Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M14-0193 - WENDY'S RESTAURANT - HOOD, GREASE DUCT AND FAN
WENDY'S RESTAURANT 16300 WEST VALLEY HWY M14-0193 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 0005800041 16300 W VALLEY HWY Project Name: WENDY'S RESTAURANT MECHANICAL PERMIT Permit Number: M14-0193 Issue Date: 10/27/2014 Permit Expires On: 4/25/2015 Owner: Name: Address: Contact Person: Name: WENDYS INTERNATIONAL INC P 0 BOX 256 , DUBLIN, WA, 43017 MIKE SCHEFFLER Address: 11447 120 AVE NE , KIRKLAND, WA, 98033 Contractor: Name: METRO AIR INC Address: 11021 128 PL NE , KIRKLAND, WA, 98033 License No: METROAI995RC Lender: Name: Address: Phone: (425) 922-9198 Phone: (425) 889-8224 Expiration Date: 12/3/2015 DESCRIPTION OF WORK: INSTALL NEW TYPE I HOOD, WELDED GREASE DUCT, AND NEW EXHAUST FAN. Valuation of Work: $6,500.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $126.76 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2014 2012 Permit Center Authorized Signature: (Ay. 1,4 Date: `Il -s;7'1 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name:C-5 \(so,5� �r- Dat(),-)l r - This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***MECHANICAL PERMIT CONDITIONS*** 2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Type 1 Hoods, the required grease duct leakage test and (light test shall be performed by a special inspection and testing agency in accordance with I.M.C. Chapter 5. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 11: ***FIRE DEPARTMENT PERMIT CONDITIONS*** 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire -extinguishing system installed in accordance with this code. (IFC 904.2.1 and IFC 904.11) Automatic fire -extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) 14: Type I hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. (IMC 507.2.1.1) 15: All new automatic fire -extinguishing systems and all modifications to existing automatic fire -extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 16: Local U.L. central station supervision is required. (City Ordinance #2437) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 18: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 19: Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 20: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0701 ROUGH -IN MECHANICAL Tenant Name: �� l PROPERTY OWNER Name:`\-`�\ Address:\,\ ` `9 ,%r CitQ.. ate: OV CONTACT PERSON - person receiving all project communication Name:Ml '`'`\., s\s� \ n ,\\L\\.„\,-) Address: \a, p�,,1/4, , City: \(' 1 \ 1 State: \ _ ,. Zip0\ ar �. n 1�s�0�� V� r Phone\ .,C .._GA jFFax: Vl2s- (tzs ,..,---AN Email: {-1- c *, e Q\Q Lvy*,c S\ t.t.Ak.)\ CITY OF TUK: ;A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 littp://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION \���� %.DA King Co Assessor's Tax No.: Site Address: \� Suite Number: Floor: New Tenant: ❑ Yes ❑.. No MECHANICAL CONTRACTOR INFORMATION Company } Name:f mt7-1, � nln ,�� Address\\L��) -\ tJ g4 5. Cit} ►,1 c1\ cm,), \ State ZipC\ Phon - F)\41A Fa#NY' `OS 0\9\ 1 Contr Reg No.:C"-Q. iC)c,:trFRpMat \ 1----,Tukwila Business License No.: ��'.`T�l s 1 Valuation of project (contractor's bid price): $ , V V Describe the scope of work in detail: C �� J Cl i& exkiA \'\ \ 1 Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement ❑ Fuel Type: Electric ❑ Gas ❑ Other: H: Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct 11 Ventilation system Hood and duct r Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Signature. Print Name: �1 BUILDING OWNER ORRI��GENT: Mailing Address: \\' -\\© £ J Date\\\ 1� Day Telephone\S ("PD City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 DESCRIPTIONS ermitTRAk Cash Register Receipt City of Tukwila ACCOUNT QUANTITY PAID 126:, 14=0193 Address: 16300 W VALLEY HWY pn: 0005800041 126. MECHANICAL $121.