Permit M14-0137 - INTERURBAN OFFICE BUILDING A - ROOFTOP UNIT, HEATERS, FANS, DUCTWORK AND GRILLES/DIFFUSERS
INTERURBAN OFFICE BUILDING A 14550 INTERURBAN AVE S M14-0137 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 3365901605 14550 INTERURBAN AVE S Project Name: INTERURBAN OFFICE BUILDING A Permit Number: Issue Date: Permit Expires On: M14-0137 7/25/2014 1/21/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: SANFT LOUIE 6120 52ND AVE S , SEATTLE, WA, 98118 ALEX BURKHART 727 S KENYON ST , SEATTLE, WA, 98108 EVERGREEN REFRIGERATION LLC 727 S KENYON ST , SEATTLE, WA, 98108 Phone: (206) 763-1744 Phone: (206) 763-1744 EVERGRL954R2 Expiration Date: 1/6/2016 I DESCRIPTION OF WORK: INSTALLATION OF (1) ROOFTOP UNIT, (4) UNIT HEATERS, (1) ELECTRIC WALL HEATER, (2) SUPPLY FANS, (2) EXHAUST FANS, DUCTWORK, AND GRILLES/DIFFUSERS. Valuation of Work: $16,000.00 Type of Work: NEW Fuel type: GAS Fees Collected: $402.68 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Signature: Date: lJ I ILSIILI I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: (.4 it . ' Date: .7 (15 /(4 Print Name: % t ''Z This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 1800 0609 0705 0701 MECH EQUIP EFF MECHANICAL FINAL PIPE/DUCT INSULATION REFRIGERATION EQUIP ROUGH -IN MECHANICAL a separate permit issued by the City of Tukwila the job site at the time of inspection. CITY OF TUK 1 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** Site Address: 14 55 a vrZ'A - A v`e, 5 Ding Co Assessor's Tax No.: 3)6 54 5 0 Suite Number: Floor: Tenant Name: New Tenant: ❑ Yes ❑ ..No PROPER 1CY OWNZR Name: & KA vt Ve3,4'V 4.t."t' t t, . Address: q 1 Y2 Fo✓'°3 .tee, 5E City: / 35State: tiA Zip: a 2, Oc.i p CONTACT PERSON - person receiving all, project communication Name: l k n .i. N w rrt- Address: i`L7 5ty{-i, 17,,,nto,,, st- City: JCo ..bt.� State: j/ 4,_-)6-- Zip: q $iffy Phone:21-74 4 Fax: 2_06 -743 -2..3 s"i Email: ettu,Le eve, et\v.�C.Hhvncr4,04-, N CIE AN AL CONT.. Tt O Company Name: j.alAM Address: - E:7 5U kc,.,.o,l,, s-,t City: i State: Gill. Zip: / i 01 Phone: 2,0C, -'14 3 -- 1 Z -' Fax: 7,6 c., - 74 3 - 23 V1 Contr Reg No.: v.F.42. efayi SW IZ2 Exp Date: t / c / Tukwila Business License No.: p US _ 6+4 2 8 7.7 Valuation of project (contractor's bid price): $ j())v Describe the scope of work in detail: � � A"C.. () 1'w% '' Vim` ' 1,vo(�cwn5,+- (L) VI1� rt�✓St b (- (c) c(GU+— c Use: Residential: New ❑ Replacement ❑ Commercial: New [r Replacement ❑ Fuel Type: Electric ❑ Gas Other: H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace > l 00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm i Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser i Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: A" - Mailing Address: 12-7 So ✓tt kt vt°`n Set • Day Telephone: 5GA/1''t- City Date: % / A Li- wA- 16s' State Zip H:\Applcations\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS - '-'PernirtTR ACCOUNT 1 QUANTITY PAID 17;49072M L140657 16,,Ap,?1:: Ad d ress:14550INTE RU,R,Z7BAN 3'AVE '41,gn:13340,65,t9.,40;At160,45".,.,,,, .1.--,t',.A.,,,, 77128 ELECTRICAL $73.60., PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $73.60 TECHNOLOGY FEE $3.68 TECHNOLOGY FEE R000.322.900.04.00 0.00 $3.68 14.1:61i7"ITA'iaigi.:iW550 I4fi'iiVkiiAvri''A j :.,.,_9:,,..p6991o9,,,,92,.8 MECHANICAL ... ........r., ., . „, _ ., _ $387.1.9 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $277.25 PLAN CHECK FEE R000.322.102.00.00 0.00 $77.44 'TECHNOLOGY FEE' ,,,„:' ' - '`:1,:' ' --' :": '-' :-.-:" -; ' ' --:"!'"''-',-;' ..A ''':":4-r -*Z$15:49 TECHNOLOGY FEE R000.322.900.04.00 0.00 $15.49 IV l''. 4=Iii.i8: ';'Ad'le.SSE:14'59440AitiakiATAV'i'iq'-:''r2:3i6i'ioig.--i------42 A''W 4 4 d '',' Mg ''''' '% '..i---::?.. 7 ' ',:. - -r-- 233:88MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 0.00 $44.98 TECHNOLOGY FEE '1,141..''',.":"r''',-",74 -:'..?,: '',,,, -' '.-'"' " 'r' . J',,,., i . -drr. r,,, . , .r . , , ., r ..,,,, r,,,,, ,... r , ,, ,a,r- ,,,,,,,. .. . 9.00 TECHNOLOGY FEE R000.322.900.04.00 0.00 $9.00 M 14 0 Is 391a r Address: A. e5 /RrJERURBAN, AVES . „l'„,-„,..., 4 4,', ''...,,,/,.',WX4.1‘;‘,i-P4',3,`,"",,,,°6",,,r44.',..\-4,,€•*4M.1470,44.4 ',e4e: ARri:;3365901605, . ,Ii"44,74,041144%V.,W4e4.42,,, , - - 5$258:96, -, -i-1,,,: ' ,..-'; ,, -", ',',; '..t,'V,,,t7,0::tNit,-" ,c,--,q,,`,41o,m„:1,0 ,„, ,,„, ,, ,5' p ,,, 7 ,,,,,„ ,,, , ,,, N, r, , ,i,,,,,e ,,,,„, ,:,1,::,,,A „-,.«,,,.-s, ,,,,-,-'$14§ MECHANICAL 00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $166.70 PLAN CHECK FEE R000.322.102.00.00 0.00 $49.80 TECHNOLOGY FEE , „, „ , _$9.96 TECHNOLOGY FEE R000.322.900.04.00 0.00 $9.96 M14=0140 -t- 'Addreis-14520 INTERURBAN AVE S Apn: '3365901605=7- -:-.-- 71, :---.:, ,., , , ' 258:964-,, MECHANICAL . .. _ ., $249.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $166.70 PLAN CHECK FEE R000.322.102.00.00 0.00 $49.80 TECHNOLOGY FEE1_,... ,,., ' ' ; ....' ,.-... ; ,r,,- ,)1 1_6,, : T,, - .1 del.::;1P7,,,,A,;V, ,,,:414`..4. .::::4',. , i.,-;r: ::::: .::-V ' ?,'::- '',$9.96P TECHNOLOGY FEE R000.322.900.04.00 0.00 $9.96 Date Paid: Thursday, July 10, 2014 Paid By: EVERGREEN REFRIGERATION, LLC Pay Method: CHECK 006580 Printed: Thursday, July 10, 2014 12:39 PM 1 of 2 YS TEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PermitTRAK PAID $1,490.72 M14-0141 Address: 14510 INTERURBAN AVE S Apn: 3365901605 $258.96 MECHANICAL $249.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $166.70 PLAN CHECK FEE R000.322.102.00.00 0.00 $49.80 TECHNOLOGY FEE $9.96 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2566 R000.322.900.04.00 0.00 $9.96 $1,490.72 Date Paid: Thursday, July 10, 2014 Paid By: EVERGREEN REFRIGERATION, LLC Pay Method: CHECK 006580 Printed: Thursday, July 10, 2014 12:39 PM 2 of 2 SYSTEMS API- 0(37 ION NO. PERMIT NO. \ CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 INSPECTION RECORD Retain a copy with permit Project: A `Typrosp9ction: Lde( (Are; -945 ili ‘ 'el(-411 T ("CI I Address: 1 LO-1-0 M-efr-‘,0,--bcf,ok 4ve_5o. Date Called: Special Instructions: AM Date Wanted: 5-- 7-6 - ET a.m. p.m. Requester: hone No: Approved per applicable codes. Corrections required prior to approval. OMMENTS: ........E___ ins pector: r REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedute reinspection. INS ON NO. Retain a copy with permit INSPECTION RECORD /4(41- 6(37 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project Ild4r 1,9€4--- — 6(09 if -Type CInsperction:_, t , Fc Ki:1 ( Adds; Ires 1 5-TO -r-vciWt 1 1 f i I 9 q k 4 VS Dat Called: 1 r Special Instructions: AM Daternt114 _ is_ a.m. P-rn- Reouver: 7 to G4,‘ Phone No: 1 LJApproved per applicable codes. •Corrections required prior to approval. COMMENTS: `5. rre V Ve.- Z 1,(,uK kfT o ve.. t kfir veij&ijico Ne-Pct-- Wore-4 la eA etf pcio(g e uhrt-tt reffrtso e6A-cv-t.1 rctlA CAC( tCv. r-e-t tVcrj tkt?c-tttliVVLr-34' "Fvf Inspector: re Date: (5. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 0ION111 Retain a copy with permit INSPECTION RECORD NO. PERMIT NO. /Put,/ -ct (37 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: (ARI6EOPte(3 e-•- Type cg Inspection: Ko wi k—X4A -Ate-CIA 'Address: 314.53--0 .7-Kitirwritt4 AvQ4), Date Calle& Special Instructions: vAA IMdy A- cf-C,e4 Date Ite • 0 ...,( j_. a.m. P.m. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. C • MENTS: yrn 4,5*ht 2_Pek tr tv\Alk\c- ikk- s L Date,3 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Summary MEM-I-SUM Revised June 2013 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Project Info FILE COPY "mit No. Project Address 14550 Interurban Ave s Date 7/7/2014 Tukwila, WA 98188 For Building Dept. Use Applicant Name: Alex Burkhart Applicant Address: 727 South Kenyon St. Seattle, WA 98108 Applicant Phone: 206-763-1744 ext. 247 Project Briefly system Description describe mechanical type and features. Includes Plans Installation of one (1) rooftop unit, ten (10) unit heaters, five (5) electric wall heaters, three (3) supply fans, and two (2) exhaust fans. Drawings must contain notes requiring compliance with commissioning provisions per Section C408 Compliance Option ® Simple System 0 Complex System 0 Systems Analysis Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu/h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exceptions Heat Recovery Y/N RTU-1 Lennox KGA060B2DM 59000 400 13 N/A Econmizer N Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu/h OSA cfm or Econo? Input Btuh Output Btuh Efficiency4 Heat Recovery Y/N RTU-1 Lennox KGA060B2DM 52000 400 65000 52000 80 N UH-1, 2 Reznor UDAP 75 63000 N/A 75000 63000 84 N vs-3 Reznor UDAP 60 49800 N/A 6000.0 49800 83 N vB-4 Reznor UDAP 30 24600 N/A 30000 24600 82 N EWE-1 King PAW1215 N/A N/A N/A N/A N/A N Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 CFM SP1 HP/BHP Flow Controls Location of Service SF-1 Greenheck AS-12-433-A4 651 0.25" 0.25 Cv Roof SF-2 Greenheck AS-12-433-A4 605 0.25" 0.25 Cv Roof EF-1 Broan QTR110 90 0.20" 0.05 Cv Ceiling EF-2 Broan QTR110 90 0.20" 0.05 Cv Ceiling Service Water Heating EgtapdRl OR Equip. ID Equip Type Brand Name' CODE CA OPL! MncialJ�aOVE ��'✓ Sub- Category EF7 RE(;EIVED QJ oQ iJKWILA IA2 20 4 JUL 10 2014 PERMIT CENTER 1 If available. 2 As tested according to applicable. 5 Flow control types: varia mroCA .2.3(8 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as )DiViaoridl (CV), or variable speed (VS). 6 Econr exception number per AAI4-oi';i „Mechanical Permit Plans Checklist - Page 1 of 3 MECH-CHK 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Address 14550 Interurban Ave S Date 7/7/2014 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes GENERAL PROVISIONS Equipment Sizing & Performance Yes C403.2.1 Load calculations Load calculations performed per ASHRAE Std 183 or equivalent per Chapter 3 M 1 Yes C403.2.2 Equipment and system sizing Output capacity of heating and cooling equipment and systems do not exceed calculated loads, note exceptions taken M 1 Yes .. C40325 Minimum ventilation Ventilation (natural or mechanical) provided per IMC; indicate mechanical ventilation is capable of being reduced to minimum requirement per IMC M1 Yes C403.2.3 & C403.2.3.2 &effiiency C403.2.12.1 Equipment minimum c Provide equipment schedules or complete MECH-SUM tables with type, capacity, efficiency, test standard (or other efficiency source) for all mechanical equipment M1 N/A C403.2.13 Electric motor efficiency Provide equipment schedule with hp, rpm, efficiency for all motors; note except. N/A C403.2.10 m Fan power limitation Fan system motor hp or bhp does not exceed limits per Table C403.2.10.1(1) N/A C403.2.10.3 & C403.2.13 Fractional hp fan motors Indicate fan motors 1/12 to 1 hp are ECM type or meet minimum efficiency req. N/A C403.2.3 capacity Maximum air cooled chiller Indicate air-cooled chiller capacity does not exceed air-cooled chiller limit N/A C403.2.1 Non-standard water-cooled chillers Full -load and NPLV values for water-cooled centrifugal chiller adjusted for non-standard operational conditions N/A C403.2.12.1.2 Centrifugal fan cooling towers Large capacity cooling towers with centrifugal fan(s) meet efficiency requirements for axial fan open circuit cooling towers N/A C403.2.3 Forced air furnace and unit heaters Indicate intermittent ignition or IID, flue/draft damper & jacket loss N/A C403.2.3.3 heating/cooling equipment Packaged electric List equipment required to be heat pumps on schedule N/A C403.2.3.4 Humidification Indicate method of humidification (note requirements for systems with economizer) HVAC System Controls & Criteria Yes C403.2.4.1 Thermostatic controls Indicate locations of thermostatic control zones on plans, including perimeter systems M1 Yes C403.2.4.1.1 Heat pump supplementary heat Indicate staged heating (compression/supplemental) & outdoor lock -out temp M1 Yescooling C403.2.4.2 Setpoint overlap (deadband) Indicate 5°F deadband minimum for systems controlling both heating & M1 Yes C403.2.4.3 Automatic setback and shutdown Indicate zone t-stat controls with required automatic setback & manual override M 1 Yes C403.2.4.3.3 Automatic (optimum) start Indicate system controls that adjust equip start time to match load conditions M1 Yes C402.4.5.2 &Dampers C403.2.4.4 Indicate location of OSA, exhaust, relief and return air dampers; include AMCA rated leakage and control type (motorized or gravity; note exceptions M1 Yes C403.2.11 Heating outside a building Indicate radiant heat system and occupancy controls M 1 N/A C403.2.4.5 Snow melt systems Indicate shut-off controls based on outdoor conditions N/A C403.2.4.6 Combustion heating i equpment Indicate modulating or staged control N/A C403.2.4.7 Group R1 hotel/motel systems Indicate method for guest room automatic setback & set-up of 5°F minimum N/A C403.2.4.8 / g Group R2/R3 dwelling unit systems Indicate 5-2 programmable thermostats in primary spaces with minimum of two setback periods; note exceptions taken Yes C403.2.5.1 ventilation Demand controlled Indicate high -occupancy spaces and systems requiring DCV M1 Yes C403.2.5.2 Occupancy sensors Indicate spaces requiring occupancy -based system control and method; or altemate means provided to automatically reduce OSA when partially M 1 Yes C403.2.5.3 Enclosed loading dock/parking garage ventilation Indicate enclosed loading dock and enclosed parking garage ventilation system activation and control method M 1 N/A C403.2.5.4.1 Kitchen exhaust hoods Indicate kitchen hoods requiring make-up air; indicate make-up air source and conditioning method N/A C403.2.5.4.2 Laboratory exhaust systems Indicate lab exhaust systems requiring heat recovery, method & efficiency; or alternative method taken (VAV, semi -conditioned makeup, or CERM calculation) N/A C403.2.6.1 Energy recovery - ventilation systems Indicate ventilation systems requiring ER, method & efficiency; note exceptions N/A C403.2.6.2 Energy recovery - condensate systems Indicate on -site steam heating systems requiring energy recovery N/A C403.2.6.3 Energy recovery - condenser systems Indicate remote refrig. condensers requiring ER and use of captured energy Mechanical Permit Plans Checklist - Page 2 of 3 2012 Washington State Energy Code Comp for Commercial, Group R1, and > 3 story R2 and R3 MECH-CHK Revised June 2013 Project Address 14550 Interurban Ave S Date 7/7/2014 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes GENERAL PROVISIONS, CONTINUED HVAC System Controls & Criteria, Continued N/A C403.2.12 Variable flow control - fans/pumps Indicate fan & pump motors requiring VF control & method (VSD or equiv controls) N/A C403.2.12.1 oo clfcontrol- ling towweers coong Indicate cooling tower fans requiring variable flow control and method N/A C403.2.12.2 Large volume fan systems Indicate fan systems requiring airflow reduction based on heating and cooling demand; or exception taken N/A C403.2.12.2 Single zone AC systems Indicate method of cooling demand -based fan control for sys. > 110,000 btuh N A / C403.2.4.10 DDC system capabilities Identify all DDC system input/output control points and indicate capability for trendina and demand response setooint adiustment Ducting Systems Yes C403.2.7.1 &Duct C403.2.7.3 construction Indicate all ductwork constructed and sealed per IMC, C402 leakage requirements and IBC vapor retarder requirements M1 N/A 403.2.7.3.1-; Duct pressure classifications Identify location of low, medium and high pressure ductwork on plans N/A C403.2.7.3.3 High pressure duct leakage test Indicate high pressure duct leakage testing requirements on plans; provide test results to jurisdiction when completed Yes C403.2.7.1 / 2 Duct insulation Indicate R-value of insulation on ductwork M 1 Piping Systems N/A C403.2.8 Piping insulation Indicate R-value of insulation on piping N/A C403.2.8.1 Piping insulation exposed to weather Indicate method of protection from damage/degredation SIMPLE SYSTEMS Qualifying Systems Yes C403.3 Qualifying single zone systems Verify unitary or packaged equipment does not exceed capacity limits, does not have active humidifcation or simultaneous heating/cooling M1 N/A C403.3 systems Qualifying 2-pipe heating Verify 2-pipe heating -only system does not exceed capacity limits N/A C403.3.2 Hydronic system controls Refer to Complex Systems Section C403.4.3 Simple System Economizers Yes C403.3.