98001 PROJECT MANAGER: CONTACT: ALLEN STRAUSSER VOICE: (253) 872-5665 FAX: (253) 872-5797 GENERAL CONTRACTOR: WILCOX CONSTRUCTION 234 5TH AVE S EDMONDS, WA 98020 CONTACT VOICE: 425-774-4185 FILE COPY Permit No. M II-{ —D 101 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fiel +, , , y and conditions is acknowledged: By(/ i (,GIN Date: 5 I FP [map City Of "Itikwila BUILDING DIVISION EQUIPMENT SCHEDULES c3 VICINITY MAP: 70ID i n PI WSEC & COMMISSIONING NOTES: THERMOSTATS SHALL BE INTERLOCKED TO PREVENT SIMULTANEOUS HEATING AND COOLING PER WSEC 403. 2. 4. 1, 1 ECONOMIZERS SHALL MODULATE OUTSIDE AIR FROM MINIMUM TO 100% ECONOMIZER CONTROLS SHALL BE CAPABLE OF EVALUATING OUTDOOR AIR COOLING CAPACITY PER WSEC C403, 3, 1, 1 INSULATE REFRIGERANT PIPING PER WSEC TABLE C403.2.8 SEAL DUCTWORK PER WSEC C403. 2. 7, 3 INSULATE DUCTWORK PER WSEC C403, 2. 7. 1 AND C403, 2. 7. 2 COMMISSIONING PER WSEC C408 INCLUDING COMMISSIONING PLAN, SYSTEMS BALANCING, FUNCTIONAL TESTING, CONTROLS TESTING, OPERATION AND MAINTENANCE MANUALS, AND RECORD DRAWINGS, SHALL BE SUBMITTED TO OWNER ON PROJECT COMPLETION, PACKAGED ROOFTOP UNIT # MANUF MODEL # CFM ESP ("WC) ECONO HEATING COOLING ELECTRICAL W(LBS�T CONTROLS NOTES INPUT (MBH) OUTPUT (MBH) AFUE TONS SEER (EER) V/PH MCA MOCP RTU-1 LENNOX ZGA060S4B 2000 0.5 YES 108 84 80 5 13 208/1 41 60 625 7-DAY NOTES: c X? 7 (GGU/lf,lS g,�'/. i�ti��- NA-1Zgta (..,Comic • . LA b . 0 re LIL t (/ i%Kx (J,)/T WEI" Am/Ai C.- L :pranf5 UNIT ON . ROOF. SEE ATTACHED STRUCTURAL CALCULATIONS AND MOUNTING DETAIL GAS PIPING BY OTHERS UNDER SEPARATE PERMIT ALL DUCTWORK IS EXPOSED, R-8 INSULATION WRAPPED AROUND a t r!tJ(r (i t7' A: 2f, rt. ' ' .S-FrCEVAKER 0 G5 RIt.LES .L`Sca . FOR RETUR14 AIR , MOUNTED IN SAME FRAMIED NO INSULATION IN THIPORTION TYPICAL) .two ,. ° A1Cr/4,r.WC. %ice% w PAEL &Tee rest{_ NAttS (7rr) Office TI 1/8" = 1' - 0" HI/L GRILL W. 31 1404 P- 110'0 300 r (\I 0 160 1 C, 4R- I HI/LO GRILLE Fj 104P j 1 0 ' 0 l300I 104P 100 3001 105P 16' 0 1000;. (TYP 2)1 ei/Sr'&i& (1LJJ .© Xc %t ,r a /k; A 7�ij2" ./%/41/ rJr ,t�CG. (A/2_ / - /- qr . Arl / / r_.c__, t'___ limLL5 .c1�L1�r�r� . NE f'71�'CCIP ls. C SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical RElectrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 0..0.32010 2' HVAC LEGEND & ABBREVIATIONS: NECK SItE TYP CFh_ �■GRD IDENTIFIER n u SIDE WALL GRILL SUPPLY GRILLE ® THERMAFUSER ▪ RETURN AIR GRILLE O EXHAUST GRILLE t-4 ... EXHAUST FAN EQUIPMENT TAG O T-STAT CO SENSOR Q OCCUPANCY SENSOR L/V WIRE DUCT RUN 1,47 1' a (— 0 ELBOW --�-0378 REDUCER . . SIDE TAPS 90 ELBOW W/ TURNING VANES IIIII0 FLEXIBLE DUCT —E- E=D MANUAL DAMPER Fn� FIRE DAMPER noSMOKE DAMPER J SD SFD HP HP H TG H TR ID IN KW LAT LBS. LWT MA MAX MBH MIN MS NC N TS OA OBD OC OD PH PSI QTY R/A REF RET RH RLD RPM S/A SEER SH SOV SP TEM P UC V VAV VD VEL W W/ WB W/o SFD aW. ang Miff LAM at REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 3 20114 City of BUILDING SMOKE/FIRE DAMPER MOTORIZED DAMPER BACKDRAFT DAMPER VARIABLE VOLUME/TEMPERATURE HEAT PUMP HORSEPOWER HEATING HEATER INSIDE DIAMETER _INCHES KILOWATT LEAVING AIR TEMPERATURE POUNDS LEAVING WATER TEMPERATURE MIXED AIR MAXIMUM THOUSAND BTU'S PER HOUR MINIMUM MOTOR STARTER NOISE CRITERIA NOT TO SCALE OUTSIDE AIR OPPOSED BLADE DAMPER ON CENTER OUTSIDE DIAMETER PHASE POUNDS PER SQUARE INCH QUANTITY RETURN AIR REFRIGERANT RETURN RELATIVE HUMIDITY RELIEF DAMPER REVOLUTIONS PER MINUTE SUPPLY AIR SEASONAL ENERGY EFFICIENCY RATING, SENSIBLE HEAT SHUT OFF VALVE STATIC PRESSURE TEMPERATURE UNDERCUT DOOR VOLT VARIABLE AIR VOLUME VOLUME DAMPER (HAND OPERATOR) VELOCITY WATT WITH WET BULB WITHOUT IkAlti•--0107 0' 4' 16' SCALE: 1/8" = 1'-0" P:\Working Projects\Central Welding Tukwila AC (214-0506)\Engineering\CAD Drawings\Central PROJECT NORTH RECEIVED CITY OF TUKWILA MAY 2 0 2014 PERMIT CENTER 5/15/2014 Welding Tukwila AC\Sheets\MO HVAC PLANS.dwg z DESCRIPTION - o'Eri DATE PLOT DATE 5/15/2014 ❑ DESIGN DEVELOPMENT DRAWING DATE DATE DATE DATE DATE COORDINATION PERMIT 05, 15, 2014 CONSTRUCTION AS BUILT U J 0 z_ n J LIJ J CY i— LLJ U Iw J 1= O 0 15700 NELSON TUKWILA WA 98188 z LJ -J CD m DRAWN BY: HVAC PLANS SCALE: AS -NOTED MO 214-0506 •