HomeMy WebLinkAboutPermit M14-0134 - LULULEMON - LANDLORD WORK - SPLIT SYSTEM HEAT PUMPS AND ROOF HOODSLULULEMON
LANDLORD WORK
21 S OUTh CENTER MALL
M14-0134
Parcel No:
Address:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.eov
MECHANICAL PERMIT
9202470130 Permit Number:
21 SOUTHCENTER MALL
Project Name: LULULEMON - LANDLORD WORK
Issue Date:
Permit Expires On:
M14-0134
7/21/2014
1/17/2015
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
WESTFIELD PROPERTY TAX DEPT
PO BOX 130940, CARLSBAD, WA,
92013
ALEX BURKHART
727 S KENYON ST , SEATTLE, WA,
98108
EVERGREEN REFRIGERATION LLC
727 S KENYON ST , SEATTLE, WA,
98108
EVERGRL954R2
Phone: (206) 763-1744
Phone: (206) 763-1744
Expiration Date: 1/6/2016
DESCRIPTION OF WORK:
INSTALLATION OF (2) SPLIT SYSTEM HEAT PUMPS AND (3) ROOF HOODS.
Valuation of Work: $25,635.00
Type of Work: NEW
Fuel type: ELECT
Fees Collected: $533.32
Electrical Service Provided by: PUGET SOUND ENERGY
Water District: TUKWILA
Sewer District: TUKWILA SEWER SERVICE
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
2012
2012
2012
2012
International Fuel Gas Code:
WA Cities Electrical Code:
WA State Energy Code:
2012
2012
2012
Permit Center Authorized Signature:
41_,L
Date: ['s)'"1-1 1-1
hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature: bA4—Th
Date: I
Print Name: 1 t3)1Arktiva-A—
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
9: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable
with the following concerns:
4: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be
separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance
#2437)
5: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings
shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the
power source of the air -moving equipment upon detection of smoke in the main return -air duct served by
such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall
be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1)
2: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437)
6: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City
Ordinance #2437)
7: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437)
3: All new fire alarm systems or modifications to existing systems shall have the written approval of The
Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been
obtained. (City Ordinance #2437) (IFC 901.2)
8: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required
for this project.
1: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances
#2436 and #2437)
10: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply
approval of such condition or violation.
11: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention
Bureau at (206)575-4407.
12: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
13: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
14: Readily accessible access to roof mounted equipment is required.
15: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
16: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
on satisfactory completion of this requirement.
17: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
18: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
19: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
20: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1400 FIRE FINAL
0703 MECH EQUIP EFF
1800 MECHANICAL FINAL
0705 REFRIGERATION EQUIP
0701 ROUGH -IN MECHANICAL
0702 SMOKE DETECTOR TEST
CITY OF TUKWL.1
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Mechanical Permit No.
Project No.
Date Application Accepted: \71° I�
Date Application Expires: 111
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION
Site Address: Z i 5)101 cam. k /I4 A
Tenant Name: W Lvlerm.bo
King Co Assessor's Tax No.: 121)2 Y76 (3 d
Suite Number: .1Floor: (
PROPERTY OWNER
Name: Wt5A-66(4 P,N(WLi T442
lcp''t .
Address: PD I),k 0 b evb
City: (fit 16/, a I State:
Zip:1 2,01 3
CONTACT PERSON — person receiving all project
communication
Name: Au t . itivoct-
Address:. -72150i)+1.1yda1 2'4
City:1_i.,i State: W�
Zip: ct $ b$
Phone: �6�- --1(;), (-Z`{.4 Fax: 24)6 - ]
3 `2 %4
Email: ejex l,,@ ettYLre )-1 va2 -G,+n
New Tenant: 0 Yes ❑ ..No
MECHANICAL CONTRACTOR INFORMATION
Company Name: �rcek1,
Address: 72'l h ,tf_a„ Sk ,
City: State: L✓ Zip: qi.di
Phone: Zri6= L63 _ 1- q Fax: Z-o6 --IC3 Z31h
Contr Reg No.: Duc.4 45,4l22Exp Date: ) 161 t6
Tukwila Business License No.: DU S _Oct 4 V?7 1
Valuation of project (contractor's bid price): $ 25 r C93 5 . co
Describe the scope of work in detail:
n5�i; t-;vLi d - -11.4)
L2 5p1' tvA 191.4"0s
Use: Residential: New ❑
Commercial: New []�
Fuel Type: Electric Er
Replacement
Replacement
+h(ke_ 63) hasis,
Gas ❑ Other:
H:\Applications\£orms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx
Revised: August 2011
bh
Page 1 of 2
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Furnace > 100k btu
Floor furnace
Suspended/wall/floor
mounted heater
Appliance vent
Repair or addition to
heat/refrig/cooling
system
Air handling unit
<10,000 cfm
Unit Type
Qty
Air handling unit
>10,000 cfm
Evaporator cooler
Ventilation fan
connected to single duct
Ventilation system
Hood and duct
Incinerator — domestic
Incinerator —
comm/industrial
Unit Type
Qty
Fire damper
Diffuser
Thermostat
Wood/gas stove
Emergency generator
Other mechanical
equipment
.L
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT: W/
Signature: Date: /(LI
*' ( Day Telephone: 2,6 6 3 "
Print Name:
Mailing Address: -7' 7 yy-h -470c-
City State Zip
H:\Applications\Forms-Applications On Line\2011 Applicatious\Mechanical Permit Application Revised 8-9-11.docx
Revised: August 2011
bh
Page 2 of 2
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
ACCOUNT
QUANTITY
PAID
$610.60
EL14-0626 Address: 21 SOUTHCENTER MALL Apn: 9202470130
$77.28
ELECTRICAL
$73.60
PERMIT FEE MULTI-FAM/COMM
R000.322.101.00.00
0.00
$73.60
TECHNOLOGY FEE
$3.68
TECHNOLOGY FEE
R000.322.900.04.00
0.00
$3.68
M14-0134 Address: 21 SOUTHCENTER MALL Apn: 9202470130
$533.32
MECHANICAL
$512.81
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$377.75
PLAN CHECK FEE
R000.322.102.00.00
0.00
$102.56
TECHNOLOGY FEE
$20.51
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R2488
R000.322.900.04.00
0.00
$20.51
$610.60
Date Paid: Monday, June 30, 2014
Paid By: EVERGREEN REFRIGERATION LLC
Pay Method: CHECK 006556
Printed: Monday, June 30, 2014 9:18 AM 1 of 1
SYSTEMS
3
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
ProjecZl f 1` 1 p �V�
r,. i
Type of�inspec�ti}o13
Address:
a) s(1 Ill t 1
Date Called:
Special Instructions:
Special
Date Wanted:
�L -'Z �-"�
�m,
P.m -
Requester:
Phone No:
tEApproved per applicable codes.
