Loading...
HomeMy WebLinkAboutPermit M14-0119 - FAIRWAY CENTER - BUILDING B - ROOFTOP NATURAL GAS HEATING AND AIR CONDITIONING UNITSFAIRWAY CENTER BUILDING B 14240 INTERURBAN AVE S M14-0119 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov MECHANICAL PERMIT 3365901881 14240 INTERURBAN AVE S Project Name: FAIRWAY CENTER - BUILDING B Permit Number: M14-0119 Issue Date: 7/2/2014 Permit Expires On: 12/29/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BELLTOWN INVESTMENT PARTNER 2505 2ND AVE #520 , SEATTLE, WA, 98121 ADRIANA BONILLA 3132 NE 133 ST, SEATTLE, WA, 98125 PSR-HVAC & MECHANICAL SERVICES PO BOX 27073 , SEATTLE, WA, 98165 PSRHVMS924JT Phone: (206) 367-2500 Phone: (206) 367-2500 Expiration Date: 4/30/2016 DESCRIPTION OF WORK: RE[PLACE (2) ROOFTOP NATURAL GAS HEATING/ELECTRIC AIR CONDITIONING PACKAGE UNITS Valuation of Work: $32,495.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $624.78 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: Permit Center Authorized Signature: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 DateT7 ' L I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and a$r9e-to thes att ed to this permit. Signature: Print Name: () 4'6'D rOc/ry/06°405 Date: 7/Z. /2.09 C/, This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 12: Manufacturers installation instructions shall be available on the job site at the time of inspection. 21: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 16: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 17: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 18: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 19: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 15: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 20: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 13: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Project No'.`:< Date Applieafion Accepted Date 'APP, licatlon:x P MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION. King Co Assessor's Tax No.: 3365901881 Site Address: 14240 Interurban Avenue South Suite Number: Floor: Roof Tenant Name: Fairway Center, Building B ;:PROPERTY; OWNER Name: BELLTOWN INVESTMENT PARTNER Address: 14220 INTERURBAN AVE S 98168 City: Tukwila State: WA Zip: 98188 CONTACT PERSON -`person receiving. all project. :}e0i2iiiiii atl.on Name: Adriana Bonilla Address: 3132 NE 133rd Street City: Seattle State: WA Zip: 98125 Phone: (206) 367-2500 Fax: (206) 368-6856 Email: adriana.bonilla@psrmechanical.com New Tenant: ❑ Yes I..No 'MECHANICAL;CON)MCTOR INFORMEI@IONS Company Name: PSR Mechanical Address: 3132 NE 133rd Street City: Seattle State: WA Zip: 98125 Phone: (206) 367-2500 Fax: (206) 368-6856 Contr Reg No.: PSRHVMS924JT Exp Date: 04/30/2014 Tukwila Business License No.: 602811195 Valuation of project (contractor's bid price): $ • 32,495 Describe the scope of work in detail: Replace 2 RTUs natural gas heating/electric air conditioning package units. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric m Gas Other: H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 0 AU.IHORIZED AGENT: Signature: Date: 06/09/2014 Print Name: Adriana Bonilla Day Telephone: (206) 367-2500 Mailing Address: 3132 NE 133rd Street H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Seattle WA 98125 City State Zip Page 2 of 2 DESCRIPTIONS PermitTRAK Cash Register Receipt City of Tukwila ACCOUNT QUANTITY PAID $624.78 M14-0119 Address: 14240 INTERURBAN AVE S Apn: 3365901881 $62478 MECHANICAL $600.75 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $448.10 PLAN CHECK FEE R000.322.102.00.00 0.00 $120.15 TECHNOLOGY FEE $24.03 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2320 R000.322.900.04.00 0.00 $24.03 $624.78 Date Paid: Tuesday, June 10, 2014 Paid By: PSR MECHANICAL Pay Method: CHECK 013016 Printed: Tuesday, June 10, 2014 11:12 AM 1 of 1 SYSTEMS '4i" 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. , n CITY OF TUKWILA BUILDING DIVISION Cr 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 M 14 -4'lq Project: Type of Inspection: Address: 1.4.-4 p ;;At) -'et. Date Called: .S a' \ ()1.�e. S LX 9)I•J Special Instructions: -- f 1 /. Date Wanted: j a�tn> f — %4 p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: in 'k _ ^.�i' .S' i)?.CMr (stl1 0 fa// 1 i V r.. Inspector: '' ^. Date: -it 14 0 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit /11 1 LO/ i 9 INSPECTION NO. PERMIT NO. Oti CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 -ft. 3 Proj ct: r `..— t-{1r A- (e_nf Y� Type of Inspection: / tL14, FATAL_ Address. 14 4140 _c ATUvr A Date Called: Ai Special Instructions: // C`n �,, 4 � 6 \t Date Wanted: f 0 — / a.m. -� I p.m: r , 4 Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 6 f ,r 1 f Inspe tor: Date t( -I4- n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. �rZ INSPECTION RECORD Retain a copy with permit INSPECTION NO. _ PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Gam-' 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 M tL --00 Project: , f -A : ! i41 ..J L- eJ Type of insp ction: M e. (An ; NJ A 1,. Address: Ar, tA-A, / 24fJ 0 Date Called: _ 5 1--1 J fRP .. G\ 1 _bD4-4JA' ..L Special Instructions: /!r i s\ P4/i l �,., 1 ' @� � � Date Wanted _ ' j m Requester: (� Phone No: i L Approved per applicable codes. t" Corrections required prior to approval. COMMENTS: AWN, N � . .