Loading...
HomeMy WebLinkAboutPermit M14-0155 - KIDDER MATHEWS - DUCTLESS SPLIT HEAT PUMPKIDDER MATHEWS 12886 INTERURBAN AVE S M14-0155 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2716000010 12886 INTERURBAN AVE S Project Name: KIDDER MATHEWS Permit Number: M14-0155 Issue Date: 8/8/2014 Permit Expires On: 2/4/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: EPROPERTY TAX INC DEPT #207 PO BOX 4900 , SCOTTSDALE, WA, 85261 MARK SMELTZLER 1012 CENTRAL AVE S , KENT, WA, 98032 PERFORMANCE HEATING/AC 1012 CENTRAL AVE S , KENT, WA, 98032 PERFOHA150RT Phone: (425) 251-0356 Phone: (425) 251-0356 Expiration Date: DESCRIPTION OF WORK: INSTALLATION OF (1) 1.5 TON DUCTLESS SPLIT 18 SEER HEAT PUMP FOR SERVER ROOM Valuation of Work: $6,811.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $285.10 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: Permit Center Authorized Signature: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Date: d04,00Y I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to thQconditions attached to this permit. Signature: Print Name: G/L- /Z5MC,.h Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Readily accessible access to roof mounted equipment is required. 2: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 3: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 4: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: ***MECHANICAL PERMIT CONDITIONS*** 8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 9: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA! Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: lu- O(s-s-- (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: Tenant Name: 12886 Interurban Ave S Kidder Mathews King Co Assessor's Tax No.: 271600-00 Suite Number: New Tenant: ❑ Yes ®..No PROPERTY OWNER Name: Rreef/CBRE Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: Mark Smeltzer Address: 1012 Central Ave S City: Kent State: WA Zip: 98032 Phone: (425) 251-0356 Fax: (253) 867-5775 Email: mark@pmghvac.com Floor: 1 MECHANICAL CONTRACTOR INFORMATION Company Name: Performance Mechanical Group Address: 1012 Central Ave S City: Kent State: WA Zip: 98032 Phone: (425) 251-0356 Fax: (253) 867-5775 Contr Reg No.: PERFOHA15ORT Exp Date: 04/30/2015 Tukwila Business License No.: BUS-0992987 Valuation of project (contractor's bid price): $ 6,811 Describe the scope of work in detail: Installation of (1) 1.5-ton ductless split 18 SEER heat pump for server room. Use: Residential: New ❑ Replacement ❑ Commercial: New 0 Replacement ❑ Fuel Type: Electric WI Gas ❑ Other: H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace > 100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system 1 Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfin Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat 1 Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AJJJ.HORIZED AGENT: Signature: Print Name: Mark Smeltzer Mailing Address: 1012 Central Ave S. Date: e ( ( Day Telephone: (425) 251-0356 Kent WA 98932 City State Zip 11: Applications Forms -Applications On Line 2011 Applications Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 DESCRIPTIONS PermitTRAK Cash Register Receipt City of Tukwila