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $65.00 PLAN CHECK FEE R000.322.102.00.00 0.00 $24.38 TECHNOLOGY FEE $4.88 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R3273 R000.322.900.04.00 0.00 $4.88 $126.76 Date Paid: Thursday, October 09, 2014 Paid By: METRO AIR INC Pay Method: CREDIT CARD 033474 Printed: Thursday, October 09, 2014 2:51 PM 1 of 1 cRWYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. ,J CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 3 Project: t Type of Inspection:. _ ici Address: /iP 9J U,1�tte i Date Called: /fite ki ,J Special Instructions: ` Date Wanted: I , —4 -14 a.m_ Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 0491 II'' 1 InspOctor: Date:it 4 /4 REINSPECTION FEE\ItEQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. M/4-1 /'i3 INSPECTION NO. PERMIT NO. it ,lit CITY OF TUKWILA BUILDING DIVISION [� l� 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 INSPECTION RECORD Retain a copy with permit Project: r j / 4.S Type ofllnspection: , i0r!i_.-1. /" ,� r A_1,- Address: t J 1(D_CO3 W. A4AtY Date Called: Special Instructions: ( / I rIL_.,�'`12L- Date Wanted: j !? - c �3"tri: _� 1 p.m. Requester�:,,� / Phone No: r 7/`1t- Approved per applicable codes. Corrections required prior to approval. COMMENTS: t «T) P , J.s?` (174 ./e J-> r ' !'; Ar. f Inspector cx_A Ai Q), Date:l Q 3 - /4 REINSPECTION FEE REQUIRED.`Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION {\ 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 M f4-L " 1_3 Project: /_ I ( LAJ • Type of Inspection: J Address: f i i n 3 I)a LA ` LiA-4 l (Li Date Called: _ __ .7� �_) �-.� { 1 A 10 Special Instructions: i Date Wanted: 1 a.m. Requester: • Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: R `r /' (1 I/ __ ..-: ...) C. -( L-J / , 7,J ----_-----, 7 , \ I /A 2 r 7 _../ Inspector: , A6^4A) �\ Date: , f 4- REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER /! / - 2- E! / i N -- O 19 '3 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: e4' S" Type ofilnnsp,C�tion:/ it C. r i / of °"` G Address: / Suite #: 5/0 ' l /4/ Contact Person: Special Instructions: if Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: /41/3-2w/ . F, /e 4cc, " 75y-e.- d , 7/ /., � ./ - IkOal zp.<7,4_,." 6 4 , , . ,,,N,1 -71--;\,, .d14"-e .<:i7A 4 0 v rtst n r. `� V ) F / +�{1 /Ist-�✓Cp Ir. ./ 4 14-/g.J �%.s? f./1'ti,-J/ �1 /; w�.t ! X L;; t'. C1/24-'7 ( f Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspectors ,,,i c 3 Date: //hy/ / Hrs.: /. 6 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Address: Company Name: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 FILE COPY U, M \ — Tam *t..1. WOE INSTALL TEMP SENSOR ON RIGHT SIDE OF DUCT ■e PLAN VIEW ,.LIP FLANGE r— ARE SYSTEM CABINET 34.5" I I J L� 4" 2 1/4" 49" 4 4 3"R RIGHT BODY END 32" 4'-6" 9'-0" GL-L FIRE CABINET EXHAUST COLLAR (RATED FOR 1500 F.P.M. MIN. TO 2200 F.P.M. MAX.) -UNISTRUT �CLOSURE PANEL (FRONT/LEFT SIDES ONLY) w/ ACCESS TO FIRE PROTECTION (ACCESS DOOR IS STANDARD HEIGHT) 0 N 00 LV------TTI II II M STAINLESS STEEL FILTERS GREASE CUP /REVIEWED FOR CODE COMPLIANCE APPROVED OCT 23 2014 City of Tuk'wita I BUILDING DIVISION " STAINLESS STEEL SPACERS WELDED AT BOTH ENDS OF FILTER BANK. USE ALTER SIZE TO DETERMINE SIZE OF EACH SPACER +i LEFT SECTION VIEW THROUGH GL—L U.L. 710 .