HomeMy WebLinkAboutPermit M14-0120 - FAIRWAY CENTER - BUILDING A - ROOFTOP GAS HEATING AND AIR CONDITIONING UNITSFAIRWAY CENTER BUILDING A 14220 INTERURBAN AVE S M14-0120 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 , Inspection Request Line: 206-438-9350 Web site: httD://www.TukwilaWA.eov MECHANICAL PERMIT Parcel No: 3365901881 Permit Number: M14-0120 Address: 14220 INTERURBAN AVE S Issue Date: 7/2/2014 Permit Expires On: 12/29/2014 Project Name: FAIRWAY CENTER - BUILDING A Owner: Name: BELLTOWN INVESTMENT PARTNER Address: 2505 2ND AVE #520 , SEATTLE, WA, 98121 Contact Person: Name: ADRIANA BONILLA Phone: (206) 367-2500 Address: 3132 NE 133 ST, SEATTLE, WA, 98125 Contractor: Name: PSR-HVAC & MECHANICAL SERVICES Phone: (206) 367-2500 Address: PO BOX 27073 , SEATTLE, WA, 98165 License No: PSRHVMS924JT Expiration Date: 4/30/2016 lender: Name: Address: , , , DESCRIPTION OF WORK: REPLACE (1) ROOFTOP GAS HEATING/ELECTRIC AIR CONDITIONING PACKAGE UNIT Valuation of Work: $10,766.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $337.36 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 Permit Center Authorized Signature: 111-)-A--- 2012 2012 2012 Date: -7 _.)---- ! LI I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or th performance of work. I am authorized to sign and obtain this development permi d agree tarh" co s attached to this permit. Signature: Print Name: PA I fY1aLr yaeC.,k$ Date: /7—/2..49/ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 19: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 14: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 17: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 13: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 18: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 11: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 21: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: (`•t O ^ I L Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** King Co Assessor's Tax No.: 3365901881 Site Address: 14220 Interurban Avenue South Suite Number: Floor: Roof Tenant Name: Fairway Center, Buildings A New Tenant: ❑ Yes m..No PROPERTY OWNER Name: BELLTOWN INVESTMENT PARTNER Address: 14220 INTERURBAN AVE S 98168 City: Tukwila State: WA Zip: 98188 CONTACT PERSON - person receiving all project communication Name: Adriana Bonilla Address: 3132 NE 133rd Street City: Seattle state: WA Zip: 98125 Phone: (206) 367-2500 Fax: (206) 368-6856 Email: adriana.bonilla@psrmechanical.com MECHANICAL CONTRACTOR INFORMATION Company Name: PSR Mechanical Address: 3132 NE 133rd Street City: Seattle State: WA Zip: 98125 Phone: (206) 367-2500 Fax: (206) 368-6856 Contr Reg No.: PSRHVMS924JT Exp Date: 04/30/2014 Tukwila Business License No.: 602811195 Valuation of project (contractor's bid price): $ 10,766 Describe the scope of work in detail: Replace 1 RTU gas heating/electric air conditioning package unit Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric Gas m Other: H:\Applications\Forms-Applications On Line\201 I Applications\Mechanical Permit Application Revised 8-9-I I.docx Revised: August 201 I bh Page 1 of 2 r • Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfiu Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AU )4HO Signature: GENT: Date: 06/09/2014 Print Name: Adriana Bonilla Day Telephone: (206) 367-2500 Mailing Address: 3132 NE 133rd Street H:\Applications\Forms-Applications On Line\201 I Applications\Mechanical Permit Application Revised 8-9-1I.docx Revised: August 2011 bh Seattle WA 98125 City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT PermitTRAK QUANTITY I PAID $337.36 M14-0120 Address: 14220 INTERURBAN AVE S Apn: 3365901881 $337.36 MECHANICAL $324.38 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $227.00 PLAN CHECK FEE R000.322.102.00.00 0.00 $64.88 TECHNOLOGY FEE $12.98 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2319 R000.322.900.04.00 0.00 $12.98 $337.36 Date Paid: Tuesday, June 10, 2014 Paid By: PSR MECHANICAL Pay Method: CHECK 013016 Printed: Tuesday, June 10, 2014 11:11 AM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 61 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Type of Inspection: Special Instructions: Date Wanted: Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION . 11 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 INSPECTION RECORD Retain a copy with permit Project: , Type of Inspection: Address: Special 'Instructions: ElApproved per applicable codes. rrections required prior to approval. COMMENTS: A Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Type of iinsspecttioonn: - /^' j `! A-)/ Address: ( Date Called: Special Instructions: Date Wanted Requester: Phone No ElApproved per applicable codes. 12 ections required prior to approval. COMMENTS: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Bi lling Address INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER /IA ,l -1- TX, PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 446, Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: of/di 0,(44r- Type of nspe tion: Suite #: 4-A--1 Contact Person: Special Instructions: Phone No.: %.,,Approved per applicable codes. Corrections required prior to approval. COMMENTS: /1 ii7-e cf ey 710 AI/ Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: , Inspector: /3 3 Date: j0/2_0 y Hrs.: % b $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Depaytme t. Call to schedule a reinspection. `I( Attn: Company Name: Address:,7Q3 0 ,4/7 .P' i2 7 W f- City: S Q44 7T' A ,4'%A72- rvc `(State: t4J Zip: Word/Inspection Record FormDoc 6/11/10 T.F.D. Form F.P. 113 CWA CONSULTANTS, P.S. STRUCTURAL ENGINEERING BUILDING CODE CONSULTANTS PILE COPY REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 7 2014 8675 E. Caraway Road, Port Orchard, WA 98366 (360) 871-5433 FAX: (360) 871-5633 E Mail: chuck r)cwaoon. June 9, 2014 HVAC Roof Attachment l'SR HVAC and Mechanical Services Fairway Center Unit A4 Seattle, WA Fp=_(0_.4apxSDs)(1+2z/h) Wp Rp/Ip ASCE 7 Table 13.6-1 ap=2.5, Rp=6.0 SPs = 0.846 z/h = 1.0 max Connect new metal curb of HVAC unit to existing wood framing #12 screws (4 min) @ 24" oc at perimeter Connect HVAC unit to curb per manufacturer's installation instruction Fp = (0.4x2.5x0.846x3.0) Wp = 0.423 Wp 6.0/1.0 Fp max =1.6x0.846 =1.35 Fp min = 0.3x0.846 = 0.25 Use 0.423 `stity of Tukwila BUILDING DIVISION Fp@CG— ¢ Wp 4x6 at curb support with 5A48 top flange hanger each end (Existing) Existing 16" TJI Type Roof Joists Existing 8-3/4"x36" GIu-Lam Carrier 48HCED08B2A6-0B0130 HVAC Unit — Wt =1119# + 110# =1229# total including curb L=88" W = 60" H = 49" Cg = 22" +14" curb = 36" above base Fp = 0.423x1229 = 520# Wind X = .85x1.3x(4.0x6.5)(13) = 373# Wind Y = .85x1.3x(4.0x4.0)(13) =172# USE 520# for all talcs cet OT (worst case) = 520x36 — 0.6x1229 x (60-34) _ -452"# no net overturning RECEIVED CITY OF TUKWILA Attachment HVAC Unit connection to existing wood framing- #12 Wood screws Cap = (130x1.6)# x 4 (min) = 832# min > 520# OK Max Corner Weight = 278# (4x6 span 4' OK) JUN 102014 PERMIT CENTER MI3oI2o R:\Documents\Word Fiies\PSR\PSR Fairway Center HVAC Installation A4.doc Performance Summary For A4 Project:—Untitled2 Prepared By: 05/09/2014 07:24PM Part Number:48HCED08B2A6.0B0B0 ARI EER• _ 12.00 IEER 13.0 Base Unit Dimensions Unit Length. 88.1 in Unit Width. 59.5 in Unit Height 49.4 in Operating Weight Base Unit Weight . 925 Ib Medium Heat 15 Ib RA Smoke Detector_ 5 lb Medium Static Option - Belt Drive. 15 Ib Temperature Economizer w/ Barometric Relief. 74 Ib HACR Breaker:___. 10 Ib Accessories Power Exhaust System' Total Operating Weight Unit Unit Voltage -Phase -Hertz. _460-3-60 Air Discharge' Vertical Fan Drive Type* Belt Actual Airflow. 3000 CFM Site Altitude:. 0 ft Cooling Performance Condenser Entering Air DB• 95.0 F Evaporator Entering Air DB• 80.0 F Evaporator Entering Air WB• 67.0 F Entering Air Enthalpy 31.44 BTU/Ib Evaporator Leaving Air DB• 57.7 F Evaporator Leaving Air WB• 57.2 F Evaporator Leaving Air Enthalpy• 24.53 BTU/Ib Gross Cooling Capacity 93.30 MBH Gross Sensible Capacity 72.19 MBH Compressor Power Input. 6.24 kW Coil Bypass Factor 0.198 Heating Performance Heating Airflow. 3000 CFM Entering Air Temp:.. 70.0 F Leaving Air Temp. 115.7 F Gas Input Capacity. 120.01180.0 MBH Gas Heating Capacity' 148.00 MBH Temperature Rise- 45.7 F NOTE- Second Stage Supply Fan External Static Pressure. 