ElCorrections required prior to approval.
COMMENTS:
\ 1 A LA ,., ( i Yak/; (' a
--► spspeectorr:
R `INSPECTION FEE RiQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
Date:
►0-23--+f
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
r(11H-61311
Project:
L21 l7t Le o
Type of Inspection:
F- I LI P-) L.----
Address:
.-1 SO 0 (A t, L-
Date Called:
Special Instructions:
Date Wanted:
10 _2Z- ►t.l
f a:m:
-pITi:
Requester: +
Phone No:
Approved per applicable codes. TE Corrections required prior to approval.
COMMENTS:
(0 t`e1� %Lt' f\ L. _
-p.i'Sr(y_ '- io N
"i)
B A Later, >
_ ).1cQb'( \
3)
7;Ina K� ctiki
Z�
<jinpe tor: AQ Date: f
R gINSPECTION FEE RgCdUIRED. Prior t next inspection, fee must be
pd at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION N0. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
yvi
LI013 q
Project:
L- L�tLe►�iA(}"-S
Typ�o f In ection:
1�CC-� /eCcr
tD-NJ
Address:
G.I S d
AlA- (i
Date Called:
_ _.
Special Instructions:
Date Voted:
1- `
a.m.
Requester,: lL
P CJ,Ici
VC37
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
( I) c&e-((679P✓AT1b�-� X
X -
(o0di
El-) IV
‘
/ Xi
InSpector:
n RIEINSPECTION FEE REpUIRED. Pt,lior to
paid at 6300 Southcenter Blvd., Suite 100.
Date;
next inspection, fee must be
Call to schedule reinspection.
1-
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. P RMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Project:
L L A.t� WI
Type of Inspection:
I--- 1 NJ A
Address:
{
Date Called:
Special Instructions:
Date Wanted:
a.m.
Requester:
Phone No:
ElApproved per applicable codes.
Corrections required prior to approval.
COMMENTS: t" \
'",
�1 J I c dl tc't h - - .\ \((eyed .
._
1 n 10 (' Son c c- ( D3_,.,j kJ — 'V
/rc._../--)
�`de'
i
31 I ✓ c1K7-rA1 tJ A-/ r ---�
/t_) CL
\P
Inspec or:,
� r 1 ,\ A_J I t r.•1 )Gf J
f`-• 1 r
REINSFECTION FEE REQUIRED\ Prior to Next inspection, fee must be
pai d t 6300 Southcenter Blvd., St ite 100.ICatl to schedule reinspection.
Date: _
-�" z _ 1,
EVERGREEN REFRIGERATION, LLC
727 S KENYON ST.
SEATTLE, WA. 98108
206-763-1744
CONTR. # EVERGI201 D7
TEST AND BALANCE REPORT
Project: L -uL j L,144: 11/4)
Evergreen Job #:
Date: /a/a elq
Location: Z ( SovfNCfvAz-
Engineer: EVERGREEN REFRIGERATION LLC
Evergreen Refrigeration LLC, has balanced the system described in accordance
with the plans, specifications, and within the limitations of the equipment.
The testing, balancing, and adjusting has been performed in accordance with
industry standards. The results of these tests are herein recorded.
Commissioning Technician: gJid RAJ
Date completed: / p/Zp //t/
EVERGREEN REFRIGERATION, LLC
AIR OUTLET TEST REPORT - SUPPLY
Page 1
Project: LULL LFMMon.1
Job #:
Date:
Unit #
Area Served
Outlet
Design
Target
Preliminary
Final
No
Type
Size
C.F.M.
C.F.M.
C.F.M.
C.F.M.
C.F.M.
{--N- I
I, t
I-IZ 5
y''
1436.
y 3v
. 3
4/25
520
Y 110
143 0
i . 1-1
tal
`/70
h1 f
` oo
-
1-125
'--100
Ito
2)
I-1 - -
jC
113o
4l3
�.
142-"
1-l&v
yq o
AtZo
7',74L
3 vvry
29 .Sb
c25,4
boo
5'T0
14'11Z
2 c
- e5
3 oO
3, v
33 )
2.Z
333
34'°
310
3'n
_ 2.3
333
357?
3/U
35
2-44
33')
3 x.
3to
320
2-
33.
70
3kO
335 -
2 - Co
33 3
2V,
ago
3ti0
pL
2e,00
2a/---
2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3
Mechanical Summary
MECH-SUM
Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3
Revised June 2013
Project Info
Project Address 21 Southcenter Mall, Suite 748
Date 6/30/2014
Tukwila, WA 98188
For Building Dept. Use
Applicant Name: Alex Burkhart
Applicant Address: 727 South Kenyon St. Seattle, WA 98108
Applicant Phone: 206-763-1744 ext. 247
Project Description
Briefly describe mechanical
system type and features.
Q Includes Plans
Installation of two (2) split system heat pumps. FILE COPY
Permit No.
Drawings must contain notes requiring compliance with commissioning provisions per Section C408
Compliance Option
0 Simple System 0 Complex System 0 Systems Analysis
Equipment Schedules
The following information is required to be incorporated with the mechanical equipment schedules on
the plans. For projects without plans, fill in the required information below.
Cooling Equipment Schedule
Equip.
ID
Equip
Type
Brand Name'
Model No.1
Capacity2
Btu/h
OSA CFM
or Econo?
SEER
or EER
IPLV3
Econmizer
Option or
Exception
Heat
Recovery
Y/N
III-1 /
OII-1
Lennox
TAA090S4D-STD-230 /
TPA090S4S-230
92800
600
11
N/A
Econmizer
N
III-2 /
OII-2
Lennox
csx2727II8-060 /
TPA060S4-230
57000
400
13
N/A
Econmizer
N
Heating Equipment Schedule
Equip.
ID
Equip
Type
Brand Name'
Model No.1
Capacity2
Btu/h
OSA cfm
or Econo?
Input Btuh
Output Btuh
Efficiency4
Heat
Recovery
Y/N
III-1 /
OII-1
Lennox
TAA09054D-STD-230 /
TPA090S4S-230
88000
600
88000
88000
3 .30
N
III-2 /
OII-2
Lennox
cax2727IIB-060 /
TPA060S4-230
56000
400
56000
56000
•3 .36
N
Fan Equipment Schedule
Equip.
