Loading...
HomeMy WebLinkAboutPermit M14-0150 - FINE DESIGNS - ROOFTOP UNITSFINE DESIGNS 16550 W VALLEY HWY M14-0150 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov MECHANICAL PERMIT Parcel No: 2523049084 Permit Number: M14-0150 Address: 16550 W VALLEY HWY BLDG A Issue Date: 8/19/2014 Permit Expires On: 2/15/2015 Project Name: FINE DESIGNS Owner: Name: FINE DESIGNS Address: 621 W SURF SPRAY LN , PONTE VEDRA BEACH, WA, 92082 Contact Person: Name: ARCHIE TYSYACHUK Phone: (253) 315-2588 Address: 12515 224 AVE E , BONNEY LAKE, WA, 98391 Contractor: Name: BROTHERS HEATING LLC Phone: (253) 862-8845 Address: 12515 224 AVE E , BONNEY LAKE, WA, 98391 License No: BROTHHL878RC Expiration Date: 12/3/2015 Lender: Name: Address: III DESCRIPTION OF WORK: REMOVE AND REPLACE TWO ROOFTOP UNITS Valuation of Work: $17,000.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $415.74 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2012 2012 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: 0 - This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 12: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKN 4 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical 1-vrmit No. 1S41 1-4--O j Project No. Date Application Accepted: Li Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: %6 5-5-0 VA. I1c n c,�� Tenant Name: F Ai— ()CS /. i'1 S PROPERTY OWNER Name: rl , pz_s 1 CJi lu Address: 16 SSO W Va lte _ a H City:Twcw1fry Stae: W1� y 'p:g0/eO CONTACT PERSON — person receiving all project communication ff� Name. • r LGvti ° + TyG. 6vl K. C. Address: IZS)S zti,4ye- E City: Ro n ✓l2- LQ At— State: r.1,4_ Zip: ad3ai Phone: 2 S3) ( j,� 2S p�Fax: 0 1 Email: At v0 r I_ i_ ,kteo.I a (GI% VlD4 m(tI I . coon King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: ❑ Yes .. No MECHANICAL CONTRACTOR INFORMATION Company Name: fz vD f rS LI & 4 &t t t L Address: ! s IS 2 4 4h live E City: Rowi e.. r _ State:GI) /� Zip: p? r' 0 I Phone: zs3 462 6G 00 Fax: Contr Reg No.: :01eg n .,• Tukwila Business License No.: n /1 1 1 i _- 4^1*5.l 1; 1 L—' Valuation of project (contractor's bid price): $ /710(00 jj Describe the scope of work in detail: lpp � VyloV_ 0.N lX re r Ike +&U 0 fO 0, top �� 1 Ts. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ placement ZI Fuel Fuel Type: Electric ❑ Gas Other: H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHO ZED AGENT: Signature: Print Name: Mailing Address: (2:5 IS 224 I7 v L Day Telephone: Date: 4/2 3/(c/ 206, S o-226/ 1.cvlkty Lam ton 48391 City State Zip H:\Applications\Forms-Applications 0n Line\2011 Applications\Mechanical Permit Application Revised 8-9-1 l.docx Revised: August 2011 bh Page 2 of 2 DESCRIPTIONS PermitTRAI Cash Register Receipt City of Tukwila ACCOUNT QUANTITY PAID �157.4 14/.01504 o dressi.16550.W.VALLEY HWY BLD' 2304908 15. MECHANICAL $399.75 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $287.30 PLAN CHECK FEE R000.322.102.00.00 0.00 $79.95 TECHNOLOGY FEE $15• 99 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2657 R000.322.900.04.00 0.00 $15.99 $415.74 Date Paid: Wednesday, July 23, 2014 Paid By: VITALIY TYSYACHUK BROTHERS HEA Pay Method: CREDIT CARD 115512 Printed: Wednesday, July 23, 2014 1:51 PM 1 of 1 CRWSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 Project: : Ai P -De 5 , (a /v S Type of Inspection: ; Z. J U G N: T ,f 1 Ai 4-1.,r. Address:_ _ l IA ` SO RAJ V -i (ev Date Called: / Special Instructions: _ , `' 1 Date Wanted %"��-14 arri.. p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: ,e 7,-) it, p 1 Inspector: Date .. S _ 4 I t REINSPECTI©N FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Rer IU,Cin Diu RTU2 SEPARATE PERMIT REQUIRED FOR: 0 Mechanical ISk Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION a e Permit No. WUtk1)6v Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By: Date: 4c j ct,19' City of Tukwila BUILDING DIVISION scope �DNsdeco ti �a� o`` e co .90090000.bM a� � 0�s� � 1 aiece sell 66�t �a\pia RTU-3 R u- RT u- iowasassamaZgaaal 1i-IOl5O 6.5 o ) vane, ire Lk) f ✓ s REVIEWED FOR CODE COMPLIANCI APPROVED AUG 15 2014 City • T BUILDIN • (a VISIO RECEIVED CITY OF TUKWILA JUL 2 3 2014 PERMIT CENTER TECHNICAL SPECIFICATIONS R8HE Series 3-Phase 95% AFUE Condensing Heat Exchanger offering 2-Stage Heating and 14 SEER Single -Stage Cooling with ECM Blower These single packaged gas/electrics arehigh efficiency self-contained cooling units that can be installed on a rooftop or at ground level on a slab. The unit design makes installations simple in all applications. Units are ETL and ETLc listed. City of Tukwila BOOING ti CORRECTION LTR#_I_ 14O 5a r2-tp16 euvicAA Viimt Jif MammQth® PV FEATURES and BENEFITS • Copeland Scroll Compressor: State of the art compressor is standard equipment. • Micro -Channel Coils: Both indoor and outdoor all aluminum coils are designed to optimize heat transfer, minimize size and cost, and increase durability and reliability. • Wire guard coated with earth friendly epoxy and plastic mesh hail guard: A guard that will never rust and protects the units coil from being damaged. • Easy Compressor and Control Access: Designed to make servicing easier for the contractor, access panels are provided to all controls and the compressor from the side of the unit. Easy access to the evaporator coil for cleaning and general maintenance. • R-410A Refrigerant: Earth friendly non -ozone depleting refrigerant. • Permanently Lubricated Condenser Motor. A heavy duty PSC motor for long