(C.' aJ J Inspector Date: 4 REINSFsECTION FEE REQU.JRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTI N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 MN -gig Pro'ec - ,fii li''' /^ C rl�lir Type of In 'p'ection: �� C7�fil ". / 1 / Addrgss� /� ; (� Date Called: (/ SpelcialInstructions: % / �.�j (iif " Date} tapted /� a.m. 4_� p.m. Requester: / Phone 2-a r 5-0— _ n?747/ Approved per applicable codes. r Corrections required prior to approval. COMMENTS: /) Inspector:// L' .4AO Date: i / f REINSPECTION FEE R UIRED. rior to next inspection, fee mu4te paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER fri/��� LV--/ PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 4443Andover Park East, Tukwila, Wa. 98188 206-575-4407. Project: Type of Inspection:///... //�% Address: Suite / /L V/0 Contact Person: ` 2 4S #: /f . Special Instruction : Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS:, //.ew 1 fi .- / 7 %D _---4ge-- A55 2 UA., 71S / { Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: �r3 Date: /o/zi// L-( Hrs.: /. v V$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from t e City of Tukwila Finance Depa-tmet. Call to schedule a reinspection. Billing Address `1' Attn: J Company Name: f,,/.,/ Afmt �I!( Address: ).O30 // ,'fro2i WAA/ City: � ek 7 d State: L&) 4- Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 CWA CONSULTANTS, P.S. STRUCTURAL ENGINEERING BUILDING CODE CONSULTANTS 8675 E. Caraway Road; Port Orchard, WA 98366 (360) 871-5433 FAX: (360) 871-5633 E-Mail: chuck@cwaconsultants.net cwaconsultants.net June 9, 2014 HVAC Roof Attachment 195R HVAC and Mechanical Services Fairway Center Unit 56 Seattle, WA Fp=(0 4.apxSJ2)(1+2z/h) Wp Rp/Ip ASCE 7 Table 13.6-1 ap=2.5, Rp=6.0 5Ds = 0.846 z/h =1.0 max Connect new metal curb ADAPTER of HVAC unit to existing wood framing #12 screws (6 min) 0 24" oc at perimeter Connect HVAC unit to curb per manufacturer's installation instruction Fp = .(0 4x2 5x0.8_4.6x3.0) Wp = 0.423 Wp 6.0/1.0 Fp max =1.6x0.846 =1.35 Fp min = 0.3x0.846 = 0.25 Use 0.423 Carrier 48HCDD1752 Wp Fp@CG—�¢ 4x6 at curb support with 5A48 top flange hanger each end (Existing) Existing 16" TJI Type Roof REVIEWED FOR Jo CODE COMPLIANCE APPROVED Ex iit�ii� • wad JUN 2 7 2014 City of Tukwila G DIVISION sts ting 8-3/4"x36" Glu-Lam HVAC Unit — Wt = 2303# + 520# Adaptor Curb L=128" W=86" H=49" Cg = (36"x 2303 + 10 x 520)/ 2823 = 31" above base (wt avg) Fp = 0.423x2823 =1194# Wind X = .85x1.3x(4.0x12.5)(13) = 718# Wind Y = .85x1.3x(4.0x5.0)(13) = 287# USE 1194# for all °ales OT (worst case)=1194x31 — 0.6x2823 x (86-48) =-27350"# no net overturning RECEIVED CITY OF TUKWILA Attachment HVAC Unit connection to existing wood framing- #12 Wood screws Cap = (130x1.6)# x 6 (min) =1248# min > 1194# OK Max Corner Weight = 565# (4x6 span 4' OK) JUN 1 0 2014 PERMIT CENTER R:DocumentsONord FilestPSRIPSR Fainivay Center HVAC Install tion B6.doc Performance Summary For B6 Project: —Untitled2 Prepared By: 05/09/2014 07:24PM Part Number:48HCDD97B2A6-6DOHO ARI EER• 12.00 IEER' 13.5 Base Unit Dimensions Unit Length' _ 127.9 in Unit Width' 86.4 in Unit Height. 49.4 in Operating Weight Base Unit Weight 1892 Ib RA Smoke Detector 5 Ib Medium Static Option - Vertical Models' 5 Ib Temperature economizer with centrifugal power exhaust (Vertical Air Flow Only)' 371 Ib 2-Speed Fan Controller (VFD) and HACR Breaker 30 Ib Total Operating Weight* Unit Unit Volta ge-P hase-H ertz• 460-3-60 Air Discharge. Vertical Fan Drive Type. Belt Actual Airflow' 6000 CFM Site Altitude' _ 0 ft Cooling Performance Condenser Entering Air DB• 95.0 F Evaporator Entering Air DB• 80.0 F Evaporator Entering Air WB: 67.0 F Entering Air Enthalpy:. - 31.44 BTU/Ib Evaporator Leaving Air DB• __...58.6 F Evaporator Leaving Air WB• 57.4 F Evaporator Leaving Air Enthalpy. 24.65 BTU/Ib Gross Cooling Capacity 183.38 MBH Gross Sensible Capacity' 138.50 MBH Compressor Power Input* 12.43 kW Coil Bypass Factor 0.198 Heating Performance Heating Airflow- 6000 CFM Entering Air Temp• 70.0 F Leaving Air Temp• 97.5 F Gas Input Capacity. . 176.0 / 220.0 MBH Gas Heating Capacity. 178.00 MBH Temperature Rise• 27.5 F NOTE- Second Stage Supply Fan External Static Pressure. 0.90 in wg Options / Accessories Static Pressure EconoMi$erlV / EconoMi$er2' 0.06 in wg Power Exhaust (Fan Data Includes Drop) Total External Static. 0.96 in wg Fan RPM• 838 Fan Power3.10 BHP NOTE• Selected IFM RPM Range: 679 - 863 Power Exhaust Return Duct Static* _ 0.20 in wg Max. Air to Exhaust* 5150 CFM Packaged Rooftop Builder 1.39i Page 27 of 32 ZE 10 9Z e6ed !6£' L Jap!!ng doLlooH pe6e>!0ed 33a 951Z033HO 1Y3H SV9 HUM 9NI1000 1VDINI)313 3N0Z 319NIS Ll )HS1 t111013111 Ol/ZI/L0 UM 2 SO 1311S 1HOIa 201/ 918 JD 401111910 ♦ '0 1.1.I090 /0 93193) S '2 0001$01HI05'13 )117 HI 70N0I1N3N10 '1 c13100 /NXONS 10X1 9011)3NX0) Sv9 144 II-.I/t J MI110 3100130NO3 192 11•.//0 3 31011 OHMS 10E1403 01314 1221 110 .9/1 0 1501)gn4 ruins 43904 01311 1201 510 .0/9 0 3 1000)0104 A1dd5S 9390d 01311 CI(/ VIO .S 0 10033080 114400 436101 0131) 153 530 .9/5 l Y 03110 5011336003 1612E1 S•2 Y1[ LG4 1NOad 2/1211 31➢9vN 9NLJ11 VOW IIYN AI 130YXM3 83 j HI .01 91Y 6ldens OODH 1Y)I133A 3Yf1Nl 1IY If521 j. 000N 301 Hill ➢tLi➢➢-➢i (1 811 11 8731 y O 0 201J 1SAYX13 tlINOd 91Y _ Y 3013100 / 1)2' Ill iZ3� yy�I 71 11.i. 11 01 7i1199Y➢ 24 ,1111,1 B IICI N IW6y411191 �dI X 1' M pIN.IJ Ip, 4A'� M 5 333V 'l0) 80010 031tl11J �' 17NYd 00333Y 10tl1tl03 V.E1 ei 1 epp9til IP,9! !hll - 111Yd SS3))Y 939019 6000NI f I[9/1 6l Jr S310N (ID YIO .2 d01 1001304 12£1 YI0 .1/1 1 1961 (CBI OIL-C I/1-C 119t1 2/1.9 (0CU 411.12 162E1 911. 