ACCOUNT QUANTITY PAID 30.2 M14-0155 Address: 12886:INTERURBAN AVE S. pn. 271600001a 302' MECHANICAL $219.30 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $186.80 TECHNOLOGY FEE $10.97 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2814 R000.322.900.04.00 0.00 $10.97 $230.27 Date Paid: Friday, August 08, 2014 Paid By: PERF MECH GROUP Pay Method: CREDIT CARD 772030 Printed: Friday, August 08, 2014 9:38 AM 1 of 1 CRWSYSTEMS r4-tf- iccci,- Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID $54.83 $54.83 $54.83 $54.83 PermitTRAK M 14-0155 Address: 12886 INTERURBAN AVE S Apn 2716000010 MECHANICAL PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R2758 R000.322.102.00.00 0.00 Date Paid: Friday, August 01, 2014 Paid By: DON LO PERF MECH GROUP Pay Method: CREDIT CARD 349553 Printed: Friday, August 01, 2014 9:58 AM 1 of 1 CRWSYSTEMS t INSPECTION NO. INSPECTION RECORD Retain a copy with permit M14 -Ogs5 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 Pro ect: ) Km A e 5 Type of Inspection: MP(, 1 ,, Al Address: / i k ' u't M j Date Called: ((j G.-4 Special Instructions: ` _�tJF__. r �e ')% S e %J �f r Date Wanted: - %L� a.mh p.m. Requester: Phone No:/ — V 5-1,0 Approved per applicable codes. t�J Corrections required prior to approval. COMMENTS: Inspector: 6\. hj} �y{j� /cc\ REINSPECTION FEE REQUIREO.rPriorto next inspection, fee must be paid at 6300 Southcenter Blvd` Suite 100. Call to schedule reinspection. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0155 PROJECT NAME: KIDDER MATHEWS DATE: 08/01/14 SITE ADDRESS: 12886 INTERURBAN AVE S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: ,-c Building Division Public Works 1 Fire Prevention Structural n Planning Division Permit Coordinator 11111 PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 08/05/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09/02/14 Approved Corrections Required n Approved with Conditions N Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERFORMANCE HEATING & A/' INC Page 1 of 2 Washington State Department of Labor & Industries PERFORMANCE HEATING & A/C INC Owner or tradesperson MILLER, DANIEL E Principals MILLER, DANIEL E, PRESIDENT ERDAHL, DARRIN, VICE PRESIDENT GOWIN, RICHARD L, VICE PRESIDENT (End: 04/26/2011) GOWIN, CONSTANCE F, VICE PRESIDENT (End: 11/15/2007) Doing business as PERFORMANCE HEATING & A/C INC WA UBI No. 600 601 386 1012 Central Ave S KENT, WA98032 425-251-0356 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. PERFOHA15ORT Effective — expiration 12/30/1985— 04/30/2015 Bond DEVELOPERS SURETY & INDEM CO Bond account no. 748802C Received by L&I 11/27/2007 Insurance American Fire & Casualty Co Policy no. BKA56064545 $12,000.00 Effective date 10/01/2007 Expiration date Until Canceled $1, 000, 000.00 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600601386&LIC=PERFOHA150RT&SAW= 08/08/2014 NEW 8X8'DOGHOUSE"FOR REFRIGERA770NPIPING, ROOFED IN. NEW CU-1 CONDENSER ON4XSLEEPERS, MIN. 10FTFROM ROOF EDGE SECURE SLEEPERS TOS7RUC7UREBELOW. EXISTING HVAC ROOFTOP UNIT (NO CHANGE) EXISTING SKYLIGHT —\ ENLARGE ROOF PLAN 1/4"=1=0" x x x SERVER ROOM SEE ENLARGE PLANS a A7DDERMA7NEWSSLOE x EXIS77NGSKY (NO CHANGE) \\- EXISI7NGROOFTOP