Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M14-0153 - CROWN CORK & SEAL - HVAC UNIT REPLACEMENT AND GAS PACK UNIT
CROWN CORK & SEAL 18340 SEGALE PARK B DR M14-0153 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 3523049119 Permit Number: M14-0153 18340 SEGALE PARK B DR Project Name: CROWN CORK & SEAL Issue Date: 10/9/2014 Permit Expires On: 4/7/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: SEGALE PROPERTIES LLC PO BOX 88028 , TUKWILA, WA, 98138 JOHN WARE 109 WASHINGTON BLVD, STE B, ALGONA, WA, 98001 FIVE STAR MECHANICAL 4210 B ST NW SUITE F , AUBURN, WA, 98001 License No: FIVESM*006C3 Expiration Date: 2/23/2016 Lender: Name: Address: Phone: (253) 852-8284 ,,, Phone: (253) 833-8284 DESCRIPTION OF WORK: REMOVE AND REPLACE AN OLD ELECTRIC HVAC UNIT AND INSTALL A NEW GAS PACK UNIT Valuation of Work: $17,000.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $415.74 Electrical Service Provided by: PUGET SOUND ENERGY Water District: HIGHLINE Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2014 2012 Permit Center Authorized Signature: Date: V I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signatu Print Nam Z>. This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL a separate permit the job site at the issued by the City of time of inspection. CITY OF TUKH 4 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 littp://www.TtikwilaWA.gov Mechanical IIvrmit No. L ` `[ I —Q ( Project No. Date Application Accepted: Date Application Application Expires: ` (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: Tenant Name: s3cio ,e_0/204- Crcruuvv Cort,4_ Kin Co Assessor's Tax No.: je Number: Floor: PROPERTY OWNER Name: t Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: 1 , ape__ .$)6\ Address: 1 0 l G�J 1 n•] .) I V CJ City: I l U VV4 State: \ , i' Zip: w Phone: Fax: Email: New Tenant: ❑ Yes X. No MECHANICAL CONTRACTOR INFORMATION Company Name: ),� (ili` fj t Address: 1aq %„- ,s�.\I�k t1)�Q c.( - D V_ City: 15 OVt� State: t i Zip:vez / t�J Phone: �153 S52 _ 2g y Fax: "Contr Reg No.: — Exp Dater 2a!Q�/ / Tukwila Business License No.: O99 2, 7 FSvf�SQTT Valuation of project (contractor's bid price): $ 0 O 0 - 0 v Describe the scope of work in detail: t,<-Q, w'__ ?n {� V 14-c (,t ln-lr - oIa( / i1lck paces Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement ) Fuel Type: Electric ❑ Gas Other: H:\Applications\Porms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <1 OOk btu Furnace > l 00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfrn Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Signa O; AU H! :IZ Date: / Y Print Name: — a.,r-2_ Day Telephone: Mailing Address: 1 01 Ttfv.„ TC `f ok 0/— a'osc)( City State Zip H:Wpplications\Forms-Applications On Line\2011 ApplicationsWlechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 DESCRIPTIONS PermitTRAK Cash Register Receipt City of Tukwila ACCOUNT QUANTITY PAID 335. 14-0153 Address: 18340 SEGALE PARK B DR Apn: 3523049119 335' MECHANICAL $319.80 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $287.30 TECHNOLOGY FEE $15.99 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R3269 R000.322.900.04.00 0.00 $15.99 $335.79 Date Paid: Thursday, October 09, 2014 Paid By: FIVE STAR MECHANICAL Pay Method: CHECK 41723 Printed: Thursday, October 09, 2014 1:21 PM 1 of 1 CRIVSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK 79:9C .......................................... M 14-0153 Address: 18340 