Loading...
HomeMy WebLinkAboutPermit M14-0138 - INTERURBAN OFFICE BUILDING B - UNIT AND WALL HEATERSINTERURBAN OFFICE BUILDING B 14590 INTERURBAN AVE S M14-0138 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No: 3365901630 Permit Number: M14-0138 Address: 14590 INTERURBAN AVE S Issue Date: 7/25/2014 Permit Expires On: 1/21/2015 Project Name: INTERURBAN OFFICE BUILDING B Owner: Name: SANFT LOUIE Address: 6120 S2ND AVE S, SEATTLE, WA, 98118 Contact Person: Name: ALEX BURKHART Phone: (206) 763-1744 Address: 727 S KENYON ST , SEATTLE, WA, 98108 Contractor: Name: EVERGREEN REFRIGERATION LLC Phone: (206) 763-1744 Address: 727 S KENYON ST , SEATTLE, WA, 98108 License No: EVERGRL954R2 Expiration Date: 1/6/2016 Lender: Name: Address: , , , DESCRIPTION OF WORK: INSTALLATION OF (1) UNIT HEATER AND (1) ELECTRIC WALL HEATER Valuation of Work: $3,000.00 Type of Work: NEW Fuel type: GAS Fees Collected: $233.88 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2012 2012 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date: 1 /25 /C'f / Print Name: !"l— Lbw This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL ibek CITY OF TUKW 1 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** King Co Assessor's Tax No.: 336 5 0 f S 0 Site Address: I 510 vl4'A, h tee. S Tenant Name: O' Name: 6_0v ve,s+w`criA-s LiiC . Address: 1 i-Z Forte }-- A,,, 5E City: / State: �A Zip: CONTACT PERSON - person receiving all project communication Name: a h •fit Address: 17_,i 501A-1 (to„,,, 5k. . City: CQ State: j/ Zip: tj gloy Phone: -2,0 6 _163 _ V14.F c{. Fax: = 741. ?'i Email: ocitti.,be eve0 \ rsc..h v_xc o t o1,-, Suite Number: Floor: New Tenant: D Yes ❑ .. No Company Name: o 1 asem_t Address: - -Z Saki k6.,.0,,,, sd_ City: 5„,6 le.- State:Ws_ Zip: /1fril Phone: 2oc,-143 -- IZ4-4 Fax: 2e l; --? 3 - 232q Contr Reg No.:.uFCZ .,,i 54 ja.. 2 Exp Date: t / 4 / t6 Tukwila Business License No.: (3 LJS _ to i B 7-1 Valuation of project (contractor's bid price): $ 3 i(-D Describe the scope of work in detail: I wS rti1dt� vie.- C�' (J t+ ► -r- Use: Residential: New ❑ Replacement ❑ Commercial: New 5 Replacement ❑ 4 ltie�ri*v . Fuel Type: Electric ❑ Gas ....... [r Other: H:\Applications\Forms-Applications On Line\2011 Applications Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Fumace <100k btu Fumace > 100k btu Floor furnace Suspended/wall/floor mounted heater 2 Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: g/ Signature: �I-' Date: % / A 14- Print Name: A" Bw11' Day Telephone: C, ^ -� 3 ^ 1Z4L Mailing Address: 12-1 SO ` 4-1 Y ` ,6vN 5 • 56-$. W/- l g i d e City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-1I.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK a� G�b�a5, �� xn° '«b+. `. pi± ..1 0� ACCOUNT � , .c `Sk QUANTITY I PAID � ,:dINR4''!'`,�»t" ��� L 1,490:720p„� a�ifiT�:�.✓ a 'h g F.^x"ii. AI IU.hu �LH avSil',SPdk'i^b"e 4 . .r'N, t .t Or, rE o, , , ': `om ' a '. -41 :" ,,,;-, i ^" � � M BMV I II +r ., ,� Ala I� 0 �$77 28 EL14=0657 3 Address 14550 INTERURBAN AVE S Apn; 3365901605 y ; z� ; F M M1 � PP of a -x NvXad ,�..t n,;h dd"."�#�. .rYa3�,�e - .._ ELECTRICAL - $7360 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $73.60 TECHNOLOGY FEE $368 `� TECHNOLOGYwebFEE R000.322.900.04.00 0.00 $3.68 ?p S y. :"=q $ .!x,{+2 ^. Sb.: 01,o' YSAfAm;' goRm, eR='A# & Ct £ 1' A 't`; kA N:'s'.}`�."P jk,"k .skY�, `'�,J � daJ �° xR'.R' W x 4 M14 37x Address 14550 INTERURBAN AVE S Apn f3365901602168 rMECHANICAL $387.19 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $277.25 PLAN CHECK FEE R000.322.102.00.00 0.00 $77.44 TECHNOLOGY FEE .- ;, . _. - _ _ -• $15.49 .