HVACEQUIPMENT/) (NO CHANGE) BUILDING OUTLINE / PARTIAL ROOF PLAN MOUNTFC-1 TO NORTH WALL AT7FTA.F.F. & PER MANUFACTURERSINSTRUCTIONS. VERIFY LOCA770N AND HEIGHT WITH TENANT. REFRIGERANT AND PUMP CONDESATE PIPING UP THROUGH "DOGHOUSE" 1/4" LIQUID, 1/2" GAS CONNECT TO CU-I ON ROOF SEE ENLARREROOFPLAN 1/32" =1=0" SERVER F Civ I � E OFF- E ENLARGE SERVER ROOM PLAN 1/4"=1-O" ti EEPA RATE PERMIT REQUIED FOR: ❑ Mechanical GioElectrical althumbing alas Piping City of Tukwila BUILDING DIVISION REVISIONS No chan.- ; shall be made to the scope a{ , without prior approval of Gila Building Division. NOT is will require a new plan submittal -tide additional plan review fees. FILE COPY Permit No.4 jJas. Plan � roview approval is subject to errors and omission Approval of construe on documents doese . not the violation of any ad:pted code or ordinance. Receipt of approved Field Copy d conditions is acknowledged: By: Date: City of Tukwila BUILDING DIVISION PARCEL Na; 271600-0010 LEGAL DESCRIPTION.• GATEWAY CORPORATE CENTER LOT LESSPOR770N TO CITYOFTUKWILA FOR SIDEWALK WITHIN 77/EFOLG- POR OF STEPHEN FOSTER DONATION CLAIM NO38 & OF C C LEWIS DONATION CLAN NO 37IN NE 1/4 OF SEC770N 15-23-04- BEGIN ATA PT WHICH BEARSN40-01-05W920,15FTFROM MONUMENT ATA PT OF INTERSECTION OF CURVE ON C/L OF DUWAMISH-RENTON JUNC770N ROAD SAID PT OFINTERSECTION BEING APPROX 1000 FT E & 20 FT S OF QUARTER CORNER BE7WEENSEC770N14& 15 THN 4924-00 W835fTONA LINEPLT& 150FT NELYOFC,/L OF SAID DUWAMISH- RENTONJUNC770NROAD TOA POINTBEARING N 81-44-55 E 199.17 FT FROM POINT OF CURVE ON C,/L OF DUWAMISH RENTON JUNCTION ROAD SAID POINT BEING APPROX 1200 FTN& 440FT W OF QUARTER CORNER BETWEEN SEC77ONS 14 & 15771S4036--00 W20FT TO NELY MARGIN OF R/W OFPUGETSOUND ELECTRIC RAILWAY THN4924-00 W 980.29 fT THN 40-36-00E26.50fT TOPOB THS49-24-OOE16FT THN4036-00E60.50fT TH N20-27-49E31.95FT THN40 36-00E575.IOFT THN49 24-00 W5FT THS 40-36-00 W 66560FT TOPOB SCOPEOFWORK: INSTALLATIONOF(1)1.5-TON18SEER SPLIT A/C SYSTEM FOR SERVER ROOM. CODENOTES: 1) INSULATE REFRIGERANTPIPINGPER W.SEC. TABLEC403.28. 2) A 110V CONVENIENCE OUTLET SHALL BEWITHIN25'-0"OFOUTDOOR EQUIPMENT PER LM..C. SECTION306. 3) ROOF ACCESS TO EQUIPMENT TO COMPLY WITH LM..C. SECTION306. 4) THERMOSTAT TO COMPLY W/SECTION C403.2.4OFW.S..EC, DUCTLESS SPLIT SYSTEM AIR CONDITIONER SCHEDULE TAG DESCRIPTION PANASONIC MODEL TONS INDOOR FAN COOLING BTUH SEER REFR/G. PIPE ELECTRICAL SOUND dB(A) WEIGHT (LBS.) CFM ESP FLALIQUID GAS VOLTS PH MCA MOCP CU-1 CONDENSING UNIT CU-E18NKUA 1.5 N/A N/A N/A 17,100 18.0 1/4" 1/2 208/230 10 15.7 20 49 132 FC-1 FAN COIL CS-E18NKUA SEE CU-1 650 N/A 5.95 SEE CU-1 SEE CU-1 1/4" 1/2" * * 7.4 15 N/A 26 NOTES: • SYSTEMCU-1/FC-1 TOBEEXEMPTFROM ECONOMIZER REQUIREMENTS PER W.S.EC. SECTION C403.4.1, EXCEPTION #5, OPTION5A. • SYSTEMCU-1/AH-1 AHRI CERTIFICA770NNUMBER - 5292704 • PROVIDE ALL FACTORY ACCESSORIES TO ACCOMODATE LOW AMBIENT OPER4170N PARCEL#2716000010 *POWERED BY CIRCUIT FROM CU-1 SEE INSTALL MANUAL. MP1OiSs PROPERTY LINE RECEIVED Pv oAA1TY OF TUKWILA Z AUG .012014 PERMIT CENTER co Z O o) w SERVER ROOM HVAC nterurban Ave S CO COCO r DATE: 7/31/14 DRAWN: DL ENGR: MS APPVD: MS JOB NUMBER: 1276-14 M-1 SHEET 1 OF 1