Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M14-0161 - FOSTER HIGH SCHOOL - WALK-IN COOLER
FOSTER HIGH SCHOOL 4242 S 144T ST M14-0161 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov MECHANICAL PERMIT Parcel No: 1523049108 Permit Number: M14-0161 Address: 4242 S 144TH ST Issue Date: 8/27/2014 Permit Expires On: 2/23/2015 Project Name: FOSTER HIGH SCHOOL Owner: Name: TUKWILA SCHOOL DISTRICT Address: 4640 S 144TH ST, TUKWILA, WA, 98168 Contact Person: Name: CHARLIE HARRINGTON Address: 20838 SE 240 ST, MAPLE VALLEY, WA, 98038 Phone: (206) 870-8367 Contractor: Name: SEATEMP LLC Phone: (206) 870-8367 Address: 20838 SE 240TH ST, MAPLE VALLEY, WA, 98038 License No: SEATEL*8920W Expiration Date: Lender: Name: Address: DESCRIPTION OF WORK: INSTALLATION OF WALK IN COOLER Valuation of Work: $7,660.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $298.16 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: TUKWILA SEWER SERVICE,VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2012 2012 Permit Center Authorized Signature: Date: g -,)- k L( I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: F p I's,1`>\\NCr Date: 410111") This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 2: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 3: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 4: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 5: ***MECHANICAL PERMIT CONDITIONS*** 6: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 7: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4)(EXTEND SPRINKLER PROTECTION TO THE WALK-IN FREEZER.) 10: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 9: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 13: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 14: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 15: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0 1800 MECHANICAL FINAL 0 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 SouthcenterBlvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. tGE--citet Date Application Accepted: V {" l 14 Date Application Expires: O2 Nit S (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: King Co Assessor's Tax No.: 4242 South 144rth Street, Tukwila Tenant Name: Tukwila SD -Foster High School PROPERTY OWNER Name: Tukwila School District Address: 4640 144rth Street City: Tukwila State: Wa Zip: CONTACT PERSON — person receiving all project communication Name: Charlie Harrington Address: 20838 Se 240th Street City: Maple Valley State: WA Zip: 98038 Phone: (206) 870-8367 Fax: (425) 432-5048 Email: seatempl@yahoo.com Suite Number: Floor: New Tenant: ❑ Yes ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Sea -Temp, LLC Address: 20838 SE 240th street City: Maple Valley State: WA Zip: 98038 Phone: (206) 870-8367 Fax: (425) 432-5048 Contr Reg No.: ccseatel*892ow Exp Date: 09/16/2015 Tukwila Business License No.: 0114 I (1L Valuation of project (contractor's bid price): $ 7,660 Describe the scope of work in detail: Installation of a walk in freezer, Use: Residential: New ❑ Replacement ❑ Commercial: New 0 Replacement ❑ Fuel Type: Electric E Gas Other: H:WpplicationsTorms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty, Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 1 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BYL WS OFF STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWAGENT: Signature: Date: Print Name: Z-harlie Harrington Day Telephone: (206) 870-8367 Mailing Address: 20838 se 240th street H:Wpplications\Forms-Applications On Line \2011 Applications\alechanical Permit Application Revised 8-9-I I.docx Revised: August 2011 bh Maple Valley WA 98038 City State Zip Page 2 of 2 DESCRIPTIONS PermitTRAK