> TECHNOLOGY FEE R000.322.900.04.00 0.00 $15.49 I(T„'M15'4 Y P W R 3 ( GL J ? y. '„" a< 'ku " a' 1 '^4 ham." `L*E` ', , nM14=0138 Address', 14590 INTERURBAN AVE 5 Apn 3365901605 f "� s ° $233 88 MECHANICAL'. P n .4 �_. s = $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 0.00 $44.98 :TECHNOLOGY FEE " $9.000°=- TECHNOLOGY FEE R000.322.900.04.00 0.00 $9.00 : , 4! �j ,l "I .;."':T. fit. .:tit k �! ry,�F �' ,. ' ° ° , ,..:II ,.klk,';� 9 E .. a ,i }.b �. �'t f ,s 0 K'G ' 4 �' � i � � 1 Pa b ,,,,h �° , M14-0139 . Address 14570cINTERURBAN7AVE S 4Apn: 3365901605#4�'a�i$ 58 96 w- - MECHANICAL °` $249.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $166.70 PLAN CHECK FEE R000.322.102.00.00 0.00 $49.80 TECHNOLOGY FEE �$9.96 �- TECHNOLOGY FEE R000.322.900.04.00 0.00 $9.96 ���� fi, Wa M14-0140 Address 1 a� �« a , � �w�,* �, 4520 INTERURBAN-AVE:S Apn 3365901605, ` k a ^$258.96 ,. �=_sr �.. `.:.� _�..., .f r. s>r ra.°t ,. .;sae-i Wi„.t. .�-. ,: °:, -:'"x. _.x �_h..._ 1 .�""-m .Nv •ekh .�i M�aah , va 4a'.r+.:e. �:l�n'. MECHANICAL $249.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $166.70 PLAN CHECK FEE R000.322.102.00.00 0.00 $49.80 TECHNOLOGY FEE $9.96-; TECHNOLOGY FEE R000.322.900.04.00 0.00 $9.96 Date Paid: Thursday, July 10, 2014 Paid By: EVERGREEN REFRIGERATION, LLC Pay Method: CHECK 006580 Printed: Thursday, July 10, 2014 12:39 PM 1 of 2 CRWSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $1,490.72 M14-0141 Address: 14510 INTERURBAN AVE S Apn: 3365901605 $258.96 MECHANICAL $249.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $166.70 PLAN CHECK FEE R000.322.102.00.00 0.00 $49.80 TECHNOLOGY FEE $9.96 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2566 R000.322.900.04.00 0.00 $9.96 $1,490.72 Date Paid: Thursday, July 10, 2014 Paid By: EVERGREEN REFRIGERATION, LLC Pay Method: CHECK 006580 Printed: Thursday, July 10, 2014 12:39 PM 2 of 2 SYSTEMS (3) INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Afv_of38 Project _ / 8 u ctrtkoAcs— 6( Typktfipetycionti 1,Ati. i 'Address: 4Y-q° f/t#-t'' ‘ArCtVt Date Called: • Special Instructions: 4'44 Date?ntes...7 ..._(5__ a.m. P.m. 'Requester: Phone No: Approved per applicable codes. Corrections required prior to approval, OMMENTS: Inspector: _ LIREINSPECTION FEE REQUIRED. Priorto next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. NSPECTION RECORD Retain a copy with permit IN CTION NO, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., C00, Tukwila, WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 miti-oug P ojw: el._ 6(4c 6. Type 'alp rylon:pt vct i ----- orel: Ap(5 110 IrkfertArtocui /We\ D eCalled: 10 ( Special Instructions: iiii4 Date Wanted: "---2---1 - 0- a.m. p.rn. Requesteca FrC/1 Phone No: - b 79 3 ( ,J'` [3 Approved per applicable codes. Corrections required prior to approval. COMMENTS: szz cO—o,r Z1 te-t4k aLove_racf "R*- t-t-u4 11q-1 tie;ct terp-ks71-e-4-ks' cfell k-.e-(444reh Inspector: K....E., -Date: 5-2A —(J REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Summary MEOH-SUM Revised June 2013 n State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Projecomr lit No. Project Address 14690 Interurban Ave S Date 7/7/2014 Tukwila, WA 98188 For Building Dept. Use Rpplicant Name: Alex Burkhart Applicant Address: 727 South Kenyon St. Seattle, WA 98108 Applicant Phone: 206-763-1744 ext. 247 Project Briefly system Description describe mechanical type and features. Includes Plans Installation of one (1) unit heater and one (1) electric wall heater. Drawings must contain notes requiring compliance with commissioning provisions per Section C408 Compliance Option Simple System 0 Complex System O Systems