SEGALE PARK B DR pn: 352304911 7995 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R2680 R000.322.102.00.00 0.00 $79.95 $79.95 $79.95 Date Paid: Friday, July 25, 2014 Paid By: JOHN WARE WARE ENTERPRISES Pay Method: CREDIT CARD 315271 Printed: Friday, July 25, 2014 11:18 AM 1 of 1 CRWSYSTEMS INSPECTION RECORD Retain a copy with permit 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431-2451 fV S' —ThS3 INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION C/) (206) 431-3670 Project: C^T tkh\/ 6oJk 5.eAL Type,of Inspection: I<00/ft -r�J4L Address:7� 1.._WO 5. .6 L -- Date}Called; _ _. /tC�'6i.6(4-(.n/A. Special Instructions: // S twv\c. ( ' ' f r , Date Wanted: a.m. / dO . 2 ?. ` / 4 hr.m Requester: Pho (e�No: c _ C;p i v Approved per applicable codes. DCorrections required prior to approval. COMMENTS: a eRm C. -cA l'1 4 Inspect t: Date:(O - - L — 4 REINSPECTI©N FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION No. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 0 Permit Inspection Request Line (206) 431-2451 Projje^ct: /� %/ �,, (� Type of Inspection: Address: A /5��j ✓ ! 34f S'PUM- Ark, Date Called: , Special Instructions: �� 414k.4_ e /(r p-wK reV't _ srA& Date Wanted: , -rs-rat a.m. .. Requester: PMz 53 S 3 --- S Z-k4 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date 0 / T - /4 REINSPECTION FEE REQUIRED.(Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. T Crown Cork and Seal Unit Dimensions - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 June 12, 2014 EVAPORATOR SECTION ACCESS PANEL CONDENSATE DRAIN (ALT) 3/4"-14 NPT DIA. HOLE 4 1/4" 27 5/8" 47 7/8" 1/2" NPT GAS CONNECTION (80MBH & 120MBH) 3/4" NPT GAS CONNECTION (150MBH, 200MBH & 250MBH) THROUGH THE BASE CONDENSATE PLAN VIEW UNIT DIMENSION DRAWING SUPPLY 23 IRETURN 7/8" 1 9 00 00 32 1/4" TOP PANEL FILE COPY CONDENSER FAN CONDENSEF REVIEWED FOR CODE COMPLIANCE APPROVED COIL AUG 0 5 2014 City of Tukwila BUILDING DIVISION UNIT CONTROL WIRE 7/8" DIA. HOLE SERVICE GAUGE PORT ACCESS 1 3/8" DIA. HOLE UNIT POWER WIRE CONTROL AND COMPRESSOR ACCESS PANEL NOTES: 1. THRU -THE -BASE ELECTRICAL AND GAS IS NOT STANDARD ON ALL UNITS. 2. VERIFY WEIGHT, CONNECTION, AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION RECEIVED CITY OF TUKWILA JUL 2 5 2014 PERMIT CENTER 40 7/8" 181/2"Q 95/8"55/8" 4 3/4" b 19 1/4" CONDENSATE 88 5/8" 9 3/8" - 16 3/4" - - 3 7/8" PACKAGED GAS / ELECTRICAL 4 1/4"-- 5 5/8" 7 5/8" O 0 DIMENSION DRAWING 53 1/4" 1 HORIZONTAL AIR FLOW 1140153 FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 5 of 15 Installed by Others Crown Cork and Seal Unit Dimensions - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 June 12, 2014 3/4"-14 DIA HOLE CONDENSATE DRAIN 27 5/8" ISOMETRIC -PACKAGED COOLING 4 3/4" FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 6 of 15 Installed by Others Crown Cork and Seal Unit Dimensions - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 June 12, 2014 ELECTRICAL / GENERAL DATA 'GENERAL tzlta>te> Model: YHC048F Oversized Motor Unit Operating Voltage: 414-506F MCA: N/A Unit Primary Voltage: 460 MFS: N/A Unit Secondary Voltage — MCB: N/A Unit Hertz: 60 Unit Phase: 3 SEER 15 Standard Motor Field Installed Oversized Motor MCA: '12.8 MCA: N/A MFS: 15.0 MFS: N/A MCB: 15.0 MCB: N/A HEATING PERFORMANCE HEATING - GENERAL DATA Heating Model: 'Medium Heating Input (BTU): 80,000 Heating Output (BTU): 64,000 No. Burners: 2 No. Stages 1 'Gas Inlet Pressure