Loading...
HomeMy WebLinkAboutPermit M14-0176 - SPEEA - SPLIT SYSTEM, FAN, LOUVER, BACKDRAFT DAMPER AND GRILLESSPEEA 15205 52 AVE S M14-0176 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 1157200016 15205 52ND AVE S Project Name: SPEEA MECHANICAL PERMIT Permit Number: M14-0176 Issue Date: 9/29/2014 Permit Expires On: 3/28/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: SPEEA PROPERTIES 15205 52ND AVE S , SEATTLE, WA, 98188 KEITH RICE 7717 DETROIT AVE SW , SEATTLE, WA, 98106 MACDONALD MILLER FACIL SOLUTIO PO BOX 47983 , SEATTLE, WA, 98146- 7983 Phone: (206) 407-2676 Phone: (206) 768-4180 MACDOFS980RU Expiration Date: DESCRIPTION OF WORK: INSTALL (1) SPLIT SYSTEM, INSTALL (1) EXHAUST FAN WITH ASSOCIATED LOUVER AND BACKDRAFT DAMPER. INSTALL (2) RETURN GRILLES AND MISC DUCT WORK PER PLANS. Valuation of Work: $6,500.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $285.10 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2014 2012 Permit Center Authorized Signature: Date: Q i (VIM I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: /�-� y \ ��-L ti Date: 9'/2 I/Li Print Name: ak ` cCS -e This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKWW..A Comm unity Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** King Co Assessor's Tax No.: 1157200016 Site Address: 15205 52ND AVE S TUKWILA, WA 98188 Suite Number: Floor: 1 & 2 Tenant Name: SPEEA New Tenant: ❑ Yes O..No PROPERTY OWNER Name: SPEEA Address: 15205 52ND AVE S City: TUKWILA State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: KEITH RICE Address: 7717 DETROIT AVE SW City: SEATTLE State: WA Zip: 98106 Phone: (206) 407-2676 Fax: (206) 407-2677 Email: keith.rice@macmiller.com MECHANICAL; CONTRACTORINFORMATION t,.' Company Name: MACDONALD MILLER Address: 7717 DETROIT AVE SW City: SEATTLE State: WA Zip: 98106 Phone: (206) 768-4278 Fax: (206) 768-4279 Contr Reg No.: MACDOFS980RU Exp Date: 01/03/2015 Tukwila Business License No.: BUS-0100868 1L/69.1, 9/0,1g (10.tCY2) 4Q-10 Valuation of project (contractor's bid price): $ 6,500 Describe the scope of work in detail: INSTALL (1) SPLIT SYSTEM, INSTALL (1) EXHAUST FAN WITH ASSOICATED LOUVER & BACKDRAFT DAMPER. INSTALL (2) RETURN GRILLES AND MISC DUCT WORK PER PLANS. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric 0 Gas ❑ ?s-(ti-{ Other: H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace > l 00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser 3 Thermostat Wood/gas stove Emergency generator Other mechanical equipment 2 Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATIONNOTE Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signatur �— _�' Date: 09/09/2014 Print Name: DARLA DOLL Day Telephone: (206) 768-4278 Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106 City