1.00 in wg Options / Accessories Static Pressure EconoMi$erlV / EconoMi$er2• 0.11 in wg Power Exhaust' (Fan Data Includes Drop) Total External Static* 1.11 in wg Fan RPM. 913. Fan Power _ 1.69 BHP NOTE Selected IFM RPM Range: 690 - 936 Power Exhaust Packaged Rooftop Builder 1.39i Page 7 of 32 Certified Drawing for A4 Project: -Untitled2 Prepared By: 05/09/2014 07:24PM NOTES: is 5 11 9 91EA04 14ILCIVFTEGSOINEN310N5 2. CENTER OF GRAVITY 3. 1.10, DIRECTI04 OF AIR FLOW UNIT J ) N H 48RC-A01 41 114 ((0481 33 3(4 1A571 (S 1/9 1491E 46HC•D9 49 3/8 [12531, 34 3/8 18233 15 7/8 1403E 48�'1[ 123118 9ra 2 (403 8 FILTER ACCESS PANEL I T001-LESS1 INDOOR COIL. ACCESS PANEL CONDENSER COIL BACK 3.374 lf51 59 1/2 (15107 / I LSE' OPTIONAL FACTORY INSTALLED CONVENIENCE OUTLET Packaged Rooftop Builder 1.391 LEFT 4-5/8 0181 1 1:1151 (1121 11557 111 1 j (2781 ECTRICAL DISC0N9EC1 LOCATION 27.7/9 l7 9I 7-5/ (671 T7P CURB VIDE 1 29 5/8 (7511 E ALT. CONDENSATE AIN OPEM]NO 1h11'4 IN SASEPAN V [�— ID 3/8 110211 URETER P.o. eo1 am TECH10E061ES 4140D1t, 11 CARRIER t0721 111Ii1 >(lY(1tt(11C ACNPT1t 8110E [MDifi10 9N11T114 108?EIIF Fill TOT 11 D(Nt10fTD 0R 0110 YIfNOtt.CAM'[[ <OIIOIA1104Y FA1hCF CO'fFXi. 514F1111C1 01 7A[11 F475879P1s1 04 f011RR4 D0F3 0? 00111/1m51 �411]IYIIK04 4NC0 0R ECONDNIIER H000 IOPTI0NAL1 ti8 EE THRU THE BASE CHART 36-3/0 (9251 RETURN AIR 20-3/4 (731I SUPPLY Alt 20-3.4 (3211 12-5/9 [3211 31-316 40-3/8 1953E [1 211 cm, \--FLUE HOOD TOP 3.1/4 —" 14 .�..- 183E (3581 2S 1/2 —6, 0140 8 CONTROL BOX ACCESS PANEL OPTIONAL T0CNAL FACIORY INSTALLED •DISCONNECT F NANDLE�.b N• • t•�5�m — iii 0-3/8 INDOOR BLOWER ACCESS : �NANOLE • C/7/ • _ 2 N 37 12141 8910E 09-1/8 [2t301 FRONT 4011 RETURN AIR SUPPLE AIR (321 13-7/8 I3 30 5-3/4 I1461 6-1/4 (140) (1591 CONNECTION SIZES A 1 3/8. 1)51 DIA FIELD POWER SUPPLY ROLE 8 t 1/2' 1141 01A POKER SUPPLY KNOCKOUT C 1 3/4' (511 0(A GAUGE ACCESS PLUG D 1/S' (227 D[A FIELD CONTROL WIRING ROLE E 3/4'-I4 KEPT C09DENSATE DRAIN 1/2--14 8PT DA3 CONNECTION 3/4'-74 KEPT GAS CONNECTION 0 2 ' 131E REA POWER SUPPLY RHCC4-OUT THRU THE -BASE CHART (FIELD INST) THESE HOLES REQUIRED FOR USE 91TH AM BITS: C981700001A01: 01 - GAS THRU CURB CRBTNF9R102A01: 08,09 - 6AAS TRIM CRAB C191NF9A003A01: 01 - GAS TIIRU MOAN CIBTVP 11004A01: 08,09 - GAS TR1U BASEPAN THREADED HIRE. REO'D ROLE CONDUIT 312E USE STIES (MIA V 1/2' ACC, 7/0' 122.21 T 1/2' 24V 7/8' [22.21 3/4' (001,0031 1 1/8' 128.51 T 1 1/4' (002.D041 POWER 1 311' (44.41 (0031 1/2' FPT 1 1/8' (28.61 (0041 3/00/1 OAS 1 311' 144.41 - Y (001 1 002) PROV10 FLAKE 1 FITTING. 9 3/4' FIT TRRU C098 4)0.E SITE: 2' 130.8E THRU-THE-BASE CHART (FIOPI FOR •T4RU-I11E-BASEPAN' FACTORY-0PT101, FITTINGS FOR ONLY X, T, 1 2 ARE PROVIDED. I' IFOR BELOW LISTED ROOFER. A FIE1O 1 UPPIIED 1/2' ADAPTER IS REOVIREO i4 SEMEN BASE PAN FITTING AND OAS VALVE( 9NCO,E,S,1-01 0(00,5-08 40HCO,G-09 12•518 I)211 E BYO.. CONDENSATE DAMN +--- 28-I/8 MN) SUPPLY AIR ' RETURN. N AR • 37 7/8 1942E SUPPLY AIR 11771 5-41 1148E 41 7/B E10051 Aik RIGHT RETURN AIR LEER t 4.519 (1131 BAAONE7RIC RELIEF FLOW SKEET 10F2. 41t 10-05-10 annuls 10-16-09 48HC 07-09 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48T11502708 A Page 5 of 32 Certified Drawing for A4 Project:-Untitled2 Prepared By: 05/09/2014 07:24PM OMIT STD. UNIT RE(6N( 9 COINER WEIGHT SA1 CORNER WEIGHT (87 C0RNE1 9EI6NT ICI CORNER MOAT (D1 C.O. LDS. AG. LN1. KG. OS. AG. LISS', E6. US. KG. A T 2 1186-407 765 341 165.3 15 152.7 i9.3 214.7 91,4 232.3 105.4 42 5/8 510141 34 314 (882.61 19 718 15051 48)00-008 025 410.5 204.1 /2.4 190.0 06.6 251.1 116.2 2/3.9 124.2 42 5/8 E14421 34 1/4 (8671 22 1/0 75816 42864104 525 419.2 204.1 42.6 100.0 98.0 256.1 116.2 273.9 124.2 02 5/3 (10621 34 110 11271 22 118 (5911 CORNER A 6- `r-1 o { } l IJ 100 i 1 1 : 00 0 UNITE4 9.8, 101 4103 TECHNOLOGIES 14n90Q, 91 1:0119T50188919 0 a 04I1*91 97 a C/u001 79 t4i111[ 4N960 1(09l 1 NNIno 1 1, a SYE4 Ni79air 9A9aa 1994199104 99 I1111 MA4(469 M1 00RRR9 e0E1 491 1419016 9A41 41410AY44N 08 397A9a_0( 044(1417. SIA90ARD SNIT WEIGHT IS WITH LOW OAS HEAT AND WITHOUT PACKAGIRO, FOR OTHER OPTIONS Alp ACCESSORIES. REFER TO TIE PRODUCT DATA CATALOG. CORNER B 4RE7 20F2 Ulf 10-05-10 410218260 10-16-09 488C 08-12 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48114502708 A Packaged Rooftop Builder 1.391 Page 6 of 32 d YI i S2130YVH f /M 11V3 0312f0ddOddnS 'O0 ,8b