Natural Gas (Min/Max): '4.5/14.5 LP (Min/Max) 11.0/14.0 Gas Pipe Connection Size: 1/2" INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number: '1 Number: N/A Number: N/A Horsepower: 1.0 Horsepower: N/A Horsepower: N/A Motor Speed (RPM): — Motor Speed (RPM): N/A Motor Speed (RPM): N/A Phase 1 Phase N A Phase N/A Full Load Amps: 7.6 Full Load Amps: N/A Full Load Amps: N/A Locked Rotor Amps: _ Locked Rotor Amps: N/A Locked Rotor Amps: N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number: '1 Number: '1 Horsepower: 3.5 Horsepower: 0.40 Phase: 3 Motor Speed (RPM): 1075 Rated Load Amps: 6.2 Phase: 1 Locked Rotor Amps: 41.0 Full Load Amps: 1.0 Locked Rotor Amps: 2.8 POWER EXHAUST ACCESSORY (3) FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type R-410 Phase: N/A Type: Throwaway Horsepower: N/A Furnished: Yes Factory Charge Motor Speed (RPM): N/A Number 4 Circuit #1 5.1 Full Load Amps: N/A Recommended 16"x25"x2" Circuit #2 N/A Locked Rotor Amps: N/A NOTES: 1. Maximum (HACR) Circuit Breaker sizing is for installations in the United States only. 2. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. 3. Value does not include Power Exhaust Accessory. 4. Value includes oversized motor. 5. Value does not include Power Exhaust Accessory. 6. EER is rated at AHRI conditions and in accordance with DOE test procedures. FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 7 of 15 Installed by Others Crown Cork and Seal Weight, Clearance & Rigging Diagram - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 June 12, 2014 PACKAGED GAS / ELECTRICAL CORNER WEIGHT INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 36.0 lb MOTORIZED OUTSIDE AIR DAMPER MANUAL OUTSIDE AIR DAMPER BAROMETRIC RELIEF OVERSIZED MOTOR BELT DRIVE MOTOR POWER EXHAUST THROUGHT THE BASE ELECTRICAL/GAS (FIOPS) UNIT MOUNTED CIRCUIT BREAKER (FIOPS) UNIT MOUNTED DISCONNECT (FIOPS) POWERED CONVENIENCE OUTLET (FIOPS) HINGED DOORS (FIOPS) HAIL GUARD SMOKE DETECTOR, SUPPLY / RETURN NOVAR CONTROL STAINLESS STEEL HEAT EXCHANGER REHEAT ROOF CURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET 226.0Ib © 144.0Ib (E) LENGHT (F) WIDTH 806.0 Ib 711.0 Ib 0 0 199.0 Ib 0 143.0 Ib 44" 22" NOTE: 1. CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2. TO ESTIMATE SHIPPING WEIGHT ADD 5 LBS TO NET WEIGHT. 3. BASIC UNIT WEIGHT DOES NOT INCLUDE ACCESSORY WEIGHT. TO OBTAIN TOTAL WEIGHT, ADD ACCESSORY NET WEIGHT TO BASIC UNIT WEIGHT. 4. WEIGHTS FOR OPTIONS NOT LISTED ARE <5 LBS. PACKAGED GAS / ELECTRICAL RIGGING AND CENTER OF GRAVITY FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 8 of 15 Installed by Others ' Crown Cork and Seal Weight, Clearance & Rigging Diagram - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 June 12, 2014 CLEARANCE 36" CLEARANCE 48" DOWNFLOW CLEARANCE 36" HORIZONTAL CLEARANCE 18" ROOF OPENING UNIT OUTLINE-. 1 CLEARANCE 36" PACKAGED GAS / ELECTRIC CLEARANCE 46" 88 5/8" 46" CLEARANCE FROM TOP OF UNIT 72" 53 1/4" PACKAGED GAS / ELECTRIC DOWNFLOW TYPICAL ROOF OPENING FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 9 of 15 Installed by Others Crown Cork and Seal Accessory - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 June 12, 2014 BAROMETRIC RELIEF HOOD 7 3/4" BAROMETRIC RELIEF HOOD ACCESSORY - BAROMETRIC RELIEF DAMPER HOOD ECONOMIZER HOOD FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 10 of 15 Installed by Others ' ' Crown Cork and Seal Accessory - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 