Loading...
HomeMy WebLinkAboutPermit M14-0165 - SHIEKH SHOES - ROOFTOP CONDENSOR, FAN COIL UNIT AND DUCTINGSHIEKH SHOES 1031 SOUTHCENTER MALL M14-0165 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 9202470010 1031 SOUTHCENTER MALL Project Name: SHIEKH SHOES Permit Number: M14-0165 Issue Date: 10/13/2014 Permit Expires On: 4/11/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, CA, 92013 BRUCE MARTENEY 1640 VIA PALOMARES , SAN DIMAS, CA, 91773 HINKLER CONSTRUCTION INC 1905 N WILLIAMS, MESA, AZ, 85203 HINKLCI915NG 1!/ Phone: (909) 599-7054 Phone: (480) 835-6886 Expiration Date: DESCRIPTION OF WORK: NEW ROOFTOP CONDENSOR, NEW FAN COIL UNIT, NEW DUCTING Valuation of Work: $30,000.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $585.58 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2014 2012 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and a ree to the cyf itions attached to this permit. Signature: Print Name: /&/4/I�4Je6 /19/4,Q ,4 Date: �O— /3 -o?o/V This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Readily accessible access to roof mounted equipment is required. 2: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 3: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 4: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: ***MECHANICAL PERMIT CONDITIONS*** 8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 9: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 18: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 12: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 16: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 20: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 21: All fire alarm components to be tied to the main mall fire alarm panel. 13: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 17: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 11: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 19: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov NIechanica Project Nts..;__ Date Application Accepted: Date Applicatorr:Exptres (For o, f,ce usezny) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 1031 SQ(s114 Tenant Name: .., +t j4 PROPERTY OWNER Name: , FI CLO Address: )14o) 1414...t gine Z t, n City:�0.5 ��v S State.44 Zip:1002s CONTACT PERSON — person receiving all project,; Name: J1AR,f Address: L64O v 14 'PAi.oI1ARC3 City:5 4 4 atr'1A5 Stater Zip:q,7 2 Phone: „50q -Z0s-zy Fax: Email: Poi le.ci @ vs- Li $aV1. King Co Assessor's Tax No.: Suite Number: 4 2.0 Floor: New Tenant: ❑ Yes ❑ ..No MECIIANICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ 30' 000 Describe the scope of work in detail: paspap-mp C.04-10 61J t iJEW r-AI.` COIL 04 Y?, 1461.1 DUC111-11 Use: Residential: Commercial: Fuel Type: Electric New ❑ Replacement ❑ New ❑ Replacement Gas Other: H:Wpplications\rorms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 efm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator - domestic Incinerator - comm/industrial Unit Type Qty Fire damper Diffuser M Thermostat l Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction - in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review - applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CFjRIFIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PIE JURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING V/NE OR AUTHORIZED AGENT: Signature: Date: 5 •t (' y'' �,, Print Name: "' C I TJ Day Telephone: 109 ' C c:19 7z CY Mailing Address: 1440 V LA PA1.a 4tR-€' , 5A1.1 D $ GA 9 I 7 7 3 City H:Wpplications\Forms-Applications On Line \2011 Applications'Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh State Zip Page 2 of 2 DESCRIPTIONS PermitTRA Cash Register Receipt City of Tukwila ACCOUNT QUANTITY PAID ;,1 4-0 ress: 1031 SOUTHCENTER. n.i920247001 • 1,859.4 DEVELOPMENT $1,771.10 PERMIT FEE R000.322.100.00.00 0.00 $1,766.60 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $88.33 TECHNOLOGY FEE R000.322.900.04.00 0.00 $88.33 44,07 ress 1SOUTHCENTER n:12024700 ELECTRICAL $802.80 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $802.80 TECHNOLOGY FEE $40.14 TECHNOLOGY FEE R000.322.900.04.00 0.00 $40.14 14-0165.. ; Address: 1031 SOUTHCENTER MALL Apn: 9202470010 72. MECHANICAL $450.45 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $417.95 TECHNOLOGY FEE $22.52 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R3274 R000.322.900.04.00 0.00 $22.52 $3,175.34 Date Paid: Thursday, October 09, 2014 Paid By: HINKLE CONSTRUCTION Pay Method: CREDIT CARD 05115G Printed: Thursday, October 09, 2014 3:18 PM 1 of 1 CRIVYSTEMS DESCRIPTIONS PermitTRAK . Cash Register Receipt City of Tukwila ACCOUNT QUANTITY PAID 1,461.60' D14-0271 Address: 1031 SOUTHCENTERMALL n: 9202470010 148. DEVELOPMENT $1,148.29 