\ Exploded Yew J NOTE: 23" HIGH ENCLOSURE PANEL @LEFT & FRONT OF HOOD WITH STANDARD FIRE CABINET REMOVABLE DOOR. WENDY'S ITEM NO. L0402-3VAT TAG: SB3183 FRYER HOOD EXHAUST COLLAR CHART COLLAR 1 COLLAR 12"X8" CFM PER ACTIVE FOOT 128 TOTAL CFM 1175 STATIC PRESSURE (IN.WG) 0.45" RECEIVED ITY OF TUKWII'1 OCT 092014 PERMIT CFNTFR SPECIAL NOTES TO MECHANICAL TRADES GENERAL : - GL SERIES VENTILATORS ARE LISTED AS A GREASE EXHAUST HOOD. - FILTERS ARE LISTED AS APPROVED GREASE ALTERS. DUCT WORK : - ALL DUCT WORK BEYOND VENTILATOR EXHAUST COLLAR OPENING SHALL BE LIQUID TIGHT AND CONFORM TO ALL APPLICABLE CODES. - TO DETERMINE TOTAL SYSTEM STATIC PRESSURE, ADD EXHAUST OUTLET STATIC PRESSURE TO CALCULATED DUCT WORK SYSTEM STATIC PRESSURE. - DUCT COLLARS ARE SIZED FOR SPECIFIED AIR VOLUMES TO MEET APPLICABLE CODES. INSTALLATION : - ALL EXHAUST VENTILATORS MUST BE INSTALLED LEVEL AND PLUMB. - INSTALL UNIT(S) WITH CLEARANCES TO ADJACENT WALLS AS REQUIRED TO CONFORM TO All LOCAL CODES AND INSPECTION REQUIREMENTS. NOTE : ALL WALLS SHOWN ON DRAWINGS ARE ASSUMED TO BE NON-COMBUSTIBLE. - EXHAUST AIR VOLUMES ARE RECOMMENDED FOR THE PROPER FUNCTION OF THE COOKI MENT SPECIFIED. CONDITIONS - ACTION AIR SHALL NOT BE RESPONSIBLE FOR IMPROPER FUNCTION DUE TO INCORRECT STATIC PRESSURE OR UNBALANCED AIR CONDITIONS. HALTON MODEL: GL-L FRYER HOOD SPECIFICATIONS: MATERIAL: 18 GA., S.S. FINISH: #4 FILTERS: U.L. LISTED STAINLESS STEEL BY ACTION AIR (4) 15.5" High X 24.5" Long ARE SYSTEM: ANSUL WET CHEMICAL THIS DRAWING IS THE PROPERTY OF ACTION AIR AND CAN BE REPRODUCED ONLY BY PERMISSION. IN WHICH CASE. ALL DRAWINGS MUST BEAR THE NAME ACTION NR THIS DRAWING IS NOT TO BE SCALED Balton CARE FOR INDOOR MR Tukwila WA RANGE/FRYER HOOD DRN. BY: LR SCALE: NTS DATE PROJECT No.: 10/6/14 I SB11 DWG. No.: 2 OF 5 MIDI - 0l°�3 FAN UNIT NO. TAG FAN UNIT MODEL # CFM ESP. RPM H.P. 0 VOLT FLA WEIGHT (LBS.) SONES 1 NCA14FA 1800 0.700 1054 0.750 3 208 2.7 134 10.1 FAN UNIT NO. TAG OPTION (Qty. - Descr.) 1 1 - Grease Box 1 - Extra Set of Belts 1 - Hinge Kit - Ships Loose for Curb Supplied by Others FAN ACCESSO FAN UNIT NO. TAG EXHAUST SUPPLY GREASE CUP GRAVITY DAMPER WALL MOUNT SIDE DISCHARGE GRAVITY DAMPER MOTORIZED DAMPER WALL MOUNT 1 YES FAN #1 NCA14FA - EXHAUST FAN 30 1/2 l 33 3/4 REASE DRAIN H-14 7/B— 21 24 3/4 DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) 23 FEATURES: - ROOF MOUNTED FANS - RESTAURANT MODEL - UL705 AND UL762 - AMCA SOUND AND AIR CERTIFIED - WIRING FROM MOTOR TO DISCONNECT SWITCH - WEATHERPROOF DISCONNECT - HIGH HEAT OPERATION 300•F (l49•C) - GREASE CLASSIFICATION TESTING SEPARATE PERMIT REQUIRED FOR: 0 Mechanical CPElectrical Irblumbing e2s Piping at,/ of Tukwila Blin DING DIVISION NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300•F (149•C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. ABNORMAL FLARE-UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600•F (316•C) FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. OPTIONS FILE COPY Permit No. VtS Plan review approval is subject to errors end omissions. Appnoval of construction documents does not authorize the violation of any adopted code or ordinance. Rapt of approved Field Copy and conditions is edge Date:�`�\�� 1 t� City of Tukwila BUILDING DIVISION GREASE BOX EXTRA SET OF BELTS HINGE KIT - SHIPS LOOSE FOR CURB SUPPLIED BY OTHERS REVISIONS No chances shall he made to the scope of work without prior approval of I ' u!CT"v'i°a Building Division. 6 f ` ` " : Flay:s:ons will require a new plan submittal i and may include additional plan review fees. REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2 3 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 092014 PERMIT CENTER M(L1O1t1, CAPnvsii, JOB Wendy's Exhaust Fan LOCATION Kirkland, WA, DATE 10/7/2014 JOB # 2098273 DWG# 1 DRAWN BY ryan85 REV. SCALE 3/8' = 1'-0' cExhaust Fan Wiring JOB 2098273 - Wendy's Exhaust Fan DRAWING NUMBER EXH2098273-1 SHIP DATE 7/29/2014 MODEL NCAI4FA 1 2 AK---� �K-----I 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 L —'— J GR SW-01 Installed Options Component Identification Label Description Location MT-01 Fan Motor [20 SW-01 Main disconnect switch [20 MOTOR INFO. EXHAUST 0.75HP-208V-3P-2.7FLA MOTOR/CONTROL EA L MCA: 3.4A INFORMATION MOTOR/CONTROL MOP, 15A NOTES - — — - DENOTES FIELD WIRING DENOTES INTERNAL WIRING WIRE COLOR BK - BLAO BL - BLUE BR - BROWN OR - ORANGE RD - RED WH - WHITE YW - YELLOW GR - GREEN GY - GRAY PR - PURPLE