June 12, 2014 ECONOMIZER HOOD 16 3/4" ACCESSORY - ECONOMIZER HOOD ECONOMIZER HOOD FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 11 of 15 Installed by Others AEI AIM Milk IN IOW MBE SHUTLER CONSULTING ENGINEERS, Inc. 12503 Bel -Red Road, Suite 100 Bellevue, Washington 98005 (425) 450-4075 FAX (425) 450-4076 JOB Crown Cork SHEET NO. COVER CALCULATED BY jch CHECKED BY SCALE JOB NUMBER 14-01.30 OF DATE 7/14/2014 DATE STRUCTURAL CALCULATIONS FOR: REPLACEMENT HVAC UNIT -- CROWN CORK & SEAL 18340 SEGALE PARK 'B' DRIVE TUKWILA, WASHINGTON PROPOSED BY: FIVE STAR MECHANICAL 109 WASHINGTON BLVD. ALGONA, WA 98001 (253) 852-8284 DESIGN CRITERIA: CODE ROOF LIVE LOAD WIND LOAD SEISMIC ZONE c. HE , W A sy�o '� G 31757 � Kc,c �F� ��NA L CODEEC ��/ED FOR APPROVED Q AUG 0 5 2014 Cp °f Tukwila LNG DIVISION John Headland 2014.07.14 10:03:25 -07'OO' INTERNATIONAL BUILDING CODE, 2012 EDITION 25 PSF SNOW LOAD, Is=1.0 110 MPH ZONE, EXPOSURE 'B', Iw=1.0 SITE CLASS 'D', Sds=0.955, ap=2.5, Rp=6.0, Ip=1.0 0153 RECEIVED CITY OF TUKWILA JUL 2 Fa 2014 PERMIT CENTER 0 SHUTLER ®® ' '' CONSULTING ®® !' `' ENGINEERS, INC 12503 Bel -Red Rd., Suite 100 Bellevue, WA 98005 (425) 450-4075 FAX (425) 450-4076 JOB SHEET NO. Jk6'1 OF CALCULATED BY Jai DATE SCALE _NMI MN SHUTLER CONSULTING ENGINEERS, INC 12503 Bel -Red Rd., Suite 100 Bellevue, WA 98005 (425) 450-4075 FAX (425) 450-4076 JOB Clite)W Cai SHEET NO. e5k g OF CALCULATED BY "` -644 DATE SCALE I I i I�+oirNK.ina6c�s.Yea.r1.r+r.rFMt!aw.uncar�Nle�:t ` fvdidli ..meiNev+tllM -.11..tl+u.�e.[ln+b o{sas.R..WPMO...* : r i ai i ! SHUTLER _I - CONSULTING MI MN ENGINEERS, INC 12503 Bel -Red Rd., Suite 100 Bellevue, WA 98005 (425) 450-4075 FAX (425) 450-4076 JOBC&kc 044 SHEET NO v OF CALCULATED BY NTH DATE SCALE -- _ SHUTLER CONSULTING __ ENGINEERS, INC 12503 Bel -Red Rd., Suite 100 Bellevue, WA 98005 (425) 450-4075 FAX (425) 450-4076 JOB C... Cdogk., SHEET NO. -4?' OF CALCULATED BY DATE % / NV) SCALE - SHUTLER JOB CattAka `-'"� _II- CONSULTING MEW Mill ENGINEERS, INC 12503 Bel -Red Rd., Suite 100 Bellevue, WA 98005 (425) 450-4075 FAX (425) 450-4076 SHEET NO. CALCULATED BY DATE SCALE III MIN SHUTLER ��- CONSULTING -_ ENGINEERS, INC 12503 Bel -Red Rd., Suite 100 Bellevue, WA 98005 (425) 450-4075 FAX (425) 450-4076 JOB C&)JL1 Gut/ SHEET NO. CALCULATED BY DATE SCALE Gam' Roof Top HVAC Unit - lateral loads Seismic - SdS 0.955 aP 2.5 Sd, 0.534 RP 6.0 IP 1.0 FP 0.478 wt Wind - Speed 110 mph Exposure B qZ 18.43 psf FP - ws 21.0 psf F„ - ws 16.6 psf KZ Kn Kd 0.70 1.00 0.85 1•.00 GCS - horiz. • . 1.90. GCS- vent. • 1.50 )esign Maps Swnmary Report USGS Design Maps Summary Report User -Specified Input Building Code Reference Document 2012 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.44°N, 122.26°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III USGS-Provided Output Ss = 1.432 g S1 = 0.534 g SMs = 1.432 g SM1 = 0.801 g Sus = 0.955 g Sul = 0.534 g East Renton For information on how the SS and Si values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. 