State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS h, � ,:,,,,, ^„ PermitTRAK ACCOUNT I QUANTITY � a 4 � }ram G ?i" k �H, .. _. r PAID J�'n N $242.84 g 0 �`t M14 0176 Address 1520$52ND AVE 5 d�fb't'+� Apn: 1157200016Y r ^ $242.84 MECHANICAL $233.50 PERMIT FEE R000.322.100.00.00 0.00 $186.80 PLAN CHECK FEE R000.322.102.00.00 0.00 $46.70 TECHNOLOGY FEE $9.34 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R3095 R000.322.900.04.00 0.00 $9.34 $242.84 Date Paid: Wednesday, September 10, 2014 Paid By: MACDONALD-MILLER Pay Method: CHECK 4032 Printed: Thursday, September 18, 2014 8:40 AM 1 of 1 CSYSTEMS DESCRIPTIONS ermltTRAK Cash Register Receipt City of Tukwila ACCOUNT QUANTITY PAID 2.26 14-0176 Address: 15205 52ND AVE n: 1157200016 2 MECHANICAL $40.63 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PLAN CHECK FEE R000.322.102.00.00 0.00 $8.13 TECHNOLOGY FEE $1.63 !; TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R3175 R000.322.900.04.00 0.00 $1.63 $42.26 Date Paid: Monday, September 29, 2014 Paid By: MACDONALD-MILLER FACILITY SOLU Pay Method: CHECK 4045 Printed: Monday, September 29, 2014 12:10 PM 1 of 1 I?SYSTEMS CITY FORM NO 1 1912 ADOPTED BY DIVISION OF MUNICIPAL CORPORATIONS. W1Lq (Ste 2 CITY OF TUKWILA TREASURER'S RECEIPT NE 47843 0 i Date �� 1. 20 4 / 1908d ' Receiveof 104LVi Oh\. 1 A ' ,AA \A V , 2, � V }` 1�ry f ('DollarsFc)K 7 14 (;P Krk, eiYrMI _ 0 00 , ° I--. l iP I�1-1 w. LiUt -G b00 . 9-2- , W 2- o . r (Lk T L 600 , )7"2- -. q00 • ( . O . lij- TOTAL 2L10.— q9 BY AiettAIC % ( DEPT: Ol.%jam WHITE - Finance Dept. CANARY - Customer PINK - File ,J$ INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project:. c)P,e_e Type of inspe Lion: i t(tAA , , t✓ 1' AdIrs fl y 2.4� 5 2, f(e Date Called: Jco 06ft 1 A/ Special Instructions: / k.�' \X Date Wanted: (a.m.- p.m. Requester: hone No: 3 t — & r} V ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: CTM 1 AA (} c) P f Date:o ZZ_t REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 4*-( INSPECTION RECORD Retain a copy with permit INSPECTION NO, PERMIT NO, CITY OF TUKWILA BUILDING DIVISION C/ 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: 25PP. A- Type of Inspection: i c_.frr,4P ► A71—:0h/ Address: AI Date Called: Special Instructions: �� �,�/�� jp(A4l, r r, s ST? Al`14 pA. 2. r9J'' t :lies Li..5 Date Wanted: "_ (O — CO '' 4 4 ! ,a.m p.m. Requester: Phone No: Approved per applicable codes. QCorrections required prior to approval. COMMENTS: Inspector: 1 Date: It/ l n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0176 PROJECT NAME: SPEEA DATE: 09/10/2014 SITE ADDRESS: 15205 52 AVE S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: ft-T oO L& t1 Building Division Public Works AW' IA- D '\1 I i Fire Prevention Structural n Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 09/16/14 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 10/14/14 Approved Corrections Required El (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 MACDONALD/MILLER FAC SOI TNC Page 1 of 3 Washington State Department of Labor & Industries MACDONALD/MILLER FAC SOL INC Owner or tradesperson SIMONDS, DERRICK R Principals SIMONDS, DERRICK R, PRESIDENT WEBSTER, MARK E, VICE PRESIDENT NOEL, STEPHANIE W, MEMBER SIGMUND, FREDRIC, PRESIDENT (End: 01/04/2011) LOVELY, STEVE C, VICE PRESIDENT (End: 01/04/2011) HACK, RICHARD, SECRETARY (End: 01/04/2011) KOPET, TYLER, TREASURER (End: 01/04/2011) TURLEY, DOUGLAS, CHIEF EXECUTIVE OFFICER (End: 01/04/2011) TURLEY, DOUGLAS, CHIEF OPERATING OFFICER (End: 01/04/2011) GOUGH, DAVID ANTHONY, DIRECTOR (End: 08/29/2014) Doing business as MACDONALD/MILLER FAC SOL INC WA UBI No. 602 254 260 PO BOX 47983 SEATTLE, WA98106 206-768-4180 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. MACDOFS980RU Effective — expiration 12/31 /2002— 01 /03/2015 Active. Meets current requirements. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602254260&LIC=MACDOFS980RU&SAW= 09/29/2014 J:\7314\6795 SPEEA — TAB 04, 2014 4:00:41 PM Thursday, September ABBV A AC AD AFF AL BDD BOB BOD BOTT BTU BTUH BWG BWR C CAP CC CFM CHWR CHWS COMB CONN CWR CWS DB DIFF DMPR DN EC EGG EER ELEV EMS FULL NAME COMPRESSED AIR LINE AIR CONDITIONING UNIT ACCESS DOOR (WALUROOFIDUCT - SEE DRAWING) ABOVE FINISHED FLOOR ALUMINUM BACKDRAFT DAMPER BOTTOM OF BEAM BOTTOM OF DUCT BOTTOM BRITISH THERMAL UNITS BRITISH THERMAL UNITS PER HOUR BOTTOM WALL GRILLE BOTTOM WALL REGISTER CONDENSATE CAPACITY CONTROLS CONTRACTOR CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY COMBUSTION CONNECT CONDENSER WATER RETURN CONDENSER WATER SUPPLY DUCT BOARD DIFFUSER DAMPER DOWN ELECTRICAL CONTRACTOR EGGCRATE ENERGY EFFICIENCY RATIO ELEVATION ENERGY MANAGEMENT SYSTEM ABBV ESP EXH EXTR FAC FD FLA FOB FOT FRD FSD G GALV GC GPM GR GWB HG HP HWR HWS ID INT LIQ M-M MBH MC MCA MD MIN MT MUA NOM FULL NAME EXTERNAL STATIC PRESSURE EXHAUST EXTRACTOR FIRE ALARM CONTRACTOR FIRE DAMPER FULL LOAD AMPS FLAT ON BOTTOM FLAT ON TOP FRICTION DAMPER FIRE SMOKE DAMPER GAS LINE GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GRILLE GYPSUM WALL BOARD HOT GAS LINE HORSE POWER HOT WATER RETURN HOT WATER SUPPLY INSIDE DIMENSION INTERLOCK LIQUID LINE MACDONALD-MILLER ONE THOUSAND BTUH MECHANICAL CONTRACTOR MINIMUM CIRCUITAMPACITY MOTORIZED DAMPER MINIMUM MOUNT MAKE-UP AIR NOMINAL ABBV OSA OBD OD RA REG REQ'D RIO SA SCD SD SL SM SP SS SSSC STL SUC SUSP T'STAT TC TOD TOS TV TWG TWR TYP UNO VD VFD 0 FULL NAME OUTSIDE AIR OPPOSED BLADE DAMPER OUTSIDE DIMENSION RETURN AIR REGISTER (GRILLE WITH DAMPER) REQUIRED ROUGH IN ONLY