Cash Register Receipt City of Tukwila ACCOUNT QUANTITY ( PAID 661.64__? M14-0160 Address: 4628 S 144TH ST Apn: 1523049164 363.48 MECHANICAL $349.50 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $247.10 PLAN CHECK FEE R000.322.102.00.00 0.00 $69.90 TECHNOLOGY FEE $13.98 TECHNOLOGY FEE R000.322.900.04.00 0.00 $13.98 M14-0161 Address: 4242 S 144TH n: 1523049108` 2981 MECHANICAL $286.69 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $196.85 PLAN CHECK FEE R000.322.102.00.00 0.00 $57.34 TECHNOLOGY FEE $11.47 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2809 R000.322.900.04.00 0.00 $11.47 $661.64 Date Paid: Thursday, August 07, 2014 Paid By: CHARLES E HARRINGTON Pay Method: CREDIT CARD H09091 Printed: Thursday, August 07, 2014 12:28 PM 1 of 1 CRWSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: , �'!f / / / tj L Type of Inspection:/ .,/ ._47 /—i/� Address: 2 4"2 / q1 icy s�`- Date Called: Spel Instructions: Date Wanted: a.m. p.m. Requester: xey✓ y Phone No: -10 a‘s-- 7ci/ Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Inspector: 6"1-- /70-4../x/i42_, Date: i' Aie REINSPECTION FEE REQUIRED. Prior to next inspection,fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit May—o/6/ PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188. (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proj c : R Type of Inspection: Addressa. Date Called: )//c Special Instructions: vim lk A, L ioi /At i:hdae9ne Date Wanted: ive a.m. Requester: o: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: r/ 147 /' ri(`A7 Inspector: Date: % > /k/,1 f REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit IN ECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 44111-o(6 ( Project: , Toste.4r-- f-(-(qk_ Sc6c. ( Type of, pi so ce tion: 1 lef.i,-,... Date Called: Special Instructions: (M Date d: Wanted: f, - a.m. p.m. "Reouesirr: '1)13nte,t: LJApproved per applicable codes. COMMENTS: Fc tozr.i.._ 6 r" rf ticQ Apt orrections required prior to approval. P(4. Iiik<-5/ jcf— hfel fQd o Igto Peer /Obi- a co 4,, (S7C , ru fr‘-itoe_c_3-( ey„, inspector: atr.....c Date:6 -8- REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection PC: (\KJ S 1 INSPECTION RECORD Retain a copy with permit MIS -01 1p INSPECTION NO. PERMIT NO.....A4 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd„ #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: f--- r . 4 1 Type ofilpsoection: r-- • . , A, L..., Addres: 4-7A 2 144 -S.1-, Date Called: Special Instructions:, (A0=0A , . _, Ne e Qs _Sp/ ^ 1(--1 e-/ 3-r- f:,e Date Wanted: — , -- -- , Requester: Phope No:f „,......„---)6 _ -'W s,3 Lo r7 LIApproved per applicable codes. Corrections required prior to approval. COMMENTS: (i)o(ef Aiku_sC R4 tt /1462_7—(EL S LAC Inspector r Date: 5- )5 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Cati to schedule reinspection. INSPECTION NO, INSPECTION RECORD Retain a copy with permit Mi 1-(vr6,1 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: U1Pr �} ICI(1 +�oJ Type of Inspection: _ �c.1 , f IOki —, it i 2 Address: 1i&26 E (-`-( '-i" Date Called: Special Instructions:. Date Wanted: ' ei —C l --- `—i Ca' p.m. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: —_'1dF?r r- i2+{ ! er="5( ;. Q•-r r Inspector: �1�tM4 t Y�L n • , Date:, ! REIN1SPECTION FEE REQUIRED. Prior to n1ext inspection, fee/must be jaid at 6300 Southcenter Btvd., Suite 100. Catt to schedule reinspection. City of Tukwila Department of Community Development 11/2/2015 CHARLIE HARRINGTON 20838 SE 240 ST MAPLE VALLEY, WA 98038 RE: Permit No. M14-0161 FOSTER HIGH SCHOOL 4242 S 144 ST Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 12/5/2015. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 12/5/2015, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M14-0161 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development 6/1/2015 CHARLIE HARRINGTON 20838 SE 240 ST MAPLE VALLEY, WA 98038 RE: Permit No. M14-0161 FOSTER HIGH SCHOOL 4242 S 144 ST Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 7/14/2015. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 7/14/2015, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M14-0161 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development 1/5/2015 CHARLIE HARRINGTON 20838 SE 240 ST MAPLE VALLEY, WA 98038 RE: Permit No. M14-0161 FOSTER HIGH SCHOOL 4242 S 144 ST Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 2/23/2015. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 2/23/2015, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, r Marshall Technician Fileo: M14-0161 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 'ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0161 PROJECT NAME: FOSTER HIGH SCHOOL SITE ADDRESS: 4242 S 144 ST DATE: 08/07/2014 X Original Plan Submittal Response to Correction Letter # Revision #_ Revision # before Permit Issued after Permit Issued DEPARTMENTS: Building Division la Public Works Fire Prevention Structural Awl C, Ot iti ■ Planning Division Permit Coordinator El PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 08/12/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required n (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 09/09/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping 0 PW ❑ Staff Initials: 12/18/2013 SEATEMP LLC Page 1 of 2 i Washington State Department of Labor & Industries SEATEMP LLC Owner or tradesperson HARRINGTON, CHARLES E Principals HARRINGTON, CHARLES E, PARTNER/MEMBER Doing business as SEATEMP LLC WA UBI No. 603 121 226 20838 SE 240TH ST MAPLE VALLEY, WA98038 206-870-8367 KING County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. SEATEL*8920W Effective — expiration 09/16/2011— 09/16/2015 Bond Lexon Ins Co Bond account no. 9804581 Received by L&I 01/09/2012 Bond history Insurance American Family Mutual Insuran Policy no. 46X2711701 Received by L&I 06/13/2014 Active. Meets current requirements. $12,000.00 Effective date 12/16/2011 Expiration date Until Canceled $4,000,000.00 Effective date 06/13/2014 Expiration date 06/13/2015 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603121226&LIC=SEATEL*8920W&SAW= 08/27/2014 Tukwila School District 406: Showalter Middle - Google Maps https://www.google.com/maps/previev Tukwila School District 406: Showalter (206) 901-7800 Imagery ©2014 Goo RECEIVED CITY OF TUKWILA AUG 0 7 2014 PERMIT CENTER to 2 le 4 1 of 1 7/30/2014 4:31 Ply A Brand of Heatcraft Refrigeration Products 2175 West Park Place Boulevard Stone Mountain, GA 30087 800.537.7775 www.larkinproducts.com LHT025L6B Hermetic Air-cooled Project: QUOTATION: AA20140731064317;0 Item No: 1 Location: , Submitted by: MIKE FRY Customer: DATE: 7/31/2014 Identity #: Tag: ® For Record By: ❑ For Approval Date: PHYSICAL & ELECTRICAL DATA REFRIGERANT COMPRESSOR CONNECTIONS (inches) RECEIVER CAPACITY (90%) NET WEIGHT SOUND DATA ALTITUDE AMBIENT TEMP Model No. HP Liquid Suction R404A/R507 CF09K6E 2 3/8 7/8 9 210 76 0 ft. CAPACIT Y (BTUH) at 95°F Ambient POWER SUPPLY COMPRESSOR FAN MOTOR MCAt MOP# Evap. Fan Defrost Heater Volts / Ph / Hz RLA LRA QTY HP FLA Air Elec. Air Elec. Amps Amps 208-230/1/60 15 87 2 1/15 1 20 29 30 40 6 23 tMCA=Minimum Circuit Ampacity #MOP = Maximum Overcurrent Protection DIMENSIONS (inches) A B C D E F G H J 28 1/4 37 3/ 4 17 1/ 4 1 3/ 4 2 9/16 4 9/16 2 3/ 8 21 1/ 8 38 1/ 4 DIMENSIONS (inches) K L M N P R S 4 1/16 1 7/ 8 3 2 3/ 4 115/8 Page 1 of 12 LARKIN A Brand of Heatcraft Refrigeration