lasting reliability and quiet operation. Requires no maintenance and is completely protected from rain and snow • Themwstatic ExpansionValves: Factory installed externally equalized thermostatic expansion valves provides precise refrigerant control under varying load conditions. • Hi/Low Pressure Switches: Ensure long compressor life. • Externally Accessible, Service Ports: Quick access to refrigeration system. • Liquid Line Filter Driers: Factory installed at a convenient location for service. • Quiet Operation and Low Vibration: Swept -wing fan blade combined with custom Venturi condenser fan. • 2-Stage Heat Operation: Featuring a 2-stage gas valve, 2-speed inducer motor, and 2 speed blower control. • Choice of Heating Control: Two stage thermostat or single stage heating thermostat with on the control board timing of a 10 minute delay for second stage of heat. • Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger. • Stainless Steel secondary heat exchanger: Assures a long life. • 100% fired and tested: All units and each component are tested on the manufacturing line. • 30 second blower delay: At start-up assures a warm duct temperature at start-up. Adjustable blower off settings (60, 90,120, and 180seconds) • 30 second inducer post purge: Increases fife of heat exchanger. • Hot Surface igniter: Innovative application of an appliance type igniter with a 20 year history of reliability. • SmartLiteTM Control Board: Provides extended life to igniters using hot surface ignition technology. Programmed to team the heat -up characteristics of the igniter, then adapt the ignition time to the characteristics of the furnace so the igniter is energized appropriately. • LP Convertible: Simple burner orifice and regulator spring change for ease of convertibility. • Designed using Galvanized Steel: With a polyester urethane coat finish. The 950 hour salt spray finish is 1.5 mil thick and resists corrosion 50% better than comparable units. • Corrosion -Resistant Drain Pan: Quickly drains away evaporator condensate. • Embossed Bottom Pan: Keeps blower component compartment dry. • Smaller Panels, Great Fit and Finish, Total Seal: Well -designed, quality construction. • One PieceTopPan: With drip edge ontop panels whisks away rainwater. • Low VoftageTransfomter: Includes 5 Amp fuse to protect low voltage circuit • Energy Efficient Brushless DC Blower Motor. ECM constant torque in all models. • Horizontal Air Delivery: To accommodate ground mount horizontal applications. • Heavy -Gauge, Full Perimeter Base Rails: Facilitates forklift handling and curb mounting. • RemovableTop Grille Assembly: Allows ease of service to the fan motor. • Duct Flanges: Reduce installation costs. • Proven,IndustryStandard Components: Eslectplmritabiltty. CITY OF TUKWILA AUG 1 1.2014 PFRIIAIT nr•.�-,....� MODEL IDENTIFICATION CODE R 8 H Application _._.) Gas/Electric Packaged Unit Series 95% AFUE High Efficiency Gas T T E =14 SEER X 24 C 080 X ."-EX = NOx ..,__Heating Capacity (000) Btu 'cal Code K = 208/230-60-1 C = 208/230-3-60 D = 460-3-60 -Cooling Capacity X =TXV (000) KIBtu DIMENSIONS 45.75 25 •t-12 ► 23.50 ANI 3/4" NPT FEMALE DRAIN CONNECTOR TOP VIEW SINGLE PHASE SHOWN INSIDE PERIMETER OF BASE RAIL (IF USED) DOWNFLOW RETURN DUCT OPENING 12 47.50 Model Number RBHE Unit Weight Shipping Weight Center of Gravity Unit Dimensions (inches) A B Height with base rail (C) Might without base rail Length Width R8HE-X36C080X 391 417 26.5 26.5 35 31.3 55.8 47.5 R8HE-X36D080X 408 434 26.0 27.0 35 31.3 55.8 47.5 RBHE-X48C096X 455 482 27.5 26.5 43 39.3 55.8 47.5 R8HE-X480096X 472 499 27.0 27.0 43 39.3 55.8 47.5 R8HE-X60C096X 485 510 28.0 26.5 47 43.3 55.8 47.5 R8HE-X600096X 502 527 27.5 27.0 47 43.3 55.8 47.5 -2 DIMENSIONS (Continued) ELECTRIC SUPPLY 2.03-- ENTRY (1.25" DIA.) LOW VOLTAGE ENTRY (0.875" DIA.) ---7.03-- --6.53 --5.40-- 28 25 65 25 15 1482 3 TON, 3 PHASE MODEL ONLY VENT ASSEMBLY (DOWNFtOW APPLICATION) • GAS SUPPLY ENTRY BLOWER ACCESS -� 1 . 0 00 2.03 Side View 47.50 FILTER ACCESS 3 PHASE ONLY 7 50 12 45 1.75 HORIZONTAL SUPPLY DUCT OPENING 16.0 13.5 • 8.75 HORIZONTAL RETURN DUCT OPENING 1 • 12.45 • 16.0 --r 1 135 4.0 • • CONDENSING COI -o 0 0 4.0 9.75 24.75 Back View 55.8 3 SPECIFICATIONS AND ELECTRICAL DATA THREE PHASE Model R8HE- 1 X36C080X 1 X36D080X X48C096J X48D096X 1 X600096X 1 X600096X Performance Data Cooling Capacity (Net) - (Btuh)(') 36,000 36,000 47,000 47,000 56,000 56,000 Efficiency - Cooling - S.E.E.R. m 14.00 14.00 14.00 14.00 14.00 14.00 Efficiency - Cooling - E.E.R a) 11.50 11.50 11.00 11.00 11.00 11.00 High Heating Input (Btuh) 80,000 80,000 96,000 96,000 96,000 96,000 High Heating Output (Btuh) 76,000 76,000 91,200 91,200 91,200 91,200 Low Heating Input (Btuh) 52,000 52,000 _ 62,400 62,400 62,400 62,400 Low Heating Output (Btuh) 49,400 49,400 59,300 59,300 59,300 59,300 Heating - A.F.U.E (2) 95.0% 95.0% 95.0% 95.0% 95.0% 95.0% Electrical Rating - 60 Hz. Phase 3 3 3 3 3 3 Operating Voltage 187-253 414-506 187-253 414-506 187-253 414-506 Minimum Circuit Ampacity - (MCA) 23.0 11.9 27.6 12.5 30.7 14.7 Max. Overcurrent Protection - (MOP) 30 15 _ 40 15 45 20 Compressor Data Compressor (Scroll) ZP31 K5E-TF5 ZP31 K5E-TFD ZP42K5E-TF5 ZP42K5E-TFD ZP51K5E-TF5 ZP51 K5E-TFD Volts 208/230 460 208/230 460 208/230 460 Rated Load Amps 11.6 6.4 15.3 6.9 17.8 8.6 Lock Rotor Amps 73 38 83 41 110 52 Indoor Blower Data Wheel - Diameter x Width 11" x 8" 11" x 8" 11" x 10" 11" x 10" 11" x 10' 11" x 10" Motor - HP / Type 1 - ECM 1 - ECM 1 - ECM 1 - ECM 1 - ECM 1 - ECM Motor Amps © 208V - 230 V 7.00 - 6.50 _ 3.30 - 3.00 7.00 - 6.50 __ 3.30 - 3.00 7.00 - 6.50 3.30 - 3.00 Outdoor Fan Motor-HP/RPM 1/4-1100 1/4-1100 1/4-1100 1/4-1100 1/4-1100 1/4-1100 Motor Amps 1.5 0.6 1.5 0.6 1.5 0.6 Fan Diameter 20" 20" 24" 24" 24" 24" Refrigerant Charge - oz. 57 S7 69 69 83 83 High Pressure Switch (PSIG) Cut Out 650 +/-15 Cut In: 460 +/-15 Loss of Charge Switch (PSIG) Cut Out 5 +!