SUPPLY AIR SMOKE CONTROL DAMPER SMOKE DAMPER SOUND LINING SHEET METAL STATIC PRESSURE START/STOP SOLID STATE SPEED CONTROLLER STEEL SUCTION LINE SUSPENDED THERMOSTAT TEMPERATURE CONTROL TOP OF DUCT TOP OF STEEL TURN VANES TOP WALL GRILLE TOP WALL REGISTER TYPICAL UNLESS NOTED OTHERWISE VOLUME DAMPER VARIABLE FREQUENCY DRIVE VOLTAGE PHASE & DUCT DIAMETER DESCRIPTION SYMBOL DESCRIPTION SYMBOL BARE SHEETMETAL 14x12 ROUND SHEETMETAL WRAPPED W/ INSULATION (2") 120W SOUNDLINE SHEETMETAL (1" LINING) 14x12SL CLEANROOM QUALITY DUCTWORK 14x12C SHEETMETAL WRAPPED W/ INSULATION (2") 14x12W BARE FLAT OVAL SHEETMETAL 14x120 BARE ROUND SHEETMETAL 120 FLAT OVAL FLAT SHEETMETAL W/ INSULATION (2") 14x120W EXPOSED QUALITY SHEETMETAL 14x12Q DUCTBOARD (1" FIBERGLASS) 14x12DB EXAMPLE OF NEW 1 4x1 2 EXAMPLE OF NOT IN CONTRACT (NIC) 14x12 EXAMPLE OF DEMO EXAMPLE OF EXISTING xxxXXXX 1 4X 12 FLEX DUCT FLEX CONNECTOR -%nnnnr- SYMBOL MANUFACTURER & MODEL NUMBER SIZE TYPE NOTES SIZE \JCFM SHOEMAKER 701-MA AS NOTED T-BAR LAY -IN DIFFUSER M-M METAL EGGCRATE 12/24 RETURN/EXH M-M METAL EGGCRATE 24/24 RETURN/EXH UNIT NO. EF-1 AREA SERVED AN CLOSET MFG & MODEL NO. BROAN L150 TYPE IN -LINE CFM 157 ESP 0.125 RPM 710 FLA 1.3 HP VOLT/PH 11511 BDD YES WT LBS 23.1 NOTES NEW, 1-6 n NOTES: 1. POWER WIRING AND DISCONNECT SWITCH BY ELECTRICAL CONTRACTOR. 2. MOTOR STARTER BY ELECTRICAL CONTRACTOR. 3. SPRING ISOLATORS. 4. LOW NOISE CONSTRUCTION 5. CONNECT TO LINE VOLTAGE THERMOSTAT, HIGH TEMP - MOUNT AT 48" AFF, SET AT 80° F 6. CONNECT TO NEW EXTERIOR WALL EXHAUST TERMINATION, WITH BACKDRAFT DAMPER UNIT NO. MANUFACTURER INDOOR UNIT OUTDOOR UNIT MODEL NOM. TONS CFM HSPF/ SEER ELECTRIC VOLT/PH AL WT MCA LBS MODEL ELECTRIC CFM VOLT/PH AL WT MCA LBS NOTES AHU-1, CU-1 FUJITSU ASU12RL2 400 16.00 115 1.0 16 AOU12RL2 1013 115 15.0 69 1,2,3,4,5 NOTES: 1. PROVIDE WITH T'STAT (MT. ON WALL), WHITE FINISH, CONDENSATE PUMP 2. INSTALL IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND DETAILS ON DRAWINGS. 3. PROVIDE 3/4" TYPE L COPPER CONDENSATE DRAIN TO BUILDING EXTERIOR 4. INDOOR UNITS FACTORY WIRED AND CIRCUIT PROTECTED FOR SINGLE POINT ELECTRICAL CONNECTION. 5. CONFIRM EQUIPMENT VOLTAGES ON SITE, CONFIRM SINGLE PHASE PRIOR TO EQUIPMENT ORDER. UNIT NO. MFG & MODEL NO. HP-1 TRANE 4WCC3048A3000A HP-2 TRANE 4WCC3030B1000A HP-3 TRANE 4WCC3024B1000A NOM TONS 4.0 2.5 2.0 HEAT MBH 47.0 28.0 22.0 CFM 1600 1000 800 ESP 0.5 0.5 0.5 FAN HP 3/4 1/2 1/2 OA CFM 240 150 HP-4 HP-5 TRANE 4WCC3024B1000A TRANS 4WCC303061000A / i \ HP-6 TRANE 4WCC3030B1000A HP-7 TRANE 4WCC3030B1000A 2.0 2.5 2.5 2.5 22.0 28.0 28.0 28.0 800 1000 1000 1000 0.5 0.5 0.5 0.5 1/2 1/2 1/2 1/2 120 120 150 150 150 HSPF/ COP 7.7/ 7.7/ 8.0/ 8.0/ 7.7/ 7.7/ 7.7/ EER/ SEER /13.0 /13.0 /13.0 ELECTRICAL VOLT/PH AUX HTR KW 208/3 208/1 208/1 7.5 6.0 3.8 MCA 54.0 61.0 39.0 WT LBS 425 321 357 NOTES EXIST EXIST EXIST /13.0 /13.0 /13.0 208/1 208/1 208/1 208/1 3.8 6.0 6.0 39.0 45.0 61.0 61.0 357 321 321 321 EXIST EXIST EXIST EXIST NOTES: . THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2012 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2012 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM. 4. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2012 WSEC. - DUCT WRAP, WHERE INDICATED, SHALL BE 1 1/2" 0.75 LB/CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R-4.2 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB/CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-4.2 MIN.). - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R-4.3 MIN.). AIR DUCT (R-4.3 MIN.). 6. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON -PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED OTHERWISE. 7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2012 IBC. 8. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE/SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 717.5 OF THE 2012 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 717,6.2.1 OF THE 2012 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE/SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE. 9. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 10. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE 18" X 18". 11. MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. 12. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 13. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 14. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416 AND WITH LEED NC-2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. 15. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER REVIEWED FOP, CODE COMPLIANCE APPROVED SEP 2 4 2014 AT City of u >rifa BUILDIN D 1/leln APN# 115720-0016 SITE ADDRESS: 15205 52ND AVE S 98188 LEGAL DESCRIPTION: BROOKVALE GARDEN TRS PARCEL A OF TUKWILA SP NO 79-32-SS REC NO 7912050555 SD PLAT DAF - POR TR 1 BROOKVALE GARDEN TRS LY WLY OF 52ND AVE S LESS N 30 FT OF VAC ST ADJ LESS W 20 FT THOF FOR CO RD LESS S 51.00 FT THOF ADD (1) NEW 1 TON SPLIT SYSTEM TO VESTIBULE. ADD (1) NEW EXHAUST FAN AND DOOR LOUVER TO AN CLOSET ADD (2) NEW RETURNS TO 2ND FLOOR OFFICES TITLE PROJECT ENGINEER ACCOUNT MANAGER PRODUCTION MANAGER SHEET METAL FOREMAN AIR BALANCE FOREMAN FACILITIES DIRECTOR NAME ERRYN EDRINGTON MIKE REICHERT TIM FELTON RON LANDBERG MARTIN PASCUAL COMPANY MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER SPEEA PHONE NUMBER 206- 253-798-5080 206-768-4216 206-407-2692 206-571-2661 204-433-0995 X 126 EMAIL @MACMILLER.COM ERRYN.EDRIN GTON @MACMI LLER.COM MIKE.REICHERT@MACMILLER.COM TI M.FELTON@MACM I LLER.COM RON.LANDBERG@MACMILLER.COM