PK - PINK 14 Morgan ThermalCeramics FILE COPY Permit No. FireMaster° FastWrap° XL Datasheet Code US: 7-14-236 MSDS Code US: 406 © 2009 Morgan Thermal Ceramics, a business within the Morgan Ceramics Division of The Morgan Crucible Company plc Grease Duct Enclosure System Air Ventilation Duct Enclosure System Product Data & Installation Guide 1. Product Description FireMaster® FastWrap XL is a flexible blanket composed of high temperature fibers classified for applications to 2192°F (1200°C) and fully encapsulated in a durable glass fiber reinforced foil facing for easy handling and installation. FastWrap XL is UL and ULC Listed for 1 and 2 hour fire resistive enclosure protection, zero clearance for kitchen exhaust ducts., electrical circuit protection, and as a component in UL firestop designs for fire resistance rated floors, ceilings, and walls. The core fibers in FastWrap XL are manufactured using Morgan Thermal Ceramics patented Superwool® fiber which is alkaline -earth silicate wool with low biopersistenc andREVEWED FOR increased safety for installers. Fast Follow -Up Service Program to ens quality essential to this life -safety a %fvIPOMM> CLAI VAUDATIONI Commonly referred to test method CA Section Method for the Testing and Evaluation of Volatil from Indoor Sources Using Environmental Chambers Version 1.1, Feb 2010 Product Features EIVED CITY OF TUKWIL OCT 0920i4 • Thin and Lightweight at 1-1/2" (38mm) thick 6 pcf (96 kg/m3) density PERMIT CENTER • Contours easily to complex duct designs • Grease duct installation UL Listed with butt joints at all seams on both layers • Fully foil encapsulated for fast and clean installation • Contains 2192°F (1200°C) rated fibers • GreenGuard Microbial Resistance Listing • Good sound absorption • Compliant to IMC, NFPA 96, UMC, CMC 2. Applications • 1 and 2 hour enclosure and firestop system for kitchen exhaust ducts • Zero clearance to combustibles for kitchen exhaust ducts • 1 and 2 hour enclosure and firestop system for hazardous exhaust ducts, pressurization ducts, clothes dryer exhaust ducts, trash and linen chutes, and other fire rated HVAC ducts • 1 hour electrical circuit integrity protection • Engineered and tested solutions for fire protection of structural steel and storage vessels per ASTM E119, ISO 834, and UL1709 3. Specifications - Division 23 07 00 (or 15080) CSI Spec and AutoCAD available online, www.arcatcom/sd/clients/thermcer.html. FireMaster FastWrap XL is a flexible high temperature insulation rated to 2192 F (1200C) that is fully encapsulated in FSP facing. The duct enclosure system shall be listed by UL per ASTM E 2336 and ISO 6944 for 1-, 2- and 3-hour rating and zero clearance to ti ibustibles, and tested per ASTM E84 for a 9 L'COMPLIANC e he co fla plicatiorT.' ROVED de OCT 2 3 2014 R- ac in e/smoke rating less than 25/50. Insulation shall e a nominal thickness of 1-1/2 inches (38 mm) and sity of 6 Ibs/ft3 (96 kg/m3). Insulation shall have a alue of 7.3 at 75 F. Installation shall be in strict ordance to manufacturers published installation ructions, UL Listings, and shop drawings. Master FastDoor XL shall be used for duct access re specified or as required by code. www.morganthermalceramics.com H 05:2011 Page 1 of 8 14 Morgan ThermalCeramics FireMaster° FastWrap° XL 4. Physical Characteristics Product Unit Size Units/ Ctn. Wt./ Ctn. FastWrap XL Roll 1-1/2" x 24" x 25' 1 37.5 lbs. FastWrap XL Roll 1-1/2" x 48" x 25' 1 75 lbs. 5. Performance Specifications Reference Standard Standard No. Performance Grease Duct Enclosure System ASTM E2336 Pass Section 16.1 Non -Combustibility ASTM E136 Pass Section 16.2-Fire Resistance (wall) ASTM E119 Pass Section 16.3 - Durability Test ASTM C518 Pass Section 16.4 - Internal Fire Test ASTM E2336 Pass Section 16.5 - Fire Engulfment (duct) ASTM E814/E119 Pass ULC Grease Duct Test Protocol Pass Grease Duct