- 5 Cut In: 20 44- 5 Gas Supply Size 1/2" Sound Rating 79 79 80 80 I 81 81 • 1. Certified in accordance with A.H.R.I. Standard 210/240 at 95-F Outdoor DB and 80'F DB / 677 WB evaporator entering air at minimum external duct static pressures allowed by the standard 2. E.E.R. - Energy Efficiency Ratio (Btu/Watt). E.E.R. is determined @ 95T Outdoor DB & 80"F DB / 67*F WB Air Indoor S.E.E.R. - Seasonal Energy Efficiency Rating. A.F.U.E. - Annual Fuel Utilization Efficiency. AIRFLOW DATA Nominal Airflow Rates and Temperature Rises Model Number Max. Gas Supply Press. (in WC) Min. Gas Supply Press. (in.WC) MPress.anifold (in.WC) ' High Input (er) MO outomr) Low InOutputput (BtuMr) taw Output (swill Gas Rise Range (oF) Max Outlet TAirp Max. External Prrifice c ess. (in WC) Cooling Output Blower Rote Motor (HP) R8HE-X36C080X 10.0 4.5 3.5 80,000 76,000 52,000 49,400 45 35-65 165 0.80 36,000 11"x 8" 1 R8HE-X36D080X 10.0 4.5 3.5 80,000 76,000 52,000 49,400 45 35-65 165 0.80 36,000 11"x 8' 1 R8HE-X48C096X 10.0 4.5 3.5 96,000 91.200 62,400 59,300 45 40-70 170 0.80 47,000 11"x 10" 1 RBHE-X480096X 10.0 4.5 3.5 96,000 91,200 62,400 59,300 45 40-70 170 0.80 47,000 11"x 10" 1 R8HE-X60C096X 10.0 4.5 3.5 96,000 91,200 62,400 59,300 45 40-70 170 0.80 56,000 11"x 10" 1 RBHE-X600096X 10.0 4.5 3.5 _ 96,000 _ 91,200 62,400 59,300 45 40-70 _ 170 __ 0.80 56,000 11'x10' 1 4 AIRFLOW DATA CONTINUED SWITCH SETTING 5 0 1 6 0 0 7 0 0 8 0 0 1 0 1 0 0 1 0 0 1 0 1 0 0 1 1 0 1 1 1 0 0 0 0 1 0 0 1 0 1 0 1 1 0 1 0 0 1 1 1 0 1 1 0 1 1 1 1 1 1 1 RECOMMENDED AIRFLOW (CFM) 800 875 125_ 1000 1075 SWITCH SETTING 5 0 1 0 1 0 6 0 0 1 0 7 0 0 0 0 1 8 0 0 0 0 0 1125 1 0 1 -0. 1175 0 1 1 0 1225 1 1 1 0 RECOMMENDED AIRFLOW (CFM) 800 875 925 1000 1075 1125 1175 1225 1300 0 0 0 1 1350 1 0 0 1 1400 0 1 0 1 1450 1 1 0 1 1500 0 0 1 1 1525 1 0 1 1 1560 0 1 1 1 1600 1 1 1 1 1300 1350 1400 1450 1500 1525 1560 1600 SWITCH SETTING 5 0 1 0 .1. 6 0 0 1 1. 7 0 0 0 0 8 0 0 0 0 0 0 1 0 0 1 0 0 1 1 0 1 1 1 0 0 0 0 1 0 0 0 1 1 1 0 0 1 1 0 0 1 1 1 0 1 1 0 1 1 1 1 1 1 1 RECOMMENDED AIRFLOW (CFM) 1110 1145 1180 1250 1285 1320 1355 1390 1430 1480 1525 SWITCH SETTING 5 0 1 0 1 0 0 1 0 1 0 1 6 7 0 0 1 1 0 1 1 0 0 1 1 0 0 0 0 1 1 1 0 0 0 0 8 0 0 0 0 0 :0: 0 0 1 1 1 1575 0 0 1 1 1625 1 0 1 1 1675 0 1 1 1 1725 1 1 1 1 RECOMMENDED AIRFLOW (CFM) 1180 1250 1320 1380 1440 1500 1560 1610 1660 1710 1740 1770 1800 1830 1860 1895 SWITCH SETTING 5 6 7 8 RECOMMENDED AIRFLOW (CFM) SWITCH SETTING 5 6 7 8 RECOMMENDED AIRFLOW (CFM) 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 0 0 1 1 0 0 1 0 0 1 1 0 0 1 0 0 0 0 1 1 1 0 0 0 0 1 1 1 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1180 1250 1320 1380 1440 1500 1560 `"1610i, 1660 1710 1740 1770 1800 1830 1860 1895 0 1 0 0 0 0 0 0 0 0 1 0 1 0 0 1 0 1 0 1 1 1 0 0 1 0 1 1 0 0 1 1 0 0 1 1 1 1 0 0 0 1 1 1 1 0 0 0 0 0 0 1 1 1 1 1 1 1 1180 1250 1320 1380 1440 NOTE: Factory settings & recommended operating range are highlighted in bold / italics. Table 1. Cooling Airflow Settings 1500 1560 1610 1660 1740 1770 1800 1830 1860 1895 SWITCH SETTING SWITCH SETTING LOW HEAT HIGH HEAT LOW HEAT HIGH HEAT 39,000 60,000 52,000 80,000 1 0 1 0 844 41 1125 47 1 0 1 0 1125 43 1500 51 1 1 1 0 919 37 1225 43 1 1 1 0 1208 41 1610 47 0 0 0 1 975 35 1300 40 0 0 0 1 1245 40 1660 45 1 0 0 1 1013 34 1350 39 1 0 0 1 1283 39 1710 44 SWITCH SETTING SWITCH SETTING LOW HEAT HIGH HEAT LOW HEAT HIGH HEAT 52,000 80,000 62,400 96,000 I 2 3 4 CFM RISE CRA RISE 1 2 3 4 CFM RISE CFM RISE 1 1 0 0 911 50 1215 58 1 1 0 0 1035 53 1380 65 0 0 1 0 938 49 1250 56 0 0 1 0 1080 51 1440 63 0 0 1 1 1181 39 1575 45 0 0 1 1 1350 41 1800 51 NOTES: Factory settings are bold / italicized. Use of any other switch setting may result in nuisance trips and should be verified for the application. 2. Temperature rises in tables are approximate. Actual ternperature rises may vary 3. Shaded areas are not approved for proper operation of equipment. Table 2. Heating Airflow Settings EXPANDED RATINGS R8HE-X36(C,D O.D.T 65'F 75°F 85°F 95'F 105*F 115°F CFM E.D.B. E.W.B. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. 1050 80 62 38.3 31.8 2.16 36.7 31.3 2.35 34.7 30.5 2.58 32.3 29.5 2.88 29.5 28.3 3.22 262 262 3.61 80 67 38.7 23.6 2.18 372 22.9 2.36 35.3 22.0 2.60 32.9 20.9 2.90 302 19.8 324 27.0 18.1 3.63 80 72 442 21.5 2.19 42.7 20.7 2.38 40.9 19.6 2.62 38.6 18.4 2.92 35.9 17.0 3.26 32.8 15.4 3.65 75 62 37.1 28.3 2.12 35.9 27.5 2.32 34.3 26.5 2.56 322 25.4 2.87 29.8 24.0 3.22 26.9 22.5 3.62 1200 80 62 41.3 36.3 225 39.7 35.7 2.44 37.7 34.9 2.68 35.3 33.9 2.97 32.5 32.5 3.31 292 29.2 3.70 80 67 41.7 28.0 227 402 27.3 2.46 38.3 26.4 2.70 35.9 25.3 ;, 2.99 332 24.0 3.33 30.0 22.5 3.72 80 72 472 25.9 2.28 45.7 25.1 2.47 43.9 24.1 2.71 41.6 22.8 3.01 38.9 21.4 3.35 35.8 19.8 3.74 75 62 40.1 32.7 221 38.9 31.9 2.41 37.3 31.0 2.66 352 29.8 2.96 32.8 28.5 3.31 29.9 26.9 3.71 1350 80 62 38.9 33.6 2.37 37.3 33.0 2.56 35.3 322 2.80 32.9 312 3.09 30.1 30.1 3.43 26.8 26.8 3.83 80 67 39.4 25.3 2.39 37.8 24.6 2.58 35.9 23.7 2.82 33.6 22.6 3.11 30.8 21.3 3.45 27.6 19.8 3.85 80 72 44.8 232 2.41 43.4 22.4 2.60 41.5 21.4 2.84 39.2 20.1 3.13 36.5 18.7 3.47 33.4 17.1 3.87 75 62 37.7 30.0 2.33 36.5 29.2 2.53 34.9 28.3 2.78 32.9 27.1 3.08 30.4 25.8 3.43 27.6 24.2 3.84 R8HE-X48(C.D O.D.T 65°F 75°F 85^F 95°F ~ 105°F 115°F CFM E.D.B. E.W.B. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. KW. T.C. S.C. KW. T.C. S.C. KW. 1400 80 62 51.1 43.4 2.84 48.7 41.6 3.14 45.9 39.7 3.50 42.7 37.7 3.91 392 35.6 4.39 35.4 33.4 4.92 80 67 57.4 37.5 2.92 54.7 35.7 3.22 51.6 33.9 3.58 482 32.0 4.00 44.4 29.9 4.47 40.3 27.7 5.01 80 72 61.6 29.7 2.89 58.6 28.0 3.19 552 26.3 3.56 51.5 24.4 3.98 47.5 22.4 4.46 43.1 20.3 4.99 75 62 50.0 36.8 2.80 47.5 35.0 3.10 44.7 332 3.48 41.6 312 3.88 38.1 29.0 4.35 34.3 26.8 4.89 1550 80 62 50.1 442 2.94 47.6 42A 324 44.8 40.5 3S9 41.7 38.5 4.01 38.2 38.4 4.49 34.3 34.2 5.02 80 67 56.3 38.3 3.01 53.6 38.6 3.32 50.5 34.7 3.68 471 -�32.8 4.10:_, 43.4 30.7 4.57 39.3 28.6 5.11 80 72 60.5 30.5 2.99 57.5 28.8 329 54.1 27.1 3.65 50.5 252 4.08 46.4 232 4.55 42.1 21.1 5.09 , 75 62 48.9 37.6 2.90 46.5 35.8 320 ` 43.7 34.0 3.56 40.5 32.0 3.98 37.0 29.8 4.45 33.2 27.6 4.98 1700 80 62 52.6 45.7 3.10 502 44.0 3.40 47.4 42.1 3.76 442 40.1 4.18 40.8 37.9 4.65 36.9 35.7 5.18 80 67 58.9 39.8 3.18 562 38.1 - 3.48 53.1 . 36.3 3.84 49.7 34.3426 46.0 32.3 4.74 41.9 30.1 5.27 80 72 63.1 32.0 3.15 80.1 30.4 3.48 56.7 28.6 3.82 53.0 26.7 424 49.0 24.7 4.72 44.7 22.6 5.25 75 62 51.5 392 3.07 49.0 37.4 3.37 462 35.5 3.72 43.1 33.5 4.14 39.6 31.4 4.62 35.8 292 5.15 R8HE-X60(C,D O.D.T ...._.._._._ . . 65'F 75°F ........ 65°F 9 °F . :: .105°F 115°F: CFM E.D.B. E.W.B. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. T.C. S.C. K.W. 1500 80 62 60.6 49.5 3.44 57.6 47.8 3.78 542 46.1 4.20 50.6 , 442 4.69 46.7 42.3 527 42.6 40.3 5.93 80 67 67.5 42.2 3.52 64.0 40.3 3.85 60.2 38.4 4.26 562 36.3 4.75 51.9 342 5.32 47.3 32.0 5.97 80 72 74.1 34.6 3.57 702 32.5 3.89 66.0 30.3 4.29 61.5 28.1 4.78 56.8 25.7 5.34 51.7 23.3 5.99 75 62 65.9 47.1 3.07 61.6 44.4 3.48 57.0 41.6 3.98 522 38.7 4.55 47.0 35.8 521 41.6 32.8 5.95 1700 80 62 61.7 52.6 3.60 58.7 50.9 3.94 55.3 49.1 4.36 51.7 472 4.85 47.8 45.3 5.43 43.7 43.3 6.09 80 67 68.6 45.3 3.68 65.1 43.4 4.01 61.3 41.4 4.42 57.3 39.3 491 53.0 372 5.48 48.4 35.0 6.13 80 72 75.2 37.7 3.73 712 35.6 4.05 67.1 33.4 4.45 62.6 31.1 4.94 57.9 28.8 5.50 52.8 26.4 6.14 75 62 67.0 502 323 62.7 47.4 3.64 58.1 44.6 4.14 53.3 41.8 4.71 48.1 38.8 5.37 42.7 35.8 6.11 1900 80 62 61.9 53.1 3.88 58.8 51.4 4.21 55.5 49.6 4.63 51.9 47.7 5.13 48.0 45.8 5.71 43.8 43.8 6.36 80 67 68.7 45.8 3.95 652 43.9 428 61.5 41.9 4.69 57.4 39.8 5.18 53.1 37.7 5.75 48.5 35.5 6.40 80 72 75.3 38.2 4.00 71.4 36.1 4.33 672 33.9 4.73 62.7 31.6 521 58.0 29.3 5.78 53.0 26.9 6.42 75 62 67.1 50.7 3.50 62.8 48.0 3.92 58.3 452 4.41 53.4 42.3 _ 4.99 48.3 39.3 5.65 42.9 36.3 6.38 - 6 R8HE ACCESSORIES Description Part Number Cap, Duct Adapter, 12" Round 913811A Cap, Duct Adapter, 14" Round 913812A U.S. - LP Gas/High Elevation Conversion Kit (0-10,000 ft. above sea level) 922311 Canada - LP Gas/High Elevation Conversion Kit (0 - 4,500 ft. above sea level) 922312 Skirt Trim Kit 919729 Kit, Horizontal Vent Drain, R8HE 922323 Kit, Downflow Vent Drain, R8HE 922485 Roof Curb (8") 547830 Roof Curb (14") 547831 Roof Curb (18") 547850 Roof Curb (24") 547851 Cap, Duct Adapter, 12" Round 913811 A Cap, Duct Adapter, 14" Round 913812A Supply/return transition, 16" 547834 Supply/return transition, 18" 547835 Concentric diffuser, flush, 16" 547836 Concentric diffuser, flush, 18" 547837 Concentric diffuser, step down 16" 547838 Concentric diffuser, step down 18" 547839 Manual Fresh Air Damper 547832 Motorized Fresh Air Damper 547840 Economizer, Downflow, Modulating w/filter (does not require filter kit) 3 Ton 547833 Economizer, Downflow, Modulating w/fifter (does not require filter kit) 4, 5 Ton 558870 Economizer, Horizontal, Modulating 2 - 5 Ton 547841 Power Exhaust, Downflow (application requires downflow economizer) (Special Order) 547842 Power Exhaust, Horizontal (application requires horizontal economizer) (Special Order) 547843 Hood Type Hail Guard, Coil Dim. 30" X 76" 2, 2.5, 3 Ton 547844 Hood Type Hail Guard, Coil Dim. 34" X 76" 3.5 - 4 Ton 547846 Hood Type Hail Guard, Coil Dim. 38" X 76" 5 Ton 547847 DUCT SMOKE DETECTOR PHOTO ELEC 558863 MULTI SIGNAL CONTROL 558866 SAMPLING TUBE DST3, 2-4ft 558864 SAMPLING TUBE DST5, 4-8ft 558865 Low Ambient Kit 918837 Outdoor Thermostat Kit 913852 Extreme High Wind Kit - Roof Curb Mount 903696 Extreme High Wind Kit - Ground Mount 903695 Freezestat Kit 917108 Control, CO2 Sensor 547848 7 EX is+il (An 11' REVIEWED FOR CODE COMPLIANCE APPROVED YORK" Guide Specification for York Sunline AUG lae.'014 REFRIGERANT COMPONENTS Compressors: � ME COPY a. Shall be internally protect6d�with internal high- pressure relief and over pipporatak won. b. Shall have internal spring isolation and sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, independent mounting. Coils: a. Evaporator coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed. Special Phenolic coating shall be available as a factory option. b. Evaporator coils shall be of the direct expansion, draw-thru design. c. Condenser coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed or Micro -Channel aluminum tube, aluminum fins. d. Condenser coils shall be of the direct expansion, draw-thru design. Refrigerant Circuit and Refrigerant Safety Components shall include: a. Independent fixed -orifice or thermally operated expansion