ID
Equip
Type
Brand Name'
Model No.1
CFM
SP1
HP/BHP
Flow ConFiCENED
f Service
CITY OF
TUKWILA
REVIEWED
FOR
CODE
COMPLIANCE
JUN
3 0 201k
APPROVED
Se
ce W
p r a E ui
ill ti q
P PEHMIT
ment Schedule
CENTCR
Equip
ID
Equi
Type
Brand Name'
Model No.1
Input
Capacity
Sub -
Category
EF7
Locatio1n of Service
City of Tukwila
DIVISION
H
.0_0
13U1LD1NG
' If available. 2 As tested according to Table C403.2.3(1)A thru C403.2.3(8). 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as
applicable. 5 Flow control types: variable air volume (VAV), constant volume (CV), or variable speed (VS). 6 Economizer exception number per
echanical Permit Plans Checklist - Page 1 of 3
MECH-CHK
2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3
Revised June 2013
Project Address 21 Southcenter Mall, Suite 748
Date 6/30/2014
The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012
WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages.
Applicability
(yes,no,na)
Code Section
Code Provision
Information Required
Location on
Plans
Building Department
Notes
GENERAL PROVISIONS
Equipment Sizing & Performance
YES
C403.2.1
Load calculations
Load calculations performed per ASHRAE Std 183 or equivalent per
Chapter 3
M 1
Yes
C403.2.2
Equipment and system
sizing
Output capacity of heating and cooling equipment and systems do not
exceed calculated loads, note exceptions taken
M1
Yes
C403.2.5
Minimum ventilation
Ventilation (natural or mechanical) provided per IMC; indicate mechanical
ventilation is capable of being reduced to minimum requirement per IMC
M1
Yes
C403.2.3 &
C403.2.3.2 &efficiency
C403.2.12.1
Equipment minimum
Provide equipment schedules or complete MECH-SUM tables with type,
capacity, efficiency, test standard (or other efficiency source) for all
mechanical equipment
M1
N/A
C403.2.13
Electric motor efficiency
Provide equipment schedule with hp, rpm, efficiency for all motors; note
except.
N/A
C403.2.10
Fan power limitation
Fan system motor hp or bhp does not exceed limits per Table
C403.2.10.1(1)
N/A
C403.2.10.3
& C403.2.13
Fractional hp fan motors
Indicate fan motors 1/12 to 1 hp are ECM type or meet minimum efficiency
req.
N/A
C403.2.3
Maximum air cooled chiller
capacity
Indicate air-cooled chiller capacity does not exceed air-cooled chiller limit
N/A
C403.2.1
Non-standard water-cooled
chillers
Full -load and NPLV values for water-cooled centrifugal chiller adjusted for
non-standard operational conditions
N/A
C403.2.12.1.2
Centrifugal fan cooling
towers
Large capacity cooling towers with centrifugal fan(s) meet efficiency
requirements for axial fan open circuit cooling towers
N/A
C403.2.3
Forced air furnace and unit
heaters
Indicate intermittent ignition or IID, flue/draft damper & jacket loss
N/A
C403.2.3.3
heating/cooling equipment Packaged electric
List equipment required to be heat pumps on schedule
N/A
C403.2.3.4
Humidification
Indicate method of humidification (note requirements for systems with
economizer)
HVAC System Controls & Criteria
Yes
C403.2.4.1
Thermostatic controls
Indicate locations of thermostatic control zones on plans, including
perimeter systems
M1
Yes
C403.2.4.1.1
Heat pump supplementary
heat
Indicate staged heating (compression/supplemental) & outdoor lock -out
temp
M1
Yes
C403.2.4.2
Setpoint overlap (deadband)
Indicate 5°F deadband minimum for systems controlling both heating &
cooling
M1
Yes
C403.2.4.3
Automatic setback and
shutdown
Indicate zone t-stat controls with required automatic setback & manual
override
M1
Yes
C403.2.4.3.3
Automatic (optimum) start
Indicate system controls that adjust equip start time to match load
conditions
NA 1
Yes
C402.4.5.2 &
C403.2.4.4
Dampers
Indicate location of OSA, exhaust, relief and return air dampers; include
AMCA rated leakage and control type (motorized or gravity; note exceptions
M1
Yes
C403.2.11
Heating outside a building
Indicate radiant heat system and occupancy controls
M 1
N/A
C403.2.4.5
Snow melt systems
Indicate shut-off controls based on outdoor conditions
N/A
C403.2.4.6
Combustion heating
equipment
Indicate modulating or staged control
N/A
C403.2.4.7
Group R1 hotel/motel
systems
Indicate method for guest room automatic setback & set-up of 5°F
minimum
N/A
C403.2.4.8 / g
Group R2/R3 dwelling unit
systems
Indicate 5-2 programmable thermostats in primary spaces with minimum of
two setback periods; note exceptions taken
Yes
C403.2.5.1
ventilation Demand controlled
Indicate high -occupancy spaces and systems requiring DCV
M1
Yes
C403.2.5.2
Occupancy sensors
Indicate spaces requiring occupancy -based system control and method; or
alternate means provided to automatically reduce OSA when partially
M 1
Yes
C403.2.5.3
Enclosed loading
dock/parkinggarage
ventilationionsystem
Indicate enclosed loading dock and enclosed parking garage ventilation
activation and control method
M1
N/A
C403.2.5.4.1
Kitchen exhaust hoods
Indicate kitchen hoods requiring make-up air; indicate make-up air source
and conditioning method
N/A
C403.2.5.4.2
Laboratory exhaust systems
Indicate lab exhaust systems requiring heat recovery, method & efficiency;
or altemative method taken (VAV, semi -conditioned makeup, or CERM
calculation)
N/A
C403.2.6.1
Energy recovery -
ventilation systems
Indicate ventilation systems requiring ER, method & efficiency; note
exceptions
N/A
C403.2.6.2
Energy recovery -
condensate systems
Indicate on -site steam heating systems requiring energy recovery
N/A
C403.2.6.3
Energyrecovery -
condenser systems
Indicate remote refrig. condensers requiring ER and use of captured energy
Mechanical Permit Plans Checklist - Page 2 of 3
MECH-CHK
. 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3
Revised June 2013
Project Address 21 Southcenter Mall, Suite 748
Date 6/30/2014
The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012
WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages.