Clearances UL 1978 Pass Air Ventilation Duct Enclosure ISO 6944 Pass Surface Burning Characteristics ASTM E84 <25/50 Thermal Resistance (R-value @ 75°F) ASTM C518 7.3 per layer Mold Growth ASTM C1338 ULE Validated ASTM D6329 GreenGuard Low VOCs CA Standard 01350 ULE Validated 6. Listings/Building Code Reports Listed Uses Agency Listing Layers Grease Duct Enclosure per ASTM E2336 and AC101 (2006, 2009, 2012 IMC, NFPA 96, UMC, CMC) UL G18 2 ICC-ES ESR 2213 Grease Duct Insulation per ULC Grease Duct Insulation Test Protocol ULC FRD 4, 7 2 Grease Duct Insulation (2003 IMC) OPL TC/BI 120-01 1 Through Penetration FireStop System per ASTM E814, UL 1479 UL See Figure 2 1 or 2 ULC 1- or 2-hour Ventilation Duct Enclosure per ISO 6944-1985 UL HNLJ.V1, 19, 29 1 ULC FRD 3, 5, 6, 18 3-hour Ventilation Duct Enclosure per ISO 6944-1985 UL HNLJ.V2 2 Electrical Circuit Protective System UL FHIT.5 2 7. Storage FastWrap XL must be stored in a dry warehouse environment on pallets. Pallets should not be stacked. 8. Installation FastWrap XL shall be installed by a qualified contractor in accordance with manufacturer's instructions and laboratory design listings. Materials and Equipment • FastWrap XL blanket • Aluminum foil tape • Glass filament reinforced tape (optional) • Carbon steel or stainless steel banding material, minimum 1/2" (13mm) wide, minimum 0.015" (0.4mm) thick, with steel banding clips • Hand banding tensioner and crimping tool • Minimum 12 gage (3mm) steel insulation pins; steel speed clips, minimum 1-1/2" (38mm) square or 1-1/2" (38mm) diameter, or equivalent sized cup -head pins; • Capacitor discharge stud gun • Morgan Thermal Ceramics FastDoor XL • An approved firestop sealant www.morganthermalceramics.com 05:2011 Page 2 of 8 11 Morgan ThermalCeramics FireMaster° FastWrap® XL General Cut edges of the blanket shall be taped with aluminum foil tape to prevent exposed edges of the insulation absorbing grease and moisture in the event of a compromised grease duct joint or condensation. Overlaps and/or tightly butted joints are used to block heat transfer in the event of duct deformation resulting from thermal expansion. Filament tape is suggested to hold the blanket in place until steel banding or pinning is installed to permanently secure the blanket. A. Installation on Grease Duct per ASTM E2336 (Figure 1) System requires two layers of insulation applied directly to the duct with tight butt joints at all seams on both layers. The first layer of insulation is cut to a length sufficient to wrap around the duct and provide a tight butt joint where the blanket ends meet. Adjacent blankets on the first layer are butted tightly together with longitudinal seams offset minimum 6" (150mm). The second layer of insulation is installed in the same method as the first layer, with seams between layers offset a minimum of 6" (150mm). Banding and/or pinning per Section D is used to permanently secure the insulation to the duct. B. Installation on HVAC Duct per ISO 6944 or Grease Duct per UL1978 (Figure 1) System requires one layer of insulation applied directly to the duct with 3" (75mm) overlaps at all seams. The insulation is cut to a length sufficient to wrap around the duct and provide a 3" (75mm) overlap where the blanket ends meet. Adjacent blankets are installed to provide a minimum overlap of 3" (75mm). Banding and/or pinning per Section D is used to permanently secure the insulation to the duct. C. 2 & 3 Sided Wrap Installation (Figure 4) When space does not allow for a complete wrap applied to the duct on all four sides, the FastWrap XL is approved for 2 or 3 sided installations with mechanical attachment to a rated concrete or CMU assembly. (See Figure 4 for installation details.) D. Mechanical Attachment Methods 1) Banding (Figure 1) - Minimum 1/2" (13mm) wide carbon steel or stainless steel banding, 0.015" (0.4mm) thick, is placed around the entire perimeter of the insulated duct on maximum 10-1/2" (270mm) centers and 1-1/2" (38mm) from each blanket edge or 1-1/2" (38mm) from each collar edge when using the butt joint and collar method. The banding is placed around the blanket and tightened to firmly hold the FastWrap XL in place against the duct, but not cause any cutting or damage to the blanket. 