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip sched. M 1 Yes C403.3.1.1.1 Air economizer capacity Indicate modulating OSA control capability up to 100% OSA, or exception M 1 Yes C403.3.1.1.3 Air economizer high limit controls Indicate high limit shut-off control method per Table C403.3.1.1.3(2) M 1 Yes C403.1.1.2 Integrated air economizer operation Indicate capability for partial air economizer operation for systems with capacity > 65,000 btuh M 1 Yes C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exception(s) M 1 COMPLEX SYSTEMS Complex System Economizers Yes C403.4.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip sched. M 1 Yes C403.4.1.4 Economizer heating system impact Verify control method of HVAC systems with economizers does not increase building heating energy usage during normal operation M 1 Yes C403.4.1.3 Integrated economizer operation Indicate capability for partial economizer operation for air or water econo systems M 1 N/A Moved Water economizer capacity Indicate water econo capable of 100% cooling capacity at 50°F db/45°F wb OSA N/A C403.4.1.2 Water economizer maximum pressure drop Indicate precooling coils and heat exchangers do not exceed pressure drop limit N/A C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exception(s) Mechanical Permit Plans Checklist - Page 3 of 3 MECH-CHK Revised June 2013 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Project Address 14550 Interurban Ave S Date 7/7/2014 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes COMPLEX SYSTEMS, CONTINUED Specific System Requirements N/A C403.4.2 2 c403.2.1 Variable flow control - fans Indicate fans requiring variable flow control and method N/A C403.4.2.1 VAV fan static pressure sensors Indicate sensor locations on plans; include at least one sensor per major duct branch N/A C403.4.2.2 VAV fan static pressure setpoint Indicate fan system static pressure setpoint based on zone requiring most pressure N/A C403.4.5 VAV systems serving multi- zones Indicate supply air systems serving multiple zones that are required to be VAV, method of primary air control, and zones served; note exceptions taken N A / C403.4.5.4 VAV system supply air reset Indicate controls that automatically reset supply air temp in response to loads N/A C403.4 Large capacity cooling systems Indicate method of multi -stage or variable control for building cooling system capacity > 300 tons N/A C403.4.7 Hot gas bypass limitation Indicate cooling equipment unloading or capacity modulation method N/A C403.4.3 systems Large capacity boiler Indicate multi -stage or modulating burner for single boilers > 500,000 btuh N/A C403.4.3 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers N/A C403.4.3.5 Chiller / boiler plant pump isolation Indicate capability to automatically reduce overall plant flow and shut-off flow through chillers & boilers when not in use N/A C403.4.2 & C403.4.3.6 Variable flow control - pumps Indicate pumps requiring variable flow control S, method N/A C404 & C403.4.4 03.4.4 Variable flowcontrol cooling towers Indicate cooling tower fans requiring variable flow control and method N/A C403.4.3.4 Hydronic system part load controls Indicate heating & chilled water systems have the capability to automatically reset supply water temp AND reduce flow by >_ 50 % for systems > 300,000 N/A C403.4.3.2 Two -pipe changeover systems Indicate deadband, heating/cooling mode scheduling and changeover temperature range N/A C403.4.3.3.1 Water loop heat pump - deadband Indicate capability of central equipment to provide min. 20°F water supply temp deadband between heat rejection and heat addition modes N/A C403.4.3.3 Water loop heat pump - heat rejection Provide heat exchanger that separates cooling tower and heat pump loop in Climate Zone 5 N/A C403.4.3.3.3 Water loop heat pump - isolation Indicate 2-way isolation valve on each heat pump and variable flow control for systems with total pump power > 10 hp N/A C403.4.6 recovery Condenser water heat Indicate system provided to pre -heat service water and efficiency N/A C403.5 Cooler / freezer - anti -sweat heaters Indicate w/sf & control method for walk-in cooler/freezer door anti -sweat heaters N/A C403.5 / 6 Cooler / freezer -evaporator and condenser fans Indicate motor type for evaporator and condenser fans < 1 hp SERVICE WATER HEATING Service Wa er Systems N/A C404.2 Water -heating equip min. efficiency Provide equipment schedule or complete MECH-SUM table with type, capacity, efficiency, test standard (or other efficiency source) N/A C404.3 Temperature controls Indicate temperature controls have required setpoint capability N/A C404.4 Heat traps Indicate piping connected to equipment have heat traps on supply & discharge N/A C404.5 Insulation under water heater Indicate R-10 insulation under tank N/A C404.6 Service water piping insulation Indicate R-value of insulation on piping; note exceptions taken N/A C404.7 / g Circulation systems and heat trace shut-off Indicate shut-off capability based on occupancy and periods of limited demand N/A C404.9 Group R-2 service hot water meters Indicate method of usage metering for dwell. units served by central HW system Pools & In -Ground Permanently Installed Spas NA / C404.10.1 Pool heating equip min. efficiency Provide equipment schedule or complete MECH-SUM table with type, capacity, efficiency, test standard (or other eff. source); heat pump heaters >_ 4 COP N/A C404.10.1 / 2 Pool heater on / off controls Indicate automatic on/off control based on scheduling & accessible on/off switch on heater that operates independent of thermostat setting; or N/A C404.10.3 Pool covers Indicate vapor retardant cover and insulation rating as required N/A C404.10.3 Pool assembly insulation Indicate rating of insulation on sides and bottom of pools heated to > 90°F N/A C404.10.4 Heat recovery Indicate method, exhaust air temperature reduction and recovered energy use ANN AM SHUTLER ®■ CONSULTING ® ENGINEERS Inc. 12503 Bel —Red Road, Suite 100 Bellevue, Washington 98005 (425)450-4075 FAX: (425)450-4076 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 2 2014 City of Tukwila BUILDING DIVISION - 30K280/170 4.5x3xY4 28G4N7.9K'\ 14K280/170 JOB INTERURBAN OFFICE WAREHOUSE BLDG—A Tukwila, Washington SHEET NO SKS-1 CALCULATED BY JS OF DATE 7-2-14 SCALE NOTED Job No. 14-01.29 FILE COPY Permit No. L.L.V. N N x SKS-2 D/SKS-3 44x3 W1 16K280/170 L.L.V. 2x26 W12x26 or- D/SKS-3 B/SKS-2 N N x J M1Or?1 RTU MAX. 1000# 16K280/170 W14x22"\ ECEIVED CIT OF TUKWULA UL 10 2014� PE MIT CEN1' R PARTIAL ROOF FRAMING PLAN SCALE: M —, —p. SHUTLER MEI ■ CONSULTING Mil ENGINEERS Inc. 12503 Bel -Red Road, Suite 100 Bellevue, Washington 98005 (425)450-4075 FAX: (425)450-4076 INSULATION PER ARCH. 11/2"TYPE'B' ROOF DECK JOIST PER PLAN #12 SCREW 12"o.c. ALL SIDES JOB INTERURBAN OFFICE WAREHOUSE BLDG.