Permit M14-0170 - ANDOVER EXECUTIVE PARK - ROOFTOP COOLING UNIT REPLACEMENT
ANDOVER EXECUTWE PARK 698 INDUSTRY DR EXPIRED 03/31/2015 M14-0170 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov 2523049008 698 INDUSTRY DR MECHANICAL PERMIT Project Name: ANDOVER EXECUTIVE PARK Permit Number: M14-0170 Issue Date: 9/29/2014 Permit Expires On: 3/28/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BLUE DOG PROPERTIES TRUST PO BOX 847 C/O THOMSON REUTERS PTS, CARLSBAD, WA, 92018 MARK SMELTZER 1012 CENTRAL AVE S , KENT, WA, 98032 PERFORMANCE HEATING/AC 1012 CENTRAL AVE S, KENT, WA, 98032 PERFOHA1SORT Phone: (425) 251-0356 Phone: (425) 251-0356 Expiration Date: DESCRIPTION OF WORK: REPLACE FAILING 4-TON ROOFTOP PACKAGE COOLING UNIT WITH LIKE FOR LIKE IN SAME LOCATION. CONNECT NEW UNIT TO EXISTING DUCTS, POWER SUPPLY, AND OTHER UTILITIES. Valuation of Work: $8,400.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $311.22 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2014 2012 Permit Center Authorized Signature: Uat. Date: —I )-"f"(� I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development it and agr a conditions attached to this permit. Signature: Print Name: ZS©\ to This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Readily accessible access to roof mounted equipment is required. 2: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 3: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 4: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: ***MECHANICAL PERMIT CONDITIONS*** 8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 9: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKw_ Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. y\(L- 6110 Date Application Accepted: Date Application Expires: (For office use only) aaliq MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 252304-9008 Site Address: 698 Industry Drive, Tukwila, WA 98188 Suite Number: Floor: 1 Tenant Name: Vacant -Ready for Lease PROPERTY OWNER Name: NCWP ANDOVER EXECUTIVE PARK Address: 630 INDUSTRY DR 98188 City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Mark Smeltzer Address: 1012 Central Ave S City: Kent State: WA Zip: 98032 Phone: (425) 251-0356 Fax: (253) 867-5775 Email: mark@pmghvac.com New Tenant: ❑ Yes ❑✓ ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Performance Mechanical Group Address: 1012 Central Ave S City: Kent State: WA Zip: 98032 Phone: (425) 251-0356 Fax: (253) 867-5775 Contr Reg No.: PERFOHA1SORT Exp Date: 04/30/2015 Tukwila Business License No.: BUS-0994165 Valuation of project (contractor's bid price): $ 8,400 Describe the scope of work in detail: Replace failing 4 ton Rooftop Package Cooling Unit with like -for -like unit in the same location. Connect new unit to existing ducts, power supply and other utilities. Use: Residential: New ❑ Replacement 0 Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas ❑ Other: H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-11 .docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfin 1 Unit Type Qty Air handling unit >10,000 cfin Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Therniostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OG�9��JT1�0 ZED AGENT: Signature: Date: Date: 08/25/2014 Print Name: Mark Smeltzer Day Telephone: (425)251-0356 Mailing Address: 