2) Pinning - Pinning on all sides of the duct may be used as an alternative to banding. For ducts wider than 24" (610mm) pinning is required on the bottom of horizontal runs, or on one side of vertical runs (in addition to steel banding). When applicable, 12 Gage (0.4mm) steel pins are installed on 12" (305mm) centers along the width of the duct and 10-1/2" (270mm) centers along the length of the duct. Pins that extend beyond the outer blanket layer shall be turned down or the excessive length cut off to prevent sharp edges. Shoot through pins (cup head pins) may be used in conjunction with steel banding to prevent blanket sag. E. Access Doors 1) FastDoorTM XL (Figure 3) - FastDoor XL is a UL Listed, liquid tight duct cover panel supplied complete with a single layer insulation cover per UL Listing HNKT G18. The FastDoor XL is installed per included installation instructions. No field welding is required. 2) Field Fabricated Access Doors - Each access door assembly has four threaded rods 1/4 inch (6mm) in diameter and 5" (127mm) in length, with one welded to each corner of the door opening. Hollow steel tubes, 4-1/2" (114mm) long are installed outside the access cover plate and over the threaded rods. Four 12 gage (3mm) and 4-1/2" (114mm) long steel insulation pins are welded to the access cover plate to allow for installation of the three layers of FastWrap XL. One layer of FastWrap XL is cut to approximately the same size as the access panel, and impaled over the insulation pins on the panel. A second layer of FastWrap XL is cut so as to overlap the first layer a minimum of 1-1/2" (38mm). It is essential that the first and second layer fit tightly against the surrounding wrap with no through openings. The third and outside layer should be cut to overlap the second insulation layer by a minimum of 1-1/2" (38mm). Minimum 1-1/2" (38mm) round or square insulation clips are installed on the insulation pins to secure the three layers of insulation to the access cover plate. All cut edges of the insulation shall be taped with minimum 3" (75mm) wide aluminum foil tape. Wing nuts and washers are installed on the four threaded rods, and tightened against the hollow steel tubes to seal the www.morganthermalceramics.com 05:2011 Page 3 of 8 Ili Morgan CThermalCeramics FireMaster® FastWrap® XL access cover plate to the duct. F. Through Penetration Firestop System (Figure 2) - When the duct penetrates a fire rated assembly an approved fire stop system must be employed. Figure 2 provides a complete list of UL / ULC firestop design listings which can be found in the Certifications Directory at wwwul.com for US systems and www ulc.ca for Canadian systems. Prior to installing any firestop system the surfaces of all openings and penetrating items must be clean and dry. The FastWrap XL core blanket (or mineral wool where allowed by the firestop design listing) must be compressed into the annular space. The packing material must be recessed a minimum depth from the surface of the concrete or gypsum assembly. The recessed opening must be filled with a minimum thickness of an approved firestop sealant. The packing material type and compression, minimum recess (typically 1/4" (6mm)), and approved firestop sealant and thickness (typically 1/4" (6mm)) shall be as specified in an approved UL / ULC firestop design listing. When there is not sufficient annular space around the duct to run the FastWrap XL enclosure system continuous through the fire rated