—A Tukwila, Washington SHEET No SKS-2 OF CALCULATED BY JS DATE 7-2-14 SCALE NOTED Job No. 14-01.29 HVAC UNIT & CURB PER MECHANICAL DRAWINGS zc.5x3x0/4 L.L.V. 74.4x3xY4 L.L.V. S LE: 3/4 ECT1 -0I.O,N A/SKS-2 SCA= STEEL DECK PER PLAN 3/16 JOIST PER PLAN (BEYOND) TYP. 4x3xY4 L.L.V. JOIST GIRDER PER PLAN SECTION,B/SKS-2 SCALE: Y4 =1 —0 JOIST PER PLAN II I I 24.5x3xY4 HVAC II SUPPORT I 500# MAX. REACTION �-- PROVIDE ADDITIONAL WEB PER JOIST MFR REQUIREMENTS SECTION C/SKS-2 SHUTLER CONSULTING ENGINEERS Inc. 12503 Bel —Red Road, Suite 100 Bellevue, Washington 98005 (425)450-4075 FAX: (425)450-4076 PREMANUFACTURED CURB BY HVAC CONTRACTOR #12 SCREW 12"o.c. ALL SIDES OF HVAC UNIT g, Model, 7/3/2014 6: JOB INTERURBAN OFFICE WAREHOUSE BLDG.—A Tukwila, Washington SHEET NO SKS-3 OF CALCULATED BY JS DATE 7-2-14 SCALE NOTED Job No. 14-01.29 HVAC UNIT PER MECHANICAL DRAWINGS 45x3xY4 L.L.V. STEEL BEAM PER PLAN SECTION D/SKS-3 ®® SHUTLER CONSULTING ENGINEERS, INC. JOB Bldq A, Interurban Office SHEET NO. COVER OF CALCULATED BY JJS DATE 7/1/2014 12503 Bel -Red Road, Suite 100 CHECKED BY DATE Bellevue, Washington 98005 SCALE (425) 450-4075 FAX (425) 450-4076 JOB NUMBER 14-01.29 STRUCTURAL CALCULATIONS FOR: BUILDING A - INTERURBAN OFFICE/WAREHOUSE 14600 INTERURBAN AVE S TUKWILA, WASHINGTON PROPOSED BY: A & B PROPERTIES 6120 52ND AVENUE SOUTH SEATTLE, WASHINGTON 98118 ARCHITECT: N/A DESIGN CRITERIA: CODE INTERNATIONAL BUILDING CODE, 2012 Edition ROOF LIVE LOAD25 PSF (SNOW LOAD) WIND LOAD 110 MPH, EXPOSURE `B" SEISMIC DESIGN INFORMATION: Ss = 144.0 % SDs = 0.87 Sl = 49.0 % SDI = 0.79 ap = 2.5 Rp = 6.0 Ip = 1.0 SITE SOIL CLASS "E" SEISMIC DESIGN CATEGORY = "D" • VIM SH UTLER CONSULTING ENGINEERS, INC 12503 Bel -Red Rd., Suite 100 Bellevue, WA 98005 (425) 450-4075 FAX (425) 450-4076 JOB /°Y SHEET NO J 'r CALCULATED BY J J DATE o f f ice, /117a- douse 7-/ SCALE SHUTLER _ - CONSULTING ENGINEERS, INC 12503 Bel -Red Rd., Suite 100 Bellevue, WA 98005 (425) 450-4075 FAX (425) 450-4076 JOB rg>u)Z U12bi3,✓ SHEET NO 5 -a CALCULATED BY V J DATE 74- /t-i OF SCALE ® SHUTLER JOB Interurban Office Warehouse • ®® 1 CONSULTING SHEET No. 4' S -I OF ®/ ®® ENGINEERS, INC. CALCULATED BY JJS 12503 BEL-RED ROAD, Suite 100 Bellevue, WA 98005 (425) 450-4075 -- FAX (425) 450-4076 DATE 7-1-14 SCALE Roof Dead Load Tabulation Decking Joist Girder Uplift Roofing 0.30 PSF 0.30 PSF 0.30 PSF 0.30 PSF Insulation 1.44 PSF 1.44 PSF 1.44 PSF 1.00 PSF Protection board 2.00 PSF 2.00 PSF 2.00 PSF 2.00 PSF Decking 2.90 PSF 2.90 PSF 2.90 PSF 1.90 PSF Sprinkler N/A PSF 2.50 PSF 2.50 PSF 1.00 PSF Ceiling 1.80 PSF 1.80 PSF 1.80 PSF 1.80 PSF Electrical N/A PSF 0.56 PSF 0.56 PSF 0.25 PSF Bar Joist N/A PSF 2.00 PSF 2.00 PSF 1.80 PSF Mechanical N/A PSF 1.50 PSF 1.50 PSF 0.25 PSF Girder N/A PSF N/A PSF 2.00 PSF 0.00 PSF Colateral * 0.90 PSF 0.00 PSF 0.00 PSF 0.00 PSF Total 9.34 PSF 15.00 PSF 17.00 PSF 10.30 PSF *Colateral Toad is intended for suspended items such as head walls, interior signage, etc. (use in retail) Rigid insulation 0.24 PSF .per inch, R-5.6 per inch, using 6.00 inches equals R 33.6 TPO roofing, 60mi1 membrane - 0.30 PSF, 45 Mil membrane - 0.21 PSF DensDeck protection board, 1/4" thick - 1:20 PSF, 1/2" thick - 2.00 PSF, 5/8" thick - 2.50 PSF ROOF LIVE LOAD 25 PSF SNOW LOAD SHUTLER ®® CONSULTING ®® ENGINEERS, INC. 12503 Bel -Red Road, Suite 100 Bellevue, WA 98005 (425) 450-4075 * FAX (425) 450-4076 JOB /i%rZu/t-Pd SHEET No. CALCULATED BY S- OF DATE 7 SCALE Unit data: Unit base weight Economize Curb Total weight Weight used in calculations Wind and Seismic forces on HVAC Unit 746 lbs. 0 lbs. 100 lbs. 846 lbs. Unit Dimensions Height = Length = Width = 1000 lbs., to include duct work, etc. Seismic: Fp =(0.4*ap*SDS*Wp)*(1+2*(z/h))/(Rp/Ip) Fp = 435 lbs. <== Controls Fp(max) = 1.6*Sps*Ip*Wp Fp(max) = 1392 lbs. Fp(min) = 0.3*Sps*Ip*Wp Fp(min) = 261 Ibs Fp = 304.50 Ibs. (ASD) 36.4 in. 83.3 in. 47 in. Wp = 1000 lbs. SDS = 0.870 ap = 2.5 Rp = 6.0 Ip = 1.0 z = h => z/h = Wind: (Section 29-5.1 of ASCE 7-10) Fh = qn*(GCf)*Af (Horizontal Force) F„ = qn*(GCr)*Ar (Vertical Uplift Force) qh = 0.00256*KZ*KZ,*Kd*V` = Fn = 35.02 *Af PSF F„ = 27.65 *Ar PSF Fh = Fh = F„ = MOT = MOT = MOT = 18.43 PSF 612.58 Ibs.(Transverse Horizontal Force) ASD 345.63 Ibs.(Longitudinal Horizontal Force) ASD 450.99 Ibs.(Vertical Uplift Force) ASD 11652.20 in.-Ibs. (Seismic) 15436.92 in.-Ibs. (Wind - Transverse) 8709.91 in.-Ibs. (Wind - Longitudinal) Load combinations: Case 10.60 Dead + 0.6 Wind Case II 0.60 Dead + 0.7 Seismic Transverse Seismic Hold Down Force =-35.17727 lbs Longitudinal Seismic Hold Down Force =-154.35 Ibs Transverse Wind Hold Down Force = 276.33 Ibs Longitudinal Wind Hold Down Force = 34.37 lbs File:HVAC wind seismic.xls, modified 2-21-14 1.00 Curb Dimensions Height = 14 in. Length = 80 in. Width = 44 in. Basic Wind Speed 110 MPH Exposure B Average roof height 27.50 ft. KZ = 0.700 Table 30.3-1 Kd = 0.85 Table 26.6-1 KZf = 1.0 Section 26.8.2 (GCr) = Horizontal Gust Factor = (GCr) = Vert Uplift Gust Factor = Af = Vert Proj Area (Transvese) = Af = Vert Proj Area (Longitudinal) _ Ar = Horizontal Projected Area = Hold down NOT req'd Hold down NOT req'd UPLIFT UPLIFT 1.9 1.5 29.16 ft' 16.45 ft` 27.19 ft< )i b Roofing Systems 1. Product Name GenFlex Heat -Welded Reinforced Membrane TPO 2. Manufacturer GenFlex Roofing Systems 250 W. 961h Street, Suite 150 Indianapolis, IN 46260 Toll Free: 800-443-4272 Fax: 317-853-4602 Email: TechnicalServicesGenFlex.com www.genftex.com 3. Product Description BASIC USE GenFlex TPO is a reinforced thermoplastic polyolefin roofing membrane designed for use on commerciol, industrial and insti- tutionol buildings. The TPO compound is resistant to a wide variety of common -noftop contaminants and is highly ozone -)t. Heat welded seams ore strong n- _ontinuous. Additional system components in- clude insulation, plates, fasteners, adhe- sive, sealont, coated metal, flashing, and applicable roof -top accessories. GenFlex requires components to be products of GenFlex Roofing Systems. The GenFlex TPO system may be in- stolled as o 8ollosted. Mechonicolly At- tached or Fully -Adhered design for either new or reroof applications. COMPOSITION & iv1ATERIAL S Fused; non -halogenated thermoplastic scrim -reinforced polyolefin membrane plasticizer -free ethylene propylene rub- ber (EPR) based, Two layers of TPO are fused with on inner toyer of polyester rein- forcerner,t.during the manufacturing pro- cess. COLOR ChorCool Black, White or Grey SIZE GenFlex TPO is ovoitoble in 74" (1,9 m), 8' (2.4m), 10' (3.0m) and 12.3' (3.6rn) ".side by.. 100' (30,5 m) long. GenFlex TPO is avail- --He in two thicknesses, 45 and 60 mil (1.1 m). i 5 -> Thermoplastic Membrane Rooting 7540 A HT, • 45 mil membrane - .21 psf (1.1 • 60 mil membrane - .30 psf (1.6 • Bollost - Minimum 10 psf (48.8 additional where required INSTALLATION SYSTEMS Ballasted System - Economical a installation on structures able to system weight. Maximum slope is Insulation and membrone ore too with membrane fastened at peri Seams are adhered using GenFl proved heat welding equipmen Proved ballast is smooth, roun washed river rock 3/4" - 1 1/2" (19 mm) in diameter. Fully Adhered System - Installs q with no mechanical penetration membrane. Smooth appearing system is particularly useful where roof surface is visible. Seams are welded using GenFlex approved heat welding equipment. Medhonicolly Attached Seam System - GenFlex plotes layout marks and fastened of a spac determined by local buildin Seams ore welded usingg codes. op - proved heat -welding GenFlex equipment. LIMITATIONS See Part 7. Warranty, for additional war- ranty limitations. • GenFlex TPO must be installed under environmental conditions specified by the manufacturer. • The system may only be instc lled over GenFlex-approved substrates • Only compatible materials furnished or approved by GenFlex may be used. • The system must be installed in accor- dance with the GenFlex TPO Specifco- tions Manual. • GenFlex TPO-may only be installed by GenFlex authorized contractors C .,. enFlex Roofing Systems for membrane compatibility with acids, animal Pots, grease, chemicals, solvents and oils. 4. Technical Data APPLICABLE STANDARDS American Society for Testing & Moterials (ASTfv1) • ASTM D570- Water Absorption ofPlos- tics GenFlex Roofing Systems kg/m, • ASTM 0471 - Rubber Properly Effect of ) Liquids kg/m 2) • ASTM 0573 - Deteriorofion in Air Oven kg/m 2); • ASTM D638 - Tensile Properties of Plastics • ASTM D751 - Test Methods for cocked fabrics nd fast • ASTM D1149 - Rubber Deteric;otion - support Surfoce Ozone Crocking in c Chomber 2 in 12. 