Products 2175 West Park Place Boulevard Stone Mountain, GA 30087 800.537.7775 www.larkinproducts.com LHT025L6B Hermetic Air-cooled Project: QUOTATION: AA20140731064317;0 Item No: 1 Location: , Submitted by: MIKE FRY Customer: DATE: 7/31/2014 Identity #: Tag: IZI For Record 0 For Approval By: Date: CAPACITY (BTUH) 40 °F SST 35°F SST 30 °F SST 25 °F SST 20 °F SST 15 °F SST 10°F SST 0 0 0 0 0 0 0 CAPACITY (BTUH) 5 °F SST 0 °F SST -5 °F SST -10 °F SST -15 °F SST -20 °F SST -25 °F SST 0 15400 13700 12000 10150 8300 6950 CAPACITY (BTUH) -30 °F SST -35 °F SST -40 °F SST 5750 0 0 SST = Saturated Suction Temperature STANDARD FEATURES Cabinet & Construction • Painted steel cabinets • Heavy duty steel raised base with 1-1/2" legs • Suction service valves for hermetic and scroll compressors located outside the cabinet • Semi -hermetic compressor models have a suction valve on the compressor and an access fitting on the suction line entering the cabinet • Receiver with fusible plug, liquid shutoff valve and charging port • Large electrical panel • Prefabricated wiring harnesses • Piping is pre -bent to eliminate leaks Coil: • Microchannel coil technology (not including 1-1/2 through 3 HP semi -hermetic models but including 29M2 models) • Completely leak tested in a helium environment • Liquid Drier/Sight Glass on 005-025/027-060 L6, ZF Scroll Compressor • Hermetic, semi -hermetic and scroll. R-22 and R-404A/507 available for both medium and low temperature applications • Spring -mounted compressors with vibration eliminators on all 1- 1/2 to 6 HP semi -hermetic compressors; 1/2 to 1 HP compressors are rigid mounted and have a discharge loop • Discharge service valves • Bump tested and allowed to cycle off on the high and low pressure control • Encapsulated, auto -reset, high and low pressure controls (adjustable low pressure control on low temperature models) Fan Motors: • Rated for 50 and 60 cycle application • Standard PSC or optional Variable Speed EC (VSEC) with 0rbus"' Controller • Fan guards and wiring conduit on indoor models • Specifically matched fans with motor and coil OPTIONS Page2of12 A Brand of Heatcraft Refrigeration Products 2175 West Park Place Boulevard Stone Mountain, GA 30087 800.537.7775 www.Iarkinproducts.com LCE694BB Low Profile Walk -In Project: AA20140731064317;0 Item No: QUOTATION: 2 Location: , Submitted by: MIKE FRY Customer: DATE: 7/31/2014 Identity #: Tag: ® For Record D For Approval PHYSICAL & ELECTRICAL DATA By: Date: DEFROST TYPE AIR FLOW VOLTAGE CAPACITY RATING TD RATING SST Approx. NET WEIGHT ALTITUDE Electric 1300 208 230/1/60 9400 10 -20 48 0 ft. FANS HEATERS CONNECTIONS (inches) QTY FLA MOTOR TYPE BLADE AMPS WATTS INLET OUTLET DRAIN 2 1 PSC 12.0 7.8 1800 1/2 5/8 3/4 DIMENSIONS (inches) A 8 C DEF G H J K L M 45.50 12.00 14.94 2.88 4.19 1.75 12.38 1.06 3.00 22.75 18.00 13.44 DIMENSIONS (inches) Page 4 of 12 METAL CAM -ACTION PANEL FASTENERS yTy EXTERIOR EXTERIOR - COVE BASE FOAM -FILL 2' DIA.- ACCESS HOLE AFTER ANCHOR INSTALL EXISTING CONCRETE SUBFLOOR SLAB 4' x4' xW STEEL FLOOR PLATE WITH - HILTI %' DIAMETER KB-TZ SEISMIC ANCHOR (ESR-1917 & LARR-25701) @CORNERS, DOOR JAMBS & PERIMETER WALL MAXIMUM 46' CENTERS 4' URETHANE ROOF PANEL COOLER 4' URETHANE WALL PANEL 4' URETHANE NSF FLOOR PANEL 1 1 1 1 I 1& 1 1 1 1 1 1 1 1 HILTI KB-TZ SEISMIC EXPANSION ANCHOR W/MINIMUM 2' EMBEDMENT (INSTALL PER MFG, INSTRUCTIONS) SEISMIC ANCHOR DETAIL (@ WALL) 1-1/2' = 1' -0' METAL CAM -ACTION PANEL FASTENERS • EXTERIOR EXTERIOR COVE BASE FOAM -FILL 2' DIA. ACCESS HOLE AFTER ANCHOR INSTALL EXISTING CONCRETE SUBFLOOR SLAB \\\ 4' URETHANE ROOF PANEL COOLER 4' URETHANE WALL PANEL 4' URETHANE NSF FLOOR PANEL • n 4' x4' xW STEEL FLOOR PLATE WITH HILTI 