Applicability
(yes,no,na)
Code Section
Code Provision
Information Required
Location
on Plans
Building Department
Notes
GENERAL PROVISIONS, CONTINUED
HVAC System Controls & Criteria, Continued
N/A
C403.2.12
Variable flow control -
fans/pumps
Indicate fan & pump motors requiring VF control & method (VSD or equiv
controls)
N/AInC403.2.12.1Var
ltowerslow control
cooling
dicate cooling tower fans requiring variable flow control and method
N/A
C403.2.12.2
Large volume fan systems
Indicate fan systems requiring airflow reduction based on heating and
cooling demand; or exception taken
N/A
C403.2.12.2
Single zone AC systems
Indicate method of cooling demand -based fan control for sys. > 110,000
btuh
N/A
C403.2.4.10
DDC system capabilities
Identify all DDC system input/output control points and indicate capability
for trendina and demand resoonse setooint adiustment
Ducting Systems
Yes
C403.2.7.1 &Duct
C403.2.7.3
construction
Indicate all ductwork constructed and sealed per IMC, C402 leakage
requirements and IBC vapor retarder requirements
M 1
N/A
�403.2.7.3.1 ;
Duct pressure
classifications
Identify location of low, medium and high pressure ductwork on plans
N A
/
C403.2.7.3.3
High pressure duct leakage
test
Indicate high pressure duct leakage testing requirements on plans; provide
test results to jurisdiction when completed
Yes
C403.2.7.1 / 2
Duct insulation
Indicate R-value of insulation on ductwork
M1
Piping Systems
N/A
C403.2.8
Piping insulation
Indicate R-value of insulation on piping
N/A
C403.2.8.1
Piping insulation exposed to
weather
Indicate method of protection from damage/degredation
SIMPLE SYSTEMS
Qualifying Systems
Yes
C403.3
Qualifying single zone
systems
Verify unitary or packaged equipment does not exceed capacity limits,
does not have active humidifcation or simultaneous heating/cooling
M 1
N/A
C403.3
ing 2-pipe heating
systems
Verify 2-pipe heating -only system does not exceed capacity limits
N/A
C403.3.2
Hydronic system controls
Refer to Complex Systems Section C403.4.3
Simple System Economizers
Yes
C403.3.1
Air economizer required
Indicate cooling systems requiring economizer controls; note in equip
sched.
M1
Yes
C403.3.1.1.1
Air economizer capacity
Indicate modulating OSA control capability up to 100% OSA, or exception
M1
Yes
C403.3.1.1.3
controls Air economizer high limit
Indicate high limit shut-off control method per Table C403.3.1.1.3(2)
M 1
Yes
C403.1.1.2
Integrated air economizer
operation
Indicate capability for partial air economizer operation for systems with
capacity > 65,000 btuh
M 1
Yes
C403.3.1
Air economizer exceptions
___
Indicate eligible exception(s) taken and provisions to comply with
exceotion(s)
M1
COMPLEX SYSTEMS
Complex System Economizers
Yes
C403.4.1
Air economizer required
Indicate cooling systems requiring economizer controls; note in equip
sched.
M1
Yes
C403.4.1.4
Economizer heating system
impact
Verify control method of HVAC systems with economizers does not
increase building heating energy usage during normal operation
M1
Yes
C403.4.1.3
Integrated economizer
operation
Indicate capability for partial economizer operation for air or water econo
systems
M 1
N/A
Moved
Water economizer capacity
Indicate water econo capable of 100% cooling capacity at 50°F db/45°F wb
OSA
N/A
C403.4.1.2
Water economizer
maximum pressure drop
Indicate precooling coils and heat exchangers do not exceed pressure
drop limit
N/A
C403.3.1
Air economizer exceptions
Indicate eligible exception(s) taken and provisions to comply with
exceotion(s)
Mechanical
Permit Plans Checklist - Page 3 of 3
MECH-CHK
Revised June 2013
2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3
Project Address 21 Southcenter Mall, Suite 748
Date 6/30/2014
The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012
WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages.
Applicability
(yes,no,na)
Code Section
Code Provision
Information Required
Location on
Plans
Building Department
Notes
COMPLEX SYSTEMS, CONTINUED
Specific System Requirements
N/A
C403.4.2 &
c403.2.12
Variable flow control - fans
Indicate fans requiring variable flow control and method
N/A
C403.4.2.1
VAV fan static pressure
sensors
Indicate sensor locations on plans; include at least one sensor per major
duct branch
N/A
C403.4.2.2
VAV fan static pressure
setpoint
Indicate fan system static pressure setpoint based on zone requiring most
pressure
N/A
C403.4.5
VAV systems serving multi-
zones
Indicate supply air systems serving multiple zones that are required to be
VAV, method of primary air control, and zones served; note exceptions
taken
N A
/
C403.4.5.4
VAV system supply air reset
Indicate controls that automatically reset supply air temp in response to
loads
N/A
C403.4
Large capacity cooling
systems
Indicate method of multi -stage or variable control for building cooling
system capacity> 300 tons
N/A
C403.4.7
Hot gas bypass limitation
Indicate cooling equipment unloading or capacity modulation method
N/A
C403.4.3
systems Large capacity boiler
Indicate multi -stage or modulating bumer for single boilers > 500,000 btuh
N/A
C403.4.3
Boiler sequencing
Indicate automatic controls that sequence operation of multiple boilers
N/Aisolation
C403.4.3.5
Chiller / boiler plant pump
Indicate capability to automatically reduce overall plant flow and shut-off
flow through chillers & boilers when not in use
•
N/A
C403.4.2 &
C403.4.3.6
Variable flow control -
pumps
Indicate pumps requiring variable flow control & method
N/A
C404
& C403.4.4 03.4.4
Variable flowcontrol -
cooling towers
Indicate cooling tower fans requiring variable flow control and method
N/A
C403.4.3.4
Hydronic system part load
controls
Indicate heating & chilled water systems have the capability to automatically
reset supply water temp AND reduce flow by >_ 50 % for systems > 300,000
N/A
C403.4.3.2
Two -pipe changeover
systems
Indicate deadband, heating/cooling mode scheduling and changeover
temperature range
N/A
C403.4.3.3.1
Water loop heat pump -
deadband
Indicate capability of central equipment to provide min. 20°F water supply
temp deadband between heat rejection and heat addition modes
N/A
C403.4.3.3
Water loop heat pump -
heat rejection
Provide heat exchanger that separates cooling tower and heat pump loop
in Climate Zone 5
N/A
C403.4.3.3.3
Water loop heat pump -
isolation
Indicate 2-way isolation valve on each heat pump and variable flow control
for systems with total pump power > 10 hp
N/A
C403.4.6
Condenser water heat
recovery
Indicate system provided to pre -heat service water and efficiency
N/A
C403.5
Cooler / freezer - anti -sweat
heaters
Indicate w/sf & control method for walk-in cooler/freezer door anti -sweat
heaters
N/AC403.5
/ 6
Cooler / freezer - evaporator and condenser fans
Indicate motor type for evaporator and condenser fans < 1 hp
SERVICE WATER HEATING
Service Wa er Systems
N/A
C404.2
Water -heating equip min.