21 9/121 Ill 9 11911 0/1-I IOC111 9/I.9/ 910.19 (1S11 9/1.0 nn ��}}11 '1)141113i1ftt0 ,9�3�1 1/1U1 2169 r W f3!9110191!611101141i6INU1 I04q!i813 1J100 1tgW1W9W 20 117/014 T13600Y11N1 uxi 93108v3 u '31132l03 0310010X/1331 coo. 101 •0v 0311X0 11511 //1-9 IS9Cl1 tit S )1 Nod 9/ I- I1 9ICri 1110011d01 006311 21Y S000100 (12111 99 l•-- 16991 1/l-61 4 33211000033 O/Y 1110 N9n134 11186211014 110411 I/(-S1 16021 Y011Y)01 13381103110 1Y)191)313 t2211 1d31 12211 //C-1 Memo rem N0:13 /A 39HYHOS10 IYLY®H(x0 ICI13 9/S-S 11131301/0 N31411 LYO33 0/M 308Ys 5SI0 1V101OZl ) 16921) NOVB Olt Os (11)1 2/1-1C tfiS1 1191 9/0-62 Ill•S 15C11 1/1-S 19011 I/C-62 11111 0/3-S 8321110.80l 1OOMIY 1001110 1010021800 .. rf. . — C . . L1dd05 I 1611102100H Ifi14'I IIIN6ull CIYY01@!9' ' IB I� o nA,du9d 3 iil1�3¢91 �Illlli l ' �1199 :dI . L79 s:' t1;9 I - ! • 12011 971-SL +^, WdFZ:LO b L OZ/60/90 98 101 6upteJQ pail ne :leg pa.ledald ZPaimun— :pa(wd 17, I1 4x6 AHU CURB SUPPORT FRAMING CONNEC TO TJI WITH JOIST HA I GER 1 ;1 s 6' 0' STEEL COLUMN WITH BEAM POCKET TO SUPPORT GLU—LAM BEAMS, TYP 39"xB-3/4" GLU—LAM BEAM. TYP Unit 0B-6 16' TRUSS JOIST (TJI) 48" OC. SUPPORTED BEAM W/ JOIST HANGERS P) A-. _IL Certified Drawing for B6 Project: Untitled2 Prepared By: 05/09/2014 07:24PM UNIT STD UNIT WEIGHT LBS. 1892 KG. TNT CORNER CORKER COME WEIGHT IA1 WEIGHT 181 WEIGHT ICI LDS. 401 2DK KG, 211 MINER WEIGHT III LOS. 505 KG. 23D 48 112191 C.G. T SI 3/8 11711 1 STANDARD UNIT HEIGHT IS WITH LOW GAS HEAT AND WITHOUT PACKAGING. FOR OTHER OPTIONS AND ACCESSORIES, REFER TO THE PRODUCT DATA CATALOG. 5" '1) 6 '�- a Z TOP 9 peinuommissais .1 0 l UNITED I.N. III MI TECHN010GI(S 111I.ISB. At CARRIER luxe 1'rui'all1 i IIi11TN 0*1(M1. W N11 Y11NC1T KA1111n IVIOHIl101 W 11[f1 11A11i1% UI 1001 CIIS 11[1 III 1RN1lllU2 111T /CA*OS14110C 0* Itt[ITRICC DC CDIIRIC1. CORNER B CORNER C FRONT UM 07/12/10 111CIC11C1 48HC 17 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 50HE502150 ICI Packaged Rooftop Builder 1.39i Page 26 of 32 Notes: 1. 1.5" ADDED TO OLD CURB O.D 2. MATERIAL: 16 ga. GALVANIZED STEEL 3. GASKET PROVIDED WITH CURB 4. INSULATION: 1" 1 1/2 LB DENSITY a 9 3/16" r 2"TYP 50" 241/16" f+- 77 7/8" DIMENSIONED AND TOL[RENDED PER ANSI 111.04.1112 Attn: Tag: Approval: 14 7/8" 121 5/8" 3" 5" EXISTING CURB LAYOUT 70 7/16" 56 12" 361i/16" 2412"�{ 70 3/4" RETURN SUPPLY' 77 3/4" 2 1/4" REV. REVISIONS DESCRIPTION DATE APPROVED 2 INITIAL DRAWING 7/30/09 MWG 3 UPDATED TOP BRACES 12/2/11 00 RETURN AIR VERT A.I. (4X) SUPPLY AIR A.I. CROSS (UNDER COVER) INSULATED PANELS CD! Model Existing Unit Number New Unit Tonnage Suy Pressure Drop Return Pressure Drop 1-4010-4159 CARRIER CARRIER 15 0.032"H20 0.088"H20 CURB WEIGHT Met) APPROVALS DATE 520.54 °" ODFVnren *VERIFY EXISTING CURB OD *VERIFY SUPPLY AND RETURN OPENING Friday. December02, 20111 *NOTE ANY CHANGES ie. •,;;„rr 17660 TYLER ST NW CURB SHOWN IS CDI STANDARD CONFIGURATIONCDI RESERVES THE RIGHT TO CHANGE *CALL WITH ANY QUESTIONS ELK RTVER, MN 66330 MUST BE NOTIFIED PRIOR O PLACING AN ORDER. LAYOUT WITHOUT NOTIFICATION. IF CURB IS ED IN A DIFFERENT CONFIGURATION CDI FAX BACK IF DRAWING IS OK AS IS ,J,_, CDI ((763 391-7861 '^, l®E3 (763)3E1.7E61 44:40 PM lam 1-4010-4159 QUOTE #: 1-4010-4159 mua 1:30 J .at 1 OF 3 CWA CONSULTANTS, P.S. STRUCTURAL ENGINEERING BUILDING CODE CONSULTANTS 8675 E. Caraway Road Port Orchard, WA 98366 (360) 871-5433 FAX: (360) 871-5633 E-Mail: chuck@cwaconsultantsret June 9, 2014 HVAC Roof Attachment FSR HVAC and Mechanical Services Fairway Center Unit 54 Seattle, WA Fp=(0.4apx5R5)(1+2z/h) Wp Rp/Ip ASCE 7 Table 13.6-1 ap=2.5, Rp=6.0 5Ds = 0.846 z/h =1.0 max Connect new metal curb of HVAC unit to existing wood framing #12 screws (4 min) @ 24" oc at perimeter Connect HVAC unit to curb per manufacturer's installation instruction Fp = .(0.4x2.5x0.8_4.6x3.0) Wp = 0.423 Wp 6.0/1.0 Fp max =1.6x0.846 =1.35 Fp min = 0.3x0.846 = 0.25 Use 0.423 Fp@CG—�� Wp 4x6 at curb support with 5A48 top flange hanger each end (Existing) Existing 16" TJI Type Roof Joists Existing 8-3/4"x36" Glu-Lam Carrier 48HCDD1152A6-6U0H0 HVAC Unit — Wt = 1298# + 110# = 1408# total including curb L = 88" W = 60" H = 49" Cg = 22" + 14" curb = 36" above base Fp = 0.423x1408 = 596# Wind X = .85x1.3x(4.0x6.5)(13) = 373# Wind Y = .85x1.3x(4.0x4.0)(13) = 172# USE 596# for all calcs OT (worst case) = 596x36 — 0.6x1408 x (60-34) _ -509"# no net overturning Attachment HVAC Unit connection to existing wood framing- #12 Wood screws Cap = (130x1.6)# x 4 (min) = 832# min > 596# OK Max Corner Weight = 405# (4x6 span 4' OK) M 113P 0 I 1 ? R:\Documents\Word Files\PSR\PSR Fairway Center HVAC Installation B4.doc EVIEWED FOR ODE CMPLIANCI APPROVED JUN 2 7 2014 CityGTukwila DIVISION RECEIVED CITY OF TUKWILA JUN 1 0 2014 PERMIT CENTER Performance Summary For B4 Project:-Untitled2 Prepared By: 05/09/2014 07:24PM Part Number:48HCDD11 B2A6-6U0H0 ARI EER• 12.00 JEER:_ 14.3 Base Unit Dimensions Unit Length' 88.1 in Unit Width. 59.5 in Unit Height. . 