PLAN CHECK FEE R000.345.830.00.00 0.00 $1,148.29 EL14-0799 Address: 1031 SOUTHCENTER MALL n: 920247001 ELECTRICAL $200.70 PLAN CHECK FEE R000.345.832.00.00 0.00 $200.70 M14-0165 Address: 1031:SOUTHCENTER M pn: 920247001 12 MECHANICAL $112.61 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R2873 R000.322.102.00.00 0.00 $112.61 $1,461.60 Date Paid: Friday, August 15, 2014 Paid By: AMIR SHIEKH SHIEKH SHOES Pay Method: CREDIT CARD 00537G Printed: Friday, August 15, 2014 2:54 PM 1 of 1 CliWYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION GM 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: • Type of Inspection: Address: l,� r Sc AA%�-11 Date Called: .sNt v /� t�� P `/` �Lc Special Instructions: Date Wanted: j I - ,� r ,a.m., Requester: Phone No: Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: ( 0 j ; ( (4-) tilrAeir P tnsprtor: Date: REINSPECTION FEE REQUIRED, Prior to next inspection, fee must be paid at 6300 Southcenter Btvd., Suite 100. Gael to schedule reinspection. s A INSPECTION RECORD Retain a copy with permit INSPECTION NO, PERMIT NO. i$114-01105 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project:, -Type of Inspection: Address: S( ARM) Date Called: tee )4- r (ei /1- I ; ) \ Special Instructions: 1 Al)i//- ./1--- ' - Date Wanted: ) tD - )4 .t--*.'-'1.a m• Requester: Phone No: ..-- Approved per applicable codes. EJCorrections required prior to approval. COMMENTS: inspe or -bate: 1 I 7/0• 1 4— REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION" NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter"Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Pro)ert• s t! Typew' Address: t . ti � � � � { 1 Date Called: 5moge sti-i-r- ,/ Special instructions: Date Wanted: / t ... r' p.m. Requester: Phone No: �. Approved per applicable codes. Corrections required prior to approval. COMMENTS: S, 3 _. L) j C 4 _ — K.- 1_.1t ,7 3 A 3 "',05f .. ' J th+ A. -"" s er_.) c A"f� 1\3 (;' -1-0 I i', _.1 e c_ i (j. ri f1 (' I i REIINSPECTIONFEE R .r to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. �12 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 f f4 0,0 5 Project: SiA t 0(11\ S' 0e5 Type,of Inspection: Q i(OjAiot r-� Me(A Address:j� I, l .Si A-// Called: Date me `t - 7- Ai .A L _ .....- Special Instructions: Date Wanted: . Requester: Phone No: , 7 Approved per applicable codes. Corrections required prior to approval. COMMENTS: - A--Ico ,oe ocT rAsubEtroiti Albro sQI (L0JCn t tJ v. 1 \. tl Inspector: AA( -4tA REINSPECTION 1=EE lEQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: / ( / q _. ( 4 441 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Al 14-O((DS Project � _& , S c)'4� Type of Inspection; Me I\ LJCtM. ! A Address:. Date Called: I Special Instructions: Date Wanted: a.m. Requester: Phone No: Approved per applicable codes. t.._.JCorrections required prior to approval. COMMENTS: a,x .l p` r`-or .)n``r ,,t. i ).4 1 Date: Inspeftor: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION: RECORD Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:� , e,- k �ks T�p� of In�sp�ectio/ye - , J!$v Address: /031 S ,C„ Al pr�L Suite #: Contact Person: Special Instructions: Phone No.: JApproved per applicable codes. PCorrections required prior to approval. COMMENTS: CA- N ►4-1, c� — a% sf, , L L A>- . s A - Aare 4 s-ed 12 Needs Shift Inspection: r Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:/7 6t r _- Date: ///d jl/y Hrs.: 1 V ( $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0165 PROJECT NAME: SHIEKH SHOES DATE: 08/15/14 SITE ADDRESS: 1031 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: c Building Division Public Works 114 n Fire Prevention Structural Planning Division Permit Coordinator n PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 08/19/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 09/16/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 HINKLE CONSTRUCTION INC Page 1 of 2 Washington State Department of Labor & Industries HINKLE CONSTRUCTION INC Owner or tradesperson HINKLE, JACKIE E Principals HINKLE, JACKIE E, PRESIDENT HINKLE, FRANCES S, VICE PRESIDENT WA UBI No. 602 843 933 1905 N WILLIAMS MESA, AZ85203 480-835-6886 Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. HINKLCI915NG Effective — expiration 08/07/2009— 08/07/2015 Bond American Contractors Indem CO Bond account no. 100093672 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 08/05/2009 08/05/2009 Expiration date Until Canceled Insurance Mt Hawley Ins Co $1,000,000.00 Policy no. 2788339/001 Received by L&I Effective date 12/12/2013 11/19/2013 Expiration date 11/19/2014 Insurance history Savings https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602843933&LIC=HINKLCI915NG&SAW= 10/13/2014