assembly, the enclosure may terminate above and below the floor/ceiling assembly or on either side of a wall assembly as shown in Figure 2. When this method is used, the FastWrap XL must be mechanically attached on either side of the fire rated assembly using one of the attachment methods described in Section D, spaced a maximum of 1-1/2" (38mm) from the fire rated assembly. G. Support Hanger Systems 1) Grease ducts: Trapeze support hangers shall be spaced on maximum 60 in. (1500 mm) centers. Hanger rods or straps shall be anchored with steel drop in or wedge expansion type masonry anchors. No additional protection is required for hangers and supports meeting the requirements of the Table below. Hanger Cross Section Maximum Perimeter, in (mm) Trapeze Support (or equivalent Yleld Strength), in (mm) 38 in (10 mm) threaded rod 148(3759) 2(51)x2(51)x18(3)inan le 9 2) HVAC ducts: Trapeze support hangers shall be spaced on maximum 60 in. (1500 mm) centers. Hanger rods or straps shall be anchored with steel drop in or wedge ex- pansion type masonry anchors. No additional protection is required for hangers and supports meeting the requirements of the Table below. Hanger Cross Section Max. Perimeter, In (mm) Trapeze Support (or equiva- lent Yield Strength), In (mm) 1 in x 16 gage strap (25 mm x 1.5 gage strap) 100 (2540) 14 in (6 mm) threaded rod 50 (1270) 1:4 (38) x 1i4 (38) x 3116 (5) angle 38 in (10 mm) threaded rod 150 (3810) VA (38) x VA (38) x 316 (5) angle 12in(12.7mm) threaded rod 218 (5540) 2(51)x2(51)x14(6) angle 9. Maintenance and Repair No maintenance is required when installed in accordance with Morgan Thermal Ceramics (MTC) installation instructions. If damage is limited to the foil facing, aluminum foil tape can be used to repair the foil facing. If an area of blanket is found to be damaged the following procedure must be incorporated. If the damaged area is larger than 8" (203mm) x 8" (203mm) the entire wrap section must be removed and replaced according to MTC installation instructions. If the damaged area is small (less than 8" (203mm) x 8" (203mm)), the damaged area must be cut away and replaced with a new section 1" (25mm) larger in length and width than the cut out, such that the new section can be compressed tightly into the cut out area. All cut edges of the new section must be taped and sealed with aluminum foil tape. The new section must be held in place with either pinning or banding per MTC installation instructions. 10. Limitations Morgan Thermal Ceramics FireMaster FastWrap XL shall be installed in accordance with these installation instructions and appropriate laboratory design listings. The integrity of FastWrap XL systems is limited to the quality of the installation. * For personal protective equipment recommendations, please see MSDS. Thermal Ceramics, FireMaster, and FastWrap are trademarks of Morgan Crucible Company Plc. FireMaster products are manufactured by Morgan Thermal Ceramics and are distributed by authorized distributors. www.morganthermalceramics.com 05:2011 Page 4 of 8 11 Morgan CThermalCeramics FireMaster® FastWrap® XL 2-Hour and Zero Clearance Grease and HVAC Duct Enclosure System 112' 3 `)( 1 12' (38)1 Butt Joint / Butt Joint Typi TWO LAYER INSTALLATION OPTIONS (Grease Duct perASTM E23361 6' (155 3' (75) 11(2 (31) 21" (533)TYP. 12' 138) Telescope Wrap Option Butt Joint Option • 21"(533)TYP. 3" (75) 12"(38) Checkerboard Wrap Option SINGLE LAYER INSTALLATION OPTIONS (HVAC Duct or Grease Duct oer UL19781 FIGURE 1 1 Two Layers of FireMaster FastWrap XL forASTM E2336 Grease Duct Enclosures One Layer of FireMaster FastWrap XL for Air Ventilation Duct Enclosures 2 Steel banding minimum 1/2" (13) wide by 0.015" (0.4) thick. 