49.4 in Operating Weight Base Unit Weight* 1099 Ib RA Smoke Detector 5 Ib Medium Static Option - Belt Drive. 15 Ib Temp Low Leak Economizer w/Baro Relief 74 Ib 2-Speed Fan Controller (VFD) and HACR Breaker 30 Ib Accessories Power Exhaust System' 75 Ib Unit Unit Voltage -Phase -Hertz' 460-3-60 Air Discharge- Vertical Fan Drive Type- Belt Actual Airflow. 4000 CFM Site Altitude' 0 ft Total Operating Weight. (1298 lb Cooling Performance Condenser Entering Air DB• 95.0 F Evaporator Entering Air DB• _ 80.0 F Evaporator Entering Air WB. 67.0 F Entering Air Enthalpy 31.44 BTU/Ib Evaporator Leaving Air DB' 58.6 F Evaporator Leaving Air WB• 57.6 F Evaporator Leaving Air Enthalpy. 24.78 BTU/lb Gross Cooling Capacity- 119.85 MBH Gross Sensible Capacity- 92.51 MBH Compressor Power Input. 8.44 kW Coil Bypass Factor 0.250 Heating Performance Heating Airflow' 4000 CFM Entering Air Temp. ...... ............ _-__70.0 F Leaving Air Temp' 104.3 F Gas Input Capacity- _ 120.0 / 180.0 MBH Gas Heating Capacity. 148.00 MBH Temperature Rise. 34.3 F NOTE Second Stage Supply Fan External Static Pressure. 1.00 in wg Options / Accessories Static Pressure EconoMi$erlV / EconoMi$er2• 0.20 in wg Power Exhaust. (Fan Data Includes Drop) Total External Static. 1.20 in wg Fan RPM- 1042 Fan Power 2.93 BHP NOTE:. Selected IFM RPM Range: 838 -1084 Power Exhaust Packaged Rooftop Builder 1.39i Page 17 of 32 Project:-Untitled2 Prepared By: Certified Drawing for B4 05/09/2014 07:24PM NOTES: 1. INN1RS111EAII 1ILLIHCT000. NENSIONS 2. IS CENTER OF GRAVITY 3. NO, 0I1ECT(ON Of AIR FLOW FILTER ALESS LANES 0[SPOSABLE FILTERS) (DISPOSABLE • CONDENSER INDOOR COIL ACCESS PANEL COIL -- • • • oogl RACK 3-1/4 (951 Packaged Rooftop Builder 1.39i OPTIONAL FACT011 INSTALLED CONVENIENCE •OUTLE1 59 1/2 (15101 LEFT "411[it2114' 111 I C 13O1)(2, 91 11 3/4 1296I 4-.S18 11111 ECTRICAL DISCONNECT LOCATION: 3R (9131 49-SIG E12531 2-5/8 [6TIP CURB WIDTH NFU -ENE -BASES -5 ...,...0 APT 29 5/R -- (1111 CONTROL BOX ACCESS PANEL OPTIONAL FACTORY INSTALLED DISCONNECT HAN)LE--\, F E ALT. CONDENSATE DIAIN OPENING IN DASEPAN 1-3/8 (214) BO 1/8 (22361 FRONT UNITED (.0. 1AE 5000 TECHNOLOGIES 1T*ACOTE, CARRIER 10051 rill ISOP[IT TA 11[ P501E/11 OT GAit22 CONPIRATIIN HIS 11 0l{l10El6 11a TIE 1RPA110 C01011105 TROT TAT C0!RIITA sAA q1 A 015(1010 a 0110 511R0R1 IANAIDI C011P0005110 / 1R111U1 0CAt1Ai. l2OF0 IIIII 1OI0T01ITIOR Pall YrAl�Ti{AI( 09 AK1(PTAl9I CF CD111An. 40 1/8 110261 14—.- I3511 --- -25.1 /2 -- (6451 INDOOR BLOWER ACCESS 2D-3/4 15261 12.5/6 0211 AO 3/B (10271 3-1/4 1631 FLUE ROOD 11.1/1 (3531 15.3/0 11461. 4101 RETURN AIN SUPPLY jR-I,4 (159) 2-7/0 (731 /-3/8 (IIII CONNECTION STIES A 1 3/8' 137) DIA FIELD POWER SUPPLE ROLE / 12 1/2' 1641 DIA POWER SUPPLY KNOCKOUT C 11 3/4' (51) DIA GAUGE ACCESS PLUG 1 IIIB' 1221 0(A FIELD CONTROL MIRING HOLE E 3/4'-14 MIT CONDENSATE DRAIN F 1/4'-14 NPT GAS CONNECTION G 2' 011 DIA POWER SUPPLY KNOCK -OUT YNRU-THE-BASE CHANT IMF ROLES REQUIRED FOR USE CKR000NA002A01,004A 1 TNAEAOED CONDUIT SIZE WINE 15E REO'0 HOLE S12ES (NAI.) W 1/2' ACC. 1/8' (22.21 K 1/2' 242 1/6' (22.21 I 1 114' II62,004) POWER 1 3/4' (11.41 LA 10041 114' OPT GAS 1 5/6' 241.31 FOR 'TNRU-TNE-OASEPAN' F CROAT OPTION. FITTINGS FOR01LT s, Y. 8 Z ARE PR0V10E0 I (4021 PROVIDES 3/4' PLY YNRU CURB FLANGE 6 FITTING. 52.518 2321) E STD. -- CONDENSATE DRAIN .--- 2B-3/8 —'-' 17201 SUPPLY AIR • 36-3/8'. II 51 \VVV+++ RETURN AIR Jr ` 5.3/4 (T461 ILTER _ BAROMETRIC (1066) RELIEF FLOW RIGHT RETURN AIR TA NSTDE 101 10/19/12 Evomou 04-23-12 48HC-D11, 48HC-D12 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48TM502926 C Page 15 of 32 Certified Drawing for B4 Project:-Untitted2 Prepared By: 05/09/2014 07:24PM OAST STD. UNIT WEIGHT 1 CORNEA WEIGHT (A1 CORNER WEIGHT f01 CO NER WEIGHT ICI CORNER WEIGHT 101 C.G. LIS. NG. LBS. KG. L85. KG. L85. 38. 1.63. AG. 'BAC•D12 1090 195 311 142 162 11 211 96 10$ IA1 30 1F6 11651 33 5/8 18551 20 3// (5281 t65C•011 1010 135 311 142 162 14 211 93 405 151 30 II3 0411 33 5/8 18551 20 3/4 15281 CORNER A UNITED 1.8, 181 Q40 TECHIOLOGIES 1104-11I. n CARRIER URA1. 1m1/11 SS lINllYPIS DUN MANNA Fret 2G1101A110N'D YIIrTON in M tjtiitt 0OI11Ct2r161 [111[1t C01AIr1EN TART 1Nt ro C3Fro8(1NWr 1211111 0 6 A91KI T01TD1[I 401111i1dNuiR't�OR 1clurua a coluAcl. STANDARD SNIT WEI6NT IS WITH 1C► 6A5 HEAT AND WITHOUT PACWAGIKG, TOR OTHER OPTIONS AID ACCESSORIES, REFER TO THE PRODUCT DATA CATALOG. CORNER D LI TOP . , { } $fo0 C. i l I:=1 : 00 FRONT CORNER 8 CORNER C SWAT 2 OE 2 MU 10/19/12 RIR1112*1 04-23-12 48HC-011, 48HC-D12 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48714502926 Packaged Rooftop Builder 1,391 Page 16 of 32 #230 4x6 AHU CURB SUPPORT FRAMING CONNECTED TO TA MTH JOIST HANGER 6'-0" APP OX. —7/ IA 3O"x8-3/4" GLU—LAM BEAM, TYP Unit i8-4 #224 16" TRUSS JOIST (TJI) ® 48" OC. SUPPORTED ® BEAM W/ JOIST HANGERS (TYP) 1 STEEL COLUMN MTH BEAM POCKET TO SUPPORT GLU—LAM BEAMS, TYP `1' 4 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0119 DATE: 06/10/14 PROJECT NAME: FAIRWAY CENTER - BUILDING B SITE ADDRESS: 14240 INTERURBAN AVE S X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: me (D10-M Building Division Public Works Fire Prevention Structural n Planning Division Permit Coordinator it PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 06/12/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Corrections Required (corrections