1.65 1.50 1.35 1.20 1.05 0.90 M 0.75 0:60 0.45 0.30 0.1s 0.00 0.00 MCER Response Spectrum 0.20 0.40 0.60 0.90 1.00 1.20 1.40 1.60 1.20 Period, T (sec) 2.00 1.10 1.00 0.90 0.20 0.70 01 0.60 y 0.50 0.40 0.30 0.20 0.10 0.00 0.00 0.20 Design Response Spectrum 0.40 0.60 0.20 1.00 1.20 1.40 1. r,0 1.90 Period, T (sec) 2.00 Although this information Is a product of the U.S. Geological Survey, we provide no warranty, expressed or Implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. >f l 7/ 1 l /2014 3:30 PM 8340 segale park drive b, tukwila, wa - Google Maps rt 12!,!ii;:. • cr gk 1'' �`•'lf:�;'ISt ep14 Google >f l Q. g-a Address 18340 Segale Park B Dr Latitude 47.44 Tukwila, WA 98188 Longitude -122.26 :z 1 i3E,th SI t1 ''3tlltil it S I Oath Map data 02014 Googly 7/11/2014 3:29 PM . PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0153 DATE: 07/25/14 PROJECT NAME: CROWN CORK & SEAL SITE ADDRESS: 18340 SEGALE PARK B DR X Original Plan Submittal Revision # Response to Correction Letter # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works n C Z6i'ill Fire Prevention or Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 07/29/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required n (corrections entered in Reviews) DUE DATE: 08/26/14 Approved with ConditionsIgf Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 FIVE STAR MECHANICAL Page 1 of 2 0 Washington State Department of Labor & Industries FIVE STAR MECHANICAL Owner or tradesperson WARE, GERALD LAVON Principals WARE, GERALD LAVON, MEMBER WARE, JOHN EDWARD, MEMBER ALLEN, ANGELA RENEE, MEMBER WARE, BETTY J, MEMBER Doing business as FIVE STAR MECHANICAL WA UBI No. 601 937 083 109 WASHINGTON BLVD STE B ALGONA, WA98001 253-852-8284 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. FIVESM*010JT Effective — expiration 04/30/1999— 05/01/2016 Bond Western Surety Co Bond account no. 62031473 Received by L&I 05/16/2014 Bond history Insurance No current insurance account. See the insurance history. Insurance history Savings No savings accounts during the previous 6 year period. Active. Meets current requirements. $12,000.00 Effective date 04/27/2014 Expiration date Until Canceled https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601937083&LIC=FIVESM* 01 OJT&SAW= 10/09/2014 FIVE STAR MECHANICAL Lawsuits against the bond or savinL No lawsuits against the bond or savings accounts during the previous 6 year period. Page 2 of 2 L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 861,401-01 Doing business as FIVE STAR MECHANICAL Estimated workers reported Quarter 2 of Year 2014 "7 to 10 Workers" L&I account representative T3 / KENT ANDERSON (360)902-6963 - Email: ANDN235@Ini.wa.gov Account is current. Workplace safety and health No inspections during the previous 6 year period. © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Access «ra.sltiingionw .'M Gee rnment k4h Site https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601937083&LIC=FIVESM*010JT&SAW= 10/09/2014 G H J K 1 2 3 4 5 6 7 8 9 10 ENERGY NOTES (IN COMPLIANCE W/ 2012 WSEC ENERGY CODES) 1. MOTORS: SHALL COMPLY WITH MINIMUM LOAD EFFICIENCY LISTED IN THE ENERGY CODE ENFORCED BY THE AHJ (AUTHORITY HAVING JURISDICTION) 2. DUCT INSULATION: COMPLY WITH THICKNESSES AND TYPES LISTED IN THE ENERGY CODE FOR ANY NEW DUCT INSTALLED ENFORCED BY THE LOCAL AHJ, UNLESS MORE STRINGENT REQUIREMENTS ARE SPECIFIED. PROVIDE SCHEDULES IN DRAWINGS IF REQUIRED BY AHJ. 3. DUCT SEALING: SEAL ALL DUCT TRANSVERSE JOINTS AND LONGITUDINAL SEAMS PER ENERGY CODE ENFORCED BY THE LOCAL AHJ, UNLESS MORE STRINGENT REQUIREMENTS ARE SPECIFIED. 4. RECORD DRAWINGS: SUBMIT TO THE BUILDING OWNER PER ENERGY CODE ENFORCED BY THE LOCAL AHJ IF REQUIRED. 5. OPERATION AND MAINTENANCE MANUALS: SUBMIT TO THE BUILDING OWNER PER ENERGY CODE ENFORCED BY THE LOCAL AHJ. 6. SYSTEM BALANCING: BALANCE HVAC SYSTEMS AS REQUIRED. 