MARTINP@SPEEA.ORG NAME TITLE NAME TITLE TM0.01 DM2.01 SCHEDULES -HVAC 1ST FLOOR DEMO PLAN - HVAC TM2.01 1ST FLOOR PLAN - HVAC TM2.02 2ND FLOOR PLAN - HVAC SEPARATE Rp PERMIT REQ ❑ Mechanical Electrical Plumbing Gas Piping !A ►�1 City of Tukwila BUILDING DIVISION S 152nd St 518 S 151 st Si 51 st Ave S 52nd Ave S Southcenter Blvd FILE COPY Permit No. A 1 n review approval is subject to errors and omissions. proval of construction documents does not authorize violation of any adopted code or ordinance. Receipt f pproved Field Copy and conditions Is acknowledged: B n y: Date: _ 9 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan v uhmittal and may include additional plan review fees. VICINITY MAP NO SCALE City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 1 0 2014 PERMIT CENTER Mt'4 0 vRo• sa5 o) O IM COI` 0) Q ° 0 I.-_ N N � _(LL CIO 0 GO en a)o 0 _ 0)> CO C.) 0o "dio NCO N c �,;;j� di �G LL N. D- ENGINEER: K RICE CHECKED BY: B GEZON CAD: J HACKNEY DRAWING NUMBER: C-1980-73 SHEET NUMBER: 1 I I I I I I rn cV I tp 0 .macmiller.com WA Lic No: MACDOFS980RU REVISIONS: W 0 REVISIONS: z 0 0 z 0 0 Ct 0 LL 0 L!J U) U) LAST REVISED: 08-29-14 DATE PLOTTED: 08-29-14 ISSUE DATE: 08-29-14 146795-00 TM0.01 J:\7314\6795 SPEEA — TAB Deficiency List Repairs — S b7\ D S 212' - 2Y4" 1 §3'-4 )1 S0� Cf) 1 I _fp �R B VD MI+ REVIEWED FOR CODE COMPLIANCE APPROVED SEP 24 2014 City of Tukwila BUILDING DIVISION 170 RECEIVED CITY OF TUKWILA SEP 1 0 2014 PERMIT CENTER W 0) z _cs O V O 0ct 0 w ENGINEER: K RICE CHECKED BY: B GEZON CAD: J HACKNEY DRAWING NUMBER: C-1980-73146 SHEET NUMBER: .macmiller.com co O (Y 0 0 H cc a.ICJ WA Lic No: MACDOFS980RU Lv a 0 REVISIONS: IJ J 0 0) Z 0 z 0 U U) z 0 U 0 LL 0 W LAST REVISED: 08-29-14 DATE PLOTTED: 08-29-14 ISSUE DATE: 08-29-14 795-00 TM0.01 S B 4/18 12" 0 1" SL SM 365 CFM FCU-3 20/16 "SLSM- 535 CFM --,- 12/12 MID-S ONE WAY THROW 450 CFM EA ��O ANEM. 10/10 S3HD 1201CFM 400. CFM 3/4" COND. LINE 175 FM MEETING R0O! `j RFCEPTION ANEM. 8/8 S3HOD 125 CFM (7) ANEM. 10/10 S3HD 170 CFM —24/12 570 CFM :ON1 1=tv1 PRINT RM. 285 C M 0 24/12 D. 14/12 D.B. 165 CFM EF #01 ?4/12 200 CFM 19/15 SL SM 8"0 165 CFM `120 CFM ANEM-6/6 MRD-S 40 CFM To ERVICE NK WO tiiL N ANEM. 10/10 S3HOD 220 CFM s nfi ANEM. S3HOD i' CFM ANEM. 10/10 S3HOD 240 CFM 170 CFM ANEM. 10/10 S3HD 65 CFM 6" 0 10 `-:DR REFRI GERANT LINES UP TO ROOFTOP UNIT (3 TYPICAL) \10 3/4" COND. LINE I._OUNO 24/12 ANEM. 10/10 MRD-S 275 CF 310 CFM 230 CFM 380 CFM REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 4 2014 City of Tukwila BUILDING DIVISION VLLw-OI7& RECEIVED CITY OF TUKWILA SEP 1 0 2014 z I I I I I I I I I I I I I I I I rn N CO 0 0 0 w 0_ I I I I I 1<- OOR DEMO PLAN ENGINEER: K RICE REVISIONS: w 0 REVISIONS: Z 0 0 F- Z 0 0 0 u_ 0 w �v J VJ LAST