entered in Reviews) Notation: DUE DATE: 07/10/14 Approved with Conditions Denied (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PSR-HVAC & MECHANICAL SERVICES Page 1 of 2 4.4 Washington State Department of Labor & Industries rPSR-HVAC &MECHANICAL SERVICES Owner or tradesperson O'MALLEY, JAMES J Principals O'MALLEY, JAMES J, MEMBER HOGERTY, REAGAN P, MEMBER BAVINS, NEIL JONATHAN, MEMBER O'DONNELL, STEPHEN 0 (End: 04/12/2012) RIST, STEVEN L (End: 04/12/2012) Doing business as PSR-HVAC & MECHANICAL SERVICES WA UBI No. 602 811 195 PO BOX 27073 SEATTLE, WA 98165 206-367-2500 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. PSRHVMS924JT Effective — expiration 04/30/2008— 04/30/2016 Bond International Fidelity Ins Co Bond account no. 0649932 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 03/28/2014 03/26/2014 Expiration date Until Canceled Insurance Zurich American Ins Co $1,000,000.00 Policy no. GL0488649704 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602811195&LIC=PSRHVMS924JT&SAW= 07/02/2014 LEGEND ABBREVIATIONS 4. 0 RISE t-CC-t t RISE 24x12 24x12 10x8 I/\ x o I e - I0 t } } TV 0 1,71 CUBIC FEET PER MINUTE CENTER LINE ROUND DUCT INDICATOR OVAL DUCT INDICATOR THERMOSTAT LINE DIRECTION OF RISE FOR DUCT DUCT (FIRST FIGURE DENOTES VIEW SHOWN) SINGLE LINE DUCTWORK INDICATES DUCT WITH VIEW DIMENSION LESS THAN 12 INCHES SUPPLY OR EXHAUST TAKEOFF SUPPLY DUCT TURNING TOWARD, UP SUPPLY DUCT TURNING AWAY EXHAUST DUCT TURNING TOWARD, UP EXHAUST DUCT TURNING AWAY ROUND DUCT TURNING TOWARD, UP ROUND DUCT TURNING AWAY OVAL DUCT TURNING TOWARD, UP OVAL DUCT TURNING AWAY CONICAL WYE CONICAL TEE VOLUME DAMPER(VD) FIRE SMOKE DAMPER(FSD) MOTORIZED DAMPER(FD) FIRE DAMPER(FD) 3-WAY SUPPLY DIFFUSER 2-WAY SUPPLY DIFFUSER 2-WAY CORNER SUPPLY DIFFUSER 1-WAY SUPPLY DIFFUSER DOUBLE LINE, LINED DUCT/ ACOUSTIC DUCT RECTANGLE TO RECTANGLE FITTING (RIGHT) RECTANGLE TO RECTANGLE FITTING (LEFT) ROUND TO ROUND HIGH/ MEDIUM VELOCITY FITTING ROUND TO ROUND FITTING TO SUPPLY DIFFUSERS(DOUBLEULINED�CT TAKE -OFF, LOW VELOCITY (PRESSURE) ROUND DUCT TAKE -OFF, TO SUPPLY DIFFUSER (SINGLE LINED) RECTANGLE/ ROUND RADIUSED ELBOW DUCT RECTANGULAR 90' ELBOW W/ TURNING VANES TYPICAL ECCENTRIC CONICAL DUCT REDUCTION FITTING CONCENTRIC CONICAL DUCT REDUCTION FITTING RECTANGLE TO ROUND FITTING SOUND ATTENUATOR TURNING VANES FLEXIBLE DUCT THERMOSTAT OR TEMPERATURE SENSOR THERMOSTAT OR TEMPERATURE SENSOR(CEILING) DUCT SMOKE DETECTOR SQUARE SUPPLY AIR DIFFUSER ROUND SUPPLY AIR DIFFUSER 2'x2' RETURN AIR GRILLE 2'x4' RETURN AIR GRILLE SIDEWALL SUPPLY AIR GRILLE OR REGISTER SIDEWALL RETURN/EXHAUST AIR GRILLE OR REGISTER AC ACF ADA ADJ AFF AL ALIGN AP APPROX ARCH ASME AVG BFF BHP BLDG BOD BOP BTU BTUH BV CD CFM CG CI CLG CO CONN CONST CONT COORD CORR COTG CU FT CU IN DB DCVA DEG DET DIA DIFF DIM DISCH DN DR DS DSD DWG EA EAT EF EFF EG ELECT ELEV EMERG EN T ESP EXH EXIST EXP FC FCO FD FDC FI O FLA FLEX FLR FOB FOIC FOT FPM FPS FSD FT FU G GA GAL GALV GEN GND GPH GPM H HP HR HTG HVAC HZ IBC ID IE IMC IN INSUL IW AIR CONDITIONING AIR CURTAIN FAN AMERICAN DISABILITIES ACT ADJACENT;JADJUST; ADJUSTABLE; ABOVE FINISHED FLOOR ACOUSTIC LINED ALIGNMENT ACCESS PANEL APPROXIMATELY ARCHITECTURAL AMERICAN SOCIETY OF MECHANICAL ENGINEERS AVERAGE BELOW FINISH FLOOR BRAKE HORSEPOWER BUILDING BOTTOM OF DUCT BOTTOM OF PIPE BRITISH THERMAL UNIT BRITISH THERMAL UNITS PER HOUR BALANCING VALVE CEILING DIFFUSER CUBIC FEET PER MINUTE CEILING GRILLE CAST IRON CEILING CLEANOUT CONNECT; CONNECTED; CONNECTION CONSTRUCTION CONTINUOUS; CONTINUATION COORDINATE CORRIDOR CLEANOUT TO GRADE CUBIC FEET CUBIC INCHES DRY BULB TEMPERATURE DOUBLE CHECK VALVE ASSEMBLY DEGREE DETAIL DIAMETER DIFFERENTIAL DIMENSION DISCHARGE DOWN DRAIN DOWNSPOUT DUCT SMOKE DETECTOR DRAWING EACH ENTERING AIR TEMPERATURE EXHAUST FAN EFFICIENCY EXHAUST GRILLE ELECTRI CAL ELEVATION EMERGENCY ENTERING EXTERNAL STATIC PRESSURE EXHAUST EXISTING EXPANSION FAHRENHEIT FANCOIL FLOOR CLEANOUT FIRE DAMPER FIRE DEPARTMENT CONNECTION FURNISHED AND INSTALLED BY OWNER FULL LOAD AMP FLEXIBLE FLOOR FLAT ON BOTTOM FURNISHED BY OWNER INSTALLED BY CONTRACTOR FLAT ON TOP FEET PER MINUTE FEET PER SECOND FIRE SMOKE DAMPER FOOT, FEET FIXTURE UNITS GAS GAGE GALLON GALVANIZED GENERAL GROUND GALLONS PER HOUR GALLONS PER MINUTE HEIGHT, HIGH HORSEPOWER HOUR HEATING HEATING VENTILATING, AND AIR ONDITIG HERTZ INTERNATIONAL BUILDING CODE INDIRECT DRAIN INVERT ELEVATION INTERNATIONAL MECHANICAL CODE INCH INSULATE; INSULATION INDIRECT WASTE KW KWH L LAV LAT LB LF LVG MA MAX MBH, MBTU M CA M CC MD MECH MFR MIN MISC MOD MID MTG NC NIC NTS OAC OAT OD OH ORD OA P PD PH POC PRELIM PRESS PRV PSI PSIG RA RD RECIRC RECT REF REG REQD RND RPBP RPM RV SCHED SF SG SO SOV SP SPEC SPECD SST SS STRUCT SWG SWR TBD TEM P TSTAT THRU TOD TOP TP TS TV TYP UPC U TR V VD VEL VERT VOL VTR W WCO WB WEF WG W/ W/O WT KILOWATT KILOWATT HOUR LENGTH LAVATORY LEAVING AIR TEMPERATURE POUNDS LINEAL FOOT LEAVING MIXED AIR MAXIMUM THOUSAND BRITISH THERMAL UNITS PER HOUR MINIMUM CIRCUIT AMPACITY MOTOR CONTROL CENTER MOTORIZED DAMPER MECHANICAL MANUFACTURER MINIMUM; MINUTE MISCELLANEOUS MOTOR OPERATED DAMPER MOUNTED MOUNTING NOISE CRITERIA NOT IN CONTRACT NOT TO SCALE OUTDOOR AIR CONDITIONER OUTSIDE AIR TEMP OUTSIDE DIAMETER; OVERALL DIAMETER OVERHEAD OVERFLOW ROOF DRAIN OUTSIDE AIR PUMP