'ASTM D 1204 - Linear Dimensional se laid •Chonges o/ Nonrigid Thermoplastic meter. Sheeting or Film at Elevated Tempera- ture ex op- • ASTM D21.36 - Coated Fabrics - Low- t. Ap- Temperature Bend Test dad, ASTM•D2 565peratin 9- Operating Xenon , - 38 Type Light-ExposApparatus rc- Without Wale for Exposreof Pl✓ast csd uickly • ASTM D3045 - Heat Aging of Plastics of the Without Load • ASTM E96 - Water Vopor Transmission of Materials ASTM G21 - Determining Resis/once of Synthetic Polymeric Materiels 10 Fungi led • ASTM G 155 - Xeon Arc Light Apparatus for Exposure of Non -Metallic Materiels ing ASTM G 151- Exposing Non -Metallic Ma- teriels in Accelerated Test Devices that use Laboratory Light Sources PHYSICAL/CHEIVICIAL PROPERTIES Refer to Toble 1 for test properties. APPROVALS Status of approvals varies with roof con- struction used. The following and other agencies will provide approvals on Gen - Flex TPO systems. See agency publica Lions and manufacturer 's literature: • Building Officials and Code Adminislro tors International (BOCA) • Factory Mutual - 1-60, 1-90 wind uplift clossificotions • International Conference of Building Of- ficials (IC80) • Metropolitan Dade County, Florida ° Southern Building Code Congress Inter- national (SBCCI) • Underwriters Laboratories Inc. - Classifi- cation, hourly rating 5. Installation PREPARATORY WORK The dead load capacity of the deck and supporting structure must he sufficient to support the load of the system The deck 3riGGAIA`cnd ldnf:G. ol,h_Consl:oc lion A.endMAnUInEicdeoe iepis,e,edl'PCemorin U The Consnucilcn Specihcolicns In;liJWe 1he!en pod 5p and is used o-:ilh !heir permhsion. the monulnclurr's responsinle ro, Iechrsiccl cc o,mcl conlo,ms so the edit ;; ,style P CC.GAIh 1 R.•socY. =199d /uthileci; /i,l Source, h1; Ri0^I! Msrrved. J7540 Thermoplastic Membrane Roofing Doling Systems lust be designed and constructed topro- ide the removel of all voter within 48 ours ofler o rainfall. Substrate must be noolh, level and clean. All grovel on xisling roofs roust be removed. JSULATION INSTALLATION .sulation fostening rnust be to Gen - ex Roofing Systems specifications ;EMBRANE INSTALLATION )sition GenFlex TPO membrane over op- oved substrote. Position membrane so at the top sheet edge is in alignment ih the premarked lines on the bottom eel. Allow membrone to relox approxi- afe!y 1/2 hour prior to any welding, al- chment, or flashing, ASHINGS & ATTACHMENTS Loch the membrane of roof perimeter, rb flashing, skylight, expansion joint and 7- )f penetrotion using standard GenFlex Ge Details. GenFlex TPO walkway pods Ge required at all high traffic points, such a G roof top units, hatches, access doors, be d roof top ladders. Ge ing for w are 3LE 1 PHYSICAL PROPERTIES OF GENFLEX TPO MEMBRANE sical Properties Thickness, nominal, ASTM D751 Breaking Strength. min. ASTM D751 Elongation, Ultimate, %, ASTM D412 Tearing Strength, min., ASTM D751 3ritlleness Point, max,, ASTM D2137 Dzone Resistance, no crocks, AST1vi Dl 149 Voter obsorpfion, max., ASTivl D471 ?flies After Heat Aging ASTM D573 reoking Strength, min., ASTM D751 coring Strength, min.. ASTM D7.51 near Dimensional Change, ASTM D1204 eaiher resistance ASTM G26, G53 nmaqua, ASTM E838 lies offer Weotherino "king Strength ASTM D751 'arced, ASTM D751 METHODS OF ATTACHMENT GenFlex TPO may be Mechanically At- tached, Fully Adhered or Ballasted. Me- chanically Attached Systems must be ol- toched with GenFlex Seam Ploles and GenFlex Fasteners along the entire length of each seam. Additional oltochment is required at perimeters and corners. 6. Availability & Cost AVAILABILITY Available nationwide through c network of distributors and agents, for sole to ou- thorized GenFlex Roofing Systems appli- cators. COST For cost information, contact the nearest distributor or agent, or contact GenFlex. Warranty nFlex projects must be inspected by o nFlex representative to be eligible for enFlex warranty. Components must supplied by GenFlex. Warranty covers nFlex-supplled materials only. Meet - the limitations in Part 3 is a condition arranty approval. Somple worronties available upon request. Specification fTo4so (1.1 mm) .060" (1.5 mm) 225 Ip f (1.0kN) 500 55 1pf (245N) -40°F (-40°C) Pass ±4% 225 Ipf (1.0kN) 55 1pf (245N) ± 2% Pass 225 1pf (1.0kN) 70 Typical Volues ± 10% ± 10% 330 1pf (l.5kN) Typ, 500 156 1pf (694N) -49°F (-45°C) Pass ± .1% 330 lot (1.kN) Typ. 156 1pf (694N) >1% Pass 3,000,000 Longleys 330 1pf (1.5kN) Typ, 97 8. Maintenance Periodic inspection of the roof system and cleaning of drains is recommended to allow proper water run-off, avoiding over- loading roof with ponded woter. Regular cleaning must be done in areas where contaminants potentially harmful to the roof system may accumulate, e.g„ oil, grease, freon, acids, solvents. Inform all tradespeople servicing the roof equip- ment that it is a single -ply roof and that they must proceed accordingly, Contact GenFlex Roofing Systems in writing for op- provol before making alterations on, ad- jacent to, or through the roof system. 9. Technical Services GenFlex technical personnel ore avoil- oble in-house to answer telephone ques- tions or approve details by mail, fax or e- mail. The GenFlex TPO Specifications Manual is available upon request for specifiers and roofing contractors. 10. Filing Systems • Architects' First Source for Products • Sweet's Catalog Files ▪ SweetSource • Additional product information is avail- oble from the manufacturer. SFiC-LnlA=on01.WNUSPkC=ae repislomtl Iratlsn lurks o1 The Can_I,uci;on 5pscifcofions Infhlule. the I°n wl5 - ol me Can FEE. ion SpecicoSons Instils,le aondtegi leis wills the;, , _�---mil tlyie fe.-:clan The moneloc'uiel ;s iespons; a Iw I V OCY ) I9rmol cenlwms to Ina editorial U�le oc^;.;ol'Jc[',,rOC'/. `1996 ArC1�:'eels'li�!I Sw,t:C. All (ii,-,113 ire:Cfeetl. Georgia-Pacific Manufacturer Georgia-Pacific Gypsum LLC 133 Peachtree Street Atlanta, GA 30303 Georgia-Pacific Canada LP 7070 Mississauga Road, Unit 120 Mssi Technical Service Hotline: 1.000-225.5119ss auga, ON L5M 7V9 Description DensDeck° Roof Board is an exceptional fire barrier, thermal barrier, coverboard and recovery board used in various commercial roofing systems. The DensDeck Roof Board design employs fiberglass mats front and back that are mechanically bonded to a high density gypsum core, providing excellent lire resistance and wind uplift properties. The unique construction of DensDeck Roof Board provides superior flute spanning that stiffens and provides increased foot traffic resistance to the roof deck. Additionally, DensDeck Roof Board has been shown to withstand delamination, deterioration and job -site damage far more effectively than roofing membrane substrates such as paperfaced gypsum board, fiberboard and perlite insulation. DensDeck Roof Board is highly resistant to the growth of mold when tested, as manufactured, per ASTM D 3273. Primary Uses Roof system manufacturers and designers have found DensDeck Roof Board to be compatible with many types of roofing systems, including: built-up, modified bitumen, single ply, metal systems, wood shingle and shake, tile, slate, as well as a recovery board and overtayment protection board for potyisocyanurate and polystyrene insulation. DensDeck Roof Board can also be used as a form board for poured gypsum concrete deck in roof applications as web as a substrate for spray foam roofing systems. 