1012 Central Ave S Kent WA 98032 City State Zip H:' ApplicationsForms-Application, On Line. 01 1 Applications.Mechanical Permit Application Revised 8-9-1 I .docx Revised: August 2011 bh Page 2 of 2 DESCRIPTIONS PermitTRAK Cash Register Receipt City of Tukwila ACCOUNT QUANTITY PAID 31122 M14-0170 Address: 698 INDUSTRY DR "' Apn: 2523049008 311.2 MECHANICAL $299.25 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $206.90 PLAN CHECK FEE R000.322.102.00.00 0.00 $59.85 TECHNOLOGY FEE $11.97 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2933 R000.322.900.04.00 0.00 $11.97 $311.22 Date Paid: Tuesday, August 26, 2014 Paid By: PERFORMANCE MECHANICAL GROUP Pay Method: CREDIT CARD 894313 Printed: Tuesday, August 26, 2014 10:02 AM 1 of 1 CRWSYSTEMS 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431-2451 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 lq-orio Project: ``� ' A vo c r 'r'"l e IZ-- Type -of Inspection: 1--' ! N.3 AL_ Address: (, ,C( ?) - --M t "/ Date Called: Special Instructions: r Date Wanted: 40_.__awlne m. Requester: nn Phone No: I —I 2 5 - 6 1 --03S Approved per applicable codes. tJ Corrections required prior to approval. COMMENTS: A 4 i )----• 1 E I-CC?"i r t c eY t P' .4r1, -8- 4:), j, I/-f'' �. i 2i,� •-I Lev �' r:� �i rPd Inspector: A c Date: tr)-- 1 1 / I ` REINSPECTION FEE REQUIRED. Prior to nixt inspection, fee must be paid/at 6300 Southcenter BlJd., Suite 100. CCatl to schedule reinspection. • General Data FILE COPY Table 1. General data - 3-4 tons - standard efficiency 3 Tons 4 Tons/ T/YSC036E1 T/YSC036E3,4,W T/YSC048E1 T/ SCO48 3,4,W Cooling Performance(a) Gross Cooling Capacity EER/SEER(b) Nominal cfm/AHRI Rated cfm AHRI Net Cooling Capacity System Power (kW) 35,620 11.5/13.0 1,200/1,200 35,000 3.04 37,150 11.2/13.0 1,200/1,200 35,800 3.20 49,210 11.1/13.0 1,600/1,600 48,000 4.32 AV 49,450 10.9/13.0 1,600/1,600 48,000 4.39 Compressor Number/Type 1/Scroll 1/Scroll 1/Scroll 1/Scroll Sound Outdoor Sound Rating (dB)(C) 81 81 82 / 82 ` Outdoor Coil - Type Configuration Tube Size (in.) Face Area (sq. ft.) Rows/FPI Lanced Full Face 0.3125 10.96 2/16 Lanced Full Face 0.3125 9.59 2/16 Lanced Full Face 0.3125 10.96 2/16 Lanced Full Face 0.3125 10.96 2/16 Indoor Coil - Type Configuration Tube Size (in.) Face Area (sq. ft.) Rows/FPI Refrigerant Control Drain Connection Number/Size (in.) Lanced Full Face 0.3125 7.71 3/16 Thermal Expansion Valve 13/4 NPT Lanced Full Face 0.3125 7.71 3/16 Thermal Expansion Valve 13/4 NPT Lanced Full Face 0.3125 7.71 4/16 Thermal Expansion Valve 13/4 NPT Lanced Full Face 0.3125 7.71 4/16 Thermal Expansion Valve 13/4 NPT Outdoor Fan - Type Number Used/Diameter (in.) Drive Type/No. Speeds cfm Motor hp Motor rpm Propeller 1/22 Direct/1 3,466 0.33 1,075 Propeller 1/22 Direct/1 3,375 0.33 1,075 Propeller 1/22 Direct/1 3,411 0.33 1,075 Propeller 1/22 Direct/1 3,403 0.33 1,075 Indoor Fan - Type (Standard) Number Used/Diameter (in.)