7. MECHANICAL SYSTEMS COMMISSIONING AND COMPLETION REQUIREMENTS: TEST SYSTEMS TO ENSURE THAT BUILDING SYSTEMS HAVE BEEN DESIGNED AND INSTALLED, FUNCTION PROPERLY AND EFFICIENTLY, AND CAN BE MAINTAINED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS IN ORDER TO SATISFY THE DESIGNER'S DESIGN INTENT AND OPERATIONAL REQUIREMENTS PER ENERGY CODE ENFORCED BY THE LOCAL AHJ. 8. ALL WORK SHALL COMPLY WITH ENERGY CODES ENFORCED BY THE LOCAL AHJ. CONTRACTOR IS RESPONSIBLE FOR CORRECT INSTALLATION OF ENERGY CONSERVATION MEASURES. MECHANICAL VENTILATION SHALL BE APPLIED IN ACCORDANCE WITH 2012 WSEC. GENERAL SPECIFICATIONS SEPARATE PERMIT REQUIRED FOR: 0 Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION GENERAL: 1. CODE COMPLIANCE - ALL WORK SHALL COMPLY WITH ALL LOCAL CODES AND ORDINANCES. 2. DRAWINGS: DRAWINGS ARE DIAGRAMMATIC AND SHOW THE GENERAL ARRANGEMENT OF THE CONSTRUCTION AND THEREFORE DO NOT SHOW ALL NECESSARY OFFSETS, FITTINGS, AND ACCESSORIES WHICH ARE REQUIRED. 3. FIELD VERIFICATION: CHECK FIELD CONDITIONS AND VERIFY SPACE AVAILABLE FOR DUCTS BEFORE PROCEEDING WITH THE WORK (IF EXISTING BLDG, OR DURING CONSTRUCTION OF NEW). 4. WARRANTY: ALL WORK AND EQUIPMENT SHALL BE WARRANTED TO BE FREE FROM DEFECTS AND CAPABLE OF PROVIDING SATISFACTORY OPERATION FOR A PERIOD OF 1 YEAR AFTER FINAL ACCEPTANCE. 5. COMPLETE SYSTEMS: NOT ALL NECESSARY MATERIALS TO PERFORM THE WORK REQUIRED ARE SPECIFIED OR SHOWN. CONTRACTOR SHALL PROVIDE ALL ITEMS NEEDED TO HAVE COMPLETED PROPERLY OPERATING SYSTEMS. ITEMS PROVIDED SHALL BE OF COMMERCIAUINSTITUTIONAL QUALITY CONSISTENT WITH THE QUALITY OF RELATED ITEMS PROVIDED ON THE PROJECTOR CURRENTLY BEING USED IN THE BUILDING. 6. SEISMIC: ALL DUCTWORK AND EQUIPMENT SHALL BE INSTALLED AND BRACED FOR THE SEISMIC CATAGORY FOR THIS PROJECT PER CODE AND SMACNA "SEISMIC RESTRAINT MANUAL GUIDELINES FOR MECHANICAL SYSTEMS" LATEST EDITION. BUILDING IS NON-ESSENTIA, SEISMIC CATEGORY "D." CONDENSATE PIPING: 1. PIPE FITTINGS: POLYVINYL CHLORIDE (PVC) PIPE, SCHEDULE 40, PER ASTM D-1758. SOLVENT CEMENT SOCKET TYPE FITTINGS PER ASTM D-2466. SOLVENT CEMENT SHALL COMPLY WITH ASTM D-2564. 2. INSTALLATION: INSTALLATION SHALL COMPLY WITH LOCAL CODE, BEST PROFESSIONAL PRACTICES AND MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS. PROVIDE ALL PIPING AS REQUIRED AND AS REQUIRED FOR CONDENSATE AND MISCELLANEOUS HVAC EQUIPMENT CONDENSATE DRAINS, AND RUN PIPING FROM UNITS TO NEAREST POINT OF DRAINAGE ON THE (E) ROOF. HVAC ROOFTOP UNIT: 1. QUALITY ASSURANCE: UNIT SHALL BE UL LISTED AND LABELED AS SUCH. UNIT EFFICIENCY SHALL COMPLY WITH ALL UP TO DATE AND APPLICABLE CODES. 2. TYPE: SINGLE PACKAGED GAS -HEATING AND ELECTRIC AIR CONDITIONING UNIT - DOWN FLOW SUPPLY & BOTTOM OF UNIT RETURN AS INDICATED ON THE CONTRACT DOCUMENTS (DRAWINGS / SCHEDULES). 3.GENERAL: UNIT SHALL BE FULLY FACTORY ASSEMBLED AND SHALL BE COMPLETE WITH CASING COILS, FANS, COMPRESSORS, PIPING, WIRING, DISCONNECT CONTROLS, GAS BURNER, HEAT EXCHANGER AND ALL OTHER ACCESSORIES REQUIRED TO BE READY FOR FIELD CONNECTIONS AND OPERATION. UNITS SHALL BE UL LISTED AND LABELED AND BE DESIGNED FOR OUTDOOR APPLICATION. 