1/2" (12.7 mm) and 5/8" (15.9 mm) DensDeck Roof Board may also be used in vertical applications as a backer board or liner for the roof side of parapet walls. membrane manufacturers have hot mop asphalt or torch applications directly insDeck Roof Board without using a primer or base sheet. Consult with the system manufacturer for their recommendations with this application. DensDeck Roof Board is the preferred substrate for vapor retarders. Standards and Code Approvals DensDeck Roof Boards are manufactured to meet ASTM C 1177 and have the following approvals: • Florida Product Approval Code FL 1250 • Miami -Dade County, Florida NOA. 08-0908.10 Recommendations and Limitations DensDeck Roof Boards are manufactured to act with a properly designed roof system following good roofing practices. The actual use of DensDeck Roof Board as a roofing component in any system or assembly is the responsibility of the roofing system's design authority. Consult with the appropriate system manufacturer and/or design authority for system and assembly specifications and instructions on applying other products to DensDeck Roof Board. Georgia-Pacific does not warrant and is not responsible for any systems or assemblies utilizing DensDeck Roof Board or any component in such systems or assemblies other than DensDeck Roof Board. The need for a separator sheet between the DensDeck Roof Board and the roofing membrane must be determined by the roof membrane manufacturer or roofing system designer. Submittal Approvals Job Name Contractor Date 5-2 Technical Service Hotline 1.800.225.6119 or www.deflsdeck.cofif Confirm any priming requirements with the membrane manufacturer. When applying solvent -based adhesives or primers, allow sufficient time for the solvent to flash off to avoid damage to roofing components. DensDeck Roof Boards should not be subjected to abnormal or excessive loads or foot traffic, such as, but not limited to, use on plaza decks or under sleet -wheeled equipment that may fracture or damage the panels. Provide suitable rooting system protection when required. When using DensDeck Roof Boards for hot-rnopped applications, Georgia-Pacific recommends maximum asphalt application temperatures for Type III asphalt of 425°F1218°C) to 450°F (232°C). Application temperatures above these recommended temperatures may adversely affect roof system performance. For application temper- atures in excess of 450°F (232°C) and for mopping of type IV asphalt, ribbon or spot mopping or the installation of a perforated base sheet are recommended methods of bonding asphalt in lieu of full mopping. Consult and follow the roofing system manu- facturer's specifications for full mopping applications and temperature requirements. Conditions beyond the control of Georgia -pacific., such as weather conditions, dew, leaks, application temperatures and techniques may cause adverse effects with roofing systems. Moisture Management DensDeck Roof Boards, like other components used in roofing systems, must be protected from exposure to moisture before, during and after installation. Remove the plastic packaging from all DensDeck Roof Board immediately upon receipt of delivery. Failure to remove the plastic packaging may result in entrapment of con- densation or moisture. DensDeck Roof Board stored outside must be stored level and off the ground and protected by a breathable waterproof covering. Provide means for air circulation around and under stored bundles of DensDeck Roof Board. DensDeck Roof Board must be covered the same day as installed. Avoid application of DensDeck Roof Beards during rain, heavy fog and any other condi- tions that may deposit moisture on the surface, and avoid the overuse of non -vented, direct -fired heaters during winter months. When roofing systems are installed on new poured concrete or light weight concrete decks or when re -roofing over a wet existing concrete deck, a venting base sheet or vapor retarder should be installed above the concrete to retard the migration of water from the concrete into the roof assembly. Always consult the roofing system manufacturer or design authority for specific instructions for applying other products to DensDeck Roof Boards. Moisture vapor movement by convection must be eliminated, and the flow of water by gravity through imperfections in the roof system must be controlled. After a leak has occurred, no condensation on the upper surface of the system should be tolerated, and the water introduced by the leak must be dissipated to the building interior in a minimum amount of time. Although DensDeck Roof Boards are engineered with fiberglass facings and high density gypsum cores, the presence of free moisture can have a detrimental effect Oil the performance of the product and the installation of roofing membranes. For example, hot asphalt applications can blister; torched modified bitumen may not properly bond; and adhesives for single *membranes may not dry properly- Moisture accumulation • may also significantly decrease wind uplift and vertical pull resistance in the system or assembly. DensDeck Roof Boards containing excessive free moisture content may need to be evaluated for structural stability to assure wind uplift performance. continued---y Georgia-Pacific Technical Service Hotline 1.800.225.6119 or vv'vvv.densdeck.ccm E. the conditions identified by FM. For more information concerning FM Approvals and Roof Board ire Resistance Classifications DensDecka Roof Boards are excellent fire barriers over combustible and noncombustible roof decks, including steel decks. ill 790Ciassificarion. DensDeck Roof Boards have been classified by Underwriters Laboratories (UL) for use as a fire barrier over combustible and noncombustible decks in accordance with the ANSI/UL 790 test standard. The UL classification includes a comprehensive Class A. 8 or C rating. For additional information concerning the UL 790 classification, consult the UL Certification Directory. (:2 1256Cl;ssr/icafion. DensDeck Roof Boards have also been classified by UL in roof deck constructions for internal (under deck) fire exposure in accordance with the ANSI/UL 1256 Steiner Tunnel test. For additional information concerning the UL 1256 classification, consult the UL Certification Directory. FM Class 1 Approvals. DensDeck Roof Boards are included in numerous roofing assemblies with a Factory Mutual (FM) Class 1 fire rating. 1/4" (6.4 mm( DensDeck Roof Boards have passed testing under the FM Calorimeter Standard 4450 and have been approved by FM as such for insulated steel deck roofs when installed according Physical Properties Thickness, nominal Width, standard Length, standard Weight, nominal, lbs./sq, ft. (Kg/m2) Surfacing Flexural Strength', parallel, I bf. min (N) Flute Spanability7 Permeance7, Perms (ng/Pa• S • rrt7) Value', ft2-°F•hr/BTU (m7-K/W( ar Variation with Change in Temp., in/in °F (mm/mm/C°) Linear Variation with Change in Moisture Water Absorption', % max Compressive Strength', psi nominal Surface Water Absorption, grams, nominal Flame Spread, Smoke Developed (ASTM E 84) Bending Radius 1. Tested in accordance with ASTM C 473 method B. 2. Tested in accordance with ASTM E 561. 3. Tested in accordance with ASTM E 95 (dry cup method). AIN L� cif Georgia�a cf!'c Gypsum U.S.A.- Georgia-Pacific Gypsum LLC Canada -Georgia-Pacific Canada LP FM Class 1 assembl ies es with DensDeck Roof Boards, consult FM or RoofNav�'. Type X 5/8" (15.9 mm) DensDeck® Fireguard' Roof Boards are manufactured to meet the "Type X" requirements of ASTM C 1177 for increased fire resistance beyond regular gypsum board. Ul Fate Resi.Sta;:ca Ravings. 