efficiency
Provide equipment schedule or complete MECH-SUM table with type,
capacity, efficiency, test standard (or other efficiency source)
N/A
C404.3
Temperature controls
Indicate temperature controls have required setpoint capability
N A
/
C404.4
Heat traps
Indicate piping connected to equipment have heat traps on supply &
discharge
N/A
C404.5
Insulation under water
heater
Indicate R-10 insulation under tank
N/A
C404.6
Service water piping
insulation
Indicate R-value of insulation on piping; note exceptions taken
N/A
C404.7 / g
Circulation systems and
heat trace shut-off
Indicate shut-off capability based on occupancy and periods of limited
demand
N/A
C404.9
Group R-2 service hot water
meters
Indicate method of usage metering for dwell. units served by central HW
system
Pools & In -Ground Permanently Installed Spas
N/A
C404.10.1
Pool heating equip min.
efficiency
Provide equipment schedule or complete MECH-SUM table with type,
capacity, efficiency, test standard (or other eff. source); heat pump heaters
_> 4 COP
N/A
C404.10.1 / 2
Pool heater on / off controls
Indicate automatic on/off control based on scheduling & accessible on/off
switch on heater that operates independent of thermostat setting; or
N/A
C404.10.3
Pool covers
Indicate vapor retardant cover and insulation rating as required
N/A
C404.10.3
Pool assembly insulation
Indicate rating of insulation on sides and bottom of pools heated to > 90°F
N/A
C404.10.4
Heat recovery
Indicate method, exhaust air temperature reduction and recovered energy
.use
C T
ENGINEERING
i INC.
FILE COPY
STRUCTURAL CALCULATIONS
Replacement Roof Top Units
Lululemon
Southcenter Mall
Tukwila, WA
180 Nickerson St.
Suite 302
Seattle, WA
98109
(206) 285-4512(V)
(206) 285-0618(F)
Scope of Work: Replace two Roof Top Mounted Units (7.5 ton and 5 ton) on
the existing concrete pad. No change to the existing roof structure required.
Code: IBC
Loads: Unit
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUL 1 1 2014
City of Tukwila
BUILDING DIVISION
Structural Engineers
2012
435# (7.5 Ton); 255# (5 Ton)
06/30/2014
RECEIVED
CITY OF TUKWILA
JUN 3 0 2014
PERMIT CENTER
AA I 0 I
C T
ENGINEERING
1 N C.
Project' L�IY►ta/c/ /�'1t
Date:
4.6c, /2av*
180 Nickerson St.
Suite 302
Seattle, WA
98109
(206) 285-4512
170l IC.G��(05te 4174' PAX:
Client: Page Number: (206) 285-0618
/).evJ6e i':" itGocAttg 77i'v K.T7r s:
40441704 Sailre NIZ410 rn `frti wt sr okiP .evee5
/Zi .l?V14-," 2t?/2 /#3 .
gu rfrr ex.? 1 Rvt , itOYGR exu5i7,46 «/
,v d vN:rf
>rP 00oS4t? -OT0'30 3
nosh DGo$ - 2; a
eel< 27uH - aeoo`
•
5.3 -
pG/row S Gas, mood c e,do-i ✓e.. elLi'rj
s'P ,' Se/We 140E/ l.'_`
/11/ Ninrvrot oP- ead
Structural Engineers
Lennox Industries Inc. - Product Submittal
Table of Contents
System ID
Qty
Model
Description
TPA090S4S 23(
TAA090S4D ST
UMP/75TON/230 3
IL/7.5T/230-3/STD;
5-TON SPLIT SYSTEM
1
1
TPA060S4-230
CBX27UH-060
HEAT PUMP/STON/230-3
FAN-COIL/5TON/230-1
Project: 3000428834 Lululemon Southcenter Mall
Quote: 4000509625 Lululemon Southcenter Mall
Page 2of11
Last Changed: DAN A. GIVENS
Prepared On: 2014-06-25
Phone: 206-763-1744
Lennox Industries Inc. - Product Submittal
,System ID: 7.5-TON SPLIT SYSTEM
Condenser Model: TPA090S4S-230
Evaporator Coil Model: TAA090S4D-STD-230
Description: HP/7.5TON/230-3
Description: FCOIL/7.5T/230-3/STD
HEATING PERFORMANCE
Heat Source
HP Output@47°
HP COP@47°
H/E HighOutput
Electric
88000 (Btuh)
3.30
64115 (Btuh)
HP DesignTemp
HP Output@17°
HP COP@17°
Electric Heater
H/E Heat Rise
17.0 (°F)
50000 (Btuh)
2.20
25.0 (kW)
19.8 (°F)
COOLING PERFORMANCE
Refrigerant
ARI EER
ARI NetTotalCool
Coil GrossTotalCool
Unit NetTotalCool
Coil GrossSensCool
Unit NetSensCool
Cond Liquid Line
Cond Suction Line
Coil Liquid Line
Coil Suction Line
R-410A
11.0
92300 (Btuh)
92800 (Btuh)
87780 (Btuh)
67744 (Btuh)
62724 (Btuh)
5/8 (in.)
1 3/8 (in.)
(2) 5/8 (in.)
(2) 7/8 (in.)
Number Compressors
Number of Cooling Stages
Cooling OutdoorDB
Cooling CondenserDB
Cooling MixedDB
Cooling MixedWB
Coil DischargeDB
Coil DischargeWB
Unit DischargeDB
Unit DischargeWB
Coil MoistureRemoval
System MoistRemoval
1
1
95.0 (°F)
95.0 (°F)
80.0 (°F)
67.0 (°F)
57.8 (°F)
56.7 (°F)
59.4 (°F)
57.3 (°F)
23.6 (lb/hr)
23.6 (1b/hr)
SUPPLY FAN PERFORMANCE
Supply AirFlow
ExtStaticPress Supply
SupplyFan Req'dPower
SupplyFan NomPower
Supply Fan Type
SupplyDriveReq'd RPM
SupplyDrive Min RPM
SupplyDrive Max RPM
3000 (cfm)
0.60 (in.WC)
1.58 (hp)
2.00 (hp)
CAV Belt Drive
807 (rpm)
782 (rpm)
1012 (rpm)
TotalStaticPress
0.60 (in.WC)
ELECTRICAL
Voltage
Air Handler Voltage
Frequency
Condenser MCA
Condenser MOCP
Cond Oper Range-Nom Voltage
Unit Oper Range-Nom Voltage
208V 3Ph
208V 3Ph
60 (Hz)
38.0 (amp)
60 (amp)
+/- 10%
+/- 10%
AirHandler MCA-1
AirHandler MOCP-1
SupplyFan FLA
75.0 (amp)
80 (amp)
7.5 (amp)
DIMENSIONS
CondensingUnit Height
CondensingUnit Width
CondensingUnit Length
Coil/Coil Fan Height
Coil/Coil Fan Width
Coil/Coil Fan Length
45.3 (in.)