3 Tight butt joints 4 Min. 3" (75) overlap on perimeter and between adjacent blankets 5 Optional 6" FireMaster FastWrap XL collar 6 Hangers - size dependent weight of assembly (see datasheet Section G) 7 Trapeze Supports - size dependent on weight of assembly (see datasheet Section G' 8 Steel Rectangular or Round Duct (gage and construction dependent on duct type) www.morganthermalceramics.com 05:2011 Page 5 of 8 U Morgan • ThermalCeramics FireMaster° FastWrap® XL Through Penetration Firestop Systems M .. raWkIWAV . Fastwrap XL continuous through rated wall assembly Fastwrap XL terminated on both sides of the rated wall assembly Fastwrap XL continuous through rated floor/ceiling assembly Fastwrap XL terminated at the top and bottom surface of the floor/ceiling assembly FIGURE 2 1 Rated Floor/ceiling or wall assembly 2 Duct 3 Two Layers of FireMaster FastWrap XL for Grease Duct Enclosures One Layer of FireMaster FastWrap XL for Air Ventilation Duct Enclosures 4 FireMaster FastWrap XL (packing material) 5 Approved through -penetration firestop sealant Firestop Designs PerASTM E814 / UL 1479 UL Listings ULC Listings C-AJ-1562 C-AJ-7004 FRD 3 C-AJ-7012 C-AJ-7014 FRD 4 C-AJ-7019 C-AJ-7021 FRD 5 C-AJ-7047 C-AJ-7095 FRD 6 C-AJ-7098 F-A-1093 FRD 7 F-A-3048 F-A-1094 FRD 18 F-C-7037 F-C-7036 W-L-7121 W-L-7009 W-J-7086 W-L-7145 www.morganthermalceramics.com 05:2011 Page 6 of 8 11 Morgan CThermalCeramics FireMaster® FastWrap® XL FASTDOOR XL Access Door Systems ASTM E 2336 Compliant Enclosure and Door System FIGURE 3 1 UL listed FastDoor XL access panel 2 All Thread Rods and wing nuts 3 Retainer Clips with threaded nut and wing bolts 4 Insulation layers as required by UL or ITS Listings 5 FastDoor XL; 1-1/2 inch thick single layer insulation UL 1978 Compliant Enclosure and Door System FastDoor XL1 Access Doors Sizes Available Opening Sizes Ordering Code 10" x 6" Door Opening 434-6970-034-99X1 12" x 8" Door Opening 434-6970-035-99X1 12" x 12" Door Opening 434-6970-036-99X1 16" x 12" Door Opening 434-6970-037-99X1 20" x 20" Door Opening 434-6970-038-99X1 www.morganthermalceramics.com 05:2011 Page 7 of 8 11 Morgan CThermalCeramics FireMaster® FastWrap® XL 2 and 3 Sided Wrap Detail for Attaching to Walls and/or Ceilings FIGURE 4 1 1 or 2 Hour Rated Concrete floor, ceiling, or wall 2 Insulation layers as required by UL and ULC Listings (see datasheet Section 6) 3 Concrete fastener system 4 3/16" (5) thick x 2" (50) -3" (75) wide bar stock perforated 12" (305) o.c. 5 8" (203) maximum Air Gap 6 Duct (independently supported as required by code) 7 Steel banding min. 1/2" (13) wide by 0.015" (0.4) thick. 8 Banding clip www.morganthermalceramics.com 05:2011 Page 8 of 8 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0193 DATE: 10/09/2014 PROJECT NAME: WENDY'S RESTAURANT SITE ADDRESS: 16300 WEST VALLEY HY X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: A I ,4dwc Building Division • Public Works ❑ fi1k C 1�13-rN Fire Prevention Structural ❑ Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 10/14/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/11/14 Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 METRO AIR INC Page 1 of 3 41.114 Washington 5tate Department of Lab©r & Industries METRO AIR INC Owner or tradesperson SCHEFFLER, MICHAEL ALLEN Principals SCHEFFLER, MICHAEL ALLEN, PRESIDENT HANLON, ASH T, VICE PRESIDENT Doing business as METRO AIR INC WA UBI No. 602 156 865 11021 128TH PL NE KIRKLAND, WA98033 425-889-8224 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties HeatingNent/Air-Conditioning and Refrig (HVAC/R) License no. METROAI995RC Effective — expiration 12/03/2001-12/03/2015 Bond CBIC Bond account no. SE0682 Received by L&I 12/03/2001 Insurance Ohio Cas Ins Co Policy no. BKO(12)53356859 Received by L&I 09/16/2014 $6,000.00 Effective date 11/15/2001 Expiration date Until Canceled $1,000,000.00 Effective date 11/15/2011 Expiration date 11/15/2015 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602156865&LIC=METROAI995RC&SAW= 10/27/2014