4. FANS: EVAPORATOR FAN SHALL BE STATICALLY AND DYNAMICALLY BALANCED AT FACTORY. FAN SHALL BE FORWARD CURVE CENTRIFUGAL TYPE WITH MULTI -SPEED DIRECT DRIVE (OR BELT DRIVE) MOTOR. MOTOR SHALL BE PERMANENTLY LUBRICATED TYPE WITH BUILT IN AUTO RESET THERMAL OVERLOAD PROTECTION. BEARINGS SHALL BE SEALED, PERMANENTLY LUBRICATED BALL BEARING TYPE. CONDENSER FAN SHALL BE STATICALLY AND DYNAMICALLY BALANCED AT FACTORY, PROPELLER TYPE AND FAN SHALL BE DIRECT DRIVE WITH PERMANENTLY LUBRICATED COMPONENTS AND TOTALLY ENCLOSED WEATHER PROOF MOTOR HAVING BUILT IN AUTO RESET THERMAL OVERLOAD PROTECTION. 5. HEATING SECTION SHALL BE GAS FIRED TYPE WITH HEAT EXCHANGER TO PREVENT PRODUCTS OF COMBUSTION FROM COMING INTO CONTACT WITH HEATED SUPPLY AIR TO THE BUILDING. HEAT EXCHANGER SHALL BE CONSTRUCTED OF CORROSION RESISTANT STEEL. HEATER SHALL HAVE INDUCED DRAFT OR FORCED DRAFT FANS TO VENT PRODUCTS OF COMBUSTION. FAN SHALL BE INTERLOCKED TO UNITS GAS VALVE AND HEATING CONTROLS TO ALLOW PRE -PURGE OF UNIT PRIOR TO OPENING GAS VALVE AND ALLOWING COMBUSTION. IGNITION SHALL BE PILOTLESS, AND SHALL USE ELECTRONIC IGNITION OR HOT SURFACE IGNITION SYSTEM. 6, FILTERS: UNITS SHALL HAVE FILTER FRAME FOR HOLDING FILTER SIZES (OR FILTER FACE AREA) AS SCHEDULED ON THE PLANS, DWG MO.0 FILTERS SHALL BE MEDIUM EFFICIENCY, PLEATED PANEL, DISPOSABLE TYPE. FILTER MEDIA SHALL PROVIDE A MINIMUM OF MERV 8 EFFICIENCY WHEN EVALUATED UNDER ASHRAE 52,2. CAMIUFARR "30/30" (OR APPROVED EQUAL). 7, ELECTRICAL POWER: UNITS SHALL BE FOR USE WITH POWER OF 460V, 3 PH, 60 HZ, AS SCHEDULED ON THE PLANS PER DWG MO.0. RTU-1 SHALL HAVE SINGLE SOURCE POWER ENTRY, AND SHALL REQUIRE ONLY ONE FIELD CONNECTION AND POWER SOURCE (EXCEPT FOR SEPARATE POWER TO ECONOMIZER) ALL NECESSARY TERMINAL BLOCKS. FUSES, WIRING, JUNCTION BOXES, ETC. SHALL BE FACTORY INSTALLED WITHIN THE UNIT CABINET TO PROVIDE POWER TO ALL UNIT DEVICES REQUIRING POWER. 8. RTU- 1 SHALL BE INSTALLED ON THE (E) ROOF OF THE BUILDING AND ANCHORED SEISMICALLY PER ALL APPLICABLE CODES, STRUCTURAL ENGINEERING IS BY OTHERS. 9. START-UP: SUBSEQUENT SYSTEM CHECKS SHALL BE DONE FOLLOWING THE MANUFACTURERS WRITTEN START-UP PROCEDURES PRIOR TO OPERATING UNITS. FIELD CHECKLISTS SHALL BE MADE TO ENSURE THAT ALL EQUIPMENT, PIPING AND CONTROLS ARE CONNECTED AND OPERATING PROPERLY. REVISIONS No changes shall be r made to the scope of work without p approval f Tukwila Building Division_ NOTE: Revisions Will require a nsw plan submittal and may include additional plan review fees WORK SITE FILE COPY P ° molt No. W i t-i - Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and onditions apknowledged: Date: City of Tukwila BUILDING DIV VICINITY MAP SCALE: NONE SITE MAP SCALE: NONE MO.0 I Li-s,o REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 5 2014 City ©T kwila BUILD1N !VISION ROOF TOP UNIT SCHEDULE TAG MAKE / MODEL NOMINAL CAPACITY (TONS) SUPPLY AIR FLOW (CFM)LINE ESP (IN WG)PHYSICAL COOLING HEATING (GAS)ELECTRICAL NOMINAL UNIT SIZE (LWH, IN) GAS LINE SIZE CONDENSATE DRAIN SIZE RA FILTER TYPE RA FILTER QUANTITY RA FILTER SIZE DUCT ORIENTATION INDOOR MOTOR BHP WT (LBS} MIN OSA VENTILATION (CFM) SOUND LEVEL (DB) REMARKS GROSS TOTAL MBH SEER REFRIG- ERANT NO.OF CIRCUITS NO. &TYPE COMPRESSORS HP PH RLA LRA SYSTEM POWER INPUT (MBH) OUTPUT (MBH) VOLT / PH LOAD (MCA) LOAD (MOCP) RTU-1 TRANE YHC048F 4 1600 5 49.0 15.0 R-410A 1 1 / SCROLL 3.5 3 6.2 41.0 3.67 KW 80 64 460/3 12.8 15.0 88 5/8" X 53 1/4" X 40 7/8" 1/2' 3/4" THROWAWAY 4 16X25X2 DOWN 1.0 711 320 87.0 1, 2, 3, 4, & 5 C1 CITY 0 NOTES 1. ECONOMIZER OPERATION SHALL BE 0-100 PERCENT OSA. ECONOMIZERS SHALL BE IN COMPLIANCE W/ 2012 WSEC. 4. ADAPTER CURB: KCC INTERNATIONAL, DWG. # KCC-093, ADAPTER WT: S57 LBS, NEW UNIT: TRANE # YHC048F, ADAPT TO (E) UNIT# BWC060C-D. 5. RTU-1 SIZED, I.E. CAPACITY IN COOLING & HEATING REQUIREMENTS, BY OTHERS. 