57.9 (in.)
41.4 (in.)
54.8 (in.)
29.5 (in.)
51.3 (in.)
CondensingUnit Weight
435 (lb)
SOUND
Outdoor Sound Rating
85 (db)
Project: 3000428834 Lululemon Southcenter Mall
Quote: 4000509625 Lululemon Southcenter Mall
Page 3 of 11
Last Changed: DAN A. GIVENS
Prepared On: 2014-06-25
Phone: 206-763-1744
Lennox Industries Inc. - Product Submittal
System ID: 5-TON SPLIT SYSTEM
Condenser Model: TPA060S4-230
Evaporator Coil Model: CBX27UH-060
Description: HEATPUMP/5TON/230-3
Description: FANCOIL/5TON/230-1
HEATING PERFORMANCE
Heat Source
HP Output@47°
HP COP@47°
H/E HighOutput
Electric
56000 (Btuh)
3.36
38469 (Btuh)
HP DesignTemp
HP Output@17°
HP COP@17°
Electric Heater
H/E Heat Rise
17.0 (°F)
36400 (Btuh)
2.44
15.0 (kW)
17.8 (°F)
COOLING PERFORMANCE
Refrigerant
ARI EER
ARI SEER
ARI NetTotalCool
Coil GrossTotalCool
Unit NetTotalCool
Coil GrossSensCool
Unit NetSensCool
Cond Liquid Line
Cond Suction Line
Coil Liquid Line
Coil Suction Line
R-410A
11.0
13.0
57000 (Btuh)
61599 (Btuh)
58421 (Btuh)
47553 (Btuh)
44376 (Btuh)
3/8 (in.)
1 1/8 (in.)
3/8 (in.)
7/8 (in.)
Number Compressors
Number of Cooling Stages
Cooling OutdoorDB
Cooling CondenserDB
Cooling MixedDB
Cooling MixedWB
Coil DischargeDB
Coil DischargeWB
Unit DischargeDB
Unit DischargeWB
Coil MoistureRemoval
System MoistRemoval
1
1
95.0 (°F)
95.0 (°F)
80.0 (°F)
67.0 (°F)
56.6 (°F)
56.6 (°F)
58.2 (°F)
57.3 (°F)
13.2 (lb/hr)
13.2 (lb/hr)
SUPPLY FAN PERFORMANCE
Supply AirFlow
ExtStaticPress Supply
SupplyFan Req'dPower
SupplyFan NomPower
Supply Fan Type
SupplyDrive Speed
2225 (cfm)
0.50 (in.WC)
1.00 (hp)
1.00 (hp)
CAV Direct Drive
HIGH
TotalStaticPress
0.50 (in.WC)
ELECTRICAL
Voltage
Air Handler Voltage
Frequency
Condenser MCA
Condenser MOCP
Cond Oper Range-Nom Voltage
Unit Oper Range-Nom Voltage
208V 3Ph
208V 3Ph
60 (Hz)
21.3 (amp)
35 (amp)
+/- 10%
+/- 10%
AirHandler MCA-1
AirHandler MOCP-1
49.0 (amp)
50 (amp)
DIMENSIONS
CondensingUnit Height
CondensingUnit Width
CondensingUnit Length
Coil/Coil Fan Height
Coil/Coil Fan Width
Coil/Coil Fan Length
42.5 (in.)
28.3 (in.)
28.3 (in.)
62.5 (in.)
21.3 (in.)
24.9 (in.)
CondensingUnit Weight
255 (lb)
SOUND
Outdoor Sound Rating
80 (db)
Project: 3000428834 Lululemon Southcenter Mall
Quote: 4000509625 Lululemon Southcenter Mall
Page 8 of 11
Last Changed: DAN A. GIVENS
Prepared On: 2014-06-25
Phone: 206-763-1744
,'ERMR COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M14-0134
DATE: 06/30/2014
PROJECT NAME: LULULEMON - LANDLORD WORK
SITE ADDRESS: 21 SOUTHCENTER MALL
X Original Plan Submittal
Response to Correction Letter #
Revision #
Revision #
before Permit Issued
after Permit Issued
DEPARTMENTS:
kr Attic
Building Division
Public Works ri
4w\ /ittc,
Fire Prevention
Structural
n
Planning Division
Permit Coordinator
PRELIMINARY REVIEW:
Not Applicable
(no approval/review required)
DATE: 07/01/14
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
Approved with Conditions
Denied
(corrections entered in Reviews) (ie: Zoning Issues)
DUE DATE: 07/29/14
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
EVERGREEN REFRIGERATION LT
Page 1 of 3
0 Washington State Department of
Labor & Industries
EVERGREEN REFRIGERATION LLC
Owner or tradesperson
PATTON, RODGER
Principals
PATTON, RODGER, PARTNER/MEMBER
PATTON, MATTHEW, PARTNER/MEMBER
Patton, Adam, PARTNER/MEMBER
Patton, Douglas, PARTNER/MEMBER
EVERGREEN REFRIGERATION
LLC, PARTNER/MEMBER
PATTON, DAVID, PARTNER/MEMBER
(End: 01/21/2014)
Doing business as
EVERGREEN REFRIGERATION LLC
WA UBI No.
602 512 953
727 S KENYON ST
SEATTLE, WA 98108
206-763-1744
KING County
Business type
Limited Liability Company
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor
License specialties
GENERAL
License no.
EVERGRL954R2
Effective — expiration
01/06/2006— 01/06/2016
Bond
Merchants Bonding Co (Mutual)
Bond account no.
WA15097
Active.
Meets current requirements.