/Width (in.) Drive Type/No. Speeds/RPM Number Motors Motor hp Motor Frame Size FC Centrifugal 1/11x11 Direct/5(d) 1 0.75 48 FC Centrifugal 1/11x11 Belt/Variable/1,750 1 1.0 56 FC Centrifugal 1/11x11 Direct/5(d) 1 1.0 48 FC Centrifugal 1/11x11 Belt/Variable/1,750 1 1.0 56 Filters(e) Type Furnished Number Size Recommended Throwaway (2) 20x30x2 Throwaway (2) 20x30x2 Throwaway (2) 20x30x2 Throwaway (2) 20x30x2 Refrigerant Charge(O Pounds of R-410A 6.3 6.0 7.0 7.0 continued on next page 28 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 2 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 2 6 2014 PERMIT CENTER somm- OPRUO 0 General Data Table 1. General data - 3-4 tons - standard efficiency (continued) 3 Tons 4 Tons T/YSC036E1 T/YSC036E3,4,W T/YSC048E1 T/YSC048E3,4,W Heating Performance(9) (Gas/Electric Only) Heating Input Low Heat Input (Btu) 60,000 60,000 60,000 60,000 Mid Heat Input (Btu) 80,000 80,000 80,000 80,000 High Heat Input (Btu) 120,000 120,000 120,000 120,000 Heating Output Low Heat Input (Btu) 48,000 48,000 49,000 48,000 Mid Heat Input (Btu) 65,000 64,000 65,000 64,000 High Heat Input (Btu) 96,000 96,000 96,000 96,000 AFUE%(h) Low Heat Input (Btu) 78 80 79 80 Mid Heat Input (Btu) 78 80 79 80 High Heat Input (Btu) 78 80 79 80 Steady State Efficiency% Low Heat Input (Btu) 80 80 81 80 Mid Heat Input (Btu) 81 80 81 80 High Heat Input (Btu) 80 80 80 80 No. Burners Low Heat Input (Btu) 2 2 2 2 Mid Heat Input (Btu) 2 2 2 2 High Heat Input (Btu) 3 3 3 3 No. Stages Low Heat Input (Btu) 1 1 1 1 Mid Heat Input (Btu) 1 1 1 1 High Heat Input (Btu) 1 1 1 1 Gas Supply Line Pressure Natural (minimum/maximum) 4.5/14.0 4.5/14.0 4.5/14.0 4.5/14.0 LP (minimum/maximum) 11.0/14.0 11.0/14.0 11.0/14.0 11.0/14.0 Gas Connection Pipe Size (in) Low Heat 1/2 1/2 1/2 1/2 Mid Heat 1/2 1/2 1/2 1/2 High Heat 1/2 1/2 1/2 1/2 (a) Cooling performance is rated at 95°F ambient, 80°F entering dry bulb, 67°F entering wet bulb. Gross capacity does not inc ude the effect of fan motor heat. AHRI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to f20% of nominal cfm. Units are certified in accordance with the Unitary Air -Conditioner Equipment certification program, which is based on AHRI Standard 210/240. (b) EER and/or SEER are rated at AHRI conditions and in accordance with DOE test procedures. (c) Outdoor Sound Rating shown is tested in accordance with AHRI Standard 270. For additional information refer to Table 137, p. 181. (d) For multispeed direct drive rpm TSC values, reference Table 33, p. 81. For multispeed direct drive rpm YSC (low & medium gas heat) values reference Table 34, p. 82. For multispeed direct drive rpm YSC (high gas heat) values reference Table 35, p. 83. (e) Optional 2" MERV 8 and MERV 13 filters also available. (f) Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. (g) Heating performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards. Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level. Applicable to Gas/Electric units only. (h)AFUE is rated in accordance with DOE test procedures. P s , M • 13T-PRCO23AG-EN M • 29 Mechanical Specifications - 3-10 Ton R-410A PKGD Unitary Cooling Rooftop Item: Al Qty: 1 General The units shall be convertible airflow. The operating range shall be between 115°F and 0°F in cooling as standard from the factory for units with microprocessor controls. Operating range for units with electromechanical controls shall be between 115°F and 40°F. Cooling performance shall be rated in accordance with ARI testing procedures. All units shall be factory assembled, internally wired, fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be cULus listed and labeled, classified in accordance for Central Cooling Air Conditioners. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather -resistant baked enamel finish. Units surface shall be tested 672 hours in a salt spray test in compliance with ASTM B117. Cabinet construction shall allow for all maintenance on one side of the unit. Service panels shall have lifting handles and be removed and reinstalled by removing two fasteners while providing a water and air tight seal. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil -faced, fire -retardant permanent, odorless glass fiber material. The base of the unit shall be insulated with 1/8", foil -faced, closed -cell insulation. All insulation edges shall be either captured or sealed. The units base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8" inch high downflow supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or, where seams exist, it shall be double -hemmed and gasket -sealed. The ribbed top adds extra strength and enhances water removal from unit top. Filters Throwaway filters shall be standard on all units. Optional 2-inch MERV 8 and MERV 13 filters shall also be available. Compressors All units shall have direct -drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Dual compressors are outstanding for humidity control, light Toad cooling conditions and system back-up applications. Dual compressors are available on 7%-10 ton models and allow for efficient cooling utilizing 3-stages of compressor operation for all high efficiency models. Notes: Crankcase heaters are optional on TSC (036, 048, 060, 072, 090, 102, 120); standard on THC (036, 048, 060, 072, 092, 102, 120). Evaporator and Condenser Coils Internally finned, 5/16" copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. The microchannel type condenser coil is standard for the TSC 10 ton models and 7% ton high efficiency models. The microchannel type condenser coil is not offered on the 7% ton dehumidification model. Due to flat streamlined tubes with small ports, and metallurgical tube-tofin bond, microchannel coil has better heat transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume, which leads to better compressor reliability. Compact all -aluminum microchannel coils also help to reduce the unit weight. All -aluminum construction improves re-cyclability. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin protection. In addition, flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 600 psig. The assembled unit shall be leak tested to 465 psig. The condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning. A removable, reversible, double -sloped condensate drain pan with through the base condensate drain is standard. Outdoor Fans The outdoor fan shall be direct -drive, statically and dynamically balanced, draw -through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. FLD = Fumished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 3 of 14 Installed by Others Indoor Fan The following units shall be equipped with a direct drive plenum fan design (T/YSC120E, T/YHC092, 102, 120E). Plenum fan design shall include a backward -curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. 3-5 ton units (standard efficiency 3-phase or high efficiency 3-phase with optional motor) are belt driven, FC centrifugal fans with adjustable motor sheaves. 