3/' DIAMETER KB-TZ SEISMIC ANCHOR (ESR-1917 & LARR-25701) @CORNERS, DOOR JAMBS & PERIMETER WALL MAXIMUM 46' CENTERS HILTI KB-TZ SEISMIC EXPANSION ANCHOR W/MINIMUM 2' EMBEDMENT (INSTALL PER MFG. INSTRUCTIONS) SEISMIC A\CHEIR DETAIL (@ WALL) 1-1/2' = l' -0' / 8'-1 0 PLATFORM ADDITION NEW BOLLARD O� NEW 36" HIGH RAILING RAMP UP FREEZER EXISTING CONCRETE MOP SINK FOSTER FLAN 1/4" I'-0" SEPARATE PERMIT REQUIRED FOR: 0 Mechanical 0Etactical 0,Piumbing at Gas Piping City of Tukwila BUILD:N DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fens. E COpy REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 12014 City of BUILDIN rag COPY Permit No. P{g1111r1YsW *pool NW MANN* Appnowi d avilimisn datittiNe ��1: � ihosiollon of any ado* ode witt dope c MOM MOM ila VISION RECEIVED CITY OF TUUKWILA AUG 0 7 2014 PERMIT CENTER o Y U Mit-4-'4)1(er tt a o� =a v� ¢ 1 N mx RESTAURANT SPACE DESIGN, INC FURNISHINGS EQUIPMENT D 2 w V a z 0 DRAWING: FLOOR FLAN DATE: 7/15/14 SCALE: 1/4' = 1'-0' DRAWN: PDL JOB NO.: 502 SHEET NO.: J WALK-IN MATERIAL LIST 15' -10' VEY. 15' -7' OA BOX 1/2 • A FINISHED FLOOR! VFY. FRFEZfR RAMP -UP � T O > fo \\-EXISTING MOP SINK 7' -0' PLATFORM VFY. NEW 36' HIGH RAILING 8' -5' V NEV BOLLARD VFY. VFY. FLOOR PLAN 15' -7' OA BOX / / / / / / / VFY. STUB -OUT FCONDUIT (TYP.) f®1 PO 4' NSF FLOOR PANELS DOOR V/ 1/2' SLOPED S1 L 3' 1-BEAM STRUCTURAL STEEL PLATFORM VFY. > PLATFORM ADDITION B B= rGROUND LEVEL REMOVABLE GALVANIZED PANELS 7' -0' PLATFORM VFY. ELEVATION A -A CU NEW BOLLARD BY OTHERS FINISHED FLOOR GROUND LEVEL fo 3' 1-BEAM S RUCTURAL STEEL PLATFORM 7' -8' OA BG 8' 7' PLATFORM VFY. ELEVATION B-B 3 > REVIEWED FOR CODE COMPLIANCE APPROVED AUG 21 2014 > City of Tukwila BUILDING DIVISION PANEL- MATERIAL LIST INTERIOR WALL PANEL FACING 26G STUCCO EMBOSSED GALVANIZED INTERIOR CLG. PANEL FACING 26G STUCCO EMBOSSED GALVANIZED EXPOSED EXT. PANEL FACING 26G STUCCO EMBOSSED GALVANIZED UNEXPOSED EXT. PANEL FACING 26G STUCCO EMBOSSED GALVANIZED INSULATION 4' URETHANE, CLASS 1 - UL LISTED FREEZER: NSF FLMR PANFI SUBFLOOR MEMBRANE INSIDE FLOOR FACING INTERIOR BASE EXTERIOR BASE (EXPOSED) INTERIOR RAMP -UP H-20 SERIES FREEZER DOOR INTERIOR FACING EXTERIOR FACING INSULATION LATCH TOP HINGE BOTTOM HINGE CLOSER DOOR HEATER @FZR JAMB/SILL HEATER @FZR SILL PLATE @FZR WINDOW KICK PLATES ACCESSORIES DIGITAL THERMOMETER & LIGHT SWITCH ASSEMBLY LIGHT FIXTURE VACUUM VENT @FZR PLATFORM 6MIL VISQUEEN SHEET WITH JOINTS LAPPED .125' ATP W/ 3/4' PLYWOOD BACKING INTEGRAL 1/2' NSF RADUIS 6' HIGH STUCCO GALVANIZED COVED MOULDING 36' W x 24' D STANDARD DUTY WITH LOCKABLE (36' WIC x 78' HIC) 26G STUCCO EMBOSSED GALVANIZED 26G STUCCO EMBOSSED GALVANIZED 4' URETHANE, CLASS 1 - UL LISTED KASON 058 WITH 0481 INSIDE RELEASE HANDLE (2) KASON 01245 CAM -LIFT (U KASON 01248 CAM -LIFT SPRING LOADED DICTATOR 8V1600 SNUGGER 120V, 230W HEATER CIRCUIT WITH T-STAT 120V, 230W HEATER CIRCUIT WITH T-STAT STAINLESS STEEL, TYPE 304 02B 20' x 15' VIEWPORT WINDOW 36' HIGH ATP KICK PLATES INTER./EXTER. QTY WEISS INSTRUMENTS 024DT-SP-LT FLUSH LED DIGITAL 1 THERMOMETER & 15A LIGHT SWITCH W/PILOT LIGHT KASON 01806 VAPORPROOF COMPACT FLUORESCENT 2 FIXTURE W/GU-24 BASE & 26W LAMP, 120VAC KASON 01830 2-WAY HEATED VENT: 120V, 23W 1 7'-0' x 8'-7' x 23' HT4 GALVANIZED PANELS 1 GENERAL NOTES, 1. WIRING OF FIXTURES AND POWER CONNECTIONS BY JOBSITE ELECTRICIAN. 2. SILICONE, CAULKING AND PANEL SECTION FASTENER HEX KEY FURNISHED LOOSE. RECEIVED CITY OF TUKWILA AUG 0 7 2014 PERMIT CENTER REFRIGERATOR MANUFACTURERS LLC 17081 EDWARDS ROAD CERRITOS, CA 90703 TEL (562) 926-2006 amocx RESTAURANT SPACE DESIGN, INC. nun FREEZER - OPTION 3 614-10 n" 3 of 5 TBD AIRDYNE s* F'AS NOTED 06-12-14 .non m R'"''M THE LE 461 xxxxx