$12,000.00
Received by L&I Effective date
12/15/2011 01 /01 /2012
Expiration date
Until Canceled
TRAVELERS CAS & SURETY CO $12,000.00
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602512953&LIC=EVERGRL954R2&SAW= 07/21/2014
VICINITY MAP
SCALE : NONE
COMMISSIONING PLAN
ALL COMMISSIONING OF HEATING, VENTILATION AND AIR C❑NDITI❑NING SYSTEMS AS
REQUIRED BY SECTION C408 'SYSTEM C❑MMISSI❑NING' OF THE 2012 WASHINGTON STATE
ENERGY CODE (WSEC) SHALL BE PERFORMED BY EVERGREEN REFRIGERATION, LLC. THE
ACTIVITIES TO BE ACCOMPLISHED ARE PER THE SECTIONS LISTED IN THE
'C❑MMISSI❑NING COMPLIANCE CHECKLIST' SHOWN BELOW. AT THE COMPLETION OF THE
ACTIVITIES REQUIRED FOR C❑MMISSI❑NING AS DEFINED BY SECTION C408 OF WSEC
THE 'COMMISSI❑NING COMPLIANCE CHECKLIST' WILL BE REVIEWED WITH THE
BUILDING OWNER OR THE OWNER'S REPRESENTATIVE AND THIS CERTIFICATION WILL
BE SIGNED AND DATED, THIS WILL SATISFY TO THE CODE OFFICIAL THAT THE REPORT
HAS BEEN ACCEPTED AS REQUIRED BY SECTION C408.1,2.1 OF WSEC.
Project
Information
COMMISSIONING COMPLIANCE CHECKLIST
Project Name:
Project Address:
Commissioning Authority:
Commissioning
Plan
(Section
C408.1.1)
Commissioning Plan was used during construction and Included Items below
• A narrative description of activities and the personnel Intended to accomplish each one
• Measurable criteria for performance
• Functions to be tested
Systems
Balancing
(Section
C408.2.2)
❑
Systems Balancing has been completed
• Air and Hydronic systems are proportionately balanced In a manner to first minimize throttling losses
• Test parts are provided an each pump for measuring pressure across the pump
Functional
Testing
(Sections
C408.2.3)
❑ HVAC Equipment Functional Testing has been completed (Section C408.2.3.1)
HVAC equipment has been tested to demonstrate the Installation and
operation of components, systems and
system -by -system Interfacing relationships In accordance with approved
plans and specifications
❑ HVAC Controls Functional Testing has been completed (Section C408.2.3.2)
HVAC control have bee tested to ensure that control devices are
calibrated, adjusted and operate property.
Sequences of ope atlon have been functionally tested to ensure they
operate In ace trance with approved
plans and specifications
❑ Economizers Functional Testing has been completed (Section C408.2.3.3)
Economizers operate In accordance with manufacturer's specifications
Supporting
Documents
(Section
C408.1,3,2)
• Manuals, record documents and training have been completed or are scheduled
• System documentation has been provided to the owner or scheduled dates
• Record documents have been submitted to owner or scheduled date!
• Training has been completed or scheduled date
Commissioning
Report
(Section
C408.1.2)
Preliminary Commissioning Report submitted to Owner and Includes Items below
• Deficiencies found during testing required by this section which have not been corrected at the time of
report preparatlon
• Deferred tests, which cannot be performed at the time of report preperation due to climatic conditions.
Certification
❑ I hereby certify that all requirements for Commissioning have been
completed In accordance with the Washington State Energy Code,
Including all items above,
Building Owner or Owner's Representative
Date
SPLIT
SYSTEM EQUIPMENT
SCHEDULE
MARK
MANF.
MODEL •
TONS.
AIRFLOW
SP
DRIVE
POWER
MIN. OSA
COOLING
HEATING@47°
ELECTRICAL
WEIGHT
NOTES
CFM
WG
STYLE
HP
CFM
TOTAL
SEER
EER
OUTPUT
C.O.P.
VOLTS
PHASE
M.C.A.
BTUH
BTUH
(V)
(A)
LBS
IU-1.
LENNOX
TAA090S4D-STD-230
7.5
3000.
0.6
BD
2.00
600.
-
---
--
-
208
30
75.0
181
1
OU-1
LENNOX
TPA090S4S-230
7.5
---
-
--
--
---
92,800 .
-
11.0
88,000
3.30
208
30
38.0
435
IU-2
LENNOX
CBX2727UH-060
5 •
2000
0.5
DD
1.00
400
---
---
-
-
208
30
49.0
181
.1
OU-2
LENNOX
TPA060S4-230 •
5
---
---
---
--
--
57,000
13.0
11.0
56,000
3.36
208
30
21.3
255
NOTES: 1. THE AIR HANDLING UNIT COMES COMPLETE WITH AN ECONOMIZER
SEPARATE PERMIT
REQUIRED FOR:
❑ Mechanical
lectricai
13IBiumbing
r as Piping
T Tukwila
Bi,; . " DIVISION
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
FILE COPY
Permit No. MI'+o %3'l
Plan review approval is subject to errors and omissions.
Approval of construction documents does not authorize
t' is violation of any adopted code or ordinance. Receipt
cl approved Field Copy and conditions is acknowledged:
By: AA ---
Date: -7 12(/t
City of Tukwila
BUILDING DIVISION
GENERAL NOTES
DUCTWORK
1.1 ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH
DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4"TO EACH DIMENSION IF
DUCTWORK IS ON THE EXTERIOR OF BUILDING.
1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND
NUMBER IS THE HEIGHT.
1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING
LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER
IMC 602.2.1.
1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN
1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT
PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED
IN ACCORDANCE WITH STANDARD RS-7.
1.5 ALL DUCT GAUGES PER SMACNA, IMC 603-4.
1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603-10.
1.7 ATTACH DIFFUSERS AND GRILLES TO T-BAR GRID PER WA STATE & LOCAL CODES.
1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS.
INSULATION
2.1 INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES.
2.2 INSULATE REFRIGERANT & CONDENSATE PIPING PER STATE & LOCAL ENERGY CODES.
GENERAL CONTRACTOR
3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP,
CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING
AND FIRE PROOF LINING PER IMC & IBC.
3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS
WITH ERL BEFORE FRAMING OPENINGS.
3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING
AS REQUIRED FOR MECHANICAL WORK.
3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS
REQUIRED FOR MECHANICAL WORK.
3.5 GENERAL CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR
MECHANICAL WORK.
3.6 GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL
MECHANICAL EQUIPMENT.
3.7 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERL PROVIDE
ALL CANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS.
3.8 GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OF T-BAR CEILING
AS REQUIRED FOR HVAC INSTALLATION.
3.9 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED
FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL
BUILDING CODE, WHERE REQUIRED BY SECTION 707 OF IBC.
ELECTRICAL
4.1 ERL TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED
BY ELECTRi SAL CONTRACTOR.
4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS,
DISCONNECTS, AND STARTERS FOR MECHANICAL EQUIPMENT.
4.3 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS
WITH ERL MECHANICAL PLAN AND WITH FIELD CONDITIONS.
4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT
SWITCH.
4.5 ERL TO PROVIDE 7-DAY NIGHT SETBACK, PROGRAMMABLE TYPE T-STAT WITH
CAPABILITY OF 5°F DEADBAND.