devices. b. Filter drier/strainer to eliminate any moisture or foreign matter. c. Accessible service gage connections on both suction and liquid lines to charge, evacuate, and measure refrigerant pressure during any necessary servicing or troubleshooting, without losing charge. d. The refrigeration system shall provide at least 15°F of sub -cooling at design conditions. Unit Controls: a. Unit shall be complete with self-contained low -voltage control circuit protected by a resettable circuit breaker on the 24-volt transfuruser side. b. Unit shall incorporate a lockout circuit which provides reset capability at the space thermostat or base unit, should any of the following standard safety devices trip and shut off compressor. c. Loss-of-charge/Low-pressure switch. d. High-pressure switch. e. Freeze -protection thermostat, evaporator coil f. Unit shall incorporate `AUTO R: ET' eityreignikwila over temperature, over current •, ii ING DIV SIGN g• j• Unit shall operate with conventional thermostat designs and have a low voltage terminal strip for easy hook-up. h. Unit control board shall have on -board diagnostics and fault code display. i. Standard controls shall include anti -short cycle and tow voltage protection, and permit cooling operation down to 0°F Control board shall monitor each refrigerant safety switch independently. k. Control board shall retain last 5 fault codes in non volatile memory which will not be lost in the event of a power loss. GAS HEATING SECTION (SINGLE STAGE) Shall be designed with induced draft combustion with post purge logic, energy saving direct spark ignition, and redundant main gas valve. Venter wheel shalt be constructed of stainless steel for corrosion resistance. The heat exchanger shall be of the tubular type, constructed of T1-40 aluminized steel for corrosion resistance and allowing minimum mixed air entering temperature of 25°F. Burners shall be of the inshot type, constructed of aluminum coated steel and contain air mixture adjustments. All gas piping shall enter the unit cabinet at a single location through either the side or curb without any field modifications. Integrated control boards shall provide timed control of evaporator fan functioning and burner ignition. Heating section shall be provided with the following minimum protection. a. Primary and auxiliary high -temperature limit switches. b. Induced draft motor speed sensor. c. Flame roll out switch. d. Flame proving controls. e. If any of the above safety devices trip, a LED (light - emitting diode) indicator shall flash a diagnostic code that indicates which safety switch has tripped. NOTE: Alt 2 Stage Gas Heat, 60% Capacity 1st Stage, 40% Capacity 2nd Stage. UNIT OPERATING CHARACTERISTICS Unit shall be capable of starting and running at 125°F outdoor temperature, exceeding maximum load criteria of AHRI Standard 210/240. The compressor, with standard controls, shall be capable of operation down to 0°F outdoor temperature. Unit shall be provided with fan time delay to prevent cold air delivery before heat exchanger warms up (Gas heat only). Unitary Sates Toot v1S9.0 hfama6ae is a&d jed to change without notice. Check local codes. M LfOl5O RECEIVED CITY OF TUKWILA P,irfed 07212D14 JUL 2 3 2014 PERMIT CENTER YORK® Guide Specification for York Sunline Page: 12 GENERAL Units shall be manufactured by Johnson Controls Unitary Products in an ISO 9001 certified facility. York Sunline units are convertible single package units. Although the units are primarily designed for curb mounting on a roof, they can also be slab -mounted at ground level or set on steel beams above a finished roof. Cooling only, cooling with gas heat and cooling with electric heat models are available with a wide variety of factory -mounted options and field -installed accessories to make them suitable for almost every application. Ail units are self-contained and assembled on full perimeter base rails with holes in the four comers for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to simplify the field installation and to provide years of dependable operation. Alt models (induding those with an economizer) are suitable for either bottom or horizontal duct connections. Models with power exhaust are suitable for bottom duct connections only. For bottom duct, remove the sheet metal panels from the supply and return air openings through the base of the unit. For horizontal duct, remove the supply and return air panels on the rear of the unit All non -Scroll compressors include crankcase heaters and all compressors have internal pressure relief. Every refrigerant circuit includes a liquid line filter -drier, a discharge line high pressure switch and a suction tine with a freezestat and low pressure/loss of charge switch. The unit control circuit includes a 75 VA transformer, a 24•volt circuit breaker and a relay board with a compressor lockout circuit, a terminal strip for thermostat wiring, plus an additional set of pin connectors to simplify the interface of additional field controls. All models are CSA listed. All models include a 1-year limited warranty on the complete unit. Compressors and electric heater elements carry a 5- year warranty. Aluminized steel and Stainless steel tubular heat exchangers carry a 10-year warranty. DESCRIPTION Units shall be factory -assembled, single packaged, Electric Cooling/Gas Heat, Electric Cooling/Optional Electric Heat, Heat Pump/Optional Electric Heat are designed for outdoor mounted installation. The 3 