Analysis Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu/h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exceptions Heat Recovery Y/N Heating Equipment Schedule Equip. ID Equip Type Brand Name1 Model No.1 Capacity2 Btu/h OSA cfm or Econo? Input Btuh Output Btuh Efficiency4 Heat Recovery Y/N UH-1 Reznor MAP 30 24600 N/A 30000 24600 82 N EWH-1 King PAW1215 N/A N/A N/A N/A N/A N Fan Equipment Schedule Equip. ID Equip Type Brand Name1 Model No.1 CFM SP1 HP/BHP Flow Controls Location of Service Service Water Heating Equipment Schedule RECEIVED =.:. ID REV '- �n p EWEQ3FaQName Model No.1 Input Capacity Sub- Category EF' ((�� ��'��rr T LiS�dtidn P er�ddi(Vi/IL/ CODE COMPLIANCE JUL 10 APPROVEQ 2014 2 201't PERMIT JUL 2 CEN I ER Iavailable. 2 As tested according Table C403.2.3(1)A thru C403.2.3(8). 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as alicable i� FIoow .n tfls: van ble air volume (VAV), constant volume (CV), or variable speed (VS). 6 Economizer exception number per BUILDING DIVISION MIt.hOli Mechanical Permit Plans Checklist - Page 1 of 3 MECH-CHK 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Address 14590 Interurban Ave S Date 7/7/2014 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes GENERAL PROVISIONS Equipment Sizing & Performance Yes C403.2.1 Load calculations Load calculations performed per ASHRAE Std 183 or equivalent per Chapter 3 M 1 Yes C403.2.2 Equipment and system sizing Output capacity of heating and cooling equipment and systems do not exceed calculated loads, note exceptions taken M 1 Yes .. C40325 Minimum ventilation Ventilation (natural or mechanical) provided per IMC; indicate mechanical ventilation is capable of being reduced to minimum requirement per IMC M1 Yes C403.2.3 & C403.2.3.2 &efficiency C403.2.12.1 Equipment minimum Provide equipment schedules or complete MECH-SUM tables with type, capacity, efficiency, test standard (or other efficiency source) for all mechanical equipment M1 N/A C403.2.13 Electric motor efficiency Provide equipment schedule with hp, rpm, efficiency for all motors; note except. N/A C403.2.10 Fan power limitation Fan system motor hp or bhp does not exceed limits per Table C403.2.10.1(1) N/A C403.2.10.3 & C403.2.13 Fractional hp fan motors Indicate fan motors 1/12 to 1 hp are ECM type or meet minimum efficiency req. N/A C403.2.3 capacity Maximum air cooled chiller Indicate air-cooled chiller capacity does not exceed air-cooled chiller limit N/A C403.2.1 Non-standard water-cooled chillers Full -load and NPLV values for water-cooled centrifugal chiller adjusted for non-standard operational conditions N/A C403.2.12.1.2 Centrifugal fan cooling towers Large capacity cooling towers with centrifugal fan(s) meet efficiency requirements for axial fan open circuit cooling towers N/A C403.2.3 Forced air furnace and unit heaters Indicate intermittent ignition or IID, flue/draft damper & jacket loss N/A C403.2.3.3 heating/coolinq equipment Packaged electric List equipment required to be heat pumps on schedule N/A C403.2.3.4 Humidification Indicate method of humidification (note requirements for systems with economizer) HVAC System Controls & Criteria Yes C403.2.4.1 Thermostatic controls Indicate locations of thermostatic control zones on plans, including perimeter systems M1 Yes C403.2.4.1.1 Heat pump supplementary heat Indicate staged heating (compression/supplemental) & outdoor lock -out temp M1 Yes C403.2.4.2 Setpoint overlap (deadband) Indicate 5°F deadband minimum for systems controlling both heating & cooling M1 Yes C403.2.4.3 Automatic setback and shutdown Indicate zone t-stat controls with required automatic setback & manual override M1 Yes