5/8" (15.9 mm( DensDeck Fireguard Roof Boards are designated as Type OD by UL and included in assembly designs investigated by UL for hourly fire resistance ratings. 5/8" (15.9 mm) DensDeck Fireguard Roof Boards may also replace any unclassified 5/8" (15.9 mm) gypsum board in an assembly in the UL Fire Resistance Directory under the prefix "P". Flame Spread and Smoke Developed. When tested in accordance with ASTM E 84, DensDeck Roof Boards had Flame Spread 0, Smoke Developed 0. Wind Uplift DensDeck Roof Boards are included in numerous assemblies evaluated by FM or other independent laboratories for wind uplift performance. For information concerning such assemblies, please visit www.rootnay.com. rA''•"'r -r r .0.1. -7 .1 r, i'nn ..51,Ci:f =r-1. ,. 1/4 (6.4 mm)+ 1/16" (1.6 mm) 1/2" (12.7 mm)± 1/32" 1.8 mm)�� 4'(1219mm) 4'(1219mm) ±1/8"(3mm) 8' (2438 mm) ± 1/4" (6.4 mm) 2.0 (9.8) ± 1/8" (3 mm) 8' (2438 mm) ± 1/4" (6.4 mm) 1.2 (5.9) Fiberglass mat 40 (178) 2-5/8" (67 mm) >50 (>2850) 28 8.5x106(15.3x10'6) 6.25 x 10•6 10. 900 0/0 5_11524 mm( Fiberglass mat 80 (356) 5" (127 mm) >35 (>1995) 56 8.5x104(15.3x101 6.25 x 10.6 10.0 900 8' (2438 mm( 4. Tested in accordance with ASTM C 518 (heat flow 5. Tested in accordance with ASTM C 1177. 6. Tested in accordance with ASTM C 473. SALES INFORMATION AND ORDER PLACEMEPdT USA. Midwest: 1-800-876-4746 West: 1-900-C24-7503 South: 1-800-327-2344 Northeast: 1-800.947-4497 CANADA Canada Toll Free: 1-800-387-6823 Quebec Toll Free: 1-800-361.0486 TECHNICAL INFORMATION U.S.A. and Canada:1-800.225-6119 vAvw.gpgypsum:com Q2011 Georgin.Paotic Gypsum U.C. An rights reserved. Ponied in the U.S.A. nn 105, pesItonsumer recycled stock 1/11 GP -TM Lit. hero ;101515 TRADEMARKS OENSDECK, FIREGUARD and the GEORGIA-PACIFIC logo are trademarks owned by or licensed to Georgia-Pacific Gypsum LLC. ROOFNAV is a registered mark of FM Global. WARRANTIES, REMEDIES AND TERMS OF SALE For current warranty information for this product, please go to www.gpgypsum.com.and select the product for warranty information. All sales of this product by Georgia-Pacific are subject to our Terms of Sale akiailable at www.gpgypsum.com. UPDATES AND CURRENT INFORMATION The information in this document may change without notice. Visit our website at www. gpgypsum.com for updates and current information. CAUTION For product fire, safety and use information, go to www.gp.com/safetyinfo or cal(1-800-225-6119. HANDLING AND USE -CAUTION This product contains fiberglass facings which may cause skin irritation. Dust and fibers produced r during the handling and installation of the a a, jU))=fir' t2,�r 9 mm(± 1/32" (.9 mm) 4'(1219mrn)±1/8"(3mm) 8' (2438 mm) ± 1/4" (6.4 mm( 2.5 (12.2) 5/8" (15 Fiberglass mat 100 (444) 8" (203 mm) >32 (>1824) 67 8.5x106(15.3x10.6) 6.25x106 10.0 900 s2.5 0/0 12_(3658 mm) product may cause skin, eye and respiratory tract irritation. Avoid breathing dust and minimize contact with skin and eyes. Wear long sleeve shirts, long pants and eye protection. Always maintain adequate ventilation. Use a dust mask or NIOSH/MSHA approved respirator as appropriate in dusty or poorly ventilated areas. FIRE SAFETY CAUTION Passing a fire test in a controlled laboratory setting and/or certi- fying or labeling a product as having a one -hour, Iwo -hour, or any other fire resistance or pro- tection rating and, therefore, as acceptable for use in certain fire rated assemblies/systems, does not mean that either a particular assem- bly/system incorporating the product, or any given piece of the product itself, will neces- sarily provide one -hour fire resistance, two-hour fire resistance, or any other specified fire resistance or protection in an actual fire. In the event of an actual fire, you should imme- diately take any and all actions necessary for your safety and the safety of others without egard for any fire rating of any product or ssembly/system. .000 X i/ Please provide --I- structural calcs for RTU Lennox Industries Inc. - Product Submittal Table of Contents RTU System ID Qty Model Description LANDMARK 3T 1 KGA036S4D PKGGE/3 TON/105KB/460-3 LANDMARK 4T 1 KGA048S4D PKGGE/4 TON/65KB/460-3 LANDMARK 5T 1 KGA060S4D PKGGE/5 TON/65KB/460-3 LANDMARK 6T 1 KGA072S4B PKGGE/6 TON/150KB/460-3 LANDMARK 7.5T NO LOCAL STOCK 1 KGA090S4B PKGGE/7.5T/105KB/460-3 LANDMARK 7.5T PLUS ADD ENTHALP 1 KGA092S4B PKGGE/7.5T/180KB/460-3/EC ENV LANDMARK 8.5T NO LOCAL STOCK 1 KGA102S4B PKGGE/8.5T/130KB/460-3 ENV LANDMARK 10T 1 KGA120S4B PKGGE/10T/180KB/460-3 ENV LANDMARK 12.5T NO LOCAL STOCK 1 KGA150S4B PKGGE/12.5T/180KB/460-3 ENV Project: 3000357934 Pricing Landmark 460-3 3-12.5 Last Changed: CHRIS GREGORY Quote: 4000477519 Pricing Landmark 460-3 3-12.5 Prepared On: 2014-02-12 Page 1 of 56 Phone: Lennox Industries Inc. - Product Submittal System ID: LANDMARK 5T Package Model: KGA060S4D Description: PKGGE/5 TON/65KB/460-3 HEATING PERFORMANCE Heat Source H/E Lowlnput H/E LowOutput H/E HighInput H/E HighOutput System HeatOutput Natural Gas 0 (Btuh) 0 (Btuh) 65000 (Btuh) 52000 (Btuh) 52000 (Btuh) Gas Supply Connection H/E Heat Rise AFUE/ ThermalEff Number of Heating Stages Gas Supply Pressure 0.50 (in.) 24.1 (°F) 80 1 7 (in.WC) COOLING PERFORMANCE Refrigerant ARI EER ARI SEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Coil NetTotalCool Coil GrossSensCool Coil NetSensCool Tube/Fin Humiditrol Refrigerant Charge Tube/Fin Refrigerant Charge Environ Refrigerant Charge R-410A 11.0 13.0 5300 (W) 61800 (Btuh) 59000 (Btuh) 61826 (Btuh) 59443 (Btuh) 44614 (Btuh) 42231 (Btuh) 0 0 0 Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB System MoistRemoval Coil MoistureRemoval 1 1 1.00 (in.) 95.0 (°F) 80.0 (°F) 67.0 (°F) 58.9 (°F) 56.9 (°F) 60.1 (°F) 57.3 (°F) 16.2 (lb/hr) 16.2 (lb/hr) SUPPLY FAN PERFORMANCE Supply Fan Total Air Flow Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDrive Speed 2008 (cfm) 2008 (cfm) 0.60 (in.WC) 0.75 (hp) 0.75 (hp) CAV Direct Drive 2 TotalStaticPress Gas H/E Static Press Added Filter Static Press Economizer Static Press Curb Stat Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.65 (in.WC) 0.00 (in.WC) 0.00 (in.WC) 0.05 (in.WC) 0.00 (in.WC) 4 16.0 (in.) 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range-Nom Voltage 460V 3Ph 60 (Hz) 14.0 (amp) 20 (amp) 8.0 (amp) 11.5 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 2.2 (amp) 1.3 (amp) 370 (W) DIMENSIONS Cabinet Width 47.0 (in.) Downflow Supply Length 18.0 (in.) Cabinet Length 83.3 (in.) Downflow Supply Width 20.0 (in.) Cabinet Height 36.4 (in.) Downflow Return Length 11.0 (in.) Total Weight 846 (lb) Downflow Return Width 29.0 (in.) Project: 3000357934 Pricing Landmark 460-3 3-12.5 Quote: 4000477519 Pricing Landmark 460-3 3-12.5 Page 14 of 56 Last Changed: CHRIS GREGORY Prepared On: 2014-02-12 Phone: Lennox Industries Inc. - Product Submittal System ID: LANDMARK 5T Package Model: KGA060S4D Description: PKGGE/5 TON/65KB/460-3 SYSTEM FEATURES Durable Outdoor Enamel Paint Finish Scroll Compressor Expansion Valves High Capacity Driers Separate Compressor and Controls Compartment Limited compressor warranty of 5 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details AGA-CGA Certified Redundant Comb. Gas Control Valve Electronic Flame Sensor Direct Spark Ignition Aluminized Steel Inshot Burners Limited warranty on aluminized heat exchanger of 10 years INCLUDED SYSTEM OPTIONS - FACTORY INSTALLED CONSTANT AIR VOLUME DIRECT DRIVE 2 IN MERV4 FILTER INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 13W27 90W61 53W64 TICURBIOAN1 DNFLOW CURB -14" STANDARD K I ECON30A-2 ECONOMIZER - SHORT C 1 SNSR64FF 1 SINGLE ENTHALPY Project: 3000357934 Pricing Landmark 460-3 3-12.5 Quote: 4000477519 Pricing Landmark 