3-5 ton units (1-phase or high efficiency 3-phase) have multispeed, direct drive motors. All 6-8% ton units (standard efficiency) shall have belt drive motors with an adjustable idler -arm assembly for quick -adjustment to fan belts and motor sheaves. All motors shall be thermally protected. All 10 tons and 71/2-8'/2 (high efficiency) have variable speed direct drive motors. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Controls Unit shall be completely factory -wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. A choice of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for volt control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized Microprocessor shall provide anti -short cycle timing and time delay between compressors to provide a higher level of machine protection. Refrigerant Circuits Each refrigerant circuit offer thermal expansion valve as standard. Service pressure ports, and refrigerant line filter driers are factory -installed as standard. An area shall be provided for replacement suction line driers. Phase monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase Toss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. There are no field adjustments. The module will automatically reset from a fault condition. Accessory - Economizer This accessory shall be available with or without barometric relief. The assembly includes fully modulating 0-100 percent motor and dampers, minimum position setting, preset linkage, wiring harness with plug, spring return actuator and fixed dry bulb control. The barometric relief shall provide a pressure operated damper that shall be gravity closing and shall prohibit entrance of outside air during the equipment off cycle. Optional solid state or differential enthalpy control shall be available for either factory or field installation. The economizer arrives in the shipping position and shall be moved to the operating position by the installing contractor. FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 4 of 14 Installed by Others Unit Dimensions - 3-10 Ton R-410A PKGD Unitary Cooling Rooftop Item: Al Qty: 1 EVAPORATOR SECTION ACCESS PANEL CONDENSATE DRAIN (ALT) 3/4"-14 NPT DIA. HOLE THROUGH THE BASE CONDENSATE Ifit ant SUPPLY 16" r 23 1/2" RETURN ONDENSER FAN ONDENSER COIL NIT CONTROL WIRE 7/8' DIA HOLE SERVICE GAUGE PORT ACCESS 1 3/8" DIA. HOLE NIT POWER WIRE ONTROL AND COMPRESSOR ACCESS PANEL 2" ELECTRICAL CONNECTION (SINGLE POINT POWER WHEN HEAT INSTALLED) 4 3/16" 24" i 15 1/2" PLAN VIEW UNIT 9 1/4" 14" DIMENSION DRAWING 1 RETURN SUPPLY 14 3/4" CONDENSATE 69 7/8" L3 5/8" 23 1/4' 4 3/4" 3 3/16" PACKAGED COOLING NOTES: 1. THRU -THE -BASE ELECTRICAL IS NOT STANDARD ON ALL UNITS. 2. VERIFY WEIGHT, CONNECTION, AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION 361 /4" 4 1/4" 5 9/16' 7 5/8" DIMENSION DRAWING 1> HORIZONTAL AIR FLOW FLD = Fumished by Trane U.S. Inc. dba Trane / Equipment Proposal Installed by Others Page 5 of 14 Unit Dimensions - 3-10 Ton R-410A PKGD Unitary Cooling Rooftop Item: Al Qty: 1 3/4"-14 NPT DRAIN CONNECTION ISOMETRIC -PACKAGED COOLING FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 6 of 14 Installed by Others Unit Dimensions - 3-10 Ton R-410A PKGD Unitary Cooling Rooftop Item: Al Qty: 1 ELECTRICAL / GENERAL DATA GENERAL (2)(4)(6) Oversized