ft (rl) !slot` ssnat ,9l b-vi i!unr d.l 'SYVV38 WV1-n10 1NOddfS 01 13)IO0d FW38 MA NWn103 1331S -xoaaav o ,9- jA1 'WV38 WV1-010 ,b/£-9x,6£ 2130 H ® 031 180ddn isior HlIM rl ddOS ONIIW U 8n3 fHV 9xb —11 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0120 DATE: 06/10/14 PROJECT NAME: FAIRWAY CENTER - BUILDING A SITE ADDRESS: 14220 INTERURBAN AVE S X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division II Public Works AV imm009 Fire Prevention me rk 01o1-Li•(LA Structural Planning Division Permit Coordinator 1111 PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 06/12/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 07/10/14 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PSR-HVAC & MECHANICAL SERVICES Page 1 of 2 Washington State Department of ' Labor & Industries PSR-HVAC & MECHANICAL SERVICES Owner or tradesperson O'MALLEY, JAMES J Principals O'MALLEY, JAMES J, MEMBER HOGERTY, REAGAN P, MEMBER BAVINS, NEIL JONATHAN, MEMBER O'DONNELL, STEPHEN 0 (End: 04/12/2012) RIST, STEVEN L (End: 04/12/2012) Doing business as PSR-HVAC & MECHANICAL SERVICES WA UBI No. 602 811 195 PO BOX 27073 SEATTLE, WA 98165 206-367-2500 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. PSRHVMS924JT Effective — expiration 04/30/2008— 04/30/2016 Bond International Fidelity Ins Co Bond account no. 0649932 $12,000.00 Received by L&I Effective date 03/28/2014 03/26/2014 Expiration date Until Canceled Insurance Zurich American Ins Co $1,000,000.00 Policy no. GL0488649704 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602811195&LIC=PSRHVMS924JT&SAW= 07/02/2014 LEGEND ABBREVIATIONS RISE CUBIC FEET PER MINUTE CENTER LINE ROUND DUCT INDICATOR OVAL DUCT INDICATOR THERMOSTAT LINE DIRECTION OF RISE FOR DUCT DUCT (FIRST FIGURE DENOTES VIEW SHOWN) SINGLE LINE DUCTWORK INDICATES DUCT WITH VIEW DIMENSION LESS THAN 12 INCHES SUPPLY OR EXHAUST TAKEOFF SUPPLY DUCT TURNING TOWARD, UP SUPPLY DUCT TURNING AWAY EXHAUST DUCT TURNING TOWARD, UP EXHAUST DUCT TURNING AWAY ROUND DUCT TURNING TOWARD, UP ROUND DUCT TURNING AWAY OVAL DUCT TURNING TOWARD, UP OVAL DUCT TURNING AWAY CONICAL WYE CONICAL TEE VOLUME DAMPER(VD) FIRE SMOKE DAMPER(FSD) MOTORIZED DAMPER(FD) FIRE DAMPER(FD) 3-WAY SUPPLY DIFFUSER 2-WAY SUPPLY DIFFUSER 2-WAY CORNER SUPPLY DIFFUSER 1-WAY SUPPLY DIFFUSER DOUBLE LINE, LINED DUCT/ ACOUSTIC DUCT RECTANGLE TO RECTANGLE FITTING (RIGHT) RECTANGLE TO RECTANGLE FITTING (LEFT) ROUND TO ROUND HIGH/ MEDIUM VELOCITY FITTING ROUND TO ROUND FITTING TO SUPPLY DIFFUSERS(DOUBLEULINED CT TAKE -OFF, LOW VELOCITY (PRESSURE) ROUND QUCT TAKE -OFF, TO SUPPLY DIFFUSER (SINGLE LINED) RECTANGLE/ ROUND RADIUSED ELBOW DUCT RECTANGULAR 90' ELBOW W/ TURNING VANES TYPICAL ECCENTRIC CONICAL DUCT REDUCTION FITTING CONCENTRIC CONICAL DUCT REDUCTION FITTING RECTANGLE TO ROUND FITTING SOUND ATTENUATOR TURNING VANES FLEXIBLE DUCT THERMOSTAT OR TEMPERATURE SENSOR THERMOSTAT OR TEMPERATURE SENSOR(CEILING) DUCT SMOKE DETECTOR SQUARE SUPPLY AIR DIFFUSER ROUND SUPPLY AIR DIFFUSER 2'x2' RETURN AIR GRILLE 2'x4' RETURN AIR GRILLE SIDEWALL SUPPLY AIR GRILLE OR REGISTER SIDEWALL RETURN/EXHAUST AIR GRILLE OR REGISTER AC ACF ADA ADJ AFF AL ALIGN AP APPROX ARCH ASME AVG BFF BHP BLDG BOD BOP BTU BTUH BV CD CFM CG CI CLG CO CONN CONST CON T COORD CORR COTG CU FT CU IN DB DCVA DEG DET DIA DIFF DIM DISCH DN DR DS DSD DWG EA EAT EF EFF EG ELECT ELEV EMERG ENT ESP EXH EXIST EXP FC FCO FD FDC FI O FLA FLEX FLR FOB FOI C FOT FPM FPS FSD FT FU G GA GAL GALV GEN GND GPH GPM H HP HR HTG HVAC HZ IBC ID IE IMC IN INSUL IW AIR CONDITIONING AIR CURTAIN FAN AMERICAN DISABILITIES ACT ADJACENT; ADJUST; ADJUSTABLE; ADJUSTMENT ABOVE FINISHED FLOOR ACOUSTIC LINED ALIGNMENT ACCESS PANEL APPROXIMATELY ARCHITECTURAL AMERICAN SOCIETY OF MECHANICAL ENGINEERS AVERAGE BELOW FINISH FLOOR BRAKE HORSEPOWER BUILDING BOTTOM OF DUCT BOTTOM OF PIPE BRITISH THERMAL UNIT BRITISH THERMAL UNITS PER HOUR BALANCING VALVE CEILING DIFFUSER CUBIC FEET PER MINUTE CEILING GRILLE CAST IRON CEILING CLEANOUT CONNECT; CONNECTED; CONNECTION CONSTRUCTION CONTINUOUS; CONTINUATION COORDINATE CORRIDOR CLEANOUT TO GRADE CUBIC FEET CUBIC INCHES DRY BULB TEMPERATURE DOUBLE CHECK VALVE ASSEMBLY DEGREE DETAIL DIAMETER DIFFERENTIAL DIMENSION DISCHARGE DOWN DRAIN DOWNSPOUT DUCT SMOKE