REVISED: 08-29-14 CHECKED BY: DATE PLOTTED: B GEZON 08-29-14 CAD: ISSUE DATE: J HACKNEY 08-29-14 DRAWING NUMBER: 0-1980-73146795-00 SHEET NUMBER: DM2.01 PERMIT CENTER 1/8" = 1'-0" J:\7314\6795 SPEEA - TAB NEW 10X8 TRANSFER GRILLE IN EXISTING DOOR B' 2014 10:59:47 AM f_.._, 4/18 12" 0 1 " SL SM 365 CFM 20/16 1" SL SM 535 CFM 12/12 MRD—S ONE WAY THRO' 450 CFM EA ANEM. 10/10 S3HD 120 CFM -EF-----1 DROP TO BLLY BPiND OF SIDING 0 0 NEW EXHAUST 9' ABOVE G' TERMINAT ON UND L L ANEM. 10/10 S3HD 170 CFM \I 24/12 + % 570 CFM 14" 0 01 SL SM 0 `175 CFM - T MEETING RO VIS 7) 585 CFM N 1-. I M CU-1 EF #01 4/ 1-2 1" SL 200 CFM 19/15 .L SM -- 8"0 / 165 CFM 8 JrN20 CFM ANEM-6/6 MRD—S 40 CFM 0 ERVICE NK uP 11/11 S AC-1 12''0 24/12 D. 14/12 D.B. 165 CFM ANEM. 10/10 S3HOD 220 CFM MOUNT CON .DENSIN UNITON NEW CONCRETE PAD NEW REFRIGERANT PIPING 1 /4" LIQUID, 3/8" GAS PREINSULATED OUTDOOR LINES LOCATE UNIT BEHIND SCREENING BUSHES CU-1 GROUND LEVEL ET ANEM. 10/10 S3HOD 240 CFM R < I D ( Ik �170 CFM CJ 113 ANEM. 10/10 S3HD 65 CFM (_0 RAC F REFRIGERANT LINES UP TO ROOFTOP UNIT (3 TYPICAL) 3/4" COND. LINE _OUNCE SCREENING BUSHES ANEM. 10/10` MRD—S 275 CF14\ 310 CFM 230 CFM 380 CFM NEW 6" EXHAUST GRILLE REVIEWED FOR CODE COMPLIANCE APPROVED s 2 4 2014 C;tv 'f Tukwila BUILOIiNi DIVISION Mly 170 RECEIVED CITY OF TUKWILA SEP 1 0 2014 PERMIT CENTER Z C9 Cr) 03(0 rnNs a� a)0 N N U ALL CI o f0 C.) C Q O CO N N r-- L D_ 0 0 cc w a_ I I I I I I< OOR PLAN ENGINEER: K RICE CHECKED BY: B GEZON CAD: J HACKNEY DRAWING NUMBER: 0 co 0 (/) LL 2 Z U REVISIONS: w 0 REVISIONS: z 0 0 z 0 U 0 0 W (/ JJ VJ LAST REVISED: 08-29-14 DATE PLOTTED: 08-29-14 ISSUE DATE: 08-29-14 0-1980-73146795-00 SHEET NUMBER: TM2.01 1/8" = 1'-0" OI 0 • List Repairs — EE\00\2 c c G J:\7314\6795 SPEEA — TAB ANEM. MRD-S r 12/8 D.B. 6/24 EC. DIPECTo( 12/24 D.B. &R DROPS -27T2 355 CFM CO C3) a. a N s N 0 E r L0011080 0, 7 10X10 8/2 2/24 EC 24 EC 10X10 A 240 10X10 0210 -_-----1 �- r - r --- &R DROPS O" 1 /24 E ` . 350 CFM_ 18/246„ 12i-D--B :;R DROPS LLL`+/. 12/24 EC (TYP 71 2 24 D.B & __DROP? ANEM. 10/10 S3HOD 255 CFM E!) 370 CFM EA 1 1 /,p0C. 1..2/6._ D ANEM. 10/10 S3HOD 270 CFM 10X10 i Esc $Ei fE 10X10 A v—v190 INSTALL PER M.M. STD SA- STORACL. -= TL 8X8 (T5YP 2) REFRIGERANT LINES DN. TO FAN -COIL UNIT (3-TYPICAL) B PS REVIEWED FOR CODE COMPLIANCE APPROVED SEP 24 2014 City of Tukwila BUILDING DIVISION filly-/ ►7 RECEIVED CITY OF TUKWILA SEP 1 0 2014 PERMIT CENTER E9z 1/8" = 1'-0" L co o co 0 2 00 ' H N _13 3 Cn li OM a Lc 1 1 1 1 1 1 1 1 1 1 I •-1 rn CV I 0 2ND FLOOR PLAN ENGINEER: K RICE CHECKED BY: B GEZON CAD: J HACKNEY 0 IiJ K REVISIONS: REVISIONS: z 0 0 z 0 0 0 0 W C0 G0 LAST REVISED: 08-29-14 DATE PLOTTED: 08-29-14 ISSUE DATE: 08-29-14 DRAWING NUMBER: C-1980-73146795-00 SHEET NUMBER: TM2.02