PRESSURE DROP; PIT DRAIN PHASE POINT OF CONNECTION PRELIMINARY PRESSURE PRESSURE REDUCING VALVE POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAGE RETURN AIR ROOF DRAIN RECIRCULATING RECTANGULAR REFERENCE REGULATOR REQUIRED ROUND REDUCED PRESSURE BACKFLOW PREVENTER REVOLUTIONS PER MINUTE RELIEF VALVE DISCHARGE SCHEDULE SUPPLY FA, SQUARE FEET SUPPLY GRILLE SCREENED OPENING SHUT OFF VALVE STATIC PRESSURE SPECIFICATION SPECIFIED STAINLESS STEEL SOIL STACK, SANITARY SEWER STRUCTURAL SUPPLY WALL GRILLE SUPPLY WALL REGISTER TO BE DETERMINED TEMPERATURE; TEMPORARY THERMOSTAT THROUGH TOP OF DUCT TOP OF PIPE TRAP PRIMER TEMPERATURE SENSOR TURNING VANE TYPICAL UNIFORM PLUMBING CODE UP THRU ROOF VENT VOLUME DAMPER VELOCI TY VERTICAL VOLUME VENT TO ROOF WASTE WALL CLEAN OUT WET BULB TEMPERATURE WALL EXHAUST FAN WATER GAGE WITH WITHOUT WEIGHT GENERAL NOTES: GENERAL HVAC NOTES: 1. COMPLETE INSTALLA110N OF THE MECHANICAL SYSTEM SHALL BE PER THE LATEST ADOPTED VERSION OF INTERNATIONAL BUILDING CODE (IBC), INTERNATIONAL MECHANICAL CODE (IMC), WASHINGTON STATE ENERGY CODE (WSEC), UNIFORM PLUMBING CODE (UPC), INTERNATIONAL FUEL GAS CODE (IFGC), INTERNATIONAL FIRE CODE (IFC), NFPA AND HEALTH CODES AND REGULATIONS AS ADOPTED BY THE LOCAL JURISDICTIONS. 2. CONTRACTOR SHALL COORDINATE DIFFUSER, GRILLE AND REGISTER LOCATIONS AND DUCT ROUTING CLEARANCES WITH THE STRUCTURAL, REFLECTED CEILING AND LIGHTING PLANS. 3. MAKE ACCEPTABLE ACCESS PROVISIONS FOR REMOVAL OF FILTER AND MAINTENANCE FOR ALL INDOOR UNITS. REFER TO MANUFACTURER'S INSTALLA110N GUIDE. 4. ALL CONTROL WIRE AND CONDUIT SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE. 5. WHEN MECHANICAL WORK (HVAC, PLUMBING, SHEET METAL, FIRE PROTECTION, ETC.) IS SUBCONTRACTED, IT SHALL B THE MECHANICAL CONTRACTOR'S RESPONSIBILITY TO COORDINATE SUBCONTRACTORS AND THE ASSOCIATED CONTRAC WHEN DISCREPANCIES ARISE PERTAINING TO WHICH CONTRACTOR PROVIDES A PARTICULAR ITEM OF THE MECHANICA CONTRACT OR WHICH CONTRACTOR PROVIDES FINAL CONNECTIONS FOR A PARTICULAR ITEM OF THE MECHANICAL CONTRACT, IT SHALL BE BROUGHT TO THE ATTENTION OF THE MECHANICAL CONTRACTOR. 1. CONTRACT DOCUMENT DRAWINGS FOR MECHANICAL WORK (HVAC) ARE DIAGRAMMATIC AND ARE INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY. 2. LOCATE ALL TEMPERATURE, DEVICES IN DUCTWORK LOCATIONS WITH STRAIGHT SECTION OF DUCT UP AND DOWNSTREAM AS RECOMMENDED BY THE MANUFACTURER FOR GOOD ACCURACY. 3. COORDINATE AND PROVIDE ALL DUCT TRANSITIONS REQUIRED FOR FINAL EQUIPMENT CONNECTIONS TO FURNISHED EQUIPMENT. FIELD VERIFY AND COORDINATE ALL DUCT DIMENSIONS BEFORE FABRICATION. REVIEWED FOR SEI CODE COMPLIANC APPROVED 5. CE s. JUN 2 7 2014 CO 6. THE LOCATIONS OF ALL ITEMS SHOWN ON THE DRAWINGS OR CALLED FOR IN THE DOCUMENTS THAT ARE NOT DEFINITELY FIXED BY DIMENSIONS ARE APPROXIMATE ONLY. THE EXACT LOCATIONS NECESSARY TO SECURE THE BEST CONDITIONS AND RESULTS MUST BE DETERMINED BY THE PROJECT SITE CONDITIONS AND SHALL HAVE THE APPROVAL OF THE ENGINEER BEFORE BEING INSTALLED. DO NOT SCALE DRAWINGS. EQUIPMENT, DUCTWORK, ETC., SHALL BE SUPPORTED AS REQUIRED TO PROVIDE A VIBRATION FREE INSTALLATION, AND MICALLY BRACED AS REQUIRED. PROVIDE VIBRATION ISOLATION FOR ALL MECHANICAL EQUIPMENT TO PREVENT TRANSMISSION VIBRATION TO BUILDING STRUCTURE. TAIN ITEMS SUCH AS RISES AND DROPS IN DUCTWORK, ACCESS DOORS, VOLUME DAMPERS, ETC. ARE INDICATED ON THE TRACT DOCUMENT DRAWINGS FOR CLARITY FOR A SPECIFIC LOCATION REQUIREMENT AND SHALL NOT BE INTERPRETED AS EXTENT OF THE REQUIREMENTS FOR THESE ITEMS. City of u la U SS OTHERWISE SHOWN, LOCATE ALL ROOM THERMOSTATS 4'-0" (CENTERLINE) ABOVE FINISHED FLOOR. NOTIFY THE ENGINEER BUILDING ISIOFf 7. ALL ROOF PENETRATIONS SHALL BE MINIMUM OF 5 FEET AWAY FROM THE AREA/OCCUPATION SEPARATION WALLS. ALL PIPE, DUCT AND CONDUIT PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE FIRE AND SMOKE STOPPED PER CODE. 8. ALL EQUIPMENT, DAMPERS, PIPING, AND ACCESSORIES IN CONCEALED SPACES REQUIRING ACCESS SHALL HAVE ACCESS DOORS. ALL ACCESS DOORS IN FIRE RATED STRUCTURE SHALL BE ARE RATED. COORDINATE LOCATIONS WITH ARCHITECT. CONTRACTOR TO PROVIDE ACCESS DOORS. 9. ALL EQUIPMENT SHALL BE FREE FROM DEFECTS IN MATERIAL WORKMANSHIP, AND SHALL BE OF THE KIND AND QUALITY DESCRIBED HEREIN. 10. ALL EQUIPMENT SHALL BE APPROVED FOR INSTALLATION IN THE STATE OF WASHINGTON AND SHALL HAVE ALL CERTIFICATIONS AND RATINGS REQUIRED TO MEET ALL ENERGY, POLLUTION, ENVIRONMENTAL, SEISMIC, ETC. CODES AND REGULATIONS. 11. VERIFY ALL THE MECHANICAL EQUIPMENT'S ELECTRICAL LOADS VOLTAGE/PHASE, ETC. WITH ELECTRICAL CONTRACTOR PRIOR TO ORDERING. 12. WHERE MULTIPLE RISERS OR HORIZONTAL LOOPS ARE USED, BALANCING VALVES IN THE RETURN LINES ARE REQUIRED. A CHECK VALVE SHALL BE PROVIDED IN EACH RETURN TO PREVENT TEMPORARY REVERSAL OF FLOW. 13. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL COMPLETE AND OPERABLE MECHANICAL SYSTEMS AS INDICATED ON THE DRAWINGS, AS SPECIFIED AND AS REQUIRED BY IMC, UPC, IBC, WASHINGTON STATE ENERGY CODE AND ALL APPLICABLE LOCAL AMENDMENTS. 14. INSTALL ALL MECHANICAL EQUIPMENT AND APPURTENANCES IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS, CONTRACT DOCUMENTS, AND APPLICABLE CODES AND REGULATIONS. 15. COORDINATE CONSTRUCTION OF ALL MECHANICAL WORK WITH ARCHITECTURAL STRUCTURAL ELECTRICAL WORK, ETC., SHOWN ON CONTRACT DOCUMENT DRAWINGS. 