DETECTOR DRAWING EACH ENTERING AIR TEMPERATURE EXHAUST FAN EFFICIENCY EXHAUST GRILLE ELECTRI CAL ELEVATION EMERGENCY ENTERING EXTERNAL STATIC PRESSURE EXHAUST EXISTING EXPANSION FAHRENHEIT FANCOIL FLOOR CLEANOUT FIRE DAMPER FIRE DEPARTMENT CONNECTION FURNISHED AND INSTALLED BY OWNER FULL LOAD AMP FLEXIBLE FLOOR FLAT ON BOTTOM FURNISHED BY OWNER INSTALLED BY CONTRACTOR FLAT ON TOP FEET PER MINUTE FEET PER SECOND FIRE SMOKE DAMPER FOOT, FEET FIXTURE UNITS GAS GAGE GALLON GALVANIZED GENERAL GROUND GALLONS PER HOUR GALLONS PER MINUTE HEIGHT, HIGH HORSEPOWER HOUR HEATING HEATING, VE NTILATING, AND AIR HERTZ INTERNATIONAL BUILDING CODE INDIRECT DRAIN INVERT ELEVATION INTERNATIONAL MECHANICAL CODE INCH INSULATE; INSULATION INDIRECT WASTE KW KWH L LAV LAT LB LF LVG MA MAX MBH, MBTU MCA M CC MD MECH MFR MIN MISC MOD MTD MTG NC NIC N TS OAC OAT OD OH ORD OA P PD PH POC PRELIM PRESS PRV PSI PSIG RA RD RECIRC RECT REF REG REQD RND RPBP RPM RV SCHED SF SG SO SOV SP SPEC SPECD SST SS STRUCT SWG SWR TBD TEM P TSTAT THRU TOD TOP TP TS TV TYP UPC U TR VD VEL VERT VOL VTR W WCO WB WEF WG W/ w/o WT KILOWATT KILOWATT HOUR LENGTH LAVATORY LEAVING AIR TEMPERATURE POUNDS LINEAL FOOT LEAVING MIXED AIR MAXIMUM THOUSAND BRITISH THERMAL UNITS PER HOUR MINIMUM CIRCUIT AMPACITY MOTOR CONTROL CENTER MOTORIZED DAMPER MECHANICAL MANUFACTURER MINIMUM; MINUTE MISCELLANEOUS MOTOR OPERATED DAMPER MOUNTED MOUNTING NOISE CRITERIA NOT IN CONTRACT NOT TO SCALE OUTDOOR AIR CONDITIONER OUTSIDE AIR TEMP OUTSIDE DIAMETER; OVERALL DIAMETER OVERHEAD OVERFLOW ROOF DRAIN OUTSIDE AIR PUMP PRESSURE DROP; PIT DRAIN PHASE POINT OF CONNECTION PRELIMINARY PRESSURE PRESSURE REDUCING VALVE POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAGE RETURN AIR ROOF DRAIN RECIRCULATING RECTANGULAR REFERENCE REGULATOR REQUIRED ROUND REDUCED PRESSURE BACKFLOW PREVENTER REVOLUTIONS PER MINUTE RELIEF VALVE DISCHARGE SCHEDULE SUPPLY FA, SQUARE FEET SUPPLY GRILLE SCREENED OPENING SHUT OFF VALVE STATIC PRESSURE SPECIFICATION SPECIFIED STAINLESS STEEL SOIL STACK, SANITARY SEWER STRUCTURAL SUPPLY WALL GRILLE SUPPLY WALL REGISTER TO BE DETERMINED TEMPERATURE; TEMPORARY THERMOSTAT THROUGH TOP OF DUCT TOP OF PIPE TRAP PRIMER TEMPERATURE SENSOR TURNING VANE TYPICAL UNIFORM PLUMBING CODE UP THRU ROOF VENT VOLUME DAMPER VELOCITY VERTICAL VOLUME VENT TO ROOF WASTE WALL CLEAN OUT WET BULB TEMPERATURE WALL EXHAUST FAN WATER GAGE WITH WITHOUT WEIGHT GENERAL NOTES: GENERAL HVAC NOTES: 1. COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM SHALL BE PER THE LATEST ADOPTED VERSION OF INTERNATIONAL BUILDING CODE (IBC), INTERNATIONAL MECHANICAL CODE (IMC), WASHINGTON STATE ENERGY CODE (WSEC), UNIFORM PLUMBING CODE (UPC), INTERNATIONAL FUEL GAS CODE (IFGC), INTERNATIONAL FIRE CODE (IFC), NFPA AND HEALTH CODES AND REGULATIONS AS ADOPTED BY THE LOCAL JURISDICTIONS. 2. CONTRACTOR SHALL COORDINATE DIFFUSER, GRILLE AND REGISTER LOCATIONS AND DUCT ROUTING CLEARANCES WITH THE STRUCTURAL REFLECTED CEILING AND LIGHTING PLANS. 1. CONTRACT DOCUMENT DRAWINGS FOR MECHANICAL WORK (HVAC) ARE DIAGRAMMATIC AND ARE INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY. 2. LOCATE ALL TEMPERATURE, DEVICES IN DUCTWORK LOCATIONS WITH STRAIGHT SEC11ON OF DUCT UP AND DOWNSTREAM AS RECOMMENDED BY THE MANUFACTURER FOR GOOD ACCURACY. .-.3, DINATE AND PROVIDE ALL DUCT TRANSITIONS REQUIRED FOR FINAL EQUIPMENT CONNECTIONS TO FURNISHED EQUIPMENT. REVIEWED FOR VERIFY AND COORDINATE ALL DUCT DIMENSIONS BEFORE FABRICATION. 3. MAKE ACCEPTABLE ACCESS PROVISIONS FOR REMOVAL OF FILTER AND MAINTENANCE FOR ALL INDOOR UNITS. REFER CODE COMPLIANCE MANUFACTURER'S INSTALLATION GUIDE. APPROVED AL EQUIPMENT, DUCTWORK, ETC., SHALL BE SUPPORTED AS REQUIRED TO PROVIDE A VIBRATION FREE INSTALLATION, AND 4. ALL CONTROL WIRE AND CONDUIT SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE. JUN 2 7 2014 OF SEI VIBRATION TOCBUILDING STRUCTUREED AS REQUIRED. OVIDE VIBRATION ISOLATION FOR ALL MECHANICAL EQUIPMENT TO PREVENT TRANSMISSION 5. WHEN MECHANICAL WORK (HVAC, PLUMBING, SHEET METAL, FIRE PROTECTION, ETC.) IS SUBCONTRACTED, IT SHALL B THE MECHANICAL CONTRACTOR'S RESPONSIBILITY TO COORDINATE SUBCONTRACTORS AND THE ASSOCIATED CONTRAC WHEN DISCREPANCIES ARISE PERTAINING TO WHICH CONTRACTOR PROVIDES A PARTICULAR ITEM OF THE MECHANICA CONTRACT OR WHICH CONTRACTOR PROVIDES FINAL CONNECTIONS FOR A PARTICULAR ITEM OF THE MECHANICAL CONTRACT, IT SHALL BE BROUGHT TO THE ATTENTION OF THE MECHANICAL CONTRACTOR. 