C403.2.4.3.3 Automatic (optimum) start Indicate system controls that adjust equip start time to match load conditions M 1 Yes C402.4.5.2 & C403.2.4.4 Dampers Indicate location of OSA, exhaust, relief and return air dampers; include AMCA rated leakage and control type (motorized or gravity; note exceptions M1 Yes C403.2.11 Heating outside a building Indicate radiant heat system and occupancy controls M1 N/A C403.2.4.5 Snow melt systems Indicate shut-off controls based on outdoor conditions N/A C403.2.4.6 Combustion heating i equpment Indicate modulating or staged control N/A C403.2.4.7 Group R1 hotel/motel systems Indicate method for guest room automatic setback & set-up of 5°F minimum N/A C403.2.4.8 / 9 Group R2/R3 dwelling unit systems Indicate 5-2 programmable thermostats in primary spaces with minimum of two setback periods; note exceptions taken Yes C403.2.5.1 ventilation Demand controlled Indicate high -occupancy spaces and systems requiring DCV M1 Yes C403.2.5.2 Occupancy sensors Indicate spaces requiring occupancy -based system control and method; or alternate means provided to automatically reduce OSA when partially M1 Yes C403.2.5.3 Enclosed loading dock/parking garage ventilation Indicate enclosed loading dock and enclosed parking garage ventilation system activation and control method M 1 N/A C403.2.5.4.1 Kitchen exhaust hoods Indicate kitchen hoods requiring make-up air; indicate make-up air source and conditioning method N/A C403.2.5.4.2 Laboratory exhaust systems Indicate lab exhaust systems requiring heat recovery, method & efficiency; or alternative method taken (VAV, semi -conditioned makeup, or GERM calculation) N/A C403.2.6.1 Energy recovery - ventilation systems Indicate ventilation systems requiring ER, method & efficiency; note exceptions N/A C403.2.6.2 Energy recovery - condensate systems Indicate on -site steam heating systems requiring energy recovery N/A C403.2.6.3 Energy - er systems condenser Indicate remote refrig. condensers requiring ER and use of captured energy Mechanical Permit Plans Checklist - Page 2 of 3 MECH-CHK 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Address 14590 Interurban Ave S Date 7/7/2014 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes GENERAL PROVISIONS, CONTINUED HVAC System Controls & Criteria, Continued N/A C403.2.12 Variable flow control - fans/pumps Indicate fan & pump motors requiring VF control & method (VSD or equiv controls) N/A flow VaC403.2.12.1 cooling we control - cooling towers Indicate cooling tower fans requiring variable flow control and method N/A C403.2.12.2 Large volume fan systems Indicate fan systems requiring airflow reduction based on heating and cooling demand; or exception taken N/A C403.2.12.2 Single zone AC systems Indicate method of cooling demand -based fan control for sys. > 110,000 btuh N/A C403.2.4.10 DDC system capabilities Identify all DDC system input/output control points and indicate capability for trendina and demand response setooint adiustment Ducting Systems Yes C403.2.7.1 &Duct C403.2.7.3 construction Indicate all ductwork constructed and sealed per IMC, C402 leakage requirements and IBC vapor retarder requirements M1 N/A C403.2.7.3.1 ; Duct pressure classifications Identify location of low, medium and high pressure ductwork on plans N/A C403.2.7.3.3 High pressure duct leakage test Indicate high pressure duct leakage testing requirements on plans; provide test results to jurisdiction when completed Yes C403.2.7.1 / 2 Duct insulation Indicate R-value of insulation on ductwork M1 Piping Systems N/A C403.2.8 Piping insulation Indicate R-value of insulation on piping N/A C403.2.8.1 Piping insulation exposed to weather Indicate method of protection from damage/degredation SIMPLE SYSTEMS Qualifying Systems Yes C403.3 Qualifying single zone systems Verify unitary or packaged equipment does not exceed capacity limits, does not have active humidifcation or simultaneous heating/cooling M 1 N/A C403.3 systems Qualifying 2-pipe heating Verify 2-pipe heating -only system does not exceed capacity limits N/A C403.3.2 Hydronic system controls Refer to Complex Systems Section C403.4.3 Simple System Economizers Y25 C403.3.