Motor Minimum Circuit Ampacity: N/A Maximum Fuse Size: N/A Maximum (HACR) Circuit Breaker: N/A Field Installed Oversized Motor Minimum Circuit Ampacity: N/A Maximum Fuse Size: N/A Maximum (HACR) Circuit Breaker: N/A Model: TSC048E Unit Operating Voltage: 187-253 Unit Primary Voltage: 208 Unit Secondary Voltage 230 Unit Hertz: 60 Unit Phase: 3 SEER N.A 13.0 Standard Motor Minimum Circuit Ampacity: 24.1 Maximum Fuse Size: 35.0 Maximum (HACR) Circuit Breaker: 35.0 INDOOR MOTOR Standard Motor Outsized Motor Field Installed Oversized Motor Number: 1 Number: N/A Number. N/A Horsepower: 1.0 Horsepower: N/A Horsepower: N/A Motor Speed (RPM): — Motor Speed (RPM): N/A Motor Speed (RPM): N/A Phase: 3 Phase: N/A Phase: N/A Full Load Amps: 5.0 Full Load Amps: N/A Full Load Amps: N/A Locked Rotor Amps: 32.2 Locked Rotor Amps: N/A Locked Rotor Amps: N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number: 1 Number: 1 Horsepower: 3.6 Horsepower: 0.33 Phase: 3 Motor Speed (RPM): 1075 Rated Load Amps: 14.6 Phase: 3 Locked Rotor Amps: 91.0 Full Load Amps: 2.0 Locked Rotor Amps: 6.6 POWER EXHAUST ACCESSORY (3) FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type R-410 Phase: N/A Type: Throwaway Horsepower: N/A Fumished: Yes Factory Charge Motor Speed (RPM): N/A Number 2 Circuit #1 7.4 lb Full Load Amps: N/A Recommended 20"x30"x2" Circuit #2 N/A Locked Rotor Amps: N/A NOTES: 1. Maximum (HACR) Circuit Breaker sizing is for installations in the United States only. 2. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. 3. Value does not include Power Exhaust Accessory. 4. Value Includes oversized motor. 5. Value does not include Power Exhaust Accessory. 6. EER is rated at AHRI conditions and in accordance with DOE test procedures. FLD = Fumished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 7 of 14 Installed by Others Weight, Clearance & Rigging Diagram - 3-10 Ton R-410A PKGD Unitary Cooling Rooftop Item: Al Qty: 1 RTU-4 CORNER WEIGHT INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 26.0 lb MOTORIZED OUTSIDE AIR DAMPER MANUAL OUTSIDE AIR DAMPER BAROMETRIC RELIEF 7.0 Ib OVERSIZED MOTOR BELT DRIVE MOTOR POWER EXHAUST HEATER REHEAT THROUGHT THE BASE ELECTRICAL (FIOPS) UNIT MOUNTED CIRCUIT BREAKER (FIOPS) UNIT MOUNTED DISCONNECT (FIOPS) POWERED CONVENIENCE OUTLET (FIOPS) HINGED DOORS (FIOPS) HAIL GUARD SMOKE DETECTOR, SUPPLY / RETURN NOVAR CONTROL BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET 167.0Ib O 101.0Ib (E) LENGHT (F) WIDTH 586.0 Ib 511.0 Ib B( 129.0 Ib DO 114.0 Ib 31" 19" NOTE: 1. CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2. TO ESTIMATE SHIPPING WEIGHT ADD 5 LBS TO NET WEIGHT. 3. BASIC UNIT WEIGHT DOES NOT INCLUDE ACCESSORY WEIGHT. TO OBTAIN TOTAL WEIGHT, ADD ACCESSORY NET WEIGHT TO BASIC UNIT WEIGHT. 4. WEIGHTS FOR OPTIONS NOT LISTED ARE <5 LBS. RIGGING AND CENTER OF GRAVITY WEIGHT CALCULATIONS: BASE UNIT WEIGHT....511 LBS ECONOMIZER 26 BAROMETRIC DAMPER07 PLENUM BOX 260 SLEEPER 224 TOTAL WEIGHT, LBS1028 FLD = Fumished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 8 of 14 Installed by Others Weight, Clearance & Rigging Diagram - 3-10 Ton R-410A PKGD Unitary Cooling Rooftop Item: Al Qty: 1 CLEARANCE 36" CLEARANCE 48" DOWNFLOW CLEARANCE 36" HORIZONTAL CLEARANCE 18" CLEARANCE 36" PACKAGED COOLING CLEARANCE ROOF