6. THE LOCATIONS OF ALL ITEMS SHOWN ON THE DRAWINGS OR CALLED FOR IN THE DOCUMENTS THAT ARE NOT DEFINITELY FIXED BY DIMENSIONS ARE APPROXIMATE ONLY. THE EXACT LOCATIONS NECESSARY TO SECURE THE BEST CONDITIONS AND RESULTS MUST BE DETERMINED BY THE PROJECT SITE CONDITIONS AND SHALL HAVE THE APPROVAL OF THE ENGINEER BEFORE BEING INSTALLED. DO NOT SCALE DRAWINGS. 7. ALL ROOF PENETRATIONS SHALL BE MINIMUM OF 5 FEET AWAY FROM THE AREA/OCCUPATION SEPARATION WALLS. ALL PIPE, DUCT AND CONDUIT PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE FIRE AND SMOKE STOPPED PER CODE. 8. ALL EQUIPMENT, DAMPERS, PIPING, AND ACCESSORIES IN CONCEALED SPACES REQUIRING ACCESS SHALL HAVE ACCESS DOORS. ALL ACCESS DOORS IN FIRE RATED STRUCTURE SHALL BE FIRE RATED. COORDINATE LOCATIONS WITH ARCHITECT. CONTRACTOR TO PROVIDE ACCESS DOORS. 9. ALL EQUIPMENT SHALL BE FREE FROM DEFECTS IN MATERIAL, WORKMANSHIP, AND SHALL BE OF THE KIND AND QUALITY DESCRIBED HEREIN. 10. ALL EQUIPMENT SHALL BE APPROVED FOR INSTALLATION IN THE STATE OF WASHINGTON AND SHALL HAVE ALL CERTIFICATIONS AND RATINGS REQUIRED TO MEET ALL ENERGY, POLLUTION, ENVIRONMENTAL, SEISMIC, ETC. CODES AND REGULATIONS. 11. VERIFY ALL THE MECHANICAL EQUIPMENT'S ELECTRICAL LOADS VOLTAGE/PHASE, ETC. WITH ELECTRICAL CONTRACTOR PRIOR TO ORDERING. 12. WHERE MULTIPLE RISERS OR HORIZONTAL LOOPS ARE USED, BALANCING VALVES IN THE RETURN LINES ARE REQUIRED. A CHECK VALVE SHALL BE PROVIDED IN EACH RETURN TO PREVENT TEMPORARY REVERSAL OF FLOW. 13. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL COMPLETE AND OPERABLE MECHANICAL SYSTEMS AS INDICATED ON THE DRAWINGS, AS SPECIFIED AND AS REQUIRED BY IMC, UPC, IBC, WASHINGTON STATE ENERGY CODE AND ALL APPLICABLE LOCAL AMENDMENTS. 14. INSTALL ALL MECHANICAL EQUIPMENT AND APPURTENANCES IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS, CONTRACT DOCUMENTS, AND APPLICABLE CODES AND REGULATIONS. 15. COORDINATE CONSTRUCTION OF ALL MECHANICAL WORK WITH ARCHITECTURAL STRUCTURAL, ELECTRICAL WORK, ETC., SHOWN ON CONTRACT DOCUMENT DRAWINGS. 16. ALL TESTS SHALL BE COMPLETED BEFORE ANY MECHANICAL EQUIPMENT OR PIPING INSULATION IS APPLIED. 17. WHERE TWO OR MORE ITEMS OF THE SAME TYPE OF EQUIPMENT ARE REQUIRED, THE PRODUCT OF ONE MANUFACTURER SHALL BE USED. 18. LOCATIONS AND SIZES OF ALL FLOOR, WALL, AND ROOF OPENINGS SHALL BE COORDINATED WITH ALL OTHER TRADES INVOLVED. 19. REFER TO TYPICAL DETAILS FOR DUCTWORK, PIPING, AND EQUIPMENT INSTALLATION. 20. RECORD DRAWINGS SHALL BE PROVIDED TO THE OWNER WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE AS REQUIRED BY SECTION 1416.1 OF THE WSEC. THE DRAWINGS SHALL INDICATE THE LOCATION AND PERFORMANCE DATA OF EQUIPMENT, GENERAL CONFIGURATION OF DUCTWORK AND PIPING DISTRIBUTION SYSTEMS, INCLUDING FLOW RATES AS A MINIMUM, THAT HAVE BEEN DEVIATED FROM THESE DOCUMENTS. A COMPLETE RECORD OF CHANGES SHALL BE KEPT TO DATE ON A DAILY BASIS AND MADE ACCESSIBLE TO OWNER AND ENGINEER. 2012 WASHINGTON STATE ENERGY CODE (WSEC) NOTES 1. HVAC EQUIPMENT SHALL HAVE MINIMUM PERFORMANCE AT SPECIFIED RATING CONDITIONS NOT LESS THAN THE VALUES INDICATED IN C403.2.3. 2. HVAC SYSTEMS SHALL BE EQUIPPED WITH AUTOMATIC CONTROLS CAPABLE OF ACCOMPLISHING SETBACK OR SHUTDOWN DURING UNOCCUPIED PERIODS AS REQUIRED BY SECTION C403.2.4.3.2 OF THE WSEC AND AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES, IF PROVIDED. 3. PROVIDE BALANCING DEVICES IN ALL BRANCH DUCTS AND PIPE RUNS TO TERMINAL DEVICES AS REQUIRED BY SECTION C403.2.7.3 OF THE WSEC AND AS INDICATED ON THE CONTRACT DOCUMENTS. 4. ALL DUCTWORK SHALL COMPLY WITH SMACNA STANDARDS FOR CONSTRUCTION OF GALVANIZED DUCTWORK. ALL DUCTWORK SHALL BE SEALED AS REQUIRED BY SECTION C403.2.7 "DUCT AND PLENUM..." OF THE WSEC. DUCT TAPE NOT ALLOWED. 5. ALL DUCTWORK SHALL BE INSULATED AS REQUIRED BY SECTION C403.2.7 OF THE WSEC. 6. MOTOR EFFICIENCY SHALL NOT BE LESS THAN THE MINIMUM CALLOUTS PER C403.3.1 AND SECTION C403.2.13 OF THE WSEC FOR FULL LOAD EFFICIENCIES. 