ton, 4 ton and 5 ton units shaft have minimum SEER rating of 13.0 with heat pumps having a 7.7 H.S.P.F. The 6 Ton Cooling only or Cooling with Electric Heat shall have 11.2 EER, 6 Ton Cooling with Gas Heat shall have 11.0 EER. They shall have built-in field convertible duct connections for down discharge supply/retum or horizontal discharge supply/return, and be available with factory installed options or field installed accessories. The units shall be factory wired, piped, charged with R-410A refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. All units the cooling performance shall be rated in accordance with DOE and AHRI test procedures. Units shall be CSA listed, classified to ANSi Z21.47, UL 19951CSA No. 236 standards. UNIT CABINET Unit cabinet shall be constructed of galvanized steel, with exterior surfaces coated with a non -chalking, powdered paint finish, certified at 1000 hours salt spray test per ASTMB117 standards. Indoor blower section shad be insulated with a minimum 1/2" thick insulation, coated on the airside. Aluminum foil faced insulation shall be used in the furnace compartment and be fastened with ridged fasteners to prevent insulation from entering the air stream. Cabinet panels shall be "large" size, easily removable for servicing and maintenance. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging and proper seating on roof curb applications. Disposable 1" filters shall be furnished and be accessible through a removable access door, sealed airtight Units filter track shall be designed to accommodate either 1" or 2" filters. Fan performance measuring ports shall be provided on the outside of the cabinet to allow accurate air measurements of evaporator fan performance without removing panels or creating air by-pass of the coils. Condensate pan shall be intemalty sloped and conform to ASHRAE 62-89 self -draining standards. Condensate connection shall be a minimum of 3/4" I.D. female and be a ridged mount connection. INDOOR (EVAPORATOR) FAN ASSEMBLY The indoor fan shall be a factory installed direct -drive or belt -drive assembly that includes an adjustable pitch motor pulley. Job site selected (B.H.P) brake horsepower shall not exceed the motors nameplate horsepower rating, plus the service factor. Units shall be designed not to operate above service factor. Fan wheel shall be double -inlet type with forward -curved blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant air volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. OUTDOOR (CONDENSER) FAN ASSEMBLY The outdoor fan shall be of the direct -driven propeller type, discharge air vertically, have aluminum blades riveted to a corrosion resistant steel spider bracket and shall be dynamically balanced for smooth operation. The outdoor fan motor shalt be totally enclosed with permanently lubricated bearings, Internally protected against overload conditions and staged independently. Unitary Sales Tool v1.5.8.0 hematite is subject to charge velthaut notice. check local codes Printed 07t21r2014 Small Sunline Single Package R.410A Air Conditioner Page: 8 Project Name: Quantity: CONTACTOR '4713 ? v 4- GROUND LUG Typical Field Pourer and Control Wiring TYPICAL POWER WIRING FIELD -SUPPLIED DISCONNECT r r----: SINGLE -i - 1 --a _' S3--r- PHASE J_-'Y 0-I-- POWER i L SUPPLY REFER -ORE -i C-R,CAi_ DATA GROUND 1. TASFS TO R-27 THE rSCON%ECT LUG S,.W. CH.'OYERCURRE'T PROTECTION: 1,10 1Rl { Unit Model a: ZFOSON10A2AAA2 System: ZF060N10A2AAA2 CONTACTOR FIELD -SUPPLIED DISCONNECT r.� 1 -r- THREE -1- -O- L� - r -j PHASE F -O O.- > POWER SUPPLY TYPICAL COOUHEAT CONTROL WIRING COOLING ONLY (24 VOLT THERMOSTAT) THERMOSTAT UNIT TERMINAL TERMINALS STRIP TB1 24 VOLT TRANSFORMER '24 'VOLTT-ERMOSTAT. TOCC4.TRCL T-_-CO.OMEER ON 3=CCR D STAGE COC,UNG. -S= A 2 STAGE cOOLN G T-ERUOSTAT_ COOLING / HEATING (ELECTRONIC THERMOSTAT) MULTISTAGE THERMOSTAT1 TERMINALS ADO JUMPER ADO JUMPER RC RH Y1 UNIT TERMINAL STRIP TB1 24 VOLT —I TRANSFORMER R Y2 Y1 2- Y2 W2 li 3 wt .12 B V 1EDf LED 2 COW Ai FAIT LD i A2 T T OCC • IORUSENSOR IF USED ELECTRON C FROGRAt:R.YtELE THERMOSTAT T,P CAL .CORD STAGE COOL H 3 S. HOTREOL1 RED O14194 TE LESS ECOtgJN DER 2ECOND STAGE HEAT NN3 S ONLY REOL I MD ON LIFT TS 'W TH A T:':O STAGE ELECTR C HEATER OR 2 STAGE GAS HEAT = REt'0VE J'JL°FER '2 FRO& TER: NALa .: ;IJD 9 ON Jllk'PER PLUG CONNECTOR P. ON1R1TS WIN EMNJF.-':`ER.TEIBJ.N.LSAlAND A2PRO,DEAREAS' OUT-FUT TO'r1.7'E THE OUT DOOR ECONCW'iER DAt'PER2 WHEN THE THERNO" RTMTCHES TO THE SETBAM POST ON. COOLING / HEATING (24 VOLT THERMOSTAT) THERMOSTAT' TERMINALS UNIT TERMINAL STRIP TB1 ADD JUMPER 24 VOLT TRANSFORMER 24 VOLT T-ERMOSTAT. TO COI.TROL T- E 1-01 OF.WE_R ON T-E SECOND STAGE COOLING OR TO -AVE A 3=CTtIC -EAT ACC=SeOR, WIT- TWO STAGES O= -EAT_ ..S_ A 22 STAG= COOL AND -EAT T-= MoSTAT. COOLING / HEATING (ELECTRONIC THERMOSTAT) SINGLE STAGE THERMOSTAT' TERMINALS UNIT TERMINAL 24 VOLT TRANSFORMER ',ELECTRON C FROrARAF144 ELE THERMOSTAT TYP CAL TO camoi THE E:.OHDF4 DER OH ,MCOND STAGE COOL NG USE A 2 STAGE COOL At4D HEAT THERMOSTAT Unitary Sales Tool v1.5.13.0 Irtlmmayon Is subject to change 'without rages. Check Iarsl codes. Printed 07212014 1J-E7YORIC Small Sunline Single Package ft-410A Air Conditioner Page: 7 Project Name: Ural Model #: ZFO6ONIOA2AAA2 Quantity System: IFO6ONIOA2AAA2 Typical Application ROOF JACK INSTALLATION I ROOF CURB INSTALLATION HELD -SUPPLIED DISCONNECT SWITCH -fr<21 TO POWER SUPPLY T CONDENSATE TRAP coNTRot. troRING to INDOOR THERMOSTAT RETURN AIR DUCT SUPPLY AIR DUCT ROOF CURB STAB ON GROUND INSTALLATION .7. IA, S'•• •• - ".41+1111W.