OPENING UNIT OUTLINE 40" 68 3/16" PACKAGED COOLING 37" CLEARANCE FROM TOP OF UNIT 72" 44 1/2" DOWNFLOW TYPICAL ROOF OPENING FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 9 of 14 Installed by Others Accessory - 3-10 Ton R-410A PKGD Unitary Cooling Rooftop Item: Al Qty: 1 ECONOMIZER HOOD 12 1 /2" ECONOMIZER HOOD ACCESSORY ECONOMIZER HOOD 6 1/4" FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 10 of 14 Installed by Others Accessory - 3-10 Ton R-410A PKGD Unitary Cooling Rooftop Item: Al Qty: 1 BAROMETRIC RELIEF HOOD BAROMETRIC RELIEF HOOD 6 15/16" 9 1/8" BAROMETRIC RELIEF DAMPER HOOD ACCESSORY ECONOMIZER HOOD FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 11 of 14 Installed by Others BTL FILE COPY 19011 Woodinville Snohomish lid NE, Suite 100 Woodinville, \t',\ 98072-4315 Phone: (425) 814-8448 l as: (425) 821-2120 Structural Calculations for Tukwila Bldg B, RTU 14 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 2 2014 • City of Tukwila BUILDING DIVISION Support of Proposed HVAC Unit August 4, 2014 RECEIVED CITY OF TUKWILA AUG 2 6 2014 PERMIT CENTER kUL1OI1Q BTL 17924 — 140"", .Avenue NE, Suite 220 1W'oodinvillc,WK/.1 98072-4315 Phone: (425) 814-8448 Fax: (425) 821-2120 • Calculations BTL 1 •..(• 1\1.1 1 1 (i 17924 — 1401h Avenue NE, Suite 220 Woodinville, WA 98072-4315 Phone: (425) 814-8448 Fax: (425) 821-2120 Gravity Support 1. Mil 31/2X13@8'OC --I-- - - --'-- - - --1-- - - --'-- - - -- OUTLINE OF RTU-4 � SEE ENLARGED PLAN I I I V'gi FOR ATTACHMENT ! ▪ — . as N PLENUM EXISTING 8X8X81 SLEEPER ▪ imi ! ! 4X4COL I I I 21! ! li! ! al I I I I I I I I I I I MI I I I I I I I I I 1 I I I ON MN IN PARTIAL ROiF EQUIPMENA& FRAMING PAN I SCALE: 1/8" = 1=0" I! ! ! I I I I I I I I BYL ENGINEERING 19011 Wood-Sno Road NE, Suite 100 Woodinville, WA 98072-4436 Phone: 425-814-8448 Fax: 425-821-2120 C4.(c/< ZY `"l 0,67 Y K—rr 7. 7( ran=r jar CZ `;� ti o PIP It( /b �Y 5-0 r 7 /4/6-0(?.o ) /.lg(/,(;)/•.� ©'%j/c''�' O 5 / "//7 - . 3 ,•/2000 /,is.. r�- L`�. } 1 D.K 4/Y/6 pF FL, 5 / Cn . 1-/% Project: Designed By: Date. Project Number: Client: Scale. ' Page. Cr Z BTL 17924 — 1401h Avenue NE, Suite 220 Woodinville, WA 98072-4315 Phone: (425) 814-8448 Fax: (425) 821-2120 Seismic Support Tukwila Bldg B, RTU 14 Revision Date: 8/4/2014 Project Number Occupancy Category: II - Other Structures Seismic Use Group: I /E = 1.00 (Seismic Factor) IS = 1.00 (Snow Factor) I v, = 1.00 (Wind Factor) Site Class: S s = .1750. Si = 0.50'.';.,':. D F. = 1.00 Fv = 1.50 - Y;' IBC Table 1604.5 ASCE Table 20.3-1 ASCE Table 11.4-1 ASCE Table 11.4-2 Design Spectral Response Acceleration: SMS = FBSS = 1.50 SDs=%SMS = 1.00 SM1 = FvSi = 0.75 Sol = SM1 = 0.50 Tukwila Bldg B, RTU 14 Revision Date: 8/4/2014 Project Number ASCE 07-10: Chapter 13 ap = :_:`. 2.5 ':. (Table 13.5-1 or 13.6-1) Rp = 6.0 (Table 13.5-1 or 13.6-1) Seismic Forces Ip = i.0 v j (Section 13.1.3) zlh = Component Operating Weight: 1028 : Ibs Fp = 0.4 ap SDs Wp Rp/ Ip [1+2 (z/h)] ASCE Eq. 13.3-1 Fp = 514 Ibs <___ Fp need not exceed: Fp = 1.6 SDs Ip Wp ASCE Eq. 13.3-2 Fp = 1645 Ibs Fp shall not be less than: Fp = 0.3 SDs Ip Wp ASCE Eq. 13.3-3 Fp = 308 Ibs Dimensions: x = :` :44.25 in y = 69.875... in z= 36.25 • in Curb Height = : '5.5:!.: in Check Uplift: z Curb Height Fp Wr MOT = 12143 Ib-in MRESIST = 20470 Ib-in F.S. = 1.7 SHEAR = UPLIFT = 1.5 514 Ib 0 Ib ===> Anchors Only Required to Resist Shear Loads 1'EL ENGINEERING 17924 - 140th Avenue HE, Suite 220 Woodinville, WA DB072-4315 Plume: 425-B14-844B .Fax: 425.1321-2120 31c rle;e4c- (-67/1 51e-eper- - 51‘( 251 ....... • • ................... g 14 (4) 5g1telk = tijcr-w4P5 121 g 64 •5.7.4<IP 2-4 lo scewids " ........ F4 cH L /55 piK Project: Designed By: Date: Project Number: Client Scale: Page: 5-1 BTL ENGINEERING 19011 Wood-Sno Road NE, Suite 100 Woodinville, WA 98072-4436 Phone: 425-814-8448 Fax: 425-821-2120 A r7 G.(- 4(- TO gam lP 2 r , �J' i z 4 (� � G � c/?4.1 _�s (Ai ro 72- KG-14/ (2-,) ( <" /p u ki Mg rt ?z/ /b (1.7-) '-,;0 00 ( kin 1-/y uoc.)(5) 3 7 Project: Designed By: Project Number: Client: Scale: Date. Page: S BTL 17924 — 140'1, Avenue NE, Suite 220 Woodinville, WA 98072-4315 Phone: (425) 814-8448 Fax: (425) 821-2120 Details MS7FNRR/-0 R7Sb5 192 WITH 18.c 4ANGLE. SOW ANGLER) UNIT84SERAIL W/(2) 110SOPEW, SCREW SLEBJER IOSCREW, (2)SCREW ANGLES ONLONG SIX (4) TOTAL A IGL (16) TOTAL s[REWS. WEDEA15n4G SLEEPERS AS READ .2/Pr3LA:S301; TYPOF(4) OrrrINGER 9XT, TYPO(4) EOSIING SUPPLY/ REMAIN PL98M RTU-4 ATTACHMENT DETAIL NOT TO SCALE 1/2"HEXNUT, IYP. OF(2). 1/2'k8"GALVANIZED HANGER BOLT CHEMCURBPENETRA770NSEAL 12 GA. x2"STEEL ANGLE W/ (2) 1/2" HOLES ANGLE LENGTH AS REQUIRED. 3/8"x3"LAG BOLT ri EXIST7NGSLEEPER: (2) 4x8s FASTENED TOGETHER TO FORM8x8. TYP. OF(2) SLEEPERS /AGLB E.kISTINGPURLIN A - A (SLEEPER ATTACHMENT DETAIL, TYP. @ 14] LOCATIONS) NOT TO SCALE 1 City of Tukwila Department of Community Development 2/2/2015 MARK SMELTZFR 1012 CENTRAL AVE S KENT, WA 98032 RE: Permit No. M14-0170 ANDOVER EXECUTIVE PARK 698 INDUSTRY DR Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 3/31/2015. Based on the above, you are hereby advised to: 1) Ca11 the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 3/31/2015, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M14-0170 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 "EMIT CORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0170 DATE: 08/26/2014 PROJECT NAME: ANDOVER EXECUTIVE PARK SITE ADDRESS: 698 INDUSTRY DR X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works Alf\ Af 9- tq Fire Prevention 111 Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 08/28/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 09/25/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERFORMANCE HEATING & A/C TNC Page 1 of 2 0 Washington State Department of Labor & Industries PERFORMANCE HEATING & A/C INC Owner or tradesperson MILLER, DANIEL E Principals MILLER, DANIEL E, PRESIDENT ERDAHL, DARRIN, VICE PRESIDENT GOWIN, RICHARD L, VICE PRESIDENT (End: 04/26/2011) GOWIN, CONSTANCE F, VICE PRESIDENT (End: 11/15/2007) Doing business as PERFORMANCE HEATING & A/C INC WA UBI No. 600 601 386 1012 Central Ave S KENT, WA 98032 425-251-0356 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. PERFOHA15ORT Effective — expiration 12/30/1985— 04/30/2015 Bond DEVELOPERS SURETY & INDEM CO $12,000.00 Bond account no. 748802C Received by L&I Effective date 11/27/2007 10/01/2007 Expiration date Until Canceled Insurance American Fire & Casualty Co $1,000,000.00 Policy no. BKA56064545 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600601386&LIC=PERFOHA15ORT&SAW= 09/29/2014