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip sched. M1 Yes C403.3.1.1.1 Air economizer capacity Indicate modulating OSA control capability up to 100% OSA, or exception M1 Yes C403.3.1.1.3 controls Air economizer high limit Indicate high limit shut-off control method per Table C403.3.1.1.3(2) M 1 Yes C403.1.1.2 Integrated air economizer operation Indicate capability for partial air economizer operation for systems with capacity > 65,000 btuh M 1 Yes C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exception(s) M1 COMPLEX SYSTEMS Complex System Economizers Yes C403.4.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip sched. M1 Yes C403.4.1.4 Economizer heating system impact Verify control method of HVAC systems with economizers does not increase building heating energy usage during normal operation M 1 Yes C403.4.1.3 Integrated economizer operation Indicate capability for partial economizer operation for air or water econo systems M 1 N/A Moved Water economizer capacity Indicate water econo capable of 100% cooling capacity at 50°F db/45°F wb OSA N/A C403.4.1.2 Water economizer maximum pressure drop Indicate precooling coils and heat exchangers do not exceed pressure drop limit N/A C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exception(s) Mechanical Permit Plans Checklist - Page 3 of 3 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 MECH-CHK Revised June 2013 Project Address 14590 Interurban Ave S Date 7/7/2014 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area In Excel prior to printing MECH-CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes COMPLEX SYSTEMS, CONTINUED Specific System Requirements N/A C403.4.2 & c403.2.12 Variable flow control - fans Indicate fans requiring variable flow control and method N/A C403.4.2.1 VAV fan static pressure sensors Indicate sensor locations on plans; include at least one sensor per major duct branch N/A C403.4.2.2 VAV fan static pressure setpoint Indicate fan system static pressure setpoint based on zone requiring most pressure N/A C403.4.5 VAV systems serving multi- zones Indicate supply air systems serving multiple zones that are required to be VAV, method of primary air control, and zones served; note exceptions taken N A / C403.4.5.4 VAV system supply air reset Indicate controls that automatically reset supply air temp in response to loads N/A C403.4 Large capacity cooling systems Indicate method of multi -stage or variable control for building cooling system capacity> 300 tons N/A C403.4.7 Hot gas bypass limitation Indicate cooling equipment unloading or capacity modulation method N/A C403.4.3 systems Large capacity boiler Indicate multi -stage or modulating burner for single boilers > 500,000 btuh N/A C403.4.3 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers N/A C403.4.3.5 Chiller / boiler plant pump isolation Indicate capability to automatically reduce overall plant flow and shut-off flow through chillers & boilers when not in use N/A C403.4.2 & C403.4.3.6 Variable flow control - pumps Indicate pumps requiring variable flow control & method N/A C404.2.12.103.4.4 & C403.4.4 Varcooling towers flow control - cooling Indicate cooling tower fans requiring variable flow control and method N/A / C403.4.3.4 Hydronic system part load controls Indicate heating & chilled water systems have the capability to automatically reset supply water temp AND reduce flow by >_ 50% for systems > 300,000 N/A C403.4.3.2 Two -pipe changeover systems Indicate deadband, heating/cooling mode scheduling and changeover temperature range N/A C403.4.3.3.1 Water loop heat pump - deadband Indicate capability of central equipment to provide min. 20°F water supply temp deadband between heat rejection and heat addition modes N/A C403.4.3.3 Water loop heat pump - heat rejection Provide heat exchanger that separates cooling tower and heat pump loop in Climate Zone 5 N/A C403.4.3.3.3 Water loop heat pump - isolation Indicate 2-way isolation valve on each heat pump and variable flow control for systems with total pump power > 10 hp N/A C403.4.6 recovery Condenser water heat Indicate system provided to pre -heat service water and efficiency N/A C403.5 Cooler / freezer - anti -sweat heaters Indicate w/sf & control method for walk-in cooler/freezer door anti -sweat heaters N/A C403.5 / 6 Cooler / freezer -evaporator and condenser fans Indicate motor type for evaporator and condenser.fans < 1 hp SERVICE WATER HEATING Service Wa er Systems N/A C404.2 Water -heating equip min. efficiency Provide equipment schedule or complete MECH-SUM table with type, capacity, efficiency, test standard (or other efficiency source) N/A C404.3 Temperature controls Indicate temperature controls have required setpoint capability N/A C404.4 Heat traps Indicate piping connected to equipment have heat traps on supply & discharge N/A C404.5 Insulation under water heater Indicate R-10 insulation under tank N/A C404.6 Service water piping insulation Indicate R-value of insulation on piping; note exceptions taken N/A C404.7 / 8 Circulation systems and heat trace shut-off Indicate shut-off capability based on occupancy and periods of limited demand N/A C404.9 Group R-2 service hot water meters Indicate method of usage metering for dwell. units served by central HW system Pools & In -Ground Permanently Installed Spas N/A C404.10.1 Pool heating equip min. efficiency Provide equipment schedule or complete MECH-SUM table with type, capacity, efficiency, test standard (or other eftt source); heat pump heaters > 4 COP N/A C404.10.1 / 2 Pool heater on / off controls Indicate automatic on/off control based on scheduling & accessible on/off switch on heater that operates independent of thermostat setting; or N/A C404.10.3 Pool covers Indicate vapor retardant cover and insulation rating as required N/A C404.10.3 Pool assembly insulation Indicate rating of insulation on sides and bottom of pools heated to > 90°F N/A C404.10.4 Heat recovery Indicate method, exhaust air temperature reduction and recovered energy use City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director January 13, 2015 Alex Burkhart Evergreen Refrigeration, LLC 727 S Kenyon Street Seattle, WA 98018 RE: Request for Extensions Permit Numbers M14-0137 through M14-0141 and EL14-0657 Dear Mr. Burkhart, This letter is in response to your written request for an extension to Permits M14-0137, M14-0138, M14- 0139, M14-0140, M14-0141, and EL14-0657. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permits. It has been determined that the City of Tukwila Building Division will be granting an extension to the mechanical permits for an additional 180 days, through July 20, 2015. Unfortunately the request for extension was received after the January 6, 2015 expiration date for EL14- 0657 and consequently it cannot be extended. In order to begin or complete the scope of work for this permit a new application must be submitted along with associated fees. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, shall ician File: Permit No. M14-0137, M14-0138, M14-0139, M14-0140, M14-0141, & EL14-0657 W:\Permit Center\Extension Letters\Permits\2014\M14-0137 Permit Extension.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 • Everareen 0 Refrigeration HVAC 5 REQUEST FOR PERMIT EXTENSION To: City of Tukwila Department of Community Development Attn: Building Official Project: Interurban Office Building A Address: 14550 Interurban Ave S Permit #: M14-0137 & EL14-0657•- e.tP Qt 0 L tC Project: Interurban Office Building B Address: 14590 Interurban Ave S Permit #: M14-0138 Project: Interurban Office Building C Address: 14570 Interurban Ave S Permit #: M14-0139 Project: Interurban Office Building D Address: 14520 Interurban Ave S Permit #: M14-0140 Project: Interurban Office Building E Address: 14510 Interurban Ave S Permit #: M14-0141 HVAC & CONTROLS DESIGN INSTALLATION SERVICE Request for Extension # Current Expiration Date: Ci 124 11.- Extension Request: Approved for / d o days Denied (provide explanation) Signature/Initials I would like to request an extension to the six (6) permits listed above. We applied for and picked up the permits well before the project actually began because it was our understanding the project would be kicking off sooner than it did. We are currently working on these buildings now but the work will not be completed by the time these permits expire. Sincerely, Alex Burkhart Evergreen Refrigeration, LLC 727 South Kenyon St. Seattle, WA 98018 , 206-763-1744 ext. 247 alexb@evergreenhvac.com 727 SOUTH KENYON ST. - SEATTLE, WA. 98108 (206) 763-1744 - FAx (206) 763-2389 RECEIVED CITY OF TUKWILA JAN 0 7 2015 PERMIT CENTER City of Tukwila Department of Community Development 12/1/2014 ALEX BURKHART 727 S KENYON ST SEATTLE, WA 98108 RE: Permit No. M14-0138 INTERURBAN OFFICE BUILDING B 14590 INTERURBAN AVE S Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 1/21/2015. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 1/21/2015, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M14-0138 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0138 DATE: 07/10/2014 PROJECT NAME: INTERURBAN OFFICE BUILDING B SITE ADDRESS: 14590 INTERURBAN AVE S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: C -TA'-I 11I Building Division 111 Public Works NO- Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 07/ 1914 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 0' 0/14 Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 EVERGREEN REFRIGERATION T T C Page 1 of 3 ilk Washington Stale Department of Labor & Industries EVERGREEN REFRIGERATION LLC Owner or tradesperson PATTON, RODGER Principals PATTON, RODGER, PARTNER/MEMBER PATTON, MATTHEW, PARTNER/MEMBER Patton, Adam, PARTNER/MEMBER Patton, Douglas, PARTNER/MEMBER EVERGREEN REFRIGERATION LLC, PARTNER/MEMBER PATTON, DAVID, PARTNER/MEMBER (End: 01/21/2014) Doing business as EVERGREEN REFRIGERATION LLC WA UBI No. 602 512 953 727 S KENYON ST SEATTLE, WA 98108 206-763-1744 KING County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. EVERGRL954R2 Effective — expiration 01/06/2006— 01/06/2016 Bond Merchants Bonding Co (Mutual) Bond account no. WA15097 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 12/15/2011 01 /01 /2012 Expiration date Until Canceled TRAVELERS CAS & SURETY CO $12,000.00 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602512953&LIC=EVERGRL954R2&SAW= 07/25/2014