7. HVAC SYSTEMS SHALL BE BALANCED AS REQUIRED BY SEC11ON THE WSEC. 8. IF NOT SPECIFICALLY STATED ABOVE, CONTRACTOR SHALL COMPLY WITH THE WSEC ITEMS THAT DO APPLY TO THIS PROJECT. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. CE TAIN ITEMS SUCH AS RISES AND DROPS IN DUCTWORK, ACCESS DOORS, VOLUME DAMPERS, ETC. ARE INDICATED ON THE ila CO TRACT DOCUMENT DRAWINGS FOR CLARITY FOR A SPECIFIC LOCATION REQUIREMENT AND SHALL NOT BE INTERPRETED AS ISION EXTENT OF THE REQUIREMENTS FOR THESE ITEMS. 6. UNLESS OTHERWISE SHOWN, LOCATE ALL ROOM THERMOSTATS 4'-0" (CENTERLINE) ABOVE FINISHED FLOOR. NOTIFY THE ENGINEER OF ANY ROOMS WHERE THE ABOVE LOCATION CANNOT BE MAINTAINED OR WHERE THERE IS A QUESTION ON LOCATION. 7. ALL DUCTWORK SHALL CLEAR DOORS AND WINDOWS. 8. PROVIDE ALL 90 DEGREE SQUARE ELBOWS WITH DOUBLE RADIUS TURNING VANES UNLESS OTHERWISE INDICATED. PROVIDE ACCESS DOORS UPSTREAM OF ALL ELBOWS WITH TURNING VANES. 9. UNLESS OTHERWISE NOTED, ALL DUCTWORK IS OVERHEAD, TIGHT TO THE UNDERSIDE OF THE STRUCTURE (WITHIN TRUSSES), WITH SPACE FOR INSULATION IF REQUIRED. 10. MAXIMUM LENGTH OF FLEXIBLE DUCTS LOCATED ABOVE HARD CEILINGS SHALL BE AS CODE PERMITS BUT NO LONGER THAN 4 FEET. 11. ALL DUCTWORK SHALL BE COORDINATED WITH ALL TRADES INVOLVED. OFFSETS IN DUCTS, INCLUDING DIVIDED DUCTS AND TRANSITIONS AROUND OBSTRUCTIONS, SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER. 12. PROVIDE ACCESS DOORS IN DUCTWORK TO PROVIDE ACCESS FOR ALL VOLUME DAMPERS AND OTHER ITEMS LOCATED IN THE DUCTWORK WHICH REQUIRE SERVICE AND/OR INSPECTION. 13. ALL DUCTS SHALL BE GROUNDED ACROSS FLEXIBLE CONNECTIONS WITH FLEXIBLE COPPER GROUNDING STRAPS. GROUNDING STRAPS SHALL BE BOLTED OR SOLDERED TO BOTH THE EQUIPMENT AND THE DUCT. 14. MAKE ACCEPTABLE ACCESS PROVISIONS FOR REMOVAL OF FILTER AND MAINTENANCE FOR ALL INDOOR UNITS. 15. ALL AIR DISTRIBUTION SUPPLY OUTLETS AND RETURN/EXHAUST INLETS SHALL HAVE VOLUME CONTROL DEVICES. 16. ALL 90 DEGREE TRUNK DUCT ELBOWS SHALL BE SMOOTH -ROUND OR SQUARE WITH TURNING VANES. 17. CONTRACTOR SHALL LOCATE AND COORDINATE EXACT LOCATION OF DUCTWORK WITHIN THE STRUCTURE AT SITE. 18. ALL FAN SYSTEMS WITH OVER 2000 CFM SHALL HAVE SMOKE/DUCT DETECTORS TO SHUT -DOWN FAN UPON DETECTION. DUCT/SMOKE DETECTORS FURNISHED AND INSTALLED BY ELECTRICAL AND WIRED BY ELECTRICAL DUCT/SMOKE DETECTORS SHALL BE LISTED BY AN APPROVED AGENCY AND FOR INSTALLATION IN AIR DUCTS PER IMC. 19. ALL MECHANICAL HEATING\ AND VENTILATION EQUIPMENT SHALL CONFORM TO SMACNA, LOCAL AND STATE REGULATIONS FOR SEISMIC RESTRAINT (INCLUDING PIPING AND DUCTWORK). COORDINATE WITH STRUCTURAL 20. ALL RECTANGULAR DUCTWORK SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS. SUPPLY AND RETURN DUCTWORK FOR HVAC TO HAVE 1" SOUNDLINING FOR THE FIRST 10 FEET FROM UNIT DISCHARGE OUTLET. ALL DUCT LINING TOM T AND EXCEED MOLD, HUMIDITY, EROSION RESISTANT, ETC. TO MEET 1MC CHAPTER 6. ALL DUCTWORK TO BEFUEICOTS. CLASS -II DUCTS SHALL NOT BE USED. SITE INFO Permit No. M L O [2 O Plan review approval is subject to errors and omissions. ADDRESS: OWNER: 14220 INTERURBAN AVE S TUKWILA, WA 98168 BELLTOWN INVESTMENT PARTNER Appruvel of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy moons is acknowledged: By: Date: PARCEL/TAX # 3365901881 City of Tukwila BUILDING DIVISION HILLMANS SEATTLE GARDEN TRS POR OF LOT 1 & ALL OF LOTS 2 THRU 7 & POR ADJ IN SE 1/4 OF SECTION 14-23-04 DAF - BEG SE COR OF SAID LOT 7 TH NLY ALG ELY LN 315 FT TO LFT BANK OF DUWAMISH RIVER AS ORIGINALLY PLATTED TH CONTG ON NLY PROD OF SD ELY 220 FT M/L TO LFT BANK AS EXISTED UNDER SUPERIOR COURT CAUSE NO 81-2-05910-4 TH WLY ALG SD BANK TO AN INTSN WITH NELY PROD OF SELY LN OF NWLY 72 FT OF SD LOT 1 TH SWLY ALG SD LN PROD 200 FT M/L TO LFT BANK OF DUWAMISH RIVER AS PLATTED IN ORIGINAL PLAT TH CONTG IN SWLY DIRECTION ALG SELY .LN -OF NWLY 72 FT OF SD LOT 1 DISTANCE OF 55 FT M/L TO SWLY LN OF SD LOT 1 TH SELY ALG SD LN TO INTSN WITH N MGN OF S 143RD ST FIRST AVE TH ELY ALG SD MGN TO TPOB-TGW POR FOSTER JOSEPH DC #39 BEING POR OF ABANDONED PUGET SOUND ELECTRIC RR R/W IN THE SW 1/4 OF SE 1/4 OF SD SEC 14 SD RR R/W BOUNDED ON NE BY MAULE AVE ON SW BY A LN 20 FT NE OF & PLT NELY MGN OF SR 181 UNDER REC #8905231113 ON THE SE BY R/W #5 & ON THE NW BY R/W #6 BOTH R/W DEFINED IN QCD AUD FILE # 6557639 - TGW VAC MAULE AVE ADJ TGW POR VAC ST ADJ LEGAL: SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical 4 Etectricai Plumbing ta-Gas Piping City of Tukwila BUILDING DIVISION 3132 N.E. 133 ST Seattle, Washington 98125-4423 PO Box 27073 Seattle, Washington 98165-1473 (206) 367-2500 Fax (206) 368-6856 PSRHVMS924JT a. 0 CC U 0) t 1 COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. r 1 RECEIVED CITY OF TUKWILA JUN 1 0 2014 PERMIT CENTER 1 PERMIT SET 6.10-1,I `No. RevisionFlssue Date' Drawn By A. BONILLA 6-10-14 Lead Tech Engineered By Date GAS PACKAGED ROOFTOP UMT EQUIPMENT S I-ED i E IVIARK A-4 LOCATION UNIT ROOF NCNVINAL TONS 7.5 TOTAL C OSA CFM ON CYCLE 3000300 a300 10ae SP 0.5 HP/BI-P /1.69 COOLING TOTAL (MLA-1) 9(3,330 SENSIBLE (BTUH) 72,190 12 SEAT INPUT (N HEATING (NBH) 1201180 I 148 TBVP RISE 45.7 CFM 3000 SOUND DBA (DB) 82 ELECTRIC VOLTAGBPHASE 460V / 3PH MCA 21 MRCP (ANDS) 25 OPERATI NG WEIGHT: Lbs 1119 BASIS OF DESIGN IWANUFACr1.JRER CARRIER MODE_ SEFtVIES CORE AREAS CIF STEs 105, 130, 134, 160 REMARKS NEW UNIT SITE PLAN ayl NTS +OI246 Project P4909 Project anager N. SINGER VARIES Sheet M 0.0 <EY PLAN NTS NOTE: AREA OF WORK SITE REVIEWED FOR CODCOMPLIANCE APPROVED JUN 27 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 1 0 2014 PERMIT CENTER 3132 N.E. 133 ST Seattle, Washington 98125-4423 PO Box 27073 Seattle, Washington 98165-1473 (206) 367-2500 Fax (206) 368-6856 PSRHVMS924JT LA, WA 98168 COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. IN 1 PERMIT SET 6-10-14 `No. r Revisionllssue Date "'awn By A. B•NILLA 610-14 Lead Tech Engineered By Date rojed Sheet P4909 Project Manager N. SINGER Mal Scate AS NOTED �CIDER A.5 KEY PLAN SCALE NOTE: AREA OF WORK DEN 1 /16"=1' 0 PLAN / 28,_0" Unit flA-2 Unit #A-4 Unit fA-3 REVIEWED ANCE R CODE COM APPROVED JUN 27 2014 City of Tukwila BUILDING DIVISION pi-Unit flA-6 12'-0" /-- b CV V('*O1i6 RECEIVED CITY OF TUKWILA JUN 1 0 2014 PERMIT CENTER ro L) MI Ma rri 4— bJ A Service Logic Company 3132 N.E. 133 ST Seattle, Washington 98125-4423 PO Box 27073 Seattle, Washington 98165-1473 (206) 367-2500 Fax (206) 368-6856 PSRHVMS924JT THE SCHUSTER GROUP ¢ u0 • w Z� of �Q w m w U W • Z tY N N LA, WA 98168 1 COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. 1 PERMIT SET 6-10-14 `No. Revision/Issue Date' rawn By A.BONILLA 6--10-14 Lead Tech Engineered By Date roject Sheet P4909 Project Manager N. SINGER M 1 .0 Scale AS NOTED RMi1, �1 �A <EY PLAN SCALE NOTE: AREA OF WORK 0 0 0 0 Unit #A-2 28'-0" a rn 7— Unit fiA-4 n Unit #A-3 L ll 5 —0n HVAC PLAN 1 /16"=1' / REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 7 2014 City of Tukwila BUILDING DIVISION 1111-1.---01).0 RECEIVED CITY OF TUKWILA JUN 1 0 2014 PERMIT CENTER • rB co U N • • (13 F(0 'a l a) (73 LLJ CP i E A Service Logic Company 3132 N.E. 133 ST Seattle, Washington 98125-4423 PO Box 27073 Seattle, Washington 98165-1473 (206) 367-2500 Fax (206) 368-6856 PSRHVMS924JT 1 0 D 0 0 (/) 0 TLLI i 1 J COPYRIGHT NOTICE THIS LAYOUTIDESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. 1' 1 1 PERMIT SET 6-10-14 �No. Revisionllssue Date, Drawn By A. BONILLA 1 6--10-14 Lead Tech Engineered By Date 44 4, Project Sheet P4909 Project Manager N. SINGER M 2.0 Scale AS NOTED 2 r EXISTING 3'-6" PARAPET BUILDING A NORTH ELEVATION 1 /16" = 1'-0" r EXISTING 3'-6" PARAPET 11 EXISTING ROOF EXISTING ROOF J L lz BUILDING A EAST ELEVATION 1 /16" = 1'-0" BUILDI f- EXISTING 3'-6" PARAPET NG A SOUTH ELEVATION 1 /16" = 1'-0" /- EXISTING 3'-6" PARAPET EXISTING ROOF REVIEWED FOR CODE COMPLIANCE A PoROVED J;R. 7 ?014 !kwita 'VISION L EXISTING ROOF BUILDING A WEST ELEVATION 1 /16" = 1'-0" 100'-0" "CV CO 1n M 14m-0(2.0 RECEIVED CITY OF TUKWILA JUN 1 0 2014 PERMIT CENTER • ro ro ra (!) a) 4-- W A Service Logic Company 3132 N.E. 133 ST Seattle, Washington 98125-4423 PO Box 27073 Seattle, Washington 98165-1473 (206) 367-2500 Fax (206) 368-6856 PSRHVMS924JT i THE SCHUSTER GROUP w Z ow 5> z WCa Z U w N LL r TUKWILA, WA 98168 COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND PUGET SOUND REFRIGERATION HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREOF. i N 1 PERMIT SET 6-10-14 `No. Revision/Issue Date, Drawn By A. BONILLA 1 6 10-14 Lead Tech Engineered By Date J Project P4909 Project Manager N. SINGER AS NOT ED Sheet M 3.0 f