- "' ftir • _.. MANUAL . GAS SHUT-OFF ' VALVE TO GAS SUPPLY LINE Unitary Beim Tool v15.8.0 hirannsfion is subject to dome Without notice. Check bad codes. RIMS 04821/2014 YORK' Small Sunline Single Package R-410A Air Conditioner Page: 6 Project Name: quantity: ling Model #: ZFO6ONIOA2AAA2 System: ZFO6ON1OA2AAA2 GaslElectric IiACR breaker Eccncmi.:er hood Kncckcul fir side power erdry if Slide -in economiser Smoke detector 3`1" PVC female condensate draft ��� v� .,��' gas supply entry Nell drive a Direct drive kie:rer Component Lot Cations 20 Gauge aluminized steel tubular heat exchange - Electric heat ai essay lccalicn Pc-ver :enter meter with pest purge cycle GFCI icrnenien a cutlet Knockout fa side ccnird entry Simpticittr_ Lite'" ccnird beard Knockout for side • tigh efidency ccmpresscr highly ETcient �.i._ Enhenced Copper TubeiEnhanced Aluminum Fin licc-Channel Aluminum TubeiAbrndnurn Fin Condenser Full perimeter baserails with forklift stets and fitting holes unitary Salm Tool v1.5.8.0 ln(annabon f, xRtject to Menge wMout noes. Chock rood cones. PI1TVae 07/21/2014 PORK" Small Sunline Single Package R-410A Air Conditioner Page: 3 Project Name: .. Quantity: Ural Model ft: ZF0B0N10A2AAA2 System; ZFO6ON10A2AAA2 Cooling Performance Total capaaly 59.8 MBH Sensible capadty 45.3 MBH R-410A RefrigerantSeasonal Efficiencytype R-410A (at ARI) 13.00 SEER Ef idency (at ARI) 10.80 LEH Ambient DB temp. 95.0 °F Entering DB temp. 80.0 'F Entering WB temp. 87.0 °F Leaving DB temp. 59.0 °F Leaving WB temp. 57.6 °F Power input (w/o blower) 4.54 kW Sound power 82 dB(A) Gas Heating Performance Entering DB temp. 60 °F Heating output capacity (Max) 100 MBH Supply air 2CFM Heating input capacity (Max)10 1255 MBH Leaving DB temp. 46.3 Air temp. rise SSE 80.6 % AFUE 80.3 % Stages 1 Supply Air Blower Performance Supply air 2000 CFM Ext. static pressure 0.75 IVVG Blower speed 1103 RPM Duct location Bottom Motor rating 1.00 HP Actual required BHP 1.02 HP Power input 0.95 kW Elevation 0 it Drive type DIRECT Speed tap 5 Electrical Data Power supply 230-3-60 Unit min circuit ampacity 27.5 Amps Unit max over -current protedion 35 Amps Dimensions & Weight Hgt 33 in. Len 83 in. Wth 45 in. Weight with factory installed options 644 lbs. Clearances Right 24 In. Front 32 in. Back 12 in. Top 72 in. Bottom 0 in. Left 24 in. Note: Please refer to the tech glade for fisted ma>dmum static pressures c 5 Ton • York Units are M a u fadured at an ISO 9001 Registered Facility and Each Rooftop is Completely Computer -Rum Tested Prior to Shipment. Unit Features • Unit Cabinet Constructed of Powder Painted Steel. Certified At 1000 Hours Salt Spray Test (ASTM 8-117 Standards) • Through -the -Curb and Through -The -Base UbTty Connections • Eriher Supply and/or Return can be Field Converted from Vertical to Horizontal Configuration without Cutting Panels. • Full Perimeter Base Rails with Built in Rigging Capabities • Gatvanized Steel Drain Pan • Rec ipsw.dtirg Compressor • Single Stage Cooling • Solid Core Liquid Line Filter Driers • Microchannei Condenser Coal • 100 MBH Output Aluminized Steel, Single Stage Gas Nominal Heat • 1 HP Deed Drive Blower • Unit Ships wftn 1 • Throwaway Filters with a Standard Filter Rack That Wig Accept up to 2• Filters • Single Point Power Connection • Short Circuit Current 5kA RMS Symmetrical Standard Unit Controller. Simplicity Control Board • An Integrated Low -Ambient Control, Anti -Short Cycle Protection, Lead -Lag, Fan On and Fan off Delays, Low Voltage Protection, On -Board Diagnostic and Faurtt Code Display. • Safety Monitoring - Morritvna the Hlgh and Low -Pressure Switches, the Freezestats, the Gas Valve, if Applicable, and the Temperature Limit Switch on Gas and Electric Heat Units. The Unit Control Board will Atann on ignition Failures, Safety Lockouts and Repeated Limit Switch Trips. Warranty • One (1) Year Limited Warranty on tire Complete Unit • Five (5) Year Warranty - Compressors and Electric Heater Elements • Ten (10) Year Warranty - Ahrninized Steel Tubular Heat Exchangers Untlaty Sales Tad v1.5.8.0 rnronneson is subjedm dupe withoutnasce. Check focal codes. Printed 0T212014 ,o ., r':;fi © Small Sunline Page: 6 r !' Single Package R410A Air Conditioner Project Name: Unit Model #: ZFO6ONIOA2AAA2 Quantity: System: ZFOBON10A2AAA2 Consolidated Drawing NOTES: I, FOR OUTDOOR USE ONLY, U N OPERATING CENTER OF GRAVITY LOCATION 16ASE UNITI 4 POINT CORNER LOADS (LIS) (EASE OMIT) 2. WEIGHTS SHOWN ARE TOR COOLING ONLY UNITS. tONNA6E 1 7 WEIGHT IL6S1 (BASE UNIT) N Y A B C 0 3. MIN. CLEARANCES TO BE: RIGHT SIDE: 24 1609,81 3 2F 418 12121 33 1838.21 18.25 1463,61 114 1521 76 1351 III 1501 117 1141 LEFT SIDE: 24 1609,81 !LESS ECONOMIZER) 36 1914,41 1W)TR ECONOMIIER) 4 IF 541 (2451 31.60 1800,11 18,50 1469,11 138 1131 85 (391 122 1551 196 C891 FRONT: 24 1609,61 1000LIN0/ELECTRIC HEAT) 32 1812.81 (GAS HEAT) 5 IF 519 E2581 37 1919.81 IS 13811 105 1481 86 1391 110 1171 2081141 REAR: 12 (304,81 (LESS ECOMONIXERI 36 (914,41 1111110 ECONOMIZER OR FIXED DAMPER) 6 IF 640 1290) 31 1939.0) IS 13811 118 1541 96 1441 162 1871 214 11011 AIRIMOTORIZED 10P: 12 11828,81 .._ $1.62 $1 8— 3 10 515 12611 40 110161 20 15101 1St 1601 125 1111 155 (701 164 1141 BOTTOM: 0 101 4. FOR SMALLER SERVICE AND OPERATIONAL CLEARANCES DEPARTMENT. 