4.6 ERL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER.
4.7 ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL GCFI OUTLET WITHIN 25 FT
OF EACH PIECE OF MECHANICAL EQUIPMENT.
PLUMBING
5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR
MECHANICAL EQUIPMENT PER CODE.
5.2 PLUMBING CONTRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH
AIR INTAKES OR 2' ABOVE HIGHEST POINT OF INTAKE, IMC 401.4.1.
5.3 • CONDENSATE DRAINS FROM RTU BY ERI TO DRAIN WITHIN 12" OF UNIT.
CONDENSATE DRAINS FOR AIR HANDLERS BY PLUMBER.
ENERGY CODE COMPLIANCE
6.1 AT A MINIMUM, EACH FLOOR IS TO BE CONSIDERED A SEPARATE ZONE. VERIFY
THERMOSTATIC CONTROL FOR EACH ZONE AS INDICATED ON PLANS.
6.2 OUTSIDE AIR INTAKES, EXHAUST OUTLETS, AND RELIEF OUTLETS SERVING
CONDITIONED SPACES SHALL BE EQUIPPED WITH DAMPERS WHICH CLOSE
AUTOMATICALLY WHEN THE SYSTEM IS OFF OR UPON POWER FAILURE,
PER WSEC SEC. C402.4.5.4
6.3 AIR ECONOMIZERS WHERE REQUIRED BY CODE ARE INDICATED BY THE EQUIPMENT
SCHEDULE AT 100% CAPABILITY, CONTROL AND OPERATION OF THE ECONOMIZER
SHALL COMPLY WITH WSEC SEC. C403.4.1
MECHANICAL CODE COMPLIANCE
7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS
IN EACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM.
DETECTORS SHALL BE LOCATED IN THE MAIN RETURN AIR PER IMC 606.
VA2012
SYMBOL
LEGEND
SYMBOL
ABBV.
DESCRIPTION
A
DUCT SECTION SUPPLY
ra
DUCT SECTION - RETURN/EXHAUST
RECTANGULAR DUCT
14'x8'
14'
ROUND DUCT
REVIEWED FOR
FLEXIBLE DUCT
CODE COMPLIANCE
APPROVED
MVD
MANUAL VOLUME DAMP
_R JUL 1 1 2014
1
7 I
❑BDD
BDD
BACKDRAFT DAMPER
'W`
I
MD
MOTORIZED DAMPER
City of Tukwila
BUILDING ENVISION
1
i
FD
FIRE DAMPER
-4
-+
FSD
FIRE/SMOKE DAMPER (120V POWER REQ.)
CEILING RADIATION DAMPER
-
4
SD
SD
SMOKE DETECTOR
0
T
THERMOSTAT
OS
S
SENSOR
R
REFRIGERANT LINES
-R-
- - -R.
- G-
G
NATURAL GAS LINES
- - -G
`vi
CEILING DIFFUSER (SUPPLY)
r
CEILING DIFFUSER (RETURN/EXHAUST)
3
EXHAUST FAN (CEILING MOUNTED)
[(53
INLINE FAN
lc,81
PROPELLER FAN
i
SIDEWALL DIFFUSER
+4--
DUCT FITTING
®
ZD
ZONE DAMPER
him
UNIT TAG
LI low. 0
I ‘4
111/
®
DUCT RISER
SEATTLE, WASHINGTON 98108
727 SOUTH KENYON
EVERGRL954R2
NOT PUBLISHED. ALL RIGHTS RESERVED. THE
DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS
AND ARRANGEMENTS REPRESENTED THEREBY
ARE AND SHALL REMAIN THE PROPERTY OF EVE-
RGREEN REFRIGERATION INC. NO PART THEREOF
SHALL BE REPRODUCED, COPIED, ADAPTED, DISC-
LOSED OR DISTRIBUTED TO OTHERS, SOLD, PUB-
LISHED OR OTHERWISE USED WITHOUT THE PRIOR
WRITTEN CONSENT OF AND APPROPRIATE COMPEN-
SATION TO EVERGREEN REFRIGERATION INC. VISUAL
CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC-
ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE
OF ACCEPTANCE OF THESE RESTRICTIONS.
4
'o
(V
'o
0
DESIGN DEVELOPMENT
bJ
0
ISSUED FOR CONSTRUCTION
AS BUILT DRAWINGS
❑ ❑
LULULEMON
HVAC COVER SHEET
J
2 co
ct co
F o0
zci)
W <C
I
O
NI -
REVISIONS
NO
DATE
ITEM
RECEIVED
CITY OF TUKWILA
JUN 3 0 2014
PERMIT CENTER
DWG. BY:
GN
CHK. BY:
GM/JS
JOB NO.:
514280
SHEET:
MI
L___
O
O
❑
22x22 UP TO
RELIEF HOOD
C11
1
7.5 TON
22x22 FA INTAKE UP TO
ROOF HOOD
OU
2
ON ROOF
\2
5 TON
REVIEWED FOR
CODE COIIIPLIANCE
APPROVED
!JUL 1 1 2014
City of Tukwila
BUILDING DIVISION
HVAC FLOOR PLAN
SCALE : 1/8" =1'-0"
RECEIVED
CITY OF TUKWILA
JUN 3 0 2014
PERMIT CENTER
FAX (206) 763 - 2389
(206) 763 - 1
EVERGRL954R2
NOT PUBLISHED. ALL RIGHTS RESERVED. THE
DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS
AND ARRANGEMENTS REPRESENTED THEREBY
ARE AND SHALL REMAIN THE PROPERTY OF EVE-
RGREEN REFRIGERATION INC. NO PART THEREOF
SHALL BE REPRODUCED, COPIED, ADAPTED, DISC-
LOSED OR DISTRIBUTED TO OTHERS, SOLD, PUB-
LISHED OR OTHERWISE USED WITHOUT THE PRIOR
WRITTEN CONSENT OF AND APPROPRIATE COMPEN-
SATION TO EVERGREEN REFRIGERATION INC. VISUAL
CONTACT WITH THE ABOVE DRAWINGS DR SPECIFIC-
ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE
OF ACCEPTANCE OF THESE RESTRICTIONS.
4
'O
N
'0
O
4
'O
N
'0
W W
DESIGN DEVELOPMENT
ISSUED FOR CONSTRUCTION
AS BUILT DRAWINGS
NO
LULULEMON
HVAC FLOOR PLAN
J
J
tX co
LLB T'
00
Z
rw <
~ J
O
)
CV I -
REVISIONS
ITEM
DATE
DWG. BY:
GN
CHK. BY:
GM/JS
JOB NO.:
SHEET:
514280