2. COOLING ENTERING DB 95.0 DEG F, EVAP ENTERING AIR DB; 80 DEG F, EVAP ENTERING WB, 67 DEG F, ENTERING AIR ENTHALPY 31.44 BTU/LB SEE STRUCTURAL FOR CURB TO UNIT & CURB TO ROOF FASTENING REQUIREMENTS. 3. NO SMOKE DETECTOR REQ'D FOR THIS UNIT. NOTE: STRUCTURAL ENGRG. DONE BY OTHERS JUL PERMF' A B C D E F G H J PERMIT SET K 1 2 3 4 5 6 7 8 9 EIVED TUKWILA 2 5 2014 CENT9i0 MECHANICAL DESIGNERS, LLC P.O. BOX 5897 KENT, WA 98064 DIRECT (253) 951-1502 ALT# (253) 236-4391 jim@evanscromwell.com 5 STAR MECHANICAL CONTRACTORS 109 WASHINGTON BLVD. STE B. ALGONA, WA 98001 (253) 852-8284 COWNCOKA 10 SEAL LEGEND AND NOTES SHEET TITLE: CHECKED: JE a. DATE: 07/07/14 PROJECT NO. EC-14-5STAR-006 218-548-14 MO.O 0" 1" 2" SHEET SIZE IS TRUE SCALE WHEN ABOVE LINE MEASURES AS NOTED A H K EVAN-CROMWELL. A B C 4"X4" WOOD "SLEEPERS" FOR NATURAL GAS PIPE SUPPORT (E) 1/2" GAS PIPE (NATURAL GAS) PARTIAL ROOF PLAN SCALE: NONE C I D E (E) ROOF F MECHANICAL LEGEND - AS APPLICABLE PER DWGS. SYMBOL DESCRIPTION ABBREV. DESCRIPTION ABBREV. DESCRIPTION c CONDENSATE LINE (C) AHJ ABBREV APPROX ARCH BTU BTUH BLDG CAP CKT COP COMP CONN CONT CFM DEF, F DIA DN DWG DB EA ECON ELEC ELEV EAT EWB EDB EXIST, (E) ESP FLA HP AUTHORITY HAVING JURISDICTION ABBREVIATION APPROXIMATELY ARCHITECTURAL BRITISH THERMAL UNIT BRITISH THERMAL UNIT/HOUR BUILDING CAPACITY CIRCUIT COEFFICIENT OF PERFORMANCE COMPRESSOR CONNECTION CONTINUE, CONTINUATION CUBIC FEET PER MINUTE DEGREE FAHRENHEIT DIAMETER DOWN DRAWING DRY BULB EACH ECONOMIZER ELECTRICAL, ELECTRIC ELEVATION ENTERING AIR TEMPERATURE ENTERING WET BULB ENTERING DRY BULB EXISTING EXTERNAL STATIC PRESSURE FULL LOAD AMPS HORSE POWER KW LAT LDB LINT LWB MAX MFR MBH MCA MECH MIN MOCP NTS OSA PH PD POC RLA REF REQ'D RA RPM RM SA TEMP TYP V W/ KILOWATT LEAVING AIR TEMPERATURE LEAVING DRY BULB LEAVING WATER TEMPERATURE LEAVING WET BULB MAXIMUM MANUFACTURER THOUSAND BTUH MINIMUM CIRCUIT AMPS MECHANICAL MINIMUM MAXIMUM OVER CURRENT PROTECTION NOT TO SCALE OUTSIDE AIR PHASE PRESSURE DROP POINT OF CONNECTION RATED LOAD AMPS REFERENCE REQUIRED RETURN AIR REVOLUTIONS PER MINUTE ROOM SUPPLY AIR TEMPERATURE TYPICAL VOLTS, VOLTAGE, VENT WITH FLEXIBLE CONNECTION II ME DUCT SECTION (SUPPLY) DUCT SECTION (EXHAUST OR RETURN) Q THERMOSTAT DETAIL IDENTIFICATION NUMBER M1.0 N...,__,__----- — M0.1 SHEET ON WHICH DETAIL IS SHOWN SHEET WHERE DETAIL CALLOUT IS LOCATED — SECTION IDENTIFICATION LETTER SHEET ON WHICH SECTION IS SHOWN A M3.1 CONSTRUCTION NOTES: O REMOVE (E) RTU & INSTALL NEW TRANE RTU AS REQUIRED. INSTALL ADAPTER CURB AS REQUIRED IN SAME LOCATION. RE- CONNECET SUPPLY & RETURN DUCT (DOWN FLOW S&R UNIT. O2 RE -CONNECT 1/2" DIA. NATURAL GAS PIPE TO NEW RTU-1 PER 2012 ICC IFGC, INTERNATIONAL FUEL & GAS CODE(S) G REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 5 2014 City of Tukwila BUILDING DIVISION H J 2 3 4 5 6 7 8 MM - o S39 RECEIVED CITY OF TUKWILA JUL 2' 5 2014 PERMIT CENTER 10 PERMIT SET r- MECHANICAL DESIGNERS, LLC P.O. BOX 5897 KENT, WA 98064 DIRECT (253) 951-1502 ALT# (253) 236-4391 jim@evanscromweli.com 5 STAR MECHANICAL CONTRACTORS 109 WASHINGTON BLVD. STE B. ALGONA, WA 98001 (253) 852-8284 CROWN CORK AND SEAL PARTIAL ROOF PLAN SHEET TITLE: CHECKED: JE a ct 0 DATE: 07/07/14 PROJECT NO. EC-14-5STAR-006 218-548-14 0 0 MI.O 0' 1" 2" SHEET SIZE IS TRUE SCALE WHEN ABOVE LINE MEASURES AS NOTED