16. ALL TESTS SHALL BE COMPLLILD BEFORE ANY MECHANICAL EQUIPMENT OR PIPING INSULATION IS APPLIED. 17. WHERE TWO OR MORE ITEMS OF THE SAME TYPE OF EQUIPMENT ARE REQUIRED, THE PRODUCT OF ONE MANUFACTURER SHALL BE USED. 18. LOCATIONS AND SIZES OF ALL FLOOR, WALL, AND ROOF OPENINGS SHALL BE COORDINATED WITH ALL OTHER TRADES INVOLVED. 19. REFER TO TYPICAL DETAILS FOR DUCTWORK, PIPING, AND EQUIPMENT INSTALLATION. 20. RECORD DRAWINGS SHALL BE PROVIDED TO THE OWNER WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE AS REQUIRED BY SECTION 1416.1 OF THE WSEC. THE DRAWINGS SHALL INDICATE THE LOCATION AND PERFORMANCE DATA OF EQUIPMENT, GENERAL CONFIGURATION OF DUCTWORK AND PIPING DISTRIBUTION SYSTEMS, INCLUDING FLOW RATES AS A MINIMUM, THAT HAVE BEEN DEVIATED FROM THESE DOCUMENTS. A COMPLETE RECORD OF CHANGES SHALL BE KEPT TO DATE ON A DAILY BASIS AND MADE ACCESSIBLE TO OWNER AND ENGINEER. 2012 WASHI\GTON STATE ENERGY CODE (WSEC) NOTES 1. HVAC EQUIPMENT SHALL HAVE MINIMUM PERFORMANCE AT SPECIFIED RATING CONDITIONS NOT LESS THAN THE VALUES INDICATED IN C403.2.3. 2. HVAC SYSTEMS SHALL BE EQUIPPED WITH AUTOMATIC CONTROLS CAPABLE OF ACCOMPLISHING SETBACK OR SHUTDOWN DURING UNOCCUPIED PERIODS AS REQUIRED BY SECTION C403.2.4.3.2 OF THE WSEC AND AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES, IF PROVIDED. 3. PROVIDE BALANCING DEVICES IN ALL BRANCH DUCTS AND PIPE RUNS TO TERMINAL DEVICES AS REQUIRED BY SECTION C403.2.7.3 OF THE WSEC AND AS INDICATED ON THE CONTRACT DOCUMENTS. 4. ALL DUCTWORK SHALL COMPLY WITH SMACNA STANDARDS FOR CONSTRUCTION OF GALVANIZED DUCTWORK. ALL DUCTWORK SHALL BE SEALED AS REQUIRED BY SECTION C403.2.7 "DUCT AND PLENUM...* OF THE WSEC. DUCT TAPE NOT ALLOWED. 5. ALL DUCTWORK SHALL BE INSULATED AS REQUIRED BY SECTION C403.2.7 OF THE WSEC. 6. MOTOR EFFICIENCY SHALL NOT BE LESS THAN THE MINIMUM CALLOUTS PER C403.3.1 AND SECTION C403.2.13 OF THE WSEC FOR FULL LOAD EFFICIENCIES. 7. HVAC SYSTEMS SHALL BE BALANCED AS REQUIRED BY SECTION THE WSEC. 8. IF NOT SPECIFICALLY STATED ABOVE, CONTRACTOR SHALL COMPLY WITH THE WSEC ITEMS THAT DO APPLY TO THIS PROJECT. rTi, PERMIT •:.'_}2 ED FOR: Electrical Plumbing 4, Gas Piping of Tukwila DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. ANY ROOMS WHERE THE ABOVE LOCATION CANNOT BE MAINTAINED OR WHERE THERE IS A QUESTION ON LOCATION. 7. ALL DUCTWORK SHALL CLEAR DOORS AND WINDOWS. 8. PROVIDE ALL 90 DEGREE SQUARE ELBOWS WITH DOUBLE RADIUS TURNING VANES UNLESS OTHERWISE INDICATED. PROVIDE ACCESS DOORS UPSTREAM OF ALL ELBOWS WITH TURNING VANES. 9. UNLESS OTHERWISE NOTED, ALL DUCTWORK IS OVERHEAD, TIGHT TO THE UNDERSIDE OF THE STRUCTURE (WITHIN TRUSSES), WITH SPACE FOR INSULATION IF REQUIRED. 10. MAXIMUM LENGTH OF FLEXIBLE DUCTS LOCATED ABOVE HARD CEILINGS SHALL BE AS CODE PERMITS BUT NO LONGER THAN 4 FEET. 11. ALL DUCTWORK SHALL BE COORDINATED WITH ALL TRADES INVOLVED. OFFSETS IN DUCTS, INCLUDING DIVIDED DUCTS AND TRANSITIONS AROUND OBSTRUCTIONS, SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER. 12. PROVIDE ACCESS DOORS IN DUCTWORK TO PROVIDE ACCESS FOR ALL VOLUME DAMPERS AND OTHER ITEMS LOCATED IN THE DUCTWORK WHICH REQUIRE SERVICE AND/OR INSPECTION. 13. ALL DUCTS SHALL BE GROUNDED ACROSS FLEXIBLE CONNECTIONS WITH FLEXIBLE COPPER GROUNDING STRAPS. GROUNDING STRAPS SHALL BE BOLTED OR SOLDERED TO BOTH THE EQUIPMENT AND THE DUCT. 14. MAKE ACCEPTABLE ACCESS PROVISIONS FOR REMOVAL OF FILTER AND MAINTENANCE FOR ALL INDOOR UNITS. 15. ALL AIR DISTRIBUTION SUPPLY OUTLETS AND RETURN/EXHAUST INLETS SHALL HAVE VOLUME CONTROL DEVICES. 16. ALL 90 DEGREE TRUNK DUCT ELBOWS SHALL BE SMOOTH -ROUND OR SQUARE WITH TURNING VANES. 17. CONTRACTOR SHALL LOCATE AND COORDINATE EXACT LOCATION OF DUCTWORK WITHIN THE STRUCTURE AT SITE. 18. ALL FAN SYSTEMS WITH OVER 2000 CFM SHALL HAVE SMOKE/DUCT DETECTORS TO SHUT -DOWN FAN UPON DETECTION. DUCT/SMOKE DETECTORS FURNISHED AND INSTALLED BY ELECTRICAL AND WIRED BY ELECTRICAL DUCT/SMOKE DETECTORS SHALL BE LISTED BY AN APPROVED AGENCY AND FOR INSTALLATION IN AIR DUCTS PER IMC. 19. ALL MECHANICAL HEATING AND VENTILATION EQUIPMENT SHALL. CONFORM TO SMACNA, LOCAL AND STATE REGULATIONS FOR SEISMIC RESTRAINT (INCLUDING PIPING AND DUCTWORK). COORDINATE WITH STRUCTURAL 20. ALL RECTANGULAR DUCTWORK SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS. SUPPLY AND RETURN DUCTWORK FOR HVAC TO HAVE 1" SOUNDLINING FOR THE FIRST 10 FEET FROM UNIT DISCHARGE OUTLET. ALL DUCT UNING TO MEET AND EXCEED MOLD, HUMIDITY, EROSION RESISTANT, ETC. TO MEET 1MC CHAPTER 6. ALL DUCTWORK TO BE CL''ji"I� ., LASS -II DUCTS SHALL NOT BE USED. SITE INFO ADDRESS: 14240 INTERURBAN AVE S TUKWILA, WA 98168 OWNER: PARCEL/TAX # LEGAL: GAS PACKAGED ROOFTOP T EQUI ENT SCHEDULE MARK LOCATION UNIT COOLING GAS FEAT SOLAR, ELECTRIC OPERATING BASIS OF DESIGN SERVES REVIARKS NOMINAL TONS TOTAL CFM OSA CFM BON CYCLE SP HP/BIP TOTAL (BTUs -I) SENSIBLE (BTLII•I) EER INPUT (MBH) tEATI l+G (MBH) TBUP RISE CFM DBA (DB) VOLTAGBPH,4SE MCA NIDCP {} WEIGHT: Lbs M+ANLFACTIRBR MODE,. B-4 ROOF 10 4000 400 100% 0.5 /293 119,850 92,510 12 120/183 148 34.3 4000 87 460V / 3PH 27 30 1298 CARRIER 48HCC011 BB2A6-6UI1-10 NEW UNIT ENTRY, CORE AREAS CF STEs 224, 230, 244, 248 B-6 ROOF 15 6000 600 100% 0.5 /3.10 119,850 92,510 12 176/223 178 27.5 _ 0300 84 460V / 3PH _ 426 50 2303 CARRIER 48HC OD17B2A6-6DI1-E) NEW