460-3 3-12.5 Page 15 of 56 Last Changed: CHRIS GREGORY Prepared On: 2014-02-12 Phone: Lennox Industries Inc. - Product Submittal System ID: LANDMARK 5T Package Model: KGA060S4D Description: PKGGE/5 TON/65KB/460-3 DIMENSIONS - INCHES (MM) Model No. CORNER AA Base Ibs. kg WEIGHTS Max. lbs. kg BB Base Ibs. kg Max. Ibs. kg CC Base lbs. kg Max. Ibs. kg DD Base lbs. kg Max. Ibs. kg CENTER OF EE Base in. mm GRAVITY Max. in. mm FF Base in. mm Max. in. mm 024 92 42 113 52 112 51 128 58 180 82 207 94 148 67 183 83 38-1/2 978 40 1016 18 457 18 457 030 92 42 114 52 112 51 129 58 180 82 207 94 149 68 183 83 38-1/2 978 40 1016 18 457 18 457 036 92 42 114 52 112 51 129 59 181 82 208 94 149 68 184 83 38-1/2 978 40 1016 18 457 18 457 048 99 45 123 56 120 55 139 63 193 88 223 102 159 72 197 90 38-1/2 978 40 1016 18 457 18 457 060 104 47 128 58 126 57 145 66 203 92 233 106 167 76 206 94 38-1/2 978 40 1016 18 457 18 457 072 121 55 143 65 147 67 162 74 237 108 261 119 195 89 231 105 38-1/2 978 40 1016 18 457 18 457 090 168 76 195 :•: 183 83 212 96 227 103 263 119 203 95 241 109 47 1194 47 1194 21 533 21 533 Base Und - The and wrlh standard heat exchanger NO OPTIONS. Max. Unit • The unit with ALL OPTIONS Installed. (High Input Heal Exchanger. Economizer. etc ) 5-5/8 18 (143) 11 (413)l(457)� AA (279) 100 0 y Ej 001 47(1192) �I BASE END VIEW it (25) 1 Project: 3000357934 Pricing Landmark 460-3 3-12.5 Quote: 4000477519 Pricing Landmark 460-3 3-12.5 Page 16 of 56 FORKLIFT SLOTS 5.12 (Front. Back and (140) Blower End) 7 (178) 29 (737) 47 192) i BASE 31/2 BOTTOM 1 5(102) RETURN O AIR OPENING S1JBOPLM S AMPLY/ AR OPENING 1 20 (508) CENTER OF 7TGRAVITY 6-5r8 �0 FF (168) T \ t DD 261/2Bo7TOM (673) ' CONDENSATE OUTLET 25-3/4 (654) 024 thru 072 38-3/4 (984) 090 \ j 9-1/2 (241) EE —� BOTTOM POWER ENTRY 3X8(76X203) TOP VIEW (Base) 83-1/4 (2115) 024 thru 072 96-1/4 (2445) 090 r_ CONDENSATE OUTLET (EITHER SIDE)"' _ FLUE/VENT OUTLET \ M— }f14120) ( 0 ® / ELECTRICAL INLET /GAS INLET I II IIII' I' r IIII --� 75 (381) I —} I I 261 /2261 /2 LIFTING HOLES (673) (For rigging) 27 (686) 85-1/4 (2165) 024 thru 072 BASE _ 98-1/4 (2496) 090 BASE SIDE VIEW 11 19-12 163/8 �(279) (495) (467)'�— 1I Il II II it !Oil I (508) �— a -- BB CC 1 (25) 2 (51) 29 (737) / = \/00 1 T HORIZONTAL HORIZONTAL 6-71/2 SUPPLY AIR RETURN AIR (140) OPENING OPENING (Without Economizer) BACK VIEW Last Changed: CHRIS GREGORY Prepared On: 2014-02-12 Phone: Lennox Industries Inc. - Product Submittal System ID: LANDMARK 5T Package Model: KGA060S4D Description: PKGGE/5 TON/65KB/460-3 OUTDOOR AIR HOOD DETAIL FOR OPTIONAL ECONOMIZER AND BAROMETRIC RELIEF DAMPERS (Downflow Applications) 13/4 (400) 024 00 15314 (400) 072 72 and 090 OPTIONAL OUTDOOR \ AIR HOOD (Furnished with Economizer) 12 (305) OPTIONAL BAROMETRIC/ RELIEF HOOD 10 C I 1 t J (Furnished with Economizer) SIDE VIEW OUTDOOR AIR HOOD FOR ECONOMIZER (Furnished) 0 C 41- C BAROMETRIC RELIEF HOOD FOR ECONOMIZER (Furnished) Model No. in. A mm in. B mm in. C mm 024, 030, 036, 048, 060 19-1/4 489 13 330 11-3/4 298 072, 090 23-1/4 591 17 432 15-3/4 400 Project: 3000357934 Pricing Landmark 460-3 3-12.5 Last Changed: CHRIS GREGORY Quote: 4000477519 Pricing Landmark 460-3 3-12.5 Prepared On: 2014-02-12 Page 17 of 56 Phone: City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director January 13, 2015 Alex Burkhart Evergreen Refrigeration, LLC 727 S Kenyon Street Seattle, WA 98018 RE: Request for Extensions Permit Numbers M14-0137 through M14-0141 and EL14-0657 Dear Mr. Burkhart, This letter is in response to your written request for an extension to Permits M14-0137, M14-0138, M14- 0139, M14-0140, M14-0141, and EL14-0657. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permits. It has been determined that the City of Tukwila Building Division will be granting an extension to the mechanical permits for an additional 180 days, through July 20, 2015. Unfortunately the request for extension was received after the January 6, 2015 expiration date for EL14- 0657 and consequently it cannot be extended. In order to begin or complete the scope of work for this permit a new application must be submitted along with associated fees. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, shall ician File: Permit No. M14-0137, M14-0138, M14-0139, M14-0140, M14-0141, & EL14-0657 W:\Permit Center\Extension Letters\Permits\2014\M14-0137 Permit Extension.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 dr* • 1 Evergreen Refrigeration HVAC REQUEST FOR PERMIT EXTENSION To: City of Tukwila Department of Community Development Attn: Building Official Project: Interurban Office Building A Address: 14550 Interurban Ave S 'A( FF Permit #: M14-0137 & EL14-0657•- Q,.(P ROUE t lJ Project: Interurban Office Building B Address: 14590 Interurban Ave S Permit #: M14-0138 Project: Interurban Office Building C Address: 14570 Interurban Ave S Permit #: M14-0139 Project: Interurban Office Building D Address: 14520 Interurban Ave S Permit #: M14-0140 Project: Interurban Office Building E Address: 14510 Interurban Ave S Permit #: M14-0141 HVAC & CONTROLS DESIGN INSTALLATION SERVICE I Request for Extension # Current Expiration Date: Extension Request: 31 Approved for / b days ❑ Denied (provide explanation) Signature,/Initials I would like to request an extension to the six (6) permits listed above. We applied for and picked up the permits well before the project actually began because it was our understanding the project would be kicking off sooner than it did. We are currently working on these buildings now but the work will not be completed by the time these permits expire. Sincerely, Alex Burkhart Evergreen Refrigeration, LLC 727 South Kenyon St. Seattle, WA 98018 , 206-763-1744 ext. 247 alexb@evergreenhvac.com 727 SOUTH KENYON ST. - SEATTLE, WA. 98108 (206) 763-1744 - Fax (206) 763-2389 00° RECEIVED CITY OF TUKWILA JAN 0 7 2015 PERMIT CENTER City of Tukwila Department of Community Development 12/1/2014 ALEX BURKHART 727 S KENYON ST SEATTLE, WA 98108 RE: Permit No. M14-0137 INTERURBAN OFFICE BUILDING A 14550 INTERURBAN AVE S Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 1/21/2015. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 1/21/2015, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M14-0137 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0137 DATE: ' 07/10/2014 PROJECT NAME: INTERURBAN OFFICE BUILDING A SITE ADDRESS: 14550 INTERURBAN AVE S X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division Rum Public Works Ahr\ Ay/i- Fire Prevention Structural Planning Division Permit Coordinator n n PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 07/ t /14 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved n Corrections Required (corrections entered in Reviews) DUE DATE: OVI,12/14 Approved with Conditions Denied ❑ (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 EVERGREEN REFRIGERATION I T C Page 1 of 3 4111111) Washington State Department of Lab©r & Industries EVERGREEN REFRIGERATION LLC Owner or tradesperson PATTON, RODGER Principals PATTON, RODGER, PARTNER/MEMBER PATTON, MATTHEW, PARTNER/MEMBER Patton, Adam, PARTNER/MEMBER Patton, Douglas, PARTNER/MEMBER EVERGREEN REFRIGERATION LLC, PARTNER/MEMBER PATTON, DAVID, PARTNER/MEMBER (End: 01/21/2014) Doing business as EVERGREEN REFRIGERATION LLC WA UBI No. 602 512 953 727 S KENYON ST SEATTLE, WA 98108 206-763-1744 KING County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. EVERGRL954R2 Effective — expiration 01 /06/2006— 01 /06/2016 Bond Merchants Bonding Co (Mutual) Bond account no. WA15097 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 12/15/2011 01 /01 /2012 Expiration date Until Canceled TRAVELERS CAS & SURETY CO $12,000.00 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602512953&LIC=EVERGRL954R2&SAW= 07/25/2014