231 w- 6.12 1151,51 4 IR 585 1265) 40 110161 20 (5061 114 t611 127 1581 ISO (721 111 1161 CONTACT TOUR APPLICATION ENGINEERING S. DOWNFLOW DUCTS DESIGNED TO BE ATTACHED TO ACCESSORY 7.25 MOUNTED SIDE SUPPLY, IT 1134,01 18,28 1481,11 4^ 5 IR 590 12681 40 110161 20 15081 135 1611 128 1581 119 1721 1401161 ROOF CURB ONLY, If UNIT IS IS RECOMMENDED THAT THE DUCTS ARE SUPPORTED BY ON ACCESSORY ROOT CURBS. 1.80 --�- w— 27.54 -- J XP $15 (2611 39 1140,61 20 I5061 IJS till 121 I551 151 I891 I48 1161 CROSS BRACES, AS DONE 6, SIDE DUCT FLANGES ARE 0.315' 122,21 NIGH. 145,81 NAVE FLANGES. 1699,61 4 KP 585 12651 19 1990,61 YO 15081 IJt 1621 124 I16) IS/ 1701 Iil I78) BOTTOM DUCTS DO NOT 1. MINIMUM CONDENSATION TRAP HEIGHT SHALL BE 1.5 TINES * REAR S KP 500 12681 39 1990,41 20 15081 118 1631 125 IS71 15$ 1101 I72 lTbl STATIC. THE LOWEST NEGATIVE 8. DIMENSIONS IN E 1 ARE IN MILLIMETERS OR KILOGRAMS. 0. OPTIONAL COIL GUARD GAS HEAT ECONOMIZER HOOD, DISCONNECT SWITCH, CONVENIENCE OUTLET, AND 1.51 OUTLET/INLET HOOD SHOWN. 1140,01 ' A 4 -5.89 1140,61 8 ® EXCEPT KP (HEAT PUMP) UNITS, r �{ _ f POKER WIRING BOTTOM ENTRY 17311.31 12,26 11.50 i 1292, 11 I' 1 (C Oft • ' 3.00 11. 0 I76,2) I292, U -OP DIRECTION OF AIRFLOW - -,_„I' _1_ ( ` ') 02.00150,81 ® CENTER OF GRAVITY / ptNR I L� RETURN I 19,08 4,00 1101,61� �®I444,51 \ I 01A II. ,11 1164.61 Ill ,............0.01111.0110111111111111111MMINIMINIMI-1 1 ' I200, 21 6,50 I16S,11 II 14.58 O O 11 11,50 1444,51 7,62 1114,31 1193,61 11.01 (281,01 1184,71 AS SUPPLY 80TTOM ENTRY G$1.50 138,11 K.O. 11.50 II44,51 11,82 1803,21 CONTROL WIRING BOTTOM ENTRY 0,88 122,21 ^— 32,09 1815,21 (0.50 112,11 OPT AT GAS VALVE OUTLET HOOD ® ECONOMIZER MOOD 0 1,87 X.O, (OPTIONAL 150,01 DISCONNECT SWITC COVER 1OPTIONAL) K VENT AIR (RAIN N IS VIEW) 0118US7104 AIR INLET HOOD FILTER ° _ • 1Sw __ _ _ EAST _ _ COMP�. -1011111111 ACCE 6 SLOWER R CONVENIENCE OUTLET SLOWER AL E66 ACCEfiS ° I`I 27,35 ACCI68 COVER (OPTIONAL) AC((I Mil t026s11 / I1f4,7) I r OSD.BB Le. I22,21 �'1 �� I UM Ill madn111•1111111111111••••••••• f96g01 4.38 t116,2) IN --� 14158 1471,9) 19,17 4,12 III2,31 1111,11 31.89 (810,01 AS SUPPLY ENTRY F61.6J 141,41 ® U,88 II139,81 OIL GUARD (OPTIONAL) 61011T SEW 11.75 119,11 1499,11 2.55 PVC FPT 164,71 COND. DRAIN 82.19 12087,61 POINT VOW LEFT VW Unitary Baba Tool v1.6.8.0 ntonnatbn )eau e o change W(thoul nol(Ce. Check loeal codes. City of Tukwila Department of Community Development July 30, 2014 ARCHIE TYSYACHUK 12515 224 AVE E BONNEY LAKE, WA 98391 RE: Correction Letter # 1 MECHANICAL Permit Application Number M14-0150 FINE DESIGNS - 16550 W VALLEY HWY Dear ARCHIE TYSYACHUK, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: FIRE - M DEPARTMENT: Al Metzler at 206-971-8718 if you have questions regarding these comments. • 1. Unable to locate the cfm ratings for the new RTU's anywhere in the submitted information. Therefore, it is not possible to determine if smoke shutdown is required. Provide required cfm rating information. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, '-0.-0 --A,a, Bill Rambo Permit Technician File No. M14-0150 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0150 PROJECT NAME: FINE DESIGNS SITE ADDRESS: 16550 W VALLEY HWY Original Plan Submittal X Response to Correction Letter # 1 DATE: 08/11/14 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works n Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 08/12/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 09/09/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg D Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0150 PROJECT NAME: FINE DESIGNS SITE ADDRESS: 16550 W VALLEY HWY X Original Plan Submittal Response to Correction Letter #_ DATE: 07/23/14 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: C Building Division II Public Works NAK 0111 'm Fire Prevention Structural n Planning Division Permit Coordinator is PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 07/24/14 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 08/21/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: -740-- 1" Departments issued corrections: Bldg ❑ Fire Ping ❑ PW ❑ Staff Initials: (44_ 12/18/2013 4 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: M 14-0150 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Fine Designs Project Address: 16550 W Valley Hwy Contact Person: Vw-k l j i �Lt� &jL14 v' hone Number: - 20 6 S- 0 S& (2( Summary of Revision: �•J 4-1AkddiAtk cFM Pao;v TWPOILIII 4 11 2014 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: ®-- Entered in TRAKiT on \applications\forms-applications on line\revision submittal Created: 8-13-2004 Revised: BROTHERS HEATING LLC Page 1 of 2 Washington State Department of Labor & Industries BROTHERS HEATING LLC Owner or tradesperson Tysyachuk, Vitaliy Principals Tysyachuk, Vitaliy, PARTNER/MEMBER Tysyachuk, Alexandra I, PARTNER/MEMBER Doing business as BROTHERS HEATING LLC WA UBI No. 602 989 584 12515 224TH AVE E BONNEY LAKE, WA98391 253-862-0000 PIERCE County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties Heating/Vent/Air-Conditioning and Refrig (HVAC/R) License no. BROTHHL878RC Effective — expiration 12/03/2013-12/03/2015 Bond Platte River Ins Co Bond account no. 41272870 Received by L&I 12/03/2013 Insurance Underwriters at Lloyds Policy no. pfk048890 Received by L&I 12/03/2013 Active. Meets current requirements. $6,000.00 Effective date 11/18/2013 Expiration date Until Canceled $1,000,000.00 Effective date 11/18/2013 Expiration date 11/18/2014 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602989584&LIC=BROTHHL878RC&SAW= 08/19/2014