UMT PERIMI i ti-tS CF STEs 230, 244, 248 Permit o. MtL-OW1 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Co„ s is a y� >� edged: By: Date: 3365901881 City of Tukwila BUILDING DIVISION HILLMANS SEATTLE GARDEN IRS POR OF LOT 1 & ALL OF LOTS 2 THRU 7 & POR ADJ IN SE 1/4 OF SECTION 14-23-04 DAF - BEG SE COR OF SAID LOT 7 TH NLY ALG ELY LN 315 FT TO LFT BANK OF DUWAMISH RIVER AS ORIGINALLY PLATTED TH CONTG ON NLY PROD OF SD ELY 220 FT M/L TO LFT BANK AS EXISTED UNDER SUPERIOR COURT CAUSE NO 81-2-05910-4 TH WLY ALG SD BANK TO AN INTSN WITH NELY PROD OF SELY LN OF NWLY 72 FT OF SD LOT 1 TH SWLY ALG SD LN PROD 200 FT M/L TO LFT BANK OF DUWAMISH RIVER AS PLATTED IN ORIGINAL PLAT TH CONTG IN SWLY DIRECTION ALG SELY LN OF NWLY 72 FT OF SD LOT 1 DISTANCE OF 55 FT M/L TO SWLY LN OF SD LOT 1 TH SELY ALG SD LN TO INTSN WITH N MGN OF S 143RD ST FIRST AVE TH ELY ALG SD MGN TO TPOB-TGW POR FOSTER JOSEPH DC #39 BEING POR OF ABANDONED PUGET SOUND ELECTRIC RR R/W IN THE SW 1/4 OF SE 1/4 OF SD SEC 14 SD RR R/W BOUNDED ON NE BY MAULE AVE ON SW BY A LN 20 FT NE OF & PLT NELY MGN OF SR 181 UNDER REC #8905231113 ON THE SE BY R/W #5 & ON THE NW BY R/W #6 BOTH R/W DEFINED IN QCD AUD FILE # 6557639 - TGW VAC MAULE AVE ADJ TGW POR VAC ST ADJ BELLTOWN INVESTMENT PARTNER :t- • • A Service Logic Company 3132 N.E. 133 ST Seattle, Washington 98125-4423 PO Box 27073 Seattle, Washington 98165-1473 (206) 367-2500 Fax (206) 368-6856 PSRHVMS924JT o c0 Z co V roW <C or z �C V) W W LL' = W 00 .1� W1 • c O W 0 TUKWILA, WA, 98168 1 I COPYRIGHT NOTICE THIS LAYOUT/DESIGN ISAN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. RECEIVED CITY OF TUKWILA JUN 102014 PERMIT CENTER PERMIT SET 6-10-14 Revision/Issue Date, Dr :. By A. BONILLA 610-14 Lead Tech Engineered By Date rP4909 sheet 1 Project Manager N. SINGER M 0.0 Scale `VARIES _ 4, KEY PLA SCALE NOTE: AREA OF WORK • • • • • • • • • SITE MAP / ,/ • • • • / • • • • ,/ • • • • 1 "=30'-0" • • • • i 1 i i REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 7 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 1 0 2014 PERMIT CENTER 3132 N.E. 133 ST Seattle, Washington 98125-4423 PO Box 27073 Seattle, Washington 98165-1473 (206) 367-2500 Fax(206)368-6856 PSRHVMS924JT I TUKWILA, WA 98168 COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. J r 1 1 PERMIT SET 6-10-14 `No. Revision/Issue Date, brawn By A. BONILLA Date 6-10-14 Lead Tech Engineered By Date N Project Sheet P4909 Project Manager N. SINGER M 0.1 Scale AS NOTED <EY PLAN SCALE NOTE: AREA OF WORK DEMO PLAN REVIEWED FOR CODE COMPLIANCE CE AP JUN 27 2014 City of Tukwila BUILDING DIVISION Unit 18-2 Unit 03-7 0 • 20'-0" Unit-6 Unit 03-3 Unit #B-4 39'-0" nr_l_k_iit B-1 28'-2" Unit jB-5 rir______ 40'-2" M(LkOI(ff RECEIVED CITY OF TUKWILA JUN .1.02014 PERMIT CENTER • A Service Logic Company t 3132 N.E. 133 ST Seattle, Washington 98125-4423 PO Box 27073 Seattle, Washington 98165-1473 (206) 367-2500 Fax (206) 368-6856 PSRHVMS924JT TUKWILA, WA 98168 J COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. 1 1 PERMIT SET 6-10-14 No. Revision/Issue Date, Drawn By A.BONILLA G--10-14 Lead Tech Engineered By Date Project P4909 Sheet 447* Project Manager N. SINGER M 1 •0 Scale `AS NOTED J 1 /16"=1' i �ii nue�r�s <EY PLAN SCALE NOTE: AREA OF WORK 'iuODeeti w ms 0 0 ❑ ❑ HVAC PLAN 1 /16"=1' Unit #8-2 rii- Unit l8-7 51'-0" 5'-0" ■ Unit-4 REVIEWED FOR CODE COMPLIANCE APPROVED SUN 21 2014 City of Tukwila BUILDING DIVISION 20'-0" Unit 18-3 39'-0" Unit #B-9 6'-0" Unit —1 28'-2" Unit —5 40'-2" M 1-k0117 RECEIVED CITY OF TUKWILA JUN 1 0 2014 PERMIT CENTER 3132 N.E. 133 ST Seattle, Washington 98125-4423 PO Box 27073 Seattle, Washington 98165-1473 (206) 367-2500 Fax (206) 368-6856 PSRHVMS924JT i 0_ D m fly 0 0 w m Z w m (/)zce U 'J# W LL 1- TUKWILA, WA 98168 COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. 1 PERMIT SET 6-10-14 �No. Revision/Issue Date! raven By A. BONILLA G--10-14 Lead Tech Engineered By Date Project Sheet P4909 Project Manager N. SINGER M 2.0 scale AS NOTED B-6 B-4 EXISTING 3'-6" PARAPET --- I I ri1 )( 7'-4" EXISTING ROOF JP 39'-0"ir / EXISTING 3'-6" PARAPET / 15'-3" pt Ih J I ( bI CO N 1 in r 4. _ ___1—L EXISTING ROOF 1,-.. N N (NIco t 1 BUILDING A NOTH ELEVATION 1/16" = 1'-0" EXISTING 3'-6" PARAPET B-6 I I_ I EXISTING ROOF 1 / EXISTING 3'-6" PARAPET ' o 4. co I I " t 24'-2" 57'-5" / I I \-N EXISTING ROOF jc I co in O I co%I. 1 BUILDING A EAST ELEVATION 1/16" = 1'-0" 4'-10" ---f- EXISTING 3'-6" PARAPET I I I I 1 L 1 EXISTING ROOF 1 7'-2" n _L L EXISTING GRADE — 15'-6" f 50'-8" / BUILDING A SOUTH ELEVATION 1/16" = 1'-0" 1 L 1 B-6 B-4 II u 1 r- EXISTING 3'-6" PARAPET EXISTING ROOF r--1--I I I L 1 1 EXISTING 3'-6" PARAPET 24'-0" 57'-5" r7--� EXISTING 3'-6" PARAPET EXISTING ROOF EXISTING ROOF BUILDING A WEST ELEVATION REVIEWED FOR CODE COMPLIANCE APPROVED JUG 2 7 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN102014 PERMIT CENTER • A Service Logic Company 3132 N.E. 133 ST Seattle, Washington 98125-4423 PO Box 27073 Seattle, Washington 98165-1473 (206) 367-2500 Fax (206) 368-6856 PSRHVMS924JT 0 D 0 oc CO U I — COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. J r 1 1 PERMIT SET 8-10-14 l No. Revision/Issue Date, Drawn By A. BONILLA G-10-14 Lead Tech Engineered By Date 1/16" = 1'-0" Project P4909 Sheet Project Manager N. SINGER 1 M 3.0 Scale AS NOTED